Sample records for routine coagulation tests

  1. Economic evaluation of a randomized controlled trial of pharmacist-supervized patient self-testing of warfarin therapy.

    PubMed

    Gallagher, J; Mc Carthy, S; Woods, N; Ryan, F; O' Shea, S; Byrne, S

    2015-02-01

    The increase in numbers of patients requiring oral anti-coagulation testing in outpatient clinics has focused attention on alternative flexible systems of anti-coagulation management. One option is pharmacist led patient self-testing (PST) of international normalised ratio (INR) levels. PST has demonstrated improvements in anti-coagulation control, but its cost-effectiveness is inconclusive. This study reports the first cost-effectiveness evaluation of a randomized controlled trial of an automated direct-to-patient expert system, enabling remote and effective management of patients on oral anti-coagulation therapy. We conducted an economic evaluation alongside a randomised controlled trial investigating a pharmacist led PST method. The primary outcome was to determine the cost effectiveness of PST in comparison with usual care (management in a hospital based anti-coagulation clinic). Long term anti-coagulation patients were recruited to a 6 month cross over study between PST and routine care in an anti-coagulation clinic. Economic evaluation was from the healthcare payer perspective. On a per patient basis over a 6 month period, PST resulted in an incremental cost of €59.08 in comparison with routine care. Patients achieved a significantly higher time in therapeutic range (TTR) during the PST arm in comparison with routine care, (72 ± 19.7% vs. 59 ± 13.5%). Overall cost of managing a patient through pharmacist supervised PST for a 6 month period is €226.45. Additional analysis of strategies from a societal perspective indicated that PST was the dominant strategy. Pharmacist led patient self-testing is a viable method of management. It provides significant increases in anti-coagulation control for a minimal increase in cost. © 2014 John Wiley & Sons Ltd.

  2. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.

    PubMed

    Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu

    2017-08-28

    The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all p<0.05). Although alkaline phosphatase, total bilirubin and hemoglobin reached statistical significance (p=0.009, 0.027 and 0.012, respectively), all had very low average bias which ranged from 0.01% to 2%. Potassium, total hemoglobin and percent deoxyhemoglobin were statistically significant for the neonatal capillary tube study (p=0.011, 0.033 and 0.041, respectively) but no biases greater than ±4% were identified for these parameters. All observed differences of these 48 laboratory tests were not clinically significant. The modern PTS investigated in this study is acceptable for reliable sample delivery for routine chemistry, hematology, coagulation and blood gas (in syringe and capillary tube) laboratory tests.

  3. [Comparison of thromboelastography and routine coagulation tests for evaluation of blood coagulation function in patients].

    PubMed

    Chen, Guan-Yi; Ou Yang, Xi-Lin; Wu, Jing-Hui; Wang, Li-Hua; Yang, Jin-Hua; Gu, Li-Nan; Lu, Zhu-Jie; Zhao, Xiao-Zi

    2015-04-01

    To investigate the correlation and consistency between thromboelastography(TEG) and routine coagulation tests, and to evaluate the value of the two methods in determining the blood coagulation of patients. The TEG, routine coagulation tests and platelet counts of 182 patients from the Intensive Care Unit(ICU) and Department of Gastroenterology in our hospital from January to September 2014 were performed and analyzed retrospectively for their correlation, Kappa identity test analysis and chi-square test, and the diagnostic sensitivity and specificity of both methods in the patients with bleeding were evaluated. The TEG R time and PT, R time and APTT showed a linear dependence (P<0.01). The relationship between the TEG K value, α-Angle, MA and Fibrinogen showed a linear dependence (P<0.001). And the relationship between the TEG K value, α-Angle, MA and the platelet count were in a linear dependent way (P<0.001). The Kappa values of the TEG R time with PT and APTT were 0.038 (P>0.05) and 0.061 (P>0.05), respectively. The chi-square test values of the TEG R time with PT and APTT were 35.309 (P<0.001) and 15.848 (P<0.001), respectively. The Fibrinogen and the TEG K value, α-Angle, MA value had statistical significance (P<0.001), with a Kappa value of 0.323, 0.288 and 0.427, respectively. The chi-square test values between Fibrinogen and the TEG K value, α-Angle, MA value were not statistically significant, with X2=1.091 (P=0.296), X2=1.361 (P=0.243), X2=0.108 (P=0.742). The Kappa values of the platelet count and the TEG K value, α-Angle, MA value were 0.379, 0.208 and 0.352, respectively, which were also statistically significant difference (P<0.001). The chi-square test values between the platelet count and the TEG K value, α-Angle, MA value showed a statistically significant difference (P<0.001), with X2=37.5, X2=37.23, X2=26.630. The diagnostic sensitivity of the two methods for the patients with bleeding was less than 50%. There was a significant correlation between some TEG parameters and routine coagulation tests, but the consistency is weak. Moreover, the diagnostic sensitivity of two methods in the patients with bleeding is low. It was concluded that the TEG cannot replace the conventional coagulation tests, and the preferable method remains uncertain which could reflect the risk of bleeding.

  4. Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory.

    PubMed

    Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja

    2018-02-23

    The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.

  5. Effect of the colloids gelatin and HES 130/0.4 on blood coagulation in cardiac surgery patients: a randomized controlled trial.

    PubMed

    Kimenai, D M; Bastianen, G W; Daane, C R; Megens-Bastiaanse, C M; van der Meer, N J M; Scohy, T V; Gerritse, B M

    2013-11-01

    The choice of the prime solution for cardiopulmonary bypass can play an important role in limiting the effect on blood coagulation, but it is still unclear what the effect of colloids on blood coagulation is. The aim of this study was to investigate the effect of synthetic colloids on blood loss and blood coagulation in patients after on-pump coronary artery bypass graft (CABG) procedures. Sixty elective, on-pump CABG patients were randomly assigned to receive the prime solutions lactated Ringer's solution combined with hydroxyethyl starch 130/0.4 (HES, 6% Volulyte, Fresenius Kabi Nederland BV, Zeist, the Netherlands) (HES group) or gelatin (Gelofusin(®), B Braun Melsung AG, Melsungen, Germany) (Gelo group). Blood loss was assessed using post-operative chest tube output; secondary endpoints were number of blood component transfusions, routine coagulation test values and rotation thromboelastometry values (Rotem(®) delta, Pentapharm GmbH, Munich, Germany). Total post-operative chest tube output was 500 ± 420 ml in the HES group versus 465 ± 390 ml in the Gelo group (p = 0.48). No significant differences were observed in any of the routine coagulation tests values, thromboelastometry parameters or number of blood component transfusions between the groups. In this randomized, controlled trial of adults after on-pump CABG procedures, there was no significant difference in blood loss or blood coagulation between the HES group and the Gelo group.

  6. Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays.

    PubMed

    Le Quellec, Sandra; Paris, Mickaël; Nougier, Christophe; Sobas, Frédéric; Rugeri, Lucia; Girard, Sandrine; Bordet, Jean-Claude; Négrier, Claude; Dargaud, Yesim

    2017-05-01

    Pneumatic tube system (PTS) in hospitals is commonly used for the transport of blood samples to clinical laboratories, as it is rapid and cost-effective. The aim was to compare the effects on haematology samples of a newly acquired ~2km-long PTS that links 2 hospitals with usual transport (non-pneumatic tube system, NPTS). Complete blood cell count, routine coagulation assays, platelet function tests (PFT) with light-transmission aggregometry and global coagulation assays including ROTEM® and thrombin generation assay (TGA) were performed on blood samples from 30 healthy volunteers and 9 healthy volunteers who agreed to take aspirin prior to blood sampling. The turnaround time was reduced by 31% (p<0.001) with the use of PTS. No statistically significant difference was observed for most routine haematology assays including PFT, and ROTEM® analysis. A statistically significant, but not clinically relevant, shortening of the APTT after sample transport by PTS was found (mean±SD: 30s±1.8 vs. 29.5s±2.1 for NPTS). D-dimer levels were 7.4% higher after transport through PTS but were not discordant. A statistically significant increase of thrombin generation was found in both platelet poor- and platelet rich- plasma samples after PTS transport compared to NPTS transport. PTS is suitable for the transport of samples prior to routine haematology assays including PFT, but should not be used for samples intended for thrombin generation measurement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  8. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  9. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  10. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  11. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  12. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion: A case report.

    PubMed

    Kim, Ji Hong; Kang, Min Ho; Seong, Mincheol; Cho, Heeyoon; Shin, Yong Un

    2018-04-01

    Non-arteritic anterior ischemic optic neuropathy (NAION) is characterized by sudden, painless visual loss and optic disc edema. NAION occurs mainly in the presence of cardiovascular disease and hypercoagulability, mainly in patients over 50 years of age. We experienced a case of NAION associated with central retinal vein occlusion (CRVO) in a young man with no underlying disease. A 46-year-old man was referred to our clinic following a sudden loss of vision in his right eye. The patient exhibited no underlying disease and reported no ongoing medication. Significant visual loss and visual disturbance of the right eye were observed. The pupil of the right eye was enlarged and an afferent pupillary defect was observed. On fundus examination, retinal hemorrhage was observed in the peripheral retina; macular edema was observed in optical coherence tomography analysis. However, optic disc edema was not evident. No abnormal findings were found in routine blood tests for hypercoagulability. After 3 days of steroid intravenous injection, macular edema disappeared and visual acuity was improved, but optic disc edema began to appear. One week later, optic disc edema was evident and visual acuity was significantly reduced; thus, the patient was diagnosed with NAION. In fluorescein angiography, peripheral retinal ischemia was observed, suggesting that CRVO was complicated. Blood tests, including analysis of coagulation factors, were performed again, showing that coagulation factors IX and XI were increased. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion. Systemic steroids were administered. One month later, optic disc edema and retinal hemorrhage gradually diminished and eventually disappeared; however, visual acuity did not recover. In young patients without underlying disease, cases of NAION require careful screening for coagulation disorders. Even if there is no abnormality in the test for routine coagulation status, it may be necessary to confirm a coagulation defect through an additional coagulation factor assay.

  13. Value of Routine Preoperative Tests for Coagulation Before Elective Cranial Surgery. Results of an Institutional Audit and a Nationwide Survey of Neurosurgical Centers in Pakistan.

    PubMed

    Akhunzada, Naveed Zaman; Tariq, Muhammad Bilal; Khan, Saad Akhtar; Sattar, Sidra; Tariq, Wajeeha; Shamim, Muhammad Shahzad; Dogar, Samie Asghar

    2018-05-03

    Routine preoperative blood testing has become a dogma. The general practice is to order preoperative workup as a knee-jerk response rather than individualize it for each patient. The fact that the bleeding brain tends to swell, which coupled with limited options for proximal control, packing, and overall hemostasis, leads to an overemphasis on the preoperative coagulation profile. This is a retrospective review of the medical records of patients admitted at Aga Khan University Hospital from January 2010 to December 2015 for an elective craniotomy. The hospital registry was used to identify files for review. Data were collected on a predefined proforma. A nationwide survey was performed, and 30 neurosurgery centers were contacted across Pakistan to confirm the practice of preoperative workup. The survey revealed that all centers had a similar practice of preoperative workup. This included complete blood count, serum electrolytes, and coagulation profile, including prothrombin time, activated partial thromboplastin time (aPTT), and international normalized ratio (INR). A total of 1800 files were reviewed. Nine (0.5%) patients were found to have deranged clotting profile without any predictive history of clotting derangement; 56% were male and 44% were female. Median age was 32 years with an interquartile range of 27 years. Median aPTT was (40.8 with 20.8 IQR). Median INR was (1.59 with 0.48 IQR). Median blood loss was (400 with 50 IQR). No significant association between coagulation profile (aPTT, INR) and blood loss was found (P = 0.85, r = -0.07). We conclude that patients without a history of coagulopathy and normal physical examination do not require routine coagulation screening before elective craniotomy. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Betrixaban: Impact on Routine and Specific Coagulation Assays-A Practical Laboratory Guide.

    PubMed

    Siriez, Romain; Evrard, Jonathan; Dogné, Jean-Michel; Pochet, Lionel; Gheldof, Damien; Chatelain, Bernard; Mullier, François; Douxfils, Jonathan

    2018-06-11

     Betrixaban is a novel direct oral factor Xa inhibitor approved by the Food and Drug Administration for prophylaxis of venous thromboembolism in adult patients hospitalized for an acute illness at risk for thromboembolic complications. Assessment of the anti-coagulant effect of betrixaban may be useful in some situations. Also, clinicians need to know how routine coagulation assays are influenced.  The aim of this study is to determine which coagulation assay(s) should be used to assess the impact of betrixaban on haemostasis and provide laboratory guidance for their interpretation.  Betrixaban was spiked at final concentrations ranging from 0 to 250 ng/mL in platelet-poor plasma. Different reagents from several manufacturers were tested and the impact of betrixaban on pro-thrombin time (PT), activated partial thromboplastin time (aPTT), dilute Russel viper venom time (dRVV-T), chromogenic anti-Xa assays, thrombin generation assay (TGA), and a large panel of haemostasis diagnostic tests has been assessed.  A concentration-dependent prolongation of aPTT, PT and dRVV-T is observed. The sensitivity mainly depends on the reagent. Chromogenic anti-Xa assays show high sensitivity depending on the reagent and/or the methodology. These assays applicable for other direct factor Xa inhibitors have to be adapted to obtain a relevant range of measurement. TGA may also be attractive to assess the anti-coagulant activity of betrixaban.  Adapted chromogenic anti-Xa assays are the most appropriate assays to estimate the concentration of betrixaban. Betrixaban significantly affects several haemostasis diagnostic tests and this needs to be taken into consideration when requesting and interpreting such tests. Schattauer GmbH Stuttgart.

  15. [Factor XIII-guided treatment algorithm reduces blood transfusion in burn surgery].

    PubMed

    Carneiro, João Miguel Gonçalves Valadares de Morais; Alves, Joana; Conde, Patrícia; Xambre, Fátima; Almeida, Emanuel; Marques, Céline; Luís, Mariana; Godinho, Ana Maria Mano Garção; Fernandez-Llimos, Fernando

    Major burn surgery causes large hemorrhage and coagulation dysfunction. Treatment algorithms guided by ROTEM ® and factor VIIa reduce the need for blood products, but there is no evidence regarding factor XIII. Factor XIII deficiency changes clot stability and decreases wound healing. This study evaluates the efficacy and safety of factor XIII correction and its repercussion on transfusion requirements in burn surgery. Randomized retrospective study with 40 patients undergoing surgery at the Burn Unit, allocated into Group A those with factor XIII assessment (n = 20), and Group B, those without assessment (n = 20). Erythrocyte transfusion was guided by a hemoglobin trigger of 10g.dL -1 and the other blood products by routine coagulation and ROTEM ® tests. Analysis of blood product consumption included units of erythrocytes, fresh frozen plasma, platelets, and fibrinogen. The coagulation biomarker analysis compared the pre- and post-operative values. Group A (with factor XIII study) and Group B had identical total body surface area burned. All patients in Group A had a preoperative factor XIII deficiency, whose correction significantly reduced units of erythrocyte concentrate transfusion (1.95 vs. 4.05, p = 0.001). Pre- and post-operative coagulation biomarkers were similar between groups, revealing that routine coagulation tests did not identify factor XIII deficiency. There were no recorded thromboembolic events. Correction of factor XIII deficiency in burn surgery proved to be safe and effective for reducing perioperative transfusion of erythrocyte units. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  16. Coagulation Testing in Acute Ischemic Stroke Patients Taking Non-Vitamin K Antagonist Oral Anticoagulants.

    PubMed

    Purrucker, Jan C; Haas, Kirsten; Rizos, Timolaos; Khan, Shujah; Poli, Sven; Kraft, Peter; Kleinschnitz, Christoph; Dziewas, Rainer; Binder, Andreas; Palm, Frederick; Jander, Sebastian; Soda, Hassan; Heuschmann, Peter U; Veltkamp, Roland

    2017-01-01

    In patients who present with acute ischemic stroke while on treatment with non-vitamin K antagonist oral anticoagulants (NOACs), coagulation testing is necessary to confirm the eligibility for thrombolytic therapy. We evaluated the current use of coagulation testing in routine clinical practice in patients who were on NOAC treatment at the time of acute ischemic stroke. Prospective multicenter observational RASUNOA registry (Registry of Acute Stroke Under New Oral Anticoagulants; February 2012-2015). Results of locally performed nonspecific (international normalized ratio, activated partial thromboplastin time, and thrombin time) and specific (antifactor Xa tests, hemoclot assay) coagulation tests were documented. The implications of test results for thrombolysis decision-making were explored. In the 290 patients enrolled, nonspecific coagulation tests were performed in ≥95% and specific coagulation tests in 26.9% of patients. Normal values of activated partial thromboplastin time and international normalized ratio did not reliably rule out peak drug levels at the time of the diagnostic tests (false-negative rates 11%-44% [95% confidence interval 1%-69%]). Twelve percent of patients apparently failed to take the prescribed NOAC prior to the acute event. Only 5.7% (9/159) of patients in the 4.5-hour time window received thrombolysis, and NOAC treatment was documented as main reason for not administering thrombolysis in 52.7% (79/150) of patients. NOAC treatment currently poses a significant barrier to thrombolysis in ischemic stroke. Because nonspecific coagulation test results within normal range have a high false-negative rate for detection of relevant drug concentrations, rapid drug-specific tests for thrombolysis decision-making should be established. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01850797. © 2016 American Heart Association, Inc.

  17. Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    PubMed

    Amukele, Timothy K; Sokoll, Lori J; Pepper, Daniel; Howard, Dana P; Street, Jeff

    2015-01-01

    Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  18. Diagnostic Error of a Patient with Combined Inherited Factor VII and Factor X Deficiency due to Accidental Ingestion of a Diphacinone Rodenticide.

    PubMed

    Li, Min; Jin, Yanhui; Wang, Mingshan; Xie, Yaosheng; Ding, Hongxiang

    2016-11-01

    To explore the characteristics of laboratory examination and confirm the diagnosis of a patient with combined inherited FVII and FX deficiency after he ingested diphacinone rodenticide accidentally. The coagulant parameter screening tests and coagulation factor activities were tested many times in the patient due to accidental ingestion of a diphacinone rodenticide. After the patient was treated for more than one year, gene analysis of correlated coagulation factors was analyzed in the patient and other family members by DNA direct sequencing. 106 persons were selected as controls from routine health examinations. After the patient was admitted to hospital, routine coagulation screening tests revealed the prolonged prothrombin time (PT) and activated partial thromboplastin time (APTT) and low levels of vitamin K-dependent coagulation factors (FII, FVII, FIX, FX) activity, which was 102.4 seconds, 88.5 seconds, 7%, 3%, 8%, and 2%, respectively. During more than one year of treatment, the value of PT and APTT still showed significantly prolonged activity and FVII and FX activity levels were about 5%. While FII and FIX activity levels were in the normal range after 12 weeks of treatment. Two homozygous mutations, g.11267C>T of F7 gene resulting in the substitution Arg277Cys and g.28139G>T of F10 gene leading to the substitution Val384Phe, were identified in the patient. The patient's parents and sister was heterozygous for Arg277Cys and Val384Phe mutations. FVII and FX antigen levels in the patient were 7% and 30%, respectively. There were many similarities in the characteristics of laboratory examination between combined inherited FVII and FX deficiency and acquired vitamin K deficiency. The best way to identify them was gene analysis.

  19. Administration of tissue plasminogen activator without coagulation results in a Chinese population.

    PubMed

    Qin, Xiaoming; Zhao, Songyao; Yin, Liujie; Dou, Hailing; Chen, Jie; Wang, Yifan; Li, Mingzhe; Chen, Ruifang; Fu, Jing; Liu, Wei; Liu, Xin; Yang, Gaiqing; Wang, Runqing; Jia, Xinzhou; Bu, Shufang; Ma, Dongpu; Wang, Baoyu; Li, Shize

    2018-03-01

    Routine coagulation test before intravenous tissue plasminogen activator (tPA) use increases the door to needle time (DNT). We sought to evaluate the safety of tPA use without coagulation results and its impact on prognosis. In our stroke registry, tPA was delivered with coagulation results from December 2015 to April 2016 and without coagulation results from May 2016 to December 2016. Differences of demographics, clinical characteristic, and prognosis between these two groups were analyzed. In addition, logistic regression analysis was conducted to identify predictors for DNT of over 60 min. A total of 201 stroke patients were included in the final analysis. Of these, 81 patients received tPA with coagulation results and 120 patients without coagulation results. Only one (0.8%) patient with abnormal coagulation results met the exclusion criteria of tPA use in patients without coagulation results. The difference of DNT between groups with (mean, 61.7 min) and without (mean, 41.9 min) coagulation results was significant (P = 0.00). The group without coagulation results had a higher rate of favorable 90-day outcome (74.2 vs 70.4%) and lower rates of symptomatic intracranial hemorrhage/nonintracranial hemorrhage (4.9 and 22.2% vs 1.7 and 19.2%) than the group with coagulation results did; these differences were not statistically significant. In multivariate analysis, only tPA use with coagulation results was the predictor for DNT of over 60 min (P = 0.0030, OR = 2.44, 95% CI 1.28-4.65). The present study suggests that tPA could be delivered safely without coagulation results in patients without suspected coagulopathy, and avoiding coagulation tests reduces significantly the DNT interval.

  20. Coagulopathy induced by acidosis, hypothermia and hypocalcaemia in severe bleeding.

    PubMed

    De Robertis, E; Kozek-Langenecker, S A; Tufano, R; Romano, G M; Piazza, O; Zito Marinosci, G

    2015-01-01

    Acidosis, hypothermia and hypocalcaemia are determinants for morbidity and mortality during massive hemorrhages. However, precise pathological mechanisms of these environmental factors and their potential additive or synergistic anticoagulant and/or antiplatelet effects are not fully elucidated and are at least in part controversial. Best available evidences from experimental trials indicate that acidosis and hypothermia progressively impair platelet aggregability and clot formation. Considering the cell-based model of coagulation physiology, hypothermia predominantly prolongs the initiation phase, while acidosis prolongs the propagation phase of thrombin generation. Acidosis increases fibrinogen breakdown while hypothermia impairs its synthesis. Acidosis and hypothermia have additive effects. The effect of hypocalcaemia on coagulopathy is less investigated but it appears that below the cut-off of 0.9 mmol/L, several enzymatic steps in the plasmatic coagulation system are blocked while above that cut-off effects remain without clinical sequalae. The impact of environmental factor on hemostasis is underestimated in clinical practice due to our current practice of using routine coagulation laboratory tests such as partial thromboplastin time or prothrombin time, which are performed at standardized test temperature, after pH correction, and upon recalcification. Temperature-adjustments are feasible in viscoelastic point-of-care tests such as thrombelastography and thromboelastometry which may permit quantification of hypothermia-induced coagulopathy. Rewarming hypothermic bleeding patients is highly recommended because it improves patient outcome. Despite the absence of high-quality evidence, calcium supplementation is clinical routine in bleeding management. Buffer administration may not reverse acidosis-induced coagulopathy but may be essential for the efficacy of coagulation factor concentrates such as recombinant activated factor VII.

  1. Effects of saline or albumin resuscitation on standard coagulation tests.

    PubMed

    Bellomo, Rinaldo; Morimatsu, Hiroshi; Presneill, Jeff; French, Craig; Cole, Louise; Story, David; Uchino, Shigehiko; Naka, Toshio; Finfer, Simon; Cooper, D James; Myburgh, John

    2009-12-01

    To explore whether fluid resuscitation with normal saline or 4% albumin is associated with differential changes in routine clinical coagulation tests. Substudy from a large double-blind randomised controlled trial, the SAFE (Saline versus Albumin Fluid Evaluation) study. Three general intensive care units. Cohort of 687 critically ill patients. We randomly allocated patients to receive either 4% human albumin or normal saline for fluid resuscitation, and collected demographic and haematological data. Albumin was administered to 338 patients and saline to 349. At baseline, the two groups had similar mean activated partial thromboplastin time (APTT) of 37.2 s (albumin) v 39.1 s (saline); mean international normalised ratio (INR) of 1.38 v 1.34, and mean platelet count of 244 x 10(9)/L v 249 x 10(9)/L. After randomisation, during the first day of treatment, the APTT in the albumin group was prolonged by a mean of 2.7 s, but shortened slightly by a mean of -0.9 s in the saline group. The INR did not change in either group, while the platelet count decreased transiently in both groups. Using multivariate analysis of covariance to account for baseline coagulation status, albumin fluid resuscitation (P = 0.01) and a greater overall volume of resuscitation (P = 0.03) were independently associated with prolongation of APTT during the first day. Administration of albumin or of larger fluid volumes is associated with a prolongation of APTT. In ICU patients, the choice and amount of resuscitation fluid may affect a routinely used coagulation test.

  2. Overuse of preoperative laboratory coagulation testing and ABO blood typing: a French national study.

    PubMed

    Beloeil, H; Ruchard, D; Drewniak, N; Molliex, S

    2017-12-01

    Following publication of guidelines on routine preoperative tests, the French Society of Anaesthesiology and Intensive Care (SFAR), in association with French national public health insurance, conducted a survey to evaluate adherence to guidelines and the economic consequences. Using the French Hospital Discharge Database and National Health Insurance Information system, tests performed during the 30 days before surgery were analysed for two situations: (1) standard laboratory coagulation tests and ABO blood typing in children able to walk and scheduled for tonsillectomy/adenoidectomy; and (2) ABO blood typing in adults before laparoscopic cholecystectomy, thyroidectomy, lumbar discectomy or breast surgery. Guidelines do not recommend any preoperative tests in these settings. Between 2013 and 2015, a coagulation test was performed in 49% of the 241 017 children who underwent tonsillectomy and 39% of the 133 790 children who underwent adenoidectomy. A similar pattern was observed for ABO blood typing although re-operation rates for bleeding on the first postoperative day were very low (0.12-0.31% for tonsillectomy and 0.01-0.02% for adenoidectomy). Between 2012 and 2015, ABO blood typing was performed in 32-45% of the 1 114 082 patients who underwent one of the four selected procedures. The transfusion rate was very low (0.02-0.31%). The mean cost for the four procedures over the 4 yr period was €5 310 000 (sd €325 000). Standard laboratory coagulation tests and ABO blood typing are still routinely prescribed before surgery and anaesthesia despite current guidelines. This over-prescription represents a high and unnecessary cost, and should therefore be addressed. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  3. Separation of whole blood into plasma and red cells by using a hollow-fibre filtration system.

    PubMed

    Hornsey, V S; McColl, K; Drummond, O; Prowse, C V

    2005-08-01

    The aim of this study was to assess the separation of whole blood into red cells and plasma by using the Sangofer device, which is a gravity-fed, hollow-fibre system. The components would then be compared with those produced by the use of more elaborate technical equipment. Ten whole-blood units were leucoreduced by using a WBF2 filter and immediately separated into red cells and plasma by using the Sangofer blood-separation device. Red cells were stored in additive solution and tested on days 1 and 42. The plasma was assayed for levels of various coagulation factors and for markers of both coagulation and complement activation. The red-cell parameters were similar to those obtained when routine centrifugation methods were used. The filter did not cause haemolysis. Levels of plasma factor VIII and factor XI were lower than those seen in routinely produced leucoreduced plasma units but there was no evidence of activation of the coagulation and complement systems. The Sangofer device is simple and straightforward to use and eliminates the need for both centrifugation and automated separation steps during the processing of whole blood into red cells and plasma components. Minor changes are required to make the procedure easier to incorporate into routine use.

  4. [Point of Care 2.0: Coagulation Monitoring Using Rotem® Sigma and Teg® 6S].

    PubMed

    Weber, Christian Friedrich; Zacharowski, Kai

    2018-06-01

    New-generation methods for point of care based coagulation monitoring enable fully automated viscoelastic analyses for the assessment of particular parts of hemostasis. Contrary to the measuring techniques of former models, the viscoelastic ROTEM ® sigma and TEG ® 6s analyses are performed in single-use test cartridges without time- and personnel-intensive pre-analytical procedures. This review highlights methodical strengths and limitations of the devices and meets concerns associated with their integration in routine clinical practice. Georg Thieme Verlag KG Stuttgart · New York.

  5. Congenital combined deficiency of coagulation factors: a study of seven patients.

    PubMed

    Naderi, Majid; Tabibian, Shadi; Hosseini, Maryam Sadat; Alizadeh, Shaban; Hosseini, Soudabeh; Shamsizadeh, Morteza; Dorgalaleh, Akbar

    2015-01-01

    Combined deficiency of coagulation factors is considered as an extremely rare bleeding disorder (RBD) inherited in an autosomal recessive pattern. This disorder is more likely to occur in regions with a high rate of consanguineous marriages or in restricted communities. Sistan and Baluchistan, a province in southeast of Iran with a high rate of consanguinity, is a clear model of such regions with a very high prevalence of recessively inherited disorders. The aim of this study was to report the frequency of combined factor deficiency in this province. This descriptive study was conducted on 358 patients with RBD. Demographic information and medical history of each patient were recorded, and the patients were examined by a physician. Routine screening tests were carried out for all patients, and further coagulation tests including coagulation factor activity and antigen assays were subsequently performed for all suspected patients. Among 358 patients, four were found to be affected with combined factor (F)V and FVIII deficiency (F5F8D). In addition, one patient with combined deficiency of FVII-FXIII, one with combined FVII-FX and one with combined FVIII-FIX deficiency were identified. In Sistan and Baluchistan Province, coinheritance of recessively inherited disorders like combined coagulation factor deficiencies was surprisingly higher than expected.

  6. Monitoring and treatment of coagulation abnormalities in burn patients. an international survey on current practices

    PubMed Central

    Lavrentieva, A.; Depetris, N.; Kaimakamis, E.; Berardino, M.; Stella, M.

    2016-01-01

    Summary The magnitude of coagulation abnormalities, and the definition and treatment of coagulopathy in burn patients are inadequately understood and continue to be discussed in the literature. We aimed to analyse physicians’ views on monitoring and treating coagulation abnormalities in burn patients. A total of 350 questionnaires were distributed electronically to burn ICU physicians. Participation was voluntary and anonymous. Responses were analysed electronically and comparisons were made according to the region of the ICU or the specialty of the physician. Of the 350 questionnaires distributed, 55 (15.7%) were returned. The majority of burn specialists consider sepsis-induced coagulopathy to be the most frequent coagulopathy in burn patients, and 74.5% declare that they do not use any specific definition/scoring system in their department to detect coagulopathy. The majority of specialists (70.8%) use standard coagulation tests. The most frequent indications for plasma transfusion are massive bleeding (32.8%) and Disseminated Intravascular Coagulation syndrome treatment (20%). The main specific factors reported in our study are cryoprecipitate (23.2%) and fibrinogen concentrate (18.9%). 21.1% of respondents state that they do not use any specific coagulation factor substitution in burn patients. Specific coagulation factor substitution is not a routine practice. The low response rate precludes the generalization of our results. PMID:28149244

  7. Is viscoelastic coagulation monitoring with ROTEM or TEG validated?

    PubMed

    Solomon, Cristina; Asmis, Lars M; Spahn, Donat R

    2016-10-01

    Recent years have seen increasing worldwide interest in the use of viscoelastic coagulation monitoring tests, performed using devices such as ROTEM and TEG. The use of such tests to guide haemostatic therapy may help reduce transfusion of allogeneic blood products in bleeding patients and is supported in European guidelines for managing trauma and severe perioperative bleeding. In addition, viscoelastic tests form the basis of numerous published treatment algorithms. However, some publications have stated that viscoelastic tests are not validated. A specific definition of the term validation is lacking and regulatory requirements of the US Food and Drug Administration (FDA) and European Medicines Agency (EMA) have been fulfilled by ROTEM and TEG assays. Viscoelastic tests have been used in pivotal clinical trials, and they are approved for use in most of the world's countries. Provided that locally approved indications are adhered to, the regulatory framework for clinicians to use viscoelastic tests in routine clinical practice is in place.

  8. Rivaroxaban and apixaban in orthopaedics: is there a difference in their plasma concentrations and anticoagulant effects?

    PubMed Central

    Freyburger, Geneviève; Macouillard, Gérard; Khennoufa, Karim; Labrouche, Sylvie; Molimard, Mathieu; Sztark, François

    2015-01-01

    The aim of this study was to improve knowledge of what happens in the coagulation of orthopaedic patients under rivaroxaban and apixaban, in order to finalize and cross-validate effective measurement methods and to provide arguments for helping to reference one or the other drug in our central pharmacy. One hundred and two patients undergoing total hip or knee replacement were included. Half of them received rivaroxaban and the other half received apixaban. Blood samples (n = 244 with each drug) were taken at Cmax preoperatively and twice a week, apart from the day of the patient's discharge, when Ctrough concentration was targeted. Routine coagulation parameters, and functional and liquid chromatography tandem mass spectrometry assays for measurement of circulating concentrations were studied. The LC-MS/MS assay and the functional assays carried out in patients under routine conditions were highly correlated, apart from low concentrations (<30 ng/ml), which were affected by the variable individual potential to inhibit the exogenous bovine Xa used in the functional assays. After 1 week of treatment, the drugs differed: Cmax and Ctrough were closer when apixaban was taken twice daily (83 ± 39 and 58 ± 17 ng/ml) than with rivaroxaban taken once a day (113 ± 67 and 13 ± 20 ng/ml). Rivaroxaban had a greater influence on routine coagulation tests and reduced the maximum thrombin concentration more efficiently, as assessed by the thrombin generation test. Although rivaroxaban and apixaban present apparently similar constant rates, they exhibit significant differences in their concentrations and anticoagulant effects when studied ex vivo in orthopedic patients. PMID:26258673

  9. Analysis of rhG-CSF-effects on platelets by in vitro bleeding test and transcranial Doppler ultrasound examination.

    PubMed

    Söhngen, D; Wienen, S; Siebler, M; Boogen, C; Scheid, C; Schulz, A; Kobbe, G; Diehl, V; Heyll, A

    1998-12-01

    Experimental evidence suggests a stimulatory effect of recombinant human granulocyte colony-stimulating factor (rhG-CSF) on both platelets and coagulation. RhG-CSF is increasingly used to stimulate healthy volunteer donors for blood stem cell mobilization. We therefore assessed 25 healthy donors receiving rhG-CSF for changes in in vitro bleeding test (IVBT), coagulation parameters and cerebral microembolism by transcranial Doppler (TCD) ultrasound. A significant shortening of IVBT was found on day 4 of rhG-CSF administration together with increased levels of fibrinogen and factor VIII and reduced activities of protein C and protein S. Although these changes are quite small it is possible that they may lead to a hypercoagulable state especially in donors with other risk factors for thromboembolism. However, TCD examination failed to detect any signs of microembolism. We therefore conclude that rhG-CSF leads to significant changes in coagulation parameters, but has no effect on TCD detectable microembolism as a stroke risk factor. However donors receiving rhG-CSF should be examined carefully to detect pre-existing changes in the coagulation system and we would like to suggest a routine thrombophilia screen.

  10. Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2013-04-01

    Sometimes in-vitro diagnostic devices (e.g. blood collection tubes) are not validated before use or when the producer's brand is changed. The aim of this study was to validate five brands of sodium citrate vacuum tubes. Blood specimens from 50 volunteers were collected in five different tube brands (I: Venosafe, II: VACUETTE, III: BD Vacutainer, IV: LABOR IMPORT and V: S-Monovette). Routine coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen (FIB)] were performed on ACL TOP instrument using HemosIL reagents. The significance of the differences between samples was assessed by paired Student's t-test, set at P < 0.005. Significant differences were observed for: PT when comparing I vs. II, I vs. III, I vs. V, II vs. III, II vs. IV, II vs. V, III vs. IV, III vs. V and IV vs. V; aPTT when comparing I vs. II, I vs. III, I vs. IV, II vs. IV, III vs. IV and IV vs. V. No differences were observed among brands for FIB determination. We suggest that every laboratory management should both standardize the procedures and frequently evaluate the quality of in-vitro diagnostic devices.

  11. Thromboelastographic evaluation of dogs with congenital portosystemic shunts.

    PubMed

    Kelley, D; Lester, C; DeLaforcade, A; Webster, C R L

    2013-01-01

    On plasma-based assays, dogs with congenital portosystemic shunts (CPSS) have changes in serum concentrations of both pro- and anticoagulant proteins, but how these abnormalities affect whole blood coagulation assays (eg, thromboelastography) are unknown. To conduct kaolin-activated thromboelastography (TEG) analysis in dogs with CPSS and to compare TEG coagulation status with clinical presentation, routine serum biochemistry, and plasma-based coagulation tests. Twenty-one client-owned dogs with CPSS confirmed by ultrasound examination or nuclear scintigraphy. In a prospective study, signalment, clinical presentation, TEG analysis, CBC, serum biochemistry, and hemostatic tests (platelet count, prothrombin time [PT], activated partial thromboplastin time [aPTT], quantitative fibrinogen, antithrombin [AT] activity, protein C [PC] activity, d-dimers, and factor VIII activity) were analyzed in dogs with CPSS. Dogs with CPSS had significantly shorter K values and increased angle, maximum amplitude (MA), and G values compared with the reference population. On plasma-based coagulation testing, dogs with CPSS had significantly prolonged PT, lower platelet counts, lower AT and PC activities, and increased d-dimers and factor VIII activity. Evaluation of G value defined 9/21 dogs with CPSS as hypercoagulable. These dogs were more likely to have hepatic encephalopathy (HE) than CPSS dogs that had normal coagulation. TEG analysis detected hemostatic abnormalities consistent with a hypercoagulable state in some dogs with CPSS. The presence of a hypercoagulable state was 40 times more likely in dogs with symptomatic HE. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  12. Effect of Centrifuge Temperature on Routine Coagulation Tests.

    PubMed

    Yazar, Hayrullah; Özdemir, Fatma; Köse, Elif

    2018-01-01

    This study investigated the effects of cooled and standard centrifuges on the results of coagulation tests to examine the effects of centrifugation temperature. Equal-volume blood samples from each patient were collected at the same time intervals and subjected to standard (25°C) and cooled centrifugation (2-4°C). Subsequently, the prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, and D-dimer values were determined in runs with the same lot numbers in the same coagulation device using the Dia-PT R (PT and INR), Dia-PTT-liquid (aPTT), Dia-FIB (fibrinogen), and Dia-D-dimer kits, respectively. The study enrolled 771 participants. The PT was significantly (p < 0.018) higher in participants on anticoagulant therapy. The respective median values of the test parameters determined using the standard and cooled centrifuges were as follows: PT 10.30 versus 10.50 s; PT (INR) 1.04 versus 1.09 s; APTT 28.90 versus 29.40 s; fibrinogen 321.5 versus 322.1 mg/dL; and D-dimer 179.5 versus 168.7 µg FEU/mL. There were significant differences (p < 0.001) in the parameters between the values obtained with the standard and cooled centrifuges. Centrifuge temperature can have a significant effect on the results of coagulation tests. However, broad and specific disease-based studies are needed. © 2018 S. Karger AG, Basel.

  13. Reference values of clinical chemistry and hematology parameters in rhesus monkeys (Macaca mulatta).

    PubMed

    Chen, Younan; Qin, Shengfang; Ding, Yang; Wei, Lingling; Zhang, Jie; Li, Hongxia; Bu, Hong; Lu, Yanrong; Cheng, Jingqiu

    2009-01-01

    Rhesus monkey models are valuable to the studies of human biology. Reference values for clinical chemistry and hematology parameters of rhesus monkeys are required for proper data interpretation. Whole blood was collected from 36 healthy Chinese rhesus monkeys (Macaca mulatta) of either sex, 3 to 5 yr old. Routine chemistry and hematology parameters, and some special coagulation parameters including thromboelastograph and activities of coagulation factors were tested. We presented here the baseline values of clinical chemistry and hematology parameters in normal Chinese rhesus monkeys. These data may provide valuable information for veterinarians and investigators using rhesus monkeys in experimental studies.

  14. Current limitations of the assessment of haemostasis in adult extracorporeal membrane oxygenation patients and the role of point-of-care testing.

    PubMed

    Venkatesh, K; Nair, P S; Hoechter, D J; Buscher, H

    2016-11-01

    Haemostatic perturbations are commonly seen in extracorporeal membrane oxygenation (ECMO) patients and remain a clinical challenge, contributing significantly to morbidity and mortality. The approach to anticoagulation monitoring and the management of bleeding varies considerably across ECMO centres. Routine laboratory tests have their limitations in terms of turnaround time and specificity of information provided. Newer point-of-care testing (POCT) for coagulation may overcome these issues, as it provides information about the entire coagulation pathway from clot initiation to lysis. It is also possible to obtain qualitative information on platelet function from these tests. Furthermore, the ability to incorporate these results into a goal-directed algorithm to manage bleeding with targeted transfusion strategies appears particularly attractive and cost effective. Further studies are required to evaluate the utility of POCT to optimise bleeding and anticoagulation management in these complex patients.

  15. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    PubMed

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  16. Influence of centrifuge brake on residual platelet count and routine coagulation tests in citrated plasma.

    PubMed

    Daves, Massimo; Giacomuzzi, Katia; Tagnin, Enrico; Jani, Erika; Adcock Funk, Dorothy M; Favaloro, Emmanuel J; Lippi, Giuseppe

    2014-04-01

    Sample centrifugation is an essential step in the coagulation laboratory, as clotting tests are typically performed on citrated platelet (PLT) poor plasma (PPP). Nevertheless, no clear indication has been provided as to whether centrifugation of specimens should be performed with the centrifuge brake set to on or off. Fifty consecutive sodium citrate anticoagulated samples were collected and divided into two aliquots. The former was centrifuged as for Clinical Laboratory Standards Institute (CLSI) guidelines with the centrifuge brake set to on, whereas the latter was centrifuged again as for CLSI guidelines, but with the brake set to off. In the PPP of all samples, a PLT count was performed, followed by the analysis of activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen (FBG). The PLT count after samples centrifugation was substantially reduced, either with centrifuge brake set to on or off (5 ± 1 versus 3 ± 1 × 10/l; P = 0.009). The frequency of samples exceeding a PLT count less than 10 × 10/l was nearly double in samples centrifuged with the brake on than in those with the brake off (14 versus 8%; P < 0.01). Although no significant difference was found for APTT values, PT was slightly prolonged using the centrifuge brake set to on (mean bias 0.2 s; P < 0.001). FBG values were also significantly higher using the centrifuge brake set to on (mean bias 0.29 g/l; P < 0.001). The results of this study indicate that sample centrifugation for routine coagulation testing should be preferably performed with the centrifuge brake set to off for providing a better quality specimen.

  17. Validation of a New Small-Volume Sodium Citrate Collection Tube for Coagulation Testing in Critically Ill Patients with Coagulopathy.

    PubMed

    Adam, Elisabeth H; Zacharowski, Kai; Hintereder, Gudrun; Raimann, Florian; Meybohm, Patrick

    2018-06-01

    Blood loss due to phlebotomy leads to hospital-acquired anemia and more frequent blood transfusions that may be associated with increased risk of morbidity and mortality in critically ill patients. Multiple blood conservation strategies have been proposed in the context of patient blood management to minimize blood loss. Here, we evaluated a new small-volume sodium citrate collection tube for coagulation testing in critically ill patients. In 46 critically adult ill patients admitted to an interdisciplinary intensive care unit, we prospectively compared small-volume (1.8 mL) sodium citrate tubes with the conventional (3 mL) sodium citrate tubes. The main inclusion criterium was a proven coagulopathy (Quick < 60% and/or aPTT > 40 second) due to anticoagulation therapy or perioperative coagulopathy. In total, 92 coagulation analyses were obtained. Linear correlation analysis detected a positive relationship for 7 coagulation parameters (Prothrombin Time, r = 0.987; INR, r = 0.985; activated Partial Thromboplastin Time, r = 0.967; Thrombin Clotting Time, r = 0.969; Fibrinogen, r = 0.986; Antithrombin, r = 0.988; DDimer, r = 0.969). Bland-Altman analyses revealed an absolute mean of differences of almost zero. Ninety-five percent of data were within two standard deviations of the mean difference suggesting interchangeability. As systematic deviations between measured parameters of the two tubes were very unlikely, test results of small-volume (1.8 mL) sodium citrate tubes were equal to conventional (3 mL) sodium citrate tubes and can be considered interchangeable. Small-volume sodium citrate tubes reduced unnecessary diagnostic-related blood loss by about 40% and, therefore, should be the new standard of care for routine coagulation analysis in critically ill patients.

  18. On the value of routine prothrombin time screening in elective neurosurgical procedures.

    PubMed

    Dützmann, Stephan; Gessler, Florian; Marquardt, Gerhard; Seifert, Volker; Senft, Christian

    2012-11-01

    The authors performed a study to evaluate whether preoperative assessment of prothrombin time (PT) is mandatory in patients undergoing routinely planned neurosurgical procedures. The charts of all patients admitted to general wards of the authors' department for routinely planned surgery (excluding trauma and ICU patients) between 2006 and 2010 were retrospectively reviewed. The authors assessed preoperative PT and the clinical courses of all patients, with special consideration for patients receiving coagulation factor substitution. All cases involving hemorrhagic complications were analyzed in detail with regard to pre- and postoperative PT abnormalities. Prothrombin time was expressed as the international normalized ratio, and values greater than 1.28 were regarded as elevated. Clinical courses and PT values of 4310 patients were reviewed. Of these, 33 patients (0.7%) suffered hemorrhagic complications requiring repeat surgery. Thirty-one patients (94%) had a normal PT before the initial operation, while 2 patients had slightly elevated PT values of 1.33 and 1.65, which were anticipated based on the patient's history. In the latter 2 cases, surgery was performed without prior correction of PT. Preoperatively, PT was elevated in 78 patients (1.8%). In 73 (93.6%) of the 78 patients, the PT elevation was expected and explained by each patient's medical history. In only 5 (0.1%) of 4310 patients did we find an unexpected PT elevation (mean 1.53, range 1.37-1.74). All 5 patients underwent surgery without complications, while 2 had received coagulation factor substitution preoperatively, as requested by the surgeon, because of an estimated risk of bleeding complications. None of the 5 patients received coagulation factor substitution postoperatively, and later detailed laboratory studies ruled out single coagulation factor deficiencies. There was no statistically significant association between preoperatively elevated PT levels and the occurrence of hemorrhagic complications (p = 0.12). Before the second procedure but not before the initial operation, 4 (12%) of the 33 patients had elevated PT. The findings suggest that the value of preoperative PT testing is limited in patients in whom a normal history can be ascertained. Close postoperative PT control is necessary in every neurosurgical patient, and better tests need to be developed to identify patients who are prone to hemorrhagic complications.

  19. Influence of apixaban on commonly used coagulation assays: results from the Belgian national External Quality Assessment Scheme.

    PubMed

    Van Blerk, M; Bailleul, E; Chatelain, B; Demulder, A; Devreese, K; Douxfils, J; Jacquemin, M; Jochmans, K; Mullier, F; Wijns, W; China, B; Vernelen, K; Soumali, M R

    2017-08-01

    The Belgian national External Quality Assessment Scheme performed a survey to assess the effect of the direct oral anticoagulant apixaban on the coagulation assays prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen and antithrombin as performed with a large number of reagent/instrument combinations. Four lyophilized plasma samples spiked with apixaban (0, 41, 94 and 225 ng/mL) were sent to the 195 Belgian and Luxembourg clinical laboratories performing coagulation testing. PT and aPTT were barely influenced at the concentrations tested. At 225 ng/mL apixaban, PT and aPTT clotting times were only 1.15 times longer than at 0 ng/mL. Among PT reagents, RecombiPlasTin 2G ® showed a slightly higher sensitivity with 225 ng/mL apixaban prolonging the PT clotting time 1.3-fold. Among aPTT reagents, there was no appreciable difference in sensitivity. Fibrinogen results were unaffected by the presence of apixaban, but antithrombin activity was considerably overestimated when measured with a FXa-based assay. At 225 ng/mL apixaban, the median percentage increase in antithrombin level was 31% when measured with the Liquid Antithrombin ® reagent and 44% with the Innovance Antithrombin ® reagent. Our data provide clinical laboratories with useful information on the impact of apixaban on their routine coagulation assays. © 2017 John Wiley & Sons Ltd.

  20. Point-of-Care Coagulation Monitoring in Trauma Patients.

    PubMed

    Stein, Philipp; Kaserer, Alexander; Spahn, Gabriela H; Spahn, Donat R

    2017-06-01

    Trauma remains one of the major causes of death and disability all over the world. Uncontrolled blood loss and trauma-induced coagulopathy represent preventable causes of trauma-related morbidity and mortality. Treatment may consist of allogeneic blood product transfusion at a fixed ratio or in an individualized goal-directed way based on point-of-care (POC) and routine laboratory measurements. Viscoelastic POC measurement of the developing clot in whole blood and POC platelet function testing allow rapid and tailored coagulation and transfusion treatment based on goal-directed, factor concentrate-based algorithms. The first studies have been published showing that this concept reduces the need for allogeneic blood transfusion and improves outcome. This review highlights the concept of goal-directed POC coagulation management in trauma patients, introduces a selection of POC devices, and presents algorithms which allow a reduction in allogeneic blood product transfusion and an improvement of trauma patient outcome. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Impact of different storage times at room temperature of unspun citrated blood samples on routine coagulation tests results. Results of a bicenter study and review of the literature.

    PubMed

    Toulon, P; Metge, S; Hangard, M; Zwahlen, S; Piaulenne, S; Besson, V

    2017-10-01

    A maximum delay between blood collection and coagulation testing of 4 hours is recommended by most guidelines. As information on optimal storage times is limited, we investigated the potential effect of different storage times of unspun tubes, that is, ≤2, 4, 6, and 8 hours, on routine coagulation test results. Four evacuated polymer tubes containing 0.109 mol/L tri-Na citrate were drawn from 144 patients, including 39 patients on vitamin K-antagonists. Except for storage time, all tubes underwent the same preanalytical process. Prothrombin time (PT)/international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, factor V (FV), FVIII, and D-dimer were evaluated in two centers using the same technical conditions. Analytical comparison of aPTT, fibrinogen, FV, and FVIII results evaluated after prolonged storage times vs a <2-hours storage demonstrated significant difference, whereas PT/INR and D-dimer remained unchanged up to 8 hours. Mean bias between test results obtained after prolonged storage times remained below the desirable values for all studied parameters except for FVIII evaluated after 6- and 8-hours storages, but only in patients with FVIII above 100 IU/dL. Even though the corresponding bias of -5.2% and -8.5%, respectively, remained within the GEHT recommended limits of variation, its evaluation after an 8-hours storage could lead to significant underestimation of FVIII. These results suggest that, in the studied technical conditions, PT/INR, aPTT, fibrinogen, FV, and D-dimer can be reliably evaluated in tubes stored unspun at room temperature for up to 8 hours after blood collection. That optimal delay should be of 6 hours for FVIII. © 2017 The Authors. International Journal of Laboratory Hematology Published by John Wiley & Sons Ltd.

  2. Dysfibrinogenemia in childhood: two cases of congenital dysfibrinogens.

    PubMed

    Kotlín, Roman; Blažek, Bohumír; Suttnar, Jiří; Malý, Martin; Kvasnička, Jan; Dyr, Jan E

    2010-10-01

    A 2-year-old asymptomatic boy and his relatives were investigated for a suspected fibrinogen mutation after coagulation tests revealed a decreased functional fibrinogen level (family A). Eight-year-old and 1-year-old asymptomatic brothers were investigated for a suspected fibrinogen mutation after coagulation tests revealed a decreased functional fibrinogen level and prolonged thrombin time (family B). To identify whether genetic mutations were responsible for these dysfibrinogens, DNA extracted from the blood was analyzed. Fibrin polymerization and fibrinolysis were measured by a turbidimetric method at 450 nm. DNA analysis was performed by the Sanger method. Mass spectroscopy was performed on a Biflex IV mass spectrometer. DNA sequencing showed the heterozygous point mutation Aα Arg16His in the fibrinogen of family A and the heterozygous point mutation Aα Arg16Cys in the fibrinogen of family B. Kinetics of fibrinopeptide release, fibrinolysis, and fibrin polymerization were impaired in the carriers of the mutations in both families. Mass spectroscopy showed the presence of mutant fibrinogen chains in circulation. Scanning electron microscopy revealed thicker fibrin fibers, differing significantly from the normal control in both cases. Two cases of asymptomatic dysfibrinogenemias, found by routine coagulation testing, were genetically identified as new cases of fibrinogen variants Aα Arg16His and Aα Arg16Cys.

  3. Analysis of the characteristics and management of critical values in a newborn tertiary center in China.

    PubMed

    Wang, Zheng-Li; Du, Li-Zhong; Chen, Yi-Yu; Li, Lu-Quan; Lu, Qi; Liu, Ying; Cao, Lu-Ying; He, Yu; Yu, Jia-Lin

    2017-02-01

    Critical value reporting has been widely adopted by hospitals throughout the world, but there were few reports about neonatal critical values. This study aimed to analyze characteristics of the neonatal critical values considered at our center and to provide information on improving neonatal intensive care. A retrospective study of critical values at a newborn tertiary center in China was conducted to assess neonatal critical values according to test, distribution, reporting time, patient outcome and the impact to the therapy. In total, 926 critical values were recorded. Overall, 66.52% (616/926) of the items were reported within 24 hours of admission, 50.28% (465/926) during duty times and 54.75% (507/926) in the neonatal intensive care unit (NICU). The routine coagulation test was the most frequent source of critical values. Electrocardiography, blood gas analysis and therapeutic drug monitoring of drug levels were associated with the highest rates of treatment intervention (100%); routine coagulation tests were the lowest (23.14%). Sample quality was the main cause of false-positive critical values. The incidence of neonatal critical values peaked during the first 24 hours post-admission and during duty periods. Each newborn center needs to enact rapid treatment guidelines to address common critical values in order to facilitate clinical interventions. Periodically reviewing critical values could help to optimize clinical practices.

  4. A novel fibrinogen variant--Liberec: dysfibrinogenaemia associated with gamma Tyr262Cys substitution.

    PubMed

    Kotlín, Roman; Sobotková, Alzbeta; Suttnar, Jirí; Salaj, Peter; Walterová, Lenka; Riedel, Tomás; Reicheltová, Zuzana; Dyr, Jan Evangelista

    2008-08-01

    A 22-yr-old woman had abnormal preoperative coagulation test results and congenital dysfibrinogenaemia was suspected. The patient from Liberec (Czech Republic) had a low fibrinogen plasma level as determined by Clauss method, normal fibrinogen level as determined by immunoturbidimetrical method, and prolonged thrombin time. To identify the genetic mutation responsible for this dysfibrinogen, genomic DNA extracted from the blood was analysed. Fibrin polymerisation measurement, kinetics of fibrinopeptide release, fibrinogen clottability measurement and scanning electron microscopy were performed. DNA sequencing showed the heterozygous fibrinogen gamma Y262C mutation. Kinetics of fibrinopeptide release was normal, however fibrin polymerisation was impaired. Fibrinogen clottability measurement showed that only about 45% molecules of fibrinogen are involved in the clot formation. Scanning electron microscopy revealed thicker fibres, which were significantly different from the normal control. A case of dysfibrinogenaemia, found by routine coagulation testing, was genetically identified as a novel fibrinogen variant (gamma Y262C) that has been named Liberec.

  5. Validation of the minimal citrate tube fill volume for routine coagulation tests on ACL TOP 500 CTS®.

    PubMed

    Ver Elst, K; Vermeiren, S; Schouwers, S; Callebaut, V; Thomson, W; Weekx, S

    2013-12-01

    CLSI recommends a minimal citrate tube fill volume of 90%. A validation protocol with clinical and analytical components was set up to determine the tube fill threshold for international normalized ratio of prothrombin time (PT-INR), activated partial thromboplastin time (aPTT) and fibrinogen. Citrated coagulation samples from 16 healthy donors and eight patients receiving vitamin K antagonists (VKA) were evaluated. Eighty-nine tubes were filled to varying volumes of >50%. Coagulation tests were performed on ACL TOP 500 CTS(®) . Receiver Operating Characteristic (ROC) plot, with Total error (TE) and critical difference (CD) as possible acceptance criteria, was used to determine the fill threshold. Receiving Operating Characteristic was the most accurate with CD for PT-INR and TE for aPTT resulting in thresholds of 63% for PT and 80% for aPTT. By adapted ROC, based on threshold setting at a point of 100% sensitivity at a maximum specificity, CD was best for PT and TE for aPTT resulting in thresholds of 73% for PT and 90% for aPTT. For fibrinogen, the method was only valid with the TE criterion at a 63% fill volume. In our study, we validated the minimal citrate tube fill volumes of 73%, 90% and 63% for PT-INR, aPTT and fibrinogen, respectively. © 2013 John Wiley & Sons Ltd.

  6. Genetic parameters for milk coagulation properties in Estonian Holstein cows.

    PubMed

    Vallas, M; Bovenhuis, H; Kaart, T; Pärna, K; Kiiman, H; Pärna, E

    2010-08-01

    The objective of this study was to estimate heritabilities and repeatabilities for milk coagulation traits [milk coagulation time (RCT) and curd firmness (E(30))] and genetic and phenotypic correlations between milk yield and composition traits (milk fat percentage and protein percentage, urea, somatic cell count, pH) in first-lactation Estonian Holstein dairy cattle. A total of 17,577 test-day records from 4,191 Estonian Holstein cows in 73 herds across the country were collected during routine milk recordings. Measurements of RCT and E(30) determined with the Optigraph (Ysebaert, Frepillon, France) are based on an optical signal in the near-infrared region. The cows had at least 3 measurements taken during the period from April 2005 to January 2009. Data were analyzed using a repeatability animal model. There was substantial variation in milk coagulation traits with a coefficient of variation of 27% for E(30) and 9% for the log-transformed RCT. The percentage of variation explained by herd was 3% for E(30) and 4% for RCT, suggesting that milk coagulation traits are not strongly affected by herd conditions (e.g., feeding). Heritability was 0.28 for RCT and 0.41 for E(30), and repeatability estimates were 0.45 and 0.50, respectively. Genetic correlation between both milk coagulation traits was negligible, suggesting that RCT and E(30) have genetically different foundations. Milk coagulation time had a moderately high positive genetic (0.69) and phenotypic (0.61) correlation with milk pH indicating that a high pH is related to a less favorable RCT. Curd firmness had a moderate positive genetic (0.48) and phenotypic (0.45) correlation with the protein percentage. Therefore, a high protein percentage is associated with favorable curd firmness. All reported genetic parameters were statistically significantly different from zero. Additional univariate random regression analysis for milk coagulation traits yielded slightly higher average heritabilities of 0.38 and 0.47 for RCT and E(30) compared with the heritabilities of the repeatability model. Copyright (c) 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Real-time measurement of free thrombin: evaluation of the usability of a new thrombin assay for coagulation monitoring during extracorporeal circulation.

    PubMed

    Krajewski, Stefanie; Krauss, Sabrina; Kurz, Julia; Neumann, Bernd; Schlensak, Christian; Wendel, Hans P

    2014-03-01

    In patients undergoing cardiac surgery with heart-lung machine support, adequate anticoagulation to mitigate blood clotting caused by the artificial surfaces of the extracorporeal circulation (ECC) system is essential. These patients routinely receive heparin, whose effectiveness is monitored by measurements of the activated clotting time (ACT). However, ACT values only poorly correlate with the actual hemostatic status. The aim of our study was to evaluate the detection of free thrombin in heparinized human blood as a monitor of anticoagulation during ECC. Human whole blood was anticoagulated with different concentrations of heparin (0.75, 1, 2 or 3 IU/ml) and circulated in the Chandler-loop model for up to 240 min at 37 °C. Next to ACT, ECC-mediated changes in free active thrombin, prothrombin fragment 1+2 (F1+2) and thrombin-antithrombin-III (TAT) levels were measured before and during circulation. Platelet activation and cell count parameters were further investigated. Our study shows that detection of ECC-mediated changes in free thrombin is possible in blood anticoagulated with 0.75 or 1 IU/ml heparin, whereas no thrombin was detectable at higher heparin concentrations. Thrombin generation during 240 min of ECC is comparable to F 1+2 and TAT plasma levels during ECC. Thrombin is the key enzyme in the coagulation cascade and hence represents a promising marker for monitoring the coagulation status of patients. Although detection of free thrombin was not feasible at high heparin concentrations, the employed test represents an additional test to current laboratory methods investigating blood coagulation at low heparin concentrations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. A novel fibrinogen variant--Praha I: hypofibrinogenemia associated with gamma Gly351Ser substitution.

    PubMed

    Kotlín, Roman; Chytilová, Martina; Suttnar, Jirí; Salaj, Peter; Riedel, Tomás; Santrůcek, Jirí; Klener, Pavel; Dyr, Jan Evangelista

    2007-05-01

    A 25-yr-old man from Prague had abnormal bleeding after several surgical operations with low fibrinogen level and hypofibrinogenemia was suspected. The patient, 25 yr-old male had a low fibrinogen concentration as determined by the thrombin time and immunoturbidimetrical method. His 48-yr-old mother presented with normal coagulation tests, normal fibrinogen level and reported no history of bleeding. To identify the genetic mutation responsible for this hypofibrinogen, genomic DNA extracted from the blood was analyzed. Fibrin polymerization measurement, kinetics of fibrinopeptide release, fibrinogen clottability measurement, mass spectroscopy, and scanning electron microscopy were performed. DNA sequencing showed heterogeneous fibrinogen gammaG351S mutation in the propositus. The mutant chain was found not to be expressed to the circulation by matrix-assisted laser desorption/ionization time of flight mass spectrometry. Scanning electron micrographs of the patient's fibrin clot as well as kinetics of fibrinopeptide release and fibrin polymerization were found to be normal. A case of hypofibrinogenemia gammaG351S was found by routine coagulation testing and was genetically identified.

  9. Near-infrared fiber delivery systems for interstitial photothermal therapy

    NASA Astrophysics Data System (ADS)

    Slatkine, Michael; Mead, Douglass S.; Konwitz, Eli; Rosenberg, Zvi

    1995-05-01

    Interstitial photothermal coagulation has long been recognized as a potential important, minimally invasive modality for treating a variety of pathologic conditions. We present two different technologies for interstitial photothermal coagulation of tissue with infrared lasers: An optical fiber with a radially symmetric diffusing tip for deep coagulation, and a flat bare fiber for the coagulation of thin and long lesions by longitudinally moving the fiber while lasing in concert. Urology and Gynecology Fibers: The fibers are 600 microns diameter with 20 - 40 mm frosted distal tips protected by a smooth transparent cover. When used with a Neodymium:YAG (Nd:YAG) laser, the active fiber surface diffuses optical radiation in a radial pattern, delivering up to 40 W power, and thus providing consistent and uniform interstitial photothermal therapy. Coagulation depth ranges from 4 to 15 mm. Animal studies in the United States and clinical studies in Europe have demonstrated the feasibility of using these fibers to treat benign prostatic hyperplasia and endometrial coagulation. Rhinology Fiber: The fiber is an 800 micron diameter flat fiber operated at 8 W power level while being interstitially pushed and pulled along its axis. A long and thin coagulated zone is produced. The fiber is routinely used for the shrinking of hypertrophic turbinates without surrounding and bone mucusal damage in ambulatory environments.

  10. Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.

    PubMed

    Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan

    2017-05-15

    Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1μl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R 2 =0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. An Easy Method to Eliminate the Effect of Lupus Anticoagulants in the Coagulation Factor Assay.

    PubMed

    Tang, Ning; Yin, Shiyu

    2016-07-01

    To build and evaluate intrinsic coagulation factor assays which can eliminate the effect of lupus anticoagulants (LAC). Commercial silica clotting time confirmatory (SCT-C) reagent containing sufficient synthetic phospholipid and routine activated partial thromboplastin time (APTT) reagent were each used for one-stage detection of FVIII, FIX, and FXI activities, in samples with or without LAC, and the results were compared. For samples without LAC, consistent results of FVIII, FIX, and FXI using both SCT-C reagent and APTT reagent were obtained. For samples with LAC, the assays with SCT-C reagent not only could eliminate the effect of strong lupus anticoagulants but also needed fewer dilutions than that with routine APTT reagent. The intrinsic factor detections by SCT-C reagent are credible and convenient to be used for samples with LAC.

  12. Liquid Posterior Fossa Epidural Hematoma in Pediatric Trauma: A Single-Center Case Series.

    PubMed

    Han, Kun; Li, Zhaojian; Yin, Hongwei; Yao, Weicheng; Lan, Xiaolei; Bo, Yongli

    2018-06-14

     Liquid posterior fossa epidural hematoma (LPFEH) following head trauma is uncommon, and very few such cases have been described in the literature. Eight patients with this entity and their treatments are presented here.  We performed a single-institution retrospective analysis of all patients with diagnosed LPFEH over a 3-year period. Collected data included clinical history, laboratory results, treatment, and review of all imaging studies performed.  Eight pediatric cases were identified with imaging findings consistent with LPFEH; no adult case was identified. Enlargement of ventricles appeared on computed tomography (CT) in six cases, and secondary epilepsy onset occurred in three cases with severe dilated ventricles. Routine hematologic and coagulation tests failed to disclose anemia or abnormal coagulation in each case. Five patients underwent burr-hole drainage of the hematoma and recovered completely. Conservative therapy was adopted in three patients for small hematomas, and hematoma enlargement was not observed in the follow-up CT scans.  LPFEH is a rare subtype of traumatic epidural hematoma specifically recognized in the pediatric population. Minimally invasive burr-hole drainage is a feasible procedure for the patient with evident space-occupying effect. Coagulation dysfunction or low hemoglobin as a possible contributing factor and its role in formation of LPFEH was excluded. Georg Thieme Verlag KG Stuttgart · New York.

  13. Coagulation Factor Tests

    MedlinePlus

    ... your coagulation factors. Coagulation factors are known by Roman numerals (I, II VIII, etc.) or by name ( ... need this test if you have a family history of bleeding disorders. Most bleeding disorders are inherited . ...

  14. Preoperative Detailed Coagulation Tests Are Required in Patients With Noonan Syndrome.

    PubMed

    Morice, Anne; Harroche, Annie; Cairet, Pascale; Khonsari, Roman H

    2017-12-29

    Patients with Noonan syndrome often require surgery at young ages. They are at high risk of perioperative bleeding from coagulation defects that might not have been detected by routine screening. These risks are rarely described in the oral and maxillofacial surgery (OMS) literature. The aim of this study was to evaluate the perioperative bleeding risks associated with Noonan syndrome and to propose preoperative guidelines. This report describes a retrospective case series of patients with Noonan syndrome who underwent OMS procedures during a continuous observational period (2013 through 2016) in the authors' center. Clinical data, blood screening test results, and perioperative bleeding were analyzed. Five patients (age, 4 to 20 yr) with Noonan syndrome who underwent OMS procedures were included in this study. One patient presented a spontaneous bleeding tendency (epistaxis requiring cauterization). Blood screening showed clotting defects in 3 patients. One patient presented abnormal perioperative bleeding owing to a mild defect in factor XI. Patients with Noonan syndrome must be referred to a hematologist for specific preoperative investigations and for adapted perioperative management. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Changes in pre- and post-donation platelet function in plateletpheresis donors.

    PubMed

    Zhou, Q; Yu, X; Cai, Y; Liu, L

    2017-11-01

    This study aimed to investigate the changes of platelet (PLT) function and coagulation time before and after plateletpheresis donation. The healthy donors were divided into four groups according to the annual number of plateletpheresis donation: 20 times group, 15 times group, 10 times group and 5 times group. The healthy non-blood donors were selected as controls. The donation interval was 14 days. The blood samples were collected before plateletpheresis donation and after 30min, 7 d, and 14 d of donation for determination of coagulation time, PLT function, plasma protein, serum iron and blood routine change. After 30min of plateletpheresis donation, the PLT function decreased and the coagulation time was prolonged. However, PLT function recovered to the pre-collection after 7 d of plateletpheresis donation and coagulation time recovered to the pre-collection after 14 d of plateletpheresis donation. Additionally, there was no difference regarding blood coagulation time and PLT function among blood donors and controls. The plasma protein and serum iron levels in 20 times and 15 times groups were within the normal reference range. The frequency of plateletpheresis donation will not affect PLT function, coagulation time, plasma protein and serum iron in donors. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Effects of dairy factory, milk casein content and titratable acidity on coagulation properties in Trentingrana dairy industry.

    PubMed

    Penasa, Mauro; Toffanin, Valentina; Cologna, Nicola; Cassandro, Martino; De Marchi, Massimo

    2016-05-01

    The objective of the present study was to investigate the effect of environmental factors, milk casein content and titratable acidity on milk coagulation properties (MCP) of samples routinely collected in the Trento province (northeast Italy) under field conditions. Rennet coagulation time (RCT, min), curd-firming time (k20, min) and curd firmness (a30, mm) were determined by Formagraph on 14 971 samples from 635 herds associated to 17 dairy factories. Besides MCP, fat, protein, and casein percentages, titratable acidity (TA), and somatic cell and bacterial counts were available. A standardised index of milk aptitude to coagulate (IAC) was derived using information of RCT and a30. An analysis of variance was conducted on MCP and IAC using a fixed effects linear model. Approximately 3% of milk samples did not form a curd within the testing time (30 min) and k20 was missing for 26% of milks. The percentage of samples without information on k20 largely differed among dairy factories (1·7-20·9%). Significant differences were estimated between the best and the worst dairy factory for RCT (-2 min), k20 (-1·2 min), a30 (+3·4 mm) and IAC (+2·6 points). Milk casein content and TA were important factors in explaining the variation of MCP and IAC, supporting the central role of these two traits on technological properties. The Trento province is heterogeneous in terms of dairy systems and this could explain the differences among dairy factories.

  17. Optimum coagulant forecasting by modeling jar test experiments using ANNs

    NASA Astrophysics Data System (ADS)

    Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina

    2018-01-01

    Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests but also to predict a proper dosage for coagulant amounts and to project the quality of the output water under real conditions.

  18. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry.

    PubMed

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Lee, Seungmin; Murata, Aya; Omori, Shinji; Uchiyama, Hidetoshi; Inoue, Yoshinori; Kudo, Toshifumi; Toyofuku, Takahiro; Nagasawa, Masayuki; Uchimura, Isao; Nakamura, Tomomasa; Muneta, Takeshi

    2017-01-01

    In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability.

  19. Simultaneous assessment of blood coagulation and hematocrit levels in dielectric blood coagulometry

    PubMed Central

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Lee, Seungmin; Murata, Aya; Omori, Shinji; Uchiyama, Hidetoshi; Inoue, Yoshinori; Kudo, Toshifumi; Toyofuku, Takahiro; Nagasawa, Masayuki; Uchimura, Isao; Nakamura, Tomomasa; Muneta, Takeshi

    2017-01-01

    Background: In a whole blood coagulation test, the concentration of any in vitro diagnostic agent in plasma is dependent on the hematocrit level but its impact on the test result is unknown. Objective: The aim of this work was to clarify the effects of reagent concentration, particularly Ca2+, and to find a method for hematocrit estimation compatible with the coagulation test. Methods: Whole blood coagulation tests by dielectric blood coagulometry (DBCM) and rotational thromboelastometry were performed with various concentrations of Ca2+ or on samples with different hematocrit levels. DBCM data from a previous clinical study of patients who underwent total knee arthroplasty were re-analyzed. Results: Clear Ca2+ concentration and hematocrit level dependences of the characteristic times of blood coagulation were observed. Rouleau formation made hematocrit estimation difficult in DBCM, but use of permittivity at around 3 MHz made it possible. The re-analyzed clinical data showed a good correlation between permittivity at 3 MHz and hematocrit level (R2=0.83). Conclusions: Changes in the hematocrit level may affect whole blood coagulation tests. DBCM has the potential to overcome this effect with some automated correction using results from simultaneous evaluations of the hematocrit level and blood coagulability. PMID:28800301

  20. The Organophosphate Paraoxon and Its Antidote Obidoxime Inhibit Thrombin Activity and Affect Coagulation In Vitro

    PubMed Central

    Golderman, Valery; Shavit-Stein, Efrat; Tamarin, Ilia; Rosman, Yossi; Shrot, Shai; Rosenberg, Nurit

    2016-01-01

    Organophosphates (OPs) are potentially able to affect serine proteases by reacting with their active site. The potential effects of OPs on coagulation factors such as thrombin and on coagulation tests have been only partially characterized and potential interactions with OPs antidotes such as oximes and muscarinic blockers have not been addressed. In the current study, we investigated the in vitro interactions between coagulation, thrombin, the OP paraoxon, and its antidotes obidoxime and atropine. The effects of these substances on thrombin activity were measured in a fluorescent substrate and on coagulation by standard tests. Both paraoxon and obidoxime but not atropine significantly inhibited thrombin activity, and prolonged prothrombin time, thrombin time, and partial thromboplastin time. When paraoxon and obidoxime were combined, a significant synergistic effect was found on both thrombin activity and coagulation tests. In conclusion, paraoxon and obidoxime affect thrombin activity and consequently alter the function of the coagulation system. Similar interactions may be clinically relevant for coagulation pathways in the blood and possibly in the brain. PMID:27689805

  1. Electromagnetic induction sensor for dynamic testing of coagulation process.

    PubMed

    Wang, Zhe; Yu, Yuanhua; Yu, Zhanjiang; Chen, Qimeng

    2018-03-01

    With the increasing demand for coagulation POCT for patients in the surgery department or the ICU, rapid coagulation testing techniques and methods have drawn widespread attention from scholars and businessmen. This paper proposes the use of electromagnetic induction sensor probe for detection of dynamic process causing changes in the blood viscosity and density before and after coagulation based on the damped vibration principle, in order to evaluate the coagulation status. Utilizing the dynamic principle, the differential equation of vibration system comprising elastic support and electromagnetic induction device is established through sensor dynamic modeling. The structural parameters of elastic support are optimized, and the circular sheet spring is designed. Furthermore, harmonic response analysis and vibration fatigue coupling analysis are performed on the elastic support of the sensor by considering the natural frequency of the system, and the electromagnetic induction sensor testing device is set up. Using the device and coagulation reagent, the standard curve for coagulation POCT is plotted, and the blood sample application in clinical patients is established, which are methodologically compared with the imported POCT coagulation analyzer. The results show that the sensor designed in this paper has a first-order natural frequency of 11.368 Hz, which can withstand 5.295 × 10 2 million times of compressions and rebounds. Its correlation with the results of SONOCLOT analyzer reaches 0.996, and the reproducibility 0.002. The electromagnetic induction coagulation testing sensor designed has good elasticity and anti-fatigue, which can meet the accuracy requirement of clinical detection. This study provides the core technology for developing the electromagnetic induction POCT instrument for dynamic testing of coagulation process.

  2. Genotoxicity testing of cooked cured meat pigment (CCMP) and meat emulsion coagulates prepared with CCMP.

    PubMed

    Stevanović, M; Cadez, P; Zlender, B; Filipic, M

    2000-07-01

    The preformed cooked cured meat pigment (CCMP) synthesized directly from bovine red blood cells or through a hemin intermediate was found to be a viable colorant for application to comminuted pork as a nitrite substitute. However the genotoxicity of CCMP and meat emulsion coagulates prepared with CCMP has not been evaluated. Therefore the objectives of this work were to investigate genotoxicity of CCMP and the influence of CCMP addition on genotoxicity and the content of residual nitrite in model meat emulsion coagulates. Meat emulsions were prepared from white (musculus longissimus dorsi) and red (musculus quadriceps femoris) pork muscles with two different amounts of synthesized pigment CCMP. Comparatively, emulsions with fixed addition of nitrite salt and emulsions without any addition for color development were made. Genotoxicity of CCMP and meat emulsion coagulates was tested with the SOS/umu test and the Ames test. Neither CCMP nor meat emulsion coagulates prepared with CCMP or nitrite salt were genotoxic in the SOS/umu test. In the Ames test using Salmonella Typhimurium strains TA98 and TA100 samples of coagulates prepared with CCMP and with nitrite showed weak mutagenic activity in Salmonella Typhimurium strain TA100 but only in the absence of the metabolic activation, while CCMP was not mutagenic. Coagulates prepared with CCMP contained significantly less residual nitrite than coagulates prepared with nitrite salt. These results indicate that from the human health standpoint the substitution of nitrite salt with CCMP would be highly recommendable.

  3. New lab-made coagulant based on Schinopsis balansae tannin extract: synthesis optimization and preliminary tests on refractory water pollutants

    NASA Astrophysics Data System (ADS)

    Sánchez-Martín, J.; Beltrán-Heredia, J.; Coco-Rivero, B.

    2014-09-01

    Quebracho colorado tannin extract was used as a coagulant raw material for water and wastewater treatment. The chemical synthesis follows a Mannich reaction mechanism and provides a fully working coagulant that can remove several pollutants from water. This paper addresses the optimization of such synthesis and confirms the feasibility of the coagulant by testing it in a preliminary screening for the elimination of dyes and detergents. The optimum combination of reagents was 6.81 g of diethanolamine (DEA) and 2.78 g of formaldehyde (F) per g of tannin extract. So obtained coagulant was succesfully tested on the removal of 9 dyes and 8 detergents.

  4. Chemical coagulation of combined sewer overflow: heavy metal removal and treatment optimization.

    PubMed

    El Samrani, A G; Lartiges, B S; Villiéras, F

    2008-02-01

    The coagulation of combined sewer overflow (CSO) was investigated by jar-testing with two commercial coagulants, a ferric chloride solution (CLARFER) and a polyaluminium chloride (WAC HB). CSO samples were collected as a function of time during various wet-weather events from the inlet of Boudonville retention basin, Nancy, France. Jar-tests showed that an efficient turbidity removal can be achieved with both coagulants, though lower optimum dosages and higher re-stabilization concentrations were obtained with the aluminum-based coagulant. Optimum turbidity removal also yielded effective heavy metal elimination. However, the evolution with coagulant dosage of Cu, Zn, Pb, Cr, soluble and suspended solids contents followed various patterns. The removal behaviors can be explained by a selective aggregation of heavy metal carriers present in CSO and a specific interaction between hydrolyzed coagulant species and soluble metals. Stoichiometric relationships were established between optimal coagulant concentration, range of optimal dosing, and CSO conductivity, thus providing useful guidelines to adjust the coagulant demand during the course of CSO events.

  5. An updated concept of coagulation with clinical implications.

    PubMed

    Romney, Gregory; Glick, Michael

    2009-05-01

    Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.

  6. Short communication: Genetic correlation and heritability of milk coagulation traits within and across lactations in Holstein cows using multiple-lactation random regression animal models.

    PubMed

    Pretto, D; Vallas, M; Pärna, E; Tänavots, A; Kiiman, H; Kaart, T

    2014-12-01

    Genetic parameters of milk rennet coagulation time (RCT) and curd firmness (a30) among the first 3 lactations in Holstein cows were estimated. The data set included 39,960 test-day records from 5,216 Estonian Holstein cows (the progeny of 306 sires), which were recorded from April 2005 to May 2010 in 98 herds across the country. A multiple-lactation random regression animal model was used. Individual milk samples from each cow were collected during routine milk recording. These samples were analyzed for milk composition and coagulation traits with intervals of 2 to 3 mo in each lactation (7 to 305 DIM) and from first to third lactation. Mean heritabilities were 0.36, 0.32, and 0.28 for log-transformed RCT [ln(RCT)] and 0.47, 0.40, and 0.62 for a30 for parities 1, 2, and 3, respectively. Mean repeatabilities for ln(RCT) were 0.53, 0.55, and 0.56, but 0.59, 0.61, and 0.68 for a30 for parities 1, 2 and 3, respectively. Mean genetic correlations between ln(RCT) and a30 were -0.19, -0.14, and 0.02 for parities 1, 2, and 3, respectively. Mean genetic correlations were 0.91, 0.79, and 0.99 for ln(RCT), and 0.95, 0.94, and 0.94 for a30 between parities 1 and 2, 1 and 3, and 2 and 3, respectively. Due to these high genetic correlations, we concluded that for a proper genetic evaluation of milk coagulation properties it is sufficient to record RCT and a30 only in the first lactation. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  7. Applying the cell-based coagulation model in the management of critical bleeding.

    PubMed

    Ho, K M; Pavey, W

    2017-03-01

    The cell-based coagulation model was proposed 15 years ago, yet has not been applied commonly in the management of critical bleeding. Nevertheless, this alternative model may better explain the physiological basis of current coagulation management during critical bleeding. In this article we describe the limitations of the traditional coagulation protein cascade and standard coagulation tests, and explain the potential advantages of applying the cell-based model in current coagulation management strategies. The cell-based coagulation model builds on the traditional coagulation model and explains many recent clinical observations and research findings related to critical bleeding unexplained by the traditional model, including the encouraging results of using empirical 1:1:1 fresh frozen plasma:platelets:red blood cells transfusion strategy, and the use of viscoelastic and platelet function tests in patients with critical bleeding. From a practical perspective, applying the cell-based coagulation model also explains why new direct oral anticoagulants are effective systemic anticoagulants even without affecting activated partial thromboplastin time or the International Normalized Ratio in a dose-related fashion. The cell-based coagulation model represents the most cohesive scientific framework on which we can understand and manage coagulation during critical bleeding.

  8. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  9. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  10. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  11. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  12. 42 CFR 493.1269 - Standard: Hematology.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... materials must be tested in duplicate. (b) For all nonmanual coagulation test systems, the laboratory must...) For manual coagulation tests— (1) Each individual performing tests must test two levels of control...

  13. Does whole blood coagulation analysis reflect developmental haemostasis?

    PubMed

    Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette

    2017-04-01

    : Developmental haemostasis has been well documented over the last 3 decades and age-dependent reference ranges have been reported for a number of plasmatic coagulation parameters. With the increasing use of whole blood point-of-care tests like rotational thromboelastometry (ROTEM) and platelet function tests, an evaluation of age-dependent changes is warranted for these tests as well. We obtained blood samples from 149 children, aged 1 day to 5.9 years, and analysed conventional plasmatic coagulation tests, including activated partial prothrombin time, prothrombin time, and fibrinogen (functional). Whole blood samples were analysed using ROTEM to assess overall coagulation capacity and Multiplate analyzer to evaluate platelet aggregation. Age-dependent changes were analysed for all variables. We found age-dependent differences in all conventional coagulation tests (all P values < 0.05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P < 0.03). Despite marked differences in mean platelet aggregation between age groups, data did not reach statistical significance. Citrate-anticoagulated blood showed significantly reduced platelet aggregation compared with blood anticoagulated with heparin or hirudin (all P values < 0.003). We confirmed previous developmental changes in conventional plasmatic coagulation test. However, these age-dependent changes were not displayed in whole blood monitoring using ROTEM or Multiplate analyzer. Type of anticoagulant had a significant influence on platelet aggregation across all age groups.

  14. A novel suction/coagulation integrated probe for achieving better hemostasis: development and clinical use.

    PubMed

    Takahashi, Hidekazu; Haraguchi, Naotsugu; Nishimura, Junichi; Hata, Taishi; Matsuda, Chu; Yamamoto, Hirofumi; Mizushima, Tsunekazu; Mori, Masaki; Doki, Yuichiro; Nakajima, Kiyokazu

    2018-06-01

    Modern electrosurgical tools have a specific coagulation mode called "soft coagulation". However, soft coagulation has not been widely accepted for surgical operations. To optimize the soft coagulation environment, we developed a novel suction device integrated with an electrosurgical probe, called the "Suction ball coagulator" (SBC). In this study, we aimed to optimize the SBC design with a prototyping process involving a bench test and preclinical study; then, we aimed to demonstrate the feasibility, safety, and potential effectiveness of the SBC for laparoscopic surgery in clinical settings. SBC prototyping was performed with a bench test. Device optimization was performed in a preclinical study with a domestic swine bleeding model. Then, SBC was tested in a clinical setting during 17 clinical laparoscopic colorectal surgeries. In the bench tests, two tip hole sizes and patterns showed a good suction capacity. The preclinical study indicated the best tip shape for accuracy. In clinical use, no device-related adverse event was observed. Moreover, the SBC was feasible for prompt hemostasis and blunt dissections. In addition, SBC could evacuate vapors generated by tissue ablation using electroprobe during laparoscopic surgery. We successfully developed a novel, integrated suction/coagulation probe for hemostasis and commercialized it.

  15. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients

    PubMed Central

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-01-01

    Abstract Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests. Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed. The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values. Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients. PMID:27311005

  16. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients.

    PubMed

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-06-01

    Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests.Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed.The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values.Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients.

  17. Optical sensing of anticoagulation status: Towards point-of-care coagulation testing

    PubMed Central

    Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2017-01-01

    Anticoagulant overdose is associated with major bleeding complications. Rapid coagulation sensing may ensure safe and accurate anticoagulant dosing and reduce bleeding risk. Here, we report the novel use of Laser Speckle Rheology (LSR) for measuring anticoagulation and haemodilution status in whole blood. In the LSR approach, blood from 12 patients and 4 swine was placed in disposable cartridges and time-varying intensity fluctuations of laser speckle patterns were measured to quantify the viscoelastic modulus during clotting. Coagulation parameters, mainly clotting time, clot progression rate (α-angle) and maximum clot stiffness (MA) were derived from the clot viscoelasticity trace and compared with standard Thromboelastography (TEG). To demonstrate the capability for anticoagulation sensing in patients, blood samples from 12 patients treated with warfarin anticoagulant were analyzed. LSR clotting time correlated with prothrombin and activated partial thromboplastin time (r = 0.57–0.77, p<0.04) and all LSR parameters demonstrated good correlation with TEG (r = 0.61–0.87, p<0.04). To further evaluate the dose-dependent sensitivity of LSR parameters, swine blood was spiked with varying concentrations of heparin, argatroban and rivaroxaban or serially diluted with saline. We observed that anticoagulant treatments prolonged LSR clotting time in a dose-dependent manner that correlated closely with TEG (r = 0.99, p<0.01). LSR angle was unaltered by anticoagulation whereas TEG angle presented dose-dependent diminution likely linked to the mechanical manipulation of the clot. In both LSR and TEG, MA was largely unaffected by anticoagulation, and LSR presented a higher sensitivity to increased haemodilution in comparison to TEG (p<0.01). Our results establish that LSR rapidly and accurately measures the response of various anticoagulants, opening the opportunity for routine anticoagulation monitoring at the point-of-care or for patient self-testing. PMID:28771571

  18. Management of disseminated intravascular coagulation: a survey of the International Society on Thrombosis and Haemostasis.

    PubMed

    Di Nisio, Marcello; Thachil, Jecko; Squizzato, Alessandro

    2015-08-01

    It is not clear if and how international guidelines on the management of disseminated intravascular coagulation (DIC) are translated in routine clinical practice. A survey was conducted among different specialists who treat DIC. The survey examined six hypothetical case scenarios including the diagnosis of DIC, the treatment of non-overt and overt DIC with or without thrombosis, and the management of DIC patients at risk of bleeding or actively bleeding. There were 191 respondents and 73 returned complete questionnaires. Most of respondents were specialists in hematology (48%) or intensive care (30%). In suspected overt or non-overt DIC, only one third use formal diagnostic scores while two thirds rely on a broad panel of coagulation tests independently of any score. In non-overt DIC, 68% provide no treatment, but monitor laboratory tests. Monitoring was considered by 48% of respondents in overt DIC without thrombosis or bleeding. When a thrombotic or bleeding complication ensues, 29% consider intervening only if the event is major. In DIC patients judged at risk of bleeding, 67% use prophylactic transfusions, mostly fresh-frozen plasma (73%) and platelets (65%). Active bleeding is often managed with fresh-frozen plasma (83%) and platelet transfusions (68%) as first line and recombinant activated factor VII (31%) as second line treatment. This survey shows a largely heterogeneous approach of clinicians to the diagnosis and management of DIC. There is limited use of diagnostic scores despite guidelines' recommendations. The prevalent attitude seems monitoring DIC and limiting treatment to the underlying disease, unless thrombosis or bleeding develop, but modalities varied considerably. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Removal of total suspended solid by natural coagulant derived from cassava peel waste

    NASA Astrophysics Data System (ADS)

    Mohd-Asharuddin, S.; Othman, N.; Mohd-Zin, N. S.; Tajarudin, H. A.

    2018-04-01

    The present study was aimed to investigate the performance of starch derived from cassava peel waste as primary coagulant and coagulant aid. Comparable study was also conducted using commercially used aluminium sulfate (alum) as primary coagulant. A series of Jar tests were performed using raw water from Sembrong Barat water treatment plant. It was observed that coagulation test using cassava peel starch (CPS) alone had unappreciable removing ability. However, it was found that combination of alum-CPS successfully achieve up to 90.48% of total suspended solid (TSS) removal under optimized working conditions (pH 9, 7.5mg/L : 100 mg/L of alum : CPS dosage, rapid mixing of 200 rpm for 1 minute; 100 rpm for 2 minutes, slow mixing of 25 rpm for 30 minutes and 30 minutes settling time). This remarks the reduction in alum dosage up to 50% compared to coagulation test using alum alone. Therefore this finding suggesting that CPS can be considered as potential source of sustainable and effective coagulant aid for water treatment especially in developing countries.

  20. Enhanced coagulation for turbidity and Total Organic Carbon (TOC) removal from river Kansawati water.

    PubMed

    Narayan, Sumit; Goel, Sudha

    2011-01-01

    The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (< 2 mg/L)--high alkalinity water. Other water samples with higher TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.

  1. Implementation of a microcontroller-based semi-automatic coagulator.

    PubMed

    Chan, K; Kirumira, A; Elkateeb, A

    2001-01-01

    The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.

  2. Coagulation management in trauma-associated coagulopathy: allogenic blood products versus coagulation factor concentrates in trauma care.

    PubMed

    Klages, Matthias; Zacharowski, Kai; Weber, Christian Friedrich

    2016-04-01

    Coagulation management by transfusion of allogenic blood products and coagulation factors are competing concepts in current trauma care. Rapid and adequate therapy of trauma-associated coagulopathy is crucial to survival of severely injured patients. Standard coagulation tests such as prothrombin time and activated partial thromboplastin time are commonly used, but these tests are inappropriate for monitoring and guiding therapy in trauma patients. Coagulation factor-based treatment showed promising results, but randomized trials have not yet been performed. In addition, viscoelastic tests are needed to guide therapy, although there is in fact limited evidence for these in tests in trauma care. Regarding transfusion therapy with allogenic blood products, plasma transfusion has been associated with improved survival in trauma patients following massive transfusion. In contrast, patients not requiring massive transfusion seem to be at risk for suffering complications with increasing volumes of plasma transfused. The collective of trauma patients is heterogeneous. Despite the lack of evidence, there are strong arguments for individualized patient treatment with coagulation factors for some indications and to abstain from the use of fresh frozen plasma. In patients with severe trauma and major bleeding, plasma, platelets, and red blood cells should be considered to be administered at a ratio of 1 : 1 : 1.

  3. Biological and analytical variations of 16 parameters related to coagulation screening tests and the activity of coagulation factors.

    PubMed

    Chen, Qian; Shou, Weiling; Wu, Wei; Guo, Ye; Zhang, Yujuan; Huang, Chunmei; Cui, Wei

    2015-04-01

    To accurately estimate longitudinal changes in individuals, it is important to take into consideration the biological variability of the measurement. The few studies available on the biological variations of coagulation parameters are mostly outdated. We confirmed the published results using modern, fully automated methods. Furthermore, we added data for additional coagulation parameters. At 8:00 am, 12:00 pm, and 4:00 pm on days 1, 3, and 5, venous blood was collected from 31 healthy volunteers. A total of 16 parameters related to coagulation screening tests as well as the activity of coagulation factors were analyzed; these included prothrombin time, fibrinogen (Fbg), activated partial thromboplastin time, thrombin time, international normalized ratio, prothrombin time activity, activated partial thromboplastin time ratio, fibrin(-ogen) degradation products, as well as the activity of factor II, factor V, factor VII, factor VIII, factor IX, and factor X. All intraindividual coefficients of variation (CVI) values for the parameters of the screening tests (except Fbg) were less than 5%. Conversely, the CVI values for the activity of coagulation factors were all greater than 5%. In addition, we calculated the reference change value to determine whether a significant difference exists between two test results from the same individual. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Development and Implementation of a Coagulation Factor Testing Method Utilizing Autoverification in a High-volume Clinical Reference Laboratory Environment

    PubMed Central

    Riley, Paul W.; Gallea, Benoit; Valcour, Andre

    2017-01-01

    Background: Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. Methods: The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Results: Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. Conclusions: To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process. PMID:28706751

  5. Development and Implementation of a Coagulation Factor Testing Method Utilizing Autoverification in a High-volume Clinical Reference Laboratory Environment.

    PubMed

    Riley, Paul W; Gallea, Benoit; Valcour, Andre

    2017-01-01

    Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process.

  6. Adherence and Coagulation Assays in Dabigatran-treated Patients With Atrial Fibrillation

    ClinicalTrials.gov

    2017-09-12

    Atrial Fibrillation; Medication Adherence; Blood Coagulation Tests; Anticoagulants; Circulating, Hemorrhagic Disorder; Drug Effect; Drug Use; Drug Toxicity; Drug Intolerance; Blood Clot; Blood Coagulation Disorder; Laboratory Problem; Bleeding; Thrombosis

  7. Improvement of the coagulation/flocculation process using a combination of Moringa oleifera lam with anionic polymer in water treatment.

    PubMed

    Bongiovani, Milene Carvalho; Camacho, Franciele Pereira; Nishi, Letícia; Coldebella, Priscila Ferri; Valverde, Karina Cardoso; Vieira, Angélica Marquetotti Salcedo; Bergamasco, Rosângela

    2014-01-01

    The objective of this study is to investigate the impacts of anionic polymer as a flocculant aid on the coagulation/flocculation performance with a saline solution of Moringa oleifera as a coagulant to provide larger flocs and decrease the time sedimentation. For the tests, raw water was used from Pirapó River Basin (Maringá, Paraná, Brazil). Optimization of coagulation/flocculation tests was initially performed in a jar-test with a dosage of M. oleifera Lam (crude extract--MO, oil-extracted with ethanol--MO (et) and hexane--MO (hex) 1% m/v) as the coagulant that ranged from 10 to 60 mg L(-1) and of the anionic polymer 0.1% as a flocculant aid with a dosage that ranged from 0 to 0.4 mg L(-1). The parameters analysed were colour, turbidity and compounds with absorption in UV254nm. In view of the statistical analysis results, MO (hex) with a dosage of 30 mg L(-1) was chosen as a coagulant for the next tests of coagulation/flocculation. When anionic polymer was used alone (0.0 mg L(-1) of MO (hex)), parameters were not removed and there was no generation of heavy flocs as compared with the combination of MO (hex) with the anionic polymer. Statistical analysis showed that MO (hex) obtained the highest removals of the parameters analysed in lower dosages and no significant increase in parameters removal was observed when the polymer dosage was increased. The efficacy of the coagulant +/- anionic polymer was optimal when 30mg L(-1) of MO (hex) was used as a coagulant and 0.1 mg L(-1) of the anionic polymer was used as a flocculant aid, decreasing the time sedimentation from 1 h to 15 min.

  8. Coagulation tests show significant differences in patients with breast cancer.

    PubMed

    Tas, Faruk; Kilic, Leyla; Duranyildiz, Derya

    2014-06-01

    Activated coagulation and fibrinolytic system in cancer patients is associated with tumor stroma formation and metastasis in different cancer types. The aim of this study is to explore the correlation of blood coagulation assays for various clinicopathologic factors in breast cancer patients. A total of 123 female breast cancer patients were enrolled into the study. All the patients were treatment naïve. Pretreatment blood coagulation tests including PT, APTT, PTA, INR, D-dimer, fibrinogen levels, and platelet counts were evaluated. Median age of diagnosis was 51 years old (range 26-82). Twenty-two percent of the group consisted of metastatic breast cancer patients. The plasma level of all coagulation tests revealed statistically significant difference between patient and control group except for PT (p<0.001 for all variables except for PT; p=0.08). Elderly age (>50 years) was associated with higher D-dimer levels (p=0.003). Metastatic patients exhibited significantly higher D-dimer values when compared with early breast cancer patients (p=0.049). Advanced tumor stage (T3 and T4) was associated with higher INR (p=0.05) and lower PTA (p=0.025). In conclusion, coagulation tests show significant differences in patients with breast cancer.

  9. Establishment of reference values for various coagulation tests in healthy Florida manatees (Trichechus manatus latirostris) and evaluation of coagulation in debilitated manatees during rehabilitation.

    PubMed

    Gerlach, Trevor J; Bandt, Carsten; Conner, Bobbi; Ball, Ray L

    2015-11-01

    To establish reference ranges for coagulation parameters in healthy Florida manatees (Trichechus manatus latirostris) and compare results with those for debilitated manatees undergoing treatment at a rehabilitation facility. Prospective study. 29 healthy manatees and 45 debilitated manatees with various diseases. Manatees considered healthy on the basis of results of physical examination, CBC, and serum biochemical analysis underwent coagulation testing including measurement of prothrombin time, partial thromboplastin time, D-dimer concentration, platelet count, and fibrinogen concentration to establish reference ranges. For comparison, a group of manatees undergoing rehabilitation was also tested, and the results were compared. Thromboelastography was also performed on some animals. Values for D-dimer concentration were significantly higher in debilitated versus healthy animals. There was no significant difference for prothrombin time, partial thromboplastin time, platelet count, or fibrinogen concentration between groups. Thromboelastography was performed on 8 healthy animals. Reference ranges were established for various tests of coagulation that may assist clinicians during the initial evaluation and rehabilitation of Florida manatees. Future research to evaluate the effect of specific disease processes on the coagulation cascade is recommended.

  10. Viscoelastic blood coagulation measurement with Sonoclot predicts postoperative bleeding in cardiac surgery after heparin reversal.

    PubMed

    Bischof, Dominique B; Ganter, Michael T; Shore-Lesserson, Linda; Hartnack, Sonja; Klaghofer, Richard; Graves, Kirk; Genoni, Michele; Hofer, Christoph K

    2015-01-01

    The aim of the study was to determine if Sonoclot with its sensitive glass bead-activated, viscoelastic test can predict postoperative bleeding in patients undergoing cardiac surgery at predefined time points. A prospective, observational clinical study. A teaching hospital, single center. Consecutive patients undergoing cardiac surgery (N = 300). Besides routine laboratory coagulation studies and heparin management with standard (kaolin) activated clotting time, additional native blood samples were analyzed on a Sonoclot using glass bead-activated tests. Glass bead-activated clotting time, clot rate, and platelet function were recorded immediately before anesthesia induction and at the end of surgery after heparin reversal but before chest closure. Primary outcome was postoperative blood loss (chest tube drainage at 4, 8, and 12 hours postoperatively). Secondary outcome parameters were transfusion requirements, need for surgical re-exploration, time of mechanical ventilation, length of intensive care unit and hospital stay, and hospital morbidity and mortality. Patients were categorized into "bleeders" and "nonbleeders." Patient characteristics, operations, preoperative standard laboratory parameters, and procedural times were comparable between bleeders and nonbleeders except for sex and age. Bleeders had higher rates of transfusions, surgical re-explorations, and complications. Only glass bead measurements by Sonoclot after heparin reversal before chest closure but not preoperatively were predictive for increased postoperative bleeding. Sonoclot with its glass bead-activated tests may predict the risk for postoperative bleeding in patients undergoing cardiac surgery at the end of surgery after heparin reversal but before chest closure. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Biological evaluation of the effect of sugammadex on hemostasis and bleeding

    PubMed Central

    Guerci, Philippe; Harter, Valentin; Fuchs-Buder, Thomas; Meistelman, Claude

    2015-01-01

    Background Notification of sugammadex has been supplemented with a section on hemostasis, including a longer clotting time in the first minutes following injection, without any documented clinical consequences. The objective of this observational study was to analyze the effects of sugammadex administration on routine coagulation tests and bleeding in the clinical setting. Methods After Institutional Review Board approval, a prospective observational study was conducted between January and December 2011. Adult patients scheduled for laparotomies were analyzed in groups according to the type of reversal (without sugammadex versus 2 or 4 mg/kg sugammadex). There were no changes in our current clinical practice. Blood samples drawn from these patients were standardized at the same time and tested using the same daily calibrated machine. The endpoint was a comparison of the activated partial thromboplastin time (aPTT), prothrombin time (PT), hemoglobin (Hb) level and hematocrit (Ht), immediately before sugammadex administration (H0) and 1 h after neuromuscular block reversal (H1). Results One hundred and forty-two patients in three groups were included as follows: 11 in the "without sugammadex" group, 64 in the "2 mg/kg sugammadex" group and 67 in the "4 mg/kg sugammadex" group. Results did not differ significantly among the groups. Conclusions In this prospective observational study, the use of 2 and 4 mg/kg sugammadex was not associated with a longer clotting time or decreased hemoglobin concentrations. Future prospective investigations should study patients receiving 16 mg/kg sugammadex and/or with abnormal coagulation tests. PMID:25664150

  12. Effect of adsorbent addition on floc formation and clarification.

    PubMed

    Younker, Jessica M; Walsh, Margaret E

    2016-07-01

    Adding adsorbent into the coagulation process is an emerging treatment solution for targeting hard-to-remove dissolved organic compounds from both drinking water and industrial wastewater. The impact of adding powdered activated carbon (PAC) or organoclay (OC) adsorbents with ferric chloride (FeCl3) coagulant was investigated in terms of potential changes to the coagulated flocs formed with respect to size, structure, and breakage and regrowth properties. The ability of dissolved air flotation (DAF) and sedimentation (SED) clarification processes to remove hybrid adsorbent-coagulant flocs was also evaluated through clarified water quality analysis of samples collected in bench-scale jar test experiments. The jar tests were conducted using both a synthetic fresh water and oily wastewater test water spiked with dissolved aromatic compounds phenol and naphthalene. Results of the study demonstrated that addition of adsorbent reduced the median coagulated floc size by up to 50% but did not affect floc strength or regrowth potential after application of high shear. Experimental results in fresh water demonstrated that sedimentation was more effective than DAF for clarification of both FeCl3-PAC and FeCl3-OC floc aggregates. However, experimental tests performed on the synthetic oily wastewater showed that coagulant-adsorbent floc aggregates were effectively removed with both DAF and sedimentation treatment, with lower residual turbidity achieved in clarified water samples than with coagulation treatment alone. Addition of OC or PAC into the coagulation process resulted in removals of over half, or nearly all of the dissolved aromatics, respectively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Could light meal jeopardize laboratory coagulation tests?

    PubMed

    Lima-Oliveira, Gabriel; Salvagno, Gian Luca; Lippi, Giuseppe; Danese, Elisa; Gelati, Matteo; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2014-01-01

    Presently the necessity of fasting time for coagulation tests is not standardized. Our hypothesis is that this can harm patient safety. This study is aimed at evaluating whether a light meal (i.e. breakfast) can jeopardize laboratory coagulation tests. A blood sample was firstly collected from 17 fasting volunteers (12 h). Immediately after blood collection, the volunteers consumed a light meal. Then samples were collected at 1, 2 and 4 h after the meal. Coagulation tests included: activated partial thromboplastin time (APTT), prothrombin time (PT), fibrinogen (Fbg), antithrombin III (AT), protein C (PC) and protein S (PS). Differences between samples were assessed by Wilcoxon ranked-pairs test. The level of statistical significance was set at P < 0.05. Mean % differences were determined and differences between and baseline and 1, 2 and 4h samples were compared with reference change value (RCV). A significantly higher % activity of AT was observed at 1 h and 4 h after meal vs. baseline specimen [113 (104-117) and 111 (107-120) vs. 109 (102-118), respectively; P = 0.029 and P = 0.016]. APTT at 2 h was found significantly lower than baseline samples [32.0 (29.9-34.8) vs. 34.1 (32.2-35.2), respectively; P = 0.041]. The results of both Fbg and PS tests were not influenced by a light meal. Furthermore, no coagulation tests had significant variation after comparison with RCV. A light meal does not influence the laboratory coagulation tests we assessed, but we suggest that the laboratory quality managers standardize the fasting time for all blood tests at 12 hours, to completely metabolize the lipids intake.

  14. Effective estimation of correct platelet counts in pseudothrombocytopenia using an alternative anticoagulant based on magnesium salt

    PubMed Central

    Schuff-Werner, Peter; Steiner, Michael; Fenger, Sebastian; Gross, Hans-Jürgen; Bierlich, Alexa; Dreissiger, Katrin; Mannuß, Steffen; Siegert, Gabriele; Bachem, Maximilian; Kohlschein, Peter

    2013-01-01

    Pseudothrombocytopenia remains a challenge in the haematological laboratory. The pre-analytical problem that platelets tend to easily aggregate in vitro, giving rise to lower platelet counts, has been known since ethylenediamine-tetra acetic acid EDTA and automated platelet counting procedures were introduced in the haematological laboratory. Different approaches to avoid the time and temperature dependent in vitro aggregation of platelets in the presence of EDTA were tested, but none of them proved optimal for routine purposes. Patients with unexpectedly low platelet counts or flagged for suspected aggregates, were selected and smears were examined for platelet aggregates. In these cases patients were asked to consent to the drawing of an additional sample of blood anti-coagulated with a magnesium additive. Magnesium was used in the beginning of the last century as anticoagulant for microscopic platelet counts. Using this approach, we documented 44 patients with pseudothrombocytopenia. In all cases, platelet counts were markedly higher in samples anti-coagulated with the magnesium containing anticoagulant when compared to EDTA-anticoagulated blood samples. We conclude that in patients with known or suspected pseudothrombocytopenia the magnesium-anticoagulant blood samples may be recommended for platelet counting. PMID:23808903

  15. Neutralization of crotaline snake venoms from Central and South America by antivenoms produced in Brazil and Costa Rica.

    PubMed

    Bogarín, G; Morais, J F; Yamaguchi, I K; Stephano, M A; Marcelino, J R; Nishikawa, A K; Guidolin, R; Rojas, G; Higashi, H G; Gutiérrez, J M

    2000-10-01

    A study was performed on the ability of antivenoms, produced in Brazil and Costa Rica, to neutralize lethal, hemorrhagic and coagulant activities of the venoms of 16 species of Central and South American snakes of the subfamily Crotalinae. Neutralization of lethality was studied by two different methods routinely used in the quality control of antivenoms at Instituto Butantan (IB) and Instituto Clodomiro Picado (ICP). Both antivenoms neutralized the majority of the venoms studied, but the values of effective doses 50% (ED(50)) differed markedly depending on the method used. In general, higher potencies were obtained with the method of ICP, where a challenge dose corresponding to 4 LD(50)s is used, than with the method of IB, where a challenge dose of 5 LD(50)s is employed. All venoms induced hemorrhagic activity in the mouse skin test, which was effectively neutralized by the two antivenoms. All venoms, except those of Porthidium nasutum and Bothriechis lateralis, induced coagulation of human plasma in vitro and both antivenoms were effective in the neutralization of this activity. In conclusion, our results provide evidence of an extensive cross reactivity between these antivenoms and Central and South American crotaline snake venoms.

  16. To mix or not to mix venous blood samples collected in vacuum tubes?

    PubMed

    Parenmark, Anna; Landberg, Eva

    2011-09-08

    There are recommendations to mix venous blood samples by inverting the tubes immediately after venipuncture. Though mixing allows efficient anticoagulation in plasma tubes and fast initiation of coagulation in serum tubes, the effect on laboratory analyses and risk of haemolysis has not been thoroughly evaluated. Venous blood samples were collected by venipuncture in vacuum tubes from 50 patients (10 or 20 patients in each group). Four types of tubes and 18 parameters used in routine clinical chemistry were evaluated. For each patient and tube, three types of mixing strategies were used: instant mixing, no mixing and 5 min of rest followed by mixing. Most analyses did not differ significantly in samples admitted to different mixing strategies. Plasma lactate dehydrogenase and haemolysis index showed a small but significant increase in samples omitted to instant mixing compared to samples without mixing. However, in one out of twenty non-mixed samples, activated partial thromboplastin time was seriously affected. These results indicate that mixing blood samples after venipuncture is not mandatory for all types of tubes. Instant mixing may introduce interference for those analyses susceptible to haemolysis. However, tubes with liquid-based citrate buffer for coagulation testing should be mixed to avoid clotting.

  17. In Vitro Assessment of Nanoparticle Effects on Blood Coagulation.

    PubMed

    Potter, Timothy M; Rodriguez, Jamie C; Neun, Barry W; Ilinskaya, Anna N; Cedrone, Edward; Dobrovolskaia, Marina A

    2018-01-01

    Blood clotting is a complex process which involves both cellular and biochemical components. The key cellular players in the blood clotting process are thrombocytes or platelets. Other cells, including leukocytes and endothelial cells, contribute to clotting by expressing the so-called pro-coagulant activity (PCA) complex on their surface. The biochemical component of blood clotting is represented by the plasma coagulation cascade, which includes plasma proteins also known as coagulation factors. The coordinated interaction between platelets, leukocytes, endothelial cells, and plasma coagulation factors is necessary for maintaining hemostasis and for preventing excessive bleeding. Undesirable activation of all or some of these components may lead to pathological blood coagulation and life-threatening conditions such as consumptive coagulopathy or disseminated intravascular coagulation (DIC). In contrast, unintended inhibition of the coagulation pathways may lead to hemorrhage. Thrombogenicity is the property of a test material to induce blood coagulation by affecting one or more elements of the clotting process. Anticoagulant activity refers to the property of a test material to inhibit coagulation. The tendency to cause platelet aggregation, perturb plasma coagulation, and induce leukocyte PCA can serve as an in vitro measure of a nanomaterial's likelihood to be pro- or anticoagulant in vivo. This chapter describes three procedures for in vitro analyses of platelet aggregation, plasma coagulation time, and activation of leukocyte PCA. Platelet aggregation and plasma coagulation procedures have been described earlier. The revision here includes updated details about nanoparticle sample preparation, selection of nanoparticle concentration for the in vitro study, and updated details about assay controls. The chapter is expanded to describe a method for the leukocyte PCA analysis and case studies demonstrating the performance of these in vitro assays.

  18. Use of viscoelastic haemostatic assay in emergency and elective surgery.

    PubMed

    Yeung, Maximus C F; Tong, Steven Y T; Tong, Paul Y W; Cheung, Billy H H; Ng, Joanne Y W; Leung, Gilberto K K

    2015-02-01

    To review the current evidence for the use of viscoelastic haemostatic assays in different surgical settings including trauma, cardiac surgery, liver transplantation, as well as the monitoring of antiplatelet agents and anticoagulants prior to surgery. PubMed database. Key words for the literature search were "thromboelastography" or "ROTEM" in combination with "trauma", "antiplatelet", "cardiac surgery", "liver transplantation" or "anticoagulants". Original and major review articles related to the use of viscoelastic haemostatic assays. Haemostatic function is a critical factor determining patient outcomes in emergency or elective surgery. The increasing use of antiplatelet agents and anticoagulants has potentially increased the risks of haemorrhages and the need for transfusion. Conventional coagulation tests have limitations in detecting haemostatic dysfunctions in subgroups of patients and are largely ineffective in diagnosing hyperfibrinolysis. The viscoelastic haemostatic assays are potentially useful point-of-care tools that provide information on clot formation, clot strength, and fibrinolysis, as well as to guide goal-directed transfusion and antifibrinolytic therapy. They may also be used to monitor antiplatelet and anticoagulant therapy. However, standardisation of techniques and reference ranges is required before these tests can be widely used in different clinical settings. Viscoelastic haemostatic assays, as compared with conventional coagulation tests, are better for detecting coagulopathy and are the only tests that can provide rapid diagnosis of hyperfibrinolysis. Goal-directed administration of blood products based on the results of viscoelastic haemostatic assays was associated with reduction in allogeneic blood product transfusions in trauma, cardiac surgery, and liver transplantation cases. However, there is currently no evidence to support the routine use of viscoelastic haemostatic assays for monitoring platelet function prior to surgery.

  19. Microalgae removal with Moringa oleifera.

    PubMed

    Barrado-Moreno, M M; Beltran-Heredia, J; Martín-Gallardo, J

    2016-02-01

    Moringa oleifera seed extract was tested for algae (Chlorella, Microcystis, Oocystis and Scenedesmus) removal by Jar-test technique. This coagulant can be used in drinking water treatment. Jar-test has been carried out in order to evaluate the efficiency of this natural coagulant agent inside real surface water matrix. The influence of variables has been studied in this process, including operating parameters such as coagulant dosage, initial algae concentration, pH, agitation time and water matrix. Removal capacity is verified for water with high contamination of algae while the process is not affected by the pH and water matrix. Coagulation process may be modelling through Langmuir and Freundlich adsorption hypothesis, so acceptable r2 coefficients are obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Colloids removal from water resources using natural coagulant: Acacia auriculiformis

    NASA Astrophysics Data System (ADS)

    Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.

    2017-09-01

    All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.

  1. Methodical aspects of blood coagulation measurements in birds applying commercial reagents--a pilot study.

    PubMed

    Guddorf, Vanessa; Kummerfeld, Norbert; Mischke, Reinhard

    2014-01-01

    The aim of this study was to examine the suitability of commercially available reagents for measurements of coagulation parameters in citrated plasma from birds. Therefore, plasma samples of 17 healthy donor birds of different species were used to determine prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT) applying various commercial reagents which are routinely used in coagulation diagnostics in humans and mammals. A PT reagent based on human placental thromboplastin yielded not only shorter clotting times than a reagent containing recombinant human tissue factor (median 49 vs. 84 s), but also showed a minor range of distribution of values (43-55 s vs. 30-147 s, minimum-maximum, n = 5 turkeys). An aPTT reagent containing kaolin and phospholipids of animal origin delivered the shortest clotting times and the lowest range of variation in comparison to three other reagents of different composition. However, even when this reagent was used, aPTTs were partially extremely long (> 200 s). Thrombin time was 38 s (28-57 s, n = 5 chicken) when measured with bovine thrombin at a final concentration of 2 IU thrombin/ ml. Coefficients of variation for within-run precision analysis (20 repetitions) of PT was 8.0% and 4.7% for aPTT measurements using selected reagents of mammalian origin. In conclusion, of the commercially available reagents tested, a PT reagent based on human placental thromboplastin and an aPTT reagent including rabbit brain phospholipid and kaolin, show some promise for potential use in birds.

  2. A comparative study of tissue factor and kaolin on blood coagulation assays using rotational thromboelastometry and thromboelastography.

    PubMed

    Peng, Henry T; Grodecki, Richard; Rizoli, Sandro; Shek, Pang N

    2016-01-01

    Rotational thromboelastometry (ROTEM) and thromboelastography (TEG) have been increasingly used to diagnose acute coagulopathy and guide blood transfusion. The tests are routinely performed using different triggering activators such as tissue factor and kaolin, which activate different pathways yielding different results. To optimize the global blood coagulation assays using ROTEM and TEG, we conducted a comparative study on the activation methods employing tissue factor and kaolin at different concentrations as well as standard reagents as recommended by the manufacturer of each device. Key parameter values were obtained at various assay conditions to evaluate and compare coagulation and fibrinolysis profiles of citrated whole blood collected from healthy volunteers. It was found that tissue factor reduced ROTEM clotting time and TEG R, and increased ROTEM clot formation time and TEG K in a concentration-dependent manner. In addition, tissue factor affected ROTEM alpha angle, and maximum clot firmness, especially in the absence of kaolin activation, whereas both ROTEM and TEG clot lysis (LI30, CL30, and LY30) remained unaffected. Moreover, kaolin reduced ROTEM clotting time and TEG R and K, but to a lesser extent than tissue factor, in-tem and ex-tem. Correlations in all corresponding parameters between ROTEM and TEG were observed, when the same activators were used in the assays compared with lesser correlations between standard kaolin TEG and ROTEM (INTEM/EXTEM). The two types of viscoelastic point-of-care devices provide different results, depending on the triggering reagent used to perform the assay. Optimal assay condition was obtained to reduce assay time and improve assay accuracy.

  3. The incidence of un-indicated preoperative testing in a tertiary academic ambulatory center: a retrospective cohort study.

    PubMed

    Onuoha, Onyi C; Hatch, Michael B; Miano, Todd A; Fleisher, Lee A

    2015-01-01

    Despite existing evidence and guidelines advocating for appropriate risk stratification, ambulatory surgery in low-risk patients continues to be accompanied by a battery of routine tests prior to surgery. Using a single-center retrospective cohort study, we aimed to quantify the incidence of un-indicated preoperative testing in an academic ambulatory center by utilizing recommendations by the recently developed American Society of Anesthesiology (ASA) "Choosing Wisely" Top-5 list. We utilized data from the EPIC medical records of 3111 patients who had ambulatory surgery at the Hospital of the University of Pennsylvania during a 6-month period. Data were abstracted from laboratory studies- complete blood count, electrolyte panel, coagulation studies, and cardiac studies-stress test, and echocardiogram obtained within 30 days prior to surgery. Preoperative tests obtained from each patient were categorized into "indicated" (ASA ≥ 3) and "un-indicated" (ASA 1 and 2) tests, and percentages were reported. During the study period, 52.9 % (95 % confidence interval (CI) 37.6-66.4) of all patients had at least one un-indicated laboratory test performed preoperatively. Further analysis revealed variation in the incidence of preoperative ordering between tests; 73 % of all complete blood counts (CBCs), 70 % of all metabolic panels, and 49 % of all coagulation studies were considered un-indicated by "Top-5 List" criteria. Stated differently, of the patients included in the sample, 51 % of patients received an un-indicated CBC, 41 % an un-indicated metabolic panel, and 16 % un-indicated coagulation studies. Twelve percent of "any un-indicated preoperative test" were obtained from ASA 1 healthy patients. Of the 587 patients less than 36 years old, 331 (56 %) had at least one test that was deemed un-indicated. Forty-one patients had either an echocardiogram or stress test ordered and performed within 30 days of surgery. Of these, eight (19.5 %) studies were un-indicated as determined by chart review. The incidence of ordering "at least one un-indicated preoperative test" in low-risk patients undergoing low-risk surgery remains high even in academic tertiary institutions. In the emerging era of optimizing patient safety and financial accountability, further studies are needed to better understand the problem of overuse while identifying modifiable attitudes and institutional influences on perioperative practices among all stakeholders involved. Such information would drive the development of feasible interventions.

  4. A new approach using coagulation rate constant for evaluation of turbidity removal

    NASA Astrophysics Data System (ADS)

    Al-Sameraiy, Mukheled

    2017-06-01

    Coagulation-flocculation-sedimentation processes for treating three levels of bentonite synthetic turbid water using date seeds (DS) and alum (A) coagulants were investigated in the previous research work. In the current research, the same experimental results were used to adopt a new approach on a basis of using coagulation rate constant as an investigating parameter to identify optimum doses of these coagulants. Moreover, the performance of these coagulants to meet (WHO) turbidity standard was assessed by introducing a new evaluating criterion in terms of critical coagulation rate constant (kc). Coagulation rate constants (k2) were mathematically calculated in second order form of coagulation process for each coagulant. The maximum (k2) values corresponded to doses, which were obviously to be considered as optimum doses. The proposed criterion to assess the performance of coagulation process of these coagulants was based on the mathematical representation of (WHO) turbidity guidelines in second order form of coagulation process stated that (k2) for each coagulant should be ≥ (kc) for each level of synthetic turbid water. For all tested turbid water, DS coagulant could not satisfy it. While, A coagulant could satisfy it. The results obtained in the present research are exactly in agreement with the previous published results in terms of finding optimum doses for each coagulant and assessing their performances. On the whole, it is recommended considering coagulation rate constant to be a new approach as an indicator for investigating optimum doses and critical coagulation rate constant to be a new evaluating criterion to assess coagulants' performance.

  5. The effects of chemical coagulants on the decolorization of dyes by electrocoagulation using response surface methodology (RSM)

    NASA Astrophysics Data System (ADS)

    Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver

    2017-09-01

    This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.

  6. Metals in airpollution particles decrease whole blood coagulation time

    EPA Science Inventory

    The mechanism underlying the pro-coagulative effect of air pollution particle exposure is not known. We tested the postulate that 1) the soluble fraction ofan air pollution particle can affect whole blood coagulation time and 2) metals included in the soluble fraction are respons...

  7. Critical assessment of chitosan as coagulant to remove cyanobacteria.

    PubMed

    Lürling, Miquel; Noyma, Natalia Pessoa; de Magalhães, Leonardo; Miranda, Marcela; Mucci, Maíra; van Oosterhout, Frank; Huszar, Vera L M; Marinho, Marcelo Manzi

    2017-06-01

    Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial blooms, as well as high alkalinity may hamper the coagulation of chitosan and thus impair its ability to effectively remove positively buoyant cyanobacteria from the water column. The underlying mechanism is likely a shielding of the protonated groups by anions. Inasmuch as there are many chitosan formulations, thorough testing of each chitosan prior to its application is essential. Results obtained in glass tubes were similar to those from standard jar tests demonstrating that glass tube tests can be used for testing effects of coagulants and ballasts in cyanobacteria removal whilst allowing far more replicates. There was no relation between zeta potential and precipitated cyanobacteria. Given the well-known antibacterial activity of chitosan and recent findings of anti-cyanobacterial effects, pre-application tests are needed to decipher if chitosan may cause cell leakage of cyanotoxins. Efficiency- and side-effect testing are crucial for water managers to determine if the selected approach can be used in tailor-made interventions to control cyanobacterial blooms and to mitigate eutrophication. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Application of alum and chickpea (cicer arietinum) in removing color from leachate

    NASA Astrophysics Data System (ADS)

    Zin, N. S. M.; Awang, N. H.; Akbar, N. A.

    2018-04-01

    Dual coagulant has the potential to improve the coagulation process. In leachate treatment coagulation/flocculation can be used as a main treatment method or as a polishing/tertiary treatment step. Application of natural coagulant as coagulant aids able to increase the formation of floc and the removal ability of the coagulation process. This study was focusing on the ability of dual coagulants made from chemical coagulant (Alum) and natural coagulant (Cicer Arietinum (CA)) in removing colour from leachate. Jar test was carried out to investigate the effect of dose and pH on the removal ability of the dual coagulant. The optimum pH and dose for dual coagulant were obtained at pH 6.0 with dose of Alum at 4 g/L and dose of CA at 0.6 g/L with 94% removal of colour. While the optimum removal of colour for single Alum (4 g/L) and single CA (1.4 g/L) were recorded as 88% and 22%, respectively. The removals obtained using single natural and chemical coagulants were not as good as those obtained by dual coagulant. Thus, addition of CA as a coagulant aid for alum, able to increase the removal of color from leachate and has the potential to be applied as a treatment method for leachate.

  9. Overview of the coagulation system.

    PubMed

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-09-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.

  10. Overview of the coagulation system

    PubMed Central

    Palta, Sanjeev; Saroa, Richa; Palta, Anshu

    2014-01-01

    Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ‘coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same. PMID:25535411

  11. Opposite effects of Agrimonia pilosa Ledeb aqueous extracts on blood coagulation function

    PubMed Central

    Yuan, Wufeng; Jiang, Lei; Wang, Huan

    2017-01-01

    Background Agrimonia pilosa Ledeb (APL) has showed anticoagulant and antithrombotic activities in some studies, whereas its actual effects on blood coagulation are still unclear. This study was designed to observe the in vitro effects of APL aqueous extracts on blood coagulation, as well as to investigate the underlying mechanisms. Methods Studies were divided into four groups: 0, 4, 20, and 80 g/L of APL aqueous extracts mixed with plasma or whole blood samples. Clotting time of whole blood, plasma coagulation tests, activities of plasma coagulation factors, plasma calcium ion, platelet aggregation test, and platelet fibrinogen receptor as well as the blood viscosity were measured. Results It was observed that the APL aqueous extracts in 4 g/L significantly prolonged the whole blood clotting time and activated partial thromboplastin time, shortened prothrombin time, decreased activities of coagulation factor VIII, IX and XI, and levels of platelet aggregation and fibrinogen receptor expression. However, coagulation factor VII activity, and blood viscosity were increased after the extracts treatment. And the effects of APL extracts were in a concentration-dependent manner (0–80 g/L). Conclusions The results suggest that APL aqueous extracts have a total anticoagulant activity, whereas they exhibit opposite effects of greater anticoagulant activity than pro-coagulant activity. PMID:28480193

  12. Economic aspects of intraoperative coagulation management targeting higher fibrinogen concentrations during major craniosynostosis surgery.

    PubMed

    Haas, Thorsten; Spielmann, Nelly; Restin, Tanja; Schmidt, Alexander R; Schmugge, Markus; Cushing, Melissa M

    2016-01-01

    Results of a previously published study demonstrated a significant decrease in transfusion requirements and calculated blood loss for pediatric major craniosynostosis surgery, if a ROTEM(®) FIBTEM trigger of <13 mm (early substitution group) was applied as compared to a trigger of <8 mm (conventional group). The aim of this study was a posthoc analysis of the costs for this coagulation management. The total volume as well as the number of units or bags for all transfused blood products and coagulation factors were recorded for each case. The number of laboratory and point-of-care coagulation tests was also analyzed. Total blood product costs were calculated according to the local prices per unit. The total cost for all transfused/administered blood products/coagulation factors per patient was a median of 1023EUR (IQR 850EUR-1058EUR) in the early substitution group as compared to a median of 910EUR (IQR 719EUR-1351EUR) in the conventional group (P = 0.81). No difference in the number of coagulation tests performed was observed. In this study, the use of a higher fibrinogen trigger was not linked to a significant increase in total costs for transfused blood products and coagulation factors, and may offer an economically equivalent approach to coagulation management. © 2015 John Wiley & Sons Ltd.

  13. [Reference values for the blood coagulation tests in Mexico: usefulness of the pooled plasma from blood donors].

    PubMed

    Calzada-Contreras, Adriana; Moreno-Hernández, Manuel; Castillo-Torres, Noemi Patricia; Souto-Rosillo, Guadalupe; Hernández-Juárez, Jesús; Ricardo-Moreno, María Tania; Sánchez-Fernández, Maria Guadalupe de Jesús; García-González, América; Majluf-Cruz, Abraham

    2012-01-01

    The blood coagulation system maintains the blood in a liquid state and bleeding and thrombosis are the manifestations of its malfunction. Blood coagulation laboratory evaluates the physiology of this system. To establish both, the reference values for several tests performed at the blood coagulation laboratory as well as the utility of the pooled plasma to perform these assays. MATERIAL AND: In this descriptive, cross-sectional, randomized study, we collected plasma from Mexican Mestizos. Each pooled plasma was prepared with the plasma from at least 20 blood donors. We performed screening and special tests and the Levey-Jennings graphs were built and interpreted after each pass. Results of the tests were analyzed and their distribution was established using the Kolmogorov-Smirnov test. To establish the reference values we used 95% confidence intervals. We collected 72 pooled plasmas. The distribution for PT, APTT, and TT tests was abnormal. Although the PT test showed a bimodal distribution it was normal for factor VII. The reference values for the hemostatic, anticoagulant, and fibrinolytic factors were different from those suggested by the manufacturers. We established the reference values for the blood coagulation tests in the adult Mexican population. We have shown that the pooled plasma must be used for the screening tests. We suggest that each clinical laboratory should establish its own reference values (at least for the screening tests). To reach this objective, we encourage the use of the pooled plasma.

  14. Preanalytical influence of pneumatic tube delivery system on results of routine biochemistry and haematology analysis.

    PubMed

    Petit, Morgane; Mine, Louis; Pascreau, Tiffany; Brouzes, Chantal; Majoux, Sandrine; Borgel, Delphine; Beaudeux, Jean-Louis; Lasne, Dominique; Hennequin, Carole

    2017-12-01

    Pneumatic tube delivery system (PTS) enables to reduce considerably turnaround times. The aim of the study was to assess the influence of the PTS on the quality of routine biochemical and hematological tests in our laboratory. Blood samples from 6 hospitalized patients and 8 healthy volunteers were analyzed. Blood samples were delivered to the laboratory by a PTS and by a human courier. We performed the following analysis: ionized calcium, sodium, potassium, lactate deshydrogenase (LDH), aspartate aminotransferase (ASAT), arterial blood gas, complete blood count and coagulation test as prothrombin time, activated partial thromboplastin time, factors V and VIII. Results were compared between the both method of transport according to the recommendation of the Société française de biologie clinique and the French committee for accreditation (SH-GTA01, norme NF ISO 5275-6). The hemolysis index of plasma was similar between the groups and no morphological differences were found on blood cells. For three samples, when delivered by PTS, LDH levels (two samples) and neutrophil polynuclear count (one sample) were above the recommended guidelines compared to those delivered by courier. Conversely, LDH levels and FVIII were below in two samples delivered by PTS. LDH levels, PNN count or factor VIII can be affected by PTS without the clinical interpretation being modified. We concluded that the PTS can be used to transport blood samples for routine biochemical and hematological analysis in our hospital.

  15. Application of low-mixing energy input for the coagulation process.

    PubMed

    Vadasarukkai, Yamuna S; Gagnon, Graham A

    2015-11-01

    Rapid-mixing tanks with mechanical mixers are a common design used in treatment plants. Yet, the role of such rapid-mixing systems on the effectiveness of the coagulation performance is unclear. This study looked at optimizing the direct energy used in the coagulation process for removal of natural dissolved organic matter (DOM). The role of coagulation mixing intensity (G-value) on total organic carbon (TOC) and turbidity removal was examined for the water types with high organic content, with a specific ultraviolet absorbance (SUVA) of at least 2-2.5 units of m(-1) of absorbance per mg/L. A standard jar test using ferric sulfate coagulant was performed to optimize the chemical condition in coagulation for removal of dissolved organics as well as particles. The jar test analysis at an acidic pH (4.5 ± 0.3) required an iron dose <0.3 mM to arrive at an optimal coagulant concentration and resulted in above 75% of TOC removal. The influence of coagulation mixing on TOC and turbidity removal was evaluated at G varying from 0 to 1500 s(-1) at the optimized coagulant dose and pH conditions for enhanced coagulation. In this study, a combined effective removal of TOC and turbidity was achieved at a low-mixing intensity range of 110 s(-1) < G < 450 s(-1). Coagulation operated at G greater than 450 s(-1) showed negligible improvement in TOC removal. Minimizing energy consumption in enhanced coagulation is feasible at the proposed mixing intensity range (i.e., 110 s(-1) < G < 450 s(-1)), without sacrificing the effectiveness of DOM removal by coagulation. These findings represent an opportunity for energy savings for the water industry without sacrificing quality. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. [Point-of-care Coagulation Testing in Neurosurgery].

    PubMed

    Adam, Elisabeth Hannah; Füllenbach, Christoph; Lindau, Simone; Konczalla, Jürgen

    2018-06-01

    Disorders of the coagulation system can seriously impact the clinical course and outcome of neurosurgical patients. Due to the anatomical location of the central nervous system within the closed skull, bleeding complications can lead to devastating consequences such as an increase in intracranial pressure or enlargement of intracranial hematoma. Point-of-care (POC) devices for the testing of haemostatic parameters have been implemented in various fields of medicine. Major advantages of these devices are that results are available quickly and that analysis can be performed at the bedside, directly affecting patient management. POC devices allow identification of increased bleeding tendencies and therefore may enable an assessment of hemorrhagic risks in neurosurgical patients. Although data regarding the use of POC testing in neurosurgical patients are limited, they suggest that coagulation testing and hemostatic therapy using POC devices might have beneficial effects in this patient population. This article provides an overview of the application of point-of-care coagulation testing in clinical practice in neurosurgical patients. Georg Thieme Verlag KG Stuttgart · New York.

  17. Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system.

    PubMed

    Wang, Yili; Guo, Jinlong; Tang, Hongxiao

    2002-01-01

    Factors of pretreatment coagulation/flocculation units were studied using raw water of low temperature and low turbidity. Aluminum sulfate (AS) and selected polyaluminium chlorides (PACls) were all effective in the DAF process when used under favorable conditions of coagulant addition, coagulation, flocculation and flotation units. Compared with the AS coagulant, PACls, at lower dosage, could give the same effective performance even with shorter coagulation/flocculation time or lower recycle ratio during the treatment of cold water. This is attributed to the higher-charged polymeric Al species, and the lower hydrophilic and more compact flocculated flocs of PACl coagulant. Based on results of pilot experiments, the goal of FRD system can be achieved by combining a DAF heterocoagulation reactor with PACl coagulant (F), an efficient flocculation reactor (R), as well as an economical auto-dosing system (D).

  18. Particle counter as a tool to control pre-hydrolyzed coagulant dosing and rapid filtration efficiency in a conventional treatment system.

    PubMed

    Gumińska, Jolanta; Kłos, Marcin

    2015-01-01

    Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.

  19. Interpretation of coagulation test results using a web-based reporting system.

    PubMed

    Quesada, Andres E; Jabcuga, Christine E; Nguyen, Alex; Wahed, Amer; Nedelcu, Elena; Nguyen, Andy N D

    2014-01-01

    Web-based synoptic reporting has been successfully integrated into diverse fields of pathology, improving efficiency and reducing typographic errors. Coagulation is a challenging field for practicing pathologists and pathologists-in-training alike. To develop a Web-based program that can expedite the generation of a individualized interpretive report for a variety of coagulation tests. We developed a Web-based synoptic reporting system composed of 119 coagulation report templates and 38 thromboelastography (TEG) report templates covering a wide range of findings. Our institution implemented this reporting system in July 2011; it is currently used by pathology residents and attending pathologists. Feedback from the users of these reports have been overwhelmingly positive. Surveys note the time saved and reduced errors. Our easily accessible, user-friendly, Web-based synoptic reporting system for coagulation is a valuable asset to our laboratory services. Copyright© by the American Society for Clinical Pathology (ASCP).

  20. Real-Time Electrical Impedimetric Monitoring of Blood Coagulation Process under Temperature and Hematocrit Variations Conducted in a Microfluidic Chip

    PubMed Central

    Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming

    2013-01-01

    Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099

  1. Thromboelastometry versus standard coagulation tests versus restrictive protocol to guide blood transfusion prior to central venous catheterization in cirrhosis: study protocol for a randomized controlled trial.

    PubMed

    Rocha, Leonardo Lima; Pessoa, Camila Menezes Souza; Neto, Ary Serpa; do Prado, Rogerio Ruscitto; Silva, Eliezer; de Almeida, Marcio Dias; Correa, Thiago Domingos

    2017-02-27

    Liver failure patients have traditionally been empirically transfused prior to invasive procedures. Blood transfusion is associated with immunologic and nonimmunologic reactions, increased risk of adverse outcomes and high costs. Scientific evidence supporting empirical transfusion is lacking, and the best approach for blood transfusion prior to invasive procedures in cirrhotic patients has not been established so far. The aim of this study is to compare three transfusion strategies (routine coagulation test-guided - ordinary or restrictive, or thromboelastometry-guided) prior to central venous catheterization in critically ill patients with cirrhosis. Design and setting: a double-blinded, parallel-group, single-center, randomized controlled clinical trial in a tertiary private hospital in São Paulo, Brazil. adults (aged 18 years or older) admitted to the intensive care unit with cirrhosis and an indication for central venous line insertion. Patients will be randomly assigned to three groups for blood transfusion strategy prior to central venous catheterization: standard coagulation tests-based, thromboelastometry-based, or restrictive. The primary efficacy endpoint will be the proportion of patients transfused with any blood product prior to central venous catheterization. The primary safety endpoint will be the incidence of major bleeding. Secondary endpoints will be the proportion of transfusion of fresh frozen plasma, platelets and cryoprecipitate; infused volume of blood products; hemoglobin and hematocrit before and after the procedure; intensive care unit and hospital length of stay; 28-day and hospital mortality; incidence of minor bleeding; transfusion-related adverse reactions; and cost analysis. This study will evaluate three strategies to guide blood transfusion prior to central venous line placement in severely ill patients with cirrhosis. We hypothesized that thromboelastometry-based and/or restrictive protocols are safe and would significantly reduce transfusion of blood products in this population, leading to a reduction in costs and transfusion-related adverse reactions. In this manner, this trial will add evidence in favor of reducing empirical transfusion in severely ill patients with coagulopathy. ClinicalTrials.gov, identifier: NCT02311985 . Retrospectively registered on 3 December 2014.

  2. [Evaluation of coagulation disorders with thrombelastography in patients with sepsis].

    PubMed

    Zhong, Shengjian; Zhang, Chunbao; Hu, Juntao; Tang, Zhanhong

    2016-02-01

    To compare the results of thrombelastography (TEG) and the conventional coagulability test in patients with sepsis, and to discuss the value of TEG in monitoring blood coagulation dysfunction in patients with sepsis. The clinical data of 92 adult patients with sepsis admitted to Department of Critical Care Medicine of the First Affiliated Hospital of Guangxi Medical University were retrospectively analyzed. The patients were divided into sequential organ failure assessment (SOFA) score ≥ 12 group (n = 47) and SOFA < 12 group (n = 45). Thirty-five non-sepsis adult patients with normal coagulation function served as control group. The venous blood was collected for conventional blood coagulation test and routine examination of blood, D-dimer, procalcitonin (PCT), and TEG, and the differences were compared among three groups. Correlations between SOFA and various indexes of patients with sepsis were analyzed by Spearman rank correlation method. As shown in the results of the conventional blood coagulation test, D-dimer was gradually increased with the aggravation of the disease, the values in non-sepsis, SOFA < 12, and SOFA ≥ 12 groups were 0.523 (0.273, 0.928), 0.863 (0.673, 4.221), and 4.118 (2.420, 5.653) mg/L respectively (Z = 25.163, P = 0.000). Platelet count (PLT) in SOFA ≥ 12 group was significantly lower than that of the SOFA < 12 group and non-sepsis group [×10(9)/L: 28.6 (12.8, 48.9) vs. 257.3 (152.6, 339.8), 182.0 (118.0, 229.0), both P < 0.01]. There was no significant difference in prothrombin time (PT) and international normalized ratio (INR) among three groups, and it indicated that the conventional blood coagulation test might not respond quickly to the change in coagulation status of sepsis patients. As shown in the results of TEG, the values of reaction time (R value) and kinetics time (K value) in SOFA < 12 group were lower than those of the non-sepsis group [R value (minutes): 4.4 (3.6, 6.1) vs. 6.3 (6.0, 6.7), P < 0.01; K value (minutes): 1.1 (1.0, 1.5) vs. 1.5 (1.3, 1.8), P < 0.05], while they were higher in SOFA ≥ 12 group than those of the non-sepsis group [R value (minutes): 7.0 (5.7, 8.7) vs. 6.3 (6.0, 6.7), P > 0.05; K value (minutes): 4.2 (3.4, 7.1) vs. 1.5 (1.3, 1.8), P < 0.01]. The α angle, maximum amplitude (MA) and coagulation index (CI) in SOFA < 12 group were higher than those of the non-sepsis group [α angle (degree angle): 73.3 (68.5, 74.7) vs. 66.8 (62.2, 69.0), P < 0.01; MA (mm): 71.7 (61.9, 73.3) vs. 60.3 (58.2, 63.8), P < 0.01; CI: 3.1 (-0.1, 3.9) vs. 0.9 (-0.4, 1.3), P < 0.05], while they were lower in SOFA ≥ 12 group than those of the non-sepsis group [α angle (degree angle): 48.1 (36.6, 53.0) vs. 66.8 (62.2, 69.0), P < 0.01; MA (mm): 37.8 (30.0, 45.7) vs. 60.3 (58.2, 63.8), P < 0.01; CI: -5.6 (-8.4, -3.6) vs. 0.9 (-0.4, 1.3), P < 0.01]. The above results indicated that TEG could distinguish quickly the hypercoagulability and hypocoagulability status in septic patients. PCT in non-sepsis, SOFA < 12, and SOFA ≥ 12 groups were 0.27 (0.05, 1.80), 0.68 (0.10, 10.00), 41.10 (4.24, 100.00) μg/L respectively (Z = 195.475, P = 0.000), which indicate the severity of infectious disease. Correlation analysis results showed that SOFA score was negatively correlated with PLT, α angle, MA, and CI (r value was -0.853, -0.833, -0.881, and -0.859, respectively, all P = 0.000), and it was positively correlated with activated partial thromboplastin time (APTT), D-dimer, R value, K value, and PCT (r value was 0.381, 0.561, 0.587, 0.831, 0.775, respectively, P < 0.05 or P < 0.01), and non correlations was founded with PT, fibrinogen (FBG), and INR (r1 = 0.211, P1 = 0.233; r2 = -0.252, P2 = 0.142; r3 = 0.248, P3 = 0.148). TEG can effectively monitor the change in coagulation in patients with sepsis, and distinguish the hypercoagulable and hypocoagulable state. TEG may be a valuable tool to evaluate degree and risk of sepsis objectively.

  3. Two novel fibrinogen variants in the C-terminus of the Bβ-chain: fibrinogen Rokycany and fibrinogen Znojmo.

    PubMed

    Kotlín, Roman; Reicheltová, Zuzana; Suttnar, Jirí; Salaj, Peter; Hrachovinová, Ingrid; Riedel, Tomás; Malý, Martin; Oravec, Milan; Kvasnicka, Jan; Dyr, Jan Evangelista

    2010-10-01

    Hereditary dysfibrinogenemia is a rare disorder wherein an inherited abnormality in fibrinogen structure may result in defective fibrin function and/or structure. Congenital hypofibrinogenemia is a rare autosomal bleeding disorder, either recessive or dominant, characterized by a low fibrinogen plasma level. A 28-year-old asymptomatic woman (fibrinogen Rokycany) and a 54-year-old man with thrombosis and pulmonary embolism (fibrinogen Znojmo) were investigated for a suspected fibrinogen mutation after abnormal coagulation tests results were obtained. DNA sequencing showed the heterozygous point mutation Bβ Asn351Lys in fibrinogen Rokycany and the heterozygous point mutation Bβ Arg237Ser in fibrinogen Znojmo, respectively. The kinetics of fibrinopeptide release was found to be normal in both cases. Fibrinolysis was impaired in the Znojmo variant. The average fibril diameters of Znojmo fibrin was slightly increased, but not differing significantly from normal; formed by less fibrils with abrupt fibril terminations. Rheological studies revealed a softer clot. Rokycany fibrin was formed by significantly narrower fibrils than normal fibrin; and the clot was denser than the control clot. Rheological studies revealed a stiffer clot. Impaired fibrinolysis and abnormal clot morphology may be the cause of thrombotic episodes in the patient with Znojmo mutation. New cases of hypofibrinogenemia and dysfibrinogenemia, found by routine coagulation testing, were genetically identified as a novel fibrinogen variants Bβ Asn351Lys (fibrinogen Rokycany) and Bβ Arg237Ser (fibrinogen Znojmo), respectively.

  4. [The usefulness of routine laboratory tests in the evaluation of sudden threat of pregnant woman and fetus in pre-eclampsia].

    PubMed

    Malarewicz, Andrzej; Gruszka, Olga; Szymkiewicz, Jadwiga; Rogala, Jerzy

    2006-04-01

    The fact that the progress of pre-eclampsia is highly unpredictable is the reason to run necessary monitoring, among others, by means of laboratory tests. Their aim is to determine explicitly if the pregnancy can be continued and terminated naturally or should be terminated by pre-term induced delivery or Caesarean section. There is a wide range of laboratory investigations recommended in pregnancy complicated by pre-eclampsia. The results reported in the literature though are controversial and inexplicit. The purpose of the research was to verify routine lab tests results used in decision making for emergency termination of pregnancy as a result of increased threatening clinical symptoms and to evaluate their usefulness in decision making to start delivery. The investigation covered 152 women who were divided into three groups. One consisted of 62 pregnant women with light form of pre-eclampsia, the other of 24 pregnant women with severe form of pre-eclampsia. The control group consisted of 66 healthy pregnant women. All pregnant women with pre-eclampsia diagnosed delivered by Caesarean section. The decision to perform the operation was based on biophysical findings of the fetus. At the moment of decision-making, blood was drawn for laboratory testing of the following parameters: systemic blood, coagulation parameters, total protein and protein fractios, non-protein nitrogen blood components, glucose, electrolytes, indicating enzymes and excretory enzymes of protein metabolism, lipid fractions. Routine lab tests performed in pre-eclampsia do not indicate distinct abnormalities the moment fetus life threatening clinical symptoms occur that enforce the decision of immediate delivery, the exception are the indicating enzymes. Acute clinical symptoms that endanger fetus life in pre-eclampsia correlate with distinct activity of AspAT, AIAT and LDH. Laboratory tests are of no prognostic value in the prediction of sudden worsening of the fetus condition in pre-eclampsia.

  5. Influence of a constant and variable magnetic field on the coagulation of human blood in vitro and in vivo

    NASA Technical Reports Server (NTRS)

    Degen, I. L.; Plaksenko, V. Y.

    1974-01-01

    The influence of constant and varying magnetic fields on the coagulation of the blood was studied in experiments performed in vitro and vivo. In the in vitro tests it was found that a constant magnetic field with a strength of 100 or 200 oersteds influences the coagulation of the blood, retarding it in some cases and speeding up the coagulation time in others. In the in vivo studies, both retarding and accelerating effects were likewise observed with respect to the coagulation of the blood, but the nature of the change was a function of the background. A normalizing effect of the magnetic field on the coagulation of the blood was observed.

  6. Biochemical quality of the pharmaceutically licensed plasma OctaplasLG after implementation of a novel prion protein (PrPSc) removal technology and reduction of the solvent/detergent (S/D) process time.

    PubMed

    Heger, A; Svae, T-E; Neisser-Svae, A; Jordan, S; Behizad, M; Römisch, J

    2009-10-01

    A new chromatographic step for the selective binding of pathological prion proteins (PrP(Sc)) to an affinity ligand, developed and optimized for PrP(Sc) capture and attached to synthetic resin particles (PRDT, USA; ProMetic BioSciences Ltd, Isle of Man, UK) was implemented into the manufacturing process of the solvent/detergent (S/D) treated biopharmaceutical quality plasma Octaplas. Pilot batches of Octaplas with the implemented chromatographic step [labelled as OctaplasLG (ligand gel)] were manufactured by Octapharma PPGmbH, Vienna, Austria. The biochemical quality was compared directly after manufacturing as well as after 18 months storage. All samples were tested on global coagulation parameters, fibrinogen levels, activities of coagulation factors and protease inhibitors, ADAMTS13 levels, as well as markers of activated coagulation and fibrinolysis. In addition, von Willebrand factor multimeric analysis was performed. The incorporation of this novel chromatography into the large-scale routine manufacturing process was shown to be technically feasible and the performance of the column was assessed to be excellent. The biochemical studies showed that Octaplas and OctaplasLG produced without and with the new column, respectively, demonstrate an identical biochemical quality. OctaplasLG remained stable over a period of 18 months stored frozen. A parallel reduction of the S/D virus inactivation step from 4-4.5 to 1-1.5 h led to significantly higher activities of plasmin inhibitor. The studies confirmed that the affinity ligand chromatography under the developed conditions can be introduced into the Octaplas manufacturing process, as a mean to reduce potentially present PrP(Sc), without hampering the proven quality of this product.

  7. Cost-Effectiveness of POC Coagulation Testing Using Multiple Electrode Aggregometry.

    PubMed

    Straub, Niels; Bauer, Ekaterina; Agarwal, Seema; Meybohm, Patrick; Zacharowski, Kai; Hanke, Alexander A; Weber, Christian F

    2016-01-01

    The economic effects of Point-of-Care (POC) coagulation testing including Multiple Electrode Aggregometry (MEA) with the Multiplate device have not been examined. A health economic model with associated clinical endpoints was developed to calculate the effectiveness and estimated costs of coagulation analyses based on standard laboratory testing (SLT) or POC testing offering the possibility to assess platelet dysfunction using aggregometric measures. Cost estimates included pre- and perioperative costs of hemotherapy, intra- and post-operative coagulation testing costs, and hospitalization costs, including the costs of transfusion-related complications. Our model calculation using a simulated true-to-life cohort of 10,000 cardiac surgery patients assigned to each testing alternative demonstrated that there were 950 fewer patients in the POC branch who required any transfusion of red blood cells. The subsequent numbers of massive transfusions and patients with transfusion-related complications were reduced with the POC testing by 284 and 126, respectively. The average expected total cost in the POC branch was 288 Euro lower for every treated patient than that in the SLT branch. Incorporating aggregometric analyses using MEA into hemotherapy algorithms improved medical outcomes in cardiac surgery patients in the presented health economic model. There was an overall better economic outcome associated with POC testing compared with SLT testing despite the higher costs of testing.

  8. Optical profiling of anticoagulation status (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tshikudi, Diane M.; Tripathi, Markandey M.; Hajjarian, Zeinab; Nadkarni, Seemantini K.

    2016-02-01

    Defective blood coagulation resulting from excessive procoagulant activity often leads to thrombotic disorders such as stroke and myocardial infarction. A variety of oral and injectable anticoagulant drugs are prescribed to prevent or treat life-threatening thrombosis. However, due to bleeding complications often associated with anticoagulant treatment, routine monitoring and accurate dosing of anticoagulant therapy is imperative. We have developed Optical thromboelastography (OTEG), a non-contact approach that utilizes a drop of whole blood to measure blood coagulation status in patients. Here, we demonstrate the capability of OTEG for rapidly monitoring anticoagulation in whole blood samples. OTEG monitors coagulation status by assessing changes in blood viscosity from temporal intensity fluctuations of laser speckle patterns during clotting. In OTEG a blood drop is illuminated with coherent light and the blood viscosity is measured from the speckle intensity autocorrelation curve, g2 (t). The metrics, clotting time (R+k), clot progression (angle) and maximum clot stiffness (MA) are then extracted. The aim of the current study was to evaluate the accuracy of OTEG in assessing anticoagulation status of common anticoagulants including heparin, argatroban and rivaroxaban status. A dose-dependent prolongation of R+k was observed in anticoagulated blood, which closely corresponded with standard-reference Thromboelastography (TEG) (r 0.87-0.99, P>0.01 for all cases). OTEG angle was unaltered by anticoagulation whereas TEG angle presented a dose-dependent diminution probably linked to clot rupture. In both OTEG and TEG, MA was unaffected by heparin, argatroban or rivaroxaban. We conclude that OTEG can accurately monitor anticoagulation status following treatment, potentially providing a powerful tool for routine monitoring of patients in the doctor's office or in the home setting.

  9. Effects of Oritavancin on Coagulation Tests in the Clinical Laboratory.

    PubMed

    Belley, Adam; Robson, Richard; Francis, John L; Adcock, Dorothy M; Tiefenbacher, Stefan; Rubino, Christopher M; Moeck, Greg; Sylvester, David; Dudley, Michael N; Loutit, Jeffery

    2017-02-01

    Previous studies have shown that some lipoglycopeptide and lipopeptide antimicrobial agents may cause falsely elevated values for some phospholipid-dependent coagulation tests. The effect of oritavancin, a lipoglycopeptide antibiotic, on coagulation test results was explored using pooled human plasma samples spiked with drug and in a clinical study after an infusion of a single 1,200-mg intravenous dose of oritavancin in normal healthy volunteers. Pooled plasma with oritavancin added ex vivo showed concentration-dependent prolongation of prothrombin time/international normalized ratio (PT/INR), activated partial thromboplastin time (aPTT), and dilute Russell viper venom time (DRVVT) test results. In contrast, oritavancin had no effect on the activated protein C resistance assay, chromogenic anti-factor Xa assay (anti-FXa), thrombin time, and an immunoassay for the laboratory diagnosis of heparin-induced thrombocytopenia. In participants that received a single dose of oritavancin, elevations in PT/INR result, aPTT, DRVVT, activated clotting time, and silica clotting time occurred, with the maximum times to resolution of test interference determined to be 12, 120, 72, 24, and 18 h, respectively. The anti-FXa assay was unaffected, whereas transient elevations in D dimer levels were observed in 30% of participants, with a maximum time to resolution of 72 h. Although oritavancin has no impact on the coagulation system in vivo, a single dose of oritavancin can produce falsely elevated values of some coagulation tests used to monitor hemostasis. The interference of oritavancin on affected tests is transient, and the test results revert to normal ranges within specified times after dosing. Copyright © 2017 American Society for Microbiology.

  10. Effects of Oritavancin on Coagulation Tests in the Clinical Laboratory

    PubMed Central

    Robson, Richard; Francis, John L.; Adcock, Dorothy M.; Tiefenbacher, Stefan; Rubino, Christopher M.; Moeck, Greg; Sylvester, David; Dudley, Michael N.; Loutit, Jeffery

    2016-01-01

    ABSTRACT Previous studies have shown that some lipoglycopeptide and lipopeptide antimicrobial agents may cause falsely elevated values for some phospholipid-dependent coagulation tests. The effect of oritavancin, a lipoglycopeptide antibiotic, on coagulation test results was explored using pooled human plasma samples spiked with drug and in a clinical study after an infusion of a single 1,200-mg intravenous dose of oritavancin in normal healthy volunteers. Pooled plasma with oritavancin added ex vivo showed concentration-dependent prolongation of prothrombin time/international normalized ratio (PT/INR), activated partial thromboplastin time (aPTT), and dilute Russell viper venom time (DRVVT) test results. In contrast, oritavancin had no effect on the activated protein C resistance assay, chromogenic anti-factor Xa assay (anti-FXa), thrombin time, and an immunoassay for the laboratory diagnosis of heparin-induced thrombocytopenia. In participants that received a single dose of oritavancin, elevations in PT/INR result, aPTT, DRVVT, activated clotting time, and silica clotting time occurred, with the maximum times to resolution of test interference determined to be 12, 120, 72, 24, and 18 h, respectively. The anti-FXa assay was unaffected, whereas transient elevations in D dimer levels were observed in 30% of participants, with a maximum time to resolution of 72 h. Although oritavancin has no impact on the coagulation system in vivo, a single dose of oritavancin can produce falsely elevated values of some coagulation tests used to monitor hemostasis. The interference of oritavancin on affected tests is transient, and the test results revert to normal ranges within specified times after dosing. PMID:27956417

  11. Thymoquinone Modulates Blood Coagulation in Vitro via Its Effects on Inflammatory and Coagulation Pathways

    PubMed Central

    Muralidharan-Chari, Vandhana; Kim, Jaehan; Abuawad, Ahlam; Naeem, Mubeena; Cui, Huadong; Mousa, Shaker A.

    2016-01-01

    Thymoquinone (THQ) is a major component of black seeds. Given that both THQ and black seeds exhibit anti-cancer and anti-inflammatory activities, we hypothesized that THQ will affect cancer-associated thrombosis (CAT), which is primarily triggered by tissue factor (TF) and inflammation. The effect of both black seed-extracted and purchased (“pure”) THQ on normal blood coagulation was tested with in vitro thromboelastography (TEG) and activated partial thromboplastin time (aPTT) coagulation assays. The effect of pure THQ on CAT was tested with aPTT assay using pancreatic cancer cell lines that are either positive or negative for TF, and with TEG assay using lipopolysaccharide as an inflammatory trigger. Additionally, the direct effect of THQ on the inactivation of factors IIa and Xa was assessed. Since TNF-α facilitates crosstalk between inflammation and thrombosis by triggering the NF-κB pathway, we tested THQ’s ability to interfere with this communication with a luciferase assay. Both extracted and pure THQ had minimal effects on normal blood coagulation. Pure THQ reversed CAT initiated by both TF and inflammation to basal levels (p < 0.001). Mechanistically, while THQ had minimal to no effect on factor IIa and Xa inactivation, it strongly reduced the effects of TNF-α on NF-κB elements (p < 0.001). THQ has a minimal effect on basal coagulation and can reverse CAT in vitro, possibly by interfering with the crosstalk between inflammation and coagulation. This study suggests the utility of THQ as a preventative anticoagulant and/or as a supplement to existing chemotherapies and anticoagulant therapies. PMID:27043539

  12. 21 CFR 864.7750 - Prothrombin time test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the detection of possible clotting factor deficiencies in the extrinsic coagulation pathway, which involves the reaction between coagulation factors III and VII, and to monitor patients receiving coumarin...

  13. Comparison of Moringa stenopetala seed extract as a clean coagulant with Alum and Moringa stenopetala-Alum hybrid coagulant to remove direct dye from Textile Wastewater.

    PubMed

    Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein

    2016-08-01

    In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.

  14. Reduction of Turbidity of Water Using Locally Available Natural Coagulants

    PubMed Central

    Asrafuzzaman, Md.; Fakhruddin, A. N. M.; Hossain, Md. Alamgir

    2011-01-01

    Turbidity imparts a great problem in water treatment. Moringa oleifera, Cicer arietinum, and Dolichos lablab were used as locally available natural coagulants in this study to reduce turbidity of synthetic water. The tests were carried out, using artificial turbid water with conventional jar test apparatus. Optimum mixing intensity and duration were determined. After dosing water-soluble extracts of Moringa oleifera, Cicer arietinum, and Dolichos lablab reduced turbidity to 5.9, 3.9, and 11.1 nephelometric turbidity unit (NTU), respectively, from 100 NTU and 5, 3.3, and 9.5, NTU, respectively, after dosing and filtration. Natural coagulants worked better with high, turbid, water compare to medium, or low, turbid, water. Highest turbidity reduction efficiency (95.89%) was found with Cicer arietinum. About 89 to 96% total coliform reduction were also found with natural coagulant treatment of turbid water. Using locally available natural coagulants, suitable, easier, and environment friendly options for water treatment were observed. PMID:23724307

  15. Measurement of blood coagulation with considering RBC aggregation through a microchip-based light transmission aggregometer.

    PubMed

    Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun

    2011-01-01

    Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.

  16. Principles of dielectric blood coagulometry as a comprehensive coagulation test.

    PubMed

    Hayashi, Yoshihito; Brun, Marc-Aurèle; Machida, Kenzo; Nagasawa, Masayuki

    2015-10-06

    Dielectric blood coagulometry (DBCM) is intended to support hemostasis management by providing comprehensive information on blood coagulation from automated, time-dependent measurements of whole blood dielectric spectra. We discuss the relationship between the series of blood coagulation reactions, especially the aggregation and deformation of erythrocytes, and the dielectric response with the help of clot structure electron microscope observations. Dielectric response to the spontaneous coagulation after recalcification presented three distinct phases that correspond to (P1) rouleau formation before the onset of clotting, (P2) erythrocyte aggregation and reconstitution of aggregates accompanying early fibrin formation, and (P3) erythrocyte shape transformation and/or structure changes within aggregates after the stable fibrin network is formed and platelet contraction occurs. Disappearance of the second phase was observed upon addition of tissue factor and ellagic acid for activation of extrinsic and intrinsic pathways, respectively, which is attributable to accelerated thrombin generation. A series of control experiments revealed that the amplitude and/or quickness of dielectric response reflect platelet function, fibrin polymerization, fibrinolysis activity, and heparin activity. Therefore, DBCM sensitively measures blood coagulation via erythrocytes aggregation and shape changes and their impact on the dielectric permittivity, making possible the development of the battery of assays needed for comprehensive coagulation testing.

  17. Physical and oxidative removal of organics during Fenton treatment of mature municipal landfill leachate.

    PubMed

    Deng, Yang

    2007-07-19

    Municipal landfill leachate, especially mature leachate, may disrupt the performance of moderately-sized municipal activated sludge wastewater treatment plants, and likewise tend to be recalcitrant to biological pretreatment. Recently, Fenton methods have been investigated for chemical treatment or pre-treatment of mature leachate. In this paper, the results of laboratory tests to determine the roles of oxidation and coagulation in reducing the organic content of mature leachate during Fenton treatment are presented. The efficiencies of chemical oxygen demand (COD) oxidation and coagulation were tested, and the ratio of COD removal by oxidation to that by coagulation was assessed, under various operating conditions. Low initial pH, appropriate relative and absolute Fenton reagent dosages, aeration, and stepwise addition of reagents increased COD removal by oxidation and the importance of oxidation relative to coagulation. Simultaneous aeration and stepwise reagent addition allowed comparable treatment without initial acidification pH, due to the generation of acidic organic intermediates and the continuous input of CO2. On the other hand, high COD oxidation efficiency and low ferrous dosage inhibited COD removal by coagulation. At significantly high oxidation efficiency, overall COD reduction decrease slightly due to low coagulation efficiency. Under the most favorable conditions (initial pH 3, molar ratio [H(2)O(2)]/[Fe2+]=3, [H2O2]=240 mM, and six dosing steps), 61% of the initial COD was removed, and the ratio of COD removal oxidation to coagulation was 0.75. Results highlighted the synergistic roles of oxidation and coagulation in Fenton treatment of mature leachate, and the role of oxidation in controlling the efficiency of removal of COD by coagulation.

  18. Vitamin K supplementation for cystic fibrosis.

    PubMed

    Jagannath, Vanitha A; Fedorowicz, Zbys; Thaker, Vidhu; Chang, Anne B

    2011-01-19

    Cystic fibrosis is a genetic disorder which can lead to multiorgan dysfunction. Malabsorption of fat and fat-soluble vitamins (A, D, E, K) may occur and can cause subclinical deficiencies of some of these vitamins. Vitamin K is known to play an important role in both blood coagulation and bone formation. Supplementation with vitamin K appears to be one way of addressing the deficiency, but there is very limited agreement on the appropriate dose and frequency of use of these supplements. To assess the effects of vitamin K supplementation in people with cystic fibrosis and to determine the optimal dose and route of administration of vitamin K for both routine and therapeutic use. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group's Trials Register comprising references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Most recent search: 15 April 2010. Randomised and quasi-randomised controlled trials of all preparations of vitamin K used as a supplement compared to either no supplementation (or placebo) at any dose or route and for any duration, in children or adults diagnosed with cystic fibrosis (by sweat test or genetic testing). Two authors independently screened papers, extracted trial details and assessed their risk of bias. Two trials (total of 32 participants) were included in the review and were assessed as having a moderate risk of bias. One was a dose-ranging parallel group trial; and the other had a cross-over design, but no separate data were reported for the first intervention period. Neither of the trials addressed any of the primary outcomes (coagulation, bone formation and quality of life). Both trials reported the restoration of serum vitamin K and undercarboxylated osteocalcin levels to the normal range after one month of daily supplementation with 1 mg of vitamin K. Evidence from randomised controlled trials on the benefits of routine vitamin K supplementation for people with CF is currently weak and limited to two small trials of short duration. However, no harm was found and until further evidence is available, the present recommendations should be adhered to.

  19. Vitamin K supplementation for cystic fibrosis.

    PubMed

    Jagannath, Vanitha A; Fedorowicz, Zbys; Thaker, Vidhu; Chang, Anne B

    2013-04-30

    Cystic fibrosis is a genetic disorder which can lead to multiorgan dysfunction. Malabsorption of fat and fat-soluble vitamins (A, D, E, K) may occur and can cause subclinical deficiencies of some of these vitamins. Vitamin K is known to play an important role in both blood coagulation and bone formation. Supplementation with vitamin K appears to be one way of addressing the deficiency, but there is very limited agreement on the appropriate dose and frequency of use of these supplements. To assess the effects of vitamin K supplementation in people with cystic fibrosis and to determine the optimal dose and route of administration of vitamin K for both routine and therapeutic use. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group's Trials Register comprising references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Most recent search: 11 October 2012. Randomised and quasi-randomised controlled trials of all preparations of vitamin K used as a supplement compared to either no supplementation (or placebo) at any dose or route and for any duration, in children or adults diagnosed with cystic fibrosis (by sweat test or genetic testing). Two authors independently screened papers, extracted trial details and assessed their risk of bias. Two trials (total of 32 participants) were included in the review and were assessed as having a moderate risk of bias. One was a dose-ranging parallel group trial; and the other had a cross-over design, but no separate data were reported for the first intervention period. Neither of the trials addressed any of the primary outcomes (coagulation, bone formation and quality of life). Both trials reported the restoration of serum vitamin K and undercarboxylated osteocalcin levels to the normal range after one month of daily supplementation with 1 mg of vitamin K. Evidence from randomised controlled trials on the benefits of routine vitamin K supplementation for people with CF is currently weak and limited to two small trials of short duration. However, no harm was found and until further evidence is available, the present recommendations should be adhered to.

  20. Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

    PubMed

    Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta

    2013-05-01

    Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P < 0.005), with less prolongation in patient samples. TT results (Dabi) and calibrated anti-Xa results (Riva) were reported by only 11 and 8 laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.

  1. Fibrinopeptide A blood test

    MedlinePlus

    ... problems with blood clotting such as disseminated intravascular coagulation ( DIC ). Certain types of leukemia are associated with ... be a sign of: Cellulitis DIC (disseminated intravascular coagulation) Leukemia at the time of diagnosis, during early ...

  2. Decolorization and COD reduction of dyeing wastewater from a cotton textile mill using thermolysis and coagulation.

    PubMed

    Kumar, Pradeep; Prasad, B; Mishra, I M; Chand, Shri

    2008-05-01

    The decolorization and reduction of COD of dyeing wastewater from a cotton textile mill was conducted using catalytic thermal treatment (thermolysis) accompanied with/without coagulation. Thermolysis in presence of a homogeneous copper sulphate catalyst was found to be the most effective in comparison to other catalysts (FeCl(3), FeSO(4), CuO, ZnO and PAC) used. A maximum reduction of chemical oxygen demand (COD) and color of dyeing wastewater of 66.85% and 71.4%, respectively, was observed with a catalyst concentration of 5 kg/m(3) at pH 8. Commercial alum was found most effective coagulant among various coagulants (aluminum potassium sulphate, PAC, FeCl(3) and FeSO(4)) tested during coagulation operations, resulting in 58.57% COD and 74% color reduction at pH 4 and coagulant dose of 5 kg/m(3). Coagulation of the clear fluid (supernatant) obtained after treatment by thermolysis at the conditions previously used resulted in an overall reduction of 89.91% COD and 94.4% color at pH 4 and a coagulant dose of 2 kg/m(3). The application of thermolysis followed by coagulation, thus, is the most effective treatment method in removing nearly 90% COD and 95% color at a lower dose of coagulant (2 kg/m(3)). The sludge thus produced would contain lower inorganic mass coagulant and, therefore, less amount of inorganic sludge.

  3. Analysis and optimization of coagulation and flocculation process

    NASA Astrophysics Data System (ADS)

    Saritha, V.; Srinivas, N.; Srikanth Vuppala, N. V.

    2017-03-01

    Natural coagulants have been the focus of research of many investigators through the last decade owing to the problems caused by the chemical coagulants. Optimization of process parameters is vital for the effectiveness of coagulation process. In the present study optimization of parameters like pH, dose of coagulant and mixing speed were studied using natural coagulants sago and chitin in comparison with alum. Jar test apparatus was used to perform the coagulation. The results showed that the removal of turbidity was up to 99 % by both alum and chitin at lower doses of coagulant, i.e., 0.1-0.3 g/L, whereas sago has shown a reduction of 70-100 % at doses of 0.1 and 0.2 g/L. The optimum conditions observed for sago were 6 and 7 whereas chitin was stable at all pH ranges, lower coagulant doses, i.e., 0.1-0.3 g/L and mixing speed—rapid mixing at 100 rpm for 10 min and slow mixing 20 rpm for 20 min. Hence, it can be concluded that sago and chitin can be used for treating water even with large seasonal variation in turbidity.

  4. A new inorganic-organic composite coagulant, consisting of polyferric sulphate (PFS) and polyacrylamide (PAA).

    PubMed

    Moussas, P A; Zouboulis, A I

    2009-08-01

    Currently, research is focused on the synthesis of new composite coagulants, which are constituted of both inorganic and organic materials. In this paper, the development of relevant reagents was investigated, by combining the inorganic pre-polymerised iron-based coagulant Polyferric Sulphate (PFS) with an organic, non-ionic polymer (Polyacrylamide, PAA) under different PAA/Fe (mg/l) and OH/Fe molar ratios. Moreover, the new reagents were characterised in terms of typical properties, stability and morphological analysis (XRD, FTIR, SEM). Their coagulation performance, when treating low or high turbid kaolin-humic acid suspensions, was also investigated, whereas the applied coagulation mechanisms were discussed by using the Photometric Dispersion Analysis (PDA) analysis. The results show that the new coagulation reagents present improved properties, including increased effective polymer species concentration, and they exhibit very good stability. The respective tests using PDA confirmed that the predominant coagulation mechanism of PFS-PAA is the bridge formation mechanism. Coagulation experiments in low or high turbid kaolin-humic acid suspensions reveal that the novel composite reagent PFS-PAA exhibits better coagulation performance, when compared with simple PFS, in terms of zeta-potential reduction, turbidity and organic matter removal and residual iron concentration.

  5. New models of hemostasis.

    PubMed

    McMichael, Maureen

    2012-05-01

    Hemostasis is an essential protective mechanism that depends on a delicate balance of procoagulant and anticoagulant processes. The waterfall/cascade models of coagulation are useful for understanding several essential steps of coagulation in vitro. These have resulted in the creation of the plasma-based tests used commonly and the ability to identify deficiencies in the extrinsic, intrinsic, and common pathways of coagulation. The model was also essential in elucidating the role of several of the inhibitors of coagulation and is currently used to demonstrate coagulation as it occurs in plasma in a static environment that is devoid of endothelial interactions. The intrinsic pathway originally described by these models does not appear to be essential for in vivo hemostasis but may play a role in pathologic thrombosis. The waterfall/cascade models' lack of cellular elements sets the stage for the cell-based model of coagulation. The cell-based model of blood coagulation, which includes the varied, complicated network of factors necessary for appropriate in vivo coagulation to occur, was the next step in the evolution of our understanding of coagulation. Recently, researchers have focused on real-time, in vivo models of hemostasis and this research reveals unexpected phenomena. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Anticoagulant management in the cardiovascular setting.

    PubMed

    Verheugt, Freek W A

    2012-02-01

    Vitamin K antagonists have been used as oral anticoagulants (OACs) for over five decades, yet their use in real-world practice is problematic primarily because of their narrow therapeutic window, exacerbated by extensive food and drug interactions, necessitating regular coagulation monitoring and dose adjustment. Around half of patients receiving warfarin are within the therapeutic range, exposing them to the dangers of under-anticoagulation (i.e. thrombosis formation) or over-anticoagulation (i.e. bleeding). A new generation of OACs with improved pharmacology promises to revolutionize antithrombotic management. Rivaroxaban, apixaban (both oral direct Factor Xa inhibitors) and dabigatran (a direct thrombin inhibitor) all exhibit predictable anticoagulant responses and few drug-drug interactions and do not require routine coagulation monitoring. © 2011 The Author Fundamental and Clinical Pharmacology © 2011 Société Française de Pharmacologie et de Thérapeutique.

  7. Assessment of the effects of dalteparin on coagulation variables and determination of a treatment schedule for use in cats.

    PubMed

    Schönig, Jette C; Mischke, Reinhard H

    2016-07-01

    OBJECTIVE To determine a treatment protocol for SC administration of dalteparin to cats on the basis of currently available detailed pharmacokinetic data and to assess the effect of SC administration of dalteparin to cats on coagulation variables such as activated partial thromboplastin time (aPTT), thrombin time, and results for thromboelastometry, compared with effects on anti-activated coagulation factor X (anti-Xa) activity. ANIMALS 6 healthy domestic shorthair cats. PROCEDURES Cats received 14 injections of dalteparin (75 anti-Xa U/kg, SC) at 6-hour intervals. Blood samples were collected before and 2 hours after the first and second injections on days 1, 2, and 4. Anti-Xa activity was measured by use of a chromogenic substrate assay, aPTT and thrombin time were measured by use of an automated coagulometer, and viscoelastic measurements were obtained with thromboelastrometry. RESULTS 2 hours after the second injection, the target peak anti-Xa activity range of 0.5 to 1.0 U/mL was achieved in all cats, whereas median trough values remained below this range. Peak anti-Xa activity had only minimal effects on coagulation variables; the maximum median ratio for aPTT (in relationship to the value before the first dalteparin injection) was 1.23. CONCLUSIONS AND CLINICAL RELEVANCE Results of this study indicated that this treatment protocol resulted in reproducible anti-Xa activity in cats that was mostly within the targeted peak range of anti-Xa activity recommended for humans. Treatment in accordance with this protocol may not require routine coagulation monitoring of cats, but this must be confirmed in feline patients.

  8. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    PubMed

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  9. Coagulation indices in very preterm infants from cord blood and postnatal samples.

    PubMed

    Neary, E; McCallion, N; Kevane, B; Cotter, M; Egan, K; Regan, I; Kirkham, C; Mooney, C; Coulter-Smith, S; Ní Áinle, F

    2015-11-01

    Very premature infants are at high risk of bleeding complications; however, few data exist on ranges for standard coagulation tests. The primary objective of this study was to measure standard plasma coagulation tests and thrombin generation in very premature infants compared with term infants. The secondary objective was to evaluate whether an association existed between coagulation indices and intraventricular hemorrhage (IVH). Cord and peripheral blood of neonates < 30 weeks gestational age (GA) was drawn at birth, on days 1 and 3 and fortnightly until 30 weeks corrected gestational age. Prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen and coagulation factor levels were measured and tissue factor-stimulated thrombin generation was characterized. Control plasma was obtained from cord blood of term neonates. One hundred and sixteen infants were recruited. Median (range) GA was 27.7 (23.7-29.9) weeks and mean (SD) birth weight was 1020 (255) g. Median (5th-95th percentile) day 1 PT, APTT and fibrinogen were 17.5 (12.7-26.6) s, 78.7 (48.7-134.3) s and 1.4 (0.72-3.8) g L(-1) , respectively. No difference in endogenous thrombin potential between preterm and term plasma was observed, where samples were available. Levels of coagulation factors II, VII, IX and X, protein C, protein S and antithrombin were reduced in preterm compared with term plasma. Day 1 APTT and PT were not associated with IVH. In the largest cross-sectional study to date of very preterm infants, typical ranges for standard coagulation tests were determined. Despite long clotting times, thrombin generation was observed to be similar in very preterm and term infants. © 2015 International Society on Thrombosis and Haemostasis.

  10. Coagulation changes during lower body negative pressure and blood loss in humans.

    PubMed

    van Helmond, Noud; Johnson, Blair D; Curry, Timothy B; Cap, Andrew P; Convertino, Victor A; Joyner, Michael J

    2015-11-01

    We tested the hypothesis that markers of coagulation activation are greater during lower body negative pressure (LBNP) than those obtained during blood loss (BL). We assessed coagulation using both standard clinical tests and thrombelastography (TEG) in 12 men who performed a LBNP and BL protocol in a randomized order. LBNP consisted of 5-min stages at 0, -15, -30, and -45 mmHg of suction. BL included 5 min at baseline and following three stages of 333 ml of blood removal (up to 1,000 ml total). Arterial blood draws were performed at baseline and after the last stage of each protocol. We found that LBNP to -45 mmHg is a greater central hypovolemic stimulus versus BL; therefore, the coagulation markers were plotted against central venous pressure (CVP) to obtain stimulus-response relationships using the linear regression line slopes for both protocols. Paired t-tests were used to determine whether the slopes of these regression lines fell on similar trajectories for each protocol. Mean regression line slopes for coagulation markers versus CVP fell on similar trajectories during both protocols, except for TEG α° angle (-0.42 ± 0.96 during LBNP vs. -2.41 ± 1.13°/mmHg during BL; P < 0.05). During both LBNP and BL, coagulation was accelerated as evidenced by shortened R-times (LBNP, 9.9 ± 2.4 to 6.2 ± 1.1; BL, 8.7 ± 1.3 to 6.4 ± 0.4 min; both P < 0.05). Our results indicate that LBNP models the general changes in coagulation markers observed during BL. Copyright © 2015 the American Physiological Society.

  11. Improvement of coagulation laboratory practice in Thailand: the first-year experience of the national external quality assessment scheme for blood coagulation.

    PubMed

    Tientadakul, Panutsaya; Opartkiattikul, Nisarat; Wongtiraporn, Wanida

    2009-01-01

    In Thailand until 2005 there had been no external quality assessment scheme at the national level for blood coagulation tests. Only a few laboratories had an external quality assessment for these tests. In the year 2005, the Thailand National External Quality Assessment Scheme for Blood Coagulation was founded. To describe the establishment of the Thailand National External Quality Assessment Scheme for Blood Coagulation (including problems encountered and solutions), its progression and expansion, and the improvement of coagulation laboratory practice in Thailand during 2 trial surveys and 4 formal surveys conducted in the first 1 1/2 years. Between 2005 and 2006, the external quality assessment samples for prothrombin time/international normalized ratio and activated partial thromboplastin time were distributed to the participants as well as the instructions and suggestions for the improvement of laboratory practice. From the data collected, the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time was calculated for each survey. The number of participants increased during the first 1 1/2 years that the surveys were conducted, from 109 to 127. Survey data demonstrate an improvement in response rate and an increase in the number of laboratories that determine their own reference ranges and repeat this for every change of reagent lot, using the appropriate anticoagulant. The increased precision of tests is indicated by the decrease of the all-method coefficient of variation of the international normalized ratio and activated partial thromboplastin time. Examples of individual laboratory improvement through feedback are also described. The improvement of coagulation laboratory practice both through the instructions provided and liaison with participants was observed during the course of this scheme.

  12. [Removal of DON in micro-polluted raw water by coagulation and adsorption using activated carbon].

    PubMed

    Liu, Bing; Yu, Guo-Zhong; Gu, Li; Zhao, Cheng-Mei; Li, Qing-Fei; Zhai, Hui-Min

    2013-04-01

    Dissolved organic nitrogen as a precursor of new type nitrogenous disinfection by-products in drinking water attracted gradually the attention of scholars all over the world. In order to explore the mechanism of DON removal in micro-polluted raw water by coagulation and adsorption, water quality parameters, such as DON, DOC, NH4(+) -N, UV254, pH and dissolved oxygen, were determined in raw water and the molecular weight distribution of the DON and DOC was investigated. The variations in DON, DOC and UV254 in the coagulation and adsorption tests were investigated, and the changes of DON in raw water were characterized using three-dimensional fluorescence spectroscopy. The results showed that DON, DOC and UV254 were 1.28 mg x L(-1), 8.56 mg x L(-1), 0.16 cm(-1), and DOC/DON and SUVA were 6.69 mg x mg(-1), 1.87 m(-1) x (mg x L(-1))(-1) in raw water, respectively. The molecular weight distribution of the DON in raw water showed a bimodal distribution. The small molecular weight (< 6 000) fractions accounted for a high proportion of 68% and the large (> 20 000) fractions accounted for about 22%. The removal of DON, DOC and UV254 was about 20%, 26% and 70%, respectively, in the coagulation test and the dosage of coagulant was 10 mg x L(-1). The removal of DON, DOC and UV254 was about 60%, 35% and 100%, respectively, in the adsorption test and the dosage of activated carbon was 1.0 g. In the combination of coagulation and adsorption, the removal of DON and DOC reached approximately 82% and 64%, respectively. 3DEEM revealed that the variation of DON in the coagulation and adsorption tests depended intimately on tryptophan protein-like substances, aromatic protein-like substances and fulvic acid-like substances.

  13. Multi-organ dysfunction due to bath salts: are we aware of this entity?

    PubMed

    Valsalan, Rohith; Varghese, Benoj; Soman, Diya; Buckmaster, Jonathan; Yew, Steven; Cooper, David

    2017-01-01

    Methylenedioxypyrovalerone (MDPV) is a synthetic, cathinone-derivative, central nervous system stimulant taken to produce a cocaine- or methamphetamine-like high. Physical manifestations include tachycardia, hypertension, arrhythmias, hyperthermia, sweating, rhabdomyolysis, hyperkalaemia, disseminated intravascular coagulation, oliguria and seizures. We report a patient who presented with severe metabolic acidosis, multi-organ dysfunction, rhabdomyolysis, hyperkalaemia and seizures. This case highlights that even though a urine drug screen for routine psychostimulant drugs is negative, clinicians need to be vigilant about the adverse effects of MDPV as a possible cause of multi-organ dysfunction. Substances such as this can only be detected by special tests, such as gas/liquid chromatography mass spectrometry. This is the first reported case of MDPV toxicity successfully treated in Australia to the best of our knowledge. © 2017 Royal Australasian College of Physicians.

  14. Diagnostic testing for coagulopathies in patients with ischemic stroke.

    PubMed

    Bushnell, C D; Goldstein, L B

    2000-12-01

    Hypercoagulable states are a recognized, albeit uncommon, etiology of ischemic stroke. It is unclear how often the results of specialized coagulation tests affect management. Using data compiled from a systematic review of available studies, we employed quantitative methodology to assess the diagnostic yield of coagulation tests for identification of coagulopathies in ischemic stroke patients. We performed a MEDLINE search to identify controlled studies published during 1966-1999 that reported the prevalence of deficiencies of protein C, protein S, antithrombin III, plasminogen, activated protein C resistance (APCR)/factor V Leiden mutation (FVL), anticardiolipin antibodies (ACL), or lupus anticoagulant (LA) in patients with ischemic stroke. The cumulative prevalence rates (pretest probabilities) and positive likelihood ratios for all studies and for those including only patients aged

  15. Performance of ultrafiltration membrane process combined with coagulation/sedimentation.

    PubMed

    Jang, N Y; Watanabe, Y; Minegishi, S

    2005-01-01

    Effects of coagulation/sedimentation as a pre-treatment on the dead-end ultrafiltration (UF) membrane process were studied in terms of membrane fouling and removal efficiency of natural dissolved organic matter, using Chitose River water. Two types of experiment were carried out. One was a bench scale membrane filtration with jar-test and the other was membrane filtration pilot plant combined with the Jet Mixed Separator (JMS) as a pre-coagulation/sedimentation unit. In the bench scale experiment, the effects of coagulant dosage, pH and membrane operating pressure on the membrane fouling and removal efficiency of natural dissolved organic matter were investigated. In the pilot plant experiment, we also investigated the effect of pre-coagulation/sedimentation on the membrane fouling and the removal efficiency of natural dissolved organic matter. Coagulation/sedimentation prior to membrane filtration process controlled the membrane fouling and increased the removal efficiency of natural dissolved organic matter.

  16. Performance of alum and assorted coagulants in turbidity removal of muddy water

    NASA Astrophysics Data System (ADS)

    Malik, Qasim H.

    2018-03-01

    Coagulation is a primary and cost effective process in water treatment plants. Under optimum conditions, not only it effectively removes turbidity but also results in reduced sludge volume and subsequently minimizes sludge management costs. Highly turbid water from streams, canals, rivers and rain run offs was run through jar test for turbidity removal. The brown water with 250NTU turbidity when coagulated with alum and assorted coagulants proved that maximum turbidity removal was witnessed using alum dose of 0.25 g/l at ph 6 with a sedimentation time of 30 min.

  17. Coagulation Management in Jersey Calves: An ex vivo Study.

    PubMed

    Gröning, Sabine; Maas, Judith; van Geul, Svenja; Rossaint, Rolf; Steinseifer, Ulrich; Grottke, Oliver

    2017-01-01

    Jersey calves are frequently used as an experimental animal model for in vivo testing of cardiac assist devices or orthopedic implants. In this ex vivo study, we analyzed the coagulation system of the Jersey calves and the potential of human-based coagulation management to circumvent perioperative bleeding complications during surgery. Experimental Procedure: Blood from 7 Jersey calves was subjected to standard laboratory tests and thromboelastometry analysis. An ex vivo model of dilutional coagulopathy was used to study the effects of fibrinogen or prothrombin complex concentrate supplementation. Fibrinolysis was induced with tissue plasminogen activator to identify potential therapeutic strategies involving tranexamic acid or aprotinin. Furthermore, anticoagulation strategies were evaluated by incubating the blood samples with dabigatran or rivaroxaban. Baseline values for thromboelastometry and standard laboratory parameters, including prothrombin time, activated partial thromboplastin time, fibrinogen, antithrombin III, and D-dimers, were established. Fifty percent diluted blood showed a statistically significant impairment of hemostasis. The parameters significantly improved after the administration of fibrinogen or prothrombin complex concentrate. Tranexamic acid and aprotinin ameliorated tissue plasminogen activator-induced fibrinolysis. Both dabigatran and rivaroxaban significantly prolonged the coagulation parameters. In this ex vivo study, coagulation factors, factor concentrate, antifibrinolytic reagents, and anticoagulants regularly used in the clinic positively impacted coagulation parameters in Jersey calf blood. © 2017 S. Karger AG, Basel.

  18. Treatment of melanoidin wastewater by anaerobic digestion and coagulation.

    PubMed

    Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe

    2015-01-01

    Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.

  19. Removal of boron (B) from waste liquors.

    PubMed

    Jiang, J Q; Xu, Y; Simon, J; Quill, K; Shettle, K

    2006-01-01

    This paper explores the use of electrocoagulation to remove boron from waste effluent in comparison with alum coagulation. In treating model test wastes, greater boron removals were achieved with electrocoagulation at low doses than conventional alum coagulation when reaction was undertaken for the same conditions (pH 8.5, and initial boron concentration was 500 mg/L). Al electrocoagulation can achieve good boron removal performance (68.3%) at a dose of 2.1 (as molar ratio of Al:B, and for current density of 62.1 A/m2), while alum coagulation can only achieve the maximum boron removal of 56% at a dose of 2.4. Also, Al electrocoagulation can remove 15-20% more boron than alum coagulation for the same dose compared in the treatment of both model test wastes and industry effluent. The estimation of running costs shows that to achieve 75% boron removal from industry waste effluent, i.e. removing 150 g of boron from 1 m3 of effluent, electrocoagulation was 6.2 times cheaper than alum coagulation. The economic advantage of electrocoagulation in the treatment of boron-containing waste effluent is thus significant.

  20. Promyelocytic extracellular chromatin exacerbates coagulation and fibrinolysis in acute promyelocytic leukemia

    PubMed Central

    Cao, Muhua; Li, Tao; He, Zhangxiu; Wang, Lixiu; Yang, Xiaoyan; Kou, Yan; Zou, Lili; Dong, Xue; Novakovic, Valerie A.; Bi, Yayan; Kou, Junjie; Yu, Bo; Fang, Shaohong; Wang, Jinghua; Zhou, Jin

    2017-01-01

    Despite routine treatment of unselected acute promyelocytic leukemia (APL) with all-trans-retinoic acid (ATRA), early death because of hemorrhage remains unacceptably common, and the mechanism underlying this complication remains elusive. We have recently demonstrated that APL cells undergo a novel cell death program, termed ETosis, which involves release of extracellular chromatin. However, the role of promyelocytic extracellular chromatin in APL-associated coagulation remains unclear. Our objectives were to identify the novel role of ATRA-promoted extracellular chromatin in inducing a hypercoagulable and hyperfibrinolytic state in APL and to evaluate its interaction with fibrin and endothelial cells (ECs). Results from a series of coagulation assays have shown that promyelocytic extracellular chromatin increases thrombin and plasmin generation, causes a shortening of plasma clotting time of APL cells, and increases fibrin formation. DNase I but not anti-tissue factor antibody could inhibit these effects. Immunofluorescence staining showed that promyelocytic extracellular chromatin and phosphatidylserine on APL cells provide platforms for fibrin deposition and render clots more resistant to fibrinolysis. Additionally, coincubation assays revealed that promyelocytic extracellular chromatin is cytotoxic to ECs, converting them to a procoagulant phenotype. This cytotoxity was blocked by DNase I by 20% or activated protein C by 31%. Our current results thus delineate the pathogenic role of promyelocytic extracellular chromatin in APL coagulopathy. Furthermore, the remaining coagulation disturbance in high-risk APL patients after ATRA administration may be treatable by intrinsic pathway inhibition via accelerating extracellular chromatin degradation. PMID:28053193

  1. Effects of oversulfated and fucosylated chondroitin sulfates on coagulation. Challenges for the study of anticoagulant polysaccharides.

    PubMed

    Fonseca, Roberto J C; Oliveira, Stephan-Nicollas M C G; Pomin, Vitor H; Mecawi, André S; Araujo, Iracema G; Mourão, Paulo A S

    2010-05-01

    We report the effects of a chemically oversulfated chondroitin sulfate and a naturally fucosylated chondroitin sulfate on the coagulation system. The former has been recently identified as a contaminant of heparin preparations and the latter has been proposed as an alternative anticoagulant. The mechanism of action of these polymers on coagulation is complex and target different components of the coagulation system. They have serpin-independent anticoagulant activity, which preponderates in plasma. They also have serpin-dependent anticoagulant activity but differ significantly in the target coagulation protease and preferential serpin. Their anticoagulant effects differ even more markedly when tested as inhibitors of coagulation proteases using plasma as a source of serpins. It is possible that the difference is due to the high availability of fucosylated chondroitin sulfate whereas oversulfated chondroitin sulfate has strong unspecific binding to plasma protein and low availability for the binding to serpins. When tested using a venous thrombosis experimental model, oversulfated chondroitin sulfate is less potent as an antithrombotic agent than fucosylated chondroitin sulfate. These highly sulfated chondroitin sulfates activate factor XII in in vitro assays, based on kallikrein release. However, only fucosylated chondroitin sulfate induces hypotension when intravenously injected into rats. In conclusion, the complexity of the regulatory mechanisms involved in the action of highly sulfated polysaccharides in coagulation requires their analysis by a combination of in vitro and in vivo assays. Our results are relevant due to the urgent need for new anticoagulant drugs or alternative sources of heparin.

  2. Performance Evaluation of Five Different Disseminated Intravascular Coagulation (DIC) Diagnostic Criteria for Predicting Mortality in Patients with Complicated Sepsis.

    PubMed

    Ha, Sang Ook; Park, Sang Hyuk; Hong, Sang Bum; Jang, Seongsoo

    2016-11-01

    Disseminated intravascular coagulation (DIC) is a major complication in sepsis patients. We compared the performance of five DIC diagnostic criteria, focusing on the prediction of mortality. One hundred patients with severe sepsis or septic shock admitted to intensive care unit (ICU) were enrolled. Routine DIC laboratory tests were performed over the first 4 days after admission. The overall ICU and 28-day mortality in DIC patients diagnosed from five criteria (International Society on Thrombosis and Haemostasis [ISTH], the Japanese Association for Acute Medicine [JAAM], the revised JAAM [R-JAAM], the Japanese Ministry of Health and Welfare [JMHW] and the Korean Society on Thrombosis and Hemostasis [KSTH]) were compared. Both KSTH and JMHW criteria showed superior performance than ISTH, JAAM and R-JAAM criteria in the prediction of overall ICU mortality in DIC patients (odds ratio 3.828 and 5.181, P = 0.018 and 0.006, 95% confidence interval 1.256-11.667 and 1.622-16.554, respectively) when applied at day 1 after admission, and survival analysis demonstrated significant prognostic impact of KSTH and JMHW criteria on the prediction of 28-day mortality (P = 0.007 and 0.049, respectively) when applied at day 1 after admission. In conclusion, both KSTH and JMHW criteria would be more useful than other three criteria in predicting prognosis in DIC patients with severe sepsis or septic shock.

  3. Thromboelastography Values in Hispaniolan Amazon Parrots ( Amazona ventralis ): A Pilot Study.

    PubMed

    Keller, Krista A; Sanchez-Migallon Guzman, David; Acierno, Mark J; Beaufrère, Hugues; Sinclair, Kristin M; Owens, Sean D; Paul-Murphy, Joanne; Tully, Thomas N

    2015-09-01

    Thromboelastography (TEG) provides a global assessment of coagulation, including the rate of clot initiation, clot kinetics, achievement of maximum clot strength, and fibrinolysis. Thromboelastography (TEG) is used with increasing frequency in the field of veterinary medicine, although its usefulness in avian species has not been adequately explored. The purpose of this preliminary study was to assess the applicability of TEG in psittacine birds. Kaolin-activated TEG was used to analyze citrated whole blood collected routinely from 8 healthy adult Hispaniolan Amazon parrots ( Amazona ventralis ). The minimum and maximum TEG values obtained included time to clot initiation (2.6-15 minutes), clot formation time (4.3-20.8 minutes), α angle (12.7°-47.9°), maximum amplitude of clot strength (26.3-46.2 mm), and percentage of lysis 30 minutes after achievement of maximum amplitude (0%-5.3%). The TEG values demonstrated comparative hypocoagulability relative to published values in canine and feline species. Differences may be explained by either the in vitro temperature at which TEG is standardly performed or the method of activation used in this study. Although TEG may have significant advantages over traditional coagulation tests, including lack of need for species-specific reagents, further evaluation is required in a variety of avian species and while exploring various TEG methodologies before this technology can be recommended for use in clinical cases.

  4. Influence of NaCl Concentrations on Coagulation, Temperature, and Electrical Conductivity Using a Perfusion Radiofrequency Ablation System: An Ex Vivo Experimental Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aube, Christophe, E-mail: ChAube@chu-angers.fr; Schmidt, Diethard; Brieger, Jens

    2007-02-15

    Purpose. To determine, by means of an ex vivo study, the effect of different NaCl concentrations on the extent of coagulation obtained during radiofrequency (RF) ablation performed using a digitally controlled perfusion device. Method. Twenty-eight RF ablations were performed with 40 W for 10 min using continuous NaCl infusion in fresh excised bovine liver. For perfusion, NaCl concentrations ranging from 0 (demineralized water) to 25% were used. Temperature, the amount of energy, and the dimensions of thermal-induced white coagulation were assessed for each ablation. These parameters were compared using the nonparametric Mann-Whitney test. Correlations were calculated according to the Spearmanmore » test. Results. RF ablation performed with 0.9% to 25% concentrations of NaCl produced a mean volume of coagulation of 30.7 {+-} 3.8 cm{sup 3}, with a mean short-axis diameter of 3.6 {+-} 0.2 cm. The mean amount of energy was 21,895 {+-} 1,674 W and the mean temperature was 85.4 {+-} 12.8 deg. C. Volume of coagulation, short-axis diameter, and amount of energy did not differ significantly among NaCl concentrations (p > 0.5). A correlation was found between the NaCl concentration and the short-axis diameter of coagulation (r = 0.64) and between the NaCl concentration and the mean temperature (r = 0.67), but not between the NaCl concentration and volume of coagulation. Conclusion. In an ex vivo model, continuous perfusion with high NaCl concentrations does not significantly improve the volume of thermal-induced coagulation. This may be because the use of a low-power generator cannot sufficiently exploit the potential advantage of better tissue conductivity provided by NaCl perfusion.« less

  5. Simultaneous removal of ammonia and N-nitrosamine precursors from high ammonia water by zeolite and powdered activated carbon.

    PubMed

    Xue, Runmiao; Donovan, Ariel; Zhang, Haiting; Ma, Yinfa; Adams, Craig; Yang, John; Hua, Bin; Inniss, Enos; Eichholz, Todd; Shi, Honglan

    2018-02-01

    When adding sufficient chlorine to achieve breakpoint chlorination to source water containing high concentration of ammonia during drinking water treatment, high concentrations of disinfection by-products (DBPs) may form. If N-nitrosamine precursors are present, highly toxic N-nitrosamines, primarily N-nitrosodimethylamine (NDMA), may also form. Removing their precursors before disinfection should be a more effective way to minimize these DBPs formation. In this study, zeolites and activated carbon were examined for ammonia and N-nitrosamine precursor removal when incorporated into drinking water treatment processes. The test results indicate that Mordenite zeolite can remove ammonia and five of seven N-nitrosamine precursors efficiently by single step adsorption test. The practical applicability was evaluated by simulation of typical drinking water treatment processes using six-gang stirring system. The Mordenite zeolite was applied at the steps of lime softening, alum coagulation, and alum coagulation with powdered activated carbon (PAC) sorption. While the lime softening process resulted in poor zeolite performance, alum coagulation did not impact ammonia and N-nitrosamine precursor removal. During alum coagulation, more than 67% ammonia and 70%-100% N-nitrosamine precursors were removed by Mordenite zeolite (except 3-(dimethylaminomethyl)indole (DMAI) and 4-dimethylaminoantipyrine (DMAP)). PAC effectively removed DMAI and DMAP when added during alum coagulation. A combination of the zeolite and PAC selected efficiently removed ammonia and all tested seven N-nitrosamine precursors (dimethylamine (DMA), ethylmethylamine (EMA), diethylamine (DEA), dipropylamine (DPA), trimethylamine (TMA), DMAP, and DMAI) during the alum coagulation process. Copyright © 2017. Published by Elsevier B.V.

  6. Equiosmolar Solutions of Hypertonic Saline and Mannitol Do Not Impair Blood Coagulation During Elective Intracranial Surgery.

    PubMed

    Hernández-Palazón, Joaquín; Fuentes-García, Diego; Doménech-Asensi, Paloma; Piqueras-Pérez, Claudio; Falcón-Araña, Luis; Burguillos-López, Sebastián

    2017-01-01

    The authors investigated the effect of equiosmolar, equivolemic solutions of 3% hypertonic saline (HS) and 20% mannitol on blood coagulation assessed by rotational thromboelastometry (ROTEM) and standard coagulation tests during elective craniotomy. In a prospective, randomized, double-blind trial, 40 patients undergoing elective craniotomy were randomized to receive 5 mL/kg of either 20% mannitol or 3% HS for intraoperative brain relaxation. Fibrinogen, activated partial thromboplastin time, prothrombin time, hemoglobin, hematocrit, and platelet count were simultaneously measured intraoperatively with ROTEM for EXTEM, INTEM, and FIBTEM analysis. ROTEM parameters were: clotting time (CT), clot formation time (CFT), maximum clot firmness (MCF), and α-angle. No significant differences between groups were found in ROTEM variables CT, CFT, MCF, α-angle (EXTEM and INTEM), and MCF (FIBTEM) nor standard coagulation tests. ROTEM parameters did not show changes after administration of hyperosmolar solutions relating to basal values, except for an increase of CFT EXTEM (118±28 vs. 128±26 s) and decrease of CT INTEM (160±18 vs. 148±15 s) with values within normal range. Significant decreases from baseline levels were observed for hematocrit (-7%), platelet count (-10%), and fibrinogen (-13%) after HS infusion, and hematocrit (-9%), platelet count (-13%), and fibrinogen (-9%) after mannitol infusion, but remaining normal. The use of 5 mL/kg of equiosmolar solutions of 3% HS and 20% mannitol applied to reach a brain relaxation during elective craniotomy does not induce coagulation impairment as evidenced by ROTEM and standard coagulation tests.

  7. Removal of Arsenic from Drinking Water by Adsorption and Coagulation

    NASA Astrophysics Data System (ADS)

    Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.

    2013-12-01

    Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment, Arsenic, Adsorption, Coagulation, Drinking Water, Bangladesh

  8. Coagulation cascade and complement system in systemic lupus erythematosus

    PubMed Central

    Liang, Yan; Xie, Shang-Bo; Wu, Chang-Hao; Hu, Yuan; Zhang, Qin; Li, Si; Fan, Yin-Guang; Leng, Rui-Xue; Pan, Hai-Feng; Xiong, Hua-Bao; Ye, Dong-Qing

    2018-01-01

    This study was conducted to (1) characterize coagulation cascade and complement system in systemic lupus erythematosus (SLE); (2) evaluate the associations between coagulation cascade, complement system, inflammatory response and SLE disease severity; (3) test the diagnostic value of a combination of D-dimer and C4 for lupus activity. Transcriptomics, proteomics and metabolomics were performed in 24 SLE patients and 24 healthy controls. The levels of ten coagulations, seven complements and three cytokines were measured in 112 SLE patients. Clinical data were collected from 2025 SLE patients. The analysis of multi-omics data revealed the common links for the components of coagulation cascade and complement system. The results of ELISA showed coagulation cascade and complement system had an interaction effect on SLE disease severity, this effect was pronounced among patients with excess inflammation. The analysis of clinical data revealed a combination of D-dimer and C4 provided good diagnostic performance for lupus activity. This study suggested that coagulation cascade and complement system become ‘partners in crime’, contributing to SLE disease severity and identified the diagnostic value of D-dimer combined with C4for lupus activity. PMID:29599912

  9. CRYPTOSPORIDIUM INACTIVATION AND REMOVAL RESEARCH

    EPA Science Inventory

    Bench- and pilot-scale tests were performed to assess the ability of conventional treatment, ozonation and chlorine dioxide to remove and inactivate Cryptosporidium oocysts. The impacts of coagulant type, coagulant dose, raw water quality, filter loading rates and filter media w...

  10. Coagulation parameters in senior athletes practicing endurance sporting activity.

    PubMed

    Cerneca, E; Simeone, R; Bruno, G; Gombacci, A

    2005-12-01

    Physical activity is practiced more and more by middle-aged people. We studied the behavior of the coagulation system before and after near-maximum, specific and standardized exercise tests in 2 groups of senior athletes. The subjects of the study were 2 groups of athletes over 40 years of age (ranging 41 to 60 years): 10 rowers and 10 marathon runners. The data were compared with 10 controls (ranging in age from 40 to 71 years) tested on the cycle ergometer. The first group (rowers) was tested on a rowing machine; the second group (marathon runners) performed a maximal exercise on the treadmill. All subjects were tested to a maximal level of cardiovascular and muscular exertion and cardiac and respiratory parameters were monitored. The following coagulation tests were performed before and after maximal exercise: prothrombin time (PT), partial activated thromboplastin time (PTT), fibrinogen (FBG), antithrombin III (ATIII), protein C (PC), protein S (PS), prothrombin fragment 1+2 (F1+2), tissue activator of plasminogen (t-PA) and its inhibitor (PAI). All subjects performed a complete maximal specific test. The results showed all individuals produced a significant increase of FBG, PT and PTT activities and a lowering trend for PC and PS inhibitors after maximal exercise testing. ATIII levels increased significantly in trained subjects. After the test, data regarding fibrinolysis showed higher t-PA levels in athletes as compared with controls. PAI levels indicated a more marked decrease in athletes. The F1+2 showed a moderate but significant increase in the control group. Coagulative tests showed an increase in procoagulant and fibrinolysis parameters in all the groups but the increased fibrinolytic activity in trained athletes indicates a protective factor and greater vascular efficiency. The results demonstrate that sporting activity practiced by middle-aged people accelerates fibrinolytic activity in conditioned subjects. In conclusion, physical activity benefits the coagulation system particularly as regards fibrinolysis.

  11. [Explore method about post-marketing safety re-evaluation of Chinese patent medicines based on HIS database in real world].

    PubMed

    Yang, Wei; Xie, Yanming; Zhuang, Yan

    2011-10-01

    There are many kinds of Chinese traditional patent medicine used in clinical practice and many adverse events have been reported by clinical professionals. Chinese patent medicine's safety problems are the most concerned by patients and physicians. At present, many researchers have studied re-evaluation methods about post marketing Chinese medicine safety inside and outside China. However, it is rare that using data from hospital information system (HIS) to re-evaluating post marketing Chinese traditional patent medicine safety problems. HIS database in real world is a good resource with rich information to research medicine safety. This study planed to analyze HIS data selected from ten top general hospitals in Beijing, formed a large HIS database in real world with a capacity of 1 000 000 cases in total after a series of data cleaning and integrating procedures. This study could be a new project that using information to evaluate traditional Chinese medicine safety based on HIS database. A clear protocol has been completed as for the first step for the whole study. The protocol is as follows. First of all, separate each of the Chinese traditional patent medicines existing in the total HIS database as a single database. Secondly, select some related laboratory tests indexes as the safety evaluating outcomes, such as routine blood, routine urine, feces routine, conventional coagulation, liver function, kidney function and other tests. Thirdly, use the data mining method to analyze those selected safety outcomes which had abnormal change before and after using Chinese patent medicines. Finally, judge the relationship between those abnormal changing and Chinese patent medicine. We hope this method could imply useful information to Chinese medicine researchers interested in safety evaluation of traditional Chinese medicine.

  12. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  13. ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation

    PubMed Central

    Chen, Da; Zhang, Zhen; Ma, Jilong; Wang, Wei

    2017-01-01

    Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately −217 kHz/cP between the liquid viscosity and the frequency of the resonator. The downshift of the resonant frequency and the viscosity change during the blood coagulation were correlated to monitor the coagulation process. The sigmoidal trend was observed in the frequency response for the blood samples activated by thromboplastin and calcium ions. The coagulation kinetics involving sequential phases of steady reaction, growth and saturation were revealed through the time-dependent frequency profiles. The enzymatic cascade time, the coagulation rate, the coagulation time and the clot degree were provided by fitting the time-frequency curves. The prothrombin times were compared with the results measured by a standard coagulometer and show a good correlation. Thanks to the excellent potential of integration, miniaturization and the availability of direct digital signals, the film bulk acoustic resonator has promising application for both clinical and personal use coagulation testing technologies. PMID:28467374

  14. Improving the Efficiency of Natural Raw Water Pretreatment at Thermal Power Stations

    NASA Astrophysics Data System (ADS)

    Dremicheva, E. S.

    2018-02-01

    In the treatment of make-up water for thermal power stations (TPS) and heat networks, raw water from surface water bodies is used. It contains organic and mineral pollutants in the form of particulates or colloids. Coagulation and flocculation are reagent methods for removing these pollutants from water. Chemicals are used to assist in the formation of large structured flakes that are removed easily from water. The Kuibyshev water reservoir was selected as the object of investigation. Basic physical and chemical properties of the raw water are presented. The application of various coagulating agents, their mixtures in different proportions, and flocculating agents for clarifying the Volga water was examined. The required dose of a coagulant or flocculant was determined based on test coagulation of the treated water. Aluminum sulfate and iron (III) chloride were used a coagulant, and Praestol 2500 (nonionic) as a flocculant. A method of enhancement of coagulation and flocculation by injecting air into the treated water is examined. The results of experimental investigation of the effect of water treatment method on water quality indices, such as alkalinity, pH, iron content, suspended material content, and permanganate value, are presented. It is demonstrated that joint use of ironand aluminum containing coagulation agents brings the coagulation conditions closer to the optimum ones. Aeration does not affect the coagulation process. The methods for supplying air to a clarifier are proposed for practical implementation.

  15. Effectiveness and mechanism of potassium ferrate(VI) preoxidation for algae removal by coagulation.

    PubMed

    Ma, Jun; Liu, Wei

    2002-02-01

    Jar tests were conducted to evaluate the effectiveness of potassium ferrate preoxidation on algae removal by coagulation. Laboratory studies demonstrated that pretreatment with potassium ferrate obviously enhanced the algae removal by coagulation with alum [Al2(SO4)3 . 18H2O]. Algae removal efficiency increased remarkably when the water was pretreated with ferrate. A very short time of preoxidation was enough to achieve substantial algae removal efficiency, and the effectiveness was further increased at a prolonged pretreatment time. Pretreatment with ferrate resulted in a reduction of alum dosage required to cause an efficient coagulation for algae removal. The obvious impact of cell architecture by potassium ferrate was found through scanning electron microscopy. Upon oxidation with ferrate. the cells were inactivated and some intracellular and extracelluar components were released into the water, which may be helpful to the coagulation by their bridging effect. Efficient removal of algae by potassium ferrate preoxidation is believed to be a consequence of several process mechanisms. Ferrate preoxidation inactivated algae, induced the formation of coagulant aid, which are the cellular components secreted by algal cells. The coagulation was also improved by increasing particle concentration in water, because of the formation of the intermediate forms of precipitant iron species during preoxidation. In addition, it was also observed that ferrate preoxidation caused algae agglomerate formation before the addition of coagulant, the subsequent application of alum resulted in further coagulation.

  16. Haemostatic monitoring during postpartum haemorrhage and implications for management

    PubMed Central

    Solomon, C.; Collis, R. E.; Collins, P. W.

    2012-01-01

    Summary Postpartum haemorrhage (PPH) is a major risk factor for maternal morbidity and mortality. PPH has numerous causative factors, which makes its occurrence and severity difficult to predict. Underlying haemostatic imbalances such as consumptive and dilutional coagulopathies may develop during PPH, and can exacerbate bleeding and lead to progression to severe PPH. Monitoring coagulation status in patients with PPH may be crucial for effective haemostatic management, goal-directed therapy, and improved outcomes. However, current PPH management guidelines do not account for the altered baseline coagulation status observed in pregnant patients, and the appropriate transfusion triggers to use in PPH are unknown, due to a lack of high-quality studies specific to this area. In this review, we consider the evidence for the use of standard laboratory-based coagulation tests and point-of-care viscoelastic coagulation monitoring in PPH. Many laboratory-based tests are unsuitable for emergency use due to their long turnaround times, so have limited value for the management of PPH. Emerging evidence suggests that viscoelastic monitoring, using thrombelastography- or thromboelastometry-based tests, may be useful for rapid assessment and for guiding haemostatic therapy during PPH. However, further studies are needed to define the ranges of reference values that should be considered ‘normal’ in this setting. Improving awareness of the correct application and interpretation of viscoelastic coagulation monitoring techniques may be critical in realizing their emergency diagnostic potential. PMID:23075633

  17. Impact of organic polyelectrolytes on coagulation of source-separated black water.

    PubMed

    Kozminykh, Pavlo; Heistad, Arve; Ratnaweera, Harsha C; Todt, Daniel

    2016-01-01

    Household wastewater is originated from common people's activities and has a potential harmful impact on the environment if discharged directly without proper treatment. Toilet wastewater or black water (BW) contains urine, faeces, toilet paper and flushing water and it contains the majority of pollutants obtained from a single household. In this study, the focus was on BW treatment using chemical methods. The main goal of current research was to define the possibility and applicability of conventional coagulants and flocculants in direct chemical treatment of vacuum-collected BW to remove particles, organic matter and phosphorous. After the definition of dosing ranges, based on the equivalent doses in conventional municipal and industrial wastewater treatment data, aluminium and iron coagulants, organic polyelectrolytes (polymers with anionic, neutral and cationic charge with different molecular weights) and their various combinations were tested using the well-known jar-test laboratory method to study aggregation and solid-liquid separation processes in raw BW. The most important process parameter during the coagulation was pH level, dependent on the type and doses of metal salts. Some side processes were found to occur while using iron-based coagulants. Dosing of either single coagulants or single polymers did not give satisfactory results, while a combination of aluminium salts and cationic polymers showed high removal rates in total suspended solids, total chemical oxygen demand and ortho-phosphates, reaching 97.8%, 92% and 98.6%, respectively, with the optimal doses of chemicals. Cationic polymers with the lowest molecular weight and highest charge density were the most efficient in combination with aluminium coagulants.

  18. Experimental investigation and modeling of dissolved organic carbon removal by coagulation from seawater.

    PubMed

    Jeong, Sanghyun; Sathasivan, Arumugam; Kastl, George; Shim, Wang Geun; Vigneswaran, Saravanamuthu

    2014-01-01

    Coagulation removes colloidal matters and dissolved organic carbon (DOC) which can cause irreversible membrane fouling. However, how DOC is removed by coagulant is not well-known. Jar test was used to study the removal of hydrophobic and hydrophilic DOC fractions at various doses (0.5-8.0 mg-Fe(+3) L(-1)) of ferric chloride (FeCl3) and pH (5.0-9.0). Natural organic matter (NOM) in seawater and treated seawater were fractionated by liquid chromatography-organic carbon detector (LC-OCD). Compared to surface water, the removal of DOC in seawater by coagulation was remarkably different. Majority of DOC could be easily removed with very low coagulant dose (<5.0 mg-Fe(+3) L(-1)) and the removal efficiency did not vary with pH, but the DOC composition in treated water had significantly changed. Hydrophobic fraction (HB) was better removed at high pH while hydrophilic fraction (HF) was better removed at low pH. A modified model of Kastl et al. (2004) which assumed that the removal occurred by adsorption of un-dissociated compounds onto ferric hydroxide was formulated and successfully validated against the jar test data. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.

    PubMed

    Onisor, I; Pecie, R; Chaskelis, I; Krejci, I

    2013-06-01

    To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.

  20. Hepatic dysfunction contributes to coagulation disturbances in patients undergoing whole body hyperthermia by use of extracorporeal circulation.

    PubMed

    Worel, Nina; Knöbl, Paul; Karanikas, Georgios; Fuchs, Eva-Maria; Bojic, Andja; Brodowicz, Thomas; Jilma, Petra; Zielinski, Christoph C; Köstler, Wolfgang J; Locker, Gottfried J

    2014-09-01

    This phase I study was performed to evaluate coagulation alterations during extracorporeal circulation (ECC) induced whole body hyperthermia (WBHT) in 12 patients with advanced soft tissue sarcomas. To distinguish between effects of normothermic ECC and ECC-WBHT, blood samples were drawn at different time points: at baseline, after 30 min on normothermic ECC, at the end of the heating period, and 24 h and 7 days thereafter. Standard coagulation tests, coagulation factors, thrombelastography,platelets and reticulated platelets, liver enzymes, and scintigraphic platelet imaging were performed. Normothermic ECC resulted in coagulation alterations most likely due to systemic anticoagulation. Induction of hyperthermia caused thrombocytopenia, increased fibrin degradation products,prolonged clotting times, alteration in coagulation factors, and increased liver enzymes. The majority of these effects was most pronounced 24 h after ECC-WBHT. In addition, late liver sequestration of platelets was demonstrated in scintigraphic imaging at that time point. Temporal correlation between hemostatic alterations and elevation in liver enzymes leads to the assumption that liver impairment might play a crucial role in coagulation disturbances observed during ECC-WBHT and thereafter, thus strongly supported by liver sequestration of platelets.Therefore a close monitoring of hepatic derived coagulation alterations in patients undergoing extracorporeal whole body hypothermia is warranted.

  1. REMOVAL OF BERYLLIUM FROM DRINKING WATER BY CHEMICAL COAGULATION AND LIME SOFTENING

    EPA Science Inventory

    The effectiveness of conventional drinking water treatment and lime softening was evaluated for beryllium removal from two drinking water sources. ar test studies were conducted to determine how common coagulants (aluminum sulfate and ferric chloride and lime softening performed ...

  2. Removal and Transformation of Estrogens During the Coagulation Process

    EPA Science Inventory

    Estrogenic compounds have been shown to be present in surface waters, leading to concerns over the possible presence of endocrine disrupting compounds in finished drinking waters. Bench-scale studies (jar tests) simulating coagulation were conducted to evaluate the ability of tw...

  3. Emergency Coagulation Assessment During Treatment With Direct Oral Anticoagulants: Limitations and Solutions.

    PubMed

    Ebner, Matthias; Birschmann, Ingvild; Peter, Andreas; Härtig, Florian; Spencer, Charlotte; Kuhn, Joachim; Blumenstock, Gunnar; Zuern, Christine S; Ziemann, Ulf; Poli, Sven

    2017-09-01

    In patients receiving direct oral anticoagulants (DOACs), emergency treatment like thrombolysis for acute ischemic stroke is complicated by insufficient availability of DOAC-specific coagulation tests. Conflicting recommendations have been published concerning the use of global coagulation assays for ruling out relevant DOAC-induced anticoagulation. Four hundred eighty-one samples from 96 DOAC-treated patients were tested using prothrombin time (PT), activated partial thromboplastin time (aPTT) and thrombin time (TT), DOAC-specific assays (anti-Xa activity, diluted TT), and liquid chromatography-tandem mass spectrometry. Sensitivity and specificity of test results to identify DOAC concentrations <30 ng/mL were calculated. Receiver operating characteristic analyses were used to define reagent-specific cutoff values. Normal PT and aPTT provide insufficient specificity to safely identify DOAC concentrations <30 ng/mL (rivaroxaban/PT: specificity, 77%/sensitivity, 94%; apixaban/PT: specificity, 13%/sensitivity, 94%, dabigatran/aPTT: specificity, 49%/sensitivity, 91%). Normal TT was 100% specific for dabigatran, but sensitivity was 26%. In contrast, reagent-specific PT and aPTT cutoffs provided >95% specificity and a specific TT cutoff enhanced sensitivity for dabigatran to 84%. For apixaban, no cutoffs could be established. Even if highly DOAC-reactive reagents are used, normal results of global coagulation tests are not suited to guide emergency treatment: whereas normal PT and aPTT lack specificity to rule out DOAC-induced anticoagulation, the low sensitivity of normal TT excludes the majority of eligible patients from treatment. However, reagent-specific cutoffs for global coagulation tests ensure high specificity and optimize sensitivity for safe emergency decision making in rivaroxaban- and dabigatran-treated patients. URL: http://www.clinicaltrials.gov. Unique identifiers: NCT02371044 and NCT02371070. © 2017 American Heart Association, Inc.

  4. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  5. An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation.

    PubMed

    Blasi, Annabel; Beltran, Joan; Pereira, Arturo; Martinez-Palli, Graciela; Torrents, Abiguei; Balust, Jaume; Zavala, Elizabeth; Taura, Pilar; Garcia-Valdecasas, Juan-Carlos

    2012-09-01

    Rotation thromboelastometry (TEM) has been proposed as a convenient alternative to standard coagulation tests in guiding the treatment of coagulopathy during orthotopic liver transplantation (OLT). This study was aimed at assessing the value of TEM in monitoring blood coagulation and guide transfusion support in OLT. Standard coagulation and TEM (EXTEM and FIBTEM) tests were performed at four preestablished intraoperative time points in 236 OLTs and prospectively recorded in a dedicated database together with the main operative and transfusion data. Transfusion thresholds were based on standard coagulation tests. Spearman's rank correlation (ρ), linear regression, and receiver operating characteristic curves were used when appropriate. EXTEM maximum clot firmness (MCF(EXTEM)) was the TEM variable that best correlated with the platelet (PLT) and fibrinogen levels (ρ = 0.62 and ρ = 0.69, respectively). MCF(FIBTEM) correlated with fibrinogen level (ρ = 0.70). EXTEM clot amplitude at 10 minutes (A10(EXTEM)) was a good linear predictor of MCF(EXTEM) (R(2) =0.93). The cutoff values that best predicted the transfusion threshold for PLTs and fibrinogen were A10(EXTEM) = 35 mm and A10(FIBTEM) = 8 mm. At these values, the negative and positive predictive accuracies of TEM to predict the transfusion thresholds were 95 and 27%, respectively. A10(EXTEM) is an adequate TEM variable to guide therapeutic decisions during OLT. Patients with A10(EXTEM) of greater than 35 mm are unlikely to bleed because of coagulation deficiencies, but using A10(EXTEM) of not more than 35 mm as the sole transfusion criterion can lead to unnecessary utilization of PLTs and fibrinogen-rich products. © 2012 American Association of Blood Banks.

  6. Removal of Heavy Metals from Solid Wastes Leachates Coagulation-Flocculation Process

    NASA Astrophysics Data System (ADS)

    Yousefi, Z.; Zazouli, M. A.

    The main objectives of present research were to determine heavy metals (Ni, Cd, Cr, Zn and Cu) and COD concentration in raw leachate in Esfahan (Iran) composting plant and to examine the application of coagulation-flocculation process for the treatment of raw leachates. Jar-test experiments were employed in order to determine the optimum conditions (effective dosage and optimum pH) for the removal of COD and heavy metals. Alum (aluminum sulphate) and Ferric chloride were tested as conventional coagulants. Ten times had taken sampling from leachates as standard methods in the composting plant prior to composting process. The results showed that Leachate pH was 4.3-5.9 and the average was 4.98±0.62. The concentration of Leachate pollutants were more than effluent standard limits (Environment protection Agency). And also the results indicated, Cd and Zn with concentration 0.46±0.41 and 5.81±3.69 mg L-1, had minimum and maximum levels, respectively. The results of coagulation and flocculation tests showed that in optimum conditions, the removal efficiency of heavy metals and COD by using alum were 77-91 and 21%, respectively. While removal of heavy metals and COD by ferric chloride were 68-85.5% and 28%, respectively. Also the residues of heavy metals after treatment get to under of standard limits of Iran EPA. The results have indicated optimum pH of two coagulants for leachate treatment was 6.5 and 10 and also effective coagulant dosages were 1400 and 1000 mg L-1 for alum and ferric chloride, respectively. In view of economical, ferric chloride is cost benefit. The physico-chemical process may be used as a useful pretreatment step, especially for fresh leachates.

  7. Effect of rivaroxaban on blood coagulation using the viscoelastic coagulation test ROTEM™.

    PubMed

    Casutt, M; Konrad, C; Schuepfer, G

    2012-11-01

    This study investigated the influence of the oral direct inhibitor of factor Xa rivaroxaban on blood coagulation measured by rotation thrombelastometry ROTEM™. Blood was obtained from 11 healthy male volunteers before and 2.5 h after oral administration of 10 mg rivaroxaban. In addition to standard coagulation tests clot formation was measured by ROTEM™ analyzing extrinsic (Extem) and intrinsic thrombelastometry (Intem). Significant differences to the baseline values were found in the Extem clotting time (Extem-CT, 58 ± 9 s and 87 ± 17 s, p < 0.01), Intem-CT (194 ± 26 s and 239 ± 43 s; p = 0.02), prothrombin time (PT, 86 ± 9% and 67 ± 7%; p < 0.01) and activated partial thromboplastin time (aPTT, 28 ± 1 s and 35 ± 2 s; p < 0.01). There was a low correlation between Extem-CT and PT as well as between Intem-CT and aPTT before and after rivaroxaban intake. The receiver operating characteristic curve (ROC) analysis determined aPTT to be the most appropriate parameter for the prediction of rivaroxaban-induced anticoagulation, Intem-CT and Extem-CT proved to be moderate tests and PT had no significance in the prediction of rivaroxaban-induced anticoagulation. Of utmost clinical importance was the fact that rivaroxaban treated patients could still show normal ROTEM™ values. Thus, ROTEM™ cannot be a suitable test method to exclude inhibition of blood coagulation by rivaroxaban.

  8. The use of aluminum oxychlorides to coagulate water having high content of organic impurities and low alkalinity

    NASA Astrophysics Data System (ADS)

    Evsyutin, A. V.; Boglovskii, A. V.

    2007-07-01

    Results from laboratory investigations and industrial tests of the coagulation of source water at the Pskov district power station are presented. It is shown that the source water may not be alkalified if it is treated with aluminum oxychlorides. As a result, the clarified water becomes less corrosive and a lower salt load is placed on water treatment plants as compared with the case when aluminum sulfate is used for coagulation.

  9. Coagulation monitoring during extracorporeal membrane oxygenation: the role of thrombelastography.

    PubMed

    Stammers, A H; Willett, L; Fristoe, L; Merrill, J; Stover, T; Hunt, A; Morrow, J; Newberry, J

    1995-09-01

    Patients undergoing extracorporeal membrane oxygenation (ECMO) are at an increased risk for developing coagulopathies due to the adverse effects of extracorporeal circulation on the hemostatic mechanism. Methods of determining causative factors of bleeding diathesis are often inconsistent and non-specific. ECMO patients require aggressive transfusion therapy with autogenic blood products to stabilize and maintain hemostasis. The present study evaluated the coagulation status of newborn patients undergoing ECMO therapy, using a viscoelastic monitor (Thrombelastograph -TEG) that measures functional aspects of clot development and stabilization. Seventeen neonatal patients undergoing ECMO for severe respiratory dysfunction were entered into this study. Serial blood samples were obtained and routine coagulation assessment including fibrinogen concentration, platelet count and ionized calcium was performed. In addition, fibrin(ogen) degradation products (FDP), d-Dimers, antithrombin III and plasma free hemoglobin were measured. Transfusion indicators were established and total transfusion requirements recorded. TEG profiles were determined with the use of heparinase, an enzyme that degrades heparin but has little effect on other coagulation factors. The most commonly encountered complication was hemorrhaging which was diagnosed by laboratory and clinical assessment in 11 of 17 patients. Transfusion requirements (measured in ml/kg/ECMO hour) were the following: packed red blood cells--1.34 +/- 0.5; platelets--0.71 +/- 0.57; fresh frozen plasma--0.09 +/- 0.12; cryoprecipitate 0.05 +/- 0.05. Thrombelastograph profiles reflected hemostatic conditions that ranged from severe coagulopathies (DIC) to hypercoagulability. Interpretation of TEG profiles identified hemostatic abnormalities in 57 of 101 profiles (46.5%), with the most common etiology related to platelet dysfunction.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Two distinct forms of Factor VIII coagulant protein in human plasma. Cleavage by thrombin, and differences in coagulant activity and association with von Willebrand factor.

    PubMed Central

    Weinstein, M J; Chute, L E

    1984-01-01

    We have characterized Factor VIII coagulant protein, present in normal human plasma, that reacts with a specific human 125I-labeled anti-human VIII:C antigen Fab antibody fragment. Two major Factor VIII coagulant antigen populations were present. The first, approximately 85% of the total antigen, was bound to von Willebrand factor and when tested in a standard one-stage assay had Factor VIII coagulant activity. The second antigenic population, eluting near fibrinogen when plasma was gel filtered, was not bound to von Willebrand protein, did not have Factor VIII coagulant activity unless activated, but did block anti-VIII:C Fab neutralization of clotting activity. The two antigenic populations were separable by cryoprecipitation and agarose gel electrophoresis. Although the two antigenic populations differed in their Factor VIII coagulant activity and in their binding to von Willebrand factor, the principal member of both populations is of mol wt 2.4 X 10(5). Both antigens, when proteolyzed by thrombin, were quickly converted to a 1 X 10(5)-mol wt form in association with the appearance of VIII:C activity. The 1 X 10(5)-mol wt antigen was further slowly degraded to an 8 X 10(4)-mol wt form while Factor VIII coagulant activity declined. These results demonstrate the presence of an inactive Factor VIII coagulant protein in plasma, not associated with von Willebrand factor, that can react with thrombin to yield Factor VIII coagulant activity. Images PMID:6421875

  11. Effect of circulating tissue factor on hypercoagulability in type 2 diabetes mellitus studied by rheometry and dielectric blood coagulometry.

    PubMed

    Uchimura, Isao; Kaibara, Makoto; Nagasawa, Masayuki; Hayashi, Yoshihito

    2016-01-01

    Hypercoagulability in type 2 diabetes mellitus (T2DM) patients increases their risk of cardiovascular diseases. The aim of this work was to investigate the hypercoagulation mechanism in T2DM patients in terms of circulating tissue factor (TF). Whole blood coagulation tests by damped oscillation rheometry and dielectric blood coagulometry (DBCM) were performed. The average coagulation time was significantly shorter for T2DM patients than for healthy controls. In vitro addition of either anti-TF or anti-activated factor VII (FVIIa) antibody to hypercoagulable blood samples prolonged coagulation times for one group of patients, while coagulation times remained short for another group. The levels of circulating TF were estimated in the former group by measuring the coagulation times for blood samples from healthy subjects with addition of various concentrations of TF and comparing them with the coagulation times for the group. The results indicated that the levels of circulating TF were on the order of subpicomolar at most. Circulating TF is at least partially responsible for a hypercoagulable group of T2DM patients, while an abnormality in the intrinsic coagulation pathway probably occurs in the other group.

  12. Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.

    PubMed

    Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao

    2006-01-01

    The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.

  13. Traumatic Coagulopathy: Where are the Good Experimental Models?

    DTIC Science & Technology

    2008-10-01

    XM, Tevaearai HT, Jegger D, Tucker O, von Segesser LK. Are standard human coagulation tests suitable in pigs and calves during extracorporeal ... circulation ? Artif Organs. 2001;25:579–584. 44. Karges HE, Funk KA, Ronneberger H. Activity of coagulation and fibrinolysis parameters in animals

  14. Fibrinogen Nový Jicín and Praha II: cases of hereditary Aalpha 16 Arg-->Cys and Aalpha 16 Arg-->His dysfibrinogenemia.

    PubMed

    Kotlín, Roman; Chytilová, Martina; Suttnar, Jirí; Riedel, Tomás; Salaj, Peter; Blatný, Jan; Santrůcek, Jirí; Klener, Pavel; Dyr, Jan E

    2007-01-01

    Various dysfibrinogenemias have been described worldwide. This paper describes two new cases of dysfibrinogenemia identified in the Czech Republic. The proposita of fibrinogen Nový Jicín, a 12-year-old girl, presented with hemorrhagic complications, low Clauss fibrinogen level (0.3 g/l) and prolonged both thrombin (70.8 s) and reptilase (>180 s) time. Her mother and sister both presented with normal coagulation tests, normal fibrinogen level and reported no history of bleeding. The carriers of the fibrinogen Praha II were a 31-year-old man and his 11-year-old daughter. They both presented with low fibrinogen Clauss level (0.88 g/l) and prolonged thrombin and reptilase time. To identify the genetic mutation responsible for these dysfibrinogens, genomic DNA extracted from the blood was analyzed. The presence of the mutant chains in the circulation was determined by MALDI-TOF mass spectroscopy. Scanning electron micrographs of the patients' fibrin clots were obtained. The kinetics of fibrinopeptide release and fibrin polymerization were impaired for both fibrinogen Nový Jicín and Praha II. DNA sequencing showed heterogeneous fibrinogen Aalpha R16C mutation in the fibrinogen Nový Jicín case and heterogeneous fibrinogen Aalpha R16H in the fibrinogen Praha II case. The mutant chains were found to be expressed to the circulation by MALDI-TOF mass spectroscopy. Scanning electron micrographs of the patient's fibrin clot were found to be abnormal. The case of dysfibrinogenemia Aalpha R16C-fibrinogen Nový Jicín and the case of dysfibrinogenemia Aalpha R16H were found by routine coagulation testing and were genetically identified.

  15. Reference Intervals of Routine Coagulation Assays During the Pregnancy and Puerperium Period.

    PubMed

    Gong, Jiao-Mei; Shen, Yong; He, Yan-Xia

    2016-11-01

    Significant changes occur in the coagulation and fibrinolytic systems during pregnancy and puerperium in the plasma levels. However, reference ranges based on healthy people are not optimal for informing clinical decisions during the pregnancy and puerperium. Therefore, it is essential to explore coagulation assays' reference ranges during the pregnancy and puerperium. Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib.), and D-dimer were all measured according to the manufacturer's specifications and laboratory standard operating procedure of the STA-R evolution coagulation analyzer. A total of 11,601 women were enrolled in this study. The reference ranges for PT, APTT, TT, Fib., and D-dimer in nonpregnancy period were 10.87-13.76 s, 29.22-44.61 s, 15.39-20.15 s, 1.59-3.97 g/l, and 0-0.56 mg/l, respectively. In early-pregnancy period, the ranges were 11.14-14.07 s, 29.97-44.69 s, 14.92-19.03 s, 1.98-4.13 g/l, and 0-1.67 mg/l, respectively. In midpregnancy period, the ranges were 9.98-12.84 s, 28.53-40.70 s, 13.51-19.82 s, 2.63-5.19 g/l, and 0-2.81 mg/l, respectively. In late-pregnancy period, the ranges were 9.48-12.58 s, 28.61-40.80 s, 14.10-19.61 s, 2.80-5.56 g/l, and 0-27.08 mg/l, respectively. In puerperium period, the ranges were 10.85-13.72 s, 30.51-43.02 s, 15.31-19.64 s, 1.14-5.07 g/l, and 1.27-4.85 mg/l, respectively. We presented reference intervals for coagulation assays from the nonpregnancy to puerperium period that can be adopted in other laboratories after further validation. © 2016 Wiley Periodicals, Inc.

  16. Determination of dabigatran, rivaroxaban and apixaban by ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) and coagulation assays for therapy monitoring of novel direct oral anticoagulants.

    PubMed

    Schmitz, E M H; Boonen, K; van den Heuvel, D J A; van Dongen, J L J; Schellings, M W M; Emmen, J M A; van der Graaf, F; Brunsveld, L; van de Kerkhof, D

    2014-10-01

    Three novel direct oral anticoagulants (DOACs) have recently been registered by the Food and Drug Administration and European Medicines Agency Commission: dabigatran, rivaroxaban, and apixaban. To quantify DOACs in plasma, various dedicated coagulation assays have been developed. To develop and validate a reference ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) method and to evaluate the analytical performance of several coagulation assays for quantification of dabigatran, rivaroxaban, and apixaban. The developed UPLC-MS/MS method was validated by determination of precision, accuracy, specificity, matrix effects, lower limits of detection, carry-over, recovery, stability, and robustness. The following coagulation assays were evaluated for accuracy and precision: laboratory-developed (LD) diluted thrombin time (dTT), Hemoclot dTT, Pefakit PiCT, ECA, Liquid anti-Xa, Biophen Heparin (LRT), and Biophen DiXal anti-Xa. Agreement between the various coagulation assays and UPLC-MS/MS was determined with random samples from patients using dabigatran or rivaroxaban. The UPLC-MS/MS method was shown to be accurate, precise, sensitive, stable, and robust. The dabigatran coagulation assay showing the best precision, accuracy and agreement with the UPLC-MS/MS method was the LD dTT test. For rivaroxaban, the anti-factor Xa assays were superior to the PiCT-Xa assay with regard to precision, accuracy, and agreement with the reference method. For apixaban, the Liquid anti-Xa assay was superior to the PiCT-Xa assay. Statistically significant differences were observed between the various coagulation assays as compared with the UPLC-MS/MS reference method. It is currently unknown whether these differences are clinically relevant. When DOACs are quantified with coagulation assays, comparison with a reference method as part of proficiency testing is therefore pivotal. © 2014 International Society on Thrombosis and Haemostasis.

  17. A data-driven approach for the study of coagulation phenomena in waste lubricant oils and its relevance in alkaline regeneration treatments.

    PubMed

    Pinheiro, C T; Ascensão, V R; Reis, M S; Quina, M J; Gando-Ferreira, L M

    2017-12-01

    Coagulation phenomena can occur in certain types of waste lubricant oils (WLO) during regeneration processes involving alkaline treatments, causing plant shutdowns. In this context, this study addresses the nature of the compounds responsible for the coagulation phenomena after the alkaline treatment. For such, an empirical test was developed to assess the coagulation behaviour of WLO, consisting in the addition of KOH to the WLO followed by heating under stirring conditions. This test was performed on 133 samples and four coagulation classes were identified: A; B1; B2 and C. Moreover, a physicochemical characterization of WLO was carried out regarding viscosity at 40°C, saponification number (SN), total acid number (TAN), surface tension, water content, elemental analysis and functional groups (FTIR). 56 samples of fresh lubricant oils for different applications were also characterized and their properties assessed and compared. Multivariate methods were applied to WLO to discriminate among coagulation classes based on FTIR spectra. It was found that coagulation classes A and B1 exhibit statistically similar patterns for all properties determined. Spectral discriminating analysis did not reveal discriminant peaks for class B1 samples, and the presence of specific additives was pointed as the possible factor underlying the increase in viscosity in this oils. Class B2 presents the absence of additives and oxidation products as differentiating features. In addition, B2 samples showed lower TAN SN, and lower concentration of some elements. Lubricants from gear or hydraulic applications can give rise to this class of WLO. Oils of Class C are mainly composed by synthetic ester type base oils, which hamper regeneration processes using alkaline pretreatments. In future studies, WLO type A and B1 can be classified as a single class. The coagulation phenomena classification becomes A - negative, B - precipitate formation and C - positive. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Evaluation of geotextile filtration applying coagulant and flocculant amendments for aquaculture biosolids dewatering and phosphorus removal

    USDA-ARS?s Scientific Manuscript database

    Wastes contained in the microscreen backwash discharged from intensive recirculating aquaculture systems were removed and dewatered in simple geotextile bag filters. Three chemical coagulation aids, (aluminum sulfate (alum), ferric chloride, and calcium hydroxide (hydrated lime)), were tested in com...

  19. Enhanced Coagulation-Flocculation Performance of Iron-Based Coagulants: Effects of PO4 3- and SiO3 2- Modifiers

    PubMed Central

    Teng, Houkai; Wang, Yili; Zhang, Yuxin; Zhao, Chuanliang; Liao, Yong

    2015-01-01

    PO4 3- and SiO3 2- are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants—polyferric phosphoric sulfate (PFPS), polysilicon ferric sulfate (PFSS), and polyferric sulfate (PFS) were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) and Scanning electron microscope (SEM). Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4 3- and SiO3 2-. Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond. PMID:26339902

  20. Influence of blood lipids on global coagulation test results.

    PubMed

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon; Kim, Hyun Kyung

    2015-01-01

    High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels.

  1. Influence of Blood Lipids on Global Coagulation Test Results

    PubMed Central

    Kim, Jung-Ah; Kim, Ji-Eun; Song, Sang Hoon

    2015-01-01

    Background High levels of blood lipids have been associated with high levels of coagulation factors. We investigated whether blood lipids influence the results of global coagulation tests, including prothrombin time (PT), activated partial thromboplastin time (aPTT), and thrombin generation assay (TGA). Methods PT, aPTT, and TGA, along with procoagulant and anticoagulant factors, were measured in 488 normal individuals. Vitamin K status was assessed with prothrombin-induced by vitamin K absence-II (PIVKA-II). Results The procoagulant factors II, VII, IX, X, and XI and anticoagulant factors protein C and protein S showed significant correlations with triglyceride, and the procoagulant factors II, V, VII, IX, X, XI, and XII and anticoagulant factors antithrombin and protein C correlated with total cholesterol. There were no correlations of blood lipid levels with PIVKA-II levels. Subjects with high triglyceride levels (≥200 mg/dL) showed shorter PT values than those with lower triglyceride levels. However, aPTT value was not changed in terms of blood lipid levels. In both 1 and 5 pM tissue factor-induced TGAs, subjects in the high-triglyceride or high-cholesterol groups (≥240 mg/dL) had high levels of lag time, time-to-peak, and endogenous thrombin potential. Total cholesterol was a significant determinant of PT and TGA values. Conclusion High blood lipids were related with increased coagulation activity in a normal population. Our findings are expected to help interpret the global coagulation test results in individuals with high lipid levels. PMID:25553275

  2. Assessment of coagulation in the obstetric population using ROTEM® thromboelastometry.

    PubMed

    Armstrong, S; Fernando, R; Ashpole, K; Simons, R; Columb, M

    2011-10-01

    Assessment of maternal coagulation to determine suitability for neuraxial anaesthesia and management of obstetric haemorrhage remains a challenge. Thromboelastography provides point of care patient assessment of the viscoelastic properties of whole blood clotting and can assist the clinician in haemostatic decision-making. The study aim was to determine the ROTEM® thromboelastometer 95% reference limits for third trimester parturients and to compare these with non-pregnant female controls. Following ethics committee approval and informed consent, citrated blood was sampled from 120 age-matched healthy pregnant and non-pregnant women. Thromboelastometry, using a ROTEM® point of care monitor, was performed with specific activators to measure the coagulation time (CT), clot formation time (CFT) and the maximal clot firmness (MCF) in order to evaluate the extrinsic (EXTEM® test) and intrinsic (INTEM® test) coagulation systems, as well as the fibrinogen contribution to coagulation (FIBTEM® test). After exclusions, data from 54 subjects in each group were analysed. Parturients had significantly lower haemoglobin values and platelet counts (P<0.01). Despite this, thromboelastometry exhibited significantly lower INTEM® CT (7.3%), INTEM® CFT (11.1%) and EXTEM® CFT (18.0%) in the pregnant group (P<0.001). MCF values were significantly higher (INTEM® (10.9%), EXTEM® (10.6%) and FIBTEM® (47.1%)) in the pregnant group compared to the non-pregnant group (P<0.0001). ROTEM® thromboelastometry clearly demonstrates the hypercoagulability of pregnancy. Formal reference ranges for ROTEM® that may be potentially useful in the haemostatic management of the parturient are presented. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Vitamin K supplementation for cystic fibrosis.

    PubMed

    Jagannath, Vanitha A; Fedorowicz, Zbys; Thaker, Vidhu; Chang, Anne B

    2015-01-18

    Cystic fibrosis is a genetic disorder which can lead to multiorgan dysfunction. Malabsorption of fat and fat-soluble vitamins (A, D, E, K) may occur and can cause subclinical deficiencies of some of these vitamins. Vitamin K is known to play an important role in both blood coagulation and bone formation. Supplementation with vitamin K appears to be one way of addressing the deficiency, but there is very limited agreement on the appropriate dose and frequency of use of these supplements. To assess the effects of vitamin K supplementation in people with cystic fibrosis and to determine the optimal dose and route of administration of vitamin K for both routine and therapeutic use. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group's Trials Register comprising references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Most recent search: 08 October 2014. Randomised and quasi-randomised controlled trials of all preparations of vitamin K used as a supplement compared to either no supplementation (or placebo) at any dose or route and for any duration, in children or adults diagnosed with cystic fibrosis (by sweat test or genetic testing). Two authors independently screened papers, extracted trial details and assessed their risk of bias. Two trials (total of 32 participants) each lasting one month were included in the review and were assessed as having a moderate risk of bias. One was a dose-ranging parallel group trial in children (aged 8 to 18 years); and the other (with an older cohort) had a cross-over design comparing supplements to no treatment, but no separate data were reported for the first intervention period. Neither of the trials addressed any of the primary outcomes (coagulation, bone formation and quality of life). Both trials reported the restoration of serum vitamin K and undercarboxylated osteocalcin levels to the normal range after one month of daily supplementation with 1 mg of vitamin K. Evidence from randomised controlled trials on the benefits of routine vitamin K supplementation for people with CF is currently weak and limited to two small trials of short duration. However, no harm was found and until further evidence is available, the present recommendations should be adhered to.

  4. Vitamin K supplementation for cystic fibrosis.

    PubMed

    Jagannath, Vanitha A; Thaker, Vidhu; Chang, Anne B; Price, Amy I

    2017-08-22

    Cystic fibrosis is a genetic disorder which can lead to multiorgan dysfunction. Malabsorption of fat and fat-soluble vitamins (A, D, E, K) may occur and can cause subclinical deficiencies of some of these vitamins. Vitamin K is known to play an important role in both blood coagulation and bone formation. Supplementation with vitamin K appears to be one way of addressing the deficiency, but there is very limited agreement on the appropriate dose and frequency of use of these supplements. This is an updated version of the review. To assess the effects of vitamin K supplementation in people with cystic fibrosis and to determine the optimal dose and route of administration of vitamin K for both routine and therapeutic use. We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group's Trials Register comprising references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings.Most recent search: 30 January 2017. Randomised and quasi-randomised controlled trials of all preparations of vitamin K used as a supplement compared to either no supplementation (or placebo) at any dose or route and for any duration, in children or adults diagnosed with cystic fibrosis (by sweat test or genetic testing). Two authors independently screened papers, extracted trial details and assessed their risk of bias. Two trials (total of 32 participants) each lasting one month were included in the review and were assessed as having a moderate risk of bias. One was a dose-ranging parallel group trial in children (aged 8 to 18 years); and the other (with an older cohort) had a cross-over design comparing supplements to no treatment, but no separate data were reported for the first intervention period. Neither of the trials addressed any of the primary outcomes (coagulation, bone formation and quality of life). Both trials reported the restoration of serum vitamin K and undercarboxylated osteocalcin levels to the normal range after one month of daily supplementation with 1 mg of vitamin K. Evidence from randomised controlled trials on the benefits of routine vitamin K supplementation for people with CF is currently weak and limited to two small trials of short duration. However, no harm was found and until further evidence is available, the present recommendations should be adhered to.

  5. Vitamin K supplementation for cystic fibrosis

    PubMed Central

    Jagannath, Vanitha A; Fedorowicz, Zbys; Thaker, Vidhu; Chang, Anne B

    2015-01-01

    Background Cystic fibrosis is a genetic disorder which can lead to multiorgan dysfunction. Malabsorption of fat and fat-soluble vitamins (A, D, E, K) may occur and can cause subclinical deficiencies of some of these vitamins. Vitamin K is known to play an important role in both blood coagulation and bone formation. Supplementation with vitamin K appears to be one way of addressing the deficiency, but there is very limited agreement on the appropriate dose and frequency of use of these supplements. Objectives To assess the effects of vitamin K supplementation in people with cystic fibrosis and to determine the optimal dose and route of administration of vitamin K for both routine and therapeutic use. Search methods We searched the Cochrane Cystic Fibrosis and Genetic Disorders Group’s Trials Register comprising references identified from comprehensive electronic database searches and handsearches of relevant journals and abstract books of conference proceedings. Most recent search: 08 October 2014. Selection criteria Randomised and quasi-randomised controlled trials of all preparations of vitamin K used as a supplement compared to either no supplementation (or placebo) at any dose or route and for any duration, in children or adults diagnosed with cystic fibrosis (by sweat test or genetic testing). Data collection and analysis Two authors independently screened papers, extracted trial details and assessed their risk of bias. Main results Two trials (total of 32 participants) each lasting one month were included in the review and were assessed as having a moderate risk of bias. One was a dose-ranging parallel group trial in children (aged 8 to 18 years); and the other (with an older cohort) had a crossover design comparing supplements to no treatment, but no separate data were reported for the first intervention period. Neither of the trials addressed any of the primary outcomes (coagulation, bone formation and quality of life). Both trials reported the restoration of serum vitamin K and undercarboxylated osteocalcin levels to the normal range after one month of daily supplementation with 1 mg of vitamin K. Authors’ conclusions Evidence from randomised controlled trials on the benefits of routine vitamin K supplementation for people with CF is currently weak and limited to two small trials of short duration. However, no harm was found and until further evidence is available, the present recommendations should be adhered to. PMID:25879106

  6. Testing of Intravenous Hemostatic Agents in a Novel Swine Model of Bleeding: Preliminary Results With FXa-PCPs

    DTIC Science & Technology

    2005-08-01

    proceeds through a prothrombinase complex (prothrombin, factor Va, calcium, and phospholipid). Thrombin is the final product in the coagulation cascade...we report preliminary data on the efficacy of mixtures of highly purified blood coagulation factors (FVIIa and FXa) and phospholipids vesicles (PCPS...testing. Further study of these drugs for the use of traumatic hemorrhage is not warranted. 15. SUBJECT TERMS Recombinant Factor VI~a, factor Xa

  7. Precoagulation-microfiltration for wastewater reuse.

    PubMed

    Hatt, J W; Germain, E; Judd, S J

    2011-12-01

    A range of coagulant chemicals and doses, up to 2 mg/L, were trialled on a microfiltration-based indirect potable reuse (IPR) pilot plant to evaluate their impact on membrane reversible and irreversible fouling. Jar tests revealed these doses to have negligible impact on organic matter removal, whilst scoping pilot trials showed them to have a positive impact on fouling rates. Initial trials carried out over a 6-h period suggested that ferric sulphate was the most promising of the coagulants tested with regards to irreversible fouling. Extended five-day trials using ferric sulphate at 0.5 mg/L were conducted at fluxes of 40-50 l/(m(2)h) (LMH). Operation at 50 LMH without coagulant resulted in rapid fouling and a subsequent shortening of the chemical cleaning interval. The addition of the ferric coagulant resulted in a reduction in both reversible and irreversible fouling to those levels experienced at 40 LMH, enabling sustainable operation. The use of low levels of coagulant thus enables the pilot plant to operate at a 25% increased flux, equating to a 20% reduction in membrane area and overall savings of >0.1 p per m(3) for a seven year membrane life. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Purification and characterization of a heteromultimeric glycoprotein from Artocarpus heterophyllus latex with an inhibitory effect on human blood coagulation.

    PubMed

    Siritapetawee, Jaruwan; Thammasirirak, Sompong

    2011-01-01

    Plant latex has many health benefits and has been used in folk medicine. In this study, the biological effect of Artocarpus heterophyllus (jackfruit) latex on human blood coagulation was investigated. By a combination of heat precipitation and ion-exchange chromatography, a heat stable heteromultimeric glycoprotein (HSGPL1) was purified from jackfruit milky latex. The apparent molecular masses of the monomeric proteins on SDS/PAGE were 33, 31 and 29 kDa. The isoelectric points (pIs) of the monomers were 6.63, 6.63 and 6.93, respectively. Glycosylation and deglycosylation tests confirmed that each subunit of HSGPL1 formed the native multimer by sugar-based interaction. Moreover, the multimer of HSGPL1 also resisted 2-mercaptoethanol action. Peptide mass fingerprint analysis indicated that HSGPL1 was a complex protein related to Hsps/chaperones. HSGPL1 has an effect on intrinsic pathways of the human blood coagulation system by significantly prolonging the activated partial thrombin time (APTT). In contrast, it has no effect on the human extrinsic blood coagulation system using the prothrombin time (PT) test. The prolonged APTT resulted from the serine protease inhibitor property of HSGPL1, since it reduced activity of human blood coagulation factors XI(a) and α-XII(a).

  9. The Interplay between Inflammation, Coagulation and Endothelial Injury in the Early Phase of Acute Pancreatitis: Clinical Implications

    PubMed Central

    Dumnicka, Paulina; Maduzia, Dawid; Ceranowicz, Piotr; Olszanecki, Rafał; Drożdż, Ryszard; Kuśnierz-Cabala, Beata

    2017-01-01

    Acute pancreatitis (AP) is an inflammatory disease with varied severity, ranging from mild local inflammation to severe systemic involvement resulting in substantial mortality. Early pathologic events in AP, both local and systemic, are associated with vascular derangements, including endothelial activation and injury, dysregulation of vasomotor tone, increased vascular permeability, increased leukocyte migration to tissues, and activation of coagulation. The purpose of the review was to summarize current evidence regarding the interplay between inflammation, coagulation and endothelial dysfunction in the early phase of AP. Practical aspects were emphasized: (1) we summarized available data on diagnostic usefulness of the markers of endothelial dysfunction and activated coagulation in early prediction of severe AP; (2) we reviewed in detail the results of experimental studies and clinical trials targeting coagulation-inflammation interactions in severe AP. Among laboratory tests, d-dimer and angiopoietin-2 measurements seem the most useful in early prediction of severe AP. Although most clinical trials evaluating anticoagulants in treatment of severe AP did not show benefits, they also did not show significantly increased bleeding risk. Promising results of human trials were published for low molecular weight heparin treatment. Several anticoagulants that proved beneficial in animal experiments are thus worth testing in patients. PMID:28208708

  10. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.

    PubMed

    Lima-Oliveira, G; Salvagno, G L; Danese, E; Favaloro, E J; Guidi, G C; Lippi, G

    2015-06-01

    The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen. Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. © 2014 John Wiley & Sons Ltd.

  11. Sudden sensorineural hearing loss: is there a relationship between routine haematological parameters and audiogram shapes?

    PubMed

    Salvago, Pietro; Rizzo, Serena; Bianco, Antonino; Martines, Francesco

    2017-03-01

    To investigate the relationship between haematological routine parameters and audiogram shapes in patients affected by sudden sensorineural hearing loss (SSNHL). A retrospective study. All patients were divided into four groups according to the audiometric curve and mean values of haematological parameters (haemoglobin, white blood cell, neutrophils and lymphocytes relative count, platelet count, haematocrit, prothrombin time, activated partial thromboplastin time, fibrinogen and neutrophil-to-lymphocite ratio) of each group were statistically compared. The prognostic role of blood profile and coagulation test was also examined. A cohort of 183 SSNHL patients without comorbidities. With a 48.78% of complete hearing recovery, individuals affected by upsloping hearing loss presented a better prognosis instead of flat (18.36%), downsloping (19.23%) and anacusis (2.45%) groups (p = 0.0001). The multivariate analysis of complete blood count values revealed lower mean percentage of lymphocytes (p = 0.041) and higher platelet levels (p = 0.015) in case of downsloping hearing loss; with the exception of fibrinogen (p = 0.041), none of the main haematological parameters studied resulted associated with poorer prognosis. Our work suggested a lack of association between haematological parameters and a defined audiometric picture in SSNHL patients; furthermore, only fibrinogen seems to influence the prognosis of this disease.

  12. Prediction of coagulation and flocculation processes using ANN models and fuzzy regression.

    PubMed

    Zangooei, Hossein; Delnavaz, Mohammad; Asadollahfardi, Gholamreza

    2016-09-01

    Coagulation and flocculation are two main processes used to integrate colloidal particles into larger particles and are two main stages of primary water treatment. Coagulation and flocculation processes are only needed when colloidal particles are a significant part of the total suspended solid fraction. Our objective was to predict turbidity of water after the coagulation and flocculation process while other parameters such as types and concentrations of coagulants, pH, and influent turbidity of raw water were known. We used a multilayer perceptron (MLP), a radial basis function (RBF) of artificial neural networks (ANNs) and various kinds of fuzzy regression analysis to predict turbidity after the coagulation and flocculation processes. The coagulant used in the pilot plant, which was located in water treatment plant, was poly aluminum chloride. We used existing data, including the type and concentrations of coagulant, pH and influent turbidity, of the raw water because these types of data were available from the pilot plant for simulation and data was collected by the Tehran water authority. The results indicated that ANNs had more ability in simulating the coagulation and flocculation process and predicting turbidity removal with different experimental data than did the fuzzy regression analysis, and may have the ability to reduce the number of jar tests, which are time-consuming and expensive. The MLP neural network proved to be the best network compared to the RBF neural network and fuzzy regression analysis in this study. The MLP neural network can predict the effluent turbidity of the coagulation and the flocculation process with a coefficient of determination (R 2 ) of 0.96 and root mean square error of 0.0106.

  13. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-02-15

    The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken.

  14. Policies and practices in haemostasis testing among laboratories in Croatia: a survey on behalf of a Working Group for Laboratory Coagulation of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Bronić, Ana; Herak, Desiree Coen; Margetić, Sandra; Milić, Marija

    2017-01-01

    Introduction The objective of this survey was to assess current policies and practice in haemostasis testing among both hospital and outpatient laboratories in Republic of Croatia. Materials and methods A questionnaire with seventy questions divided into nine sections was created in May 2015. Participants were asked about their practice related to test request form, sample collection, prothrombin time (PT) and activated partial thromboplastin time assays, other individual haemostasis assays, point-of-care testing (POCT), reporting of coagulation tests results and quality assurance of procedures, the personnel and other laboratory resources, as well as on issues related to education and implementation of additional coagulation assays in their laboratory. The survey was administered and data were collected between June and September 2015. Results A total survey response rate was 104/170 (61.2%). Most respondents were faced with incomplete information on prescribed therapy and diagnosis on the test request or inappropriate samples withdrawn on distant locations, but also do not have protocols for handling samples with high haematocrit values. Reporting of PT-INR and D-dimer results was different between laboratories. Although almost all laboratories developed a critical value reporting system, reporting a value to general practitioners is still a problem. Result on coagulation POCT testing showed that not all devices were supervised by laboratories, which is not in compliance with Croatian Chamber of Medical Biochemistry acts. Conclusion Obtained results highlighted areas that need improvement and different practice patterns in particular field of haemostasis testing among laboratories. A harmonization of the overall process of haemostasis testing at national level should be considered and undertaken. PMID:28392741

  15. Antithrombotic Protective Effects of Arg-Pro-Gly-Pro Peptide during Emotional Stress Provoked by Forced Swimming Test in Rats.

    PubMed

    Grigor'eva, M E; Lyapina, L A

    2017-01-01

    Blood coagulation was enhanced and all factors (total, enzyme, and non-enzyme) of the fibrinolytic system were suppressed in rats in 60 min after forced swimming test. Argininecontaining tetrapeptide glyproline Arg-Pro-Gly-Pro administered prior to this test activated fibrinolysis and prevented hypercoagulation. Administration of this peptide in 5 min after swimming test also enhanced anticoagulant, fibrinolytic, and antithrombotic activity of the blood. Therefore, glyproline Arg-Pro-Gly-Pro exerted both preventive and curative effects on the hemostasis system and prevented enhancement of blood coagulation provoked by emotional stress modeled by forced swimming test.

  16. Multipurpose HTS Coagulation Analysis: Assay Development and Assessment of Coagulopathic Snake Venoms

    PubMed Central

    Still, Kristina B. M.; Nandlal, Randjana S. S.; Slagboom, Julien; Somsen, Govert W.; Kool, Jeroen

    2017-01-01

    Coagulation assays currently employed are often low throughput, require specialized equipment and/or require large blood/plasma samples. This study describes the development, optimization and early application of a generic low-volume and high-throughput screening (HTS) assay for coagulation activity. The assay is a time-course spectrophotometric measurement which kinetically measures the clotting profile of bovine or human plasma incubated with Ca2+ and a test compound. The HTS assay can be a valuable new tool for coagulation diagnostics in hospitals, for research in coagulation disorders, for drug discovery and for venom research. A major effect following envenomation by many venomous snakes is perturbation of blood coagulation caused by haemotoxic compounds present in the venom. These compounds, such as anticoagulants, are potential leads in drug discovery for cardiovascular diseases. The assay was implemented in an integrated analytical approach consisting of reversed-phase liquid chromatography (LC) for separation of crude venom components in combination with parallel post-column coagulation screening and mass spectrometry (MS). The approach was applied for the rapid assessment and identification of profiles of haemotoxic compounds in snake venoms. Procoagulant and anticoagulant activities were correlated with accurate masses from the parallel MS measurements, facilitating the detection of peptides showing strong anticoagulant activity. PMID:29186818

  17. [Combined use of active chlorine and coagulants for drinking water purification and disinfection].

    PubMed

    Rakhmanin, Iu A; Zholdakova, Z I; Poliakova, E E; Kir'ianova, L F; Miasnikov, I N; Tul'skaia, E A; Artemova, T Z; Ivanova, L V; Dmitrieva, R A; Doskina, T V

    2004-01-01

    The authors made an experimental study of the efficiency of water purification procedures based on the combined use of active chlorine and coagulants and hygienically evaluated the procedures. The study included the evaluation of water disinfection with various coagulants and active chlorine; the investigation of the processes of production of deleterious organic chlorine compounds; the assessment of the quality of water after its treatment. The coagulants representing aluminum polyoxychloride: RAX-10 (AQUA-AURATE 10) and RAX-18 (AQUA-AURATE 18), and aluminum sulfate, technically pure grade were tested. The treatment of river water with the coagulants RAX-10 and RAX-18, followed by precipitation, filtration, and chlorination under laboratory conditions, was shown to result in water disinfection to the levels complying with the requirements described in SanPiN 2.1.4.1074-01. RAX-18 showed the best disinfecting activity against total and heat-tolerant coliform bacteria, but also to the highly chlorine-resistant microrganisms--the spores of sulfite-reducing Clostridia, phages, and viruses. Since the coagulants have an increased sorptive capacity relative to humus and other organic substances, substitution of primary chlorination for coagulant treatment may induce a reduction in the risk of formation of oncogenically and mutagenically hazardous chlorinated hydrocarbons.

  18. Effect of circulating tissue factor on hypercoagulability in type 2 diabetes mellitus studied by rheometry and dielectric blood coagulometry

    PubMed Central

    Uchimura, Isao; Kaibara, Makoto; Nagasawa, Masayuki; Hayashi, Yoshihito

    2016-01-01

    Background: Hypercoagulability in type 2 diabetes mellitus (T2DM) patients increases their risk of cardiovascular diseases. Objective: The aim of this work was to investigate the hypercoagulation mechanism in T2DM patients in terms of circulating tissue factor (TF). Methods: Whole blood coagulation tests by damped oscillation rheometry and dielectric blood coagulometry (DBCM) were performed. Results: The average coagulation time was significantly shorter for T2DM patients than for healthy controls. In vitro addition of either anti-TF or anti-activated factor VII (FVIIa) antibody to hypercoagulable blood samples prolonged coagulation times for one group of patients, while coagulation times remained short for another group. The levels of circulating TF were estimated in the former group by measuring the coagulation times for blood samples from healthy subjects with addition of various concentrations of TF and comparing them with the coagulation times for the group. The results indicated that the levels of circulating TF were on the order of subpicomolar at most. Conclusions: Circulating TF is at least partially responsible for a hypercoagulable group of T2DM patients, while an abnormality in the intrinsic coagulation pathway probably occurs in the other group. PMID:27858671

  19. Removal of inorganic mercury and methylmercury from surface waters following coagulation of dissolved organic matter with metal-based salts

    USGS Publications Warehouse

    Henneberry, Y.K.; Kraus, T.E.C.; Fleck, J.A.; Krabbenhoft, D.P.; Bachand, P.M.; Horwath, W.R.

    2011-01-01

    The presence of inorganic mercury (IHg) and methylmercury (MeHg) in surface waters is a health concern worldwide. This study assessed the removal potential use of metal-based coagulants as a means to remove both dissolved IHg and MeHg from natural waters and provides information regarding the importance of Hg associations with the dissolved organic matter (DOM) fraction and metal hydroxides. Previous research indicated coagulants were not effective at removing Hg from solution; however these studies used high concentrations of Hg and did not reflect naturally occurring concentrations of Hg. In this study, water collected from an agricultural drain in the Sacramento-San Joaquin Delta was filtered to isolate the dissolved organic matter (DOM) fraction. The DOM was then treated with a range of coagulant doses to determine the efficacy of removing all forms of Hg from solution. Three industrial-grade coagulants were tested: ferric chloride, ferric sulfate, and polyaluminum chloride. Coagulation removed up to 85% of DOM from solution. In the absence of DOM, all three coagulants released IHg into solution, however in the presence of DOM the coagulants removed up to 97% of IHg and 80% of MeHg. Results suggest that the removal of Hg is mediated by DOM-coagulant interactions. There was a preferential association of IHg with the more aromatic, higher molecular weight fraction of DOM but no such relationship was found for MeHg. This study offers new fundamental insights regarding large-scale removal of Hg at environmentally relevant regarding large-scale removal of Hg at environmentally relevant concentrations.

  20. Coagulation chemistries for silica removal from cooling tower water.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom

    2010-02-01

    The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants deliveredmore » promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.« less

  1. An optical approach for non-invasive blood clot testing

    NASA Astrophysics Data System (ADS)

    Kalchenko, Vyacheslav; Brill, Alexander; Fine, Ilya; Harmelin, Alon

    2007-02-01

    Physiological blood coagulation is an essential biological process. Current tests for plasma coagulation (clotting) need to be performed ex vivo and require fresh blood sampling for every test. A recently published work describes a new, noninvasive, in vivo approach to assess blood coagulation status during mechanical occlusion1. For this purpose, we have tested this approach and applied a controlled laser beam to blood micro-vessels of the mouse ear during mechanical occlusion. Standard setup for intravital transillumination videomicroscopy and laser based imaging techniques were used for monitoring the blood clotting process. Temporal mechanical occlusion of blood vessels in the observed area was applied to ensure blood flow cessation. Subsequently, laser irradiation was used to induce vascular micro-injury. Changes in the vessel wall, as well as in the pattern of blood flow, predispose the area to vascular thrombosis, according to the paradigm of Virchow's triad. In our experiments, two elements of Virchow's triad were used to induce the process of clotting in vivo, and to assess it optically. We identified several parameters that can serve as markers of the blood clotting process in vivo. These include changes in light absorption in the area of illumination, as well as changes in the pattern of the red blood cells' micro-movement in the vessels where blood flow is completely arrested. Thus, our results indicate that blood coagulation status can be characterized by non-invasive, in vivo methodologies.

  2. Comparison of coagulation pretreatment of produced water from natural gas well by polyaluminium chloride and polyferric sulphate coagulants.

    PubMed

    Zhai, Jun; Huang, Zejin; Rahaman, Md Hasibur; Li, Yue; Mei, Longyue; Ma, Hongpu; Hu, Xuebin; Xiao, Haiwen; Luo, Zhiyong; Wang, Kunping

    2017-05-01

    This study aimed to optimise coagulation pretreatment of the produced water (PW) collected from a natural gas field. Two coagulants, polyferric sulphate (PFS) and polyaluminium chloride (PACl), were applied separately for the organics, suspended solids (SS), and colour removal. Treatment performance at different coagulant dosages, initial pH values, stirring patterns, and the addition of cationic polyacrylamide (PAM) was investigated in jar tests. The optimal coagulation conditions were dosage of PACl 25 g/L or PFS 20 g/L with that of PAM 30 mg/L, initial pH of 11, and fast mixing of 1.5 min (for PACl) or 2 min (for PFS) at 250 rpm followed by slow mixing of 15 min at 50 rpm for both coagulants. PACl performed better than PFS to remove chemical oxygen demand (COD), total organic carbon (TOC), SS, and colour, and achieved a removal efficiency of 90.1%, 89.4%, 99.0%, and 99.9%, respectively, under the optimal condition; while PFS efficiency was 86.1%, 86.1%, 99.0%, and 98.2%, respectively. However, oil removal was higher in PFS coagulation compared to PACl and showed 98.9% and 95.3%, respectively. Biodegradability, ratio of the biological oxygen demand (five-day) (BOD 5 )/COD, of the PW after pretreatment increased from 0.08 to 0.32 for PFS and 0.43 for PACl. Zeta potential (Z-potential) analysis at the optimum coagulant dosage of PACl and PFS suggests that charge neutralisation was the predominant mechanism during coagulation. Better efficiency was observed at higher pH. The addition of PAM and starring pattern had a minor influence on the removal performance of both coagulants. The results suggest that PACl or PFS can be applied for the pretreatment of PW, which can provide substantial removal of carbon, oil, and colour, a necessary first step for subsequent main treatment units such as chemical oxidation or biological treatment.

  3. Haemothorax associated with Angiostrongylus vasorum infection in a dog.

    PubMed

    Sasanelli, M; Paradies, P; Otranto, D; Lia, R P; de Caprariis, D

    2008-08-01

    Angiostrongylosis was diagnosed in a dog presenting with haemothorax on the basis of detection of Angiostrongylus vasorum first-stage larvae both in the pleural effusion and in faeces. A one-year-old, male, mixed-breed dog was presented with fever, depression and persistent cough of one month's duration. Clinical examination revealed temperature of 39.5 degrees C, loud bronchovesicular sounds on thoracic auscultation and attenuated cardiac sounds. Thoracic radiographs showed a moderate bilateral pleural effusion and a diffuse interstitial pulmonary pattern, with an alveolar pattern in one lobe. Routine haematology revealed anaemia and leucocytosis with eosinophilia, basophilia and thrombocytopenia. Coagulation assays showed a consumptive coagulopathy resembling disseminated intravascular coagulation. The relationship between haemothorax and the presence of A vasorum larvae in the pleural effusion is discussed. The dog was successfully treated with fenbendazole until negative for larvae on faecal examination. This case report indicates that A vasorum infection should be considered as a possible aetiological cause of haemothorax in dogs.

  4. ETV REPORT: REMOVAL OF ARSENIC IN DRINKING WATER ORCA WATER TECHNOLOGIES KEMLOOP 1000 COAGULATION AND FILTRATION WATER TREATMENT SYSTEM

    EPA Science Inventory

    Verification testing of the ORCA Water Technologies KemLoop 1000 Coagulation and Filtration Water Treatment System for arsenic removal was conducted at the St. Louis Center located in Washtenaw County, Michigan, from March 23 through April 6, 2005. The source water was groundwate...

  5. The Coagulation Profile of End-Stage Liver Disease and Considerations for Intraoperative Management.

    PubMed

    Forkin, Katherine T; Colquhoun, Douglas A; Nemergut, Edward C; Huffmyer, Julie L

    2018-01-01

    The coagulopathy of end-stage liver disease results from a complex derangement in both anticoagulant and procoagulant processes. With even minor insults, cirrhotic patients experience either inappropriate bleeding or clotting, or even both simultaneously. The various phases of liver transplantation along with fluid and blood product administration may contribute to additional disturbances in coagulation. Thus, anesthetic management of patients undergoing liver transplantation to improve hemostasis and avoid inappropriate thrombosis in the perioperative environment can be challenging. To add to this challenge, traditional laboratory tests of coagulation are difficult to interpret in patients with end-stage liver disease. Viscoelastic coagulation tests such as thromboelastography (Haemonetics Corporation, Braintree, MA) and rotational thromboelastometry (TEM International, Munich, Germany) have helped to reduce transfusion of allogeneic blood products, especially fresh frozen plasma, but have also lead to the increased use of fibrinogen-containing products. In general, advancements in surgical techniques and anesthetic management have led to significant reduction in blood transfusion requirements during liver transplantation. Targeted transfusion protocols and pharmacologic prevention of fibrinolysis may further aid in the management of the complex coagulopathy of end-stage liver disease.

  6. A novel use of Moringa oleifera seed powder in enhancing the primary treatment of paper mill effluent.

    PubMed

    Boulaadjoul, Soumia; Zemmouri, Hassiba; Bendjama, Zoubida; Drouiche, Nadjib

    2018-05-02

    In this study, Moringa oleifera (M. oleifera) performance as an eco-friendly coagulant in the enhanced primary treatment of paper mill effluent was investigated. Its performance in terms of turbidity removal and COD abatement was examined. Local M. oleifera seed powder from ADRAR-city, South of Algeria, was used. Conventional jar tests were conducted for enhancing the primary treatment of paper mill effluent from paper factory. For this reason, comparative coagulation tests were performed using aluminum sulfate (alum). Indeed, in terms of turbidity abatement, 96.02% and 97.1% were obtained for Moringa and alum, respectively. However, in the case of COD abatement, the abatement rate of M. oleifera seeds was slightly higher than that of alum, 97.28% and 92.67%, respectively. Because M. oleifera is a natural resource that is locally available, an eco-friendly coagulant, non-toxic, and biodegradable and does not affect the pH of water; thus, its use allows to avoid numerous disadvantages of conventional coagulants like alum. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. [Point-of-Care Testing in Trauma Patients - Methods and Evidence].

    PubMed

    Dirkmann, Daniel; Britten, Martin W; Frey, Ulrich H

    2018-06-01

    In severely injured patients, trauma-induced coagulopathy (TIC) present at hospital admission is associated with increased transfusion requirements, morbidity and mortality. Early and effective treatment contributes to improved survival rates. Laboratory coagulation assays have long turn-around times and evidence for their usefulness, especially in the context of TIC, is weak. Due to the lack of appropriate guidance, transfusion of allogeneic blood products frequently follows a ratio-based concept (e.g., transfusion of erythrocytes and plasma in a 1 : 1 ratio). Point-of-care (PoC) tests enable the assessment of prothrombin time (PT) and activated partial thromboplastin time in few minutes. However, although normal PT in these tests allows to rule out relevant effects of several anticoagulants, they are not able to detect patients with TIC and/or requiring subsequent massive transfusion. Viscoelastic tests (VETs) make it possible to assess defects in thrombin generation, hypofibrinogenaemia, thrombocytopenia, and hyperfibrinolysis, and thus enable targeted therapy. Impairment of platelet function is the common blind spot not detectable using both standard laboratory-based tests and VETs. However, PoC platelet function tests enable to detect platelet defects and patients taking anti-platelet. Furthermore, impaired platelet function has been identified as a strong predictor for coagulopathy and massive transfusion in trauma patients. In other clinical settings, coagulation management based on VETs is associated with decreased transfusion requirements, incidence of acute kidney failure, and mortality, respectively. Data of the first small prospective randomised trial indicate superiority of VET guided coagulation management solely using coagulation factor concentrates, when compared to plasma transfusions in severe trauma. Georg Thieme Verlag KG Stuttgart · New York.

  8. Post-marketing surveillance of thrombomodulin alfa, a novel treatment of disseminated intravascular coagulation - safety and efficacy in 1,032 patients with hematologic malignancy.

    PubMed

    Asakura, Hidesaku; Takahashi, Hoyu; Tsuji, Hajime; Matsushita, Tadashi; Ninomiya, Hideyuki; Honda, Goichi; Mimuro, Jun; Eguchi, Yutaka; Kitajima, Isao; Sakata, Yoichi

    2014-03-01

    Post-marketing surveillance of thrombomodulin alfa (TM-α) was performed to evaluate safety and efficacy in patients with disseminated intravascular coagulation (DIC) with hematologic malignancy. All patients treated with TM-α from May 2008 to April 2010 in Japan were included. Information about baseline characteristics, safety, and efficacy were collected. The DIC resolution rate, survival rate on Day 28 after the last TM-α administration, and changes in DIC score and coagulation tests were evaluated. The underlying diseases associated with DIC were acute myeloid leukemia (except for acute promyelocytic leukemia, n=350), lymphoma (n=199), acute promyelocytic leukemia (n=172), acute lymphoblastic leukemia (n=156), myelodysplastic syndromes (n=61), and other (n=94). The incidence rates of bleeding-related adverse events and adverse drug reactions were 17.8% and 4.6%, respectively. In subjects with bleeding symptoms at baseline, 55.0% were assessed as disappeared or improved based on symptoms after TM-α treatment. The DIC resolution and survival rates were 55.9% and 70.7%, respectively. The DIC score and coagulation tests including thrombin-antithrombin complex (TAT) were significantly improved. Coagulation tests were significantly improved after TM-α treatment even in subjects whose clinical course of underlying disease was assessed as unchanged or exacerbated. This surveillance confirmed the safety and efficacy of TM-α in clinical practice, thus TM-α may be an ideal treatment for patients with DIC based upon hematologic malignancy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Hemostatic abnormalities in Noonan syndrome.

    PubMed

    Artoni, Andrea; Selicorni, Angelo; Passamonti, Serena M; Lecchi, Anna; Bucciarelli, Paolo; Cerutti, Marta; Cianci, Paola; Gianniello, Francesca; Martinelli, Ida

    2014-05-01

    A bleeding diathesis is a common feature of Noonan syndrome, and various coagulation abnormalities have been reported. Platelet function has never been carefully investigated. The degree of bleeding diathesis in a cohort of patients with Noonan syndrome was evaluated by a validated bleeding score and investigated with coagulation and platelet function tests. If ratios of prothrombin time and/or activated partial thromboplastin time were prolonged, the activity of clotting factors was measured. Individuals with no history of bleeding formed the control group. The study population included 39 patients and 28 controls. Bleeding score was ≥2 (ie, suggestive of a moderate bleeding diathesis) in 15 patients (38.5%) and ≥4 (ie, suggestive of a severe bleeding diathesis) in 7 (17.9%). Abnormal coagulation and/or platelet function tests were found in 14 patients with bleeding score ≥2 (93.3%) but also in 21 (87.5%) of those with bleeding score <2. The prothrombin time and activated partial thromboplastin time were prolonged in 18 patients (46%) and partial deficiency of factor VII, alone or in combination with the deficiency of other vitamin K-dependent factors, was the most frequent coagulation abnormality. Moreover, platelet aggregation and secretion were reduced in 29 of 35 patients (82.9%, P < .01 for all aggregating agents). Nearly 40% of patients with the Noonan syndrome had a bleeding diathesis and >90% of them had platelet function and/or coagulation abnormalities. Results of these tests should be taken into account in the management of bleeding or invasive procedures in these patients. Copyright © 2014 by the American Academy of Pediatrics.

  10. Dielectric coagulometry: a new approach to estimate venous thrombosis risk.

    PubMed

    Hayashi, Yoshihito; Katsumoto, Yoichi; Omori, Shinji; Yasuda, Akio; Asami, Koji; Kaibara, Makoto; Uchimura, Isao

    2010-12-01

    We present dielectric coagulometry as a new technique to estimate the risk of venous thrombosis by measuring the permittivity change associated with the blood coagulation process. The method was first tested for a simple system of animal erythrocytes suspended in fibrinogen solution, where the coagulation rate was controlled by changing the amount of thrombin added to the suspension. Second, the method was applied to a more realistic system of human whole blood, and the inherent coagulation process was monitored without artificial acceleration by a coagulation initiator. The time dependence of the permittivity at a frequency around 1 MHz showed a distinct peak at a time that corresponds to the clotting time. Our theoretical modeling revealed that the evolution of heterogeneity and the sedimentation in the system cause the peak of the permittivity.

  11. Optimization of composite coagulant made from polyferric chloride and tapioca starch in landfill leachate treatment

    NASA Astrophysics Data System (ADS)

    Shaylinda, M. Z. N.; Hamidi, A. A.; Mohd, N. A.; Ariffin, A.; Irvan, D.; Hazreek, Z. A. M.; Nizam, Z. M.

    2018-04-01

    In this research, the performance of polyferric chloride and tapioca flour as composite coagulants for partially stabilized leachate was investigated. Response surface methodology (RSM) was used to optimize the coagulation and flocculation process of partially stabilized leachate. Central composite design a standard design tool in RSM was applied to evaluate the interactions and effects of dose and pH. Dose 0.2 g/L Fe and pH 4.71 were the optimum value suggested by RSM. Experimental test based on the optimum condition, resulted in 95.9%, 94.6% and 50.4% of SS, color and COD removals, respectively. The percentage difference recorded between experimental and model responses was <5%. Therefore, it can be concluded that RSM was an appropriate optimization tool for coagulation and flocculation process.

  12. Coagulant from Leucaena leucocephala for Chromium Removal

    NASA Astrophysics Data System (ADS)

    Razak, N. H. Abd; Khairuddin, N.; Ismail, K. N.; Musa, M.

    2018-05-01

    This research investigated the effectiveness of leucaena leucocephala as a natural coagulant for chromium removal. Leucaena leucocephala is a permanent non-climbing shrub tree which is wild and abundant in Malaysia and commonly known as petai belalang. Coagulation experiment using jar test were performed where the effect of coagulant dosage and pH were examined. The parameters investigated were suspended solid (SS), chemical oxygen demand (COD), biological oxygen demand (BOD), turbidity and chromium content. The optimum of leucaena leucocephala coagulant dosage for removal of suspended solid, turbidity, COD, BOD and Chromium is at range 400-600 mg/L which yielded 45, 31.4, 38.5, 27.5 and 4.05% removal respectively. While the optimum pH is at pH 2-4 (acidic) which give 33.3, 26.8, 33.75, 31.4 and 14.06% removal of suspended solid, COD, BOD, turbidity and chromium content respectively. It is concluded that the leucaena leucocephala showed tremendous potential for chromium removal.

  13. The application of bioflocculant for the removal of humic acids from stabilized landfill leachates.

    PubMed

    Zouboulis, Anastasios I; Chai, Xiao-Li; Katsoyiannis, Ioannis A

    2004-01-01

    The evaluation of bioflocculant, in comparison with traditional inorganic coagulants, for the removal of humic acids from landfill leachates stabilized by biological treatment, was performed using conventional jar-test coagulation experiments. The optimized conditions (pH and coagulant dosage) were identified for the treatment of synthetic solutions as well as for biologically pre-treated landfill leachates. It was found that the application of bioflocculant was quite efficient in the removal of humic acids from synthetic solutions as well as in the reduction of COD content from real landfill leachates. The optimal pH value was found to be between 7 and 7.5, while a 20 mg/l bioflocculant dosage was sufficient in providing more than 85% humic acid removal. The results were comparable with those obtained by the application of conventional coagulants such as alum or polyaluminum chloride; therefore, bioflocculant can be considered as a viable alternative in the treatment of landfill leachates applying coagulation.

  14. Mid-infrared spectroscopy predictions as indicator traits in breeding programs for enhanced coagulation properties of milk.

    PubMed

    Cecchinato, A; De Marchi, M; Gallo, L; Bittante, G; Carnier, P

    2009-10-01

    The aims of this study were to investigate variation of milk coagulation property (MCP) measures and their predictions obtained by mid-infrared spectroscopy (MIR), to investigate the genetic relationship between measures of MCP and MIR predictions, and to estimate the expected response from a breeding program focusing on the enhancement of MCP using MIR predictions as indicator traits. Individual milk samples were collected from 1,200 Brown Swiss cows (progeny of 50 artificial insemination sires) reared in 30 herds located in northern Italy. Rennet coagulation time (RCT, min) and curd firmness (a(30), mm) were measured using a computerized renneting meter. The MIR data were recorded over the spectral range of 4,000 to 900 cm(-1). Prediction models for RCT and a(30) based on MIR spectra were developed using partial least squares regression. A cross-validation procedure was carried out. The procedure involved the partition of available data into 2 subsets: a calibration subset and a test subset. The calibration subset was used to develop a calibration equation able to predict individual MCP phenotypes using MIR spectra. The test subset was used to validate the calibration equation and to estimate heritabilities and genetic correlations for measured MCP and their predictions obtained from MIR spectra and the calibration equation. Point estimates of heritability ranged from 0.30 to 0.34 and from 0.22 to 0.24 for RCT and a(30), respectively. Heritability estimates for MCP predictions were larger than those obtained for measured MCP. Estimated genetic correlations between measures and predictions of RCT were very high and ranged from 0.91 to 0.96. Estimates of the genetic correlation between measures and predictions of a(30) were large and ranged from 0.71 to 0.87. Predictions of MCP provided by MIR techniques can be proposed as indicator traits for the genetic enhancement of MCP. The expected response of RCT and a(30) ensured by the selection using MIR predictions as indicator traits was equal to or slightly less than the response achievable through a single measurement of these traits. Breeding strategies for the enhancement of MCP based on MIR predictions as indicator traits could be easily and immediately implemented for dairy cattle populations where routine acquisition of spectra from individual milk samples is already performed.

  15. Influence of micellar calcium and phosphorus on rennet coagulation properties of cows milk.

    PubMed

    Malacarne, Massimo; Franceschi, Piero; Formaggioni, Paolo; Sandri, Sandro; Mariani, Primo; Summer, Andrea

    2014-05-01

    The main requirement for milk processed in most cheese typologies is its rennet coagulation ability. Despite the increasing number of studies, the causes for abnormal coagulation of milk are not fully understood. The aim of this study was to ascertain relationships between milk characteristics and its rennet coagulation ability, focusing on the influence of calcium (Ca) and phosphorus (P). Ca and P are essential constituents of the micelles. Micellar P can be present as part of colloidal calcium phosphate (inorganic-P) or covalently bound to caseins as phosphate groups (casein-P). Eighty one herd milk samples (SCC<400 000 cell/ml) were classified as Optimal (8), Suboptimal (39) Poor (29) and Non-coagulating milk (5), according to their rennet coagulation parameters as assessed by lactodynamographic test. Samples were analysed for their chemical composition (basic composition, protein fractions, minerals and salt equilibria), physicochemical parameters (pH and titratable acidity) and rheological properties. Optimal milk was characterised by the highest contents of major constituents, protein fractions and minerals, lowest content of chloride and highest values of titratable acidity. Non-coagulating milk was characterised by the highest values of pH and the lowest of titratable acidity. At micellar level, Optimal milk showed the highest values of colloidal Ca, casein-P and colloidal Mg (g/100 g casein), while Non-coagulating milk showed the lowest values. Interestingly, there was no statistical difference regarding the content of colloidal inorganic-P (g/100 g casein) between Optimal and Non-coagulating milks. Overall, high mineralisation of the micelle (expressed as g inorganic-P/100 g casein) positively affect its rennetability. However, excessive mineralisation could lead to a reduction of the phosphate groups (g casein-P/100 g casein) available for curd formation.

  16. Coagulation parameters in copperhead compared to other Crotalinae envenomation: secondary analysis of the F(ab')2 versus Fab antivenom trial.

    PubMed

    Gerardo, Charles J; Vissoci, Joao R Nickenig; Brown, Michael W J; Bush, Sean P

    2017-02-01

    Coagulation derangements in copperhead envenomation are considered less severe than other crotaline envenomations, resulting in recommendations to limit both coagulation testing and antivenom treatment. A prospective, blinded, multicenter, randomized clinical trial comparing the effectiveness of F(ab') 2 versus Fab antivenom in crotaline envenomation patients was completed in 2011. We determined the difference between coagulation parameters in copperhead compared to other crotaline envenomations. We performed a post hoc analysis comparing the coagulation parameters (platelets and fibrinogen) prospectively obtained in the aforementioned trial. All the patients received antivenom in one of three treatment arms [F(ab') 2 with maintenance, F(ab') 2 with placebo maintenance, or Fab with maintenance]. Coagulation parameters were measured at pretreatment baseline, during acute hospitalization, day 5, day 8, and day 15 post-envenomation. Mean platelet count and fibrinogen levels for the copperhead and other crotaline groups were compared. The platelet and fibrinogen point estimates with distribution are presented graphically over time. 122 patients were enrolled in the study. There were 22 patients with copperhead envenomation, 93 with other crotaline envenomations, and 7 that could not be definitively determined. The mean age was 42 (SD 20) years. There was a minor pretreatment difference in mean baseline platelet count between the copperhead group (246 × 109/L 95% CI 215, 277) compared to other crotaline envenomation patients (184 × 109/L 95% CI 167, 202). There was a modest pretreatment difference in mean fibrinogen level between copperhead patients (345 mg/dL 95% CI 277, 415) and other crotaline patients (261mg/dL 95% CI 241, 281). Pretreatment coagulation parameter means were normal and converged post treatment. On average, copperhead envenomations have less severe initial coagulation derangements. However, in mild envenomations, differences in laboratory values are minimal and there is substantial variation in individual patients regardless of species. Species alone should not be used to determine the need for laboratory testing or treatment in crotaline snakebite.

  17. Evaluation of Optical Coherence Tomography for the Measurement of the Effects of Activators and Anticoagulants on the Blood Coagulation In Vitro

    PubMed Central

    Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-01-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d1/e) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening. PMID:23392340

  18. Evaluation of optical coherence tomography for the measurement of the effects of activators and anticoagulants on the blood coagulation in vitro.

    PubMed

    Xu, Xiangqun; Geng, Jinhai; Liu, Gangjun; Chen, Zhongping

    2013-08-01

    Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d(1/e)) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening.

  19. Alterations in Blood Coagulation and Viscosity Among Young Male Cigarette Smokers of Al-Jouf Region in Saudi Arabia.

    PubMed

    Almarshad, Hassan A; Hassan, Fathelrahman M

    2016-05-01

    Hemorheology, a measure of rheological properties of blood, is often correlated with cerebral blood flow and cardiac output; an increased blood viscosity may increase the risk of thrombosis or thromboembolic events. Previous studies have reported a large variation in hemorheological properties of blood among smokers. This prompted us to conduct coagulation experiments to evaluate the effect of cigarette smoking on hematological parameters, like cell counts, and coagulation parameters among young males in Al-Jouf region, Saudi Arabia. The hematological and coagulation parameters were used to relate the changes in viscosity and coagulation to smoking. A total of 321 male participants (126 nonsmokers and 195 smokers) were enrolled into the study as randomized sample. Complete blood count was measured by hematology analyzer, and coagulation tests were performed by coagulation analyzer. Thettest analysis was performed to compare the relationships of variables between the 2 groups. The results confirmed that smoking alters some hematology parameters leading to significant deterioration in blood flow properties. Smoking also increased the hematocrit (HCT), whole blood viscosity (WBV), and plasma viscosity (PV) but decreased the international normalized ratio (INR). The decrease in INR was found to be associated with the increase in WBV, PV, and HCT. Further investigations are necessary to assess the reversibility of such changes in cessation of smoking or other elements of influence. © The Author(s) 2014.

  20. IgMk paraprotein from gammopathy patient can bind to cardiolipin and interfere with coagulation assay: a case report.

    PubMed

    Wu, Xin-Yao; Yin, Yu-Feng; Teng, Jia-Lin; Zhang, Li-Wei; Yang, Cheng-de

    2017-06-23

    The monoclonal gammopathies are a group of plasma-cell proliferative disorders characterized by the secretion of monoclonal immunoglobulin (M protein or paraprotein). Some rare cases have revealed the specific affinity of paraprotein as autoantibody. Here we report a patient with monoclonal gammopathy of undetermined significance (MGUS) accompanied by a remarkable increase of anticardiolipin antibody (aCL) and an extensively decreased coagulation factor activity, however, without any clinical signs of antiphospholipid syndrome (APS) and bleeding. Our further investigation indicated that IgMκ paraprotein of this patient possessed an antibody activity against phospholipids so as to bind to cardiolipin and interfere with coagulation assay in vitro. This case might be indicative that an abnormality of coagulation tests, disturbed by IgMκ paraprotein, does not predict a risk of bleeding in this patient.

  1. Efficacy of intraoperative cell salvage in decreasing perioperative blood transfusion rates in first-time cardiac surgery patients: a retrospective study.

    PubMed

    Côté, Claudia L; Yip, Alexandra M; MacLeod, Jeffrey B; O'Reilly, Bill; Murray, Joshua; Ouzounian, Maral; Brown, Craig D; Forgie, Rand; Pelletier, Marc P; Hassan, Ansar

    2016-09-01

    Evidence regarding the safety and efficacy of intraoperative cell salvage (ICS) in transfusion reduction during cardiac surgery remains conflicting. We sought to evaluate the impact of routine ICS on outcomes following cardiac surgery. We conducted a retrospective analysis of patients who underwent nonemergent, first-time cardiac surgery 18 months before and 18 months after the implementation of routine ICS. Perioperative transfusion rates, postoperative bleeding, clinical and hematological outcomes, and overall cost were examined. We used multivariable logistic regression modelling to determine the risk-adjusted effect of ICS on likelihood of perioperative transfusion. A total of 389 patients formed the final study population (186 undergoing ICS and 203 controls). Patients undergoing ICS had significantly lower perioperative transfusion rates of packed red blood cells (pRBCs; 33.9% v. 45.3% p = 0.021), coagulation products (16.7% v. 32.5% p < 0.001) and any blood product (38.2% v. 52.7%, p = 0.004). Patients receiving ICS had decreased mediastinal drainage at 12 h (mean 320 [range 230-550] mL v. mean 400 [range 260-690] mL, p = 0.011) and increased postoperative hemoglobin (mean 104.7 ± 13.2 g/L v. 95.0 ± 11.9 g/L, p < 0.001). Following adjustment for other baseline and intraoperative covariates, ICS emerged as an independent predictor of lower perioperative transfusion rates of pRBCs (odds ratio [OR] 0.52, 95% confidence interval [CI] 0.31-0.87), coagulation products (OR 0.41, 95% CI 0.24-0.71) and any blood product (OR 0.47, 95% CI 0.29-0.77). Additionally, ICS was associated with a cost benefit of $116 per patient. Intraoperative cell salvage could represent a clinically cost-effective way of reducing transfusion rates in patients undergoing cardiac surgery. Further research on systematic ICS is required before recommending it for routine use.

  2. Versatility of erbium YAG laser: from fractional skin rejuvenation to full-field skin resurfacing.

    PubMed

    Holcomb, J David

    2011-05-01

    For the laser surgeon, the Er-YAG laser is an invaluable tool that delivers unsurpassed ablation efficiency, and with appropriate functionality (quasi long-pulse feature) provides sufficient tissue coagulation to remodel deep rhytids. As such, the 2940-nm wavelength is well suited for routine laser skin rejuvenation in full-field, fractional, and point-beam modes with additional benefits, including applicability to diverse skin types, short healing times, and a low likelihood of energy-related complications. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Age dependency for coagulation parameters in paediatric populations. Results of a multicentre study aimed at defining the age-specific reference ranges.

    PubMed

    Toulon, Pierre; Berruyer, Micheline; Brionne-François, Marie; Grand, François; Lasne, Dominique; Telion, Caroline; Arcizet, Julien; Giacomello, Roberta; De Pooter, Neila

    2016-07-04

    Understanding of developmental haemostasis is critical to ensure optimal prevention, diagnosis, and treatment of haemorrhagic and thrombotic diseases in children. As coagulation test results are known to be dependent on the reagents/analysers used, it is recommended for each laboratory to define the age-dependent reference ranges by using its own technical condition. That study was carried out in seven centers to establish age-specific reference ranges using the same reagents and analyser. Plasma samples were obtained from 1437 paediatric patients from the following age groups: 15 days-4 weeks (n=36), 1-5 months (n=320), 6-12 months (n=176), 1-5 years (n=507), 6-10 years (n=132) and 11-17 years (n=262). Indication of coagulation testing was pre-operative screening for non-acute diseases in most cases. PT values were similar in the different age groups to those in adults, whereas longer aPTTs were demonstrated in the younger children. Plasma levels of all clotting factors, except for FV, were significantly decreased (p<0.0001) in the youngest children, adult values being usually reached before the end of the first year. The same applied to antithrombin, protein C/S, and plasminogen. In contrast, FVIII and VWF levels were elevated in the youngest children and returned to adult values within six months. The same applied to D-dimer levels, which were found elevated, particularly until six months of life, until puberty. These data suggest that most coagulation test results are highly dependent on age, mainly during the first year of life, and that age-specific reference ranges must be used to ensure proper evaluation of coagulation in children.

  4. Sonoclot evaluation of whole blood coagulation in healthy adult dogs.

    PubMed

    Babski, Danielle M; Brainard, Benjamin M; Krimer, Paula M; Ralph, Alan G; Pittman, Jennifer R; Koenig, Amie

    2012-12-01

    To establish a standard protocol for analysis of canine whole blood and generate reference intervals for healthy dogs using the Sonoclot analyzer, and to compare Sonoclot values to standard and viscoelastic coagulation tests. Prospective study. Veterinary University research facility and teaching hospital. Twelve healthy random source dogs and 52 healthy dogs from the general veterinary school population. Blood sampling for viscoelastic coagulation testing. Blood was collected from 12 healthy adult dogs by jugular venipuncture. After a rest period at room temperature of 30, 60, or 120 minutes, 340 μL of citrated blood was added to 20 μL of 0.2 M CaCl(2) in 1 of 2 cuvette types warmed to 37° C. Cuvettes contained a magnetic stir-bar with glass beads (gbACT+) or only a magnetic stir-bar (nonACT). Reference interval samples were collected from 52 healthy adult dogs and analyzed in duplicate. The ACT, CR, and PF were not affected by duration of rest period for either cuvette type. ACT variability was decreased when using gbACT+ cuvettes (P < 0.05). In normal dogs reference intervals (mean ± 2 SD) using gbACT+ cuvettes were: ACT 56.0-154.0 seconds, CR 14.85-46.0, and PF 2.1-4.05. ACT correlated to TEG R-time, K-time, and angle, while CR correlated with all TEG parameters. Fibrinogen correlated with ACT, CR, and PF. Sonoclot did not correlate with other common coagulation tests. Sonoclot provides viscoelastic evaluation of canine whole blood coagulation and correlated to several TEG parameters and fibrinogen. A standard protocol and reference intervals were established. © Veterinary Emergency and Critical Care Society 2012.

  5. Technical note: Improving modeling of coagulation, curd firming, and syneresis of sheep milk.

    PubMed

    Cipolat-Gotet, Claudio; Pazzola, Michele; Ferragina, Alessandro; Cecchinato, Alessio; Dettori, Maria L; Vacca, Giuseppe M

    2018-04-18

    The importance of milk coagulation properties for milk processing, cheese yield, and quality is widely recognized. The use of traditional coagulation traits presents several limitations for testing bovine milk and even more for sheep milk, due to its rapid coagulation and curd firming, and early syneresis of coagulum. The aim of this technical note is to test and improve model fitting for assessing coagulation, curd firming, and syneresis of sheep milk. Using milk samples from 87 Sarda ewes, we performed in duplicate lactodynamographic testing. On each of the 174 analyzed milk aliquots, using 180 observations from each aliquot (one every 15 s for 45 min after rennet addition), we compared 4 different curd firming models as a function of time (CF t , mm) using a nonlinear procedure. The most accurate and informative results were observed using a modified 4-parameter model, structured as follows: [Formula: see text] , where t is time, RCT eq (min) is the gelation time, CF P (mm) is the potential asymptotical CF at an infinite time, k CF (%/min) is the curd firming rate constant, and k SR (%/min) is the curd syneresis rate constant. To avoid nonconvergence and computational problems due to interrelations among the equation parameters, CF P was preliminarily defined as a function of maximum observed curd firmness (CF max , mm) recorded during the analysis. For this model, all the modeling equations of individual sheep milk aliquots were converging, with a negligible standard error of the estimates (coefficient of determination >0.99 for all individual sample equations). Repeatability of the modeled parameters was acceptable, also in the presence of curd syneresis during the lactodynamographic analysis. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  6. Treatment and toxicity reduction of textile dyeing wastewater using the electrocoagulation-electroflotation process.

    PubMed

    Kim, Han-Lae; Cho, Jong-Bok; Park, Yong-Jin; Cho, Il-Hyoung

    2016-07-02

    A pilot-scale study was conducted using the electrocoagulation-electroflotation (EC-EF) process to treat textile dyeing raw wastewater to evaluate treatment performance. The effects of some key factors, such as current density, hydraulic retention time (HRT), and removal of conductivity, total suspended solids (TSS), chemical oxygen demand (COD), and color were investigated. The operating variables were current density of 0-300 A m(-2), HRT of 0-30 min, and a coagulant (anionic polyacrylamide (A-PAM)) dosage of 0-30 mg L(-1). Daphnia magna was used to test acute toxicity in raw and treated wastewater. Under the operating conditions without added coagulant, maxima of 51%, 88%, 84%, and 99% of conductivity, TSS, COD, and color were removed, respectively, with a HRT of 30 min. The coagulant enhanced removal of all wastewater parameters. Removal maxima of 59%, 92%, 94%, and 98% for conductivity, TSS, COD, and color were observed, respectively, with an optimal dosage of 30 mg L(-1) and a shortened HRT of 20 min. The 48 h-LC50 D. magna test showed that the raw wastewater was highly toxic. However, the EC-EF process decreased toxicity of the treated samples significantly, and >70% toxicity reduction was achieved by the EC-EF process with the addition of 15-30 mg L(-1) coagulant, HRT of 20 min, and current density of 150-300 A m(-2). The pilot scale test (0.3 m(3 )h(-1)) shows that the EC-EF process with added coagulant effectively treated textile dyeing wastewater.

  7. PubMed Central

    Baillargeon, L.; Drouin, J.; Desjardins, L.; Leroux, D.; Audet, D.

    1993-01-01

    The purpose of this study, which took the form of a two-period cross-over clinical trial, was to determine whether a homeopathic substance, Arnica Montana, significantly decreased bleeding time (Simplate II) and to describe its impact on various blood coagulation tests. It was not shown that this substance had a significant impact on various parameters of blood coagulation in healthy volunteers in the period immediately following administration [corrected]. PMID:7903572

  8. Systemic and Microvascular Effects of Resuscitation with Blood Products After Severe Hemorrhage in Rats

    DTIC Science & Technology

    2014-01-01

    thickness, blood flow, and microvascular permeability were studied using intravital microscopy. Hemodynamics and coagulation tests (rotational...Microcirculation; packed red blood cells; intravital microscopy; ROTEM; plasma proteins; rats. Current US military guidance for the resuscitation of warfighters...was used for coagulation assays (rotational thromboelast- ometry [ROTEM], TEM Innovations GmbH, Germany). Intravital Microscopy and Animal Preparation

  9. The Effects of the Contact Activation System on Hemorrhage

    PubMed Central

    Simão, Fabrício; Feener, Edward P.

    2017-01-01

    The contact activation system (CAS) exerts effects on coagulation via multiple mechanisms, which modulate both the intrinsic and extrinsic coagulation cascades as well as fibrinolysis and platelet activation. While the effects of the CAS on blood coagulation measured as activated partial thromboplastin time shortening are well documented, genetic mutations that result in deficiencies in the expression of either plasma prekallikrein (PPK) or factor XII (FXII) are not associated with spontaneous bleeding or increased bleeding risk during surgery. Deficiencies in these proteins are often undiagnosed for decades and detected later in life during routine coagulation assays without an apparent clinical phenotype. Increased interest in the CAS as a potentially safe target for antithrombotic therapies has emerged, in large part, from studies on animal models with provoked thrombosis, which have shown that deficiencies in PPK or FXII can reduce thrombus formation without increasing bleeding. Gene targeting and pharmacological studies in healthy animals have confirmed that PPK and FXII blockade does not cause coagulopathies. These findings support the conclusion that CAS is not required for hemostasis. However, while deficiencies in FXII and PPK do not significantly affect bleeding associated with peripheral wounds, recent reports have demonstrated that these proteins can promote hemorrhage in the retina and brain. Intravitreal injection of plasma kallikrein (PKal) induces retinal hemorrhage and intracerebral injection of PKal increases intracranial bleeding. PPK deficiency and PKal inhibition ameliorates hematoma formation following cerebrovascular injury in diabetic animals. Moreover, both PPK and FXII deficiency are protective against intracerebral hemorrhage caused by tissue plasminogen activator-mediated thrombolytic therapy in mice with thrombotic middle cerebral artery occlusion. Thus, while the CAS is not required for hemostasis, its inhibition may provide an opportunity to reduce hemorrhage in the retina and brain. Characterization of the mechanisms and potential clinical implications associated with the effects of the CAS on hemorrhage requires further consideration of the effects of PPK and FXII on hemorrhage beyond their putative effects on coagulation cascades. Here, we review the experimental and clinical evidence on the effects of the CAS on bleeding and hemostatic mechanisms. PMID:28824910

  10. Epsilon aminocaproic acid reduces blood transfusion and improves the coagulation test after pediatric open-heart surgery: a meta-analysis of 5 clinical trials.

    PubMed

    Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan

    2015-01-01

    Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P < 0.0001), and platelet concentrate (MD: -10.66; 95% CI: -18.45 to -2.87; P = 0.007), and had a lower re-exploration rate (RR: 0.46; 95% CI: 0.23 to 0.92; P = 0.03). Prophylactic EACA also improved coagulation tests 6 hours after open-heart surgery. Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the prevention of postoperative blood transfusion following pediatric cardiac surgery.

  11. Perplexing purpura in two females: Rare case of autoerythrocyte sensitization syndrome

    PubMed Central

    Tainwala, Ram R.; Phiske, Meghna; Raghuwanshi, Abhijith; Mathapati, Sukesh; Manjare, Ashwini K.; Jerajani, Hemangi R.

    2013-01-01

    Autoerythrocyte sensitization syndrome is a psychologically induced painful bruising condition. Two female, 19 and 30-year-old presented with recurrent episodes of painful ecchymotic bruising over accessible areas of body. In the younger female, episodes were since 3 years and were precipitated by stress and trivial trauma. The elder female presented with similar lesions since 3 months which were spontaneous in presentation. There were no obvious psychiatric manifestations in either. Clinically, ecchymotic changes in various stages of development were seen. Routine hemogram and coagulation profile were normal. Histopathology showed extravasated erythrocytes, perivascular neutrophils and fibrinoid deposition. Intradermal injection of autologous whole blood produced a painful ecchymotic reaction after 2 h similar to the presenting lesions. Psychiatric evaluation revealed mild mixed depression – anxiety disorder in the younger female while the latter revealed no abnormalities. The diagnosis of autoerythrocyte sensitization syndrome was made based on clinical history and findings, positive autoerythrocyte sensitization test, psychiatric evaluation and absence of any other clinical or laboratory pathology. PMID:24350012

  12. Thromboelastometry

    PubMed Central

    Dumitrescu, Gabriel; Januszkiewicz, Anna; Ågren, Anna; Magnusson, Maria; Wahlin, Staffan; Wernerman, Jan

    2017-01-01

    Abstract The severity of liver disease is assessed by scoring systems, which include the conventional coagulation test prothrombin time-the international normalized ratio (PT-INR). However, PT-INR is not predictive of bleeding in liver disease and thromboelastometry (ROTEM) has been suggested to give a better overview of the coagulation system in these patients. It has now been suggested that coagulation as reflected by tromboelastomety may also be used for prognostic purposes. The objective of our study was to investigate whether thrombelastometry may discriminate the degree of liver insufficiency according to the scoring systems Child Pugh and Model for End-stage Liver Disease (MELD). Forty patients with chronic liver disease of different etiologies and stages were included in this observational cross-sectional study. The severity of liver disease was evaluated using the Child-Pugh score and the MELD score, and blood samples for biochemistry, conventional coagulation tests, and ROTEM were collected at the time of the final assessment for liver transplantation. Statistical comparisons for the studied parameters with scores of severity were made using Spearman correlation test and receiver-operating characteristic (ROC) curves. Spearman correlation coefficients indicated that the thromboelastometric parameters did not correlate with Child-Pugh or MELD scores. The ROC curves of the thromboelastometric parameters could not differentiate advanced stages from early stages of liver cirrhosis. Standard ROTEM cannot discriminate the stage of chronic liver disease in patients with severe chronic liver disease. PMID:28591054

  13. Prognostic significance of blood coagulation tests in carcinoma of the lung and colon.

    PubMed

    Wojtukiewicz, M Z; Zacharski, L R; Moritz, T E; Hur, K; Edwards, R L; Rickles, F R

    1992-08-01

    Blood coagulation test results were collected prospectively in patients with previously untreated, advanced lung or colon cancer who entered into a clinical trial. In patients with colon cancer, reduced survival was associated (in univariate analysis) with higher values obtained at entry to the study for fibrinogen, fibrin(ogen) split products, antiplasmin, and fibrinopeptide A and accelerated euglobulin lysis times. In patients with non-small cell lung cancer, reduced survival was associated (in univariate analysis) with higher fibrinogen and fibrin(ogen) split products, platelet counts and activated partial thromboplastin times. In patients with small cell carcinoma of the lung, only higher activated partial thromboplastin times were associated (in univariate analysis) with reduced survival in patients with disseminated disease. In multivariate analysis, higher activated partial thromboplastin times were a significant independent predictor of survival for patients with non-small cell lung cancer limited to one hemithorax and with disseminated small cell carcinoma of the lung. Fibrin(ogen) split product levels were an independent predictor of survival for patients with disseminated non-small cell lung cancer as were both the fibrinogen and fibrinopeptide A levels for patients with disseminated colon cancer. These results suggest that certain tests of blood coagulation may be indicative of prognosis in lung and colon cancer. The heterogeneity of these results suggests that the mechanism(s), intensity, and pathophysiological significance of coagulation activation in cancer may differ between tumour types.

  14. Red blood cells aggregability measurement of coagulating blood in extracorporeal circulation system with multiple-frequency electrical impedance spectroscopy.

    PubMed

    Li, Jianping; Sapkota, Achyut; Kikuchi, Daisuke; Sakota, Daisuke; Maruyama, Osamu; Takei, Masahiro

    2018-07-30

    Red blood cells (RBCs) aggregability A G of coagulating blood in extracorporeal circulation system has been investigated under the condition of pulsatile flow. Relaxation frequency f c from the multiple-frequency electrical impedance spectroscopy is utilized to obtain RBCs aggregability A G . Compared with other methods, the proposed multiple-frequency electrical impedance method is much easier to obtain non-invasive measurement with high speed and good penetrability performance in biology tissues. Experimental results show that, RBCs aggregability A G in coagulating blood falls down with the thrombus formation while that in non-coagulation blood almost keeps the same value, which has a great agreement with the activated clotting time (ACT) fibrinogen concertation (F bg ) tests. Modified Hanai formula is proposed to quantitatively analyze the influence of RBCs aggregation on multiple-frequency electrical impedance measurement. The reduction of RBCs aggregability A G is associated with blood coagulation reaction, which indicates the feasibility of the high speed, compact and cheap on-line thrombus measurement biosensors in extracorporeal circulation systems. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Optimization of coagulation-flocculation treatment on paper-recycling wastewater: Application of response surface methodology.

    PubMed

    Birjandi, Noushin; Younesi, Habibollah; Bahramifar, Nader; Ghafari, Shahin; Zinatizadeh, Ali Akbar; Sethupathi, Sumathi

    2013-01-01

    The application of coagulation-flocculation (CF) process for treating the paper-recycling wastewater in jar-test experiment was employed. The purpose of the study was aimed to examine the efficiency of alum and poly aluminum chloride (PACl) in combination with a cationic polyacrylamide (C-PAM) in removal of chemical oxygen demand (COD) and turbidity from paper-recycling wastewater. Optimization of CF process were performed by varying independent parameters (coagulants dosage, flocculants dosage, initial COD and pH) using a central composite design (CCD) under response surface methodology (RSM). Maximum set required 4.5 as pH, 40 mg/L coagulants dosage and 4.5 mg/L flocculants dosage at which gave 92% reduction of turbidity, 97% of COD removal and SVI 80 mL/g. The best coagulant and flocculants were alum and chemfloc 3876 at dose of 41 and 7.52 mg/L, respectively, correspondingly at pH of 6.85. These conditions gave 91.30% COD and 95.82% turbidity removals and 12 mL/g SVI.

  16. An ecoimmunological approach to study evolutionary and ancient links between coagulation, complement and Innate immunity

    PubMed Central

    Kasetty, Gopinath; Alyafei, Saud; Smeds, Emanuel; Salo-Ahen, Outi M. H.; Hansson, Stefan R.; Egesten, Arne; Herwald, Heiko

    2018-01-01

    ABSTRACT Coagulation, complement, and innate immunity are tightly interwoven and form an alliance that can be traced back to early eukaryotic evolution. Here we employed an ecoimmunological approach using Tissue Factor Pathway Inhibitor (TFPI)-1-derived peptides from the different classes of vertebrates (i.e. fish, reptile, bird, and mammals) and tested whether they can boost killing of various human bacterial pathogens in plasma. We found signs of species-specific conservation and diversification during evolution in these peptides that significantly impact their antibacterial activity. Though all peptides tested executed bactericidal activity in mammalian plasma (with the exception of rodents), no killing was observed in plasma from birds, reptiles, and fish, pointing to a crucial role for the classical pathway of the complement system. We also observed an interference of these peptides with the human intrinsic pathway of coagulation though, unlike complement activation, this mechanism appears not to be evolutionary conserved. PMID:29473457

  17. Effect of Immobilized Antithrombin III on the Thromboresistance of Polycarbonate Urethane.

    PubMed

    Lukas, Karin; Stadtherr, Karin; Gessner, Andre; Wehner, Daniel; Schmid, Thomas; Wendel, Hans Peter; Schmid, Christof; Lehle, Karla

    2017-03-24

    The surface of foils and vascular grafts made from a thermoplastic polycarbonate urethanes (PCU) (Chronoflex AR) were chemically modified using gas plasma treatment, binding of hydrogels-(1) polyethylene glycol bisdiamine and carboxymethyl dextran (PEG-DEX) and (2) polyethyleneimine (PEI)-and immobilization of human antithrombin III (AT). Their biological impact was tested in vitro under static and dynamic conditions. Static test methods showed a significantly reduced adhesion of endothelial cells, platelets, and bacteria, compared to untreated PCU. Modified PCU grafts were circulated in a Chandler-Loop model for 90 min at 37 °C with human blood. Before and after circulation, parameters of the hemostatic system (coagulation, platelets, complement, and leukocyte activation) were analyzed. PEI-AT significantly inhibited the activation of both coagulation and platelets and prevented the activation of leukocytes and complement. In conclusion, both modifications significantly reduce coagulation activation, but only PEI-AT creates anti-bacterial and anti-thrombogenic functionality.

  18. Effect of fibrinogen on blood coagulation detected by optical coherence tomography.

    PubMed

    Xu, Xiangqun; Teng, Xiangshuai

    2015-05-21

    Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d1/e) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0-8 g L(-1)); and 2) native plasma with commercial Fbg added (0-8 g L(-1)). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels.

  19. Selection of the surface water treatment technology - a full-scale technological investigation.

    PubMed

    Pruss, Alina

    2015-01-01

    A technological investigation was carried out over a period of 2 years to evaluate surface water treatment technology. The study was performed in Poland, in three stages. From November 2011 to July 2012, for the first stage, flow tests with a capacity of 0.1-1.5 m³/h were performed simultaneously in three types of technical installations differing by coagulation modules. The outcome of the first stage was the choice of the technology for further investigation. The second stage was performed between September 2012 and March 2013 on a full-scale water treatment plant. Three large technical installations, operated in parallel, were analysed: coagulation with sludge flotation, micro-sand ballasted coagulation with sedimentation, coagulation with sedimentation and sludge recirculation. The capacity of the installations ranged from 10 to 40 m³/h. The third stage was also performed in a full-scale water treatment plant and was aimed at optimising the selected technology. This article presents the results of the second stage of the full-scale investigation. The critical treatment process, for the analysed water, was the coagulation in an acidic environment (6.5 < pH < 7.0) carried out in a system with rapid mixing, a flocculation chamber, preliminary separation of coagulation products, and removal of residual suspended solids through filtration.

  20. A survey of coagulation laboratory practices and satisfaction ratings of member laboratories of the Thailand National External Quality Assessment Scheme for blood coagulation.

    PubMed

    Chuntarut, A; Tientadakul, P; Wongkrajang, P

    2016-06-01

    The Thailand National External Quality Assessment Scheme (NEQAS) for blood coagulation was established in 2005. The objective of this study was to collect data of coagulation laboratory practices and satisfaction of NEQAS member. Two hundred seventy-six questionnaires were sent to laboratories that are members of NEQAS to obtain data relating to coagulation laboratory practice and satisfaction in 2014. Data from this survey were compared with data from the survey conducted in 2005 to evaluate levels of improvement. Of 276 questionnaires sent, 212 (76.8%) were returned. Improvements were characterized by the number of laboratories that (i) decreased use of 3.8% sodium citrate as anticoagulant; (ii) implemented use of at least two control levels for internal quality control; and (iii) implemented reporting of reference values with results, as well as establishing their own reference range and using geometric mean as the denominator for international normalized ratio calculation. For overall satisfaction, 179 of 206 (86.9%) participant laboratories reported being satisfied or very satisfied. Improvements in coagulation laboratory practices in Thailand were observed in every step of the total testing process. However, additional improvements are still needed, such as determination and use of a local reference range. © 2016 John Wiley & Sons Ltd.

  1. HEPATIC FUNCTION AFTER GENETICALLY-ENGINEERED PIG LIVER TRANSPLANTATION IN BABOONS

    PubMed Central

    Ekser, Burcin; Echeverri, Gabriel J.; Hassett, Andrea Cortese; Yazer, Mark H.; Long, Cassandra; Meyer, Michael; Ezzelarab, Mohamed; Lin, Chih Che; Hara, Hidetaka; van der Windt, Dirk J.; Dons, Eefje M.; Phelps, Carol; Ayares, David; Cooper, David K.C.; Gridelli, Bruno

    2010-01-01

    Background If ‘bridging’ to allotransplantation is to be achieved by a pig liver xenograft, adequate hepatic function needs to be assured. Methods We have studied hepatic function in baboons after transplantation of livers from α1,3-galactosyltransferase gene-knockout (GTKO,n=1) or GTKO pigs transgenic for CD46 (GTKO/CD46,n=5). Monitoring was by liver function tests and coagulation parameters. Pig-specific proteins in the baboon serum/plasma were identified by Western blot. In 4 baboons, coagulation factors were measured. The results were compared with values from healthy humans, baboons, and pigs. Results Recipient baboons died or were euthanized after 4-7 days following internal bleeding associated with profound thrombocytopenia. However, parameters of liver function, including coagulation, remained in the near-normal range, except for some cholestasis. Western blot demonstrated that pig proteins (albumin, fibrinogen, haptoglobin, plasminogen) were produced by the liver from day 1. Production of several pig coagulation factors was confirmed. Conclusions After the transplantation of genetically-engineered pig livers into baboons (1) many parameters of hepatic function, including coagulation, were normal or near-normal; (2) there was evidence for production of pig proteins, including coagulation factors, and (3) these appeared to function adequately in baboons, though inter-species compatibility of such proteins remains to be confirmed. PMID:20606605

  2. Oxidation and coagulation of humic substances by potassium ferrate.

    PubMed

    Graham, N J D; Khoi, T T; Jiang, J-Q

    2010-01-01

    Ferrate (FeO₄²⁻) is believed to have a dual role in water treatment, both as oxidant and coagulant. Few studies have considered the coagulation effect in detail, mainly because of the difficulty of separating the oxidation and coagulation effects. This paper summarises some preliminary results from laboratory-based experiments that are investigating the coagulation reaction dynamically via a PDA instrument, between ferrate and humic acid (HA) at different doses and pH values, and comparing the observations with the use of ferric chloride. The PDA output gives a comparative measure of the rate of floc growth and the magnitude of floc formation. The results of the tests show some significant differences in the pattern of behaviour between ferrate and ferric chloride. At pH 5 the chemical dose range (as Fe) corresponding to HA coagulation was much broader for ferrate than ferric chloride, and the optimal Fe dose was greater. Ferrate oxidation appears to increase the hydrophilic and electronegative nature of the HA leading to an extended region of charge neutralisation. A consequence of the ferrate oxidation is that the extent of HA removal was slightly lower ( approximately 5%) than with ferric chloride. At pH 7, in the sweep flocculation domain, ferrate achieved much greater floc formation than ferric chloride, but a substantially lower degree of HA removal.

  3. A sample-to-result system for blood coagulation tests on a microfluidic disk analyzer

    PubMed Central

    Lin, Chia-Hui; Liu, Cheng-Yuan; Shih, Chih-Hsin; Lu, Chien-Hsing

    2014-01-01

    In this report, we describe in detail a microfluidic analyzer, which is able to conduct blood coagulation tests using whole blood samples. Sample preparation steps, such as whole blood aliquoting and metering, plasma separation, decanting, and mixing with reagents were performed in sequence through microfluidic functions integrated on a disk. Both prothrombin time (PT) and activated partial thromboplastin time (aPTT) were carried out on the same platform and the test results can be reported in 5 min. Fifty clinical samples were tested for both PT and aPTT utilizing the microfluidic disk analyzer and the instrument used in hospitals. The test results showed good correlation and agreement between the two instruments. PMID:25332733

  4. Adaptive force sonorheometry for assessment of whole blood coagulation.

    PubMed

    Mauldin, F William; Viola, Francesco; Hamer, Theresa C; Ahmed, Eman M; Crawford, Shawna B; Haverstick, Doris M; Lawrence, Michael B; Walker, William F

    2010-05-02

    Viscoelastic diagnostics that monitor the hemostatic function of whole blood (WB), such as thromboelastography, have been developed with demonstrated clinical utility. By measuring the cumulative effects of all components of hemostasis, viscoelastic diagnostics have circumvented many of the challenges associated with more common tests of blood coagulation. We describe a new technology, called sonorheometry, that adaptively applies acoustic radiation force to assess coagulation function in WB. The repeatability (precision) of coagulation parameters was assessed using citrated WB samples. A reference range of coagulation parameters, along with corresponding measurements from prothrombin time (PT) and partial thromboplastin time (PTT), were obtained from WB samples of 20 healthy volunteers. In another study, sonorheometry monitored anticoagulation with heparin (0-5 IU/ml) and reversal from varied dosages of protamine (0-10 IU/ml) in heparinized WB (2 IU/ml). Sonorheometry exhibited low CVs for parameters: clot initiation time (TC1), <7%; clot stabilization time (TC2), <6.5%; and clotting angle (theta), <3.5%. Good correlation was observed between clotting times, TC1 and TC2, and PTT (r=0.65 and 0.74 respectively; n=18). Linearity to heparin dosage was observed with average linearity r>0.98 for all coagulation parameters. We observed maximum reversal of heparin anticoagulation at protamine to heparin ratios of 1.4:1 from TC1 (P=0.6) and 1.2:1 from theta (P=0.55). Sonorheometry is a non-contact method for precise assessment of WB coagulation. Copyright 2010 Elsevier B.V. All rights reserved.

  5. Activation of coagulation and endothelium with concurrent impairment of anticoagulant mechanisms in patients with typhoid fever.

    PubMed

    de Jong, Hanna K; Parry, Chris M; van der Vaart, Thomas W; Kager, Liesbeth M; van den Ende, Stannie J; Maude, Rapeephan R; Wijedoru, Lalith; Ghose, Aniruddha; Hassan, Mohammed U; Hossain, Mohammed A; Dondorp, Arjan M; Baker, Steve; Faiz, M Abul; Meijers, Joost C M; Wiersinga, W Joost

    2018-05-07

    Typhoid fever caused by Salmonella Typhi remains a major burden worldwide. Gastrointestinal bleeding can be seen in up to 10 percent of patients and may be fatal. The coagulopathy, which may be the driver of this severe complication in patients with typhoid fever, however is ill defined. The aim of this study was to evaluate the activation of coagulation, anticoagulation, and fibrinolysis in patients with acute typhoid fever. Parameters of coagulation and fibrinolysis were measured in 28 hospitalized patients with culture-confirmed or PCR-confirmed typhoid fever and compared to 38 age- and sex-matched healthy volunteers. Patients demonstrated activation of the coagulation system, as reflected by elevated in vitro thrombin generation and high plasma levels of fibrinogen, D-dimer and prothrombin fragment F1 + 2 in concert with consumption of coagulation factors resulting in a prolonged prothrombin-time and activated-partial-thromboplastin-time. Concurrently, the anticoagulant proteins, protein C and antithrombin, were significantly lower in comparison to healthy controls. Patients also demonstrated evidence of activation and inhibition of fibrinolysis and a marked activation of endothelial cells. The extent of coagulation activation was associated with the course of the disease, repeated testing during convalescence showed a return toward normal values. Activation of coagulation is an important clinical feature of typhoid fever and is associated with severity of disease. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. ANFIS-based modelling for coagulant dosage in drinking water treatment plant: a case study.

    PubMed

    Heddam, Salim; Bermad, Abdelmalek; Dechemi, Noureddine

    2012-04-01

    Coagulation is the most important stage in drinking water treatment processes for the maintenance of acceptable treated water quality and economic plant operation, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, pH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Traditionally, jar tests are used to determine the optimum coagulant dosage. However, this is expensive and time-consuming and does not enable responses to changes in raw water quality in real time. Modelling can be used to overcome these limitations. In this study, an Adaptive Neuro-Fuzzy Inference System (ANFIS) was used for modelling of coagulant dosage in drinking water treatment plant of Boudouaou, Algeria. Six on-line variables of raw water quality including turbidity, conductivity, temperature, dissolved oxygen, ultraviolet absorbance, and the pH of water, and alum dosage were used to build the coagulant dosage model. Two ANFIS-based Neuro-fuzzy systems are presented. The two Neuro-fuzzy systems are: (1) grid partition-based fuzzy inference system (FIS), named ANFIS-GRID, and (2) subtractive clustering based (FIS), named ANFIS-SUB. The low root mean square error and high correlation coefficient values were obtained with ANFIS-SUB method of a first-order Sugeno type inference. This study demonstrates that ANFIS-SUB outperforms ANFIS-GRID due to its simplicity in parameter selection and its fitness in the target problem.

  7. Integrated process for the removal of emulsified oils from effluents in the steel industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benito, J.M.; Rios, G.; Gutierrez, B.

    1999-11-01

    Emulsified oils contained in aqueous effluents from cold-rolling mills of the steel industry can be effectively removed via an integrated process consisting of a coagulation/flocculation stage followed by ultrafiltration of the resulting aqueous phase. The effects of CaCl{sub 2}, NaOH, and lime on the stability of different industrial effluents were studied in the coagulation experiments. The flocculants tested were inorganic prehydrolyzed aluminum salts and quaternary polyamines. Ultrafiltration of the aqueous phase from the coagulation/flocculation stage was carried out in a stirred cell using Amicon PM30 and XM300 organic membranes. Permeate fluxes were measured for industrial effluents to which the indicatedmore » coagulants and flocculants had been added. Oil concentrations in the permeate were 75% lower than the limits established by all European Union countries. Complete regeneration of the membrane was accomplished with an aqueous solution of a commercial detergent.« less

  8. Acute generalized, widespread bleeding. Diagnosis and management.

    PubMed

    Rocha, E; Páramo, J A; Montes, R; Panizo, C

    1998-11-01

    Acute generalized, widespread bleeding is often related to disseminated intravascular coagulation (DIC), a pathologic process which complicates the clinical course of many diseases and is characterized by huge amounts of thrombin and plasmin within the circulation. The final result is the consumption of platelets, coagulation factors and inhibitors, as well as secondary hyperfibrinolysis, all leading to diffuse hemorrhage and microthromboses. This review article examines the present attitudes to the diagnosis and treatment of overt DIC in clinical practice, emphasizing the importance of an accurate differential diagnosis from some other processes characterized by acute generalized, widespread bleeding. The authors have been working in this field, both at experimental and clinical levels, contributing original papers for many years. In addition, material examined in this review includes articles published in journals covered by MedLine, recent reviews in journals with high impact factor and in relevant books on hemostasis and thrombosis. DIC is an intermediary mechanism of disease which complicates the clinical course of many well-known disorders. Although the systemic hemorrhagic syndrome is the predominant clinical manifestation, massive intravascular thrombosis frequently occurs contributing to ischemia and associated organ damage, making the mortality rate of this condition high. Current concepts on the pathophysiology, laboratory diagnosis and management of DIC are presented. Complex pathophysiological interrelations make the diagnosis of the etiology of the DIC difficult in clinical practice, although simple tests are useful for identification of patients with the process. Laboratory diagnosis of DIC is mainly based on screening assays, which allow a rapid diagnosis, whereas some other highly sensitive but more complex assays are not always available to routine clinical laboratories. The management of DIC is based on the treatment of the underlying disease, supportive and replacement therapies and the control of the coagulation mechanisms. Although some advances have been achieved, management decisions are still controversial, so that therapy should be highly individualized depending on the nature of the DIC and severity of clinical symptoms. Many syndromes sharing common findings with DIC, such as primary hyperfibrinolysis or thrombotic thrombocytopenic purpura, should be excluded. Finally, new therapeutic approaches to the management of this potentially catastrophic syndrome are required.

  9. Polymorphisms of the factor VII gene associated with the low activities of vitamin K-dependent coagulation factors in one-month-old infants.

    PubMed

    Ito, Koichi; Goto, Kenji; Sugiura, Tokio; Muramatsu, Kanji; Ando, Toshihiro; Maniwa, Hiroko; Yokoyama, Takao; Sugiyama, Kohachiro; Togari, Hajime

    2007-01-01

    Despite administration of vitamin K (VK), some infants show lower activity of VK-dependent coagulation factors and they could develop intracranial hemorrhage. For preventing VK deficiency bleeding (VKDB) in infants, oral administration of VK and a screening test for VK deficiency are carried out in Japan. For the screening, the total activity of VK-dependent coagulation factors is measured using a commercial product, Normotest. This study was undertaken to clarify the importance of the following genetic and environmental factors on the coagulation status in one-month-old infants: two polymorphisms in the factor VII gene, -323P0/10 (a 10-bp insertion in the promoter region at position -323) and R353Q (the replacement of arginine [R] with glutamine [Q] at residue 353) and sex, age, gestational age, birth weight, and feeding regimen. Two hundred Japanese infants (34.6 +/- 4.0 days old) were screened for VK-dependent coagulation activity with Normotest and were genotyped for the two polymorphisms. Among the subjects screened, 18 infants (9%) carried the P10 allele and 26 (13%) carried the R353Q allele. Multiple regression analysis showed that the 10-bp inserted (P10) allele or the Q allele was associated with the lower coagulation activities. The coagulation activities for the R/Q genotype were significantly lower than those for the R/R genotype and those for the P0/P10 genotype were significantly lower than those for the P0/P0 genotype. Therefore, infants who carry the P10 allele or the Q allele show lower activity of VK-dependent coagulation factors. These infants may have a higher risk of VKDB manifestation.

  10. Coagulation Imbalance and Neurocognitive Functioning in Older HIV+ Adults on Suppressive Antiretroviral Therapy

    PubMed Central

    Montoya, Jessica l.; Iudicello, Jennifer; Oppenheim, Hannah A.; Fazeli, Pariya l.; Potter, Michael; MA, Qing; Mills, Paul J.; Ellis, Ronald J.; Grant, Igor; Letendre, Scott l.; Moore, David J.

    2017-01-01

    Objectives To compare plasma biomarkers of coagulation between HIV-infected individuals and HIV-uninfected controls and to assess the impact of disturbances in coagulation on neurocognitive functioning in HIV. Design Cross-sectional study of 66 antiretroviral therapy-treated virally suppressed HIV-infected and 34 HIV-uninfected older (≥50 years of age) adults. Methods Participants completed standardized neurobehavioral and neuromedical assessments. Neurocognitive functioning was evaluated using a well-validated comprehensive neuropsychological battery. Plasma biomarkers associated with procoagulation (fibrinogen, p-selectin, tissue factor, and von Willebrand factor), anticoagulation (antithrombin, protein C, and thrombomodulin), fibrinolysis (d-dimer, plasminogen activator inhibitor-1, and plasminogen) were collected. Multivariable linear regression was used to test the interaction of HIV and coagulation on neurocognitive functioning. Results Most participants were male (78.0%) and non-Hispanic white (73.0%) with a mean age of 57.8 years. Among HIV-infected participants, mean estimated duration of HIV infection was 19.4 years and median current CD4+ cell count was 654 cells/mm3. Levels of soluble biomarkers of procoagulation, anticoagulation, and fibrinolysis were comparable between the HIV serostatus groups. Coagulation and HIV had an interacting effect on neurocognitive functioning, such that greater coagulation imbalance was associated with poorer neurocognitive functioning among the HIV-infected participants. The moderating effect of coagulation on neurocognition was driven by procoagulant but not anticoagulant or fibrinolytic biomarkers. Conclusions Elevated levels of procoagulants may exert a particularly detrimental effect on neurocognitive functioning among older HIV-infected persons. A better understanding of the specific role of coagulation in the etiology of HIV-associated neurocognitive disorders may lead to treatments aimed at reducing coagulopathy, thereby improving neurocognitive outcomes. PMID:28099190

  11. Coagulation imbalance and neurocognitive functioning in older HIV-positive adults on suppressive antiretroviral therapy.

    PubMed

    Montoya, Jessica L; Iudicello, Jennifer; Oppenheim, Hannah A; Fazeli, Pariya L; Potter, Michael; Ma, Qing; Mills, Paul J; Ellis, Ronald J; Grant, Igor; Letendre, Scott L; Moore, David J

    2017-03-27

    The aim of this study was to compare plasma biomarkers of coagulation between HIV-infected individuals and HIV-uninfected controls and to assess the impact of disturbances in coagulation on neurocognitive functioning in HIV. A cross-sectional study of 66 antiretroviral therapy treated, virally suppressed, HIV-infected and 34 HIV-uninfected older (≥50 years of age) adults. Participants completed standardized neurobehavioral and neuromedical assessments. Neurocognitive functioning was evaluated using a well validated comprehensive neuropsychological battery. Plasma biomarkers associated with procoagulation (fibrinogen, p-selectin, tissue factor and von Willebrand factor), anticoagulation (antithrombin, protein C and thrombomodulin), fibrinolysis (d-dimer, plasminogen activator inhibitor-1 and plasminogen) were collected. Multivariable linear regression was used to test the interaction of HIV and coagulation on neurocognitive functioning. Most participants were male (78.0%) and non-Hispanic white (73.0%) with a mean age of 57.8 years. Among HIV-infected participants, mean estimated duration of HIV infection was 19.4 years and median current CD4 cell count was 654 cells/μl. Levels of soluble biomarkers of procoagulation, anticoagulation and fibrinolysis were comparable between the HIV serostatus groups. Coagulation and HIV had an interacting effect on neurocognitive functioning, such that greater coagulation imbalance was associated with poorer neurocognitive functioning among the HIV-infected participants. The moderating effect of coagulation on neurocognition was driven by procoagulant but not anticoagulant or fibrinolytic biomarkers. Elevated levels of procoagulants may exert a particularly detrimental effect on neurocognitive functioning among older HIV-infected persons. A better understanding of the specific role of coagulation in the cause of HIV-associated neurocognitive disorders may lead to treatments aimed at reducing coagulopathy, thereby improving neurocognitive outcomes.

  12. Effects of hemolysis and lipemia interference on kaolin-activated thromboelastography, and comparison with conventional coagulation tests.

    PubMed

    Tang, Ning; Jin, Xi; Sun, Ziyong; Jian, Cui

    2017-04-01

    The effects of hemolysis and lipemia on thromboelastography (TEG) analysis have been scarcely evaluated in human samples, and neglected in clinical practice. We aimed to investigate the effects of in vitro mechanical hemolysis and lipemia on TEG analysis and conventional coagulation tests. Twenty-four healthy volunteers were enrolled in the study. Besides the controls, three groups with slight, moderate and severe mechanical hemolysis were constituted according to free hemoglobin (Hb) concentrations of 0.5-1.0, 2.0-6.0 and 7.0-13.0 g/L, respectively; and three groups with mild, moderate and high lipemia were established according to triglyceride concentrations of ∼6.0, ∼12.0, and ∼18.0 mmol/L, respectively. Four TEG parameters, reaction time (R), coagulation time (K), angle (α), and maximum amplitude (MA), were measured alongside conventional plasma tests including prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrinogen (FIB) by mechanical method, and platelet count by optical method. Results showed that the median R and MA values at moderate and severe hemolysis and K at severe hemolysis exceeded respective reference intervals, and were considered unacceptable. Median values of TEG parameters in lipemic samples were all within reference intervals. Bias values of conventional plasma tests PT, APTT and FIB in hemolyzed or lipemic samples were all lower than the Clinical Laboratory Improvement Amendments (CLIA) allowable limits. Bias values of platelet count at moderate to severe hemolysis and lipemia exceeded the CLIA allowable limits. In conclusion, the detection of TEG was in general more affected by mechanical hemolysis than plasma coagulation tests. Pre-analytical variables should be taken into account when unexpected TEG results are obtained.

  13. Genetic Factors Influencing Coagulation Factor XIII B-Subunit Contribute to Risk of Ischemic Stroke.

    PubMed

    Hanscombe, Ken B; Traylor, Matthew; Hysi, Pirro G; Bevan, Stephen; Dichgans, Martin; Rothwell, Peter M; Worrall, Bradford B; Seshadri, Sudha; Sudlow, Cathie; Williams, Frances M K; Markus, Hugh S; Lewis, Cathryn M

    2015-08-01

    Abnormal coagulation has been implicated in the pathogenesis of ischemic stroke, but how this association is mediated and whether it differs between ischemic stroke subtypes is unknown. We determined the shared genetic risk between 14 coagulation factors and ischemic stroke and its subtypes. Using genome-wide association study results for 14 coagulation factors from the population-based TwinsUK sample (N≈2000 for each factor), meta-analysis results from the METASTROKE consortium ischemic stroke genome-wide association study (12 389 cases, 62 004 controls), and genotype data for 9520 individuals from the WTCCC2 ischemic stroke study (3548 cases, 5972 controls-the largest METASTROKE subsample), we explored shared genetic risk for coagulation and stroke. We performed three analyses: (1) a test for excess concordance (or discordance) in single nucleotide polymorphism effect direction across coagulation and stroke, (2) an estimation of the joint effect of multiple coagulation-associated single nucleotide polymorphisms in stroke, and (3) an evaluation of common genetic risk between coagulation and stroke. One coagulation factor, factor XIII subunit B (FXIIIB), showed consistent effects in the concordance analysis, the estimation of polygenic risk, and the validation with genotype data, with associations specific to the cardioembolic stroke subtype. Effect directions for FXIIIB-associated single nucleotide polymorphisms were significantly discordant with cardioembolic disease (smallest P=5.7×10(-04)); the joint effect of FXIIIB-associated single nucleotide polymorphisms was significantly predictive of ischemic stroke (smallest P=1.8×10(-04)) and the cardioembolic subtype (smallest P=1.7×10(-04)). We found substantial negative genetic covariation between FXIIIB and ischemic stroke (rG=-0.71, P=0.01) and the cardioembolic subtype (rG=-0.80, P=0.03). Genetic markers associated with low FXIIIB levels increase risk of ischemic stroke cardioembolic subtype. © 2015 The Authors.

  14. The role of thromboelastometry in the assessment and treatment of coagulopathy in liver transplant patients.

    PubMed

    Zamper, Raffael Pereira Cezar; Amorim, Thiago Chaves; Costa, Luiz Guilherme Villares da; Takaoka, Flávio; Serpa, Ary

    2017-01-01

    Perioperative monitoring of coagulation is vital to assess bleeding risks, diagnose deficiencies associated with hemorrhage, and guide hemostatic therapy in major surgical procedures, such as liver transplantation. Routine static tests demand long turnaround time and do not assess platelet function; they are determined on plasma at a standard temperature of 37°C; hence these tests are ill-suited for intraoperative use. In contrast, methods which evaluate the viscoelastic properties of whole blood, such as thromboelastogram and rotational thromboelastometry, provide rapid qualitative coagulation assessment and appropriate guidance for transfusion therapy. These are promising tools for the assessment and treatment of hyper- and hypocoagulable states associated with bleeding in liver transplantation. When combined with traditional tests and objective assessment of the surgical field, this information provides ideal guidance for transfusion strategies, with potential improvement of patient outcomes. RESUMO A monitorização perioperatória da coagulação é fundamental para estimar o risco de sangramento, diagnosticar deficiências causadoras de hemorragia e guiar terapias hemostáticas durante procedimentos cirúrgicos de grande porte, como o transplante hepático. Os testes estáticos, comumente usados na prática clínica, são insatisfatórios no intraoperatório, pois demandam tempo e não avaliam a função plaquetária; são determinados no plasma e realizados em temperatura padrão de 37°C. Os métodos que avaliam as propriedades viscoelásticas do sangue total, como o tromboelastograma e a tromboelastometria rotacional, podem suprir as deficiências dos testes estáticos tradicionais, uma vez que permitem avaliar a coagulação de forma rápida e qualitativa, guiando a terapia transfusional de forma adequada. A tromboelastometria rotacional mostrou-se promissora na avaliação e no tratamento de estados de hipercoagulação e hipocoagulação, associados a sangramento no transplante hepático. Estas informações, combinadas com os testes tradicionais e uma avaliação objetiva do campo cirúrgico, promovem um cenário ótimo para guiar as estratégias transfusionais e potencialmente melhorar o desfecho destes pacientes.

  15. Utilization of stat test priority in the clinical laboratory: a College of American Pathologists q-probes study of 52 institutions.

    PubMed

    Volmar, Keith E; Wilkinson, David S; Wagar, Elizabeth A; Lehman, Christopher M

    2013-02-01

    Utilization of stat testing priority is a balance between safe, efficient patient management and resource expenditure. To determine the rate of stat testing, compare rates among institutions, and determine the distribution of turnaround time expectations for different turnaround time priorities. During a 7-day period, participants prospectively determined the total number of chemistry, hematology, and coagulation billable tests from inpatients and emergency department patients. Among these, the total numbers of billable tests performed stat were identified. Laboratories also reported the levels of test priority they offered and turnaround expectations for each level of test priority. Fifty institutions submitted data for the study, with 2 additional participants submitting partial results. Participants identified 639 589 chemistry, hematology, and coagulation billable tests, with 229 896 (35.9%) performed stat. The stat rate varied from 21.3% at the 10th percentile to 55.4% at the 90th percentile, with a median of 37.0% of participants' tests performed stat. Laboratories include a mean of 206 tests in chemistry, hematology, and coagulation test menus, with 67% of these tests offered stat. The fraction of the test menu offered stat varied from 29.0% at the 10th percentile to 97.8% at the 90th percentile, with a median of 73.3% of tests on the menu offered stat. The most common number of testing priorities offered by participating laboratories was 3 (44.2%). Among the 52 participating laboratories, the median stat testing rate was 37.0% and a median 73.3% of the test menu was offered stat.

  16. Rotational Thromboelastometry or Conventional Coagulation Tests in Liver Transplantation: Comparing Blood Loss, Transfusions, and Cost.

    PubMed

    Smart, Laura; Mumtaz, Khalid; Scharpf, Danielle; Gray, Nicole O'Bleness; Traetow, Daniel; Black, Sylvester; Michaels, Anthony J; Elkhammas, Elmahdi; Kirkpatrick, Robert; Hanje, A James

    Orthotopic liver transplantation (OLT) can be associated with significant bleeding requiring multiple blood product transfusions. Rotational thromboelastometry (ROTEM) is a point-of-care device that has been used to monitor coagulation during OLT. Whether it reduces blood loss/transfusions during OLT remains controversial. We aim to compare ROTEM with conventional coagulation tests (aPTT, PT, INR, platelet count, fibrinogen) to guide transfusion of platelets, cryoprecipitate, and fresh frozen plasma (FFP) during OLT over 3 years. Thirty-four patients who had transfusions guided by ROTEM were compared to 34 controls who received transfusions guided by conventional coagulation tests (CCT). Intraoperative blood loss, type/ amount of blood products transfused, and direct costs were compared between the two groups. The ROTEM group had significantly less intra-operative blood loss (2.0 vs. 3.0 L, p = 0.04) and fresh frozen plasma (FFP) transfusion (4 units vs. 6.5 units, p = 0.015) compared to the CCT group (2.0L vs. 3.0L, p = 0.04). However, total number of patients transfused cryoprecipitate was increased in ROTEM (n = 25;73%) as compared to CCT (n = 19; 56%), p = 0.033. The direct cost of blood products plus testing was reduced in the ROTEM group ($113,142.89 vs. $127,814.77). In conclusion implementation of a ROTEM-guided transfusion algorithm resulted in a reduction in intra-operative blood loss, FFP transfusion and a decrease in direct cost during OLT. ROTEM is a useful and safe point of care device in OLT setting.

  17. The role of heparin in sepsis: much more than just an anticoagulant.

    PubMed

    Li, Xu; Ma, Xiaochun

    2017-11-01

    Despite progress in antibiotic treatment, mechanical ventilation, fluid resuscitation and blood glucose maintenance, sepsis remains a cause of high mortality in the intensive care unit to date, there are no proven treatment strategies for the routine management of septic patients. The extensive interaction between inflammation and coagulation contributes to the basic pathophysiology of sepsis. Thus, the agents that attenuate the activation of both inflammation and coagulation may improve the outcome in sepsis. Apart from the well-known anticoagulant effects of heparin, it also possesses various immunomodulatory properties and protects glycocalyx from shedding. Hence, heparin seems to be such an agent. Immunothrombosis plays an important role in early host defence against bacterial dissemination, thus the proper timing for anticoagulant therapy should be determined. We review the available experimental and clinical data supporting the use of heparin in sepsis. At this time the use of heparin in the treatment of sepsis is conflicting. Future trials of heparin therapy for sepsis should concentrate on the very severely ill patients, in whom benefit is most likely to be demonstrated. © 2017 John Wiley & Sons Ltd.

  18. Venous thromboembolism: role of pharmacists and managed care considerations.

    PubMed

    Horner, Tuesdy; Mahan, Charles E

    2017-12-01

    Venous thromboembolism (VTE) includes deep vein thrombosis and pulmonary embolism. Anticoagulation is used in patients with VTE to reduce the risk of recurrent VTE and VTE-related death. The overall incidence of VTE is 1 to 2 per 1000 person-years. Long-term mortality for patients with VTE is poor, with 25% of patients not surviving 7 days and nearly 40% not surviving the first year. Coagulation disorders demand effective anticoagulant therapy to avoid complications, especially recurrent VTE and VTE-related death. For more than 60 years, warfarin has been the cornerstone of therapy for patients requiring anticoagulation and was the sole oral anticoagulant available in the United States until 2010. Since then, the FDA has approved 5 direct-acting oral anticoagulants (DOACs) that inhibit single coagulation factors (factor Xa and thrombin). DOACs provide predictable anticoagulation with fixed dosing, easier perioperative management, no routine laboratory monitoring, and fewer food-drug interactions. However, when choosing DOACs, clinicians must consider several issues in addition to efficacy and safety before employing these therapies, including patient-specific factors, adherence and persistence with therapy, and their cost-effectiveness for clinical use.

  19. A novel mutation in the FGB: c.1105C>T turns the codon for amino acid Bβ Q339 into a stop codon causing hypofibrinogenemia.

    PubMed

    Marchi, Rita; Brennan, Stephen; Meyer, Michael; Rojas, Héctor; Kanzler, Daniela; De Agrela, Marisela; Ruiz-Saez, Arlette

    2013-03-01

    Routine coagulation tests on a 14year-old male with frequent epistaxis showed a prolonged thrombin time together with diminished functional (162mg/dl) and gravimetric (122mg/dl) fibrinogen concentrations. His father showed similar aberrant results and sequencing of the three fibrinogen genes revealed a novel heterozygous nonsense mutation in the FGB gene c.1105C>T, which converts the codon for residue Bβ 339Q to stop, causing deletion of Bβ chain residues 339-461. Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) and RP-HPLC (reverse-phase high-pressure liquid chromatography) of purified fibrinogen showed only normal Aα, Bβ, and γ chains, indicating that molecules with the truncated 37,990Da β chain were not secreted into plasma. Functional analysis showed impaired fibrin polymerization, fibrin porosity, and elasticity compared to controls. By laser scanning confocal microscopy the patient's fibers were slightly thinner than normal. Electrospray ionization mass spectrometry (ESI MS) presented normal sialylation of the oligosaccharide chains, and liver function tests showed no evidence of liver dysfunction that might explain the functional abnormalities. Copyright © 2012 Elsevier Inc. All rights reserved.

  20. High prevalence of patent foramen ovale in migraine with aura.

    PubMed

    Ferrarini, Giovanni; Malferrari, Giovanni; Zucco, Riccardo; Gaddi, Oscar; Norina, Marcello; Pini, Luigi Alberto

    2005-04-01

    In this study we evaluated the presence of patent foramen ovale (PFO) in a cohort of 25 consecutive patients suffering from migraine with aura (MA) during an attack presenting to the emergency ward of an Italian hospital. Patients underwent brain magnetic resonance imaging (MRI) with contrast medium, routine coagulation tests, contrast transcranial echocolour-coded sonography (c-TCCS) and transoesophageal echocardiography (TEE). Of the enrolled patients, 88.7% showed a PFO according to the c-TCCS test, whereas only in 72% TEE confirmed the presence of PFO. This discordance could be due to the fact that c-TCCS is more sensitive even with shunts with minimal capacity also located in the pulmonary vasculature. After surgical treatment of the PFO, MA disappeared within two months. Also, the treatment with warfarin as well as with acetylsalicylic acid and flunarizine was able to dramatically reduce the frequency of migraine attacks. These data indicate a higher prevalence of PFO in MA vs. normal population (OR=2.92) and could suggest that the presence of arteriovenous (AV) shunts could represent a trigger for MA attacks as well as for stroke, but more studies are needed to confirm this preliminary hypothesis.

  1. Proteins, Platelets, and Blood Coagulation at Biomaterial Interfaces

    PubMed Central

    Xu, Li-Chong; Bauer, James; Siedlecki, Christopher A.

    2015-01-01

    Blood coagulation and platelet adhesion remain major impediments to the use of biomaterials in implantable medical devices. There is still significant controversy and question in the field regarding the role that surfaces play in this process. This manuscript addresses this topic area and reports on state of the art in the field. Particular emphasis is placed on the subject of surface engineering and surface measurements that allow for control and observation of surface-mediated biological responses in blood and test solutions. Appropriate use of surface texturing and chemical patterning methodologies allow for reduction of both blood coagulation and platelet adhesion, and new methods of surface interrogation at high resolution allow for measurement of the relevant biological factors. PMID:25448722

  2. Enzymatically oxidized phospholipids restore thrombin generation in coagulation factor deficiencies.

    PubMed

    Slatter, David A; Percy, Charles L; Allen-Redpath, Keith; Gajsiewicz, Joshua M; Brooks, Nick J; Clayton, Aled; Tyrrell, Victoria J; Rosas, Marcela; Lauder, Sarah N; Watson, Andrew; Dul, Maria; Garcia-Diaz, Yoel; Aldrovandi, Maceler; Heurich, Meike; Hall, Judith; Morrissey, James H; Lacroix-Desmazes, Sebastien; Delignat, Sandrine; Jenkins, P Vincent; Collins, Peter W; O'Donnell, Valerie B

    2018-03-22

    Hemostatic defects are treated using coagulation factors; however, clot formation also requires a procoagulant phospholipid (PL) surface. Here, we show that innate immune cell-derived enzymatically oxidized phospholipids (eoxPL) termed hydroxyeicosatetraenoic acid-phospholipids (HETE-PLs) restore hemostasis in human and murine conditions of pathological bleeding. HETE-PLs abolished blood loss in murine hemophilia A and enhanced coagulation in factor VIII- (FVIII-), FIX-, and FX-deficient human plasma . HETE-PLs were decreased in platelets from patients after cardiopulmonary bypass (CPB). To explore molecular mechanisms, the ability of eoxPL to stimulate individual isolated coagulation factor/cofactor complexes was tested in vitro. Extrinsic tenase (FVIIa/tissue factor [TF]), intrinsic tenase (FVIIIa/FIXa), and prothrombinase (FVa/FXa) all were enhanced by both HETE-PEs and HETE-PCs, suggesting a common mechanism involving the fatty acid moiety. In plasma, 9-, 15-, and 12-HETE-PLs were more effective than 5-, 11-, or 8-HETE-PLs, indicating positional isomer specificity. Coagulation was enhanced at lower lipid/factor ratios, consistent with a more concentrated area for protein binding. Surface plasmon resonance confirmed binding of FII and FX to HETE-PEs. HETE-PEs increased membrane curvature and thickness, but not surface charge or homogeneity, possibly suggesting increased accessibility to cations/factors. In summary, innate immune-derived eoxPL enhance calcium-dependent coagulation factor function, and their potential utility in bleeding disorders is proposed.

  3. Enzymatically oxidized phospholipids restore thrombin generation in coagulation factor deficiencies

    PubMed Central

    Slatter, David A.; Percy, Charles L.; Allen-Redpath, Keith; Gajsiewicz, Joshua M.; Brooks, Nick J.; Tyrrell, Victoria J.; Lauder, Sarah N.; Watson, Andrew; Dul, Maria; Garcia-Diaz, Yoel; Aldrovandi, Maceler; Heurich, Meike; Hall, Judith; Lacroix-Desmazes, Sebastien; Delignat, Sandrine; Jenkins, P. Vincent; Collins, Peter W.; O’Donnell, Valerie B.

    2018-01-01

    Hemostatic defects are treated using coagulation factors; however, clot formation also requires a procoagulant phospholipid (PL) surface. Here, we show that innate immune cell–derived enzymatically oxidized phospholipids (eoxPL) termed hydroxyeicosatetraenoic acid–phospholipids (HETE-PLs) restore hemostasis in human and murine conditions of pathological bleeding. HETE-PLs abolished blood loss in murine hemophilia A and enhanced coagulation in factor VIII- (FVIII-), FIX-, and FX-deficient human plasma . HETE-PLs were decreased in platelets from patients after cardiopulmonary bypass (CPB). To explore molecular mechanisms, the ability of eoxPL to stimulate individual isolated coagulation factor/cofactor complexes was tested in vitro. Extrinsic tenase (FVIIa/tissue factor [TF]), intrinsic tenase (FVIIIa/FIXa), and prothrombinase (FVa/FXa) all were enhanced by both HETE-PEs and HETE-PCs, suggesting a common mechanism involving the fatty acid moiety. In plasma, 9-, 15-, and 12-HETE-PLs were more effective than 5-, 11-, or 8-HETE-PLs, indicating positional isomer specificity. Coagulation was enhanced at lower lipid/factor ratios, consistent with a more concentrated area for protein binding. Surface plasmon resonance confirmed binding of FII and FX to HETE-PEs. HETE-PEs increased membrane curvature and thickness, but not surface charge or homogeneity, possibly suggesting increased accessibility to cations/factors. In summary, innate immune-derived eoxPL enhance calcium-dependent coagulation factor function, and their potential utility in bleeding disorders is proposed. PMID:29563336

  4. Short communication: Effects of pregnancy on milk yield, composition traits, and coagulation properties of Holstein cows.

    PubMed

    Penasa, M; De Marchi, M; Cassandro, M

    2016-06-01

    The aim of this study was to investigate the effect of pregnancy stage on milk yield, composition traits, and milk coagulation properties in Italian Holstein cattle. The data set included 25,729 records from 3,995 first-parity cows calving between August 2010 and August 2013 in 167 herds. The traits analyzed were milk yield (kg/d), fat (%), protein (%), casein (%), and lactose (%) contents, pH, somatic cell score, rennet coagulation time (min), and curd firmness (mm). To better understand the effect of gestation on the aforementioned traits, each record was assigned to one of the following classes of pregnancy stage: (1) nonpregnant, (2) pregnant from 1 to 120d, (3) pregnant from 121 to 210d, and (4) pregnant from 211 to 310d. Gestation stage significantly influenced all studied traits with the exception of somatic cell score. Milk production decreased and milk quality improved from the fourth month of pregnancy onward. For all traits, nonpregnant cows performed very similarly to cows in the first period of gestation. Rennet coagulation time and curd firmness were influenced by pregnancy stage, especially in the last weeks of gestation when milk had better coagulation characteristics; this information should be accounted for to adjust test-day records in genetic evaluation of milk coagulation properties. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of the treatment of reverse osmosis concentrates from municipal wastewater reclamation by coagulation and granular activated carbon adsorption.

    PubMed

    Sun, Ying-Xue; Yang, Zhe; Ye, Tao; Shi, Na; Tian, Yuan

    2016-07-01

    Reverse osmosis concentrate (ROC) from municipal wastewater reclamation reverse osmosis (mWRRO) contains elevated concentrations of contaminants which pose potential risks to aquatic environment. The treatment of ROC from an mWRRO using granular activated carbon (GAC) combined pretreatment of coagulation was optimized and evaluated. Among the three coagulants tested, ferric chloride (FeCl3) presented relatively higher DOC removal efficiency than polyaluminium chloride and lime at the same dosage and coagulation conditions. The removal efficiency of DOC, genotoxicity, and antiestrogenic activity concentration of the ROC could achieve 16.9, 18.9, and 39.7 %, respectively, by FeCl3 coagulation (with FeCl3 dosage of 180.22 mg/L), which can hardly reduce UV254 and genotoxicity normalized by DOC of the DOM with MW <5 kDa. However, the post-GAC adsorption column (with filtration velocity of 5.7 m/h, breakthrough point adsorption capacity of 0.22 mg DOC/g GAC) exhibited excellent removal efficiency on the dominant DOM fraction of MW <5 kDa in the ROC. The removal efficiency of DOC, UV254, and TDS in the ROC was up to 91.8, 96, and 76.5 %, respectively, by the FeCl3 coagulation and post-GAC adsorption. Also, the DOM with both genotoxicity and antiestrogenic activity were completely eliminated by the GAC adsorption. The results suggest that GAC adsorption combined pretreatment of FeCl3 coagulation as an efficient method to control organics, genotoxicity, and antiestrogenic activity in the ROC from mWRRO system.

  6. Partial nephrectomy using radiofrequency incremental bipolar generator with multi electrode probe: experimental study in bench pig kidneys

    PubMed Central

    2014-01-01

    Background The aim of this research project was the realization of an incremental bipolar radiofrequency generator with inline 4-electrode probe for partial renal resection without clamping of the vessels. Methods The experimentation was carried out across two phases: the preliminary realization of a specific generator and an inline multielectrode probe for open surgery (Phase 1); system testing on 27 bench kidneys for a total of 47 partial resection (Phase 2). The parameters evaluated were: power level, generator automatisms, parenchymal coagulation times, needle caliber, thickness of the coagulated tissue “slice”, charring, ergonomy, feasibility of the application of “bolster” stitches. Results The analysis of the results referred to the homogeneity and thickness of coagulation, energy supply times with reference to the power level and caliber of the needles. The optimal results were obtained by using needles of 1.5 mm caliber at power level 5, and with coagulation times of 54 seconds for the first insertion and 30 seconds for the second. Conclusions The experimentation demonstrated that the apparatus, consisting of a generator named “LaparoNewPro” and fitted with a dedicated probe for open surgery, is able to carry out a coagulation of the line of resection of the renal parenchyma in a homogeneous manner, in short times, without tissue charring, and with the possibility of stitching both on coagulated tissue and the caliceal system. The generator automatism based on the flow of the current supplied by each electrode is reliable, and the cessation of energy supply coincides with optimal coagulation. PMID:24410789

  7. Dysfunctional Uterine Bleeding: Questions to Discuss with Your Doctor

    MedlinePlus

    ... exam Your Doctor Might Order the Following Lab Tests or Studies: Pregnancy test Blood tests such as complete blood count, coagulation (clotting) studies, and certain hormone tests (such as thyroid stimulating hormone, cortisol, prolactin, follicle ...

  8. Demonstrating Hemostasis with a Student-Designed Prothrombin Time Test

    ERIC Educational Resources Information Center

    Fardy, Richard Wiley

    1978-01-01

    Describes a blood coagulation test developed by two high school biology students. Although the test lacks some precision, results indicate that the technique is comparable to standard methods used in laboratories. (MA)

  9. Treatment tailoring for factor V deficient patients and perioperative management using global hemostatic coagulation assays.

    PubMed

    Levy-Mendelovich, Sarina; Barg, Assaf Arie; Rosenberg, Nurit; Avishai, Einat; Luboshitz, Jacob; Misgav, Mudi; Kenet, Gili; Livnat, Tami

    2018-07-01

    Congenital factor V deficiency (FVD) is a rare bleeding disorder with an estimated incidence of 1 in 1000,000 in the general population. Since the common coagulation tests do not correlate with the bleeding tendency there is an unmet need to predict FVD patients' bleeding hazard prior to surgical interventions. To optimize treatment prior to surgical interventions, using global coagulation assays, thrombin generation (TG) and rotating thromboelastogram (ROTEM). Our cohort included 5 patients with FVD, 4 severe and one mild. Two of them underwent TG and ROTEM prior to surgical interventions, including ex vivo spiking assays using bypass agents and platelets spiking. All five patients exhibited prolonged PT and PTT, non-dependent on their bleeding tendency. Patient 1, who demonstrated severe bleeding phenotype, underwent surgery treated by combination of APCC (FEIBA) and platelet transfusion. Therapy was guided by global tests (TG as well as ROTEM) results. During the pre and post-operative period neither excessive bleeding nor any thrombosis was noted. In contrast, TG and ROTEM analysis of patient 4 has lead us to perform the surgery without any blood products' support. Indeed, the patient did not encounter any bleeding. Global coagulation assays may be useful ancillary tools guiding treatment decisions in FVD patients undergoing surgical procedures. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Evaluation of chemical coagulation-flocculation aids for the removal of suspended solids and phosphorus from intensive recirculating aquaculture effluent discharge

    USGS Publications Warehouse

    Ebeling, J.M.; Sibrell, P.L.; Ogden, S.R.; Summerfelt, S.T.

    2003-01-01

    An evaluation of two commonly used coagulation-flocculation aids (alum and ferric chloride) was conducted for the supernatant overflow from settling cones used to treat the effluent from microscreen filters in an intensive recirculating aquaculture system. In addition to determining the effectiveness of these aids in removing both suspended solids and phosphorus, a systematic testing of the variables normally encountered in the coagulation-flocculation process was performed. Tests were carried out to evaluate the dosages and conditions (mixing and flocculation stirring speeds, durations, and settling times) required to achieve optimum waste capture. The orthophosphate removal efficiency for alum and ferric chloride were 89 and 93%, respectively, at a dosage of 90 mg/l. Optimum turbidity removal was achieved with a 60 mg/l dosage for both alum and ferric chloride. Both alum and ferric. chloride demonstrated excellent removal of suspended solids from initial TSS values of approximately 100-10 mg/l at a dosage of 90 mg/l. Flocculation and mixing speed played only a minor role in the removal efficiencies for both orthophosphates and suspended solids. Both coagulation-flocculation aids also exhibited excellent settling characteristics, with the majority of the floc quickly settling out in the first 5 min. ?? 2003 Elsevier B.V. All rights reserved.

  11. Evaluation of plant-based natural coagulants for municipal wastewater treatment.

    PubMed

    Maurya, Sandhya; Daverey, Achlesh

    2018-01-01

    In this study, four plant-based natural coagulants (banana peel powder, banana stem juice, papaya seed powder and neem leaf powder) were evaluated for the removal of turbidity, chemical oxygen demand (COD) and total suspended solids (TSS) from municipal wastewater. The experiments were conducted at room temperature without adjusting the initial pH. The maximum turbidity removal was observed with banana peel powder (59.6%) at 0.4 g/L of dosage. Papaya seed powder and banana stem juice were the most effective for TSS removal (66.66%) and COD removal (66.67%), respectively. Significant linear relationships between turbidity and TSS ( R 2  = 0.67-0.88) and turbidity removals and COD removals ( R 2  = 0.68-0.8) were observed. Interestingly, all the natural coagulants tested in the study did not change the pH of the wastewater, which is an added advantage. FTIR analysis of banana peels revealed that functional groups such as carboxylic acid, hydroxyl and aliphatic amines might be responsible for promoting the coagulation-flocculation by neutralizing the charge on impurities in water. Overall, the results suggest the potential of low-cost natural coagulants in municipal wastewater treatment.

  12. Evaluation of carbofuran-mediated toxicity against human lymphocytes and red blood cells in simulated wastewater degraded by coagulation-flocculation.

    PubMed

    Saini, Roli; Kumar, Pradeep; Hira, Sumit Kumar; Manna, Partha Pratim

    2017-06-01

    Coagulation-flocculation in water treatment has been relied upon aluminum (Al) and iron (Fe) salts for treatment of contaminants present in source waters containing dissolved organic compounds. However, water quality deteriorates day by day which makes it urgent to improve the standards of the treatment procedure. Coagulation-flocculation-sedimentation performance of ferric chloride and alum was comparatively investigated for carbofuran treatment in simulated wastewater. Coagulation trails were performed in a jar test at several pH levels and coagulant doses to determine reduction efficiencies of carbofuran degradation and chemical oxygen demand (COD). Effect of carbofuran on proliferation, viability, and direct cytotoxicity was performed using human neuroblastoma cells U-87. Direct toxicity of carbofuran on human mononuclear cells and red blood cells (RBC) was also analyzed. Carbofuran and its derivatives were found to be relatively safe at low concentration (2-5 μM). However, at slightly higher concentration (8 μM), a moderate loss in viability and proliferative potential was observed. Taken together, these results suggest that carbofuran appears to be safe at moderate or low concentration with respect to viability of normal human lymphocytes and RBC.

  13. Effect of leukapheresis on blood coagulation in patients with hyperleukocytic acute myeloid leukemia.

    PubMed

    Van de Louw, Andry

    2017-04-01

    Leukapheresis has been proposed to reduce white blood cell (WBC) count in hyperleukocytic acute myeloid leukemia (AML). However, no survival benefit has been proven and leukapheresis can potentially affect coagulation and worsen bleeding and disseminated intravascular coagulation (DIC). We analyzed the effect of leukapheresis on coagulation tests in a cohort of hyperleukocytic AML patients. Retrospective chart review of hyperleukocytic AML patients who underwent leukapheresis between 2003 and 2014. Blood coagulation tests (platelets, PT, INR, aPTT, fibrinogen, D-Dimers and fibrin degradation products (FDP)) were collected before and after each procedure and DIC score was computed. Transfusions of platelets and coagulation factors were collected. Ninety patients and 129 leukapheresis sessions were screened. After exclusion of the sessions associated with transfusions, we observed in 44 patients a significant decrease in platelets (from 75.69±89.48 to 44.59±47.71.10 9 /L, p=0.001) and fibrinogen (from 4.05±1.29 to 3.35±1.37g/L, p<0.0005) along with an increase in PT (from 14.62±2.73 to 15.62±3.63s, p=0.001), aPTT (from 33.70±6.32 to 39.24±13.53s, p=0.009) and INR (from 1.33±0.2 to 1.45±0.34, p=0.002) after the first procedure. Bleeding complications, all intracerebral hemorrhages, were documented in 3 patients within 24h of leukapheresis. After combining 73 repeat procedures, we observed similar significant results except for the aPTT prolongation. The platelets and PT components of the DIC score, but not the fibrinogen component, were significantly increased after leukapheresis. In hyperleukocytic AML patients, leukapheresis is associated with clinically significant decreases in platelets and fibrinogen and prolonged clotting times. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Application of Ion Exchange Technique to Decontamination of Polluted Water Generated by Fukushima Nuclear Disaster

    NASA Astrophysics Data System (ADS)

    Takeshita, Kenji; Ogata, Takeshi

    By the Fukushima nuclear disaster, large amounts of water and sea water polluted mainly with radioactive Cs were generated and the environment around the nuclear site was contaminated by the fallout from the nuclear site. The coagulation settling process using ferric ferrocyanide and an inorganic coagulant and the adsorption process using ferric ferrocyanide granulated by silica binder were applied to the treatment of polluted water. In the coagulation settling process, Cs was removed completely from polluted water and sea water (DF∼104). In the adsorption process, the recovery of trace Cs (10 ppb) in sea water, which was not suitable for the use of zeolite, was attained successfully. Finally, the recovery of Cs from sewage sludge was tested by a combined process with the hydrothermal process using subcritical water and the coagulation settling process using ferric ferrocyanide. 96% of radioactive Cs was recovered successfully from sewage sludge with the radioactivity of 10,000 Bq/kg.

  15. Characterization of Natural Organic Matter by FeCl3 Coagulation

    NASA Astrophysics Data System (ADS)

    Cahyonugroho, O. H.; Hidayah, E. N.

    2018-01-01

    Natural organic matter (NOM) is heterogenous mixture of organic compounds that enter the water from various decomposition and metabolic reactions, including animal, plant, domestic and industrial wastes. NOM refers to group of carbon-based compounds that are found in surface water and ground water. The aim of the study is to assess organic matter characteristics in Jagir River as drinking water source and to characterize the organic components that could be removed during coagulation. Coagulation is the common water treatment process can be used to remove NOM with FeCl3 coagulant in various dosage. NOM surrogates, including total organic carbon (TOC), ultraviolet absorbance at 254 nm (UV254) and specific UV absorbance (SUVA) were chosen to assess the organic removal. Results of jar test experiments showed that NOM can be removed about 40% of NOM surrogates with 200 mg/L FeCl3. About 60% removal of total organic fraction, which is mainly humic substances, as detected by size exclusion chromatography (SEC).

  16. Utilization of Drinking Water Treatment Slurry to Produce Aluminum Sulfate Coagulant.

    PubMed

    Fouad, Mahmoud M; Razek, Taha M A; Elgendy, Ahmed S

    2017-02-01

      In Egypt, water treatment consumes about 365 000 tons of aluminum sulfate and produces more than 100 million tons of sludge per year. The common disposal system of sludge in Egypt is to discharge it into natural waterways. Toxicity of aluminum, environmental regulations and costs of chemicals used in water treatment and sludge treatment processes led to an evaluation of coagulant recovery and subsequent reuse. The present work aimed at aluminum recovery from sludge of El-Shiekh Zayd water treatment plant (WTP) to produce aluminum sulfate coagulant. Sludge was characterized and the effect of five variables was tested and the process efficiency was evaluated at different operating conditions. Maximum recovery is 94.2% at acid concentration 1.5 N, sludge weight 5 g, mixing speed 60 rpm, temperature 60 °C and leaching time 40 min. Then optimum conditions were applied to get maximum recovery for aluminum sulfate and compared to commercial coagulant on raw water of El-Shiekh Zayd (WTP).

  17. Comparison of coagulation, ozone and ferrate treatment processes for color, COD and toxicity removal from complex textile wastewater.

    PubMed

    Malik, Sameena N; Ghosh, Prakash C; Vaidya, Atul N; Waindeskar, Vishal; Das, Sera; Mudliar, Sandeep N

    2017-09-01

    In this study, the comparative performance of coagulation, ozone, coagulation + ozone + coagulation and potassium ferrate processes to remove chemical oxygen demand (COD), color, and toxicity from a highly polluted textile wastewater were evaluated. Experimental results showed that ferrate alone had no effect on COD, color and toxicity removal. Whereas, in combination with FeSO 4 , it has shown the highest removal efficiency of 96.5%, 83% and 75% for respective parameters at the optimal dose of 40 mgL -1 + 3 ml FeSO 4 (1 M) in comparison with other processes. A seed germination test using seeds of Spinach (Spinacia oleracea) also indicated that ferrate was more effective in removing toxicity from contaminated textile wastewater. Potassium ferrate also produces less sludge with maximum contaminant removal, thereby making the process more economically feasible. Fourier transform infrared spectroscopy (FTIR) analysis also shows the cleavage of the chromophore group and degradation of textile wastewater during chemical and oxidation treatment processes.

  18. A retrospective discussion of the prognostic value of combining prothrombin time(PT) and fibrinogen(Fbg) in patients with Hepatocellular carcinoma.

    PubMed

    Wang, Xue-Ping; Mao, Min-Jie; He, Zhong-Lian; Zhang, Lin; Chi, Pei-Dong; Su, Jia-Rui; Dai, Shu-Qin; Liu, Wan-Li

    2017-01-01

    Aims: The levels of coagulation system tests have been studied in various cancers. In this study, our aim is to evaluate the prognostic value of pretreatment plasma coagulation tests in hepatocellular carcinoma (HCC) patients. Patient and methods: A retrospective study was performed in 539 patients with HCC, and follow-up period was at least 60 months until recurrence or death. The prognostic significance of coagulation system tests (prothrombin time, activated partial thromboplastin time, thrombin time, fibrinogen) were determined by univariate and multivariate Cox hazard models. Then, according to the results of the multivariate analyses, we proposed the coagulation-Based Stage, which combined the independent risk factors (prothrombin time and fibrinogen). Results: Coagulation system tests including prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fbg) were analyzed. Patients with prolonged PT (≥12.1 sec) levels had significantly poor overall survival (OS) and disease-free survival (DFS), not only in the entire cohort (HR: 1.661, 95%CI: 1.125-2.451, p= 0.011 vs. HR: 1.660, 95%CI: 1.125-2.451, p= 0.011), but also in the subgroups stratified by pathological stage (stage I-II and stage III-IV). Additionally, high Fbg (≥2.83 g/L) levels experienced significantly decreased OS and DFS (HR: 2.158, 95%CI: 1.427-3.263, p< 0.001 vs. HR: 2.161, 95%CI: 1.429-3.267, p< 0.001), not only in the entire cohort but also in the subgroups stratified by pathological stage (stage I-II and stage III-IV). All the patients were then stratified (based on combined PT and Fbg) into three groups, The OS for HCC patients were (41.37±17.76), (31.83±19.84) and (18.68±18.41) months, and the DFS for HCC patients were (41.15±17.88), (31.65±19.81) and (18.66±18.39) months. Conclusions: Our findings suggest that the combination of plasma PT and Fbg levels should be evaluated as the valuable predictor of survival in patients with HCC.

  19. Epsilon aminocaproic acid reduces blood transfusion and improves the coagulation test after pediatric open-heart surgery: a meta-analysis of 5 clinical trials

    PubMed Central

    Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan

    2015-01-01

    Background: Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. Methods: A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Results: Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P < 0.0001), and platelet concentrate (MD: -10.66; 95% CI: -18.45 to -2.87; P = 0.007), and had a lower re-exploration rate (RR: 0.46; 95% CI: 0.23 to 0.92; P = 0.03). Prophylactic EACA also improved coagulation tests 6 hours after open-heart surgery. Conclusions: Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the prevention of postoperative blood transfusion following pediatric cardiac surgery. PMID:26339364

  20. Laboratory measurement of the anticoagulant activity of the non-vitamin K oral anticoagulants.

    PubMed

    Cuker, Adam; Siegal, Deborah M; Crowther, Mark A; Garcia, David A

    2014-09-16

    Non-vitamin K oral anticoagulants (NOACs) do not require routine laboratory monitoring. However, laboratory measurement may be desirable in special situations and populations. This study's objective was to systematically review and summarize current evidence regarding laboratory measurement of the anticoagulant activity of dabigatran, rivaroxaban, and apixaban. We searched PubMed and Web of Science for studies that reported a relationship between drug levels of dabigatran, rivaroxaban, and apixaban and coagulation assay results. Study quality was evaluated using QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies 2). We identified 17 eligible studies for dabigatran, 15 for rivaroxaban, and 4 for apixaban. For dabigatran, a normal thrombin time excludes clinically relevant drug concentrations. The activated partial thromboplastin time (APTT) and prothrombin time (PT) are less sensitive and may be normal at trough drug levels. The dilute thrombin time (R(2) = 0.92 to 0.99) and ecarin-based assays (R(2) = 0.92 to 1.00) show excellent linearity across on-therapy drug concentrations and may be used for drug quantification. For rivaroxaban and apixaban, anti-Xa activity is linear (R(2) = 0.89 to 1.00) over a wide range of drug levels and may be used for drug quantification. Undetectable anti-Xa activity likely excludes clinically relevant drug concentrations. The PT is less sensitive (especially for apixaban); a normal PT may not exclude clinically relevant levels. The APTT demonstrates insufficient sensitivity and linearity for quantification. Dabigatran, rivaroxaban, and apixaban exhibit variable effects on coagulation assays. Understanding these effects facilitates interpretation of test results in NOAC-treated patients. More information on the relationship between drug levels and clinical outcomes is needed. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  1. Intraoperative care for aortic surgery using circulatory arrest

    PubMed Central

    Fernández Del Valle, David; González Alvarez, Adrián; Pérez-Lozano, Blanca

    2017-01-01

    The total circulatory arrest (CA) is necessary to achieve optimal surgical conditions in certain aortic pathologies, especially in those affecting the ascending aorta and aortic arch. During this procedure it is necessary to protect all the organs of ischemia, especially those of the central nervous system and for this purpose several strategies have been developed. The first and most important protective method is systemic hypothermia. The degree of hypothermia and the route of application have been evolving and currently tend to use moderate hypothermia (MH) (20.1–28 °C) associated with unilateral or bilateral selective cerebral perfusion methods. In this way the neurological results are better, the interval of security is greater and the times of extracorporeal circulation are smaller. Even so, it is necessary to take into account that there is the possibility of ischemia in the lower part of the body, especially of the abdominal viscera and the spinal cord, therefore the time of circulatory stop should be limited and not to exceed 80 minutes. Evidence of possible neurological drug protection is very weak and only mannitol, magnesium, and statins can produce some benefit. Inhalational anesthetics and some intravenous seem to have advantages, but more studies would be needed to test their long-term benefit. Other important parameters to be monitored during these procedures are blood glucose, anemia and coagulation disorders and acid-base balance. The recommended monitoring is common in complex cardiovascular procedures and it is of special importance the neurological monitoring that can be performed with several techniques, although currently the most used are Bispectral Index (BIS) and Near-Infrared Spectroscopy (NIRS). It is also essential to monitor the temperature routinely at the nasopharyngeal and bladder level and it is important to control coagulation with rotational thromboelastometry (ROTEM). PMID:28616347

  2. Three cases of congenital dysfibrinogenemia in unrelated Chinese families: heterozygous missense mutation in fibrinogen alpha chain Argl6His

    PubMed Central

    Luo, Meiling; Deng, Donghong; Xiang, Liqun; Cheng, Peng; Liao, Lin; Deng, Xuelian; Yan, Jie; Lin, Faquan

    2016-01-01

    Abstract Congenital dysfibrinogenemia (CD) is a qualitative fibrinogen disorder caused by an abnormal fibrinogen molecule structure, leading to dysfunctional blood coagulation. This study describes 3 cases of dysfibrinogenemia identified in the unrelated Chinese pedigrees. Routine coagulation screening tests were performed on the probands and their families. The antigens and functionality of fibrinogen was measured using an immunoturbidimetry assay and the Clauss method, respectively. To identify the genetic mutation responsible for these dysfibrinogens, genomic DNA extracted from the blood was analyzed using PCR amplification and direct sequencing. The presence of the mutant chains was determined using matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectroscopy. Purified plasma fibrinogen of 3 probands was analyzed using SDS–PAGE, fibrinogen clottability, fibrin polymerization, fibrinopeptide release, and scanning electron microscopy (SEM). The 3 probands had a long thrombin time. Levels of functional fibrinogen were found to be very low, while the fibrinogen antigen was within the normal range. DNA sequencing revealed a heterozygous Arg16His substitution in the fibrinogen Aα chain (FGA). The mutant chains were found to be expressed using MALDI-TOF mass spectroscopy. SDS–PAGE did not reveal any difference in the molecular weights of 3 polypeptide chains between normal and abnormal fibrinogens. Fibrinogen clottability showed a slower fibrin clot formation than the healthy control. Fibrin polymerization, after addition of thrombin, showed a prolonged lag phase and decreased final turbidity. The kinetics of fibrinopeptides release revealed a decreased amount of the released fibrinopeptide A. SEM of the patient's fibrin clot was found to be abnormal. Results indicate that the 3 probands with dysfibrinogenemia were caused by mutations of Aα chain Arg16His. Mutation of this fibrinogen induced dysfunction of plasma fibrinogen. PMID:27684817

  3. Incidence & prognosis of acute kidney injury in individuals of snakebite in a tertiary care hospital in India.

    PubMed

    Pulimaddi, Ramulu; Parveda, Amruth Rao; Brahmanpally, Balkishan; Kalakanda, Paul Marx; Ramakrishna, K; Chinnapaka, Venkata Ramana Devi

    2017-12-01

    The snakebites are considered to be an occupational hazard in agriculture workers and the snake handlers, resulting in a considerable morbidity, mortality and economical implications. This study was conducted to determine the incidence, clinical presentation, renal injury and clinical outcome in snakebite victims who developed acute kidney injury (AKI). This hospital-based prospective, observational study was done on 100 cases who were admitted for the management of snakebite and found to develop AKI in a tertiary care hospital at Hyderabad, India. Renal function tests, complete blood picture, urine routine examination, ultrasound examination of abdomen and coagulation profile were done and the prognosis was assessed by noting recovery, mortality, morbidity and/or progress to chronic stage. A total of 100 patients with a mean age of 43.80±12.63 yr (range 18-70); 62 males and 38 females were studied. All had bites on lower limbs. A total of 86 patients arrived in the hospital within 24 h, and 14 arrived after 24 h. Oliguria was found in 60, bleeding tendencies in 64, haemodynamic instability noted - tachycardia in 86. Systolic blood pressure (BP) was <120 mm Hg in 68 and BP was not recordable in four patients. Twelve patients were in stage III kidney disease and needed haemodialysis. Of the 100 cases of snakebite-induced acute kidney failure, 86 recovered and six died. On follow up, after six months eight patients developed chronic kidney failure. A cascade of events tends to occur in severe haemotoxic envenomation such as bleeding disorders, hypotension/circulatory shock, intravascular haemolysis, disseminated intravascular coagulation and acute respiratory disease syndrome (ARDS). The findings of this study showed that early hospitalization, quick antisnake venom administration and adequate supporting care provided promising results.

  4. Acquired antiprothrombin antibodies: an unusual cause of bleeding.

    PubMed

    Carvalho, Cristiana; Viveiro, Carolina; Maia, Paulo; Rezende, Teresa

    2013-01-07

    Acquired inhibitors of coagulation causing bleeding manifestations are rare in children. They emerge, normally in the context of autoimmune diseases or drug ingestion, but transient and self-limiting cases can occur after viral infection. We describe, an otherwise healthy, 7-year-old girl who had gingival bleeding after a tooth extraction. The prothrombin time (PT) and the activated partial thromboplastin time (APTT) were both prolonged with evidence of an immediate acting inhibitor (lupic anticoagulant). Further coagulation studies demonstrated prothrombin (FII) deficiency and prothrombin directed (FII) antibodies. The serological tests to detect an underlying autoimmune disease were all negative. The coagulation studies normalised alongside the disappearance of the antibody. This article presents lupus anticoagulant hypoprothrombinaemia syndrome (LAHS) as a rare case of acquired bleeding diathesis in childhood.

  5. Comparison of two blood sampling techniques for the determination of coagulation parameters in the horse: Jugular venipuncture and indwelling intravenous catheter.

    PubMed

    Mackenzie, C J; McGowan, C M; Pinchbeck, G; Carslake, H B

    2018-05-01

    Evaluation of coagulation status is an important component of critical care. Ongoing monitoring of coagulation status in hospitalised horses has previously been via serial venipuncture due to concerns that sampling directly from the intravenous catheter (IVC) may alter the accuracy of the results. Adverse effects such as patient anxiety and trauma to the sampled vessel could be avoided by the use of an indwelling IVC for repeat blood sampling. To compare coagulation parameters from blood obtained by jugular venipuncture with IVC sampling in critically ill horses. Prospective observational study. A single set of paired blood samples were obtained from horses (n = 55) admitted to an intensive care unit by direct jugular venipuncture and, following removal of a presample, via an indwelling IVC. The following coagulation parameters were measured on venipuncture and IVC samples: whole blood prothrombin time (PT), fresh plasma PT and activated partial thromboplastin time (aPTT) and stored plasma antithrombin activity (AT) and fibrinogen concentration. D-dimer concentration was also measured in some horses (n = 22). Comparison of venipuncture and IVC results was performed using Lin's concordance correlation coefficient. Agreement between paired results was assessed using Bland Altman analysis. Correlation was substantial and agreement was good between sample methods for all parameters except AT and D-dimers. Each coagulation parameter was tested using only one assay. Sampling was limited to a convenience sample and timing of sample collection was not standardised in relation to when the catheter was flushed with heparinised saline. With the exception of AT and D-dimers, coagulation parameters measured on blood samples obtained via an IVC have clinically equivalent values to those obtained by jugular venipuncture. © 2017 EVJ Ltd.

  6. Honey Bee Venom (Apis mellifera) Contains Anticoagulation Factors and Increases the Blood-clotting Time.

    PubMed

    Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi

    2015-12-01

    Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro.

  7. [The blood coagulation system and microcirculatory disorders in ixodid tick-borne borreliosis caused by Borrelia miyamotoi].

    PubMed

    Platonov, A E; Sarksyan, D S; Karan, L S; Shipulin, G A; Gordygina, E V; Malinin, O V; Maleev, V V

    2015-01-01

    To study blood coagulation and microcirculatory disorders as a possible cause of transient dysfunctions of organs (the kidney, liver, heart, lung, etc.) in patients with ixodid tick-borne borreliosis caused by Borrelia miyamotoi (Bmt). SUBJECTS AND METHODS; Twenty-four patients with Lyme disease (LD) and 28 Bmt patients treated at Izhevsk City Hospital (Udmurtia) were examined in the study. Platelet counts and the presence of D-dimers were determined; activated partial thromboplastin time, prothrombin time, thrombin time, fibrinogen and antithrombin III levels, and Factor XIIa-dependent fibrin clot lysis time were measured. Slit lamp microscopy of the conjunctiva was. also carried out. Results. Platelet counts'were less than 150,000 per pL of blood in 43% of the Bmt patients. All the Bmt patients had at least one abnormal coagulation parameter of the eight ones that were tested; 64% of them had marked coagulation disorders with three or more abnormal laboratory findings. In contrast, all the eight parameters were normal in 71% of the LD patients. The other seven LD patients had only one or two abnormal coagulation parameters (p < 0.001 in comparison with Bmt patients). Microscopic examination of eye capillary blood flow revealed pathological findings that included aggregates of erythrocytes and obstructed and/or sinuous capillaries in 22 (79%) of the Bmt patients, but none of the LD patients. A total of 14 Bmt patients had both coagulation and microcirculatory abnormalities. Eleven of them also had transient signs of organ dysfunction. As far as Borrelia secrete no known toxins, we hypothesized that uncovered disorders of blood coagulation and microcirculation in Bmt patients may contribute to organ dysfunction.

  8. Minimizing residual aluminum concentration in treated water by tailoring properties of polyaluminum coagulants.

    PubMed

    Kimura, Masaoki; Matsui, Yoshihiko; Kondo, Kenta; Ishikawa, Tairyo B; Matsushita, Taku; Shirasaki, Nobutaka

    2013-04-15

    Aluminum coagulants are widely used in water treatment plants to remove turbidity and dissolved substances. However, because high aluminum concentrations in treated water are associated with increased turbidity and because aluminum exerts undeniable human health effects, its concentration should be controlled in water treatment plants, especially in plants that use aluminum coagulants. In this study, the effect of polyaluminum chloride (PACl) coagulant characteristics on dissolved residual aluminum concentrations after coagulation and filtration was investigated. The dissolved residual aluminum concentrations at a given coagulation pH differed among the PACls tested. Very-high-basicity PACl yielded low dissolved residual aluminum concentrations and higher natural organic matter (NOM) removal. The low residual aluminum concentrations were related to the low content of monomeric aluminum (Ala) in the PACl. Polymeric (Alb)/colloidal (Alc) ratio in PACl did not greatly influence residual aluminum concentration. The presence of sulfate in PACl contributed to lower residual aluminum concentration only when coagulation was performed at around pH 6.5 or lower. At a wide pH range (6.5-8.5), residual aluminum concentrations <0.02 mg/L were attained by tailoring PACl properties (Ala percentage ≤0.5%, basicity ≥85%). The dissolved residual aluminum concentrations did not increase with increasing the dosage of high-basicity PACl, but did increase with increasing the dosage of normal-basicity PACl. We inferred that increasing the basicity of PACl afforded lower dissolved residual aluminum concentrations partly because the high-basicity PACls could have a small percentage of Ala, which tends to form soluble aluminum-NOM complexes with molecular weights of 100 kDa-0.45 μm. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Honey Bee Venom (Apis mellifera) Contains Anticoagulation Factors and Increases the Blood-clotting Time

    PubMed Central

    Zolfagharian, Hossein; Mohajeri, Mohammad; Babaie, Mahdi

    2015-01-01

    Objectives: Bee venom (BV) is a complex mixture of proteins and contains proteins such as phospholipase and melittin, which have an effect on blood clotting and blood clots. The mechanism of action of honey bee venom (HBV, Apis mellifera) on human plasma proteins and its anti-thrombotic effect were studied. The purpose of this study was to investigate the anti-coagulation effect of BV and its effects on blood coagulation and purification. Methods: Crude venom obtained from Apis mellifera was selected. The anti-coagulation factor of the crude venom from this species was purified by using gel filtration chromatography (sephadex G-50), and the molecular weights of the anti-coagulants in this venom estimated by using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Blood samples were obtained from 10 rabbits, and the prothrombin time (PT) and the partial thromboplastin time (PTT) tests were conducted. The approximate lethal dose (LD) values of BV were determined. Results: Crude BV increased the blood clotting time. For BV concentrations from 1 to 4 mg/mL, clotting was not observed even at more than 300 seconds, standard deviations (SDs) = ± 0.71; however, clotting was observed in the control group 13.8 s, SDs = ± 0.52. Thus, BV can be considered as containing anti-coagulation factors. Crude BV is composed 4 protein bands with molecular weights of 3, 15, 20 and 41 kilodalton (kDa), respectively. The LD50 of the crude BV was found to be 177.8 μg/mouse. Conclusion: BV contains anti-coagulation factors. The fraction extracted from the Iranian bees contains proteins that are similar to anti-coagulation proteins, such as phospholipase A2 (PLA2) and melittin, and that can increase the blood clotting times in vitro. PMID:26998384

  10. Influence of Acute Normobaric Hypoxia on Hemostasis in Volunteers with and without Acute Mountain Sickness

    PubMed Central

    Schaber, Marc; Leichtfried, Veronika; Fries, Dietmar; Wille, Maria; Gatterer, Hannes; Faulhaber, Martin; Würtinger, Philipp; Schobersberger, Wolfgang

    2015-01-01

    Introduction. The aim of the present study was to investigate whether a 12-hour exposure in a normobaric hypoxic chamber would induce changes in the hemostatic system and a procoagulant state in volunteers suffering from acute mountain sickness (AMS) and healthy controls. Materials and Methods. 37 healthy participants were passively exposed to 12.6% FiO2 (simulated altitude hypoxia of 4,500 m). AMS development was investigated by the Lake Louise Score (LLS). Prothrombin time, activated partial thromboplastin time, fibrinogen, and platelet count were measured and specific methods (i.e., thromboelastometry and a thrombin generation test) were used. Results. AMS prevalence was 62.2% (LLS cut off of 3). For the whole group, paired sample t-tests showed significant increase in the maximal concentration of generated thrombin. ROTEM measurements revealed a significant shortening of coagulation time and an increase of maximal clot firmness (InTEM test). A significant increase in maximum clot firmness could be shown (FibTEM test). Conclusions. All significant changes in coagulation parameters after exposure remained within normal reference ranges. No differences with regard to measured parameters of the hemostatic system between AMS-positive and -negative subjects were observed. Therefore, the hypothesis of the acute activation of coagulation by hypoxia can be rejected. PMID:26451374

  11. Influence of Acute Normobaric Hypoxia on Hemostasis in Volunteers with and without Acute Mountain Sickness.

    PubMed

    Schaber, Marc; Leichtfried, Veronika; Fries, Dietmar; Wille, Maria; Gatterer, Hannes; Faulhaber, Martin; Würtinger, Philipp; Schobersberger, Wolfgang

    2015-01-01

    The aim of the present study was to investigate whether a 12-hour exposure in a normobaric hypoxic chamber would induce changes in the hemostatic system and a procoagulant state in volunteers suffering from acute mountain sickness (AMS) and healthy controls. 37 healthy participants were passively exposed to 12.6% FiO2 (simulated altitude hypoxia of 4,500 m). AMS development was investigated by the Lake Louise Score (LLS). Prothrombin time, activated partial thromboplastin time, fibrinogen, and platelet count were measured and specific methods (i.e., thromboelastometry and a thrombin generation test) were used. AMS prevalence was 62.2% (LLS cut off of 3). For the whole group, paired sample t-tests showed significant increase in the maximal concentration of generated thrombin. ROTEM measurements revealed a significant shortening of coagulation time and an increase of maximal clot firmness (InTEM test). A significant increase in maximum clot firmness could be shown (FibTEM test). All significant changes in coagulation parameters after exposure remained within normal reference ranges. No differences with regard to measured parameters of the hemostatic system between AMS-positive and -negative subjects were observed. Therefore, the hypothesis of the acute activation of coagulation by hypoxia can be rejected.

  12. Wetlands receiving water treated with coagulants improve water quality by removing dissolved organic carbon and disinfection byproduct precursors.

    PubMed

    Hansen, Angela M; Kraus, Tamara E C; Bachand, Sandra M; Horwath, William R; Bachand, Philip A M

    2018-05-01

    Constructed wetlands are used worldwide to improve water quality while also providing critical wetland habitat. However, wetlands have the potential to negatively impact drinking water quality by exporting dissolved organic carbon (DOC) that upon disinfection can form disinfection byproducts (DBPs) like trihalomethanes (THMs) and haloacetic acids (HAAs). We used a replicated field-scale study located on organic rich soils in California's Sacramento-San Joaquin Delta to test whether constructed flow-through wetlands which receive water high in DOC that is treated with either iron- or aluminum-based coagulants can improve water quality with respect to DBP formation. Coagulation alone removed DOC (66-77%) and THM (67-70%) precursors, and was even more effective at removing HAA precursors (77-90%). Passage of water through the wetlands increased DOC concentrations (1.5-7.5mgL -1 ), particularly during the warmer summer months, thereby reversing some of the benefits from coagulant addition. Despite this addition, water exiting the wetlands treated with coagulants had lower DOC and DBP precursor concentrations relative to untreated source water. Benefits of the coagulation-wetland systems were greatest during the winter months (approx. 50-70% reduction in DOC and DBP precursor concentrations) when inflow water DOC concentrations were higher and wetland DOC production was lower. Optical properties suggest DOC in this system is predominantly comprised of high molecular weight, aromatic compounds, likely derived from degraded peat soils. Published by Elsevier B.V.

  13. Plasmodium falciparum-infected erythrocytes induce Tissue Factor expression in endothelial cells and support the assembly of multimolecular coagulation complexes

    PubMed Central

    Francischetti, Ivo MB; Seydel, Karl B; Monteiro, Robson Q; Whitten, Richard O; Erexson, Cindy R; Noronha, Almério LL; Ostera, Graciela R.; Kamiza, Steve B; Molyneux, Malcolm E; Ward, Jerrold M; Taylor, Terrie E

    2010-01-01

    Summary Background Plasmodium falciparum malaria infects 300–500 million people every year causing 1–2 million deaths annually. Evidence of a coagulation disorder, activation of endothelial cells (EC) and increase in inflammatory cytokines are often present in malaria. Objectives We have asked whether parasitized red blood cells (pRBC) interaction with EC induces Tissue Factor expression in vitro and in vivo. The potential of phosphatidylserine-containing pRBC to support the assembly of blood coagulation complexes was also investigated. Results We demonstrate that mature forms of pRBC induce functional expression of tissue factor (TF) by endothelial cells (EC) in vitro with productive assembly of the extrinsic Xnase complex and initiation of the coagulation cascade. Late stage pRBC also support the prothrombinase and intrinsic Xnase complex formation in vitro, and may function as activated platelets in the amplification phase of the blood coagulation. Notably, postmortem brain sections obtained from P. falciparum-infected children who died from Cerebral Malaria and other causes display a consistent staining for TF in the EC. Conclusions These findings place TF expression by endothelium and the amplification of the coagulation cascade by pRBC and/or activated platelets as potentially critical steps in the pathogenesis of malaria. Furthermore, it may allow investigators to test other therapeutic alternatives targeting TF or modulators of EC function in the treatment of malaria and/or its complications. PMID:17002660

  14. Operation and performance of the Ciba-Corning 512 coagulation monitor during parabolic flight

    NASA Technical Reports Server (NTRS)

    Gocke, Robyn; Lloyd, Charles W.; Greenthaner, Nancy K.

    1991-01-01

    The goal was to assess the functionality and evaluate the procedures and operations required to operate the Ciba-Corning 512 Coagulation Monitor during parabolic flight. This monitor determines the clotting characteristics of blood. The analyzer operates by laser detection of the cessation of blood flow in a capillary channel within a test cartridge. Test simulator results were excellent for both pre-and post-flight. In-flight results were not obtained due to the warm-up time required for the simulator. Since this is an electronic function only, the expected results on the simulator would be the same in zero-g.

  15. Extended indications for percutaneous tracheostomy.

    PubMed

    Ben Nun, Alon; Altman, Eduard; Best, Lael Anson

    2005-10-01

    In recent years, percutaneous tracheostomy has become a routine practice in many hospitals. In the early publications, most authors considered adverse conditions such as short, fat neck or obesity as relative contraindications whereas cervical injury, coagulopathy, and emergency were regarded as absolute contraindications. More recently, several reports demonstrated the feasibility of percutaneous tracheostomy in patients with some of these contraindications. The aim of this study is to determine the safety and efficacy of percutaneous tracheostomy in conditions commonly referred to as contraindications. Between June 2000 and July 2001, 157 consecutive percutaneous tracheostomy procedures were performed on 154 critically ill adult patients in the general intensive care unit of a major tertiary care facility. The Griggs technique and Portex set were used at the bedside. All procedures were performed by staff thoracic surgeons and anesthesiologists experienced with the technique. Anatomical conditions, presence of coagulopathy and anti-coagulation therapy, demographics, and complication rates were recorded. Five of 157 procedures (154 patients owing to three repeat tracheostomies) had complications. In patients with normal anatomical conditions and coagulation profiles, there was one case of bleeding (50 cc to 120 cc) and one case of mild cellulitis around the stoma. In patients with adverse conditions, there was one case of bleeding (50 cc to 120 cc) and two cases of minor bleeding (< 50 cc). Patients with adverse conditions had a low complication rate similar to patients with normal conditions. For this reason, we believe that percutaneous tracheostomy is indicated in patients with short, fat neck; inability to perform neck extension; enlarged isthmus of thyroid; previous tracheostomy; or coagulopathy and anti-coagulation therapy.

  16. Comparative assessment of coagulation changes induced by two different types of heart-lung machine.

    PubMed

    Rahe-Meyer, Niels; Solomon, Cristina; Tokuno, Marie-Louise; Winterhalter, Michael; Shrestha, Malakh; Hahn, Andreas; Tanaka, Kenichi

    2010-01-01

    The cardiopulmonary bypass (CPB) used in heart surgery has a deleterious effect on hemostasis. The aim of our study was to assess by means of standard laboratory and point-of-care methods changes induced by CPB in coagulation parameters, particularly in platelet function, and to determine whether these changes differ depending on the type of heart-lung machine (HLM) used: minimal extracorporeal circulation system (MECC) and standard HLM. The study enrolled 88 patients scheduled for coronary artery bypass surgery performed on pump. Forty-four interventions were performed with MECC and 44 with standard HLM. Blood was sampled preoperatively, after 30 min on CPB, after weaning from CPB, and 24 h postoperatively. Coagulation and platelet function were assessed using multiple electrode aggregometry (MEA), rotation thromboelastometry, as well as standard laboratory tests. Rotation thromboelastometry and standard laboratory reflected significantly impaired hemostasis after weaning from CPB but no significant differences between the two groups at different time points. Aggregation decreased significantly in both groups as early as 30 min after the institution of CPB (P < 0.05, Mann-Whitney U-test) and recovered within the first 24 h postoperatively, without reaching the preoperative level. Intraoperatively, aggregometry values reflected a significantly more severe reduction of platelet function in standard HLM group than in the MECC group (P < 0.01, ProcMixed test). Our findings suggest that MEA and thromboelastometry reflect impairment of coagulation in cardiac surgery performed on different types of HLM and that platelet function is less affected by MECC than by standard HLM.

  17. Removal of Mycobacterium avium subspecies hominissuis (MAH) from drinking water by coagulation, flocculation and sedimentation processes.

    PubMed

    Wong, E A; Shin, G-A

    2015-03-01

    There has been a growing concern over human exposure to Mycobacterium avium subspecies hominissuis (MAH) through drinking water due to its ubiquitous presence in natural waters and remarkable resistance to both chemical and physical disinfectants in drinking water treatment processes. However, little is known about the effectiveness of physico-chemical water treatment processes to remove MAH. Therefore, we determined the removal of MAH by alum coagulation, flocculation and sedimentation processes in optimized drinking water treatment conditions using standard jar test equipment. Contrary to the prevailing hypothesis, the results of this study show that removal of MAH by coagulation, flocculation and sedimentation processes was only moderate (approx. 0.65 log10) under low turbidity treatment conditions and the removal of MAH was actually lower than that of Escherichia coli (reference bacterium) in all the waters tested. Overall, the results of this study suggested that coagulation, flocculation and sedimentation processes may not be a reliable treatment option for removing MAH, and more efforts to find an effective control measures against MAH should be made to reduce the risk of MAH infection from drinking water. Despite a growing concern over human exposure to Mycobacterium avium subspecies hominissuis (MAH) through drinking water and its remarkable resistance to water disinfectants, little is known about the effectiveness of physico-chemical water treatment processes to remove MAH. Contrary to the prevailing hypothesis, the results of this study suggest that coagulation, flocculation and sedimentation processes may not be a reliable treatment option for MAH removal. As these processes have been the last remaining conventional drinking water treatment processes that might be effective against MAH, more efforts should be urgently made to find an effective control measures against this important waterborne pathogen. © 2014 The Society for Applied Microbiology.

  18. Internal Quality Control Practices in Coagulation Laboratories: recommendations based on a patterns-of-practice survey.

    PubMed

    McFarlane, A; Aslan, B; Raby, A; Moffat, K A; Selby, R; Padmore, R

    2015-12-01

    Internal quality control (IQC) procedures are crucial for ensuring accurate patient test results. The IQMH Centre for Proficiency Testing conducted a web-based survey to gather information on the current IQC practices in coagulation testing. A questionnaire was distributed to 174 Ontario laboratories licensed to perform prothrombin time (PT) and activated partial thromboplastin time (APTT). All laboratories reported using two levels of commercial QC (CQC); 12% incorporate pooled patient plasma into their IQC program; >68% run CQC at the beginning of each shift; 56% following maintenance, with reagent changes, during a shift, or with every repeat sample; 6% only run CQC at the beginning of the day and 25% when the instruments have been idle for a defined period of time. IQC run frequency was determined by manufacturer recommendations (71%) but also influenced by the stability of test (27%), clinical impact of an incorrect test result (25%), and sample's batch number (10%). IQC was monitored using preset limits based on standard deviation (66%), precision goals (46%), or allowable performance limits (36%). 95% use multirules. Failure actions include repeating the IQC (90%) and reporting patient results; if repeat passes, 42% perform repeat analysis of all patient samples from last acceptable IQC. Variability exists in coagulation IQC practices among Ontario clinical laboratories. The recommendations presented here would be useful in encouraging standardized IQC practices. © 2015 John Wiley & Sons Ltd.

  19. Restoration of water environment contaminated by radioactive cesium released from Fukushima Daiichi NPP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeshita, K.; Takahashi, H.; Jinbo, Y.

    2013-07-01

    In the Fukushima Daiichi NPP Accident, large amounts of volatile radioactive nuclides, such as {sup 131}I, {sup 134}Cs and {sup 137}Cs, were released to the atmosphere and huge areas surrounding the nuclear site were contaminated by the radioactive fallout. In this study, a combined process with a hydrothermal process and a coagulation settling process was proposed for the separation of radioactive Cs from contaminated soil and sewage sludge. The coagulation settling operation uses Prussian Blue (Ferric ferrocyanide) and an inorganic coagulant. The recovery of Cs from sewage sludge sampled at Fukushima city (100.000 Bq/kg) and soil at a nearby villagemore » (55.000 Bq/kg), was tested. About 96% of Cs in the sewage sludge was removed successfully by combining simple hydrothermal decomposition and coagulation settling. However, Cs in the soil was not removed sufficiently by the combined process (Cs removal is only 56%). The hydrothermal decomposition with blasting was carried out. The Cs removal from the soil was increased to 85%. When these operations were repeated twice, the Cs recovery was over 90%. The combined process with hydrothermal blasting and coagulation settling is applicable to the removal of Cs from highly contaminated soil.« less

  20. Restoration of tensile strength in bark samples of Ficus benjamina due to coagulation of latex during fast self-healing of fissures

    PubMed Central

    Bauer, Georg; Speck, Thomas

    2012-01-01

    Background and Aims The functions of plant latex have been discussed for a long time. Today, many studies support a defence mechanism as being its main function. A role as a self-healing mechanism was never attributed to the coagulation of latex. In this study we quantified the contribution of the coagulation of Ficus benjamina (weeping fig) latex to a restoration of the mechanical properties of the bark after external lesions. Methods Tensile tests of F. benjamina bark were conducted either immediately after injury or at various latency times after injury. Key Results A significant increase in the tensile strength of bark samples until 30 min after injury was found, and this effect could be attributed to the coagulation of plant latex alone. The tensile strength remains nearly constant until several hours or days after injury. Then, very probably due to other mechanisms such as cell growth and cell proliferation, the tensile strength begins to increase slightly again. Conclusions The coagulation of latex seals lesions and serves as a quick and effective pre-step of subsequent, more effective, long-lasting self-healing mechanisms such as cell growth and proliferation. Thus, a fast self-healing effect can be included in the list of functions of plant latex. PMID:22207613

  1. Restoration of tensile strength in bark samples of Ficus benjamina due to coagulation of latex during fast self-healing of fissures.

    PubMed

    Bauer, Georg; Speck, Thomas

    2012-03-01

    The functions of plant latex have been discussed for a long time. Today, many studies support a defence mechanism as being its main function. A role as a self-healing mechanism was never attributed to the coagulation of latex. In this study we quantified the contribution of the coagulation of Ficus benjamina (weeping fig) latex to a restoration of the mechanical properties of the bark after external lesions. Tensile tests of F. benjamina bark were conducted either immediately after injury or at various latency times after injury. A significant increase in the tensile strength of bark samples until 30 min after injury was found, and this effect could be attributed to the coagulation of plant latex alone. The tensile strength remains nearly constant until several hours or days after injury. Then, very probably due to other mechanisms such as cell growth and cell proliferation, the tensile strength begins to increase slightly again. The coagulation of latex seals lesions and serves as a quick and effective pre-step of subsequent, more effective, long-lasting self-healing mechanisms such as cell growth and proliferation. Thus, a fast self-healing effect can be included in the list of functions of plant latex.

  2. Experimental dosing of wetlands with coagulants removes mercury from surface water and decreases mercury bioaccumulation in fish

    USGS Publications Warehouse

    Ackerman, Joshua T.; Kraus, Tamara E.C.; Fleck, Jacob A.; Krabbenhoft, David P.; Horwarth, William R.; Bachand, Sandra M.; Herzog, Mark; Hartman, Christopher; Bachand, Philip A.M.

    2015-01-01

    Mercury pollution is widespread globally, and strategies for managing mercury contamination in aquatic environments are necessary. We tested whether coagulation with metal-based salts could remove mercury from wetland surface waters and decrease mercury bioaccumulation in fish. In a complete randomized block design, we constructed nine experimental wetlands in California’s Sacramento–San Joaquin Delta, stocked them with mosquitofish (Gambusia affinis), and then continuously applied agricultural drainage water that was either untreated (control), or treated with polyaluminum chloride or ferric sulfate coagulants. Total mercury and methylmercury concentrations in surface waters were decreased by 62% and 63% in polyaluminum chloride treated wetlands and 50% and 76% in ferric sulfate treated wetlands compared to control wetlands. Specifically, following coagulation, mercury was transferred from the filtered fraction of water into the particulate fraction of water which then settled within the wetland. Mosquitofish mercury concentrations were decreased by 35% in ferric sulfate treated wetlands compared to control wetlands. There was no reduction in mosquitofish mercury concentrations within the polyaluminum chloride treated wetlands, which may have been caused by production of bioavailable methylmercury within those wetlands. Coagulation may be an effective management strategy for reducing mercury contamination within wetlands, but further studies should explore potential effects on wetland ecosystems.

  3. Size-Resolved Ultrafine Particle Deposition and Brownian Coagulation from Gasoline Vehicle Exhaust in an Environmental Test Chamber.

    PubMed

    Zhao, Yu; Wang, Fang; Zhao, Jianing

    2015-10-20

    Size-resolved deposition rates and Brownian coagulation of particles between 20 and 900 nm (mobility diameter) were estimated in a well-mixed environmental chamber from a gasoline vehicle exhaust with a total peak particle concentration of 10(5)-10(6) particles/cm(3) at 12.24-25.22 °C. A deposition theory with modified friction velocity and coagulation model was also employed to predict particle concentration decay. Initially during particle decay, approximately 85% or more of the particles had diameters of <100 nm. Particle deposition rates with standard deviations were highly dependent on particle size ranges, and varied from 0.012 ± 0.003 to 0.48 ± 0.02 h(-1). In the experiment, the friction velocity obtained was in the range 1.5-2.5 cm/s. The most explainable fractal dimension and Hamaker constant in coagulation model were 2.5-3 and 20 kT, respectively, and the contribution from coagulation dominated the total particle decay during the first 1 h of decay. It is considered that the modified friction velocity and best fitted fractal dimension and Hamaker constants could be further used to analyze gasoline vehicle exhaust particle dynamics and assess human exposure to vehicle particle pollutants in urban areas, tunnels, and underground parking lots.

  4. The role of leukotoxin (9,10-epoxy-12-octadecenoate) in the genesis of coagulation abnormalities.

    PubMed

    Sugiyama, S; Hayakawa, M; Hanaki, Y; Hieda, N; Asai, J; Ozawa, T

    1988-01-01

    This study was designed to clarify whether or not leukotoxin (9, 10-epoxy-12-octadecenoate), which is biosynthesized by neutrophils, might be involved in the genesis of coagulating abnormalities. Twelve dogs were divided into 2 groups. In the test group (n = 6), 100 mumol/kg of leukotoxin was injected intravenously, and in the control group (n = 6), 100 mumol/kg of linoleate was injected. In each group, a series of blood samples were collected and used for coagulation studies. After the end of the experimental period, a histological study was performed on organs removed from the dogs. In the leukotoxin group, fibrin and fibrinogen degradation products (FDP) was increased time-dependently. Fibrinogen was decreased, and prothrombin time and activated partial thromboplastin time were prolonged in parallel with the increase in FDP. A decrease in number of platelets was also observed. Intravascular coagulation was observed in sections of lung. These data were compatible with a diagnosis of disseminated intravascular coagulation (DIC). No significant changes in these parameters were observed in the linoleate group. Leukotoxin has been confirmed to show antifungal and antibacterial activity, and its production might be a defensive response to infection. Over-production of leukotoxin associated with severe infection might therefore account for infection-induced DIC.

  5. Research of combined adsorption-coagulation process in treating petroleum refinery effluent.

    PubMed

    Wang, Bing; Shui, Yiyu; Ren, Hongyang; He, Min

    2017-02-01

    The petroleum refinery industry generates a significant amount of wastewater that contains a high level of organic matter, which calls for effective and costly treatments. In this research, the effectiveness of the petroleum refinery effluent (PRE) treatment with physicochemical process of combined adsorption and coagulation was evaluated. The effects of initial pH, hydraulic condition , and combined sequence of treatment process, different treating reagent types and dosages on the chemical oxygen demand (COD) removal were investigated. Additionally, the elimination efficiency of pollutant wastewater was monitored by gas chromatography-mass spectrometry (GC-MS), and Fourier transformed infrared (FT-IR) spectrophotometer was adopted to describe the structure of the wastewater. Wooden activated carbon was chosen as adsorbent at the dosage of 10 g/L as a primary treatment, and 1500 mg/L polymeric magnesium ferric sulfate was used in coagulation. Results showed that adsorption and subsequent coagulation displayed the best performance when initial pH was 9 at shear rates (G) of G1 = 65 s -1 and G2 = 20 s -1 , which reached maximal removal rate of COD and total organic carbon GC-MS testing result revealed that adsorption was effective in phenols and iso-alkanes removal, whereas coagulation was good at removing esters and n-alkanes.

  6. Experimental dosing of wetlands with coagulants removes mercury from surface water and decreases mercury bioaccumulation in fish.

    PubMed

    Ackerman, Joshua T; Kraus, Tamara E C; Fleck, Jacob A; Krabbenhoft, David P; Horwath, William R; Bachand, Sandra M; Herzog, Mark P; Hartman, C Alex; Bachand, Philip A M

    2015-05-19

    Mercury pollution is widespread globally, and strategies for managing mercury contamination in aquatic environments are necessary. We tested whether coagulation with metal-based salts could remove mercury from wetland surface waters and decrease mercury bioaccumulation in fish. In a complete randomized block design, we constructed nine experimental wetlands in California's Sacramento-San Joaquin Delta, stocked them with mosquitofish (Gambusia affinis), and then continuously applied agricultural drainage water that was either untreated (control), or treated with polyaluminum chloride or ferric sulfate coagulants. Total mercury and methylmercury concentrations in surface waters were decreased by 62% and 63% in polyaluminum chloride treated wetlands and 50% and 76% in ferric sulfate treated wetlands compared to control wetlands. Specifically, following coagulation, mercury was transferred from the filtered fraction of water into the particulate fraction of water which then settled within the wetland. Mosquitofish mercury concentrations were decreased by 35% in ferric sulfate treated wetlands compared to control wetlands. There was no reduction in mosquitofish mercury concentrations within the polyaluminum chloride treated wetlands, which may have been caused by production of bioavailable methylmercury within those wetlands. Coagulation may be an effective management strategy for reducing mercury contamination within wetlands, but further studies should explore potential effects on wetland ecosystems.

  7. Detection of mild inherited disorders of blood coagulation: current options and personal recommendations.

    PubMed

    Lippi, Giuseppe; Pasalic, Leonardo; Favaloro, Emmanuel J

    2015-08-01

    Although assessment of prior personal and familial bleeding history is an important aspect of the diagnosis of bleeding disorders, patients with mild inherited bleeding disorders are sometimes clinically asymptomatic until presented with a hemostatic challenge. However, bleeding may occur after incursion of trauma or surgery, so detection of these conditions reflects an important facet of clinical and laboratory practice. Mild bleeding disorders may be detected as a result of family studies or following identification of abnormal values in first-line screening tests such as activated partial thromboplastin time, prothrombin time, fibrinogen and global platelet function screen testing, such as the platelet function analyzer. Following determination of abnormal screening tests, subsequent investigation should follow a systematic approach that targets specific diagnostic tests, and including factor assays, full platelet function assays and more extensive specialized hemostasis testing. The current report provides a personal overview on inherited disorders of blood coagulation and their detection.

  8. Point-of-Care Coagulation Tests Monitoring of Direct Oral Anticoagulants and Their Reversal Therapy: State of the Art.

    PubMed

    Iapichino, Giacomo E; Bianchi, Paolo; Ranucci, Marco; Baryshnikova, Ekaterina

    2017-06-01

    Direct oral anticoagulants (DOACs) exert similar anticoagulant effects to vitamin K antagonists and are increasingly used worldwide. Nevertheless, an evidence-based approach to patients receiving DOACs when any unplanned urgent surgery or bleeding (either spontaneous or traumatic) occurs is still missing. In this review, we investigate the role of point-of-care coagulation tests when other, more specific tests are not available. Indeed, thromboelastography and activated clotting time can detect dabigatran-induced coagulopathy, while their accuracy is limited for apixaban and rivaroxaban, mostly in cases of low drug plasma concentrations. These tests can also be used to guide the reversal of DOAC-induced coagulopathy providing a quick, before-and-after picture in case of therapeutic use of hemostatic compounds. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Clinical biochemistry laboratory rejection rates due to various types of preanalytical errors.

    PubMed

    Atay, Aysenur; Demir, Leyla; Cuhadar, Serap; Saglam, Gulcan; Unal, Hulya; Aksun, Saliha; Arslan, Banu; Ozkan, Asuman; Sutcu, Recep

    2014-01-01

    Preanalytical errors, along the process from the beginning of test requests to the admissions of the specimens to the laboratory, cause the rejection of samples. The aim of this study was to better explain the reasons of rejected samples, regarding to their rates in certain test groups in our laboratory. This preliminary study was designed on the rejected samples in one-year period, based on the rates and types of inappropriateness. Test requests and blood samples of clinical chemistry, immunoassay, hematology, glycated hemoglobin, coagulation and erythrocyte sedimentation rate test units were evaluated. Types of inappropriateness were evaluated as follows: improperly labelled samples, hemolysed, clotted specimen, insufficient volume of specimen and total request errors. A total of 5,183,582 test requests from 1,035,743 blood collection tubes were considered. The total rejection rate was 0.65 %. The rejection rate of coagulation group was significantly higher (2.28%) than the other test groups (P < 0.001) including insufficient volume of specimen error rate as 1.38%. Rejection rates of hemolysis, clotted specimen and insufficient volume of sample error were found to be 8%, 24% and 34%, respectively. Total request errors, particularly, for unintelligible requests were 32% of the total for inpatients. The errors were especially attributable to unintelligible requests of inappropriate test requests, improperly labelled samples for inpatients and blood drawing errors especially due to insufficient volume of specimens in a coagulation test group. Further studies should be performed after corrective and preventive actions to detect a possible decrease in rejecting samples.

  10. Importance of fibrinogen in dilutional coagulopathy after neurosurgical procedures: A descriptive study.

    PubMed

    Nair, Shalini; Nair, Bijesh Ravindran; Vidyasagar, Ajay; Joseph, Mathew

    2016-08-01

    The routine management of coagulopathy during surgery involves assessing haemoglobin, prothrombin time (PT), activated partial thromboplastin time (aPTT) and platelets. Correction of these parameters involves administration of blood, fresh frozen plasma and platelet concentrates. The study was aimed at identifying the most common coagulation abnormality during neurosurgical procedures and the treatment of dilutional coagulopathy with blood components. During 2 years period, all adult patients undergoing neurosurgical procedures who were transfused two or more units of red cells were prospectively evaluated for the presence of a coagulopathy. PT, aPTT, platelet count and fibrinogen levels were estimated before starting a component therapy. After assessing PT, aPTT, platelet count and fibrinogen levels following two or more blood transfusions, thirty patients were found to have at least one abnormal parameter that required administration of a blood product. The most common abnormality was a low fibrinogen level, seen in 26 patients; this was the only abnormality in three patients. No patient was found to have an abnormal PT or aPTT without either the fibrinogen concentration or platelet count or both being low. Low fibrinogen concentration was the most common coagulation abnormality found after blood transfusions for neurosurgical procedures.

  11. [Survey on the contamination of microcystin-LR in water supply of Shanghai city].

    PubMed

    Wu, He-yan; Zheng, Li-xing; Su, Jin; Shi, Wei

    2005-03-01

    To study the pollution level of microcystin-LR in water supply of Shanghai city and the removal efficacy for microcystin-LR through routine water treatment technique. High performance liquid chromatogram (HPLC) was applied to determine the concentration of microcystin-LR in source water, water samples after various water treatment procedures and tap water. The concentration of microcystin-LR varied with sampling seasons and sites and reached peak during summer and fall. The maximum of microcystin-LR was 2.38 microg/L in source water. Coagulation plus chlorine disinfection were found to be effective for the removal of microcystin-LR, while the remove rate through filtration was not significant. And it could also be detected in tap water as high as 1.27 microg/L. The source waters of Shanghai city were polluted by cyanobacteria toxins represented by microcystin-LR. The source water in suburb was more polluted. Routine water treatment techniques can not remove the toxins effectively.

  12. Effect of chemical treatment on the acute toxicity of two commercial textile dye carriers.

    PubMed

    Arsian-Alaton, I; Iskender, G; Ozerkan, B; Germirli Babuna, F; Okay, O

    2007-01-01

    In the present experimental study, the effect of chemical treatment (coagulation-flocculation) on the acute toxicity exerted by two commercial dye carriers (called Carrier A and B herein) often used in the textile industry was investigated. Two different test organisms were selected to elucidate the situations in activated sludge treatment systems (activated sludge microorganisms) as well as in receiving water bodies (ultimate marine discharge). According to the results of a comprehensive analysis covering COD removal efficiencies, sludge settling characteristics and operating costs involved in coagulation-flocculation, the optimum treatment conditions were defined as follows; application of 750 mg/L ferrous sulphate at a pH of 9.0 for Carrier A; and application of 550 mg/L ferrous sulphate at a pH of 9.0 for Carrier B. The acute toxicities of both dye carriers towards marine microalgea Phaeodactylum tricornutum could be reduced significantly after being subjected to coagulation-flocculation. Fair toxicity removals (towards heterotrophic mixed bacterial culture accommodated in activated sludge treatment) were obtained with coagulation-flocculation for both of the carriers under investigation.

  13. Temperature-dependent physical properties of egg white for HIFU applications

    NASA Astrophysics Data System (ADS)

    Liu, Yunbo; Maruvada, Subha; Herman, Bruce A.; Harris, Gerald R.

    2012-10-01

    Because egg white denatures at elevated temperature due to its protein content, it has the potential for use as a blood coagulation surrogate in pre-clinical evaluations of thermal therapy procedures such as high intensity focused ultrasound (HIFU) surgery. We therefore have measured the relevant physical properties of egg white, including coagulation temperature, frequency-dependent attenuation, sound speed, viscosity, and thermal properties, as a function of temperature (20 - 95°C). Thermal coagulation and attenuation (5-12 MHz) of cow blood, pig blood, and human blood also were assessed and compared with egg white. For a 30 s thermal exposure, both egg white and blood samples started to denature at 65°C and coagulate into an elastic gel at 85°C. The temperature-dependent parameters were found to be similar to that of the blood samples. For example, the attenuation of egg white ranged from 0.23f1.09 to 2.7f0.5 dB/cm over the 20°C - 95°C range. These results suggest that egg white would make a useful blood mimic for bench testing of therapeutic ultrasound devices.

  14. Coagulation phenotypes in septic shock as evaluated by calibrated automated thrombography.

    PubMed

    Perrin, Julien; Charron, Cyril; François, Jean-Hugues; Cramer-Bordé, Elisabeth; Lévy, Bruno; Borgel, Delphine; Vieillard-Baron, Antoine

    2015-01-01

    Sepsis induces alterations of coagulation suggesting both hypercoagulable or hypocoagulable features. The result of their combination remains unknown, making it difficult to predict whether one prevails over the other. Thrombin generation tests (TGTs) stand as an interesting tool to establish an integrative phenotype of coagulation. It has been reported that septic patients display a hypocoagulable trait using TGT. However, protein C (PC) system response was not evaluated. We aimed at describing the thrombin generation profile in patients with septic shock under conditions that are sensitive to PC system to evaluate the net results of coagulation abnormalities and to determine whether hypercoagulable or hypocoagulable traits coexist within a given individual. Thrombin generation was studied in plasma from patients presenting with septic shock at diagnosis and 6 h after a conventional therapeutic management using calibrated automated thrombography with or without thrombomodulin (TM) addition. Patients exhibit clear alterations of TGT that present as both consumption-related hypocoagulability (evidenced without TM addition) but also hypercoagulability by decreased sensitivity to the PC system evidenced with TM addition. No difference could be demonstrated between survivors and nonsurvivors at Day 28, but patients who do not respond to therapeutics at 6 h seem to be more hypercoagulable. More importantly, if our results evidence heterogeneity between patients, we show that alterations of coagulation result in an equilibrium in the majority of patients, thus suggesting "normocoagulability"; but, in the presence of a biological imbalance between baseline thrombin generation and sensitivity to TM, the global effect mostly tends toward hypercoagulability. Thus, TGT may help identify distinct biological coagulation phenotypes in the complex alterations induced by sepsis.

  15. Biomaterials trigger endothelial cell activation when co-incubated with human whole blood.

    PubMed

    Herklotz, Manuela; Hanke, Jasmin; Hänsel, Stefanie; Drichel, Juliane; Marx, Monique; Maitz, Manfred F; Werner, Carsten

    2016-10-01

    Endothelial cell activation resulting from biomaterial contact or biomaterial-induced blood activation may in turn also affect hemostasis and inflammatory processes in the blood. Current in vitro hemocompatibility assays typically ignore these modulating effects of the endothelium. This study describes a co-incubation system of human whole blood, biomaterial and endothelial cells (ECs) that was developed to overcome this limitation. First, human endothelial cells were characterized in terms of their expression of coagulation- and inflammation-relevant markers in response to various activators. Subsequently, their capacity to regulate hemostasis as well as complement and granulocyte activation was monitored in a hemocompatibility assay. After blood contact, quiescent ECs exhibited anticoagulant and anti-inflammatory properties. When they were co-incubated with surfaces exhibiting pro-coagulant or pro-inflammatory characteristics, the ECs down-regulated coagulation but not complement or leukocyte activation. Analysis of intracellular levels of the endothelial activation markers E-selectin and tissue factor showed that co-incubation with model surfaces and blood significantly increased the activation state of ECs. Finally, the coagulation- and inflammation-modulating properties of the ECs were tested after blood/biomaterial exposure. Pre-activation of ECs by biomaterials in the blood induced a pro-coagulant and pro-inflammatory state of the ECs, wherein the pro-coagulant response was higher for biomaterial/blood pre-activated ECs than for TNF-α-pre-activated cells. This work provides evidence that biomaterials, even without directly contacting the endothelium, affect the endothelial activation state with and have consequences for plasmatic and cellular reactions in the blood. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mantero, Sara; Longo, Iginio; Fiore, Gianfranco Beniamino

    Purpose: The aim of this study was to create, perfect and test a hyperthermia balloon catheter for local treatment of cholangiocarcinoma. The device should induce hyperthermia in tumor tissue by acting locally in the bile duct lumen in contact with the tumor-infiltrated duct wall. In addition, it should exert tissue compression to cause an appreciable reduction in tumor microvasculature flow, thus improving thermal performance. Methods: According to the design specifications, the working temperature range should allow the device to be used for hyperthermia therapy either in combination with radiation and/or chemotherapy(radio/chemo-sensitizing effect at 42-45 deg. C) or alone (induction ofmore » coagulation necrosis above 65 deg. C). The balloon serves as an anchoring system during treatment and as a functional element to induce tissue compression. In vitro mechanical evaluation of the pressure/volume relationship, with the balloon inside rigid walled conduits, was performed. The heating shape around the catheter tip was determined by egg-white heating tests (coagulation at about 65 deg. C). Moreover,heating tests were carried out with explanted pig liver parenchyma. The temperature profile over time at different depths from the catheter axis was traced. Results: Three prototypes were manufactured. Mechanical functional tests showed that a 14 Fr deflated diameter balloon was suitable for bile duct diameters up to 11 mm.Thermal egg-white tests produced 4 cm long, 3 cm in diameter ellipsoidal heating figures in 30 min. In the biological tissue tests a coagulated area of similar geometry and comparable volume was produced. Conclusion: The results of tests confirm the device's usefulness and versatility.« less

  17. Stray electrical currents in laparoscopic instruments used in da Vinci® robot-assisted surgery: an in vitro study.

    PubMed

    Mendez-Probst, Carlos E; Vilos, George; Fuller, Andrew; Fernandez, Alfonso; Borg, Paul; Galloway, David; Pautler, Stephen E

    2011-09-01

    The da Vinci(®) surgical system requires the use of electrosurgical instruments. The re-use of such instruments creates the potential for stray electrical currents from capacitive coupling and/or insulation failure. We used objective measures to report the prevalence and magnitude of such stray currents. Thirty-seven robotic instruments were tested using an electrosurgical unit (ESU) at pure coagulation and cut waveforms at four different settings. Conductive gel-coated instruments were tested at 40W, 80W, and maximum ESU output (coagulation 120W, cut 300W). The magnitude of stray currents was measured by an electrosurgical analyzer. At coagulation waveform in open air, 86% of instruments leaked a mean of 0.4W. In the presence of gel-coated instruments, stray currents were detected in all instruments with means (and standard deviation) of 3.4W (± 2), 4.1W (± 2.3), and 4.1W (± 2.3) at 40W, 80W, and 120W, respectively. At cut waveform in open air, none of the instruments leaked current, while gel-coated instruments leaked a mean of 2.2W (± 1.3), 2.2W (± 1.9) and 3.2W (± 1.9) at 40W, 80W, and 300W, respectively. All tested instruments in our study demonstrated energy leakage. Stray currents were higher during coagulation (high voltage) waveforms, and the magnitude was not always proportionate to the ESU settings. Stray currents have the potential to cause electrical burns. We support the programmed end of life of da Vinci instruments on the basis of safety. Consideration should be given to alternate energy sources or the adoption of active electrode monitoring technology to all monopolar instruments.

  18. Prevalence of nucleic acid sequences specific for human parvoviruses, hepatitis A and hepatitis E viruses in coagulation factor concentrates.

    PubMed

    Modrow, S; Wenzel, J J; Schimanski, S; Schwarzbeck, J; Rothe, U; Oldenburg, J; Jilg, W; Eis-Hübinger, A M

    2011-05-01

    Due to their high resistance to inactivation procedures, nonenveloped viruses such as parvovirus B19, human bocavirus (HBoV), human parvovirus 4 (PARV4), hepatitis A (HAV) and hepatitis E virus (HEV) pose a particular threat to blood products. Virus transmission to patients treated with blood products presents an additional burden to disease. We determined the frequency and the amount of nucleic acid specific for nonenveloped viruses in recently manufactured preparations of commercial coagulation factor concentrates. At least three different batches of each of 13 different plasma-derived and recombinant coagulation factor products were tested for the presence and the amount of nucleic acid for parvovirus B19, HBoV, human parvovirus 4, hepatitis A virus and HEV by using quantitative polymerase chain reaction. Whereas none of the recombinant products tested positive for any of these viruses, parvovirus B19 DNA with amounts ranging between 2×10(1) and 1.3×10(3) genome equivalents/ml was detected in five plasma-derived products. In addition to parvovirus B19 genotype 1, genotypes 2 and 3 were observed in two batches of a factor VIII/von-Willebrand factor product. In two products (one factor VIII concentrate and one activated prothrombin complex concentrate), a combination of both genotypes 1 and 2 of parvovirus B19 was detected. The data show that nucleic acids from several relevant nonenveloped viruses are not found at detectable levels in coagulation factor concentrates. In some cases, parvovirus B19 DNA was detectable at low levels. Testing of the plasma pools for the full range of parvovirus genotypes is advocated for ensuring product safety. © 2010 The Author(s). Vox Sanguinis © 2010 International Society of Blood Transfusion.

  19. Laboratory assessment of warfarin reversal with global coagulation tests versus international normalized ratio in patients with intracranial bleeding.

    PubMed

    Voils, Stacy A; Martin, Erika J; Mohammed, Bassem M; Bayrlee, Ahmad; Brophy, Donald F

    2015-06-01

    We assess the in-vivo relationship between international normalized ratio (INR) and global coagulation tests in patients with life-threatening bleeding who received prothrombin complex concentrate (PCC) for warfarin reversal. This was a prospective pilot study in adult patients with intracranial bleeding related to anticoagulation with warfarin. Thromboelastography (TEG), thrombin generation parameters and INR were assessed at baseline, 30  min, 2 and 24  h after PCC. Changes in laboratory parameters and relationship between INR and global coagulation tests were assessed over time. Eight patients mean [standard deviation (SD)] age 72 (16) were included and received mean (SD) dose of PCC 24 (5) units/kg. Four patients died during the study, all with INR values more than 1.5 thirty minutes after PCC. Mean (SD) INR was 3.0 (1.3) and decreased significantly to 1.8 (0.48) thirty minutes after PCC (P < 0.01). Baseline endogenous thrombin potential and thrombin peak were 890  nmol/min and 123  nmol and increased significantly to 1943  nmol/min (P < 0.01) and 301  nmol (P < 0.01) 30  min after PCC administration. Reaction (R)-time decreased significantly (P = 0.02), and maximum amplitude and overall coagulation index (CI) significantly increased during treatment (P < 0.01, respectively). Thrombin generation and TEG values corrected after PCC administration; however, INR did not fully correct. Patients that died tended to be older with prolonged INR values across the study period. INR and TEG values correlated well with thrombin generation before administration of PCC, but this relationship was lost afterward.

  20. In vitro impairment of whole blood coagulation and platelet function by hypertonic saline hydroxyethyl starch.

    PubMed

    Hanke, Alexander A; Maschler, Stephanie; Schöchl, Herbert; Flöricke, Felix; Görlinger, Klaus; Zanger, Klaus; Kienbaum, Peter

    2011-02-10

    Hypertonic saline hydroxyethyl starch (HH) has been recommended for first line treatment of hemorrhagic shock. Its effects on coagulation are unclear. We studied in vitro effects of HH dilution on whole blood coagulation and platelet function. Furthermore 7.2% hypertonic saline, 6% hydroxyethylstarch (as ingredients of HH), and 0.9% saline solution (as control) were tested in comparable dilutions to estimate specific component effects of HH on coagulation. The study was designed as experimental non-randomized comparative in vitro study. Following institutional review board approval and informed consent blood samples were taken from 10 healthy volunteers and diluted in vitro with either HH (HyperHaes, Fresenius Kabi, Germany), hypertonic saline (HT, 7.2% NaCl), hydroxyethylstarch (HS, HAES6%, Fresenius Kabi, Germany) or NaCl 0.9% (ISO) in a proportion of 5%, 10%, 20% and 40%. Coagulation was studied in whole blood by rotation thrombelastometry (ROTEM) after thromboplastin activation without (ExTEM) and with inhibition of thrombocyte function by cytochalasin D (FibTEM), the latter was performed to determine fibrin polymerisation alone. Values are expressed as maximal clot firmness (MCF, [mm]) and clotting time (CT, [s]). Platelet aggregation was determined by impedance aggregrometry (Multiplate) after activation with thrombin receptor-activating peptide 6 (TRAP) and quantified by the area under the aggregation curve (AUC [aggregation units (AU)/min]). Scanning electron microscopy was performed to evaluate HyperHaes induced cell shape changes of thrombocytes. 2-way ANOVA for repeated measurements, Bonferroni post hoc test, p < 0.01. Dilution impaired whole blood coagulation and thrombocyte aggregation in all dilutions in a dose dependent fashion. In contrast to dilution with ISO and HS, respectively, dilution with HH as well as HT almost abolished coagulation (MCFExTEM from 57.3 ± 4.9 mm (native) to 1.7 ± 2.2 mm (HH 40% dilution; p < 0.0001) and to 6.6 ± 3.4 mm (HT 40% dilution; p < 0.0001) and thrombocyte aggregation (AUC from 1067 ± 234 AU/mm (native) to 14.5 ± 12.5 AU/mm (HH 40% dilution; p < 0.0001) and to 20.4 ± 10.4 AU/min (HT 40% dilution; p < 0.0001) without differences between HH and HT (MCF: p = 0.452; AUC: p = 0.449). HH impairs platelet function during in vitro dilution already at 5% dilution. Impairment of whole blood coagulation is significant after 10% dilution or more. This effect can be pinpointed to the platelet function impairing hypertonic saline component and to a lesser extend to fibrin polymerization inhibition by the colloid component or dilution effects.Accordingly, repeated administration and overdosage should be avoided.

  1. In Vitro impairment of whole blood coagulation and platelet function by hypertonic saline hydroxyethyl starch

    PubMed Central

    2011-01-01

    Background Hypertonic saline hydroxyethyl starch (HH) has been recommended for first line treatment of hemorrhagic shock. Its effects on coagulation are unclear. We studied in vitro effects of HH dilution on whole blood coagulation and platelet function. Furthermore 7.2% hypertonic saline, 6% hydroxyethylstarch (as ingredients of HH), and 0.9% saline solution (as control) were tested in comparable dilutions to estimate specific component effects of HH on coagulation. Methods The study was designed as experimental non-randomized comparative in vitro study. Following institutional review board approval and informed consent blood samples were taken from 10 healthy volunteers and diluted in vitro with either HH (HyperHaes®, Fresenius Kabi, Germany), hypertonic saline (HT, 7.2% NaCl), hydroxyethylstarch (HS, HAES6%, Fresenius Kabi, Germany) or NaCl 0.9% (ISO) in a proportion of 5%, 10%, 20% and 40%. Coagulation was studied in whole blood by rotation thrombelastometry (ROTEM) after thromboplastin activation without (ExTEM) and with inhibition of thrombocyte function by cytochalasin D (FibTEM), the latter was performed to determine fibrin polymerisation alone. Values are expressed as maximal clot firmness (MCF, [mm]) and clotting time (CT, [s]). Platelet aggregation was determined by impedance aggregrometry (Multiplate) after activation with thrombin receptor-activating peptide 6 (TRAP) and quantified by the area under the aggregation curve (AUC [aggregation units (AU)/min]). Scanning electron microscopy was performed to evaluate HyperHaes induced cell shape changes of thrombocytes. Statistics: 2-way ANOVA for repeated measurements, Bonferroni post hoc test, p < 0.01. Results Dilution impaired whole blood coagulation and thrombocyte aggregation in all dilutions in a dose dependent fashion. In contrast to dilution with ISO and HS, respectively, dilution with HH as well as HT almost abolished coagulation (MCFExTEM from 57.3 ± 4.9 mm (native) to 1.7 ± 2.2 mm (HH 40% dilution; p < 0.0001) and to 6.6 ± 3.4 mm (HT 40% dilution; p < 0.0001) and thrombocyte aggregation (AUC from 1067 ± 234 AU/mm (native) to 14.5 ± 12.5 AU/mm (HH 40% dilution; p < 0.0001) and to 20.4 ± 10.4 AU/min (HT 40% dilution; p < 0.0001) without differences between HH and HT (MCF: p = 0.452; AUC: p = 0.449). Conclusions HH impairs platelet function during in vitro dilution already at 5% dilution. Impairment of whole blood coagulation is significant after 10% dilution or more. This effect can be pinpointed to the platelet function impairing hypertonic saline component and to a lesser extend to fibrin polymerization inhibition by the colloid component or dilution effects. Accordingly, repeated administration and overdosage should be avoided. PMID:21310047

  2. Genetic parameters of coagulation properties, milk yield, quality, and acidity estimated using coagulating and noncoagulating milk information in Brown Swiss and Holstein-Friesian cows.

    PubMed

    Cecchinato, A; Penasa, M; De Marchi, M; Gallo, L; Bittante, G; Carnier, P

    2011-08-01

    The aim of this study was to estimate heritabilities of rennet coagulation time (RCT) and curd firmness (a(30)) and their genetic correlations with test-day milk yield, composition (fat, protein, and casein content), somatic cell score, and acidity (pH and titratable acidity) using coagulating and noncoagulating (NC) milk information. Data were from 1,025 Holstein-Friesian (HF) and 1,234 Brown Swiss (BS) cows, which were progeny of 54 HF and 58 BS artificial insemination sires, respectively. Milk coagulation properties (MCP) of each cow were measured once using a computerized renneting meter and samples not exhibiting coagulation within 31 min after rennet addition were classified as NC milk. For NC samples, RCT was unobserved. Multivariate analyses, using Bayesian methodology, were performed to estimate the genetic relationships of RCT or a(30) with the other traits and statistical inference was based on the marginal posterior distributions of parameters of concern. For analyses involving RCT, a right-censored Gaussian linear model was used and records of NC milk samples, being censored records, were included as unknown parameters in the model implementing a data augmentation procedure. Rennet coagulation time was more heritable [heritability (h(2))=0.240 and h(2)=0.210 for HF and BS, respectively] than a(30) (h(2)=0.148 and h(2)=0.168 for HF and BS, respectively). Milk coagulation properties were more heritable than a single test-day milk yield (h(2)=0.103 and h(2)=0.097 for HF and BS, respectively) and less heritable than milk composition traits whose heritability ranged from 0.275 to 0.275, with the only exception of fat content of BS milk (h(2)=0.108). A negative genetic correlation, lower than -0.85, was estimated between RCT and a(30) for both breeds. Genetic relationships of MCP with yield and composition were low or moderate and favorable. The genetic correlation of somatic cell score with RCT in BS cows was large and positive and even more positive were those of RCT with pH and titratable acidity in both breeds, ranging from 0.80 to 0.94. Including NC milk information in the data affected the estimated correlations and decreased the uncertainty associated with the estimation process. On the basis of the estimated heritabilities and genetic correlations, enhancement of MCP through selective breeding with no detrimental effects on yield and composition seems feasible in both breeds. Milk acidity may play a role as an indicator trait for indirect enhancement of MCP. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Laboratory hemostasis: from biology to the bench.

    PubMed

    Lippi, Giuseppe; Favaloro, Emmanuel J

    2018-06-27

    Physiological hemostasis is an intricate biological system, where procoagulant and anticoagulant forces interplay and preserves blood fluidity when blood vessels are intact, or trigger clot formation to prevent excessive bleeding when blood vessels are injured. The modern model of hemostasis is divided into two principal phases. The first, defined as primary hemostasis, involves the platelet-vessel interplay, whilst the second, defined as secondary hemostasis, mainly involves coagulation factors, damaged cells and platelet surfaces, where the so-called coagulation cascade rapidly develops. The activation and amplification of the coagulation cascade is finely modulated by the activity of several physiological inhibitors. Once bleeding has been efficiently stopped by blood clot formation, dissolution of the thrombus is essential to restore vessel permeability. This process, known as fibrinolysis, also develops through coordinate action of a vast array of proteins and enzymes. An accurate diagnosis of hemostasis disturbance entails a multifaceted approach, encompassing family and personal history of hemostatic disorders, accurate collection of clinical signs and symptoms, integrated with laboratory hemostasis testing. Regarding laboratory testing, a reasonable approach entails classifying hemostasis testing according to cost, complexity and available clinical information. Laboratory workout may hence initiate with some rapid and inexpensive "screening" tests, characterized by high negative predictive value, then followed by second- or third-line analyses, specifically aimed to clarify the nature and severity of bleeding or thrombotic phenotype. This article aims to provide a general overview of the hemostatic process, and to provide some general suggestions to optimally facilitate laboratory hemostasis testing.

  4. Comprehensive reuse of drinking water treatment residuals in coagulation and adsorption processes.

    PubMed

    Jung, Kyung-Won; Hwang, Min-Jin; Park, Dae-Seon; Ahn, Kyu-Hong

    2016-10-01

    While drinking water treatment residuals (DWTRs) inevitably lead to serious problems due to their huge amount of generation and limitation of landfill sites, their unique properties of containing Al or Fe contents make it possible to reuse them as a beneficial material for coagulant recovery and adsorbent. Hence, in the present study, to comprehensively handle and recycle DWTRs, coagulant recovery from DWTRs and reuse of coagulant recovered residuals (CRs) were investigated. In the first step, coagulant recovery from DWTRs was conducted using response surface methodology (RSM) for statistical optimization of independent variables (pH, solid content, and reaction time) on response variable (Al recovery). As a result, a highly acceptable Al recovery of 97.5 ± 0.4% was recorded, which corresponds to 99.5% of the predicted Al recovery. Comparison study of recovered and commercial coagulant from textile wastewater treatment indicated that recovered coagulant has reasonable potential for use in wastewater treatment, in which the performance efficiencies were 68.5 ± 2.1% COD, 97.2 ± 1.9% turbidity, and 64.3 ± 1.0% color removals at 50 mg Al/L. Subsequently, in a similar manner, RSM was also applied to optimize coagulation conditions (Al dosage, initial pH, and reaction time) for the maximization of real cotton textile wastewater treatment in terms of COD, turbidity, and color removal. Overall performance revealed that the initial pH had a remarkable effect on the removal performance compared to the effects of other independent variables. This is mainly due to the transformation of metal species form with increasing or decreasing pH conditions. Finally, a feasibility test of CRs as adsorbent for phosphate adsorption from aqueous solution was conducted. Adsorption equilibrium of phosphate at different temperatures (10-30 °C) and initial levels of pH (3-11) indicated that the main mechanisms of phosphate adsorption onto CRs are endothermic and chemical precipitation; the surfaces are energetically heterogeneous for adsorbing phosphate. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Reference intervals of citrated-native whole blood thromboelastography in premature neonates.

    PubMed

    Motta, Mario; Guaragni, Brunetta; Pezzotti, Elena; Rodriguez-Perez, Carmen; Chirico, Gaetano

    2017-12-01

    Bleeding due to acquired coagulation disorders is a common complication in premature neonates. In this clinical setting, standard coagulation laboratory tests might be unsuitable to investigate the hemostatic function as they reflect the concentration of pro-coagulant proteins but not of anti-coagulant proteins. Thromboelastography (TEG), providing a more complete assessment of hemostasis, may be able to overcome some of these limitations. Unfortunately, experience on the use of TEG in premature neonates is very limited and, in particular in this population, reference ranges of TEG parameters have not been yet evaluated. To evaluate TEG in preterm neonates, and to assess their reference ranges. One hundred and eighteen preterm neonates were analyzed for TEG in a retrospective cohort study. Double-sided 95% reference intervals were calculated using a bootstrap method after Box-Cox transformation. TEG parameters were compared between early-preterm and moderate-/late-preterm neonates and between bleeding and non-bleeding preterm neonates. Comparing early-preterm with moderate-/late-preterm neonates, TEG parameters were not statistically different, except for fibrinolysis which was significantly higher in early preterm neonates. Platelet count significantly correlated with α angle and MA parameters. Bleeding and non-bleeding neonates had similar TEG values. These results reinforce the concept that in stable preterm neonates, in spite of lower concentration of pro- and anti-coagulants proteins, the hemostasis is normally balanced and well functioning. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Partial Thromboplastin Time (PTT, aPTT)

    MedlinePlus

    ... through http://www.cap.org . Activated Partial Thromboplastin Time. Florida Hospital Cancer Institute, Clinical and Research Laboratories Coagulation Test Panels [On-line information]. Available ...

  7. Using Chitosan/CHPATC as coagulant to remove color and turbidity of industrial wastewater: Optimization through RSM design.

    PubMed

    Momeni, Meysam Mohammad; Kahforoushan, Davood; Abbasi, Farhang; Ghanbarian, Saeid

    2018-04-01

    One of the most important solid-liquid separation processes is coagulation and flocculation that is extensively used in the primary treatment of industrial wastewater. The biopolymers, because of biodegradable properties and low cost have been used as coagulants. In this study, chitosan as a natural coagulant of choice, was modified by (3-chloro 2-hydroxypropyl)trimethylammonium chloride and was used to remove the color and turbidity of industrial wastewater. To evaluate the effect of pH, settling time, the initial turbidity of wastewater, the amount of coagulant, and the concentration of dye (Melanoidin) were chosen to study their effects on removal of wastewater color and turbidity. The experiments were done in a batch system by using a jar test. To achieve the optimum conditions for the removal of color and turbidity, the response surface methodology (RSM) experimental design method was used. The results obtained from experiments showed that the optimum conditions for the removal of color were as: pH = 3, concentration of dye = 1000 mg/L, settling time = 78.93 min, and dose of coagulant = 3 g/L. The maximum color removal in these conditions was predicted 82.78% by the RSM model. The optimal conditions for the removal of turbidity of the waste water were as: pH = 5.66, initial turbidity = 60 NTU, settling time = 105 min, and amount of coagulant = 3 g/L. The maximum turbidity removal in these circumstances was predicted 94.19% by the model. The experimental results obtained in optimum conditions for removal of color and turbidity were 76.20% and 90.14%, respectively, indicating the high accuracy of the prediction model. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Epsilon-aminocaproic Acid for Treatment of Fibrinolysis during Liver Transplantation

    PubMed Central

    Kang, Yoogoo; Lewis, Jessica H.; Navalgund, Ashok; Russell, Michael W.; Bontempo, Franklin A.; Niren, Lawrence S.; Starzl, Thomas E.

    2010-01-01

    In 97 adult patients receiving liver transplants, the coagulation system was monitored by thrombelastography and by coagulation profile including PT; aPTT; platelet count; level of factors I, II, V, VII, VIII, IX, X, XI, and XII; fibrin degradation products; ethanol gel test; protamine gel test; and euglobulin lysis time. Preoperatively, fibrinolysis defined as a whole blood clot lysis index of less than 80% was present in 29 patients (29.9%), and a euglobulin lysis time of less than 1 h was present in 13 patients. Fibrinolysis increased progressively during surgery in 80 patients (82.5%) and was most severe on reperfusion of the graft liver in 33 patients (34%). When whole blood clot lysis (F < 180 min) was observed during reperfusion of the graft liver, blood coagulability was tested by thrombelastography using both a blood sample treated in vitro with ε-aminocaproic acid (0.09%) and an untreated sample. Blood treated with ε-aminocaproic acid showed improved coagulation without fibrinolytic activity in all 74 tests. When whole blood clot lysis time was less than 120 min, generalized oozing occurred, and the effectiveness of ε-aminocaproic acid was demonstrated in vitro during the pre-anhepatic and post-anhepatic stages, ε-aminocaproic acid (1 g, single intravenous dose) was administered. In all 20 patients treated with ε-aminocaproic acid, fibrinolytic activity disappeared; whole blood clot lysis was not seen on thrombelastography during a 5-h observation period, and whole blood clot lysis index improved from 28.5 ± 29.5% to 94.8 ± 7.4% (mean ± SD, P < 0.001). None of the treated patients had hemorrhagic or thrombotic complications. In patients undergoing liver transplantation, the judicious use of a small dose of ε-aminocaproic acid, when its efficacy was confirmed in vitro, effectively treated the severe fibrinolysis without clinical thrombotic complications. PMID:3296855

  9. Moringa oleifera-mediated coagulation of textile wastewater and its biodegradation using novel consortium-BBA grown on agricultural waste substratum.

    PubMed

    Bedekar, Priyanka A; Bhalkar, Bhumika N; Patil, Swapnil M; Govindwar, Sanjay P

    2016-10-01

    Generation of secondary sludge is a major concern of textile dye removal by coagulation process. Combinatorial coagulation-biodegradation treatment system has been found efficient in degradation of coagulated textile dye sludge. Moringa oleifera seed powder (700 mg L -1 ) was able to coagulate textile dyestuff from real textile wastewater with 98 % color removal. Novel consortium-BBA was found to decolorize coagulated dye sludge. Parameters that significantly affect coagulation process were optimized using response surface methodology. The bench-scale stirred tank reactor (50-L capacity) designed with optimized parameters for coagulation process could efficiently remove 98, 89, 78, and 67 % of American Dye Manufacturer's Institute (ADMI) in four repetitive cycles, respectively. Solid-state fermentation composting reactor designed to treat coagulated dye sludge showed 96 % removal of dye within 10 days. Coagulation of dyes from textile wastewater and degradation of coagulated dye sludge were confirmed by Fourier transform infrared spectroscopy (FTIR) analysis. Cell morphology assay, comet assay, and phytotoxicity confirmed the formation of less toxic products after coagulation and degradation mechanism.

  10. Clinical presentation and blood gas analysis of multiple trauma patients for prediction of standard coagulation parameters at emergency department arrival.

    PubMed

    Hilbert-Carius, P; Hofmann, G O; Lefering, R; Stuttmann, R; Struck, M F

    2016-04-01

    Trauma-induced coagulopathy (TIC) in multiple trauma patients is a potentially lethal complication. Whether quickly available laboratory parameters using point-of-care (POC) blood gas analysis (BGA) may serve as surrogate parameters for standard coagulation parameters is unknown. The present study evaluated TraumaRegister DGU® of the German Trauma Society for correlations between POC BGA parameters and standard coagulation parameters. In the setting of 197 trauma centres (172 in Germany), 86,442 patients were analysed between 2005 and 2012. Of these, 40,129 (72% men) with a mean age 46 ± 21 years underwent further analysis presenting with direct admission from the scene of the accident to a trauma centre, injury severity score (ISS) ≥ 9, complete data available for the calculation of revised injury severity classification prognosis, and blood samples with valid haemoglobin (Hb) measurements taken immediately after emergency department (ED) admission. Correlations between standard coagulation parameters and POC BGA parameters (Hb, base excess [BE], lactate) were tested using Pearson's test with a two-tailed significance level of p < 0.05. A subgroup analysis including patients with ISS > 16, ISS > 25, ISS > 16 and shock at ED admission, and patients with massive transfusion was likewise carried out. Correlations were found between Hb and prothrombin time (r = 0.497; p < 0.01), Hb and activated partial thromboplastin time (aPTT; r = -0.414; p < 0.01), and Hb and platelet count (PLT; r = 0.301; p < 0.01). Patients presenting with ISS ≥ 16 and shock (systolic blood pressure < 90 mmHg) at ED admission (n = 4,329) revealed the strongest correlations between Hb and prothrombin time (r = 0.570; p < 0.01), Hb and aPTT (r = -0.457; p < 0.01), and Hb and PLT (r = 0.412; p < 0.01). Significant correlations were also found between BE and prothrombin time (r = -0.365; p < 0.01), and BE and aPTT (r = 0.327, p < 0.01). No correlations were found between Hb, BE and lactate lactate. POC BGA parameters Hb and BE of multiple trauma patients correlated with standard coagulation parameters in a large database analysis. These correlations were particularly strong in multiple trauma patients presenting with ISS > 16 and shock at ED admission. This may be relevant for hospitals with delayed availability of coagulation studies and those without viscoelastic POC devices. Future studies may determine whether clinical presentation/BGA-oriented coagulation therapy is an appropriate tool for improving outcomes after major trauma.

  11. Asphyxia by Drowning Induces Massive Bleeding Due To Hyperfibrinolytic Disseminated Intravascular Coagulation.

    PubMed

    Schwameis, Michael; Schober, Andreas; Schörgenhofer, Christian; Sperr, Wolfgang Reinhard; Schöchl, Herbert; Janata-Schwatczek, Karin; Kürkciyan, Erol Istepan; Sterz, Fritz; Jilma, Bernd

    2015-11-01

    To date, no study has systematically investigated the impact of drowning-induced asphyxia on hemostasis. Our objective was to test the hypothesis that asphyxia induces bleeding by hyperfibrinolytic disseminated intravascular coagulation. Observational study. A 2,100-bed tertiary care facility in Vienna, Austria, Europe. All cases of drowning-induced asphyxia (n=49) were compared with other patients with cardiopulmonary resuscitation (n=116) and to patients with acute promyelocytic leukemia (n=83). Six drowning victims were investigated prospectively. To study the mechanism, a forearm-ischemia model was used in 20 volunteers to investigate whether hypoxia releases tissue plasminogen activator. None. Eighty percent of patients with drowning-induced asphyxia developed overt disseminated intravascular coagulation within 24 hours. When compared with nondrowning cardiac arrest patients, drowning patients had a 13 times higher prevalence of overt disseminated intravascular coagulation at admission (55% vs 4%; p<0.001). Despite comparable disseminated intravascular coagulation scores, acute promyelocytic leukemia patients had higher fibrinogen but lower d-dimer levels and platelet counts than drowning patients (p<0.001). Drowning victims had a three-fold longer activated partial thromboplastin time (124 s; p<0.001) than both nondrowning cardiac arrest and acute promyelocytic leukemia patients. Hyperfibrinolysis was reflected by up to 1,000-fold increased d-dimer levels, greater than 5-fold elevated plasmin antiplasmin levels, and a complete absence of thrombelastometric clotting patterns, which was reversed by antifibrinolytics and heparinase. Thirty minutes of forearm-ischemia increased tissue plasminogen activator 31-fold (p<0.001). The vast majority of drowning patients develops overt hyperfibrinolytic disseminated intravascular coagulation, partly caused by hypoxia induced tissue plasminogen activator release. Antifibrinolytics and heparinase partially reverse the abnormal clotting patterns. Severe activated partial thromboplastin time prolongation may be a marker of combined hyperfibrinolytic afibrinogenemia and autoheparinization in drowning-related asphyxia.

  12. Simple and rapid methods for purification and characterization of active coagulants from the seeds of Vigna unguiculata and Parkinsonia aculeata.

    PubMed

    Marobhe, N J; Dalhammar, G; Gunaratna, K R

    2007-06-01

    The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.

  13. Jar Test. Operational Control Tests for Wastewater Treatment Facilities. Instructor's Manual [and] Student Workbook.

    ERIC Educational Resources Information Center

    Arasmith, E. E.

    The jar test is used to determine the proper chemical dosage required for good coagulation and flocculation of water. The test is commonly used in potable water, secondary effluent prior to advanced wastewater treatment, secondary clarifier influent, and sludge conditioning practice. Designed for individuals who have completed National Pollutant…

  14. Blood Hypomethylation of Inflammatory Genes Mediates the Effects of Metal-rich Airborne Pollutants on Blood Coagulation

    PubMed Central

    Tarantini, Letizia; Bonzini, Matteo; Tripodi, Armando; Angelici, Laura; Nordio, Francesco; Cantone, Laura; Apostoli, Pietro; Bertazzi, Pier Alberto; Baccarelli, Andrea A.

    2014-01-01

    Objectives Recent investigations have associated airborne Particulate Matter (PM) with increased coagulation and thrombosis, but underlying biological mechanisms are still incompletely characterized. DNA methylation is an environmentally-sensitive mechanism of gene regulation that could potentially contribute to PM-induced hypercoagulability. We aimed to test whether altered methylation mediates environmental effects on coagulation. Methods We investigated 63 steel workers exposed to a wide range of PM levels, as a work-related condition with well-characterized prothrombotic exposure. We measured personal PM10 (PM≤10 μm in aerodynamic diameter), PM1 (≤1 μm), and air metal components. We determined leukocyte DNA methylation of NOS3 (nitric-oxide-synthase-3) and EDN1 (endothelin-1) through bisulfite-pyrosequencing and we measured Endogenous Thrombin Potential (ETP), as a global coagulation-activation test after standardized triggers. Results ETP increased in association with PM10 (β=20.0, 95%CI: 3.0, 37.0), PM1 (β=80.8 95%CI: 14.9, 146.7), and zinc (β=51.3, 95%CI: 0.01, 111.1) exposures. NOS3 methylation was negatively associated with PM10 (β=−0.2, 95%CI: −0.4, −0.03), PM1 (β=−0.8, 95%CI: −1.4, −0.1), zinc (β=−0.9, 95%CI: −1.4, −0.3) and iron (β=−0.7, 95%CI: −1.4, −0.01) exposures. Zinc exposure was negatively associated with EDN1 (β=−0.3, 95%CI: −0.8, −0.1) methylation. Lower NOS3 (β=−42.3; p<0.001) and EDN1 (β=−14.5; p=0.05) were associated with higher ETP. Statistical mediation analysis formally confirmed NOS3 and EDN1 hypomethylation as intermediate mechanisms for PM-related coagulation effects. Conclusions Our study showed for the first time, that gene hypomethylation contributes to environmentally-induced hypercoagulability. PMID:23476046

  15. [Coagulation and adsorption on treating the Yellow River and the impact on chlorine decay during chlorination process].

    PubMed

    Zhan, Xiao; Gao, Bao-yu; Liu, Bin; Xu, Chun-hua; Yue, Qin-yan

    2010-05-01

    Two types of inorganic polymer coagulants, polyferric chloride (PFC) and polyaluminum chloride (PAC), were chosen to treat the Yellow River water. Different dosages were investigated in order to investigate the turbidity, UV24, DOC and permanganate index removal efficiency and their coagulation mechanisms based on the Zeta potentials. The natural organic matter removal by the combination of coagulation and adsorption with powder activated carbon were analyzed based on different coagulant and adsorbent dosages and dosing orders. The effects of combination of coagulation and adsorption on the residual chlorine decay were analyzed. The results showed that the two coagulants had high turbidity removal efficiency ( > 90%). The UV254, DOC, permanganate index removal efficiency were 29.2%, 26.1% and 27.9% respectively for PAC coagulation and were 32.3%, 23.3% and 32.9% respectively for PFC. Electric neutralization played an important role in the PAC coagulation process while both adsorption bridging and electric neutralization performed when PFC was used. The removal percentage of organic matter increased with the increase coagulant and adsorbent. The adsorption after coagulation process gave the better UV254 and DOC removal efficiency than the coagulation after adsorption. The UV254 and DOC removal efficiency were 95.2% and 99.9% for PAC coagulation after adsorption and were 90.1% and 99.9% for PFC coagulation first. But adding powder activated carbon can improve floc settlement performance and maintained persistent disinfection effect.

  16. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...

  17. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...

  18. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...

  19. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...

  20. 21 CFR 864.7140 - Activated whole blood clotting time tests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Activated whole blood clotting time tests. 864....7140 Activated whole blood clotting time tests. (a) Identification. An activated whole blood clotting... pulmonary embolism by measuring the coagulation time of whole blood. (b) Classification. Class II...

  1. Acute management of bleeding in patients on novel oral anticoagulants.

    PubMed

    Siegal, Deborah M; Crowther, Mark A

    2013-02-01

    Novel oral anticoagulants that directly inhibit thrombin (dabigatran) or factor Xa (rivaroxaban, apixaban) are currently available for prevention of venous thromboembolism (VTE) after orthopaedic surgery, treatment of acute VTE, and prevention of arterial thromboembolism in non-valvular atrial fibrillation. These agents offer advantages over VKAs, including rapid onset, shorter half-lives, fewer drug interactions, and lack of need for routine monitoring. However, there are no established agents to reverse their anticoagulant effect. We review the risk of bleeding with the novel oral anticoagulants and the limitations of conventional coagulation assays for measuring anticoagulant effect. We provide an approach to the management of patients with bleeding complications with evidence for various interventions for reversal, where available.

  2. A Monte Carlo method for the simulation of coagulation and nucleation based on weighted particles and the concepts of stochastic resolution and merging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kotalczyk, G., E-mail: Gregor.Kotalczyk@uni-due.de; Kruis, F.E.

    Monte Carlo simulations based on weighted simulation particles can solve a variety of population balance problems and allow thus to formulate a solution-framework for many chemical engineering processes. This study presents a novel concept for the calculation of coagulation rates of weighted Monte Carlo particles by introducing a family of transformations to non-weighted Monte Carlo particles. The tuning of the accuracy (named ‘stochastic resolution’ in this paper) of those transformations allows the construction of a constant-number coagulation scheme. Furthermore, a parallel algorithm for the inclusion of newly formed Monte Carlo particles due to nucleation is presented in the scope ofmore » a constant-number scheme: the low-weight merging. This technique is found to create significantly less statistical simulation noise than the conventional technique (named ‘random removal’ in this paper). Both concepts are combined into a single GPU-based simulation method which is validated by comparison with the discrete-sectional simulation technique. Two test models describing a constant-rate nucleation coupled to a simultaneous coagulation in 1) the free-molecular regime or 2) the continuum regime are simulated for this purpose.« less

  3. Removal of natural organic matter by titanium tetrachloride: The effect of total hardness and ionic strength.

    PubMed

    Zhao, Y X; Shon, H K; Phuntsho, S; Gao, B Y

    2014-02-15

    This study is the first attempt to investigate the effect of total hardness and ionic strength on coagulation performance and the floc characteristics of titanium tetrachloride (TiCl4). Membrane fouling under different total hardness and ionic strength conditions was also evaluated during a coagulation-ultrafiltration (C-UF) hybrid process. Coagulation experiments were performed with two simulated waters, using humic acid (HA, high molecular weight) and fulvic acid (FA, relatively low molecular weight), respectively, as model natural organic matter (NOM). Results show that both particle and organic matter removal can be enhanced by increasing total hardness and ionic strength. Floc characteristics were significantly influenced by total hardness and ionic strength and were improved in terms of floc size, growth rate, strength, recoverability and compactness. The results of the UF tests show that the pre-coagulation with TiCl4 significantly improves the membrane permeate fluxes. Under different total hardness and ionic strength conditions, the membrane permeate flux varied according to both NOM and floc characteristics. The increase in total hardness and ionic strength improved the membrane permeate flux in the case of HA simulated water treatment. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. [Meta analysis of the changes of blood coagulation in patients with active ulcerative colitis].

    PubMed

    Zha, Ansheng; Wang, Yue; Zha, Ruiyao

    2015-11-01

    To evaluate the changes of blood coagulation in patients with active ulcerative colitis. We searched the PubMed, Medline, EMBASE, Web of Science, the Cochrane Library, China National Knowledge Infrastructure (CNKI), China Biology Medicine (CBM), Wanfang Database for the Chinese or English literatures published until January 2015. The data that met the inclusion criteria were screened and evaluated. After evaluation, the eligible ones were subjected to Newcastle-Ottawa Scale (NOS) and meta analysis using the Stata12.0 software. A total of 28 case-control studies were recruited for the meta analysis. The analysis results showed that the levels of platelet (PLT), fibrinogen (FIB) and D-dimer significantly increased in active ulcerative colitis group compared with normal control group. The levels of mean platelet volume (MPV) and prothrombin time (PT) significantly decreased in active ulcerative colitis group compared with normal control group. Sensitivity analysis showed that the evaluation result was stable. Egger and Begg tests suggested no evidence of substantial publication bias except for the literatures about D-dimer. Abnormal blood coagulation indexes of active ulcerative colitis patients indicate there may be high coagulation state in ulcerative colitis.

  5. The efficiency of combined coagulant and ballast to remove harmful cyanobacterial blooms in a tropical shallow system.

    PubMed

    Miranda, Marcela; Noyma, Natália; Pacheco, Felipe S; de Magalhães, Leonardo; Pinto, Ernani; Santos, Suzan; Soares, Maria Fernanda A; Huszar, Vera L; Lürling, Miquel; Marinho, Marcelo M

    2017-05-01

    We tested the hypothesis that a combination of coagulant and ballast could be efficient for removal of positively buoyant harmful cyanobacteria in shallow tropical waterbodies, and will not promote the release of cyanotoxins. This laboratory study examined the efficacy of coagulants [polyaluminium chloride (PAC) and chitosan (made of shrimp shells)] alone, and combined with ballast (lanthanum modified bentonite, red soil or gravel) to remove the natural populations of cyanobacteria collected from a shallow eutrophic urban reservoir with alternating blooms of Cylindrospermopsis and Microcystis. PAC combined with ballast was effective in settling blooms dominated by Microcystis or Cylindrospermopsis. Contrary to our expectation, chitosan combined with ballast was only effective in settling Cylindrospermopsis-dominated blooms at low pH, whereas at pH≥8 no effective flocculation and settling could be evoked. Chitosan also had a detrimental effect on Cylindrospermopsis causing the release of saxitoxins. In contrast, no detrimental effect on Microcystis was observed and all coagulant-ballast treatments were effective in not only settling the Microcystis dominated bloom, but also lowering dissolved microcystin concentrations. Our data show that the best procedure for biomass reduction also depends on the dominant species. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Effects of pentastarch and albumin infusion on cardiorespiratory function and coagulation in patients with severe sepsis and systemic hypoperfusion.

    PubMed

    Rackow, E C; Mecher, C; Astiz, M E; Griffel, M; Falk, J L; Weil, M H

    1989-05-01

    Twenty consecutive patients with severe sepsis were randomized to fluid challenge with 5% albumin or 10% low MW hydroxyethyl starch (pentastarch) solutions. Fluid challenge was administered iv as 250 ml of test colloid every 15 min until the pulmonary artery wedge pressure (WP) was greater than or equal to 15 mm Hg or a maximum dose of 2000 ml was infused. Hemodynamic, respiratory, and coagulation profiles were measured before and after fluid infusion. The amount of colloid required to achieve a WP of 15 mm Hg was comparable between groups. Both colloid infusions resulted in similar increases in cardiac output, stroke output, and stroke work. The effect of fluid infusion with pentastarch on coagulation was not significantly different from albumin, although pentastarch was associated with a 45% decrease in factor VIII:c. We conclude that pentastarch is equivalent to albumin for fluid resuscitation of patients with severe sepsis.

  7. Curcumin, hemostasis, thrombosis, and coagulation.

    PubMed

    Keihanian, Faeze; Saeidinia, Amin; Bagheri, Ramin Khameneh; Johnston, Thomas P; Sahebkar, Amirhossein

    2018-06-01

    Atherothrombotic cardiovascular disease is a major cause of mortality throughout the world. Platelet activation and aggregation play a central role in hemostasis and thrombosis. Herbal medicines have been traditionally used in the management of cardiovascular disease and can help in modifying its progression, particularly in hemostasis and the coagulation process, as well as altering platelet function tests and some coagulation parameters. Curcumin is a polyphenol derived from the Curcuma longa plant and has been used extensively in complementary and alternative medicine, as it is nontoxic and safe with various therapeutic properties. Modern scientific research has demonstrated its anti-inflammatory, antioxidant, anti-carcinogenic, antithrombotic, and cardiovascular protective effects. The present study reviewed previous studies in the literature, which support the positive activity of curcumin in hemostasis, anticoagulation, and fibrinolysis. We also presented molecular mechanisms associated with the antiplatelet and anticoagulant activities of curcumin and potential implications for the treatment of cardiovascular disease. © 2017 Wiley Periodicals, Inc.

  8. Coagulation behavior and floc characteristics of a novel composite poly-ferric aluminum chloride-polydimethyl diallylammonium chloride coagulant with different OH/(Fe3+ + Al3+) molar ratios.

    PubMed

    Sun, Cuizhen; Qiu, Jinwei; Zhang, Zhibin; Marhaba, Taha F; Zhang, Yanhao

    2016-10-01

    In this paper, flocculating performance and mechanisms of a new composite coagulant, poly-ferric aluminum chloride-polydimethyl diallylammonium chloride (PFAC-PD) with different OH - /(Fe 3+ + Al 3+ ) molar ratios, were investigated for humic acid (HA)-kaolin synthetic wastewater treatment. The impact of OH - /(Fe 3+ + Al 3+ ) molar ratios on the removal efficiencies of turbidity and dissolved organic carbon, specific UV absorbance, coagulation mechanisms and dynamics was explored during the coagulation process using composite coagulants. The coagulation experimental results revealed that the composite coagulants with lower OH - /(Fe 3+ + Al 3+ ) molar ratio exhibited better coagulation efficiency. When OH - /(Fe 3+ + Al 3+ ) molar ratio of the composite coagulant was 1.5, adsorption-bridging played a dominant role in coagulating HA-kaolin synthetic wastewater. The floc growth rate and floc size, increased with increasing OH - /(Fe 3+ + Al 3+ ) molar ratio and the highest peak height of the size distribution was obtained by PFAC-PD with OH - /(Fe 3+ + Al 3+ ) = 1.5. Also, the composite coagulants with higher OH - /(Fe 3+ + Al 3+ ) molar ratio formed more compact flocs, as reflected by the higher fractal dimension value. The flocs coagulated by PFAC-PD with basicity value of 1.0 gave strong strength and good recoverability.

  9. Comparison of single-step and two-step purified coagulants from Moringa oleifera seed for turbidity and DOC removal.

    PubMed

    Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J

    2010-08-01

    The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.

  10. Quality control in the development of coagulation factor concentrates.

    PubMed

    Snape, T J

    1987-01-01

    Limitation of process change is a major factor contributing to assurance of quality in pharmaceutical manufacturing. This is particularly true in the manufacture of coagulation factor concentrates, for which presumptive testing for poorly defined product characteristics is an integral feature of finished product quality control. The development of new or modified preparations requires that this comfortable position be abandoned, and that the effect on finished product characteristics of changes to individual process steps (and components) be assessed. The degree of confidence in the safety and efficacy of the new product will be determined by, amongst other things, the complexity of the process alteration and the extent to which the results of finished product tests can be considered predictive. The introduction of a heat-treatment step for inactivation of potential viral contaminants in coagulation factor concentrates presents a significant challenge in both respects, quite independent of any consideration of assessment of the effectiveness of the viral inactivation step. These interactions are illustrated by some of the problems encountered with terminal dry heat-treatment (72 h. at 80 degrees C) of factor VIII and prothrombin complex concentrates manufactured by the Blood Products Laboratory.

  11. Natural organic matters removal efficiency by coagulation

    NASA Astrophysics Data System (ADS)

    Sapingi, Mohd Sharizal Mohd; Pishal, Munirah; Murshed, Mohamad Fared

    2017-10-01

    The presence of Natural Organic Matter (NOM) in surface water results in unwanted characteristics in terms of color, odor, and taste. NOM content reaction with free chlorine in treated water lowers the water quality further. Chlorine is added for disinfection and produces undesirable disinfection by-products (DPBs). DBPs in drinking water are carcinogenic to consumers and may promote cancerous cell development in the human body. This study was performed to compare the coagulant efficiency of aluminum sulfate (Alum) and ferric chloride (FeCl3) on NOM removal (as in UV254 absorbance) and turbidity removal under three pH conditions (pH 6, pH 7, and sample actual pH). The three sampling points for these studies were Jalan Baru River, Kerian River, and Redac Pond. Additional sampling points, such as Lubuk Buntar and a tubewell located in the Civil Engineering School, were included to observe differences in characteristics. DOC, UV absorbance, and full wavelength were tested, after which samples treated with alum were also tested to further analyze the NOM content. Based on UV254 absorbance and DOC data, specific UV value was calculated to obtain vital synopsis of the characteristics of NOM content, as well as coagulation efficiency.

  12. Intraoperative Changes in Blood Coagulation and Thrombelastographic Monitoring in Liver Transplantation

    PubMed Central

    Kang, Yoo Goo; Martin, Douglas J.; Marquez, Jose; Lewis, Jessica H.; Bontempo, Franklin A.; Shaw, Byers W.; Starzl, Thomas E.; Winter, Peter M.

    2010-01-01

    The blood coagulation system of 66 consecutive patients undergoing consecutive liver transplantations was monitored by thrombelastograph and analytic coagulation profile. A poor preoperative coagulation state, decrease in levels of coagulation factors, progressive fibrinolysis, and whole blood clot lysis were observed during the preanhepatic and anhepatic stages of surgery. A further general decrease in coagulation factors and platelets, activation of fibrinolysis, and abrupt decrease in levels of factors V and VIII occurred before and with reperfusion of the homograft. Recovery of blood coagulability began 30–60 min after reperfusion of the graft liver, and coagulability had returned toward baseline values 2 hr after reperfusion. A positive correlation was shown between the variables of thrombelastography and those of the coagulation profile. Thrombelastography was shown to be a reliable and rapid monitoring system. Its use was associated with a 33% reduction of blood and fluid infusion volume, whereas blood coagulability was maintained without an increase in the number of blood product donors. PMID:3896028

  13. Dose Responses of Ibuprofen In Vitro on Platelet Aggregation and Coagulation in Human and Pig Blood Samples.

    PubMed

    Martini, Wenjun Z; Rodriguez, Cassandra M; Deguzman, Rodolfo; Guerra, Jessica B; Martin, Angela K; Pusateri, Anthony E; Cap, Andrew P; Dubick, Michael A

    2016-05-01

    Ibuprofen is commonly used by warfighters in the deployed environment. This study investigated its dose effects on in vitro coagulation in human and pig blood. Blood samples were collected from 6 normal volunteers and 6 healthy pigs and processed to make platelet-adjusted samples (100 × 10(3)/μL, common transfusion trigger in trauma). Ibuprofen was added to the samples at concentrations of 0 μg/mL (control), the concentration from the highest recommended oral dose (163 μg/mL, 1×), and 2×, 4×, 8×, 10×, 12×, 16×, and 20×. Platelet aggregation by Chrono-Log aggregometer and coagulation by rotational thrombelastogram (Rotem) were assessed at 15 minutes after the addition of ibuprofen. A robust inhibition of ibuprofen on arachidonic acid-induced platelet aggregation was observed at all doses tested in human or pig blood. Collagen-stimulated platelet aggregation was inhibited starting at 1× in human blood and 4× in pig blood. Rotem measurements were similarly compromised in pig and human blood starting at 16×, except clot formation time was prolonged at 1× in human blood (all p < 0.05). Ibuprofen inhibited platelet aggregation at recommended doses, and compromised coagulation at higher doses. Human blood was more sensitive to ibuprofen inhibition. Further effort is needed to investigate ibuprofen dose responses on coagulation in vivo. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  14. The influence of addition of papain enzyme and Carboxyl Methyl Cellulose on the textural properties of Tofu

    NASA Astrophysics Data System (ADS)

    Faridah; Fachraniah; Arifien; Sari, C. M.

    2018-03-01

    Papain enzyme and carboxyl methyl cellulosa was used in tofu production as coagulant and thickener. Papain enzyme is a protease enzyme that can break proteins. Papain enzymeuseful as coagulant to replace acid and base coagulant. The goal of this study is to observe papain enzyme as coagulant and carboxyl methyl cellulose as thickener to increase characteristic of tofu. Tofu is from soy milk has been pasteurized at 70 °C with the addition of papain enzyme and carboxyl methly cellulose. The concenration of papain enzyme is varied such as 200, 400, 800, and 1000 ppm. After Temperature reachs at 90 °C, carboxyl methyl cellulosa is added in soy milk to produce tofu. This study focuses on introducing papain enzyme as coagulant as well as investigating its potential in improving tofu making process productivity. Further the present work attempts to determine the synergistic effect of combining CMC/enzyme in tofu characteristic. This research was conducted with soy milk pasteurized at 70 °C with increasing papain enzyme. Protein from tofu was determined by using Spectrophotometer UV-VIS Shimadzu UV-1800 type. The highest protein concentration of the papain enzyme was found in 1000 ppm with CMC concentration of 0.6% w/v and based on organoleptic tests that the adding CMC and enzyme papain does not effect the taste, smell, texture and color of tofu. The taste of tofu produced is similar to the taste of tofu in the market.

  15. Dual purpose recovered coagulant from drinking water treatment residuals for adjustment of initial pH and coagulation aid in electrocoagulation process.

    PubMed

    Jung, Kyung-Won; Ahn, Kyu-Hong

    2016-01-01

    The present study is focused on the application of recovered coagulant (RC) by acidification from drinking water treatment residuals for both adjusting the initial pH and aiding coagulant in electrocoagulation. To do this, real cotton textile wastewater was used as a target pollutant, and decolorization and chemical oxygen demand (COD) removal efficiency were monitored. A preliminary test indicated that a stainless steel electrode combined with RC significantly accelerated decolorization and COD removal efficiencies, by about 52% and 56%, respectively, even at an operating time of 5 min. A single electrocoagulation system meanwhile requires at least 40 min to attain the similar removal performances. Subsequently, the interactive effect of three independent variables (applied voltage, initial pH, and reaction time) on the response variables (decolorization and COD removal) was evaluated, and these parameters were statistically optimized using the response surface methodology. Analysis of variance showed a high coefficient of determination values (decolorization, R(2) = 0.9925 and COD removal, R(2) = 0.9973) and satisfactory prediction second-order polynomial quadratic regression models. Average decolorization and COD removal of 89.52% and 94.14%, respectively, were achieved, corresponding to 97.8% and 98.1% of the predicted values under statistically optimized conditions. The results suggest that the RC effectively played a dual role of both adjusting the initial pH and aiding coagulant in the electrocoagulation process.

  16. Activation of Blood Coagulation in Two Prototypic Autoimmune Skin Diseases: A Possible Link with Thrombotic Risk.

    PubMed

    Cugno, Massimo; Tedeschi, Alberto; Borghi, Alessandro; Bucciarelli, Paolo; Asero, Riccardo; Venegoni, Luigia; Griffini, Samantha; Grovetti, Elena; Berti, Emilio; Marzano, Angelo Valerio

    2015-01-01

    Coagulation activation has been demonstrated in two prototypic autoimmune skin diseases, chronic autoimmune urticaria and bullous pemphigoid, but only the latter is associated with increased thrombotic risk. Two markers of coagulation activation (prothrombin fragment F1+2 and fibrin fragment D-dimer) were measured by immunoenzymatic methods in plasma samples from 30 patients with active chronic autoimmune urticaria, positive for autologous serum skin test, 30 patients with active bullous pemphigoid and 30 healthy subjects. In skin biopsies, tissue factor expression was evaluated by both immunohistochemistry and in situ hybridization. F1+2 and D-dimer levels were higher in active chronic autoimmune urticaria (276.5±89.8 pmol/L and 5.56±4.40 nmol/L, respectively) than in controls (145.2±38.0 pmol/L and 1.06±0.25 nmol/L; P=0.029 and P=0.011) and were much higher in active bullous pemphigoid (691.7±318.7 pmol/L and 15.24±9.09 nmol/L, respectively) (P<0.0001). Tissue factor positivity was evident in skin biopsies of both disorders with higher intensity in bullous pemphigoid. F1+2 and D-dimer, during remission, were markedly reduced in both disorders. These findings support the involvement of coagulation activation in the pathophysiology of both diseases. The strong systemic activation of coagulation in bullous pemphigoid may contribute to increase the thrombotic risk and provides the rationale for clinical trials on anticoagulant treatments in this disease.

  17. Toxicity of leather tanning wastewater effluents in sea urchin early development and in marine microalgae.

    PubMed

    Meriç, Süreyya; De Nicola, Elena; Iaccarino, Mario; Gallo, Marialuisa; Di Gennaro, Annamaria; Morrone, Gaetano; Warnau, Michel; Belgiorno, Vincenzo; Pagano, Giovanni

    2005-10-01

    This study was designed to investigate the composition and the toxicity of leather tanning wastewater and conditioned sludge collected at the leather tanning wastewater treatment plant (CODISO) located in Solofra, Avellino (Southern Italy). Samples were analyzed for their conventional parameters (COD, TSS, chromium and ammonia) and for metal content. Effluent samples included raw wastewater, and samples collected following coagulation/flocculation process and biological treatment. A set of toxicity endpoints were tested using sea urchin and marine microalgal bioassays by evaluating acute embryotoxicity, developmental defects, changes in sperm fertilization success and transmissible damage from sperm to the offspring, and changes in algal growth rate. Dose-related toxicity to sea urchin embryogenesis and sperm fertilization success was exerted by effluent or sludge samples according to the following rank: conditioned sludge > coagulated effluent > or = raw influent > effluent from biological treatment. Offspring quality was not affected by sperm exposure to any wastewater or to sludge samples. Algal growth was inhibited by raw or coagulated effluent to a similar extent and, again, the effluent from the biological treatment resulted in a decreased toxicity. The results suggest that coagulated effluent and conditioned sludge result in higher toxicity than raw influent in sea urchin embryos and sperm, whereas the biological wastewater treatment of coagulated effluent, in both sea urchins and algae, cause a substantial improvement of wastewater quality. Hence a final biological wastewater treatment should be operated to minimize any environmental damage from tannery wastewater.

  18. Pretreatment of bakery wastewater by coagulation-flocculation and dissolved air flotation.

    PubMed

    Liu, J C; Lien, C S

    2001-01-01

    The pretreatment of wastewater from a large-scale bakery was studied. In the coagulation-flocculation reaction, it was found that both alum and FeCl3 were effective in the jar tests. When at coagulant dosage of 90 to 100 mg/l, 55% of COD and 95 to 100% of SS could be removed. The optimum pH was at 6.0. In addition, the removal of SS was affected by pH more significantly, while the removal of COD was not affected in the pH range of 6.0 to 8.0. In the DAF experiments, 48.6% of COD and 69.8% of SS were removed in 10 min at a pressure of 4 kg/cm2, recycle ratio of 0.3 l/min, and pH of 6.0. Upon the addition of 100 mg/l of alum, the removal efficiency of COD did not increase while SS removal increased to 82.1%. It was found that 5-min flocculation time did improve the COD removal while it had little effect on SS removal. Flocculation for longer than 5 min did not enhance the flotation performance. Similar phenomena were observed when FeCl3 was used as the coagulant, except that flocculation had an insignificant effect on COD and SS removal. It was also found that FeCl3 was relatively more effective than alum. In summary, both coagulation-flocculation and DAF were efficient for the pretreatment. The advantages and disadvantages were discussed.

  19. Activation of Blood Coagulation in Two Prototypic Autoimmune Skin Diseases: A Possible Link with Thrombotic Risk

    PubMed Central

    Cugno, Massimo; Tedeschi, Alberto; Borghi, Alessandro; Bucciarelli, Paolo; Asero, Riccardo; Venegoni, Luigia; Griffini, Samantha; Grovetti, Elena; Berti, Emilio; Marzano, Angelo Valerio

    2015-01-01

    Coagulation activation has been demonstrated in two prototypic autoimmune skin diseases, chronic autoimmune urticaria and bullous pemphigoid, but only the latter is associated with increased thrombotic risk. Two markers of coagulation activation (prothrombin fragment F1+2 and fibrin fragment D-dimer) were measured by immunoenzymatic methods in plasma samples from 30 patients with active chronic autoimmune urticaria, positive for autologous serum skin test, 30 patients with active bullous pemphigoid and 30 healthy subjects. In skin biopsies, tissue factor expression was evaluated by both immunohistochemistry and in situ hybridization. F1+2 and D-dimer levels were higher in active chronic autoimmune urticaria (276.5±89.8 pmol/L and 5.56±4.40 nmol/L, respectively) than in controls (145.2±38.0 pmol/L and 1.06±0.25 nmol/L; P=0.029 and P=0.011) and were much higher in active bullous pemphigoid (691.7±318.7 pmol/L and 15.24±9.09 nmol/L, respectively) (P<0.0001). Tissue factor positivity was evident in skin biopsies of both disorders with higher intensity in bullous pemphigoid. F1+2 and D-dimer, during remission, were markedly reduced in both disorders. These findings support the involvement of coagulation activation in the pathophysiology of both diseases. The strong systemic activation of coagulation in bullous pemphigoid may contribute to increase the thrombotic risk and provides the rationale for clinical trials on anticoagulant treatments in this disease. PMID:26057532

  20. In vitro evaluation of the effect of haemodilution with dextran 40 on coagulation profile as measured by thromboelastometry and multiple electrode aggregometry.

    PubMed

    Kam, Pca; Liou, Jpc; Yang, Kxf

    2017-09-01

    We evaluated the effects of haemodilution with either dextran 40 or 0.9% normal saline on coagulation in vitro using rotational thromboelastometry (ROTEM®, Pentapharm Co., Munich, Germany) and multiple electrode aggregometry (Multiplate® Platelet Function Analyser, Dynabyte, Munich, Germany). Venous blood samples obtained from 20 healthy volunteers were diluted in vitro with dextran 40 or normal saline by 5%, 10% and 15%. Fibrinogen concentration, ROTEM-EXTEM® (screening test for the extrinsic coagulation pathway), FIBTEM® (an EXTEM-based assay of the fibrin component of clot) parameters including coagulation time, clot formation time, alpha angle, maximum clot firmness and lysis index were measured in the undiluted sample and at each level of haemodilution. Dextran 40 at 15% haemodilution significantly prolonged coagulation time, clot formation time and significantly decreased the alpha angle and maximal clot firmness (EXTEM amplitude at five minutes [A5] and ten minutes [A10]) compared with normal saline. The FIBTEM assay (maximal clot firmness and FIBTEM A5 and A10) showed a marked decrease in maximal clot firmness at all dilutions suggesting impaired fibrinogen activity and a risk of bleeding. Multiple electrode aggregometry did not demonstrate any platelet dysfunction. Haemodilution with dextran 40 causes significant impairment in clot formation and strength compared to saline haemodilution and undiluted blood. At the levels of in vitro haemodilution designed to reflect the clinical use of dextran infusions, no significant fibrinolysis or platelet inhibition was observed.

  1. Blood coagulation status of small-for-dates and postmature infants.

    PubMed Central

    Perlman, M; Dvilansky, A

    1975-01-01

    In a prospective study of blood coagulation status in small-for-dates and postmature infants there was often evidence of intravascular coagulation. Abnormal coagulation findings correlated with the degree of growth retardation and with the degree of postmaturity. Macroscopical placental infarction and neonatal polycythaemia were associated with coagulation abnormalities; asphyxia, however, was not. Intravascular coagulation may be an additional hazard to small-for-dates and postmature infants. PMID:1170815

  2. Preparation and Evaluation of Titanium-Based Xerogel as a Promising Coagulant for Water/Wastewater Treatment.

    PubMed

    Wang, Xiaomeng; Li, Minghui; Song, Xiaojie; Chen, Zhihao; Wu, Bingdang; Zhang, Shujuan

    2016-09-06

    The nontoxicity of titanium (Ti) and the potential to produce valuable photocatalysts from the final coagulated sludge constitute the main advantages of Ti-based coagulants over conventional ones. However, the low effluent pH and the too-fast hydrolysis limit the wide application of Ti-salt coagulants. Prehydrolysis, to some extent, is helpful to improve the coagulation performance of Ti-salt coagulants. However, the prehydrolyzed polytitanium chloride (PTC) still suffers from narrow applicable dose/pH range. A novel and efficient Ti-based coagulant, denoted as titanium xerogel coagulant (TXC), was successfully prepared by the sol-gel method with TiCl4 as the precursor and acetylacetone as a modifying agent. Compared with TiCl4, a PTC, and a commercial polyferric sulfate, the resulting TXC possessed a larger floc size, better settling property, and wider applicable coagulant dose/pH range. Moreover, the effluent pH after TXC coagulation was not significantly reduced, avoiding the corrosion problem sometimes caused by the low effluent pH. TXC exhibited good coagulation performance for several real wastewaters, especially for the wastewaters of low turbidity. These results demonstrate that gelation was a more effective strategy than prehydrolysis to overcome the inherent weaknesses of Ti salts as a type of promising coagulants.

  3. Effect of dairy farming system, herd, season, parity, and days in milk on modeling of the coagulation, curd firming, and syneresis of bovine milk.

    PubMed

    Bittante, G; Cipolat-Gotet, C; Malchiodi, F; Sturaro, E; Tagliapietra, F; Schiavon, S; Cecchinato, A

    2015-04-01

    The objectives of this study were to characterize the variation in curd firmness model parameters obtained from coagulating bovine milk samples, and to investigate the effects of the dairy system, season, individual farm, and factors related to individual cows (days in milk and parity). Individual milk samples (n = 1,264) were collected during the evening milking of 85 farms representing different environments and farming systems in the northeastern Italian Alps. The dairy herds were classified into 4 farming system categories: traditional system with tied animals (29 herds), modern dairy systems with traditional feeding based on hay and compound feed (30 herds), modern dairy system with total mixed ration (TMR) that included silage as a large proportion of the diet (9 herds), and modern dairy system with silage-free TMR (17 herds). Milk samples were analyzed for milk composition and coagulation properties, and parameters were modeled using curd firmness measures (CFt) collected every 15 s from a lacto-dynamographic analysis of 90 min. When compared with traditional milk coagulation properties (MCP), the curd firming measures showed greater variability and yielded a more accurate description of the milk coagulation process: the model converged for 93.1% of the milk samples, allowing estimation of 4 CFt parameters and 2 derived traits [maximum CF (CF(max)) and time from rennet addition to CF(max) (t(max))] for each sample. The milk samples whose CFt equations did not converge showed longer rennet coagulation times obtained from the model (RCT(eq)) and higher somatic cell score, and came from less-productive cows. Among the sources of variation tested for the CFt parameters, dairy herd system yielded the greatest differences for the contrast between the traditional farm and the 3 modern farms, with the latter showing earlier coagulation and greater instant syneresis rate constant (k(SR)). The use of TMR yielded a greater tmax because of a higher instant curd-firming rate constant (k(CF)). Season of sampling was found to be very important, yielding higher values during winter for all traits except k(CF) and k(SR). All CFt traits were affected by individual cow factors. For parity, milk produced by first-lactation cows showed higher k(CF) and k(SR), but delays in achieving CF(max). With respect to stage of lactation, RCT(eq) and potential asymptotic CF increased during the middle of lactation and stabilized thereafter, whereas the 2 instant rate constants presented the opposite pattern, with the lowest (k(CF)) and highest (k(SR)) values occurring in mid lactation. The new challenge offered by prolonging the test interval and individual modeling of milk technological properties allowed us to study the effects of parameters related to the environment and to individual cows. This novel strategy may be useful for investigating the genetic variability of these new coagulation traits. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Performance of coagulation tests in patients on therapeutic doses of rivaroxaban. A cross-sectional pharmacodynamic study based on peak and trough plasma levels.

    PubMed

    Francart, Suzanne J; Hawes, Emily M; Deal, Allison M; Adcock, Dorothy M; Gosselin, Robert; Jeanneret, Cheryl; Friedman, Kenneth D; Moll, Stephan

    2014-06-01

    Knowledge of anticoagulation status during rivaroxaban therapy is desirable in certain clinical situations. It was the study objective to determine coagulation tests most useful for assessing rivaroxaban's anticoagulant effect. Peak and trough blood samples from 29 patients taking rivaroxaban 20 mg daily were collected. Mass spectrometry and various coagulation assays were performed. "On-therapy range" was defined as the rivaroxaban concentrations determined by LC-MS/MS. A "misprediction percentage" was calculated based on how often results of each coagulation assay were in the normal reference range, while the rivaroxaban concentration was in the "on-therapy" range. The on-therapy range was 8.9-660 ng/ml. The misprediction percentages for prothrombin time (PT) and activated partial thromboplastin time (aPTT), using multiple reagents and coagulometers, ranged from 10%-52% and 31%-59%, respectively. PT, aPTT and activated clotting time (ACT) were insensitive to trough rivaroxaban: 59%, 62%, and 80% of samples had a normal result, respectively. Over 95% of PT and ACT values were elevated at peak. Four different rivaroxaban calibrated anti-Xa assays had R² values >0.98, demonstrating strong correlations with rivaroxaban drug levels. In conclusion, PT, aPTT and ACT are often normal in patients on therapeutic doses of rivaroxaban. However, PT and ACT may have clinical utility at higher drug plasma levels. Rivaroxaban calibrated anti-factor Xa assays can accurately identify low and high on-therapy rivaroxaban drug levels and, therefore, have superior utility in all clinical situations where assessment of anticoagulation status may be beneficial.

  5. Endoscopic monopolar coagulation of internal haemorrhoids: a surgeon's experience of the first 100 cases.

    PubMed

    Loh, W-L; Tan, S; Ngooi, M S; Ong, Z K; Ngoi, S S

    2017-01-01

    The purpose of this study was to evaluate one surgeon's initial experience with a novel technique of retroflexed endoscopic coagulation of internal haemorrhoids. Patients who presented with symptoms and signs indicating Grade II-III haemorrhoids were counselled before the procedure. Those who were assessed to require an examination of their colon, based on their age and symptoms, underwent a full colonoscopy before treatment of the haemorrhoids. After the procedure, patients were routinely prescribed nonsteroidal anti-inflammatory drugs, antibiotics and laxatives. The first 100 patients of median age 52.0 (20.8-78.5) years included 65 (65%) women. Five (5%) patients suffered from postprocedural complications, of which three (3%) were postprocedural bleeding and two (2%) were postprocedural pain, all treated conservatively. The recurrence rate was 6% at a median follow-up time of 36 (6-76) months. The median duration of follow-up was 36.5 (8.5-57.0) months. This novel technique appears to be safe and effective for the treatment of Grade II-III internal haemorrhoids, and can be incorporated seamlessly into the end of a colonoscopy for the evaluation of haematochezia. Comparative trials should be performed. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  6. Er:YAG and Nd:YAG laser in treatment of patients with contraindications of conventional dental and maxillofacial surgery

    NASA Astrophysics Data System (ADS)

    Smucler, Roman; Mazanek, Jiri

    2000-03-01

    In clinical praxis we must treat patients with some relative or absolute contraindications every day. Need of hospitalization, antibiotics, hemostyptics and complex examinations makes dentoalveolar and maxillofacial surgery in those cases quite expensive. Combination of Nd:YAG and Er:YAG laser gives us new possibilities. We can help some untreatable patients or transfer care from hospital to dental office. We have been trying to solve contraindications for laser therapy five years. In the center of our work are disorders of blood coagulation, immunity and metabolism. Nd:YAG laser is very useful in coagulation and vaporization of dental gum hypertrophies, benign and malign tumors in case of chronic anticoagulation therapy and immunosupress / in combination for example- after heart transplantation /. Special chapter is the care of patients with disseminated tumors. Er:YAG laser large solve big lesions because of minimal invasivity of course but for small benign tumors are recidives is ideal. Better and quicker healing make new standard of patients' cooperation. Generally fashionable and more comfortable laser treatment minimize need of general anesthesia. After five years we use complex laser therapy in our routine. Aim of our new work is to find ideal combination of cutting lasers to minimize classical complications of laser surgery / carbonization, long and secondary healing /.

  7. Physicochemical inactivation of Lassa, Ebola, and Marburg viruses and effect on clinical laboratory analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mitchell, S.W.; McCormick, J.B.

    1984-09-01

    Clinical specimens from patients infected with Lassa, Ebola, or Marburg virus may present a serious biohazard to laboratory workers. The authors have examined the effects of heat, alteration of pH, and gamma radiation on these viruses in human blood and on the electrolytes, enzymes, and coagulation factors measured in laboratory tests that are important in the care of an infected patient. Heating serum at 60 degrees C for 1 h reduced high titers of these viruses to noninfectious levels without altering the serum levels of glucose, blood urea nitrogen, and electrolytes. Dilution of blood in 3% acetic acid, diluent formore » a leukocyte count, inactivated all of these viruses. All of the methods tested for viral inactivation markedly altered certain serum proteins, making these methods unsuitable for samples that are to be tested for certain enzyme levels and coagulation factors.« less

  8. [Study on the difference of blood coagulation function in patients with traumatic brain injury in plain and plateau area].

    PubMed

    Sun, J; Tian, Y; Jiang, R C; Dong, X L; Wang, Y; Wu, W B; Wu, K X; Zhang, J N

    2016-10-25

    Objective: In this study, we tested platelet count (PC), prothrombin time (PT), activated partial thromboplastin time (APTT), and other indicators of coagulation function, and revealed their difference in patients with traumatic brain injury (TBI) between plain and plateau area. Base on the results, we may provide research basis for the therapy of TBI associated coagulopathy in different areas. Methods: 151 TBI patients from Tianjin Medical University General Hospital, and 74 from People's Hospital of Tibet Autonomous Region in the period from Dec 2013 to Dec 2015 were enrolled.Coagulation function, including PC, platelet distribution width (PDW), mean platelet volume (MPV), platelet - large cell ratio (P- LCR), PT, APTT, fibrinogen (FIB), and D- Dimer were tested within 8 h. The difference in patients with TBI between plain and plateau areas were compared and analyzed. Results: Compared with plain area, the PC of patients with TBI in plateau area is lower [(168±49)×10 9 /L vs (196±72)×10 9 /L, P <0.05], while PT and APTT were extended [(13.5±1.3) s vs (12.0±4.0) s, (38±4) s vs(27±6) s, P <0.01]. On the other hand, FIB increases [(3.1±1.2) g/L vs (2.6±1.0) g/L, P <0.01] and D-Dimer decreases [(3.1±3.3) μg/L vs (4.7±3.6) μg/L, P <0.01] in plateau area compared with plain area. Conclusion: Due to the people of plateau area living in hypoxia state, the coagulation function is activated for a long time.Once TBI happens, the platelets and coagulation factors may be excessive consumption, resulting in hypocoagulable state and high risk of rebleeding, while the fibrinolysis system in patients with TBI of plateau area is not activated obviously.Therefore, it should give full consideration to these differences in the treatment of patients with TBI in plateau area, instead of directly copying the standard therapy of the people in plain area.The treatment recommendations should primarily supplement coagulation materials, and antifibrinolytics may unlikely have the therapy effect.

  9. [Comparative study on promoting blood effects of Danshen-Honghua herb pair with different preparations based on chemometrics and multi-attribute comprehensive index methods].

    PubMed

    Qu, Cheng; Tang, Yu-Ping; Shi, Xu-Qin; Zhou, Gui-Sheng; Shang, Er-Xin; Shang, Li-Li; Guo, Jian-Ming; Liu, Pei; Zhao, Jing; Zhao, Bu-Chang; Duan, Jin-Ao

    2017-08-01

    To evaluate the promoting blood circulation and removing blood stasis effects of Danshen-Honghua(DH) herb pair with different preparations (alcohol, 50% alcohol and water) on blood rheology and coagulation functions in acute blood stasis rats, and optimize the best preparation method of DH based on principal component analysis(PCA), hierarchical cluster heatmap analysis and multi-attribute comprehensive index methods. Ice water bath and subcutaneous injection of adrenaline were both used to establish the acute blood stasis rat model. Then the blood stasis rats were administrated intragastrically with DH (alcohol, 50% alcohol and water) extracts. The whole blood viscosity(WBV), plasma viscosity(PV), erythrocyte sedimentation rate(ESR) and haematocrit(HCT) were tested to observe the effects of DH herb pair with different preparations and doses on hemorheology of blood stasis rats; the activated partial thromboplastin time(APTT), thrombin time(TT), prothrombin time(PT), and plasma fibrinogen(FIB) were tested to observe the effects of DH herb pair with different preparations on blood coagulation function and platelet aggregation of blood stasis rats. Then PCA, hierarchical cluster heatmap analysis and multi-attribute comprehensive index methods were all used to comprehensively evaluate the total promoting blood circulation and removing blood stasis effects of DH herb pair with different preparations. The hemorheological indexes and coagulation parameters of model group had significant differences with normal blank group. As compared with the model group, the DH herb pair with different preparations at low, middle and high doses could improve the blood hemorheology indexes and coagulation parameters in acute blood stasis rats with dose-effect relation. Based on the PCA, hierarchical cluster heatmap analysis and multi-attribute comprehensive index methods, the high dose group of 50% alcohol extract had the best effect of promoting blood circulation and removing blood stasis. Under the same dose but different preparations, 50% alcohol DH could obviously improve the hemorheology and blood coagulation function in acute blood stasis rats. These results suggested that DH herb pair with different preparations could obviously ameliorate the abnormality of hemorheology and blood coagulation function in acute blood stasis rats, and the optimized preparation of DH herb pair on promoting blood effects was 50% alcohol extract, providing scientific basis for more effective application of the DH herb pair in modern clinic medicine. Copyright© by the Chinese Pharmaceutical Association.

  10. Assessing blood coagulation status with laser speckle rheology

    PubMed Central

    Tripathi, Markandey M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2014-01-01

    We have developed and investigated a novel optical approach, Laser Speckle Rheology (LSR), to evaluate a patient’s coagulation status by measuring the viscoelastic properties of blood during coagulation. In LSR, a blood sample is illuminated with laser light and temporal speckle intensity fluctuations are measured using a high-speed CMOS camera. During blood coagulation, changes in the viscoelastic properties of the clot restrict Brownian displacements of light scattering centers within the sample, altering the rate of speckle intensity fluctuations. As a result, blood coagulation status can be measured by relating the time scale of speckle intensity fluctuations with clinically relevant coagulation metrics including clotting time and fibrinogen content. Our results report a close correlation between coagulation metrics measured using LSR and conventional coagulation results of activated partial thromboplastin time, prothrombin time and functional fibrinogen levels, creating the unique opportunity to evaluate a patient’s coagulation status in real-time at the point of care. PMID:24688816

  11. Effects of first-line anti-retroviral therapy on blood coagulation parameters of HIV-infected patients attending a tertiary hospital at Abuja, Nigeria.

    PubMed

    Nasir, I A; Owolagba, A; Ahmad, A E; Barma, M M; Musa Po, P O; Bakare, M; Ibrahim, Y; Amadu, D O

    2016-08-01

    Blood coagulation abnormalities are common in persons infected with the human immunodeficiency virus (HIV). However, few studies showed the association of these abnormalities with anti-retroviral therapy (ART). This cross-sectional study investigated the effects of ART on blood coagulation parameters of patients infected with HIV attending HIV special clinics of the University of Abuja Teaching Hospital (UATH), Gwagwalada, Abuja, Nigeria. A total of 191 patients comprising 128 HIV subjects on ART (test subjects) and 63 other HIV patients not on ART (control subjects) were included in the study. CD4+ lymphocyte counts, platelet counts, prothrombin time (PT) and partial thromboplastin time with kaolin (PTTK) of subjects were determined using flow cytometry, automated hematology analyser and Quick one-stage methods respectively. Of the total test subjects, 21 (16.4%) were CD4 lymphopaenic, and the mean CD4+ cell count for the test subjects was statistically higher than that of the control subjects (578 versus 322 cells/ mm(3)) (p = 0.014). Eight (6.3%) of test subjects had prolong PTTK, and the mean values of PT and PTTK were statistically not significant between test subjects and control subjects (p = 0.358 and p= 0.141 respectively). Eight (6.3%) of test subjects had thrombocytopaenia, the mean platelet count was significantly lower than that of the control subjects (238 versus 278.6 x 10(9)/L, p = 0.001), and also varied significantly with the duration of ART (p = 0.0086). Findings from this study revealed ART decreased platelet counts of HIV-infected individuals, but did not affect the PT and PTTK results.

  12. Detection of high-risk thrombophilia with an automated, global test: the Coagulation Inhibitor Potential assay.

    PubMed

    Réger, Barbara; Losonczy, Hajna; Nagy, Ágnes; Péterfalvi, Ágnes; Mózes, Réka; Pótó, László; Farkas, Nelli; Kovács, Gábor L; Miseta, Attila; Hussain, Alizadeh; Tóth, Orsolya

    2018-05-17

    : The diagnosis of thrombophilia is a cost-consuming and time-consuming process, as each defect should be separately investigated. The Coagulation Inhibitor Potential (CIP) assay is a promising new global test, sensitive for most of the hereditary thrombophilias, developed for manual methodology. We adapt the original method to an optical coagulation analyser. By this automation, the test will be easier, faster and more precise, and it also allows carrying out 18 measurements simultaneously. The CIP assay was performed in 126 healthy subjects and 193 patients with different types of hereditary thrombophilia conditions. Detected with conventional laboratory tests high-risk thrombophilia was present in 70 patients: deficiencies of antithrombin (AT) (n = 12), protein C (PC) (n = 14), protein S (PS) (n = 6), homozygous factor V Leiden (FVL) mutation (n = 9) and combined types (n = 29). Low-risk thrombophilia was present in 123 patients: heterozygous FVL (n = 115) and FII G2010A mutation (n = 8). Significantly lower median CIP values were found for AT-,PC-, PS deficiencies, homozygous and heterozygous FVL mutations and combined thrombophilias (P < 0.01) as compared with healthy controls. There was no significant difference between the heterozygous FIIG20210A (P = 0.669) thrombophilia group and the healthy controls. The best performance of the test was achieved at the cut-off value of 90.0 U (area: 0.981) with 96% sensitivity and 92% specificity in the high-risk thrombophilia group estimated by receiver operating characteristic analysis. The new method seems to be appropriate and reliable for the detection of AT-, PC- and PS deficiencies, homozygous FVL mutation and also for combined deficiencies. The automated CIP test is insensitive to FII G2010A mutation.

  13. Estimation of plasma fibrinogen levels based on hemoglobin, base excess and Injury Severity Score upon emergency room admission

    PubMed Central

    2013-01-01

    Introduction Fibrinogen plays a key role in hemostasis and is the first coagulation factor to reach critical levels in massively bleeding trauma patients. Consequently, rapid estimation of plasma fibrinogen (FIB) is essential upon emergency room (ER) admission, but is not part of routine coagulation monitoring in many centers. We investigated the predictive ability of the laboratory parameters hemoglobin (Hb) and base excess (BE) upon admission, as well as the Injury Severity Score (ISS), to estimate FIB in major trauma patients. Methods In this retrospective study, major trauma patients (ISS ≥16) with documented FIB analysis upon ER admission were eligible for inclusion. FIB was correlated with Hb, BE and ISS, alone and in combination, using regression analysis. Results A total of 675 patients were enrolled (median ISS 27). FIB upon admission correlated strongly with Hb, BE and ISS. Multiple regression analysis showed that Hb and BE together predicted FIB (adjusted R2 = 0.46; loge(FIB) = 3.567 + 0.223.Hb - 0.007.Hb2 + 0.044.BE), and predictive strength increased when ISS was included (adjusted R2 = 0.51; loge(FIB) = 4.188 + 0.243.Hb - 0.008.Hb2 + 0.036.BE - 0.031.ISS + 0.0003.ISS2). Of all major trauma patients admitted with Hb <12 g/dL, 74% had low (<200 mg/dL) FIB and 54% had critical (<150 mg/dL) FIB. Of patients admitted with Hb <10 g/dL, 89% had low FIB and 73% had critical FIB. These values increased to 93% and 89%, respectively, among patients with an admission Hb <8 g/dL. Sixty-six percent of patients with only a weakly negative BE (<−2 mmol/L) showed low FIB. Of patients with BE <−6 mmol/L upon admission, 81% had low FIB and 63% had critical FIB. The corresponding values for BE <−10 mmol/L were 89% and 78%, respectively. Conclusions Upon ER admission, FIB of major trauma patients shows strong correlation with rapidly obtainable, routine laboratory parameters such as Hb and BE. These two parameters might provide an insightful and rapid tool to identify major trauma patients at risk of acquired hypofibrinogenemia. Early calculation of ISS could further increase the ability to predict FIB in these patients. We propose that FIB can be estimated during the initial phase of trauma care based on bedside tests. PMID:23849249

  14. Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.

    PubMed

    Okuda, T; Baes, A U; Nishijima, W; Okada, M

    2001-03-01

    This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.

  15. Plasma temperature during methylene blue/light treatment influences virus inactivation capacity and product quality.

    PubMed

    Gravemann, U; Handke, W; Sumian, C; Alvarez, I; Reichenberg, S; Müller, T H; Seltsam, A

    2018-02-27

    Photodynamic treatment using methylene blue (MB) and visible light is in routine use for pathogen inactivation of human plasma in different countries. Ambient and product temperature conditions for human plasma during production may vary between production sites. The influence of different temperature conditions on virus inactivation capacity and plasma quality of the THERAFLEX MB-Plasma procedure was investigated in this study. Plasma units equilibrated to 5 ± 2°C, room temperature (22 ± 2°C) or 30 ± 2°C were treated with MB/light and comparatively assessed for the inactivation capacity for three different viruses, concentrations of MB and its photoproducts, activity of various plasma coagulation factors and clotting time. Reduced solubility of the MB pill was observed at 5 ± 2°C. Photocatalytic degradation of MB increased with increasing temperature, and the greatest formation of photoproducts (mainly azure B) occurred at 30 ± 2°C. Inactivation of suid herpesvirus, bovine viral diarrhoea virus and vesicular stomatitis virus was significantly lower at 5 ± 2°C than at higher temperatures. MB/light treatment affected clotting times and the activity of almost all investigated plasma proteins. Factor VIII (-17·7 ± 8·3%, 22 ± 2°C) and fibrinogen (-14·4 ± 16·4%, 22 ± 2°C) showed the highest decreases in activity. Increasing plasma temperatures resulted in greater changes in clotting time and higher losses of plasma coagulation factor activity. Temperature conditions for THERAFLEX MB-Plasma treatment must be carefully controlled to assure uniform quality of pathogen-reduced plasma in routine production. Inactivation of cooled plasma is not recommended. © 2018 International Society of Blood Transfusion.

  16. Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair

    NASA Astrophysics Data System (ADS)

    Zhao, Ming

    Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.

  17. Coagulation monitoring based on blood elastic measurement using optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Xu, Xiangqun; Zhu, Jiang; Chen, Zhongping

    2017-02-01

    Blood coagulation monitoring is important to diagnose hematological diseases and cardiovascular diseases and to predict the risk of bleeding and excessive clotting. In this study, we developed a system to dynamically monitor blood coagulation and quantitatively determine the coagulation function by blood elastic measurement. When blood forms a clot from a liquid, ultrasonic force induces a shear wave, which is detected by optical coherence tomography (OCT). The coagulation of porcine whole blood recalcified by calcium chloride is assessed using the metrics of reaction time, clot formation kinetics and maximum shear modulus. The OCE system can noninvasively monitor the blood coagulation and quantitatively determine the coagulation function.

  18. Blood coagulation profiling in patients using optical thromboelastography (OTEG) (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Tripathi, Markandey M.; Tshikudi, Diane M.; Hajjarian, Zeinab; Van Cott, Elizabeth M.; Nadkarni, Seemantini K.

    2016-02-01

    Impaired blood coagulation is often associated with increased postoperative mortality and morbidity in cardiovascular patients. The capability for blood coagulation profiling rapidly at the bedside will enable the timely detection of coagulation defects and open the opportunity for tailoring therapy to correct specific coagulation deficits Optical Thromboelastography (OTEG), is an optical approach to quantify blood coagulation status within minutes using a few drops of whole blood. The goal of the current study is to evaluate the diagnostic accuracy of OTEG for rapid coagulation profiling in patients. In OTEG, temporal laser speckle intensity fluctuations from a drop of clotting blood are measured using a CMOS camera. To quantify coagulation status, the speckle intensity autocorrelation function is measured, the mean square displacement of scattering particles is extracted, and viscoelastic modulus (G), during coagulation is measured via the generalized Stokes-Einstein relation. By quantifying time-resolved changes in G, the coagulation parameters, reaction time (R), clot progression time (K), clot progression rate (Angle), and maximum clot strength (MA) are derived. In this study, the above coagulation parameters were measured using OTEG in 269 patients and compared with standard mechanical Thromboelastography (TEG). Our results showed a strong correlation between OTEG and TEG measurements for all parameters: R-time (R=0.80, p<0.001), clotting time (R=0.78, p<0.001), Angle (R=0.58, p<0.001), and MA (R=0.60, p<0.001). These results demonstrate the unique capability of OTEG for rapid quantification of blood coagulation status to potentially improve clinical capability for identifying impaired coagulation in cardiovascular patients at the point of care.

  19. A prospective multicenter cohort study of the association between global tissue hypoxia and coagulation abnormalities during early sepsis resuscitation.

    PubMed

    Trzeciak, Stephen; Jones, Alan E; Shapiro, Nathan I; Pusateri, Anthony E; Arnold, Ryan C; Rizzuto, Michael; Arora, Tanisha; Parrillo, Joseph E; Dellinger, R Phillip

    2010-04-01

    Coagulation activation is an integral part of sepsis pathogenesis. Experimental data suggest that endothelial exposure to hypoxia activates coagulation. We aimed to test the hypothesis that the quantity of exposure to global tissue hypoxia is associated with the degree of coagulation activation during early sepsis resuscitation. Prospective, multicenter cohort study. Emergency department and intensive care unit of three academic hospitals. Inclusion criteria were age older than 17, acute infection with two or more signs of systemic inflammation, hypotension despite fluid challenge (or lactate >4 mM), and continuous central venous oxygen saturation (Scvo2) monitoring for quantitative resuscitation. Exclusion criteria were anticoagulant or blood product administration. We recorded central venous oxygen saturation continuously for 0 to 6 hrs of resuscitation and calculated the area under the curve for central venous oxygen saturation <70%. We defined hypoxia exposure as exceeding the median area under the curve for the entire cohort. At 0, 6, and 24 hrs, we measured conventional coagulation biomarkers plus thrombin-antithrombin complex, plasmin-antiplasmin complex, tissue plasminogen activator, plasminogen activator inhibitor-1, protein C, antithrombin, and endothelial markers (E-selectin, intracellular adhesion molecule-1, thrombomodulin). We compared changes during 0 to 6 hrs and 0 to 24 hrs in biomarkers between hypoxia exposure and nonexposure groups. We enrolled 40 patients (60% requiring vasopressors; 30% mortality). We found that exposure to hypoxia alone was not associated with a significant degree of coagulation activation. However, in secondary analyses we found that exposure to arterial hypotension induced E-selectin and thrombin-antithrombin complex, whereas concomitant exposure to both hypotension and hypoxia was associated with amplification of E-selectin and thrombomodulin, and a reduction in protein C. In this sample of patients undergoing quantitative resuscitation for sepsis, we found that exposure to global tissue hypoxia (as quantified by low central venous oxygen saturation) was not associated with major coagulation activation. Further investigation to elucidate the clinical factors that trigger or intensify the procoagulant response to sepsis is warranted.

  20. 21 CFR 864.7300 - Fibrin monomer paracoagulation test.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...

  1. 21 CFR 864.7300 - Fibrin monomer paracoagulation test.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...

  2. 21 CFR 864.7300 - Fibrin monomer paracoagulation test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...

  3. 21 CFR 864.7300 - Fibrin monomer paracoagulation test.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...

  4. 21 CFR 864.7300 - Fibrin monomer paracoagulation test.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... clotting within a blood vessel) or in the differential diagnosis between disseminated intravascular coagulation and primary fibrinolysis (dissolution of the fibrin in a blood clot). (b) Classification. Class II...

  5. 21 CFR 864.7290 - Factor deficiency test.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... state (a person carrying both a recessive gene for a coagulation factor deficiency such as hemophilia and the corresponding normal gene). (b) Classification. Class II (performance standards). [45 FR 60613...

  6. Thromboelastography in Dogs with Chronic Hepatopathies.

    PubMed

    Fry, W; Lester, C; Etedali, N M; Shaw, S; DeLaforcade, A; Webster, C R L

    2017-03-01

    The coagulation status of dogs with liver disease is difficult to predict using conventional coagulation testing. To evaluate thromboelastography (TEG) results and associations with conventional coagulation results and indicators of disease severity and prognosis in dogs with chronic hepatopathies (CH). Twenty-one client-owned dogs. Dogs with CH were prospectively (10 dogs) and retrospectively (11 dogs) enrolled from 2008 to 2014. Kaolin-activated TEG was performed and compared with reference intervals by t-tests or Mann-Whitney tests. Correlation coefficients for TEG results and conventional coagulation and clinicopathologic results were determined. Significance was set at P < .05. Dogs with CH had significant increases in R (5.30 min vs 4.33 min), K (3.77 min vs 2.11 min), and LY30 (4.77% vs 0.68%) and decreased angles (55.3° vs 62.4°). G value defined 9 of 21, 7 of 21, and 5 of 21 dogs as normocoagulable, hypercoagulable, and hypocoagulable, respectively. G and MA were correlated with fibrinogen (r = 0.68, 0.83), prothrombin time (PT; r = -0.51, -0.53), and activated partial thromboplastin time (aPTT; r = -0.50, -0.50). K was correlated with PT (r = 0.75) and protein C activity (r = -0.92). Angle was correlated with aPTT (r = -0.63). Clinical score was correlated with PT (r = 0.60), MA (r = -0.53), and R (r = -0.47). Dogs with hyperfibrinolysis (LY30 > 3.04%; 5 of 21) had significantly higher serum transaminase activities. Dogs with portal hypertension had significantly lower G, MA, and angle and prolonged, K, R, and PT. Dogs with CH have variable TEG results. Negative prognostic indicators in CH correlate with hypocoagulable parameters on TEG. Hyperfibrinolysis in dogs with CH is associated with high disease activity. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  7. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania.

    PubMed

    Coyle, Catelyn; Kwakwa, Helena

    2016-01-01

    Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012-August 31, 2013) and after (September 1, 2013-May 31, 2014) implementation of the dual-routine HCV/HIV testing model. A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care.

  8. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania

    PubMed Central

    Kwakwa, Helena

    2016-01-01

    Objective Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. Methods National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012–August 31, 2013) and after (September 1, 2013–May 31, 2014) implementation of the dual-routine HCV/HIV testing model. Results A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. Conclusion The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care. PMID:26862229

  9. [The activity of formaldehyde, glutardialdehyde, peracetic acid, chloramine T (N-chlor-4-toluolsulfonamide), m-cresol, ethanol and benzyldimethyldodecylammonium bromide against bacteria which are found in coagulated blood. (Model studies for chemical disinfection of instruments].

    PubMed

    Spicher, G; Peters, J

    1991-05-01

    The experiments were performed using frosted glass as carrier with its surface being contaminated with whole blood containing Staphylococcus aureus as test organism. At the time of sampling, a heparin preparation was added to the blood to prevent premature coagulation. After addition of the staphylococci, coagulation was initiated by means of a heparin antagonist. 10, 25, 50, 100, and 150 microliters, respectively, of the blood were homogeneously spread on rectangular test areas of 10 x 20 mm. After the blood had coagulated, each of the test objects was placed in 15 ml of the solution (20 degrees C) containing the active ingredient tested for 60 min. After that, the test objects were removed from the disinfectant and, in order to inactivate any adhering active components, treated with a neutralizing solution of suitable composition. The number of viable germs (colony-forming units) was determined quantitatively. The blood samples were ground together with quartz sand. Aliquots of the diluted suspensions were mixed with molten agar medium. The plates then were incubated at 37 degrees C over a period of 14 days. The relative number of viable germs (N/No) per test object was calculated from the number of colonies. Plotting of the microbicidal effects obtained (log N/No] versus the concentration of the active substance (see Figs. 1-3) yielded curves differing in some characteristics as e.g. curvature, slope of the lower curve section (log N/No). less than -3), concentration range according to the layer thickness of the contamination. To visualize the reduction of the efficacy of the respective disinfectants caused by blood, the concentrations of active components were determined which are necessary to achieve a microbicidal effect of log (N/No) = -4. These concentrations were plotted versus the amounts of blood per test area (Fig. 4). The resulting curve for formaldehyde was slightly U-shaped. With a raising amount of blood, the concentration required slightly decreased in the beginning and increased again from an amount of ca. 100 microliter blood per test area. For all other active substances, the required concentration of these substances increased with the amount of blood used. The curve obtained for ethanol exhibited the lowest slope. The slope of the curves increased in the following order: ethanol, m-cresol, peracetic acid, chloramine T, glutardialdehyde, benzyldimethyldodecylammoniumbromide. The curves for chloramine T and glutardialdehyde nearly paralleled each other.(ABSTRACT TRUNCATED AT 400 WORDS)

  10. Solid colloidal optical wavelength filter

    DOEpatents

    Alvarez, Joseph L.

    1992-01-01

    A solid colloidal optical wavelength filter includes a suspension of spheal particles dispersed in a coagulable medium such as a setting plastic. The filter is formed by suspending spherical particles in a coagulable medium; agitating the particles and coagulable medium to produce an emulsion of particles suspended in the coagulable medium; and allowing the coagulable medium and suspended emulsion of particles to cool.

  11. Application of Cox model in coagulation function in patients with primary liver cancer.

    PubMed

    Guo, Xuan; Chen, Mingwei; Ding, Li; Zhao, Shan; Wang, Yuefei; Kang, Qinjiong; Liu, Yi

    2011-01-01

    To analyze the distribution of coagulation parameters in patients with primary liver cancer; explore the relationship between clinical staging, survival, and coagulation parameters by using Coxproportional hazard model; and provide a parameter for clinical management and prognosis. Coagulation parameters were evaluated in 228 patients with primary liver cancer, 52 patients with common liver disease, and 52 normal healthy controls. The relationship between primary livercancer staging and coagulation parameters wasanalyzed. Follow-up examinations were performed. The Cox proportional hazard model was used to analyze the relationship between coagulationparameters and survival. The changes in the coagulation parameters in patients with primary liver cancer were significantly different from those in normal controls. The effect of the disease on coagulation function became more obvious as the severity of liver cancer increased (p<0.05). The levels of D-dimer, fibrinogen degradation products (FDP), fibrinogen (FIB), and platelets (PLT) were negatively correlated with the long-term survival of patients with advanced liver cancer. The stages of primary liver cancer are associated with coagulation parameters. Coagulation parameters are related to survival and risk factors. Monitoring of coagulation parameters may help ensure better surveillance and treatment for liver cancer patients.

  12. Monopolar soft-mode coagulation using hemostatic forceps for peptic ulcer bleeding.

    PubMed

    Yamasaki, Yasushi; Takenaka, Ryuta; Nunoue, Tomokazu; Kono, Yoshiyasu; Takemoto, Koji; Taira, Akihiko; Tsugeno, Hirofumi; Fujiki, Shigeatsu

    2014-01-01

    Upper gastrointestinal hemorrhage from bleeding peptic ulcer is sometimes difficult to treat by conventional endoscopic methods. Recently, monopolar electrocoagulation using a soft-coagulation system and hemostatic forceps (soft coagulation) has been used to prevent bleeding during endoscopic submucosal dissection. The aim of this study was to assess the safety and efficacy of soft coagulation in the treatment of bleeding peptic ulcer. A total of 39 patients with peptic ulcers were treated using soft coagulation at our hospital between January 2005 and March 2010. Emergency treatment employed an ERBE soft-mode coagulation system using hemostatic forceps. Second-look endoscopy was performed to evaluate the efficacy of prior therapy. Initial hemostasis was defined as accomplished by soft coagulation, with or without other endoscopic therapy prior to soft coagulation. The rate of initial hemostasis, rebleeding, and ultimate hemostasis were retrospectively analyzed. The study subjects were 31 men and 8 women with a mean age of 68.3±13.7 years, with 29 gastric ulcers and 10 duodenal ulcers. Initial hemostasis was achieved in 37 patients (95%). During follow-up, bleeding recurred in two patients, who were retreated with soft coagulation. The monopolar soft coagulation is feasible and safe for treating bleeding peptic ulcers.

  13. Direct observation on the Brownian coagulation of PSL particles through optical microscope in the regime near critical coagulation concentration (CCC).

    PubMed

    Fukasawa, Tomonori; Adachi, Yasuhisa

    2010-04-15

    Microscopic monitoring of floc structure, floc size distribution and the rate of coagulation was carried out for Brownian coagulation of PSL particles. Experiments were designed for the condition of salt concentration that is slightly below critical coagulation concentration (CCC). The density of the solvent was controlled by using deuterium oxide (D(2)O) to avoid sedimentation. Results are summarized as follows: (i) Near CCC, floc restructuring from the beginning stage of coagulation was evidenced, i.e., the ratio of linear triplet is found to be remarkably reduced as compared with the result obtained for the case of rapid coagulation which was implemented under sufficiently high salt concentration. (ii) The increase of fractal dimension from 1.8 in the case of rapid coagulation to 2.2 was confirmed by the analysis of mass balance using size distribution of flocs. This increment resulted in the decrease of effective excluded volume of flocs. (iii) The rate of coagulation was constant until later stage. This result contrasts to the result of rapid coagulation [T. Fukasawa, Y. Adachi, J. Colloid Interface Sci. 304 (2006) 115]. 2010 Elsevier Inc. All rights reserved.

  14. Sepsis-Induced Coagulation in the Baboon Lung Is Associated with Decreased Tissue Factor Pathway Inhibitor

    PubMed Central

    Tang, Haiwang; Ivanciu, Lacramioara; Popescu, Narcis; Peer, Glenn; Hack, Erik; Lupu, Cristina; Taylor, Fletcher B.; Lupu, Florea

    2007-01-01

    Increased tissue factor (TF)-dependent procoagulant activity in sepsis may be partly due to decreased expression or function of tissue factor pathway inhibitor (TFPI). To test this hypothesis, baboons were infused with live Escherichia coli and sacrificed after 2, 8, or 24 hours. Confocal and electron microscopy revealed increased leukocyte infiltration and fibrin deposition in the intravascular and interstitial compartments. Large amounts of TF were detected by immunostaining in leukocytes and platelet-rich microthrombi. TF induction was documented by quantitative reverse transcriptase-polymerase chain reaction, enzyme-linked immunosorbent assay, and coagulation assays. Lung-associated TFPI antigen and mRNA decreased during sepsis, and TFPI activity diminished abruptly at 2 hours. Blocking antibodies against TFPI increased fibrin deposition in septic baboon lungs, suggesting that TF-dependent coagulation might be aggravated by reduced endothelial TFPI. Decreased TFPI activity coincided with the release of tissue plasminogen activator and the peak of plasmin generation, suggesting that TFPI could undergo proteolytic inactivation by plasmin. Enhanced plasmin produced in septic baboons by infusion of blocking antibodies against plasminogen activator inhibitor-1 led to decreased lung-associated TFPI and unforeseen massive fibrin deposition. We conclude that activation of TF-driven coagulation not adequately countered by TFPI may underlie the widespread thrombotic complications of sepsis. PMID:17640967

  15. Coagulant plus ballast technique provides a rapid mitigation of cyanobacterial nuisance

    PubMed Central

    de Magalhães, Leonardo; Miranda, Marcela; Mucci, Maíra; van Oosterhout, Frank; Huszar, Vera L. M.; Marinho, Marcelo M.; Lima, Eduardo R. A.; Lürling, Miquel

    2017-01-01

    Cyanobacteria blooms are a risk to environmental health and public safety due to the potent toxins certain cyanobacteria can produce. These nuisance organisms can be removed from water bodies by biomass flocculation and sedimentation. Here, we studied the efficacy of combinations of a low dose coagulant (poly-aluminium chloride—PAC—or chitosan) with different ballast compounds (red soil, bauxite, gravel, aluminium modified zeolite and lanthanum modified bentonite) to remove cyanobacterial biomass from water collected in Funil Reservoir (Brazil). We tested the effect of different cyanobacterial biomass concentrations on removal efficiency. We also examined if zeta potential was altered by treatments. Addition of low doses of PAC and chitosan (1–8 mg Al L-1) to the cyanobacterial suspensions caused flock formation, but did not settle the cyanobacteria. When those low dose coagulants were combined with ballast, effective settling in a dose-dependent way up to 99.7% removal of the flocks could be achieved without any effect on the zeta potential and thus without potential membrane damage. Removal efficacy was influenced by the cyanobacterial biomass and at higher biomass more ballast was needed to achieve good removal. The combined coagulant-ballast technique provides a promising alternative to algaecides in lakes, ponds and reservoirs. PMID:28598977

  16. The use of a natural coagulant (Opuntia ficus-indica) in the removal for organic materials of textile effluents.

    PubMed

    de Souza, Maísa Tatiane Ferreira; Ambrosio, Elizangela; de Almeida, Cibele Andrade; de Souza Freitas, Thábata Karoliny Formicoli; Santos, Lídia Brizola; de Cinque Almeida, Vitor; Garcia, Juliana Carla

    2014-08-01

    The goal of this study was to investigate the activity of the coagulant extracted from the cactus Opuntia ficus-indica (OFI) in the process of coagulation/flocculation of textile effluents. Preliminary tests of a kaolinite suspension achieved maximum turbidity removal of 95 % using an NaCl extraction solution. Optimization assays were conducted with actual effluents using the response surface methodology (RSM) based on the Box-Behnken experimental design. The responses of the variables FeCl3, dosage, cactus dosage, and pH in the removal of COD and turbidity from both effluents were investigated. The optimum conditions determined for jeans washing laundry effluent were the following: FeCl3 160 mg L(-1), cactus dosage 2.60 mg L(-1), and pH 5.0. For the fabric dyeing effluent, the optimum conditions were the following: FeCl3 640 mg L(-1), cactus dosage 160 mg L(-1), and pH 6.0. Investigation of the effects of the storage time and temperature of the cactus O. ficus-indica showed that coagulation efficiency was not significantly affected for storage at room temperature for up to 4 days.

  17. Innovative physico-chemical treatment of wastewater incorporating Moringa oleifera seed coagulant.

    PubMed

    Bhuptawat, Hitendra; Folkard, G K; Chaudhari, Sanjeev

    2007-04-02

    Moringa oleifera is a pan tropical, multipurpose tree whose seeds contain a high quality edible oil (up to 40% by weight) and water soluble proteins that act as effective coagulants for water and wastewater treatment. The use of this natural coagulant material has not yet realised its potential. A water extract of M. oleifera seed was applied to a wastewater treatment sequence comprising coagulation-flocculation-sedimentation-sand filtration. The study was laboratory based using an actual wastewater. Overall COD removals of 50% were achieved at both 50 and 100mg/l M. oleifera doses. When 50 and 100mg/l seed doses were applied in combination with 10mg/l of alum, COD removal increased to 58 and 64%, respectively. The majority of COD removal occurred during the filtration process. In the tests incorporating alum, sludge generation and filter head loss increased by factors of 3 and 2, respectively. These encouraging treatment results indicate that this may be the first treatment application that can move to large scale adoption. The simple water extract may be obtained at minimal cost from the presscake residue remaining after oil extraction from the seed. The regulatory compliance issues of adopting 'new materials' for wastewater treatment are significantly less stringent than those applying to the production of potable water.

  18. Calpastatin Controls Polymicrobial Sepsis by Limiting Procoagulant Microparticle Release

    PubMed Central

    Gerotziafas, Grigoris; Byrnes, Colleen; Hu, Xuzhen; Perez, Joelle; Lévi, Charlène; Placier, Sandrine; Letavernier, Emmanuel; Leelahavanichkul, Asada; Haymann, Jean-philippe; Elalamy, Ismail; Miller, Jeffrey L.; Star, Robert A.; Yuen, Peter S. T.; Baud, Laurent

    2012-01-01

    Rationale: Sepsis, a leading cause of death worldwide, involves widespread activation of inflammation, massive activation of coagulation, and lymphocyte apoptosis. Calpains, calcium-activated cysteine proteases, have been shown to increase inflammatory reactions and lymphocyte apoptosis. Moreover, calpain plays an essential role in microparticle release. Objectives: We investigated the contribution of calpain in eliciting tissue damage during sepsis. Methods: To test our hypothesis, we induced polymicrobial sepsis by cecal ligation and puncture in wild-type (WT) mice and transgenic mice expressing high levels of calpastatin, a calpain-specific inhibitor. Measurements and Main Results: In WT mice, calpain activity increased transiently peaking at 6 hours after cecal ligation and puncture surgery. Calpastatin overexpression improved survival, organ dysfunction (including lung, kidney, and liver damage), and lymphocyte apoptosis. It decreased the sepsis-induced systemic proinflammatory response and disseminated intravascular coagulation, by reducing the number of procoagulant circulating microparticles and therefore delaying thrombin generation. The deleterious effect of microparticles in this model was confirmed by transferring microparticles from septic WT to septic transgenic mice, worsening their survival and coagulopathy. Conclusions: These results demonstrate an important role of the calpain/calpastatin system in coagulation/inflammation pathways during sepsis, because calpain inhibition is associated with less severe disseminated intravascular coagulation and better overall outcomes in sepsis. PMID:22268136

  19. Toward an understanding of the turbidity measurement of heterocoagulation rate constants of dispersions containing particles of different sizes.

    PubMed

    Liu, Jie; Xu, Shenghua; Sun, Zhiwei

    2007-11-06

    Our previous studies have shown that the determination of coagulation rate constants by turbidity measurement becomes impossible for a certain operating wavelength (that is, its blind point) because at this wavelength the change in the turbidity of a dispersion completely loses its response to the coagulation process. Therefore, performing the turbidity measurement in the wavelength range near the blind point should be avoided. In this article, we demonstrate that the turbidity measurement of the rate constant for coagulation of a binary dispersion containing particles of two different sizes (heterocoagulation) presents special difficulties because the blind point shifts with not only particle size but also with the component fraction. Some important aspects of the turbidity measurement for the heterocoagulation rate constant are discussed and experimentally tested. It is emphasized that the T-matrix method can be used to correctly evaluate extinction cross sections of doublets formed during the heterocoagulation process, which is the key data determining the rate constant from the turbidity measurement, and choosing the appropriate operating wavelength and component fraction are important to achieving a more accurate rate constant. Finally, a simple scheme in experimentally determining the sensitivity of the turbidity changes with coagulation over a wavelength range is proposed.

  20. Examination of the physical properties of Microcystis aeruginosa flocs produced on coagulation with metal salts.

    PubMed

    Gonzalez-Torres, A; Putnam, J; Jefferson, B; Stuetz, R M; Henderson, R K

    2014-09-01

    Coagulation-flocculation (C-F) is a key barrier to cyanobacterial and algal cell infiltration in water treatment plants during seasonal blooms. However, the resultant cell floc properties, in terms of size, strength and density, which dominate under different coagulation conditions and govern cell removal, are not well understood. This paper investigated the floc properties produced during C-F of the cyanobacterium, Microcystis aeruginosa, under low and high doses of aluminium sulphate and ferric chloride coagulants and at different pH values, so as to promote charge neutralisation (CN) and sweep flocculation (SF) dominant conditions (or a combination of these). It was demonstrated that application of ferric chloride produced larger flocs that resulted in higher cell removal during jar testing. These flocs were also larger than those observed for natural organic matter (NOM) and kaolin, suggesting a role of algogenic organic matter (AOM) as an inherent bioflocculant. Under SF conditions, stronger flocs were produced; however, these had lower capacity for size recovery after exposure to high shear. Analysis of particle size distribution demonstrated that large scale fragmentation followed by erosion dominated for CN while erosion dominated under SF conditions. Overall, marked differences were observed dependent on the coagulation regime imposed that have implications for improving robustness of cell removal by downstream separation processes. While the cyanobacterium, M. aeruginosa, appeared to share general floc characteristics commonly observed for NOM and kaolin flocs, there were distinct differences in terms of size and strength, which may be attributed to AOM. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Effects on fibrinogen, fibrin, and blood coagulation of proteolytic extracts from fruits of Pseudananas macrodontes, Bromelia balansae, and B. hieronymi (Bromeliaceae) in comparison with bromelain.

    PubMed

    Errasti, María E; Prospitti, Anabela; Viana, Carolina A; Gonzalez, Mariana M; Ramos, Márcio V; Rotelli, Alejandra E; Caffini, Néstor O

    2016-06-01

    Extracts rich in cysteine proteases obtained from fruits of Pseudananas macrodontes (Pm), Bromelia balansae (Bb), and B. hieronymi (Bh) have previously shown an anti-inflammatory effect on animal models. Given the close relationship between hemostasis and inflammation, it is attractive to investigate therapeutic agents capable of modulating both systems. The aim of this work was to study the effect of Pm, Bb, and Bh on fibrin(ogen) and blood coagulation compared with stem bromelain (Bro). Action on fibrinogen was electrophoretically and spectrophotometrically evaluated, fibrinolytic activity was measured both electrophoretically and by the fibrin plate assay, and the effect on blood coagulation was studied by conventional coagulation tests (PT and APPT). All extracts showed the same proteolytic preference for fibrinogen subunits, that is Aα > Bβ, whereas γ was partially hydrolyzed by 100-fold concentration increase. Unlike Bro, cysteine proteases of Pm, Bb, and Bh increased absorbance at 540 nm of fibrinogen solution, suggesting thrombin-like activity, which was time-dependent and reached maximum values at lower concentration. All extracts showed the same proteolytic preference for fibrin subunits; however Pm, Bb, and Bh showed lower fibrinolytic activity than Bro at the assayed concentrations. Although Bb acted only as anticoagulant, Pm, Bh, and unexpectedly Bro showed dual action on blood coagulation: at low concentration showed procoagulant effect and at high concentration anticoagulant effect. Results reveal new plant species as potential sources of pharmacological agents for the treatment of a wide range of hemostatic disorders as well as to wound healing.

  2. A comparison of the efficacy of organic and mixed-organic polymers with polyaluminium chloride in chemically assisted primary sedimentation (CAPS).

    PubMed

    De Feo, G; Galasso, M; Landi, R; Donnarumma, A; De Gisi, S

    2013-01-01

    CAPS is the acronym for chemically assisted primary sedimentation, which consists of adding chemicals to raw urban wastewater to increase the efficacy of coagulation, flocculation and sedimentation. The principal benefits of CAPS are: upgrading of urban wastewater treatment plants; increasing efficacy of primary sedimentation; and the major production of energy from the anaerobic digestion of primary sludge. Metal coagulants are usually used because they are both effective and cheap, but they can cause damage to the biological processes of anaerobic digestion. Generally, biodegradable compounds do not have these drawbacks, but they are comparatively more expensive. Both metal coagulants and biodegradable compounds have preferential and penalizing properties in terms of CAPS application. The problem can be solved by means of a multi-criteria analysis. For this purpose, a series of tests was performed in order to compare the efficacy of several organic and mixed-organic polymers with that of polyaluminium chloride (PACl) under specific conditions. The multi-criteria analysis was carried out coupling the simple additive weighting method with the paired comparison technique as a tool to evaluate the criteria priorities. Five criteria with the following priorities were used: chemical oxygen demand (COD) removal > turbidity, SV60 > coagulant dose, and coagulant cost. The PACl was the best alternative in 70% of the cases. The CAPS process using PACl made it possible to obtain an average COD removal of 68% compared with 38% obtained, on average, with natural sedimentation and 61% obtained, on average, with the best PACl alternatives (cationic polyacrylamide, natural cationic polymer, dicyandiamide resin).

  3. Use of grape seed and its natural polyphenol extracts as a natural organic coagulant for removal of cationic dyes.

    PubMed

    Jeon, Jong-Rok; Kim, Eun-Ju; Kim, Young-Mo; Murugesan, Kumarasamy; Kim, Jae-Hwan; Chang, Yoon-Seok

    2009-11-01

    Natural organic coagulants (NOCs) such as chitosan and Moringa oleifera seeds have been extensively characterized for potential application in water treatment as an alternative to metal-based coagulants. However, the action of both chitosan and M. oleifera seeds is mainly restricted to anionic organic pollutants because of their cationic functional groups affording poor cationic pollutant coagulation by electrostatic repulsion. In this study, we employed ethanolic grape seed extract (GSE) and grape seed-derived polyphenols such as tannic acid and catechin in an effort to find novel NOCs showing stable anionic forms for removal of cationic organic pollutants. The target substances tested were malachite green (MG) and crystal violet (CV), both mutagenic cationic dyes. Polyphenol treatment induced fast decolorization followed by gradual floc formation concomitant with red or blue shifts in maximum absorbance wavelengths of the cationic dyes. Liquid chromatography analysis of flocs formed by polyphenols directly showed that initial supramolecular complexes attributed mainly to electrostatic attraction between polyphenol hydroxyphenyl groups and cationic dyes further progressed into stronger aggregates, leading to precipitation of dye-polyphenol complexes. Consistent with the results obtained using catechin and tannic acid, use of GSE also resulted in effective decolorization and coagulation of soluble MG and CV in aqueous solutions. Screening of several organic GSE components for NOC activity strongly suggested that natural polyphenols are the main organic ingredients causing MG and CV removal via gradual floc formation. The treatment by natural polyphenols and GSE decreased toxicity of MG- or CV-contaminated water.

  4. Surface-mediated molecular events in material-induced blood-plasma coagulation

    NASA Astrophysics Data System (ADS)

    Chatterjee, Kaushik

    Coagulation and thrombosis persist as major impediments associated with the use of blood-contacting medical devices. We are investigating the molecular mechanism underlying material-induced blood-plasma coagulation focusing on the role of the surface as a step towards prospective development of improved hemocompatible biomaterials. A classic observation in hematology is that blood/blood-plasma in contact with clean glass surface clots faster than when in contact with many plastic surfaces. The traditional biochemical theory explaining the underlying molecular mechanism suggests that hydrophilic surfaces, like that of glass, are specific activators of the coagulation cascade because of the negatively-charged groups on the surface. Hydrophobic surfaces are poor procoagulants or essentially "benign" because they lack anionic groups. Further, these negatively-charged surfaces are believed to not only activate blood factor XII (FXII), the key protein in contact activation, but also play a cofactor role in the amplification and propagation reactions that ultimately lead to clot formation. In sharp contrast to the traditional theory, our investigations indicate a need for a paradigm shift in the proposed sequence of contact activation events to incorporate the role of protein adsorption at the material surfaces. These studies have lead to the central hypothesis for this work proposing that protein adsorption to hydrophobic surfaces attenuates the contact activation reactions so that poorly-adsorbent hydrophilic surfaces appear to be stronger procoagulants relative to hydrophobic surfaces. Our preliminary studies measuring the plasma coagulation response of activated FXII (FXIIa) on different model surfaces suggested that the material did not play a cofactor role in the processing of this enzyme dose through the coagulation pathway. Therefore, we focused our efforts on studying the mechanism of initial production of enzyme at the procoagulant surface. Calculations for the amounts of FXIIa generated at material surfaces in plasma using a mathematical model for measured coagulation responses indicate that the relative contributions of the individual pathways of enzyme generation are similar at both hydrophilic and hydrophobic surfaces, only the amounts of enzyme generated scale with surface energy and area of the activating surface. Further, from direct measurement of enzyme activation at test surfaces we observed that contact activation reactions are not specific to negatively-charged hydrophilic surfaces. Rather, the molecular interactions are attenuated at hydrophobic surfaces due to protein adsorption so that poorly-adsorbent hydrophilic surfaces exhibit an apparent specificity for contact activation reactions. Preliminary studies were preformed to assay the plasma coagulation response to low-fouling surfaces prepared by either grafting poly(ethylene glycol) chains or using zwitterions. Results indicate that poly(ethylene glycol)-modified surfaces are significantly weaker procoagulants than surfaces containing zwitterions underscoring a need to specifically evaluate the coagulation response despite similarities in observed protein adsorption to both surfaces. In summary, our studies demonstrate a need to incorporate protein-adsorption competition at procoagulant surfaces into the mechanism of contact activation to account for the observed moderation of FXII activation by blood proteins unrelated to the plasma coagulation cascade.

  5. Evaluation of analgesic, anti-inflammatory, anti-depressant and anti-coagulant properties of Lactuca sativa (CV. Grand Rapids) plant tissues and cell suspension in rats.

    PubMed

    Ismail, Hammad; Mirza, Bushra

    2015-06-27

    Lactuca sativa (lettuce) has been traditionally used for relieving pain, inflammation, stomach problems including indigestion and lack of appetite. Moreover, the therapeutic significance of L. sativa includes its anticonvulsant, sedative-hypnotic and antioxidant properties. In the present study, the MC (methanol and chloroform; 1:1) and aqueous extracts of seed and leaf along with cell suspension exudate were prepared. These extracts were explored for their analgesic, anti-inflammatory, antidepressant and anticoagulant effects by hot plate analgesic assay; carrageenan induced hind paw edema test, forced swimming test and capillary method for blood clotting respectively in a rat model. The results were analyzed using one-way Analysis of Variance (ANOVA) followed by Turkey multiple comparison test. Interestingly, the extracts and the cell suspension exudate showed dual inhibition by reducing pain and inflammation. The results indicated that the aqueous extracts of leaf exhibited highest analgesic and anti-inflammatory activities followed by leaf MC, cell suspension exudate, seed aqueous and seed MC extracts. The current findings show that aqueous and MC extracts of seed have the least immobility time in the forced swimming test, which could act as an anti-depressant on the central nervous system. The leaf extracts and cell suspension exudate also expressed moderate anti-depressant activities. In anticoagulant assay, the coagulation time of aspirin (positive control) and MC extract of leaf was comparable, suggesting strong anti-coagulant effect. Additionally, no abnormal behavior or lethality was observed in any animal tested. Taken together, L. sativa can potentially act as a strong herbal drug due to its multiple pharmaceutical effects and is therefore of interest in drug discovery and development of formulations.

  6. In situ coagulation versus pre-coagulation for gravity-driven membrane bioreactor during decentralized sewage treatment: Permeability stabilization, fouling layer formation and biological activity.

    PubMed

    Ding, An; Wang, Jinlong; Lin, Dachao; Tang, Xiaobin; Cheng, Xiaoxiang; Li, Guibai; Ren, Nanqi; Liang, Heng

    2017-12-01

    Gravity-driven membrane filtration systems are promising for decentralized sewage treatment due to their low energy consumption and low maintenance. However, the low stable permeability/flux is currently limiting their wider application. With the ultimate goal of increasing permeability, the aim of this study was to evaluate the effect of coagulation (in situ coagulation and pre-coagulation) on the performance of a gravity-driven membrane bioreactor (GDMBR) during treatment of synthetic sewage. Results show that in situ coagulation significantly increased permeability (more than two-fold); however, no stabilization of permeability occurred over the whole operation, when non-coagulated and pre-coagulated reactors were compared. The high permeability observed was attributed to the accumulated aluminium floc in the reactor, which prevented formation of fluorescent microbial metabolites (aromatic and tryptophan proteins, as well as fulvic acids), and further avoided membrane pore blocking. In addition, the surface porosity of the fouling layer was improved (from 11.2% to 32.4% for non-coagulated and in situ coagulated reactors). The unstable permeability was possibly associated with lower biological processes within the fouling layer. These might include lower adenosine triphosphate (ATP) content and lower fluorescent metabolites from the extracellular polymeric substances (EPS) caused by the accumulated Al (compared with the control). On the other hand, pre-coagulation improved the level of stable permeability compared with the control (80 versus 40 L/m 2 h bar), mainly because pre-coagulation decreased the EPS content and also maintained high ATP content of the fouling layer. In addition, both coagulation processes reduced the total filtration resistance, mainly the hydraulically reversible resistance and cake layer resistance, which could lower the cleaning frequency. Overall, coagulation could greatly increase the removal efficiency and improve the GDMBR permeability, which would make the process suitable for decentralized wastewater treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Influence of vegetable coagulant and ripening time on the lipolytic and sensory profile of cheeses made with raw goat milk from Canary breeds.

    PubMed

    Rincón, Arturo A; Pino, Verónica; Fresno, María R; Jiménez-Abizanda, Ana I; Álvarez, Sergio; Ayala, Juan H; Afonso, Ana M

    2017-04-01

    Free fatty acids and sensory profiles were obtained for cheeses made with raw goat milk and vegetable coagulant, derived from the cardoon flower ( Cynara cardunculus), at different ripening times (7 and 20 days). A solid-liquid phase extraction method followed by solid-phase extraction and gas chromatography was used. Profiles were also obtained with cheeses made with commercial coagulant, traditional kid rennet paste, and mixture coagulant (vegetable coagulant-kid rennet). The use of vegetable coagulant and vegetable coagulant-kid rennet is common in traditional Protected Designation of Origin cheeses such as " Queso Flor de Guía" and " Queso Media Flor de Guía" (Spain). Contents of short-chain free fatty acids (7.5-22.5 mmol·kg -1 ), medium-chain free fatty acids (0.4-3.7 mmol·kg -1 ), and long-chain free fatty acids (0.2-2.1 mmol·kg -1 ) varied depending on the coagulant type and the ripening time. Vegetable coagulant cheeses present odour intensity and flavour intensity much higher than commercial coagulant cheeses in the sensory analysis for cheeses obtained with seven days of ripening, but the values decrease when increasing the ripening time. Multivariate analysis allowed us to differentiate cheese samples according to the ripening time when using lipolytic profile and according to the coagulant type using the sensory profile.

  8. Overview of platelet physiology and laboratory evaluation of platelet function.

    PubMed

    Rodgers, G M

    1999-06-01

    Appropriate laboratory testing for the platelet-type bleeding disorders hinges on an adequate assessment in the history and physical examination. Patients with histories and screening laboratory results consistent with coagulation disorders (hemophilia, disseminated intravascular coagulation) are not appropriate candidates for platelet function testing. In contrast, patients with a lifelong history of platelet-type bleeding symptoms and perhaps a positive family history of bleeding would be appropriate for testing. Figure 6 depicts one strategy to evaluate these patients. Platelet morphology can easily be evaluated to screen for two uncommon qualitative platelet disorders: Bernard-Soulier syndrome (associated with giant platelets) and gray platelet syndrome, a subtype of storage pool disorder in which platelet granulation is morphologically abnormal by light microscopy. If the bleeding disorder occurred later in life (no bleeding with surgery or trauma early in life), the focus should be on acquired disorders of platelet function. For those patients thought to have an inherited disorder, testing for vWD should be done initially because approximately 1% of the population has vWD. The complete vWD panel (factor VIII coagulant activity, vWf antigen, ristocetin cofactor activity) should be performed because many patients will have abnormalities of only one particular panel component. Patients diagnosed with vWD should be classified using multimeric analysis to identify the type 1 vWD patients likely to respond to DDAVP. If vWD studies are normal, platelet aggregation testing should be performed, ensuring that no antiplatelet medications have been ingested at least 1 week before testing. If platelet aggregation tests are normal and if suspicion for an inherited disorder remains high, vWD testing should be repeated. The evaluation of thrombocytopenia may require bone marrow examination to exclude primary hematologic disorders. If future studies with thrombopoietin assays confirm preliminary results, however, the bone marrow examination of certain patients may be replaced by a thrombopoietin level.

  9. Whole blood coagulation and platelet activation in the athlete: a comparison of marathon, triathlon and long distance cycling.

    PubMed

    Hanke, Alexander A; Staib, A; Görlinger, K; Perrey, M; Dirkmann, D; Kienbaum, P

    2010-02-26

    Serious thrombembolic events occur in otherwise healthy marathon athletes during competition. We tested the hypothesis that during heavy endurance sports coagulation and platelets are activated depending on the type of endurance sport with respect to its running fraction. 68 healthy athletes participating in marathon (MAR, running 42 km, n = 24), triathlon (TRI, swimming 2.5 km + cycling 90 km + running 21 km, n = 22), and long distance cycling (CYC, 151 km, n = 22) were included in the study. Blood samples were taken before and immediately after completion of competition to perform rotational thrombelastometry. We assessed coagulation time (CT), maximum clot firmness (MCF) after intrinsically activation and fibrin polymerization (FIBTEM). Furthermore, platelet aggregation was tested after activation with ADP and thrombin activating peptide 6 (TRAP) by using multiple platelet function analyzer. Complete data sets were obtained in 58 athletes (MAR: n = 20, TRI: n = 19, CYC: n = 19). CT significantly decreased in all groups (MAR -9.9%, TRI -8.3%, CYC -7.4%) without differences between groups. In parallel, MCF (MAR +7.4%, TRI +6.1%, CYC +8.3%) and fibrin polymerization (MAR +14.7%, TRI +6.1%, CYC +8.3%) were significantly increased in all groups. However, platelets were only activated during MAR and TRI as indicated by increased AUC during TRAP-activation (MAR +15.8%) and increased AUC during ADP-activation in MAR (+50.3%) and TRI (+57.5%). While coagulation is activated during physical activity irrespective of type we observed significant platelet activation only during marathon and to a lesser extent during triathlon. We speculate that prolonged running may increase platelet activity, possibly, due to mechanical alteration. Thus, particularly prolonged running may increase the risk of thrombembolic incidents in running athletes.

  10. Moderate-intensity exercise improves the thromboelastography coagulation index in children with severe hemophilia A.

    PubMed

    Li, Kui-Xing; Xiao, Juan; Zhao, Yong-Qiang; Shou, Wei-Ling; Chen, Meng; Li, Zhuo; Poon, Man-Chiu; Han, Hui-Jun

    2016-10-01

    This pilot study explored the effect of moderate-intensity exercise on factor VIII (FVIII) activity and global hemostatic status of the children with severe hemophilia A. Eleven children aged 6 to 15 years with severe hemophilia A participated in a moderate-intensity exercise test by using Recumbent Cross Trainer (NuStep, T5XR) for at least 10 min after reaching the target heart rate or until volitional exhaustion within a safety framework. Blood samples were collected pre and postexercise for plasma FVIII: C and thromboelastography (TEG) parameters and coagulation index. The average duration of exercise was 11.8 min (10-13 min). There was no report on bleeding events or adverse symptoms requiring termination of the exercise test. The average FVIII activity of the 11 children was 0.66 (0.5-0.8) IU/dl before and 0.93 (0.5-2.3) IU/dl after exercise. The increase of FVIII in the 11 children as a group was not statistically significant (P = 0.052). There were significant changes of TEG measurements, with shortening of R (P < 0.05), and increase in K decrease (P < 0.05), alpha angle (P < 0.05), maximum amplitude (P < 0.05), and coagulation index (P < 0.01). Among the 11 children, the relative coagulation index increase after exercise was greater than 50% in seven (63.6%), less than 20% in three (27.3%), and less than 10% in one (9.1%). TEG analysis showed that the global hemostatic function for the children with severe hemophilia A can be enhanced after moderate-intensity exercise.

  11. Whole blood coagulation and platelet activation in the athlete: A comparison of marathon, triathlon and long distance cycling

    PubMed Central

    2010-01-01

    Introduction Serious thrombembolic events occur in otherwise healthy marathon athletes during competition. We tested the hypothesis that during heavy endurance sports coagulation and platelets are activated depending on the type of endurance sport with respect to its running fraction. Materials and Methods 68 healthy athletes participating in marathon (MAR, running 42 km, n = 24), triathlon (TRI, swimming 2.5 km + cycling 90 km + running 21 km, n = 22), and long distance cycling (CYC, 151 km, n = 22) were included in the study. Blood samples were taken before and immediately after completion of competition to perform rotational thrombelastometry. We assessed coagulation time (CT), maximum clot firmness (MCF) after intrinsically activation and fibrin polymerization (FIBTEM). Furthermore, platelet aggregation was tested after activation with ADP and thrombin activating peptide 6 (TRAP) by using multiple platelet function analyzer. Results Complete data sets were obtained in 58 athletes (MAR: n = 20, TRI: n = 19, CYC: n = 19). CT significantly decreased in all groups (MAR -9.9%, TRI -8.3%, CYC -7.4%) without differences between groups. In parallel, MCF (MAR +7.4%, TRI +6.1%, CYC +8.3%) and fibrin polymerization (MAR +14.7%, TRI +6.1%, CYC +8.3%) were significantly increased in all groups. However, platelets were only activated during MAR and TRI as indicated by increased AUC during TRAP-activation (MAR +15.8%) and increased AUC during ADP-activation in MAR (+50.3%) and TRI (+57.5%). Discussion While coagulation is activated during physical activity irrespective of type we observed significant platelet activation only during marathon and to a lesser extent during triathlon. We speculate that prolonged running may increase platelet activity, possibly, due to mechanical alteration. Thus, particularly prolonged running may increase the risk of thrombembolic incidents in running athletes. PMID:20452885

  12. Comparison between thromboelastography and conventional coagulation test: Should we abandon conventional coagulation tests in polytrauma patients?

    PubMed

    Tur Martínez, Jaume; Petrone, Patrizio; Axelrad, Alexander; Marini, Corrado P

    2018-05-12

    TEG provides an in-vivo assessment of viscoelastic clot strength in whole blood compared with CCT, which may not reflect the influence of platelets. The aim of this study was to compare TEG vs. CCT in trauma patients stratified by mechanism of injury (MOI) and pre-existing coagulation status. A retrospective, observational study of 230 polytrauma patients admitted to a University Hospital Level 1 Trauma Center, with TEG and CCT on admission stratified by MOI: multiple trauma (MT), isolated traumatic brain injury (TBI) or MT+TBI. Statistical analysis included correlation between TEG and CCT in all groups and a subgroup analysis of anticoagulated patients. Data were analyzed with ANOVA, Spearman and lineal regression when appropriate. Statistical significance was accepted at P<0.05. TEG was normal in 28.7%, hypercoagulable in 68.3%, hypocoagulable in 7%. There was no difference in TEG status among the groups. The coagulation status was not affected by age, ISS or shock. The CCT were abnormal in 63.6% of patients with normal TEG. Normal or hypercoagulable-TEG was found in 21/23 patients on Coumadin who had elevated INR and in 10/11 patients on NOAC. An analysis of the 23 patients on Coumadin stratified by INR showed a normal or hypercoagulable-TEG in 21/23 patients. Only 2 patients had a hypocoagulable-TEG. Mortality was 5.2% (58.3% severe TBI). TEG is more useful than CCT in polytrauma patients, including patients on anticoagulants. TBI could increase the incidence of hypercoagulability in trauma. CCT are not useful from the standpoint of treatment. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Global measurement of coagulation in plasma from normal and haemophilia dogs using a novel modified thrombin generation test – Demonstrated in vitro and ex vivo

    PubMed Central

    Madsen, Daniel Elenius; Nichols, Timothy C.; Merricks, Elizabeth P.; Waters, Emily K.; Wiinberg, Bo

    2017-01-01

    Introduction Canine models of severe haemophilia resemble their human equivalents both regarding clinical bleeding phenotype and response to treatment. Therefore pre-clinical studies in haemophilia dogs have allowed researchers to make valuable translational predictions regarding the potency and efficacy of new anti-haemophilia drugs (AHDs) in humans. To refine in vivo experiments and reduce number of animals, such translational studies are ideally preceded by in vitro prediction of compound efficacy using a plasma based global coagulation method. One such widely used method is the thrombin generation test (TGT). Unfortunately, commercially available TGTs are incapable of distinguishing between normal and haemophilia canine plasma, and therefore in vitro prediction using TGT has so far not been possible in canine plasma material. Aim Establish a modified TGT capable of: 1) distinguishing between normal and haemophilia canine plasma, 2) monitoring correlation between canine plasma levels of coagulation factor VIII (FVIII) and IX (FIX) and thrombin generation, 3) assessing for agreement between compound activity and thrombin generation in ex vivo samples. Methods A modified TGT assay was established where coagulation was triggered using a commercially available activated partial thromboplastin time reagent. Results With the modified TGT a significant difference was observed in thrombin generation between normal and haemophilia canine plasma. A dose dependent thrombin generation was observed when assessing haemophilia A and B plasma spiked with dilution series of FVIII and FIX, respectively. Correlation between FVIII activity and thrombin generation was observed when analyzing samples from haemophilia A dogs dosed with canine FVIII. Limit of detection was 0.1% (v/v) FVIII or FIX. Conclusion A novel modified TGT suitable for monitoring and prediction of replacement therapy efficacy in plasma from haemophilia A and B dogs was established. PMID:28384182

  14. Jar Test. Training Module 5.230.2.77.

    ERIC Educational Resources Information Center

    Bonte, John L.; Davidson, Arnold C.

    This document is an instructional module package prepared in objective form for use by an instructor familiar with the jar test and its application to the coagulation, floculation and sedimentation processes, and the chemical precipitation process. Included are objectives, an instructor guide, student handouts, and transparency masters. A video…

  15. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge

    NASA Astrophysics Data System (ADS)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Saǧlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioǧlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements.

  16. Application of steel slag coated with sodium hydroxide to enhance precipitation-coagulation for phosphorus removal.

    PubMed

    Park, Taejun; Ampunan, Vanvimol; Maeng, Sungkyu; Chung, Eunhyea

    2017-01-01

    Phosphorus removal has been studied for decades to reduce the environmental impact of phosphorus in natural waterbodies. Slag has been applied for the phosphorus removal by several mechanisms. In this study, sodium hydroxide coating was applied on the slag surface to enhance the efficiency of precipitation-coagulation process. In the batch test, it was found that the capacity of the slag to maintain high pH decreases with increasing its exposure time to the aqueous solution. In the column test, the coarse-grained coated slag showed higher phosphorus removal efficiency than the fine-grained uncoated slag. The coated slag maintained pH higher than uncoated slag and, accordingly, the removal efficiency of phosphorus was higher. Especially, when pH was less than 8, the removal efficiency decreased significantly. However, coated slag provided an excess amount of aluminum and sodium. Thus, a return process to reuse aluminum and sodium as a coagulant was introduced. The return process yields longer lifespan of slag with higher phosphorus removal and lower concentration of cations in the effluent. With the return process, the phosphorus removal efficiency was kept higher than 60% until 150 bed volumes; meanwhile, the efficiency without return process became lower than 60% at 25 bed volumes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. The influence of hydraulic conditions on coagulation process effectiveness

    NASA Astrophysics Data System (ADS)

    Sambor, Aleksandra; Ferenc, Zbigniew

    2017-11-01

    This paper presents the impact that small changes in the hydraulic installation between the flocculation chamber and the sedimentation tanks have on coagulation process effectiveness. This study has shown significant improvements in the parameters of the treated water. The research was conducted in two treatment systems: reference and test, in order to compare the changes that were introduced in the time period between January and May 2016. The hydraulic conditions between the flocculation chamber and the sedimentation tank were changed in the test system, leaving the reference system unchanged for comparative purposes. The height-wise positioning of the sedimentation tank relative to the flocculation chamber resulted in a formation of a cascade at the flocculation chamber drain at a height of 0.60m. Air was therefore introduced into the water, forming an air-water mixture, which disturbed the flow between the devices. It was found that floc transported by the pipeline was broken down, which hampered sedimentation in the sedimentation tank. This was confirmed by the analysis of chosen parameters from treated water. After changes in the hydraulic system, changes in water turbidity were noticed, indicating an increase in post-coagulation suspension separation effectiveness. Consequently, an increase in organic carbon removal was found relative to the reference system. This change influenced changes in UV254 absorbance to a much lesser extent.

  18. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    PubMed

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  19. Whole blood coagulation analyzers.

    PubMed

    1997-08-01

    Whole blood Coagulation analyzers (WBCAs) are widely used point-of-care (POC) testing devices found primarily in cardiothoracic surgical suites and cardia catheterization laboratories. Most of these devices can perform a number of coagulation tests that provide information about a patient's blood clotting status. Clinicians use the results of the WBCA tests, which are available minutes after applying a blood sample, primarily to monitor the effectiveness of heparin therapy--an anticoagulation therapy used during cardiopulmonary bypass (CPB) surgery, angioplasty, hemodialysis, and other clinical procedures. In this study we evaluated five WBCAs from four suppliers. Our testing focused on the applications for which WBCAs are primarily used: Monitoring moderate to high heparin levels, as would be required, for example, during CPB are angioplasty. For this function, WCBAs are typically used to perform an activated clotting time (ACT) test or, as one supplier refers to its test, a heparin management test (HMT). All models included in this study offered an ACT test or an HMT. Monitoring low heparin levels, as would be required, for example,during hemodialysis. For this function, WBCAs would normally be used to perform either a low-range ACT (LACT) test or a whole blood activated partial thromboplastin time (WBAPTT) test. Most of the evaluated units could perform at least one of these tests; one unit did not offer either test and was therefore not rated for this application. We rated and ranked each evaluated model separately for each of these two applications. In addition, we provided a combined rating and ranking that considers the units' appropriateness for performing both application. We based our conclusions on a unit's performance and humans factor design, as determined by our testing, and on its five-year life-cycle cost, as determined by our net present value (NPV) analysis. While we rated all evaluated units acceptable for each appropriate category, we did identify some significant differences that enabled us to rank the units in order of preference. We have included a Selection, Purchasing, and use guide at the end of this study to help facilities identify the unit that will best meet their needs.

  20. Development of a standardized laparoscopic caecum resection model to simulate laparoscopic appendectomy in rats

    PubMed Central

    2014-01-01

    Background Laparoscopic appendectomy (LA) has become one of the most common surgical procedures to date. To improve and standardize this technique further, cost-effective and reliable animal models are needed. Methods In a pilot study, 30 Wistar rats underwent laparoscopic caecum resection (as rats do not have an appendix vermiformis), to optimize the instrumental and surgical parameters. A subsequent test study was performed in another 30 rats to compare three different techniques for caecum resection and bowel closure. Results Bipolar coagulation led to an insufficiency of caecal stump closure in all operated rats (Group 1, n = 10). Endoloop ligation followed by bipolar coagulation and resection (Group 2, n = 10) or resection with a LigaSure™ device (Group 3, n = 10) resulted in sufficient caecal stump closure. Conclusions We developed a LA model enabling us to compare three different caecum resection techniques in rats. In conclusion, only endoloop closure followed by bipolar coagulation proved to be a secure and cost-effective surgical approach. PMID:24934381

  1. Potential of tin (IV) chloride for treatment in Alor Pongsu as stabilized landfill leachate

    NASA Astrophysics Data System (ADS)

    Zainal, Sharifah Farah Fariza Syed; Aziz, Hamidi Abdul

    2017-10-01

    Leachate production from landfilling contributes crucial pollutants to the environment. This study examined the potential of tin (IV) chloride as coagulant that involved charge neutralization and sweep flocculation mechanisms. The negative charge of leachate is neutralized by adding tin (IV) chloride as cationic coagulant which resulted precipitation and swept most of the colloids and dissolved solids that entrapped in the settling as hydrous oxide floc. Parameters such as suspended solid (SS) content, color, and chemical oxygen demand (COD) were analyzed using standard jar test procedures. The best condition was observed at pH 8, with removal efficiencies of 75.99 %, 99.29 % and 98.36 % for COD, SS, and color, respectively. At optimum dosage, tin (IV) chloride successfully removed 98.40 % for color, 99.54 % for SS and 71.53 % for COD. These results indicated the satisfactory performance of tin (IV) chloride. Hence, tin (IV) chloride is a potential coagulant for the treatment of Alor Pongsu Landfill leachate.

  2. Temperature effects on flocculation, using different coagulants.

    PubMed

    Fitzpatrick, C S B; Fradin, E; Gregory, J

    2004-01-01

    Temperature is known to affect flocculation and filter performance. Jar tests have been conducted in the laboratory, using a photometric dispersion analyser (PDA) to assess the effects of temperature on floc formation, breakage and reformation. Alum, ferric sulphate and three polyaluminium chloride (PACI) coagulants have been investigated for temperatures ranging between 6 and 29 degrees C for a suspension of kaolin clay in London tap water. Results confirm that floc formation is slower at lower temperatures for all coagulants. A commercial PACl product, PAX XL 19, produces the largest flocs for all temperatures; and alum the smallest. Increasing the shear rate results in floc breakage in all cases and the flocs never reform to their original size. This effect is most notable for temperatures around 15 degrees C. Breakage, in terms of floc size reduction, is greater for higher temperatures, suggesting a weaker floc. Recovery after increased shear is greater at lower temperatures implying that floc break-up is more reversible for lower temperatures.

  3. Competition of coagulation sink and source rate: New particle formation in the Pearl River Delta of China

    NASA Astrophysics Data System (ADS)

    Gong, Youguo; Hu, Min; Cheng, Yafang; Su, Hang; Yue, Dingli; Liu, Feng; Wiedensohler, A.; Wang, Zhibin; Kalesse, H.; Liu, Shang; Wu, Zhijun; Xiao, Kaitao; Mi, Puchun; Zhang, Yuanhang

    The coagulation sink and its role in new particle formation are investigated based on data obtained during the PRIDE-PRD2004 campaign at Xinken of Pearl River Delta, China. Analysis of size distributions and mode contributions of the coagulation sink show that the observed higher load of accumulation mode particles impose a significant effect on the coagulation sink and result in higher coagulation sinks at Xinken despite of the lower total particle number compared with other areas. Hence it is concluded that the higher coagulation sink may depress the occurrence frequency of new particle formation events. The strategies targeting at controlling accumulation mode particles may have influences on the frequency of new particle formation events at this area. The factors affecting the coagulation sink are evaluated. The relatively lower ambient relative humidities may weaken the coagulation sink and facilitate the occurrence of new particle formation events during noontime, while the surmise of nucleation and growth involving organic matter may imply an actually higher coagulation sink than expected. These factors have a significant influence on the ultimate fate of the newly formed nuclei and new particle formation. A comparison of event and non-event days indicates that the coagulation sink is not the only decisive factor affecting new particle formation, other factors including the precursor vapors and photochemical activity are none the less important either. Competition of coagulation sink and high source rate leads to the occurrence of new particle formation events at Xinken.

  4. Imaging of blood plasma coagulation at supported lipid membranes.

    PubMed

    Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia

    2011-12-15

    The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  5. [Effect on the microbicidal efficacy of formaldehyde, glutardialdehyde, peracetic acid, chloramine T (N-chloro-4-toluenesulfonamide), m-cresol, ethanol and benzyldimethyldodecacylammonium bromide by blood (model experiments for chemical disinfection of instruments)].

    PubMed

    Spicher, G; Peters, J

    1998-02-01

    In a preceding paper (Zbl. Hyg. 191 [1991] 457-477) we reported on the dependence of the microbicidal efficacy of active agents of the disinfection of instruments on the amount of coagulated blood adhering to the instruments. In the present investigation, we were interested in the dependence of the microbicidal effects on the amount of blood in the solutions of the active agents. Test areas of 2 cm2 were contaminated with 50 and 100 microliters coagulating blood, respectively, containing cells of Staphylococcus aureus as test germ. The solutions of the microbicidal agents were contaminated with heparinized blood up to a concentration of 4% immediately before starting the disinfection and 24 hours before, respectively. After a period of action lasting 1 hour at 20 degrees C, the relative number of test germs capable of multiplying (N/N0) was determined. The concentration of the microbicidal substances reducing the relative number of test germs capable to multiply to 10(-4) served for estimating the dependence of the microbicidal efficacy of the agents on the blood content of the solutions. The experimental results depended on the thickness of the layer of coagulated blood. The dependence of the efficacy of the microbicidal substances on the blood content of the solutions was the higher the thinner the blood layer was. At a thickness of the layer of the coagulated blood of 0.25 mm, a blood content of the solution of 4%, and applying it immediately after adding the blood, the concentration of glutardialdehyde had to be 1.6 times that without blood to reach the same microbicidal efficacy. When applying the solution 24 hours after adding the blood, the concentration of glutardialdehyde had to be 4.2 times that without blood. The quaternary ammonium compound reacted faster with the blood than did glutardialdehyde; the respective factors were 2.6 and 4.5. The concentration factors of chloramine T were 3.3 and 3.8. Under the conditions of the test, peracetic acid exhibited small concentration factors: 1.3 and 1.6. The microbicidal efficacy of ethanol, formaldehyde and m-cresol soap solution was not or only slightly altered by the amount of blood in the solution of the microbicidal agent.

  6. Coagulation of Dust Particles in Argon Plasma of RF Discharge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankelevich, Yu. A.; Olevanov, M. A.; Pal, A. F.

    2008-09-07

    The experiments on coagulation of poly-disperse particles with various size distributions injected into the argon plasma of the magnetron radio-frequency discharge are discussed. The experiments were carried out under the conditions similar to those using dusty plasma for technology applications. Within the created theory the threshold behavior of the coagulation process was explained for the first time, the estimation of the critical particle size for onset of a fast coagulation was made, and the analytical calculation of the coagulation rate of dust particles was performed. The proposed coagulation mechanism makes it possible to describe the typical features of coagulation processesmore » observed in experiments and to explain the effects of attraction and coalescence of highly negatively charged microns size particles.« less

  7. Coagulant recovery and reuse for drinking water treatment.

    PubMed

    Keeley, James; Jarvis, Peter; Smith, Andrea D; Judd, Simon J

    2016-01-01

    Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgin coagulant treatment performance. This study examines the individual and successive separation performance of several novel and existing ferric coagulant recovery purification technologies to attain virgin coagulant purity levels. The new suggested approach of alkali extraction of dissolved organic compounds (DOC) from waterworks sludge prior to acidic solubilisation of ferric coagulants provided the same 14:1 selectivity ratio (874 mg/L Fe vs. 61 mg/L DOC) to the more established size separation using ultrafiltration (1285 mg/L Fe vs. 91 mg/L DOC). Cation exchange Donnan membranes were also examined: while highly selective (2555 mg/L Fe vs. 29 mg/L DOC, 88:1 selectivity), the low pH of the recovered ferric solution impaired subsequent treatment performance. The application of powdered activated carbon (PAC) to ultrafiltration or alkali pre-treated sludge, dosed at 80 mg/mg DOC, reduced recovered ferric DOC contamination to <1 mg/L but in practice, this option would incur significant costs. The treatment performance of the purified recovered coagulants was compared to that of virgin reagent with reference to key water quality parameters. Several PAC-polished recovered coagulants provided the same or improved DOC and turbidity removal as virgin coagulant, as well as demonstrating the potential to reduce disinfection byproducts and regulated metals to levels comparable to that attained from virgin material. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Pre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories.

    PubMed

    Magnette, A; Chatelain, M; Chatelain, B; Ten Cate, H; Mullier, F

    2016-01-01

    Ensuring quality has become a daily requirement in laboratories. In haemostasis, even more than in other disciplines of biology, quality is determined by a pre-analytical step that encompasses all procedures, starting with the formulation of the medical question, and includes patient preparation, sample collection, handling, transportation, processing, and storage until time of analysis. This step, based on a variety of manual activities, is the most vulnerable part of the total testing process and is a major component of the reliability and validity of results in haemostasis and constitutes the most important source of erroneous or un-interpretable results. Pre-analytical errors may occur throughout the testing process and arise from unsuitable, inappropriate or wrongly handled procedures. Problems may arise during the collection of blood specimens such as misidentification of the sample, use of inadequate devices or needles, incorrect order of draw, prolonged tourniquet placing, unsuccessful attempts to locate the vein, incorrect use of additive tubes, collection of unsuitable samples for quality or quantity, inappropriate mixing of a sample, etc. Some factors can alter the result of a sample constituent after collection during transportation, preparation and storage. Laboratory errors can often have serious adverse consequences. Lack of standardized procedures for sample collection accounts for most of the errors encountered within the total testing process. They can also have clinical consequences as well as a significant impact on patient care, especially those related to specialized tests as these are often considered as "diagnostic". Controlling pre-analytical variables is critical since this has a direct influence on the quality of results and on their clinical reliability. The accurate standardization of the pre-analytical phase is of pivotal importance for achieving reliable results of coagulation tests and should reduce the side effects of the influence factors. This review is a summary of the most important recommendations regarding the importance of pre-analytical factors for coagulation testing and should be a tool to increase awareness about the importance of pre-analytical factors for coagulation testing.

  9. Coagulation dynamics of a blood sample by multiple scattering analysis

    NASA Astrophysics Data System (ADS)

    Faivre, Magalie; Peltié, Philippe; Planat-Chrétien, Anne; Cosnier, Marie-Line; Cubizolles, Myriam; Nougier, Christophe; Négrier, Claude; Pouteau, Patrick

    2011-05-01

    We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.

  10. Treatment of waste water by coagulation and flocculation using biomaterials

    NASA Astrophysics Data System (ADS)

    Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh

    2017-11-01

    The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.

  11. The evolution of biomass-burning aerosol size distributions due to coagulation: dependence on fire and meteorological details and parameterization

    NASA Astrophysics Data System (ADS)

    Sakamoto, Kimiko M.; Laing, James R.; Stevens, Robin G.; Jaffe, Daniel A.; Pierce, Jeffrey R.

    2016-06-01

    Biomass-burning aerosols have a significant effect on global and regional aerosol climate forcings. To model the magnitude of these effects accurately requires knowledge of the size distribution of the emitted and evolving aerosol particles. Current biomass-burning inventories do not include size distributions, and global and regional models generally assume a fixed size distribution from all biomass-burning emissions. However, biomass-burning size distributions evolve in the plume due to coagulation and net organic aerosol (OA) evaporation or formation, and the plume processes occur on spacial scales smaller than global/regional-model grid boxes. The extent of this size-distribution evolution is dependent on a variety of factors relating to the emission source and atmospheric conditions. Therefore, accurately accounting for biomass-burning aerosol size in global models requires an effective aerosol size distribution that accounts for this sub-grid evolution and can be derived from available emission-inventory and meteorological parameters. In this paper, we perform a detailed investigation of the effects of coagulation on the aerosol size distribution in biomass-burning plumes. We compare the effect of coagulation to that of OA evaporation and formation. We develop coagulation-only parameterizations for effective biomass-burning size distributions using the SAM-TOMAS large-eddy simulation plume model. For the most-sophisticated parameterization, we use the Gaussian Emulation Machine for Sensitivity Analysis (GEM-SA) to build a parameterization of the aged size distribution based on the SAM-TOMAS output and seven inputs: emission median dry diameter, emission distribution modal width, mass emissions flux, fire area, mean boundary-layer wind speed, plume mixing depth, and time/distance since emission. This parameterization was tested against an independent set of SAM-TOMAS simulations and yields R2 values of 0.83 and 0.89 for Dpm and modal width, respectively. The size distribution is particularly sensitive to the mass emissions flux, fire area, wind speed, and time, and we provide simplified fits of the aged size distribution to just these input variables. The simplified fits were tested against 11 aged biomass-burning size distributions observed at the Mt. Bachelor Observatory in August 2015. The simple fits captured over half of the variability in observed Dpm and modal width even though the freshly emitted Dpm and modal widths were unknown. These fits may be used in global and regional aerosol models. Finally, we show that coagulation generally leads to greater changes in the particle size distribution than OA evaporation/formation does, using estimates of OA production/loss from the literature.

  12. Polyferric sulphate: preparation, characterisation and application in coagulation experiments.

    PubMed

    Zouboulis, A I; Moussas, P A; Vasilakou, F

    2008-07-15

    The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.

  13. Influence of starch on microalgal biomass recovery, settleability and biogas production.

    PubMed

    Gutiérrez, Raquel; Ferrer, Ivet; García, Joan; Uggetti, Enrica

    2015-06-01

    In the context of wastewater treatment with microalgae cultures, coagulation-flocculation followed by sedimentation is one of the suitable options for microalgae harvesting. This process is enabled by the addition of chemicals (e.g. iron). However, in a biorefinery perspective, it is important to avoid possible contamination of downstream products caused by chemicals addition. The aim of this study was to evaluate the effect of potato starch as flocculant for microalgal biomass coagulation-flocculation and sedimentation. The optimal flocculant dose (25mg/L) was determined with jar tests. Such a concentration led to more than 95% biomass recovery (turbidity<9NTU). The settleability of flocs was studied using an elutriation apparatus measuring the settling velocities distribution. This test underlined the positive effect of starch on the biomass settling velocity, increasing to >70% the percentage of particles with settling velocities >6.5m/h. Finally, biochemical methane potential tests showed that starch biodegradation increased the biogas production from harvested biomass. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Comparison of in vitro tests for evaluation of passive transfer of immunoglobulins in giraffe (Giraffa camelopardalis).

    PubMed

    Miller, M; Coville, B; Abou-Madi, N; Olsen, J

    1999-03-01

    Serum samples from captive giraffe (Giraffa camelopardalis) were tested to assess passive transfer of immunoglobulins using in vitro methods developed for domestic ruminants. Estimated immunoglobulin levels were compared using five tests (protein electrophoresis, total protein refractometry, zinc sulfate turbidity, glutaraldehyde coagulation, and sodium sulfite turbidity). A linear relationship was observed among total protein, gamma globulin (electrophoretic measurement), and immunoglobulin level based on spectrophotometric measurement of zinc sulfate turbidity. Nonquantitative assays also demonstrated statistical correlation with the quantitative methods. Using criteria similar to those established for domestic species, cutoff values for failure of passive transfer (FPT) were established for these tests in neonatal giraffe: 1) total protein <6.0 g/dl; 2) gamma globulin < 0.5 g/dl; 3) estimated immunoglobulin level < 1,000 mg/dl (zinc sulfate turbidity); 4) glutaraldehyde coagulation test negative; or 5) no visually detectable turbidity in 16% sodium sulfite or Bova-S negative. Retrospective examination of the medical histories showed a strong statistical association between animals designated as having FPT and those that were removed from their dams based on clinical assessment to be hand-reared. Application of these tests in the field should allow earlier detection and intervention for FPT in neonatal giraffe.

  15. Nanoparticle coagulation in fractionally charged and charge fluctuating dusty plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nunomura, Shota; Kondo, Michio; Shiratani, Masaharu

    2008-08-15

    The kinetics of nanoparticle coagulation has been studied in fractionally charged and charge fluctuating dusty plasmas. The coagulation occurs when the mutual collision frequency among nanoparticles exceeds their charging and decharging/neutralization frequency. Interestingly, the coagulation is suppressed while a fraction (several percent) of nanoparticles are negatively charged in a plasma, in which stochastic charging plays an important role. A model is developed to predict a phase diagram of the coagulation and its suppression.

  16. Comparison of inclined plate sedimentation and dissolved air flotation for the minimisation of subsequent nitrogenous disinfection by-product formation.

    PubMed

    Chu, Wen-Hai; Gao, Nai-Yun; Templeton, Michael R; Yin, Da-Qiang

    2011-04-01

    The formation of disinfection by-products (DBPs), including both nitrogenous disinfection by-products (N-DBPs) and carbonaceous disinfection by-products (C-DBPs), was investigated upon chlorination of water samples following two treatment processes: (i) coagulation-inclined plate sedimentation (IPS)-filtration and (ii) coagulation-dissolved air flotation (DAF)-filtration. The removal of algae, dissolved organic nitrogen (DON), dissolved organic carbon (DOC) and UV(254) by coagulation-DAF-filtration was superior to coagulation-IPS-filtration. On average, 53%, 53% and 31% of DOC, DON and UV(254) were removed by coagulation-DAF-filtration process, which were higher than 47%, 31% and 27% of that by coagulation-IPS-filtration process. Additionally, coagulation-IPS-filtration performed less well at removing the low molecular weight organics than coagulation-DAF-filtration process. The concentrations of chloroform, dichloroacetamide (DCAcAm) and dichloroacetonitrile (DCAN) formed during chlorination after coagulation-DAF-filtration reached their maximum values of 13, 1.5 and 4.7μgL(-1), respectively, and were lower than those after coagulation-IPS-filtration with the maximum detected levels of 17, 2.9 and 6.3μgL(-1). However, the trichloronitromethane (TCNM) concentration after the two processes was similar, suggesting that DON may have less of a contribution to TCNM formation than DCAcAm and DCAN. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods.

    PubMed

    Oberfrank, Stephanie; Drechsel, Hartmut; Sinn, Stefan; Northoff, Hinnak; Gehring, Frank K

    2016-02-24

    The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor's own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field.

  18. Predictive models for water sources with high susceptibility for bromine-containing disinfection by-product formation: implications for water treatment.

    PubMed

    Watson, Kalinda; Farré, Maria José; Birt, James; McGree, James; Knight, Nicole

    2015-02-01

    This study examines a matrix of synthetic water samples designed to include conditions that favour brominated disinfection by-product (Br-DBP) formation, in order to provide predictive models suitable for high Br-DBP forming waters such as salinity-impacted waters. Br-DBPs are known to be more toxic than their chlorinated analogues, in general, and their formation may be favoured by routine water treatment practices such as coagulation/flocculation under specific conditions; therefore, circumstances surrounding their formation must be understood. The chosen factors were bromide concentration, mineral alkalinity, bromide to dissolved organic carbon (Br/DOC) ratio and Suwannee River natural organic matter concentration. The relationships between these parameters and DBP formation were evaluated by response surface modelling of data generated using a face-centred central composite experimental design. Predictive models for ten brominated and/or chlorinated DBPs are presented, as well as models for total trihalomethanes (tTHMs) and total dihaloacetonitriles (tDHANs), and bromide substitution factors for the THMs and DHANs classes. The relationships described revealed that increasing alkalinity and increasing Br/DOC ratio were associated with increasing bromination of THMs and DHANs, suggesting that DOC lowering treatment methods that do not also remove bromide such as enhanced coagulation may create optimal conditions for Br-DBP formation in waters in which bromide is present.

  19. Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods

    PubMed Central

    Oberfrank, Stephanie; Drechsel, Hartmut; Sinn, Stefan; Northoff, Hinnak; Gehring, Frank K.

    2016-01-01

    The determination of fibrinogen levels is one of the most important coagulation measurements in medicine. It plays a crucial part in diagnostic and therapeutic decisions, often associated with time-critical conditions. The commonly used measurement is the Clauss fibrinogen assay (CFA) where plasma is activated by thrombin reagent and which is conducted by mechanical/turbidimetric devices. As quartz crystal microbalance sensors with dissipation (QCM-D) based devices have a small footprint, can be operated easily and allow measurements independently from sample transportation time, laboratory location, availability and opening hours, they offer a great opportunity to complement laboratory CFA measurements. Therefore, the objective of the work was to (1) transfer the CFA to the QCM-D method; (2) develop an easy, time- and cost-effective procedure and (3) compare the results with references. Different sensor coatings (donor’s own plasma; gold surface) and different QCM-D parameters (frequency signal shift; its calculated turning point; dissipation signal shift) were sampled. The results demonstrate the suitability for a QCM-D-based CFA in physiological fibrinogen ranges. Results were obtained in less than 1 min and in very good agreement with a standardized reference (Merlin coagulometer). The results provide a good basis for further investigation and pave the way to a possible application of QCM-D in clinical and non-clinical routine in the medical field. PMID:26927107

  20. 21 CFR 878.4400 - Electrosurgical cutting and coagulation device and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrosurgical cutting and coagulation device and....4400 Electrosurgical cutting and coagulation device and accessories. (a) Identification. An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control...

  1. Degradation of black liquor from bioethanol process using coagulation and Fenton-like methods

    NASA Astrophysics Data System (ADS)

    Muryanto, Muryanto; Sari, Ajeng Arum; Abimanyu, Haznan

    2017-01-01

    Black liquor is one of the main by-products of the pretreatment process in bioethanol production from oil palm empty fruit bunches. Black liquor wastewater releases black coloured effluent with high chemical oxygen demand (COD) and low dissolved oxygen (DO). It had a distinctive dark coloration, high alkalinity (pH=13), high organic content (COD > 50,000 ppm) and a high solid content (TSS > 5,000 ppm). Lignin destruction can be done by using high oxidation from OH radical system such as advanced oxidation processes (AOPs). Thereafter, the high concentration of COD, color, and TSS can be removed. The general aim of the present investigation was to determine degradation of black liquor wastewater by using a combined coagulation and Fenton-like methods. In this research, we use Poly Aluminum Chloride (PAC) as a coagulant and FeCl3.6H2O and H2O2 for Fenton-like's reagent. The process was conducted in jar test at 200 rpm for 30 minutes and after that slowly mixed for 2 hours and left for sedimentation 24 hours. 50 ml black liquor was added with variation dose of 1-5% PAC, and 10 % Fenton-like reagent. Hydroxyl radical was generated by the Fenton-like's reagent (ratio FeCl3.6H2O : H2O2 was varied). The highest decolorization of black liquor 70 % was obtained under 5% PAC coagulant. The pH of the wastewater was reduced from 13.00 to 8.07 after the addition of the coagulant. The decolorization of original black liquor was approximately 58% through the Fenton-like process. The combination of PAC and Fenton-like reagent has able to enhance the decolorization of black liquor up to 97%.

  2. Does Lipid Profile Affect Thrombin Generation During Ramadan Fasting in Patients With Cardiovascular Risks?

    PubMed

    Sassi, Mouna; Chakroun, Taher; Chouchène, Saoussen; Hellara, Ilhem; Boubaker, Hamdi; Grissa, Mohamed Habib; Khochtali, Ines; Hassine, Mohsen; Addad, Faouzi; Elalamy, Ismail; Nouira, Semir

    2017-11-01

    There is evidence that diet and variation in lipid metabolism can influence blood coagulation, but little is known about the effect of Ramadan fasting on plasmatic coagulation pattern. We investigated the effect of Ramadan fasting on thrombin generation (TG) in patients with cardiovascular disease (CVD) risks, and we aimed to assess the effect of lipid profile on TG parameters. The study was conducted in 36 adults having at least 2 CVD risks and in 30 healthy controls. Coagulation pattern was assessed by both classical clotting times and TG test. A complete lipid profile was performed simultaneously. Patients were invited 2 times: 1 week before Ramadan and during the last week of the Ramadan. The TG parameters were not different in patients with CVD risks compared to healthy controls. Fasting had no effect on plasmatic coagulation parameters and on TG profile. Individual analysis of the mean rate index (MRI) of TG revealed 3 groups: group 1 with no modification of MRI, group 2 with a significant increase in MRI (81.64 nM/min vs 136.07 nM/min; P < .001), and group 3 with a significant decrease in MRI (125.27 nM/min vs 73.18 nM/min; P = .001). Only in group 2, a significant increase was observed in total cholesterol and low-density lipoprotein cholesterol. Changes in lipid profile during Ramadan fasting did not influence the global coagulation pattern in patients with CVD risks. Whereas, a significant increase in the propagation phase of TG was associated with a significant increase in cholesterol levels, which was not found with the other TG parameters.

  3. Some Hardware and Instrumentation Aspects of the Development of an Automation System for Jar Tests in Drinking Water Treatment

    PubMed Central

    2017-01-01

    The so-called Jar Test (JT) plays a vital role in the drinking water and wastewater treatments for establishing the dosage of flocculants and coagulant. This test is a well-proved laboratory instrumental procedure performed by trained personnel. In this work, a completely novel system for the automation and monitoring of a JT devoted to drinking water treatment is presented. It has been implemented using an industrial programmable controller and sensors and instruments specifically selected for this purpose. Once the parameters of the test have been entered, the stages that compose the JT (stirring, coagulant addition, etc.) are sequentially performed without human intervention. Moreover, all the involved measurements from sensors are collected and made accessible for continuous monitoring of the process. By means of the proposed system, the JT procedure is conducted fully automatically and can be locally and remotely monitored in real-time. Furthermore, the developed system constitutes a portable laboratory that offers advantageous features like scalability and transportability. The proposed system is described focusing on hardware and instrumentation aspects, and successful results are reported. PMID:29019943

  4. Purification of pulp and paper mill effluent using Eichornia crassipes.

    PubMed

    Yedla, S; Mitra, A; Bandyopadhyay, M

    2002-04-01

    Konark Pulp and Paper Industries Private Limited is a medium size industry producing 1600 m3 of wastewater a day. The existing water treatment system of the industry was found to be ineffective both in performance and economy. In the present study, a new system of treatment has been developed using water hyacinth Eichornia crassipes, coagulation by lime and alum, followed by rapid sand filtration. The performance efficiency of each unit viz. Eichornia treatment; coagulation with lime, with alum, and with lime:alum combinations, and filtration was studied. Water quality parameters considered were Biological Oxygen Demand, Chemical Oxygen Demand, Dissolve Oxygen, Total Dissolved Solids, turbidity, percentage transmission, and water colour. Based on the individual performance of each unit, a continuous system has been designed and was tested. The new system of treatment could treat the wastewater to the discharge standards and also was found economically feasible. Testing culture of fish (tilapia) proved that the treated water could be safely discharged into natural waters. All fish tested, survived and remained healthy throughout the period of testing. Culture of fish further improved the water quality.

  5. Some Hardware and Instrumentation Aspects of the Development of an Automation System for Jar Tests in Drinking Water Treatment.

    PubMed

    Calderón, Antonio José; González, Isaías

    2017-10-11

    The so-called Jar Test (JT) plays a vital role in the drinking water and wastewater treatments for establishing the dosage of flocculants and coagulant. This test is a well-proved laboratory instrumental procedure performed by trained personnel. In this work, a completely novel system for the automation and monitoring of a JT devoted to drinking water treatment is presented. It has been implemented using an industrial programmable controller and sensors and instruments specifically selected for this purpose. Once the parameters of the test have been entered, the stages that compose the JT (stirring, coagulant addition, etc.) are sequentially performed without human intervention. Moreover, all the involved measurements from sensors are collected and made accessible for continuous monitoring of the process. By means of the proposed system, the JT procedure is conducted fully automatically and can be locally and remotely monitored in real-time. Furthermore, the developed system constitutes a portable laboratory that offers advantageous features like scalability and transportability. The proposed system is described focusing on hardware and instrumentation aspects, and successful results are reported.

  6. [The implantation of bipolar coagulation to remove endometriosis foci].

    PubMed

    Sobkiewicz, S; Palatyński, A; Salata, I

    2001-05-01

    The paper compares the results of bipolar coagulation bey means of ERBE ICC 300 diatermy coagulator and WISAP endocoagulator. The results of both types of coagulation were assessed with reference to the changes occurring on peritoneum ligamenti sacro-uterini, Douglas pouch and ovary. The best results of endometriosis foci coagulation were obtained with bipolar ball at 20-30 W; no side effects or feelings of malaise were observed in patients just after the operation or over a longer period of convalescence.

  7. Investigation of a Brazilian tannery effluent by means of zebra fish (Danio rerio) embryo acute toxicity (FET) test.

    PubMed

    Rocha, Otávio Pelegrino; De Oliveira, Danielle Palma

    2017-01-01

    Tannery effluents consist of a complex chemical composition not only limited to primary pollutants, which also require biological detection as these compounds may produce adverse effects. The fish embryo toxicity (FET) test with Danio rerio is an alternative method in hazard and risk assessment for determination of chemical-mediated effects. The aim of this investigation was to use the FET test to detect compounds and consequent effects in Brazilian tannery effluents. Samples were collected from the inlet and outlet of the effluent treatment plant at a tannery located in Restinga, São Paulo, Brazil. The toxicological effects were assessed using FET assay for a period of 144 hr using indices such as (1) coagulation of fertilized eggs, (2) lack of detachment of tail-bud from yolk sac, (3) absence of spontaneous movement, (4) yolk sack edema, (5) malformation of the tail, (6) scoliosis, and (7) deformation of swim bladder in the embryos. Data showed that effluent treatment plant exposure produced acute toxicity in D. rerio embryos as evidenced by coagulation of fertilized eggs in up to 5% of all diluted samples 24 hr post fertilization for inlet effluent samples compared to 100% coagulation for outlet samples. Results demonstrated that these effects may not be attributed to metals, but to other non-detected components, such as dyes, pigments, biocides, carriers, surfactants, or other organic compounds that might be present in these complex mixtures. The use of D. rerio embryos was found to be useful as an additional tool for ecotoxicity testing to assess the potential environmental acute toxicity influence of tannery effluents.

  8. Effect of chitosan and coagulation factors on the wound repair phenotype of bioengineered blood clots.

    PubMed

    Hoemann, Caroline D; Marchand, Catherine; Rivard, Georges-Etienne; El-Gabalawy, Hani; Poubelle, Patrice E

    2017-11-01

    Controlling the blood clot phenotype in a surgically prepared wound is an evolving concept in scaffold-guided tissue engineering. Here, we investigated the effect of added chitosan (80% or 95% Degree of Deacetylation, DDA) or coagulation factors (recombinant human Factor VIIa, Tissue Factor, thrombin) on inflammatory factors released by blood clots. We tested the hypothesis that 80% DDA chitosan specifically enhances leukotriene B 4 (LTB 4 ) production. Human or rabbit whole blood was combined with isotonic chitosan solutions, coagulation factors, or lipopolysaccharide, cultured in vitro at 37°C, and after 4hours the serum was assayed for LTB 4 or inflammatory factors. Only 80% DDA chitosan clots produced around 15-fold more LTB 4 over other clots including 95% DDA chitosan clots. All serum contained high levels of PDGF-BB and CXCL8. Normal clots produced very low type I cytokines compared to lipopolysaccharide clots, with even lower IL-6 and IL-12 and more CCL3/CCL4 produced by chitosan clots. Coagulation factors had no detectable effect on clot phenotype. Conclusion In blood clots from healthy individuals, 80% DDA chitosan has a unique influence of inducing more LTB 4 , a potent neutrophil chemoattractant, with similar production of PDGF-BB and CXCL8, and lower type I cytokines, compared to whole blood clots. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. In-traffic air pollution exposure and CC16, blood coagulation, and inflammation markers in healthy adults.

    PubMed

    Zuurbier, Moniek; Hoek, Gerard; Oldenwening, Marieke; Meliefste, Kees; Krop, Esmeralda; van den Hazel, Peter; Brunekreef, Bert

    2011-10-01

    Exposure to traffic-related air pollution is a risk factor for cardiovascular events, probably involving mechanisms of inflammation and coagulation. Little is known about effects of the short exposures encountered while participating in traffic. The objective of the study was to examine effects of exposure of commuters to air pollution on cardiovascular biomarkers. Thirty-four healthy adult volunteers commuted for 2 hr by bus, car, or bicycle during the morning rush hour. During the commute, exposure to particle number, particulate matter (PM) ≤ 2.5 µm in aerodynamic diameter (PM2.5), PM ≤ 10 µm in diameter (PM10), and soot was measured. We estimated inhaled doses based on heart rate monitoring. Shortly before exposure and 6 hr after exposure, blood samples were taken and analyzed for CC16 (Clara cell protein 16), blood cell count, coagulation markers, and inflammation markers. Between June 2007 and June 2008, 352 pre- and postexposure blood samples were collected on 47 test days. We used mixed models to analyze the associations between exposure and changes in health parameters. We observed no consistent associations between the air pollution exposures and doses and the various biomarkers that we investigated. Air pollution exposure during commuting was not consistently associated with acute changes in inflammation markers, blood cell counts, or blood coagulation markers.

  10. Novel Al-doped carbon nanotubes with adsorption and coagulation promotion for organic pollutant removal.

    PubMed

    Kang, Dongjuan; Yu, Xiaolin; Ge, Maofa; Xiao, Feng; Xu, Hui

    2017-04-01

    Al-doped carbon nanotubes (Al-doped CNTs) were prepared as a multifunctional integrated material of adsorbent and coagulant aid for organic pollutant removal from aqueous solution. It was observed that aluminum species were dispersed homogeneously on the surface of CNTs, and mainly anchored onto defect structures of the CNTs. The introduction of aluminium efficiently improved adsorption ability for methyl orange (MO) onto the CNTs, and maximum adsorption capacity calculated from the Langmuir isotherm model can reach 69.7mg/g. The MO adsorption kinetics can be better described by the pseudo-second-order and pore diffusion kinetic models, and the diffusion of MO anions into pores of the Al-doped CNT adsorbent should be the rate-determining step. Thermodynamic analyses indicated that the adsorption of MO onto Al-CNTs-2.0 was endothermic and spontaneous. Moreover, adsorption capacity for MO on the Al-doped CNTs was evidently dependent on the CNT dose, solution pH and adsorbent dose. From the perspective of low-cost and multifunctional, suspension obtained during the Al-doped CNT adsorbent preparation, was tested as coagulant to remove humic acid (HA). A significant observation is that the suspension exhibited an excellent coagulation performance for HA, because abundant aluminous polymer and Al-doped CNTs existed in the suspension. Copyright © 2016. Published by Elsevier B.V.

  11. 21 CFR 864.5425 - Multipurpose system for in vitro coagulation studies.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Multipurpose system for in vitro coagulation... Hematology Devices § 864.5425 Multipurpose system for in vitro coagulation studies. (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated...

  12. 21 CFR 864.5425 - Multipurpose system for in vitro coagulation studies.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Multipurpose system for in vitro coagulation... Hematology Devices § 864.5425 Multipurpose system for in vitro coagulation studies. (a) Identification. A multipurpose system for in vitro coagulation studies is a device consisting of one automated or semiautomated...

  13. Application of response surface methodology (RSM) for optimizing coagulation process of paper recycling wastewater using Ocimum basilicum.

    PubMed

    Mosaddeghi, Mohammad Reza; Pajoum Shariati, Farshid; Vaziri Yazdi, Seyed Ali; Nabi Bidhendi, Gholamreza

    2018-06-21

    The wastewater produced in a pulp and paper industry is one of the most polluted industrial wastewaters, and therefore its treatment requires complex processes. One of the simple and feasible processes in pulp and paper wastewater treatment is coagulation and flocculation. Overusing a chemical coagulant can produce a large volume of sludge and increase costs and health concerns. Therefore, the use of natural and plant-based coagulants has been recently attracted the attention of researchers. One of the advantages of using Ocimum basilicum as a coagulant is a reduction in the amount of chemical coagulant required. In this study, the effect of basil mucilage has been investigated as a plant-based coagulant together with alum for treatment of paper recycling wastewater. Response surface methodology (RSM) was used to optimize the process of chemical coagulation based on a central composite rotatable design (CCRD). Quadratic models for colour reduction and TSS removal with coefficients of determination of R 2 >96 were obtained using the analysis of variance. Under optimal conditions, removal efficiencies of colour and total suspended solids (TSS) were 85% and 82%, respectively.

  14. A natural coagulant protein from Moringa oleifera: isolation, characterization, and potential use for water treatment

    NASA Astrophysics Data System (ADS)

    Choudhary, Manisha; Neogi, Sudarsan

    2017-10-01

    In developing countries pond water is still widely used for drinking and household purposes, which develops higher turbidity during rainy seasons and requires a large amount of chemical coagulants, and this leads to high cost of treatment. To mitigate this, it is important to find an economical and natural coagulant to treat turbid water. The present study is focused on using a plant based component as a natural coagulant that is sustainable and environment-friendly. This work focuses on the extraction, isolation and purification of a natural coagulant from seed kernels of Moringa oleifera to enhance its turbidity removal efficiency. The determination of themolecular weight of the purified proteins was done using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The active coagulant proteins were isolated using 30-60% and 60-80% saturation of ammonium sulfate. It was observed that proteins with molecular weight less than 36 kDa have superior coagulation activity. Turbidity removal efficiency of these active coagulant proteins was compared with alum. The possibility of using Moringa oleifera seeds as a natural antimicrobial agent was also investigated.

  15. Enhanced coagulation for improving coagulation performance and reducing residual aluminum combining polyaluminum chloride with diatomite.

    PubMed

    Hu, Wenchao; Wu, Chunde

    2016-01-01

    The feasibility of using enhanced coagulation, which combined polyaluminum chloride (PAC) with diatomite for improving coagulation performance and reducing the residual aluminum (Al), was discussed. The effects of PAC and diatomite dosage on the coagulation performance and residual Al were mainly investigated. Results demonstrated that the removal efficiencies of turbidity, dissolved organic carbon (DOC), and UV254 were significantly improved by the enhanced coagulation, compared with PAC coagulation alone. Meaningfully, the five forms of residual Al (total Al (TAl), total dissolved Al (TDAl), dissolved organic Al (DOAl), dissolved monomeric Al (DMAl), and dissolved organic monomeric Al (DOMAl)) all had different degrees of reduction in the presence of diatomite and achieved the lowest concentrations (0.185, 0.06, 0.053, 0.014, and 0 mg L(-1), respectively) at a PAC dose of 15 mg L(-1) and diatomite dose of 40 mg L(-1). In addition, when PAC was used as coagulant, the majority of residual Al existed in dissolved form (about 31.14-70.16%), and the content of DOMAl was small in the DMAl.

  16. [Team approaches to critical bleeding (massive bleeding and transfusion) - chairmen's introductory remarks. Questionnaire survey on current status of hospital clinical laboratories evaluating critical hemorrhage].

    PubMed

    Kino, Shuichi; Suwabe, Akira

    2014-12-01

    In 2007, "the Guidelines for Actions against Intraoperative Critical Hemorrhage" were established by the Japanese Society of Anaesthesiologists and the Japanese Society of Blood transfusion and Cell Therapy. The documentation of in-hospital procedures for critical hemorrhage, especially about how to select RBC units, has widely standardized hospital practice. Patients with intraoperative critical hemorrhage sometimes suffer from massive blood loss. In this situation, some patients develop coagulopathy. To treat them, we need to evaluate their coagulation status based on laboratory test results. So, we performed a nationwide questionnaire survey on the current status of hospital clinical laboratories evaluating critical hemorrhage. From the results of this survey, it was recommended that central hospital laboratories should try to reduce the turn-around time required to test for coagulation parameters as much as possible for appropriate substitution therapy. (Review).

  17. Lowering Low-Density Lipoprotein Particles in Plasma Using Dextran Sulphate Co-Precipitates Procoagulant Extracellular Vesicles.

    PubMed

    Wang, Jiong-Wei; Zhang, Ya-Nan; Sze, Siu Kwan; van de Weg, Sander M; Vernooij, Flora; Schoneveld, Arjan H; Tan, Sock-Hwee; Versteeg, Henri H; Timmers, Leo; Lam, Carolyn S P; de Kleijn, Dominique P V

    2017-12-29

    Plasma extracellular vesicles (EVs) are lipid membrane vesicles involved in several biological processes including coagulation. Both coagulation and lipid metabolism are strongly associated with cardiovascular events. Lowering very-low- and low-density lipoprotein ((V)LDL) particles via dextran sulphate LDL apheresis also removes coagulation proteins. It remains unknown, however, how coagulation proteins are removed in apheresis. We hypothesize that plasma EVs that contain high levels of coagulation proteins are concomitantly removed with (V)LDL particles by dextran sulphate apheresis. For this, we precipitated (V)LDL particles from human plasma with dextran sulphate and analyzed the abundance of coagulation proteins and EVs in the precipitate. Coagulation pathway proteins, as demonstrated by proteomics and a bead-based immunoassay, were over-represented in the (V)LDL precipitate. In this precipitate, both bilayer EVs and monolayer (V)LDL particles were observed by electron microscopy. Separation of EVs from (V)LDL particles using density gradient centrifugation revealed that almost all coagulation proteins were present in the EVs and not in the (V)LDL particles. These EVs also showed a strong procoagulant activity. Our study suggests that dextran sulphate used in LDL apheresis may remove procoagulant EVs concomitantly with (V)LDL particles, leading to a loss of coagulation proteins from the blood.

  18. Removal of natural organic matter in drinking water treatment by coagulation: A comprehensive review.

    PubMed

    Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko

    2018-01-01

    Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Tissue Factor Coagulant Activity is Regulated by the Plasma Membrane Microenvironment.

    PubMed

    Yu, Yuanjie; Böing, Anita N; Hau, Chi M; Hajji, Najat; Ruf, Wolfram; Sturk, Auguste; Nieuwland, Rienk

    2018-06-01

     Tissue factor (TF) can be present in a non-coagulant and coagulant form. Whether the coagulant activity is affected by the plasma membrane microenvironment is unexplored.  This article studies the presence and coagulant activity of human TF in plasma membrane micro-domains.  Plasma membranes were isolated from human MIA PaCa2 cells, MDA-MB-231 cells and human vascular smooth muscle cells by Percoll gradient ultracentrifugation after cell disruption. Plasma membranes were fractionated by OptiPrep gradient ultracentrifugation, and the presence of TF, flotillin, caveolin, clathrin, protein disulphide isomerase (PDI), TF pathway inhibitor (TFPI) and phosphatidylserine (PS) were determined.  Plasma membranes contain two detergent-resistant membrane (DRM) compartments differing in density and biochemical composition. High-density DRMs (DRM-H) have a density ( ρ ) of 1.15 to 1.20 g/mL and contain clathrin, whereas low-density DRMs (DRM-L) have a density between 1.09 and 1.13 g/mL and do not contain clathrin. Both DRMs contain TF, flotillin and caveolin. PDI is detectable in DRM-H, TFPI is not detectable in either DMR-H or DRM-L and PS is detectable in DRM-L. The DRM-H-associated TF (> 95% of the TF antigen) lacks detectable coagulant activity, whereas the DRM-L-associated TF triggers coagulation. This coagulant activity is inhibited by lactadherin and thus PS-dependent, but seemed insensitive to 16F16, an inhibitor of PDI.  Non-coagulant and coagulant TF are present within different types of DRMs in the plasma membrane, and the composition of these DRMs may affect the TF coagulant activity. Schattauer GmbH Stuttgart.

  20. Association of serologic and hematologic test results in dengue infant patients in RSUP. Dr. Hasan Sadikin Bandung

    NASA Astrophysics Data System (ADS)

    Alam, A.; Handayani, I.; Indrati, A. R.

    2018-03-01

    The incidence of Dengue virus infection is increasing every year,and the progression of the disease is faster towards severe manifestations in infants than in children and adults.The clinical appearance is still challenging to make for the diagnosis of dengue fever, so routine blood examination becomes one of thefurther enforcement efforts. The gold standard isconfirmatory tests for dengue, but this examination would be difficult in remote areas and also cost more. Research on serological testing and its association with routine blood testing in infant dengue-infected patients is still less publicized. The purpose of this study was to describe theconnection between serological and routine blood test results of infant dengue infection patients in RSUP Dr. Hasan Sadikin. Observational design in dengue 56 infants with 2-12 months age range examined serologic test and routine blood examination. The results showed that serological testing tended to be on routine blood tests. It can be from differences in routine blood tests such as hemoglobin, hematocrit, and platelets. Also, there was also no difference in routine blood profile between reactive and non-reactive IgM groups. It suggests that routine blood examination results are still lacking for the diagnosis of dengue.

  1. Evaluation of acute ecotoxicity removal from industrial wastewater using a battery of rapid bioassays.

    PubMed

    Dries, Jan; Daens, Dominique; Geuens, Luc; Blust, Ronny

    2014-01-01

    The present study compares conventional wastewater treatment technologies (coagulation-flocculation and activated sludge) and powdered activated carbon (PAC) treatment for the removal of acute ecotoxicity from wastewater generated by tank truck cleaning (TTC) processes. Ecotoxicity was assessed with a battery of four commercially available rapid biological toxicity testing systems, verified by the US Environmental Protection Agency. Chemical coagulation-flocculation of raw TTC wastewater had no impact on the inhibition of the bioluminescence by Vibrio fischeri (BioTox assay). Subsequent biological treatment with activated sludge without PAC resulted in BioTox inhibition-free effluent (<10% inhibition). In contrast, activated sludge treatment without PAC produced an effluent that significantly inhibited (>50%) (i) the bioluminescence by Photobacterium leiognathi (ToxScreen³ test kit), (ii) the photosynthesis by the green algae Chlorella vulgaris (LuminoTox SAPS test kit), and (iii) the particle ingestion by the crustacean Thamnocephalus platyurus (Rapidtoxkit test kit). The lowest inhibition was measured after activated sludge treatment with the highest PAC dose (400 mg/L), demonstrating the effectiveness of PAC treatment for ecotoxicity removal from TTC wastewater. In conclusion, the combination of bioassays applied in the present study represents a promising test battery for rapid ecotoxicty assessment in wastewater treatment.

  2. The effects of transport by car on coagulation tests.

    PubMed

    Ergin, Merve; Erdogan, Serpil; Akturk, Onur; Erel, Ozcan

    2017-10-26

    This research investigated the effects of the transport of blood samples between centers/laboratories by car on coagulation tests. Five tubes of blood samples were taken from 20 healthy volunteers. The samples consisted of a baseline (control) group, centrifuged and noncentrifuged transported samples; centrifuged and noncentrifuged untransported samples. The groups of centrifuged and noncentrifuged samples were transported by car for 2 h. The centrifuged and noncentrifuged untransported samples were incubated in the laboratory until the transported samples arrived. Prothrombin time (PT) and activated partial thromboplastin time (APTT) tests were conducted for all samples. Significant differences between the baseline group and the centrifuged and noncentrifuged transported samples and the noncentrifuged untransported samples were found for APTT levels (p<0.05, for all). In addition, significant mean percentage differences in PT values were found between the baseline group and the noncentrifuged transported samples (p<0.001) and the noncentrifuged untransported samples (p=0.005). The mean level of PT in the noncentrifuged transported samples was outside the upper limit of the clinical decision level. Noncentrifuged transported samples showed clinically significant differences in PT test results that may have stemmed from mechanical agitation during transportation. Therefore, we recommend not transporting noncentrifuged specimens for PT testing by car.

  3. Removal of strontium from drinking water by conventional treatment and lime softening in bench-scale studies.

    PubMed

    O'Donnell, Alissa J; Lytle, Darren A; Harmon, Stephen; Vu, Kevin; Chait, Hannah; Dionysiou, Dionysios D

    2016-10-15

    The United States Environmental Protection Agency Contaminant Candidate List 3 lists strontium as a contaminant for potential regulatory consideration in drinking water. Very limited data is available on strontium removal from drinking water and as a result, there is an immediate need for treatment information. The objective of this work is to evaluate the effectiveness of coagulation/filtration and lime-soda ash softening treatment methods to remove strontium from surface and ground waters. Coagulation/filtration jar test results on natural waters showed that conventional treatment with aluminum and iron coagulants were able to achieve only 12% and 5.9% strontium removal, while lime softening removed as high as 78% from natural strontium-containing ground water. Controlled batch experiments on synthetic water showed that strontium removal during the lime-soda ash softening was affected by pH, calcium concentration and dissolved inorganic carbon concentration. In all softening jar tests, the final strontium concentration was directly related to the initial strontium concentration and the removal of strontium was directly associated with calcium removal. Precipitated solids showed well-formed crystals or agglomerates of mixed solids, two polymorphs of calcium carbonate (vaterite and calcite), and strontianite, depending on initial water quality conditions. X-ray diffraction analysis suggested that strontium was likely incorporated in the calcium carbonate crystal lattice and was likely responsible for removal during lime softening. Copyright © 2016. Published by Elsevier Ltd.

  4. Biomass fly ashes as low-cost chemical agents for Pb removal from synthetic and industrial wastewaters.

    PubMed

    Barbosa, Rui; Lapa, Nuno; Lopes, Helena; Günther, Annika; Dias, Diogo; Mendes, Benilde

    2014-06-15

    The main aim of this work was to study the removal efficiency of Pb from synthetic and industrial wastewaters by using biomass fly ashes. The biomass fly ashes were produced in a biomass boiler of a pulp and paper industry. Three concentrations of Pb(2+) were tested in the synthetic wastewater (1, 10 and 1000 mg Pb/L). Moreover, two different wastewaters were collected in an industrial wastewater treatment plant (IWWTP) of an industry of lead-acid batteries: (i) wastewater of the equalization tank, and (ii) IWWTP effluent. All the wastewaters were submitted to coagulation-flocculation tests with a wide range of biomass fly ashes dosage (expressed as Solid/Liquid - S/L - ratios). All supernatants were characterized for chemical and ecotoxicological parameters. The use of biomass fly ashes has reduced significantly the Pb concentration in the synthetic wastewater and in the wastewaters collected in the IWWTP. For example, the definitive coagulation-flocculation assays performed over the IWWTP effluent presented a very low concentration of Pb (0.35 mg/L) for the S/L ratio of 1.23 g/L. Globally, the ecotoxicological characterization of the supernatants resulting from the coagulation-flocculation assays of all wastewaters has indicated an overall reduction on the ecotoxicity of the crude wastewaters, due to the removal of Pb. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Dust coagulation. [in interstellar medium observed in stellar envelopes and planetary disks

    NASA Technical Reports Server (NTRS)

    Chokshi, Arati; Tielens, A. G. G. M.; Hollenbach, D.

    1993-01-01

    The microphysics of coagulation between two, colliding, smooth, spherical grains in the elastic limit is investigated, and the criteria for sticking as a function of particle sizes, collision velocities, elastic properties, and binding energy are calculated. Critical relative velocities for coagulation were evaluated as a function of grain sizes for solicate, icy, and carbonaceous grains. It is concluded that efficient coagulation requires coverage of grain cores by an icy grain mantle. In this case, coagulation leads to only a doubling of the mass of a large grain within a dense core lifetime. It is concluded that coagulation can have a dramatic effect on the visible and, particularly, the UV portion of the extinction curve in dense clouds and on their IR spectrum.

  6. Measurement of Blood Coagulation Factor Synthesis in Cultures of Human Hepatocytes.

    PubMed

    Heinz, Stefan; Braspenning, Joris

    2015-01-01

    An important function of the liver is the synthesis and secretion of blood coagulation factors. Within the liver, hepatocytes are involved in the synthesis of most blood coagulation factors, such as fibrinogen, prothrombin, factor V, VII, IX, X, XI, XII, as well as protein C and S, and antithrombin, whereas liver sinusoidal endothelial cells produce factor VIII and von Willebrand factor. Here, we describe methods for the detection and quantification of most blood coagulation factors in hepatocytes in vitro. Hepatocyte cultures indeed provide a valuable tool to study blood coagulation factors. In addition, the generation and expansion of hepatocytes or hepatocyte-like cells may be used in future for cell-based therapies of liver diseases, including blood coagulation factor deficiencies.

  7. Reduced Transfusion During OLT by POC Coagulation Management and TEG Functional Fibrinogen: A Retrospective Observational Study.

    PubMed

    De Pietri, Lesley; Ragusa, Francesca; Deleuterio, Annalisa; Begliomini, Bruno; Serra, Valentina

    2016-01-01

    Patients undergoing orthotopic liver transplantation are at high risk of bleeding complications. Several Authors have shown that thromboelastography (TEG)-based coagulation management and the administration of fibrinogen concentrate reduce the need for blood transfusion. We conducted a single-center, retrospective cohort observational study (Modena Polyclinic, Italy) on 386 consecutive patients undergoing liver transplantation. We assessed the impact on resource consumption and patient survival after the introduction of a new TEG-based transfusion algorithm, requiring also the introduction of the fibrinogen functional thromboelastography test and a maximum amplitude of functional fibrinogen thromboelastography transfusion cutoff (7 mm) to direct in administering fibrinogen (2012-2014, n = 118) compared with a purely TEG-based algorithm previously used (2005-2011, n = 268). After 2012, there was a significant decrease in the use of homologous blood (1502 ± 1376 vs 794 ± 717 mL, P < 0.001), fresh frozen plasma (537 ± 798 vs 98 ± 375 mL, P < 0.001), and platelets (158 ± 280 vs 75 ± 148 mL, P < 0.005), whereas the use of fibrinogen increased (0.1 ± 0.5 vs 1.4 ± 1.8 g, P < 0.001). There were no significant differences in 30-day and 6-month survival between the 2 groups. The implementation of a new coagulation management method featuring the addition of the fibrinogen functional thromboelastography test to the TEG test according to an algorithm which provides for the administration of fibrinogen has helped in reducing the need for transfusion in patients undergoing liver transplantation with no impact on their survival.

  8. What Makes Me Screen for HIV? Perceived Barriers and Facilitators to Conducting Recommended Routine HIV Testing among Primary care Physicians in the Southeastern United States

    PubMed Central

    White, Becky L.; Walsh, Joan; Rayasam, Swati; Pathman, Donald E.; Adimora, Adaora A.; Golin, Carol E.

    2015-01-01

    The Centers for Disease Control and Prevention have recommended routinely testing patients (aged 13–64) for HIV since 2006. However, many physicians do not routinely test. From January 2011- March 2012, we conducted 18 in-depth individual interviews and explored primary care physicians’ perceptions of barriers and facilitators to implementing routine HIV testing in North Carolina. Physicians’ comments were categorized thematically and fell into five groups: policy, community, practice, physician and patient. Lack of universal reimbursement was identified as the major policy barrier. Participants believed endorsement from the United States Preventive Services Tasks Force would facilitate adoption of routine HIV testing policies. Physicians reported HIV/AIDS stigma, socially conservative communities, lack of confidentiality, and rural geography as community barriers. Physicians believed public HIV testing campaigns would legitimize testing and decrease stigma in communities. Physicians cited time constraints and competing clinical priorities as physician barriers that could be overcome by delegating testing to nursing staff. HIV test refusal, low HIV risk perception, and stigma emerged as patient barriers. Physicians recommended adoption of routine HIV testing for all patients to facilitate and destigmatize testing. Physicians continue to experience a variety of barriers when implementing routine HIV testing in primary care settings. Our findings support multilevel approaches to enhance physician routine HIV testing in primary care settings. PMID:24643412

  9. [Topography structure and flocculation mechanism of polymeric phosphate ferric sulfate (PPFS)].

    PubMed

    Zheng, Huai-li; Zhang, Hui-qin; Jiang, Shao-jie; Li, Fang; Jiao, Shi-jun; Fang, Hui-li

    2011-05-01

    Characteristics of polymeric phosphate ferric sulfate (PPFS) were investigated using FTIR (Fourier transform infrared spectrometer), XRD (X-ray diffraction) and SEM (scanning electron microscope) in the present study. The formed PPFS structure and morphology were stereo meshwork, which was clustered and close to coral reef, synthesis of high charge density, bioactive polyhydroxy and mixed polynuclear complex PPFS. The results showed that charge neutralization of PPFS had not played a decisive role in the coagulation beaker test and the zeta potential proved that PPFS was largely affected by bridging and netting sweep. Therefore, the coagulation mechanisms of PPFS were mainly composed of charge neutralization, adsorption bridging and netting sweep mechanisms.

  10. 0-6638: performance testing of coagulants to reduce stormwater runoff turbidity : [project summary].

    DOT National Transportation Integrated Search

    2013-08-01

    During the last two decades, policy makers have : increasingly recognized that water quality is : adversely affected by sediment-laden : stormwater discharge from construction sites. : On December 1, 2009, the U.S. Environmental : Protection Agency (...

  11. Performance testing of coagulants to reduce stormwater runoff turbidity.

    DOT National Transportation Integrated Search

    2014-05-01

    On December 1, 2009, the US Environmental Protection Agency (EPA) published a rule in the Federal : Register establishing non-numeric and, for the first time, numeric effluent limitation guidelines (ELGs). The : numeric ELGs included a turbidity limi...

  12. The Coags Uncomplicated App: Fulfilling Educational Gaps Around Diagnosis and Laboratory Testing of Coagulation Disorders.

    PubMed

    Kessler, Craig; Peerschke, Ellinor I; Chitlur, Meera B; Kulkarni, Roshni; Holot, Natalia; Cooper, David L

    2017-04-18

    Patients with coagulation disorders may present to a variety of physician specialties; however, accurate and efficient diagnosis can be challenging for physicians not specialized in hematology, due to identified gaps in knowledge around appropriate laboratory assays and interpretation of test results. Coags Uncomplicated was developed to fill this unmet educational need by increasing practical knowledge of coagulation disorders among nonexpert physicians and other health care professionals (HCPs) in a point-of-care (POC) setting. The aim of this study was to assess patterns of use of the mobile app Coags Uncomplicated, a tool designed to support education regarding accurate and efficient diagnosis of bleeding disorders. App metrics were obtained by tracking registered user data. Additionally, a survey was distributed to registered users, to assess circumstances and frequency of use. The most common specialties of 7596 registered US users were hematology-oncology (n=1534, 20.19%), hematology (n=1014, 13.35%), and emergency medicine (n=1222, 16.09%); most identified as physicians (n=4082, 53.74%). Specialties accounting for the greatest numbers of screen views were hematology-oncology (99,390 views), hematology (47,808 views), emergency medicine (23,121 views), and internal medicine (22,586 views). The most common diagnostic endpoints reached were disseminated intravascular coagulation (DIC; 2713 times), liver disease effect (2108 times), and vitamin K deficiency (1584 times). Of 3424 users asked to take the survey, 262 responded (7.65%); most were physicians in direct clinical care (71%) and specialized in hematology-oncology (39%) or emergency medicine (21%). Most frequent use was reported by hematologists (69%, ≥6 times) and hematologists-oncologists (38%, ≥6 times). Most physicians (89.2%) reported using the app for patient-case-related education around appropriate use of laboratory tests in diagnostic evaluation. Physicians rated Lab Value Analyzer (mean 4.43) and Lab Test Algorithm (mean 4.46) tools highly on a 5-point "how helpful" scale and were likely to recommend the app to colleagues. App use among physicians and other HCPs is consistent with value as a POC educational tool, which may facilitate differential diagnoses and appropriate early consultation with hematologists. ©Craig Kessler, Ellinor I Peerschke, Meera B Chitlur, Roshni Kulkarni, Natalia Holot, David L Cooper. Originally published in JMIR Medical Education (http://mededu.jmir.org), 18.04.2017.

  13. A Novel Role for Pro-Coagulant Microvesicles in the Early Host Defense against Streptococcus pyogenes

    PubMed Central

    Oehmcke, Sonja; Westman, Johannes; Malmström, Johan; Mörgelin, Matthias; Olin, Anders I.; Kreikemeyer, Bernd; Herwald, Heiko

    2013-01-01

    Previous studies have shown that stimulation of whole blood or peripheral blood mononuclear cells with bacterial virulence factors results in the sequestration of pro-coagulant microvesicles (MVs). These particles explore their clotting activity via the extrinsic and intrinsic pathway of coagulation; however, their pathophysiological role in infectious diseases remains enigmatic. Here we describe that the interaction of pro-coagulant MVs with bacteria of the species Streptococcus pyogenes is part of the early immune response to the invading pathogen. As shown by negative staining electron microscopy and clotting assays, pro-coagulant MVs bind in the presence of plasma to the bacterial surface. Fibrinogen was identified as a linker that, through binding to the M1 protein of S. pyogenes, allows the opsonization of the bacteria by MVs. Surface plasmon resonance analysis revealed a strong interaction between pro-coagulant MVs and fibrinogen with a KD value in the nanomolar range. When performing a mass-spectrometry-based strategy to determine the protein quantity, a significant up-regulation of the fibrinogen-binding integrins CD18 and CD11b on pro-coagulant MVs was recorded. Finally we show that plasma clots induced by pro-coagulant MVs are able to prevent bacterial dissemination and possess antimicrobial activity. These findings were confirmed by in vivo experiments, as local treatment with pro-coagulant MVs dampens bacterial spreading to other organs and improved survival in an invasive streptococcal mouse model of infection. Taken together, our data implicate that pro-coagulant MVs play an important role in the early response of the innate immune system in infectious diseases. PMID:23935504

  14. Trihalomethanes (THMs) precursor fractions removal by coagulation and adsorption for bio-treated municipal wastewater: Molecular weight, hydrophobicity/hydrophily and fluorescence.

    PubMed

    Han, Qi; Yan, Han; Zhang, Feng; Xue, Nan; Wang, Yan; Chu, Yongbao; Gao, Baoyu

    2015-10-30

    Due to concerns over health risk of disinfection byproducts (DBPs), removal of trihalomethanes (THMs) precursor from bio-treated wastewater by coagulation and adsorption was investigated in this study. Ultrafiltration (UF) membranes and nonionic resins were applied to fractionate THMs precursor into various molecular weight (MW) fractions and hydrophobic/hydrophilic fractions. Characteristics of coagulated water and adsorbed water were evaluated by the three-dimensional excitation and emission matrix (3DEEM) fluorescence spectroscopy. Results showed that coagulation and adsorption were suitable for removing different hydrophobic/hydrophilic and fluorescent fractions. Coagulation decreased THMs concentration in hydrophobic acids (HoA) fraction from 59 μg/L to 39 μg/L, while the lowest THMs concentration (9 μg/L) in hydrophilic substances (HiS) fraction was obtained in adsorbed water. However, both coagulation and adsorption were ineffective for removing fractions with MW<5 kDa. Although coagulation and adsorption processes could reduce THMs formation, some specific THMs formation potential (STHMFP) in residual dissolved organic matter (DOM) fractions increased in this study. Hydrophobic acid and hydrophilic fractions increased after coagulation treatment, and low MW and hydrophobic fractions increased after adsorption treatment. In addition, active carbon adsorbed more organic matter than coagulant, but brominated disinfection byproducts (Br-DBPs) in adsorbed water turned to the major THMs species after chlorination. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode

    PubMed Central

    Dai, Hongya; Chen, Fei; Yan, Sijing; Ding, Xiaoya; Ma, Dazhao; Wen, Jing; Xu, Die; Zou, Jianzhong

    2017-01-01

    Background The aim of this study was to investigate the feasibility of the application of high-intensity focused ultrasound (HIFU) hat-type ablation mode in in vitro and in vivo models, and to compare the ablation effects of different parameter combinations. Material/Methods HIFU hat-type ablation was performed in isolated bovine liver tissue and in the liver tissue in living rabbits, and the coagulative necrosis for different parameter combinations (plane angles and irradiation order) was investigated. We also analyzed and compared the ablation effects of traditional ablation and hat-type ablation modes. Coagulative necrosis morphology was detected with TTC staining, and the coagulative necrosis volume and energy efficiency factor (EEF) were calculated and compared. Results Coagulative necrosis was observed in all the ablated groups, and the coagulative necrosis volume was much larger than the irradiation area. The coagulative necrosis induced by the hat-type ablation was more regular and controllable than the traditional ablation. The angles between the ablation planes determined the coagulative necrosis morphology, but did not affect the coagulative necrosis volume. Moreover, the irradiation order significantly influenced the coagulative necrosis. Importantly, under certain conditions, hat-type ablation achieved higher efficiency compared with the traditional ablation mode. Conclusions Compared with the traditional ablation mode, HIFU hat-type ablation effectively shortened the irradiation time, reduced the over-accumulation of energy, and increased the HIFU ablation efficiency. PMID:28699626

  16. In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode.

    PubMed

    Dai, Hongya; Chen, Fei; Yan, Sijing; Ding, Xiaoya; Ma, Dazhao; Wen, Jing; Xu, Die; Zou, Jianzhong

    2017-07-12

    BACKGROUND The aim of this study was to investigate the feasibility of the application of high-intensity focused ultrasound (HIFU) hat-type ablation mode in in vitro and in vivo models, and to compare the ablation effects of different parameter combinations. MATERIAL AND METHODS HIFU hat-type ablation was performed in isolated bovine liver tissue and in the liver tissue in living rabbits, and the coagulative necrosis for different parameter combinations (plane angles and irradiation order) was investigated. We also analyzed and compared the ablation effects of traditional ablation and hat-type ablation modes. Coagulative necrosis morphology was detected with TTC staining, and the coagulative necrosis volume and energy efficiency factor (EEF) were calculated and compared. RESULTS Coagulative necrosis was observed in all the ablated groups, and the coagulative necrosis volume was much larger than the irradiation area. The coagulative necrosis induced by the hat-type ablation was more regular and controllable than the traditional ablation. The angles between the ablation planes determined the coagulative necrosis morphology, but did not affect the coagulative necrosis volume. Moreover, the irradiation order significantly influenced the coagulative necrosis. Importantly, under certain conditions, hat-type ablation achieved higher efficiency compared with the traditional ablation mode. CONCLUSIONS Compared with the traditional ablation mode, HIFU hat-type ablation effectively shortened the irradiation time, reduced the over-accumulation of energy, and increased the HIFU ablation efficiency.

  17. [Effect of ferrate preoxidation on coagulation of Songhua River].

    PubMed

    Li, Chun-juan; Ma, Jun; Liang, Tao

    2008-06-01

    The preoxidation of polluted surface water with ferrate was conducted with respect to its impact on the following coagulation. It can be seen that UV254-absorbance, turbidity and TOC substantially decreased by 36.7%, 80.2%, 31.1%, respectively, after coagulation, without ferrate preoxidation, and by 63.3%, 89.6%, 37.0%, respectively, after coagulation, with ferrate preoxidation. It is noted that NH4+-N concentration is increased by 17% after coagulation with ferrate. This phenomenon can be explained by the fact that organics containing nitrogen in raw water were partly oxidized to inorganic nitrogen by ferrate preoxidation. After coagulation, AOC and AOC/TOC are increased from 998 microg x L(-1) to 1241 microg x L(-1), from 28.4% to 38.7%, respectively, by ferrate preoxidation. AOC-P17/AOC after coagulation is up to 83% with ferrate preoxidation. These suggest that preoxidation with ferrate promoted the biodegradation of organics with substantial increases of AOC, AOC/TOC. The results indicate that the concentration of organics with relative molecular mass (Mr) of 10000-100000 and less than 500 were substantially increased after the raw water was coagulated with ferrate preoxidation, which suggested that some high molecular weight organic substances were broken into smaller ones during ferrate preoxidation. After coagulation, organics of less than Mr = 500 in TOC are increased up to 65.0% with preoxidation from 38.9% without ferrate preoxidation. These oxidation products are biodegradable.

  18. The role of protease-activated receptors PAR-1 and PAR-2 in the repair of 16HBE 14o(-) epithelial cell monolayers in vitro.

    PubMed

    Ewen, D; Clarke, S L; Smith, J R; Berger, C; Salmon, G; Trevethick, M; Shute, J K

    2010-03-01

    We recently reported that repair following mechanical wounding of epithelial cell layers in vitro is dependent on fibrin formation and the activity of locally expressed coagulation cascade proteins. Serine proteases of the coagulation cascade are an important group of protease-activated receptor (PAR) activators and PAR-1 to 4 are expressed by the normal bronchial epithelium. We tested the hypothesis that activation of PAR-1 and PAR-2 by coagulation cascade proteases stimulates epithelial repair via effects on fibrin formation. Using mechanically wounded 16HBE 14o(-) epithelial cell layers in culture, we investigated the effect of PAR-1 and PAR-2 agonist peptides, control partially scrambled peptides and PAR-neutralizing antibodies on the rate of repair and fibrin formation. Coagulation factors in culture supernatants were measured by immunoblot. RT-PCR was used to investigate PAR-1, PAR-2 and PGE2 receptor (EP-1 to EP-4) expression in this model and qRT-PCR to quantify responses to wounding. Additionally, we investigated the effect of exogenously added factor Xa (FXa) and neutrophil elastase and the influence of PGE2 and indomethacin on the repair response. PAR-1 and PAR-2 peptide agonists stimulated the rate of repair and enhanced the formation of a fibrin provisional matrix to support the repair process. Conversely, PAR-neutralizing antibodies inhibited repair. Under serum-free culture conditions, 16HBE 14o(-) cells expressed EP-2 and EP-3, but not EP-1 or EP-4, receptors. Wounding induced an increased expression of EP-3 but did not alter EP-2, PAR-1 or PAR-2 expression. In the absence of PAR agonists, there was no evidence for a role for PGE2 in fibrin formation or the repair process. Indomethacin attenuated fibrin formation in wounded cultures only in the presence of the PAR-2 peptide. FXa stimulated epithelial repair while neutrophil elastase reduced the levels of coagulation factors and inhibited repair. Locally expressed serine proteases of the coagulation cascade activate PAR-1 and PAR-2 to enhance fibrin formation and bronchial epithelial repair.

  19. Characterization of core/shell Cu/Ag nanopowders synthesized by electrochemistry and assessment of their impact on hemolysis, platelet aggregation, and coagulation on human blood for potential wound dressing use

    NASA Astrophysics Data System (ADS)

    Laloy, Julie; Haguet, Hélène; Alpan, Lutfiye; Mancier, Valérie; Mejia, Jorge; Levi, Samuel; Dogné, Jean-Michel; Lucas, Stéphane; Rousse, Céline; Fricoteaux, Patrick

    2017-08-01

    Copper/silver core/shell nanopowders with different metal ratio have been elaborated by electrochemistry (ultrasound-assisted electrolysis followed by a displacement reaction). Characterization was performed by several methods (X-ray diffraction, scanning electron microscope, energy-dispersive X-ray spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, centrifugal liquid sedimentation, and zeta potential measurements). The mean diameter of all nanoparticles is around 10 nm. The impact of each nanopowder on hemolysis, platelet aggregation, and coagulation has been studied on whole human blood. Hemolysis assays were performed with spectrophotometric measurement and platelet aggregation, with light transmission aggregometry and was compared to Cu/Pt core/shell nanoparticles with similar size as negative control. Calibrated thrombin generation test has been used for a coagulation study. They neither impact platelet aggregation nor hemolysis and have a procoagulant effect whatever their composition (i.e., metal ratio). These results highlight that such nanopowders have a potential use in medical applications (e.g., wound dressing).

  20. Application of chemical coagulation aids for the removal of suspended solids (TSS) and phosphorus from the microscreen effluent discharge of an intensive recirculating aquaculture system

    USGS Publications Warehouse

    Ebeling, J.M.; Ogden, S.R.; Sibrell, P.L.; Rishel, K.L.

    2004-01-01

    An evaluation of two commonly used coagulation-flocculation aids (alum and ferric chloride) was conducted to determine optimum conditions for treating the backwash effluent from microscreen filters in an intensive recirculating aquaculture system. Tests were carried out to evaluate the dosages and conditions (mixing and flocculation stirring speeds, durations, and settling times) required to achieve optimum waste capture. The orthophosphate removal efficiency for alum and ferric chloride were greater than 90% at a dosage of 60 mg/L. Optimum turbidity removal was achieved with a 60-mg/L dosage for both alum and ferric chloride. Both alum and ferric chloride demonstrated excellent removal of suspended solids from initial total suspended solid values of approximately 320 mg/L to approximately 10 mg/L at a dosage of 60 mg/L. Flocculation and mixing speed and duration played only a minor role in the removal efficiencies for both orthophosphates and suspended solids. Both coagulation-flocculation aids also exhibited excellent settling characteristics, with the majority of the floc quickly settling out in the first 5 min.

Top