Sample records for routine laboratory testing

  1. [How to Interpret and Use Routine Laboratory Data--Our Methods to Interpret Routine Laboratory Data--Chairmen's Introductory Remarks].

    PubMed

    Honda, Takayuki; Tozuka, Minoru

    2015-09-01

    In the reversed clinicopathological conference (R-CPC), three specialists in laboratory medicine interpreted routine laboratory data independently in order to understand the detailed state of a patient. R-CPC is an educational method to use laboratory data appropriately, and it is also important to select differential diagnoses in a process of clinical reasoning in addition to the present illness and physical examination. Routine laboratory tests can be performed repeatedly at a relatively low cost, and their time-series analysis can be performed. Interpretation of routine laboratory data is almost the same as taking physical findings. General findings are initially checked and then the state of each organ is examined. Although routine laboratory tests cost little, we can gain much more information from them about the patient than physical examinations.

  2. Routine admission laboratory testing for general medical patients.

    PubMed

    Hubbell, F A; Frye, E B; Akin, B V; Rucker, L

    1988-06-01

    We evaluated the usefulness of commonly ordered routine admission laboratory tests in 301 patients admitted consecutively to the internal medicine wards of a university teaching hospital. Using a consensus analysis approach, three Department of Medicine faculty members reviewed the charts of admitted patients to determine the impact of the test results on patient care. The evaluated tests were the urinalysis, hematocrit, white blood cell count, platelet count, six-factor automated multiple analysis (serum sodium, potassium, chloride, bicarbonate, glucose, and blood urea nitrogen), prothrombin time, partial thromboplastin time, chest x-ray, and electrocardiogram. Forty-five percent of the 3,684 tests were ordered for patients without recognizable medical indications. Twelve percent of these routine tests were abnormal, 5% led to additional laboratory testing, but only 0.5% led to change in the treatment of patients. We conclude that the impact of routine admission laboratory testing on patient care is very small and that there is little justification for ordering tests solely because of hospital admission.

  3. Laboratory and clinical evaluation of on-site urine drug testing.

    PubMed

    Beck, Olof; Carlsson, Sten; Tusic, Marinela; Olsson, Robert; Franzen, Lisa; Hulten, Peter

    2014-11-01

    Products for on-site urine drug testing offer the possibility to perform screening for drugs of abuse directly at the point-of-care. This is a well-established routine in emergency and dependency clinics but further evaluation of performance is needed due to inherent limitations with the available products. Urine drug testing by an on-site product was compared with routine laboratory methods. First, on-site testing was performed at the laboratory in addition to the routine method. Second, the on-site testing was performed at a dependency clinic and urine samples were subsequently sent to the laboratory for additional analytical investigation. The on-site testing products did not perform with assigned cut-off levels. The subjective reading between the presence of a spot (i.e. negative test result) being present or no spot (positive result) was difficult in 3.2% of the cases, and occurred for all parameters. The tests performed more accurately in drug negative samples (specificity 96%) but less accurately for detecting positives (sensitivity 79%). Of all incorrect results by the on-site test the proportion of false negatives was 42%. The overall agreement between on-site and laboratory testing was 95% in the laboratory study and 98% in the clinical study. Although a high degree of agreement was observed between on-site and routine laboratory urine drug testing, the performance of on-site testing was not acceptable due to significant number of false negative results. The limited sensitivity of on-site testing compared to laboratory testing reduces the applicability of these tests.

  4. Effect of Social Comparison Feedback on Laboratory Test Ordering for Hospitalized Patients: A Randomized Controlled Trial.

    PubMed

    Ryskina, Kira; Jessica Dine, C; Gitelman, Yevgeniy; Leri, Damien; Patel, Mitesh; Kurtzman, Gregory; Lin, Lisa Y; Epstein, Andrew J

    2018-05-22

    Social comparison feedback is an increasingly popular strategy that uses performance report cards to modify physician behavior. Our objective was to test the effect of such feedback on the ordering of routine laboratory tests for hospitalized patients, a practice considered overused. This was a single-blinded randomized controlled trial. Between January and June 2016, physicians on six general medicine teams at the Hospital of the University of Pennsylvania were cluster randomized with equal allocation to two arms: (1) those e-mailed a summary of their routine laboratory test ordering vs. the service average for the prior week, linked to a continuously updated personalized dashboard containing patient-level details, and snapshot of the dashboard and (2) those who did not receive the intervention. The primary outcome was the count of routine laboratory test orders placed by a physician per patient-day. We modeled the count of orders by each physician per patient-day after the intervention as a function of trial arm and the physician's order count before the intervention. The count outcome was modeled using negative binomial models with adjustment for clustering within teams. One hundred and fourteen interns and residents participated. We did not observe a statistically significant difference in adjusted reduction in routine laboratory ordering between the intervention and control physicians (physicians in the intervention group ordered 0.14 fewer tests per patient-day than physicians in the control group, 95% CI - 0.56 to 0.27, p = 0.50). Physicians whose absolute ordering rate deviated from the peer rate by more than 1.0 laboratory test per patient-day reduced their laboratory ordering by 0.80 orders per patient-day (95% CI - 1.58 to - 0.02, p = 0.04). Personalized social comparison feedback on routine laboratory ordering did not change targeted behavior among physicians, although there was a significant decrease in orders among participants who deviated more from the peer rate. Clinicaltrials.gov registration: #NCT02330289.

  5. Simpler score of routine laboratory tests predicts liver fibrosis in patients with chronic hepatitis B.

    PubMed

    Zhou, Kun; Gao, Chun-Fang; Zhao, Yun-Peng; Liu, Hai-Lin; Zheng, Rui-Dan; Xian, Jian-Chun; Xu, Hong-Tao; Mao, Yi-Min; Zeng, Min-De; Lu, Lun-Gen

    2010-09-01

    In recent years, a great interest has been dedicated to the development of noninvasive predictive models to substitute liver biopsy for fibrosis assessment and follow-up. Our aim was to provide a simpler model consisting of routine laboratory markers for predicting liver fibrosis in patients chronically infected with hepatitis B virus (HBV) in order to optimize their clinical management. Liver fibrosis was staged in 386 chronic HBV carriers who underwent liver biopsy and routine laboratory testing. Correlations between routine laboratory markers and fibrosis stage were statistically assessed. After logistic regression analysis, a novel predictive model was constructed. This S index was validated in an independent cohort of 146 chronic HBV carriers in comparison to the SLFG model, Fibrometer, Hepascore, Hui model, Forns score and APRI using receiver operating characteristic (ROC) curves. The diagnostic values of each marker panels were better than single routine laboratory markers. The S index consisting of gamma-glutamyltransferase (GGT), platelets (PLT) and albumin (ALB) (S-index: 1000 x GGT/(PLT x ALB(2))) had a higher diagnostic accuracy in predicting degree of fibrosis than any other mathematical model tested. The areas under the ROC curves (AUROC) were 0.812 and 0.890 for predicting significant fibrosis and cirrhosis in the validation cohort, respectively. The S index, a simpler mathematical model consisting of routine laboratory markers predicts significant fibrosis and cirrhosis in patients with chronic HBV infection with a high degree of accuracy, potentially decreasing the need for liver biopsy.

  6. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.

    PubMed

    Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu

    2017-08-28

    The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all p<0.05). Although alkaline phosphatase, total bilirubin and hemoglobin reached statistical significance (p=0.009, 0.027 and 0.012, respectively), all had very low average bias which ranged from 0.01% to 2%. Potassium, total hemoglobin and percent deoxyhemoglobin were statistically significant for the neonatal capillary tube study (p=0.011, 0.033 and 0.041, respectively) but no biases greater than ±4% were identified for these parameters. All observed differences of these 48 laboratory tests were not clinically significant. The modern PTS investigated in this study is acceptable for reliable sample delivery for routine chemistry, hematology, coagulation and blood gas (in syringe and capillary tube) laboratory tests.

  7. [Reversed clinicopathological conference (R-CPC)--interpreting laboratory data in the same way as physical findings].

    PubMed

    Sugano, Mitsutoshi; Shimada, Masashi; Moriyoshi, Miho; Kitagawa, Kiyoki; Nakashima, Hiromi; Wada, Hideo; Yanagihara, Katsunori; Fujisawa, Shinya; Yonekawa, Osamu; Honda, Takayuki

    2012-05-01

    Routine laboratory data are discussed by time series analysis in reversed clinicopathological conferences (R-CPC) at Shinshu University School of Medicine. We can identify fine changes in the laboratory data and the importance of negative data (without any changes) using time series analysis. Routine laboratory tests can be performed repeatedly and relatively cheaply, and time series analysis can be performed. The examination process of routine laboratory data in the R-CPC is almost the same as the process of taking physical findings. Firstly, general findings are checked and then the state of each organ is examined. Although routine laboratory data are cheap, we can obtain much more information about a patient's state than from physical examinations. In this R-CPC, several specialists in the various fields of laboratory medicine discussed the routine laboratory data of a patient, and we tried to understand the detailed state of the patient. R-CPC is an educational method to examine laboratory data and we, reconfirmed the usefulness of R-CPC to elucidate the clinical state of the patient.

  8. PCR identification of bacteria in blood culture does not fit the daily workflow of a routine microbiology laboratory.

    PubMed

    Karumaa, Santra; Kärpänoja, Pauliina; Sarkkinen, Hannu

    2012-03-01

    We have evaluated the GenoType blood culture assay (Hain Lifescience, Nehren, Germany) for the identification of bacteria in 233 positive blood cultures and assessed its suitability in the workflow of a routine microbiology laboratory. In 68/233 (29.2%) samples, the culture result could not be confirmed by the GenoType assay due to a lack of primers in the test, multiple organisms in the sample, or inconsistency with respect to the identification by culture. Although the GenoType blood culture assay gives satisfactory results for bacteria for which primers are available, there are difficulties in applying the test in the routine microbiology laboratory.

  9. K(3)EDTA Vacuum Tubes Validation for Routine Hematological Testing.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K(3)EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K(3)EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests.

  10. K3EDTA Vacuum Tubes Validation for Routine Hematological Testing

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Poli, Giovanni; Solero, Giovanni Pietro; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Background and Objective. Some in vitro diagnostic devices (e.g, blood collection vacuum tubes and syringes for blood analyses) are not validated before the quality laboratory managers decide to start using or to change the brand. Frequently, the laboratory or hospital managers select the vacuum tubes for blood collection based on cost considerations or on relevance of a brand. The aim of this study was to validate two dry K3EDTA vacuum tubes of different brands for routine hematological testing. Methods. Blood specimens from 100 volunteers in two different K3EDTA vacuum tubes were collected by a single, expert phlebotomist. The routine hematological testing was done on Advia 2120i hematology system. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.05. Results and Conclusions. Different brand's tubes evaluated can represent a clinically relevant source of variations only on mean platelet volume (MPV) and platelet distribution width (PDW). Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according to him/her technical or economical reasons for routine hematological tests. PMID:22888448

  11. Contamination of the Clinical Microbiology Laboratory with Vancomycin-Resistant Enterococci and Multidrug- Resistant Enterobacteriaceae: Implications for Hospital and Laboratory Workers

    PubMed Central

    Collins, Susan M.; Hacek, Donna M.; Degen, Lisa A.; Wright, Marc O.; Noskin, Gary A.; Peterson, Lance R.

    2001-01-01

    We surveyed environmental surfaces in our clinical microbiology laboratory to determine the prevalence of vancomycin-resistant enterococci (VRE) and multidrug-resistant Enterobacteriaceae (MDRE) during a routine working day. From a total of 193 surfaces, VRE were present on 20 (10%) and MDRE were present on 4 (2%) of the surfaces tested. In a subsequent survey after routine cleaning, all of the 24 prior positive surfaces were found to be negative. Thus, those in the laboratory should recognize that many surfaces may be contaminated by resistant organisms during routine processing of patient specimens. PMID:11574615

  12. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China.

    PubMed

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun; Wang, Zhiguo

    2015-01-01

    To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479/1307), 38% (228/598), and 36% (449/1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them.

  13. National survey on intra-laboratory turnaround time for some most common routine and stat laboratory analyses in 479 laboratories in China

    PubMed Central

    Fei, Yang; Zeng, Rong; Wang, Wei; He, Falin; Zhong, Kun

    2015-01-01

    Introduction To investigate the state of the art of intra-laboratory turnaround time (intra-TAT), provide suggestions and find out whether laboratories accredited by International Organization for Standardization (ISO) 15189 or College of American Pathologists (CAP) will show better performance on intra-TAT than non-accredited ones. Materials and methods 479 Chinese clinical laboratories participating in the external quality assessment programs of chemistry, blood gas, and haematology tests organized by the National Centre for Clinical Laboratories in China were included in our study. General information and the median of intra-TAT of routine and stat tests in last one week were asked in the questionnaires. Results The response rate of clinical biochemistry, blood gas, and haematology testing were 36% (479 / 1307), 38% (228 / 598), and 36% (449 / 1250), respectively. More than 50% of laboratories indicated that they had set up intra-TAT median goals and almost 60% of laboratories declared they had monitored intra-TAT generally for every analyte they performed. Among all analytes we investigated, the intra-TAT of haematology analytes was shorter than biochemistry while the intra-TAT of blood gas analytes was the shortest. There were significant differences between median intra-TAT on different days of the week for routine tests. However, there were no significant differences in median intra-TAT reported by accredited laboratories and non-accredited laboratories. Conclusions Many laboratories in China are aware of intra-TAT control and are making effort to reach the target. There is still space for improvement. Accredited laboratories have better status on intra-TAT monitoring and target setting than the non-accredited, but there are no significant differences in median intra-TAT reported by them. PMID:26110033

  14. Comparison of basic laboratory test results with more sophisticated laboratory and in-situ tests methods on soils in southeastern Wisconsin : final report, March 21, 2009.

    DOT National Transportation Integrated Search

    2009-03-21

    This study investigates all of the generated soils data in an attempt to use the more 'routine' laboratory tests to determine geotechnical design parameters (such as phiangle, cohesion, wet unit weight, unconfined compression, consolidation character...

  15. Most routine laboratory testing of pediatric psychiatric patients in the emergency department is not medically necessary.

    PubMed

    Donofrio, J Joelle; Horeczko, Timothy; Kaji, Amy; Santillanes, Genevieve; Claudius, Ilene

    2015-05-01

    We examined the patient characteristics and hospital charges associated with routine medical clearance laboratory screening tests in 1,082 children younger than age eighteen who were brought to the emergency department (ED) for involuntary mental health holds--that is, each patient was brought to the ED to be evaluated for being a danger to him- or herself or to others, for being gravely disabled (unable to meet his or her basic needs due to a mental disorder), or both--from July 2009 to December 2010. Testing was performed on 871 of the children; all patients also received a clinical examination. The median charge for blood and urine testing together was $1,235, and the most frequent ordering pattern was the full comprehensive panel of tests. Of the patients with a nonconcerning clinical examination, 94.3 percent also had clinically nonsignificant test results. When we extrapolated cost savings to the national level, omitting routine screening laboratory tests in the population of pediatric patients presenting to the ED on an involuntary psychiatric hold with nonconcerning clinical exams could represent up to $90 million in savings annually, without reducing the ability to screen for emergency medical conditions. Provider-initiated diagnostic testing instead of routine screening would lead to significantly lower charges to the ED and the patient. Project HOPE—The People-to-People Health Foundation, Inc.

  16. Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory.

    PubMed

    Mlinaric, Ana; Milos, Marija; Coen Herak, Désirée; Fucek, Mirjana; Rimac, Vladimira; Zadro, Renata; Rogic, Dunja

    2018-02-23

    The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared. Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers' software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented. Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated. Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.

  17. Clinical utility of routine laboratory testing to identify possible secondary causes in older men with osteoporosis: the Osteoporotic Fractures in Men (MrOS) Study

    PubMed Central

    Fink, Howard A.; Litwack-Harrison, Stephanie; Taylor, Brent C.; Bauer, Douglas C.; Orwoll, Eric S.; Lee, Christine G.; Barrett-Connor, Elizabeth; Schousboe, John T.; Kado, Deborah M.; Garimella, Pranav S.; Ensrud, Kristine E.

    2016-01-01

    Purpose To evaluate the utility of recommended laboratory testing to identify secondary causes in older men with osteoporosis, we examined prevalence of laboratory abnormalities in older men with and without osteoporosis. Methods 1572 men aged ≥65 years in the Osteoporotic Fractures in Men study completed bone mineral density (BMD) testing and a battery of laboratory measures, including serum calcium, phosphorus, alkaline phosphatase, parathyroid hormone (PTH), thyroid-stimulating hormone (TSH), 25-OH vitamin D, total testosterone, spot urine calcium/creatinine ratio, spot urine albumin-creatinine ratio, creatinine-derived estimate glomerular filtration rate, 24-hour urine calcium, and 24-hour urine free cortisol. Using cross-sectional analyses, we calculated prevalence ratios (PR) and 95% confidence intervals (CI) for the association of any and specific laboratory abnormalities with osteoporosis, and the number of men with osteoporosis needed to test to identify one additional laboratory abnormality compared to testing men without osteoporosis. Results Approximately 60% of men had ≥1 laboratory abnormality in both men with and without osteoporosis. Among individual tests, only vitamin D insufficiency (PR, 1.13; 95% CI, 1.05–1.22) and high alkaline phosphatase (PR, 3.05; 95% CI, 1.52–6.11) were more likely in men with osteoporosis. Hypercortisolism and hyperthyroidism were uncommon and not significantly more frequent in men with osteoporosis. No osteoporotic men had hypercalciuria. Conclusions Though most of these older men had ≥1 laboratory abnormality, few routinely recommended individual tests were more common in men with osteoporosis than in those without osteoporosis. Possibly excepting vitamin D and alkaline phosphatase, benefit of routine laboratory testing to identify possible secondary causes in older osteoporotic men appears low. Results may not be generalizable to younger men or to older men in whom history and exam findings raise clinical suspicion for a secondary cause of osteoporosis. PMID:26458388

  18. Comparison of microbiological diagnosis of urinary tract infection in young children by routine health service laboratories and a research laboratory: Diagnostic cohort study.

    PubMed

    Birnie, Kate; Hay, Alastair D; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O'Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C; Sterne, Jonathan A C

    2017-01-01

    To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the "index test"), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service laboratories should consider adopting procedures used in the research laboratory for paediatric urine samples. Primary care clinicians should try to obtain clean catch samples, even in very young children.

  19. Evaluation of Mycology Laboratory Proficiency Testing

    PubMed Central

    Reilly, Andrew A.; Salkin, Ira F.; McGinnis, Michael R.; Gromadzki, Sally; Pasarell, Lester; Kemna, Maggi; Higgins, Nancy; Salfinger, Max

    1999-01-01

    Changes over the last decade in overt proficiency testing (OPT) regulations have been ostensibly directed at improving laboratory performance on patient samples. However, the overt (unblinded) format of the tests and regulatory penalties associated with incorrect values allow and encourage laboratorians to take extra precautions with OPT analytes. As a result OPT may measure optimal laboratory performance instead of the intended target of typical performance attained during routine patient testing. This study addresses this issue by evaluating medical mycology OPT and comparing its fungal specimen identification error rates to those obtained in a covert (blinded) proficiency testing (CPT) program. Identifications from 188 laboratories participating in the New York State mycology OPT from 1982 to 1994 were compared with the identifications of the same fungi recovered from patient specimens in 1989 and 1994 as part of the routine procedures of 88 of these laboratories. The consistency in the identification of OPT specimens was sufficient to make accurate predictions of OPT error rates. However, while the error rates in OPT and CPT were similar for Candida albicans, significantly higher error rates were found in CPT for Candida tropicalis, Candida glabrata, and other common pathogenic fungi. These differences may, in part, be due to OPT’s use of ideal organism representatives cultured under optimum growth conditions. This difference, as well as the organism-dependent error rate differences, reflects the limitations of OPT as a means of assessing the quality of routine laboratory performance in medical mycology. PMID:10364601

  20. Doubling immunochemistry laboratory testing efficiency with the cobas e 801 module while maintaining consistency in analytical performance.

    PubMed

    Findeisen, P; Zahn, I; Fiedler, G M; Leichtle, A B; Wang, S; Soria, G; Johnson, P; Henzell, J; Hegel, J K; Bendavid, C; Collet, N; McGovern, M; Klopprogge, K

    2018-06-04

    The new immunochemistry cobas e 801 module (Roche Diagnostics) was developed to meet increasing demands on routine laboratories to further improve testing efficiency, while maintaining high quality and reliable data. During a non-interventional multicenter evaluation study, the overall performance, functionality and reliability of the new module was investigated under routine-like conditions. It was tested as a dedicated immunochemistry system at four sites and as a consolidator combined with clinical chemistry at three sites. We report on testing efficiency and analytical performance of the new module. Evaluation of sample workloads with site-specific routine request patterns demonstrated increased speed and almost doubled throughput (maximal 300 tests per h), thus revealing that one cobas e 801 module can replace two cobas e 602 modules while saving up to 44% floor space. Result stability was demonstrated by QC analysis per assay throughout the study. Precision testing over 21 days yielded excellent results within and between labs, and, method comparison performed versus the cobas e 602 module routine results showed high consistency of results for all assays under study. In a practicability assessment related to performance and handling, 99% of graded features met (44%) or even exceeded (55%) laboratory expectations, with enhanced reagent management and loading during operation being highlighted. By nearly doubling immunochemistry testing efficiency on the same footprint as a cobas e 602 module, the new module has a great potential to further consolidate and enhance laboratory testing while maintaining high quality analytical performance with Roche platforms. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. First external quality assurance program of the Italian HLA-B*57:01 Network assessing the performance of clinical virology laboratories in HLA-B*57:01 testing.

    PubMed

    Meini, Genny; Dello Russo, Cinzia; Allice, Tiziano; Barresi, Renata; D'Arrigo, Roberta; Falasca, Francesca; Lipsi, Maria Rosaria; Paolucci, Stefania; Zanussi, Stefania; Antonetti, Raffaele; Baldanti, Fausto; Basaglia, Giancarlo; Bruzzone, Bianca; Polilli, Ennio; Ghisetti, Valeria; Pucillo, Leopoldo Paolo; Turriziani, Ombretta; Pirazzoli, Antonella; Navarra, Pierluigi; Zazzi, Maurizio

    2016-05-01

    Since the HLA-B*57:01 allele is strongly associated with abacavir hypersensitivity reaction, testing for the presence of HLA-B*57:01 is mandatory before administration of abacavir. While HLA-B*57:01 testing is usually provided by pharmacogenetics, genetics or blood transfusion services, clinical virology laboratories can be an optimal opportunity for HLA-B*57:01 testing since they receive blood samples for routine HIV monitoring and have the expertise for convenient and less expensive PCR-based point mutation assays. The Italian HLA-B*57:01 Network gathers accredited clinical virology laboratories offering HLA-B*57:01 testing in Italy with the aim to share protocols, test new methods, develop and maintain external quality assurance (EQA) programs. A panel of 9HLA-B*57:01-positive and 16HLA-B*57:01-negative frozen blood samples were blindly distributed to 10 units including 9 clinical virology laboratories and one reference pharmacology laboratory. Each laboratory was free to use its own routine method for DNA extraction and HLA-B*57:01 testing. DNA was extracted by automated workstations in 6 units and by manual spin columns in 4. Eight units used the Duplicα Real Time HLA-B*57:01 kit by Euroclone and two units used two different PCR homemade protocols. All the 10 units correctly identified all the 25 samples. The first HLA-B*57:01 EQA program run in Italy showed that clinical virology units are equipped and proficient for providing HLA-B*57:01 testing by inexpensive assays easy to integrate into their routine. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Culturing Stool Specimens for Campylobacter spp., Pennsylvania, USA

    PubMed Central

    M’ikanatha, Nkuchia M.; Dettinger, Lisa A.; Perry, Amanda; Rogers, Paul; Reynolds, Stanley M.

    2012-01-01

    In 2010, we surveyed 176 clinical laboratories in Pennsylvania regarding stool specimen testing practices for enteropathogens, including Campylobacter spp. Most (96.3%) routinely test for Campylobacter spp. In 17 (15.7%), a stool antigen test is the sole method for diagnosis. We recommend that laboratory practice guidelines for Campylobacter spp. testing be developed. PMID:22377086

  3. Preanalytical management: serum vacuum tubes validation for routine clinical chemistry.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing. Blood specimens from 100 volunteers in five different serum vacuum tubes (Tube I: VACUETTE, Tube II: LABOR IMPORT, Tube III: S-Monovette, Tube IV: SST and Tube V: SST II) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas 6000 module. The significance of the differences between samples was assessed by paired Student's t-test after checking for normality. The level of statistical significance was set at P < 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation. Basically, our validation will permit the laboratory or hospital managers to select the brand's vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices.

  4. Preanalytical management: serum vacuum tubes validation for routine clinical chemistry

    PubMed Central

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2012-01-01

    Introduction The validation process is essential in accredited clinical laboratories. Aim of this study was to validate five kinds of serum vacuum tubes for routine clinical chemistry laboratory testing. Materials and methods: Blood specimens from 100 volunteers in five diff erent serum vacuum tubes (Tube I: VACUETTE®, Tube II: LABOR IMPORT®, Tube III: S-Monovette®, Tube IV: SST® and Tube V: SST II®) were collected by a single, expert phlebotomist. The routine clinical chemistry tests were analyzed on cobas® 6000 module. The significance of the diff erences between samples was assessed by paired Student’s t-test after checking for normality. The level of statistical significance was set at P < 0.005. Finally, the biases from Tube I, Tube II, Tube III, Tube IV and Tube V were compared with the current desirable quality specifications for bias (B), derived from biological variation. Results and conclusions: Basically, our validation will permit the laboratory or hospital managers to select the brand’s vacuum tubes validated according him/her technical or economical reasons, in order to perform the following laboratory tests: glucose, total cholesterol, high density lipoprotein-cholesterol, triglycerides, total protein, albumin, blood urea nitrogen, uric acid, alkaline phosphatise, aspartate aminotransferase, gamma-glutamyltransferase, lactate dehydrogenase, creatine kinase, total bilirubin, direct bilirubin, calcium, iron, sodium and potassium. On the contrary special attention will be required if the laboratory already performs creatinine, amylase, phosphate and magnesium determinations and the quality laboratory manager intend to change the serum tubes. We suggest that laboratory management should both standardize the procedures and frequently evaluate the quality of in vitro diagnostic devices. PMID:22838184

  5. Use of proficiency samples to assess diagnostic laboratories in France performing a Trichinella digestion assay.

    PubMed

    Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal

    2007-07-01

    Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.

  6. Testing the performance of microbiological safety cabinets used in microbiology laboratories in South Korea.

    PubMed

    Hwang, S H; Yi, T W; Cho, K H; Lee, I M; Yoon, C S

    2011-09-01

    To test a performance of the microbiological safety cabinets (MSCs) according to the type of MSCs in microbial laboratories. Tests were carried out to assess the performance of 31 MSCs in 14 different facilities, including six different biological test laboratories in six hospitals and eight different laboratories in three universities. The following tests were performed on the MSCs: the downflow test, intake velocity test, high-efficiency particulate air filter leak test and the airflow smoke pattern test. These performance tests were carried out in accordance with the standard procedures. Only 23% of Class II A1 (8), A2 (19) and unknown MSCs (4) passed these performance tests. The main reasons for the failure of MSCs were inappropriate intake velocity (65%), leakage in the HEPA filter sealing (50%), unbalanced airflow smoke pattern in the cabinets (39%) and inappropriate downflow (27%). This study showed that routine checks of MSCs are important to detect and strengthen the weak spots that frequently develop, as observed during the evaluation of the MSCs of various institutions. Routine evaluation and maintenance of MSCs are critical for optimizing performance. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  7. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  8. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  9. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  10. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  11. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  12. 10 CFR 26.169 - Reporting Results.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... request. The laboratory shall routinely provide quantitative values for confirmatory opiate test results... requested quantitative values for the test result. (3) For a specimen that has an adulterated or substituted... of the standard curve, the laboratory may report to the MRO that the quantitative value “exceeds the...

  13. A computer system for processing data from routine pulmonary function tests.

    PubMed Central

    Pack, A I; McCusker, R; Moran, F

    1977-01-01

    In larger pulmonary function laboratories there is a need for computerised techniques of data processing. A flexible computer system, which is used routinely, is described. The system processes data from a relatively large range of tests. Two types of output are produced--one for laboratory purposes, and one for return to the referring physician. The system adds an automatic interpretative report for each set of results. In developing the interpretative system it has been necessary to utilise a number of arbitrary definitions. The present terminology for reporting pulmonary function tests has limitations. The computer interpretation system affords the opportunity to take account of known interaction between measurements of function and different pathological states. Images PMID:329462

  14. The human false-negative rate of rescreening Pap tests. Measured in a two-arm prospective clinical trial.

    PubMed

    Renshaw, A A; Lezon, K M; Wilbur, D C

    2001-04-25

    Routine quality control rescreening often is used to calculate the false-negative rate (FNR) of gynecologic cytology. Theoretic analysis suggests that this is not appropriate, due to the high FNR of rescreening and the inability to actually measure it. The authors sought to determine the FNR of manual rescreening in a large, prospective, two-arm clinical trial using an analytic instrument in the evaluation. The results of the Autopap System Clinical Trial, encompassing 25,124 analyzed slides, were reviewed. The false-negative and false-positive rates at various thresholds were determined for routine primary screening, routine rescreening, Autopap primary screening, and Autopap rescreening by using a simple, standard methodology. The FNR of routine manual rescreening at the level of atypical squamous cells of undetermined significance (ASCUS) was 73%, more than 3 times the FNR of primary screening; 11 cases were detected. The FNR of Autopap rescreening was 34%; 80 cases were detected. Routine manual rescreening decreased the laboratory FNR by less than 1%; Autopap rescreening reduced the overall laboratory FNR by 5.7%. At the same time, the false-positive rate for Autopap screening was significantly less than that of routine manual screening at the ASCUS level (4.7% vs. 5.6%; P < 0.0001). Rescreening with the Autopap system remained more sensitive than manual rescreening at the low grade squamous intraepithelial lesions threshold (FNR of 58.8% vs. 100%, respectively), although the number of cases rescreened was low. Routine manual rescreening cannot be used to calculate the FNR of primary screening. Routine rescreening is an extremely ineffective method to detect error and thereby decrease a laboratory's FNR. The Autopap system is a much more effective way of detecting errors within a laboratory and reduces the laboratory's FNR by greater than 25%.

  15. Opportunities for improving the efficiency of paediatric HIV treatment programmes

    PubMed Central

    Revill, Paul A.; Walker, Simon; Mabugu, Travor; Nathoo, Kusum J.; Mugyenyi, Peter; Kekitinwa, Adeodata; Munderi, Paula; Bwakura-Dangarembizi, Mutsawashe; Musiime, Victor; Bakeera-Kitaka, Sabrina; Nahirya-Ntege, Patricia; Walker, A. Sarah; Sculpher, Mark J.; Gibb, Diana M.

    2015-01-01

    Objectives: To conduct two economic analyses addressing whether to: routinely monitor HIV-infected children on antiretroviral therapy (ART) clinically or with laboratory tests; continue or stop cotrimoxazole prophylaxis when children become stabilized on ART. Design and methods: The ARROW randomized trial investigated alternative strategies to deliver paediatric ART and cotrimoxazole prophylaxis in 1206 Ugandan/Zimbabwean children. Incremental cost-effectiveness and value of implementation analyses were undertaken. Scenario analyses investigated whether laboratory monitoring (CD4+ tests for efficacy monitoring; haematology/biochemistry for toxicity) could be tailored and targeted to be delivered cost-effectively. Cotrimoxazole use was examined in malaria-endemic and non-endemic settings. Results: Using all trial data, clinical monitoring delivered similar health outcomes to routine laboratory monitoring, but at a reduced cost, so was cost-effective. Continuing cotrimoxazole improved health outcomes at reduced costs. Restricting routine CD4+ monitoring to after 52 weeks following ART initiation and removing toxicity testing was associated with an incremental cost-effectiveness ratio of $6084 per quality-adjusted life-year (QALY) across all age groups, but was much lower for older children (12+ years at initiation; incremental cost-effectiveness ratio = $769/QALY). Committing resources to improve cotrimoxazole implementation appears cost-effective. A healthcare system that could pay $600/QALY should be willing to spend up to $12.0 per patient-year to ensure continued provision of cotrimoxazole. Conclusion: Clinically driven monitoring of ART is cost-effective in most circumstances. Routine laboratory monitoring is generally not cost-effective at current prices, except possibly CD4+ testing amongst adolescents initiating ART. Committing resources to ensure continued provision of cotrimoxazole in health facilities is more likely to represent an efficient use of resources. PMID:25396263

  16. A Case of Human Infection by Rickettsia slovaca in Greece.

    PubMed

    Kostopoulou, Vasiliki; Chochlakis, Dimosthenis; Kanta, Chrysoula; Katsanou, Andromachi; Rossiou, Konstantina; Rammos, Aidonis; Papadopoulos, Spyridon-Filippos; Katsarou, Theodora; Tselentis, Yannis; Psaroulaki, Anna; Boukas, Chrysostomos

    2016-07-22

    Although tick-borne rickettsiosis is endemic in Greece, until recently, human samples arriving at the National Reference Centre under suspicion of rickettsial infection were routinely tested only for Rickettsia typhi and R. conorii. However, identification of additional rickettsia species in ticks prompted revision of the protocol in 2010. Until that year, all human samples received by the laboratory were tested for antibodies against R. conorii and R. typhi only. Now, tests for R. slovaca, R. felis, and R. mongolotimonae are all included in routine analysis. The current description of a human R. slovaca case is possible as a result of these changes in routine testing.

  17. Rabies direct fluorescent antibody test does not inactivate rabies or eastern equine encephalitis viruses.

    PubMed

    Jarvis, Jodie A; Franke, Mary A; Davis, April D

    2016-08-01

    An examination using the routine rabies direct fluorescent antibody test was performed on rabies or Eastern equine encephalitis positive mammalian brain tissue to assess inactivation of the virus. Neither virus was inactivated with acetone fixation nor the routine test, thus laboratory employees should treat all samples as rabies and when appropriate Eastern equine encephalitis positive throughout the whole procedure. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Occupational Survey Report, Cardiopulmonary Laboratory, AFSC 4H0X1, OSSN: 2541

    DTIC Science & Technology

    2004-02-01

    patients within facility 97 E0211 Set up humidifiers 97 E0175 Instruct patients in use of incentive spirometers 97 A0031 Obtain sputum samples 97 A0026...D0137 Calibrate pulmonary function testing equipment 100 D0150 Perform routine spirometry tests 100 D0146 Perform lung diffusion tests 100 A0042 Perform...consultations, or procedures 31 D0150 Perform routine spirometry tests 23 35 TABLE A2 REPRESENTATIVE TASKS PERFORMED BY MEMBERS IN THE SUPERVISION AND

  19. Laboratory testing in management of patients with suspected Ebolavirus disease: infection control and safety.

    PubMed

    Gilbert, G L

    2015-08-01

    If routine laboratory safety precautions are followed, the risk of laboratory-acquired infection from handling specimens from patients with Ebolavirus disease (EVD) is very low, especially in the early 'dry' stage of disease. In Australia, border screening to identify travellers returning from EVD-affected west African countries during the 2014-2015 outbreak has made it unlikely that specimens from patients with unrecognised EVD would be sent to a routine diagnostic laboratory. Australian public health and diagnostic laboratories associated with hospitals designated for the care of patients with EVD have developed stringent safety precautions for EVD diagnostic and other tests likely to be required for supportive care of the sickest (and most infectious) patients with EVD, including as wide a range of point-of-care tests as possible. However, it is important that the stringent requirements for packaging, transport and testing of specimens that might contain Ebolavirus--which is a tier 1 security sensitive biology agent--do not delay the diagnosis and appropriate management of other potentially serious but treatable infectious diseases, which are far more likely causes of a febrile illness in people returning from west Africa. If necessary, urgent haematology, biochemistry and microbiological tests can be performed safely, whilst awaiting the results of EVD tests, in a PC-2 laboratory with appropriate precautions including: use of recommended personal protective equipment (PPE) for laboratory staff; handling any unsealed specimens in a class 1 or II biosafety cabinet; using only centrifuges with sealed rotors; and safe disposal or decontamination of all used equipment and laboratory waste.

  20. Quality Indicators for the Total Testing Process.

    PubMed

    Plebani, Mario; Sciacovelli, Laura; Aita, Ada

    2017-03-01

    ISO 15189:2012 requires the use of quality indicators (QIs) to monitor and evaluate all steps of the total testing process, but several difficulties dissuade laboratories from effective and continuous use of QIs in routine practice. An International Federation of Clinical Chemistry and Laboratory Medicine working group addressed this problem and implemented a project to develop a model of QIs to be used in clinical laboratories worldwide to monitor and evaluate all steps of the total testing process, and decrease error rates and improve patient services in laboratory testing. All laboratories are invited, at no cost, to enroll in the project and contribute to harmonized management at the international level. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Drugs in the Workplace: Legal Developments.

    ERIC Educational Resources Information Center

    Scholick, Gary P.

    1989-01-01

    An update on legal aspects of drug testing in the workplace looks at pre-employment screening, reasonable suspicion testing, routine testing in periodic physical examinations, random testing, and unionized employers. Practical guidelines are given for minimizing obtrusiveness, confirmatory tests, laboratory selection, notification of policy,…

  2. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  3. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  4. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  5. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  6. 42 CFR 493.941 - Hematology (including routine hematology and coagulation).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of a laboratory's responses for qualitative and quantitative hematology tests or analytes, the...) of this section. (2) For quantitative hematology tests or analytes, the program must determine the...

  7. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania.

    PubMed

    Coyle, Catelyn; Kwakwa, Helena

    2016-01-01

    Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012-August 31, 2013) and after (September 1, 2013-May 31, 2014) implementation of the dual-routine HCV/HIV testing model. A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care.

  8. Dual-Routine HCV/HIV Testing: Seroprevalence and Linkage to Care in Four Community Health Centers in Philadelphia, Pennsylvania

    PubMed Central

    Kwakwa, Helena

    2016-01-01

    Objective Despite common risk factors, screening for hepatitis C virus (HCV) and HIV at the same time as part of routine medical care (dual-routine HCV/HIV testing) is not commonly implemented in the United States. This study examined improvements in feasibility of implementation, screening increase, and linkage to care when a dual-routine HCV/HIV testing model was integrated into routine primary care. Methods National Nursing Centers Consortium implemented a dual-routine HCV/HIV testing model at four community health centers in Philadelphia, Pennsylvania, on September 1, 2013. Routine HCV and opt-out HIV testing replaced the routine HCV and opt-in HIV testing model through medical assistant-led, laboratory-based testing and electronic medical record modification to prompt, track, report, and facilitate reimbursement for tests performed on uninsured individuals. This study examined testing, seropositivity, and linkage-to-care comparison data for the nine months before (December 1, 2012–August 31, 2013) and after (September 1, 2013–May 31, 2014) implementation of the dual-routine HCV/HIV testing model. Results A total of 1,526 HCV and 1,731 HIV tests were performed before, and 1,888 HCV and 3,890 HIV tests were performed after dual-routine testing implementation, resulting in a 23.7% increase in HCV tests and a 124.7% increase in HIV tests. A total of 70 currently HCV-infected and four new HIV-seropositive patients vs. 101 HCV-infected and 13 new HIV-seropositive patients were identified during these two periods, representing increases of 44.3% for HCV antibody-positive and RNA-positive tests and 225.0% for HIV-positive tests. Linkage to care increased from 27 currently infected HCV--positive and one HIV-positive patient pre-dual-routine testing to 39 HCV--positive and nine HIV-positive patients post-dual-routine testing. Conclusion The dual-routine HCV/HIV testing model shows that integrating dual-routine testing in a primary care setting is possible and leads to increased HCV and HIV screening, enhanced seropositivity diagnosis, and improved linkage to care. PMID:26862229

  9. Cost Effectiveness Analysis of Clinically Driven versus Routine Laboratory Monitoring of Antiretroviral Therapy in Uganda and Zimbabwe

    PubMed Central

    Medina Lara, Antonieta; Kigozi, Jesse; Amurwon, Jovita; Muchabaiwa, Lazarus; Nyanzi Wakaholi, Barbara; Mujica Mota, Ruben E.; Walker, A. Sarah; Kasirye, Ronnie; Ssali, Francis; Reid, Andrew; Grosskurth, Heiner; Babiker, Abdel G.; Kityo, Cissy; Katabira, Elly; Munderi, Paula; Mugyenyi, Peter; Hakim, James; Darbyshire, Janet; Gibb, Diana M.; Gilks, Charles F.

    2012-01-01

    Background Despite funding constraints for treatment programmes in Africa, the costs and economic consequences of routine laboratory monitoring for efficacy and toxicity of antiretroviral therapy (ART) have rarely been evaluated. Methods Cost-effectiveness analysis was conducted in the DART trial (ISRCTN13968779). Adults in Uganda/Zimbabwe starting ART were randomised to clinically-driven monitoring (CDM) or laboratory and clinical monitoring (LCM); individual patient data on healthcare resource utilisation and outcomes were valued with primary economic costs and utilities. Total costs of first/second-line ART, routine 12-weekly CD4 and biochemistry/haematology tests, additional diagnostic investigations, clinic visits, concomitant medications and hospitalisations were considered from the public healthcare sector perspective. A Markov model was used to extrapolate costs and benefits 20 years beyond the trial. Results 3316 (1660LCM;1656CDM) symptomatic, immunosuppressed ART-naive adults (median (IQR) age 37 (32,42); CD4 86 (31,139) cells/mm3) were followed for median 4.9 years. LCM had a mean 0.112 year (41 days) survival benefit at an additional mean cost of $765 [95%CI:685,845], translating into an adjusted incremental cost of $7386 [3277,dominated] per life-year gained and $7793 [4442,39179] per quality-adjusted life year gained. Routine toxicity tests were prominent cost-drivers and had no benefit. With 12-weekly CD4 monitoring from year 2 on ART, low-cost second-line ART, but without toxicity monitoring, CD4 test costs need to fall below $3.78 to become cost-effective (<3xper-capita GDP, following WHO benchmarks). CD4 monitoring at current costs as undertaken in DART was not cost-effective in the long-term. Conclusions There is no rationale for routine toxicity monitoring, which did not affect outcomes and was costly. Even though beneficial, there is little justification for routine 12-weekly CD4 monitoring of ART at current test costs in low-income African countries. CD4 monitoring, restricted to the second year on ART onwards, could be cost-effective with lower cost second-line therapy and development of a cheaper, ideally point-of-care, CD4 test. PMID:22545079

  10. High-Value, Cost-Conscious Care: Iterative Systems-Based Interventions to Reduce Unnecessary Laboratory Testing.

    PubMed

    Sadowski, Brett W; Lane, Alison B; Wood, Shannon M; Robinson, Sara L; Kim, Chin Hee

    2017-09-01

    Inappropriate testing contributes to soaring healthcare costs within the United States, and teaching hospitals are vulnerable to providing care largely for academic development. Via its "Choosing Wisely" campaign, the American Board of Internal Medicine recommends avoiding repetitive testing for stable inpatients. We designed systems-based interventions to reduce laboratory orders for patients admitted to the wards at an academic facility. We identified the computer-based order entry system as an appropriate target for sustainable intervention. The admission order set had allowed multiple routine tests to be ordered repetitively each day. Our iterative study included interventions on the automated order set and cost displays at order entry. The primary outcome was number of routine tests controlled for inpatient days compared with the preceding year. Secondary outcomes included cost savings, delays in care, and adverse events. Data were collected over a 2-month period following interventions in sequential years and compared with the year prior. The first intervention led to 0.97 fewer laboratory tests per inpatient day (19.4%). The second intervention led to sustained reduction, although by less of a margin than order set modifications alone (15.3%). When extrapolating the results utilizing fees from the Centers for Medicare and Medicaid Services, there was a cost savings of $290,000 over 2 years. Qualitative survey data did not suggest an increase in care delays or near-miss events. This series of interventions targeting unnecessary testing demonstrated a sustained reduction in the number of routine tests ordered, without adverse effects on clinical care. Published by Elsevier Inc.

  11. [The usefulness of routine laboratory tests in the evaluation of sudden threat of pregnant woman and fetus in pre-eclampsia].

    PubMed

    Malarewicz, Andrzej; Gruszka, Olga; Szymkiewicz, Jadwiga; Rogala, Jerzy

    2006-04-01

    The fact that the progress of pre-eclampsia is highly unpredictable is the reason to run necessary monitoring, among others, by means of laboratory tests. Their aim is to determine explicitly if the pregnancy can be continued and terminated naturally or should be terminated by pre-term induced delivery or Caesarean section. There is a wide range of laboratory investigations recommended in pregnancy complicated by pre-eclampsia. The results reported in the literature though are controversial and inexplicit. The purpose of the research was to verify routine lab tests results used in decision making for emergency termination of pregnancy as a result of increased threatening clinical symptoms and to evaluate their usefulness in decision making to start delivery. The investigation covered 152 women who were divided into three groups. One consisted of 62 pregnant women with light form of pre-eclampsia, the other of 24 pregnant women with severe form of pre-eclampsia. The control group consisted of 66 healthy pregnant women. All pregnant women with pre-eclampsia diagnosed delivered by Caesarean section. The decision to perform the operation was based on biophysical findings of the fetus. At the moment of decision-making, blood was drawn for laboratory testing of the following parameters: systemic blood, coagulation parameters, total protein and protein fractios, non-protein nitrogen blood components, glucose, electrolytes, indicating enzymes and excretory enzymes of protein metabolism, lipid fractions. Routine lab tests performed in pre-eclampsia do not indicate distinct abnormalities the moment fetus life threatening clinical symptoms occur that enforce the decision of immediate delivery, the exception are the indicating enzymes. Acute clinical symptoms that endanger fetus life in pre-eclampsia correlate with distinct activity of AspAT, AIAT and LDH. Laboratory tests are of no prognostic value in the prediction of sudden worsening of the fetus condition in pre-eclampsia.

  12. Standardization of Laboratory Methods for the PERCH Study

    PubMed Central

    Karron, Ruth A.; Morpeth, Susan C.; Bhat, Niranjan; Levine, Orin S.; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Knoll, Maria Deloria; Kotloff, Karen L.; Madhi, Shabir A.; Scott, J. Anthony G.; Thea, Donald M.; Adrian, Peter V.; Ahmed, Dilruba; Alam, Muntasir; Anderson, Trevor P.; Antonio, Martin; Baillie, Vicky L.; Dione, Michel; Endtz, Hubert P.; Gitahi, Caroline; Karani, Angela; Kwenda, Geoffrey; Maiga, Abdoul Aziz; McClellan, Jessica; Mitchell, Joanne L.; Morailane, Palesa; Mugo, Daisy; Mwaba, John; Mwansa, James; Mwarumba, Salim; Nyongesa, Sammy; Panchalingam, Sandra; Rahman, Mustafizur; Sawatwong, Pongpun; Tamboura, Boubou; Toure, Aliou; Whistler, Toni; O’Brien, Katherine L.; Murdoch, David R.

    2017-01-01

    Abstract The Pneumonia Etiology Research for Child Health study was conducted across 7 diverse research sites and relied on standardized clinical and laboratory methods for the accurate and meaningful interpretation of pneumonia etiology data. Blood, respiratory specimens, and urine were collected from children aged 1–59 months hospitalized with severe or very severe pneumonia and community controls of the same age without severe pneumonia and were tested with an extensive array of laboratory diagnostic tests. A standardized testing algorithm and standard operating procedures were applied across all study sites. Site laboratories received uniform training, equipment, and reagents for core testing methods. Standardization was further assured by routine teleconferences, in-person meetings, site monitoring visits, and internal and external quality assurance testing. Targeted confirmatory testing and testing by specialized assays were done at a central reference laboratory. PMID:28575358

  13. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    PubMed

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  14. Antinuclear antibody determination in a routine laboratory.

    PubMed Central

    Feltkamp, T E

    1996-01-01

    Pitfalls in the method for demonstrating antinuclear antibodies (ANA) by the indirect immunofluorescence technique are described and the use of international standard preparations outlined. Determination of the optimal border dilution dividing positive from negative results is discussed. Each laboratory is a unique setting; it must define its own method, which should rarely be changed. One should not rely on copying methods from other laboratories or commercial firms, but the reproducibility of the nuclear substrate, the conjugate, and other variables should be controlled daily by the use of a control serum which has been related to the WHO standard preparation for ANA of the homogeneous type. Since many sera contain mixtures of different ANA, the results of routine tests are best expressed in titres or expressions of the intensity of fluorescence. The ANA test using the immunofluorescence technique should be used as a screening method for other tests allowing a more defined interpretation of the ANA. Each laboratory should individually determine the border between positive and negative results. Therefore about 200 sera from local healthy controls equally distributed over sex and age, and 100 sera from local patients with definite SLE should be tested. Since the local clinicians should become acquainted with this border it should rarely be changed. Finally each laboratory should participate regularly in national and international quality control rounds, where sera known to be difficult to interpret are tested. The judgment of the organisers of these rounds should stimulate improvements in the participating laboratories. PMID:8984936

  15. [Responses to customer complaints at commercial laboratories].

    PubMed

    Honma, M

    1997-10-01

    For commercial laboratories, one of the routine duties involves responding to various kinds of inquiries and complaints received from customers. As causes of complaints, lack of communication between the laboratory and customer, and test errors were considered. In this paper, complaints received by our laboratory were collected and classified by content, and measures to prevent test error are reported. We think the complaints contain important information that can be used to improve the quality of our laboratory. We hope that reinforcement of communication with customers and promoting test knowledge among the customers can produce more clearly worded complaints which will provide more valuable information. We try to receive and deal with these complaints seriously.

  16. Utility of laboratory studies in seizures of children older than one month of age.

    PubMed

    Karbasi, S Akhavan; Mosadegh, M Modares; Fallah, R

    2009-08-01

    Seizure is the most common paediatric neurological disease which occurs in ten percent of children. In approaching a convulsive patient, finding the causes of seizure is essential, and the patient's history as well as the physical examination are important. The role of routine laboratory tests for children's seizures (except neonates) is undetermined, but checking for serum sodium, glucose, calcium and urea routinely has been advised. The purpose of this study was to determine the diagnostic efficacy of these serum chemistry tests in the seizures of children older than one month of age. In this descriptive, retrospective study, medical records of 302 hospitalised children with seizure were reviewed. Results of laboratory tests, like sodium, calcium, blood glucose and urea levels, pertinent history and physical examination, and the change in patient management based on serum chemistry test results, were analysed. All the children in the study were classified as having seizure with or without fever. In 302 hospitalised children with seizure, about ten percent of 938 tests were abnormal. 27.7 percent of these abnormal results were seen in 1-12-month-old infants. Only 11 percent of abnormal tests (1.3 percent of total tests) might have caused a seizure. Also, 0.2 percent of the results could not be predicted from the history or physical examination, which was conducted in patients younger than one year of age. Routine determination of serum chemistry values in seizures of children does not contribute to therapy, and are costly and time-consuming. It may not be helpful and informative unless the patient is less than one year of age.

  17. Feasibility Study of HIV Sentinel Surveillance using PMTCT data in Cameroon: from Scientific Success to Programmatic Failure.

    PubMed

    Billong, Serge C; Dee, Jacob; Fokam, Joseph; Nguefack-Tsague, Georges; Ekali, Gabriel L; Fodjo, Raoul; Temgoua, Edith S; Billong, Edson-Joan; Sosso, Samuel M; Mosoko, Jembia J; Monebenimp, Francisca; Ndjolo, Alexis; Bissek, Anne-Cecile Z-K; Bolu, Omotayo; Elat, Jean-Bosco N

    2017-01-03

    In low-income countries (LICs), HIV sentinel surveillance surveys (HIV-SSS) are recommended in between two demographic and health surveys, due to low-cost than the latter. Using the classical unlinked anonymous testing (UAT), HIV-SSS among pregnant women raised certain ethical and financial challenges. We therefore aimed at evaluating how to use prevention of mother-to-child transmission of HIV (PMTCT) routine data as an alternative approach for HIV-SSS in LICs. A survey conducted through 2012 among first antenatal-care attendees (ANC1) in the ten regions of Cameroon. HIV testing was performed at PMTCT clinics as-per the national serial algorithm (rapid test), and PMTCT site laboratory (PMTCT-SL) performances were evaluated by comparison with results of the national reference laboratory (NRL), determined as the reference standard. Acceptance rate for HIV testing was 99%, for a total of 6521 ANC1 (49 · 3% aged 15-24) enrolled nationwide. Among 6103 eligible ANC1, sensitivity (using NRL testing as the reference standard) was 81 · 2%, ranging from 58 · 8% (South region) to 100% (West region); thus implying that 18 · 8% HIV-infected ANC1 declared HIV-negative at the PMTCT-SL were positive from NRL-results. Specificity was 99 · 3%, without significant disparity across sites. At population-level, this implies that every year in Cameroon, ~2,500 HIV-infected women are wrongly declared seronegative, while ~1,000 are wrongly declared seropositive. Only 44 · 4% (16/36) of evaluated laboratories reached the quality target of 80%. The study identified weaknesses in routine PMTCT HIV testing. As Cameroon transitions to using routine PMTCT data for HIV-SSS among pregnant women, there is need in optimizing quality system to ensure robust routine HIV testing for programmatic and surveillance purposes.

  18. Evaluation of selected clinical and diagnostic parameters in girls with anorexia nervosa (I).

    PubMed

    Nogal, Paweł; Pniewska-Siark, Barbara; Lewiński, Andrzej

    2008-08-01

    Body weight loss in patients with anorexia nervosa (AN) is accompanied by a number of hormonal and metabolic disorders. The scope and intensity of these disorders may have a considerable influence on the prognosis in this disease. The goal of the study was an evaluation of selected diagnostic examinations in comparison with clinical data of female patients with AN. Retrospective studies involved eighty-seven (87) patients with AN. On therapy commencement, routine laboratory tests (full blood cell count, serum concentrations of sodium, potassium, glucose, cholesterol, triglycerides, total calcium, phosphates, total protein and the urea) and hormonal tests (TSH, TSH, FT4, FT3, E2, T, cortisol measured at 8(00), 17(00) and 24(00), LH and FSH in stimulation test with GnRH) were performed in each patient. Correlations were determined between clinical data and the measured hormone concentrations. In the studied girls, the mean values of routine laboratory tests, performed at the beginning of the therapy, were within the normal ranges (except hypernatremia). The mean concentrations of LH, FSH and FT4 were below reference values; the mean concentration of cortisol considerably exceeded the standard range. Statistically significant relations were demonstrated between BMI values and the concentrations of LH, E2 and cortisol. Body weigh loss is not significantly reflected by abnormal results of routinely performed laboratory tests. Hypogonadotropic hypogonadism and hypercortisolemia are the most characteristic hormonal symptoms in girls with AN.

  19. Comparison of microbiological diagnosis of urinary tract infection in young children by routine health service laboratories and a research laboratory: Diagnostic cohort study

    PubMed Central

    Birnie, Kate; Hay, Alastair D.; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O’Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C.; Sterne, Jonathan A. C.

    2017-01-01

    Objectives To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. Population and methods We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the “index test”), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. Results 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. Conclusions The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service laboratories should consider adopting procedures used in the research laboratory for paediatric urine samples. Primary care clinicians should try to obtain clean catch samples, even in very young children. PMID:28199403

  20. Validation of a single-platform method for hematopoietic CD34+ stem cells enumeration according to accreditation procedure.

    PubMed

    Massin, Frédéric; Huili, Cai; Decot, Véronique; Stoltz, Jean-François; Bensoussan, Danièle; Latger-Cannard, Véronique

    2015-01-01

    Stem cells for autologous and allogenic transplantation are obtained from several sources including bone marrow, peripheral blood or cord blood. Accurate enumeration of viable CD34+ hematopoietic stem cells (HSC) is routinely used in clinical settings, especially to monitor progenitor cell mobilization and apheresis. The number of viable CD34+ HSC has also been shown to be the most critical factor in haematopoietic engraftment. The International Society for Cellular Therapy actually recommends the use of single-platform flow cytometry system using 7-AAD as a viability dye. In a way to move routine analysis from a BD FACSCaliburTM instrument to a BD FACSCantoTM II, according to ISO 15189 standard guidelines, we define laboratory performance data of the BDTM Stem Cell Enumeration (SCE) kit on a CE-IVD system including a BD FACSCanto II flow cytometer and the BD FACSCantoTM Clinical Software. InterQCTM software, a real time internet laboratory QC management system developed by VitroTM and distributed by Becton DickinsonTM, was also tested to monitor daily QC data, to define the internal laboratory statistics and to compare them to external laboratories. Precision was evaluated with BDTM Stem Cell Control (high and low) results and the InterQC software, an internet laboratory QC management system by Vitro. This last one drew Levey-Jennings curves and generated numeral statistical parameters allowing detection of potential changes in the system performances as well as interlaboratory comparisons. Repeatability, linearity and lower limits of detection were obtained with routine samples from different origins. Agreement evaluation between BD FACSCanto II system versus BD FACSCalibur system was tested on fresh peripheral blood, freeze-thawed apheresis, fresh bone marrow and fresh cord blood samples. Instrument's measure and staining repeatability clearly evidenced acceptable variability on the different samples tested. Intra- and inter-laboratory CV in CD34+ cell absolute count are consistent and reproducible. Linearity analysis, established between 2 and 329 cells/μl showed a linear relation between expected counts and measured counts (R2=0.97). Linear regression and Bland-Altman representations showed an excellent correlation on samples from different sources between the two systems and allowed the transfer of routine analysis from BD FACSCalibur to BD FACSCanto II. The BD SCE kit provides an accurate measure of the CD34 HSC, and can be used in daily routine to optimize the enumeration of hematopoietic CD34+ stem cells by flow cytometry. Moreover, the InterQC system seems to be a very useful tool for laboratory daily quality monitoring and thus for accreditation.

  1. Clinical routine utility of basophil activation testing for diagnosis of hymenoptera-allergic patients with emphasis on individuals with negative venom-specific IgE antibodies.

    PubMed

    Korošec, Peter; Šilar, Mira; Eržen, Renato; Čelesnik, Nina; Bajrović, Nissera; Zidarn, Mihaela; Košnik, Mitja

    2013-01-01

    Previous reports suggest the usefulness of basophil activation testing (BAT) in Hymenoptera-allergic patients with negative venom-specific IgE antibodies. We sought to evaluate the diagnostic utility of this testing in a routine clinical laboratory setting. Twenty-one patients with anaphylactic reactions to Hymenoptera sting (median grade III) and negative venom-specific IgE were routinely and prospectively tested with BAT. We were able to diagnose 81% (17 of 21) of patients with BAT and 57% (12 of 21) with intradermal skin testing. Three wasp venom-allergic patients showed IgE positivity to rVes v 5. Four patients (19%) were negative for all tests. In the case of double-positive BAT, the culprit insect correlated with the venom that induced a significantly higher basophil response. BAT allows the identification of severe Hymenoptera-allergic patients with negative specific IgE and skin tests. The routine use of this cellular test should facilitate prescription of venom immunotherapy in complex cases with inconclusive diagnostic results. Copyright © 2013 S. Karger AG, Basel.

  2. Interlaboratory ring trial to evaluate CFT proficiency of European laboratories for diagnosis of glanders in equids.

    PubMed

    Laroucau, K; Colaneri, C; Jaÿ, M; Corde, Y; Drapeau, A; Durand, B; Zientara, S; Beck, C

    2016-06-18

    To evaluate the routine complement fixation test (CFT) used to detect Burkholderia mallei antibodies in equine sera, an interlaboratory proficiency test was held with 24 European laboratories, including 22 National Reference Laboratories for glanders. The panels sent to participants were composed of sera with or without B mallei antibodies. This study confirmed the reliability of CFT and highlighted its intralaboratory reproducibility. However, the sensitivity of glanders serodiagnosis and laboratory proficiency may be improved by standardising critical reagents, including antigens, and by developing a standard B mallei serum. British Veterinary Association.

  3. Development of the Global Measles Laboratory Network.

    PubMed

    Featherstone, David; Brown, David; Sanders, Ray

    2003-05-15

    The routine reporting of suspected measles cases and laboratory testing of samples from these cases is the backbone of measles surveillance. The Global Measles Laboratory Network (GMLN) has developed standards for laboratory confirmation of measles and provides training resources for staff of network laboratories, reference materials and expertise for the development and quality control of testing procedures, and accurate information for the Measles Mortality Reduction and Regional Elimination Initiative. The GMLN was developed along the lines of the successful Global Polio Laboratory Network, and much of the polio laboratory infrastructure was utilized for measles. The GMLN has developed as countries focus on measles control activities following successful eradication of polio. Currently more than 100 laboratories are part of the global network and follow standardized testing and reporting procedures. A comprehensive laboratory accreditation process will be introduced in 2002 with six quality assurance and performance indicators.

  4. New generation mix-designs : laboratory testing and construction of the APT test sections.

    DOT National Transportation Integrated Search

    2010-03-01

    Recent changes to the Texas HMA mix-design procedures such as adaption of the higher PG asphalt-binder grades and the Hamburg test have ensured that the mixes routinely used on the Texas highways are not prone to rutting. However, performance concern...

  5. [Unnecessary routine laboratory tests in patients referred for surgical services].

    PubMed

    Mata-Miranda, María del Pilar; Cano-Matus, Norberto; Rodriguez-Murrieta, Margarita; Guarneros-Zapata, Idalia; Ortiz, Mario

    2016-01-01

    To question the usefulness of the lab analysis considered routine testing for the identification of abnormalities in the surgical care. To determine the percentage of unnecessary laboratory tests in the preoperative assessment as well as to estimate the unnecessary expenses. A descriptive, cross-sectional study of patients referred for surgical evaluation between January 1st and March 31st 2013. The database of laboratory testing and electronic files were reviewed. Reference criteria from surgical services were compared with the tests requested by the family doctor. In 65% of the patients (n=175) unnecessary examinations were requested, 25% (n=68) were not requested the tests that they required, and only 10% of the patients were requested laboratory tests in accordance with the reference criteria (n=27). The estimated cost in unnecessary examinations was $1,129,552 in a year. The results were similar to others related to this theme, however, they had not been revised from the perspective of the first level of attention regarding the importance of adherence to the reference criteria which could prevent major expenditures. It is a priority for leaders and operational consultants in medical units to establish strategies and lines of action that ensure compliance with institutional policies so as to contain spending on comprehensive services, and which in turn can improve the medical care. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  6. [Antimicrobial resistance testing in clinical practice].

    PubMed

    Doi, Yohei

    2012-02-01

    Previously unrecognized or underrecognized antimicrobial resistant bacteria, including NDM-1-producing Enterobacteriaceae and multidrug-resistant Acinetobacter baumannii, were recently identified in health care facilities in Japan. Vigilance in the clinical microbiology laboratory for these organisms is the key to early recognition of their emergence. Many of these organisms can be confirmed or at least suspected through routine susceptibility testing, which can then be referred to reference laboratories for further phenotypic or genetic testing. Antimicrobial resistance testing plays a crucial role in patient management, infection control and monitoring of local as well as national and international epidemiology.

  7. Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    PubMed

    Amukele, Timothy K; Sokoll, Lori J; Pepper, Daniel; Howard, Dana P; Street, Jeff

    2015-01-01

    Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.

  8. Validation of pharmaceutical potency determinations by quantitative nuclear magnetic resonance spectrometry.

    PubMed

    Webster, Gregory K; Marsden, Ian; Pommerening, Cynthia A; Tyrakowski, Christina M

    2010-05-01

    With the changing development paradigms in the pharmaceutical industry, laboratories are challenged to release materials for clinical studies with rapid turnaround times. To minimize cost demands, many businesses are looking to develop ways of using early Good Manufacturing Practice (GMP) materials of active pharmaceutical ingredients (API) for Good Laboratory Practice (GLP) toxicology studies. To make this happen, the analytical laboratory releases the material by one of three scenarios: (1) holding the GLP release until full GMP testing is ready, (2) issuing a separate lot number for a portion of the GMP material and releasing the material for GLP use, or (3) releasing the lot of material for GLP using alternate (equivalent) method(s) not specified for GMP release testing. Many companies are finding the third scenario to be advantageous in terms of cost and efficiency through the use of quantitative nuclear magnetic resonance (q-NMR). The use of q-NMR has proved to be a single-point replacement for routine early development testing that previously combined elements of identity testing, chromatographic assay, moisture analysis, residual solvent analysis, and elemental analysis. This study highlights that q-NMR can be validated to meet current regulatory analytical method guidelines for routine pharmaceutical analysis.

  9. Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology.

    PubMed

    Rossen, J W A; Friedrich, A W; Moran-Gilad, J

    2018-04-01

    Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. To review the practical aspects of implementing bacterial whole genome sequencing (WGS) in routine diagnostic laboratories. Review of the literature and expert opinion. In this review, we discuss when and how to integrate whole genome sequencing (WGS) in the routine workflow of the clinical laboratory. In addition, as the microbiology laboratories have to adhere to various national and international regulations and criteria for their accreditation, we deliberate on quality control issues for using WGS in microbiology, including the importance of proficiency testing. Furthermore, the current and future place of this technology in the diagnostic hierarchy of microbiology is described as well as the necessity of maintaining backwards compatibility with already established methods. Finally, we speculate on the question of whether WGS can entirely replace routine microbiology in the future and the tension between the fact that most sequencers are designed to process multiple samples in parallel whereas for optimal diagnosis a one-by-one processing of the samples is preferred. Special reference is made to the cost and turnaround time of WGS in diagnostic laboratories. Further development is required to improve the workflow for WGS, in particular to shorten the turnaround time, reduce costs, and streamline downstream data analyses. Only when these processes reach maturity will reliance on WGS for routine patient management and infection control management become feasible, enabling the transformation of clinical microbiology into a genome-based and personalized diagnostic field. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  10. Laboratory Assays in Evaluation of Lynch Syndrome in Patients with Endometrial Carcinoma.

    PubMed

    Djordjevic, Bojana; Broaddus, Russell R

    2016-06-01

    This article reviews the main tissue testing modalities for Lynch Syndrome in the pathology laboratory, such as immunohistochemistry and PCR based analyses, and discusses their routine application, interpretation pitfalls, and troubleshooting of common technical performance issues. Discrepancies between laboratory and genetic testing may arise, and are examined in the context of the complexity of molecular abnormalities associated with Lynch Syndrome. The merits of targeted versus universal screening in a changing healthcare climate are addressed. In the absence of comprehensive screening programs, specific tumor topography and histological features that may prompt pathologist-initiated molecular tumor testing are outlined. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Laboratory Evaluation of the Alere q Point-of-Care System for Early Infant HIV Diagnosis.

    PubMed

    Hsiao, Nei-yuan; Dunning, Lorna; Kroon, Max; Myer, Landon

    2016-01-01

    Early infant diagnosis (EID) and prompt linkage to care are critical to minimise the high morbidity and mortality associated with infant HIV infection. Attrition in the "EID cascade" is common; however, point-of-care (POC) EID assays with same-day result could facilitate prompt linkage of HIV-infected infant to treatment. Despite a number of POC EID assays in development, few have been independently evaluated and data on new technologies are urgently needed to inform policy. We compared Alere q 1/2 Detect POC system laboratory test characteristics with the local standard of care (SOC), Roche CAP/CTM HIV-1 qualitative PCR in an independent laboratory-based evaluation in Cape Town, South Africa. Routinely EID samples collected between November 2013 and September 2014 were each tested by both SOC and POC systems. Repeat testing was done to troubleshoot any discrepancy between POC and SOC results. Overall, 1098 children with a median age of 47 days (IQR, 42-117) were included. Birth PCR (age <7 days) comprised of 8% (n = 92) tests while 56% (n = 620) of children tested as part of routine EID (ages 6-14 weeks). In the overall direct comparison, Alere q Detect achieved sensitivity of 95.5% (95% CI, 91.7-97.9%) and a specificity of 99.8% (95% CI, 99.1-100%). Following repeat testing of discordant samples and exclusion of any inconclusive results, the POC assay sensitivity and specificity were 96.9% (95% CI 93.4-98.9%) and 100% (lower 95% CI 98%) respectively. Among birth PCR tests the POC assay had slightly lower sensitivity (93.3% vs 96.5% in routine EID) and higher assay error rate (10% vs 5% in samples of older children, p = 0.04). Our results indicate this POC assay performs well for EID in the laboratory. The high specificity and thus high positive predictive value would suggest a positive POC result may be adequate for immediate infant ART initiation. While POC testing for EID may have particular utility for birth testing at delivery facilities, the lower sensitivity and error rate requires further attention, as does field implementation of POC EID technologies in other clinical care settings.

  12. How is the high vaginal swab used to investigate vaginal discharge in primary care and how do GPs' expectations of the test match the tests performed by their microbiology services?

    PubMed

    Noble, H; Estcourt, C; Ison, C; Goold, P; Tite, L; Carter, Y H

    2004-06-01

    To describe the management of vaginal discharge in general practice, with particular regard to the use of the high vaginal swab (HVS), and to compare GPs' expectations of this test with the processing and reporting undertaken by different laboratories. A postal questionnaire survey of 2146 GPs in the North Thames area and postal questionnaire study of the 22 laboratories serving the same GPs were carried out. GPs were asked how they would manage a young woman with vaginal discharge and what information they would like on an HVS report. Laboratories were asked how they would process and report on the HVS sample from the same patient. Response rate was 26%. 72% of GPs would take an HVS and 62% would refer on to a genitourinary medicine (GUM) clinic. 45% would offer empirical therapy and 47% of these would treat for candida initially. 75% of GPs routinely request "M,C&S" on HVS samples but 55% only want to be informed about specific pathogens. Routine processing of HVS samples varies widely between laboratories and 86% only report specific pathogens. 78% of GPs would like to be offered a suggested diagnosis on HVS reports, and 74% would like a suggested treatment. 43% of laboratories ever provide a diagnosis, and 14% provide a suggested treatment. GPs frequently manage vaginal discharge and most of them utilise the HVS. GPs' expectations of the test are not well matched to laboratory processing or reporting of the samples.

  13. How to isolate, identify and determine antimicrobial susceptibility of anaerobic bacteria in routine laboratories?

    PubMed

    Nagy, E; Boyanova, L; Justesen, U S

    2018-02-17

    There has been increased interest in the study of anaerobic bacteria that cause human infection during the past decade. Many new genera and species have been described using 16S rRNA gene sequencing of clinical isolates obtained from different infection sites with commercially available special culture media to support the growth of anaerobes. Several systems, such as anaerobic pouches, boxes, jars and chambers provide suitable anaerobic culture conditions to isolate even strict anaerobic bacteria successfully from clinical specimens. Beside the classical, time-consuming identification methods and automated biochemical tests, the use of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has revolutionized identification of even unusual and slow-growing anaerobes directly from culture plates, providing the possibility of providing timely information about anaerobic infections. The aim of this review article is to present methods for routine laboratories, which carry out anaerobic diagnostics on different levels. Relevant data from the literature mostly published during the last 7 years are encompassed and discussed. The review involves topics on the anaerobes that are members of the commensal microbiota and their role causing infection, the key requirements for collection and transport of specimens, processing of specimens in the laboratory, incubation techniques, identification and antimicrobial susceptibility testing of anaerobic bacteria. Advantages, drawbacks and specific benefits of the methods are highlighted. The present review aims to update and improve anaerobic microbiology in laboratories with optimal conditions as well as encourage its routine implementation in laboratories with restricted resources. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Use of laboratory testing for genital chlamydial infection in Norway.

    PubMed Central

    Aavitsland, P

    1993-01-01

    OBJECTIVE--To assess the use of laboratory tests for genital chlamydial infection in Norway. DESIGN--Questionnaire survey of general practitioners' practice in chlamydial testing, retrospective survey of laboratory records, 1986-91, and prospective study of testing in one laboratory during four weeks. SETTING--All 18 microbiological laboratories in Norway (4.2 million population), including one serving all doctors in Vestfold county (0.2 million population). SUBJECTS--302 general practitioners. MAIN MEASURES--GPs' routine practice, methods used for testing, 1986-91, and sex specific and age group specific testing in 1991. RESULTS--201(69%) GPs replied to the questionnaire: 101(51%) would test all women younger than 25 years at routine pelvic examination, 107(54%) all girls at first pelvic examination, 131(66%) all pregnant women, and 106(54%) all men whose female partner had urogenital complaints. Nationwide in 1986, 122,000 tests were performed (2.9 per 100 population); 10% were positive and 51% were cell culture tests. In 1991, 341,000 tests were performed (8.0 per 100 population); 4.5% were positive and 15% were cell culture tests. 13,184 tests were performed in Vestfold in 1991 (6.6 per 100 population). The age group specific rates (per 100 population) among women were: age 15-19 years, 22.0(95% confidence interval 18.2 to 25.8); 20-24 years, 47.2(42.1 to 52.3); 25-29 years, 42.3(37.1 to 47.5); 30-34 years, 29.8(25.4 to 34.2); and 35-39 years, 12.5(9.5 to 15.5). CONCLUSIONS--GPs use liberal indications for testing. The dramatic increase in testing, especially by enzyme immunoassays, in populations with a low prevalence of infection results in low cost effectiveness and low predictive value of positive tests, which in women over 29 years is estimated as 17-36%. IMPLICATIONS--Doctors should be educated about the limitations of enzyme immunoassays in screening low prevalence populations, and laboratories should apply a confirmatory test to specimens testing positive with such assays. PMID:10131639

  15. Evaluation of the NanoCHIP® Gastrointestinal Panel (GIP) Test for Simultaneous Detection of Parasitic and Bacterial Enteric Pathogens in Fecal Specimens

    PubMed Central

    Ken Dror, Shifra; Pavlotzky, Elsa; Barak, Mira

    2016-01-01

    Infectious gastroenteritis is a global health problem associated with high morbidity and mortality rates. Rapid and accurate diagnosis is crucial to allow appropriate and timely treatment. Current laboratory stool testing has a long turnaround time (TAT) and demands highly qualified personnel and multiple techniques. The need for high throughput and the number of possible enteric pathogens compels the implementation of a molecular approach which uses multiplex technology, without compromising performance requirements. In this work we evaluated the feasibility of the NanoCHIP® Gastrointestinal Panel (GIP) (Savyon Diagnostics, Ashdod, IL), a molecular microarray-based screening test, to be used in the routine workflow of our laboratory, a big outpatient microbiology laboratory. The NanoCHIP® GIP test provides simultaneous detection of nine major enteric bacteria and parasites: Campylobacter spp., Salmonella spp., Shigella spp., Giardia sp., Cryptosporidium spp., Entamoeba histolytica, Entamoeba dispar, Dientamoeba fragilis, and Blastocystis spp. The required high-throughput was obtained by the NanoCHIP® detection system together with the MagNA Pure 96 DNA purification system (Roche Diagnostics Ltd., Switzerland). This combined system has demonstrated a higher sensitivity and detection yield compared to the conventional methods in both, retrospective and prospective samples. The identification of multiple parasites and bacteria in a single test also enabled increased efficiency of detecting mixed infections, as well as reduced hands-on time and work load. In conclusion, the combination of these two automated systems is a proper response to the laboratory needs in terms of improving laboratory workflow, turn-around-time, minimizing human errors and can be efficiently integrated in the routine work of the laboratory. PMID:27447173

  16. Laboratory Surge Response to Pandemic (H1N1) 2009 Outbreak, New York City Metropolitan Area, USA

    PubMed Central

    Crawford, James M.; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D.; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M.

    2010-01-01

    The North Shore–Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments. PMID:20031036

  17. Laboratory surge response to pandemic (H1N1) 2009 outbreak, New York City metropolitan area, USA.

    PubMed

    Crawford, James M; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M; Ginocchio, Christine C

    2010-01-01

    The North Shore-Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments.

  18. Efficiency in pathology laboratories: a survey of operations management in NHS bacteriology.

    PubMed

    Szczepura, A K

    1991-01-01

    In recent years pathology laboratory services in the U.K. have experienced large increases in demand. But the extent to which U.K. laboratories have introduced controls to limit unnecessary procedures within the laboratory was previously unclear. This paper presents the results of a survey of all 343 NHS bacteriology laboratories which records the extent to which such operations management controls are now in place. The survey shows large differences between laboratories. Quality controls over inputs, the use of screening tests as a culture substitute, the use of direct susceptibility testing, controls over routine antibiotic susceptibility testing, and controls over reporting of results all vary widely. The survey also records the prevalence of hospital antibiotic policies, the extent to which laboratories produce antibiograms for user clinicians, the degree of computerisation in data handling, and the degree of automation in processing specimens. Finally, the survey uncovers a large variation between NHS labs in the percentage of bacteriology samples which prove positive and lead to antibiotic susceptibility tests being carried out.

  19. Taking a new biomarker into routine use – A perspective from the routine clinical biochemistry laboratory

    PubMed Central

    Sturgeon, Catharine; Hill, Robert; Hortin, Glen L; Thompson, Douglas

    2010-01-01

    There is increasing pressure to provide cost-effective healthcare based on “best practice.” Consequently, new biomarkers are only likely to be introduced into routine clinical biochemistry departments if they are supported by a strong evidence base and if the results will improve patient management and outcome. This requires convincing evidence of the benefits of introducing the new test, ideally reflected in fewer hospital admissions, fewer additional investigations and/or fewer clinic visits. Carefully designed audit and cost-benefit studies in relevant patient groups must demonstrate that introducing the biomarker delivers an improved and more effective clinical pathway. From the laboratory perspective, pre-analytical requirements must be thoroughly investigated at an early stage. Good stability of the biomarker in relevant physiological matrices is essential to avoid the need for special processing. Absence of specific timing requirements for sampling and knowledge of the effect of medications that might be used to treat the patients in whom the biomarker will be measured is also highly desirable. Analytically, automation is essential in modern high-throughput clinical laboratories. Assays must therefore be robust, fulfilling standard requirements for linearity on dilution, precision and reproducibility, both within- and between-run. Provision of measurements by a limited number of specialized reference laboratories may be most appropriate, especially when a new biomarker is first introduced into routine practice. PMID:21137030

  20. The CGE-PLATO Electronic Laboratory Instructional Programs. (August 1, 1972 Through June 30, 1975).

    ERIC Educational Resources Information Center

    Neal, J. P.

    Twelve PLATO lessons are reproduced in this document to show the status of computer guided experimentation (CGE) instructional programs. The lesson topics include a description of the CGE-PLATO instructional laboratory, an introduction to CGE-PLATO tests and special software routines, router lesson for two electrical engineering courses, and an…

  1. Usefulness of routine preoperative testing in a developing country: a prospective study

    PubMed Central

    Bordes, Julien; Cungi, Pierre-Julien; Savoie, Pierre-Henry; Bonnet, Stéphane; Kaiser, Eric

    2015-01-01

    Introduction The assessment of anesthetic risks is an essential component of preoperative evaluation. In developing world, preanesthesia evaluation may be challenging because patient's medical history and records are scare, and language barrier limits physical examination. Our objective was to evaluate the impact of routine preoperative testing in a low-resources setting. Methods Prospective observational study performed in a French forward surgical unit in Abidjan, Ivory Coast. 201 patients who were scheduled for non urgent surgery were screened with routine laboratory exams during preoperative evaluation. Changes in surgery were assessed (delayed or scheduled). Results Abnormal hemoglobin findings were reported in 35% of patients, abnormal WBC count in 11,1% of patients, abnormal platelets in 15,3% of patients. Positive HIV results were found in 8,3% of cases. Routine tests represented 43,6% of changes causes. Conclusion Our study showed that in a developing country, routine preoperative tests showed abnormal results up to 35% of cases, and represented 43,5% of delayed surgery causes. The rate of tests leading to management changes varied widely, from 0% to 8,3%. These results suggested that selected tests would be useful to diagnose diseases that required treatment before non urgent surgery. However, larger studies are needeed to evaluate the cost/benefit ratio and the clinical impact of such a strategy. PMID:26516395

  2. Comparative costs of the Mouse Inoculation Test (MIT) and Virus Isolation in Cell Culture (VICC) for use in rabies diagnosis in Brazil.

    PubMed

    Bones, Vanessa C; Gameiro, Augusto H; Castilho, Juliana G; Molento, Carla F M

    2015-05-01

    The decision to use laboratory animals rather than in vitro methods is frequently based on the financial costs involved, so the objective of our study was to compare the costs of performing the Mouse Inoculation Test (MIT) and Virus Isolation in Cell Culture (VICC) for use in rabies diagnosis in Brazil. Based on observations of laboratory routines at the Pasteur Institute, São Paulo, we listed the fixed cost (FC) and variable cost (VC) items necessary to perform both tests. Considering that 200 MITs are equivalent to 350 VICC assays, in terms of facilities and staff-hours needed per month, we calculated, for both tests, the average total cost per sample, the costs of the implementation of the laboratory structure, and the costs of routine use. With regard to absolute values, the total cost was mainly influenced by FC items, as they represented 60% of the cost for the MIT and 86% of the cost for VICC. A sample analysed by the MIT costs around 205% more than one analysed by using VICC. The MIT costs 74% and 406% more than VICC, when implementation costs and routine use per month, respectively, are taken into account. Our results can assist in the resolution of costing disputes that could hinder the replacement of animals for rabies diagnosis in Brazil. The method demonstrated here might also be useful for cost comparisons in other situations where animal use still continues when validated alternatives exist. 2015 FRAME.

  3. GC-C-IRMS in routine doping control practice: 3 years of drug testing data, quality control and evolution of the method.

    PubMed

    Polet, Michael; Van Eenoo, Peter

    2015-06-01

    In order to detect the misuse of endogenous anabolic steroids, doping control laboratories require methods that allow differentiation between endogenous steroids and their synthetic copies. Gas chromatography combustion isotope ratio mass spectrometry (GC-C-IRMS) is capable of measuring the carbon isotope ratio of urinary steroids and this allows differentiation between both. GC-C-IRMS and its application to doping control has evolved a lot during the last decade and so have the World Anti-Doping Agency (WADA) technical documents that describe how GC-C-IRMS should be applied. Especially the WADA technical document of 2014 introduced a number of obligatory quality controls and a fixed methodology that should be used by all the doping control laboratories. This document imposed more uniform methods between the laboratories in order to decrease the interlaboratory standard deviation and acquire similar results for the analysis of the same urine samples. In this paper, 3 years of drug testing data of our GC-C-IRMS method in routine doping control practice is described, with an emphasis on the new WADA technical document and its implementation. Useful data for other doping control laboratories is presented focussing on general method setup, quality control and data collected from routine samples. The paper concentrates on how IRMS results shift or remain similar by switching to the 2014 WADA technical document and gives insight in a straightforward approach to calculate the measurement uncertainty.

  4. Reasons for testing women for genital Chlamydia trachomatis infection in the Calgary region

    PubMed Central

    Church, Deirdre L; Zentner, Ali; Semeniuk, Heather; Henderson, Elizabeth; Read, Ron

    2003-01-01

    OBJECTIVE: To determine the clinical reason(s) for screening women with varying degrees of risk for genital Chlamydia trachomatis (CT) in the Calgary region. DESIGN: Women aged 15 to 75 years were enrolled at various patient care locations. Pertinent risk factors for genital CT infection were recorded and a gynecological examination was performed. Two endocervical swabs and a first-void urine sample were collected for CT detection using two different nucleic acid amplification test methods. SETTING: Calgary is an urban region that provides healthcare services to a population of almost one million people. Microbiology services are provided by Calgary Laboratory Services through a centralized regional laboratory service. MAIN RESULTS: 504 women with a mean age of 28.1 ±SD 8.22 years were enrolled. Two hundred ninety-one women (57.8%) were at high risk for acquiring genital CT infection. Twenty-eight (5.6%) tested positive for CT infection and almost all of these women (26 of 28, 93%) had risk factors for acquiring infection. Of the high-risk women, 9.8% were CT positive versus only 1.3% of women at low risk (P=0.0001). Only two of 152 (1.3%) women older than 30 years had genital CT infections. Although most women were asymptomatic, those with laboratory-confirmed CT infection were more likely to have genitourinary symptoms. Three hundred forty-three of 476 (72%) women who did not have genital CT infection had no risk factors, and screening was done as part of a routine gynecological examination for other purposes (prenatal visit, Pap smear). CONCLUSION: Women without risk factors are being screened routinely for genital CT infection as part of a routine gynecological examination done for other reasons. Elimination of the routine screening of low-risk women older than 30 years of age would decrease the current regional utilization of CT tests by as much as one-third. PMID:18159423

  5. Detection of BRAF V600 Mutations in Melanoma: Evaluation of Concordance between the Cobas® 4800 BRAF V600 Mutation Test and the Methods Used in French National Cancer Institute (INCa) Platforms in a Real-Life Setting

    PubMed Central

    Mourah, Samia; Denis, Marc G.; Narducci, Fabienne Escande; Solassol, Jérôme; Merlin, Jean-Louis; Sabourin, Jean-Christophe; Scoazec, Jean-Yves; Ouafik, L’Houcine; Emile, Jean-François; Heller, Remy; Souvignet, Claude; Bergougnoux, Loïc; Merlio, Jean-Philippe

    2015-01-01

    Vemurafenib is approved for the treatment of metastatic melanoma in patients with BRAF V600 mutation. In pivotal clinical trials, BRAF testing has always been done with the approved cobas 4800 BRAF test. In routine practice, several methods are available and are used according to the laboratories usual procedures. A national, multicenter, non-interventional study was conducted with prospective and consecutive collection of tumor samples. A parallel evaluation was performed in routine practice between the cobas 4800 BRAF V600 mutation test and home brew methods (HBMs) of 12 national laboratories, labelled and funded by the French National Cancer Institute (INCa). For 420 melanoma samples tested, the cobas method versus HBM showed a high concordance (93.3%; kappa = 0.86) in BRAF V600 genotyping with similar mutation rates (34.0% versus 35.7%, respectively). Overall, 97.4% and 98.6% of samples gave valid results using the cobas and HBM, respectively. Of the 185 samples strictly fulfilling the cobas guidelines, the concordance rate was even higher (95.7%; kappa = 0.91; 95%CI [0.85; 0.97]). Out of the 420 samples tested, 28 (6.7%) showed discordance between HBM and cobas. This prospective study shows a high concordance rate between the cobas 4800 BRAF V600 test and home brew methods in the routine detection of BRAF V600E mutations. PMID:25789737

  6. Results of external quality-assurance program for the National Atmospheric Deposition Program and National Trends Network during 1985

    USGS Publications Warehouse

    Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.

    1988-01-01

    External quality assurance monitoring of the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN) was performed by the U.S. Geological Survey during 1985. The monitoring consisted of three primary programs: (1) an intersite comparison program designed to assess the precision and accuracy of onsite pH and specific conductance measurements made by NADP and NTN site operators; (2) a blind audit sample program designed to assess the effect of routine field handling on the precision and bias of NADP and NTN wet deposition data; and (3) an interlaboratory comparison program designed to compare analytical data from the laboratory processing NADP and NTN samples with data produced by other laboratories routinely analyzing wet deposition samples and to provide estimates of individual laboratory precision. An average of 94% of the site operators participated in the four voluntary intersite comparisons during 1985. A larger percentage of participating site operators met the accuracy goal for specific conductance measurements (average, 87%) than for pH measurements (average, 67%). Overall precision was dependent on the actual specific conductance of the test solution and independent of the pH of the test solution. Data for the blind audit sample program indicated slight positive biases resulting from routine field handling for all analytes except specific conductance. These biases were not large enough to be significant for most data users. Data for the blind audit sample program also indicated that decreases in hydrogen ion concentration were accompanied by decreases in specific conductance. Precision estimates derived from the blind audit sample program indicate that the major source of uncertainty in wet deposition data is the routine field handling that each wet deposition sample receives. Results of the interlaboratory comparison program were similar to results of previous years ' evaluations, indicating that the participating laboratories produced comparable data when they analyzed identical wet deposition samples, and that the laboratory processing NADP and NTN samples achieved the best analyte precision of the participating laboratories. (Author 's abstract)

  7. Aglycosuric Diabetes

    PubMed Central

    Spaulding, W. B.; Spitzer, W. O.; Truscott, P. W.

    1963-01-01

    The usefulness of urine tests for glucose was compared with that of blood sugar determinations in detecting diabetes mellitus in 2000 medical outpatients. Eighty-five patients proved to be diabetic, but 33 of these had no glycosuria on their first visit and would not have been detected by laboratory tests had the blood glucose levels not been measured. Exactly one-half of the new diabetics discovered would have been missed (15 of 30) had only urine tests been performed. The new diabetics who were aglycosuric at their initial examination had a mild form of the disease, were predominantly elderly, and were controlled, in nearly every case, by diet alone. Most of these patients had evidence of an elevated renal threshold for glucose. These results indicate that there is a large group of patients with mild, asymptomatic, diabetes mellitus who remain undetected unless blood tests are employed routinely. Because they have little or no glycosuria these patients do not have polydipsia, polyphagia, polyuria, or loss of weight. Automation in the medical laboratory has made routine blood tests for glucose feasible and rewarding in detecting diabetes mellitus. PMID:20327667

  8. OFF-SITE ENVIRONMENTAL MONITORING REPORT: RADIATION MONITORING AROUND UNITED STATES NUCLEAR TEST AREAS, CALENDAR YEAR 1984

    EPA Science Inventory

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...

  9. OFFSITE ENVIRONMENTAL MONITORING REPORT. RADIATION MONITORING AROUND UNITED STATES NUCLEAR TEST AREAS, CALENDAR YEAR 1983

    EPA Science Inventory

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...

  10. OFF-SITE ENVIRONMENTAL MONITORING REPORT: RADIATION MONITORING AROUND UNITED STATES NUCLEAR TEST AREAS, CALENDAR YEAR 1987

    EPA Science Inventory

    This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...

  11. Enhancement of hepatitis virus immunoassay outcome predictions in imbalanced routine pathology data by data balancing and feature selection before the application of support vector machines.

    PubMed

    Richardson, Alice M; Lidbury, Brett A

    2017-08-14

    Data mining techniques such as support vector machines (SVMs) have been successfully used to predict outcomes for complex problems, including for human health. Much health data is imbalanced, with many more controls than positive cases. The impact of three balancing methods and one feature selection method is explored, to assess the ability of SVMs to classify imbalanced diagnostic pathology data associated with the laboratory diagnosis of hepatitis B (HBV) and hepatitis C (HCV) infections. Random forests (RFs) for predictor variable selection, and data reshaping to overcome a large imbalance of negative to positive test results in relation to HBV and HCV immunoassay results, are examined. The methodology is illustrated using data from ACT Pathology (Canberra, Australia), consisting of laboratory test records from 18,625 individuals who underwent hepatitis virus testing over the decade from 1997 to 2007. Overall, the prediction of HCV test results by immunoassay was more accurate than for HBV immunoassay results associated with identical routine pathology predictor variable data. HBV and HCV negative results were vastly in excess of positive results, so three approaches to handling the negative/positive data imbalance were compared. Generating datasets by the Synthetic Minority Oversampling Technique (SMOTE) resulted in significantly more accurate prediction than single downsizing or multiple downsizing (MDS) of the dataset. For downsized data sets, applying a RF for predictor variable selection had a small effect on the performance, which varied depending on the virus. For SMOTE, a RF had a negative effect on performance. An analysis of variance of the performance across settings supports these findings. Finally, age and assay results for alanine aminotransferase (ALT), sodium for HBV and urea for HCV were found to have a significant impact upon laboratory diagnosis of HBV or HCV infection using an optimised SVM model. Laboratories looking to include machine learning via SVM as part of their decision support need to be aware that the balancing method, predictor variable selection and the virus type interact to affect the laboratory diagnosis of hepatitis virus infection with routine pathology laboratory variables in different ways depending on which combination is being studied. This awareness should lead to careful use of existing machine learning methods, thus improving the quality of laboratory diagnosis.

  12. Clinical Laboratories – Production Factories or Specialized Diagnostic Centers

    PubMed Central

    Tóth, Judit

    2016-01-01

    Since a large proportion of medical decisions are based on laboratory results, clinical laboratories should meet the increasing demand of clinicians and their patients. Huge central laboratories may process over 10 million tests annually; they act as production factories, measuring emergency and routine tests with sufficient speed and accuracy. At the same time, they also serve as specialized diagnostic centers where well-trained experts analyze and interpret special test results. It is essential to improve and constantly monitor this complex laboratory service, by several methods. Sample transport by pneumatic tube system, use of an advanced laboratory information system and point-of-care testing may result in decreased total turnaround time. The optimization of test ordering may result in a faster and more cost-effective laboratory service. Autovalidation can save time for laboratory specialists, when the analysis of more complex results requires their attention. Small teams of experts responsible for special diagnostic work, and their interpretative reporting according to predetermined principles, may help to minimize subjectivity of these special reports. Although laboratory investigations have become so diversely developed in the past decades, it is essential that the laboratory can provide accurate results relatively quickly, and that laboratory specialists can support the diagnosis and monitoring of patients by adequate interpretation of esoteric laboratory methods. PMID:27683528

  13. Review of Pre-Analytical Errors in Oral Glucose Tolerance Testing in a Tertiary Care Hospital.

    PubMed

    Nanda, Rachita; Patel, Suprava; Sahoo, Sibashish; Mohapatra, Eli

    2018-03-13

    The pre-pre-analytical and pre-analytical phases form a major chunk of the errors in a laboratory. The process has taken into consideration a very common procedure which is the oral glucose tolerance test to identify the pre-pre-analytical errors. Quality indicators provide evidence of quality, support accountability and help in the decision making of laboratory personnel. The aim of this research is to evaluate pre-analytical performance of the oral glucose tolerance test procedure. An observational study that was conducted overa period of three months, in the phlebotomy and accessioning unit of our laboratory using questionnaire that examined the pre-pre-analytical errors through a scoring system. The pre-analytical phase was analyzed for each sample collected as per seven quality indicators. About 25% of the population gave wrong answer with regard to the question that tested the knowledge of patient preparation. The appropriateness of test result QI-1 had the most error. Although QI-5 for sample collection had a low error rate, it is a very important indicator as any wrongly collected sample can alter the test result. Evaluating the pre-analytical and pre-pre-analytical phase is essential and must be conducted routinely on a yearly basis to identify errors and take corrective action and to facilitate their gradual introduction into routine practice.

  14. Pitfalls in lung cancer molecular pathology: how to limit them in routine practice?

    PubMed

    Ilie, M; Hofman, P

    2012-01-01

    New treatment options in advanced non-small cell lung carcinoma (NSCLC) targeting activating epidermal growth factor receptor (EGFR) gene mutations and other genetic alterations demonstrated the clinical significance of the molecular features of specific subsets of tumors. Therefore, the development of personalized medicine has stimulated the routine integration into pathology departments of somatic mutation testing. However, clinical mutation testing must be optimized and standardized with regard to histological profile, type of samples, pre-analytical steps, methodology and result reporting. Routine molecular testing in NSCLC is currently moving beyond EGFR mutational analysis. Recent progress of targeted therapies will require molecular testing for a wide panel of mutations for a personalized molecular diagnosis. As a consequence, efficient testing of multiple molecular abnormalities is an urgent requirement in thoracic oncology. Moreover, increasingly limited tumor sample becomes a major challenge for molecular pathology. Continuous efforts should be made for safe, effective and specific molecular analyses. This must be based on close collaboration between the departments involved in the management of lung cancer. In this review we explored the practical issues and pitfalls surrounding the routine implementation of molecular testing in NSCLC in a pathology laboratory.

  15. miRNA assays in the clinical laboratory: workflow, detection technologies and automation aspects.

    PubMed

    Kappel, Andreas; Keller, Andreas

    2017-05-01

    microRNAs (miRNAs) are short non-coding RNA molecules that regulate gene expression in eukaryotes. Their differential abundance is indicative or even causative for a variety of pathological processes including cancer or cardiovascular disorders. Due to their important biological function, miRNAs represent a promising class of novel biomarkers that may be used to diagnose life-threatening diseases, and to monitor disease progression. Further, they may guide treatment selection or dosage of drugs. miRNAs from blood or derived fractions are particularly interesting candidates for routine laboratory applications, as they can be measured in most clinical laboratories already today. This assures a good accessibility of respective tests. Albeit their great potential, miRNA-based diagnostic tests have not made their way yet into the clinical routine, and hence no standardized workflows have been established to measure miRNAs for patients' benefit. In this review we summarize the detection technologies and workflow options that exist to measure miRNAs, and we describe the advantages and disadvantages of each of these options. Moreover, we also provide a perspective on data analysis aspects that are vital for translation of raw data into actionable diagnostic test results.

  16. Establishing a Timeline to Discontinue Routine Testing of Asymptomatic Pregnant Women for Zika Virus Infection - American Samoa, 2016-2017.

    PubMed

    Hancock, W Thane; Soeters, Heidi M; Hills, Susan L; Link-Gelles, Ruth; Evans, Mary E; Daley, W Randolph; Piercefield, Emily; Anesi, Magele Scott; Mataia, Mary Aseta; Uso, Anaise M; Sili, Benjamin; Tufa, Aifili John; Solaita, Jacqueline; Irvin-Barnwell, Elizabeth; Meaney-Delman, Dana; Wilken, Jason; Weidle, Paul; Toews, Karrie-Ann E; Walker, William; Talboy, Phillip M; Gallo, William K; Krishna, Nevin; Laws, Rebecca L; Reynolds, Megan R; Koneru, Alaya; Gould, Carolyn V

    2017-03-24

    The first patients with laboratory-confirmed cases of Zika virus disease in American Samoa had symptom onset in January 2016 (1). In response, the American Samoa Department of Health (ASDoH) implemented mosquito control measures (1), strategies to protect pregnant women (1), syndromic surveillance based on electronic health record (EHR) reports (1), Zika virus testing of persons with one or more signs or symptoms of Zika virus disease (fever, rash, arthralgia, or conjunctivitis) (1-3), and routine testing of all asymptomatic pregnant women in accordance with CDC guidance (2,3) . All collected blood and urine specimens were shipped to the Hawaii Department of Health Laboratory for Zika virus testing and to CDC for confirmatory testing. Early in the response, collection and testing of specimens from pregnant women was prioritized over the collection from symptomatic nonpregnant patients because of limited testing and shipping capacity. The weekly numbers of suspected Zika virus disease cases declined from an average of six per week in January-February 2016 to one per week in May 2016. By August, the EHR-based syndromic surveillance (1) indicated a return to pre-outbreak levels. The last Zika virus disease case detected by real-time, reverse transcription-polymerase chain reaction (rRT-PCR) occurred in a patient who had symptom onset on June 19, 2016. In August 2016, ASDoH requested CDC support in assessing whether local transmission had been reduced or interrupted and in proposing a timeline for discontinuation of routine testing of asymptomatic pregnant women. An end date (October 15, 2016) was determined for active mosquito-borne transmission of Zika virus and a timeline was developed for discontinuation of routine screening of asymptomatic pregnant women in American Samoa (conception after December 10, 2016, with permissive testing for asymptomatic women who conceive through April 15, 2017).

  17. Using the failure mode and effects analysis model to improve parathyroid hormone and adrenocorticotropic hormone testing

    PubMed Central

    Magnezi, Racheli; Hemi, Asaf; Hemi, Rina

    2016-01-01

    Background Risk management in health care systems applies to all hospital employees and directors as they deal with human life and emergency routines. There is a constant need to decrease risk and increase patient safety in the hospital environment. The purpose of this article is to review the laboratory testing procedures for parathyroid hormone and adrenocorticotropic hormone (which are characterized by short half-lives) and to track failure modes and risks, and offer solutions to prevent them. During a routine quality improvement review at the Endocrine Laboratory in Tel Hashomer Hospital, we discovered these tests are frequently repeated unnecessarily due to multiple failures. The repetition of the tests inconveniences patients and leads to extra work for the laboratory and logistics personnel as well as the nurses and doctors who have to perform many tasks with limited resources. Methods A team of eight staff members accompanied by the Head of the Endocrine Laboratory formed the team for analysis. The failure mode and effects analysis model (FMEA) was used to analyze the laboratory testing procedure and was designed to simplify the process steps and indicate and rank possible failures. Results A total of 23 failure modes were found within the process, 19 of which were ranked by level of severity. The FMEA model prioritizes failures by their risk priority number (RPN). For example, the most serious failure was the delay after the samples were collected from the department (RPN =226.1). Conclusion This model helped us to visualize the process in a simple way. After analyzing the information, solutions were proposed to prevent failures, and a method to completely avoid the top four problems was also developed. PMID:27980440

  18. Fecal Calprotectin Test Performed at Home: A Prospective Study of Pediatric Patients With Inflammatory Bowel Disease.

    PubMed

    Piekkala, Maija; Alfthan, Henrik; Merras-Salmio, Laura; Puustinen Wikström, Anne; Heiskanen, Kaarina; Jaakkola, Tytti; Klemetti, Paula; Md, Martti Färkkilä; Kolho, Kaija-Leena

    2018-06-01

    Measuring fecal calprotectin (FC) in a laboratory is time-consuming and that is why home tests have been developed. We studied the use of an FC home test in pediatric patients with inflammatory bowel disease (PIBD) in real-life settings. The patients were asked to perform the IBDoc FC home test monthly for 6 months and to report their clinical disease activity at testing. Clinical decision-making, however, was guided by routine FC enzyme-linked immunosorbent assay (ELISA) for patients with raised IBDoc values. Spare frozen samples were analyzed using ELISA and IBDoc in the laboratory. The participants completed a questionnaire about FC testing at the start and end of the study. Of the 52 patients, 35 (67%) ages 5 to 18 years completed the study, and 197 home tests were performed. Of these, 15% failed, mainly because of technical reasons. Just under half of the patients (47%) considered home testing comparable or superior to routine testing. In contrast, the parents were unsatisfied (61%), mostly because the IBDoc results were significantly different from ELISA and they found the phone application difficult to handle but whenever the IBDoc was performed by a laboratory professional it was comparable with ELISA, suggesting that practical issues hampered home testing. Despite their reservations, more than 80% of parents felt that home testing would improve disease management. PIBD patients and their families were interested in FC home monitoring and willing to adopt testing as a part of their disease management, but this approach requires thorough guidance.

  19. Improving laboratory results turnaround time by reducing pre analytical phase.

    PubMed

    Khalifa, Mohamed; Khalid, Parwaiz

    2014-01-01

    Laboratory turnaround time is considered one of the most important indicators of work efficiency in hospitals, physicians always need timely results to take effective clinical decisions especially in the emergency department where these results can guide physicians whether to admit patients to the hospital, discharge them home or do further investigations. A retrospective data analysis study was performed to identify the effects of ER and Lab staff training on new routines for sample collection and transportation on the pre-analytical phase of turnaround time. Renal profile tests requested by the ER and performed in 2013 has been selected as a sample, and data about 7,519 tests were retrieved and analyzed to compare turnaround time intervals before and after implementing new routines. Results showed significant time reduction on "Request to Sample Collection" and "Collection to In Lab Delivery" time intervals with less significant improvement on the analytical phase of the turnaround time.

  20. Evaluation of Targeted Next-Generation Sequencing for Detection of Bovine Pathogens in Clinical Samples.

    PubMed

    Anis, Eman; Hawkins, Ian K; Ilha, Marcia R S; Woldemeskel, Moges W; Saliki, Jeremiah T; Wilkes, Rebecca P

    2018-07-01

    The laboratory diagnosis of infectious diseases, especially those caused by mixed infections, is challenging. Routinely, it requires submission of multiple samples to separate laboratories. Advances in next-generation sequencing (NGS) have provided the opportunity for development of a comprehensive method to identify infectious agents. This study describes the use of target-specific primers for PCR-mediated amplification with the NGS technology in which pathogen genomic regions of interest are enriched and selectively sequenced from clinical samples. In the study, 198 primers were designed to target 43 common bovine and small-ruminant bacterial, fungal, viral, and parasitic pathogens, and a bioinformatics tool was specifically constructed for the detection of targeted pathogens. The primers were confirmed to detect the intended pathogens by testing reference strains and isolates. The method was then validated using 60 clinical samples (including tissues, feces, and milk) that were also tested with other routine diagnostic techniques. The detection limits of the targeted NGS method were evaluated using 10 representative pathogens that were also tested by quantitative PCR (qPCR), and the NGS method was able to detect the organisms from samples with qPCR threshold cycle ( C T ) values in the 30s. The method was successful for the detection of multiple pathogens in the clinical samples, including some additional pathogens missed by the routine techniques because the specific tests needed for the particular organisms were not performed. The results demonstrate the feasibility of the approach and indicate that it is possible to incorporate NGS as a diagnostic tool in a cost-effective manner into a veterinary diagnostic laboratory. Copyright © 2018 Anis et al.

  1. 42 CFR 493.1210 - Condition: Routine chemistry.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Routine chemistry. 493.1210 Section 493....1210 Condition: Routine chemistry. If the laboratory provides services in the subspecialty of Routine chemistry, the laboratory must meet the requirements specified in §§ 493.1230 through 493.1256, § 493.1267...

  2. 42 CFR 493.1210 - Condition: Routine chemistry.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Condition: Routine chemistry. 493.1210 Section 493....1210 Condition: Routine chemistry. If the laboratory provides services in the subspecialty of Routine chemistry, the laboratory must meet the requirements specified in §§ 493.1230 through 493.1256, § 493.1267...

  3. 42 CFR 493.1210 - Condition: Routine chemistry.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Condition: Routine chemistry. 493.1210 Section 493....1210 Condition: Routine chemistry. If the laboratory provides services in the subspecialty of Routine chemistry, the laboratory must meet the requirements specified in §§ 493.1230 through 493.1256, § 493.1267...

  4. 42 CFR 493.1210 - Condition: Routine chemistry.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Condition: Routine chemistry. 493.1210 Section 493....1210 Condition: Routine chemistry. If the laboratory provides services in the subspecialty of Routine chemistry, the laboratory must meet the requirements specified in §§ 493.1230 through 493.1256, § 493.1267...

  5. 42 CFR 493.1210 - Condition: Routine chemistry.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Condition: Routine chemistry. 493.1210 Section 493....1210 Condition: Routine chemistry. If the laboratory provides services in the subspecialty of Routine chemistry, the laboratory must meet the requirements specified in §§ 493.1230 through 493.1256, § 493.1267...

  6. New generation mix-designs : laboratory-field testing and modifications to Texas HMA mix-design procedures.

    DOT National Transportation Integrated Search

    2012-10-01

    Recent changes to the Texas hot mix asphalt (HMA) mix-design procedures such as adaption of the higher-stiffer PG asphalt-binder grades and the Hamburg test have ensured that the mixes that are routinely used on the Texas highways are not prone to ru...

  7. Role of phenotypic and genetic testing in managing clopidogrel therapy.

    PubMed

    Chan, Noel C; Eikelboom, John W; Ginsberg, Jeffrey S; Lauw, Mandy N; Vanassche, Thomas; Weitz, Jeffrey I; Hirsh, Jack

    2014-07-31

    The P2Y12 inhibitors, clopidogrel, prasugrel, and ticagrelor, are administered in fixed doses without laboratory monitoring. Randomized trials in acute coronary syndrome have shown that prasugrel and ticagrelor are more effective than standard-dose clopidogrel. Nonetheless, standard-dose clopidogrel remains widely used because it causes less bleeding and is less expensive. Patients treated with standard-dose clopidogrel have substantial variability in platelet inhibition, which is partly explained by genetic polymorphisms encoding CYP2C19, the hepatic enzyme involved in biotransformation of clopidogrel to its active metabolite. Some advocate tailoring P2Y12 inhibitor therapy according to the results of routine laboratory testing. Although there is good evidence for analytic, biological, and clinical validity of several phenotypic and genotypic biomarkers, the benefit of a management strategy that incorporates routine biomarker testing over standard of care without such testing remains unproven. Appropriately designed, adequately powered trials are needed but face the challenges of feasibility, cost, and the progressive switch from clopidogrel to prasugrel or ticagrelor. © 2014 by The American Society of Hematology.

  8. Reagent and labor cost optimization through automation of fluorescence in situ hybridization (FISH) with the VP 2000: an Italian case study.

    PubMed

    Zanatta, Lucia; Valori, Laura; Cappelletto, Eleonora; Pozzebon, Maria Elena; Pavan, Elisabetta; Dei Tos, Angelo Paolo; Merkle, Dennis

    2015-02-01

    In the modern molecular diagnostic laboratory, cost considerations are of paramount importance. Automation of complex molecular assays not only allows a laboratory to accommodate higher test volumes and throughput but also has a considerable impact on the cost of testing from the perspective of reagent costs, as well as hands-on time for skilled laboratory personnel. The following study tracked the cost of labor (hands-on time) and reagents for fluorescence in situ hybridization (FISH) testing in a routine, high-volume pathology and cytogenetics laboratory in Treviso, Italy, over a 2-y period (2011-2013). The laboratory automated FISH testing with the VP 2000 Processor, a deparaffinization, pretreatment, and special staining instrument produced by Abbott Molecular, and compared hands-on time and reagent costs to manual FISH testing. The results indicated significant cost and time saving when automating FISH with VP 2000 when more than six FISH tests were run per week. At 12 FISH assays per week, an approximate total cost reduction of 55% was observed. When running 46 FISH specimens per week, the cost saving increased to 89% versus manual testing. The results demonstrate that the VP 2000 processor can significantly reduce the cost of FISH testing in diagnostic laboratories. © 2014 Society for Laboratory Automation and Screening.

  9. Evaluation of a multiresidue method for measuring fourteen chemical groups of pesticides in water by use of LC-MS-MS.

    PubMed

    Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F

    2008-11-01

    European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.

  10. The LabTube - a novel microfluidic platform for assay automation in laboratory centrifuges.

    PubMed

    Kloke, A; Fiebach, A R; Zhang, S; Drechsel, L; Niekrawietz, S; Hoehl, M M; Kneusel, R; Panthel, K; Steigert, J; von Stetten, F; Zengerle, R; Paust, N

    2014-05-07

    Assay automation is the key for successful transformation of modern biotechnology into routine workflows. Yet, it requires considerable investment in processing devices and auxiliary infrastructure, which is not cost-efficient for laboratories with low or medium sample throughput or point-of-care testing. To close this gap, we present the LabTube platform, which is based on assay specific disposable cartridges for processing in laboratory centrifuges. LabTube cartridges comprise interfaces for sample loading and downstream applications and fluidic unit operations for release of prestored reagents, mixing, and solid phase extraction. Process control is achieved by a centrifugally-actuated ballpen mechanism. To demonstrate the workflow and functionality of the LabTube platform, we show two LabTube automated sample preparation assays from laboratory routines: DNA extractions from whole blood and purification of His-tagged proteins. Equal DNA and protein yields were observed compared to manual reference runs, while LabTube automation could significantly reduce the hands-on-time to one minute per extraction.

  11. Development and Validation of a Laboratory-Developed Multiplex Real-Time PCR Assay on the BD Max System for Detection of Herpes Simplex Virus and Varicella-Zoster Virus DNA in Various Clinical Specimens.

    PubMed

    Pillet, Sylvie; Verhoeven, Paul O; Epercieux, Amélie; Bourlet, Thomas; Pozzetto, Bruno

    2015-06-01

    A multiplex real-time PCR (quantitative PCR [qPCR]) assay detecting herpes simplex virus (HSV) and varicella-zoster virus (VZV) DNA together with an internal control was developed on the BD Max platform combining automated DNA extraction and an open amplification procedure. Its performance was compared to those of PCR assays routinely used in the laboratory, namely, a laboratory-developed test for HSV DNA on the LightCycler instrument and a test using a commercial master mix for VZV DNA on the ABI7500fast system. Using a pool of negative cerebrospinal fluid (CSF) samples spiked with either calibrated controls for HSV-1 and VZV or dilutions of a clinical strain that was previously quantified for HSV-2, the empirical limit of detection of the BD Max assay was 195.65, 91.80, and 414.07 copies/ml for HSV-1, HSV-2, and VZV, respectively. All the samples from HSV and VZV DNA quality control panels (Quality Control for Molecular Diagnostics [QCMD], 2013, Glasgow, United Kingdom) were correctly identified by the BD Max assay. From 180 clinical specimens of various origins, 2 CSF samples were found invalid by the BD Max assay due to the absence of detection of the internal control; a concordance of 100% was observed between the BD Max assay and the corresponding routine tests. The BD Max assay detected the PCR signal 3 to 4 cycles earlier than did the routine methods. With results available within 2 h on a wide range of specimens, this sensitive and fully automated PCR assay exhibited the qualities required for detecting simultaneously HSV and VZV DNA on a routine basis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  12. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.

    PubMed

    Kocijancic, Marija; Cargonja, Jelena; Delic-Knezevic, Alma

    2014-01-01

    Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer(®) RST blood collection tube in reference with the BD Vacutainer(®) Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality. Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C. Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.

  13. [Blood volume for biochemistry determinations--laboratory needs and everyday practice].

    PubMed

    Sztefko, Krystyna; Mamica, Katarzyna; Bugajska, Jolanta; Maziarz, Barbara; Tomasik, Przemysław

    2014-01-01

    Blood loss due to diagnostic phlebotomy jest a very serious problem, especially for newborn, infants and critically ill patients on intensive care units. Although single blood loss can be easily tolerated in adults, in small babies and in patients who are frequently monitored based on laboratory tests iatrogenic anaemia can occur. To evaluate the blood volume drawn for routine biochemistry tests in relation to patient age and the number of parameters requested. Blood volume drawn for routine biochemistry measurements from patients hospitalized in University Children's Hospital (N = 2980, children age from one day to 18 years) and in University Hospital (N = 859, adults, aged > 1.8 years) in Cracow has been analyzed. Blood volume was calculated based on regular tube diameter and blood heights in the tube. In case of microvettes the blood volume was 0.2 ml. Statistical analysis has been performed by using PRISM 5.0. The statistical significance was set at p < 0.05. The mean values of blood volume were 3.02 +/- 0.92 ml and 4.12 +/- 0.68 ml in children and adults, respectively. Analyzing blood volume drawn in children using both microvettes and regular tubes, significant correlation between blood volume and patient age (p < 0.001) as well the number of requested parameters (p < 0.001). The latest relationship was true only for up to five parameters. However, analyzing the blood volume drawn into only into regular tubes blood volume was not related to patients age and number of laboratory tests requested. The proportion of microvettes used for blood collection was highest for newborns and infants, and in all cases where only one to three laboratory tests were requested. 1. All educational programs for nurses and doctors should include the information about current laboratory automation and methods miniaturization; 2) The amount of blood volume needed by laboratory for the requested number of tests should always be taken into account when diagnostic phlebotomy is necessary.

  14. Laboratory Diagnostics Market in East Africa: A Survey of Test Types, Test Availability, and Test Prices in Kampala, Uganda.

    PubMed

    Schroeder, Lee F; Elbireer, Ali; Jackson, J Brooks; Amukele, Timothy K

    2015-01-01

    Diagnostic laboratory tests are routinely defined in terms of their sensitivity, specificity, and ease of use. But the actual clinical impact of a diagnostic test also depends on its availability and price. This is especially true in resource-limited settings such as sub-Saharan Africa. We present a first-of-its-kind report of diagnostic test types, availability, and prices in Kampala, Uganda. Test types (identity) and availability were based on menus and volumes obtained from clinical laboratories in late 2011 in Kampala using a standard questionnaire. As a measure of test availability, we used the Availability Index (AI). AI is the combined daily testing volumes of laboratories offering a given test, divided by the combined daily testing volumes of all laboratories in Kampala. Test prices were based on a sampling of prices collected in person and via telephone surveys in 2015. Test volumes and menus were obtained for 95% (907/954) of laboratories in Kampala city. These 907 laboratories offered 100 different test types. The ten most commonly offered tests in decreasing order were Malaria, HCG, HIV serology, Syphilis, Typhoid, Urinalysis, Brucellosis, Stool Analysis, Glucose, and ABO/Rh. In terms of AI, the 100 tests clustered into three groups: high (12 tests), moderate (33 tests), and minimal (55 tests) availability. 50% and 36% of overall availability was provided through private and public laboratories, respectively. Point-of-care laboratories contributed 35% to the AI of high availability tests, but only 6% to the AI of the other tests. The mean price of the most commonly offered test types was $2.62 (range $1.83-$3.46). One hundred different laboratory test types were in use in Kampala in late 2011. Both public and private laboratories were critical to test availability. The tests offered in point-of-care laboratories tended to be the most available tests. Prices of the most common tests ranged from $1.83-$3.46.

  15. Interlaboratory discrepancy of antigenuria results in 2 patients with AIDS and histoplasmosis.

    PubMed

    McKinsey, David S; McKinsey, Joel P; Northcutt, Noelle; Sarria, Juan C

    2009-01-01

    Histoplasma polysaccharide antigen testing is used routinely to diagnose histoplasmosis. At least 3 antigen tests are commercially available. Controversy exists about the relative accuracy of these tests. We report 2 patients with AIDS and culture-confirmed Histoplasma capsulatum meningitis from whom discrepant Histoplasma polysaccharide antigen results were obtained from different laboratories and discuss the potential clinical implications of these results.

  16. Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.

    PubMed

    Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel

    2011-11-01

    Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.

  17. Audit of Helicobacter pylori Testing in Microbiology Laboratories in England: To Inform Compliance with NICE Guidance and the Feasibility of Routine Antimicrobial Resistance Surveillance

    PubMed Central

    Allison, Rosalie; Lecky, Donna M.; Bull, Megan; Turner, Kim; Godbole, Gauri

    2016-01-01

    Introduction. The National Institute for Health and Clinical Excellence (NICE) guidance recommends that dyspeptic patients are tested for Helicobacter pylori using a urea breath test, stool antigen test, or serology. Antibiotic resistance in H. pylori is globally increasing, but treatment in England is rarely guided by susceptibility testing or surveillance. Aims. To determine compliance of microbiology laboratories in England with NICE guidance and whether laboratories perform culture and antibiotic susceptibility testing (AST). Methods. In 2015, 170 accredited English microbiology laboratories were surveyed, by email. Results. 121/170 (71%) laboratories responded; 96% provided H. pylori testing (78% on site). 94% provided H. pylori diagnosis using stool antigen; only four provided serology as their noninvasive test; 3/4 of these encouraged urea breath tests in their acute trusts. Only 22/94 (23%) of the laboratories performed H. pylori cultures from gastric biopsies on site; 9/22 performed AST, but the vast majority processed less than one specimen/week. Conclusions. Only five laboratories in England do not comply with NICE guidance; these will need the guidance reinforced. National surveillance needs to be implemented; culture-based AST would need to be centralised. Moving forward, detection of resistance in H. pylori from stool specimens using molecular methods (PCR) needs to be explored. PMID:27829836

  18. Human Toxocariasis: Prevalence and Factors Associated with Biosafety in Research Laboratories.

    PubMed

    Mattos, Gabriela Torres; Santos, Paula Costa Dos; Telmo, Paula de Lima; Berne, Maria Elisabeth Aires; Scaini, Carlos James

    2016-12-07

    Human toxocariasis is a neglected parasitic disease worldwide. Researchers studying this disease use infectious strains of Toxocara for experiments. Health workers are at risk in the course of their daily routine and must adhere to biosafety standards while carrying out the activities. Researchers on biosafety concerning working with these parasites are insufficient. The aim of this study was to determine the rate of seroprevalence of Toxocara species among health-care research laboratory workers (professors, technicians, and students), and to investigate the risk factors of Toxocara infection associated with laboratory practices. This cross-sectional study involved 74 researchers at two federal universities in southern Brazil from February 2014 to February 2015; 29 researchers manipulated infective strains of Toxocara canis (test group) and 45 did not (control group). Serum samples were examined using enzyme-linked immunosorbent assay. Epidemiological data were obtained via a questionnaire containing information about laboratory routine, eating behavior, and contact with dogs. The seroprevalence of anti-T. canis IgG was 14.9% (11/74; 13.8% [4/29] in the test group and 15.6% [7/45] in the control group). Most individuals in the test group correctly understood the primary mode of infection; however, 13.8% did not use gloves while manipulating T. canis eggs. Knowledge of biosafety must be well understood by health-care professionals doing laboratory work with biological agents. To our knowledge, this is the first study to investigate the rate of seroprevalence of IgG against Toxocara spp. among professionals and students who handle infective forms of the nematode T. canis. © The American Society of Tropical Medicine and Hygiene.

  19. Human Toxocariasis: Prevalence and Factors Associated with Biosafety in Research Laboratories

    PubMed Central

    Mattos, Gabriela Torres; dos Santos, Paula Costa; Telmo, Paula de Lima; Berne, Maria Elisabeth Aires; Scaini, Carlos James

    2016-01-01

    Human toxocariasis is a neglected parasitic disease worldwide. Researchers studying this disease use infectious strains of Toxocara for experiments. Health workers are at risk in the course of their daily routine and must adhere to biosafety standards while carrying out the activities. Researchers on biosafety concerning working with these parasites are insufficient. The aim of this study was to determine the rate of seroprevalence of Toxocara species among health-care research laboratory workers (professors, technicians, and students), and to investigate the risk factors of Toxocara infection associated with laboratory practices. This cross-sectional study involved 74 researchers at two federal universities in southern Brazil from February 2014 to February 2015; 29 researchers manipulated infective strains of Toxocara canis (test group) and 45 did not (control group). Serum samples were examined using enzyme-linked immunosorbent assay. Epidemiological data were obtained via a questionnaire containing information about laboratory routine, eating behavior, and contact with dogs. The seroprevalence of anti-T. canis IgG was 14.9% (11/74; 13.8% [4/29] in the test group and 15.6% [7/45] in the control group). Most individuals in the test group correctly understood the primary mode of infection; however, 13.8% did not use gloves while manipulating T. canis eggs. Knowledge of biosafety must be well understood by health-care professionals doing laboratory work with biological agents. To our knowledge, this is the first study to investigate the rate of seroprevalence of IgG against Toxocara spp. among professionals and students who handle infective forms of the nematode T. canis. PMID:27698276

  20. Adaptation to vestibular disorientation. II, Nystagmus and vertigo following high-velocity angular accelerations.

    DOT National Transportation Integrated Search

    1965-09-01

    Professional figure skaters who, as part of their daily routine, subject themselves to high levels of disorientation-and vertigo-producing stimuli, were given a series of laboratory tests consisting primarily of caloric irrigations and mild angular a...

  1. Diagnostic performances of clinical laboratory tests using Triton X-100 to reduce the biohazard associated with routine testing of Ebola virus-infected patients.

    PubMed

    Tempestilli, Massimo; Pucci, Luigia; Notari, Stefania; Di Caro, Antonino; Castilletti, Concetta; Rivelli, Maria Rosaria; Agrati, Chiara; Pucillo, Leopoldo Paolo

    2015-11-01

    Ebola virus, an enveloped virus, is the cause of the largest and most complex Ebola virus disease (EVD) outbreak in West Africa. Blood or body fluids of an infected person may represent a biohazard to laboratory workers. Laboratory tests of virus containing specimens should be conducted in referral centres at biosafety level 4, but based on the severity of clinical symptoms, basic laboratories might be required to execute urgent tests for patients suspected of EVD. The aim of this work was to compare the analytical performances of laboratory tests when Triton X-100, a chemical agent able to inactivate other enveloped viruses, was added to specimens. Results of clinical chemistry, coagulation and haematology parameters on samples before and after the addition of 0.1% (final concentration) of Triton X-100 and 1 h of incubation at room temperature were compared. Overall, results showed very good agreement by all statistical analyses. Triton X-100 at 0.1% did not significantly affect the results for the majority of the analytes tested. Triton X-100 at 0.1% can be used to reduce the biohazard in performing laboratory tests on samples from patients with EVD without affecting clinical decisions.

  2. Are biochemistry interpretative comments helpful? Results of a general practitioner and nurse practitioner survey.

    PubMed

    Barlow, Ian M

    2008-01-01

    Adding or incorporating clinical interpretative comments on biochemistry results is widespread in UK laboratories; although this consumes considerable human resource, there is still little evidence to suggest that it is either effective or appreciated by our clinical colleagues. I therefore decided to survey our local general practitioners (GPs) and nurse practitioners to analyse whether they found biochemistry comments on reports helpful. A simple questionnaire was designed and sent to 159 GPs and 81 nurse practitioners asking them whether they found this activity useful for the limited range of test groups that we routinely comment on and also whether they would like to see commenting on more groups of tests. Overall, 49.6% of questionnaires were returned. Of these, there was overwhelming support for commenting on reports and 77% would like to see comments on a greater range of tests. Although adding clinical interpretative comments is very time-consuming for senior laboratory staff, there is overwhelming support of this activity among our GPs and nurse practitioner users; therefore, our local policy of routinely adding clinical comments will remain for the foreseeable future.

  3. Summary of aluminum nitrate tests at the F/H-ETF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCabe, D.J.; Wiggins, A.W.

    1992-05-01

    Biofouling of the Norton ceramic filters in the F/H Effluent Treatment Facility (ETF) has been minimized by bacterial control strategies on the influent streams. However, enough bacteria still exists in the routine influent to impact the filter performance. One method of remediating biofouling in routine influent, initially observed in laboratory tests on simulant solutions, involves addition of aluminum nitrate to the influent wastewater. Tests on actual feed at the ETF using aluminum nitrate showed significantly improved performance, with increases in filter permeability of up to four-fold compared to the baseline case. These improvements were only realized after modifications to themore » pH adjustment system were completed which minimized upsets in the pH of the feed solutions.« less

  4. Routine testing of Mycoplasma genitalium and Trichomonas vaginalis.

    PubMed

    Jenniskens, Marieke L M; Veerbeek, Jan H W; Deurloo, Koen L; van Hannen, Erik J; Thijsen, Steven F T

    2017-06-01

    Mycoplasma genitalium (MG) and Trichomonas vaginalis (TV) are common sexual transmitted infections (STI). However, most STI screening programmes do not include routinely detection of these pathogens. Consequently, epidemiological data about MG and TV in the general population is lacking. The current study aims to give insight into the prevalence of both infections, thereby guiding decisions whether testing for these pathogens should be included routinely. Between February 2013 and August 2015, all samples sent to the laboratory of Diakonessenhuis Utrecht for STI testing (i.e. testing for Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG)) were additionally examined for the presence of MG and TV by means of a laboratory-developed RT-PCR. Samples were collected by our hospital or by regional general practitioners. A total of 5628 PCR's were evaluated. In 7.5%, one or more STI were detected. CT was found in 5% and MG was positive in 1.9%. NG was detected in 0.5% and TV was detected in 0.6% of the samples. CT was found more often in primary care than in hospital setting (9.7% vs. 3.0%, p < .05). The same was shown for NG (1.1% vs. 0.2%, p < .05). More men than women were positive for CT (11.2% vs. 3.8%, p < .05) and NG (1.4% vs. 0.3%, p < .05). MG is more prevalent than NG and TV in a regional Dutch population. Furthermore, TV is equally common as NG. Based on our prevalence data, including MG and TV in STI testing protocols should be considered in the future.

  5. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    PubMed

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  6. Increased Cannabinoids Concentrations Found in Specimens From Fatal Aviation Accidents Between 1997 and 2006

    DTIC Science & Technology

    2009-06-01

    Work was accomplished under approved task AM-B-09-TOX-206. 16. Abstract The Civil Aerospace Medical Institute’s toxicology laboratory...routine analysis of pilot specimens, the laboratory tests all cases for the presence of marijuana ( cannabis ). The National Institute on Drug Abuse... cannabis seizures from1997-2001 to 2002-2006. This study was conducted to compare the changes, over those years, in blood and urine cannabinoid

  7. Measurement of the setting expansion of phosphate-bonded investment materials: Part I - Development of the Casting-Ring Test.

    PubMed

    Lloyd, C H; Yearn, J A; Cowper, G A; Blavier, J; Vanderdonckt, M

    2004-07-01

    The setting expansion is an important property for a phosphate-bonded investment material. This research was undertaken to investigate a test that might be suitable for its measurement when used in a Standard. In the 'Casting-Ring Test', the investment sample is contained in a steel ring and expands to displace a precisely positioned pin. Variables with the potential to alter routine reproduction of the value were investigated. The vacuum-mixer model is a production laboratory variable that must not be ignored and for this reason, experiments were repeated using a different vacuum-mixer located at a second test site. Restraint by the rigid ring material increased expansion, while force on the pin reduced it. Expansion was specific to the lining selected. Increased environmental temperature decreased the final value. Expansion was still taking place at a time at which its value might be measured. However, when these factors are set, the reproducibility of values for setting expansion was good at both test sites (coefficient of variation 14%, at most). The results revealed that with the control that is available reliable routine measurement is possible in a Standard test. The inter-laboratory variable, vacuum-mixer model, produced significant differences and it should be the subject of further investigation.

  8. Has compliance with CLIA requirements really improved quality in US clinical laboratories?

    PubMed

    Ehrmeyer, Sharon S; Laessig, Ronald H

    2004-08-02

    The Clinical Laboratory Improvement Amendments of 1988 (CLIA'88) mandate universal requirements for all U.S. clinical laboratory-testing sites. The intent of CLIA'88 is to ensure quality testing through a combination of minimum quality practices that incorporate total quality management concepts. These regulations do not contain established, objective indicators or measures to assess quality. However, there is an implicit assumption that compliance with traditionally accepted good laboratory practices--following manufacturers' directions, routinely analysing quality control materials, applying quality assurance principles, employing and assessing competent testing personnel, and participating in external quality assessment or proficiency testing (PT)--will result in improved test quality. The CLIA'88 regulations do include PT performance standards, which intentionally or unintentionally, define intra-laboratory performance. Passing PT has become a prime motivation for improving laboratory performance; it can also be used as an objective indicator to assess whether compliance to CLIA has improved intra-laboratory quality. Data from 1994 through 2002 indicate that the percentage of laboratories passing PT has increased. In addition to PT performance, subjective indicators of improved quality--frequency of inspection deficiencies, the number of government sanctions for non-compliance, and customer satisfaction--were evaluated. The results from these subjective indicators are more difficult to interpret but also seem to show improved quality in US clinical laboratories eleven years post-CLIA'88.

  9. Prevalence of Estimated GFR Reporting Among US Clinical Laboratories

    PubMed Central

    Accetta, Nancy A.; Gladstone, Elisa H.; DiSogra, Charles; Wright, Elizabeth C.; Briggs, Michael; Narva, Andrew S.

    2008-01-01

    Background Routine laboratory reporting of estimated glomerular filtration rate (eGFR) may help clinicians detect kidney disease. The current national prevalence of eGFR reporting among clinical laboratories is unknown, thus the extent of the situation of laboratories not routinely reporting eGFR with serum creatinine (SCr) results is not quantified. Design Observational analysis. Setting National Kidney Disease Education Program survey of clinical laboratory conducted in 2006-7 by mail, Web, and telephone follow up. Participants A national random sample, 6,350 clinical laboratories, drawn from the Federal Clinical Laboratory Improvement Amendments database and stratified by six major laboratory types/groupings. Predictors Laboratory reports SCr results. Outcomes Reporting eGFR values along with SCr results. Measurements Percent of laboratories reporting eGFR along with reporting SCr, reporting protocol, eGFR formula used, and style of reporting cutoff values. Results Among laboratories reporting SCr, 38.4% report eGFR (physician offices, 25.8%; hospitals, 43.6%; independents, 38.9%; community clinics, 47.2%; health fair/insurance/public health, 45.5%; others, 43.2%). Physician office laboratories have a reporting prevalence lower than other laboratory types (p < 0.001). Among laboratories reporting eGFR, 66.7% do so routinely with all adult SCr determinations; 71.6% use the 4-variable Modification of Diet in Renal Disease Study equation; and 45.3% use the “>60 mL/min/1.73 m2” reporting convention. Independent laboratories are least likely to routinely report eGFR, (50.6%, p < .05) and most likely to report only when specifically requested (45.4%, p < 0.05). High-volume laboratories across all strata are more likely to report eGFR (p < 0.001). Limitations Self-reporting by laboratories, Federal database did not have names of laboratory directors/managers (intended respondents), assumed accuracy of Federal database for sample purposes. Conclusions Routine eGFR reporting with SCr is not yet universal and laboratories vary in their reporting practices. PMID:18676076

  10. Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program.

    PubMed

    Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W

    2011-08-01

    The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h.

  11. Molecular genetic testing for cystic fibrosis: laboratory performance on the College of American Pathologists external proficiency surveys.

    PubMed

    Lyon, Elaine; Schrijver, Iris; Weck, Karen E; Ferreira-Gonzalez, Andrea; Richards, C Sue; Palomaki, Glenn E

    2015-03-01

    Molecular testing for cystic fibrosis mutations is widespread and routine in reproductive decision making and diagnosis. Our objective was to assess the level of performance of laboratories for this test. The College of American Pathologists administers external proficiency testing with multiple DNA samples distributed biannually. RESULTS are analyzed, reviewed, and graded by the joint College of American Pathologists/American College of Medical Genetics and Genomics Biochemical and Molecular Genetics Committee. Assessment is based on genotype and associated clinical interpretation. Overall, 357 clinical laboratories participated in the proficiency testing survey between 2003 and 2013 (322 in the United States and 35 international). In 2013, US participants reported performing nearly 120,000 tests monthly. Analytical sensitivity and specificity of US laboratories were 98.8% (95% confidence interval: 98.4-99.1%) and 99.6% (95% confidence interval: 99.4-99.7%), respectively. Analytical sensitivity improved between 2003 and 2008 (from 97.9 to 99.3%; P = 0.007) and remained steady thereafter. Clinical interpretation matched the intended response for 98.8, 86.0, and 91.0% of challenges with no, one, or two mutations, respectively. International laboratories performed similarly. Laboratory testing for cystic fibrosis in the United States has improved since 2003, and these data demonstrate a high level of quality. Neither the number of samples tested nor test methodology affected performance.

  12. External quality assessment unravels interlaboratory differences in quality of RAS testing for anti-EGFR therapy in colorectal cancer.

    PubMed

    Tack, Véronique; Ligtenberg, Marjolijn J L; Tembuyser, Lien; Normanno, Nicola; Vander Borght, Sara; Han van Krieken, J; Dequeker, Elisabeth M C

    2015-03-01

    Regulations for the selection of patients with metastatic colorectal cancer for anti-EGFR treatment changed at the end of 2013. The set of mutations to be tested extended from KRAS codons 12 and 13 to KRAS and NRAS exons 2, 3, and 4. A European external quality assessment scheme monitored the performance of laboratories and evaluated the implementation of the new regulations. The 131 participating laboratories received 10 samples of formalin-fixed paraffin-embedded material, including RAS (exon 2, 3, 4) and BRAF mutations. Mock clinical data were provided for three cases. Using their routine methods, laboratories determined the genotypes and submitted three written reports. Assessors scored the results according to predefined evaluation criteria. Half of the participants (49.3%) had completely implemented the new test requirements (codons 12, 13, 59, 61, 117, and 146 of KRAS and NRAS), and 96 laboratories (73.3%) made no genotype mistakes. Correct nomenclature, according to the Human Genome Variation Society, was used by 82 laboratories (62.6%). Although regulations were effective for several months, many laboratories were not ready for full RAS testing in the context of anti-EGFR therapy. Nevertheless, in each participating country, there are laboratories that provide complete and correct testing. External quality assessments can be used to monitor implementation of new test regulations and to stimulate the laboratories to improve their testing procedures. Because the results of this program are available on the website of the European Society of Pathology, patients and clinicians can refer test samples to a reliable laboratory. ©AlphaMed Press.

  13. Analysis and Presentation of Cumulative Antimicrobial Susceptibility Test Data--The Influence of Different Parameters in a Routine Clinical Microbiology Laboratory.

    PubMed

    Kohlmann, Rebekka; Gatermann, Sören G

    2016-01-01

    Many clinical microbiology laboratories report on cumulative antimicrobial susceptibility testing (cAST) data on a regular basis. Criteria for generation of cAST reports, however, are often obscure and inconsistent. Whereas the CLSI has published a guideline for analysis and presentation of cAST data, national guidelines directed at clinical microbiology laboratories are not available in Europe. Thus, we sought to describe the influence of different parameters in the process of cAST data analysis in the setting of a German routine clinical microbiology laboratory during 2 consecutive years. We developed various program scripts to assess the consequences ensuing from different algorithms for calculation of cumulative antibiograms from the data collected in our clinical microbiology laboratory in 2013 and 2014. One of the most pronounced effects was caused by exclusion of screening cultures for multi-drug resistant organisms which decreased the MRSA rate in some cases to one third. Dependent on the handling of duplicate isolates, i.e. isolates of the same species recovered from successive cultures on the same patient during the time period analyzed, we recorded differences in resistance rates of up to 5 percentage points for S. aureus, E. coli and K. pneumoniae and up to 10 percentage points for P. aeruginosa. Stratification by site of care and specimen type, testing of antimicrobials selectively on resistant isolates, change of interpretation rules and analysis at genus level instead of species level resulted in further changes of calculated antimicrobial resistance rates. The choice of parameters for cAST data analysis may have a substantial influence on calculated antimicrobial resistance rates. Consequently, comparability of cAST reports from different clinical microbiology laboratories may be limited. We suggest that laboratories communicate the strategy used for cAST data analysis as long as national guidelines for standardized cAST data analysis and reporting do not exist in Europe.

  14. Computer-Based Techniques for Collection of Pulmonary Function Variables during Rest and Exercise.

    DTIC Science & Technology

    1991-03-01

    routinely Included in experimental protocols involving hyper- and hypobaric excursions. Unfortunately, the full potential of those tests Is often not...for a Pulmonary Function data acquisition system that has proven useful in the hyperbaric research laboratory. It illustrates how computers can

  15. [Medical supports for the diagnosis of infectious diseases; the role and responsibilities of clinical pathologist and microbiology technologist. Acute purulent meningitis; the position of the technologists in microbiology laboratory].

    PubMed

    Misawa, Shigeki

    2002-07-01

    The features and limitations of microbiology processes for the diagnosis of bacterial meningitis were summarized. Requests for physicians were also emphasized. The microbiology laboratory should be responsible for providing highly reliable and concordant data with a variety of clinical settings. Technologists in a microbiology laboratory should perform following subjects: i) Direct smear examination: Presumptive identification by the observers with abundant experience and sufficient training. ii) Rapid bacterial antigen detection tests: Active utilize alone in combination with the direct microscopy. iii) Culture: Cost effective utilize for appropriate media and culture condition based on the bacteriological statistics. Report with bacteriological interpretations and with additional proper comments, if necessary. iv) Antimicrobial susceptibility tests: Determination of penicillin resistance among the strains of penicillin-resistant or-intermediate Streptococcus pneumoniae (PI or PRSP) should be confirmed by MIC procedures; Detection of beta-lactamase producing Haemophilus influenzae (BLP) could detect by beta-lactamase tests, but not clearly identify for beta-lactamase-negative ampicillin-resistant isolates (BLNAR). In addition, a laboratory should provide appropriate information by using the accumulated routine clinical microbiology data, which may help to physicians in selecting an empiric therapy and to the microbiology technologists in processing the routine microbiology. In recent status, the most common organisms isolated from patients with bacterial meningitis continue to be S. pneumoniae and H. influenzae. Among S. pneumoniae strains, penicillin-intermediate(PISP) and--resistant(PRSP) strains had exceeded 50%, and the strains of beta-lactamase producing H. influenzae (BLP) had decreased with less than 10% and beta-lactamase negative ampicillin-resistant strains (BLNAR) have increasing. To providing rapid and accurate results, a laboratory should require the clinical information, including patient's age, major presenting symptoms, and receive antimicrobials prior to specimen collection.

  16. Is maternal plasma DNA testing impacting serum-based screening for aneuploidy in the United States?

    PubMed

    Palomaki, Glenn E; Ashwood, Edward R; Best, Robert G; Lambert-Messerlian, Geralyn; Knight, George J

    2015-11-01

    We sought to determine whether tests for fetal aneuploidy based on next-generation sequencing of cell-free DNA in maternal circulation have had an impact on routine serum-based screening in the general pregnant population. We compared results from laboratory surveys in 2011 and 2014 that reported types of prenatal serum screening tests and numbers of tests performed. Testing records from two prenatal serum screening laboratories examined temporal trends in the proportion of screened women 35 years of age and older from 2008 (or 2009) to 2014. The 82 laboratory survey results available for comparison showed that 1.7 million women were screened in 2014, a 5% increase over 2011. In the two screening laboratories, the proportion of screened women age 35 and older increased for several years but then experienced reductions of 8 and 18% by mid-2014 when compared with the highest rates observed. As of 2014, maternal plasma DNA testing appears to have had only a minor impact on serum screening rates in the United States. Ongoing surveillance has the potential to determine if, and when, DNA testing begins to replace serum testing as a primary screen for Down syndrome in the United States.

  17. One simple DNA extraction device and its combination with modified visual loop-mediated isothermal amplification for rapid on-field detection of genetically modified organisms.

    PubMed

    Zhang, Miao; Liu, Yinan; Chen, Lili; Quan, Sheng; Jiang, Shimeng; Zhang, Dabing; Yang, Litao

    2013-01-02

    Quickness, simplicity, and effectiveness are the three major criteria for establishing a good molecular diagnosis method in many fields. Herein we report a novel detection system for genetically modified organisms (GMOs), which can be utilized to perform both on-field quick screening and routine laboratory diagnosis. In this system, a newly designed inexpensive DNA extraction device was used in combination with a modified visual loop-mediated isothermal amplification (vLAMP) assay. The main parts of the DNA extraction device included a silica gel membrane filtration column and a modified syringe. The DNA extraction device could be easily operated without using other laboratory instruments, making it applicable to an on-field GMO test. High-quality genomic DNA (gDNA) suitable for polymerase chain reaction (PCR) and isothermal amplification could be quickly isolated from plant tissues using this device within 15 min. In the modified vLAMP assay, a microcrystalline wax encapsulated detection bead containing SYBR green fluorescent dye was introduced to avoid dye inhibition and cross-contaminations from post-LAMP operation. The system was successfully applied and validated in screening and identification of GM rice, soybean, and maize samples collected from both field testing and the Grain Inspection, Packers, and Stockyards Administration (GIPSA) proficiency test program, which demonstrated that it was well-adapted to both on-field testing and/or routine laboratory analysis of GMOs.

  18. Comparison of two matrix-assisted laser desorption ionization-time of flight mass spectrometry methods with conventional phenotypic identification for routine identification of bacteria to the species level.

    PubMed

    Cherkaoui, Abdessalam; Hibbs, Jonathan; Emonet, Stéphane; Tangomo, Manuela; Girard, Myriam; Francois, Patrice; Schrenzel, Jacques

    2010-04-01

    Bacterial identification relies primarily on culture-based methodologies requiring 24 h for isolation and an additional 24 to 48 h for species identification. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) is an emerging technology newly applied to the problem of bacterial species identification. We evaluated two MALDI-TOF MS systems with 720 consecutively isolated bacterial colonies under routine clinical laboratory conditions. Isolates were analyzed in parallel on both devices, using the manufacturers' default recommendations. We compared MS with conventional biochemical test system identifications. Discordant results were resolved with "gold standard" 16S rRNA gene sequencing. The first MS system (Bruker) gave high-confidence identifications for 680 isolates, of which 674 (99.1%) were correct; the second MS system (Shimadzu) gave high-confidence identifications for 639 isolates, of which 635 (99.4%) were correct. Had MS been used for initial testing and biochemical identification used only in the absence of high-confidence MS identifications, the laboratory would have saved approximately US$5 per isolate in marginal costs and reduced average turnaround time by more than an 8-h shift, with no loss in accuracy. Our data suggest that implementation of MS as a first test strategy for one-step species identification would improve timeliness and reduce isolate identification costs in clinical bacteriology laboratories now.

  19. Apparatus Tests Thermocouples For Seebeck Inhomogeneity

    NASA Technical Reports Server (NTRS)

    Burkett, Cecil G., Jr.; Bauserman, Willard A., Jr.; West, James W.

    1995-01-01

    Automated apparatus reveals sources of error not revealed in calibration. Computer-controlled apparatus detects and measures Seebeck inhomogeneities in sheathed thermocouples. Measures thermocouple output voltage as function of position of probe along sharp gradient of temperature. Abnormal variations in voltage-versus-position data indicative of Seebeck inhomogeneities. Prototype for development of standard method and equipment for routine acceptance/rejection testing of sheathed thermocouples in industrial and research laboratories.

  20. Evaluation of the results of Mycobacterium tuberculosis direct test (MTD) and Mycobacterial culture in urine samples

    PubMed Central

    Sener, Asli Gamze; Kurultay, Nukhet; Afsar, Ilhan

    2008-01-01

    Tuberculosis remains a public health problem in Turkey. Rapid detection of Mycobacterium tuberculosis plays a key role in control of infection. In this article, the Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test (MTD) was evaluated for detection of M. tuberculosis in urine samples. The performance of the MTD was very good and appropriate for routine laboratory diagnosis. PMID:24031287

  1. Validation of the Sysmex sp-1000i automated slide preparer-stainer in a clinical laboratory

    PubMed Central

    de Bitencourt, Eberson Damião dos Santos; Voegeli, Carlos Franco; Onzi, Gabriela dos Santos; Boscato, Sara Cardoso; Ghem, Carine; Munhoz, Terezinha

    2013-01-01

    Background The speed and quality of information have become essential items in the release of laboratory reports. The Sysmex®SP1000-I device has been developed to prepare and stain smear slides. However, for a device to be cleared for use in the laboratory routine it must pass through a validation process. Objective To evaluate the performance and reliability of the Sysmex® SP-1000i slide preparer-stainer incorporated into the routine of a hospital laboratory in Porto Alegre. Methods Peripheral blood samples of patients attending the laboratory for ambulatory exams with leukocyte counts between 7000/°L and 12,000/°L were evaluated, independent of gender and age. Two slides were prepared for each sample using the Sysmex® SP-1000i equipment; one of the slides was used to perform quality control tests using the CellaVision® DM96 device, and the other slide was used to compare pre-classification by the same device and the classification performed by a pharmacist-biochemist. Results The results of all the slides used as controls were acceptable according to the quality control test as established by the manufacturer of the device. In the comparison between the automated pre-classification and the classification made by the professional, there was an acceptable variation in the differential counts of leukocytes for 90% of the analyzed slides. Pearson correlation coefficient showed a strong correlation for band neutrophils (r = 0.802; p-value < 0.001), segmented neutrophils (r = 0.963; p-value < 0.001), eosinophils (r = 0.958; p-value < 0.001), lymphocytes (r = 0.985; p-value < 0.001) and atypical lymphocytes (r = 0.866; p-value < 0.001) using both methods. The red blood cell analysis was adequate for all slides analyzed by the equipment and by the professional. Conclusion The new Sysmex®SP1000-i methodology was found to be reliable, fast and safe for the routines of medium and large laboratories, improving the quality of microscopic analysis in complete blood counts. PMID:24478606

  2. The cost-effectiveness of monitoring strategies for antiretroviral therapy of HIV infected patients in resource-limited settings: software tool.

    PubMed

    Estill, Janne; Salazar-Vizcaya, Luisa; Blaser, Nello; Egger, Matthias; Keiser, Olivia

    2015-01-01

    The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs.

  3. The Cost-Effectiveness of Monitoring Strategies for Antiretroviral Therapy of HIV Infected Patients in Resource-Limited Settings: Software Tool

    PubMed Central

    Estill, Janne; Salazar-Vizcaya, Luisa; Blaser, Nello; Egger, Matthias; Keiser, Olivia

    2015-01-01

    Background The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. Methods We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. Results Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. Conclusion Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs. PMID:25793531

  4. Electronic medical records and efficiency and productivity during office visits.

    PubMed

    Furukawa, Michael F

    2011-04-01

    To estimate the relationship between electronic medical record (EMR) use and efficiency of utilization and provider productivity during visits to US office-based physicians. Cross-sectional analysis of the 2006-2007 National Ambulatory Medical Care Survey. The sample included 62,710 patient visits to 2625 physicians. EMR systems included demographics, clinical notes, prescription orders, and laboratory and imaging results. Efficiency was measured as utilization of examinations, laboratory tests, radiology procedures, health education, nonmedication treatments, and medications. Productivity was measured as total services provided per 20-minute period. Survey-weighted regressions estimated association of EMR use with services provided, visit intensity/duration, and productivity. Marginal effects were estimated by averaging across all visits and by major reason for visit. EMR use was associated with higher probability of any examination (7.7%, 95% confidence interval [CI] = 2.4%, 13.1%); any laboratory test (5.7%, 95% CI = 2.6%, 8.8%); any health education (4.9%, 95% CI = 0.2%, 9.6%); and fewer laboratory tests (-7.1%, 95% CI = -14.2%, -0.1%). During pre/post surgery visits, EMR use was associated with 7.3% (95% CI= -12.9%, -1.8%) fewer radiology procedures. EMR use was not associated with utilization of nonmedication treatments and medications, or visit duration. During routine visits for a chronic problem, EMR use was associated with 11.2% (95% CI = 5.7%, 16.8%) more diagnostic/screening services provided per 20-minute period. EMR use had a mixed association with efficiency and productivity during office visits. EMRs may improve provider productivity, especially during visits for a new problem and routine chronic care.

  5. [Uniform analyzes of drugs in urine needed for rule of law].

    PubMed

    Hansson, Therese; Helander, Anders; Beck, Olof; Elmgren, Anders; Kugelberg, Fredrik; Kronstrand, Robert

    2015-09-22

    Drugs of abuse testing is used in various areas of society for detection and follow-up of drug use. In routine laboratory drug testing, immunoassays are employed for initial screening of specimens to indicate the presence of drugs. To confirm a positive screening test, a secondary analysis by mass spectrometry is performed. The "cut-off" is the pre-defined concentration threshold of a drug or drug metabolite above which the sample is considered positive. A reading below this level implies a negative test result. Swedish drug testing laboratories currently employ varying cut-offs to distinguish between a positive and a negative test result. Because a positive drug test may have serious legal consequences to the individual, it is of importance that testing is performed and judged equally, regardless of where it is performed. A national harmonization of cut-offs is therefore warranted. Based on data from four major Swedish drug testing laboratories, and considering the recommendations in international guidelines, a proposal for national harmonization of urine cut-offs for the most common set of drugs of abuse is presented.

  6. Preselection test of jury for improvement of olfactometric certification efficiency.

    PubMed

    Godke, Mariana Mota; Stuetz, Richard; Wang, Xinguang; Hoinaski, Leonardo; Guillot, Jean-Michel; de Melo Lisboa, Henrique

    2017-06-01

    To certificate an olfactometric jury, laboratories usually follow up the panelist screening methodology described in the European Standard EN 13725/2003. The procedure takes a lot of time, labour and money. In laboratory routine of LCQAr - Laboratory of Air Quality Control, of Federal University of Santa Catarina, Brazil, it was found that the efficiency of jury approvals used to be as low as around 30%. In order to improve the efficiency, a quick preselection test was proposed and tried for late certification recommended by EN 13725. The methodology to create the preselection test was based on the conceptions of the standards EN 13725 (CEN, 2003), ASTM 679 (2011) and ASTM 544 (2010). In the trial test, 31 volunteers participated and then screened according to the EN13725 standard. It was verified that the efficiency increased to 46% from about 30% after the introduction of the preselection test. The experiments were conducted at LCQAr, with the contribution of Water Research Centre of University of New South Wales, Australia.

  7. Continuous-flow automation and hemolysis index: a crucial combination.

    PubMed

    Lippi, Giuseppe; Plebani, Mario

    2013-04-01

    A paradigm shift has occurred in the role and organization of laboratory diagnostics over the past decades, wherein consolidation or networking of small laboratories into larger factories and point-of-care testing have simultaneously evolved and now seem to favorably coexist. There is now evidence, however, that the growing implementation of continuous-flow automation, especially in closed systems, has not eased the identification of hemolyzed specimens since the integration of preanalytical and analytical workstations would hide them from visual scrutiny, with an inherent risk that unreliable test results may be released to the stakeholders. Along with other technical breakthroughs, the new generation of laboratory instrumentation is increasingly equipped with systems that can systematically and automatically be tested for a broad series of interferences, the so-called serum indices, which also include the hemolysis index. The routine implementation of these technical tools in clinical laboratories equipped with continuous-flow automation carries several advantages and some drawbacks that are discussed in this article.

  8. Development of a multiplex serological assay reveals a worldwide distribution of murine astrovirus infections in laboratory mice.

    PubMed

    Schmidt, Katja; Butt, Julia; Mauter, Petra; Vogel, Klaus; Erles-Kemna, Andrea; Pawlita, Michael; Nicklas, Werner

    2017-01-01

    Laboratory mice play a tremendous role in biomedical research in studies on immunology, infection, cancer and therapy. In the course of standardization of mice used in animal experiments, health monitoring constitutes an important instrument towards microbiological standardization. Infections with murine astroviruses (MuAstV) were only recently discovered and are, therefore, still relatively unknown in laboratory animal science. In rodent health monitoring viral infections within a population are commonly assessed in terms of specific antibodies by serological testing, as active infection and excretion of virus is often temporary and can easily be missed. So far only ongoing infections with astroviruses can be detected by PCR. The objective of this work was the development of a sensitive and specific MuAstV multiplex serological assay with a high-throughput capability to be used in routine testing of laboratory mice. Four different MuAstV proteins were recombinantly expressed and used as antigens. The best reacting antigen, the capsid spike protein VP27, was selected and tested with a panel of 400 sera of mice from units with a known MuAstV status. Assay sensitivity and specificity resulted in 98.5% and 100%, respectively, compared to RT-PCR results. Eventually this assay was used to test 5529 serum samples in total, during routine diagnostics at the German Cancer Research Center (DKFZ) in Heidelberg between 2015 and 2017. High sero-prevalence rates of up to 98% were detected in units with open cages indicating that the virus is highly infectious and circulates within these populations virtually infecting all animals regardless of the mouse strain. In addition, data collected from 312 mice purchased from commercial breeders and from 661 mice from 58 research institutes in 15 countries worldwide allowed the conclusion that MuAstV is widespread in contemporary laboratory mouse populations.

  9. Quantitative measurement of HER2 expression in breast cancers: comparison with 'real-world' routine HER2 testing in a multicenter Collaborative Biomarker Study and correlation with overall survival.

    PubMed

    Yardley, Denise A; Kaufman, Peter A; Huang, Weidong; Krekow, Lea; Savin, Michael; Lawler, William E; Zrada, Stephen; Starr, Alexander; Einhorn, Harvey; Schwartzberg, Lee S; Adams, John W; Lie, Yolanda; Paquet, Agnes C; Sperinde, Jeff; Haddad, Mojgan; Anderson, Steve; Brigino, Marlon; Pesano, Rick; Bates, Michael P; Weidler, Jodi; Bosserman, Linda

    2015-03-18

    Accurate assessment of HER2 status is critical in determining appropriate therapy for breast cancer patients but the best HER2 testing methodology has yet to be defined. In this study, we compared quantitative HER2 expression by the HERmark™ Breast Cancer Assay (HERmark) with routine HER2 testing by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH), and correlated HER2 results with overall survival (OS) of breast cancer patients in a multicenter Collaborative Biomarker Study (CBS). Two hundred and thirty-two formalin-fixed, paraffin-embedded breast cancer tissues and local laboratory HER2 testing results were provided by 11 CBS sites. HERmark assay and central laboratory HER2 IHC retesting were retrospectively performed in a blinded fashion. HER2 results by all testing methods were obtained in 192 cases. HERmark yielded a continuum of total HER2 expression (H2T) ranging from 0.3 to 403 RF/mm2 (approximately 3 logs). The distribution of H2T levels correlated significantly (P<0.0001) with all routine HER2 testing results. The concordance of positive and negative values (equivocal cases excluded) between HERmark and routine HER2 testing was 84% for local IHC, 96% for central IHC, 85% for local FISH, and 84% for local HER2 status. OS analysis revealed a significant correlation of shorter OS with HER2 positivity by local IHC (HR=2.6, P=0.016), central IHC (HR=3.2, P=0.015), and HERmark (HR=5.1, P<0.0001) in this cohort of patients most of whom received no HER2-targeted therapy. The OS curve of discordant low (HER2 positive but H2T low, 10% of all cases) was aligned with concordant negative (HER2 negative and H2T low, HR=1.9, P=0.444), but showed a significantly longer OS than concordant positive (HER2 positive and H2T high, HR=0.31, P=0.024). Conversely, the OS curve of discordant high (HER2 negative but H2T high, 9% of all cases) was aligned with concordant positive (HR=0.41, P=0.105), but showed a significantly shorter OS than concordant negative (HR=41, P<0.0001). Quantitative HER2 measurement by HERmark is highly sensitive, accurately quantifies HER2 protein expression and correlates well with routine HER2 testing. When HERmark and local HER2 results were discordant, HERmark more accurately predicted overall survival.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chiaro, PJ

    The Environmental Effects Laboratory of the Engineering Science and Technology Division of Oak Ridge National Laboratory performed a series of tests to further evaluate and characterize the radiological response of a ''Cricket'' radiation detection system. The Cricket, manufactured by Rad/Comm Systems Corporation of Ontario, Canada, is designed to detect radioactive material that may be contained in scrap metal. The Cricket's detection unit is designed to be mounted to the base of a grappler, allowing it to monitor material while the material is being held by the grappler tines. The Cricket was tested for background stability, energy response, spherical response, surfacemore » uniformity, angular dependence, and alarm actuation. Some of these tests were repeated from a prior test of a Cricket at the Environmental Effects Laboratory as reported in ORNL/TM-2002/94. Routine environmental tests--normal temperature and relatively humidity--were also performed as part of this testing process. Overall, the Cricket performed well during the testing process. The design of the instrument and the inherent photon energy of the radionuclides had some affect on portions of the tests but do not detract from the value-added benefits of the Cricket's detection capabilities.« less

  11. Genetic antimicrobial susceptibility testing in Gram-negative sepsis - impact on time to results in a routine laboratory.

    PubMed

    Kommedal, Øyvind; Aasen, Johanne Lind; Lindemann, Paul Christoffer

    2016-07-01

    Diagnostic testing of positive blood cultures is among the most critical tasks performed by clinical microbiology laboratories, and the total analysis time from sampling to results should be kept as short as possible. By providing identification of pelleted bacteria directly from positive blood-cultures, MALDI-TOF MS opens for relatively low-complex species-adjusted genetic susceptibility testing from the same bacterial pellet. In our lab routine, we prospectively evaluated a rapid in-house real-time PCR targeting the most common aminoglycoside and cephalosporin resistance genes in Escherichia coli and Klebsiella pneumoniae and measured time to preliminary susceptibility reporting for 138 samples. The results were compared to direct phenotypic susceptibility testing with interpretation after 6 h and overnight incubation respectively. Results from the genetic susceptibility testing were available for 69.5% (96/138) of the positive blood cultures within 24 h after sample collection. No phenotypic susceptibility results were available at this time. Compared to overnight direct susceptibility testing, the average time from sample collection to preliminary susceptibility reporting was reduced with 43%, from 45 h and 5 min to 25 h and 44 min, providing an earlier adjustment of antimicrobial therapy for 12 patients. Minor logistic adjustments have the potential to save yet another 4 h. © 2016 APMIS. Published by John Wiley & Sons Ltd.

  12. Performance of potential non-crop or wild species under OECD 208 testing guideline study conditions for terrestrial non-target plants.

    PubMed

    Pallett, Ken; Cole, Jon; Oberwalder, Christian; Porch, John

    2007-02-01

    The inclusion of 52 potential non-crop or wild species in new OECD guidelines for terrestrial non-target plant (TNTP) testing led to a ring test conducted by four laboratories experienced in regulatory testing. Species selected had shown potential to meet validity criteria of emergence for TNTP studies in a previous evaluation of the 52 species. OECD 208 guideline conditions were applied, with and without seed pretreatments recommended to enhance germination. These species were Abutilon theophrasti (L.) Medic., Avena fatua L., Fallopia convolvulus (L.) Adans., Galium aparine L., Ipomoea hederacea (L.) Jacq. and Veronica persica Poir. Only I. hederacea met the validity criterion of 70% emergence in all laboratories and showed a low variability in biomass. Of the other species, none led to 70% emergence in all four laboratories. The recommended pretreatments did not have a major impact on emergence. Biomass was also investigated with A. theophrasti, A. fatua, Centaurea cyanus L., I. hederacea and Rumex crispus L. Variability of biomass, a key parameter in TNTP regulatory studies, exceeded normal biomass variability of crop species used for TNTP studies. The addition of a thin layer of quartz sand to the soil surface resulted in improved emergence of C. cyanus, G. aparine and V. persica; however, such a procedure, while routine in screening studies to improve germination, is a deviation from the TNTP guidelines. These initial studies indicate that some species could meet the emergence criteria for TNTP testing. However, there is a need for further studies on seed source, seed quality and conditions for uniform emergence before their use in routine regulatory testing.

  13. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

    PubMed Central

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-01-01

    Objective Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. Setting All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Primary and secondary outcome measures Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. Results The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. Conclusions The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. PMID:25986635

  14. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    PubMed

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  15. Laboratory practice guidelines for detecting and reporting JAK2 and MPL mutations in myeloproliferative neoplasms: a report of the Association for Molecular Pathology.

    PubMed

    Gong, Jerald Z; Cook, James R; Greiner, Timothy C; Hedvat, Cyrus; Hill, Charles E; Lim, Megan S; Longtine, Janina A; Sabath, Daniel; Wang, Y Lynn

    2013-11-01

    Recurrent mutations in JAK2 and MPL genes are genetic hallmarks of BCR-ABL1-negative myeloproliferative neoplasms. Detection of JAK2 and MPL mutations has been incorporated into routine diagnostic algorithms for these diseases. This Special Article summarizes results from a nationwide laboratory survey of JAK2 and MPL mutation analysis. Based on the current practice pattern and the literature, this Special Article provides recommendations and guidelines for laboratory practice for detection of mutations in the JAK2 and MPL genes, including clinical manifestations for prompting the mutation analysis, current and recommended methodologies for testing the mutations, and standardization for reporting the test results. This Special Article also points to future directions for genomic testing in BCR-ABL1-negative myeloproliferative neoplasms. Copyright © 2013 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  16. Diagnosis of Dengue Infection Using Conventional and Biosensor Based Techniques

    PubMed Central

    Parkash, Om; Hanim Shueb, Rafidah

    2015-01-01

    Dengue is an arthropod-borne viral disease caused by four antigenically different serotypes of dengue virus. This disease is considered as a major public health concern around the world. Currently, there is no licensed vaccine or antiviral drug available for the prevention and treatment of dengue disease. Moreover, clinical features of dengue are indistinguishable from other infectious diseases such as malaria, chikungunya, rickettsia and leptospira. Therefore, prompt and accurate laboratory diagnostic test is urgently required for disease confirmation and patient triage. The traditional diagnostic techniques for the dengue virus are viral detection in cell culture, serological testing, and RNA amplification using reverse transcriptase PCR. This paper discusses the conventional laboratory methods used for the diagnosis of dengue during the acute and convalescent phase and highlights the advantages and limitations of these routine laboratory tests. Subsequently, the biosensor based assays developed using various transducers for the detection of dengue are also reviewed. PMID:26492265

  17. Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing

    PubMed Central

    Espy, M. J.; Uhl, J. R.; Sloan, L. M.; Buckwalter, S. P.; Jones, M. F.; Vetter, E. A.; Yao, J. D. C.; Wengenack, N. L.; Rosenblatt, J. E.; Cockerill, F. R.; Smith, T. F.

    2006-01-01

    Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory. PMID:16418529

  18. Results of continuous monitoring of the performance of rubella virus IgG and hepatitis B virus surface antibody assays using trueness controls in a multicenter trial.

    PubMed

    Kruk, Tamara; Ratnam, Sam; Preiksaitis, Jutta; Lau, Allan; Hatchette, Todd; Horsman, Greg; Van Caeseele, Paul; Timmons, Brian; Tipples, Graham

    2012-10-01

    We conducted a multicenter trial in Canada to assess the value of using trueness controls (TC) for rubella virus IgG and hepatitis B virus surface antibody (anti-HBs) serology to determine test performance across laboratories over time. TC were obtained from a single source with known international units. Seven laboratories using different test systems and kit lots included the TC in routine assay runs of the analytes. TC measurements of 1,095 rubella virus IgG and 1,195 anti-HBs runs were plotted on Levey-Jennings control charts for individual laboratories and analyzed using a multirule quality control (MQC) scheme as well as a single three-standard-deviation (3-SD) rule. All rubella virus IgG TC results were "in control" in only one of the seven laboratories. Among the rest, "out-of-control" results ranged from 5.6% to 10% with an outlier at 20.3% by MQC and from 1.1% to 5.6% with an outlier at 13.4% by the 3-SD rule. All anti-HBs TC results were "in control" in only two laboratories. Among the rest, "out-of-control" results ranged from 3.3% to 7.9% with an outlier at 19.8% by MQC and from 0% to 3.3% with an outlier at 10.5% by the 3-SD rule. In conclusion, through the continuous monitoring of assay performance using TC and quality control rules, our trial detected significant intra- and interlaboratory, test system, and kit lot variations for both analytes. In most cases the assay rejections could be attributable to the laboratories rather than to kit lots. This has implications for routine diagnostic screening and clinical practice guidelines and underscores the value of using an approach as described above for continuous quality improvement in result reporting and harmonization for these analytes.

  19. The "hospital central laboratory": automation, integration and clinical usefulness.

    PubMed

    Zaninotto, Martina; Plebani, Mario

    2010-07-01

    Recent technological developments in laboratory medicine have led to a major challenge, maintaining a close connection between the search of efficiency through automation and consolidation and the assurance of effectiveness. The adoption of systems that automate most of the manual tasks characterizing routine activities has significantly improved the quality of laboratory performance; total laboratory automation being the paradigm of the idea that "human-less" robotic laboratories may allow for better operation and insuring less human errors. Furthermore, even if ongoing technological developments have considerably improved the productivity of clinical laboratories as well as reducing the turnaround time of the entire process, the value of qualified personnel remains a significant issue. Recent evidence confirms that automation allows clinical laboratories to improve analytical performances only if trained staff operate in accordance with well-defined standard operative procedures, thus assuring continuous monitoring of the analytical quality. In addition, laboratory automation may improve the appropriateness of test requests through the use of algorithms and reflex testing. This should allow the adoption of clinical and biochemical guidelines. In conclusion, in laboratory medicine, technology represents a tool for improving clinical effectiveness and patient outcomes, but it has to be managed by qualified laboratory professionals.

  20. Restructuring of international council for standardization in haematology (ICSH) in Asia.

    PubMed

    Tatsumi, N; Lewis, S M

    2002-08-01

    Standardization and harmonization in Laboratory testing are a key issue in the midst of globalization era, because most of laboratory testing has been currently achieved with various kinds of automated systems. In the developed countries, automated systems with highly-regulated principles are commonly used in the routine laboratory. However, there are so many undeveloped and developing countries in Asia that diversity of testing levels can be observed in the area. Some laboratories use glass chamber method for blood cell counting, while other laboratory use semi-automated or fully automated analyzers for complete blood count. International standardization on Hematology is focused on the developed system but not for the developing system. Established standardized documents therefore whould not be unsuitable for Asian societies. In the context, International Council for Standardization in Hematology (ICSH) changed its rules to adjust our Asian Societies and ICSH started to restructure the body. International ICSH society is divided into 5 region sub-groups. Asian area is able to possess one new sub-society, ICSH-Asia. Its reconstruction work has been just started with Asain colleagues, and we are now extending the new societies to discuss Asian problems on the quality of hematology testing.

  1. European Proficiency testing of national reference laboratories for the confirmation of sulfonamide residues in muscle and milk.

    PubMed

    Juhel-Gaugain, Murielle; Fourmond, Marie-Pierre; Delepine, Bernard; Laurentie, Michel; Brigitte, Roudaut; Sanders, Pascal

    2005-03-01

    Two interlaboratory studies were organized in 2002-2003 in order to check the proficiency of laboratories in confirming the presence of sulfonamide residues in muscle and milk. These studies involved 25 EU National Reference Laboratories (NRLs) from 21 different European Countries in charge of statutory monitoring of antimicrobial residues in food of animal origin at a national level. The study was conducted according to international and national guidelines by the Community Reference Laboratory (CRL) in charge of antimicrobial substances. Four different test matrices of sheep muscle and four different test matrices of bovine milk containing different sulfonamide substances were prepared and sent to the participants. Each participant was asked to use his own routine confirmatory method and to analyse each sample in triplicate within a period of about six weeks during which the stability of the materials was checked by the organizer. The sulfonamide content of each material was determined by calculating the robust means of all the results and the deviation of the results from the assigned values was assessed by calculating Z-scores. Overall, results were satisfactory, particularly considering that it was the first proficiency test dealing with sulfonamides organised by the Community Reference Laboratory.

  2. [Serological diagnosis of whooping cough using immunoblot methods].

    PubMed

    Lochman, I; Pokorná, L; Mertová, H

    2017-01-01

    The aim of this study was to challenge the conclusion presented in the current recommendations of the EU Perstrain Group (European group of reference laboratories) [17] that immunoblotting methods are not appropriate serological methods for the diagnosis of pertussis because their results cannot be quantified. To consider benefits of these methods for the diagnosis of Bordetella infections was another aim of this work. The residual sera from routine testing intended for disposal and results of routine tests for Bordetella infections performed in Spadia Lab in 2015 and 2016 were used in this study. The test samples were anonymized. Standard commercial ELISA and immunoblot kits were used for analyses. Using the TestLine Clinical Diagnostics Company kits, we have shown that, contrary to the conclusion of the EU Perstrain Group, quantification of the immunoblot results is possible and that these methods can improve the diagnosis of Bordetella infections, ultimately making it more effective.

  3. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  4. Interlaboratory comparability, bias, and precision for four laboratories measuring analytes in wet deposition, October 1983-December 1984

    USGS Publications Warehouse

    Brooks, Myron H.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1987-01-01

    Four laboratories involved in the routine analysis of wet-deposition samples participated in an interlaboratory comparison program managed by the U.S. Geological Survey. The four participants were: Illinois State Water Survey central analytical laboratory in Champaign, Illinois; U.S. Geological Survey national water-quality laboratories in Atlanta, Georgia, and Denver, Colorado; and Inland Waters Directorate national water-quality laboratory in Burlington, Ontario, Canada. Analyses of interlaboratory samples performed by the four laboratories from October 1983 through December 1984 were compared.Participating laboratories analyzed three types of interlaboratory samples--natural wet deposition, simulated wet deposition, and deionized water--for pH and specific conductance, and for dissolved calcium, magnesium, sodium, sodium, potassium, chloride, sulfate, nitrate, ammonium, and orthophosphate. Natural wet-deposition samples were aliquots of actual wet-deposition samples. Analyses of these samples by the four laboratories were compared using analysis of variance. Test results indicated that pH, calcium, nitrate, and ammonium results were not directly comparable among the four laboratories. Statistically significant differences between laboratory results probably only were meaningful for analyses of dissolved calcium. Simulated wet-deposition samples with known analyte concentrations were used to test each laboratory for analyte bias. Laboratory analyses of calcium, magnesium, sodium, potassium, chloride, sulfate, and nitrate were not significantly different from the known concentrations of these analytes when tested using analysis of variance. Deionized-water samples were used to test each laboratory for reporting of false positive values. The Illinois State Water Survey Laboratory reported the smallest percentage of false positive values for most analytes. Analyte precision was estimated for each laboratory from results of replicate measurements. In general, the Illinois State Water Survey laboratory achieved the greatest precision, whereas the U.S. Geological Survey laboratories achieved the least precision.

  5. A UK NEQAS ICC and ISH multicentre study using the Kreatech Poseidon HER2 FISH probe: intersite variation can be rigorously controlled using FISH.

    PubMed

    Bartlett, John M S; Campbell, Fiona M; Ibrahim, Merdol; Thomas, Jeremy; Wencyk, Pete; Ellis, Ian; Kay, Elaine; Connolly, Yvonne; O'Grady, Anthony; Barnett, Sarah; Starczynski, Jane; Cunningham, Paul; Miller, Keith

    2010-02-01

    To assess a new HER2 fluorescence in situ hybridization (FISH) test and report on multicentre intrasite and intersite variation. HER2 results were scored from 45 breast cancers in eight laboratories using the Kreatech Poseidon HER2 FISH probe (Kreatech Diagnostics, Amsterdam, the Netherlands). Overall, 80.9% of cores were successfully analysed. Mean intrasite variation for HER2 ratio assessment was low (4.74%). Intersite variation in ratio was in line with previous reports (11.9+/-0.8%) for both reference and non-reference laboratories; only one laboratory displayed significantly higher intersite variation (P=0.009) than the remaining seven laboratories. The overall incidence of misclassification of cores was <1.3%, demonstrating an excellent level of concordance (>98.7%) across all eight laboratories, irrespective of whether they were 'reference' or 'routine diagnostic' laboratories. The Kreatech Poseidon HER2 FISH test is robust and reproducible. Highly quantitatively reproducible FISH results were obtained from eight 'diagnostic' and 'reference' laboratories; however, continued quality assessments are essential to good performance.

  6. The LSLE echocardiograph - Commercial hardware aboard Spacelab. [Life Sciences Laboratory Equipment

    NASA Technical Reports Server (NTRS)

    Schwarz, R.

    1983-01-01

    The Life Sciences Laboratory Equipment Echocardiograph, a commercial 77020AC Ultrasound Imaging System modified to meet NASA's spacecraft standards, is described. The assembly consists of four models: display and control, scanner, scan converter, and physioamplifiers. Four separate processors communicate over an IEE-488 bus, and the system has more than 6000 individual components on 35 printed circuit cards. Three levels of self test are provided: a short test during power up, a basic test initiated by a front panel switch, and interactive tests for specific routines. Default mode operation further enhances reliability. Modifications of the original system include the replacement of ac power supplies with dc to dc converters, a slide-out keyboard (to prevent accidental operation), Teflon insulated wire, and additional shielding for the ultrasound transducer cable.

  7. The Value of Routine Biochemical Tests in Discriminating Between Malignant and Benign Pancreatic Tumours

    PubMed Central

    Blind, P-J; Eriksson, S.

    1991-01-01

    The probability that routine hematological laboratory tests of liver and pancreatic function can discriminate between malignant and benign pancreatic tumours, incidentally detected during operation, was investigated. The records of 53 patients with a verified diagnosis of pancreatic carcinoma and 19 patients with chronic pancreatitis were reviewed with regard to preoperative total bilirubin, direct reacting bilirubin, alkaline phosphatase, glutamyltranspeptidase, aminotransferases, lactic dehydrogenase and amylase. Multivariate and discriminant analysis were performed to calculate the predictive value for cancer, using SYSTAT statistical package in a Macintosh II computer. Total and direct reacting bilirubin and glutamyltranspeptidase were significantly higher in patients with pancreatic carcinoma. However, only considerably increased levels of direct reating bilirubin were predictive of pancreatic carcinoma. PMID:1931781

  8. Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry in Clinical Microbiology: What Are the Current Issues?

    PubMed

    van Belkum, Alex; Welker, Martin; Pincus, David; Charrier, Jean Philippe; Girard, Victoria

    2017-11-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has revolutionized the identification of microbial species in clinical microbiology laboratories. MALDI-TOF-MS has swiftly become the new gold-standard method owing to its key advantages of simplicity and robustness. However, as with all new methods, adoption of the MALDI-TOF MS approach is still not widespread. Optimal sample preparation has not yet been achieved for several applications, and there are continuing discussions on the need for improved database quality and the inclusion of additional microbial species. New applications such as in the field of antimicrobial susceptibility testing have been proposed but not yet translated to the level of ease and reproducibility that one should expect in routine diagnostic systems. Finally, during routine identification testing, unexpected results are regularly obtained, and the best methods for transmitting these results into clinical care are still evolving. We here discuss the success of MALDI-TOF MS in clinical microbiology and highlight fields of application that are still amenable to improvement. © The Korean Society for Laboratory Medicine.

  9. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  10. [Development of molecular detection of food-borne pathogenic bacteria using miniaturized microfluidic devices].

    PubMed

    Iván, Kristóf; Maráz, Anna

    2015-12-20

    Detection and identification of food-borne pathogenic bacteria are key points for the assurance of microbiological food safety. Traditional culture-based methods are more and more replaced by or supplemented with nucleic acid based molecular techniques, targeting specific (preferably virulence) genes in the genomes. Internationally validated DNA amplification - most frequently real-time polymerase chain reaction - methods are applied by the food microbiological testing laboratories for routine analysis, which will result not only in shortening the time for results but they also improve the performance characteristics (e.g. sensitivity, specificity) of the methods. Beside numerous advantages of the polymerase chain reaction based techniques for routine microbiological analysis certain drawbacks have to be mentioned, such as the high cost of the equipment and reagents, as well as the risk of contamination of the laboratory environment by the polymerase chain reaction amplicons, which require construction of an isolated laboratory system. Lab-on-a-chip systems can integrate most of these laboratory processes within a miniaturized device that delivers the same specificity and reliability as the standard protocols. The benefits of miniaturized devices are: simple - often automated - use, small overall size, portability, sterility due to single use possibility. These miniaturized rapid diagnostic tests are being researched and developed at the best research centers around the globe implementing various sample preparation and molecular DNA amplification methods on-chip. In parallel, the aim of the authors' research is to develop microfluidic Lab-on-a-chip devices for the detection and identification of food-borne pathogenic bacteria.

  11. External quality assurance of HER2 fluorescence in situ hybridisation testing: results of a UK NEQAS pilot scheme.

    PubMed

    Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith

    2007-07-01

    Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over-express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the "real world".

  12. Prospective, observational study comparing automated and visual point-of-care urinalysis in general practice

    PubMed Central

    van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier

    2016-01-01

    Objective Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. Setting The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Primary and secondary outcome measures Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Results Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Conclusions Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results. PMID:27503860

  13. Prospective, observational study comparing automated and visual point-of-care urinalysis in general practice.

    PubMed

    van Delft, Sanne; Goedhart, Annelijn; Spigt, Mark; van Pinxteren, Bart; de Wit, Niek; Hopstaken, Rogier

    2016-08-08

    Point-of-care testing (POCT) urinalysis might reduce errors in (subjective) reading, registration and communication of test results, and might also improve diagnostic outcome and optimise patient management. Evidence is lacking. In the present study, we have studied the analytical performance of automated urinalysis and visual urinalysis compared with a reference standard in routine general practice. The study was performed in six general practitioner (GP) group practices in the Netherlands. Automated urinalysis was compared with visual urinalysis in these practices. Reference testing was performed in a primary care laboratory (Saltro, Utrecht, The Netherlands). Analytical performance of automated and visual urinalysis compared with the reference laboratory method was the primary outcome measure, analysed by calculating sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) and Cohen's κ coefficient for agreement. Secondary outcome measure was the user-friendliness of the POCT analyser. Automated urinalysis by experienced and routinely trained practice assistants in general practice performs as good as visual urinalysis for nitrite, leucocytes and erythrocytes. Agreement for nitrite is high for automated and visual urinalysis. κ's are 0.824 and 0.803 (ranked as very good and good, respectively). Agreement with the central laboratory reference standard for automated and visual urinalysis for leucocytes is rather poor (0.256 for POCT and 0.197 for visual, respectively, ranked as fair and poor). κ's for erythrocytes are higher: 0.517 (automated) and 0.416 (visual), both ranked as moderate. The Urisys 1100 analyser was easy to use and considered to be not prone to flaws. Automated urinalysis performed as good as traditional visual urinalysis on reading of nitrite, leucocytes and erythrocytes in routine general practice. Implementation of automated urinalysis in general practice is justified as automation is expected to reduce human errors in patient identification and transcribing of results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  14. Stability of 35 biochemical and immunological routine tests after 10 hours storage and transport of human whole blood at 21°C.

    PubMed

    Henriksen, Linda O; Faber, Nina R; Moller, Mette F; Nexo, Ebba; Hansen, Annebirthe B

    2014-10-01

    Suitable procedures for transport of blood samples from general practitioners to hospital laboratories are requested. Here we explore routine testing on samples stored and transported as whole blood in lithium-heparin or serum tubes. Blood samples were collected from 106 hospitalized patients, and analyzed on Architect c8000 or Advia Centaur XP for 35 analytes at base line, and after storage and transport of whole blood in lithium-heparin or serum tubes at 21 ± 1°C for 10 h. Bias and imprecision (representing variation from analysis and storage) were calculated from values at baseline and after storage, and differences tested by paired t-tests. Results were compared to goals set by the laboratory. We observed no statistically significant bias and results within the goal for imprecision between baseline samples and 10-h samples for albumin, alkaline phosphatase, antitrypsin, bilirubin, creatinine, free triiodothyronine, γ-glutamyl transferase, haptoglobin, immunoglobulin G, lactate dehydrogenase, prostate specific antigen, total carbon dioxide, and urea. Alanine aminotransferase, amylase, C-reactive protein, calcium, cholesterol, creatine kinase, ferritin, free thyroxine, immunoglobulin A, immunoglobulin M, orosomucoid, sodium, transferrin, and triglycerides met goals for imprecision, though they showed a minor, but statistically significant bias in results after storage. Cobalamin, folate, HDL-cholesterol, iron, phosphate, potassium, thyroid stimulating hormone and urate warranted concern, but only folate and phosphate showed deviations of clinical importance. We conclude that whole blood in lithium-heparin or serum tubes stored for 10 h at 21 ± 1°C, may be used for routine analysis without restrictions for all investigated analytes but folate and phosphate.

  15. Concordance in diagnostic testing for respiratory pathogens of bighorn sheep

    USGS Publications Warehouse

    Walsh, Daniel P.; Cassirer, E. Frances; Bonds, Michael D.; Brown, Daniel R.; Edwards, William H.; Weiser, Glen C.; Drew, Mark L.; Briggs, Robert E.; Fox, Karen A.; Miller, Michael W.; Shanthalingam, Sudarvili; Srikumaran, Subramaniam; Besser, Thomas E.

    2016-01-01

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack of appropriate standardized commercial kits. Results of diagnostic testing may also be called into question when investigators report different etiologies for disease outbreaks, despite similar clinical and pathologic findings. To evaluate reliability of diagnostic testing for respiratory pathogens of bighorn sheep (Ovis canadensis), we conducted a series of ring tests across 6 laboratories routinely involved in detection of Mycoplasma ovipneumoniae, Pasteurellaceae, lktA (the Pasteurellaceae gene encoding leukotoxin), and 3 reference laboratories. Consistency of results for replicate samples within laboratories was high (median agreement = 1.0). Agreement between laboratories was high for polymerase chain reaction (PCR) detection of M. ovipneumoniae and culture isolation of Mannheimia spp. and Bibersteinia trehalosi(median agreement = 0.89–0.95, Kappa = 0.65–0.74), and lower for PCR detection of Mannheimiaspp. lktA (median agreement = 0.58, Kappa = 0.12). Most errors on defined status samples were false negatives, suggesting test sensitivity was a greater problem than specificity. However, tests for M. haemolytica and lktA yielded some false positive results. Despite differences in testing protocols, median agreement among laboratories and correct classification of controls for most agents was ≥0.80, meeting or exceeding the standard required by federal proficiency testing programs. This information is valuable for interpreting test results, laboratory quality assessments, and advancing diagnosis of respiratory disease in wild sheep. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  16. [My hybrid carrier of clinical pathologist].

    PubMed

    Honda, Takayuki

    2011-03-01

    In this review, I showed a brief summary of my carrier in multiple special fields (clinical pathologist, anatomical pathologist of lung, respiratory physician and infection control doctor), my studies and my own view of laboratory medicine. We chiefly study pathology of the lung, especially about type II pneumocytes. Type II pneumocytes had abundant surface coat on the apical surface containing a specific carbohydrate structure of Thomsen-Friedenreich (TF) antigen. TF antigen is a marker of type II pneumocytes beyond animal species, and can be used for evaluating activity of various interstitial pneumonia as type II pneumocyte index (number/lmm alveolar length). Three dimensional views generated from thick sections of ordinary processed paraffin blocks showed new information of normal and abnormal lung morphology. Type II pneumocytes linearly located along the elastic fibers forming framework of polygonal alveoli, and in usual interstitial pneumonia, destruction of these elastic fibers were observed. In Japan, roles of a clinical pathologist are not definite as a radiologist, and clinical laboratory in a hospital is recognized as a section only performing blood and chemical tests. Evaluation of the data and participation in diagnosis were not requested. In future, medical doctors devote themselves to treat patients, and clinical pathologists and laboratory technicians have to help the doctors in diagnostic process. Routine tests (blood and urine) are most frequently performed in clinical medicine, but the data are not adequately used. Therefore, a system is necessary for interpreting routine tests and reporting them to other medical staffs.

  17. Characterisation of STEC and other diarrheic E. coli isolated on CHROMagar™STEC at a tertiary referral hospital, Cape Town.

    PubMed

    Kalule, John Bosco; Keddy, Karen H; Nicol, Mark P

    2018-06-08

    Shiga toxin producing E. coli (STEC) is an emerging zoonotic pathogen that can cause acute renal failure, especially in children. Clinical microbiology laboratories may fail to detect STEC and other diarrhoeic E. coli unless purposive rigorous screening procedures are followed using appropriate diagnostic technology; CHROMagar™STEC has rarely been used for isolation of African diarrhoeic E. coli hence characteristics of isolates on this medium are not yet fully understood. This study aimed to determine the prevalence and characteristics of STEC and other diarrhoeic E. coli isolated on CHROMagar™STEC from stool samples submitted to the microbiology laboratory of a South African public sector tertiary care hospital. In total, 733 stool samples were tested. Of these, 4.5% (33/733) possessed diarrhoeic E. coli. Of the diarrheic E. coli, 5/33 (15.2%) were STEC, 15/33 (45.5%) EAggEC, 6/33 (18.2%) atypical EPEC, 5/33 (15.2%) typical EPEC, and 1/33 (3%) DAEC. None of the STEC isolates had been identified by routine testing (based on using sorbitol media to test for E. coli O157: H7 strains and not the other STEC) in the laboratory. Of the 33 strains, 55% (95% CI = 40.8-72.7) showed resistance to ampicillin. CHROMagar™STEC enabled detection of tellurite - resistant diarrhoeic E. coli that would be missed using routine methods. Further studies are needed to determine the proportion and characteristics of those which might have been missed using this approach.

  18. First round of external quality assessment of dengue diagnostics in the WHO Western Pacific Region, 2013.

    PubMed

    Pok, Kwoon Yong; Squires, Raynal C; Tan, Li Kiang; Takasaki, Tomohiko; Abubakar, Sazaly; Hasebe, Futoshi; Partridge, Jeffrey; Lee, Chin Kei; Lo, Janice; Aaskov, John; Ng, Lee Ching; Konings, Frank

    2015-01-01

    Accurate laboratory testing is a critical component of dengue surveillance and control. The objective of this programme was to assess dengue diagnostic proficiency among national-level public health laboratories in the World Health Organization (WHO) Western Pacific Region. Nineteen national-level public health laboratories performed routine dengue diagnostic assays on a proficiency testing panel consisting of two modules: one containing commercial serum samples spiked with cultured dengue viruses for the detection of nucleic acid and non-structural protein 1 (NS1) (Module A) and one containing human serum samples for the detection of anti-dengue virus antibodies (Module B). A review of logistics arrangements was also conducted. All 16 laboratories testing Module A performed reverse transcriptase polymerase chain reaction (RT-PCR) for both RNA and serotype detection. Of these, 15 had correct results for RNA detection and all 16 correctly serotyped the viruses. All nine laboratories performing NS1 antigen detection obtained the correct results. Sixteen of the 18 laboratories using IgM assays in Module B obtained the correct results as did the 13 laboratories that performed IgG assays. Detection of ongoing/recent dengue virus infection by both molecular (RT-PCR) and serological methods (IgM) was available in 15/19 participating laboratories. This first round of external quality assessment of dengue diagnostics was successfully conducted in national-level public health laboratories in the WHO Western Pacific Region, revealing good proficiency in both molecular and serological testing. Further comprehensive diagnostic testing for dengue virus and other priority pathogens in the Region will be assessed during future rounds.

  19. Exponential error reduction in pretransfusion testing with automation.

    PubMed

    South, Susan F; Casina, Tony S; Li, Lily

    2012-08-01

    Protecting the safety of blood transfusion is the top priority of transfusion service laboratories. Pretransfusion testing is a critical element of the entire transfusion process to enhance vein-to-vein safety. Human error associated with manual pretransfusion testing is a cause of transfusion-related mortality and morbidity and most human errors can be eliminated by automated systems. However, the uptake of automation in transfusion services has been slow and many transfusion service laboratories around the world still use manual blood group and antibody screen (G&S) methods. The goal of this study was to compare error potentials of commonly used manual (e.g., tiles and tubes) versus automated (e.g., ID-GelStation and AutoVue Innova) G&S methods. Routine G&S processes in seven transfusion service laboratories (four with manual and three with automated G&S methods) were analyzed using failure modes and effects analysis to evaluate the corresponding error potentials of each method. Manual methods contained a higher number of process steps ranging from 22 to 39, while automated G&S methods only contained six to eight steps. Corresponding to the number of the process steps that required human interactions, the risk priority number (RPN) of the manual methods ranged from 5304 to 10,976. In contrast, the RPN of the automated methods was between 129 and 436 and also demonstrated a 90% to 98% reduction of the defect opportunities in routine G&S testing. This study provided quantitative evidence on how automation could transform pretransfusion testing processes by dramatically reducing error potentials and thus would improve the safety of blood transfusion. © 2012 American Association of Blood Banks.

  20. Environmental characterisation of coal mine waste rock in the field: an example from New Zealand

    NASA Astrophysics Data System (ADS)

    Hughes, J.; Craw, D.; Peake, B.; Lindsay, P.; Weber, P.

    2007-08-01

    Characterisation of mine waste rock with respect to acid generation potential is a necessary part of routine mine operations, so that environmentally benign waste rock stacks can be constructed for permanent storage. Standard static characterisation techniques, such as acid neutralisation capacity (ANC), maximum potential acidity, and associated acid-base accounting, require laboratory tests that can be difficult to obtain rapidly at remote mine sites. We show that a combination of paste pH and a simple portable carbonate dissolution test, both techniques that can be done in the field in a 15 min time-frame, is useful for distinguishing rocks that are potentially acid-forming from those that are acid-neutralising. Use of these techniques could allow characterisation of mine wastes at the metre scale during mine excavation operations. Our application of these techniques to pyrite-bearing (total S = 1-4 wt%) but variably calcareous coal mine overburden shows that there is a strong correlation between the portable carbonate dissolution technique and laboratory-determined ANC measurements (range of 0-10 wt% calcite equivalent). Paste pH measurements on the same rocks are bimodal, with high-sulphur, low-calcite rocks yielding pH near 3 after 10 min, whereas high-ANC rocks yield paste pH of 7-8. In our coal mine example, the field tests were most effective when used in conjunction with stratigraphy. However, the same field tests have potential for routine use in any mine in which distinction of acid-generating rocks from acid-neutralising rocks is required. Calibration of field-based acid-base accounting characteristics of the rocks with laboratory-based static and/or kinetic tests is still necessary.

  1. A simple screening test for the detection of metallo-β-lactamase-producing Pseudomonas aeruginosa and Acinetobacter in a tertiary care hospital.

    PubMed

    Wan Nor Amilah, W A W; Noor Izani, N J; Ng, W K; Ashraful Haq, J

    2012-12-01

    Clinical utilization of carbapenems remains under threat with the emergence of acquired carbapenemase-producing bacteria, particularly metallo-β-lactamases (MBL). Rapid detection of MBL-producing Gram-negative bacilli is essential to prevent their widespread dissemination. However, no standardized detection method is available for routine laboratory use. The purpose of the study was to evaluate a chelating-agent based double disk synergic test and disk potentiation test for MBL-producing strain detection and to determine the isolation rate of MBL-producing Pseudomonas aeruginosa and Acinetobacter from clinical samples in our tertiary teaching hospital. A total of 22 and 66 imipenem-resistant P. aeruginosa and Acinetobacter isolates respectively were tested with ceftazidime (CAZ) disk by modified double disk synergic test and disk potentiation test using ethylenediaminetetraacetic acid (EDTA) and 2-mercaptopropionic acid (as chelating agents) to detect MBL production. The tests were compared with EDTA-phenanthroline-imipenem (EPI) microdilution MIC test as gold standard. MBL positive strains were detected in 17 (77.3%) P. aeruginosa and 2 (3.5%) Acinetobacter isolates. The disk potentiation test with 2-mercaptopropionic acid (2-MPA) dilution of 1:12 provided the most acceptable sensitivities and specificities (88.2% sensitivity and 100% specificity in P. aeruginosa; 100% sensitivity and specificity in Acinetobacter) compared to other screening methods used in this study. This study provided useful information on the local prevalence of MBL-producing P. aeruginosa and Acinetobacter in our hospital. Disc potentiation test with CAZ/2-MPA disc appears to be reliable and convenient MBL detection method in the routine clinical laboratory.

  2. Harmonization in laboratory medicine: Requests, samples, measurements and reports.

    PubMed

    Plebani, Mario

    2016-01-01

    In laboratory medicine, the terms "standardization" and "harmonization" are frequently used interchangeably as the final goal is the same: the equivalence of measurement results among different routine measurement procedures over time and space according to defined analytical and clinical quality specifications. However, the terms define two distinct, albeit closely linked, concepts based on traceability principles. The word "standardization" is used when results for a measurement are equivalent and traceable to the International System of Units (SI) through a high-order primary reference material and/or a reference measurement procedure (RMP). "Harmonization" is generally used when results are equivalent, but neither a high-order primary reference material nor a reference measurement procedure is available. Harmonization is a fundamental aspect of quality in laboratory medicine as its ultimate goal is to improve patient outcomes through the provision of accurate and actionable laboratory information. Patients, clinicians and other healthcare professionals assume that clinical laboratory tests performed by different laboratories at different times on the same sample and specimen can be compared, and that results can be reliably and consistently interpreted. Unfortunately, this is not necessarily the case, because many laboratory test results are still highly variable and poorly standardized and harmonized. Although the initial focus was mainly on harmonizing and standardizing analytical processes and methods, the scope of harmonization now also includes all other aspects of the total testing process (TTP), such as terminology and units, report formats, reference intervals and decision limits as well as tests and test profiles, requests and criteria for interpretation. Several projects and initiatives aiming to improve standardization and harmonization in the testing process are now underway. Laboratory professionals should therefore step up their efforts to provide interchangeable and comparable laboratory information in order to ultimately assure better diagnosis and treatment in patient care.

  3. Variations in pretransfusion practices.

    PubMed

    Padget, B J; Hannon, J L

    2003-01-01

    A variety of pretransfusion tests have been developed to improve the safety and effectiveness of transfusion. Recently, a number of traditional tests have been shown to offer limited clinical benefit and have been eliminated in many facilities. A survey of pretransfusion test practices was distributed to 116 hospital transfusion services. Routine test practices and facility size were analyzed. Ninety-one responses were received. Many smaller laboratories include tests such as anti-A,B, an autocontrol, and DAT, and immediate spin and 37 degrees Celsius microscopic readings. Nine percent never perform an Rh control with anti-D typing on patient samples. Various antibody screening and crossmatch methods are utilized. Individual laboratory test practices should be periodically assessed to ensure that they comply with standards, represent the recognized best practice, and are cost-effective. The survey responses indicate that many laboratories perform tests that are not necessary or cost-effective. These facilities should review their processes to determine which tests contribute to transfusion safety. Smaller facilities may be reluctant to change or lack the expertise necessary for this decision making and often continue to perform tests that have been eliminated in larger facilities. Consultation with larger hospital transfusion services may provide guidance for this change.

  4. Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Combined Species Identification and Drug Sensitivity Testing in Mycobacteria.

    PubMed

    Ceyssens, Pieter-Jan; Soetaert, Karine; Timke, Markus; Van den Bossche, An; Sparbier, Katrin; De Cremer, Koen; Kostrzewa, Markus; Hendrickx, Marijke; Mathys, Vanessa

    2017-02-01

    Species identification and drug susceptibility testing (DST) of mycobacteria are important yet complex processes traditionally reserved for reference laboratories. Recent technical improvements in matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has started to facilitate routine mycobacterial identifications in clinical laboratories. In this paper, we investigate the possibility of performing phenotypic MALDI-based DST in mycobacteriology using the recently described MALDI Biotyper antibiotic susceptibility test rapid assay (MBT-ASTRA). We randomly selected 72 clinical Mycobacterium tuberculosis and nontuberculous mycobacterial (NTM) strains, subjected them to MBT-ASTRA methodology, and compared its results to current gold-standard methods. Drug susceptibility was tested for rifampin, isoniazid, linezolid, and ethambutol (M. tuberculosis, n = 39), and clarithromycin and rifabutin (NTM, n = 33). Combined species identification was performed using the Biotyper Mycobacteria Library 4.0. Mycobacterium-specific MBT-ASTRA parameters were derived (calculation window, m/z 5,000 to 13,000, area under the curve [AUC] of >0.015, relative growth [RG] of <0.5; see the text for details). Using these settings, MBT-ASTRA analyses returned 175/177 M. tuberculosis and 65/66 NTM drug resistance profiles which corresponded to standard testing results. Turnaround times were not significantly different in M. tuberculosis testing, but the MBT-ASTRA method delivered on average a week faster than routine DST in NTM. Databases searches returned 90.4% correct species-level identifications, which increased to 98.6% when score thresholds were lowered to 1.65. In conclusion, the MBT-ASTRA technology holds promise to facilitate and fasten mycobacterial DST and to combine it directly with high-confidence species-level identifications. Given the ease of interpretation, its application in NTM typing might be the first in finding its way to current diagnostic workflows. However, further validations and automation are required before routine implementation can be envisioned. Copyright © 2017 American Society for Microbiology.

  5. 42 CFR 457.520 - Cost sharing for well-baby and well-child care services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Adolescents.” (3) Laboratory tests associated with the well-baby and well-child routine physical examinations... 42 Public Health 4 2010-10-01 2010-10-01 false Cost sharing for well-baby and well-child care... well-baby and well-child care services. (a) A State may not impose copayments, deductibles, coinsurance...

  6. Hair sheep blood, citrated or defibrinated, fulfills all requirements of blood agar for diagnostic microbiology laboratory tests.

    PubMed

    Yeh, Ellen; Pinsky, Benjamin A; Banaei, Niaz; Baron, Ellen Jo

    2009-07-03

    Blood agar is used for the identification and antibiotic susceptibility testing of many bacterial pathogens. In the developing world, microbiologists use human blood agar because of the high cost and inhospitable conditions for raising wool sheep or horses to supply blood. Many pathogens either fail to grow entirely or exhibit morphologies and hemolytic patterns on human blood agar that confound colony recognition. Furthermore, human blood can be hazardous to handle due to HIV and hepatitis. This study investigated whether blood from hair sheep, a hardy, low-maintenance variety of sheep adapted for hot climates, was suitable for routine clinical microbiology studies. Hair sheep blood obtained by jugular venipuncture was anticoagulated by either manual defibrination or collection in human blood bank bags containing citrate-phosphate-dextrose. Trypticase soy 5% blood agar was made from both forms of hair sheep blood and commercial defibrinated wool sheep blood. Growth characteristics, colony morphologies, and hemolytic patterns of selected human pathogens, including several streptococcal species, were evaluated. Specialized identification tests, including CAMP test, reverse CAMP test, and satellite colony formation with Haemophilus influenzae and Abiotrophia defectiva were also performed. Mueller-Hinton blood agar plates prepared from the three blood types were compared in antibiotic susceptibility tests by disk diffusion and E-test. The results of all studies showed that blood agar prepared from citrated hair sheep blood is suitable for microbiological tests used in routine identification and susceptibility profiling of human pathogens. The validation of citrated hair sheep blood eliminates the labor-intensive and equipment-requiring process of manual defibrination. Use of hair sheep blood, in lieu of human blood currently used by many developing world laboratories and as an alternative to cost-prohibitive commercial sheep blood, offers the opportunity to dramatically improve the safety and accuracy of laboratory diagnosis of pathogenic bacteria in resource-poor countries.

  7. Effects of two types of medical contrast media on routine chemistry results by three automated chemistry analyzers.

    PubMed

    Park, Yu Jin; Rim, John Hoon; Yim, Jisook; Lee, Sang-Guk; Kim, Jeong-Ho

    2017-08-01

    The use of iodinated contrast media has grown in popularity in the past two decades, but relatively little attention has been paid to the possible interferential effects of contrast media on laboratory test results. Herein, we investigate medical contrast media interference with routine chemistry results obtained by three automated chemistry analyzers. Ten levels of pooled serum were used in the study. Two types of medical contrast media [Iopamiro (iopamidol) and Omnipaque (iohexol)] were evaluated. To evaluate the dose-dependent effects of the contrast media, iopamidol and iohexol were spiked separately into aliquots of serum for final concentrations of 1.8%, 3.6%, 5.5%, 7.3%, and 9.1%. The 28 analytes included in the routine chemistry panel were measured by using Hitachi 7600, AU5800, and Cobas c702 analyzers. We calculated the delta percentage difference (DPD) between the samples and the control, and examined dose-dependent trends. When the mean DPD values were compared with the reference cut-off criteria, the only uniformly interferential effect observed for all analyzers was in total protein with iopamidol. Two additional analytes that showed trends toward interferential effects only in few analyzers and exceeded the limits of the allowable error were the serum iron and the total CO 2 . The other combinations of analyzer and contrast showed no consistent dose-dependent propensity for change in any analyte level. Our study suggests that many of the analytes included in routine chemistry results, except total protein and serum iron, are not significantly affected by iopamidol and iohexol. These results suggest that it would be beneficial to apply a flexible medical evaluation process for patients requiring both laboratory tests and imaging studies, minimizing the need for strict regulations for sequential tests. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  8. An audit of the laboratory diagnosis of cryptosporidiosis in England and Wales.

    PubMed

    Chalmers, Rachel M; Atchison, Christina; Barlow, Katrina; Young, Yvonne; Roche, Anita; Manuel, Rohini

    2015-07-01

    To assess the level of practice consistent with UK national standards for Cryptosporidium testing, an audit was performed of 156 publicly funded clinical microbiology laboratories in England and Wales between August 2013 and April 2014. Responses were received from 85 (54 %) laboratories. First line diagnostic methods used were mainly microscopy with modified Ziehl-Neelsen (mZN) or auramine phenol (AP) staining (68/85, 80 %), enzyme immunoassays (EIAs) (16/85, 19 %) or in-house PCR (1/85, 1 %). The use of EIAs was more widespread than reported previously. Various methods were used for confirmation of positive EIA reactions and laboratories frequently resorted to sending samples to the national reference laboratory for this purpose, indicating that guidance is required for performance monitoring and confirmation of positive reactions. Laboratory positivity rates were related to the diagnostic test used, with highest median rates reported by those using PCR, EIAs or AP microscopy, and the lowest by those using mZN microscopy. One-third of responding laboratories (28/85, 33 %) routinely tested all stools for Cryptosporidium. However, 16 (19 %) laboratories used stool consistency to decide whether to test for this parasite. Other selection criteria included patient age (n = 18; 21 % laboratories), history or clinical details (n = 40; 47 %), duration of hospitalization (n = 18; 21 %) or clinician requests (n = 25; 29 %). To encourage laboratories to test all stools submitted for the investigation of diarrhoeal illness for Cryptosporidium, revision of the guidance in the national standards is under way. This will enable improved assessment of the burden of illness and ability to monitor outbreaks, and measure changes in reported cases.

  9. Accuracy of the HumaSensplus point-of-care uric acid meter using capillary blood obtained by fingertip puncture.

    PubMed

    Fabre, Stéphanie; Clerson, Pierre; Launay, Jean-Marie; Gautier, Jean-François; Vidal-Trecan, Tiphaine; Riveline, Jean-Pierre; Platt, Adam; Abrahamsson, Anna; Miner, Jeffrey N; Hughes, Glen; Richette, Pascal; Bardin, Thomas

    2018-05-02

    The uric acid (UA) level in patients with gout is a key factor in disease management and is typically measured in the laboratory using plasma samples obtained after venous puncture. This study aimed to assess the reliability of immediate UA measurement with capillary blood samples obtained by fingertip puncture with the HumaSens plus point-of-care meter. UA levels were measured using both the HumaSens plus meter in the clinic and the routine plasma UA method in the biochemistry laboratory of 238 consenting diabetic patients. HumaSens plus capillary and routine plasma UA measurements were compared by linear regression, Bland-Altman plots, intraclass correlation coefficient (ICC), and Lin's concordance coefficient. Values outside the dynamic range of the meter, low (LO) or high (HI), were analyzed separately. The best capillary UA thresholds for detecting hyperuricemia were determined by receiver operating characteristic (ROC) curves. The impact of potential confounding factors (demographic and biological parameters/treatments) was assessed. Capillary and routine plasma UA levels were compared to reference plasma UA measurements by liquid chromatography-mass spectrometry (LC-MS) for a subgroup of 67 patients. In total, 205 patients had capillary and routine plasma UA measurements available. ICC was 0.90 (95% confidence interval (CI) 0.87-0.92), Lin's coefficient was 0.91 (0.88-0.93), and the Bland-Altman plot showed good agreement over all tested values. Overall, 17 patients showed values outside the dynamic range. LO values were concordant with plasma values, but HI values were considered uninterpretable. Capillary UA thresholds of 299 and 340 μmol/l gave the best results for detecting hyperuricemia (corresponding to routine plasma UA thresholds of 300 and 360 μmol/l, respectively). No significant confounding factor was found among those tested, except for hematocrit; however, this had a negligible influence on the assay reliability. When capillary and routine plasma results were discordant, comparison with LC-MS measurements showed that plasma measurements had better concordance: capillary UA, ICC 0.84 (95% CI 0.75-0.90), Lin's coefficient 0.84 (0.77-0.91); plasma UA, ICC 0.96 (0.94-0.98), Lin's coefficient 0.96 (0.94-0.98). UA measurements with the HumaSens plus meter were reasonably comparable with those of the laboratory assay. The meter is easy to use and may be useful in the clinic and in epidemiologic studies.

  10. Quality of the clinical laboratory department in a specialized hospital in Alexandria, Egypt.

    PubMed

    Elhoseeny, T A; Mohammad, E K

    2013-01-01

    Assessment and improvement of turnaround times (TAT) as well as customer satisfaction is essential for laboratory quality management. This study in a specialized hospital in Alexandria, Egypt measured the current TAT for outpatient department bilirubin samples and evaluated the satisfaction of physicians with aspects of clinical laboratory services. While the mean TAT for 110 bilirubin tests [58.1 (SD 31.8) min] was within the College of American Pathologists' benchmark, the 90th percentile was long (96.7 min); 62.7% of tests were reported within 60 min. The mean overall satisfaction score of physicians (range 1-5) was 3.46 (SD 0.49). The highest satisfaction rating was for staff courtesy while the lowest ratings were for laboratory management responsiveness, outpatient stat TAT and critical value notification. Quality or reliability of results was judged by physicians as the most important factor (32.3%), followed by routine test TAT (18.5%). Further analysis of the different steps of the TAT would be helpful and follow-up through examining outliers is recommended

  11. Application of the Toyota Production System improves core laboratory operations.

    PubMed

    Rutledge, Joe; Xu, Min; Simpson, Joanne

    2010-01-01

    To meet the increased clinical demands of our hospital expansion, improve quality, and reduce costs, our tertiary care, pediatric core laboratory used the Toyota Production System lean processing to reorganize our 24-hour, 7 d/wk core laboratory. A 4-month, consultant-driven process removed waste, led to a physical reset of the space to match the work flow, and developed a work cell for our random access analyzers. In addition, visual controls, single piece flow, standard work, and "5S" were instituted. The new design met our goals as reflected by achieving and maintaining improved turnaround time (TAT; mean for creatinine reduced from 54 to 23 minutes) with increased testing volume (20%), monetary savings (4 full-time equivalents), decreased variability in TAT, and better space utilization (25% gain). The project had the unanticipated consequence of eliminating STAT testing because our in-laboratory TAT for routine testing was less than our prior STAT turnaround goal. The viability of this approach is demonstrated by sustained gains and further PDCA (Plan, Do, Check, Act) improvements during the 4 years after completion of the project.

  12. Evaluation of Resilient Modulus of Subgrade and Base Materials in Indiana and Its Implementation in MEPDG

    PubMed Central

    Siddiki, Nayyarzia; Nantung, Tommy; Kim, Daehyeon

    2014-01-01

    In order to implement MEPDG hierarchical inputs for unbound and subgrade soil, a database containing subgrade M R, index properties, standard proctor, and laboratory M R for 140 undisturbed roadbed soil samples from six different districts in Indiana was created. The M R data were categorized in accordance with the AASHTO soil classifications and divided into several groups. Based on each group, this study develops statistical analysis and evaluation datasets to validate these models. Stress-based regression models were evaluated using a statistical tool (analysis of variance (ANOVA)) and Z-test, and pertinent material constants (k 1, k 2 and k 3) were determined for different soil types. The reasonably good correlations of material constants along with M R with routine soil properties were established. Furthermore, FWD tests were conducted on several Indiana highways in different seasons, and laboratory resilient modulus tests were performed on the subgrade soils that were collected from the falling weight deflectometer (FWD) test sites. A comparison was made of the resilient moduli obtained from the laboratory resilient modulus tests with those from the FWD tests. Correlations between the laboratory resilient modulus and the FWD modulus were developed and are discussed in this paper. PMID:24701162

  13. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    PubMed

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn screening laboratories. The recommended practices address the benefits of using a quality management system approach, factors to consider before introducing new tests, establishment and verification of test performance specifications, the total laboratory testing process (which consists of the preanalytic, analytic, and postanalytic phases), confidentiality of patient information and test results, and personnel qualifications and responsibilities for laboratory testing for inherited metabolic diseases. These recommendations are intended for laboratories that perform biochemical genetic testing to improve the quality of laboratory services and for newborn screening laboratories to ensure the quality of laboratory practices for inherited metabolic disorders. These recommendations also are intended as a resource for medical and public health professionals who evaluate laboratory practices, for users of laboratory services to facilitate their collaboration with newborn screening systems and use of biochemical genetic tests, and for standard-setting organizations and professional societies in developing future laboratory quality standards and practice recommendations. This report complements Good Laboratory Practices for Molecular Genetic Testing for Heritable Diseases and Conditions (CDC. Good laboratory practices for molecular genetic testing for heritable diseases and conditions. MMWR 2009;58 [No. RR-6]) to provide guidance for ensuring and improving the quality of genetic laboratory services and public health outcomes. Future recommendations for additional areas of genetic testing will be considered on the basis of continued monitoring and evaluation of laboratory practices, technology advancements, and the development of laboratory standards and guidelines.

  14. Updating the immunology curriculum in clinical laboratory science.

    PubMed

    Stevens, C D

    2000-01-01

    To determine essential content areas of immunology/serology courses at the clinical laboratory technician (CLT) and clinical laboratory scientist (CLS) levels. A questionnaire was designed which listed all major topics in immunology and serology. Participants were asked to place a check beside each topic covered. For an additional list of serological and immunological laboratory testing, participants were asked to indicate if each test was performed in either the didactic or clinical setting, or not performed at all. A national survey of 593 NAACLS approved CLT and CLS programs was conducted by mail under the auspices of ASCLS. Responses were obtained from 158 programs. Respondents from all across the United States included 60 CLT programs, 48 hospital-based CLS programs, 45 university-based CLS programs, and 5 university-based combined CLT and CLS programs. The survey was designed to enumerate major topics included in immunology and serology courses by a majority of participants at two distinct educational levels, CLT and CLS. Laboratory testing routinely performed in student laboratories as well as in the clinical setting was also determined for these two levels of practitioners. Certain key topics were common to most immunology and serology courses. There were some notable differences in the depth of courses at the CLT and CLS levels. Laboratory testing associated with these courses also differed at the two levels. Testing requiring more detailed interpretation, such as antinuclear antibody patterns (ANAs), was mainly performed by CLS students only. There are certain key topics as well as specific laboratory tests that should be included in immunology/serology courses at each of the two different educational levels to best prepare students for the workplace. Educators can use this information as a guide to plan a curriculum for such courses.

  15. Overuse of preoperative laboratory coagulation testing and ABO blood typing: a French national study.

    PubMed

    Beloeil, H; Ruchard, D; Drewniak, N; Molliex, S

    2017-12-01

    Following publication of guidelines on routine preoperative tests, the French Society of Anaesthesiology and Intensive Care (SFAR), in association with French national public health insurance, conducted a survey to evaluate adherence to guidelines and the economic consequences. Using the French Hospital Discharge Database and National Health Insurance Information system, tests performed during the 30 days before surgery were analysed for two situations: (1) standard laboratory coagulation tests and ABO blood typing in children able to walk and scheduled for tonsillectomy/adenoidectomy; and (2) ABO blood typing in adults before laparoscopic cholecystectomy, thyroidectomy, lumbar discectomy or breast surgery. Guidelines do not recommend any preoperative tests in these settings. Between 2013 and 2015, a coagulation test was performed in 49% of the 241 017 children who underwent tonsillectomy and 39% of the 133 790 children who underwent adenoidectomy. A similar pattern was observed for ABO blood typing although re-operation rates for bleeding on the first postoperative day were very low (0.12-0.31% for tonsillectomy and 0.01-0.02% for adenoidectomy). Between 2012 and 2015, ABO blood typing was performed in 32-45% of the 1 114 082 patients who underwent one of the four selected procedures. The transfusion rate was very low (0.02-0.31%). The mean cost for the four procedures over the 4 yr period was €5 310 000 (sd €325 000). Standard laboratory coagulation tests and ABO blood typing are still routinely prescribed before surgery and anaesthesia despite current guidelines. This over-prescription represents a high and unnecessary cost, and should therefore be addressed. © The Author 2017. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  16. Performance and Cost Efficiency of KRAS Mutation Testing for Metastatic Colorectal Cancer in Routine Diagnosis: The MOKAECM Study, a Nationwide Experience

    PubMed Central

    Chatellier, Gilles; Côté, Jean-François; Pages, Jean-Christophe; de Fraipont, Florence; Boyer, Jean-Christophe; Merlio, Jean Philippe; Morel, Alain; Gorisse, Marie-Claude; de Cremoux, Patricia; Leroy, Karen; Milano, Gérard; Ouafik, L’Houcine; Merlin, Jean-Louis; Le Corre, Delphine; Aucouturier, Pascaline; Sabourin, Jean-Christophe; Nowak, Frédérique; Frebourg, Thierry; Emile, Jean-François; Durand-Zaleski, Isabelle; Laurent-Puig, Pierre

    2013-01-01

    Purpose Rapid advances in the understanding of cancer biology have transformed drug development thus leading to the approval of targeted therapies and to the development of molecular tests to select patients that will respond to treatments. KRAS status has emerged as a negative predictor of clinical benefit from anti-EGFR antibodies in colorectal cancer, and anti-EGFR antibodies use was limited to KRAS wild type tumors. In order to ensure wide access to tumor molecular profiling, the French National Cancer Institute (INCa) has set up a national network of 28 regional molecular genetics centers. Concurrently, a nationwide external quality assessment for KRAS testing (MOKAECM) was granted to analyze reproducibility and costs. Methods 96 cell-line DNAs and 24 DNA samples from paraffin embedded tumor tissues were sent to 40 French laboratories. A total of 5448 KRAS results were collected and analyzed and a micro-costing study was performed on sites for 5 common methods by an independent team of health economists. Results This work provided a baseline picture of the accuracy and reliability of KRAS analysis in routine testing conditions at a nationwide level. Inter-laboratory Kappa values were >0.8 for KRAS results despite differences detection methods and the use of in-house technologies. Specificity was excellent with only one false positive in 1128 FFPE data, and sensitivity was higher for targeted techniques as compared to Sanger sequencing based methods that were dependent upon local expertise. Estimated reagent costs per patient ranged from €5.5 to €19.0. Conclusion The INCa has set-up a network of public laboratories dedicated to molecular oncology tests. Our results showed almost perfect agreements in KRAS testing at a nationwide level despite different testing methods ensuring a cost-effective equal access to personalized colorectal cancer treatment. PMID:23935912

  17. Performance and cost efficiency of KRAS mutation testing for metastatic colorectal cancer in routine diagnosis: the MOKAECM study, a nationwide experience.

    PubMed

    Blons, Hélène; Rouleau, Etienne; Charrier, Nathanaël; Chatellier, Gilles; Côté, Jean-François; Pages, Jean-Christophe; de Fraipont, Florence; Boyer, Jean-Christophe; Merlio, Jean Philippe; Morel, Alain; Gorisse, Marie-Claude; de Cremoux, Patricia; Leroy, Karen; Milano, Gérard; Ouafik, L'houcine; Merlin, Jean-Louis; Le Corre, Delphine; Aucouturier, Pascaline; Sabourin, Jean-Christophe; Nowak, Frédérique; Frebourg, Thierry; Emile, Jean-François; Durand-Zaleski, Isabelle; Laurent-Puig, Pierre

    2013-01-01

    Rapid advances in the understanding of cancer biology have transformed drug development thus leading to the approval of targeted therapies and to the development of molecular tests to select patients that will respond to treatments. KRAS status has emerged as a negative predictor of clinical benefit from anti-EGFR antibodies in colorectal cancer, and anti-EGFR antibodies use was limited to KRAS wild type tumors. In order to ensure wide access to tumor molecular profiling, the French National Cancer Institute (INCa) has set up a national network of 28 regional molecular genetics centers. Concurrently, a nationwide external quality assessment for KRAS testing (MOKAECM) was granted to analyze reproducibility and costs. 96 cell-line DNAs and 24 DNA samples from paraffin embedded tumor tissues were sent to 40 French laboratories. A total of 5448 KRAS results were collected and analyzed and a micro-costing study was performed on sites for 5 common methods by an independent team of health economists. This work provided a baseline picture of the accuracy and reliability of KRAS analysis in routine testing conditions at a nationwide level. Inter-laboratory Kappa values were >0.8 for KRAS results despite differences detection methods and the use of in-house technologies. Specificity was excellent with only one false positive in 1128 FFPE data, and sensitivity was higher for targeted techniques as compared to Sanger sequencing based methods that were dependent upon local expertise. Estimated reagent costs per patient ranged from €5.5 to €19.0. The INCa has set-up a network of public laboratories dedicated to molecular oncology tests. Our results showed almost perfect agreements in KRAS testing at a nationwide level despite different testing methods ensuring a cost-effective equal access to personalized colorectal cancer treatment.

  18. Toxicity and bioaccumulation of sediment-associated contaminants using freshwater invertebrates: A review of methods and applications

    USGS Publications Warehouse

    Ingersoll, C.G.; Ankley, G.T.; Benoit, D.A.; Brunson, E.L.; Burton, G.A.; Dwyer, F.J.; Hoke, R.A.; Landrum, P.F.; Norberg-King, T. J.; Winger, P.V.

    1995-01-01

    This paper reviews recent developments in methods for evaluating the toxicity and bioaccumulation of contaminants associated with freshwater sediments and summarizes example case studies demonstrating the application of these methods. Over the past decade, research has emphasized development of more specific testing procedures for conducting 10-d toxicity tests with the amphipod Hyalella azteca and the midge Chironomus tentans. Toxicity endpoints measured in these tests are survival for H. azteca and survival and growth for C. tentans. Guidance has also been developed for conducting 28-d bioaccumulation tests with the oligochaete Lumbriculus variegatus, including determination of bioaccumulation kinetics for different compound classes. These methods have been applied to a variety of sediments to address issues ranging from site assessments to bioavailability of organic and inorganic contaminants using field-collected and laboratory-spiked samples. Survival and growth of controls routinely meet or exceed test acceptability criteria. Results of laboratory bioaccumulation studies with L. variegatus have been confirmed with comparisons to residues (PCBs, PAHs, DDT) present from synoptically collected field populations of oligochaetes. Additional method development is currently underway to develop chronic toxicity tests and to provide additional data-confirming responses observed in laboratory sediment tests with natural benthic populations.

  19. Preanalytical influence of pneumatic tube delivery system on results of routine biochemistry and haematology analysis.

    PubMed

    Petit, Morgane; Mine, Louis; Pascreau, Tiffany; Brouzes, Chantal; Majoux, Sandrine; Borgel, Delphine; Beaudeux, Jean-Louis; Lasne, Dominique; Hennequin, Carole

    2017-12-01

    Pneumatic tube delivery system (PTS) enables to reduce considerably turnaround times. The aim of the study was to assess the influence of the PTS on the quality of routine biochemical and hematological tests in our laboratory. Blood samples from 6 hospitalized patients and 8 healthy volunteers were analyzed. Blood samples were delivered to the laboratory by a PTS and by a human courier. We performed the following analysis: ionized calcium, sodium, potassium, lactate deshydrogenase (LDH), aspartate aminotransferase (ASAT), arterial blood gas, complete blood count and coagulation test as prothrombin time, activated partial thromboplastin time, factors V and VIII. Results were compared between the both method of transport according to the recommendation of the Société française de biologie clinique and the French committee for accreditation (SH-GTA01, norme NF ISO 5275-6). The hemolysis index of plasma was similar between the groups and no morphological differences were found on blood cells. For three samples, when delivered by PTS, LDH levels (two samples) and neutrophil polynuclear count (one sample) were above the recommended guidelines compared to those delivered by courier. Conversely, LDH levels and FVIII were below in two samples delivered by PTS. LDH levels, PNN count or factor VIII can be affected by PTS without the clinical interpretation being modified. We concluded that the PTS can be used to transport blood samples for routine biochemical and hematological analysis in our hospital.

  20. The impact of commercial rapid respiratory virus diagnostic tests on patient outcomes and health system utilization.

    PubMed

    Ko, Fiona; Drews, Steven J

    2017-10-01

    Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.

  1. Contamination with HIV antibody may be responsible for false positive results in specimens tested on automated platforms running HIV 4th generation assays in a region of high HIV prevalence.

    PubMed

    Hardie, Diana Ruth; Korsman, Stephen N; Hsiao, Nei-Yuan; Morobadi, Molefi Daniel; Vawda, Sabeehah; Goedhals, Dominique

    2017-01-01

    In South Africa where the prevalence of HIV infection is very high, 4th generation HIV antibody/p24 antigen combo immunoassays are the tests of choice for laboratory based screening. Testing is usually performed in clinical pathology laboratories on automated analysers. To investigate the cause of false positive results on 4th generation HIV testing platforms in public sector laboratories, the performance of two automated platforms was compared in a clinical pathology setting, firstly on routine diagnostic specimens and secondly on known sero-negative samples. Firstly, 1181 routine diagnostic specimens were sequentially tested on Siemens and Roche automated 4th generation platforms. HIV viral load, western blot and follow up testing were used to determine the true status of inconclusive specimens. Subsequently, known HIV seronegative samples from a single donor were repeatedly tested on both platforms and an analyser was tested for surface contamination with HIV positive serum to identify how suspected specimen contamination could be occurring. Serial testing of diagnostic specimens yielded 163 weakly positive or discordant results. Only 3 of 163 were conclusively shown to indicate true HIV infection. Specimen contamination with HIV antibody was suspected, based on the following evidence: the proportion of positive specimens increased on repeated passage through the analysers; viral loads were low or undetectable and western blots negative or indeterminate on problem specimens; screen negative, 2nd test positive specimens tested positive when reanalysed on the screening assay; follow up specimens (where available) were negative. Similarly, an increasing number of known negative specimens became (repeatedly) sero-positive on serial passage through one of the analysers. Internal and external analyser surfaces were contaminated with HIV serum, evidence that sample splashes occur during testing. Due to the extreme sensitivity of these assays, contamination with minute amounts of HIV antibody can cause a negative sample to test positive. Better contamination control measures are needed on analysers used in clinical pathology environments, especially in regions where HIV sero-prevalence is high.

  2. Impact of routine real-time PCR testing of imported malaria over 4 years of implementation in a clinical laboratory.

    PubMed

    Shokoples, Sandra; Mukhi, Shamir N; Scott, Allison N; Yanow, Stephanie K

    2013-06-01

    In clinical laboratories, diagnosis of imported malaria is commonly performed by microscopy. However, the volume of specimens is generally low and maintaining proficiency in reading blood smears, particularly at the species level, is challenging in this setting. To address this problem, the Provincial Laboratory for Public Health (ProvLab) in Alberta, Canada, implemented real-time PCR for routine confirmation of all smear-positive samples in the province. Here we report our experience over a 4-year period (2008 to 2012) with this new diagnostic algorithm. While detection of Plasmodium falciparum by microscopy alone was accurate, real-time PCR served as an important adjunct to microscopy for the identification of non-falciparum species. In 18% of cases, the result was reported as non-falciparum or the species could not be identified by microscopy alone, and in all cases, the species was resolved by real-time PCR. In another 4% of cases, the species was misidentified by microscopy. To enhance surveillance for malaria, we integrated our demographic, clinical, and laboratory data into a new system developed by the Canadian Network for Public Health Intelligence, called the Malaria System for Online Surveillance (SOS). Using this application, we characterized our patient populations and travel history to identify risk factors associated with malaria infection abroad.

  3. External quality assurance of HER2 fluorescence in situ hybridisation testing: results of a UK NEQAS pilot scheme

    PubMed Central

    Bartlett, John M S; Ibrahim, Merdol; Jasani, Bharat; Morgan, John M; Ellis, Ian; Kay, Elaine; Magee, Hilary; Barnett, Sarah; Miller, Keith

    2007-01-01

    Background and Aims Trastuzumab provides clinical benefit for advanced and early breast cancer patients whose tumours over‐express or have gene amplification of the HER2 oncogene. The UK National External Quality Assessment Scheme (NEQAS) for immunohistochemical testing was established to assess and improve the quality of HER2 immunohistochemical testing. However, until recently, no provision was available for HER2 fluorescence in situ hybridisation (FISH) testing. A pilot scheme was set up to review the performance of FISH testing in clinical diagnostic laboratories. Methods FISH was performed in 6 reference and 31 participating laboratories using a cell line panel with known HER2 status. Results Using results from reference laboratories as a criterion for acceptable performance, 60% of all results returned by participants were appropriate and 78% either appropriate or acceptable. However, 22.4% of results returned were deemed inappropriate, including 13 cases (4.2%) where a misdiagnosis would have been made had these been clinical specimens. Conclusions The results of three consecutive runs show that both reference laboratories and a proportion of routine clinical diagnostic (about 25%) centres can consistently achieve acceptable quality control of HER2 testing. Data from a significant proportion of participating laboratories show that further steps are required, including those taken via review of performance under schemes such as NEQAS, to improve quality of HER2 testing by FISH in the “real world”. PMID:16963466

  4. Bioactive contaminants leach from disposable laboratory plasticware.

    PubMed

    McDonald, G Reid; Hudson, Alan L; Dunn, Susan M J; You, Haitao; Baker, Glen B; Whittal, Randy M; Martin, Jonathan W; Jha, Amitabh; Edmondson, Dale E; Holt, Andrew

    2008-11-07

    Disposable plasticware such as test tubes, pipette tips, and multiwell assay or culture plates are used routinely in most biological research laboratories. Manufacturing of plastics requires the inclusion of numerous chemicals to enhance stability, durability, and performance. Some lubricating (slip) agents, exemplified by oleamide, also occur endogenously in humans and are biologically active, and cationic biocides are included to prevent bacterial colonization of the plastic surface. We demonstrate that these manufacturing agents leach from laboratory plasticware into a standard aqueous buffer, dimethyl sulfoxide, and methanol and can have profound effects on proteins and thus on results from bioassays of protein function. These findings have far-reaching implications for the use of disposable plasticware in biological research.

  5. An international standardization programme towards the application of gene expression profiling in routine leukaemia diagnostics: the Microarray Innovations in LEukemia study prephase

    PubMed Central

    Kohlmann, Alexander; Kipps, Thomas J; Rassenti, Laura Z; Downing, James R; Shurtleff, Sheila A; Mills, Ken I; Gilkes, Amanda F; Hofmann, Wolf-Karsten; Basso, Giuseppe; Dell’Orto, Marta Campo; Foà, Robin; Chiaretti, Sabina; De Vos, John; Rauhut, Sonja; Papenhausen, Peter R; Hernández, Jesus M; Lumbreras, Eva; Yeoh, Allen E; Koay, Evelyn S; Li, Rachel; Liu, Wei-min; Williams, Paul M; Wieczorek, Lothar; Haferlach, Torsten

    2008-01-01

    Gene expression profiling has the potential to enhance current methods for the diagnosis of haematological malignancies. Here, we present data on 204 analyses from an international standardization programme that was conducted in 11 laboratories as a prephase to the Microarray Innovations in LEukemia (MILE) study. Each laboratory prepared two cell line samples, together with three replicate leukaemia patient lysates in two distinct stages: (i) a 5-d course of protocol training, and (ii) independent proficiency testing. Unsupervised, supervised, and r2 correlation analyses demonstrated that microarray analysis can be performed with remarkably high intra-laboratory reproducibility and with comparable quality and reliability. PMID:18573112

  6. Quality-assurance results for routine water analysis in US Geological Survey laboratories, water year 1991

    USGS Publications Warehouse

    Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.

    1994-01-01

    The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and phosphorus. A negative or positive bias condition was indicated in three of five nutrient constituents. There was acceptable precision and no indication of bias for the 14 low ionic-strength analytical procedures tested in the National Water Quality Laboratory program and for the 32 inorganic and 5 nutrient analytical procedures tested in the Quality of Water Service Unit during water year 1991.

  7. Monitoring and investigating natural disease by veterinary pathologists in diagnostic laboratories.

    PubMed

    O'Toole, D

    2010-01-01

    Many emerging diseases in animals are initially recognized by diagnostic pathologists in animal health laboratories using routine laboratory submissions, in conjunction with clinical veterinarians and wildlife biologists. Familiar recent examples are chronic wasting disease, bovine spongiform encephalopathy, West Nile encephalomyelitis in North America, and postweaning multisystemic wasting syndrome in pigs. The recognition of new diseases in animals requires that the curiosity of diagnosticians be articulated with the capacity of animal health laboratories to create effective diagnostic teams, solicit additional cases from the field at minimal cost to clients, and develop relationships with basic researchers. Bovine neosporosis is used as an example to illustrate how a disease investigation triggered by routine clinical accessions can have international ramifications. Between the late 1980s and 1995, diagnosticians with California's animal health laboratory system identified neosporosis as a cause of reproductive wastage in cattle, characterized the lesions, isolated the agent, defined routes of transmission, met Koch's postulates, and developed diagnostic assays. Diagnostic pathologists catalyzed the process. The neosporosis investigation in California suggests useful attributes of veterinary diagnostic laboratories that pursue emerging diseases identified through routine laboratory accessions.

  8. Evaluation of the Abbott RealTime HCV assay for quantitative detection of hepatitis C virus RNA.

    PubMed

    Michelin, Birgit D A; Muller, Zsofia; Stelzl, Evelyn; Marth, Egon; Kessler, Harald H

    2007-02-01

    The Abbott RealTime HCV assay for quantitative detection of HCV RNA has recently been introduced. In this study, the performance of the Abbott RealTime HCV assay was evaluated and compared to the COBAS AmpliPrep/COBAS TaqMan HCV test. Accuracy, linearity, interassay and intra-assay variations were determined, and a total of 243 routine clinical samples were investigated. When accuracy of the new assay was tested, the majority of results were found to be within +/-0.5 log(10) unit of the results obtained by reference laboratories. Determination of linearity resulted in a quasilinear curve up to 1.0 x 10(6)IU/ml. The interassay variation ranged from 15% to 32%, and the intra-assay variation ranged from 5% to 8%. When clinical samples were tested by the Abbott RealTime HCV assay and the results were compared with those obtained by the COBAS AmpliPrep/COBAS TaqMan HCV test, the results for 93% of all samples with positive results by both tests were found to be within +/-1.0 log(10) unit. The viral loads for all patients measured by the Abbott and Roche assays showed a high correlation (R(2)=0.93); quantitative results obtained by the Abbott assay were found to be lower than those obtained by the Roche assay. The Abbott RealTime HCV assay proved to be suitable for use in the routine diagnostic laboratory. The time to results was similar for both of the assays.

  9. Elevated blood lead levels in refugee children--New Hampshire, 2003-2004.

    PubMed

    2005-01-21

    As a result of reductions in lead hazards and improved screening practices, blood lead levels (BLLs) in children aged 1-5 years are decreasing in the United States. However, the risk for elevated BLLs (> or =10 microg/dL) remains high for certain populations, including refugees. After the death of a Sudanese refugee child from lead poisoning in New Hampshire in 2000, the New Hampshire Department of Health and Human Services (NHDHHS) developed lead testing guidelines to screen and monitor refugee children. These guidelines recommend 1) capillary blood lead testing for refugee children aged 6 months-15 years within 3 months after arrival in New Hampshire, 2) follow-up venous testing of children aged <6 years within 3-6 months after initial screening, and 3) notation of refugee status on laboratory slips for first tests. In 2004, routine laboratory telephone reports of elevated BLLs to the New Hampshire Childhood Lead Poisoning Prevention Program (NHCLPPP) called attention to a pattern of elevated BLLs among refugee children. To develop prevention strategies, NHDHHS analyzed NHCLPPP and Manchester Health Department (MHD) data, focusing on the 37 African refugee children with elevated BLLs on follow-up for whom complete data were available. This report describes the results of that analysis, which indicated that 1) follow-up blood lead testing is useful to identify lead exposure that occurs after resettlement and 2) refugee children in New Hampshire older than those routinely tested might have elevated BLLs. Refugee children in all states should be tested for lead poisoning on arrival and several months after initial screening to assess exposure after resettlement.

  10. Molecular diagnosis of microbial aetiologies using SepsiTest™ in the daily routine of a diagnostic laboratory.

    PubMed

    Haag, Heike; Locher, Franziska; Nolte, Oliver

    2013-08-01

    A universal PCR and sequencing test, SepsiTest™ (Molzym, Germany) was evaluated for its applicability during daily diagnostic routine in a privately operated laboratory. In total, 96 specimens originating from 66 patients under suspect of infectious endocarditis, infections of joints, encephalitis/meningitis, systemic infections and infections of unknown genesis were PCR analysed and compared to culture results. Samples comprised cultured and non-cultured blood, synovial fluid, synovial tissue, heart valves, pacemakers, spinal tissue, cerebrospinal fluid, and swabs. PCR and culture were concordant in 26 negative and 8 positive cases (51.5%). A group of 25 patients was culture-negative but PCR-positive (37.9%). In at least 14 of these, common and/or rare aetiologies were identified, while for 4 patients the results of 16S PCR could not be unequivocally linked with the underlying disease. Benefits and limitations of the molecular test are discussed with special emphasis on technical and economic issues. In conclusion, SepsiTest™ proved to be a valuable tool for the diagnosis of aetiologies, particularly in cases of culture-negative patients who are under strong suspicion for an infection. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. The Development of a Novel, Validated, Rapid and Simple Method for the Detection of Sarcocystis fayeri in Horse Meat in the Sanitary Control Setting.

    PubMed

    Furukawa, Masato; Minegishi, Yasutaka; Izumiyama, Shinji; Yagita, Kenji; Mori, Hideto; Uemura, Taku; Etoh, Yoshiki; Maeda, Eriko; Sasaki, Mari; Ichinose, Kazuya; Harada, Seiya; Kamata, Yoichi; Otagiri, Masaki; Sugita-Konishi, Yoshiko; Ohnishi, Takahiro

    2016-01-01

    Sarcocystis fayeri (S. fayeri) is a newly identified causative agent of foodborne disease that is associated with the consumption of raw horse meat. The testing methods prescribed by the Ministry of Health, Labour and Welfare of Japan are time consuming and require the use of expensive equipment and a high level of technical expertise. Accordingly, these methods are not suitable for use in the routine sanitary control setting to prevent outbreaks of foodborne disease. In order to solve these problems, we have developed a new, rapid and simple testing method using LAMP, which takes only 1 hour to perform and which does not involve the use of any expensive equipment or expert techniques. For the validation of this method, an inter-laboratory study was performed among 5 institutes using 10 samples infected with various concentrations of S. fayeri. The results of the inter-laboratory study demonstrated that our LAMP method could detect S. fayeri at concentrations greater than 10(4) copies/g. Thus, this new method could be useful in screening for S. fayeri as a routine sanitary control procedure.

  12. External quality assessment of dengue and chikungunya diagnostics in the Asia Pacific region, 2015

    PubMed Central

    Soh, Li Ting; Squires, Raynal C; Tan, Li Kiang; Pok, Kwoon Yong; Yang, HuiTing; Liew, Christina; Shah, Aparna Singh; Aaskov, John; Abubakar, Sazaly; Hasabe, Futoshi; Ng, Lee Ching

    2016-01-01

    Objective To conduct an external quality assessment (EQA) of dengue and chikungunya diagnostics among national-level public health laboratories in the Asia Pacific region following the first round of EQA for dengue diagnostics in 2013. Methods Twenty-four national-level public health laboratories performed routine diagnostic assays on a proficiency testing panel consisting of two modules. Module A contained serum samples spiked with cultured dengue virus (DENV) or chikungunya virus (CHIKV) for the detection of nucleic acid and DENV non-structural protein 1 (NS1) antigen. Module B contained human serum samples for the detection of anti-DENV antibodies. Results Among 20 laboratories testing Module A, 17 (85%) correctly detected DENV RNA by reverse transcription polymerase chain reaction (RT–PCR), 18 (90%) correctly determined serotype and 19 (95%) correctly identified CHIKV by RT–PCR. Ten of 15 (66.7%) laboratories performing NS1 antigen assays obtained the correct results. In Module B, 18/23 (78.3%) and 20/20 (100%) of laboratories correctly detected anti-DENV IgM and IgG, respectively. Detection of acute/recent DENV infection by both molecular (RT–PCR) and serological methods (IgM) was available in 19/24 (79.2%) participating laboratories. Discussion Accurate laboratory testing is a critical component of dengue and chikungunya surveillance and control. This second round of EQA reveals good proficiency in molecular and serological diagnostics of these diseases in the Asia Pacific region. Further comprehensive diagnostic testing, including testing for Zika virus, should comprise future iterations of the EQA. PMID:27508088

  13. Evaluation of Cobas Integra 800 under simulated routine conditions in six laboratories.

    PubMed

    Redondo, Francisco L; Bermudez, Pilar; Cocco, Claudio; Colella, Francesca; Graziani, Maria Stella; Fiehn, Walter; Hierla, Thomas; Lemoël, Gisèle; Belliard, AnneMarie; Manene, Dieudonne; Meziani, Mourad; Liebel, Maryann; McQueen, Matthew J; Stockmann, Wolfgang

    2003-03-01

    The new selective access analyser Cobas Integra 800 from Roche Diagnostics was evaluated in an international multicentre study at six sites. Routine simulation experiments showed good performance and full functionality of the instrument and provocation of anomalous situations generated no problems. The new features on Cobas Integra 800, namely clot detection and dispensing control, worked according to specifications. The imprecision of Cobas Integra 800 fulfilled the proposed quality specifications regarding imprecision of analytical systems for clinical chemistry with few exceptions. Claims for linearity, drift, and carry-over were all within the defined specifications, except urea linearity. Interference exists in some cases, as could be expected due to the chemistries applied. Accuracy met the proposed quality specifications, except in some special cases. Method comparisons with Cobas Integra 700 showed good agreement; comparisons with other analysis systems yielded in several cases explicable deviations. Practicability of Cobas Integra 800 met or exceeded the requirements for more than 95% of all attributes rated. The strong points of the new analysis system were reagent handling, long stability of calibration curves, high number of tests on board, compatibility of the sample carrier to other Roche systems, and the sample integrity check for more reliable analytical results. The improvement of the workflow offered by the 5-position rack and STAT handling like on Cobas Integra 800 makes the instrument attractive for further consolidation in the medium-sized laboratory, for dedicated use of special analytes, and/or as back-up in the large routine laboratory.

  14. Epidemiology of alcohol and other drug use among motor vehicle crash victims admitted to a trauma center.

    PubMed

    Walsh, J Michael; Flegel, Ron; Cangianelli, Leo A; Atkins, Randolph; Soderstrom, Carl A; Kerns, Timothy J

    2004-09-01

    The objectives of this research were to (1) determine the incidence and prevalence of alcohol and other drug use among motor vehicle crash (MVC) victims admitted to a regional Level-I trauma center, and (2) to examine the utility of using a rapid point-of-collection (POC) drug-testing device to identify MVC patients with drug involvement. Blood and urine specimens were routinely collected per clinical protocol for each MVC victim at the time of admission. Blood alcohol concentration (BAC) levels were determined per standard clinical protocol. Clinical urine specimens were routinely split so that a POC drug-testing device for the detection of commonly abused drugs (Marijuana, Cocaine, Amphetamines, Methamphetamines, and Opiates) could be compared to that of the standard hospital laboratory analysis of each urine specimen (which also included Barbiturates and Benzodiazepines). In the six-month period of this study, nearly two-thirds of trauma center admissions were victims of motor vehicle crashes. During this time, blood and urine was collected from 322 MVC victims. Toxicology results indicated that 59.3% of MVC victims tested positive for either commonly abused drugs or alcohol. More patients tested positive for drug use than tested positive for alcohol, with 33.5% testing positive for drug use only, 15.8% testing positive for alcohol use only, and 9.9% testing positive for both drugs and alcohol. Less than half (45.2%) of the substance-abusing patients in this study would have been identified by an alcohol test alone. After alcohol, marijuana and benzodiazepines were the most frequently detected drugs. Point of collection (POC) test results correlated well with laboratory results and provide important information to initiate rapid intervention/treatment for substance use problems among injured patients.

  15. Adjuncts in the IVF laboratory: where is the evidence for 'add-on' interventions?

    PubMed

    Harper, Joyce; Jackson, Emily; Sermon, Karen; Aitken, Robert John; Harbottle, Stephen; Mocanu, Edgar; Hardarson, Thorir; Mathur, Raj; Viville, Stephane; Vail, Andy; Lundin, Kersti

    2017-03-01

    Globally, IVF patients are routinely offered and charged for a selection of adjunct treatments and tests or 'add-ons' that they are told may improve their chance of a live birth, despite there being no clinical evidence supporting the efficacy of the add-on. Any new IVF technology claiming to improve live birth rates (LBR) should, in most cases, first be tested in an appropriate animal model, then in clinical trials, to ensure safety, and finally in a randomized controlled trial (RCT) to provide high-quality evidence that the procedure is safe and effective. Only then should the technique be considered as 'routine' and only when applied to the similar patient population as those studied in the RCT. Even then, further pediatric and long-term follow-up studies will need to be undertaken to examine the long-term safety of the procedure. Alarmingly, there are currently numerous examples where adjunct treatments are used in the absence of evidence-based medicine and often at an additional fee. In some cases, when RCTs have shown the technique to be ineffective, it is eventually withdrawn from the clinic. In this paper, we discuss some of the adjunct treatments currently being offered globally in IVF laboratories, including embryo glue and adherence compounds, sperm DNA fragmentation, time-lapse imaging, preimplantation genetic screening, mitochondria DNA load measurement and assisted hatching. We examine the evidence for their safety and efficacy in increasing LBRs. We conclude that robust studies are needed to confirm the safety and efficacy of any adjunct treatment or test before they are offered routinely to IVF patients. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Improving preanalytic processes using the principles of lean production (Toyota Production System).

    PubMed

    Persoon, Thomas J; Zaleski, Sue; Frerichs, Janice

    2006-01-01

    The basic technologies used in preanalytic processes for chemistry tests have been mature for a long time, and improvements in preanalytic processes have lagged behind improvements in analytic and postanalytic processes. We describe our successful efforts to improve chemistry test turnaround time from a central laboratory by improving preanalytic processes, using existing resources and the principles of lean production. Our goal is to report 80% of chemistry tests in less than 1 hour and to no longer recognize a distinction between expedited and routine testing. We used principles of lean production (the Toyota Production System) to redesign preanalytic processes. The redesigned preanalytic process has fewer steps and uses 1-piece flow to move blood samples through the accessioning, centrifugation, and aliquoting processes. Median preanalytic processing time was reduced from 29 to 19 minutes, and the laboratory met the goal of reporting 80% of chemistry results in less than 1 hour for 11 consecutive months.

  17. A review of current and future molecular diagnostic tests for use in the microbiology laboratory.

    PubMed

    Jannes, Geert; De Vos, Daniel

    2006-01-01

    Nucleic acid-based diagnostics gradually are replacing or complementing culture-based, biochemical, and immunological assays in routine microbiology laboratories. Similar to conventional tests, the first-generation deoxyribonucleic acid assays determined only a single analyte. Recent improvements in detection technologies have paved the way for the development of multiparameter assays using macroarrays or micro-arrays, while the introduction of closed-tube real-time polymerase chain reaction systems has resulted in the development of rapid microbial diagnostics with a reduced contamination risk. The use of these new molecular technologies is not restricted to detection and identification of microbial pathogens but also can be used for genotyping, allowing one to determine antibiotic resistance or to perform microbial fingerprinting.

  18. Hybrid nanosensor for colorimetric and ultrasensitive detection of nuclease contaminations

    NASA Astrophysics Data System (ADS)

    Cecere, Paola; Valentini, Paola; Pompa, Pier Paolo

    2016-04-01

    Nucleases are ubiquitous enzymes that degrade DNA or RNA, thus they can prejudice the good outcome of molecular biology experiments involving nucleic acids. We propose a colorimetric test for the naked-eye detection of nuclease contaminations. The system uses an hybrid nanosensor, based on gold nanoparticles functionalized with DNA probes. Our assay is rapid, instrument-free, simple and low-cost. Moreover, it reaches sensitivity equal or better than those of commercial kits, and presents a lot of advantageous aspects. Therefore, it is very competitive, with a real market potential. This test will be relevant in routine process monitoring in scientific laboratories, and in quality control in clinical laboratories and industrial processes, allowing the simultaneous detection of nucleases with different substrate specificities and large-scale screening.

  19. Comparison of Routine Health Management Information System Versus Enhanced Inpatient Malaria Surveillance for Estimating the Burden of Malaria Among Children Admitted to Four Hospitals in Uganda

    PubMed Central

    Mpimbaza, Arthur; Miles, Melody; Sserwanga, Asadu; Kigozi, Ruth; Wanzira, Humphrey; Rubahika, Denis; Nasr, Sussann; Kapella, Bryan K.; Yoon, Steven S.; Chang, Michelle; Yeka, Adoke; Staedke, Sarah G.; Kamya, Moses R.; Dorsey, Grant

    2015-01-01

    The primary source of malaria surveillance data in Uganda is the Health Management Information System (HMIS), which does not require laboratory confirmation of reported malaria cases. To improve data quality, an enhanced inpatient malaria surveillance system (EIMSS) was implemented with emphasis on malaria testing of all children admitted in select hospitals. Data were compared between the HMIS and the EIMSS at four hospitals over a period of 12 months. After the implementation of the EIMSS, over 96% of admitted children under 5 years of age underwent laboratory testing for malaria. The HMIS significantly overreported the proportion of children under 5 years of age admitted with malaria (average absolute difference = 19%, range = 8–27% across the four hospitals) compared with the EIMSS. To improve the quality of the HMIS data for malaria surveillance, the National Malaria Control Program should, in addition to increasing malaria testing rates, focus on linking laboratory test results to reported malaria cases. PMID:25422396

  20. Diagnosis and treatment of dementia: 2. Diagnosis

    PubMed Central

    Feldman, Howard H.; Jacova, Claudia; Robillard, Alain; Garcia, Angeles; Chow, Tiffany; Borrie, Michael; Schipper, Hyman M.; Blair, Mervin; Kertesz, Andrew; Chertkow, Howard

    2008-01-01

    Background Dementia can now be accurately diagnosed through clinical evaluation, cognitive screening, basic laboratory evaluation and structural imaging. A large number of ancillary techniques are also available to aid in diagnosis, but their role in the armamentarium of family physicians remains controversial. In this article, we provide physicians with practical guidance on the diagnosis of dementia based on recommendations from the Third Canadian Consensus Conference on the Diagnosis and Treatment of Dementia, held in March 2006. Methods We developed evidence-based guidelines using systematic literature searches, with specific criteria for study selection and quality assessment, and a clear and transparent decision-making process. We selected studies published from January 1996 to December 2005 that pertained to key diagnostic issues in dementia. We graded the strength of evidence using the criteria of the Canadian Task Force on Preventive Health Care. Results Of the 1591 articles we identified on all aspects of dementia diagnosis, 1095 met our inclusion criteria; 620 were deemed to be of good or fair quality. From a synthesis of the evidence in these studies, we made 32 recommendations related to the diagnosis of dementia. There are clinical criteria for diagnosing most forms of dementia. A standard diagnostic evaluation can be performd by family physicians over multiple visits. It involves a clinical history (from patient and caregiver), a physical examination and brief cognitive testing. A list of core laboratory tests is recommended. Structural imaging with computed tomography or magnetic resonance imaging is recommended in selected cases to rule out treatable causes of dementia or to rule in cerebrovascular disease. There is insufficient evidence to recommend routine functional imaging, measurement of biomarkers or neuropsychologic testing. Interpretation The diagnosis of dementia remains clinically integrative based on history, physical examination and brief cognitive testing. A number of core laboratory tests are also recommended. Structural neuroimaging is advised in selected cases. Other diagnostic approaches, including functional neuroimaging, neuropsychological testing and measurement of biomarkers, have shown promise but are not yet recommended for routine use by family physicians. PMID:18362376

  1. Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice.

    PubMed

    Schot, Marjolein J C; van Delft, Sanne; Kooijman-Buiting, Antoinette M J; de Wit, Niek J; Hopstaken, Rogier M

    2015-05-18

    Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. All testing procedures were performed at a diagnostic centre for primary care in the Netherlands. Urine samples were collected at four general practices. Analytical performance and agreement of the POCT analysers regarding nitrite, leucocytes and erythrocytes, with the laboratory reference standard, was the primary outcome measure, and analysed by calculating sensitivity, specificity, positive and negative predictive value, and Cohen's κ coefficient for agreement. Secondary outcome measures were the user-friendliness of the POCT analysers, in addition to other characteristics of the analysers. The following six POCT analysers were evaluated: Uryxxon Relax (Macherey Nagel), Urisys 1100 (Roche), Clinitek Status (Siemens), Aution 11 (Menarini), Aution Micro (Menarini) and Urilyzer (Analyticon). Analytical performance was good for all analysers. Compared with laboratory reference standards, overall agreement was good, but differed per parameter and per analyser. Concerning the nitrite test, the most important test for clinical practice, all but one showed perfect agreement with the laboratory standard. For leucocytes and erythrocytes specificity was high, but sensitivity was considerably lower. Agreement for leucocytes varied between good to very good, and for the erythrocyte test between fair and good. First-time users indicated that the analysers were easy to use. They expected higher productivity and accuracy when using these analysers in daily practice. The overall performance and user-friendliness of all six commercially available POCT urine analysers was sufficient to justify routine use in suspected urinary tract infections in general practice. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Revision Workshops in Elementary Mathematics Enhance Student Performance in Routine Laboratory Calculations

    ERIC Educational Resources Information Center

    Sawbridge, Jenny L.; Qureshi, Haseeb K.; Boyd, Matthew J.; Brown, Angus M.

    2014-01-01

    The ability to understand and implement calculations required for molarity and dilution computations that are routinely undertaken in the laboratory are essential skills that should be possessed by all students entering an undergraduate Life Sciences degree. However, it is increasingly recognized that the majority of these students are ill…

  3. AFNOR validation of Premi Test, a microbiological-based screening tube-test for the detection of antimicrobial residues in animal muscle tissue.

    PubMed

    Gaudin, Valerie; Juhel-Gaugain, Murielle; Morétain, Jean-Pierre; Sanders, Pascal

    2008-12-01

    Premi Test contains viable spores of a strain of Bacillus stearothermophilus which is sensitive to antimicrobial residues, such as beta-lactams, tetracyclines, macrolides and sulphonamides. The growth of the strain is inhibited by the presence of antimicrobial residues in muscle tissue samples. Premi Test was validated according to AFNOR rules (French Association for Normalisation). The AFNOR validation was based on the comparison of reference methods (French Official method, i.e. four plate test (FPT) and the STAR protocol (five plate test)) with the alternative method (Premi Test). A preliminary study was conducted in an expert laboratory (Community Reference Laboratory, CRL) on both spiked and incurred samples (field samples). Several method performance criteria (sensitivity, specificity, relative accuracy) were estimated and are discussed, in addition to detection capabilities. Adequate agreement was found between the alternative method and the reference methods. However, Premi Test was more sensitive to beta-lactams and sulphonamides than the FPT. Subsequently, a collaborative study with 11 laboratories was organised by the CRL. Blank and spiked meat juice samples were sent to participants. The expert laboratory (CRL) statistically analysed the results. It was concluded that Premi Test could be used for the routine determination of antimicrobial residues in muscle of different animal origin with acceptable analytical performance. The detection capabilities of Premi Test for beta-lactams (amoxicillin, ceftiofur), one macrolide (tylosin) and tetracycline were at the level of the respective maximum residue limits (MRL) in muscle samples or even lower.

  4. ELECTRONICS UPGRADE TO THE SAVANNAH RIVER NATIONAL LABORATORY COULOMETER FOR PLUTONIUM AND NEPTUNIUM ASSAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cordaro, J.; Holland, M.; Reeves, G.

    The Savannah River Site (SRS) has the analytical measurement capability to perform high-precision plutonium concentration measurements by controlled-potential coulometry. State-of-the-art controlled-potential coulometers were designed and fabricated by the Savannah River National Laboratory and installed in the Analytical Laboratories process control laboratory. The Analytical Laboratories uses coulometry for routine accountability measurements of and for verification of standard preparations used to calibrate other plutonium measurement systems routinely applied to process control, nuclear safety, and other accountability applications. The SRNL Coulometer has a demonstrated measurement reliability of {approx}0.05% for 10 mg samples. The system has also been applied to the characterization of neptuniummore » standard solutions with a comparable reliability. The SRNL coulometer features: a patented current integration system; continuous electrical calibration versus Faraday's Constants and Ohm's Law; the control-potential adjustment technique for enhanced application of the Nernst Equation; a wide operating room temperature range; and a fully automated instrument control and data acquisition capability. Systems have been supplied to the International Atomic Energy Agency (IAEA), Russia, Japanese Atomic Energy Agency (JAEA) and the New Brunswick Laboratory (NBL). The most recent vintage of electronics was based on early 1990's integrated circuits. Many of the components are no longer available. At the request of the IAEA and the Department of State, SRNL has completed an electronics upgrade of their controlled-potential coulometer design. Three systems have built with the new design, one for the IAEA which was installed at SAL in May 2011, one system for Los Alamos National Laboratory, (LANL) and one for the SRS Analytical Laboratory. The LANL and SRS systems are undergoing startup testing with installation scheduled for this summer.« less

  5. Roadside drug testing: An evaluation of the Alere DDS® 2 mobile test system.

    PubMed

    Rohrig, Timothy P; Moore, Christine M; Stephens, Kimberly; Cooper, Kelsey; Coulter, Cynthia; Baird, Tyson; Garnier, Margaux; Miller, Samuel; Tuyay, James; Osawa, Kei; Chou, Joshua; Nuss, Carson; Collier, Jeff; Wittman, Karen Cudlin

    2018-04-01

    The number of drivers using drugs has increased over the last few years, and is likely to continue its upward trend. Testing drivers for alcohol use is routine and standardized, but the same is not true for the identification of driving under the influence of drugs (DUID). The Drug Evaluation and Classification Program (DECP) was developed to train police officers to recognize the signs and symptoms of recent drug use and remains an invaluable program; however, there are insufficient numbers of these highly trained drug recognition experts (DREs) available to attend every potential drug involved traffic incident. While blood and urine samples are used to test for drugs in a driver, both have disadvantages, particularly as they pertain to the length of time required after a traffic stop to sample collection. Therefore, the development of oral fluid testing devices which can be operated at the roadside and have the potential to assist officers in the identification of drug use is a major advancement in DUID cases. This project evaluated the performance of one instrumental oral fluid roadside testing device (Alere DDS®2) compared to DRE opinion, oral fluid laboratory-based analysis, and routine blood testing. The results showed that there was a good correlation with DRE observations and the device performance was >80% in all drug categories compared to laboratory-based analytical testing, both in oral fluid and blood, with few exceptions. The instrument can be considered a useful tool to assist law enforcement in identifying a drugged driver. Because the device does not test for all potentially impairing drugs, the opinion of the police officer regarding the condition of the driver should still be considered the most important aspect for arrest and further action. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Rapid Radiochemical Methods for Asphalt Paving Material ...

    EPA Pesticide Factsheets

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  7. Internal Medicine Resident Engagement with a Laboratory Utilization Dashboard: Mixed Methods Study.

    PubMed

    Kurtzman, Gregory; Dine, Jessica; Epstein, Andrew; Gitelman, Yevgenly; Leri, Damien; Patel, Miltesh S; Ryskina, Kyra

    2017-09-01

    The objective of this study was to measure internal medicine resident engagement with an electronic medical record-based dashboard providing feedback on their use of routine laboratory tests relative to service averages. From January 2016 to June 2016, residents were e-mailed a snapshot of their personalized dashboard, a link to the online dashboard, and text summarizing the resident and service utilization averages. We measured resident engagement using e-mail read-receipts and web-based tracking. We also conducted 3 hour-long focus groups with residents. Using grounded theory approach, the transcripts were analyzed for common themes focusing on barriers and facilitators of dashboard use. Among 80 residents, 74% opened the e-mail containing a link to the dashboard and 21% accessed the dashboard itself. We did not observe a statistically significant difference in routine laboratory ordering by dashboard use, although residents who opened the link to the dashboard ordered 0.26 fewer labs per doctor-patient-day than those who did not (95% confidence interval, -0.77 to 0.25; = 0 .31). While they raised several concerns, focus group participants had positive attitudes toward receiving individualized feedback delivered in real time. © 2017 Society of Hospital Medicine.

  8. Evidence and resources to implement Pharmacogenetic Knowledge for Precision Medicine

    PubMed Central

    Caudle, Kelly E.; Gammal, Roseann S.; Whirl-Carrillo, Michelle; Hoffman, James M.; Relling, Mary V.; Klein, Teri E.

    2016-01-01

    Purpose Implementation of pharmacogenetics into clinical practice has been relatively slow despite substantial scientific progress over the last decade. One barrier that inhibits uptake of pharmacogenetics into routine clinical practice is the lack of knowledge of how to translate a genetic test into a clinical action based on current evidence. The purpose of this paper is to describe the current state of pharmacogenetic evidence and evidence-based resources that facilitate the uptake of pharmacogenetics into clinical practice. Summary Controversy exists over the required evidence threshold needed for routine clinical implementation of pharmacogenetics. Large randomized controlled trials are not clinically feasible or necessary for many pharmacogenetic applications. Online resources exist like the Clinical Pharmacogenetics Implementation Consortium (CPIC) and the Pharmacogenomics Knowledgebase (PharmGKB) that provide freely available, evidence-based resources that facilitate the translation of genetic laboratory test results into actionable prescribing recommendations for specific drugs. Conclusion Resources provided by organizations such as CPIC and PharmGKB that use standardized approaches to evaluate the literature and provide clinical guidance are essential for the implementation of pharmacogenetics into routine clinical practice. PMID:27864205

  9. Bio-repository of post-clinical test samples at the national cancer center hospital (NCCH) in Tokyo.

    PubMed

    Furuta, Koh; Yokozawa, Karin; Takada, Takako; Kato, Hoichi

    2009-08-01

    We established the Bio-repository at the National Cancer Center Hospital in October 2002. The main purpose of this article is to show the importance and usefulness of a bio-repository of post-clinical test samples not only for translational cancer research but also for routine clinical oncology by introducing the experience of setting up such a facility. Our basic concept of a post-clinical test sample is not as left-over waste, but rather as frozen evidence of a patient's pathological condition at a particular point. We can decode, if not all, most of the laboratory data from a post-clinical test sample. As a result, the bio-repository is able to provide not only the samples, but potentially all related laboratory data upon request. The areas of sample coverage are the following: sera after routine blood tests; sera after cross-match tests for transfusion; serum or plasma submitted at a patient's clinically important time period by the physician; and samples collected by the individual investigator. The formats of stored samples are plasma or serum, dried blood spot (DBS) and buffy coat. So far, 150 218 plasmas or sera, 35 253 DBS and 536 buffy coats have been registered for our bio-repository system. We arranged to provide samples to various concerned parties under strict legal and ethical agreements. Although the number of the utilized samples was initially limited, the inquiries for sample utilization are now increasing steadily from both research and clinical sources. Further efforts to increase the benefits of the repository are intended.

  10. Recognition of military-specific physical activities with body-fixed sensors.

    PubMed

    Wyss, Thomas; Mäder, Urs

    2010-11-01

    The purpose of this study was to develop and validate an algorithm for recognizing military-specific, physically demanding activities using body-fixed sensors. To develop the algorithm, the first group of study participants (n = 15) wore body-fixed sensors capable of measuring acceleration, step frequency, and heart rate while completing six military-specific activities: walking, marching with backpack, lifting and lowering loads, lifting and carrying loads, digging, and running. The accuracy of the algorithm was tested in these isolated activities in a laboratory setting (n = 18) and in the context of daily military training routine (n = 24). The overall recognition rates during isolated activities and during daily military routine activities were 87.5% and 85.5%, respectively. We conclude that the algorithm adequately recognized six military-specific physical activities based on sensor data alone both in a laboratory setting and in the military training environment. By recognizing type of physical activities this objective method provides additional information on military-job descriptions.

  11. Standardization of fixation, processing and staining methods for the central nervous system of vertebrates.

    PubMed

    Aldana Marcos, H J; Ferrari, C C; Benitez, I; Affanni, J M

    1996-12-01

    This paper reports the standardization of methods used for processing and embedding various vertebrate brains of different size in paraffin. Other technical details developed for avoiding frequent difficulties arising during laboratory routine are also reported. Some modifications of the Nissl and Klüver-Barrera staining methods are proposed. These modifications include: 1) a Nissl stain solution with a rapid and efficient action with easier differentiation; 2) the use of a cheap microwave oven for the Klüver-Barrera stain. These procedures have the advantage of permitting Nissl and Klüver-Barrera staining of nervous tissue in about five and fifteen minutes respectively. The proposed procedures have been tested in brains obtained from fish, amphibians, reptiles and mammals of different body sizes. They are the result of our long experience in preparing slides for comparative studies. Serial sections of excellent quality were regularly obtained in all the specimens studied. These standardized methods, being simple and quick, are recommended for routine use in neurobiological laboratories.

  12. Automated Broad-Range Molecular Detection of Bacteria in Clinical Samples

    PubMed Central

    Hoogewerf, Martine; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.

    2016-01-01

    Molecular detection methods, such as quantitative PCR (qPCR), have found their way into clinical microbiology laboratories for the detection of an array of pathogens. Most routinely used methods, however, are directed at specific species. Thus, anything that is not explicitly searched for will be missed. This greatly limits the flexibility and universal application of these techniques. We investigated the application of a rapid universal bacterial molecular identification method, IS-pro, to routine patient samples received in a clinical microbiology laboratory. IS-pro is a eubacterial technique based on the detection and categorization of 16S-23S rRNA gene interspace regions with lengths that are specific for each microbial species. As this is an open technique, clinicians do not need to decide in advance what to look for. We compared routine culture to IS-pro using 66 samples sent in for routine bacterial diagnostic testing. The samples were obtained from patients with infections in normally sterile sites (without a resident microbiota). The results were identical in 20 (30%) samples, IS-pro detected more bacterial species than culture in 31 (47%) samples, and five of the 10 culture-negative samples were positive with IS-pro. The case histories of the five patients from whom these culture-negative/IS-pro-positive samples were obtained suggest that the IS-pro findings are highly clinically relevant. Our findings indicate that an open molecular approach, such as IS-pro, may have a high added value for clinical practice. PMID:26763956

  13. Prospective evaluation of the VITEK MS for the routine identification of bacteria and yeast in the clinical microbiology laboratory: assessment of accuracy of identification and turnaround time.

    PubMed

    Charnot-Katsikas, Angella; Tesic, Vera; Boonlayangoor, Sue; Bethel, Cindy; Frank, Karen M

    2014-02-01

    This study assessed the accuracy of bacterial and yeast identification using the VITEK MS, and the time to reporting of isolates before and after its implementation in routine clinical practice. Three hundred and sixty-two isolates of bacteria and yeast, consisting of a variety of clinical isolates and American Type Culture Collection strains, were tested. Results were compared with reference identifications from the VITEK 2 system and with 16S rRNA sequence analysis. The VITEK MS provided an acceptable identification to species level for 283 (78 %) isolates. Considering organisms for which genus-level identification is acceptable for routine clinical care, 315 isolates (87 %) had an acceptable identification. Six isolates (2 %) were identified incorrectly, five of which were Shigella species. Finally, the time for reporting the identifications was decreased significantly after implementation of the VITEK MS for a total mean reduction in time of 10.52 h (P<0.0001). Overall, accuracy of the VITEK MS was comparable or superior to that from the VITEK 2. The findings were also comparable to other studies examining the accuracy of the VITEK MS, although differences exist, depending on the diversity of species represented as well as on the versions of the databases used. The VITEK MS can be incorporated effectively into routine use in a clinical microbiology laboratory and future expansion of the database should provide improved accuracy for the identification of micro-organisms.

  14. Current status of verification practices in clinical biochemistry in Spain.

    PubMed

    Gómez-Rioja, Rubén; Alvarez, Virtudes; Ventura, Montserrat; Alsina, M Jesús; Barba, Núria; Cortés, Mariano; Llopis, María Antonia; Martínez, Cecilia; Ibarz, Mercè

    2013-09-01

    Verification uses logical algorithms to detect potential errors before laboratory results are released to the clinician. Even though verification is one of the main processes in all laboratories, there is a lack of standardization mainly in the algorithms used and the criteria and verification limits applied. A survey in clinical laboratories in Spain was conducted in order to assess the verification process, particularly the use of autoverification. Questionnaires were sent to the laboratories involved in the External Quality Assurance Program organized by the Spanish Society of Clinical Biochemistry and Molecular Pathology. Seven common biochemical parameters were included (glucose, cholesterol, triglycerides, creatinine, potassium, calcium, and alanine aminotransferase). Completed questionnaires were received from 85 laboratories. Nearly all the laboratories reported using the following seven verification criteria: internal quality control, instrument warnings, sample deterioration, reference limits, clinical data, concordance between parameters, and verification of results. The use of all verification criteria varied according to the type of verification (automatic, technical, or medical). Verification limits for these parameters are similar to biological reference ranges. Delta Check was used in 24% of laboratories. Most laboratories (64%) reported using autoverification systems. Autoverification use was related to laboratory size, ownership, and type of laboratory information system, but amount of use (percentage of test autoverified) was not related to laboratory size. A total of 36% of Spanish laboratories do not use autoverification, despite the general implementation of laboratory information systems, most of them, with autoverification ability. Criteria and rules for seven routine biochemical tests were obtained.

  15. Performance analysis of automated evaluation of Crithidia luciliae-based indirect immunofluorescence tests in a routine setting - strengths and weaknesses.

    PubMed

    Hormann, Wymke; Hahn, Melanie; Gerlach, Stefan; Hochstrate, Nicola; Affeldt, Kai; Giesen, Joyce; Fechner, Kai; Damoiseaux, Jan G M C

    2017-11-27

    Antibodies directed against dsDNA are a highly specific diagnostic marker for the presence of systemic lupus erythematosus and of particular importance in its diagnosis. To assess anti-dsDNA antibodies, the Crithidia luciliae-based indirect immunofluorescence test (CLIFT) is one of the assays considered to be the best choice. To overcome the drawback of subjective result interpretation that inheres indirect immunofluorescence assays in general, automated systems have been introduced into the market during the last years. Among these systems is the EUROPattern Suite, an advanced automated fluorescence microscope equipped with different software packages, capable of automated pattern interpretation and result suggestion for ANA, ANCA and CLIFT analysis. We analyzed the performance of the EUROPattern Suite with its automated fluorescence interpretation for CLIFT in a routine setting, reflecting the everyday life of a diagnostic laboratory. Three hundred and twelve consecutive samples were collected, sent to the Central Diagnostic Laboratory of the Maastricht University Medical Centre with a request for anti-dsDNA analysis over a period of 7 months. Agreement between EUROPattern assay analysis and the visual read was 93.3%. Sensitivity and specificity were 94.1% and 93.2%, respectively. The EUROPattern Suite performed reliably and greatly supported result interpretation. Automated image acquisition is readily performed and automated image classification gives a reliable recommendation for assay evaluation to the operator. The EUROPattern Suite optimizes workflow and contributes to standardization between different operators or laboratories.

  16. Clinical Neuropathology practice news 1-2014: Pyrosequencing meets clinical and analytical performance criteria for routine testing of MGMT promoter methylation status in glioblastoma

    PubMed Central

    Preusser, Matthias; Berghoff, Anna S.; Manzl, Claudia; Filipits, Martin; Weinhäusel, Andreas; Pulverer, Walter; Dieckmann, Karin; Widhalm, Georg; Wöhrer, Adelheid; Knosp, Engelbert; Marosi, Christine; Hainfellner, Johannes A.

    2014-01-01

    Testing of the MGMT promoter methylation status in glioblastoma is relevant for clinical decision making and research applications. Two recent and independent phase III therapy trials confirmed a prognostic and predictive value of the MGMT promoter methylation status in elderly glioblastoma patients. Several methods for MGMT promoter methylation testing have been proposed, but seem to be of limited test reliability. Therefore, and also due to feasibility reasons, translation of MGMT methylation testing into routine use has been protracted so far. Pyrosequencing after prior DNA bisulfite modification has emerged as a reliable, accurate, fast and easy-to-use method for MGMT promoter methylation testing in tumor tissues (including formalin-fixed and paraffin-embedded samples). We performed an intra- and inter-laboratory ring trial which demonstrates a high analytical performance of this technique. Thus, pyrosequencing-based assessment of MGMT promoter methylation status in glioblastoma meets the criteria of high analytical test performance and can be recommended for clinical application, provided that strict quality control is performed. Our article summarizes clinical indications, practical instructions and open issues for MGMT promoter methylation testing in glioblastoma using pyrosequencing. PMID:24359605

  17. Circadian temperature rhythms of older people

    NASA Technical Reports Server (NTRS)

    Monk, T. H.; Buysse, D. J.; Reynolds, C. F. 3rd; Kupfer, D. J.; Houck, P. R.

    1995-01-01

    This collection of studies had the aim of exploring whether older (77+ years) men and women have circadian body temperature rhythms different from those of younger adults. A total of 20 older men and 28 older women were compared with either 22 young men or 14 middle-aged men in four protocols; all but the first protocol using a subset of the sample. The four protocols were: 1) 24 h, and 2) 72 h data collections on a normal laboratory routine (sleeping at night); 3) between 36 h and 153 h of field data collection at home; and 4) 36 h of a constant conditions routine (wakeful bedrest under temporal isolation) in the laboratory. There was some evidence for an age-related phase advance in temperature rhythm, especially for the older men on a normal routine, though this was not present in the constant conditions protocol, where 5 of the older subjects showed major delays in the timing of the body temperature trough (10:00 or later). There was no statistically significant evidence from any of the protocols that older subjects generally had lower temperature rhythm amplitudes than younger adults. Only when older men were compared with younger men in 24-h rhythm amplitude by simple t-test did any comparison involving amplitude achieve statistical significance (p < 0.05).

  18. Assessing the cost-effectiveness of a routine versus an extensive laboratory work-up in the diagnosis of anaemia in Dutch general practice.

    PubMed

    Kip, Michelle Ma; Schop, Annemarie; Stouten, Karlijn; Dekker, Soraya; Dinant, Geert-Jan; Koffijberg, Hendrik; Bindels, Patrick Je; IJzerman, Maarten J; Levin, Mark-David; Kusters, Ron

    2018-01-01

    Background Establishing the underlying cause of anaemia in general practice is a diagnostic challenge. Currently, general practitioners individually determine which laboratory tests to request (routine work-up) in order to diagnose the underlying cause. However, an extensive work-up (consisting of 14 tests) increases the proportion of patients correctly diagnosed. This study investigates the cost-effectiveness of this extensive work-up. Methods A decision-analytic model was developed, incorporating all societal costs from the moment a patient presents to a general practitioner with symptoms suggestive of anaemia (aged ≥ 50 years), until the patient was (correctly) diagnosed and treated in primary care, or referred to (and diagnosed in) secondary care. Model inputs were derived from an online survey among general practitioners, expert estimates and published data. The primary outcome measure was expressed as incremental cost per additional patient diagnosed with the correct underlying cause of anaemia in either work-up. Results The probability of general practitioners diagnosing the correct underlying cause increased from 49.6% (95% CI: 44.8% to 54.5%) in the routine work-up to 56.0% (95% CI: 51.2% to 60.8%) in the extensive work-up (i.e. +6.4% [95% CI: -0.6% to 13.1%]). Costs are expected to increase slightly from €842/patient (95% CI: €704 to €994) to €845/patient (95% CI: €711 to €994), i.e. +€3/patient (95% CI: €-35 to €40) in the extensive work-up, indicating incremental costs of €43 per additional patient correctly diagnosed. Conclusions The extensive laboratory work-up is more effective for diagnosing the underlying cause of anaemia by general practitioners, at a minimal increase in costs. As accompanying benefits in terms of quality of life and reduced productivity losses could not be captured in this analysis, the extensive work-up is likely cost-effective.

  19. Quality Assessment of Urinary Stone Analysis: Results of a Multicenter Study of Laboratories in Europe

    PubMed Central

    Siener, Roswitha; Buchholz, Noor; Daudon, Michel; Hess, Bernhard; Knoll, Thomas; Osther, Palle J.; Reis-Santos, José; Sarica, Kemal; Traxer, Olivier; Trinchieri, Alberto

    2016-01-01

    After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction and chemical analysis. The aim of the present study was to assess the quality of urinary stone analysis of laboratories in Europe. Nine laboratories from eight European countries participated in six quality control surveys for urinary calculi analyses of the Reference Institute for Bioanalytics, Bonn, Germany, between 2010 and 2014. Each participant received the same blinded test samples for stone analysis. A total of 24 samples, comprising pure substances and mixtures of two or three components, were analysed. The evaluation of the quality of the laboratory in the present study was based on the attainment of 75% of the maximum total points, i.e. 99 points. The methods of stone analysis used were infrared spectroscopy (n = 7), chemical analysis (n = 1) and X-ray diffraction (n = 1). In the present study only 56% of the laboratories, four using infrared spectroscopy and one using X-ray diffraction, fulfilled the quality requirements. According to the current standard, chemical analysis is considered to be insufficient for stone analysis, whereas infrared spectroscopy or X-ray diffraction is mandatory. However, the poor results of infrared spectroscopy highlight the importance of equipment, reference spectra and qualification of the staff for an accurate analysis of stone composition. Regular quality control is essential in carrying out routine stone analysis. PMID:27248840

  20. Quality Assessment of Urinary Stone Analysis: Results of a Multicenter Study of Laboratories in Europe.

    PubMed

    Siener, Roswitha; Buchholz, Noor; Daudon, Michel; Hess, Bernhard; Knoll, Thomas; Osther, Palle J; Reis-Santos, José; Sarica, Kemal; Traxer, Olivier; Trinchieri, Alberto

    2016-01-01

    After stone removal, accurate analysis of urinary stone composition is the most crucial laboratory diagnostic procedure for the treatment and recurrence prevention in the stone-forming patient. The most common techniques for routine analysis of stones are infrared spectroscopy, X-ray diffraction and chemical analysis. The aim of the present study was to assess the quality of urinary stone analysis of laboratories in Europe. Nine laboratories from eight European countries participated in six quality control surveys for urinary calculi analyses of the Reference Institute for Bioanalytics, Bonn, Germany, between 2010 and 2014. Each participant received the same blinded test samples for stone analysis. A total of 24 samples, comprising pure substances and mixtures of two or three components, were analysed. The evaluation of the quality of the laboratory in the present study was based on the attainment of 75% of the maximum total points, i.e. 99 points. The methods of stone analysis used were infrared spectroscopy (n = 7), chemical analysis (n = 1) and X-ray diffraction (n = 1). In the present study only 56% of the laboratories, four using infrared spectroscopy and one using X-ray diffraction, fulfilled the quality requirements. According to the current standard, chemical analysis is considered to be insufficient for stone analysis, whereas infrared spectroscopy or X-ray diffraction is mandatory. However, the poor results of infrared spectroscopy highlight the importance of equipment, reference spectra and qualification of the staff for an accurate analysis of stone composition. Regular quality control is essential in carrying out routine stone analysis.

  1. The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia.

    PubMed

    Rosenthal, Mark; Ugele, Bernhard; Lipowsky, Gerd; Küster, Helmut

    2006-02-01

    The aim of this prospective observational study was to compare a bedside test with the reference laboratory method in routine postnatal glucose monitoring. Term newborns with increased risk or clinical signs of hypoglycemia were screened with a bedside test. In case of a glucose value below 2.25 mmol/L, a second blood sample was taken and a duplicate glucose measurement done in the laboratory using a bedside test (Accutrend sensor) and the reference laboratory method (hexokinase method) at the same time and from the same sample. From 110 term newborns, 122 blood samples were obtained for duplicate measurements (median 1.69 mmol/L, SD 0.45 mmol/L). Of these 122, Accutrend correctly identified 97% as being <2.25 mmol/L by the laboratory method. A Bland-Altman plot revealed a mean underestimation of the Accutrend of only -0.09 mmol/L. However, due to high scattering, the maximal over- and underestimation was 0.89 and 1.39 mmol/L, respectively. Only 75% of the results from the Accutrend were within +/-20% of the result of the laboratory method. If the cut-off for low glucose concentrations was set 0.6 mmol/L higher for the bedside test as compared to the laboratory method, all patients except one would have been correctly identified as hypoglycemic. When using the Accutrend sensor, single infants with even marked hypoglycemia might be missed. Some delay in receiving accurate measurements might be more helpful for clinical decisions and long-term outcome than immediate but potentially misleading results.

  2. Physician Satisfaction With Clinical Laboratory Services: A College of American Pathologists Q-Probes Study of 81 Institutions.

    PubMed

    McCall, Shannon J; Souers, Rhona J; Blond, Barbara; Massie, Larry

    2016-10-01

    -Assessment of customer satisfaction is a vital component of the laboratory quality improvement program. -To survey the level of physician satisfaction with hospital clinical laboratory services. -Participating institutions provided demographic information and survey results of physician satisfaction, with specific features of clinical laboratory services individually rated on a scale of 5 (excellent) to 1 (poor). -Eighty-one institutions submitted 2425 surveys. The median overall satisfaction score was 4.2 (10th percentile, 3.6; 90th percentile, 4.6). Of the 16 surveyed areas receiving the highest percentage of excellent/good ratings (combined scores of 4 and 5), quality of results was highest along with test menu adequacy, staff courtesy, and overall satisfaction. Of the 4 categories receiving the lowest percentage values of excellent/good ratings, 3 were related to turnaround time for inpatient "STAT" (tests performed immediately), outpatient STAT, and esoteric tests. The fourth was a new category presented in this survey: ease of electronic order entry. Here, 11.4% (241 of 2121) of physicians assigned below-average (2) or poor (1) scores. The 5 categories deemed most important to physicians included quality of results, turnaround times for inpatient STAT, routine, and outpatient STAT tests, and clinical report format. Overall satisfaction as measured by physician willingness to recommend their laboratory to another physician remains high at 94.5% (2160 of 2286 respondents). -There is a continued trend of high physician satisfaction and loyalty with clinical laboratory services. Physician dissatisfaction with ease of electronic order entry represents a new challenge. Test turnaround times are persistent areas of dissatisfaction, representing areas for improvement.

  3. A survey of current practices for genomic sequencing test interpretation and reporting processes in US laboratories.

    PubMed

    O'Daniel, Julianne M; McLaughlin, Heather M; Amendola, Laura M; Bale, Sherri J; Berg, Jonathan S; Bick, David; Bowling, Kevin M; Chao, Elizabeth C; Chung, Wendy K; Conlin, Laura K; Cooper, Gregory M; Das, Soma; Deignan, Joshua L; Dorschner, Michael O; Evans, James P; Ghazani, Arezou A; Goddard, Katrina A; Gornick, Michele; Farwell Hagman, Kelly D; Hambuch, Tina; Hegde, Madhuri; Hindorff, Lucia A; Holm, Ingrid A; Jarvik, Gail P; Knight Johnson, Amy; Mighion, Lindsey; Morra, Massimo; Plon, Sharon E; Punj, Sumit; Richards, C Sue; Santani, Avni; Shirts, Brian H; Spinner, Nancy B; Tang, Sha; Weck, Karen E; Wolf, Susan M; Yang, Yaping; Rehm, Heidi L

    2017-05-01

    While the diagnostic success of genomic sequencing expands, the complexity of this testing should not be overlooked. Numerous laboratory processes are required to support the identification, interpretation, and reporting of clinically significant variants. This study aimed to examine the workflow and reporting procedures among US laboratories to highlight shared practices and identify areas in need of standardization. Surveys and follow-up interviews were conducted with laboratories offering exome and/or genome sequencing to support a research program or for routine clinical services. The 73-item survey elicited multiple choice and free-text responses that were later clarified with phone interviews. Twenty-one laboratories participated. Practices highly concordant across all groups included consent documentation, multiperson case review, and enabling patient opt-out of incidental or secondary findings analysis. Noted divergence included use of phenotypic data to inform case analysis and interpretation and reporting of case-specific quality metrics and methods. Few laboratory policies detailed procedures for data reanalysis, data sharing, or patient access to data. This study provides an overview of practices and policies of experienced exome and genome sequencing laboratories. The results enable broader consideration of which practices are becoming standard approaches, where divergence remains, and areas of development in best practice guidelines that may be helpful.Genet Med advance online publication 03 Novemeber 2016.

  4. [Thalassaemia diagnostics].

    PubMed

    Kusters, Elske; Kerkhoffs, Jean-Louis H; van Rossum, André P

    2014-01-01

    The thalassaemias are characterised by quantitative aberrations in the production of the globin chains that make up haemoglobin, and are a subgroup of the haemoglobinopathies. In this LabQuiz we show how thalassaemia carrier status can be indicated in the results of regular laboratory tests, and discuss the laboratory diagnostics that can confirm or rule out thalassaemia. In these two cases we will present a man of Moroccan descent, and two brothers of Filipino descent, all with anaemia and microcytosis. We show it is possible to differentiate between iron-deficiency anaemia and thalassaemia carrier status on the basis of a complete blood count and measurement of ferritin levels, and which laboratory diagnostics can be subsequently performed in order to confirm a suspicion of thalassaemia. The background section discusses the properties and pitfalls of routine laboratory diagnostics for the thalassaemias, and thalassaemia diagnostics in the Dutch newborn screening programme.

  5. Laboratory diagnosis of gestational diabetes: An in silico investigation into the effects of pre-analytical processing on the diagnostic sensitivity and specificity of the oral glucose tolerance test.

    PubMed

    Mansell, Erin; Lunt, Helen; Docherty, Paul

    2017-06-01

    Delayed separation of red cells from plasma causes pre analytical glucose loss, which in turn results in an under-diagnosis of GDM (gestational diabetes) based on the OGTT (oral glucose tolerance test). In silico investigations may help laboratory decision making, when exploring pragmatic improvements to sample processing. Late pregnancy 0, 1 and 2h 75g OGTT values were obtained from two distinct populations of pregnant women: 1. Values derived from the HAPO (Hyperglycemia and Adverse Pregnancy Outcome) Study and 2. New Zealand women identified as at higher risk of GDM by their caregivers, undergoing OGTT during routine antenatal care. In both populations studied, in silico modelling focussed on the effects of pre-analytical delays in plasma separation, when using fluoride collection tubes. Using a model that 'batched' samples from the three OGTT collection times, diagnostic sensitivity was estimated as follows: 66.1% for HAPO research population and 48.4% for the 1305 women receiving routine antenatal care. If samples were not batched, but processed shortly after each blood sample was collected, then sensitivity increased to 81%. Exploration of a range of clinical and laboratory scenarios using in silico modelling, showed that delaying the processing of pregnancy OGTT samples, using batched sample collection into fluoride tubes, causes unacceptable loss of GDM diagnostic sensitivity across two distinct population groups. This modelling approach will hopefully provide information that helps with final decision making around improved laboratory processing techniques. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Operational challenges in delivering CD4 diagnostics in sub-Saharan Africa.

    PubMed

    Thairu, L; Katzenstein, D; Israelski, D

    2011-07-01

    Access to reliable and low cost CD4 T-cell enumeration to stage illness and monitor anti-retroviral therapy remains elusive in resource-limited settings. We report challenges in delivering CD4 testing using the microcapillary Fluorescence-Activated Cell Sorter (FACS) methodology (Guava EasyCD4 instrument Guava Technologies, Hayward) in Burkina Faso and Zimbabwe. Resources, instruments, reagents, and training were provided to local laboratories within the existing infrastructure and data on CD4 were collected from routine laboratory testing. Challenges encountered included frequent instrument breakdown; poor manufacturer maintenance; difficulties in managing reagent stocks; high technician turnover; reliance on antiquated data management systems; redundant service provision; and lack of repeat testing in male HIV+ patients and in patients with higher CD4 counts after initial staging. While adopting newer, less expensive technologies such as fluorescent platforms and point of care tests can facilitate access to lower cost CD4 testing, our experience suggests that supply chain, corporate commitment to implementation, and community factors also require consideration.

  7. Biochemical phenotypes to discriminate microbial subpopulations and improve outbreak detection.

    PubMed

    Galar, Alicia; Kulldorff, Martin; Rudnick, Wallis; O'Brien, Thomas F; Stelling, John

    2013-01-01

    Clinical microbiology laboratories worldwide constitute an invaluable resource for monitoring emerging threats and the spread of antimicrobial resistance. We studied the growing number of biochemical tests routinely performed on clinical isolates to explore their value as epidemiological markers. Microbiology laboratory results from January 2009 through December 2011 from a 793-bed hospital stored in WHONET were examined. Variables included patient location, collection date, organism, and 47 biochemical and 17 antimicrobial susceptibility test results reported by Vitek 2. To identify biochemical tests that were particularly valuable (stable with repeat testing, but good variability across the species) or problematic (inconsistent results with repeat testing), three types of variance analyses were performed on isolates of K. pneumonia: descriptive analysis of discordant biochemical results in same-day isolates, an average within-patient variance index, and generalized linear mixed model variance component analysis. 4,200 isolates of K. pneumoniae were identified from 2,485 patients, 32% of whom had multiple isolates. The first two variance analyses highlighted SUCT, TyrA, GlyA, and GGT as "nuisance" biochemicals for which discordant within-patient test results impacted a high proportion of patient results, while dTAG had relatively good within-patient stability with good heterogeneity across the species. Variance component analyses confirmed the relative stability of dTAG, and identified additional biochemicals such as PHOS with a large between patient to within patient variance ratio. A reduced subset of biochemicals improved the robustness of strain definition for carbapenem-resistant K. pneumoniae. Surveillance analyses suggest that the reduced biochemical profile could improve the timeliness and specificity of outbreak detection algorithms. The statistical approaches explored can improve the robust recognition of microbial subpopulations with routinely available biochemical test results, of value in the timely detection of outbreak clones and evolutionarily important genetic events.

  8. [Development and equivalence evaluation of spondee lists of mandarin speech test materials].

    PubMed

    Zhang, Hua; Wang, Shuo; Wang, Liang; Chen, Jing; Chen, Ai-ting; Guo, Lian-sheng; Zhao, Xiao-yan; Ji, Chen

    2006-06-01

    To edit the spondee (disyllable) word lists as a part of mandarin speech test materials (MSTM). These will be basic speech materials for routine tests in clinics and laboratories. Two groups of professionals (audiologists, Chinese and Mandarin scientists, linguistician and statistician) were set up at first. The editing principles were established after 3 round table meetings. Ten spondee lists, each with 50 words, were edited and recorded into cassettes. All lists were phonemically balanced (3-dimensions: vowels, consonants and Chinese tones). Seventy-three normal hearing college students were tested. The speech was presented by earphone monaurally. Three statistic methods were used for equivalent analysis. Related analysis showed that all lists were much related, except List 5. Cluster analysis showed that all ten lists could be classified as two groups. But Kappa test showed that the lists' homogeneity were not well. Spondee lists are one of the most routine speech test materials. Their editing, recording and equivalent evaluation are affected by many factors. This also needs multi-discipline cooperation. All lists edited in present study need future modification in recording and testing in order to be used clinically and in research. The phonemic balance should be kept.

  9. Sun position calculator (SPC) for Landsat imagery with geodetic latitudes

    NASA Astrophysics Data System (ADS)

    Seong, Jeong C.

    2015-12-01

    Landsat imagery comes with sun position information such as azimuth and sun elevation, but they are available only at the center of a scene. To aid in the use of Landsat imagery for various solar radiation applications such as topographic correction, solar power, urban heat island, agriculture, climate and vegetation, it is necessary to calculate the sun position information at every pixel. This research developed a PC application that creates sun position data layers in ArcGIS at every pixel in a Landsat scene. The SPC program is composed of two major routines - converting universal transverse Mercator (UTM) projection coordinates to geographic longitudes and latitudes, and calculating sun position information based on the Meeus' routine. For the latter, an innovative method was also implemented to account for the Earth's flattening on an ellipsoid. The Meeus routine implemented in this research showed about 0.2‧ of mean absolute difference from the National Renewable Energy Laboratory (NREL) Solar Position Algorithm (SPA) routine when solar zenith and azimuth angles were tested with every 30 min data at four city locations (Fairbanks, Atlanta, Sydney and Rio Grande) on June 30, 2014. The Meeus routine was about ten times faster than the SPA routine. Professionals who need the Sun's position information for Landsat imagery will benefit from the SPC application.

  10. The potential of high resolution melting analysis (hrma) to streamline, facilitate and enrich routine diagnostics in medical microbiology.

    PubMed

    Ruskova, Lenka; Raclavsky, Vladislav

    2011-09-01

    Routine medical microbiology diagnostics relies on conventional cultivation followed by phenotypic techniques for identification of pathogenic bacteria and fungi. This is not only due to tradition and economy but also because it provides pure culture needed for antibiotic susceptibility testing. This review focuses on the potential of High Resolution Melting Analysis (HRMA) of double-stranded DNA for future routine medical microbiology. Search of MEDLINE database for publications showing the advantages of HRMA in routine medical microbiology for identification, strain typing and further characterization of pathogenic bacteria and fungi in particular. The results show increasing numbers of newly-developed and more tailor-made assays in this field. For microbiologists unfamiliar with technical aspects of HRMA, we also provide insight into the technique from the perspective of microbial characterization. We can anticipate that the routine availability of HRMA in medical microbiology laboratories will provide a strong stimulus to this field. This is already envisioned by the growing number of medical microbiology applications published recently. The speed, power, convenience and cost effectiveness of this technology virtually predestine that it will advance genetic characterization of microbes and streamline, facilitate and enrich diagnostics in routine medical microbiology without interfering with the proven advantages of conventional cultivation.

  11. Three Rounds of External Quality Assessment in France to Evaluate the Performance of 28 Platforms for Multiparametric Molecular Testing in Metastatic Colorectal and Non-Small Cell Lung Cancer.

    PubMed

    Dequeker, Elisabeth M C; Keppens, Cleo; Egele, Caroline; Delen, Sofie; Lamy, Aude; Lemoine, Antoinette; Sabourin, Jean-Christophe; Andrieu, Catherine; Ligtenberg, Marjolijn; Fetique, Dominique; Tops, Bastiaan; Descarpentries, Clotilde; Blons, Hélène; Denoux, Yves; Aube, Cécile; Penault-Llorca, Frederique; Hofman, Paul; Leroy, Karen; Le Marechal, Cédric; Doucet, Laurent; Duranton-Tanneur, Valérie; Pedeutour, Florence; Soubeyran, Isabelle; Côté, Jean-François; Emile, Jean-François; Vignaud, Jean-Michel; Monhoven, Nathalie; Haddad, Véronique; Laurent-Puig, Pierre; van Krieken, Han; Nowak, Frederique; Lonchamp, Etienne; Bellocq, Jean-Pierre; Rouleau, Etienne

    2016-03-01

    Personalized medicine has gained increasing importance in clinical oncology, and several clinically important biomarkers are implemented in routine practice. In an effort to guarantee high quality of molecular testing in France, three subsequent external quality assessment rounds were organized at the initiative of the National Cancer Institute between 2012 and 2014. The schemes included clinically relevant biomarkers for metastatic colorectal (KRAS, NRAS, BRAF, PIK3CA, microsatellite instability) and non-small cell lung cancer (EGFR, KRAS, BRAF, PIK3CA, ERBB2), and they represent the first multigene/multicancer studies throughout Europe. In total, 56 laboratories coordinated by 28 regional molecular centers participated in the schemes. Laboratories received formalin-fixed, paraffin-embedded samples and were asked to use routine methods for molecular testing to predict patient response to targeted therapies. They were encouraged to return results within 14 calendar days after sample receipt. Both genotyping and reporting were evaluated separately. During the three external quality assessment rounds, mean genotype scores were all above the preset standard of 90% for all biomarkers. Participants were mainly challenged in case of rare insertions or deletions. Assessment of the written reports showed substantial progress between the external quality assessment schemes on multiple criteria. Several essential elements such as the clinical interpretation of test results and the reason for testing still require improvement by continued external quality assessment education. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  12. A Real-World Setting Study: Which Glucose Meter Could Be the Best for POCT Use? An Easy and Applicable Protocol During the Hospital Routine.

    PubMed

    Mancini, Alessio; Esposto, Giampaolo; Manfrini, Silvana; Rilli, Silvia; Tinti, Gessica; Carta, Giuseppe; Petrolati, Laura; Vidali, Matteo; Barocci, Simone

    2018-05-01

    The aim of this retrospective study is to evaluate the reliability and robustness of six glucose meters for point-of-care testing in our wards using a brand-new protocol. During a 30-days study period a total of 50 diabetes patients were subjected to venous blood sampling and glucose meter blood analysis. The results of six glucose meters were compared with our laboratory reference assay. GlucoMen Plus (Menarini) with the 82% of acceptable results was the most robust glucose meter. Even if the Passing-Bablok analysis demonstrates the presence of constant systematic errors and the Bland-Altman test highlighted a possible overestimation, the surveillance error grid analysis showed that this glucose meter can be used safely. We proved that portable glucose meters are not always reliable in routinely clinical settings.

  13. Varied presentations of early congenital syphilis.

    PubMed

    Basu, Sriparna; Kumar, Ashok

    2013-06-01

    In spite of availability of cost-effective preventive measures and treatment, a resurgence of congenital syphilis has currently been noted. During the past 4 years, we came across five low birth weight neonates with unusual symptoms, which subsequently proved to be manifestations of early congenital syphilis. All the mothers had apparently uneventful antenatal period. No investigation was done during pregnancy. They were unaware about their disease and were found to be positive for syphilis by Venereal Disease Research Laboratory Test and fluorescent treponemal antibody (absorbed) IgM test only after childbirth. Screening for other congenital infections was negative. All the neonates were positive for Venereal Disease Research Laboratory Test. They were treated with intravenous crystalline penicillin G for 10 days. Recovery was uneventful. We reemphasize the importance of raising public awareness, routine antenatal screening and treatment for all pregnant mothers to avoid such a potentially treatable condition.

  14. Correlation between microdilution, Etest, and disk diffusion methods for antifungal susceptibility testing of fluconazole against Candida sp. blood isolates.

    PubMed

    Menezes, Everardo Albuquerque; Vasconcelos Júnior, Antônio Alexandre de; Ângelo, Maria Rozzelê Ferreira; Cunha, Maria da Conceição dos Santos Oliveira; Cunha, Francisco Afrânio

    2013-01-01

    Antifungal susceptibility testing assists in finding the appropriate treatment for fungal infections, which are increasingly common. However, such testing is not very widespread. There are several existing methods, and the correlation between such methods was evaluated in this study. The susceptibility to fluconazole of 35 strains of Candida sp. isolated from blood cultures was evaluated by the following methods: microdilution, Etest, and disk diffusion. The correlation between the methods was around 90%. The disk diffusion test exhibited a good correlation and can be used in laboratory routines to detect strains of Candida sp. that are resistant to fluconazole.

  15. Going beyond audit and feedback: towards behaviour-based interventions to change physician laboratory test ordering behaviour.

    PubMed

    Meidani, Z; Mousavi, G A; Kheirkhah, D; Benar, N; Maleki, M R; Sharifi, M; Farrokhian, A

    2017-12-01

    Studies indicate there are a variety of contributing factors affecting physician test ordering behaviour. Identifying these behaviours allows development of behaviour-based interventions. Methods Through a pilot study, the list of contributing factors in laboratory tests ordering, and the most ordered tests, were identified, and given to 50 medical students, interns, residents and paediatricians in questionnaire form. The results showed routine tests and peer or supervisor pressure as the most influential factors affecting physician ordering behaviour. An audit and feedback mechanism was selected as an appropriate intervention to improve physician ordering behaviour. The intervention was carried out at two intervals over a three-month period. Findings There was a large reduction in the number of laboratory tests ordered; from 908 before intervention to 389 and 361 after first and second intervention, respectively. There was a significant relationship between audit and feedback and the meaningful reduction of 7 out of 15 laboratory tests including complete blood count (p = 0.002), erythrocyte sedimentation rate (p = 0.01), C-reactive protein (p = 0.01), venous blood gas (p = 0.016), urine analysis (p = 0.005), blood culture (p = 0.045) and stool examination (p = 0.001). Conclusion The audit and feedback intervention, even in short duration, affects physician ordering behaviour. It should be designed in terms of behaviour-based intervention and diagnosis of the contributing factors in physicians' behaviour. Further studies are required to substantiate the effectiveness of such behaviour-based intervention strategies in changing physician behaviour.

  16. Procedures For Microbial-Ecology Laboratory

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1993-01-01

    Microbial Ecology Laboratory Procedures Manual provides concise and well-defined instructions on routine technical procedures to be followed in microbiological laboratory to ensure safety, analytical control, and validity of results.

  17. [Urinalysis in Italy in 2006].

    PubMed

    Gai, M; Lanfranco, G

    2007-01-01

    Urinalysis and proteinuria testing represent fundamental tests for the clinician, even though they too often lack standardization. Through the Italian Society of Nephrology Mailing List we sent a questionnaire to 282 centers, in order to assess the state of the art in Italy in the year 2006. 82% of the questionnaires were completed (nephrology laboratories: 64%, general laboratories: 36%). The questionnaire dealt with the main steps of preparation, analysis and report of urinalysis, and proteinuria / microalbuminuria measurement. 85% of the centers use first morning urine, and 7% second morning urine; only 57% of the centers supply with written instructions, 189 laboratories (82%) have only one bright field microscope, rate and time of centrifugation are very varied among centers, different units of measurement are used in reports. Few laboratories measure routinely the proteinuria / creatininuria ratio, there is no agreement on the urine sample type for microalbuminuria assay, total urinary proteins are measured through different methods. 92% of the centers is endowed with an internal quality control system, but only 47% participate in an external quality control program. These data confirm the lack of standardization for urine analysis methods and procedures.

  18. CHROMagar Orientation Medium Reduces Urine Culture Workload

    PubMed Central

    Manickam, Kanchana; Karlowsky, James A.; Adam, Heather; Lagacé-Wiens, Philippe R. S.; Rendina, Assunta; Pang, Paulette; Murray, Brenda-Lee

    2013-01-01

    Microbiology laboratories continually strive to streamline and improve their urine culture algorithms because of the high volumes of urine specimens they receive and the modest numbers of those specimens that are ultimately considered clinically significant. In the current study, we quantitatively measured the impact of the introduction of CHROMagar Orientation (CO) medium into routine use in two hospital laboratories and compared it to conventional culture on blood and MacConkey agars. Based on data extracted from our Laboratory Information System from 2006 to 2011, the use of CO medium resulted in a 28% reduction in workload for additional procedures such as Gram stains, subcultures, identification panels, agglutination tests, and biochemical tests. The average number of workload units (one workload unit equals 1 min of hands-on labor) per urine specimen was significantly reduced (P < 0.0001; 95% confidence interval [CI], 0.5326 to 1.047) from 2.67 in 2006 (preimplementation of CO medium) to 1.88 in 2011 (postimplementation of CO medium). We conclude that the use of CO medium streamlined the urine culture process and increased bench throughput by reducing both workload and turnaround time in our laboratories. PMID:23363839

  19. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    PubMed

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  20. Identification of genus Acinetobacter: Standardization of in-house PCR and its comparison with conventional phenotypic methods.

    PubMed

    Kulkarni, Sughosh S; Madalgi, Radhika; Ajantha, Ganavalli S; Kulkarni, Raghavendra D

    2017-01-01

    Acinetobacter is grouped under nonfermenting Gram-negative bacilli. It is increasingly isolated from pathological samples. The ability of this genus to acquire drug resistance and spread in the hospital settings is posing a grave problem in healthcare. Specific treatment protocols are advocated for Acinetobacter infections. Hence, rapid identification and drug susceptibility profiling are critical in the management of these infections. To standardize an in-house polymerase chain reaction (PCR) for identification of genus Acinetobacter and to compare PCR with two protocols for its phenotypic identification. A total of 96 clinical isolates of Acinetobacter were included in the study. An in-house PCR for genus level identification of Acinetobacter was standardized. All the isolates were phenotypically identified by two protocols. The results of PCR and phenotypic identification protocols were compared. The in-house PCR standardized was highly sensitive and specific for the genus Acinetobacter . There was 100% agreement between the phenotypic and molecular identification of the genus. The preliminary identification tests routinely used in clinical laboratories were also in complete agreement with phenotypic and molecular identification. The in-house PCR for genus level identification is specific and sensitive. However, it may not be essential for routine identification as the preliminary phenotypic identification tests used in the clinical laboratory reliably identify the genus Acinetobacter .

  1. Ground-Based Aerosol Measurements | Science Inventory ...

    EPA Pesticide Factsheets

    Atmospheric particulate matter (PM) is a complex chemical mixture of liquid and solid particles suspended in air (Seinfeld and Pandis 2016). Measurements of this complex mixture form the basis of our knowledge regarding particle formation, source-receptor relationships, data to test and verify complex air quality models, and how PM impacts human health, visibility, global warming, and ecological systems (EPA 2009). Historically, PM samples have been collected on filters or other substrates with subsequent chemical analysis in the laboratory and this is still the major approach for routine networks (Chow 2005; Solomon et al. 2014) as well as in research studies. In this approach, air, at a specified flow rate and time period, is typically drawn through an inlet, usually a size selective inlet, and then drawn through filters, 1 INTRODUCTION Atmospheric particulate matter (PM) is a complex chemical mixture of liquid and solid particles suspended in air (Seinfeld and Pandis 2016). Measurements of this complex mixture form the basis of our knowledge regarding particle formation, source-receptor relationships, data to test and verify complex air quality models, and how PM impacts human health, visibility, global warming, and ecological systems (EPA 2009). Historically, PM samples have been collected on filters or other substrates with subsequent chemical analysis in the laboratory and this is still the major approach for routine networks (Chow 2005; Solomo

  2. Field Evaluation of Dried Blood Spots for Routine HIV-1 Viral Load and Drug Resistance Monitoring in Patients Receiving Antiretroviral Therapy in Africa and Asia

    PubMed Central

    Monleau, Marjorie; Eymard-Duvernay, Sabrina; Dagnra, Anoumou; Kania, Dramane; Ngo-Giang-Huong, Nicole; Touré-Kane, Coumba; Truong, Lien X. T.; Chaix, Marie-Laure; Delaporte, Eric; Ayouba, Ahidjo; Peeters, Martine

    2014-01-01

    Dried blood spots (DBS) can be used in developing countries to alleviate the logistic constraints of using blood plasma specimens for viral load (VL) and HIV drug resistance (HIVDR) testing, but they should be assessed under field conditions. Between 2009 and 2011, we collected paired plasma-DBS samples from treatment-experienced HIV-1-infected adults in Burkina Faso, Cameroon, Senegal, Togo, Thailand, and Vietnam. The DBS were stored at an ambient temperature for 2 to 4 weeks and subsequently at −20°C before testing. VL testing was performed on the plasma samples and DBS using locally available methods: the Abbott m2000rt HIV-1 test, generic G2 real-time PCR, or the NucliSENS EasyQ version 1.2 test. In the case of virological failure (VF), i.e., a plasma VL of ≥1,000 copies/ml, HIVDR genotyping was performed on paired plasma-DBS samples. Overall, we compared 382 plasma-DBS sample pairs for DBS VL testing accuracy. The sensitivities of the different assays in different laboratories for detecting VF using DBS varied from 75% to 100% for the m2000rt test in labs B, C, and D, 91% to 93% for generic G2 real-time PCR in labs A and F, and 85% for the NucliSENS test in lab E. The specificities varied from 82% to 97% for the m2000rt and NucliSENS tests and reached only 60% for the generic G2 test. The NucliSENS test showed good agreement between plasma and DBS VL but underestimated the DBS VL. The lowest agreement was observed for the generic G2 test. Genotyping was successful for 96/124 (77%) DBS tested, and 75/96 (78%) plasma-DBS pairs had identical HIVDR mutations. Significant discrepancies in resistance interpretations were observed in 9 cases, 6 of which were from the same laboratory. DBS can be successfully used as an alternative to blood plasma samples for routine VL and HIVDR monitoring in African and Asian settings. However, the selection of an adequate VL measurement method and the definition of the VF threshold should be considered, and laboratory performance should be monitored. PMID:24478491

  3. Successful use of plasma exchange for profound hemolysis in a child with loxoscelism.

    PubMed

    Said, Ahmed; Hmiel, Paul; Goldsmith, Matthew; Dietzen, Dennis; Hartman, Mary E

    2014-11-01

    We describe a 6-year-old boy who presented with massive hemolysis, shock, disseminated intravascular coagulopathy, and acute renal failure after loxosceles envenomation. In this patient, plasma exchange therapy (PEX) successfully cleared the plasma from an initial hemolytic index of 2000 (equivalent to 2 g/dL hemoglobin, where optimetric laboratory evaluation is impossible) to an index of <50 (no detectable hemolysis). This allowed the PICU team to correct his coagulopathy, assess his degree of organ dysfunction, and provide routine laboratory assessments during continuous venovenous hemodiafiltration. After 9 single volume PEX sessions, his hemolysis and coagulopathy had resolved and his plasma had cleared sufficiently to permit routine laboratory assessments without difficulty. Multiorgan system support with an aggressive transfusion strategy, mechanical ventilation, inotropes, and continuous venovenous hemodiafiltration resulted in complete recovery. We conclude that in the presence of overwhelming hemolysis, plasma can become so icteric that optimetric laboratory evaluation is impossible. In this setting, PEX can be used to clear the plasma, restoring the ability to perform routine laboratory assessments. Copyright © 2014 by the American Academy of Pediatrics.

  4. A new laboratory-based surveillance system (Respiratory DataMart System) for influenza and other respiratory viruses in England: results and experience from 2009 to 2012.

    PubMed

    Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R

    2014-01-23

    During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.

  5. Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

    PubMed

    Helin, Tuukka A; Pakkanen, Anja; Lassila, Riitta; Joutsi-Korhonen, Lotta

    2013-05-01

    Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples. Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P < 0.005), with less prolongation in patient samples. TT results (Dabi) and calibrated anti-Xa results (Riva) were reported by only 11 and 8 laboratories, respectively. The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them. © 2013 American Association for Clinical Chemistry.

  6. 21 CFR 58.49 - Laboratory operation areas.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Laboratory operation areas. 58.49 Section 58.49... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Facilities § 58.49 Laboratory operation areas. Separate laboratory space shall be provided, as needed, for the performance of the routine and specialized...

  7. High-Temperature Modal Survey of a Hot-Structure Control Surface

    NASA Technical Reports Server (NTRS)

    Spivey, Natalie D.

    2011-01-01

    Ground vibration tests are routinely conducted for supporting flutter analysis for subsonic and supersonic vehicles; however, for hypersonic vehicles, thermoelastic vibration testing techniques are neither well established nor routinely performed. New high-temperature material systems, fabrication technologies and high-temperature sensors expand the opportunities to develop advanced techniques for performing ground vibration tests at elevated temperatures. When high-temperature materials, which increase in stiffness when heated, are incorporated into a hot-structure that contains metallic components that decrease in stiffness when heated, the interaction between those materials can affect the hypersonic flutter analysis. A high-temperature modal survey will expand the research database for hypersonics and improve the understanding of this dual-material interaction. This report discusses the vibration testing of the carbon-silicon carbide Ruddervator Subcomponent Test Article, which is a truncated version of a full-scale hot-structure control surface. Two series of room-temperature modal test configurations were performed in order to define the modal characteristics of the test article during the elevated-temperature modal survey: one with the test article suspended from a bungee cord (free-free) and the second with it mounted on the strongback (fixed boundary). Testing was performed in the NASA Dryden Flight Research Center Flight Loads Laboratory Large Nitrogen Test Chamber.

  8. [Point-of-care-testing--the intensive care laboratory].

    PubMed

    Müller, M M; Hackl, W; Griesmacher, A

    1999-01-01

    After successful centralization of laboratory analyses since more than 30 years, advances in biosensors, microprocessors, measurement of undiluted whole blood and miniaturization of laboratory analyzers are leading nowadays more and more to a re-decentralization in the laboratory medicine. Point-of-care-testing (POCT), which is defined as any laboratory test performed outside central or decentralized laboratories, is becoming more and more popular. The theoretical advantages of POCT are faster turn-around-times (TAT), more rapid medical decisions, avoidance of sample identification and sample transport problems and the need of only small specimen volumes. These advantages are frequently mentioned, but are not associated with a clear clinical benefit. The disadvantages of POCT such as incorrect handling and/or maintenance of the analyzers by nontrained clinical staff, inadequate or even absent calibrations and/or quality controls, lack of cost-effectiveness because of an increased number of analyzers and more expensive reagents, insufficient documentation and difficult comparability of the obtained POCT-results with routine laboratory results, are strongly evident. According to the authors' opinion the decision for the establishing of POCT has only to be made in a close co-operation between physicians and laboratorians in order to vouch for necessity and high quality of the analyses. Taking the local situation into consideration (24-h-central laboratory, etc.) the spectrum of parameters measured by means of POCT should be rigorously restricted to the vital functions. Such analytes should be: hemoglobin or hematocrit, activated whole blood clotting time, blood gases, sodium, potassium, ionized calcium, glucose, creatinine, ammonia and lactate.

  9. Evaluation of a PfHRP2 and a pLDH-based Rapid Diagnostic Test for the Diagnosis of Severe Malaria in 2 Populations of African Children

    PubMed Central

    Hendriksen, Ilse C. E.; Mtove, George; Pedro, Alínia José; Gomes, Ermelinda; Silamut, Kamolrat; Lee, Sue J.; Mwambuli, Abraham; Gesase, Samwel; Reyburn, Hugh; Day, Nicholas P. J.; White, Nicholas J.; von Seidlein, Lorenz

    2011-01-01

    Background. Rapid diagnostic tests (RDTs) now play an important role in the diagnosis of falciparum malaria in many countries where the disease is endemic. Although these tests have been extensively evaluated in uncomplicated falciparum malaria, reliable data on their performance for diagnosing potentially lethal severe malaria is lacking. Methods. We compared a Plasmodium falciparum histidine-rich-protein2 (PfHRP2)–based RDT and a Plasmodium lactate dehydrogenase (pLDH)–based RDT with routine microscopy of a peripheral blood slide and expert microscopy as a reference standard for the diagnosis of severe malaria in 1898 children who presented with severe febrile illness at 2 centers in Mozambique and Tanzania. Results. The overall sensitivity, specificity, positive predictive value, and negative predictive values of the PfHRP2-based test were 94.0%, 70.9%, 85.4%, and 86.8%, respectively, and for the pLDH-based test, the values were 88.0%, 88.3%, 93.2%, and 80.3%, respectively. At parasite counts <1000 parasites/μL (n = 173), sensitivity of the pLDH-based test was low (45.7%), compared with that of the PfHRP2-based test (69.9%). Both RDTs performed better than did the routine slide reading in a clinical laboratory as assessed in 1 of the centers. Conclusion. The evaluated PfHRP2-based RDT is an acceptable alternative to routine microscopy for diagnosing severe malaria in African children and performed better than did the evaluated pLDH-based RDT. PMID:21467015

  10. Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.

    PubMed

    Sommer, Jurg M; Buyue, Yang; Bardan, Sara; Peters, Robert T; Jiang, Haiyan; Kamphaus, George D; Gray, Elaine; Pierce, Glenn F

    2014-11-01

    Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneFIX® at 0.80, 0.20, or 0.05 IU/ml based on label potency. Laboratories tested blinded samples using their routine one-stage assay and in-house FIX plasma standard. The mean spike recoveries for BeneFIX (n=30 laboratories) were 121 %, 144 %, and 168 % of expected at nominal 0.80, 0.20, and 0.05 IU/ml concentrations, respectively. Corresponding rFIXFc spike recoveries were 88 %, 107 %, and 132 % of expected, respectively. All BeneFIX concentrations were consistently overestimated by most laboratories. rFIXFc activity was reagent-dependent; ellagic acid and silica gave higher values than kaolin, which underestimated rFIXFc. BeneFIX demonstrated significantly reduced chromogenic assay activity relative to one-stage assay results and nominal activity, while rFIXFc activity was close to nominal activity at three concentrations with better dilution linearity than the typical one-stage assay. In conclusion, laboratory- and reagent-specific assay variabilities were revealed, with progressively higher variability at lower FIX concentrations. Non-parallelism against the FIX plasma standard was observed in all one-stage assays with rFIXFc and BeneFIX, leading to significant overestimation of FIX activity at lower levels and generally high inter-laboratory variability. Compared to the accuracy currently achieved in clinical laboratories when measuring other rFIX products, most laboratories measured rFIXFc activity with acceptable accuracy and reliability using routine one-stage assay methods and commercially available plasma standards.

  11. Potential Impact of Rapid Blood Culture Testing for Gram-Positive Bacteremia in Japan with the Verigene Gram-Positive Blood Culture Test

    PubMed Central

    Matsuda, Mari; Iguchi, Shigekazu; Mizutani, Tomonori; Hiramatsu, Keiichi; Tega-Ishii, Michiru; Sansaka, Kaori; Negishi, Kenta; Shimada, Kimie; Umemura, Jun; Notake, Shigeyuki; Yanagisawa, Hideji; Yabusaki, Reiko; Araoka, Hideki; Yoneyama, Akiko

    2017-01-01

    Background. Early detection of Gram-positive bacteremia and timely appropriate antimicrobial therapy are required for decreasing patient mortality. The purpose of our study was to evaluate the performance of the Verigene Gram-positive blood culture assay (BC-GP) in two special healthcare settings and determine the potential impact of rapid blood culture testing for Gram-positive bacteremia within the Japanese healthcare delivery system. Furthermore, the study included simulated blood cultures, which included a library of well-characterized methicillin-resistant Staphylococcus aureus (MRSA) and vancomycin-resistant enterococci (VRE) isolates reflecting different geographical regions in Japan. Methods. A total 347 BC-GP assays were performed on clinical and simulated blood cultures. BC-GP results were compared to results obtained by reference methods for genus/species identification and detection of resistance genes using molecular and MALDI-TOF MS methodologies. Results. For identification and detection of resistance genes at two clinical sites and simulated blood cultures, overall concordance of BC-GP with reference methods was 327/347 (94%). The time for identification and antimicrobial resistance detection by BC-GP was significantly shorter compared to routine testing especially at the cardiology hospital, which does not offer clinical microbiology services on weekends and holidays. Conclusion. BC-GP generated accurate identification and detection of resistance markers compared with routine laboratory methods for Gram-positive organisms in specialized clinical settings providing more rapid results than current routine testing. PMID:28316631

  12. 75 FR 48698 - Medicare, Medicaid and CLIA Programs; COLA (Formerly the Commission on Office Laboratory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-11

    ..., including Syphilis Serology, General Immunology. Chemistry, including Routine Chemistry, Urinalysis.... Chemistry, including Routine Chemistry, Urinalysis, Endocrinology, Toxicology. Hematology. Immunohematology...

  13. 42 CFR 493.1267 - Standard: Routine chemistry.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Routine chemistry. 493.1267 Section 493.1267 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1267 Standard: Routine chemistry. For blood gas analyses, the laboratory must perform the...

  14. 42 CFR 493.1267 - Standard: Routine chemistry.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Standard: Routine chemistry. 493.1267 Section 493.1267 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1267 Standard: Routine chemistry. For blood gas analyses, the laboratory must perform the...

  15. 42 CFR 493.1267 - Standard: Routine chemistry.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Standard: Routine chemistry. 493.1267 Section 493.1267 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1267 Standard: Routine chemistry. For blood gas analyses, the laboratory must perform the...

  16. 42 CFR 493.1267 - Standard: Routine chemistry.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Standard: Routine chemistry. 493.1267 Section 493.1267 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1267 Standard: Routine chemistry. For blood gas analyses, the laboratory must perform the...

  17. 42 CFR 493.1267 - Standard: Routine chemistry.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Standard: Routine chemistry. 493.1267 Section 493.1267 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Systems § 493.1267 Standard: Routine chemistry. For blood gas analyses, the laboratory must perform the...

  18. Human Papillomavirus (HPV) Genotyping: Automation and Application in Routine Laboratory Testing

    PubMed Central

    Torres, M; Fraile, L; Echevarria, JM; Hernandez Novoa, B; Ortiz, M

    2012-01-01

    A large number of assays designed for genotyping human papillomaviruses (HPV) have been developed in the last years. They perform within a wide range of analytical sensitivity and specificity values for the different viral types, and are used either for diagnosis, epidemiological studies, evaluation of vaccines and implementing and monitoring of vaccination programs. Methods for specific genotyping of HPV-16 and HPV-18 are also useful for the prevention of cervical cancer in screening programs. Some commercial tests are, in addition, fully or partially automated. Automation of HPV genotyping presents advantages such as the simplicity of the testing procedure for the operator, the ability to process a large number of samples in a short time, and the reduction of human errors from manual operations, allowing a better quality assurance and a reduction of cost. The present review collects information about the current HPV genotyping tests, with special attention to practical aspects influencing their use in clinical laboratories. PMID:23248734

  19. MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory.

    PubMed

    Horowitz, Gary L; Zaman, Zahur; Blanckaert, Norbert J C; Chan, Daniel W; Dubois, Jeffrey A; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W; Nilsen, Olaug L; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang

    2005-01-01

    MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality.

  20. MODULAR ANALYTICS: A New Approach to Automation in the Clinical Laboratory

    PubMed Central

    Zaman, Zahur; Blanckaert, Norbert J. C.; Chan, Daniel W.; Dubois, Jeffrey A.; Golaz, Olivier; Mensi, Noury; Keller, Franz; Stolz, Herbert; Klingler, Karl; Marocchi, Alessandro; Prencipe, Lorenzo; McLawhon, Ronald W.; Nilsen, Olaug L.; Oellerich, Michael; Luthe, Hilmar; Orsonneau, Jean-Luc; Richeux, Gérard; Recio, Fernando; Roldan, Esther; Rymo, Lars; Wicktorsson, Anne-Charlotte; Welch, Shirley L.; Wieland, Heinrich; Grawitz, Andrea Busse; Mitsumaki, Hiroshi; McGovern, Margaret; Ng, Katherine; Stockmann, Wolfgang

    2005-01-01

    MODULAR ANALYTICS (Roche Diagnostics) (MODULAR ANALYTICS, Elecsys and Cobas Integra are trademarks of a member of the Roche Group) represents a new approach to automation for the clinical chemistry laboratory. It consists of a control unit, a core unit with a bidirectional multitrack rack transportation system, and three distinct kinds of analytical modules: an ISE module, a P800 module (44 photometric tests, throughput of up to 800 tests/h), and a D2400 module (16 photometric tests, throughput up to 2400 tests/h). MODULAR ANALYTICS allows customised configurations for various laboratory workloads. The performance and practicability of MODULAR ANALYTICS were evaluated in an international multicentre study at 16 sites. Studies included precision, accuracy, analytical range, carry-over, and workflow assessment. More than 700 000 results were obtained during the course of the study. Median between-day CVs were typically less than 3% for clinical chemistries and less than 6% for homogeneous immunoassays. Median recoveries for nearly all standardised reference materials were within 5% of assigned values. Method comparisons versus current existing routine instrumentation were clinically acceptable in all cases. During the workflow studies, the work from three to four single workstations was transferred to MODULAR ANALYTICS, which offered over 100 possible methods, with reduction in sample splitting, handling errors, and turnaround time. Typical sample processing time on MODULAR ANALYTICS was less than 30 minutes, an improvement from the current laboratory systems. By combining multiple analytic units in flexible ways, MODULAR ANALYTICS met diverse laboratory needs and offered improvement in workflow over current laboratory situations. It increased overall efficiency while maintaining (or improving) quality. PMID:18924721

  1. Acute Toxoplasma gondii infection in children with reactive hyperplasia of the cervical lymph nodes.

    PubMed

    Bilal, Jalal A; Alsammani, Mohamed A; Ahmed, Mohamed I

    2014-07-01

    To determine the seroprevalence of Toxoplasma gondii (T. gondii) in children with reactive hyperplasia of the cervical lymph nodes. This cross-sectional prospective study was conducted in Khartoum Children Emergency Hospital, Khartoum, Sudan between January 2010 and April 2011. Eighty children with cervical lymphadenopathy were selected using random sampling. Their lymph nodes were aspirated for cytology, and a blood sample was collected from all patients for routine laboratory analysis and T. gondii IgG and IgM antibodies. Among 80 children with cervical lymphadenopathy, 60 (75%) had non-specific reactive hyperplasia. The seroprevalence of T. gondii among children with cervical lymphadenopathy was 27.5% (n=22), and the seropositivity of acute T. gondii among those with reactive hyperplasia was 36.7% (n=22/60). Lymph nodes in the T. gondii positive group were mobile and warm (p<0.05). The clinical features and laboratory tests were insignificant predictors of acute T. gondii infection with reactive hyperplasia of the cervical lymph nodes. The prevalence of acute T. gondii infection is high among children with non-specific reactive hyperplasia of the cervical lymph nodes. Routine laboratory studies are not helpful in the diagnosis of T. gondii infection with reactive hyperplasia of the lymph nodes however, serological studies may be requested prior to invasive procedures.

  2. Quality Assurance of Rapid Diagnostic Tests for Malaria in Routine Patient Care in Rural Tanzania

    PubMed Central

    McMorrow, Meredith L.; Masanja, M. Irene; Kahigwa, Elizeus; Abdulla, Salim M. K.; Kachur, S. Patrick

    2010-01-01

    Histidine-rich protein II (HRP2)-based malaria rapid diagnostic tests (RDTs) have shown high sensitivity and specificity for detecting Plasmodium falciparum malaria in a variety of study settings. However, RDTs are susceptible to heat and humidity and variation in individual performance, which may affect their use in field settings. We evaluated sensitivity and specificity of RDTs during routine use for malaria case management in peripheral health facilities. From December 2007 to October 2008, HRP2-based ParaHIT-f RDTs were introduced in 12 facilities without available microscopy in Rufiji District, Tanzania. Health workers received a single day of instruction on how to perform an RDT and thick blood smear. Job aids, Integrated Management of Childhood Illness guidelines, and national malaria treatment algorithms were reviewed. For quality assurance (QA), thick blood smears for reference microscopy were collected for 2 to 3 days per week from patients receiving RDTs; microscopy was not routinely performed at the health facilities. Slides were stained and read centrally within 72 hours of collection by a reference microscopist. When RDT and blood smear results were discordant, blood smears were read by additional reference microscopists blinded to earlier results. Facilities were supervised monthly by the district laboratory supervisor or a member of the study team. Ten thousand six hundred fifty (10,650) patients were tested with RDTs, and 51.5% (5,488/10,650) had a positive test result. Blood smear results were available for 3,914 patients, of whom 40.1% (1,577/3,914) were positive for P. falciparum malaria. Overall RDT sensitivity was 90.7% (range by facility 85.7–96.5%) and specificity was 73.5% (range 50.0–84.3%). Sensitivity increased with increasing parasite density. Successful implementation of RDTs was achieved in peripheral health facilities with adequate training and supervision. Quality assurance is essential to the adequate performance of any laboratory test. Centralized staining and reading of blood smears provided useful monitoring of RDT performance. However, this level of QA may not be sustainable nationwide. PMID:20065013

  3. 40 CFR 792.49 - Laboratory operation areas.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 32 2011-07-01 2011-07-01 false Laboratory operation areas. 792.49... CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.49 Laboratory operation areas. Separate laboratory space and other space shall be provided, as needed, for the performance of the routine...

  4. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation)

    PubMed Central

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-01-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists. PMID:25336760

  5. Clinical Chemistry Laboratory Automation in the 21st Century - Amat Victoria curam (Victory loves careful preparation).

    PubMed

    Armbruster, David A; Overcash, David R; Reyes, Jaime

    2014-08-01

    The era of automation arrived with the introduction of the AutoAnalyzer using continuous flow analysis and the Robot Chemist that automated the traditional manual analytical steps. Successive generations of stand-alone analysers increased analytical speed, offered the ability to test high volumes of patient specimens, and provided large assay menus. A dichotomy developed, with a group of analysers devoted to performing routine clinical chemistry tests and another group dedicated to performing immunoassays using a variety of methodologies. Development of integrated systems greatly improved the analytical phase of clinical laboratory testing and further automation was developed for pre-analytical procedures, such as sample identification, sorting, and centrifugation, and post-analytical procedures, such as specimen storage and archiving. All phases of testing were ultimately combined in total laboratory automation (TLA) through which all modules involved are physically linked by some kind of track system, moving samples through the process from beginning-to-end. A newer and very powerful, analytical methodology is liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS). LC-MS/MS has been automated but a future automation challenge will be to incorporate LC-MS/MS into TLA configurations. Another important facet of automation is informatics, including middleware, which interfaces the analyser software to a laboratory information systems (LIS) and/or hospital information systems (HIS). This software includes control of the overall operation of a TLA configuration and combines analytical results with patient demographic information to provide additional clinically useful information. This review describes automation relevant to clinical chemistry, but it must be recognised that automation applies to other specialties in the laboratory, e.g. haematology, urinalysis, microbiology. It is a given that automation will continue to evolve in the clinical laboratory, limited only by the imagination and ingenuity of laboratory scientists.

  6. Impact of clinical awareness and diagnostic tests on the underdiagnosis of Clostridium difficile infection.

    PubMed

    Alcalá, L; Reigadas, E; Marín, M; Martín, A; Catalán, P; Bouza, E

    2015-08-01

    A multicenter study of Clostridium difficile infection (CDI) performed during 2008 in Spain revealed that two of every three episodes went undiagnosed or were misdiagnosed owing to nonsensitive diagnostic tests or lack of clinical suspicion and request. Since then, efforts have been made to improve the diagnostic tests used by laboratories and to increase the awareness of this disease among both clinicians and microbiologists. Our objective was to evaluate the impact of these efforts by assessing the current magnitude of underdiagnosis of CDI in Spain using two point-prevalence studies performed on one day each in January and July of 2013. A total of 111 Spanish laboratories selected all unformed stool specimens received for microbiological diagnosis on these days, and toxigenic culture was performed at a central reference laboratory. Toxigenic isolates were characterized both pheno- and genotypically. The reference laboratory detected 103 episodes of CDI in patients aged 2 years or more. Half (50.5 %) of the episodes were not diagnosed in the participating laboratories, owing to insensitive diagnostic tests (15.5 %) or the lack of clinical suspicion and request (35.0 %). The main ribotypes were 014, 078/126, 001/072, and 106. Ribotype 027 caused 2.9 % of all cases. Despite all the interventions undertaken, CDI remains a highly neglected disease because of the lack of sensitive diagnostic tests in some institutions and, especially, the absence of clinical suspicion, mainly in patients with community-associated CDI. Toxigenic C. difficile should be routinely sought in unformed stools sent for microbiological diagnosis, regardless of their origin.

  7. External quality assessment for laboratory testing of HLA-B*15:02 allele in relation to carbamazepine therapy.

    PubMed

    Lin, Guigao; Zhang, Kuo; Han, Yanxi; Xie, Jiehong; Li, Jinming

    2018-02-01

    Due to the significant risk of developing Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN), the use of carbamazepine is not recommended in patients carrying the human leukocyte antigen B (HLA-B) *15:02 allele. In an effort to guarantee reliable community-based HLA-B*15:02 testing throughout China, a HLA-B*15:02 genotyping external quality assessment (EQA) program was set up. In 2016, 10 genomic DNA samples with known HLA-B*15:02 allele status were sent to 37 laboratories from 16 provinces with a request for routine HLA-B*15:02 screening. The samples were validated using Sanger sequencing by a reference laboratory. Both genotyping results and clinical written reports were evaluated. Thirty-six of the participating laboratories correctly identified the HLA-B*15:02 allele status for all EQA samples. However, one lab failed to identify any positive challenges. The overall analytical sensitivity was 97.3% (180/185 challenges; 95% confidence interval: 93.8%-99.1%) and the analytic specificity was 100% (185/185; 95% confidence interval: 98.0%-100%). A review of the written reports showed that the clinical reporting for HLA-B*15:02 detection should be improved. Some essential information was missing, most notably laboratory information/contact, therapeutic recommendations, and methodology. External quality assessment is valuable in assessing and improving the quality of laboratory testing of HLA-B*15:02 allele. © 2017 Wiley Periodicals, Inc.

  8. Generic System for Remote Testing and Calibration of Measuring Instruments: Security Architecture

    NASA Astrophysics Data System (ADS)

    Jurčević, M.; Hegeduš, H.; Golub, M.

    2010-01-01

    Testing and calibration of laboratory instruments and reference standards is a routine activity and is a resource and time consuming process. Since many of the modern instruments include some communication interfaces, it is possible to create a remote calibration system. This approach addresses a wide range of possible applications and permits to drive a number of different devices. On the other hand, remote calibration process involves a number of security issues due to recommendations specified in standard ISO/IEC 17025, since it is not under total control of the calibration laboratory personnel who will sign the calibration certificate. This approach implies that the traceability and integrity of the calibration process directly depends on the collected measurement data. The reliable and secure remote control and monitoring of instruments is a crucial aspect of internet-enabled calibration procedure.

  9. Performance indicators and decision making for outsourcing public health laboratory services.

    PubMed

    Santos, Maria Angelica Borges dos; Moraes, Ricardo Montes de; Passos, Sonia Regina Lambert

    2012-06-01

    To develop performance indicators for outsourcing clinical laboratory services, based on information systems and public administrative records. In the municipality of Rio de Janeiro, Southern Brazil, the public health laboratory network comprised 33 laboratories with automated equipment (but no integrated information system), 90 primary care units (where sample collection was performed) and 983 employees. Information records were obtained from the administrative records of the Budget Information System for Public Health and the Outpatient and Hospital Information System of the Unified Health System. Performance indicators (production, productivity, usage and costs) were generated from data collected routinely from 2006 to 2008. The variations in production, costs and unit prices for tests were analyzed by Laspeyres and Paasche indices, which specifically measure laboratory activity, and by the Consumer Price Index from the Brazilian Institute of Geography and Statistics. A total of 10,359,111 tests were performed in 2008 (10.6% increase over 2006), and the test/employee ratio grew by 8.6%. The costs of supplies, wages and providers increased by 2.3%, 45.4% and 18.3%, respectively. The laboratory tests per visit and hospitalizations increased by 10% and 20%, respectively. The direct costs totaled R$ 63.2 million in 2008, representing an increase of 22.2% in current values during the period analyzed. The direct costs deflated by the Brazilian National Consumer Price Index (9.5% for the period) showed an 11.6% increase in production volumes. The activity-specific volume index, which considers changes in the mix of tests, showed increases of 18.5% in the test price and 3.1% in the production volume. The performance indicators, particularly the specific indices for volume and price of activity, constitute a baseline of performance potential for monitoring private laboratories and contractors. The economic performance indicators demonstrated the need for network information system integration prior to an outsourcing decision.

  10. The Italian pilot external quality assessment program for cystic fibrosis sweat test.

    PubMed

    Salvatore, Marco; Floridia, Giovanna; Amato, Annalisa; Censi, Federica; Carta, Claudio; de Stefano, Maria Chiara; Ferrari, Gianluca; Tosto, Fabrizio; Capoluongo, Ettore; Caruso, Ubaldo; Castaldo, Giuseppe; Cirilli, Natalia; Corbetta, Carlo; Padoan, Rita; Raia, Valeria; Taruscio, Domenica

    2016-05-01

    Sweat chloride test is the gold standard test for cystic fibrosis (CF) diagnosis. In 2014 the Istituto Superiore di Sanità established the Italian pilot external quality assessment program for CF sweat test (IEQA-ST). Ten laboratories, included among the 33 Italian CF Referral Centers, were selected and enrolled on the basis of their attitude to perform sweat test (ST) analysis by using methods recommended by the Italian Guidelines. They received three different sweat-like samples (normal, borderline and pathologic chloride concentration), with mock clinical indications, for analysis according to routine procedures. Assessment, performed by a panel of experts, covered analytical performance, interpretation and reporting of results; categories of "poor" and "satisfactory" performance were not defined. All data were managed through a web utility. The program identified important areas of interest and, in some case, of concern. It is important to underline that results are referred to a small proportion, i.e. about 30%, of Italian laboratories performing CF ST in the context of the Referral Centers. Data collected highlight the importance of participation in EQA programs as it may improve laboratory/clinical performance; our study represents a model for the setting up of a large-scale EQA scheme for ST. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Scaling up HIV viral load - lessons from the large-scale implementation of HIV early infant diagnosis and CD4 testing.

    PubMed

    Peter, Trevor; Zeh, Clement; Katz, Zachary; Elbireer, Ali; Alemayehu, Bereket; Vojnov, Lara; Costa, Alex; Doi, Naoko; Jani, Ilesh

    2017-11-01

    The scale-up of effective HIV viral load (VL) testing is an urgent public health priority. Implementation of testing is supported by the availability of accurate, nucleic acid based laboratory and point-of-care (POC) VL technologies and strong WHO guidance recommending routine testing to identify treatment failure. However, test implementation faces challenges related to the developing health systems in many low-resource countries. The purpose of this commentary is to review the challenges and solutions from the large-scale implementation of other diagnostic tests, namely nucleic-acid based early infant HIV diagnosis (EID) and CD4 testing, and identify key lessons to inform the scale-up of VL. Experience with EID and CD4 testing provides many key lessons to inform VL implementation and may enable more effective and rapid scale-up. The primary lessons from earlier implementation efforts are to strengthen linkage to clinical care after testing, and to improve the efficiency of testing. Opportunities to improve linkage include data systems to support the follow-up of patients through the cascade of care and test delivery, rapid sample referral networks, and POC tests. Opportunities to increase testing efficiency include improvements to procurement and supply chain practices, well connected tiered laboratory networks with rational deployment of test capacity across different levels of health services, routine resource mapping and mobilization to ensure adequate resources for testing programs, and improved operational and quality management of testing services. If applied to VL testing programs, these approaches could help improve the impact of VL on ART failure management and patient outcomes, reduce overall costs and help ensure the sustainable access to reduced pricing for test commodities, as well as improve supportive health systems such as efficient, and more rigorous quality assurance. These lessons draw from traditional laboratory practices as well as fields such as logistics, operations management and business. The lessons and innovations from large-scale EID and CD4 programs described here can be adapted to inform more effective scale-up approaches for VL. They demonstrate that an integrated approach to health system strengthening focusing on key levers for test access such as data systems, supply efficiencies and network management. They also highlight the challenges with implementation and the need for more innovative approaches and effective partnerships to achieve equitable and cost-effective test access. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  12. Identification of Streptococcus pyogenes - Phenotypic Tests vs Molecular Assay (spy1258PCR): A Comparative Study.

    PubMed

    Abraham, Tintu; Sistla, Sujatha

    2016-07-01

    Traditionally Group A Streptococcus pyogenes (GAS) is differentiated from other beta haemolytic streptococci (BHS) by certain presumptive tests such as bacitracin sensitivity and production of Pyrollidonyl Aryl Sulfatase (PYR). The phenotypic and genotypic confirmatory tests are Lancefield grouping for cell wall carbohydrate antigen and PCR for spy1258 gene respectively. Reliance on presumptive tests alone may lead to misidentification of isolates. To compare the predictive values of routine phenotypic tests with spy1258 PCR for the identification of Streptococcus pyogenes. This comparative analytical study was carried out in the Department of Microbiology, JIPMER, Puducherry, over a period of 18 months (1(st) November 2013 to 30(th) April 2015). Two hundred and six consecutive BHS isolates from various clinical samples were subjected to phenotypic tests such as bacitracin sensitivity, PYR test and Lancefield grouping. The results were compared with spy1258 PCR which was considered 95 the confirmatory test for identification. The sensitivity and specificity of phenotypic tests were as follows; Susceptibility to bacitracin - 95.42%, 70.96%, PYR test - 95.42%, 77.41%, Lancefield grouping- 97.71%, 80.64%. Clinical laboratories should not depend on bacitracin sensitivity as a single presumptive test for the routine identification of GAS but should use supplemental tests such as PYR test or latex agglutination test and for best results use spy1258 PCR.

  13. A Rare Case of Cerebellar Ataxia Due to Voltage-Gated Calcium Channel and Glutamic Acid Decarboxylase Autoantibodies.

    PubMed

    Annunziata, Giuseppe; Lobo, Pamela; Carbuccia, Cristian

    2017-11-27

    BACKGROUND Autoimmune cerebellar ataxia can be paraneoplastic in nature or can occasionally present without evidence of an ongoing malignancy. The detection of specific autoantibodies has been statistically linked to different etiologies. CASE REPORT A 55-year-old African-American woman with hypertension and a past history of morbid obesity and uncontrolled diabetes status post gastric bypass four years prior to the visit (with significantly improved body mass index and hemoglobin A1c controlled at the time of the clinical encounter) presented to the office complaining of gradual onset of unsteadiness and recurrent falls for the past three years, as well as difficulties coordinating routine daily activities. The neurologic exam showed moderate dysarthria and ataxic gait with bilateral dysmetria and positive Romberg test. Routine laboratory test results were only remarkable for a mild elevation of erythrocyte sedimentation rate, and most laboratory and imaging tests for common causes of ataxia failed to demonstrate an etiology. Upon further workup, evidence of anti-voltage-gated calcium channel and anti-glutamic acid decarboxylase antibody was demonstrated. She was then treated with intravenous immunoglobulins with remarkable clinical improvement. CONCLUSIONS We present a case of antibody-mediated ataxia not associated with malignancy. While ataxia is rarely related to autoantibodies, in such cases it is critical to understand the etiology of this disabling condition in order to treat it correctly. Clinicians should be aware of the possible association with specific autoantibodies and the necessity to rule out an occult malignancy in such cases.

  14. [Use of stimulants and drugs of abuse in sport: the Italian experience].

    PubMed

    Strano Rossi, Sabina; Abate, Maria Gabriella; Braganò, Maria Cristina; Botrè, Francesco

    2009-01-01

    The incidence of the abuse of illicit drugs in sport may be a useful indicator of the extent of the phenomenon among the youth population. Many drugs of abuse are included in the WADA (World Anti-Doping Agency) Prohibited List, and are therefore routinely tested for in antidoping controls. This study presents the data obtained in tests carried out in the period 2003- 2007 at the Antidoping Laboratory of Rome, on 44781 samples analysed. The methods used are those developed by the Laboratory for routine antidoping analyses. The percentage of positive test results ranges from 1.1 to 2%, with a high incidence of stimulants and drugs of abuse. The substance most frequently found is THC metabolite, which accounts for 0.2-0.4% of the total, followed by cocaine metabolites, accounting for 0.1%. Other stimulants found are ephedrines, carphedon, modafinil, and anorexic compounds such as phendimetrazine and norfenfluramine. No amphetamines or amphetaminelike designer drugs have been detected. These data may be indicative of the widespread incidence of cocaine and cannabis abuse among the young Italian population, bearing in mind that the phenomenon is underestimated in this study, due to the fact that drugs of abuse are investigated only in samples involved in competitive sport, and especially to the fact that people doing such activities take more care of their health and are subject to greater control in their behaviour and habits with respect to the 'normal' population.

  15. Acquired neuropathies.

    PubMed

    Lozeron, Pierre; Trocello, Jean-Marc; Kubis, Nathalie

    2013-09-01

    Acquired neuropathies represent most of the neuropathies encountered in clinical practice. Hundreds of causes have been identified even though up to 41% of patients are still classified as idiopathic (Rajabally and Shah in J Neurol 258:1431-1436, 1). Routine evaluation relies on comprehensive medical history taking, clinical examination, nerve conduction studies and laboratory tests. Other investigations such as nerve biopsy or nerve or muscle imaging are performed in specific settings. This review focuses on recent advances in acquired neuropathies.

  16. Public health facility resource availability and provider adherence to first antenatal guidelines in a low resource setting in Accra, Ghana.

    PubMed

    Amoakoh-Coleman, Mary; Agyepong, Irene Akua; Kayode, Gbenga A; Grobbee, Diederick E; Klipstein-Grobusch, Kerstin; Ansah, Evelyn K

    2016-09-21

    Lack of resources has been identified as a reason for non-adherence to clinical guidelines. Our aim was to describe public health facility resource availability in relation to provider adherence to first antenatal visit guidelines. A cross-sectional analysis of the baseline data of a prospective cohort study on adherence to first antenatal care visit guidelines was carried out in 11 facilities in the Greater Accra Region of Ghana. Provider adherence was studied in relation to health facility resource availability such as antenatal workload for clinical staffs, routine antenatal drugs, laboratory testing, protocols, ambulance and equipment. Eleven facilities comprising 6 hospitals (54.5 %), 4 polyclinics (36.4 %) and 1 health center were randomly sampled. Complete provider adherence to first antenatal guidelines for all the 946 participants was 48.1 % (95 % CI: 41.8-54.2 %), varying significantly amongst the types of facilities, with highest rate in the polyclinics. Average antenatal workload per month per clinical staff member was higher in polyclinics compared to the hospitals. All facility laboratories were able to conduct routine antenatal tests. Most routine antenatal drugs were available in all facilities except magnesium sulphate and sulphadoxine-pyrimethamine which were lacking in some. Antenatal service protocols and equipment were also available in all facilities. Although antenatal workload varies across different facility types in the Greater Accra region, other health facility resources that support implementation of first antenatal care guidelines are equally available in all the facilities. These factors therefore do not adequately account for the low and varying proportions of complete adherence to guidelines across facility types. Providers should be continually engaged for a better understanding of the barriers to their adherence to these guidelines.

  17. Cell Line Controls for the Genotyping of a Spectrum of Human Single Nucleotide Polymorphisms in the Clinical Laboratory.

    PubMed

    Kimbacher, Christine; Paar, Christian; Freystetter, Andrea; Berg, Joerg

    2018-05-01

    Genotyping for clinically important single nucleotide polymorphisms (SNPs) is performed by many clinical routine laboratories. To support testing, quality controls and reference materials are needed. Those may be derived from residual patient samples, left over samples of external quality assurance schemes, plasmid DNA or DNA from cell lines. DNAs from cell lines are commutable and available in large amounts. DNA from 38 cell lines were examined for suitability as controls in 11 SNP assays that are frequently used in a clinical routine laboratory: FV (1691G>A), FII (20210G>A), PAI-1 4G/5G polymorphism, MTHFR (677C>T, 1298A>C), HFE (H63D, S65C, C282Y), APOE (E2, E3, E4), LPH (-13910C>T), UGT1A1 (*28, *36, *37), TPMT (*2, *3A, *3B, *3C), VKORC1 (-1639G>A, 1173C>T), CYP2C9 (*2, *3, *5). Genotyping was performed by real-time PCR with melting curve analysis and confirmed by bi-directional sequencing. We find an almost complete spectrum of genotypic constellations within these 38 cell lines. About 12 cell lines appear sufficient as genotypic controls for the 11 SNP assays by covering almost all of the genotypes. However, hetero- and homozygous genotypes for FII and the alleles TPMT*2, UGT1A1*37 and CYP2C9*5 were not detected in any of the cell lines. DNA from most of the examined cell lines appear suitable as quality controls for these SNP assays in the laboratory routine, as to the implementation of those assays or to prepare samples for quality assurance schemes. Our study may serve as a pilot to further characterize these cell lines to arrive at the status of reference materials.

  18. Intra- and interlaboratory variability in acute toxicity tests with glochidia and juveniles of freshwater mussels (Unionidae)

    USGS Publications Warehouse

    Wang, N.; Augspurger, T.; Barnhart, M.C.; Bidwell, Joseph R.; Cope, W.G.; Dwyer, F.J.; Geis, S.; Greer, I.E.; Ingersoll, C.G.; Kane, C.M.; May, T.W.; Neves, R.J.; Newton, T.J.; Roberts, A.D.; Whites, D.W.

    2007-01-01

    The present study evaluated the performance and variability in acute toxicity tests with glochidia and newly transformed juvenile mussels using the standard methods outlined in American Society for Testing and Materials (ASTM). Multiple 48-h toxicity tests with glochidia and 96-h tests with juvenile mussels were conducted within a single laboratory and among five laboratories. All tests met the test acceptability requirements (e.g., ???90% control survival). Intralaboratory tests were conducted over two consecutive mussel-spawning seasons with mucket (Actinonaias ligamentina) or fatmucket (Lampsilis siliquoidea) using copper, ammonia, or chlorine as a toxicant. For the glochidia of both species, the variability of intralaboratory median effective concentrations (EC50s) for the three toxicants, expressed as the coefficient of variation (CV), ranged from 14 to 27% in 24-h exposures and from 13 to 36% in 48-h exposures. The intralaboratory CV of copper EC50s for juvenile fatmucket was 24% in 48-h exposures and 13% in 96-h exposures. Interlaboratory tests were conducted with fatmucket glochidia and juveniles by five laboratories using copper as a toxicant. The interlaboratory CV of copper EC50s for glochidia was 13% in 24-h exposures and 24% in 48-h exposures, and the interlaboratory CV for juveniles was 22% in 48-h exposures and 42% in 96-h exposures. The high completion success and the overall low variability in test results indicate that the test methods have acceptable precision and can be performed routinely. ?? 2007 SETAC.

  19. Integrated DNA walking system to characterize a broad spectrum of GMOs in food/feed matrices.

    PubMed

    Fraiture, Marie-Alice; Herman, Philippe; Lefèvre, Loic; Taverniers, Isabel; De Loose, Marc; Deforce, Dieter; Roosens, Nancy H

    2015-08-14

    In order to provide a system fully integrated with qPCR screening, usually used in GMO routine analysis, as well as being able to detect, characterize and identify a broad spectrum of GMOs in food/feed matrices, two bidirectional DNA walking methods targeting p35S or tNOS, the most common transgenic elements found in GM crops, were developed. These newly developed DNA walking methods are completing the previously implemented DNA walking method targeting the t35S pCAMBIA element. Food/feed matrices containing transgenic crops (Bt rice or MON863 maize) were analysed using the integrated DNA walking system. First, the newly developed DNA walking methods, anchored on the sequences used for the p35S or tNOS qPCR screening, were tested on Bt rice that contains these two transgenic elements. Second, the methods were assessed on a maize sample containing a low amount of the GM MON863 event, representing a more complex matrix in terms of genome size and sensitivity. Finally, to illustrate its applicability in GMO routine analysis by enforcement laboratories, the entire workflow of the integrated strategy, including qPCR screening to detect the potential presence of GMOs and the subsequent DNA walking methods to characterize and identify the detected GMOs, was applied on a GeMMA Scheme Proficiency Test matrix. Via the characterization of the transgene flanking region between the transgenic cassette and the plant genome as well as of a part of the transgenic cassette, the presence of GMOs was properly confirmed or infirmed in all tested samples. Due to their simple procedure and their short time-frame to get results, the developed DNA walking methods proposed here can be easily implemented in GMO routine analysis by the enforcement laboratories. In providing crucial information about the transgene flanking regions and/or the transgenic cassettes, this DNA walking strategy is a key molecular tool to prove the presence of GMOs in any given food/feed matrix.

  20. Cyclophosphamide administration routine in autoimmune rheumatic diseases: a review.

    PubMed

    Teles, Kaian Amorim; Medeiros-Souza, Patricia; Lima, Francisco Aires Correa; Araújo, Bruno Gedeon de; Lima, Rodrigo Aires Correa

    Cyclophosphamide is an alkylating agent widely used for the treatment of malignant neoplasia and which can be used in the treatment of multiple rheumatic diseases. Medication administration errors may lead to its reduced efficacy or increased drug toxicity. Many errors occur in the administration of injectable drugs. The present study aimed at structuring a routine for cyclophosphamide use, as well as creating a document with pharmacotherapeutic guidelines for the patient. The routine is schematized in three phases: pre-chemotherapy, administration of cyclophosphamide, and post-chemotherapy, taking into account the drugs to be administered before and after cyclophosphamide in order to prevent adverse effects, including nausea and hemorrhagic cystitis. Adverse reactions can alter laboratory tests; thus, this routine included clinical management for changes in white blood cells, platelets, neutrophils, and sodium, including cyclophosphamide dose adjustment in the case of kidney disease. Cyclophosphamide is responsible for other rare - but serious - side effects, for instance, hepatotoxicity, severe hyponatremia and heart failure. Other adverse reactions include hair loss, amenorrhea and menopause. In this routine, we also entered guidelines to post-chemotherapy patients. The compatibility of injectable drugs with the vehicle used has been described, as well as stability and infusion times. The routine aimed at the rational use of cyclophosphamide, with prevention of adverse events and relapse episodes, factors that may burden the health care system. Copyright © 2016 Elsevier Editora Ltda. All rights reserved.

  1. Routine sputum culture

    MedlinePlus

    Sputum culture ... There, it is placed in a special dish (culture). It is then watched to see if bacteria ... Elsevier; 2018:chap 36. Chernecky CC, Berger BJ. Culture, routine. In: Chernecky CC, Berger BJ, eds. Laboratory ...

  2. Physician satisfaction with clinical laboratory services: a College of American Pathologists Q-probes study of 138 institutions.

    PubMed

    Jones, Bruce A; Bekeris, Leonas G; Nakhleh, Raouf E; Walsh, Molly K; Valenstein, Paul N

    2009-01-01

    Monitoring customer satisfaction is a valuable component of a laboratory quality improvement program. To survey the level of physician satisfaction with hospital clinical laboratory services. Participating institutions provided demographic and practice information and survey results of physician satisfaction with defined aspects of clinical laboratory services, rated on a scale of 1 (poor) to 5 (excellent). One hundred thirty-eight institutions participated in this study and submitted a total of 4329 physician surveys. The overall satisfaction score for all institutions ranged from 2.9 to 5.0. The median overall score for all participants was 4.1 (10th percentile, 3.6; 90th percentile, 4.5). Physicians were most satisfied with the quality/reliability of results and staff courtesy, with median values of excellent or good ratings of 89.9%. Of the 5 service categories that received the lowest percentage values of excellent/good ratings (combined scores of 4 and 5), 4 were related to turnaround time for inpatient stat, outpatient stat, routine, and esoteric tests. Surveys from half of the participating laboratories reported that 96% to 100% of physicians would recommend the laboratory to other physicians. The category most frequently selected as the most important category of laboratory services was quality/reliability of results (31.7%). There continues to be a high level of physician satisfaction and loyalty with clinical laboratory services. Test turnaround times are persistent categories of dissatisfaction and present opportunities for improvement.

  3. Preconception risk assessment of infertile couples

    PubMed Central

    Nekuei, Nafisehsadat; Kazemi, Ashraf; Ehsanpur, Soheila; Beigi, Nastaran Mohammad Ali

    2013-01-01

    Background: With regard to the importance of preconception conditions in maternal health and fertility, preconception risk assessment makes treatment trends and pregnancy outcome more successful among infertile couples. This study has tried to investigate preconception risk assessment in infertile couples. Materials and Methods: This is a descriptive analytical survey conducted on 268 subjects, selected by convenient sampling, referring to Isfahan infertility centers (Iran). The data were collected by questionnaires through interview and clients’ medical records. Pre-pregnancy risk assessment including history taking (personal, familial, medical, medications, menstruation, and pregnancy), exams (physical, genital, and vital signs), and routine test requests (routine, cervix, infections, and biochemical tests) was performed in the present study. Results: The results showed that the lowest percentage of taking a complete history was for personal history (0.4%) and the highest was for history of menstruation (100%). The lowest percentage of complete exam was for physical exam (3.4%) and the highest for genital exam (100%). With regard to laboratory assessment, the highest percentage was for routine tests (36.6%) and the lowest was for infection tests (0.4%). Conclusion: Based o the results of the present study, most of the risk assessment components are poorly assessed in infertile couples. With regard to the importance of infertility treatment, spending high costs and time on that, and existence of high-risk individuals as well as treatment failures, health providers should essentially pay special attention to preconception risk assessment in infertile couples in order to enhance the chance of success and promote treatment outcome. PMID:23983724

  4. Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

    PubMed

    Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H

    2016-12-01

    In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Diagnostic trends in Clostridium difficile detection in Finnish microbiology laboratories.

    PubMed

    Könönen, Eija; Rasinperä, Marja; Virolainen, Anni; Mentula, Silja; Lyytikäinen, Outi

    2009-12-01

    Due to increased interest directed to Clostridium difficile-associated infections, a questionnaire survey of laboratory diagnostics of toxin-producing C. difficile was conducted in Finland in June 2006. Different aspects pertaining to C. difficile diagnosis, such as requests and criteria used for testing, methods used for its detection, yearly changes in diagnostics since 1996, and the total number of investigations positive for C. difficile in 2005, were asked in the questionnaire, which was sent to 32 clinical microbiology laboratories, including all hospital-affiliated and the relevant private clinical microbiology laboratories in Finland. The situation was updated by phone and email correspondence in September 2008. In June 2006, 28 (88%) laboratories responded to the questionnaire survey; 24 of them reported routinely testing requested stool specimens for C. difficile. Main laboratory methods included toxin detection (21/24; 88%) and/or anaerobic culture (19/24; 79%). In June 2006, 18 (86%) of the 21 laboratories detecting toxins directly from feces, from the isolate, or both used methods for both toxin A (TcdA) and B (TcdB), whereas only one laboratory did so in 1996. By September 2008, all of the 23 laboratories performing diagnostics for C. difficile used methods for both TcdA and TcdB. In 2006, the number of specimens processed per 100,000 population varied remarkably between different hospital districts. In conclusion, culturing C. difficile is common and there has been a favorable shift in toxin detection practice in Finnish clinical microbiology laboratories. However, the variability in diagnostic activity reported in 2006 creates a challenge for national monitoring of the epidemiology of C. difficile and related diseases.

  6. Detection of Carbapenemase Production in a Collection of Enterobacteriaceae with Characterized Resistance Mechanisms from Clinical and Environmental Origins by Use of Both Carba NP and Blue-Carba Tests.

    PubMed

    García-Fernández, Sergio; Morosini, María-Isabel; Gijón, Desirèe; Beatobe, Lorena; Ruiz-Garbajosa, Patricia; Domínguez, Lucas; Cantón, Rafael; Valverde, Aránzazu

    2016-02-01

    Rapid-screening methods to confirm the presence of resistance mechanisms in multidrug-resistant bacteria are currently recommended. Carba NP and Blue-Carba tests were evaluated in carbapenemase-producing Enterobacteriaceae from hospital (n = 102) and environmental (n = 57) origins for detecting the different molecular classes among them. Both methods showed to be fast and cost-effective, with high sensitivity (98% to 100%) and specificity (100%), and may be easily introduced in the routine laboratory. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  7. Multicenter Comparison of the Etest and EUCAST Methods for Antifungal Susceptibility Testing of Candida Isolates to Micafungin

    PubMed Central

    Bougnoux, M.-E.; Accoceberry, I.; Angoulvant, A.; Bailly, E.; Botterel, F.; Chevrier, S.; Chouaki, T.; Dalle, F.; Datry, A.; Dupuis, A.; Fekkar, A.; Gangneux, J. P.; Guitard, J.; Hennequin, C.; Le Govic, Y.; Le Pape, P.; Maubon, D.; Sautour, M.; Sendid, B.; Chandenier, J.

    2016-01-01

    In vitro susceptibility of 933 Candida isolates, from 16 French hospitals, to micafungin was determined using the Etest in each center. All isolates were then sent to a single center for determination of MICs by the EUCAST reference method. Overall essential agreement between the two tests was 98.5% at ±2 log2 dilutions and 90.2% at ±1 log2 dilutions. Categorical agreement was 98.2%. The Etest is a valuable alternative to EUCAST for the routine determination of micafungin MICs in medical mycology laboratories. PMID:27297480

  8. Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing.

    PubMed

    Whiley, Harriet

    2016-12-24

    Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups.

  9. Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing

    PubMed Central

    Whiley, Harriet

    2016-01-01

    Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups. PMID:28029126

  10. [Status of the clinical laboratory in the mandatory postgraduate medical training system. (1) Report from a laboratory technologist].

    PubMed

    Nishikawa, Yoko

    2006-06-01

    According to a new system for postgraduate clinical training, 33 medical trainees have been accepted for the past two years at Osaka General Medical Center. Before practicing clinical medicine in each division by a super-rotated table, orientation is scheduled for 5 days to master the basic systems indispensable to the hospital. In this orientation, training in laboratory medicine is performed for 7 hours (3.5 hours for 2 days). Trainees are divided into 4 groups and learn emergency tests of chemistry, hematology and urinalysis, blood transfusion, physiology and microbiology for 60 min each. Laboratory technologists instruct the trainees to gain the basic skills. The main contents are blood gas measuring in chemistry, sample preparation in hematology and urinalysis, taking each other's ECG, ordering blood products for transfusion, serologic study of infectious diseases, and Gram stain in microbiology. Although it is difficult to find time for routine analysis and instructing trainees in the clinical laboratory, it is a suitable opportunity for revision, also for laboratory technologists, and for communication to discuss clinical matters.

  11. Burkholderia pseudomallei: Challenges for the Clinical Microbiology Laboratory.

    PubMed

    Hemarajata, Peera; Baghdadi, Jonathan D; Hoffman, Risa; Humphries, Romney M

    2016-12-01

    Melioidosis is a potentially fatal infection caused by the bacterium Burkholderia pseudomallei Clinical diagnosis of melioidosis can be challenging since there is no pathognomonic clinical syndrome, and the organism is often misidentified by methods used routinely in clinical laboratories. Although the disease is more prevalent in Thailand and northern Australia, sporadic cases may be encountered in areas where it is not endemic, including the United States. Since the organism is considered a tier 1 select agent according to the Centers for Disease Control and Prevention and the U.S. Department of Agriculture Animal and Plant Health Inspection Service, clinical laboratories must be proficient at rapidly recognizing isolates suspicious for B. pseudomallei, be able to safely perform necessary rule-out tests, and to refer suspect isolates to Laboratory Response Network reference laboratories. In this minireview, we report a case of melioidosis encountered at our institution and discuss the laboratory challenges encountered when dealing with clinical isolates suspicious for B. pseudomallei or clinical specimens from suspected melioidosis cases. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. Interlaboratory study of a liquid chromatography method for erythromycin: determination of uncertainty.

    PubMed

    Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J

    2003-08-22

    Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.

  13. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    PubMed

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  14. Effect of Acupuncture on Body Weight Reduction and Inflammatory Mediators in Egyptian Obese Patients

    PubMed Central

    Ismail, Laila Ahmed Abou; Ibrahim, Alshaymaa Ahmed; Abdel-Latif, Ghada A.; El-Haleem, Dalia Adel Abd; Helmy, Ghada; Labib, Lylah M.; El-Masry, M. Kadry

    2015-01-01

    AIM: Aim of this study was to examine the effectiveness of body acupuncture on body weight loss, routine laboratory tests and pro-inflammatory markers. METHODOLOGY: The study was performed on eighty obese patients. They were divided into three groups according to their body mass index. Subjects received acupuncture for three- six months in combination with a low-calorie diet. They were assessed pre and post acupuncture, by anthropometric measurement, routine laboratory tests and, tumor necrosis factor- alpha (TNF-α), interleukin- 6 (IL-6), and high sensitivity C-reactive protein (hsCRP) levels in serum. RESULTS: The pre-acupuncture results showed significant difference between the three grades of obesity and the controls regarding TNFα, IL-6 and hsCRP. We found significant reduction in anthropometric measurement of adiposity after acupuncture. In comparing the pre &post acupuncture results of TNF-α, IL-6 and hsCRP showed high significant reduction after acupuncture. There are highly significant decrease in kidney function (creatinine and uric acid) and lipid profile (cholesterol and triglycerides) and fasting blood glucose, but there was no significant difference in urea, SGPT, SGOT, HDL and LDL. CONCLUSION: Body acupuncture in combination with diet restriction was found to be effective for weight loss and also reduction of the inflammatory reactions. Acupuncture could be used as a synergistic treatment option for obesity control. PMID:27275202

  15. Sequim Marine Research Laboratory routine environmental measurements during CY-1976

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fix, J.J.; Blumer, P.J.

    1977-05-01

    Beginning in 1976, a routine environmental program was established at the Marine Research Laboratory (MRL) at Sequim, Washington. The program is designed, primarily, to determine levels of radioactivity present in selected biota in Sequim Bay. The biota were selected because of their presence near the laboratory and their capacity to concentrate trace elements. Other samples were obtained to determine the radionuclides in Sequim Bay and laboratory drinking water, as well as the ambient radiation exposure levels and surface deposition of fallout radionuclides for the laboratory area. A summary of the analytical methods used is included. The present document includes datamore » obtained during CY 1976, the first year of the program. Radionuclides present in samples are attributed to fallout. Data are included on content of oil and Cu in seawater samples.« less

  16. Automated acquisition system for routine, noninvasive monitoring of physiological data.

    PubMed

    Ogawa, M; Tamura, T; Togawa, T

    1998-01-01

    A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.

  17. Clinicians' interpretations of point of care urine culture versus laboratory culture results: analysis from the four-country POETIC trial of diagnosis of uncomplicated urinary tract infection in primary care.

    PubMed

    Hullegie, Saskia; Wootton, Mandy; Verheij, Theo J M; Thomas-Jones, Emma; Bates, Janine; Hood, Kerenza; Gal, Micaela; Francis, Nick A; Little, Paul; Moore, Michael; Llor, Carl; Pickles, Timothy; Gillespie, David; Kirby, Nigel; Brugman, Curt; Butler, Christopher C

    2017-08-01

    Urine culture at the point of care minimises delay between obtaining the sample and agar inoculation in a microbiology laboratory, and quantification and sensitivity results can be available more rapidly in primary care. To identify the degree to which clinicians' interpretations of a point-of-care-test (POCT) urine culture (Flexicult™ SSI-Urinary Kit) agrees with laboratory culture in women presenting to primary care with symptoms of uncomplicated urinary tract infections (UTI). Primary care clinicians used the Flexicult™-POCT, recorded their findings and took a photograph of the result, which was interpreted by microbiology laboratory technicians. Urine samples were additionally processed in routine care laboratories. Cross tabulations were used to identify important differences in organism identification, quantification and antibiotic susceptibility between these three sources of data. The influence of various laboratory definitions for UTI on culture were assessed. Primary care clinicians identified 202/289 urine samples (69.9%) as positive for UTI using the Flexicult™-POCT, whereas laboratory culture identified 94-190 (32.5-65.7%) as positive, depending on definition thresholds. 82.9% of samples identified positive for E. coli on laboratory culture were also considered positive for E. coli using the Flexicult™ -POCT, and susceptibilities were reasonably concordant. There were major discrepancies between laboratory staff interpretation of Flexicult™ photographs, clinicians' interpretation of the Flexicult™ test, and laboratory culture results. Flexicult™-POCT overestimated the positivity rate of urine samples for UTI when laboratory culture was used as the reference standard. However, it is unclear whether point-of-care or laboratory based urine culture provides the most valid diagnostic information. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Pathogens and antimicrobial susceptibility profiles in critically ill patients with bloodstream infections: a descriptive study.

    PubMed

    Savage, Rachel D; Fowler, Robert A; Rishu, Asgar H; Bagshaw, Sean M; Cook, Deborah; Dodek, Peter; Hall, Richard; Kumar, Anand; Lamontagne, François; Lauzier, François; Marshall, John; Martin, Claudio M; McIntyre, Lauralyn; Muscedere, John; Reynolds, Steven; Stelfox, Henry T; Daneman, Nick

    2016-01-01

    Surveillance of antimicrobial resistance is vital to guiding empirical treatment of infections. Collating and reporting routine data on clinical isolate testing may offer more timely information about resistance patterns than traditional surveillance network methods. Using routine microbiology testing data collected from the Bacteremia Antibiotic Length Actually Needed for Clinical Effectiveness retrospective cohort study, we conducted a descriptive secondary analysis among critically ill patients in whom bloodstream infections had been diagnosed in 14 intensive care units (ICUs) in Canada. The participating sites were located within tertiary care teaching hospitals and represented 6 provinces and 10 cities. More than 80% of the study population was accrued from 2011-2013. We assessed the epidemiologic features of the infections and corresponding antimicrobial susceptibility profiles. Susceptibility testing was done according to Clinical Laboratory Standards Institute guidelines at accredited laboratories. A total of 1416 pathogens were isolated from 1202 patients. The most common organisms were Escherichia coli (217 isolates [15.3%]), Staphylococcus aureus (175 [12.4%]), coagulase-negative staphylococci (117 [8.3%]), Klebsiella pneumoniae (86 [6.1%]) and Streptococcus pneumoniae (85 [6.0%]). The contribution of individual pathogens varied by site. For 13 ICUs, gram-negative susceptibility rates were high for carbapenems (95.4%), tobramycin (91.2%) and piperacillin - tazobactam (90.0%); however, the proportion of specimens susceptible to these agents ranged from 75.0%-100%, 66.7%-100% and 75.0%-100%, respectively, across sites. Fewer gram-negative bacteria were susceptible to fluoroquinolones (84.5% [range 64.1%-97.2%]). A total of 145 patients (12.1%) had infections caused by highly resistant microorganisms, with significant intersite variation (range 2.6%-24.0%, χ2 = 57.50, p < 0.001). We assessed the epidemiologic features of bloodstream infections in a geographically diverse cohort of critically ill Canadian patients using routine pathogen and susceptibility data extracted from readily available microbiology testing databases. Expanding data sharing across more ICUs, with serial measurement and prompt reporting, could provide much-needed guidance for empiric treatment for patients as well as system-wide prevention methods to limit antimicrobial resistance.

  19. Pathogens and antimicrobial susceptibility profiles in critically ill patients with bloodstream infections: a descriptive study

    PubMed Central

    Savage, Rachel D.; Fowler, Robert A.; Rishu, Asgar H.; Bagshaw, Sean M.; Cook, Deborah; Dodek, Peter; Hall, Richard; Kumar, Anand; Lamontagne, François; Lauzier, François; Marshall, John; Martin, Claudio M.; McIntyre, Lauralyn; Muscedere, John; Reynolds, Steven; Stelfox, Henry T.; Daneman, Nick

    2016-01-01

    Background: Surveillance of antimicrobial resistance is vital to guiding empirical treatment of infections. Collating and reporting routine data on clinical isolate testing may offer more timely information about resistance patterns than traditional surveillance network methods. Methods: Using routine microbiology testing data collected from the Bacteremia Antibiotic Length Actually Needed for Clinical Effectiveness retrospective cohort study, we conducted a descriptive secondary analysis among critically ill patients in whom bloodstream infections had been diagnosed in 14 intensive care units (ICUs) in Canada. The participating sites were located within tertiary care teaching hospitals and represented 6 provinces and 10 cities. More than 80% of the study population was accrued from 2011-2013. We assessed the epidemiologic features of the infections and corresponding antimicrobial susceptibility profiles. Susceptibility testing was done according to Clinical Laboratory Standards Institute guidelines at accredited laboratories. Results: A total of 1416 pathogens were isolated from 1202 patients. The most common organisms were Escherichia coli (217 isolates [15.3%]), Staphylococcus aureus (175 [12.4%]), coagulase-negative staphylococci (117 [8.3%]), Klebsiella pneumoniae (86 [6.1%]) and Streptococcus pneumoniae (85 [6.0%]). The contribution of individual pathogens varied by site. For 13 ICUs, gram-negative susceptibility rates were high for carbapenems (95.4%), tobramycin (91.2%) and piperacillin-tazobactam (90.0%); however, the proportion of specimens susceptible to these agents ranged from 75.0%-100%, 66.7%-100% and 75.0%-100%, respectively, across sites. Fewer gram-negative bacteria were susceptible to fluoroquinolones (84.5% [range 64.1%-97.2%]). A total of 145 patients (12.1%) had infections caused by highly resistant microorganisms, with significant intersite variation (range 2.6%-24.0%, χ2 = 57.50, p < 0.001). Interpretation: We assessed the epidemiologic features of bloodstream infections in a geographically diverse cohort of critically ill Canadian patients using routine pathogen and susceptibility data extracted from readily available microbiology testing databases. Expanding data sharing across more ICUs, with serial measurement and prompt reporting, could provide much-needed guidance for empiric treatment for patients as well as system-wide prevention methods to limit antimicrobial resistance. PMID:28018869

  20. Laboratory heterogeneity of the lupus anticoagulant: a multicentre study using different clotting assays on a panel of 78 samples. Hemostasis Committee of the "Société Française de Biologie Clinique".

    PubMed

    1992-05-15

    The laboratory heterogeneity of the lupus anticoagulant (LA) was investigated in a multicentre study using a panel of 78 plasma samples diagnosed as containing a LA. Consecutive samples were collected by 12 participants using various screening tests, and sent to 7 laboratories which performed one or more clotting assays among the following: activated partial thromboplastin time (APTT), dilute Russell viper venom time, kaolin clotting time (KCT), dilute tissue thromboplastin time (dTTI) and a platelet neutralization test. For APTT and dTTI, 10 versions of these tests including standard and mixing procedures were carried out. They varied by reagents, phospholipid concentration or methodology. Cut-off times were determined for each test by comparing the results of the panel to those of a control population. When the data of all clotting assays were pooled, 70 of the 78 selected plasmas were considered to contain LA, 15 of them having a low-titer inhibitor. Sensitivity, defined as the proportion of positive results among LA-containing plasmas, varied from 62 to 100% and was positively related to responsiveness (defined as the mean ratio of clotting time to cut-off time). Laboratory heterogeneity of LA-containing plasma was illustrated by a star symbol plot analysis. Different populations of samples, with LA preferentially recognized by one assay (or group of assays) irrespective of the overall sensitivity of this assay, were identified. Multiple component analysis demonstrated the heterogeneity of low-titer inhibitors, which complicates their recognition in routine laboratory investigation.

  1. Triage and protocol recommendations for the parasitology laboratory based on an epidemiological investigation of parasite diagnostics in Ontario laboratories

    PubMed Central

    Maier, Allison; Krolik, Julia; Majury, Anna

    2014-01-01

    OBJECTIVES: A study was performed using a subset of Ontario laboratory parasitology data, with three objectives: to describe parasitic infections in Ontario; to identify risk factors for acquiring a parasitic infection using routinely collected information; and to use this information to assess current protocols for parasite testing in laboratories and, in turn, to propose alternatives to optimize the allocation of laboratory resources. METHODS: All parasitology records from January 4, 2010 to September 14, 2010 were reviewed descriptively and risk factor analyses were performed using information collected from requisitions. These results were used to develop preliminary alternative protocols, which considered high-throughput screening tests and inclusion/exclusion criteria for ova and parasite testing; these were then retrospectively analyzed with the dataset to determine appropriateness. RESULTS: Of the 29,260 records analyzed, 10% were multiple samples from single patients submitted on the same day, of which 98% had the same result. Three percent of all parasite tests were positive, with the most prevalent parasites being (in ascending order) Dientamoeba fragilis, Giardia lamblia, Cryptosporidium species and Entamoeba histolytica/dispar. Age and sex were found to be weak risk factors, while rural living was found to be a moderate risk factor for D fragilis, G lamblia and Cryptosporidium infections. The strongest risk factor was travel history, especially for nonendemic parasites. The retrospective analysis of six alternative protocols identified four that may be more efficient than current procedures. CONCLUSIONS: The present study demonstrated that current protocols may be redundant and can be optimized to target prevalent parasites and populations with high risk factors. PMID:25587292

  2. Automodification of PARP and fatty acid-based membrane lipidome as a promising integrated biomarker panel in molecular medicine.

    PubMed

    Bianchi, Anna Rita; Ferreri, Carla; Ruggiero, Simona; Deplano, Simone; Sunda, Valentina; Galloro, Giuseppe; Formisano, Cesare; Mennella, Maria Rosaria Faraone

    2016-01-01

    Establishing by statistical analyses whether the analyses of auto-modified poly(ADP-ribose)polymerase and erythrocyte membrane fatty acid composition (Fat Profile(®)), separately or in tandem, help monitoring the physio-pathology of the cell, and correlate with diseases, if present. Ninety five subjects were interviewed and analyzed blindly. Blood lymphocytes and erythrocytes were prepared to assay poly(ADP-ribose)polymerase automodification and fatty acid based membrane lipidome, respectively. Poly(ADP-ribose)polymerase automodification levels confirmed their correlation with DNA damage extent, and allowed monitoring disease activity, upon surgical/therapeutic treatment. Membrane lipidome profiles showed lipid unbalance mainly linked to inflammatory states. Statistically both tests were separately significant, and correlated each other within some pathologies. In the laboratory routine, both tests, separately or in tandem, might be a preliminary and helpful step to investigate the occurrence of a given disease. Their combination represents a promising integrated panel for sensible, noninvasive and routine health monitoring.

  3. Routine operation of an Elliott 903 computer in a clinical chemistry laboratory

    PubMed Central

    Whitby, L. G.; Simpson, D.

    1973-01-01

    Experience gained in the last four years concerning the capabilities and limitations of an 8K Elliott 903 (18-bit word) computer with magnetic tape backing store in the routine operation of a clinical chemistry laboratory is described. Designed as a total system, routine operation has latterly had to be confined to data acquisition and process control functions, due primarily to limitations imposed by the choice of hardware early in the project. In this final report of a partially successful experiment the opportunity is taken to review mistakes made, especially at the start of the project, to warn potential computer users of pitfalls to be avoided. PMID:4580240

  4. The burden of the variability introduced by the HEp-2 assay kit and the CAD system in ANA indirect immunofluorescence test.

    PubMed

    Infantino, M; Meacci, F; Grossi, V; Manfredi, M; Benucci, M; Merone, M; Soda, P

    2017-02-01

    According to the recent recommendations of the American College of Rheumatology, ANA Task Force, IIF technique should be considered the gold standard in antinuclear antibodies (ANAs) testing. To overcome the lack of standardization, biomedical industries have developed several computer-aided diagnosis (CAD) systems. Two hundred and sixty-one consecutive samples with suspected autoimmune diseases were tested for ANA by means of IIF on routinely HEp-2 assay kit (Euroimmun AG). Assignment of result was made if consensus for positive/negative was reached by at least 2 out of 3 expert physicians. ANA-IIF was also carried out using 3 CAD systems: Zenit G-Sight (n = 84), Helios (n = 85) and NOVA View (n = 92); human evaluation was repeated on the same substrate of each CAD system (Immco, Aesku and Inova HEp-2 cells, respectively). To anonymize the results, we randomly named these three systems as A, B and C. We ran a statistical analysis computing several measures of agreement between the ratings, and we also improved the evaluation by using the Wilcoxon's test for nonparametric data. Agreement between the human readings on routinely HEp-2 assay kit and human readings on CAD HEp-2 assay was substantial for A (k = 0.82) and B (k = 0.72), and almost perfect for C (k = 0.89). Such readings were statistically different only in case A. Comparing experts' readings with the readings of CAD systems, when the samples were prepared using CAD HEp-2 assay kits, we found almost perfect agreement for B and C (k = 0.86; k = 0.82) and substantial agreement for A (k = 0.73). Again, human and CAD readings were statistically different only in A. When we compared the readings of medical experts on routinely HEp-2 assay kit with the output of the CAD systems that worked using their own slides, we found substantial agreement for all the systems (A: k = 0.62; B: k = 0.65; C: k = 0.71). Such readings were not statistically different. The change of the assay kit and/or the introduction of a CAD system affect the laboratory reporting, with an evident impact on the autoimmune laboratory workflow. The CAD systems may represent one of the most important novel elements of harmonization in the autoimmunity field, reducing intra- and inter-laboratory variability in a new vision of the diagnostic autoimmune platform.

  5. Multicentre evaluation of a direct agglutination test prototype kit (DAT-LPC) for diagnosis of visceral leishmaniasis.

    PubMed

    Oliveira, E; Oliveira, D; Cardoso, F A; Barbosa, J R; Marcelino, A P; Dutra, T; Araujo, T; Fernandes, L; Duque, D; Rabello, A

    2017-12-01

    In this study, we assessed the sensitivity, specificity, and diagnostic accuracy of a previously developed direct agglutination test (DAT) using a freeze-dried antigen derived from Leishmania infantum promastigotes and composed in a prototype kit for visceral leishmaniasis (VL) diagnosis, named DAT-LPC. To evaluate DAT-LPC reproducibility, the kit was used to analyse 207 serum samples from VL patients and 80 serum samples from patients with other parasitic infections or healthy subjects in four laboratories from different public health institutions in Brazil. DAT-LPC showed sensitivity between 96·2 and 99·5% (P = 0·14), specificity ranging from 96·2 to 97·5% (P = 0·95), and diagnostic accuracy ranging from 96·5 to 99% (P = 0·34). The inter-laboratory reproducibility of qualitative results was classified as excellent (κ index: 0·94-0·97). The reproducibility of the end-titre results in relation to the reference laboratory, ranged from 31 to 85%. These results demonstrate an excellent performance of the DAT-LPC, and validate it for the diagnosis of VL that could replace the immunofluorescent antibody test as the routine diagnostic test in the Brazilian public health system.

  6. Loop-Mediated Isothermal Amplification for Laboratory Confirmation of Buruli Ulcer Disease—Towards a Point-of-Care Test

    PubMed Central

    Beissner, Marcus; Phillips, Richard Odame; Battke, Florian; Bauer, Malkin; Badziklou, Kossi; Sarfo, Fred Stephen; Maman, Issaka; Rhomberg, Agata; Piten, Ebekalisai; Frimpong, Michael; Huber, Kristina Lydia; Symank, Dominik; Jansson, Moritz; Wiedemann, Franz Xaver; Banla Kere, Abiba; Herbinger, Karl-Heinz; Löscher, Thomas; Bretzel, Gisela

    2015-01-01

    Background As the major burden of Buruli ulcer disease (BUD) occurs in remote rural areas, development of point-of-care (POC) tests is considered a research priority to bring diagnostic services closer to the patients. Loop-mediated isothermal amplification (LAMP), a simple, robust and cost-effective technology, has been selected as a promising POC test candidate. Three BUD-specific LAMP assays are available to date, but various technical challenges still hamper decentralized application. To overcome the requirement of cold-chains for transport and storage of reagents, the aim of this study was to establish a dry-reagent-based LAMP assay (DRB-LAMP) employing lyophilized reagents. Methodology/Principal Findings Following the design of an IS2404 based conventional LAMP (cLAMP) assay suitable to apply lyophilized reagents, a lyophylization protocol for the DRB-LAMP format was developed. Clinical performance of cLAMP was validated through testing of 140 clinical samples from 91 suspected BUD cases by routine assays, i.e. IS2404 dry-reagent-based (DRB) PCR, conventional IS2404 PCR (cPCR), IS2404 qPCR, compared to cLAMP. Whereas qPCR rendered an additional 10% of confirmed cases and samples respectively, case confirmation and positivity rates of DRB-PCR or cPCR (64.84% and 56.43%; 100% concordant results in both assays) and cLAMP (62.64% and 52.86%) were comparable and there was no significant difference between the sensitivity of the assays (DRB PCR and cPCR, 86.76%; cLAMP, 83.82%). Likewise, sensitivity of cLAMP (95.83%) and DRB-LAMP (91.67%) were comparable as determined on a set of 24 samples tested positive in all routine assays. Conclusions/Significance Both LAMP formats constitute equivalent alternatives to conventional PCR techniques. Provided the envisaged availability of field friendly DNA extraction formats, both assays are suitable for decentralized laboratory confirmation of BUD, whereby DRB-LAMP scores with the additional advantage of not requiring cold-chains. As validation of the assays was conducted in a third-level laboratory environment, field based evaluation trials are necessary to determine the clinical performance at peripheral health care level. PMID:26566026

  7. Coccidioidomycosis as a Common Cause of Community-acquired Pneumonia

    PubMed Central

    Valdivia, Lisa; Nix, David; Wright, Mark; Lindberg, Elizabeth; Fagan, Timothy; Lieberman, Donald; Stoffer, T'Prien; Ampel, Neil M.

    2006-01-01

    The early manifestations of coccidioidomycosis (valley fever) are similar to those of other causes of community-acquired pneumonia (CAP). Without specific etiologic testing, the true frequency of valley fever may be underestimated by public health statistics. Therefore, we conducted a prospective observational study of adults with recent onset of a lower respiratory tract syndrome. Valley fever was serologically confirmed in 16 (29%) of 55 persons (95% confidence interval 16%–44%). Antimicrobial medications were used in 81% of persons with valley fever. Symptomatic differences at the time of enrollment had insufficient predictive value for valley fever to guide clinicians without specific laboratory tests. Thus, valley fever is a common cause of CAP after exposure in a disease-endemic region. If CAP develops in persons who travel or reside in Coccidioides-endemic regions, diagnostic evaluation should routinely include laboratory evaluation for this organism. PMID:16707052

  8. A vascular laboratory protocol for improving and managing after-hours suspected acute deep venous thrombosis.

    PubMed

    Martin, Angela H; Eckert, George; Lemmon, Gary W; Sawchuk, Alan; Dalsing, Michael C

    2014-04-01

    This study reviews the clinical and workforce impact of a suggested protocol designed for the management of suspected acute deep venous thrombosis (DVT) in patients seen after standard vascular laboratory business hours. The protocol included the use of Wells score, D-dimer and a single dose of therapeutic anticoagulant to defer venous duplex ultrasound (VDU) testing until routine business hours unless contraindicated. Information was collected on medical history, physical exam and the timing of any diagnostic studies and treatment provided. Over 15% of studies done after-hours were deemed unnecessary by our protocol and in every individual the results were negative for an acute DVT. There were no adverse events from a one-time dose of anticoagulant. Limiting emergency VDU coverage to evaluate for acute DVT based on a management protocol can eliminate unnecessary after-hours VDU testing without having a negative impact on patient care.

  9. Constraints on transportation of reagents, reference materials and samples, difficulties and possible solutions: a user's perspective.

    PubMed

    Blanchard, P C

    2006-01-01

    The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.

  10. LABORATORY MISCONDUCT - WHAT CAN HAPPEN TO YOU?

    EPA Science Inventory

    Contracted laboratories perform a vast number of routine and special analytical services that are the foundation of decisions upon which rests the fate of the environment. Guiding these laboratories in the generation of environmental data has been the analytical protocols and ...

  11. Development of rearing and testing protocols for a new freshwater sediment test species: the gastropod Valvata piscinalis.

    PubMed

    Ducrot, Virginie; Cognat, Claudine; Mons, Raphaël; Mouthon, Jacques; Garric, Jeanne

    2006-03-01

    This paper aimed at proposing rearing and testing protocols for Valvata piscinalis, a new potential species for sediment toxicity testing. Such tests were developed since this species reliably represents the bio/ecological characteristics of other gastropods. It may thus be representative of their sensitivity to chemicals. V. piscinalis was successfully cultured in our laboratory for six generations. Cultures provided a high productivity for a low working time and low costs. The tests conditions we proposed seemed to be relevant for the development of reliable tests with this species. Indeed, hatching probability of egg-capsules, as well as embryo, newborn and juvenile survival rates, were close to 100%. Moreover, growth rates and fecundity were significantly higher than in field and in other laboratory studies. Partial life-cycle tests on clean sediments were achieved for various feeding levels to determine survival, growth and reproduction patterns, ad libitum feeding level and life cycle parameters values. Ad libitum feeding levels for newborn, juveniles and adults were 0.1, 0.4 and 0.8 mg Tetramin/individual/working day. Growth tests with zinc-spiked sediments provided a no-effect concentration and a lowest effect concentration of respectively 200 and 624 mg zinc/kg dry sediment. Other growth tests on spiked sediments we ran at our laboratory with second, third and fourth instars larvae of Chironomus riparius pointed out that V. piscinalis was more sensible to zinc than the chironomid, which is a routine test species in ecotoxicology. According to these results, V. piscinalis is a promising candidate species for sediment toxicity testing.

  12. External quality assessment of national public health laboratories in Africa, 2002–2009

    PubMed Central

    Perovic, Olga; Fensham, Vivian; McCarthy, Kerrigan; von Gottberg, Anne; de Gouveia, Linda; Poonsamy, Bhavani; Dini, Leigh; Rossouw, Jenny; Keddy, Karen; Alemu, Wondimagegnehu; Yahaya, Ali; Pierson, Antoine; Dolmazon, Virginie; Cognat, Sébastien; Ndihokubwayo, Jean Bosco

    2012-01-01

    Abstract Objective To describe findings from an external quality assessment programme involving laboratories in Africa that routinely investigate epidemic-prone diseases. Methods Beginning in 2002, the Regional Office for Africa of the World Health Organization (WHO) invited national public health laboratories and related facilities in Africa to participate in the programme. Three surveys comprising specimens and questionnaires associated with bacterial enteric diseases, bacterial meningitis, plague, tuberculosis and malaria were sent annually to test participants’ diagnostic proficiency. Identical surveys were sent to referee laboratories for quality control. Materials were prepared, packaged and shipped in accordance with standard protocols. Findings and reports were due within 30 days. Key methodological decisions and test results were categorized as acceptable or unacceptable on the basis of consensus feedback from referees, using established grading schemes. Findings Between 2002 and 2009, participation increased from 30 to 48 Member States of the WHO and from 39 to 78 laboratories. Each survey was returned by 64–93% of participants. Mean turnaround time was 25.9 days. For bacterial enteric diseases and meningitis components, bacterial identification was acceptable in 65% and 69% of challenges, respectively, but serotyping and antibiotic susceptibility testing and reporting were frequently unacceptable. Microscopy was acceptable for 73% of plague challenges. Tuberculosis microscopy was satisfactorily performed, with 87% of responses receiving acceptable scores. In the malaria component, 82% of responses received acceptable scores for species identification but only 51% of parasite quantitation scores were acceptable. Conclusion The external quality assessment programme consistently identified certain functional deficiencies requiring strengthening that were present in African public health microbiology laboratories. PMID:22461714

  13. Root cause analysis of laboratory turnaround times for patients in the emergency department.

    PubMed

    Fernandes, Christopher M B; Worster, Andrew; Hill, Stephen; McCallum, Catherine; Eva, Kevin

    2004-03-01

    Laboratory investigations are essential to patient care and are conducted routinely in emergency departments (EDs). This study reports the turnaround times at an academic, tertiary care ED, using root cause analysis to identify potential areas of improvement. Our objectives were to compare the laboratory turnaround times with established benchmarks and identify root causes for delays. Turnaround and process event times for a consecutive sample of hemoglobin and potassium measurements were recorded during an 8-day study period using synchronized time stamps. A log transformation (ln [minutes + 1]) was performed to normalize the time data, which were then compared with established benchmarks using one-sample t tests. The turnaround time for hemoglobin was significantly less than the established benchmark (n = 140, t = -5.69, p < 0.001) and that of potassium was significantly greater (n = 121, t = 12.65, p < 0.001). The hemolysis rate was 5.8%, with 0.017% of samples needing recollection. Causes of delays included order-processing time, a high proportion (43%) of tests performed on patients who had been admitted but were still in the ED waiting for a bed, and excessive laboratory process times for potassium. The turnaround time for hemoglobin (18 min) met the established benchmark, but that for potassium (49 min) did not. Root causes for delay were order-processing time, excessive queue and instrument times for potassium and volume of tests for admitted patients. Further study of these identified causes of delays is required to see whether laboratory TATs can be reduced.

  14. An outbreak of Legionnaires disease associated with a decorative water wall fountain in a hospital.

    PubMed

    Haupt, Thomas E; Heffernan, Richard T; Kazmierczak, James J; Nehls-Lowe, Henry; Rheineck, Bruce; Powell, Christine; Leonhardt, Kathryn K; Chitnis, Amit S; Davis, Jeffrey P

    2012-02-01

    To detect an outbreak-related source of Legionella, control the outbreak, and prevent additional Legionella infections from occurring. Epidemiologic investigation of an acute outbreak of hospital-associated Legionnaires disease among outpatients and visitors to a Wisconsin hospital. Patients with laboratory-confirmed Legionnaires disease who resided in southeastern Wisconsin and had illness onsets during February and March 2010. Patients with Legionnaires disease were interviewed using a hypothesis-generating questionnaire. On-site investigation included sampling of water and other potential environmental sources for Legionella testing. Case-finding measures included extensive notification of individuals potentially exposed at the hospital and alerts to area healthcare and laboratory personnel. Laboratory-confirmed Legionnaires disease was diagnosed in 8 patients, all of whom were present at the same hospital during the 10 days prior to their illness onsets. Six patients had known exposure to a water wall-type decorative fountain near the main hospital entrance. Although the decorative fountain underwent routine cleaning and maintenance, high counts of Legionella pneumophila serogroup 1 were isolated from cultures of a foam material found above the fountain trough. This outbreak of Legionnaires disease was associated with exposure to a decorative fountain located in a hospital public area. Routine cleaning and maintenance of fountains does not eliminate the risk of bacterial contamination. Our findings highlight the need to evaluate the safety of water fountains installed in any area of a healthcare facility.

  15. Analysis of Urinary Biomarkers for Smoking Crack Cocaine: Results of a Danish Laboratory Study.

    PubMed

    Jeppesen, Hans Henrik; Busch-Nielsen, Malthe; Larsen, Anders Nørgaard; Breindahl, Torben

    2015-01-01

    Crack cocaine (free-base cocaine) smokers belong to a subgroup of marginalized drug users exposed to severe health risks and great social harm. Detection of the urinary, pyrolytic biomarker methylecgonidine (MED) and its metabolite ecgonidine (ED) secures an unambiguous confirmation of crack cocaine smoking. Although prevalence studies of cocaine based upon self-reporting may not be accurate, laboratory analysis is seldom used for neither diagnostic purpose nor early identification of crack cocaine smoking, which is far more severe than snorting cocaine. A new analytical method was validated for MED, ED and other relevant cocaine metabolites using automated liquid handling and column switching coupled to liquid chromatography and tandem mass spectrometry. Limit of quantification was 30 ng/mL for ED and MED. This method was applied in a laboratory study of urine samples (n = 110) from cocaine users in Denmark subjected to routine drugs-of-abuse testing. Crack cocaine smoking was confirmed by the presence of MED and/or ED. Eighty-four samples (76.4%) were found positive for crack cocaine smoking in this group of problematic cocaine users. MED was only detected in 5.9% of the positive samples. The study shows a prevalence 3-fold higher to that recently suggested by European Monitoring Centre for Drugs and Drug Addiction. We therefore advocate that the urinary biomarkers MED and ED are included in routine testing methods for clinical toxicology. This may lead to an earlier identification of crack cocaine smoking and possibly prevent a more severe drug use. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. The relationship between liver histology and noninvasive markers in primary biliary cirrhosis.

    PubMed

    Olmez, Sehmus; Sayar, Suleyman; Avcioglu, Ufuk; Tenlik, İlyas; Ozaslan, Ersan; Koseoglu, Hasan T; Altiparmak, Emin

    2016-07-01

    Primary biliary cirrhosis (PBC) is a disease that affects liver with various severity and progression rates. It is important to diagnose advanced stage of the disease to lower liver-related morbidity and mortality. Since liver biopsy is an invasive method, liver biopsy tends to be replaced by noninvasive methods. In this study, we aim to show the role of aminotransferase to platelet ratio index (APRI) and fibrosis index on the basis of the four factors (FIB-4) scores, laboratory values, and their effectiveness in predicting advanced disease. PBC patients diagnosed pathologically at Numune Education and Research Hospital were included in the study between the years 1995 and 2013. Patients were grouped according to their fibrosis level: group 1 (early stage) included 18 patients with F1 and F2 fibrosis and group 2 (advanced stage) included 22 patients with F3 and F4 fibrosis. APRI and FIB-4 scores, routine laboratory values, and their proportions were compared. The effectiveness of parameters showing advanced stage was further compared. There were statistically significant differences in APRI, FIB-4 scores, and aspartate aminotransferase (AST) levels between the groups with early and advanced stages of disease. Receiver operating curve analysis was used to determine APRI, FIB-4 and AST levels. The most effective parameters for diagnosing an advanced stage were APRI, AST levels, and FIB-4 scores, respectively. In conclusion, APRI and FIB-4 scores can be calculated simply and easily by routine laboratory tests at low cost and also these scores may be a predictor of advanced stage of the disease in PBC. These tests may be reproducible and may be used to monitor disease progression.

  17. Mould routine identification in the clinical laboratory by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    PubMed

    Cassagne, Carole; Ranque, Stéphane; Normand, Anne-Cécile; Fourquet, Patrick; Thiebault, Sandrine; Planard, Chantal; Hendrickx, Marijke; Piarroux, Renaud

    2011-01-01

    MALDI-TOF MS recently emerged as a valuable identification tool for bacteria and yeasts and revolutionized the daily clinical laboratory routine. But it has not been established for routine mould identification. This study aimed to validate a standardized procedure for MALDI-TOF MS-based mould identification in clinical laboratory. First, pre-extraction and extraction procedures were optimized. With this standardized procedure, a 143 mould strains reference spectra library was built. Then, the mould isolates cultured from sequential clinical samples were prospectively subjected to this MALDI-TOF MS based-identification assay. MALDI-TOF MS-based identification was considered correct if it was concordant with the phenotypic identification; otherwise, the gold standard was DNA sequence comparison-based identification. The optimized procedure comprised a culture on sabouraud-gentamicin-chloramphenicol agar followed by a chemical extraction of the fungal colonies with formic acid and acetonitril. The identification was done using a reference database built with references from at least four culture replicates. For five months, 197 clinical isolates were analyzed; 20 were excluded because they were not identified at the species level. MALDI-TOF MS-based approach correctly identified 87% (154/177) of the isolates analyzed in a routine clinical laboratory activity. It failed in 12% (21/177), whose species were not represented in the reference library. MALDI-TOF MS-based identification was correct in 154 out of the remaining 156 isolates. One Beauveria bassiana was not identified and one Rhizopus oryzae was misidentified as Mucor circinelloides. This work's seminal finding is that a standardized procedure can also be used for MALDI-TOF MS-based identification of a wide array of clinically relevant mould species. It thus makes it possible to identify moulds in the routine clinical laboratory setting and opens new avenues for the development of an integrated MALDI-TOF MS-based solution for the identification of any clinically relevant microorganism.

  18. Variations in the detection of ZAP-70 in chronic lymphocytic leukemia: Comparison with IgV(H) mutation analysis.

    PubMed

    Sheikholeslami, M R; Jilani, I; Keating, M; Uyeji, J; Chen, K; Kantarjian, H; O'Brien, S; Giles, F; Albitar, M

    2006-07-15

    Lack of immunoglobulin heavy chain genes (IgV(H)) mutation in patients with chronic lymphocytic leukemia (CLL) is associated with rapid disease progression and shorter survival. The zeta-chain (T-cell receptor) associated protein kinase 70 kDa (ZAP-70) has been reported to be a surrogate marker for IgV(H) mutation status, and its expression in leukemic cells correlates with unmutated IgV(H). However, ZAP-70 detection by flow cytometry varies significantly dependant on the antibodies used, the method of performing the assay, and the condition of the cells in the specimen. The clinical value of ZAP-70 testing when samples are shipped under poorly controlled conditions is not known. Furthermore, testing in a research environment may differ from testing in a routine clinical laboratory. We validated an assay for ZAP-70 by comparing results with clinical outcome and the mutation status of the IgV(H). Using stored samples, we show significant correlation between ZAP-70 expression and clinical outcome as well as IgV(H) mutation at a cut-off point of 15%. While positive samples (>15% positivity) remain positive when kept in the laboratory environment for 48 h after initial testing, results obtained from samples from CLL patients tested after shipping at room temperature for routine testing showed no correlation with IgV(H) mutation status when 15% cut-off was used. In these samples, cut-point of 10% correlated with the IgV(H) mutation (P = 0.0001). This data suggests that although ZAP-70 positivity correlates with IgV(H) mutation status and survival, variations in sample handling and preparation may influence results. We show that IgV(H) mutation results, unlike ZAP-70 remain correlated with CD38 expression and beta-2 microglobulin in shipped samples, and ZAP-70 testing should not be used as the sole criterion for stratifying patients for therapy. (c) 2006 International Society for Analytical Cytology.

  19. Biochemical Phenotypes to Discriminate Microbial Subpopulations and Improve Outbreak Detection

    PubMed Central

    Galar, Alicia; Kulldorff, Martin; Rudnick, Wallis; O'Brien, Thomas F.; Stelling, John

    2013-01-01

    Background Clinical microbiology laboratories worldwide constitute an invaluable resource for monitoring emerging threats and the spread of antimicrobial resistance. We studied the growing number of biochemical tests routinely performed on clinical isolates to explore their value as epidemiological markers. Methodology/Principal Findings Microbiology laboratory results from January 2009 through December 2011 from a 793-bed hospital stored in WHONET were examined. Variables included patient location, collection date, organism, and 47 biochemical and 17 antimicrobial susceptibility test results reported by Vitek 2. To identify biochemical tests that were particularly valuable (stable with repeat testing, but good variability across the species) or problematic (inconsistent results with repeat testing), three types of variance analyses were performed on isolates of K. pneumonia: descriptive analysis of discordant biochemical results in same-day isolates, an average within-patient variance index, and generalized linear mixed model variance component analysis. Results: 4,200 isolates of K. pneumoniae were identified from 2,485 patients, 32% of whom had multiple isolates. The first two variance analyses highlighted SUCT, TyrA, GlyA, and GGT as “nuisance” biochemicals for which discordant within-patient test results impacted a high proportion of patient results, while dTAG had relatively good within-patient stability with good heterogeneity across the species. Variance component analyses confirmed the relative stability of dTAG, and identified additional biochemicals such as PHOS with a large between patient to within patient variance ratio. A reduced subset of biochemicals improved the robustness of strain definition for carbapenem-resistant K. pneumoniae. Surveillance analyses suggest that the reduced biochemical profile could improve the timeliness and specificity of outbreak detection algorithms. Conclusions The statistical approaches explored can improve the robust recognition of microbial subpopulations with routinely available biochemical test results, of value in the timely detection of outbreak clones and evolutionarily important genetic events. PMID:24391936

  20. Multicenter Clinical Evaluation of the Novel Alere i Strep A Isothermal Nucleic Acid Amplification Test.

    PubMed

    Cohen, Daniel M; Russo, Michael E; Jaggi, Preeti; Kline, Jennifer; Gluckman, William; Parekh, Amisha

    2015-07-01

    Rapid detection of group A beta-hemolytic streptococcus (GAS) is used routinely to help diagnose and treat pharyngitis. However, available rapid antigen detection tests for GAS have relatively low sensitivity, and backup testing is recommended in children. Newer assays are more sensitive yet require excessive time for practical point-of-care use as well as laboratory personnel. The Alere i strep A test is an isothermal nucleic acid amplification test designed to offer highly sensitive results at the point of care within 8 min when performed by nonlaboratory personnel. The performance of the Alere i strep A test was evaluated in a multicenter prospective trial in a Clinical Laboratory Improvement Amendments (CLIA)-waived setting in comparison to bacterial culture in 481 children and adults. Compared to culture, the Aleri i strep A test had 96.0% sensitivity and 94.6% specificity. Discrepant results were adjudicated by PCR and found the Alere i strep A test to have 98.7% sensitivity and 98.5% specificity. Overall, the Alere i strep A test could provide a one-step, rapid, point-of-care testing method for GAS pharyngitis and obviate backup testing on negative results. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  1. Missed diagnostic opportunities within South Africa's early infant diagnosis program, 2010-2015.

    PubMed

    Haeri Mazanderani, Ahmad; Moyo, Faith; Sherman, Gayle G

    2017-01-01

    Samples submitted for HIV PCR testing that fail to yield a positive or negative result represent missed diagnostic opportunities. We describe HIV PCR test rejections and indeterminate results, and the associated delay in diagnosis, within South Africa's early infant diagnosis (EID) program from 2010 to 2015. HIV PCR test data from January 2010 to December 2015 were extracted from the National Health Laboratory Service Corporate Data Warehouse, a central data repository of all registered test-sets within the public health sector in South Africa, by laboratory number, result, date, facility, and testing laboratory. Samples that failed to yield either a positive or negative result were categorized according to the rejection code on the laboratory information system, and descriptive analysis performed using Microsoft Excel. Delay in diagnosis was calculated for patients who had a missed diagnostic opportunity registered between January 2013 and December 2015 by means of a patient linking-algorithm employing demographic details. Between 2010 and 2015, 2 178 582 samples were registered for HIV PCR testing of which 6.2% (n = 134 339) failed to yield either a positive or negative result, decreasing proportionally from 7.0% (n = 20 556) in 2010 to 4.4% (n = 21 388) in 2015 (p<0.001). Amongst 76 972 coded missed diagnostic opportunities, 49 585 (64.4%) were a result of pre-analytical error and 27 387 (35.6%) analytical error. Amongst 49 694 patients searched for follow-up results, 16 895 (34.0%) had at least one subsequent HIV PCR test registered after a median of 29 days (IQR: 13-57), of which 8.4% tested positive compared with 3.6% of all samples submitted for the same period. Routine laboratory data provides the opportunity for near real-time surveillance and quality improvement within the EID program. Delay in diagnosis and wastage of resources associated with missed diagnostic opportunities must be addressed and infants actively followed-up as South Africa works towards elimination of mother-to-child transmission.

  2. [Clinical diagnosis of primary unknown cancer-the present situation and problems].

    PubMed

    Mukai, Hirofumi

    2009-06-01

    The first step of diagnosis of primary unknown cancer(PUC)the detailed history intake and physical examination including breast, genitourinary system and rectum. Laboratory test, chest X-p and systemic computed tomography are allowed to be performed for all patients with PUC. Other tests should be performed according to the results of clinical and pathological evaluation. Utility of the tumor marker is limited, and this test is not recommended as a routine usage. There is not enough evidence on the utility of FDG-PTT or FDG-PET/CT for patients with PUC. Diagnosis of PUC should be made within one month from a patient's first visit to a hospital.

  3. Betrixaban: Impact on Routine and Specific Coagulation Assays-A Practical Laboratory Guide.

    PubMed

    Siriez, Romain; Evrard, Jonathan; Dogné, Jean-Michel; Pochet, Lionel; Gheldof, Damien; Chatelain, Bernard; Mullier, François; Douxfils, Jonathan

    2018-06-11

     Betrixaban is a novel direct oral factor Xa inhibitor approved by the Food and Drug Administration for prophylaxis of venous thromboembolism in adult patients hospitalized for an acute illness at risk for thromboembolic complications. Assessment of the anti-coagulant effect of betrixaban may be useful in some situations. Also, clinicians need to know how routine coagulation assays are influenced.  The aim of this study is to determine which coagulation assay(s) should be used to assess the impact of betrixaban on haemostasis and provide laboratory guidance for their interpretation.  Betrixaban was spiked at final concentrations ranging from 0 to 250 ng/mL in platelet-poor plasma. Different reagents from several manufacturers were tested and the impact of betrixaban on pro-thrombin time (PT), activated partial thromboplastin time (aPTT), dilute Russel viper venom time (dRVV-T), chromogenic anti-Xa assays, thrombin generation assay (TGA), and a large panel of haemostasis diagnostic tests has been assessed.  A concentration-dependent prolongation of aPTT, PT and dRVV-T is observed. The sensitivity mainly depends on the reagent. Chromogenic anti-Xa assays show high sensitivity depending on the reagent and/or the methodology. These assays applicable for other direct factor Xa inhibitors have to be adapted to obtain a relevant range of measurement. TGA may also be attractive to assess the anti-coagulant activity of betrixaban.  Adapted chromogenic anti-Xa assays are the most appropriate assays to estimate the concentration of betrixaban. Betrixaban significantly affects several haemostasis diagnostic tests and this needs to be taken into consideration when requesting and interpreting such tests. Schattauer GmbH Stuttgart.

  4. A step towards standardization: A method for end-point titer determination by fluorescence index of an automated microscope. End-point titer determination by fluorescence index.

    PubMed

    Carbone, Teresa; Gilio, Michele; Padula, Maria Carmela; Tramontano, Giuseppina; D'Angelo, Salvatore; Pafundi, Vito

    2018-05-01

    Indirect Immunofluorescence (IIF) is widely considered the Gold Standard for Antinuclear Antibody (ANA) screening. However, the high inter-reader variability remains the major disadvantage associated with ANA testing and the main reason for the increasing demand of the computer-aided immunofluorescence microscope. Previous studies proposed the quantification of the fluorescence intensity as an alternative for the classical end-point titer evaluation. However, the different distribution of bright/dark light linked to the nature of the self-antigen and its location in the cells result in different mean fluorescence intensities. The aim of the present study was to correlate Fluorescence Index (F.I.) with end-point titers for each well-defined ANA pattern. Routine serum samples were screened for ANA testing on HEp-2000 cells using Immuno Concepts Image Navigator System, and positive samples were serially diluted to assign the end-point titer. A comparison between F.I. and end-point titers related to 10 different staining patterns was made. According to our analysis, good technical performance of F.I. (97% sensitivity and 94% specificity) was found. A significant correlation between quantitative reading of F.I. and end-point titer groups was observed using Spearman's test and regression analysis. A conversion scale of F.I. in end-point titers for each recognized ANA-pattern was obtained. The Image Navigator offers the opportunity to improve worldwide harmonization of ANA test results. In particular, digital F.I. allows quantifying ANA titers by using just one sample dilution. It could represent a valuable support for the routine laboratory and an effective tool to reduce inter- and intra-laboratory variability. Copyright © 2018. Published by Elsevier B.V.

  5. The determination of ethyl glucuronide in hair: Experiences from nine consecutive interlaboratory comparison rounds.

    PubMed

    Becker, R; Lô, I; Sporkert, F; Baumgartner, M

    2018-07-01

    The increasing request for hair ethyl glucuronide (HEtG) in alcohol consumption monitoring according to cut-off levels set by the Society of Hair Testing (SoHT) has triggered a proficiency testing program based on interlaboratory comparisons (ILC). Here, the outcome of nine consecutive ILC rounds organised by the SoHT on the determination of HEtG between 2011 and 2017 is summarised regarding interlaboratory reproducibility and the influence of procedural variants. Test samples prepared from cut hair (1mm) with authentic (in-vivo incorporated) and soaked (in-vitro incorporated) HEtG concentrations up to 80pg/mg were provided for 27-35 participating laboratories. Laboratory results were evaluated according to ISO 5725-5 and provided robust averages and relative reproducibility standard deviations typically between 20 and 35% in reasonable accordance with the prediction of the Horwitz model. Evaluation of results regarding the analytical techniques revealed no significant differences between gas and liquid chromatographic methods In contrast, a detailed evaluation of different sample preparations revealed significantly higher average values in case when pulverised hair is tested compared to cut hair. This observation was reinforced over the different ILC rounds and can be attributed to the increased acceptance and routine of hair pulverisation among laboratories. Further, the reproducibility standard deviations among laboratories performing pulverisation were on average in very good agreement with the prediction of the Horwitz model. Use of sonication showed no effect on the HEtG extraction yield. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Pareizs, J.; Coleman, C.

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt ormore » SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.« less

  7. Chromosomal microarray analysis as the first-tier test for the identification of pathogenic copy number variants in chromosome 9 pericentric regions and its challenge.

    PubMed

    Wang, Jia-Chi; Boyar, Fatih Z

    2016-01-01

    Chromosomal microarray analysis (CMA) has been recommended and practiced routinely in the large reference laboratories of U.S.A. as the first-tier test for the postnatal evaluation of individuals with intellectual disability, autism spectrum disorders, and/or multiple congenital anomalies. Using CMA as a diagnostic tool and without a routine setting of fluorescence in situ hybridization with labeled bacterial artificial chromosome probes (BAC-FISH) in the large reference laboratories becomes a challenge in the characterization of chromosome 9 pericentric region. This region has a very complex genomic structure and contains a variety of heterochromatic and euchromatic polymorphic variants. These variants were usually studied by G-banding, C-banding and BAC-FISH analysis. Chromosomal microarray analysis (CMA) was not recommended since it may lead to false positive results. Here, we presented a cohort of four cases, in which high-resolution CMA was used as the first-tier test or simultaneously with G-banding analysis on the proband to identify pathogenic copy number variants (CNVs) in the whole genome. CMA revealed large pathogenic CNVs from chromosome 9 in 3 cases which also revealed different G-banding patterns between the two chromosome 9 homologues. Although we demonstrated that high-resolution CMA played an important role in the identification of pathogenic copy number variants in chromosome 9 pericentric regions, the lack of BAC-FISH analysis or other useful tools renders significant challenges in the characterization of chromosome 9 pericentric regions. None; it is not a clinical trial, and the cases were retrospectively collected and analyzed.

  8. Autoclaving practice in microbiology laboratories: report of a survey. The Public Health Laboratory Service Subcommittee on laboratory autoclaves.

    PubMed Central

    1978-01-01

    The performance of autoclaves in 27 laboratories, operated in accordance with the normal routine of local practice, has been monitored using thermometric equipment. Sterilising performance was unsatisfactory on 10 of 62 occasions, and cooling was inadequate on 52 of 60 occasions. PMID:649767

  9. Simple, rapid, and cost-effective modified Carba NP test for carbapenemase detection among Gram-negative bacteria

    PubMed Central

    Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha

    2017-01-01

    PURPOSE: Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. MATERIALS AND METHODS: The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. RESULTS: A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. CONCLUSION: The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings. PMID:28966495

  10. Simple, rapid, and cost-effective modified Carba NP test for carbapenemase detection among Gram-negative bacteria.

    PubMed

    Rudresh, Shoorashetty Manohara; Ravi, Giriyapur Siddappa; Sunitha, Lakshminarayanappa; Hajira, Sadiya Noor; Kalaiarasan, Ellappan; Harish, Belgode Narasimha

    2017-01-01

    Detection of carbapenemases among Gram-negative bacteria (GNB) is important for both clinicians and infection control practitioners. The Clinical and Laboratory Standards Institute recommends Carba NP (CNP) as confirmatory test for carbapenemase production. The reagents required for CNP test are costly and hence the test cannot be performed on a routine basis. The present study evaluates modifications of CNP test for rapid detection of carbapenemases among GNB. The GNB were screened for carbapenemase production using CNP, CarbAcineto NP (CANP), and modified CNP (mCNP) test. A multiplex polymerase chain reaction (PCR) was performed on all the carbapenem-resistant bacteria for carbapenemase genes. The results of three phenotypic tests were compared with PCR. A total of 765 gram negative bacteria were screened for carbapenem resistance. Carbapenem resistance was found in 144 GNB. The metallo-β-lactamases were most common carbapenemases followed by OXA-48-like enzymes. The CANP test was most sensitive (80.6%) for carbapenemases detection. The mCNP test was 62.1% sensitive for detection of carbapenemases. The mCNP, CNP, and CANP tests were equally sensitive (95%) for detection of NDM enzymes among Enterobacteriaceae. The mCNP test had poor sensitivity for detection of OXA-48-like enzymes. The mCNP test was rapid, cost-effective, and easily adoptable on routine basis. The early detection of carbapenemases using mCNP test will help in preventing the spread of multidrug-resistant organisms in the hospital settings.

  11. GMOtrack: generator of cost-effective GMO testing strategies.

    PubMed

    Novak, Petra Krau; Gruden, Kristina; Morisset, Dany; Lavrac, Nada; Stebih, Dejan; Rotter, Ana; Zel, Jana

    2009-01-01

    Commercialization of numerous genetically modified organisms (GMOs) has already been approved worldwide, and several additional GMOs are in the approval process. Many countries have adopted legislation to deal with GMO-related issues such as food safety, environmental concerns, and consumers' right of choice, making GMO traceability a necessity. The growing extent of GMO testing makes it important to study optimal GMO detection and identification strategies. This paper formally defines the problem of routine laboratory-level GMO tracking as a cost optimization problem, thus proposing a shift from "the same strategy for all samples" to "sample-centered GMO testing strategies." An algorithm (GMOtrack) for finding optimal two-phase (screening-identification) testing strategies is proposed. The advantages of cost optimization with increasing GMO presence on the market are demonstrated, showing that optimization approaches to analytic GMO traceability can result in major cost reductions. The optimal testing strategies are laboratory-dependent, as the costs depend on prior probabilities of local GMO presence, which are exemplified on food and feed samples. The proposed GMOtrack approach, publicly available under the terms of the General Public License, can be extended to other domains where complex testing is involved, such as safety and quality assurance in the food supply chain.

  12. Review of the current state of whole slide imaging in pathology

    PubMed Central

    Pantanowitz, Liron; Valenstein, Paul N.; Evans, Andrew J.; Kaplan, Keith J.; Pfeifer, John D.; Wilbur, David C.; Collins, Laura C.; Colgan, Terence J.

    2011-01-01

    Whole slide imaging (WSI), or “virtual” microscopy, involves the scanning (digitization) of glass slides to produce “digital slides”. WSI has been advocated for diagnostic, educational and research purposes. When used for remote frozen section diagnosis, WSI requires a thorough implementation period coupled with trained support personnel. Adoption of WSI for rendering pathologic diagnoses on a routine basis has been shown to be successful in only a few “niche” applications. Wider adoption will most likely require full integration with the laboratory information system, continuous automated scanning, high-bandwidth connectivity, massive storage capacity, and more intuitive user interfaces. Nevertheless, WSI has been reported to enhance specific pathology practices, such as scanning slides received in consultation or of legal cases, of slides to be used for patient care conferences, for quality assurance purposes, to retain records of slides to be sent out or destroyed by ancillary testing, and for performing digital image analysis. In addition to technical issues, regulatory and validation requirements related to WSI have yet to be adequately addressed. Although limited validation studies have been published using WSI there are currently no standard guidelines for validating WSI for diagnostic use in the clinical laboratory. This review addresses the current status of WSI in pathology related to regulation and validation, the provision of remote and routine pathologic diagnoses, educational uses, implementation issues, and the cost-benefit analysis of adopting WSI in routine clinical practice. PMID:21886892

  13. Improved procedure for determination of flucytosine in human blood plasma by high-pressure liquid chromatography.

    PubMed Central

    Schwertschlag, U; Nakata, L M; Gal, J

    1984-01-01

    Several high-pressure liquid chromatography procedures for the determination of flucytosine in serum or plasma have appeared. Some of these suffer from significant disadvantages, and none was applicable in our routine clinical therapeutic-drug-monitoring laboratory. A new high-pressure liquid chromatography assay for flucytosine was therefore developed. A 100-microliter sample of plasma was treated with an aqueous 5-iodocytosine internal-standard solution, and the mixture was deproteinized with trichloroacetic acid. A portion of the protein-free supernatant was diluted with 0.1 M ammonium phosphate, and an aliquot of the resulting solution was injected into the high-pressure liquid chromatography system. Chromatography was performed on a strong-cation-exchange column with a mobile phase containing aqueous ammonium phosphate, phosphoric acid, methanol, and acetonitrile. Detection was at 254 nm. The assay was shown to be linear in the 10 to 200-micrograms/ml drug-concentration range. Forty other drugs were tested for potential interference with the assay, and none was found. For routine use, a single-point working standard containing 75 micrograms of flucytosine per ml was used, giving intraassay coefficients of variation at 50 and 150 micrograms/ml of 1.8 and 2.3% respectively, whereas the day-to-day coefficient of variation at 50 micrograms/ml was 10.0%. Advantages of the procedure include the small sample size, the use of a convenient and reliable internal standard, speed, and simplicity. The assay is highly suitable for routine clinical drug-analysis laboratories. PMID:6508261

  14. Extrapulmonary involvement in patients with sarcoidosis and comparison of routine laboratory and clinical data to pulmonary involvement.

    PubMed

    Zurkova, Monika; Kolek, Vitezslav; Tomankova, Tereza; Kriegova, Eva

    2014-12-01

    Patients with pulmonary and pulmonary plus extrapulmonary sarcoidosis differ in symptom severity and health status impairment. To date there is no information on differences in clinical and laboratory parameters between these phenotypes and limited information on extrapulmonary involvement in Czech sarcoidosis patients exists. We therefore compared clinical data (age, gender, organ involvement, lung function tests) and laboratory data (blood counts, bronchoalveolar fluid (BAL) cellular profile, serum levels of CRP, SACE, sIL-2R, neopterin) between patients with newly diagnosed pulmonary sarcoidosis (n=107) and those with pulmonary plus extrapulmonary sarcoidosis (n=54). Extrapulmonary sarcoidosis was diagnosed in 33% of patients, mostly affecting lymph nodes and skin and having hypercalciuria. There was no difference in the prevalence of extrapulmonary sarcoidosis between genders. Patients with extrapulmonary sarcoidosis were older and mostly non-smokers when compared to those with limited pulmonary form. X-ray Stage I and erythema nodosum were less frequent in extrapulmonary disease. Serum levels of CRP, SACE, sIL-2R and neopterin and BAL cellular profile did not differ between both phenotypes. We observed lower platelets, FEV1, VC, and BAL CD19+ in females with extrapulmonary involvement than in those with pulmonary disease. Affected lymph nodes, skin and hypercalciuria were the most common in sarcoidosis patients with extrapulmonary involvement. Pulmonary sarcoidosis did not differ in clinical and routine laboratory parameters from pulmonary plus extrapulmonary sarcoidosis. Observation of low platelets, VC, FEV1 and BAL CD19+ in females with extrapulmonary sarcoidosis needs further verification in larger cohort.

  15. Tinea Capitis: Current Status.

    PubMed

    Hay, R J

    2017-02-01

    Tinea capitis remains a common childhood infection in many parts of the world. Yet knowledge of the underlying pathogenetic mechanisms and the development of effective immunity have shown striking advances, and new methods of diagnosis ranging from dermoscopy to molecular laboratory tests have been developed even though they have not been assimilated into routine practice in many centres. Treatment is effective although it needs to be given for at least 1 month. What is missing, however, is a systematic approach to control through case ascertainment and therapy.

  16. Analytical Strategies to Disclose Repeated Consumption of New Psychoactive Substances by Hair Analysis.

    PubMed

    Rotolo, Maria C; Klein, Julia; Pacifici, Roberta; Busardo, Francesco Paolo; Pichini, Simona; Marchei, Emilia

    2017-01-01

    New psychoactive substances (NPS) are a heterogenic group of substances with different chemical structures and psychotropic effects. Many pharmacotoxicological laboratories performing drug testing in conventional and nonconventional biological matrices for clinical and forensic purposes do not include screening procedures for NPS in their routine protocols. This is mainly due to the continued entry in the market of newly synthesized products, the low availability of reference standards, in particular of their metabolites, the low availability of immunochemical kits, etc. Moreover, many of the new compounds are very potent, and low doses ingested will lead to low concentrations in biological matrices, especially in hair. Hair analysis has become a powerful tool for detecting chronic drug use and has become a routine technique in forensic toxicology laboratories. The aim of this study was to set up analytical strategies to identify repeated consumption of NPS by hair analysis. Although UHPLC-MS/MS may represent the elective technique in studying NPS, a combination of both GC-MS and UHPLC-MS/MS techniques is useful in creating a complete toxicological image. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  17. Methods in virus diagnostics: from ELISA to next generation sequencing.

    PubMed

    Boonham, Neil; Kreuze, Jan; Winter, Stephan; van der Vlugt, René; Bergervoet, Jan; Tomlinson, Jenny; Mumford, Rick

    2014-06-24

    Despite the seemingly continuous development of newer and ever more elaborate methods for detecting and identifying viruses, very few of these new methods get adopted for routine use in testing laboratories, often despite the many and varied claimed advantages they possess. To understand why the rate of uptake of new technologies is so low, requires a strong understanding of what makes a good routine diagnostic tool to begin. This can be done by looking at the two most successfully established plant virus detection methods: enzyme-linked immunosorbant assay (ELISA) and more recently introduced real-time polymerase chain reaction (PCR). By examining the characteristics of this pair of technologies, it becomes clear that they share many benefits, such as an industry standard format and high levels of repeatability and reproducibility. These combine to make methods that are accessible to testing labs, which are easy to establish and robust in their use, even with new and inexperienced users. Hence, to ensure the establishment of new techniques it is necessary to not only provide benefits not found with ELISA or real-time PCR, but also to provide a platform that is easy to establish and use. In plant virus diagnostics, recent developments can be clustered into three core areas: (1) techniques that can be performed in the field or resource poor locations (e.g., loop-mediated isothermal amplification LAMP); (2) multiplex methods that are able to detect many viruses in a single test (e.g., Luminex bead arrays); and (3) methods suited to virus discovery (e.g., next generation sequencing, NGS). Field based methods are not new, with Lateral Flow Devices (LFDs) for the detection being available for a number of years now. However, the widespread uptake of this technology remains poor. LAMP does offer significant advantages over LFDs, in terms of sensitivity and generic application, but still faces challenges in terms of establishment. It is likely that the main barrier to the uptake of field-based technologies is behavioural influences, rather than specific concerns about the performance of the technologies themselves. To overcome this, a new relationship will need to develop between centralised testing laboratories offering services and those requiring tests; a relationship which is currently in its infancy. Looking further into the future, virus discovery and multiplex methods seem to converge as NGS becomes ever cheaper, easier to perform and can provide high levels of multiplexing without the use of virus specific reagents. So ultimately the key challenge from a routine testing lab perspective will not be one of investment in platforms-which could even be outsourced to commercial sequencing services-but one of having the skills and expertise to analyse the large datasets generated and their subsequent interpretation. In conclusion, only time will tell which of the next-generation of methods currently in development will become the routine diagnostics of the future. This will be determined through a combination of factors. And while the technology itself will have to offer performance advantages over existing methods in order to supplant them, it is likely to be human factors e.g., the behaviours of end users, laboratories and policy makers, the availability of appropriate expertise, that ultimately determine which ones become established. Hence factors cannot be ignored and early engagement with diagnostic stakeholders is essential. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  18. Review of systems, physical examination, and routine tests for case-finding in ambulatory patients.

    PubMed

    Boland, B J; Wollan, P C; Silverstein, M D

    1995-04-01

    The screening value of the comprehensive review of systems and the complete physical examination in detecting unsuspected diseases for which therapeutic interventions are initiated has not been formally studied in ambulatory patients. The medical records of 100 randomly selected adult patients who had an ambulatory general medical evaluation at the Mayo Clinic in 1990-1991 were surveyed to compare review of systems and physical examination with routine laboratory tests, chest radiography, and electrocardiography as case-finding maneuvers. The main outcome measure was the therapeutic yield of each case-finding maneuver, defined as the proportion of maneuvers leading to a new therapy for a new clinically important diagnosis. The utilization rate of routine tests in the 100 patients (mean age: 59 +/- 16 years; 58% women) was high, ranging from 77 to 98%. Overall, the case-finding maneuvers led to 36 unsuspected clinically important diagnoses and resulted in 25 new therapeutic interventions. Higher therapeutic yield was observed for review of systems (7%), physical examination (5%), and lipid screening (9.2%) than for chemistry group (2.2%), complete blood count (1.8%), thyroid tests (1.5%), urinalysis (1.1%), electrocardiography (0%), or chest radiography (0%). The number of therapeutic interventions was not associated with patient's age (P = 0.55), sex (P = 0.88), comorbidity (P = 0.30) or with the time interval since the last general medical evaluation (P = 0.12). Based on therapeutic yield, these data suggest that review of systems and physical examination are valuable case-finding maneuvers in the periodic medical evaluation of ambulatory patients.

  19. The role of informal dimensions of safety in high-volume organisational routines: an ethnographic study of test results handling in UK general practice.

    PubMed

    Grant, Suzanne; Checkland, Katherine; Bowie, Paul; Guthrie, Bruce

    2017-04-27

    The handling of laboratory, imaging and other test results in UK general practice is a high-volume organisational routine that is both complex and high risk. Previous research in this area has focused on errors and harm, but a complementary approach is to better understand how safety is achieved in everyday practice. This paper ethnographically examines the role of informal dimensions of test results handling routines in the achievement of safety in UK general practice and how these findings can best be developed for wider application by policymakers and practitioners. Non-participant observation was conducted of high-volume organisational routines across eight UK general practices with diverse organisational characteristics. Sixty-two semi-structured interviews were also conducted with the key practice staff alongside the analysis of relevant documents. While formal results handling routines were described similarly across the eight study practices, the everyday structure of how the routine should be enacted in practice was informally understood. Results handling safety took a range of local forms depending on how different aspects of safety were prioritised, with practices varying in terms of how they balanced thoroughness (i.e. ensuring the high-quality management of results by the most appropriate clinician) and efficiency (i.e. timely management of results) depending on a range of factors (e.g. practice history, team composition). Each approach adopted created its own potential risks, with demands for thoroughness reducing productivity and demands for efficiency reducing handling quality. Irrespective of the practice-level approach adopted, staff also regularly varied what they did for individual patients depending on the specific context (e.g. type of result, patient circumstances). General practices variably prioritised a legitimate range of results handling safety processes and outcomes, each with differing strengths and trade-offs. Future safety improvement interventions should focus on how to maximise practice-level knowledge and understanding of the range of context-specific approaches available and the safeties and risks inherent in each within the context of wider complex system conditions and interactions. This in turn has the potential to inform new kinds of proactive, contextually appropriate approaches to intervention development and implementation focusing on the enhanced deliberation of the safety of existing high-volume routines.

  20. Screening for hypopituitarism in 509 patients with traumatic brain injury or subarachnoid hemorrhage.

    PubMed

    Kopczak, Anna; Kilimann, Ingo; von Rosen, Friedrich; Krewer, Carmen; Schneider, Harald Jörn; Stalla, Günter Karl; Schneider, Manfred

    2014-01-01

    We performed a screening on patients with traumatic brain injury (TBI) or subarachnoid hemorrhage (SAH) to determine the prevalence of post-traumatic hypopituitarism in neurorehabilitation in a cross-sectional, observational single-center study. In addition, the therapeutic consequences of our screening were analyzed retrospectively. From February 2006 to August 2009, patients between 18 and 65 years (n=509) with the diagnosis of TBI (n=340) or SAH (n=169) were screened within two weeks of admittance to neurorehabilitation as clinical routine. Blood was drawn to determine fasting cortisol, free thyroxine (fT4), prolactin, testosterone or estradiol, and insulin-like growth factor I (IGF-I). Patients with abnormalities in the screening or clinical signs of hypopituitarism received further stimulation tests: growth hormone releasing hormone -L-arginine-test and adrenocorticotrophic hormone (ACTH)-test (n=36); ACTH-test alone (n=26); or insulin tolerance test (n=56). In our screening of 509 patients, 28.5% showed lowered values in at least one hormone of the hypothalamus-pituitary axis and 4.5% in two or more axes. The most common disturbance was a decrease of testosterone in 40.7% of all men (in the following 13/131 men were given substitution therapy). Low fT4 was detected in 5.9% (n=3 were given substitution therapy). Low IGF-I was detected in 5.8%, low cortisol in 1.4%, and low prolactin in 0.2%; none were given substitution therapy. Further stimulation tests revealed growth hormone deficiency in 20.7% (n=19/92) and hypocortisolism in 23.7% (n=28/118). Laboratory values possibly indicating hypopituitarism (33%) were common but did not always implicate post-traumatic hypopituitarism. Laboratory values possibly indicating hypopituitarism were common in our screening but most patients were clinically not diagnosed as pituitary insufficient and did not receive hormone replacement therapy. A routine screening of all patients in neurorehabilitation without considering the time since injury, the severity of illness and therapeutic consequences seems not useful.

  1. Guidelines for the use and interpretation of nucleic acid detection tests for Neisseria gonorrhoeae in Australia: a position paper on behalf of the Public Health Laboratory Network.

    PubMed

    Smith, David W; Tapsall, John W; Lum, Gary

    2005-01-01

    The Public Health Laboratory Network (PHLN) convened a workshop of Australian experts in Melbourne on 23 March 2005 to identify laboratory issues of relevance and suggest guidelines for use of nucleic acid detection tests (NADT) for diagnosis of gonorrhoea in Australia. The proceedings of that meeting were endorsed by the members of the PHLN and the Communicable Diseases Network of Australia. Given the present state of knowledge and experience of conditions currently existing in Australia, the following recommendations were made: Recommendation 1: Assays using detection of the cppB gene should not be used for either screening or supplemental assays. Recommendation 2: All in-house screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 3: All commercial screening assays that are positive should also be positive on a reliable supplemental assay before a positive result is reported. Recommendation 4: If a sample is positive in a screening assay but a suitable supplemental assay is negative, then the result should be reported as negative. Recommendation 5: Laboratories should ensure that the test combination they use would yield a positive predictive value of at least 90 per cent in a population with a prevalence of 1 per cent. Recommendation 6: For the purposes of test evaluation, as distinct from diagnostic testing, true positives be defined by meeting one or more of the following criteria: 1) culture positive using contemporary isolation and identification techniques; 2) positive result on NADTs directed to targets on three separate genes that are known to have discriminatory capacity; 3) sequencing of a gene known to separate gonococcal from non-gonococcal species. Recommendation 7: Inhibitor controls should be routinely included in all NADT. Recommendation 8: Cultures are the preferred test for samples from non-genital sites. If however it is necessary to perform a NADT, then more stringent criteria should be applied, and positive samples should meet the 'test evaluation' criteria for a 'true positive'. Recommendation 9: In order to properly assess the routine diagnostic system in Australia, the following quality assurance samples should be distributed in addition to the routine samples currently used: 1. cppB negative N. gonorrhoeae; 2. Non-gonococcal species known to cause false positive reactions: these should be dispatched both as a single species, as well as mixture with N. gonorrhoeae. In the latter circumstance, the non-gonococcal species should be present in 10-fold excess; 3. Urine samples: preferably a single patient sample, otherwise a spiked sample. 4. Validation panels should be made that include samples that are culture positive but PCR negative. True positive samples should also be made available. In addition, a process should be established for full phenotypic and genotypic characterisation of unidentified species that yield false positive results in NADT for gonococci. Recommendation 10: Strategies should be put in place to ensure that sufficient numbers of gonococcal isolates are obtained to allow reliable monitoring of antimicrobial resistance. Recommendation 11: Public health practitioners need to define the relevant populations that need to be targeted and identify any that require enhanced surveillance.

  2. Test and training simulator for ground-based teleoperated in-orbit servicing

    NASA Technical Reports Server (NTRS)

    Schaefer, Bernd E.

    1989-01-01

    For the Post-IOC(In-Orbit Construction)-Phase of COLUMBUS it is intended to use robotic devices for the routine operations of ground-based teleoperated In-Orbit Servicing. A hardware simulator for verification of the relevant in-orbit operations technologies, the Servicing Test Facility, is necessary which mainly will support the Flight Control Center for the Manned Space-Laboratories for operational specific tasks like system simulation, training of teleoperators, parallel operation simultaneously to actual in-orbit activities and for the verification of the ground operations segment for telerobotics. The present status of definition for the facility functional and operational concept is described.

  3. Pyocin-sensitivity testing as a method of typing Pseudomonas aeruginosa: use of "phage-free" preparations of pyocin.

    PubMed

    Rampling, A; Whitby, J L; Wildy, P

    1975-11-01

    A method for pyocin-sensitivity typing by means of "phage-free" preparations of pyocin is described. The method was tested on 227 isolates of P. aeruginosa, collected from 34 different foci of infection in hospitals in the British Isles and the results were compared with those for combined serological and phage typing of all strains and pyocin production of 105 of the isolates. It is concluded that pyocin-sensitivity typing is a simple and reliable method giving a high degree of discrimination, comparable to that of combined serological and phage typing, and it is suitable for use in routine hospital laboratories.

  4. Multicenter Comparison of the Etest and EUCAST Methods for Antifungal Susceptibility Testing of Candida Isolates to Micafungin.

    PubMed

    Bougnoux, M-E; Dannaoui, E; Accoceberry, I; Angoulvant, A; Bailly, E; Botterel, F; Chevrier, S; Chouaki, T; Cornet, M; Dalle, F; Datry, A; Dupuis, A; Fekkar, A; Gangneux, J P; Guitard, J; Hennequin, C; Le Govic, Y; Le Pape, P; Maubon, D; Ranque, S; Sautour, M; Sendid, B; Chandenier, J

    2016-08-01

    In vitro susceptibility of 933 Candida isolates, from 16 French hospitals, to micafungin was determined using the Etest in each center. All isolates were then sent to a single center for determination of MICs by the EUCAST reference method. Overall essential agreement between the two tests was 98.5% at ±2 log2 dilutions and 90.2% at ±1 log2 dilutions. Categorical agreement was 98.2%. The Etest is a valuable alternative to EUCAST for the routine determination of micafungin MICs in medical mycology laboratories. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  5. Improved Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway

    DTIC Science & Technology

    2010-01-15

    information. 2.0 DESCRIPTION Naval Submarine Medical Research Laboratory (NSMRL) is seeking information from the eyewear industry that will provide...Improved Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway by Alison America, MA Wayne G. Horn, MD...Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway 50818 Alison America, MA Wayne G. Horn, MD Naval Submarine Medical Research

  6. Improved Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway

    DTIC Science & Technology

    2008-11-21

    Research Laboratory (NSMRL) is seeking information from the eyewear industry that will provide prescription eyewear frames for use when wearing an EAB...Improved Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway by Alison America, MA Wayne G. Horn, MD...Submariner Eyewear for Routine Wear and Emergency Equipment Use Underway Authors: Alison America, MA Wayne G. Horn, MD Naval Submarine Medical Research

  7. 7 CFR 94.3 - Analyses performed and locations of laboratories.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... applicable plant on the official certificate. (b) Mandatory egg product samples for Salmonella are required... recognized laboratories for analyzing routine egg product samples for Salmonella. (c) Mandatory egg product...

  8. Automation of the linear array HPV genotyping test and its application for routine typing of human papillomaviruses in cervical specimens of women without cytological abnormalities in Switzerland.

    PubMed

    Dobec, Marinko; Bannwart, Fridolin; Kaeppeli, Franz; Cassinotti, Pascal

    2009-05-01

    There is a need for reliable, automated high throughput HPV detection and genotyping methods for pre- and post-prophylactic vaccine intervention analyses. To optimize the linear array (LA) HPV genotyping test (Roche Diagnostics, Rotkreuz) in regard to possible automation steps for the routine laboratory diagnosis of HPV infections and to analyze the HPV genotype distribution in cervical specimens of women without cytological abnormalities in Switzerland. 680 cervical cell specimens with normal cytology, obtained from women undergoing routine cervical screening by liquid-based Pap smear, were analyzed by the LA HPV genotyping test for HPV-DNA. The automation of the LA HPV genotyping test resulted in a total hands-on time reduction of 255 min (from 480 to 225 min; 53%). Any of 37 HPV genotypes were detected in 117 (17.2%) and high-risk (HR) HPV in 55 (8.1%) of 680 women with normal cytology. The highest prevalence of any HPV (28.1%) and HR-HPV (15.1%) was observed in age-group 21-30 and showed a continuous decrease in older age-groups. The most common HR-HPV genotypes were HPV-16 (12%), HPV-31 (9.4%), HPV-52 (6%), HPV-51 (5.1%), HPV-45 (4.3%), HPV-58 (4.3%) and HPV-59 (4.3%). The optimization and automation of the LA HPV genotyping test makes it suited for high throughput HPV detection and typing. The epidemiological data provides information about distribution of HPV genotypes in women without cytological abnormalities in Switzerland and may be important for determining the future impact of vaccines and potential changes in the country's epidemiological HPV profile.

  9. Challenges in Routine Implementation and Quality Control of Rapid Diagnostic Tests for Malaria–Rufiji District, Tanzania

    PubMed Central

    McMorrow, Meredith L.; Masanja, M. Irene; Abdulla, Salim M. K.; Kahigwa, Elizeus; Kachur, S. Patrick

    2018-01-01

    Rapid diagnostic tests (RDTs) represent an alternative to microscopy for malaria diagnosis and have shown high sensitivity and specificity in a variety of study settings. Current World Health Organization (WHO) guidelines for quality control of RDTs provide detailed instructions on pre-field testing, but offer little guidance for quality assurance once RDTs are deployed in health facilities. From September 2006 to April 2007, we introduced a histidine-rich protein II (HRP2)-based RDT (Paracheck) for suspected malaria cases five years of age and older in nine health facilities in Rufiji District, Tanzania, to assess sensitivity and specificity of RDTs in routine use at rural health facilities. Thick blood smears were collected for all patients tested with RDTs and stained and read by laboratory personnel in each facility. Thick smears were subsequently reviewed by a reference microscopist to determine RDT sensitivity and specificity. In all nine health facilities, there were significant problems with the quality of staining and microscopy. Sensitivity and specificity of RDTs were difficult to assess given the poor quality of routine blood smear staining. Mean operational sensitivity of RDTs based on reference microscopy was 64.8%, but varied greatly by health facility, range 18.8–85.9%. Sensitivity of RDTs increased with increasing parasite density. Specificity remained high at 87.8% despite relatively poor slide quality. Institution of quality control of RDTs based on poor quality blood smear staining may impede reliable measurement of sensitivity and specificity and undermine confidence in the new diagnostic. There is an urgent need for the development of alternative quality control procedures for rapid diagnostic tests that can be performed at the facility level. PMID:18784230

  10. C-reactive protein for the early prediction of anastomotic leak after esophagectomy in both neoadjuvant and non-neoadjuvant therapy case: a propensity score matching analysis.

    PubMed

    Park, Jae Kil; Kim, Jae Jun; Moon, Seok Whan

    2017-10-01

    Anastomotic leak is one of most significant causes of mortality after esophagectomy. Therefore, it is clinically valuable to detect anastomotic leak early after esophagectomy in esophageal cancer. The purpose of this study is to investigate the associations between routine postoperative laboratory findings and anastomotic leak and to analyze the laboratory findings to find out an independent predictive marker for anastomotic leak. In addition, this study compares cases treated with neoadjuvant therapy (NT) and those without (non-NT). We retrospectively assessed the medical records of 201 consecutive cases that met this study's criteria from January 2009 to December 2016. All patients underwent curative and complete esophagectomy for intra-thoracic esophageal cancer. We compiled and analyzed routine laboratory findings from the day before surgery to the eighth postoperative day on a daily basis. Routine laboratory tests consisted of 26 separate tests, including complete blood cell counts, blood chemistries, as well as erythrocyte sedimentation rate and C-reactive protein (CRP). Barium esophagogram with chest computed tomography (CT) was performed on the seventh postoperative day to evaluate the presence of an anastomotic leak. A total of 45 of 201 patients underwent NT. Anastomotic leaks were found in 23 (11.4%) of 201 patients (8 patients in NT and 15 patients in non-NT). White blood cell (WBC) from the second postoperative day (P=0.031, P=0.006, P=0.007, P=0.007, P=0.041, and P=0.003, respectively) and CRP from the third postoperative day (P=0.012, P<0.001, P=0.014, P<0.001, P=0.001, and P=0.006, respectively) were associated with anastomotic leak in non-NT; however, only CRP on the third, fifth, sixth, and seventh postoperative days (P=0.041, P=0.037, P=0.002, and P=0.003, respectively) was associated with anastomotic leak in NT. The CRP level on the third postoperative day was a significant independent predictive marker of anastomotic leak (P=0.041, odd ratio (OR) 1.056, 95% confidential interval (CI): 1.002-1.113) and had a significant diagnostic cutoff value for the development of anastomotic leak (non-NT: cutoff value 17.12 mg/dL, sensitivity 69.2%, specificity 78.1%, P<0.001, area 0.822; NT: cutoff value 16.42 mg/dL, sensitivity 80.0%, specificity 70.0%, P=0.042, area 0.7104). There were divergent laboratory findings reflective of anastomotic leak between patients who underwent NT and those who did not. The CRP level on the third postoperative day had a significant cutoff value for early detection of anastomotic leak after esophagectomy in both NT and non-NT groups.

  11. Multiple pre- and post-analytical lean approaches to the improvement of the laboratory turnaround time in a large core laboratory.

    PubMed

    Lou, Amy H; Elnenaei, Manal O; Sadek, Irene; Thompson, Shauna; Crocker, Bryan D; Nassar, Bassam A

    2017-10-01

    Core laboratory (CL), as a new business model, facilitates consolidation and integration of laboratory services to enhance efficiency and reduce costs. This study evaluates the impact of total laboratory automation system (TLA), electric track vehicle (ETV) system and auto-verification (AV) of results on overall turnaround time (TAT) (phlebotomy to reporting TAT: PR-TAT) within a CL setting. Mean, median and percentage of outlier (OP) for PR-TAT were compared for pre- and post-CL eras using five representative tests based on different request priorities. Comparison studies were also carried out on the intra-laboratory TAT (in-lab to reporting TAT: IR-TAT) and the delivery TAT (phlebotomy to in-lab TAT: PI-TAT) to reflect the efficiency of the TLA (both before and after introducing result AV) and ETV systems respectively. Median PR-TATs for the urgent samples were reduced on average by 16% across all representative analytes. Median PR-TATs for the routine samples were curtailed by 51%, 50%, 49%, 34% and 22% for urea, potassium, thyroid stimulating hormone (TSH), complete blood count (CBC) and prothrombin time (PT) respectively. The shorter PR-TAT was attributed to a significant reduction of IR-TAT through the TLA. However, the median PI-TAT was delayed when the ETV was used. Application of various AV rules shortened the median IR-TATs for potassium and urea. However, the OP of PR-TAT for the STAT requests exceeding 60min were all higher than those from the pre-CL era. TLA and auto-verification rules help to efficiently manage substantial volumes of urgent and routine samples. However, the ETV application as it stands shows a negative impact on the PR-TAT. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. Soil examination for a forensic trace evidence laboratory-Part 3: A proposed protocol for the effective triage and management of soil examinations.

    PubMed

    Woods, Brenda; Lennard, Chris; Kirkbride, K Paul; Robertson, James

    2016-05-01

    In the past, forensic soil examination was a routine aspect of forensic trace evidence examinations. The apparent need for soil examinations then went through a period of decline and with it the capability of many forensic laboratories to carry out soil examinations. In more recent years, interest in soil examinations has been renewed due-at least in part-to soil examinations contributing to some high profile investigations. However, much of this renewed interest has been in organisations with a primary interest in soil and geology rather than forensic science. We argue the need to reinstate soil examinations as a trace evidence sub-discipline within forensic science laboratories and present a pathway to support this aim. An examination procedure is proposed that includes: (i) appropriate sample collection and storage by qualified crime scene examiners; (ii) exclusionary soil examinations by trace evidence scientists within a forensic science laboratory; (iii) inclusionary soil examinations by trace evidence scientists within a forensic science laboratory; and (iv) higher-level examination of soils by specialist soil scientists and palynologists. Soil examinations conducted by trace evidence scientists will be facilitated if the examinations are conducted using the instrumentation routinely used by these examiners. Hence, the proposed examination protocol incorporates instrumentation in routine use in a forensic trace evidence laboratory. Finally, we report on an Australian soil scene variability study and a blind trial that demonstrate the utility of the proposed protocol for the effective triage and management of soil samples by forensic laboratories. Crown Copyright © 2016. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Establishing a cost-per-result of laboratory-based, reflex Cryptococcal antigenaemia screening (CrAg) in HIV+ patients with CD4 counts less than 100 cells/μl using a Lateral Flow Assay (LFA) at a typical busy CD4 laboratory in South Africa.

    PubMed

    Cassim, Naseem; Schnippel, Kathryn; Coetzee, Lindi Marie; Glencross, Deborah Kim

    2017-01-01

    Cryptococcal meningitis is a major cause of mortality and morbidity in countries with high HIV prevalence, primarily affecting patients whose CD4 are < = 100 cells/μl. Routine Cryptococcal Antigen (CrAg) screening is thus recommended in the South African HIV treatment guidelines for all patients with CD4 counts < = 100 cells/μl, followed by pre-emptive anti-fungal therapy where CrAg results are positive. A laboratory-based reflexed CrAg screening approach, using a Lateral Flow Assay (LFA) on remnant EDTA CD4 blood samples, was piloted at three CD4 laboratories. This study aimed to assess the cost-per-result of laboratory-based reflexed CrAg screening at one pilot CD4 referral laboratory. CD4 test volumes from 2014 were extracted to estimate percentage of CD4 < = 100 cells/μl. Daily average volumes were derived, assuming 12 months per/year and 21.73 working days per/month. Costing analyses were undertaken using Microsoft Excel and Stata with a provider prospective. The cost-per-result was estimated using a bottom-up method, inclusive of test kits and consumables (reagents), laboratory equipment and technical effort costs. The ZAR/$ exchange of 14.696/$1 was used, where applicable. One-way sensitivity analyses on the cost-per-result were conducted for possible error rates (3%- 8%, reductions or increases in reagent costs as well as test volumes (ranging from -60% to +60%). The pilot CD4 laboratory performed 267000 CD4 tests in 2014; ~ 9.3% (27500) reported CD4< = 100 cells/μl, equivalent to 106 CrAg tests performed daily. A batch of 30-tests could be performed in 1.6 hours, including preparation and analysis time. A cost-per-result of $4.28 was reported, with reagents contributing $3.11 (72.8%), while technical effort and laboratory equipment overheads contributed $1.17 (27.2%) and $0.03 (<1%) respectively. One-way sensitivity analyses including increasing or decreasing test volumes by 60% revealed a cost-per-result range of $3.84 to $6.03. A cost-per-result of $4.28 was established in a typical CD4 service laboratory to enable local budgetary cost projections and programmatic cost-effectiveness modelling. Varying reagent costs linked to currency exchange and varying test volumes in different levels of service can lead to varying cost-per-test and technical effort to manage workload, with an inverse relationship of higher costs expected at lower volumes of tests.

  14. Achieving across-laboratory replicability in psychophysical scaling

    PubMed Central

    Ward, Lawrence M.; Baumann, Michael; Moffat, Graeme; Roberts, Larry E.; Mori, Shuji; Rutledge-Taylor, Matthew; West, Robert L.

    2015-01-01

    It is well known that, although psychophysical scaling produces good qualitative agreement between experiments, precise quantitative agreement between experimental results, such as that routinely achieved in physics or biology, is rarely or never attained. A particularly galling example of this is the fact that power function exponents for the same psychological continuum, measured in different laboratories but ostensibly using the same scaling method, magnitude estimation, can vary by a factor of three. Constrained scaling (CS), in which observers first learn a standardized meaning for a set of numerical responses relative to a standard sensory continuum and then make magnitude judgments of other sensations using the learned response scale, has produced excellent quantitative agreement between individual observers’ psychophysical functions. Theoretically it could do the same for across-laboratory comparisons, although this needs to be tested directly. We compared nine different experiments from four different laboratories as an example of the level of across experiment and across-laboratory agreement achievable using CS. In general, we found across experiment and across-laboratory agreement using CS to be significantly superior to that typically obtained with conventional magnitude estimation techniques, although some of its potential remains to be realized. PMID:26191019

  15. Comparison of Saramis 4.12 and IVD 3.0 Vitek MS Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry for Identification of Mycobacteria from Solid and Liquid Culture Media

    PubMed Central

    Leyer, Caroline; Gregorowicz, Guillaume; Mougari, Faiza; Raskine, Laurent; Cambau, Emmanuelle

    2017-01-01

    ABSTRACT During the last decade, many investigators have studied matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) for identification of mycobacteria. Diverse and contradictory results indicated that optimal level for routine testing has not been reached yet. This work aimed to assess Vitek MS through two distinct versions, Saramis v4.12 RUO and the IVD v3.0, under conditions close to routine laboratory practice. Overall, 111 mycobacterial isolates were subjected to protein extraction and same spectra were matched against both databases. The IVD v3.0 database proved to be superior to Saramis v4.12 and its identification rates remarkably increased, from 67% to 94% for isolates grown on Middlebrook 7H10 solid medium and from 62% to 91% for isolates grown on mycobacterial growth indicator tube (MGIT) liquid medium. With this new version, IVD v3.0, MALDI-TOF MS might be integrated into routine clinical diagnostics, although molecular techniques remain mandatory in some cases. PMID:28424252

  16. Benchmarking and the laboratory

    PubMed Central

    Galloway, M; Nadin, L

    2001-01-01

    This article describes how benchmarking can be used to assess laboratory performance. Two benchmarking schemes are reviewed, the Clinical Benchmarking Company's Pathology Report and the College of American Pathologists' Q-Probes scheme. The Clinical Benchmarking Company's Pathology Report is undertaken by staff based in the clinical management unit, Keele University with appropriate input from the professional organisations within pathology. Five annual reports have now been completed. Each report is a detailed analysis of 10 areas of laboratory performance. In this review, particular attention is focused on the areas of quality, productivity, variation in clinical practice, skill mix, and working hours. The Q-Probes scheme is part of the College of American Pathologists programme in studies of quality assurance. The Q-Probes scheme and its applicability to pathology in the UK is illustrated by reviewing two recent Q-Probe studies: routine outpatient test turnaround time and outpatient test order accuracy. The Q-Probes scheme is somewhat limited by the small number of UK laboratories that have participated. In conclusion, as a result of the government's policy in the UK, benchmarking is here to stay. Benchmarking schemes described in this article are one way in which pathologists can demonstrate that they are providing a cost effective and high quality service. Key Words: benchmarking • pathology PMID:11477112

  17. Quality Improvement Intervention for Reduction of Redundant Testing.

    PubMed

    Ducatman, Alan M; Tacker, Danyel H; Ducatman, Barbara S; Long, Dustin; Perrotta, Peter L; Lawther, Hannah; Pennington, Kelly; Lander, Owen; Warden, Mary; Failinger, Conard; Halbritter, Kevin; Pellegrino, Ronald; Treese, Marney; Stead, Jeffrey A; Glass, Eric; Cianciaruso, Lauren; Nau, Konrad C

    2017-01-01

    Laboratory data are critical to analyzing and improving clinical quality. In the setting of residual use of creatine kinase M and B isoenzyme testing for myocardial infarction, we assessed disease outcomes of discordant creatine kinase M and B isoenzyme +/troponin I (-) test pairs in order to address anticipated clinician concerns about potential loss of case-finding sensitivity following proposed discontinuation of routine creatine kinase and creatine kinase M and B isoenzyme testing. Time-sequenced interventions were introduced. The main outcome was the percentage of cardiac marker studies performed within guidelines. Nonguideline orders dominated at baseline. Creatine kinase M and B isoenzyme testing in 7496 order sets failed to detect additional myocardial infarctions but was associated with 42 potentially preventable admissions/quarter. Interruptive computerized soft stops improved guideline compliance from 32.3% to 58% ( P < .001) in services not receiving peer leader intervention and to >80% ( P < .001) with peer leadership that featured dashboard feedback about test order performance. This successful experience was recapitulated in interrupted time series within 2 additional services within facility 1 and then in 2 external hospitals (including a critical access facility). Improvements have been sustained postintervention. Laboratory cost savings at the academic facility were estimated to be ≥US$635 000 per year. National collaborative data indicated that facility 1 improved its order patterns from fourth to first quartile compared to peer norms and imply that nonguideline orders persist elsewhere. This example illustrates how pathologists can provide leadership in assisting clinicians in changing laboratory ordering practices. We found that clinicians respond to local laboratory data about their own test performance and that evidence suggesting harm is more compelling to clinicians than evidence of cost savings. Our experience indicates that interventions done at an academic facility can be readily instituted by private practitioners at external facilities. The intervention data also supplement existing literature that electronic order interruptions are more successful when combined with modalities that rely on peer education combined with dashboard feedback about laboratory order performance. The findings may have implications for the role of the pathology laboratory in the ongoing pivot from quantity-based to value-based health care.

  18. Coverage of neonatal screening: failure of coverage or failure of information system

    PubMed Central

    Ades, A; Walker, J; Jones, R; Smith, I

    2001-01-01

    OBJECTIVES—To evaluate neonatal screening coverage using data routinely collected on the laboratory computer.
SUBJECTS—90 850 births in 14 North East Thames community provider districts over a 21 month period.
METHODS—Births notified to local child health computers are electronically copied to the neonatal laboratory computer system, and incoming Guthrie cards are matched against these birth records before testing. The computer records for the study period were processed to estimate the coverage of the screening programme.
RESULTS—Out of an estimated 90 850 births notified to child health computers, all but 746 (0.82%) appeared to have been screened or could be otherwise accounted for (0.14% in non-metropolitan districts, 0.39% in suburban districts, and 1.68% in inner city districts). A further 893 resident infants had been tested, but could not be matched to the list of notified resident births. The calculated programme coverage already exceeds the 99.5% National Audit Programme standard in 7/14 districts. Elsewhere it is not clear whether it is coverage or recording of coverage that is low.
CONCLUSION—Previous reports of low coverage may have been exaggerated. High coverage can be shown using routine information systems. Design of information systems that deliver accurate measures of coverage would be more useful than comparison of inadequately measured coverage with a national standard. The new NHS number project will create an opportunity to achieve this.
 PMID:11369561

  19. Bacterial genome sequencing in clinical microbiology: a pathogen-oriented review.

    PubMed

    Tagini, F; Greub, G

    2017-11-01

    In recent years, whole-genome sequencing (WGS) has been perceived as a technology with the potential to revolutionise clinical microbiology. Herein, we reviewed the literature on the use of WGS for the most commonly encountered pathogens in clinical microbiology laboratories: Escherichia coli and other Enterobacteriaceae, Staphylococcus aureus and coagulase-negative staphylococci, streptococci and enterococci, mycobacteria and Chlamydia trachomatis. For each pathogen group, we focused on five different aspects: the genome characteristics, the most common genomic approaches and the clinical uses of WGS for (i) typing and outbreak analysis, (ii) virulence investigation and (iii) in silico antimicrobial susceptibility testing. Of all the clinical usages, the most frequent and straightforward usage was to type bacteria and to trace outbreaks back. A next step toward standardisation was made thanks to the development of several new genome-wide multi-locus sequence typing systems based on WGS data. Although virulence characterisation could help in various particular clinical settings, it was done mainly to describe outbreak strains. An increasing number of studies compared genotypic to phenotypic antibiotic susceptibility testing, with mostly promising results. However, routine implementation will preferentially be done in the workflow of particular pathogens, such as mycobacteria, rather than as a broadly applicable generic tool. Overall, concrete uses of WGS in routine clinical microbiology or infection control laboratories were done, but the next big challenges will be the standardisation and validation of the procedures and bioinformatics pipelines in order to reach clinical standards.

  20. Clinical validity of delayed recall tests as a gateway biomarker for Alzheimer's disease in the context of a structured 5-phase development framework.

    PubMed

    Cerami, Chiara; Dubois, Bruno; Boccardi, Marina; Monsch, Andreas U; Demonet, Jean Francois; Cappa, Stefano F

    2017-04-01

    Although Alzheimer's disease criteria promote the use of biomarkers, their maturity in clinical routine still needs to be assessed. In the light of the oncology framework, we conducted a literature review on measures used to assess delayed recall impairment due to medial temporal lobe dysfunction (i.e., free and cued word list recall tests). Ample evidence is available for phases 1 (rationale for use), 2 (discriminative ability), and 3 (early detection ability) for many of the tests in routine use. Evidence about phase 4 (performance in real world) and phase 5 (quantify impact and costs) is yet to come. Administration procedures have been standardized and cutoff scores are well validated in large Alzheimer's disease and mild cognitive impaired series. Some aspects (e.g., different task formats), however, hamper the comparability of results among different populations and the reproducibility between laboratories. No definite guideline for their use can thus be proposed at the moment. Accordingly, the maturity of such markers is not yet sufficient and requires future investigation to promote the proper use of memory measures in clinical settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Sodium citrate vacuum tubes validation: preventing preanalytical variability in routine coagulation testing.

    PubMed

    Lima-Oliveira, Gabriel; Lippi, Giuseppe; Salvagno, Gian Luca; Montagnana, Martina; Picheth, Geraldo; Guidi, Gian Cesare

    2013-04-01

    Sometimes in-vitro diagnostic devices (e.g. blood collection tubes) are not validated before use or when the producer's brand is changed. The aim of this study was to validate five brands of sodium citrate vacuum tubes. Blood specimens from 50 volunteers were collected in five different tube brands (I: Venosafe, II: VACUETTE, III: BD Vacutainer, IV: LABOR IMPORT and V: S-Monovette). Routine coagulation tests [activated partial thromboplastin time (aPTT), prothrombin time (PT), and fibrinogen (FIB)] were performed on ACL TOP instrument using HemosIL reagents. The significance of the differences between samples was assessed by paired Student's t-test, set at P < 0.005. Significant differences were observed for: PT when comparing I vs. II, I vs. III, I vs. V, II vs. III, II vs. IV, II vs. V, III vs. IV, III vs. V and IV vs. V; aPTT when comparing I vs. II, I vs. III, I vs. IV, II vs. IV, III vs. IV and IV vs. V. No differences were observed among brands for FIB determination. We suggest that every laboratory management should both standardize the procedures and frequently evaluate the quality of in-vitro diagnostic devices.

  2. Qualitative and quantitative observations of bone tissue reactions to anodised implants.

    PubMed

    Sul, Young-Taeg; Johansson, Carina B; Röser, Kerstin; Albrektsson, Tomas

    2002-04-01

    Research projects focusing on biomaterials related factors; the bulk implant material, the macro-design of the implant and the microsurface roughness are routinely being conducted at our laboratories. In this study, we have investigated the bone tissue reactions to turned commercially pure (c.p.) titanium implants with various thicknesses of the oxide films after 6 weeks of insertion in rabbit bone. The control c.p. titanium implants had an oxide thickness of 17-200 nm while the test implants revealed an oxide thickness between 600 and 1000 nm. Routine histological investigations of the tissue reactions around the implants and enzyme histochemical detections of alkaline and acid phosphatase activities demonstrated similar findings around both the control and test implants. In general, the histomorphometrical parameters (bone to implant contact and newly formed bone) revealed significant quantitative differences between the control and test implants. The test implants demonstrated a greater bone response histomorphometrically than control implants and the osteoconductivity was more pronounced around the test implant surfaces. The parameters that differed between the implant surfaces, i.e. the oxide thickness, the pore size distribution, the porosity and the crystallinity of the surface oxides may represent factors that have an influence on the histomorphometrical results indicated by a stronger bone tissue response to the test implant surfaces, with an oxide thickness of more than 600 nm.

  3. Performance of a Highly Sensitive Mycobacterium tuberculosis Complex Real-Time PCR Assay for Diagnosis of Pulmonary Tuberculosis in a Low-Prevalence Setting: a Prospective Intervention Study.

    PubMed

    Vinuesa, Víctor; Borrás, Rafael; Briones, María Luisa; Clari, María Ángeles; Cresencio, Vicenta; Giménez, Estela; Muñoz, Carmen; Oltra, Rosa; Servera, Emilio; Scheelje, Talia; Tornero, Carlos; Navarro, David

    2018-05-01

    The potential impact of routine real-time PCR testing of respiratory specimens from patients with presumptive tuberculosis in terms of diagnostic accuracy and time to tuberculosis treatment inception in low-prevalence settings remains largely unexplored. We conducted a prospective intervention cohort study. Respiratory specimens from 1,020 patients were examined by acid-fast bacillus smear microscopy, tested by a real-time Mycobacterium tuberculosis complex PCR assay (Abbott RealTi me MTB PCR), and cultured in mycobacterial media. Seventeen patients tested positive by PCR (5 were acid-fast bacillus smear positive and 12 acid-fast bacillus smear negative), and Mycobacterium tuberculosis was recovered from cultures for 12 of them. Patients testing positive by PCR and negative by culture ( n = 5) were treated and deemed to have responded to antituberculosis therapy. There were no PCR-negative/culture-positive cases, and none of the patients testing positive for nontuberculous mycobacteria ( n = 20) yielded a positive PCR result. The data indicated that routine testing of respiratory specimens from patients with presumptive tuberculosis by the RealTi me MTB PCR assay improves the tuberculosis diagnostic yield and may reduce the time to antituberculosis treatment initiation. On the basis of our data, we propose a novel mycobacterial laboratory algorithm for tuberculosis diagnosis. Copyright © 2018 American Society for Microbiology.

  4. Routine Digital Pathology Workflow: The Catania Experience

    PubMed Central

    Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana

    2017-01-01

    Introduction: Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. Methods: All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Results: Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Conclusion: Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory. PMID:29416914

  5. Routine Digital Pathology Workflow: The Catania Experience.

    PubMed

    Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana

    2017-01-01

    Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory.

  6. Check-off logs for routine equipment maintenance.

    PubMed

    Brewster, M A; Carver, P H; Randolph, B

    1995-12-01

    The regulatory requirement for appropriate routine instrument maintenance documentation is approached by laboratories in numerous ways. Standard operating procedures (SOPs) may refer to maintenance listed in instrument manuals, may indicate "periodic" performance of an action, or may indicate specific tasks to be performed at certain frequencies. The Quality Assurance Unit (QAU) task of assuring the performance of these indicated maintenance tasks can be extremely laborious if these records are merged with other analysis records. Further, the lack of written maintenance schedules often leads to omission of infrequently performed tasks. We recommend creation of routine maintenance check-off logs for instruments with tasks grouped by frequency of expected performance. Usage of such logs should result in better laboratory compliance with SOPs and the compliance can be readily monitored by QAU or by regulatory agencies.

  7. Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays.

    PubMed

    Le Quellec, Sandra; Paris, Mickaël; Nougier, Christophe; Sobas, Frédéric; Rugeri, Lucia; Girard, Sandrine; Bordet, Jean-Claude; Négrier, Claude; Dargaud, Yesim

    2017-05-01

    Pneumatic tube system (PTS) in hospitals is commonly used for the transport of blood samples to clinical laboratories, as it is rapid and cost-effective. The aim was to compare the effects on haematology samples of a newly acquired ~2km-long PTS that links 2 hospitals with usual transport (non-pneumatic tube system, NPTS). Complete blood cell count, routine coagulation assays, platelet function tests (PFT) with light-transmission aggregometry and global coagulation assays including ROTEM® and thrombin generation assay (TGA) were performed on blood samples from 30 healthy volunteers and 9 healthy volunteers who agreed to take aspirin prior to blood sampling. The turnaround time was reduced by 31% (p<0.001) with the use of PTS. No statistically significant difference was observed for most routine haematology assays including PFT, and ROTEM® analysis. A statistically significant, but not clinically relevant, shortening of the APTT after sample transport by PTS was found (mean±SD: 30s±1.8 vs. 29.5s±2.1 for NPTS). D-dimer levels were 7.4% higher after transport through PTS but were not discordant. A statistically significant increase of thrombin generation was found in both platelet poor- and platelet rich- plasma samples after PTS transport compared to NPTS transport. PTS is suitable for the transport of samples prior to routine haematology assays including PFT, but should not be used for samples intended for thrombin generation measurement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Feline focus: Diagnostic testing for feline thyroid disease: hyperthyroidism.

    PubMed

    Peterson, Mark E

    2013-08-01

    In older cats presenting with clinical features of hyperthyroidism, confirming the diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests, especially when used for routine screening of large numbers of asymptomatic cats. Therefore, all thyroid function test results must be interpreted in light of the cat's history, clinical signs, and other laboratory findings. If a high serum thyroxine (T4) value is found in a cat that lacks clinical signs of hyperthyroidism, or if hyperthyroidism is suspected in a cat with normal total T4 concentrations, repeating the total T4 analysis, determining the free T4 concentration, or performing thyroid scintigraphy may be needed to confirm the diagnosis.

  9. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiationmore » testing of carbon nanotube field effect transistor will be discussed.« less

  10. High risk of false positive results in a widely used diagnostic test for detection of the porcine reproductive and respiratory syndrome virus (PRRSV).

    PubMed

    Fetzer, C; Pesch, S; Ohlinger, V F

    2006-06-15

    During 2003 and 2004, increasing numbers of positive PRRSV RT-PCR results were reported from herds negative for PRRSV infection. Interestingly, three herds represent nucleus herds with no animal contacts from outside and without clinical symptoms of PRRS until now. Since these positive results that were obtained using a PCR protocol adapted to routine laboratory conditions could not be reproduced with other PRRSV specific RT-PCRs, controlled negative and positive samples were used to examine this phenomenon. A RT-PCR assay for detection and differential diagnosis of the European and North American genotypes of the porcine reproductive and respiratory syndrome virus (PRRSV) according to the method previously published by Oleksiewicz et al. [Oleksiewicz, M.B., Botner, A., Madsen, K.G., Storgaard, T., 1998. Sensitive detection and typing of porcine reproductive and respiratory syndrome virus by RT-PCR amplification of whole viral genes. Vet. Microbiol. 64, 7-22] was investigated in parallel to another recently published method [Pesch, S., 2003. Etablierung einer Nachweismethode für die zwei Genotypen von dem porcine reproductive and respiratory syndrome virus (PRRSV) und ein Beitrag zu seiner molekularen Epidemiologie. Thesis, Institute of Virology, Faculty of Veterinary Medicine, University of Leipzig]. A panel of 228 clinical samples sent in for PRRSV routine diagnostics served as test panel. It was found that both methods have similar analytical sensitivity. However, the primers published by Oleksiewicz were shown to yield a very high proportion of false positive results under routine diagnostic laboratory conditions, i.e. they resulted in RT-PCR products with non-PRRSV sequences, that were indistinguishable from truly positive reagents in standard gel electrophoresis settings. The reason for and possible implications of this finding as well as the risk of modifying published methods without control are discussed.

  11. [Nephro-urological monitoring technology based on radionuclide functional tests (tasks of an automated workplace)].

    PubMed

    Averinova, S G; Kashkadaeva, A V; Shiriaev, S V; Nechipaĭ, A M; Dmitrieva, G D

    1999-01-01

    The paper deals with a diagnostic informational and analytical system (DIAS). The system is based on the current concept of a dynamic model of nephro-urological clearance macroregulation under retention factors at the pre-, intra-, and postrenal levels during drug load tests. DIAS includes a package of dynamic renoscintigraphic techniques, as well as original software support. A system for parameters of renal clearance regulation has been developed, which is effective at nephro-urological screening and monitoring at all treatment stages for cancer patients. A two-detector chamber which permits the mounting of a detector at an angle to the patient's body is the optimum diagnostic apparatus for a cancer clinic. The use of functional tests makes it possible to examine the regulatory reserves for each kidney, followed up by the choice of adequate corrective measures to prevent renal failure during treatment. In some cases, DIAS monitoring frequently shows a higher sensitivity to the signs of latent renal failure than does routine clinical and laboratory monitoring. The effective radiation dose taken by a patient during a study by the DIAS technology aimed at reducing radioopaque doses is 100-150 times higher than that at an X-ray study and is an order less than during routine urinary tests.

  12. Smart management of sample dilution using an artificial neural network to achieve streamlined processes and saving resources: the automated nephelometric testing of serum free light chain as case study.

    PubMed

    Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio

    2017-02-01

    Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.

  13. Marine Sciences Laboratory Radionuclide Air Emissions Report for Calendar Year 2015

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Sandra F.; Barnett, J. Matthew

    2016-05-05

    The U.S. Department of Energy Office of Science (DOE-SC) Pacific Northwest Site Office has oversight and stewardship duties associated with the Pacific Northwest National Laboratory Marine Sciences Laboratory located on Battelle Land – Sequim. This report is prepared to document compliance with the 40 CFR Part 61, Subpart H, “National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities” and Washington Administrative Code . The EDE to the MSL MEI due to routine operations in 2015 was 1.1E-04 mrem (1.1E-06 mSv). No non-routine emissions occurred in 2015. The MSL is in compliance with the federalmore » and state 10 mrem/yr standard.« less

  14. Validation of a new ELISA method for in vitro potency testing of hepatitis A vaccines.

    PubMed

    Morgeaux, S; Variot, P; Daas, A; Costanzo, A

    2013-01-01

    The goal of the project was to standardise a new in vitro method in replacement of the existing standard method for the determination of hepatitis A virus antigen content in hepatitis A vaccines (HAV) marketed in Europe. This became necessary due to issues with the method used previously, requiring the use of commercial test kits. The selected candidate method, not based on commercial kits, had already been used for many years by an Official Medicines Control Laboratory (OMCL) for routine testing and batch release of HAV. After a pre-qualification phase (Phase 1) that showed the suitability of the commercially available critical ELISA reagents for the determination of antigen content in marketed HAV present on the European market, an international collaborative study (Phase 2) was carried out in order to fully validate the method. Eleven laboratories took part in the collaborative study. They performed assays with the candidate standard method and, in parallel, for comparison purposes, with their own in-house validated methods where these were available. The study demonstrated that the new assay provides a more reliable and reproducible method when compared to the existing standard method. A good correlation of the candidate standard method with the in vivo immunogenicity assay in mice was shown previously for both potent and sub-potent (stressed) vaccines. Thus, the new standard method validated during the collaborative study may be implemented readily by manufacturers and OMCLs for routine batch release but also for in-process control or consistency testing. The new method was approved in October 2012 by Group of Experts 15 of the European Pharmacopoeia (Ph. Eur.) as the standard method for in vitro potency testing of HAV. The relevant texts will be revised accordingly. Critical reagents such as coating reagent and detection antibodies have been adopted by the Ph. Eur. Commission and are available from the EDQM as Ph. Eur. Biological Reference Reagents (BRRs).

  15. Estimating rotavirus gastroenteritis hospitalisations by using hospital episode statistics before and after the introduction of rotavirus vaccine in Australia.

    PubMed

    Jayasinghe, Sanjay; Macartney, Kristine

    2013-01-30

    Hospital discharge records and laboratory data have shown a substantial early impact from the rotavirus vaccination program that commenced in 2007 in Australia. However, these assessments are affected by the validity and reliability of hospital discharge coding and stool testing to measure the true incidence of hospitalised disease. The aim of this study was to assess the validity of these data sources for disease estimation, both before and after, vaccine introduction. All hospitalisations at a major paediatric centre in children aged <5 years from 2000 to 2009 containing acute gastroenteritis (AGE) ICD 10 AM diagnosis codes were linked to hospital laboratory stool testing data. The validity of the rotavirus-specific diagnosis code (A08.0) and the incidence of hospitalisations attributable to rotavirus by both direct estimation and with adjustments for non-testing and miscoding were calculated for pre- and post-vaccination periods. A laboratory record of stool testing was available for 36% of all AGE hospitalisations (n=4948) the rotavirus code had high specificity (98.4%; 95% CI, 97.5-99.1%) and positive predictive value (96.8%; 94.8-98.3%), and modest sensitivity (61.6%; 58-65.1%). Of all rotavirus test positive hospitalisations only a third had a rotavirus code. The estimated annual average number of rotavirus hospitalisations, following adjustment for non-testing and miscoding was 5- and 6-fold higher than identified, respectively, from testing and coding alone. Direct and adjusted estimates yielded similar percentage reductions in annual average rotavirus hospitalisations of over 65%. Due to the limited use of stool testing and poor sensitivity of the rotavirus-specific diagnosis code routine hospital discharge and laboratory data substantially underestimate the true incidence of rotavirus hospitalisations and absolute vaccine impact. However, this data can still be used to monitor vaccine impact as the effects of miscoding and under-testing appear to be comparable between pre and post vaccination periods. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Quality assurance and quality control for thermal/optical analysis of aerosol samples for organic and elemental carbon.

    PubMed

    Chow, Judith C; Watson, John G; Robles, Jerome; Wang, Xiaoliang; Chen, L-W Antony; Trimble, Dana L; Kohl, Steven D; Tropp, Richard J; Fung, Kochy K

    2011-12-01

    Accurate, precise, and valid organic and elemental carbon (OC and EC, respectively) measurements require more effort than the routine analysis of ambient aerosol and source samples. This paper documents the quality assurance (QA) and quality control (QC) procedures that should be implemented to ensure consistency of OC and EC measurements. Prior to field sampling, the appropriate filter substrate must be selected and tested for sampling effectiveness. Unexposed filters are pre-fired to remove contaminants and acceptance tested. After sampling, filters must be stored in the laboratory in clean, labeled containers under refrigeration (<4 °C) to minimize loss of semi-volatile OC. QA activities include participation in laboratory accreditation programs, external system audits, and interlaboratory comparisons. For thermal/optical carbon analyses, periodic QC tests include calibration of the flame ionization detector with different types of carbon standards, thermogram inspection, replicate analyses, quantification of trace oxygen concentrations (<100 ppmv) in the helium atmosphere, and calibration of the sample temperature sensor. These established QA/QC procedures are applicable to aerosol sampling and analysis for carbon and other chemical components.

  17. Metabologenomics of Phaeochromocytoma and Paraganglioma: An Integrated Approach for Personalised Biochemical and Genetic Testing

    PubMed Central

    Eisenhofer, Graeme; Klink, Barbara; Richter, Susan; Lenders, Jacques WM; Robledo, Mercedes

    2017-01-01

    The tremendous advances over the past two decades in both clinical genetics and biochemical testing of chromaffin cell tumours have led to new considerations about how these aspects of laboratory medicine can be integrated to improve diagnosis and management of affected patients. With germline mutations in 15 genes now identified to be responsible for over a third of all cases of phaeochromocytomas and paragangliomas, these tumours are recognised to have one of the richest hereditary backgrounds among all neoplasms. Depending on the mutation, tumours show distinct differences in metabolic pathways that relate to or even directly impact clinical presentation. At the same time, there has been improved understanding about how catecholamines are synthesised, stored, secreted and metabolised by chromaffin cell tumours. Although the tumours may not always secrete catecholamines it has become clear that almost all continuously produce and metabolise catecholamines. This has not only fuelled changes in laboratory medicine, but has also assisted in recognition of genotype-biochemical phenotype relationships important for diagnostics and clinical care. In particular, differences in catecholamine and energy pathway metabolomes can guide genetic testing, assist with test interpretation and provide predictions about the nature, behaviour and imaging characteristics of the tumours. Conversely, results of genetic testing are important for guiding how routine biochemical testing should be employed and interpreted in surveillance programmes for at-risk patients. In these ways there are emerging needs for modern laboratory medicine to seamlessly integrate biochemical and genetic testing into the diagnosis and management of patients with chromaffin cell tumours. PMID:29332973

  18. Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry in Clinical Microbiology: What Are the Current Issues?

    PubMed Central

    Welker, Martin; Pincus, David; Charrier, Jean-Philippe; Girard, Victoria

    2017-01-01

    Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has revolutionized the identification of microbial species in clinical microbiology laboratories. MALDI-TOF-MS has swiftly become the new gold-standard method owing to its key advantages of simplicity and robustness. However, as with all new methods, adoption of the MALDI-TOF MS approach is still not widespread. Optimal sample preparation has not yet been achieved for several applications, and there are continuing discussions on the need for improved database quality and the inclusion of additional microbial species. New applications such as in the field of antimicrobial susceptibility testing have been proposed but not yet translated to the level of ease and reproducibility that one should expect in routine diagnostic systems. Finally, during routine identification testing, unexpected results are regularly obtained, and the best methods for transmitting these results into clinical care are still evolving. We here discuss the success of MALDI-TOF MS in clinical microbiology and highlight fields of application that are still amenable to improvement. PMID:28840984

  19. Lipemia interferences in routine clinical biochemical tests.

    PubMed

    Calmarza, Pilar; Cordero, José

    2011-01-01

    Lipemic specimens are a common and frequent, but yet unresolved problem in clinical chemistry, and may produce significant interferences in the analytical results of different biochemical parameters. The aim of this study was to examine the effect of lipid removal using ultracentrifugation of lipemic samples, on some routine biochemistry parameters. Among all the samples obtained daily in our laboratory, the ones which were visibly muddy were selected and underwent to a process of ultracentrifugation, being determined a variety of biochemical tests before and after ultracentrifugation. A total of 110 samples were studied. We found significant differences in all the parameters studied except for total bilirubin, glucose, gamma-glutamyl transferase (GGT) and aspartate aminotransferase (AST). The greatest differences in the parameters analyzed were found in the concentration of alanine aminotransferase (ALT) (7.36%) and the smallest ones in the concentration of glucose (0.014%). Clinically significant interferences were found for phosphorus, creatinine, total protein and calcium. Lipemia causes clinically significant interferences for phosphorus, creatinine, total protein and calcium measurement and those interferences could be effectively removed by ultracentrifugation.

  20. Clinical implementation of KRAS testing in metastatic colorectal carcinoma: the pathologist's perspective.

    PubMed

    Ross, Jeffrey S

    2012-10-01

    Mutation status of the KRAS gene identifies a distinct disease subtype of metastatic colorectal carcinoma that does not respond to antibody therapeutics targeting the epidermal growth factor receptor. This is currently the only validated marker in metastatic colorectal carcinoma with a clear implication in treatment selection. KRAS testing is widely accepted in clinical practice to guide metastatic colorectal carcinoma therapeutic decisions, and there are many commercially available platforms to perform the test. To evaluate the critical role of pathologists in the full implementation of KRAS testing by optimizing tumor tissue collection and fixation procedures and by choosing testing technologies and reliable Clinical Laboratory Improvement Amendments of 1988-certified laboratories to perform the tests. Prospective clinical trials, retrospective studies, and quality assessment and survey reports were identified in the following databases: PubMed, American Society of Clinical Oncology Proceedings (American Society of Clinical Oncology Annual Meeting and Gastrointestinal Cancer Symposium) and European Society for Medical Oncology Proceedings (Annals of Oncology European Society for Medical Oncology Congress and Annals of Oncology World Congress on Gastrointestinal Cancers). More bona fide standards are needed to address the variety of available test methods, which have different performance characteristics including speed, sensitivity to detect rare mutations, and technical requirements. Refined standards addressing timing of KRAS testing, laboratory performance and accuracy, quality assurance and control, proper tissue collection, and appropriate result reporting would also be greatly beneficial. Pathologists should be aware that the amount of information they need to manage will increase, because future trends and technological advances will enhance the predictive power of diagnostic tests or the scope of the biomarker panels tested routinely across tumor types.

  1. Pregnancy Outcomes After Maternal Zika Virus Infection During Pregnancy - U.S. Territories, January 1, 2016-April 25, 2017.

    PubMed

    Shapiro-Mendoza, Carrie K; Rice, Marion E; Galang, Romeo R; Fulton, Anna C; VanMaldeghem, Kelley; Prado, Miguel Valencia; Ellis, Esther; Anesi, Magele Scott; Simeone, Regina M; Petersen, Emily E; Ellington, Sascha R; Jones, Abbey M; Williams, Tonya; Reagan-Steiner, Sarah; Perez-Padilla, Janice; Deseda, Carmen C; Beron, Andrew; Tufa, Aifili John; Rosinger, Asher; Roth, Nicole M; Green, Caitlin; Martin, Stacey; Lopez, Camille Delgado; deWilde, Leah; Goodwin, Mary; Pagano, H Pamela; Mai, Cara T; Gould, Carolyn; Zaki, Sherif; Ferrer, Leishla Nieves; Davis, Michelle S; Lathrop, Eva; Polen, Kara; Cragan, Janet D; Reynolds, Megan; Newsome, Kimberly B; Huertas, Mariam Marcano; Bhatangar, Julu; Quiñones, Alma Martinez; Nahabedian, John F; Adams, Laura; Sharp, Tyler M; Hancock, W Thane; Rasmussen, Sonja A; Moore, Cynthia A; Jamieson, Denise J; Munoz-Jordan, Jorge L; Garstang, Helentina; Kambui, Afeke; Masao, Carolee; Honein, Margaret A; Meaney-Delman, Dana

    2017-06-16

    Pregnant women living in or traveling to areas with local mosquito-borne Zika virus transmission are at risk for Zika virus infection, which can lead to severe fetal and infant brain abnormalities and microcephaly (1). In February 2016, CDC recommended 1) routine testing for Zika virus infection of asymptomatic pregnant women living in areas with ongoing local Zika virus transmission at the first prenatal care visit, 2) retesting during the second trimester for women who initially test negative, and 3) testing of pregnant women with signs or symptoms consistent with Zika virus disease (e.g., fever, rash, arthralgia, or conjunctivitis) at any time during pregnancy (2). To collect information about pregnant women with laboratory evidence of recent possible Zika virus infection* and outcomes in their fetuses and infants, CDC established pregnancy and infant registries (3). During January 1, 2016-April 25, 2017, U.S. territories † with local transmission of Zika virus reported 2,549 completed pregnancies § (live births and pregnancy losses at any gestational age) with laboratory evidence of recent possible Zika virus infection; 5% of fetuses or infants resulting from these pregnancies had birth defects potentially associated with Zika virus infection ¶ (4,5). Among completed pregnancies with positive nucleic acid tests confirming Zika infection identified in the first, second, and third trimesters, the percentage of fetuses or infants with possible Zika-associated birth defects was 8%, 5%, and 4%, respectively. Among liveborn infants, 59% had Zika laboratory testing results reported to the pregnancy and infant registries. Identification and follow-up of infants born to women with laboratory evidence of recent possible Zika virus infection during pregnancy permits timely and appropriate clinical intervention services (6).

  2. Influence of centrifuge brake on residual platelet count and routine coagulation tests in citrated plasma.

    PubMed

    Daves, Massimo; Giacomuzzi, Katia; Tagnin, Enrico; Jani, Erika; Adcock Funk, Dorothy M; Favaloro, Emmanuel J; Lippi, Giuseppe

    2014-04-01

    Sample centrifugation is an essential step in the coagulation laboratory, as clotting tests are typically performed on citrated platelet (PLT) poor plasma (PPP). Nevertheless, no clear indication has been provided as to whether centrifugation of specimens should be performed with the centrifuge brake set to on or off. Fifty consecutive sodium citrate anticoagulated samples were collected and divided into two aliquots. The former was centrifuged as for Clinical Laboratory Standards Institute (CLSI) guidelines with the centrifuge brake set to on, whereas the latter was centrifuged again as for CLSI guidelines, but with the brake set to off. In the PPP of all samples, a PLT count was performed, followed by the analysis of activated partial thromboplastin time (APTT), prothrombin time (PT) and fibrinogen (FBG). The PLT count after samples centrifugation was substantially reduced, either with centrifuge brake set to on or off (5 ± 1 versus 3 ± 1 × 10/l; P = 0.009). The frequency of samples exceeding a PLT count less than 10 × 10/l was nearly double in samples centrifuged with the brake on than in those with the brake off (14 versus 8%; P < 0.01). Although no significant difference was found for APTT values, PT was slightly prolonged using the centrifuge brake set to on (mean bias 0.2 s; P < 0.001). FBG values were also significantly higher using the centrifuge brake set to on (mean bias 0.29 g/l; P < 0.001). The results of this study indicate that sample centrifugation for routine coagulation testing should be preferably performed with the centrifuge brake set to off for providing a better quality specimen.

  3. Diagnostic Error of a Patient with Combined Inherited Factor VII and Factor X Deficiency due to Accidental Ingestion of a Diphacinone Rodenticide.

    PubMed

    Li, Min; Jin, Yanhui; Wang, Mingshan; Xie, Yaosheng; Ding, Hongxiang

    2016-11-01

    To explore the characteristics of laboratory examination and confirm the diagnosis of a patient with combined inherited FVII and FX deficiency after he ingested diphacinone rodenticide accidentally. The coagulant parameter screening tests and coagulation factor activities were tested many times in the patient due to accidental ingestion of a diphacinone rodenticide. After the patient was treated for more than one year, gene analysis of correlated coagulation factors was analyzed in the patient and other family members by DNA direct sequencing. 106 persons were selected as controls from routine health examinations. After the patient was admitted to hospital, routine coagulation screening tests revealed the prolonged prothrombin time (PT) and activated partial thromboplastin time (APTT) and low levels of vitamin K-dependent coagulation factors (FII, FVII, FIX, FX) activity, which was 102.4 seconds, 88.5 seconds, 7%, 3%, 8%, and 2%, respectively. During more than one year of treatment, the value of PT and APTT still showed significantly prolonged activity and FVII and FX activity levels were about 5%. While FII and FIX activity levels were in the normal range after 12 weeks of treatment. Two homozygous mutations, g.11267C>T of F7 gene resulting in the substitution Arg277Cys and g.28139G>T of F10 gene leading to the substitution Val384Phe, were identified in the patient. The patient's parents and sister was heterozygous for Arg277Cys and Val384Phe mutations. FVII and FX antigen levels in the patient were 7% and 30%, respectively. There were many similarities in the characteristics of laboratory examination between combined inherited FVII and FX deficiency and acquired vitamin K deficiency. The best way to identify them was gene analysis.

  4. From customer satisfaction survey to corrective actions in laboratory services in a university hospital.

    PubMed

    Oja, Paula I; Kouri, Timo T; Pakarinen, Arto J

    2006-12-01

    To find out the satisfaction of clinical units with laboratory services in a university hospital, to point out the most important problems and defects in services, to carry out corrective actions, and thereafter to identify the possible changes in satisfaction. and Senior physicians and nurses-in-charge of the clinical units at Oulu University Hospital, Finland. Customer satisfaction survey using a questionnaire was carried out in 2001, indicating the essential aspects of laboratory services. Customer-specific problems were clarified, corrective actions were performed, and the survey was repeated in 2004. In 2001, the highest dissatisfaction rates were recorded for computerized test requesting and reporting, turnaround times of tests, and the schedule of phlebotomy rounds. The old laboratory information system was not amenable to major improvements, and it was renewed in 2004-05. Several clinical units perceived turnaround times to be long, because the tests were ordered as routine despite emergency needs. Instructions about stat requesting were given to these units. However, no changes were evident in the satisfaction level in the 2004 survey. Following negotiations with the clinics, phlebotomy rounds were re-scheduled. This resulted in a distinct increase in satisfaction in 2004. Satisfaction survey is a screening tool that identifies topics of dissatisfaction. Without further clarifications, it is not possible to find out the specific problems of customers and to undertake targeted corrective actions. Customer-specific corrections are rarely seen as improvements in overall satisfaction rates.

  5. Reproducibility of up-flow column percolation tests for contaminated soils

    PubMed Central

    Naka, Angelica; Sakanakura, Hirofumi; Kurosawa, Akihiko; Inui, Toru; Takeo, Miyuki; Inoba, Seiji; Watanabe, Yasutaka; Fujikawa, Takuro; Miura, Toshihiko; Miyaguchi, Shinji; Nakajou, Kunihide; Sumikura, Mitsuhiro; Ito, Kenichi; Tamoto, Shuichi; Tatsuhara, Takeshi; Chida, Tomoyuki; Hirata, Kei; Ohori, Ken; Someya, Masayuki; Katoh, Masahiko; Umino, Madoka; Negishi, Masanori; Ito, Keijiro; Kojima, Junichi; Ogawa, Shohei

    2017-01-01

    Up-flow column percolation tests are used at laboratory scale to assess the leaching behavior of hazardous substance from contaminated soils in a specific condition as a function of time. Monitoring the quality of these test results inter or within laboratory is crucial, especially if used for Environment-related legal policy or for routine testing purposes. We tested three different sandy loam type soils (Soils I, II and III) to determine the reproducibility (variability inter laboratory) of test results and to evaluate the difference in the test results within laboratory. Up-flow column percolation tests were performed following the procedure described in the ISO/TS 21268–3. This procedure consists of percolating solution (calcium chloride 1 mM) from bottom to top at a flow rate of 12 mL/h through softly compacted soil contained in a column of 5 cm diameter and 30 ± 5 cm height. Eluate samples were collected at liquid-to-solid ratio of 0.1, 0.2, 0.5, 1, 2, 5 and 10 L/kg and analyzed for quantification of the target elements (Cu, As, Se, Cl, Ca, F, Mg, DOC and B in this research). For Soil I, 17 institutions in Japan joined this validation test. The up-flow column experiments were conducted in duplicate, after 48 h of equilibration time and at a flow rate of 12 mL/h. Column percolation test results from Soils II and III were used to evaluate the difference in test results from the experiments conducted in duplicate in a single laboratory, after 16 h of equilibration time and at a flow rate of 36 mL/h. Overall results showed good reproducibility (expressed in terms of the coefficient of variation, CV, calculated by dividing the standard deviation by the mean), as the CV was lower than 30% in more than 90% of the test results associated with Soil I. Moreover, low variability (expressed in terms of difference between the two test results divided by the mean) was observed in the test results related to Soils II and III, with a variability lower than 30% in more than 88% of the cases for Soil II and in more than 96% of the cases for Soil III. We also discussed the possible factors that affect the reproducibility and variability in the test results from the up-flow column percolation tests. The low variability inter and within laboratory obtained in this research indicates that the ISO/TS 21268–3 can be successfully upgraded to a fully validated ISO standard. PMID:28582458

  6. Clinical chemistry in higher dimensions: Machine-learning and enhanced prediction from routine clinical chemistry data.

    PubMed

    Richardson, Alice; Signor, Ben M; Lidbury, Brett A; Badrick, Tony

    2016-11-01

    Big Data is having an impact on many areas of research, not the least of which is biomedical science. In this review paper, big data and machine learning are defined in terms accessible to the clinical chemistry community. Seven myths associated with machine learning and big data are then presented, with the aim of managing expectation of machine learning amongst clinical chemists. The myths are illustrated with four examples investigating the relationship between biomarkers in liver function tests, enhanced laboratory prediction of hepatitis virus infection, the relationship between bilirubin and white cell count, and the relationship between red cell distribution width and laboratory prediction of anaemia. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Testing for ROS1 in non-small cell lung cancer: a review with recommendations.

    PubMed

    Bubendorf, Lukas; Büttner, Reinhard; Al-Dayel, Fouad; Dietel, Manfred; Elmberger, Göran; Kerr, Keith; López-Ríos, Fernando; Marchetti, Antonio; Öz, Büge; Pauwels, Patrick; Penault-Llorca, Frédérique; Rossi, Giulio; Ryška, Aleš; Thunnissen, Erik

    2016-11-01

    Rearrangements of the ROS1 gene occur in 1-2 % of non-small cell lung cancers (NSCLCs). Crizotinib, a highly effective inhibitor of ROS1 kinase activity, is now FDA-approved for the treatment of patients with advanced ROS1-positive NSCLC. Consequently, focus on ROS1 testing is growing. Most laboratories currently rely on fluorescence in situ hybridisation (FISH) assays using a dual-colour break-apart probe to detect ROS1 rearrangements. Given the rarity of these rearrangements in NSCLC, detection of elevated ROS1 protein levels by immunohistochemistry may provide cost-effective screening prior to confirmatory FISH testing. Non-in situ testing approaches also hold potential as stand-alone methods or complementary tests, including multiplex real-time PCR assays and next-generation sequencing (NGS) platforms which include commercial test kits covering a range of fusion genes. In order to ensure high-quality biomarker testing, appropriate tissue handling, adequate control materials and participation in external quality assessment programmes are essential, irrespective of the testing technique employed. ROS1 testing is often only considered after negative tests for EGFR mutation and ALK gene rearrangement, based on the assumption that these oncogenic driver events tend to be exclusive. However, as the use of ROS1 inhibitors becomes routine, accurate and timely detection of ROS1 gene rearrangements will be critical for the optimal treatment of patients with NSCLC. As NGS techniques are introduced into routine diagnostic practice, ROS1 fusion gene testing will be provided as part of the initial testing package.

  8. Audit of an emergency biochemistry service.

    PubMed Central

    Smellie, W S; Murphy, M J; Galloway, P J; Hinnie, J; McIlroy, J; Dryburgh, F J

    1995-01-01

    AIM--To examine a model for the evaluation of appropriateness of testing in an emergency biochemistry laboratory. METHODS--A model was devised in which incoming emergency test requests were categorised as appropriate or inappropriate. Explicit criteria were used to define eight minor categories, which were chosen to reflect accurately current working practice within the hospital and laboratory. Five junior medical staff each undertook a prospective 24 hour assessment, during which time all incoming requests were monitored and categorised according to these criteria. Concordance between monitors was evaluated before and during assessments. RESULTS--Of 509 requests, 384 (75%) were appropriate and 125 (25%) were inappropriate according to the criteria used to define categories. Inappropriate requests fell into three main groups: preoperative samples (43.2% (54/125) of all inappropriate requests), missed routine samples (33.6% (42/125)) and accelerated (priority) analyses (16% (20/125)). Various other reasons accounted for the remaining 7.2% (9/125). CONCLUSION--This model may be used to obtain valid information about current clinical and laboratory practice. Strategies to reduce the number of inappropriate requests have been identified in order to reserve the emergency service for situations of true need. PMID:8568000

  9. Adult encephalitis surveillance: experiences from an Australian prospective sentinel site study.

    PubMed

    Eastwood, K; Paterson, B J; Levi, C; Givney, R; Loewenthal, M; DE Malmanche, T; Lai, K; Granerod, J; Durrheim, D N

    2015-11-01

    Few countries routinely collect comprehensive encephalitis data, yet understanding the epidemiology of this condition has value for clinical management, detecting novel and emerging pathogens, and guiding timely public health interventions. When this study was conducted there was no standardized diagnostic algorithm to aid identification of encephalitis or systematic surveillance for adult encephalitis. In July 2012 we tested three pragmatic surveillance options aimed at identifying possible adult encephalitis cases admitted to a major Australian hospital: hospital admissions searches, clinician notifications and laboratory test alerts (CSF herpes simplex virus requests). Eligible cases underwent structured laboratory investigation and a specialist panel arbitrated on the final diagnosis. One hundred and thirteen patients were initially recruited into the 10-month study; 20/113 (18%) met the study case definition, seven were diagnosed with infectious or immune-mediated encephalitis and the remainder were assigned alternative diagnoses. The laboratory alert identified 90% (102/113) of recruited cases including six of the seven cases of confirmed encephalitis suggesting that this may be a practical data source for case ascertainment. The application of a standardized diagnostic algorithm and specialist review by an expert clinical panel aided diagnosis of patients with encephalitis.

  10. Sputum color: potential implications for clinical practice.

    PubMed

    Johnson, Allen L; Hampson, David F; Hampson, Neil B

    2008-04-01

    Respiratory infections with sputum production are a major reason for physician visits, diagnostic testing, and antibiotic prescription in the United States. We sought to determine whether the simple characteristic of sputum color provides information that impacts resource utilization such as laboratory testing and prescription of antibiotics. Out-patient sputum samples submitted to the microbiology laboratory for routine analysis were assigned to one of 8 color categories (green, yellow-green, rust, yellow, red, cream, white, and clear), based on a key made from paint chip color samples. Subsequent Gram stain and culture results were compared to sputum color. Of 289 consecutive samples, 144 (50%) met standard Gram-stain criteria for being acceptable lower-respiratory-tract specimens. In the acceptable Gram-stain group, 60 samples had a predominant organism on Gram stain, and the culture yielded a consistent result in 42 samples (15% of the 289 total specimens). Yield at each level of analysis differed greatly by color. The yield from sputum colors green, yellow-green, yellow, and rust was much higher than the yield from cream, white, or clear. If out-patient sputum is cream, white, or clear, the yield from bacteriologic analysis is extremely low. This information can reduce laboratory processing costs and help minimize unnecessary antibiotic prescription.

  11. Implementing a laboratory automation system: experience of a large clinical laboratory.

    PubMed

    Lam, Choong Weng; Jacob, Edward

    2012-02-01

    Laboratories today face increasing pressure to automate their operations as they are challenged by a continuing increase in workload, need to reduce expenditure, and difficulties in recruitment of experienced technical staff. Was the implementation of a laboratory automation system (LAS) in the Clinical Biochemistry Laboratory at Singapore General Hospital successful? There is no simple answer, so the following topics comparing and contrasting pre- and post-LAS have been explored: turnaround time (TAT), laboratory errors, and staff satisfaction. The benefits and limitations of LAS from the laboratory experience were also reviewed. The mean TAT for both stat and routine samples decreased post-LAS (30% and 13.4%, respectively). In the 90th percentile TAT chart, a 29% reduction was seen in the processing of stat samples on the LAS. However, no significant difference in the 90th percentile TAT was observed with routine samples. It was surprising to note that laboratory errors increased post-LAS. Considerable effort was needed to overcome the initial difficulties associated with adjusting to a new system, new software, and new working procedures. Although some of the known advantages and limitations of LAS have been validated, the claimed benefits such as improvements in TAT, laboratory errors, and staff morale were not evident in the initial months.

  12. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry, a revolution in clinical microbial identification.

    PubMed

    Bizzini, A; Greub, G

    2010-11-01

    Until recently, matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for the identification of microorganisms remained confined to research laboratories. In the last 2 years, the availability of relatively simple to use MALDI-TOF MS devices, which can be utilized in clinical microbiology laboratories, has changed the laboratory workflows for the identification of pathogens. Recently, the first prospective studies regarding the performance in routine bacterial identification showed that MALDI-TOF MS is a fast, reliable and cost-effective technique that has the potential to replace and/or complement conventional phenotypic identification for most bacterial strains isolated in clinical microbiology laboratories. For routine bacterial isolates, correct identification by MALDI-TOF MS at the species level was obtained in 84.1-93.6% of instances. In one of these studies, a protein extraction step clearly improved the overall valid identification yield, from 70.3% to 93.2%. This review focuses on the current state of use of MALDI-TOF MS for the identification of routine bacterial isolates and on the main difficulties that may lead to erroneous or doubtful identifications. © 2010 The Authors. Clinical Microbiology and Infection © 2010 European Society of Clinical Microbiology and Infectious Diseases.

  13. Clinical application of high throughput molecular screening techniques for pharmacogenomics

    PubMed Central

    Wiita, Arun P; Schrijver, Iris

    2011-01-01

    Genetic analysis is one of the fastest-growing areas of clinical diagnostics. Fortunately, as our knowledge of clinically relevant genetic variants rapidly expands, so does our ability to detect these variants in patient samples. Increasing demand for genetic information may necessitate the use of high throughput diagnostic methods as part of clinically validated testing. Here we provide a general overview of our current and near-future abilities to perform large-scale genetic testing in the clinical laboratory. First we review in detail molecular methods used for high throughput mutation detection, including techniques able to monitor thousands of genetic variants for a single patient or to genotype a single genetic variant for thousands of patients simultaneously. These methods are analyzed in the context of pharmacogenomic testing in the clinical laboratories, with a focus on tests that are currently validated as well as those that hold strong promise for widespread clinical application in the near future. We further discuss the unique economic and clinical challenges posed by pharmacogenomic markers. Our ability to detect genetic variants frequently outstrips our ability to accurately interpret them in a clinical context, carrying implications both for test development and introduction into patient management algorithms. These complexities must be taken into account prior to the introduction of any pharmacogenomic biomarker into routine clinical testing. PMID:23226057

  14. Lyssaviruses: special emphasis on rabies virus and other members of the lyssavirus genus.

    PubMed

    Harkess, Graeme; Fooks, Anthony R

    2011-01-01

    Rabies is routinely diagnosed based on the clinical description and history of exposure in a rabies-endemic country. A negative diagnostic test for rabies virus or a related lyssavirus does not exclude the clinical diagnosis. Diagnostic tests are never optimal and are entirely dependent on the nature and quality of the sample supplied. Often, only a sample from a single time point is investigated reducing the overall sensitivity of any diagnosis. With the advent of molecular biology, tests have been developed that are rapid, robust, and sensitive in support of the rapid detection and strain identification of rabies virus from clinical specimens. These molecular tests complement conventional tests in rabies diagnosis, particularly for human cases, for which an early laboratory diagnosis is critical and may decrease the number of unnecessary contacts with the patient, reduce the requirement for invasive and costly interventions, and enable the appropriate medical treatment regimen to be administered for the patient. The barrier to success is in transferring the technology for the latest techniques in rabies diagnosis to rabies-endemic countries. These barriers are not insurmountable and in liaison with international organisations, especially OIE, FAO, and WHO, these diagnostic tests will be validated for rabies diagnosis and surveillance, and implemented in modern and well-equipped diagnostic laboratories throughout the world.

  15. Prospective and retrospective evaluation of the Cepheid Xpert® Flu/RSV XC assay for rapid detection of influenza A, influenza B, and respiratory syncytial virus.

    PubMed

    Salez, Nicolas; Nougairede, Antoine; Ninove, Laetitia; Zandotti, Christine; de Lamballerie, Xavier; Charrel, Remi N

    2015-04-01

    A total of 281 clinical specimens (nasal swabs and nasopharyngeal aspirates) were tested with the Xpert® Flu/RSV XC. The results were compared to those obtained with the real-time retro transcriptase-polymerase chain reaction assays routinely used in our laboratory. The Xpert® Flu/RSV XC showed sensitivity/specificity of 97.8%/100% and 97.9%/100% for flu and respiratory syncytial virus, respectively. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Performance and cost analysis of matrix-assisted laser desorption ionization-time of flight mass spectrometry for routine identification of yeast.

    PubMed

    Dhiman, Neelam; Hall, Leslie; Wohlfiel, Sherri L; Buckwalter, Seanne P; Wengenack, Nancy L

    2011-04-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry was compared to phenotypic testing for yeast identification. MALDI-TOF mass spectrometry yielded 96.3% and 84.5% accurate species level identifications (spectral scores, ≥ 1.8) for 138 common and 103 archived strains of yeast. MALDI-TOF mass spectrometry is accurate, rapid (5.1 min of hands-on time/identification), and cost-effective ($0.50/sample) for yeast identification in the clinical laboratory.

  17. Quality management system in the CIEMAT Radiation Dosimetry Service.

    PubMed

    Martín, R; Navarro, T; Romero, A M; López, M A

    2011-03-01

    This paper describes the activities realised by the CIEMAT Radiation Dosimetry Service (SDR) for the implementation of a quality management system (QMS) in order to achieve compliance with the requirements of ISO/IEC 17025 and to apply for the accreditation for testing measurements of radiation dose. SDR has decided the accreditation of the service as a whole and not for each of its component laboratories. This makes it necessary to design a QMS common to all, thus ensuring alignment and compliance with standard requirements, and simplifying routine works as possible.

  18. Discordant Umbilical Cord Drug Testing Results in Monozygotic Twins.

    PubMed

    Alexander, Amy; Abbas, Liaqat; Jones, Mary; Jones, Joseph; Lewis, Douglas; Negrusz, Adam

    2018-06-01

    Our laboratory received segments of umbilical cord that originated from identical twins for routine toxicology analysis. The specimens were analyzed multiple times by liquid chromatography tandem mass spectrometry. The umbilical cord from newborn #1 was positive for hydromorphone only (1.06 ng/g), and the umbilical cord from newborn #2 was positive for hydromorphone (0.81 ng/g) and benzoylecgonine (5.41 ng/g). The hydromorphone results are consistent with maternal administration of hydromorphone; however, the cause of the discrepant benzoylecgonine results in the umbilical cords from the identical twins is unknown.

  19. Incidence of Fusarium moniliforme Sheld. in Zea mays L. in the rainforest zone of Nigeria.

    PubMed

    Iloba, C

    1979-01-01

    45 seed samples from 7 states of the rainforest zone of Nigeria (Ogun, Ondo, Oyo, Bendel, Anambra, Imo, and Cross River) were screened for phytopathogen incidence. Whereas Drechslera maydis was found in 30 and Cephalosporium maydis in 79% of the samples were infected by Fusarium moniliforme, with 70% of the samples showing heavy infection. In view of the widespread nature of this economically important fungus on maize in the main cultivation area of Nigeria, the necessity for routine laboratory seed health tests is clearly indicated.

  20. Classification of anemia for gastroenterologists

    PubMed Central

    Moreno Chulilla, Jose Antonio; Romero Colás, Maria Soledad; Gutiérrez Martín, Martín

    2009-01-01

    Most anemia is related to the digestive system by dietary deficiency, malabsorption, or chronic bleeding. We review the World Health Organization definition of anemia, its morphological classification (microcytic, macrocytic and normocytic) and pathogenic classification (regenerative and hypo regenerative), and integration of these classifications. Interpretation of laboratory tests is included, from the simplest (blood count, routine biochemistry) to the more specific (iron metabolism, vitamin B12, folic acid, reticulocytes, erythropoietin, bone marrow examination and Schilling test). In the text and various algorithms, we propose a hierarchical and logical way to reach a diagnosis as quickly as possible, by properly managing the medical interview, physical examination, appropriate laboratory tests, bone marrow examination, and other complementary tests. The prevalence is emphasized in all sections so that the gastroenterologist can direct the diagnosis to the most common diseases, although the tables also include rare diseases. Digestive diseases potentially causing anemia have been studied in preference, but other causes of anemia have been included in the text and tables. Primitive hematological diseases that cause anemia are only listed, but are not discussed in depth. The last section is dedicated to simplifying all items discussed above, using practical rules to guide diagnosis and medical care with the greatest economy of resources and time. PMID:19787825

  1. Testing-adjusted chlamydia notification trends in New South Wales, Australia, 2000 to 2010.

    PubMed

    Cretikos, Michelle; Mayne, Darren; Reynolds, Roderick; Spokes, Paula; Madeddu, Daniel

    2014-01-01

    Between 2005 and 2010, Australian notification rates for chlamydia infection increased by 64% from 203 to 333 per 100 000 population. Interpreting this trend is difficult without examining rates and local patterns of testing. We examined the effect of adjusting for local testing rates on chlamydia notification trends in New South Wales (NSW), Australia from 2000 to 2010. We used testing data for NSW residents for Medicare Benefits Schedule items for chlamydia from 1 July 1999 to 30 June 2005 and 1 July 2007 to 30 June 2010. This data set excluded testing by public sector laboratories. We also obtained laboratory-confirmed genital chlamydia notifications in NSW residents for 1 July 1999 to 30 June 2010 and excluded notifications from public laboratories. We used negative binomial regression to assess trends in chlamydia notification rates by age and sex after adjusting for local government area (LGA)-level Medicare-funded testing rates, socioeconomic disadvantage, remoteness and Medicare provider density. Testing-adjusted rates of chlamydia notifications declined by 5.2% per annum (rate ratio [RR] = 0.95, 95% confidence interval (CI) = 0.93-0.96) for women overall, and 2.3% (RR = 0.98, 95% CI = 0.96-1.00) and 5.0% per annum (RR = 0.95, 95% CI = 0.93-0.98) for men in LGAs with moderate and high densities of Medicare providers, respectively. Notification rates remained stable for men in low Medicare provider density LGAs (RR = 1.01, 95% CI = 0.96-1.07). It is likely that increased testing for chlamydia has driven increases in chlamydia notification in NSW over the last decade. Notification data provide no evidence for a general increase in the prevalence of chlamydia in the NSW community for this period. Notification-based chlamydia surveillance should be routinely adjusted for local testing rates.

  2. Auto Emission Testing

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The photos show automobile engines being tested for nitrous oxide emissions, as required by the Environmental Protection Agency (EPA), at the Research and Engineering Division of Ford Motor Company, Dearborn. Michigan. NASA technical information helped the company develop a means of calculating emissions test results. Nitrous oxide emission readings vary with relative humidity in the test facility. EPA uses a standard humidity measurement, but the agency allows manufacturers to test under different humidity conditions, then apply a correction factor to adjust the results to the EPA standard. NASA's Dryden Flight Research Center developed analytic equations which provide a simple, computer-programmable method of correcting for humidity variations. A Ford engineer read a NASA Tech Brief describing the Dryden development and requested more detailed information in the form of a technical support package, which NASA routinely supplies to industry on request. Ford's Emissions Test Laboratory now uses the Dryden equations for humidity-adjusted emissions data reported to EPA.

  3. Impact of point-of-care implementation of Xpert® MTB/RIF: product vs. process innovation.

    PubMed

    Schumacher, S G; Thangakunam, B; Denkinger, C M; Oliver, A A; Shakti, K B; Qin, Z Z; Michael, J S; Luo, R; Pai, M; Christopher, D J

    2015-09-01

    Both product innovation (e.g., more sensitive tests) and process innovation (e.g., a point-of-care [POC] testing programme) could improve patient outcomes. To study the respective contributions of product and process innovation in improving patient outcomes. We implemented a POC programme using Xpert(®) MTB/RIF in an out-patient clinic of a tertiary care hospital in India. We measured the impact of process innovation by comparing time to diagnosis with routine testing vs. POC testing. We measured the impact of product innovation by comparing accuracy and time to diagnosis using smear microscopy vs. POC Xpert. We enrolled 1012 patients over a 15-month period. Xpert had high accuracy, but the incremental value of one Xpert over two smears was only 6% (95%CI 3-12). Implementing Xpert as a routine laboratory test did not reduce the time to diagnosis compared to smear-based diagnosis. In contrast, the POC programme reduced the time to diagnosis by 5.5 days (95%CI 4.3-6.7), but required dedicated staff and substantial adaptation of clinic workflow. Process innovation by way of a POC Xpert programme had a greater impact on time to diagnosis than the product per se, and can yield important improvements in patient care that are complementary to those achieved by introducing innovative technologies.

  4. Association of serologic and hematologic test results in dengue infant patients in RSUP. Dr. Hasan Sadikin Bandung

    NASA Astrophysics Data System (ADS)

    Alam, A.; Handayani, I.; Indrati, A. R.

    2018-03-01

    The incidence of Dengue virus infection is increasing every year,and the progression of the disease is faster towards severe manifestations in infants than in children and adults.The clinical appearance is still challenging to make for the diagnosis of dengue fever, so routine blood examination becomes one of thefurther enforcement efforts. The gold standard isconfirmatory tests for dengue, but this examination would be difficult in remote areas and also cost more. Research on serological testing and its association with routine blood testing in infant dengue-infected patients is still less publicized. The purpose of this study was to describe theconnection between serological and routine blood test results of infant dengue infection patients in RSUP Dr. Hasan Sadikin. Observational design in dengue 56 infants with 2-12 months age range examined serologic test and routine blood examination. The results showed that serological testing tended to be on routine blood tests. It can be from differences in routine blood tests such as hemoglobin, hematocrit, and platelets. Also, there was also no difference in routine blood profile between reactive and non-reactive IgM groups. It suggests that routine blood examination results are still lacking for the diagnosis of dengue.

  5. In-laboratory development of an automatic track counting system for solid state nuclear track detectors

    NASA Astrophysics Data System (ADS)

    Uzun, Sefa Kemal; Demiröz, Işık; Ulus, İzzet

    2017-01-01

    In this study, an automatic track counting system was developed for solid state nuclear track detectors (SSNTD). Firstly the specifications of required hardware components were determined, and accordingly the CCD camera, microscope and stage motor table was supplied and integrated. The system was completed by developing parametric software with VB.Net language. Finally a set of test intended for radon activity concentration measurement was applied. According to the test results, the system was enabled for routine radon measurement. Whether the parameters of system are adjusted for another SSNTD application, it could be used for other fields of SSNTD like neutron dosimetry or heavy charged particle detection.

  6. GMOseek: a user friendly tool for optimized GMO testing.

    PubMed

    Morisset, Dany; Novak, Petra Kralj; Zupanič, Darko; Gruden, Kristina; Lavrač, Nada; Žel, Jana

    2014-08-01

    With the increasing pace of new Genetically Modified Organisms (GMOs) authorized or in pipeline for commercialization worldwide, the task of the laboratories in charge to test the compliance of food, feed or seed samples with their relevant regulations became difficult and costly. Many of them have already adopted the so called "matrix approach" to rationalize the resources and efforts used to increase their efficiency within a limited budget. Most of the time, the "matrix approach" is implemented using limited information and some proprietary (if any) computational tool to efficiently use the available data. The developed GMOseek software is designed to support decision making in all the phases of routine GMO laboratory testing, including the interpretation of wet-lab results. The tool makes use of a tabulated matrix of GM events and their genetic elements, of the laboratory analysis history and the available information about the sample at hand. The tool uses an optimization approach to suggest the most suited screening assays for the given sample. The practical GMOseek user interface allows the user to customize the search for a cost-efficient combination of screening assays to be employed on a given sample. It further guides the user to select appropriate analyses to determine the presence of individual GM events in the analyzed sample, and it helps taking a final decision regarding the GMO composition in the sample. GMOseek can also be used to evaluate new, previously unused GMO screening targets and to estimate the profitability of developing new GMO screening methods. The presented freely available software tool offers the GMO testing laboratories the possibility to select combinations of assays (e.g. quantitative real-time PCR tests) needed for their task, by allowing the expert to express his/her preferences in terms of multiplexing and cost. The utility of GMOseek is exemplified by analyzing selected food, feed and seed samples from a national reference laboratory for GMO testing and by comparing its performance to existing tools which use the matrix approach. GMOseek proves superior when tested on real samples in terms of GMO coverage and cost efficiency of its screening strategies, including its capacity of simple interpretation of the testing results.

  7. Microplates in liquid chromatography--new solution in clinical research? A review.

    PubMed

    Krcmova, Lenka; Solichova, Dagmar; Solich, Petr

    2013-10-15

    Microplates are routinely used in Radio- or Immuno-assays. Recently, microplates have found use not only in analytical but also in the pre-analytical phase in bioanalyses (sample storage, sample preparation). New connection of this technology to liquid chromatography could be economical, fast and simple solution for many routine laboratories handling large sequences of biological samples. This review summarises the application of microplates in bioanalytical laboratories. Different types of sorbents, materials and shapes of microplates are discussed, and the main advantages and disadvantages of microplates used in clinical research are presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. What Makes Me Screen for HIV? Perceived Barriers and Facilitators to Conducting Recommended Routine HIV Testing among Primary care Physicians in the Southeastern United States

    PubMed Central

    White, Becky L.; Walsh, Joan; Rayasam, Swati; Pathman, Donald E.; Adimora, Adaora A.; Golin, Carol E.

    2015-01-01

    The Centers for Disease Control and Prevention have recommended routinely testing patients (aged 13–64) for HIV since 2006. However, many physicians do not routinely test. From January 2011- March 2012, we conducted 18 in-depth individual interviews and explored primary care physicians’ perceptions of barriers and facilitators to implementing routine HIV testing in North Carolina. Physicians’ comments were categorized thematically and fell into five groups: policy, community, practice, physician and patient. Lack of universal reimbursement was identified as the major policy barrier. Participants believed endorsement from the United States Preventive Services Tasks Force would facilitate adoption of routine HIV testing policies. Physicians reported HIV/AIDS stigma, socially conservative communities, lack of confidentiality, and rural geography as community barriers. Physicians believed public HIV testing campaigns would legitimize testing and decrease stigma in communities. Physicians cited time constraints and competing clinical priorities as physician barriers that could be overcome by delegating testing to nursing staff. HIV test refusal, low HIV risk perception, and stigma emerged as patient barriers. Physicians recommended adoption of routine HIV testing for all patients to facilitate and destigmatize testing. Physicians continue to experience a variety of barriers when implementing routine HIV testing in primary care settings. Our findings support multilevel approaches to enhance physician routine HIV testing in primary care settings. PMID:24643412

  9. Evaluation of airborne asbestos exposure from routine handling of asbestos-containing wire gauze pads in the research laboratory.

    PubMed

    Garcia, Ediberto; Newfang, Daniel; Coyle, Jayme P; Blake, Charles L; Spencer, John W; Burrelli, Leonard G; Johnson, Giffe T; Harbison, Raymond D

    2018-07-01

    Three independently conducted asbestos exposure evaluations were conducted using wire gauze pads similar to standard practice in the laboratory setting. All testing occurred in a controlled atmosphere inside an enclosed chamber simulating a laboratory setting. Separate teams consisting of a laboratory technician, or technician and assistant simulated common tasks involving wire gauze pads, including heating and direct wire gauze manipulation. Area and personal air samples were collected and evaluated for asbestos consistent with the National Institute of Occupational Safety Health method 7400 and 7402, and the Asbestos Hazard Emergency Response Act (AHERA) method. Bulk gauze pad samples were analyzed by Polarized Light Microscopy and Transmission Electron Microscopy to determine asbestos content. Among air samples, chrysotile asbestos was the only fiber found in the first and third experiments, and tremolite asbestos for the second experiment. None of the air samples contained asbestos in concentrations above the current permissible regulatory levels promulgated by OSHA. These findings indicate that the level of asbestos exposure when working with wire gauze pads in the laboratory setting is much lower than levels associated with asbestosis or asbestos-related lung cancer and mesothelioma. Copyright © 2018. Published by Elsevier Inc.

  10. Estimated Prevalence of Cryptococcus Antigenemia (CrAg) among HIV-Infected Adults with Advanced Immunosuppression in Namibia Justifies Routine Screening and Preemptive Treatment.

    PubMed

    Sawadogo, Souleymane; Makumbi, Boniface; Purfield, Anne; Ndjavera, Christophine; Mutandi, Gram; Maher, Andrew; Kaindjee-Tjituka, Francina; Kaplan, Jonathan E; Park, Benjamin J; Lowrance, David W

    2016-01-01

    Cryptococcal meningitis is common and associated with high mortality among HIV infected persons. The World Health Organization recommends that routine Cryptococcal antigen (CrAg) screening in ART-naïve adults with a CD4+ count <100 cells/μL followed by pre-emptive antifungal therapy for CrAg-positive patients be considered where CrAg prevalence is ≥3%. The prevalence of CrAg among HIV adults in Namibia is unknown. We estimated CrAg prevalence among HIV-infected adults receiving care in Namibia for the purpose of informing routine screening strategies. The study design was cross-sectional. De-identified plasma specimens collected for routine CD4+ testing from HIV-infected adults enrolled in HIV care at 181 public health facilities from November 2013 to January 2014 were identified at the national reference laboratory. Remnant plasma from specimens with CD4+ counts <200 cells/μL were sampled and tested for CrAg using the IMMY® Lateral Flow Assay. CrAg prevalence was estimated and assessed for associations with age, sex, and CD4+ count. A total of 825 specimens were tested for CrAg. The median (IQR) age of patients from whom specimens were collected was 38 (32-46) years, 45.9% were female and 62.9% of the specimens had CD4 <100 cells/μL. CrAg prevalence was 3.3% overall and 3.9% and 2.3% among samples with CD4+ counts of CD4+<100 cells/μL and 100-200 cells/μL, respectively. CrAg positivity was significantly higher among patients with CD4+ cells/μL < 50 (7.2%, P = 0.001) relative to those with CD4 cells/μL 50-200 (2.2%). This is the first study to estimate CrAg prevalence among HIV-infected patients in Namibia. CrAg prevalence of ≥3.0% among patients with CD4+<100 cells/μL justifies routine CrAg screening and preemptive treatment among HIV-infected in Namibia in line with WHO recommendations. Patients with CD4+<100 cells/μL have a significantly greater risk for CrAg positivity. Revised guidelines for ART in Namibia now recommend routine screening for CrAg.

  11. An update on the use of cerebrospinal fluid analysis as a diagnostic tool in multiple sclerosis.

    PubMed

    Gastaldi, Matteo; Zardini, Elisabetta; Franciotta, Diego

    2017-01-01

    Intrathecal B-lymphocyte activation is a hallmark of multiple sclerosis (MS), a multi-factorial inflammatory-demyelinating disease of the central nervous system. Such activation has a counterpart in the cerebrospinal fluid (CSF) oligoclonal IgG bands (OCB), whose diagnostic role in MS has been downgraded within the current McDonald's criteria. With a theoretico-practical approach, the authors review the physiopathological basis of the CSF dynamics, and the state-of-the-art of routine CSF analysis and CSF biomarkers in MS. Areas covered: The authors discuss pros and cons of CSF analysis, including critical evaluations of both well-established, and promising diagnostic and prognostic laboratory tools. New acquisitions on the CSF and cerebral interstitial fluid dynamics are also presented. The authors searched the PubMed database for English-language articles reported between January 2010 and June 2016, using the key words 'multiple sclerosis', 'cerebrospinal fluid', 'oligoclonal bands'. Reference lists of relevant articles were scanned for additional studies. Expert commentary: The availability of performing high-quality, routine CSF tests in specialized laboratories, the emerging potential of novel CSF biomarkers, and the trend for early treatments should induce a reappraisal of CSF analysis for diagnostic and prognostic purposes in MS. Further procedural and methodological improvements seem to be necessary in both research and translational diagnostic CSF settings.

  12. A note from history: Landmarks in history of cancer, part 7.

    PubMed

    Hajdu, Steven I; Vadmal, Manjunath; Tang, Ping

    2015-08-01

    In the 2 and half decades reviewed (1970-1995), research established that chromosomal translocation, deletion, and DNA amplification are prerequisites to cancerogenesis and that oncogenes, tumor-suppressor genes, growth factors, and cytokines play crucial roles in the pathomechanism of cancer. Human papillomavirus, human immunodeficiency virus, herpes virus, and hepatitis B virus were identified as cancer-causing viruses. Several laboratory tests were developed for the detection of primary and recurrent cancers, and cancer prevention by screening methods was popularized. Sonography, computerized tomography, magnetic resonance imaging, positron emission tomography, excision of sentinel lymph nodes, and immunohistochemical techniques became routine procedures. Clinicopathologic staging and classification of tumors were standardized. Limited surgery, adjuvant and neoadjuvant chemoradiation, and the therapeutic use of monoclonal antibodies, tumor vaccines, and targeted chemotherapy became routine practice. The decline in cancer incidence and mortality demonstrated that cancer prevention and advancement in oncology are pivotal to success in the crusade against cancer. Above all, it was clearly established that the care of patients with cancer can be accomplished best in a multidisciplinary setting involving surgical oncologists, radiologists, radiation therapists, medical oncologists, surgical pathologists, and laboratory scientists. In conclusion, the 25 years from 1970 and 1995 are the high-water mark in clinical oncology, and this is the period when oncology turned from art to science. © 2015 American Cancer Society.

  13. Higher Expression of Toll-like Receptors 3, 7, 8, and 9 in Pityriasis Rosea.

    PubMed

    El-Ela, Mostafa Abou; El-Komy, Mohamed; Hay, Rania Abdel; Hegazy, Rehab; Sharobim, Amin; Rashed, Laila; Amr, Khalda

    2017-03-01

    Pityriasis rosea (PR) is a common papulosquamous skin disease in which an infective agent may be implicated. Toll-like receptors (TLRs) play an important role in immune responses and in the pathophysiology of inflammatory skin diseases. Our aim was to determine the possible roles of TLRs 3, 7, 8, and 9 in the pathogenesis of PR. Twenty-four PR patients and 24 healthy individuals (as controls) were included in this case control study. All recruits were subjected to routine laboratory investigations. Biopsies were obtained from one active PR lesion and from healthy skin of controls for the detection of TLR 3, 7, 8, and 9 gene expression using real-time polymerase chain reaction. This study included 24 patients (8 females and 16 males) with active PR lesions, with a mean age of 28.62 years. Twenty four healthy age- and sex-matched individuals were included as controls (8 females and 16 males, with a mean age of 30.83 years). The results of the routine laboratory tests revealed no significant differences between both groups. Significantly elevated expression of all studied TLRs were detected in PR patients relative to healthy controls (p < .001). TLRs 3, 7, 8, and 9 might be involved in the pathogenesis of PR.

  14. Higher Expression of Toll-like Receptors 3, 7, 8, and 9 in Pityriasis Rosea

    PubMed Central

    El-Ela, Mostafa Abou; El-Komy, Mohamed; Hay, Rania Abdel; Hegazy, Rehab; Sharobim, Amin; Rashed, Laila; Amr, Khalda

    2017-01-01

    Background Pityriasis rosea (PR) is a common papulosquamous skin disease in which an infective agent may be implicated. Toll-like receptors (TLRs) play an important role in immune responses and in the pathophysiology of inflammatory skin diseases. Our aim was to determine the possible roles of TLRs 3, 7, 8, and 9 in the pathogenesis of PR. Methods Twenty-four PR patients and 24 healthy individuals (as controls) were included in this case control study. All recruits were subjected to routine laboratory investigations. Biopsies were obtained from one active PR lesion and from healthy skin of controls for the detection of TLR 3, 7, 8, and 9 gene expression using real-time polymerase chain reaction. Results This study included 24 patients (8 females and 16 males) with active PR lesions, with a mean age of 28.62 years. Twenty four healthy age- and sex-matched individuals were included as controls (8 females and 16 males, with a mean age of 30.83 years). The results of the routine laboratory tests revealed no significant differences between both groups. Significantly elevated expression of all studied TLRs were detected in PR patients relative to healthy controls (p < .001). Conclusions TLRs 3, 7, 8, and 9 might be involved in the pathogenesis of PR. PMID:28192646

  15. Mass Spectrometry in Clinical Laboratory: Applications in Therapeutic Drug Monitoring and Toxicology.

    PubMed

    Garg, Uttam; Zhang, Yan Victoria

    2016-01-01

    Mass spectrometry (MS) has been used in research and specialized clinical laboratories for decades as a very powerful technology to identify and quantify compounds. In recent years, application of MS in routine clinical laboratories has increased significantly. This is mainly due to the ability of MS to provide very specific identification, high sensitivity, and simultaneous analysis of multiple analytes (>100). The coupling of tandem mass spectrometry with gas chromatography (GC) or liquid chromatography (LC) has enabled the rapid expansion of this technology. While applications of MS are used in many clinical areas, therapeutic drug monitoring, drugs of abuse, and clinical toxicology are still the primary focuses of the field. It is not uncommon to see mass spectrometry being used in routine clinical practices for those applications.

  16. Radiation and Health Technology Laboratory Capabilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bihl, Donald E.; Lynch, Timothy P.; Murphy, Mark K.

    2005-07-09

    The Radiological Standards and Calibrations Laboratory, a part of Pacific Northwest National Laboratory (PNNL)(a) performs calibrations and upholds reference standards necessary to maintain traceability to national standards. The facility supports U.S. Department of Energy (DOE) programs at the Hanford Site, programs sponsored by DOE Headquarters and other federal agencies, radiological protection programs at other DOE and commercial nuclear sites and research and characterization programs sponsored through the commercial sector. The laboratory is located in the 318 Building of the Hanford Site's 300 Area. The facility contains five major exposure rooms and several laboratories used for exposure work preparation, low-activity instrumentmore » calibrations, instrument performance evaluations, instrument maintenance, instrument design and fabrication work, thermoluminescent and radiochromic Dosimetry, and calibration of measurement and test equipment (M&TE). The major exposure facilities are a low-scatter room used for neutron and photon exposures, a source well room used for high-volume instrument calibration work, an x-ray facility used for energy response studies, a high-exposure facility used for high-rate photon calibration work, a beta standards laboratory used for beta energy response studies and beta reference calibrations and M&TE laboratories. Calibrations are routinely performed for personnel dosimeters, health physics instrumentation, photon and neutron transfer standards alpha, beta, and gamma field sources used throughout the Hanford Site, and a wide variety of M&TE. This report describes the standards and calibrations laboratory.« less

  17. Reporting unit size and measurement uncertainty: current Australian practice in clinical chemistry and haematology.

    PubMed

    Hawkins, Robert C; Badrick, Tony

    2015-08-01

    In this study we aimed to compare the reporting unit size used by Australian laboratories for routine chemistry and haematology tests to the unit size used by learned authorities and in standard laboratory textbooks and to the justified unit size based on measurement uncertainty (MU) estimates from quality assurance program data. MU was determined from Royal College of Pathologists of Australasia (RCPA) - Australasian Association of Clinical Biochemists (AACB) and RCPA Haematology Quality Assurance Program survey reports. The reporting unit size implicitly suggested in authoritative textbooks, the RCPA Manual, and the General Serum Chemistry program itself was noted. We also used published data on Australian laboratory practices.The best performing laboratories could justify their chemistry unit size for 55% of analytes while comparable figures for the 50% and 90% laboratories were 14% and 8%, respectively. Reporting unit size was justifiable for all laboratories for red cell count, >50% for haemoglobin but only the top 10% for haematocrit. Few, if any, could justify their mean cell volume (MCV) and mean cell haemoglobin concentration (MCHC) reporting unit sizes.The reporting unit size used by many laboratories is not justified by present analytical performance. Using MU estimates to determine the reporting interval for quantitative laboratory results ensures reporting practices match local analytical performance and recognises the inherent error of the measurement process.

  18. The effectiveness of computer-generated 3D animations in inquiry chemistry laboratory

    NASA Astrophysics Data System (ADS)

    Theall, Rachel Morgan

    It has been shown that students need a molecular-level understanding of substances in order to comprehend chemistry. For solid structures, atomic-level understanding requires students to learn additional and different concepts than for other states of matter. To aid understanding, animations were created to model unit cell structures and depict the properties of unit cells. In order to determine if these animations are helpful to students, they were tested during a laboratory exercise in which students had previously been using model kits and images from textbooks to learn about solid structures. Students evaluated in this study were from two lecture sections of general chemistry, one that routinely used animations during lecture and one that used a more traditional lecture format that did not include animations or models. Twelve laboratory sections of these lectures, taught by six different instructors each teaching two sections, were chosen for participation. One section for each instructor was given the animations as an optional tool for completing the laboratory assignment, which consisted of questions about unit cells and crystal structures. The results of the study indicate that students who looked at the animations performed significantly better on the assignment. For the control group, students who routinely viewed multiple representations of chemistry in lecture performed significantly better on the lab assignment than students in the lecture section where chemistry concepts were only presented on the chalkboard and overhead projector. Students in the traditional lecture section also had significantly less appreciation for the model kits used in the laboratory than students in the other lecture section. Observations of students in the lab combined with statistical results led to the revision of the solid structures investigation. Additional animations were created and inserted into the module that covered areas where students indicated more help was needed. Movies of "real life" chemistry were also incorporated into the module to help students relate the investigation to prior knowledge.

  19. Correlation between serological and immunofluorescence results in the investigation of brucellosis in veterinary surgeons.

    PubMed Central

    Henderson, R J; Hill, D M; Vickers, A A; Edwards, J M; Tillett, H

    1976-01-01

    Four serological tests and three immunofluorescence tests for IgG, IgM, and IgA were compared for value in the investigation of brucellosis in veterinary surgeons. No one serological test stood out over the others, and the immunofluorescence tests did not appear to have advantages over the serological tests. If a laboratory is limited in time and resources then the saline agglutination or the complement fixation test would be reasonably satisfactory. The 2-mercaptoethanol test and the antihuman globulin (Coombs' test) have no advantages over the other two and could be dropped. Immunofluorescence tests are not recommended for routine testing of brucellosis sera. The results and these recommendations apply to the 'vet' sera tested; it is reasonable to suppose that what applies to 'vet' sera will also apply to sera of those who work with or are in repeated contact with cattle and who will have had previous experience of brucella antigen, that is, dairy farmers, herdsmen, or slaughter house employees. PMID:765361

  20. Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories.

    PubMed

    Wallin, Olof; Söderberg, Johan; Van Guelpen, Bethany; Stenlund, Hans; Grankvist, Kjell; Brulin, Christine

    2010-09-01

    Scand J Caring Sci; 2010; 24; 581-591 
 Blood sample collection and patient identification demand improvement: a questionnaire study of preanalytical practices in hospital wards and laboratories   Most errors in venous blood testing result from human mistakes occurring before the sample reach the laboratory.   To survey venous blood sampling (VBS) practices in hospital wards and to compare practices with hospital laboratories.   Staff in two hospitals (all wards) and two hospital laboratories (314 respondents, response rate 94%), completed a questionnaire addressing issues relevant to the collection of venous blood samples for clinical chemistry testing.   The findings suggest that instructions for patient identification and the collection of venous blood samples were not always followed. For example, 79% of the respondents reported the undesirable practice (UDP) of not always using wristbands for patient identification. Similarly, 87% of the respondents noted the UDP of removing venous stasis after the sampling is finished. Compared with the ward staff, a significantly higher proportion of the laboratory staff reported desirable practices regarding the collection of venous blood samples. Neither education nor the existence of established sampling routines was clearly associated with VBS practices among the ward staff.   The results of this study, the first of its kind, suggest that a clinically important risk of error is associated with VBS in the surveyed wards. Most important is the risk of misidentification of patients. Quality improvement of blood sample collection is clearly needed, particularly in hospital wards. © 2009 The Authors. Journal compilation © 2009 Nordic College of Caring Science.

  1. The Expectations of Teachers and Students Who Visit a Non-Formal Student Chemistry Laboratory

    ERIC Educational Resources Information Center

    Garner, Nicole; Eilks, Ingo

    2015-01-01

    Non-formal student laboratory environments for primary and secondary school science education have become a major trend in the German educational arena in recent years. These non-formal student laboratory environments are thought to offer unique experimental learning experiences that often cannot be realized in daily school routines. The biggest…

  2. Prejudice, segregation and immigration laws —integration of the robot into the laboratory society

    PubMed Central

    Fraley, Jr., Norman E.

    1994-01-01

    This paper addresses some serious issues about personnel morale, fears and hopes associated with and attributed to the laboratory robot. The introduction of the laboratory robot into the laboratory is examined from a managerial perspective. Human-rights and robot-rights issues are identified and addressed. Real world examples of how the integration of two high through-put robots affected the routine of a major industrial food laboratory are discussed. PMID:18925001

  3. A rigorous approach to facilitate and guarantee the correctness of the genetic testing management in human genome information systems.

    PubMed

    Araújo, Luciano V; Malkowski, Simon; Braghetto, Kelly R; Passos-Bueno, Maria R; Zatz, Mayana; Pu, Calton; Ferreira, João E

    2011-12-22

    Recent medical and biological technology advances have stimulated the development of new testing systems that have been providing huge, varied amounts of molecular and clinical data. Growing data volumes pose significant challenges for information processing systems in research centers. Additionally, the routines of genomics laboratory are typically characterized by high parallelism in testing and constant procedure changes. This paper describes a formal approach to address this challenge through the implementation of a genetic testing management system applied to human genome laboratory. We introduced the Human Genome Research Center Information System (CEGH) in Brazil, a system that is able to support constant changes in human genome testing and can provide patients updated results based on the most recent and validated genetic knowledge. Our approach uses a common repository for process planning to ensure reusability, specification, instantiation, monitoring, and execution of processes, which are defined using a relational database and rigorous control flow specifications based on process algebra (ACP). The main difference between our approach and related works is that we were able to join two important aspects: 1) process scalability achieved through relational database implementation, and 2) correctness of processes using process algebra. Furthermore, the software allows end users to define genetic testing without requiring any knowledge about business process notation or process algebra. This paper presents the CEGH information system that is a Laboratory Information Management System (LIMS) based on a formal framework to support genetic testing management for Mendelian disorder studies. We have proved the feasibility and showed usability benefits of a rigorous approach that is able to specify, validate, and perform genetic testing using easy end user interfaces.

  4. A rigorous approach to facilitate and guarantee the correctness of the genetic testing management in human genome information systems

    PubMed Central

    2011-01-01

    Background Recent medical and biological technology advances have stimulated the development of new testing systems that have been providing huge, varied amounts of molecular and clinical data. Growing data volumes pose significant challenges for information processing systems in research centers. Additionally, the routines of genomics laboratory are typically characterized by high parallelism in testing and constant procedure changes. Results This paper describes a formal approach to address this challenge through the implementation of a genetic testing management system applied to human genome laboratory. We introduced the Human Genome Research Center Information System (CEGH) in Brazil, a system that is able to support constant changes in human genome testing and can provide patients updated results based on the most recent and validated genetic knowledge. Our approach uses a common repository for process planning to ensure reusability, specification, instantiation, monitoring, and execution of processes, which are defined using a relational database and rigorous control flow specifications based on process algebra (ACP). The main difference between our approach and related works is that we were able to join two important aspects: 1) process scalability achieved through relational database implementation, and 2) correctness of processes using process algebra. Furthermore, the software allows end users to define genetic testing without requiring any knowledge about business process notation or process algebra. Conclusions This paper presents the CEGH information system that is a Laboratory Information Management System (LIMS) based on a formal framework to support genetic testing management for Mendelian disorder studies. We have proved the feasibility and showed usability benefits of a rigorous approach that is able to specify, validate, and perform genetic testing using easy end user interfaces. PMID:22369688

  5. Failure analysis of a tool steel torque shaft

    NASA Technical Reports Server (NTRS)

    Reagan, J. R.

    1981-01-01

    A low design load drive shaft used to deliver power from an experimental exhaust heat recovery system to the crankshaft of an experimental diesel truck engine failed during highway testing. An independent testing laboratory analyzed the failure by routine metallography and attributed the failure to fatigue induced by a banded microstructure. Visual examination by NASA of the failed shaft plus the knowledge of the torsional load that it carried pointed to a 100 percent ductile failure with no evidence of fatigue. Scanning electron microscopy confirmed this. Torsional test specimens were produced from pieces of the failed shaft and torsional overload testing produced identical failures to that which had occurred in the truck engine. This pointed to a failure caused by a high overload and although the microstructure was defective it was not the cause of the failure.

  6. Remediation of Manufactured Methamphetamine in Clandestine Laboratories. A Literature Review

    EPA Science Inventory

    The purpose of the current literature review was to identify, collect, review, and organize all available information concerning the remediation of methamphetamine found in clandestine laboratories through an analysis of routinely collected data sources. There were numerous peer ...

  7. Calf antibiotic and sulfonamide test (CAST) for screening antibiotic and sulfonamide residues in calf carcasses.

    PubMed

    Dey, Bhabani P; Reamer, Richard P; Thaker, Nitin H; Thaler, Alice M

    2005-01-01

    The Calf Antibiotic and Sulfonamide Test (CAST), a microbial inhibition screening test, was developed for detecting antibiotics and sulfonamides in bob veal calf carcasses. The test uses Bacillus megaterium ATCC 9885 as the indicator organism and Mueller Hinton agar as the growth medium. Compared to Swab Test on Premises (STOP), developed in 1970, this screening test has higher sensitivity and the ability to detect a wider range of veterinary antimicrobial residual drugs, particularly sulfonamides, at lower concentrations. Carcasses that are tested with CAST and suspected of containing chemical residue above tolerance level are retained for confirmation. Disposition of these carcasses are determined upon laboratory result. Routine testing of bob veal calves with CAST allowed the Food Safety and Inspection Service to release most calf carcasses within 24 h post-slaughter, thus conserving shipping and handling resources. However, changes in the regulation in 1990 dictate that disposition of carcasses found to contain violative levels of sulfonamide residues should be based on laboratory findings. The analysis of the data for the years 1990-1994 and 1998 indicate that the use of CAST over the years was significant, and had a direct impact on reduction of residue violations in veal carcasses. With the use of CAST, potentially harmful antimicrobial chemicals entering the human food chain through veal meat have been minimized.

  8. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    PubMed

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  9. Comparison of the MUREX C. albicans, Albicans-Sure, and BactiCard Candida test kits with the germ tube test for presumptive identification of Candida albicans.

    PubMed Central

    Crist, A E; Dietz, T J; Kampschroer, K

    1996-01-01

    The MUREX C. albicans (MC)(Murex Diagnostics), Albicans-Sure (AS) (Clinical Standards Laboratories), and BactiCard Candida (BC) (Remel) test kits were compared with the germ tube (GT) test for the rapid, presumptive identification of Candida albicans. All three test kits detect the enzymes L-proline aminopeptidase and beta-galactosaminidase in yeast cells grown on culture media and are based on the principle that C. albicans produces both enzymes whereas other yeasts produce only one or neither of the enzymes. The organisms evaluated were fresh clinical isolates identified by methods routinely used in our laboratory (API 20C system and conventional methods) and included 303 C. albicans isolates, 153 Candida glabrata isolates, 70 Candida tropicalis isolates, 36 Candida parapsilosis isolates, 13 isolates of other Candida spp., 5 Cryptococcus neoformans isolates, and 3 Saccharomyces cerevisiae isolates. The MC, AS, BC, and GT tests detected 299 (98.7%), 300 (99.0%), 301 (99.3%), and 287 (94.7%) C. albicans isolates, respectively. There was one false-positive result with both the MC and BC kits and two false-positive results with the GT test. The enzymatic methods evaluated in this study provide rapid and accurate alternatives to the GT test for the presumptive identification of C. albicans. PMID:8880535

  10. Rapid, comprehensive, and affordable mycobacterial diagnosis with whole-genome sequencing: a prospective study

    PubMed Central

    Pankhurst, Louise J; del Ojo Elias, Carlos; Votintseva, Antonina A; Walker, Timothy M; Cole, Kevin; Davies, Jim; Fermont, Jilles M; Gascoyne-Binzi, Deborah M; Kohl, Thomas A; Kong, Clare; Lemaitre, Nadine; Niemann, Stefan; Paul, John; Rogers, Thomas R; Roycroft, Emma; Smith, E Grace; Supply, Philip; Tang, Patrick; Wilcox, Mark H; Wordsworth, Sarah; Wyllie, David; Xu, Li; Crook, Derrick W

    2016-01-01

    Summary Background Slow and cumbersome laboratory diagnostics for Mycobacterium tuberculosis complex (MTBC) risk delayed treatment and poor patient outcomes. Whole-genome sequencing (WGS) could potentially provide a rapid and comprehensive diagnostic solution. In this prospective study, we compare real-time WGS with routine MTBC diagnostic workflows. Methods We compared sequencing mycobacteria from all newly positive liquid cultures with routine laboratory diagnostic workflows across eight laboratories in Europe and North America for diagnostic accuracy, processing times, and cost between Sept 6, 2013, and April 14, 2014. We sequenced specimens once using local Illumina MiSeq platforms and processed data centrally using a semi-automated bioinformatics pipeline. We identified species or complex using gene presence or absence, predicted drug susceptibilities from resistance-conferring mutations identified from reference-mapped MTBC genomes, and calculated genetic distance to previously sequenced UK MTBC isolates to detect outbreaks. WGS data processing and analysis was done by staff masked to routine reference laboratory and clinical results. We also did a microcosting analysis to assess the financial viability of WGS-based diagnostics. Findings Compared with routine results, WGS predicted species with 93% (95% CI 90–96; 322 of 345 specimens; 356 mycobacteria specimens submitted) accuracy and drug susceptibility also with 93% (91–95; 628 of 672 specimens; 168 MTBC specimens identified) accuracy, with one sequencing attempt. WGS linked 15 (16% [95% CI 10–26]) of 91 UK patients to an outbreak. WGS diagnosed a case of multidrug-resistant tuberculosis before routine diagnosis was completed and discovered a new multidrug-resistant tuberculosis cluster. Full WGS diagnostics could be generated in a median of 9 days (IQR 6–10), a median of 21 days (IQR 14–32) faster than final reference laboratory reports were produced (median of 31 days [IQR 21–44]), at a cost of £481 per culture-positive specimen, whereas routine diagnosis costs £518, equating to a WGS-based diagnosis cost that is 7% cheaper annually than are present diagnostic workflows. Interpretation We have shown that WGS has a scalable, rapid turnaround, and is a financially feasible method for full MTBC diagnostics. Continued improvements to mycobacterial processing, bioinformatics, and analysis will improve the accuracy, speed, and scope of WGS-based diagnosis. Funding National Institute for Health Research, Department of Health, Wellcome Trust, British Colombia Centre for Disease Control Foundation for Population and Public Health, Department of Clinical Microbiology, Trinity College Dublin. PMID:26669893

  11. Cell cloning-on-the-spot by using an attachable silicone cylinder.

    PubMed

    Park, Hong Bum; Son, Wonseok; Chae, Dong Han; Lee, Jisu; Kim, Il-Woung; Yang, Woomi; Sung, Jae Kyu; Lim, Kyu; Lee, Jun Hee; Kim, Kyung-Hee; Park, Jong-Il

    2016-06-10

    Cell cloning is a laboratory routine to isolate and keep particular properties of cultured cells. Transfected or other genetically modified cells can be selected by the traditional microbiological cloning. In addition, common laboratory cell lines are prone to genotypic drift during their continual culture, so that supplementary cloning steps are often required to maintain correct lineage phenotypes. Here, we designed a silicone-made attachable cloning cylinder, which facilitated an easy and bona fide cloning of interested cells. This silicone cylinder was easy to make, showed competent stickiness to laboratory plastics including culture dishes, and hence enabled secure isolation and culture for days of selected single cells, especially, on the spots of preceding cell-plating dishes under microscopic examination of visible cellular phenotypes. We tested the silicone cylinder in the monoclonal subcloning from a heterogeneous population of a breast cancer cell line, MDA-MB-231, and readily established independent MDA-MB-231 subclones showing different sublineage phenotypes. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Lesser known aspects of Ludwik Fleck's (1896-1961) heroic life during World War II.

    PubMed

    Grzybowski, Andrzej; Ciesielska, Maria

    2016-08-01

    Professor Ludwik Fleck was a famous scientist and a prominent philosopher. Although his life and work were studied extensively, the Second World War period was a subject of some discussion and controversy. On account of his Jewish origin, he was first arrested and moved from the Lwów ghetto to the 'Laokoon' factory and then imprisoned in KL Auschwitz-Birkenau and in KL Buchenwald. Fleck produced the anti-typhus vaccine in the chemo-bacteriological laboratory in the Jewish Hospital at Kuszewicza Street and in the 'Laokoon' factory in Lwów. During his incarceration in KL Auschwitz-Birkenau, Fleck worked in the camp laboratory in Block 10 carrying out bacteriological studies for the inmates and then was assigned to work in the Wasserman station in Rajsko. From January 1944 Fleck performed routine laboratory tests in Block 50 in KL Buchenwald. Though Fleck had a privileged life in the camp, he participated in the sabotage activities organized by the camp resistance. © The Author(s) 2016.

  13. Reagent Strips as an Aid to Diagnosis of Neonatal Meningitis in a Resource-limited Setting.

    PubMed

    Burgoine, Kathy; Ikiror, Juliet; Naizuli, Ketty; Achom, Linda; Akol, Sylivia; Olupot-Olupot, Peter

    2018-01-29

    Without early recognition and treatment, neonatal meningitis (NM) has a high mortality and morbidity. Although some neonates have features of NM, many do not. In many low-resource settings, the laboratory support to diagnose NM is not available, and bedside diagnostics are needed. This retrospective study was conducted in a neonatal unit in Uganda. Clear cerebrospinal fluid samples were routinely screened for glucose, protein and leukocytes on a Combur®-10 urinalysis reagent strip. A definitive diagnosis was made using laboratory analysis. The results of the screening and definitive tests were compared. The reagent strip showed moderate sensitivity and high specificity for leukocytes ≥10×106 cells/l, high sensitivity for protein ≥100 mg/dl and high specificity for glucose <50 mg/dl. The use of reagent strips has the potential to improve and hasten the diagnosis of probable NM in settings where adequate or timely laboratory support is not available. © The Author(s) [2018]. Published by Oxford University Press.

  14. Current strategies to avoid misdiagnosis of malaria.

    PubMed

    Hänscheid, T

    2003-06-01

    Malaria remains the most important parasitic disease, and tens of thousands of cases are imported into non-endemic countries annually. However, any single institution may see only a very few cases-this is probably the reason why laboratory and clinical misdiagnosis may not be uncommon. In the laboratory, unfamiliarity with microscopic diagnosis may be the main reason, considering the large number of laboratory staff who provide on-call services, often without expert help at hand, as well as the difficulty in detecting cases with low-level parasitemia. Staff should therefore be provided with continuing microscopic training to maintain proficiency. The complementary use of immunochromatographic rapid detection tests (RDTs) may be useful, especially during on-call hours, although, in order to ensure correct interpretation, their inherent limitations have to be well known. Diagnosis based on the polymerase chain reaction is still unsuitable for routine use, due to its long turnaround time, its cost, and its unavailability outside regular hours, although it may be helpful in selected cases. Once the alert clinician has considered the possibility of malaria, and suspicion continues to be high, malaria can be excluded by repeat smears or RDTs. However, the absence of clinical suspicion may not be infrequent, and may have more serious consequences. Depending on the local number of malaria cases seen, laboratory staff should have a low threshold for the decision to perform unsolicited malaria diagnostic tests on suspicious samples, especially if other laboratory tests are abnormal (e.g. thrombocytopenia, presence of atypical lymphocytes, or raised lactate dehydrogenase). The detection of intraleukocytic hemozoin during automated full blood counts is a promising new way to avoid misdiagnosis of clinically unsuspected malaria.

  15. Comparative Validation of Five Quantitative Rapid Test Kits for the Analysis of Salt Iodine Content: Laboratory Performance, User- and Field-Friendliness

    PubMed Central

    Rohner, Fabian; Kangambèga, Marcelline O.; Khan, Noor; Kargougou, Robert; Garnier, Denis; Sanou, Ibrahima; Ouaro, Bertine D.; Petry, Nicolai; Wirth, James P.; Jooste, Pieter

    2015-01-01

    Background Iodine deficiency has important health and development consequences and the introduction of iodized salt as national programs has been a great public health success in the past decades. To render national salt iodization programs sustainable and ensure adequate iodization levels, simple methods to quantitatively assess whether salt is adequately iodized are required. Several methods claim to be simple and reliable, and are available on the market or are in development. Objective This work has validated the currently available quantitative rapid test kits (quantRTK) in a comparative manner for both their laboratory performance and ease of use in field settings. Methods Laboratory performance parameters (linearity, detection and quantification limit, intra- and inter-assay imprecision) were conducted on 5 quantRTK. We assessed inter-operator imprecision using salt of different quality along with the comparison of 59 salt samples from across the globe; measurements were made both in a laboratory and a field setting by technicians and non-technicians. Results from the quantRTK were compared against iodometric titration for validity. An ‘ease-of-use’ rating system was developed to identify the most suitable quantRTK for a given task. Results Most of the devices showed acceptable laboratory performance, but for some of the devices, use by non-technicians revealed poorer performance when working in a routine manner. Of the quantRTK tested, the iCheck® and I-Reader® showed most consistent performance and ease of use, and a newly developed paper-based method (saltPAD) holds promise if further developed. Conclusions User- and field-friendly devices are now available and the most appropriate quantRTK can be selected depending on the number of samples and the budget available. PMID:26401655

  16. A Follow-Up of the Multicenter Collaborative Study on HIV-1 Drug Resistance and Tropism Testing Using 454 Ultra Deep Pyrosequencing

    PubMed Central

    St. John, Elizabeth P.; Simen, Birgitte B.; Turenchalk, Gregory S.; Braverman, Michael S.; Abbate, Isabella; Aerssens, Jeroen; Bouchez, Olivier; Gabriel, Christian; Izopet, Jacques; Meixenberger, Karolin; Di Giallonardo, Francesca; Schlapbach, Ralph; Paredes, Roger; Sakwa, James; Schmitz-Agheguian, Gudrun G.; Thielen, Alexander; Victor, Martin

    2016-01-01

    Background Ultra deep sequencing is of increasing use not only in research but also in diagnostics. For implementation of ultra deep sequencing assays in clinical laboratories for routine diagnostics, intra- and inter-laboratory testing are of the utmost importance. Methods A multicenter study was conducted to validate an updated assay design for 454 Life Sciences’ GS FLX Titanium system targeting protease/reverse transcriptase (RTP) and env (V3) regions to identify HIV-1 drug-resistance mutations and determine co-receptor use with high sensitivity. The study included 30 HIV-1 subtype B and 6 subtype non-B samples with viral titers (VT) of 3,940–447,400 copies/mL, two dilution series (52,129–1,340 and 25,130–734 copies/mL), and triplicate samples. Amplicons spanning PR codons 10–99, RT codons 1–251 and the entire V3 region were generated using barcoded primers. Analysis was performed using the GS Amplicon Variant Analyzer and geno2pheno for tropism. For comparison, population sequencing was performed using the ViroSeq HIV-1 genotyping system. Results The median sequencing depth across the 11 sites was 1,829 reads per position for RTP (IQR 592–3,488) and 2,410 for V3 (IQR 786–3,695). 10 preselected drug resistant variants were measured across sites and showed high inter-laboratory correlation across all sites with data (P<0.001). The triplicate samples of a plasmid mixture confirmed the high inter-laboratory consistency (mean% ± stdev: 4.6 ±0.5, 4.8 ±0.4, 4.9 ±0.3) and revealed good intra-laboratory consistency (mean% range ± stdev range: 4.2–5.2 ± 0.04–0.65). In the two dilutions series, no variants >20% were missed, variants 2–10% were detected at most sites (even at low VT), and variants 1–2% were detected by some sites. All mutations detected by population sequencing were also detected by UDS. Conclusions This assay design results in an accurate and reproducible approach to analyze HIV-1 mutant spectra, even at variant frequencies well below those routinely detectable by population sequencing. PMID:26756901

  17. Results from Testing of Two Rotary Percussive Drilling Systems

    NASA Technical Reports Server (NTRS)

    Kriechbaum, Kristopher; Brown, Kyle; Cady, Ian; von der Heydt, Max; Klein, Kerry; Kulczycki, Eric; Okon, Avi

    2010-01-01

    The developmental test program for the MSL (Mars Science Laboratory) rotary percussive drill examined the e ect of various drill input parameters on the drill pene- tration rate. Some of the input parameters tested were drill angle with respect to gravity and percussive impact energy. The suite of rocks tested ranged from a high strength basalt to soft Kaolinite clay. We developed a hole start routine to reduce high sideloads from bit walk. The ongoing development test program for the IMSAH (Integrated Mars Sample Acquisition and Handling) rotary percussive corer uses many of the same rocks as the MSL suite. An additional performance parameter is core integrity. The MSL development test drill and the IMSAH test drill use similar hardware to provide rotation and percussion. However, the MSL test drill uses external stabilizers, while the IMSAH test drill does not have external stabilization. In addition the IMSAH drill is a core drill, while the MSL drill uses a solid powdering bit. Results from the testing of these two related drilling systems is examined.

  18. Use of WGS in Mycobacterium tuberculosis routine diagnosis.

    PubMed

    Cirillo, Daniela M; Cabibbe, Andrea M; De Filippo, Maria Rosaria; Trovato, Alberto; Simonetti, Tullia; Rossolini, Gian Maria; Tortoli, Enrico

    2016-12-01

    Whole Genome Sequencing (WGS) is becoming affordable with overall costs comparable to other tests currently in use to perform the diagnosis of drug-resistant tuberculosis (TB) and cluster analysis. The WGS approach allows an "all-in-one" approach providing results on expected sensitivity of the strains, genetic background, epidemiological data, and indication of risk of laboratory cross-contamination. Although ideal, WGS from the direct diagnostic specimen is not yet standardized, and to date the two most promising approaches are WGS from early positive liquid culture and targeted sequencing from diagnostic specimens using Next-Generation Technology. Both have advantages and disadvantages. Sequencing from early MGIT requires positive cultures, whereas targeted sequencing can be performed from a specimen positive for Mycobacterium tuberculosis with a consistent gain in time to information. The aim of this study is to evaluate the feasibility and cost of using WGS with a centralized approach to speed up diagnosis of TB in a low-incidence country. From March 2016 to September 2016, we collected and processed by WGS 89 early positive routine MGIT960 tubes. Time to diagnosis and accuracy of this technique were compared with those of standard testing performed in a regular laboratory. A 2-mL aliquot of early positive MGIT was processed, starting with heat inactivation. DNA was then isolated by using the Maxwell 16 Cell DNA Purification Kit and Maxwell 16 MDx for automated extraction. Paired-end libraries of read-length 75-151bp were prepared using the Nextera XT DNA Sample Preparation kit, and sequenced on Illumina Miseq/Miniseq platform (based on the 1st available run). Total variant calling was performed according to the pipeline of the Phyresse web-tool. The DNA isolation step required 30min for inactivation plus 30min for extraction. The concentration obtained ranged from 0.1 to 1ng/μL, suitable for library preparation. Samples were sequenced with a turnaround time of 24-48h. The percentage of reads mapped to the H37Rv reference genome was 83% on average. The mean read coverage was 65×. The main challenge was the presence of nonmycobacterial DNA contamination in a variable amount. Lineage detection was possible for all cases, and mutations associated with drug resistance to antitubercular drugs were examined. We observed high diagnostic accuracy for species identification and detection of full drug resistance profile compared to standard DST testing performed in MGIT. Two events of recent transmissions including respectively three and two patients were identified, and two laboratory cross-contaminations were investigated and confirmed based on the analysis. Time to availability of report was about 72h from MGIT positivity compared to up to 6-9weeks for XDR-TB diagnosis with standard testing. In addition to speed, the main advantages were the availability of a full prediction of resistance determinants for rifampicin-resistant cases, and the fast detection of potential cross-contaminations and clusters to guide epidemiological investigation and cross-border tracing. Cost analysis showed that the cost per strain was approximately €150 inclusive of staff cost, reagents, and machine cost. WGS is a rapid, cost-effective technique that promises to integrate and replace the other tests in routine laboratories for an accurate diagnosis of DR-TB, although it is suitable nowadays for cultured samples only. Copyright © 2016.

  19. Investigating CSI: portrayals of DNA testing on a forensic crime show and their potential effects.

    PubMed

    Ley, Barbara L; Jankowski, Natalie; Brewer, Paul R

    2012-01-01

    The popularity of forensic crime shows such as CSI has fueled debate about their potential social impact. This study considers CSI's potential effects on public understandings regarding DNA testing in the context of judicial processes, the policy debates surrounding crime laboratory procedures, and the forensic science profession, as well as an effect not discussed in previous accounts: namely, the show's potential impact on public understandings of DNA and genetics more generally. To develop a theoretical foundation for research on the "CSI effect," it draws on cultivation theory, social cognitive theory, and audience reception studies. It then uses content analysis and textual analysis to illuminate how the show depicts DNA testing. The results demonstrate that CSI tends to depict DNA testing as routine, swift, useful, and reliable and that it echoes broader discourses about genetics. At times, however, the show suggests more complex ways of thinking about DNA testing and genetics.

  20. Laboratory aspects of tick-borne diseases: lyme, human granulocytic ehrlichiosis and babesiosis.

    PubMed

    Aguero-Rosenfeld, Marie E

    2003-05-01

    Lyme disease, human granulocytic ehrlichiosis (HGE) and babesiosis are emerging infections in the northeastern and midwestern United States, where Ixodes scapularis ticks are prevalent. Lyme disease and babesiosis have also been reported on the West Coast, but less frequently. Lyme disease presents frequently with a skin lesion known as erythema migrans (EM), and diagnostic tests are not necessary if the lesion is classical. Those patients presenting without EM or with atypical skin lesions may need laboratory confirmation. The most frequently used laboratory modality consists of the 2-step serological assays, employing a sensitive ELISA as a first step, followed by IgG and/or IgM immunoblots. Current guidelines for interpretation are those recommended by the CDC. HGE and babesiosis are febrile illnesses with non-specific signs and symptoms. Both infections may present with routine laboratory abnormalities, including leukopenia and/or thrombocytopenia in HGE and anemia in babesiosis. Moderate elevations of liver enzymes may occur in all three tick-borne infections. Specific diagnostic modalities for acute-phase HGE include buffy coat smear examination, culture and PCR. Culture appears to have the greatest sensitivity of the three tests. Babesiosis can be diagnosed by peripheral blood examination for the intraerythrocytic parasites, PCR or serology. Co-infections with these agents exist, but they should be documented by detection of the organisms rather than by serology, since seroprevalence rates are high in endemic areas.

  1. Purpura, cutaneous necrosis, and antineutrophil cytoplasmic antibodies associated with levamisole-adulterated cocaine.

    PubMed

    Graf, Jonathan; Lynch, Kara; Yeh, Chia-Lin; Tarter, Laura; Richman, Nicole; Nguyen, Thuy; Kral, Alex; Dominy, Steven; Imboden, John

    2011-12-01

    To describe the clinical and serologic abnormalities in 6 patients who presented with retiform purpura and extensive cutaneous necrosis after exposure to levamisole-adulterated cocaine. All patients were evaluated at San Francisco General Hospital or the University of California San Francisco Medical Center. Each underwent standard screening for substances of abuse and had urine tested for the presence of levamisole by liquid chromatography tandem mass spectrometry. Routine laboratory, autoantibody, and antiphospholipid antibody testing was performed in the hospitals' clinical or reference laboratories. Testing for atypical antineutrophil cytoplasmic antibodies (ANCAs) was performed separately using commercially available enzyme-linked immunosorbent assay kits. The patients were women ages 39-50 years who presented with retiform purpura and cutaneous necrosis. Skin biopsies revealed a predominantly small-vessel thrombotic vasculopathy with varying degrees of vasculitis. Four patients were neutropenic. All tested positive for lupus anticoagulant, had IgM antibodies to cardiolipin, and tested strongly positive for ANCAs in a perinuclear pattern by immunofluorescence. Each patient had antibodies to multiple components of neutrophil granules, including neutrophil elastase, lactoferrin, cathepsin G, proteinase 3, and myeloperoxidase. Rheumatologists should be aware of this distinctive form of necrotic purpura, its associated autoantibodies, and its link to levamisole-adulterated cocaine. Copyright © 2011 by the American College of Rheumatology.

  2. Serological Diagnosis of Paracoccidioidomycosis: High Rate of Inter-laboratorial Variability among Medical Mycology Reference Centers

    PubMed Central

    Vidal, Monica Scarpelli Martinelli; Del Negro, Gilda Maria Barbaro; Vicentini, Adriana Pardini; Svidzinski, Teresinha Inez Estivalet; Mendes-Giannini, Maria Jose; Almeida, Ana Marisa Fusco; Martinez, Roberto; de Camargo, Zoilo Pires; Taborda, Carlos Pelleschi; Benard, Gil

    2014-01-01

    Background Serological tests have long been established as rapid, simple and inexpensive tools for the diagnosis and follow-up of PCM. However, different protocols and antigen preparations are used and the few attempts to standardize the routine serological methods have not succeeded. Methodology/Principal findings We compared the performance of six Brazilian reference centers for serological diagnosis of PCM. Each center provided 30 sera of PCM patients, with positive high, intermediate and low titers, which were defined as the “reference” titers. Each center then applied its own antigen preparation and serological routine test, either semiquantitative double immunodifusion or counterimmmunoelectrophoresis, in the 150 sera from the other five centers blindly as regard to the “reference” titers. Titers were transformed into scores: 0 (negative), 1 (healing titers), 2 (active disease, low titers) and 3 (active disease, high titers) according to each center's criteria. Major discordances were considered between scores indicating active disease and scores indicating negative or healing titers; such discordance when associated with proper clinical and other laboratorial data, may correspond to different approaches to the patient's treatment. Surprisingly, all centers exhibited a high rate of “major” discordances with a mean of 31 (20%) discordant scores. Alternatively, when the scores given by one center to their own sera were compared with the scores given to their sera by the remaining five other centers, a high rate of major discordances was also found, with a mean number of 14.8 sera in 30 presenting a discordance with at least one other center. The data also suggest that centers that used CIE and pool of isolates for antigen preparation performed better. Conclusion There are inconsistencies among the laboratories that are strong enough to result in conflicting information regarding the patients' treatment. Renewed efforts should be promoted to improve standardization of the serological diagnosis of PCM. PMID:25211336

  3. Evaluation of paper gradient concentration strips for antifungal combination testing of Candida spp.

    PubMed

    Siopi, Maria; Siafakas, Nikolaos; Zerva, Loukia; Meletiadis, Joseph

    2015-11-01

    In vitro combination testing with broth microdilution chequerboard (CHEQ) method is widely used although it is time-consuming, cumbersome and difficult to apply in routine setting of clinical microbiology laboratory. A new gradient concentration paper strip method, the Liofilchem(®) MIC test strips (MTS), provides an alternative easy and fast method enabling the simultaneous diffusion of both drugs in combination. We therefore tested a polyene+azole and an azole+echinocandin combination against 18 Candida isolates with the CHEQ method based on EUCAST guidelines and the MTS method in research and routine settings. Fractional inhibitory concentration (FIC) indices were calculated after 24 and 48 h of incubation based on complete and prominent (FIC-2) growth inhibition endpoints. Reproducibility and agreement within 1 twofold dilution was assessed. The FICs of the two methods were correlated quantitatively with t-test and Pearson analysis and qualitatively with Chi-squared test. The reproducibility of the CHEQ and MTS method was 88-100% and their agreement was 80% with 62-77% of MTS FICs being higher than the corresponding CHEQ FICs. A statistically significant Pearson correlation (r = 0.86, P = 0.0003) and association (χ(2) = 17.05, df = 4, P = 0.002) was found between MTS FIC and CHEQ FIC-2 after 24 h. Categorical agreement was 63% with no very major or major errors. All MTS synergistic interactions were also synergistic with the CHEQ method. © 2015 Blackwell Verlag GmbH.

  4. Implementation of TPMT testing

    PubMed Central

    Lennard, Lynne

    2014-01-01

    The activity of the enzyme thiopurine methyltransferase (TPMT) is regulated by a common genetic polymorphism. One in 300 individuals lack enzyme activity and 11% are heterozygous for a variant low activity allele and have an intermediate activity. The thiopurine drugs azathioprine, mercaptopurine and thioguanine are substrates for TPMT; these drugs exhibit well documented myelosuppressive effects on haematopoietic cells and have a track record of idiosyncratic drug reactions. The development of severe bone marrow toxicity, in patients taking standard doses of thiopurine drugs, is associated with TPMT deficiency whilst the TPMT heterozygote is at an increased risk of developing myelosuppression. Factors influencing TPMT enzyme activity, as measured in the surrogate red blood cell, are discussed in this review to enable an appreciation of why concordance between TPMT genotype and phenotype is not 100%. This is particularly important for lower/intermediate TPMT activities to avoid misclassification of TPMT status. TPMT testing is now widely available in routine service laboratories. The British National Formulary suggests TPMT testing before starting thiopurine drugs. Dermatologists were quick to adopt routine TPMT testing whilst gastroenterologists do not specifically recommend TPMT screening. TPMT testing is mandatory prior to the use of mercaptopurine in childhood leukaemia. Thiopurine drug dose and other treatment related influences on cell counts explain some of the differing recommendations between clinical specialities. TPMT testing is cost-effective and the major role is in the identification of the TPMT deficient individual prior to the start of thiopurine drugs. PMID:23962279

  5. Tickborne Powassan virus infections among Wisconsin residents.

    PubMed

    Johnson, Diep K Hoang; Staples, J Erin; Sotir, Mark J; Warshauer, David M; Davis, Jeffrey P

    2010-04-01

    Powassan virus (POWV) is a tickborne Flavivirus that causes a rare but potentially life-threatening illness. The first reported case of POWV infection in a Wisconsin resident occurred in 2003. Enhanced surveillance and testing detected 2 additional cases. Patient specimens with a positive or equivocal immunoglobulin M (IgM) antibody to an arbovirus were sent from commercial laboratories to the Wisconsin State Laboratory of Hygiene and forwarded to the Centers for Disease Control and Prevention (CDC) for confirmatory testing. Patients with laboratory confirmed POWV infections were interviewed to obtain demographic, clinical, and epidemiologic information. POWV infections were confirmed in 3 adult Wisconsin residents in 2003, 2006, and 2007; illness onsets occurred during May and June. Two patients were hospitalized and all survived. One patient had a dual infection with POWV and Anaplasma phaghocytophilum. Specimens from all 3 patients were initially reported as positive for IgM antibody to either St Louis encephalitis or California serogroup viruses; POWV-specific antibody was detected during confirmatory testing at the CDC. Each patient had exposures to known or likely tick habitats in different counties within 30 days before illness onset. These are the first diagnosed human POWV infections in Wisconsin. Because all 3 patients were initially identified as having other arboviral infections using commercial screening kits, routine confirmatory testing is essential for proper diagnosis of most arboviral infections. Wisconsin residents should be educated regarding risks of acquiring and ways to prevent POWV infection and other tickborne diseases when spending time outdoors.

  6. C-reactive protein for the early prediction of anastomotic leak after esophagectomy in both neoadjuvant and non-neoadjuvant therapy case: a propensity score matching analysis

    PubMed Central

    Park, Jae Kil; Moon, Seok Whan

    2017-01-01

    Background Anastomotic leak is one of most significant causes of mortality after esophagectomy. Therefore, it is clinically valuable to detect anastomotic leak early after esophagectomy in esophageal cancer. The purpose of this study is to investigate the associations between routine postoperative laboratory findings and anastomotic leak and to analyze the laboratory findings to find out an independent predictive marker for anastomotic leak. In addition, this study compares cases treated with neoadjuvant therapy (NT) and those without (non-NT). Methods We retrospectively assessed the medical records of 201 consecutive cases that met this study’s criteria from January 2009 to December 2016. All patients underwent curative and complete esophagectomy for intra-thoracic esophageal cancer. We compiled and analyzed routine laboratory findings from the day before surgery to the eighth postoperative day on a daily basis. Routine laboratory tests consisted of 26 separate tests, including complete blood cell counts, blood chemistries, as well as erythrocyte sedimentation rate and C-reactive protein (CRP). Barium esophagogram with chest computed tomography (CT) was performed on the seventh postoperative day to evaluate the presence of an anastomotic leak. Results A total of 45 of 201 patients underwent NT. Anastomotic leaks were found in 23 (11.4%) of 201 patients (8 patients in NT and 15 patients in non-NT). White blood cell (WBC) from the second postoperative day (P=0.031, P=0.006, P=0.007, P=0.007, P=0.041, and P=0.003, respectively) and CRP from the third postoperative day (P=0.012, P<0.001, P=0.014, P<0.001, P=0.001, and P=0.006, respectively) were associated with anastomotic leak in non-NT; however, only CRP on the third, fifth, sixth, and seventh postoperative days (P=0.041, P=0.037, P=0.002, and P=0.003, respectively) was associated with anastomotic leak in NT. The CRP level on the third postoperative day was a significant independent predictive marker of anastomotic leak (P=0.041, odd ratio (OR) 1.056, 95% confidential interval (CI): 1.002–1.113) and had a significant diagnostic cutoff value for the development of anastomotic leak (non-NT: cutoff value 17.12 mg/dL, sensitivity 69.2%, specificity 78.1%, P<0.001, area 0.822; NT: cutoff value 16.42 mg/dL, sensitivity 80.0%, specificity 70.0%, P=0.042, area 0.7104). Conclusions There were divergent laboratory findings reflective of anastomotic leak between patients who underwent NT and those who did not. The CRP level on the third postoperative day had a significant cutoff value for early detection of anastomotic leak after esophagectomy in both NT and non-NT groups. PMID:29268376

  7. Mass spectrometric characterization of the hypoxia-inducible factor (HIF) stabilizer drug candidate BAY 85-3934 (molidustat) and its glucuronidated metabolite BAY-348, and their implementation into routine doping controls.

    PubMed

    Dib, Josef; Mongongu, Cynthia; Buisson, Corinne; Molina, Adeline; Schänzer, Wilhelm; Thuss, Uwe; Thevis, Mario

    2017-01-01

    The development of new therapeutics potentially exhibiting performance-enhancing properties implicates the risk of their misuse by athletes in amateur and elite sports. Such drugs necessitate preventive anti-doping research for consideration in sports drug testing programmes. Hypoxia-inducible factor (HIF) stabilizers represent an emerging class of therapeutics that allows for increasing erythropoiesis in patients. BAY 85-3934 is a novel HIF stabilizer, which is currently undergoing phase-2 clinical trials. Consequently, the comprehensive characterization of BAY 85-3934 and human urinary metabolites as well as the implementation of these analytes into routine doping controls is of great importance. The mass spectrometric behaviour of the HIF stabilizer drug candidate BAY 85-3934 and a glucuronidated metabolite (BAY-348) were characterized by electrospray ionization-(tandem) mass spectrometry (ESI-MS(/MS)) and multiple-stage mass spectrometry (MS n ). Subsequently, two different laboratories established different analytical approaches (one each) enabling urine sample analyses by employing either direct urine injection or solid-phase extraction. The methods were cross-validated for the metabolite BAY-348 that is expected to represent an appropriate target analyte for human urine analysis. Two test methods allowing for the detection of BAY-348 in human urine were applied and cross-validated concerning the validation parameters specificity, linearity, lower limit of detection (LLOD; 1-5 ng/mL), ion suppression/enhancement (up to 78%), intra- and inter-day precision (3-21%), recovery (29-48%), and carryover. By means of ten spiked test urine samples sent blinded to one of the participating laboratories, the fitness-for-purpose of both assays was provided as all specimens were correctly identified applying both testing methods. As no post-administration study samples were available, analyses of authentic urine specimens remain desirable. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Implementation of biological variation-based analytical performance specifications in the laboratory: Stringent evaluation of Improvacutor blood collection tubes.

    PubMed

    Chung, Hee-Jung; Song, Yoon Kyung; Hong, Sung Kuk; Hwang, Sang-Hyun; Seo, Hee Seung; Whang, Dong Hee; Nam, Myung-Hyun; Lee, Do Hoon

    2017-01-01

    Recently, because the quality of laboratory analyses has increased along with the need for quality improvement, several external quality control bodies have adapted performance specifications using the Desirable Biological Variation Database, termed "Ricos goals"; these criteria are more stringent than those presented in CLIA 88. In this study, we aimed to validate newly introduced serum separator tubes, Improvacutor, for routine clinical chemistry testing in accordance with Ricos goals and CLIA 88. Blood samples were collected from 100 volunteers into three types of serum vacuum tubes: Greiner Vacuette, Becton Dickinson (BD) Vacutainer, and Improve Improvacutor. The samples were subjected to 16 routine chemistry tests using a TBA-200fr NEO chemistry autoanalyzer. In the comparison analysis, all 16 test results were acceptable according to CLIA 88. However, in the comparison of Improve and BD tubes, creatinine showed 4.31% (+0.08 μmol/L) bias. This slightly exceeded the Desirable Specification for Inaccuracy Ricos limit of ±3.96%, but still satisfied the CLIS88 limit of ±26.52 μmol/L. The remaining 15 analytes performed acceptably according to the Desirable Specifications of Ricos. The correlation coefficient of 12 analytes was greater than 0.95 in Passing-Bablok regression analysis among the three tubes, but was lower for four analytes: calcium, sodium, potassium, and chloride. In the stability assay, only potassium tested in the Greiner tube revealed a larger positive bias (2.18%) than the Ricos Desirable Specification for Inaccuracy based on biologic variation (1.8%). The BD tube also showed a positive bias of 1.74%, whereas the new Improve tube showed the smallest positive bias of 1.17% in potassium level after 72 h storage. Thus, the results of this study demonstrate that recently introduced analytical performance specifications based on components of biological variation (Rico's goal) could be extended to criterion for performance evaluation and applied.

  9. Quality-assurance results for routine water analyses in U.S. Geological Survey laboratories, water year 1998

    USGS Publications Warehouse

    Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.

    2000-01-01

    The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).

  10. Collection fluid helps preservation in voided urine cytology.

    PubMed

    Raistrick, J; Shambayati, B; Dunsmuir, W

    2008-04-01

    Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.

  11. Progress toward measles elimination--Western Pacific Region, 2009-2012.

    PubMed

    2013-06-07

    In 2005, the World Health Organization (WHO) Regional Committee for the Western Pacific Region (WPR) resolved that WPR should aim to eliminate measles by 2012. The recommended measles elimination strategies in WPR include 1) achieving and maintaining high (≥95%) coverage with 2 doses of measles-containing vaccine (MCV) through routine immunization services and by implementing supplementary immunization activities (SIAs), when required; 2) conducting high-quality, case-based measles surveillance; 3) ensuring high-quality laboratory surveillance, with timely and accurate testing of specimens to confirm or discard suspected cases and detect measles virus for genotyping and molecular analysis; and 4) establishing and maintaining measles outbreak preparedness for rapid response and ensuring appropriate case management. This report updates the previous report and describes progress toward eliminating measles in WPR during 2009-2012. During this period, measles incidence reached a historic low, decreasing by 83%, from 34.0 to 5.9 cases per million population. However, to achieve measles elimination in WPR, additional efforts are needed to strengthen routine immunization services in countries and areas with <95% coverage with the routine first (MCV1) or second dose of MCV (MCV2), to introduce a MCV2 dose in the four remaining countries and areas that do not yet have a routine 2-dose MCV schedule, and to use SIAs to close immunity gaps among measles-susceptible populations in countries and areas that have ongoing measles virus transmission.

  12. Comparison of Saramis 4.12 and IVD 3.0 Vitek MS Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Mycobacteria from Solid and Liquid Culture Media.

    PubMed

    Leyer, Caroline; Gregorowicz, Guillaume; Mougari, Faiza; Raskine, Laurent; Cambau, Emmanuelle; de Briel, Dominique

    2017-07-01

    During the last decade, many investigators have studied matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) for identification of mycobacteria. Diverse and contradictory results indicated that optimal level for routine testing has not been reached yet. This work aimed to assess Vitek MS through two distinct versions, Saramis v4.12 RUO and the IVD v3.0, under conditions close to routine laboratory practice. Overall, 111 mycobacterial isolates were subjected to protein extraction and same spectra were matched against both databases. The IVD v3.0 database proved to be superior to Saramis v4.12 and its identification rates remarkably increased, from 67% to 94% for isolates grown on Middlebrook 7H10 solid medium and from 62% to 91% for isolates grown on mycobacterial growth indicator tube (MGIT) liquid medium. With this new version, IVD v3.0, MALDI-TOF MS might be integrated into routine clinical diagnostics, although molecular techniques remain mandatory in some cases. Copyright © 2017 American Society for Microbiology.

  13. Microbial ecology laboratory procedures manual NASA/MSFC

    NASA Technical Reports Server (NTRS)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  14. Antenatal screening for Down syndrome: a quantitative demonstration of the improvements over the past 20 years.

    PubMed

    Renshaw, Richard; Ellis, Katrina; Jacobs, Patricia; Morris, Joan

    2013-10-01

    Pregnant women who receive a high screening risk result for Down, Edwards or Patau syndrome are offered diagnostic tests that carry a procedure-related risk of miscarriage. This study quantifies the improvement in the screening tests by calculating the number of women who had such tests per syndrome diagnosis from 1991 to 2010. Routinely stored data on prenatal chorionic villus sampling (CVS) and amniocentesis samples performed from 1991 to 2010 from the Wessex Regional Genetics Laboratory in England were extracted from the laboratory database. The numbers of diagnostic tests performed per Down, Edwards or Patau syndrome diagnosis were calculated according to the type of diagnostic test, and were adjusted for maternal age and gestational age at diagnosis. A total of 32,345 CVSs and amniocenteses identified 872 diagnoses of Down syndrome and 328 of Edwards and Patau syndrome. In 1991, there were 46 (95%CI: 16-111) CVSs per syndrome diagnosis compared with five (95%CI: 4-7) in 2010. For amniocenteses, the number fell from 53 (37-78) to 15 (11-22). This analysis demonstrates the improvements in antenatal screening for Down syndrome that have been made over the past 20 years, resulting in a reduction in the number of women tested and thus in the number of foetal deaths attributable to the testing procedure.

  15. A Rare Non-Hemolytic Case of Idiopathic Cold Agglutinin Disease.

    PubMed

    Erkus, Edip; Kocak, Mehmet Z; Aktas, Gulali; Ozen, Mehmet; Atak, Burcin M; Duman, Tuba T; Tekce, Buket K; Savli, Haluk

    2018-06-01

    Cold agglutinin disease is a very rare condition associated with agglutination of erythrocytes in cold environment usually due to IgM type antibodies. Other than hemolytic anemias, it may interfere with routine hemogram tests due to miscalculation of red blood cell count (RBC) and other hemogram parameters calculated with involvement of RBC. Awareness of the condition is important to overcome laboratory errors. We studied a peripheral blood smear and repeated the hemogram test at 37°C to establish the diagnosis of cold agglutinin disease. Initial hemogram test results of the fifty-eight year-old man was as follows: RBC: 1.34 M/µL, hemoglobin (Hb): 12.4 g/dL, hematocrit (Htc): 11.8%, mean corpuscular hemoglobin (MCH): 92.4 pg, and mean corpuscular hemoglobin concentration (MCHC): 105 gr/dL. Despite the standard indirect Coombs test being negative, repeated tests at room temperature was 4+. We suspected cold agglutinin disease and repeated the hemogram test using the Bain-Marie method at 37°C and the test results showed RBC: 3.4 M/µL, hemoglobin: 12.6 g/dL, hematocrit: 30.2%, MCH: 31.7 pg, and MCHC: 41.8 g/dL. Inappropriate hemogram results may be a sign of underlying cold agglutinin disease. Hemolytic anemia not always accompanies the disease; however, cold exposure may trigger erythrocyte agglutination in vitro and may cause erratic laboratory results.

  16. Hematocrit Levels, Blood Testing, and Blood Transfusion in Infants After Heart Surgery.

    PubMed

    Delgado-Corcoran, Claudia; Wolpert, Katherine H; Lucas, Kathryn; Bodily, Stephanie; Presson, Angela P; Bratton, Susan L

    2016-11-01

    To determine whether judicious blood testing impacts timing or amount of packed RBC transfusions in infants after heart surgery. A retrospective study comparing before and after initiation of a quality improvement process. A university-affiliated cardiac ICU at a tertiary care children's hospital. Infants less than 1 year old with Risk Adjustment for Congenital Heart Surgery category 4, 5, 6, or d-transposition of great arteries (Risk Adjustment for Congenital Heart Surgery 3) consecutively treated during 2010 through 2013. A quality improvement process implemented in 2011 to decrease routine laboratory testing after surgery. Fifty-two infants preintervention and 214 postintervention had similar age, weight, proportion of cyanotic lesions, and surgical complexity. Infants with single versus biventricular physiology were compared separately. The number of laboratory tests per patient adjusted for cardiac ICU length of stay (laboratory tests/patient/day) was significantly lower in postintervention populations for single and biventricular groups (9 vs 15 and 10 vs 15, respectively; p < 0.001). The proportion of single ventricle patients transfused post- and preintervention was not statistically different (72% vs 90%; p = 0.130). Transfusion in the biventricular groups was the same over time (65% vs 65%). Time to first transfusion was significantly longer in the postintervention single ventricle group (4 vs 1 d; p < 0.001), and was not statistically different in the biventricular patients (4 vs 7 d; p = 0.058). The median hematocrit level at first transfusion was significantly lower (37% vs 40%; p = 0.004) postintervention in the cyanotic population, but did not differ in the biventricular group (31% vs 31%; p = 0.840). In infants after heart surgery, blood testing targeted to individual needs significantly decreased the number of blood tests, but did not significantly decrease postoperative blood transfusion.

  17. External quality-assurance results for the National Atmospheric Deposition Program and the National Trends Network during 1986

    USGS Publications Warehouse

    See, Randolph B.; Schroder, LeRoy J.; Willoughby, Timothy C.

    1988-01-01

    During 1986, the U.S. Geological Survey operated three programs to provide external quality-assurance monitoring of the National Atmospheric Deposition Program and National Trends Network. An intersite-comparison program was used to assess the accuracy of onsite pH and specific-conductance determinations at quarterly intervals. The blind-audit program was used to assess the effect of routine sample handling on the precision and bias of program and network wet-deposition data. Analytical results from four laboratories, which routinely analyze wet-deposition samples, were examined to determine if differences existed between laboratory analytical results and to provide estimates of the analytical precision of each laboratory. An average of 78 and 89 percent of the site operators participating in the intersite-comparison met the network goals for pH and specific conductance. A comparison of analytical values versus actual values for samples submitted as part of the blind-audit program indicated that analytical values were slightly but significantly (a = 0.01) larger than actual values for pH, magnesium, sodium, and sulfate; analytical values for specific conductance were slightly less than actual values. The decreased precision in the analyses of blind-audit samples when compared to interlaboratory studies indicates that a large amount of uncertainty in network deposition data may be a result of routine field operations. The results of the interlaboratory comparison study indicated that the magnitude of the difference between laboratory analyses was small for all analytes. Analyses of deionized, distilled water blanks by participating laboratories indicated that the laboratories had difficulty measuring analyte concentrations near their reported detection limits. (USGS)

  18. Prevalence of Staphylococcus, including Methicillin-Resistant Staphylococcus aureus, in a Physical Therapy Education Facility.

    PubMed

    Dhagat, Priya V; Gibbs, Karen A; Rohde, Rodney E

    2015-01-01

    The purpose of this study was to assess the prevalence of Staphylococcus species, including methicillin-resistant Staphylococcus aureus (MRSA), in a physical therapy (PT) education facility. The PT laboratory classrooms were routinely used by graduate PT students and faculty, undergraduate anatomy students, and licensed practitioners for continuing education purposes. A total of 88 swab samples were collected from plinths and other equipment and plated onto mannitol salt agar (MSA). Suspected S. aureus colonies were confirmed by Staphyloslide latex testing. S. aureus isolates were plated to HardyCHROM agar to identify MRSA. VITEK antibiotic susceptibility testing confirmed MRSA isolates. Forty-seven samples showed growth (47/88, 53%), and 7 tested positive for S. aureus (7/47, 15%). Of those 7, one demonstrated oxacillin resistance and was confirmed as MRSA (1/7, 2%). Remaining samples grew other species of Staphylococcus and gram-negative bacilli. Given high classroom utilization, staphylococci environmental prevalence would be expected. However, the presence of MRSA was unexpected. Results demonstrate the potential for easily transmissible and potentially harmful organisms to be present in multi-use classrooms utilized by health professions students where frequent skin-to-skin contact occurs. Strict, routine cleaning of plinths and other equipment is imperative in reducing exposure risk.

  19. [A Case of Severe Legionella longbeachae Pneumonia and Usefulness of LAMP Assay].

    PubMed

    Matsushita, Kumiko; Hijikuro, Kohei; Arita, Shohei; Kaneko, Yu; Isozaki, Masahiro

    2017-08-15

    Urinary antigen test is frequently used as a routine laboratory test for early diagnosis of Legionella infection , which is especially suitable for ordinary Legionella pneumophila serogroup 1, but not for other types of Legionella . We report a case of severe pneumonia caused by Legionella longbeachae , where a method of loop-mediated isothermal amplification (LAMP) assay contributed an important role for the early detection. This case involved an 83-year-old man who developed fever, dyspnea, and productive cough. Since the medication of prescribed ceftriaxone had not been effective, he visited the emergency room of our hospital, where an X-ray revealed a severe pneumonia harboring a consolidation with air bronchogram in his right lower lung. His sputum and urine were subjected to the routine bacterial culture or the urinary antigen test for Legionella , which initially brought negative results. However, a positive result of LAMP assay enabled early diagnosis of Legionella pneumonia . Later, the bacterial cultures of sputum made some progress and 16S rRNA sequencing provided a proof of L. longbeachae . This LAMP assay may bring a benefit for the patients with Legionella pneumonia by enabling early detection of not only specific L. pneumophila serogroup 1, but also of the other Legionella species.

  20. Sequim Marine Research Laboratory routine environmental measurements during CY-1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fix, J.J.; Blumer, P.J.

    1978-06-01

    Beginning in 1976, a routine environmental program was established at the Marine Research Laboratory (MRL) at Sequim, Washington. The program is intended to demonstrate the negligible impact of current MRL operations on the surrounding environs and to provide baseline data through which any cumulative impact could be detected. The sampling frequency is greater during the first 2 years of the program to provide sufficient initial information to allow reliable estimates of observed radionuclide concentrations and to construct a long-term sampling program. The program is designed, primarily, to determine levels of radioactivity present in selected biota in Sequim Bay. The biotamore » were selected because of their presence near the laboratory and their capacity to concentrate trace elements. Other samples were obtained to determine the radionuclides in Sequim Bay and laboratory drinking water, as well as the ambient radiation exposure levels and surface deposition of fallout radionuclides for the laboratory area. Appendix A provides a summary of the analytical methods used. The present document includes data obtained during CY 1977 in addition to CY-1976 data published previously.« less

  1. Preparation of bone samples in the Gliwice Radiocarbon Laboratory for AMS radiocarbon dating.

    PubMed

    Piotrowska, N; Goslar, T

    2002-12-01

    In the Gliwice Radiocarbon Laboratory, a system for preparation of samples for AMS dating has been built. At first it was used to produce graphite targets from plant macrofossils and sediments. In this study we extended its capabilities with the preparation of bones. We dealt with 3 methods; the first was the classical Longin method of collagen extraction, the second one included additional treatment of powdered bone in alkali solution, while in the third one carboxyl carbon was separated from amino acids obtained after hydrolysis of protein. The suitability of the methods was tested on 2 bone samples. Most of our samples gave ages > 40 kyr BP, suggesting good performance of the adapted methods, except for one sample prepared with simple Longin method. For routine preparation of bones we chose the Longin method with additional alkali treatment.

  2. Candida bloodstream infection: a clinical microbiology laboratory perspective.

    PubMed

    Pongrácz, Júlia; Kristóf, Katalin

    2014-09-01

    The incidence of Candida bloodstream infection (BSI) has been on the rise in several countries worldwide. Species distribution is changing; an increase in the percentage of non-albicans species, mainly fluconazole non-susceptible C. glabrata was reported. Existing microbiology diagnostic methods lack sensitivity, and new methods need to be developed or further evaluation for routine application is necessary. Although reliable, standardized methods for antifungal susceptibility testing are available, the determination of clinical breakpoints remains challenging. Correct species identification is important and provides information on the intrinsic susceptibility profile of the isolate. Currently, acquired resistance in clinical Candida isolates is rare, but reports indicate that it could be an issue in the future. The role of the clinical microbiology laboratory is to isolate and correctly identify the infective agent and provide relevant and reliable susceptibility data as soon as possible to guide antifungal therapy.

  3. Different spectrophotometric methods applied for the analysis of simeprevir in the presence of its oxidative degradation product: Acomparative study

    NASA Astrophysics Data System (ADS)

    Attia, Khalid A. M.; El-Abasawi, Nasr M.; El-Olemy, Ahmed; Serag, Ahmed

    2018-02-01

    Five simple spectrophotometric methods were developed for the determination of simeprevir in the presence of its oxidative degradation product namely, ratio difference, mean centering, derivative ratio using the Savitsky-Golay filters, second derivative and continuous wavelet transform. These methods are linear in the range of 2.5-40 μg/mL and validated according to the ICH guidelines. The obtained results of accuracy, repeatability and precision were found to be within the acceptable limits. The specificity of the proposed methods was tested using laboratory prepared mixtures and assessed by applying the standard addition technique. Furthermore, these methods were statistically comparable to RP-HPLC method and good results were obtained. So, they can be used for the routine analysis of simeprevir in quality-control laboratories.

  4. GPS Data Analysis for Earth Orientation at the Jet Propulsion Laboratory

    NASA Technical Reports Server (NTRS)

    Zumberge, J.; Webb, F.; Lindqwister, U.; Lichten, S.; Jefferson, D.; Ibanez-Meier, R.; Heflin, M.; Freedman, A.; Blewitt, G.

    1994-01-01

    Beginning June 1992 and continuing indefinitely as part of our contribution to FLINN (Fiducial Laboratories for an International Natural Science Network), DOSE (NASA's Dynamics of the Solid Earth Program), and the IGS (International GPS Geodynamics Service), analysts at the Jet Propulsion Laboratory (JPL) have routinely been reducing data from a globally-distributed network of Rogue Global Positioning System (GPS) receivers.

  5. Evaluation of the implementation of a quality system in a basic research laboratory: viability and impacts.

    PubMed

    Fraga, Hilda Carolina de Jesus Rios; Fukutani, Kiyoshi Ferreira; Celes, Fabiana Santana; Barral, Aldina Maria Prado; Oliveira, Camila Indiani de

    2012-01-01

    To evaluate the process of implementing a quality management system in a basic research laboratory of a public institution, particularly considering the feasibility and impacts of this improvement. This was a prospective and qualitative study. We employed the norm "NIT DICLA 035--Princípios das Boas Práticas de Laboratório (BPL)" and auxiliary documents of Organisation for Economic Co-operation and Development to complement the planning and implementation of a Quality System, in a basic research laboratory. In parallel, we used the PDCA tool to define the goals of each phase of the implementation process. This study enabled the laboratory to comply with the NIT DICLA 035 norm and to implement this norm during execution of a research study. Accordingly, documents were prepared and routines were established such as the registration of non-conformities, traceability of research data and equipment calibration. The implementation of a quality system, the setting of a laboratory focused on basic research is feasible once certain structural changes are made. Importantly, impacts were noticed during the process, which could be related to several improvements in the laboratory routine.

  6. Clinical protein mass spectrometry.

    PubMed

    Scherl, Alexander

    2015-06-15

    Quantitative protein analysis is routinely performed in clinical chemistry laboratories for diagnosis, therapeutic monitoring, and prognosis. Today, protein assays are mostly performed either with non-specific detection methods or immunoassays. Mass spectrometry (MS) is a very specific analytical method potentially very well suited for clinical laboratories. Its unique advantage relies in the high specificity of the detection. Any protein sequence variant, the presence of a post-translational modification or degradation will differ in mass and structure, and these differences will appear in the mass spectrum of the protein. On the other hand, protein MS is a relatively young technique, demanding specialized personnel and expensive instrumentation. Many scientists and opinion leaders predict MS to replace immunoassays for routine protein analysis, but there are only few protein MS applications routinely used in clinical chemistry laboratories today. The present review consists of a didactical introduction summarizing the pros and cons of MS assays compared to immunoassays, the different instrumentations, and various MS protein assays that have been proposed and/or are used in clinical laboratories. An important distinction is made between full length protein analysis (top-down method) and peptide analysis after enzymatic digestion of the proteins (bottom-up method) and its implication for the protein assay. The document ends with an outlook on what type of analyses could be used in the future, and for what type of applications MS has a clear advantage compared to immunoassays. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Technical Proposal for Loading 3000 Gallon Crude Oil Samples from Field Terminal to Sandia Pressurized Tanker to Support US DOE/DOT Crude Oil Characterization Research Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lord, David L.; Allen, Raymond

    Sandia National Laboratories is seeking access to crude oil samples for a research project evaluating crude oil combustion properties in large-scale tests at Sandia National Laboratories in Albuquerque, NM. Samples must be collected from a source location and transported to Albuquerque in a tanker that complies with all applicable regulations for transportation of crude oil over public roadways. Moreover, the samples must not gain or lose any components, to include dissolved gases, from the point of loading through the time of combustion at the Sandia testing facility. In order to achieve this, Sandia designed and is currently procuring a custommore » tanker that utilizes water displacement in order to achieve these performance requirements. The water displacement procedure is modeled after the GPA 2174 standard “Obtaining Liquid Hydrocarbons Samples for Analysis by Gas Chromatography” (GPA 2014) that is used routinely by crude oil analytical laboratories for capturing and testing condensates and “live” crude oils, though it is practiced at the liter scale in most applications. The Sandia testing requires 3,000 gallons of crude. As such, the water displacement method will be upscaled and implemented in a custom tanker. This report describes the loading process for acquiring a ~3,000 gallon crude oil sample from commercial process piping containing single phase liquid crude oil at nominally 50-100 psig. This document contains a general description of the process (Section 2), detailed loading procedure (Section 3) and associated oil testing protocols (Section 4).« less

  8. Air sampling to assess potential generation of aerosolized viable bacteria during flow cytometric analysis of unfixed bacterial suspensions

    PubMed Central

    Carson, Christine F; Inglis, Timothy JJ

    2018-01-01

    This study investigated aerosolized viable bacteria in a university research laboratory during operation of an acoustic-assisted flow cytometer for antimicrobial susceptibility testing by sampling room air before, during and after flow cytometer use. The aim was to assess the risk associated with use of an acoustic-assisted flow cytometer analyzing unfixed bacterial suspensions. Air sampling in a nearby clinical laboratory was conducted during the same period to provide context for the existing background of microorganisms that would be detected in the air. The three species of bacteria undergoing analysis by flow cytometer in the research laboratory were Klebsiella pneumoniae, Burkholderia thailandensis and Streptococcus pneumoniae. None of these was detected from multiple 1000 L air samples acquired in the research laboratory environment. The main cultured bacteria in both locations were skin commensal and environmental bacteria, presumed to have been disturbed or dispersed in laboratory air by personnel movements during routine laboratory activities. The concentrations of bacteria detected in research laboratory air samples were reduced after interventional cleaning measures were introduced and were lower than those in the diagnostic clinical microbiology laboratory. We conclude that our flow cytometric analyses of unfixed suspensions of K. pneumoniae, B. thailandensis and S. pneumoniae do not pose a risk to cytometer operators or other personnel in the laboratory but caution against extrapolation of our results to other bacteria and/or different flow cytometric experimental procedures. PMID:29608197

  9. Sigma metrics used to assess analytical quality of clinical chemistry assays: importance of the allowable total error (TEa) target.

    PubMed

    Hens, Koen; Berth, Mario; Armbruster, Dave; Westgard, Sten

    2014-07-01

    Six Sigma metrics were used to assess the analytical quality of automated clinical chemistry and immunoassay tests in a large Belgian clinical laboratory and to explore the importance of the source used for estimation of the allowable total error. Clinical laboratories are continually challenged to maintain analytical quality. However, it is difficult to measure assay quality objectively and quantitatively. The Sigma metric is a single number that estimates quality based on the traditional parameters used in the clinical laboratory: allowable total error (TEa), precision and bias. In this study, Sigma metrics were calculated for 41 clinical chemistry assays for serum and urine on five ARCHITECT c16000 chemistry analyzers. Controls at two analyte concentrations were tested and Sigma metrics were calculated using three different TEa targets (Ricos biological variability, CLIA, and RiliBÄK). Sigma metrics varied with analyte concentration, the TEa target, and between/among analyzers. Sigma values identified those assays that are analytically robust and require minimal quality control rules and those that exhibit more variability and require more complex rules. The analyzer to analyzer variability was assessed on the basis of Sigma metrics. Six Sigma is a more efficient way to control quality, but the lack of TEa targets for many analytes and the sometimes inconsistent TEa targets from different sources are important variables for the interpretation and the application of Sigma metrics in a routine clinical laboratory. Sigma metrics are a valuable means of comparing the analytical quality of two or more analyzers to ensure the comparability of patient test results.

  10. The main challenges that remain in applying high-throughput sequencing to clinical diagnostics.

    PubMed

    Loeffelholz, Michael; Fofanov, Yuriy

    2015-01-01

    Over the last 10 years, the quality, price and availability of high-throughput sequencing instruments have improved to the point that this technology may be close to becoming a routine tool in the diagnostic microbiology laboratory. Two groups of challenges, however, have to be resolved in order to move this powerful research technology into routine use in the clinical microbiology laboratory. The computational/bioinformatics challenges include data storage cost and privacy concerns, requiring analysis to be performed without access to cloud storage or expensive computational infrastructure. The logistical challenges include interpretation of complex results and acceptance and understanding of the advantages and limitations of this technology by the medical community. This article focuses on the approaches to address these challenges, such as file formats, algorithms, data collection, reporting and good laboratory practices.

  11. Investigations Into Life Science.

    ERIC Educational Resources Information Center

    Mentzer, Dean Samuel

    This laboratory manual, containing 44 exercises, is intended to be used as part of an audio-tutorial approach to laboratory work in a life-science course for student nurses. Exercises include basic techniques of miscroscopy, microbiology, electrophysiology, routine biochemical analyses of blood and urine, and microscopic examination of prepared…

  12. Laboratory testing for cytomegalovirus among pregnant women in the United States: a retrospective study using administrative claims data

    PubMed Central

    2012-01-01

    Background Routine cytomegalovirus (CMV) screening during pregnancy is not recommended in the United States and the extent to which it is performed is unknown. Using a medical claims database, we computed rates of CMV-specific testing among pregnant women. Methods We used medical claims from the 2009 Truven Health MarketScan® Commercial databases. We computed CMV-specific testing rates using CPT codes. Results We identified 77,773 pregnant women, of whom 1,668 (2%) had a claim for CMV-specific testing. CMV-specific testing was significantly associated with older age, Northeast or urban residence, and a diagnostic code for mononucleosis. We identified 44 women with a diagnostic code for mononucleosis, of whom 14% had CMV-specific testing. Conclusions Few pregnant women had CMV-specific testing, suggesting that screening for CMV infection during pregnancy is not commonly performed. In the absence of national surveillance for CMV infections during pregnancy, healthcare claims are a potential source for monitoring practices of CMV-specific testing. PMID:23198949

  13. Enhanced laboratory capacity development: a boost for effective tuberculosis control in resource-limited settings.

    PubMed

    Alabi, Abraham Sunday; Traoré, Afsatou Ndama; Loembe, Marguerite Massinga; Ateba-Ngoa, Ulysse; Frank, Matthias; Adegnika, Ayola Akim; Lell, Bertrand; Mahoumbou, Jocelyn; Köhler, Carsten; Kremsner, Peter Gottfried; Grobusch, Martin Peter

    2017-03-01

    Both routine and research tuberculosis (TB) laboratory capacity urgently need to be expanded in large parts of Sub-Saharan Africa. In 2009, the Centre de Recherches Médicales de Lambaréné (CERMEL) took a strategic decision to expand its activities by building TB laboratory capacity to address research questions and to improve routine diagnostic and treatment capacity. Over the past 7 years, a standard laboratory has been developed that is contributing significantly to TB diagnosis, treatment, and control in Gabon; training has also been provided for TB research staff in Central Africa. CERMEL has a cordial relationship with the Gabon National TB Control Programme (PNLT), which has culminated in a successful Global Fund joint application. This endeavour is considered a model for similar developments needed in areas of high TB prevalence and where TB control remains poor to date. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  14. Performance of two MALDI-TOF MS systems for the identification of yeasts isolated from bloodstream infections and cerebrospinal fluids using a time-saving direct transfer protocol.

    PubMed

    Hamprecht, Axel; Christ, Sara; Oestreicher, Tanja; Plum, Georg; Kempf, Volkhard A J; Göttig, Stephan

    2014-04-01

    The rapid and correct identification of pathogens is of paramount importance for the treatment of patients with invasive infections. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) can speed up the identification of bacteria and fungi and has quickly been embraced by medical microbiology laboratories worldwide. Different MALDI-TOF systems have been compared in studies focussing on identification rates of different pathogens. Another aspect that has not been systematically assessed is the performance in daily routine and handling, which is important especially for microbiology routine laboratories. We compared two widespread commercial systems, Microflex LT Biotyper (Bruker) and VitekMS (bioMérieux), for the identification of 210 relevant clinical yeasts under routine conditions, using a time-saving direct transfer protocol. We assessed the need for an additional extraction step, the threshold for species identification and the duration of measurements with the two systems. The tested yeasts included 34 Candida albicans isolates, 144 non-albicans Candida spp. and 32 yeasts of different genera. The results of the two MS systems were compared with that of biochemical identification and, in case of discrepancies, DNA sequencing of the internal transcribed spacer or the large subunit of ribosomal DNA. Both systems correctly identified 96.2 % of isolates [202/210, non-significant (n.s.)]. Misidentifications were observed for VitekMS only (n = 5, no major errors, n.s.). VitekMS was the slower system (19.8 vs. 8.0 min for 10 samples, p = 0.002) but had the advantage of a more effective direct transfer protocol with less need for an additional extraction step.

  15. Collaborative study to assess the suitability of a candidate International Standard for yellow fever vaccine.

    PubMed

    Ferguson, Morag; Heath, Alan

    2004-12-01

    Yellow fever vaccines are routinely assayed by plaque assay. However, the results of these assays are then converted into mouse LD(50) using correlations/conversion factors which, in many cases, were established many years ago. The minimum required potency in WHO Recommendations is 10(3) LD(50)/dose. Thirteen participants from 8 countries participated in a collaborative study whose aim was to assess the suitability of two candidate preparations to serve as an International Standard for yellow fever vaccine. In addition, the study investigated the relationship between the mouse LD(50) test and plaque forming units with a view to updating the WHO recommendations. Plaque assays were more reproducible than mouse assays, as expected. Differences in sensitivities of plaque assays were observed between laboratories but these differences appear to be consistent within a laboratory for all samples and the expression of potency relative to the candidate standard vaccine improved the reproducibility of assays between laboratories. However, the use of potencies had little effect on the between laboratory variability in mouse LD(50) assays. There appears to be a consistent relationship between overall mean LD(50) and plaques titre for all study preparations other than sample E. The slope of the correlation curve is >1 and it would appear that 10(3) LD(50) is approximately equivalent to 10(4) plaque forming units (PFU), based on the overall means of all laboratory results. The First International Standard for yellow fever vaccine, NIBSC Code 99/616, has been established as the First International Standard for yellow fever vaccine by the Expert Committee of Biological Standards of the World Health Organisation. The International Standard has been arbitrarily assigned a potency of 10(4.5) International Units (IU) per ampoule. Manufacturers and National Control Laboratories are including the First International Standard for yellow fever vaccine in routine assays so that the minimum potency in IU of vaccines released for use and which meet the current minimum potency of 10(3) LD(50) in mouse assays, can be determined. These data will be analysed before a review of the WHO requirements, including the minimum potency per dose, is undertaken.

  16. [Current macro-diagnostic trends of forensic medicine in the Czech Republic].

    PubMed

    Frišhons, Jan; Kučerová, Štěpánka; Jurda, Mikoláš; Sokol, Miloš; Vojtíšek, Tomáš; Hejna, Petr

    2017-01-01

    Over the last few years, advanced diagnostic methods have penetrated in the realm of forensic medicine in addition to standard autopsy techniques supported by traditional X-ray examination and macro-diagnostic laboratory tests. Despite the progress of imaging methods, the conventional autopsy has remained basic and essential diagnostic tool in forensic medicine. Postmortem computed tomography and magnetic resonance imaging are far the most progressive modern radio diagnostic methods setting the current trend of virtual autopsies all over the world. Up to now, only two institutes of forensic medicine have available postmortem computed tomography for routine diagnostic purposes in the Czech Republic. Postmortem magnetic resonance is currently unattainable for routine diagnostic use and was employed only for experimental purposes. Photogrammetry is digital method focused primarily on body surface imaging. Recently, the most fruitful results have been yielded from the interdisciplinary cooperation between forensic medicine and forensic anthropology with the implementation of body scanning techniques and 3D printing. Non-invasive and mini-invasive investigative methods such as postmortem sonography and postmortem endoscopy was unsystematically tested for diagnostic performance with good outcomes despite of limitations of these methods in postmortem application. Other futuristic methods, such as the use of a drone to inspect the crime scene are still experimental tools. The authors of the article present a basic overview of the both routinely and experimentally used investigative methods and current macro-diagnostic trends of the forensic medicine in the Czech Republic.

  17. Rapid targeted somatic mutation analysis of solid tumors in routine clinical diagnostics.

    PubMed

    Magliacane, Gilda; Grassini, Greta; Bartocci, Paola; Francaviglia, Ilaria; Dal Cin, Elena; Barbieri, Gianluca; Arrigoni, Gianluigi; Pecciarini, Lorenza; Doglioni, Claudio; Cangi, Maria Giulia

    2015-10-13

    Tumor genotyping is an essential step in routine clinical practice and pathology laboratories face a major challenge in being able to provide rapid, sensitive and updated molecular tests. We developed a novel mass spectrometry multiplexed genotyping platform named PentaPanel to concurrently assess single nucleotide polymorphisms in 56 hotspots of the 5 most clinically relevant cancer genes, KRAS, NRAS, BRAF, EGFR and PIK3CA for a total of 221 detectable mutations. To both evaluate and validate the PentaPanel performance, we investigated 1025 tumor specimens of 6 different cancer types (carcinomas of colon, lung, breast, pancreas, and biliary tract, and melanomas), systematically addressing sensitivity, specificity, and reproducibility of our platform. Sanger sequencing was also performed for all the study samples. Our data showed that PentaPanel is a high throughput and robust tool, allowing genotyping for targeted therapy selection of 10 patients in the same run, with a practical turnaround time of 2 working days. Importantly, it was successfully used to interrogate different DNAs isolated from routinely processed specimens (formalin-fixed paraffin embedded, frozen, and cytological samples), covering all the requirements of clinical tests. In conclusion, the PentaPanel platform can provide an immediate, accurate and cost effective multiplex approach for clinically relevant gene mutation analysis in many solid tumors and its utility across many diseases can be particularly relevant in multiple clinical trials, including the new basket trial approach, aiming to identify appropriate targeted drug combination strategies.

  18. Genotypic Diversity of Clinical Actinomyces Species: Phenotype, Source, and Disease Correlation among Genospecies

    PubMed Central

    Clarridge III, Jill E.; Zhang, Qing

    2002-01-01

    We determined the frequency distribution of Actinomyces spp. recovered in a routine clinical laboratory and investigated the clinical significance of accurate identification to the species level. We identified 92 clinical strains of Actinomyces, including 13 strains in the related Arcanobacterium-Actinobaculum taxon, by 16S rRNA gene sequence analysis and recorded their biotypes, sources, and disease associations. The clinical isolates clustered into 21 genogroups. Twelve genogroups (74 strains) correlated with a known species, and nine genogroups (17 strains) did not. The individual species had source and disease correlates. Actinomyces turicensis was the most frequently isolated species and was associated with genitourinary tract specimens, often with other organisms and rarely with inflammatory cells. Actinomyces radingae was most often associated with serious, chronic soft tissue abscesses of the breast, chest, and back. Actinomyces europaeus was associated with skin abscesses of the neck and genital areas. Actinomyces lingnae, Actinomyces gravenitzii, Actinomyces odontolyticus, and Actinomyces meyeri were isolated from respiratory specimens, while A. odontolyticus-like strains were isolated from diverse sources. Several of the species were commonly coisolated with a particular bacterium: Actinomyces israelii was the only Actinomyces spp. coisolated with Actinobacillus (Haemophilus) actinomycetemcomitans; Actinomyces meyeri was coisolated with Peptostreptococcus micros and was the only species other than A. israelii associated with sulfur granules in histological specimens. Most genogroups had consistent biotypes (as determined with the RapID ANA II system); however, strains were misidentified, and many codes were not in the database. One biotype was common to several genogroups, with all of these isolates being identified as A. meyeri. Despite the recent description of new Actinomyces spp., 19% of the isolates recovered in our routine laboratory belonged to novel genospecies. One novel group with three strains, Actinomyces houstonensis sp. nov., was phenotypically similar to A. meyeri and A. turicensis but was genotypically closest to Actinomyces neuii. A. houstonensis sp. nov. was associated with abscesses. Our data documented consistent site and disease associations for 21 genogroups of Actinomyces spp. that provide greater insights into appropriate treatments. However, we also demonstrated a complexity within the Actinomyces genus that compromises the biochemical identification of Actinomyces that can be performed in most clinical laboratories. It is our hope that this large group of well-defined strains will be used to find a simple and accurate biochemical test for differentiation of the species in routine laboratories. PMID:12202591

  19. How compliant are technicians with universal safety measures in medical laboratories in Croatia?--A pilot study.

    PubMed

    Dukic, Kristina; Zoric, Matea; Pozaic, Petra; Starcic, Jelena; Culjak, Marija; Saracevic, Andrea; Miler, Marijana

    2015-01-01

    This pilot study aimed to investigate the use of personal protective equipment (PPE) and compliance to the code of conduct (rules defined in institutional, governmental and professional guidelines) among laboratory technicians in Croatian medical laboratories. In addition, we explored the differences in compliance between participants of different age groups, laboratory ownership and accreditation status. An anonymous and voluntary survey with 15 questions was conducted among Croatian medical laboratory technicians (N=217). The questions were divided into two groups: demographic characteristics and the use of PPE. The questions of the second part were graded according to the Likert scale (1-4) and an overall score, shown as median and range (min-max), was calculated for each participant. Differences between the overall scores were tested for each group of participants. The majority of participants always wear protective clothes at work, 38.7% of them always wear gloves in daily routine, more than 30.0% consume food and almost half of them drink beverages at workplace. A significantly lower overall score was found for participants working in public compared to private laboratories (36 (16-40) vs. 40 (31-40), P<0.001). There were no statistically significant differences in overall scores for participants of different age groups (P=0.456) and laboratory accreditation status (P=0.081). A considerable percentage of laboratory technicians in Croatian medical laboratories do not comply with safety measures. Lack of compliance is observed in all personnel regardless laboratory accreditation and participants' age. However, those working in private laboratories adhere more to the code of conduct.

  20. Assessment of readiness for clinical decision support to aid laboratory monitoring of immunosuppressive care at U.S. liver transplant centers.

    PubMed

    Jacobs, J; Weir, C; Evans, R S; Staes, C

    2014-01-01

    Following liver transplantation, patients require lifelong immunosuppressive care and monitoring. Computerized clinical decision support (CDS) has been shown to improve post-transplant immunosuppressive care processes and outcomes. The readiness of transplant information systems to implement computerized CDS to support post-transplant care is unknown. a) Describe the current clinical information system functionality and manual and automated processes for laboratory monitoring of immunosuppressive care, b) describe the use of guidelines that may be used to produce computable logic and the use of computerized alerts to support guideline adherence, and c) explore barriers to implementation of CDS in U.S. liver transplant centers. We developed a web-based survey using cognitive interviewing techniques. We surveyed 119 U.S. transplant programs that performed at least five liver transplantations per year during 2010-2012. Responses were summarized using descriptive analyses; barriers were identified using qualitative methods. Respondents from 80 programs (67% response rate) completed the survey. While 98% of programs reported having an electronic health record (EHR), all programs used paper-based manual processes to receive or track immunosuppressive laboratory results. Most programs (85%) reported that 30% or more of their patients used external laboratories for routine testing. Few programs (19%) received most external laboratory results as discrete data via electronic interfaces while most (80%) manually entered laboratory results into the EHR; less than half (42%) could integrate internal and external laboratory results. Nearly all programs had guidelines regarding pre-specified target ranges (92%) or testing schedules (97%) for managing immunosuppressive care. Few programs used computerized alerting to notify transplant coordinators of out-of-range (27%) or overdue laboratory results (20%). Use of EHRs is common, yet all liver transplant programs were largely dependent on manual paper-based processes to monitor immunosuppression for post-liver transplant patients. Similar immunosuppression guidelines provide opportunities for sharing CDS once integrated laboratory data are available.

Top