Code of Federal Regulations, 2013 CFR
2013-07-01
... REGULATIONS Revised Total Coliform Rule § 141.857 Routine monitoring requirements for public water systems... systems serving more than 1,000 persons. (2) Following any total coliform-positive sample taken under the... calendar month has been completed, systems must determine whether any coliform treatment technique triggers...
Automated acquisition system for routine, noninvasive monitoring of physiological data.
Ogawa, M; Tamura, T; Togawa, T
1998-01-01
A fully automated, noninvasive data-acquisition system was developed to permit long-term measurement of physiological functions at home, without disturbing subjects' normal routines. The system consists of unconstrained monitors built into furnishings and structures in a home environment. An electrocardiographic (ECG) monitor in the bathtub measures heart function during bathing, a temperature monitor in the bed measures body temperature, and a weight monitor built into the toilet serves as a scale to record weight. All three monitors are connected to one computer and function with data-acquisition programs and a data format rule. The unconstrained physiological parameter monitors and fully automated measurement procedures collect data noninvasively without the subject's awareness. The system was tested for 1 week by a healthy male subject, aged 28, in laboratory-based facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Routine monitoring requirements for public water systems serving more than 1,000 people. 141.857 Section 141.857 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Revised Total Coliform Rule §...
Code of Federal Regulations, 2013 CFR
2013-07-01
... WATER REGULATIONS Revised Total Coliform Rule § 141.856 Routine monitoring requirements for subpart H... coliform-positive sample taken under the provisions of this section, systems must comply with the repeat... coliform treatment technique triggers specified in § 141.859 have been exceeded. If any trigger has been...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Routine monitoring requirements for community water systems serving 1,000 or fewer people using only ground water. 141.855 Section 141.855 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Revised...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Routine monitoring requirements for non-community water systems serving 1,000 or fewer people using only ground water. 141.854 Section 141.854 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Routine monitoring requirements for community water systems serving 1,000 or fewer people using only ground water. 141.855 Section 141.855 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Revised...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Routine monitoring requirements for non-community water systems serving 1,000 or fewer people using only ground water. 141.854 Section 141.854 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Routine monitoring requirements for subpart H public water systems serving 1,000 or fewer people. 141.856 Section 141.856 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Revised Total Coliform...
Roberton, Timothy; Kasungami, Dyness; Guenther, Tanya; Hazel, Elizabeth
2016-07-01
Most countries in sub-Saharan Africa have now adopted integrated community case management (iCCM) of common childhood illnesses as a strategy to improve child health. In March 2014, the iCCM Task Force published an Indicator Guide for Monitoring and Evaluating iCCM: a 'menu' of recommended indicators with globally agreed definitions and methodology, to guide countries in developing robust iCCM monitoring systems. The Indicator Guide was conceived as an evolving document that would incorporate collective experience and learning as iCCM programmes themselves evolve. This article presents findings from two studies that examined the feasibility of collecting the Indicator Guide's 18 routine monitoring indicators with the iCCM monitoring systems that countries currently have in place. We reviewed iCCM monitoring tools, protocols and reports from a purposive sample of 10 countries in sub-Saharan Africa. We developed a scorecard system to assess which of the Indicator Guide's 18 routine monitoring indicators could be calculated with the given monitoring tools, and at which level of the health system the relevant information would be available. We found that the data needed to calculate many of the Indicator Guide's routine monitoring indicators are already being collected through existing monitoring systems, although much of these data are only available at health facility level and not aggregated to district or national levels. Our results highlight challenge of using supervision checklists as a data source, and the need for countries to maintain accurate deployment data for CHWs and CHW supervisors. We suggest that some of the recommended indicators need revising. Routine monitoring will be more feasible, effective and efficient if iCCM programmes focus on a smaller set of high-value indicators that are easy to measure, reliably interpreted and useful both for global and national stakeholders and for frontline health workers themselves. © The Author 2016. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
40 CFR 141.132 - Monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... discretion. (2) Chlorite. Community and nontransient noncommunity water systems using chlorine dioxide, for... samples. (ii) Reduced monitoring. Monitoring may not be reduced. (2) Chlorine dioxide—(i) Routine... three chlorine dioxide distribution system samples. If chlorine dioxide or chloramines are used to...
40 CFR 63.9808 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2010 CFR
2010-07-01
... times, you must maintain your monitoring systems including, but not limited to, maintaining necessary parts for routine repairs of the monitoring equipment. (c) Except for, as applicable, monitoring system malfunctions, associated repairs, and required quality assurance or quality control activities, you must...
40 CFR 63.9808 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2014 CFR
2014-07-01
... times, you must maintain your monitoring systems including, but not limited to, maintaining necessary parts for routine repairs of the monitoring equipment. (c) Except for, as applicable, monitoring system malfunctions, associated repairs, and required quality assurance or quality control activities, you must...
40 CFR 63.9808 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2012 CFR
2012-07-01
... times, you must maintain your monitoring systems including, but not limited to, maintaining necessary parts for routine repairs of the monitoring equipment. (c) Except for, as applicable, monitoring system malfunctions, associated repairs, and required quality assurance or quality control activities, you must...
40 CFR 63.9808 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2011 CFR
2011-07-01
... times, you must maintain your monitoring systems including, but not limited to, maintaining necessary parts for routine repairs of the monitoring equipment. (c) Except for, as applicable, monitoring system malfunctions, associated repairs, and required quality assurance or quality control activities, you must...
40 CFR 63.9808 - How do I monitor and collect data to demonstrate continuous compliance?
Code of Federal Regulations, 2013 CFR
2013-07-01
... times, you must maintain your monitoring systems including, but not limited to, maintaining necessary parts for routine repairs of the monitoring equipment. (c) Except for, as applicable, monitoring system malfunctions, associated repairs, and required quality assurance or quality control activities, you must...
Current concepts in blood glucose monitoring
Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini
2013-01-01
Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827
A portable detection system for in vivo monitoring of 131I in routine and emergency situations
NASA Astrophysics Data System (ADS)
Lucena, EA; Dantas, ALA; Dantas, BM
2018-03-01
In vivo monitoring of 131I in human thyroid is often used to evaluate occupational exposure in nuclear medicine facilities and in the case of accidental intakes in nuclear power plants for the monitoring of workers and population. The device presented in this work consists on a Pb-collimated NaI(Tl)3”x3” scintillation detector assembled on a tripod and connected to a portable PC. The evaluation of the applicability and limitations of the system is based on the estimation of the committed effective doses associated to the minimum detectable activities in different facilities. It has been demonstrated that the system is suitable for use in routine and accidental situations.
NASA Astrophysics Data System (ADS)
Wang, Hongrui; Wang, Yupeng; Ye, Xin; Yang, Dongjun; Wang, Kai; Li, Huiduan; Fang, Wei
2017-01-01
The Total Solar Irradiance Monitor (TSIM) onboard the nadir Feng Yun-3C (FY-3C) satellite provides measurements of the total solar irradiance with accurate solar tracking and sound thermal stability of its heat sink. TSIM/FY-3C mainly consists of the pointing system, the radiometer package, the thermal control system, and the electronics. Accurate solar tracking is achieved by the pointing system, which greatly improves the science data quality when compared with the previous TSIM/FY-3A and TSIM/FY-3B. The total solar irradiance (TSI) is recorded by TSIM/FY-3C about 26 times each day, using a two-channel radiometer package. One channel is used to perform routine observation, and the other channel is used to monitor the degradation of the cavity detector in the routine channel. From the results of the ground test, the incoming irradiance is measured by the routine channel (AR1) with a relative uncertainty of 592 ppm. A general description of the TSIM, including the instrument modules, uncertainty evaluation, and its operation, is given in this article.
Improved Real-Time Monitoring Using Multiple Expert Systems
NASA Technical Reports Server (NTRS)
Schwuttke, Ursula M.; Angelino, Robert; Quan, Alan G.; Veregge, John; Childs, Cynthia
1993-01-01
Monitor/Analyzer of Real-Time Voyager Engineering Link (MARVEL) computer program implements combination of techniques of both conventional automation and artificial intelligence to improve monitoring of complicated engineering system. Designed to support ground-based operations of Voyager spacecraft, also adapted to other systems. Enables more-accurate monitoring and analysis of telemetry, enhances productivity of monitoring personnel, reduces required number of such personnel by performing routine monitoring tasks, and helps ensure consistency in face of turnover of personnel. Programmed in C language and includes commercial expert-system software shell also written in C.
This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...
This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...
This report covers the routine radiation monitoring activities conducted by the Environmental Monitoring Systems Laboratory-Las Vegas in areas which may be affected by nuclear testing programs of the Department of Energy. This monitoring is conducted to document compliance with s...
Hellmund, Richard; Weitgasser, Raimund; Blissett, Deirdre
2018-04-01
To estimate the costs associated with a flash glucose monitoring system as a replacement for routine self-monitoring of blood glucose (SMBG) in patients with type 1 diabetes mellitus (T1DM) using intensive insulin, from a UK National Health Service (NHS) perspective. The base-case cost calculation was created using the maximum frequency of glucose monitoring recommended by the 2015 National Institute for Health and Care Excellence guidelines (4-10 tests per day). Scenario analyses considered SMBG at the frequency observed in the IMPACT clinical trial (5.6 tests per day) and at the frequency of flash monitoring observed in a real-world analysis (16 tests per day). A further scenario included potential costs associated with severe hypoglycaemia. In the base case, the annual cost per patient using flash monitoring was £234 (19%) lower compared with routine SMBG (10 tests per day). In scenario analyses, the annual cost per patient of flash monitoring compared with 5.6 and 16 SMBG tests per day was £296 higher and £957 lower, respectively. The annual cost of severe hypoglycaemia for flash monitoring users was estimated to be £221 per patient, compared with £428 for routine SMBG users (based on 5.6 tests/day), corresponding to a reduction in costs of £207. The flash monitoring system has a modest impact on glucose monitoring costs for the UK NHS for patients with T1DM using intensive insulin. For people requiring frequent tests, flash monitoring may be cost saving, especially when taking into account potential reductions in the rate of severe hypoglycaemia. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Ludwig, Kimberly; Mackin, Michael; Wright, Theodore
1991-01-01
The authors describe the Ada language software developed to perform the electrical power system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electric power system to be used in Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 386/20e computers connected through an 802.4 local area network. The power system monitor algorithm comprises several functions, including periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data are collected from the switchgear sensors every 100 ms, then passed through a 2-Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The system monitor required a hardware timer interrupt to activate the data acquisition function. The execution time of the code was optimized by using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities.
A Distributed Prognostic Health Management Architecture
NASA Technical Reports Server (NTRS)
Bhaskar, Saha; Saha, Sankalita; Goebel, Kai
2009-01-01
This paper introduces a generic distributed prognostic health management (PHM) architecture with specific application to the electrical power systems domain. Current state-of-the-art PHM systems are mostly centralized in nature, where all the processing is reliant on a single processor. This can lead to loss of functionality in case of a crash of the central processor or monitor. Furthermore, with increases in the volume of sensor data as well as the complexity of algorithms, traditional centralized systems become unsuitable for successful deployment, and efficient distributed architectures are required. A distributed architecture though, is not effective unless there is an algorithmic framework to take advantage of its unique abilities. The health management paradigm envisaged here incorporates a heterogeneous set of system components monitored by a varied suite of sensors and a particle filtering (PF) framework that has the power and the flexibility to adapt to the different diagnostic and prognostic needs. Both the diagnostic and prognostic tasks are formulated as a particle filtering problem in order to explicitly represent and manage uncertainties; however, typically the complexity of the prognostic routine is higher than the computational power of one computational element ( CE). Individual CEs run diagnostic routines until the system variable being monitored crosses beyond a nominal threshold, upon which it coordinates with other networked CEs to run the prognostic routine in a distributed fashion. Implementation results from a network of distributed embedded devices monitoring a prototypical aircraft electrical power system are presented, where the CEs are Sun Microsystems Small Programmable Object Technology (SPOT) devices.
Arpadi, Stephen M; Shiau, Stephanie; De Gusmao, Eduarda Pimentel; Violari, Avy
2017-11-01
The objective of this commentary is to review considerations for implementing routine viral load (VL) monitoring programmes for HIV-infected infants and children living in low- and middle-income countries (LMIC). Since 2013, the World Health Organization (WHO) guidelines recommend VL testing as the preferred monitoring approach for all individuals treated with ART in order to assess treatment response, detect treatment failure and determine the need to switch to a second-line regimen in a timely manner. More recently, WHO guidelines from 2016 identify HIV-infected infants and children as a priority group for routine VL monitoring. There are a number of reasons why HIV-infected infants and children should be prioritized for routine VL monitoring. Data from national VL monitoring programmes as well as systematic reviews and meta-analyses from LMIC indicate rates of viral suppression are lower for infants and children compared to adults. The number of antiretroviral drugs and palatable formulations suitable for young children are limited. In addition, emotional and developmental issues particular to children can make daily medication administration difficult and pose a challenge to adherence and achievement of sustained viral suppression. VL monitoring can be instrumental for identifying those in need of additional adherence support, reducing regimen switches and preserving treatment options. The needs of infants and children warrant consideration in all aspects of VL monitoring services. If capacity for paediatric venipuncture is not assured, platforms that accept dried blood spot specimens are necessary in order for infants and children to have equitable access. Healthcare systems also need to prepare to manage the substantial number of infants and children identified with elevated VL, including adherence interventions that are appropriate for children. Establishing robust systems to evaluate processes and outcomes of routine VL monitoring services and to support drug forecasting and supply management is essential to determine best practices for infants and children in LMIC. The particular concerns of HIV-infected infants and children warrant attention during all phases of planning and implementation of VL monitoring services. There are a number of key areas, including frequency of monitoring, blood specimen type and adherence challenges, where specific approaches tailored for infants and children may be required. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.
NASA JSC water monitor system: City of Houston field demonstration
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.
1979-01-01
A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.
2010-01-01
Background The success of the Global Polio Eradication Initiative was remarkable, but four countries - Afghanistan, Pakistan, India and Nigeria - never interrupted polio transmission. Pakistan reportedly achieved all milestones except interrupting virus transmission. The aim of the study was to establish valid and reliable estimate for: routine oral polio vaccine (OPV) coverage, logistics management and the quality of monitoring systems in health facilities, NIDs OPV coverage, the quality of NIDs service delivery in static centers and mobile teams, and to ultimately provide scientific evidence for tailoring future interventions. Methods A cross-sectional study using lot quality assessment sampling was conducted in the District Nankana Sahib of Pakistan's Punjab province. Twenty primary health centers and their catchment areas were selected randomly as 'lots'. The study involved the evaluation of 1080 children aged 12-23 months for routine OPV coverage, 20 health centers for logistics management and quality of monitoring systems, 420 households for NIDs OPV coverage, 20 static centers and 20 mobile teams for quality of NIDs service delivery. Study instruments were designed according to WHO guidelines. Results Five out of twenty lots were rejected for unacceptably low routine immunization coverage. The validity of coverage was questionable to extent that all lots were rejected. Among the 54.1% who were able to present immunization cards, only 74.0% had valid immunization. Routine coverage was significantly associated with card availability and socioeconomic factors. The main reasons for routine immunization failure were absence of a vaccinator and unawareness of need for immunization. Health workers (96.9%) were a major source of information. All of the 20 lots were rejected for poor compliance in logistics management and quality of monitoring systems. Mean compliance score and compliance percentage for logistics management were 5.4 ± 2.0 (scale 0-9) and 59.4% while those for quality of monitoring systems were 3.3 ± 1.2 (scale 0-6) and 54.2%. The 15 out of 20 lots were rejected for unacceptably low NIDs coverage by finger-mark. All of the 20 lots were rejected for poor NIDs service delivery (mean compliance score = 11.7 ± 2.1 [scale 0-16]; compliance percentage = 72.8%). Conclusion Low coverage, both routine and during NIDs, and poor quality of logistics management, monitoring systems and NIDs service delivery were highlighted as major constraints in polio eradication and these should be considered in prioritizing future strategies. PMID:20144212
Mushtaq, Muhammad Umair; Majrooh, Muhammad Ashraf; Ullah, Mohsin Zia Sana; Akram, Javed; Siddiqui, Arif Mahmood; Shad, Mushtaq Ahmad; Waqas, Muhammad; Abdullah, Hussain Muhammad; Ahmad, Waqar; Shahid, Ubeera; Khurshid, Usman
2010-02-09
The success of the Global Polio Eradication Initiative was remarkable, but four countries - Afghanistan, Pakistan, India and Nigeria - never interrupted polio transmission. Pakistan reportedly achieved all milestones except interrupting virus transmission. The aim of the study was to establish valid and reliable estimate for: routine oral polio vaccine (OPV) coverage, logistics management and the quality of monitoring systems in health facilities, NIDs OPV coverage, the quality of NIDs service delivery in static centers and mobile teams, and to ultimately provide scientific evidence for tailoring future interventions. A cross-sectional study using lot quality assessment sampling was conducted in the District Nankana Sahib of Pakistan's Punjab province. Twenty primary health centers and their catchment areas were selected randomly as 'lots'. The study involved the evaluation of 1080 children aged 12-23 months for routine OPV coverage, 20 health centers for logistics management and quality of monitoring systems, 420 households for NIDs OPV coverage, 20 static centers and 20 mobile teams for quality of NIDs service delivery. Study instruments were designed according to WHO guidelines. Five out of twenty lots were rejected for unacceptably low routine immunization coverage. The validity of coverage was questionable to extent that all lots were rejected. Among the 54.1% who were able to present immunization cards, only 74.0% had valid immunization. Routine coverage was significantly associated with card availability and socioeconomic factors. The main reasons for routine immunization failure were absence of a vaccinator and unawareness of need for immunization. Health workers (96.9%) were a major source of information. All of the 20 lots were rejected for poor compliance in logistics management and quality of monitoring systems. Mean compliance score and compliance percentage for logistics management were 5.4 +/- 2.0 (scale 0-9) and 59.4% while those for quality of monitoring systems were 3.3 +/- 1.2 (scale 0-6) and 54.2%. The 15 out of 20 lots were rejected for unacceptably low NIDs coverage by finger-mark. All of the 20 lots were rejected for poor NIDs service delivery (mean compliance score = 11.7 +/- 2.1 [scale 0-16]; compliance percentage = 72.8%). Low coverage, both routine and during NIDs, and poor quality of logistics management, monitoring systems and NIDs service delivery were highlighted as major constraints in polio eradication and these should be considered in prioritizing future strategies.
FEMOS - Advanced Neutron Monitor System for Waste Management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simon, G.G.; Sokcic-Kostic, M.
2006-07-01
FEMOS is a specially developed monitor to detect fissile materials for waste characterisation and it is also suitable to identify the main neutron emitters. The latest measuring prototype is in routine operation at FZK-HDB (Germany) for determining Plutonium content and alpha activity in 2001 and 4001 drums from the reprocessing plant Karlsruhe (WAK). Authorities license the measurement procedure. Routine measurements conducted over a period of about 6 years and the results show that all specified prerequisites are met with the required reliability. (authors)
Kashima, Saori; Yorifuji, Takashi; Sawada, Norie; Nakaya, Tomoki; Eboshida, Akira
2018-08-01
Typically, land use regression (LUR) models have been developed using campaign monitoring data rather than routine monitoring data. However, the latter have advantages such as low cost and long-term coverage. Based on the idea that LUR models representing regional differences in air pollution and regional road structures are optimal, the objective of this study was to evaluate the validity of LUR models for nitrogen dioxide (NO 2 ) based on routine and campaign monitoring data obtained from an urban area. We selected the city of Suita in Osaka (Japan). We built a model based on routine monitoring data obtained from all sites (routine-LUR-All), and a model based on campaign monitoring data (campaign-LUR) within the city. Models based on routine monitoring data obtained from background sites (routine-LUR-BS) and based on data obtained from roadside sites (routine-LUR-RS) were also built. The routine LUR models were based on monitoring networks across two prefectures (i.e., Osaka and Hyogo prefectures). We calculated the predictability of the each model. We then compared the predicted NO 2 concentrations from each model with measured annual average NO 2 concentrations from evaluation sites. The routine-LUR-All and routine-LUR-BS models both predicted NO 2 concentrations well: adjusted R 2 =0.68 and 0.76, respectively, and root mean square error=3.4 and 2.1ppb, respectively. The predictions from the routine-LUR-All model were highly correlated with the measured NO 2 concentrations at evaluation sites. Although the predicted NO 2 concentrations from each model were correlated, the LUR models based on routine networks, and particularly those based on all monitoring sites, provided better visual representations of the local road conditions in the city. The present study demonstrated that LUR models based on routine data could estimate local traffic-related air pollution in an urban area. The importance and usefulness of data from routine monitoring networks should be acknowledged. Copyright © 2018 Elsevier B.V. All rights reserved.
Skeie, Marit S; Klock, Kristin S
2014-04-30
Recording reliable oral health data is a challenge. The aims were a) to outline different Scandinavian systems of oral health monitoring, b) to evaluate the quality and utility of the collected data in the light of modern concepts of disease management and to suggest improvements. The information for in this study was related to (a) children and adolescents, (b) oral health data and (c) routines for monitoring such data. This meant information available in the official web sites of the "KOSTRA-data" (Municipality-State-Report) in Norway, the Swedish National Board of Health and Welfare ("Socialstyrelsen") and Oral Health Register (the SCOR system, National Board of Health) in Denmark. A potential for increasing the reliability and validity of the data existed. Routines for monitoring other oral diseases than caries were limited. Compared with the other Scandinavian countries, the data collection system in Denmark appeared more functional and had adopted more modern concepts of disease management than other systems. In the light of modern concepts of caries management, data collected elsewhere had limited utility. The Scandinavian systems of health reporting had much in common, but some essential differences existed. If the quality of epidemiological data were enhanced, it would be possible to use the data for planning oral health care. Routines and procedures should be improved and updated in accordance with the modern ideas about caries prevention and therapy. For appropriate oral health planning in an organised dental service, reporting of enamel caries is essential.
Taylor, Sally; Allsop, Matthew J; Bekker, Hilary L; Bennett, Michael I; Bewick, Bridgette M
2017-07-01
Poor pain assessment is a barrier to effective pain control. There is growing interest internationally in the development and implementation of remote monitoring technologies to enhance assessment in cancer and chronic disease contexts. Findings describe the development and testing of pain monitoring systems, but research identifying the needs of health professionals to implement routine monitoring systems within clinical practice is limited. To inform the development and implementation strategy of an electronic pain monitoring system, PainCheck, by understanding palliative care professionals' needs when integrating PainCheck into routine clinical practice. Qualitative study using face-to-face interviews. Data were analysed using framework analysis Setting/participants: Purposive sample of health professionals managing the palliative care of patients living in the community Results: A total of 15 interviews with health professionals took place. Three meta-themes emerged from the data: (1) uncertainties about integration of PainCheck and changes to current practice, (2) appraisal of current practice and (3) pain management is everybody's responsibility Conclusion: Even the most sceptical of health professionals could see the potential benefits of implementing an electronic patient-reported pain monitoring system. Health professionals have reservations about how PainCheck would work in practice. For optimal use, PainCheck needs embedding within existing electronic health records. Electronic pain monitoring systems have the potential to enable professionals to support patients' pain management more effectively but only when barriers to implementation are appropriately identified and addressed.
2014-01-01
Background Recording reliable oral health data is a challenge. The aims were a) to outline different Scandinavian systems of oral health monitoring, b) to evaluate the quality and utility of the collected data in the light of modern concepts of disease management and to suggest improvements. Material and methods The information for in this study was related to (a) children and adolescents, (b) oral health data and (c) routines for monitoring such data. This meant information available in the official web sites of the “KOSTRA-data” (Municipality-State-Report) in Norway, the Swedish National Board of Health and Welfare (“Socialstyrelsen”) and Oral Health Register (the SCOR system, National Board of Health) in Denmark. Results A potential for increasing the reliability and validity of the data existed. Routines for monitoring other oral diseases than caries were limited. Compared with the other Scandinavian countries, the data collection system in Denmark appeared more functional and had adopted more modern concepts of disease management than other systems. In the light of modern concepts of caries management, data collected elsewhere had limited utility. Conclusions The Scandinavian systems of health reporting had much in common, but some essential differences existed. If the quality of epidemiological data were enhanced, it would be possible to use the data for planning oral health care. Routines and procedures should be improved and updated in accordance with the modern ideas about caries prevention and therapy. For appropriate oral health planning in an organised dental service, reporting of enamel caries is essential. PMID:24885243
a Study on Satellite Diagnostic Expert Systems Using Case-Based Approach
NASA Astrophysics Data System (ADS)
Park, Young-Tack; Kim, Jae-Hoon; Park, Hyun-Soo
1997-06-01
Many research works are on going to monitor and diagnose diverse malfunctions of satellite systems as the complexity and number of satellites increase. Currently, many works on monitoring and diagnosis are carried out by human experts but there are needs to automate much of the routine works of them. Hence, it is necessary to study on using expert systems which can assist human experts routine work by doing automatically, thereby allow human experts devote their expertise more critical and important areas of monitoring and diagnosis. In this paper, we are employing artificial intelligence techniques to model human experts' knowledge and inference the constructed knowledge. Especially, case-based approaches are used to construct a knowledge base to model human expert capabilities which use previous typical exemplars. We have designed and implemented a prototype case-based system for diagnosing satellite malfunctions using cases. Our system remembers typical failure cases and diagnoses a current malfunction by indexing the case base. Diverse methods are used to build a more user friendly interface which allows human experts can build a knowledge base in as easy way.
Documentation of the data analysis system for the gamma ray monitor aboard OSO-H
NASA Technical Reports Server (NTRS)
Croteau, S.; Buck, A.; Higbie, P.; Kantauskis, J.; Foss, S.; Chupp, D.; Forrest, D. J.; Suri, A.; Gleske, I.
1973-01-01
The programming system is presented which was developed to prepare the data from the gamma ray monitor on OSO-7 for scientific analysis. The detector, data, and objectives are described in detail. Programs presented include; FEEDER, PASS-1, CAL1, CAL2, PASS-3, Van Allen Belt Predict Program, Computation Center Plot Routine, and Response Function Programs.
Opportunities for improving the efficiency of paediatric HIV treatment programmes
Revill, Paul A.; Walker, Simon; Mabugu, Travor; Nathoo, Kusum J.; Mugyenyi, Peter; Kekitinwa, Adeodata; Munderi, Paula; Bwakura-Dangarembizi, Mutsawashe; Musiime, Victor; Bakeera-Kitaka, Sabrina; Nahirya-Ntege, Patricia; Walker, A. Sarah; Sculpher, Mark J.; Gibb, Diana M.
2015-01-01
Objectives: To conduct two economic analyses addressing whether to: routinely monitor HIV-infected children on antiretroviral therapy (ART) clinically or with laboratory tests; continue or stop cotrimoxazole prophylaxis when children become stabilized on ART. Design and methods: The ARROW randomized trial investigated alternative strategies to deliver paediatric ART and cotrimoxazole prophylaxis in 1206 Ugandan/Zimbabwean children. Incremental cost-effectiveness and value of implementation analyses were undertaken. Scenario analyses investigated whether laboratory monitoring (CD4+ tests for efficacy monitoring; haematology/biochemistry for toxicity) could be tailored and targeted to be delivered cost-effectively. Cotrimoxazole use was examined in malaria-endemic and non-endemic settings. Results: Using all trial data, clinical monitoring delivered similar health outcomes to routine laboratory monitoring, but at a reduced cost, so was cost-effective. Continuing cotrimoxazole improved health outcomes at reduced costs. Restricting routine CD4+ monitoring to after 52 weeks following ART initiation and removing toxicity testing was associated with an incremental cost-effectiveness ratio of $6084 per quality-adjusted life-year (QALY) across all age groups, but was much lower for older children (12+ years at initiation; incremental cost-effectiveness ratio = $769/QALY). Committing resources to improve cotrimoxazole implementation appears cost-effective. A healthcare system that could pay $600/QALY should be willing to spend up to $12.0 per patient-year to ensure continued provision of cotrimoxazole. Conclusion: Clinically driven monitoring of ART is cost-effective in most circumstances. Routine laboratory monitoring is generally not cost-effective at current prices, except possibly CD4+ testing amongst adolescents initiating ART. Committing resources to ensure continued provision of cotrimoxazole in health facilities is more likely to represent an efficient use of resources. PMID:25396263
Drought monitoring: Historical and current perspectives
USDA-ARS?s Scientific Manuscript database
Given the complex dimensions of drought and the challenges they pose for routine drought monitoring, it is essential that we continue to find innovative and robust ways to quantify and more effectively communicate the impacts of this hazard as part of an operational Drought Early Warning System. Th...
NASA Technical Reports Server (NTRS)
Ludwig, Kimberly; Mackin, Michael; Wright, Theodore
1991-01-01
The Ada language software development to perform the electrical system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed is described. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electrical power system to be used in the Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 382/20e computers connected through an 802.4 local area network. One of these computers is designated as the control node with the other four acting as subsidiary controllers. The subsidiary controllers are connected to the power control components with a Mil-Std-1553 network. An operator interface is supplied by adding a sixth computer. The power system monitor algorithm is comprised of several functions including: periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data is collected from the switchgear sensors every 100 milliseconds, then passed through a 2 Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The reporting mechanism notifies an operator of any abnormalities in the system. Once per second, the system monitor provides data to the control node for further processing, such as state estimation. The system monitor required a hardware time interrupt to activate the data acquisition function. The execution time of the code was optimized using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities. A summary of the advantages and side effects of this technique are discussed.
Apparatus, system, and method for synchronizing a timer key
Condit, Reston A; Daniels, Michael A; Clemens, Gregory P; Tomberlin, Eric S; Johnson, Joel A
2014-04-22
A timer key relating to monitoring a countdown time of a countdown routine of an electronic device is disclosed. The timer key comprises a processor configured to respond to a countdown time associated with operation of the electronic device, a display operably coupled with the processor, and a housing configured to house at least the processor. The housing has an associated structure configured to engage with the electronic device to share the countdown time between the electronic device and the timer key. The processor is configured to begin a countdown routine based at least in part on the countdown time, wherein the countdown routine is at least substantially synchronized with a countdown routine of the electronic device when the timer key is removed from the electronic device. A system and method for synchronizing countdown routines of a timer key and an electronic device are also disclosed.
What evidence do we have to replace in-hospital implantable cardioverter defibrillator follow-up?
Brugada, P
2006-01-01
Due to the increasing number of patients with an implantable cardioverter defibrillator (ICD), new options for ICD patient follow-up management are required. Patients with ICD indication according to the guidelines received an ICD with Home Monitoring technology. The devices enabled the transmission of the relevant episode, therapy, and system integrity data. Patients were followed for 12 months with routine controls every 3 months. The physician analyzed the Home Monitoring data before the routine follow-up visit (FU) and gave a forecast on the necessity of the pending FU, which was compared with the evaluation after the FU. Based on the derived forecast reliability, a patient management scheme was developed and its impact on patient safety was assessed retrospectively. A total of 271 patients were enrolled (40 f, mean age 62+/-12 years, mean LVEF 39+/-15%, 65% ischemic heart disease, 20% cardiomyopathy) and followed for 339+/-109 days. Of 908 pairs of Home Monitoring data and FU data evaluation, 129 there were false negative results for 92 patients. Safety concerns from false negative forecasts can be minimized with a patient management scheme containing the following elements: 1) never skip the first routine FU; 2) never skip a routine FU for a patient having already shown pacing threshold problems; 3) perform FU following hospitalizations; 4) perform FU following episode detection by the ICD; and 5) perform a routine FU if the patient reports symptoms. The retrospective analysis showed, that if the patients had been managed using this scheme, 503 of 1079 routine FU could have been skipped with only one safety concern, a three month delay in the detection of silent paroxysmal atrial fibrillation in one patient. Home Monitoring in ICD therapy over 12 months is feasible. The data transmitted relevantly contribute to a remarkable reduction of follow-up burden and enable the individualization of routine follow-up.
40 CFR 141.621 - Routine monitoring.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 141.621 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Stage 2 Disinfection Byproducts Requirements § 141... small system waiver under § 141.604 or you are a nontransient noncommunity water system serving <10,000...
IMS Version 3 Student Data Base Maintenance Program.
ERIC Educational Resources Information Center
Brown, John R.
Computer routines that update the Instructional Management System (IMS) Version 3 student data base which supports the Southwest Regional Laboratory's (SWRL) student monitoring system are described. Written in IBM System 360 FORTRAN IV, the program updates the data base by adding, changing and deleting records, as well as adding and deleting…
Barreix, Maria; Tunçalp, Özge; Mutombo, Namuunda; Adegboyega, Ayotunde A; Say, Lale
2017-05-01
Universal access to sexual and reproductive health remains part of the unfinished business of global development in Africa. To achieve it, health interventions should be monitored using programmatic indicators. WHO's Strengthening Measurement of Reproductive Health Indicators in Africa initiative, implemented in Ghana, Nigeria, Kenya, Uganda, and Zimbabwe, aimed to improve national information systems for routine monitoring of reproductive health indicators. Participating countries developed action plans employing a two-pronged strategy: (1) revising, standardizing, and harmonizing existing reproductive health indicators captured through routine information-systems; and (2) building data-collection capacity through training and supervision at select pilot sites. Country teams evaluated existing and new indicators, and outlined barriers to strengthening routine measurement. Activities included updating abortion-care guidelines (spontaneous and induced abortions), providing training on laws surrounding induced abortions, and improving feedback mechanisms. The country teams updated monitoring and evaluation frameworks, and attempted to build recording/reporting capacity in selected pilot areas. Barriers to implementing the initiative that were encountered included restrictive induced-abortion laws, staff turn-over, and administrative delays, including low capacity among healthcare staff and competing priorities for staff time. The areas identified for further improvement were up-scaling programs to a national level, creating scorecards to record data, increasing collaborations with the private sector, conducting related costing exercises, and performing ex-post evaluations. © 2017 World Health Organization; licensed by Wiley on behalf of International Federation of Gynecology and Obstetrics.
Hailey, P A; Doherty, P; Tapsell, P; Oliver, T; Aldridge, P K
1996-03-01
An automated system for the on-line monitoring of powder blending processes is described. The system employs near-infrared (NIR) spectroscopy using fibre-optics and a graphical user interface (GUI) developed in the LabVIEW environment. The complete supervisory control and data analysis (SCADA) software controls blender and spectrophotometer operation and performs statistical spectral data analysis in real time. A data analysis routine using standard deviation is described to demonstrate an approach to the real-time determination of blend homogeneity.
Massin, Frédéric; Huili, Cai; Decot, Véronique; Stoltz, Jean-François; Bensoussan, Danièle; Latger-Cannard, Véronique
2015-01-01
Stem cells for autologous and allogenic transplantation are obtained from several sources including bone marrow, peripheral blood or cord blood. Accurate enumeration of viable CD34+ hematopoietic stem cells (HSC) is routinely used in clinical settings, especially to monitor progenitor cell mobilization and apheresis. The number of viable CD34+ HSC has also been shown to be the most critical factor in haematopoietic engraftment. The International Society for Cellular Therapy actually recommends the use of single-platform flow cytometry system using 7-AAD as a viability dye. In a way to move routine analysis from a BD FACSCaliburTM instrument to a BD FACSCantoTM II, according to ISO 15189 standard guidelines, we define laboratory performance data of the BDTM Stem Cell Enumeration (SCE) kit on a CE-IVD system including a BD FACSCanto II flow cytometer and the BD FACSCantoTM Clinical Software. InterQCTM software, a real time internet laboratory QC management system developed by VitroTM and distributed by Becton DickinsonTM, was also tested to monitor daily QC data, to define the internal laboratory statistics and to compare them to external laboratories. Precision was evaluated with BDTM Stem Cell Control (high and low) results and the InterQC software, an internet laboratory QC management system by Vitro. This last one drew Levey-Jennings curves and generated numeral statistical parameters allowing detection of potential changes in the system performances as well as interlaboratory comparisons. Repeatability, linearity and lower limits of detection were obtained with routine samples from different origins. Agreement evaluation between BD FACSCanto II system versus BD FACSCalibur system was tested on fresh peripheral blood, freeze-thawed apheresis, fresh bone marrow and fresh cord blood samples. Instrument's measure and staining repeatability clearly evidenced acceptable variability on the different samples tested. Intra- and inter-laboratory CV in CD34+ cell absolute count are consistent and reproducible. Linearity analysis, established between 2 and 329 cells/μl showed a linear relation between expected counts and measured counts (R2=0.97). Linear regression and Bland-Altman representations showed an excellent correlation on samples from different sources between the two systems and allowed the transfer of routine analysis from BD FACSCalibur to BD FACSCanto II. The BD SCE kit provides an accurate measure of the CD34 HSC, and can be used in daily routine to optimize the enumeration of hematopoietic CD34+ stem cells by flow cytometry. Moreover, the InterQC system seems to be a very useful tool for laboratory daily quality monitoring and thus for accreditation.
Use of Continuous Integration Tools for Application Performance Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vergara Larrea, Veronica G; Joubert, Wayne; Fuson, Christopher B
High performance computing systems are becom- ing increasingly complex, both in node architecture and in the multiple layers of software stack required to compile and run applications. As a consequence, the likelihood is increasing for application performance regressions to occur as a result of routine upgrades of system software components which interact in complex ways. The purpose of this study is to evaluate the effectiveness of continuous integration tools for application performance monitoring on HPC systems. In addition, this paper also describes a prototype system for application perfor- mance monitoring based on Jenkins, a Java-based continuous integration tool. The monitoringmore » system described leverages several features in Jenkins to track application performance results over time. Preliminary results and lessons learned from monitoring applications on Cray systems at the Oak Ridge Leadership Computing Facility are presented.« less
Averinova, S G; Kashkadaeva, A V; Shiriaev, S V; Nechipaĭ, A M; Dmitrieva, G D
1999-01-01
The paper deals with a diagnostic informational and analytical system (DIAS). The system is based on the current concept of a dynamic model of nephro-urological clearance macroregulation under retention factors at the pre-, intra-, and postrenal levels during drug load tests. DIAS includes a package of dynamic renoscintigraphic techniques, as well as original software support. A system for parameters of renal clearance regulation has been developed, which is effective at nephro-urological screening and monitoring at all treatment stages for cancer patients. A two-detector chamber which permits the mounting of a detector at an angle to the patient's body is the optimum diagnostic apparatus for a cancer clinic. The use of functional tests makes it possible to examine the regulatory reserves for each kidney, followed up by the choice of adequate corrective measures to prevent renal failure during treatment. In some cases, DIAS monitoring frequently shows a higher sensitivity to the signs of latent renal failure than does routine clinical and laboratory monitoring. The effective radiation dose taken by a patient during a study by the DIAS technology aimed at reducing radioopaque doses is 100-150 times higher than that at an X-ray study and is an order less than during routine urinary tests.
1982-06-01
start/stop chiller optimization , and demand limiting were added. The system monitors a 7,000 ton chiller plant and controls 74 air handlers. The EMCS does...Modify analog limits. g. Adjust setpoints of selected controllers. h. Select manual or automatic control modes. i. Enable and disable individual points...or event schedules and controller setpoints ; make nonscheduled starts and stops of equipment or disable field panels when required for routine
A Behaviour Monitoring System (BMS) for Ambient Assisted Living
Eisa, Samih
2017-01-01
Unusual changes in the regular daily mobility routine of an elderly person at home can be an indicator or early symptom of developing health problems. Sensor technology can be utilised to complement the traditional healthcare systems to gain a more detailed view of the daily mobility of a person at home when performing everyday tasks. We hypothesise that data collected from low-cost sensors such as presence and occupancy sensors can be analysed to provide insights on the daily mobility habits of the elderly living alone at home and to detect routine changes. We validate this hypothesis by designing a system that automatically learns the daily room-to-room transitions and permanence habits in each room at each time of the day and generates alarm notifications when deviations are detected. We present an algorithm to process the sensors’ data streams and compute sensor-driven features that describe the daily mobility routine of the elderly as part of the developed Behaviour Monitoring System (BMS). We are able to achieve low detection delay with confirmation time that is high enough to convey the detection of a set of common abnormal situations. We illustrate and evaluate BMS with synthetic data, generated by a developed data generator that was designed to mimic different user’s mobility profiles at home, and also with a real-life dataset collected from prior research work. Results indicate BMS detects several mobility changes that can be symptoms of common health problems. The proposed system is a useful approach for learning the mobility habits at the home environment, with the potential to detect behaviour changes that occur due to health problems, and therefore, motivating progress toward behaviour monitoring and elder’s care. PMID:28837105
Guyon, Agnes; Bock, Ariella; Buback, Laura; Knittel, Barbara
2016-12-23
Implementing complex nutrition and other public health projects and tracking nutrition interventions, such as women's diet and supplementation and infant and young child feeding practices, requires reliable routine data to identify potential program gaps and to monitor trends in behaviors in real time. However, current monitoring and evaluation practices generally do not create an environment for this real-time tracking. This article describes the development and application of a mobile-based nutrition and health monitoring system, which collected monitoring data on project activities, women's nutrition, and infant and young child feeding practices in real time. The Liberia Agricultural Upgrading Nutrition and Child Health (LAUNCH) project implemented a nutrition and health monitoring system between April 2012 and June 2014. The LAUNCH project analyzed project monitoring and outcome data from the system and shared selected behavioral and programmatic indicators with program managers through a short report, which later evolved into a visual data dashboard, during program-update meetings. The project designed protocols to ensure representativeness of program participants. LAUNCH made programmatic adjustments in response to findings from the monitoring system; these changes were then reflected in subsequent quarterly trends, indicating that the availability of timely data allowed for the project to react quickly to issues and adapt the program appropriately. Such issues included lack of participation in community groups and insufficient numbers of food distribution points. Likewise, the system captured trends in key outcome indicators such as breastfeeding and complementary feeding practices, linking them to project activities and external factors including seasonal changes and national health campaigns. Digital data collection platforms can play a vital role in improving routine programmatic functions. Fixed gathering locations such as food distribution points represent an opportunity to easily access program participants and enable managers to identify strengths and weaknesses in project implementation. For programs that track individuals over time, a mobile tool combined with a strong database can greatly improve efficiency and data visibility and reduce resource leakages. © Guyon et al.
1981-09-01
Change = 2311 (257) Teaching - Diabetic = 2313 (258) Labor Room Examination and Preparation, Routine = 2434 (259) Fetal Heart Tones, Manual = 2412 (260... Fetal Heart Tones, Doppler = 2413 (261) Dilatation and Effecement Assessment = 2403 (262) Dilatation and Effacement Assessment, Assisting Physician...Ultrasonic Transducer/Tocotransducer = 2435 (270) Monitoring Fetal Heart Tones, Ultrasonic Transducer = 2436 (271) Monitoring Fetal Heart Tones, Ultrasonic
Methods for synchronizing a countdown routine of a timer key and electronic device
Condit, Reston A.; Daniels, Michael A.; Clemens, Gregory P.; Tomberlin, Eric S.; Johnson, Joel A.
2015-06-02
A timer key relating to monitoring a countdown time of a countdown routine of an electronic device is disclosed. The timer key comprises a processor configured to respond to a countdown time associated with operation of the electronic device, a display operably coupled with the processor, and a housing configured to house at least the processor. The housing has an associated structure configured to engage with the electronic device to share the countdown time between the electronic device and the timer key. The processor is configured to begin a countdown routine based at least in part on the countdown time, wherein the countdown routine is at least substantially synchronized with a countdown routine of the electronic device when the timer key is removed from the electronic device. A system and method for synchronizing countdown routines of a timer key and an electronic device are also disclosed.
Real time computer data system for the 40 x 80 ft wind tunnel facility at Ames Research Center
NASA Technical Reports Server (NTRS)
Cambra, J. M.; Tolari, G. P.
1974-01-01
The wind tunnel realtime computer system is a distributed data gathering system that features a master computer subsystem, a high speed data gathering subsystem, a quick look dynamic analysis and vibration control subsystem, an analog recording back-up subsystem, a pulse code modulation (PCM) on-board subsystem, a communications subsystem, and a transducer excitation and calibration subsystem. The subsystems are married to the master computer through an executive software system and standard hardware and FORTRAN software interfaces. The executive software system has four basic software routines. These are the playback, setup, record, and monitor routines. The standard hardware interfaces along with the software interfaces provide the system with the capability of adapting to new environments.
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
40 CFR 57.402 - Elements of the supplementary control system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... capable of routine real time measurement of maximum expected SO2 concentrations for the averaging times of... emission curtailment decisions based on the use of real time information from the air quality monitoring... meteorological information necessary to operate the system; (iv) The ambient concentrations and meteorological...
Elliot, A J; Hughes, H E; Hughes, T C; Locker, T E; Brown, R; Sarran, C; Clewlow, Y; Murray, V; Bone, A; Catchpole, M; McCloskey, B; Smith, G E
2014-08-01
This study illustrates the potential of using emergency department attendance data, routinely accessed as part of a national syndromic surveillance system, to monitor the impact of thunderstorm asthma. The Emergency Department Syndromic Surveillance System (EDSSS) routinely monitors anonymised attendance data on a daily basis across a sentinel network of 35 emergency departments. Attendance data for asthma, wheeze and difficulty breathing are analysed on a daily basis. A statistically significant spike in asthma attendances in two EDSSS emergency departments in London was detected on 23 July 2013, coinciding with a series of large violent thunderstorms across southern England. There was also an increase in the reported severity of these attendances. This preliminary report illustrates the potential of the EDSSS to monitor the impact of thunderstorms on emergency department asthma attendances. Further work will focus on how this system can be used to quantify the impact on emergency departments, thus potentially improving resource planning and also adding to the thunderstorm asthma evidence-base. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
NASA Astrophysics Data System (ADS)
Swindell, Paul; Doyle, Jon; Roach, Dennis
2017-02-01
The Federal Aviation Administration (FAA) started a research program in structural health monitoring (SHM) in 2011. The program's goal was to understand the technical gaps of implementing SHM on commercial aircraft and the potential effects on FAA regulations and guidance. The program evolved into a demonstration program consisting of a team from Sandia National Labs Airworthiness Assurance NDI Center (AANC), the Boeing Corporation, Delta Air Lines, Structural Monitoring Systems (SMS), Anodyne Electronics Manufacturing Corp (AEM) and the FAA. This paper will discuss the program from the selection of the inspection problem, the SHM system (Comparative Vacuum Monitoring-CVM) that was selected as the inspection solution and the testing completed to provide sufficient data to gain the first approved use of an SHM system for routine maintenance on commercial US aircraft.
Design and operation of internal dosimetry programs
DOE Office of Scientific and Technical Information (OSTI.GOV)
LaBone, T.R.
1991-01-01
The proposed revision to USNRC 10 CFR 20 and the USDOE Order 5480.11 require intakes of radioactive material to be evaluated. Radiation dose limits are based on the sum of effective dose equivalent from intakes and the whole body dose from external sources. These significant changes in the regulations will require, at a minimum, a complete review of personnel monitoring programs to determine their adequacy. In this session we will review a systematic method of designing a routine personnel monitoring program that will comply with the requirements of the new regulations. Specific questions discussed are: (a) What are the goalsmore » and objectives of a routine personnel monitoring program (b) When is a routine personnel monitoring program required (c) What are the required capabilities of the routine personnel monitoring program (d) What should be done with the information generated in a personnel monitoring program Specific recommendations and interpretations are given in the session. 5 refs., 3 figs., 33 tabs.« less
Lucock, Mike; Halstead, Jeremy; Leach, Chris; Barkham, Michael; Tucker, Samantha; Randal, Chloe; Middleton, Joanne; Khan, Wajid; Catlow, Hannah; Waters, Emma; Saxon, David
2015-01-01
Abstract Objective: To investigate the barriers and facilitators of an effective implementation of an outcome monitoring and feedback system in a UK National Health Service psychological therapy service. Method: An outcome monitoring system was introduced in two services. Enhanced feedback was given to therapists after session 4. Qualitative and quantitative methods were used, including questionnaires for therapists and patients. Thematic analysis was carried out on written and verbal feedback from therapists. Analysis of patient outcomes for 202 episodes of therapy was compared with benchmark data of 136 episodes of therapy for which feedback was not given to therapists. Results: Themes influencing the feasibility and acceptability of the feedback system were the extent to which therapists integrated the measures and feedback into the therapy, availability of administrative support, information technology, and complexity of the service. There were low levels of therapist actions resulting from the feedback, including discussing the feedback in supervision and with patients. Conclusions: The findings support the feasibility and acceptability of setting up a routine system in a complex service, but a number of challenges and barriers have to be overcome and therapist differences are apparent. More research on implementation and effectiveness is needed in diverse clinical settings. PMID:26436605
Metagenomic applications in environmental monitoring and bioremediation.
Techtmann, Stephen M; Hazen, Terry C
2016-10-01
With the rapid advances in sequencing technology, the cost of sequencing has dramatically dropped and the scale of sequencing projects has increased accordingly. This has provided the opportunity for the routine use of sequencing techniques in the monitoring of environmental microbes. While metagenomic applications have been routinely applied to better understand the ecology and diversity of microbes, their use in environmental monitoring and bioremediation is increasingly common. In this review we seek to provide an overview of some of the metagenomic techniques used in environmental systems biology, addressing their application and limitation. We will also provide several recent examples of the application of metagenomics to bioremediation. We discuss examples where microbial communities have been used to predict the presence and extent of contamination, examples of how metagenomics can be used to characterize the process of natural attenuation by unculturable microbes, as well as examples detailing the use of metagenomics to understand the impact of biostimulation on microbial communities.
A Labor and Delivery Patient Classification System Based on Direct Nursing Care Time
1991-08-01
physician 2409 Internal or external monitoring--uterine contraction/ fetal heart tones 2410 Manual contraction assessment 2411 Pitocin induction...assisting physician 2412 Fetal heart tones, manual 2413 Fetal heart tones, doppler 2414 Fetal scalp sampling, assisting physician 241E Routine delivery room... heart tones, ultrasonic transducer 2437 Monitoring fetal heart tones, ultrasonic transducer and uterine contraction, tocotransducer 69 Appendix B: List
Implementation of medical monitor system based on networks
NASA Astrophysics Data System (ADS)
Yu, Hui; Cao, Yuzhen; Zhang, Lixin; Ding, Mingshi
2006-11-01
In this paper, the development trend of medical monitor system is analyzed and portable trend and network function become more and more popular among all kinds of medical monitor devices. The architecture of medical network monitor system solution is provided and design and implementation details of medical monitor terminal, monitor center software, distributed medical database and two kind of medical information terminal are especially discussed. Rabbit3000 system is used in medical monitor terminal to implement security administration of data transfer on network, human-machine interface, power management and DSP interface while DSP chip TMS5402 is used in signal analysis and data compression. Distributed medical database is designed for hospital center according to DICOM information model and HL7 standard. Pocket medical information terminal based on ARM9 embedded platform is also developed to interactive with center database on networks. Two kernels based on WINCE are customized and corresponding terminal software are developed for nurse's routine care and doctor's auxiliary diagnosis. Now invention patent of the monitor terminal is approved and manufacture and clinic test plans are scheduled. Applications for invention patent are also arranged for two medical information terminals.
Programming for energy monitoring/display system in multicolor lidar system research
NASA Technical Reports Server (NTRS)
Alvarado, R. C., Jr.; Allen, R. J.
1982-01-01
The Z80 microprocessor based computer program that directs and controls the operation of the six channel energy monitoring/display system that is a part of the NASA Multipurpose Airborne Differential Absorption Lidar (DIAL) system is described. The program is written in the Z80 assembly language and is located on EPROM memories. All source and assembled listings of the main program, five subroutines, and two service routines along with flow charts and memory maps are included. A combinational block diagram shows the interfacing (including port addresses) between the six power sensors, displays, front panel controls, the main general purpose minicomputer, and this dedicated microcomputer system.
75 FR 8171 - Privacy Act of 1974, as Amended; Proposed System of Records and Routine Use Disclosures
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-23
... applicable to this system of records entitled, the Administrative Law Judge/Public Alleged Misconduct... committed misconduct; and Provide us with management information to document, monitor, and track complaints..., and to assist us in deterring recurring incidences of ALJ bias or misconduct. B. Collection and...
Schneeweiss, S; Eichler, H-G; Garcia-Altes, A; Chinn, C; Eggimann, A-V; Garner, S; Goettsch, W; Lim, R; Löbker, W; Martin, D; Müller, T; Park, B J; Platt, R; Priddy, S; Ruhl, M; Spooner, A; Vannieuwenhuyse, B; Willke, R J
2016-12-01
Analyses of healthcare databases (claims, electronic health records [EHRs]) are useful supplements to clinical trials for generating evidence on the effectiveness, harm, use, and value of medical products in routine care. A constant stream of data from the routine operation of modern healthcare systems, which can be analyzed in rapid cycles, enables incremental evidence development to support accelerated and appropriate access to innovative medicines. Evidentiary needs by regulators, Health Technology Assessment, payers, clinicians, and patients after marketing authorization comprise (1) monitoring of medication performance in routine care, including the materialized effectiveness, harm, and value; (2) identifying new patient strata with added value or unacceptable harms; and (3) monitoring targeted utilization. Adaptive biomedical innovation (ABI) with rapid cycle database analytics is successfully enabled if evidence is meaningful, valid, expedited, and transparent. These principles will bring rigor and credibility to current efforts to increase research efficiency while upholding evidentiary standards required for effective decision-making in healthcare. © 2016 American Society for Clinical Pharmacology and Therapeutics.
Smets, G; Alcalde, E; Andres, D; Carron, D; Delzenne, P; Heise, A; Legris, G; Martinez Parrilla, M; Verhaert, J; Wandelt, C; Ilegems, M; Rüdelsheim, P
2014-07-01
The European Union (EU) Directive 2001/18/EC on the deliberate release of genetically modified organisms (GMOs) into the environment requires that both Case-Specific Monitoring (CSM) and General Surveillance (GS) are considered as post-market implementing measures. Whereas CSM is directed to monitor potential adverse effects of GMOs or their use identified in the environmental risk assessment, GS aims to detect un-intended adverse effects of GMOs or their use on human and animal health or the environment. Guidance documents on the monitoring of genetically modified (GM) plants from the Commission and EFSA clarify that, as appropriate, GS can make use of established routine surveillance practices. Networks involved in routine surveillance offer recognised expertise in a particular domain and are designed to collect information on important environmental aspects over a large geographical area. However, as the suitability of existing monitoring networks to provide relevant data for monitoring impacts of GMOs is not known, plant biotechnology companies developed an approach to describe the processes and criteria that will be used for selecting and evaluating existing monitoring systems. In this paper, the availability of existing monitoring networks for this purpose is evaluated. By cataloguing the existing environmental monitoring networks in the EU, it can be concluded that they can only be used, in the context of GMO cultivation monitoring, as secondary tools to collect baseline information.
Poy, Alain; van den Ent, Maya M V X; Sosler, Stephen; Hinman, Alan R; Brown, Sidney; Sodha, Samir; Ehlman, Daniel C; Wallace, Aaron S; Mihigo, Richard
2017-07-01
To monitor immunization-system strengthening in the Polio Eradication Endgame Strategic Plan 2013-2018 (PEESP), the Global Polio Eradication Initiative identified 1 indicator: 10% annual improvement in third dose of diphtheria- tetanus-pertussis-containing vaccine (DTP3) coverage in polio high-risk districts of 10 polio focus countries. A multiagency team, including staff from the African Region, developed a comprehensive list of outcome and process indicators measuring various aspects of the performance of an immunization system. The development and implementation of the dashboard to assess immunization system performance allowed national program managers to monitor the key immunization indicators and stratify by high-risk and non-high-risk districts. Although only a single outcome indicator goal (at least 10% annual increase in DTP3 coverage achieved in 80% of high-risk districts) initially existed in the endgame strategy, we successfully added additional outcome indicators (eg, decreasing the number of DTP3-unvaccinated children) as well as program process indicators focusing on cold chain, stock availability, and vaccination sessions to better describe progress on the pathway to raising immunization coverage. When measuring progress toward improving immunization systems, it is helpful to use a comprehensive approach that allows for measuring multiple dimensions of the system. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.
Alexander, John C; Minhajuddin, Abu; Joshi, Girish P
2017-08-01
Use of healthcare-related smartphone applications is common. However, there is concern that inaccurate information from these applications may lead patients to make erroneous healthcare decisions. The objective of this study is to study smartphone applications purporting to measure vital sign data using only onboard technology compared with monitors used routinely in clinical practice. This is a prospective trial comparing correlation between a clinically utilized vital sign monitor (Propaq CS, WelchAllyn, Skaneateles Falls, NY, USA) and four smartphone application-based monitors Instant Blood Pressure, Instant Blood Pressure Pro, Pulse Oximeter, and Pulse Oximeter Pro. We performed measurements of heart rate (HR), systolic blood pressures (SBP), diastolic blood pressure (DBP), and oxygen saturation (SpO 2 ) using standard monitor and four smartphone applications. Analysis of variance was used to compare measurements from the applications to the routine monitor. The study was completed on 100 healthy volunteers. Comparison of routine monitor with the smartphone applications shows significant differences in terms of HR, SpO 2 and DBP. The SBP values from the applications were not significantly different from those from the routine monitor, but had wide limits of agreement signifying a large degree of variation in the compared values. The degree of correlation between monitors routinely used in clinical practice and the smartphone-based applications studied is insufficient to recommend clinical utilization. This lack of correlation suggests that the applications evaluated do not provide clinically meaningful data. The inaccurate data provided by these applications can potentially contribute to patient harm.
Teaching Early Readers to Self-Monitor and Self-Correct
ERIC Educational Resources Information Center
Pratt, Sharon M.; Urbanowski, Melena
2016-01-01
Proficient readers self-monitor and self-correct to derive meaning from text. This article reviews research on how students learn to self-monitor and self-correct and describes a Reciprocal Teaching (RT) instructional routine that was successfully used with early readers to build their metacognitive processes. The RT routine included teacher…
Berberich, Gabriele; Berberich, Martin; Grumpe, Arne; Wöhler, Christian; Schreiber, Ulrich
2013-01-01
Simple Summary For three years (2009–2012), two red wood ant mounds (Formica rufa-group), located at the seismically active Neuwied Basin (Eifel, Germany), have been monitored 24/7 by high-resolution cameras. Early results show that ants have a well-identifiable standard daily routine. Correlation with local seismic events suggests changes in the ants’ behavior hours before the earthquake: the nocturnal rest phase and daily activity are suppressed, and standard daily routine does not resume until the next day. At present, an automated image evaluation routine is being applied to the video streams. Based on this automated approach, a statistical analysis of the ant behavior will be carried out. Abstract Short-term earthquake predictions with an advance warning of several hours or days are currently not possible due to both incomplete understanding of the complex tectonic processes and inadequate observations. Abnormal animal behaviors before earthquakes have been reported previously, but create problems in monitoring and reliability. The situation is different with red wood ants (RWA; Formica rufa-group (Hymenoptera: Formicidae)). They have stationary mounds on tectonically active, gas-bearing fault systems. These faults may be potential earthquake areas. For three years (2009–2012), two red wood ant mounds (Formica rufa-group), located at the seismically active Neuwied Basin (Eifel, Germany), have been monitored 24/7 by high-resolution cameras with both a color and an infrared sensor. Early results show that ants have a well-identifiable standard daily routine. Correlation with local seismic events suggests changes in the ants’ behavior hours before the earthquake: the nocturnal rest phase and daily activity are suppressed, and standard daily routine does not resume until the next day. At present, an automated image evaluation routine is being applied to the more than 45,000 hours of video streams. Based on this automated approach, a statistical analysis of the ants’ behavior will be carried out. In addition, other parameters (climate, geotectonic and biological), which may influence behavior, will be included in the analysis. PMID:26487310
Bischoff, Erik W M A; Akkermans, Reinier; Bourbeau, Jean; van Weel, Chris; Vercoulen, Jan H; Schermer, Tjard R J
2012-11-28
To assess the long term effects of two different modes of disease management (comprehensive self management and routine monitoring) on quality of life (primary objective), frequency and patients' management of exacerbations, and self efficacy (secondary objectives) in patients with chronic obstructive pulmonary disease (COPD) in general practice. 24 month, multicentre, investigator blinded, three arm, pragmatic, randomised controlled trial. 15 general practices in the eastern part of the Netherlands. Patients with COPD confirmed by spirometry and treated in general practice. Patients with very severe COPD or treated by a respiratory physician were excluded. A comprehensive self management programme as an adjunct to usual care, consisting of four tailored sessions with ongoing telephone support by a practice nurse; routine monitoring as an adjunct to usual care, consisting of 2-4 structured consultations a year with a practice nurse; or usual care alone (contacts with the general practitioner at the patients' own initiative). The primary outcome was the change in COPD specific quality of life at 24 months as measured with the chronic respiratory questionnaire total score. Secondary outcomes were chronic respiratory questionnaire domain scores, frequency and patients' management of exacerbations measured with the Nijmegen telephonic exacerbation assessment system, and self efficacy measured with the COPD self-efficacy scale. 165 patients were allocated to self management (n=55), routine monitoring (n=55), or usual care alone (n=55). At 24 months, adjusted treatment differences between the three groups in mean chronic respiratory questionnaire total score were not significant. Secondary outcomes did not differ, except for exacerbation management. Compared with usual care, more exacerbations in the self management group were managed with bronchodilators (odds ratio 2.81, 95% confidence interval 1.16 to 6.82) and with prednisolone, antibiotics, or both (3.98, 1.10 to 15.58). Comprehensive self management or routine monitoring did not show long term benefits in terms of quality of life or self efficacy over usual care alone in COPD patients in general practice. Patients in the self management group seemed to be more capable of appropriately managing exacerbations than did those in the usual care group. Clinical trials NCT00128765.
A novel process control method for a TT-300 E-Beam/X-Ray system
NASA Astrophysics Data System (ADS)
Mittendorfer, Josef; Gallnböck-Wagner, Bernhard
2018-02-01
This paper presents some aspects of the process control method for a TT-300 E-Beam/X-Ray system at Mediscan, Austria. The novelty of the approach is the seamless integration of routine monitoring dosimetry with process data. This allows to calculate a parametric dose for each production unit and consequently a fine grain and holistic process performance monitoring. Process performance is documented in process control charts for the analysis of individual runs as well as historic trending of runs of specific process categories over a specified time range.
Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F
2017-04-15
Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Mamo, Dereje; Hazel, Elizabeth; Lemma, Israel; Guenther, Tanya; Bekele, Abeba; Demeke, Berhanu
2014-10-01
Program managers require feasible, timely, reliable, and valid measures of iCCM implementation to identify problems and assess progress. The global iCCM Task Force developed benchmark indicators to guide implementers to develop or improve monitoring and evaluation (M&E) systems. To assesses Ethiopia's iCCM M&E system by determining the availability and feasibility of the iCCM benchmark indicators. We conducted a desk review of iCCM policy documents, monitoring tools, survey reports, and other rele- vant documents; and key informant interviews with government and implementing partners involved in iCCM scale-up and M&E. Currently, Ethiopia collects data to inform most (70% [33/47]) iCCM benchmark indicators, and modest extra effort could boost this to 83% (39/47). Eight (17%) are not available given the current system. Most benchmark indicators that track coordination and policy, human resources, service delivery and referral, supervision, and quality assurance are available through the routine monitoring systems or periodic surveys. Indicators for supply chain management are less available due to limited consumption data and a weak link with treatment data. Little information is available on iCCM costs. Benchmark indicators can detail the status of iCCM implementation; however, some indicators may not fit country priorities, and others may be difficult to collect. The government of Ethiopia and partners should review and prioritize the benchmark indicators to determine which should be included in the routine M&E system, especially since iCCMdata are being reviewed for addition to the HMIS. Moreover, the Health Extension Worker's reporting burden can be minimized by an integrated reporting approach.
40 CFR 141.621 - Routine monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 24 2012-07-01 2012-07-01 false Routine monitoring. 141.621 Section 141.621 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Stage 2 Disinfection Byproducts Requirements § 141...
40 CFR 141.621 - Routine monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Routine monitoring. 141.621 Section 141.621 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Stage 2 Disinfection Byproducts Requirements § 141...
40 CFR 141.621 - Routine monitoring.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 23 2011-07-01 2011-07-01 false Routine monitoring. 141.621 Section 141.621 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Stage 2 Disinfection Byproducts Requirements § 141...
40 CFR 141.621 - Routine monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Routine monitoring. 141.621 Section 141.621 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Stage 2 Disinfection Byproducts Requirements § 141...
DOE Program on Seismic Characterization for Regions of Interest to CTBT Monitoring,
1995-08-14
processing of the monitoring network data). While developing and testing the corrections and other parameters needed by the automated processing systems...the secondary network. Parameters tabulated in the knowledge base must be appropriate for routine automated processing of network data, and must also...operation of the PNDC, as well as to results of investigations of "special events" (i.e., those events that fail to locate or discriminate during automated
Automation of Physiologic Data Presentation and Alarms in the Post Anesthesia Care Unit
Aukburg, S.J.; Ketikidis, P.H.; Kitz, D.S.; Mavrides, T.G.; Matschinsky, B.B.
1989-01-01
The routine use of pulse oximeters, non-invasive blood pressure monitors and electrocardiogram monitors have considerably improved patient care in the post anesthesia period. Using an automated data collection system, we investigated the occurrence of several adverse events frequently revealed by these monitors. We found that the incidence of hypoxia was 35%, hypertension 12%, hypotension 8%, tachycardia 25% and bradycardia 1%. Discriminant analysis was able to correctly predict classification of about 90% of patients into normal vs. hypotensive or hypotensive groups. The system software minimizes artifact, validates data for epidemiologic studies, and is able to identify variables that predict adverse events through application of appropriate statistical and artificial intelligence techniques.
IDC Re-Engineering Phase 2 System Requirements Document Version 1.4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, James M.; Burns, John F.; Satpathi, Meara Allena
This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data,more » but includes requirements for the dissemination of radionuclide data and products.« less
IDC Re-Engineering Phase 2 System Requirements Document V1.3.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, James M.; Burns, John F.; Satpathi, Meara Allena
2015-12-01
This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide datamore » but includes requirements for the dissemination of radionuclide data and products.« less
Three years of operational experience from Schauinsland CTBT monitoring station.
Zähringer, M; Bieringer, J; Schlosser, C
2008-04-01
Data from three years of operation of a low-level aerosol sampler and analyzer (RASA) at Schauinsland monitoring station are reported. The system is part of the International Monitoring System (IMS) for verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The fully automatic system is capable to measure aerosol borne gamma emitters with high sensitivity and routinely quantifies 7Be and 212Pb. The system had a high level of data availability of 90% within the reporting period. A daily screening process rendered 66 tentative identifications of verification relevant radionuclides since the system entered IMS operation in February 2004. Two of these were real events and associated to a plausible source. The remaining 64 cases can consistently be explained by detector background and statistical phenomena. Inter-comparison with data from a weekly sampler operated at the same station shows instabilities of the calibration during the test phase and a good agreement since certification of the system.
Mounier-Jack, Sandra; Burchett, Helen Elizabeth Denise; Griffiths, Ulla Kou; Konate, Mamadou; Diarra, Kassibo Sira
2014-01-01
Objective: To evaluate the impact of the meningococcal A (MenA) vaccine introduction in Mali through mass campaigns on the routine immunization program and the wider health system. Methods: We used a mixed-methods case-study design, combining semi-structured interviews with 31 key informants, a survey among 18 health facilities, and analysis of routine health facility data on number of routine vaccinations and antenatal consultations before, during, and after the MenA vaccine campaign in December 2010. Survey and interview data were collected at the national level and in 2 regions in July and August 2011, with additional interviews in January 2012. Findings: Many health system functions were not affected—either positively or negatively—by the MenA vaccine introduction. The majority of effects were felt on the immunization program. Benefits included strengthened communication and social mobilization, surveillance, and provider skills. Drawbacks included the interruption of routine vaccination services in the majority of health facilities surveyed (67%). The average daily number of children receiving routine vaccinations was 79% to 87% lower during the 10-day campaign period than during other periods of the month. Antenatal care consultations were also reduced during the campaign period by 10% to 15%. Key informants argued that, with an average of 14 campaigns per year, mass campaigns would have a substantial cumulative negative effect on routine health services. Many also argued that the MenA campaign missed potential opportunities for health systems strengthening because integration with other health services was lacking. Conclusion: The MenA vaccine introduction interrupted routine vaccination and other health services. When introducing a new vaccine through a campaign, coverage of routine health services should be monitored alongside campaign vaccine coverage to highlight where and how long services are disrupted and to mitigate risks to routine services. PMID:25276567
Medina Lara, Antonieta; Kigozi, Jesse; Amurwon, Jovita; Muchabaiwa, Lazarus; Nyanzi Wakaholi, Barbara; Mujica Mota, Ruben E.; Walker, A. Sarah; Kasirye, Ronnie; Ssali, Francis; Reid, Andrew; Grosskurth, Heiner; Babiker, Abdel G.; Kityo, Cissy; Katabira, Elly; Munderi, Paula; Mugyenyi, Peter; Hakim, James; Darbyshire, Janet; Gibb, Diana M.; Gilks, Charles F.
2012-01-01
Background Despite funding constraints for treatment programmes in Africa, the costs and economic consequences of routine laboratory monitoring for efficacy and toxicity of antiretroviral therapy (ART) have rarely been evaluated. Methods Cost-effectiveness analysis was conducted in the DART trial (ISRCTN13968779). Adults in Uganda/Zimbabwe starting ART were randomised to clinically-driven monitoring (CDM) or laboratory and clinical monitoring (LCM); individual patient data on healthcare resource utilisation and outcomes were valued with primary economic costs and utilities. Total costs of first/second-line ART, routine 12-weekly CD4 and biochemistry/haematology tests, additional diagnostic investigations, clinic visits, concomitant medications and hospitalisations were considered from the public healthcare sector perspective. A Markov model was used to extrapolate costs and benefits 20 years beyond the trial. Results 3316 (1660LCM;1656CDM) symptomatic, immunosuppressed ART-naive adults (median (IQR) age 37 (32,42); CD4 86 (31,139) cells/mm3) were followed for median 4.9 years. LCM had a mean 0.112 year (41 days) survival benefit at an additional mean cost of $765 [95%CI:685,845], translating into an adjusted incremental cost of $7386 [3277,dominated] per life-year gained and $7793 [4442,39179] per quality-adjusted life year gained. Routine toxicity tests were prominent cost-drivers and had no benefit. With 12-weekly CD4 monitoring from year 2 on ART, low-cost second-line ART, but without toxicity monitoring, CD4 test costs need to fall below $3.78 to become cost-effective (<3xper-capita GDP, following WHO benchmarks). CD4 monitoring at current costs as undertaken in DART was not cost-effective in the long-term. Conclusions There is no rationale for routine toxicity monitoring, which did not affect outcomes and was costly. Even though beneficial, there is little justification for routine 12-weekly CD4 monitoring of ART at current test costs in low-income African countries. CD4 monitoring, restricted to the second year on ART onwards, could be cost-effective with lower cost second-line therapy and development of a cheaper, ideally point-of-care, CD4 test. PMID:22545079
Estill, Janne; Salazar-Vizcaya, Luisa; Blaser, Nello; Egger, Matthias; Keiser, Olivia
2015-01-01
The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs.
Estill, Janne; Salazar-Vizcaya, Luisa; Blaser, Nello; Egger, Matthias; Keiser, Olivia
2015-01-01
Background The cost-effectiveness of routine viral load (VL) monitoring of HIV-infected patients on antiretroviral therapy (ART) depends on various factors that differ between settings and across time. Low-cost point-of-care (POC) tests for VL are in development and may make routine VL monitoring affordable in resource-limited settings. We developed a software tool to study the cost-effectiveness of switching to second-line ART with different monitoring strategies, and focused on POC-VL monitoring. Methods We used a mathematical model to simulate cohorts of patients from start of ART until death. We modeled 13 strategies (no 2nd-line, clinical, CD4 (with or without targeted VL), POC-VL, and laboratory-based VL monitoring, with different frequencies). We included a scenario with identical failure rates across strategies, and one in which routine VL monitoring reduces the risk of failure. We compared lifetime costs and averted disability-adjusted life-years (DALYs). We calculated incremental cost-effectiveness ratios (ICER). We developed an Excel tool to update the results of the model for varying unit costs and cohort characteristics, and conducted several sensitivity analyses varying the input costs. Results Introducing 2nd-line ART had an ICER of US$1651-1766/DALY averted. Compared with clinical monitoring, the ICER of CD4 monitoring was US$1896-US$5488/DALY averted and VL monitoring US$951-US$5813/DALY averted. We found no difference between POC- and laboratory-based VL monitoring, except for the highest measurement frequency (every 6 months), where laboratory-based testing was more effective. Targeted VL monitoring was on the cost-effectiveness frontier only if the difference between 1st- and 2nd-line costs remained large, and if we assumed that routine VL monitoring does not prevent failure. Conclusion Compared with the less expensive strategies, the cost-effectiveness of routine VL monitoring essentially depends on the cost of 2nd-line ART. Our Excel tool is useful for determining optimal monitoring strategies for specific settings, with specific sex-and age-distributions and unit costs. PMID:25793531
Real-time seismic monitoring needs of a building owner - And the solution: A cooperative effort
Celebi, M.; Sanli, A.; Sinclair, M.; Gallant, S.; Radulescu, D.
2004-01-01
A recently implemented advanced seismic monitoring system for a 24-story building facilitates recording of accelerations and computing displacements and drift ratios in near-real time to measure the earthquake performance of the building. The drift ratio is related to the damage condition of the specific building. This system meets the owner's needs for rapid quantitative input to assessments and decisions on post-earthquake occupancy. The system is now successfully working and, in absence of strong shaking to date, is producing low-amplitude data in real time for routine analyses and assessment. Studies of such data to date indicate that the configured monitoring system with its building specific software can be a useful tool in rapid assessment of buildings and other structures following an earthquake. Such systems can be used for health monitoring of a building, for assessing performance-based design and analyses procedures, for long-term assessment of structural characteristics, and for long-term damage detection.
Metagenomic applications in environmental monitoring and bioremediation
Techtmann, Stephen M.; Hazen, Terry C.
2016-01-01
With the rapid advances in sequencing technology, the cost of sequencing has dramatically dropped and the scale of sequencing projects has increased accordingly. This has provided the opportunity for the routine use of sequencing techniques in the monitoring of environmental microbes. While metagenomic applications have been routinely applied to better understand the ecology and diversity of microbes, their use in environmental monitoring and bioremediation is increasingly common. In this review we seek to provide an overview of some of the metagenomic techniques used in environmental systems biology, addressing their application and limitation. We will also provide several recent examples ofmore » the application of metagenomics to bioremediation. We discuss examples where microbial communities have been used to predict the presence and extent of contamination, examples of how metagenomics can be used to characterize the process of natural attenuation by unculturable microbes, as well as examples detailing the use of metagenomics to understand the impact of biostimulation on microbial communities.« less
Developing Indicators for the Child and Youth Mental Health System in Ontario.
Yang, Julie; Kurdyak, Paul; Guttmann, Astrid
2016-01-01
When the Government of Ontario launched a comprehensive mental health and addictions strategy, the Institute for Clinical Evaluative Sciences (ICES) was tasked with developing a scorecard for ongoing monitoring of the child and youth mental health system. Using existing administrative and survey-based healthcare and education data, researchers at ICES developed a scorecard consisting of 25 indicators that described at-risk populations, child and youth mental healthcare and relevant outcomes. This scorecard is the first in Canada to report on performance indicators for the child and youth mental health system and provides a model for monitoring child and youth mental health using routinely collected administrative data.
Pillarisetti, Ajay; Allen, Tracy; Ruiz-Mercado, Ilse; Edwards, Rufus; Chowdhury, Zohir; Garland, Charity; Johnson, Michael; Litton, Charles D.; Lam, Nicholas L.; Pennise, David; Smith, Kirk R.
2017-01-01
Over the last 20 years, the Kirk R. Smith research group at the University of California Berkeley—in collaboration with Electronically Monitored Ecosystems, Berkeley Air Monitoring Group, and other academic institutions—has developed a suite of relatively inexpensive, rugged, battery-operated, microchip-based devices to quantify parameters related to household air pollution. These devices include two generations of particle monitors; data-logging temperature sensors to assess time of use of household energy devices; a time-activity monitoring system using ultrasound; and a CO2-based tracer-decay system to assess ventilation rates. Development of each system involved numerous iterations of custom hardware, software, and data processing and visualization routines along with both lab and field validation. The devices have been used in hundreds of studies globally and have greatly enhanced our understanding of heterogeneous household air pollution (HAP) concentrations and exposures and factors influencing them. PMID:28812989
Pillarisetti, Ajay; Allen, Tracy; Ruiz-Mercado, Ilse; Edwards, Rufus; Chowdhury, Zohir; Garland, Charity; Hill, L Drew; Johnson, Michael; Litton, Charles D; Lam, Nicholas L; Pennise, David; Smith, Kirk R
2017-08-16
Over the last 20 years, the Kirk R. Smith research group at the University of California Berkeley-in collaboration with Electronically Monitored Ecosystems, Berkeley Air Monitoring Group, and other academic institutions-has developed a suite of relatively inexpensive, rugged, battery-operated, microchip-based devices to quantify parameters related to household air pollution. These devices include two generations of particle monitors; data-logging temperature sensors to assess time of use of household energy devices; a time-activity monitoring system using ultrasound; and a CO₂-based tracer-decay system to assess ventilation rates. Development of each system involved numerous iterations of custom hardware, software, and data processing and visualization routines along with both lab and field validation. The devices have been used in hundreds of studies globally and have greatly enhanced our understanding of heterogeneous household air pollution (HAP) concentrations and exposures and factors influencing them.
Hien, Nguyen Tran; Tuan, Nguyen Anh; Ha, Hoang Thi Thanh; Thang, Pham Hong; Ha, Nguyen Thi Thanh; Tuan, Le Anh; Quang, Tran Dai; Tram, Tran Hong; Le Hai, Nguyen; Huong, Phan Thi Thu; Son, Vo Hai; Duc, Bui Hoang; Nga, Nguyen Thien; Jacka, David; Sabin, Keith
2015-01-01
In this report we describe a new approach in HIV sentinel surveillance that was piloted in Viet Nam in 2009 and is currently being rolled out in all provinces. It comprises a brief behavioural questionnaire added to the HIV sentinel surveillance surveys conducted routinely among people who inject drugs, female sex workers and men who have sex with men. Timely reporting of data from this system has resulted in improvements to HIV prevention efforts for most at-risk populations. PMID:25960922
Thanh, Duong Cong; Hien, Nguyen Tran; Tuan, Nguyen Anh; Ha, Hoang Thi Thanh; Thang, Pham Hong; Ha, Nguyen Thi Thanh; Tuan, Le Anh; Quang, Tran Dai; Tram, Tran Hong; Le Hai, Nguyen; Huong, Phan Thi Thu; Son, Vo Hai; Duc, Bui Hoang; Nga, Nguyen Thien; Jacka, David; Sabin, Keith
2015-01-01
In this report we describe a new approach in HIV sentinel surveillance that was piloted in Viet Nam in 2009 and is currently being rolled out in all provinces. It comprises a brief behavioural questionnaire added to the HIV sentinel surveillance surveys conducted routinely among people who inject drugs, female sex workers and men who have sex with men. Timely reporting of data from this system has resulted in improvements to HIV prevention efforts for most at-risk populations.
Monitoring temperatures in the vaccine cold chain in Bolivia.
Nelson, Carib; Froes, Paulo; Dyck, Anne Mie Van; Chavarría, Jeaneth; Boda, Enrique; Coca, Alberto; Crespo, Gladys; Lima, Heinz
2007-01-05
This study monitored vaccine cold chain temperatures during routine DTP-HB-Hib vaccine shipments from central stores to 11 communities in 3 provinces of Bolivia. In all 11 monitored shipments, vaccines were exposed to freezing temperatures at one or more points. In each of the shipments, temperatures below 0 degrees C were recorded for 2-50% of the monitoring period. Freezing occurred at almost every level of the cold chain distribution system, especially during district and health center storage and during transport to the province and district levels. Seven of the 11 shipments were exposed to temperatures above 8 degrees C, although none were exposed to excessive heat longer than 1.3% of the total monitoring period.
Improvement of burn pain management through routine pain monitoring and pain management protocol.
Yang, Hyeong Tae; Hur, Giyeun; Kwak, In-Suk; Yim, Haejun; Cho, Yong Suk; Kim, Dohern; Hur, Jun; Kim, Jong Hyun; Lee, Boung Chul; Seo, Cheong Hoon; Chun, Wook
2013-06-01
Pain management is an important aspect of burn management. We developed a routine pain monitoring system and pain management protocol for burn patients. The purpose of this study is to evaluate the effectiveness of our new pain management system. From May 2011 to November 2011, the prospective study was performed with 107 burn patients. We performed control group (n=58) data analysis and then developed the pain management protocol and monitoring system. Next, we applied our protocol to patients and performed protocol group (n=49) data analysis, and compared this to control group data. Data analysis was performed using the Numeric Rating Scale (NRS) of background pain and procedural pain, Clinician-Administered PTSD Scale (CAPS), Hamilton Depression Rating Scale (HDRS), State-Trait Anxiety Inventory Scale (STAIS), and Holmes and Rahe Stress Scale (HRSS). The NRS of background pain for the protocol group was significantly decreased compared to the control group (2.8±2.0 versus 3.9±1.9), and the NRS of procedural pain of the protocol group was significantly decreased compared to the control group (4.8±2.8 versus 3.7±2.5). CAPS and HDRS were decreased in the protocol group, but did not have statistical significance. STAIS and HRSS were decreased in the protocol group, but only the STAIS had statistical significance. Our new pain management system was effective in burn pain management. However, adequate pain management can only be accomplished by a continuous and thorough effort. Therefore, pain control protocol and pain monitoring systems need to be under constant revision and improvement using creative ideas and approaches. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Strain System for the Motion Base Shuttle Mission Simulator
NASA Technical Reports Server (NTRS)
Huber, David C.; Van Vossen, Karl G.; Kunkel, Glenn W.; Wells, Larry W.
2010-01-01
The Motion Base Shuttle Mission Simulator (MBSMS) Strain System is an innovative engineering tool used to monitor the stresses applied to the MBSMS motion platform tilt pivot frames during motion simulations in real time. The Strain System comprises hardware and software produced by several different companies. The system utilizes a series of strain gages, accelerometers, orientation sensor, rotational meter, scanners, computer, and software packages working in unison. By monitoring and recording the inputs applied to the simulator, data can be analyzed if weld cracks or other problems are found during routine simulator inspections. This will help engineers diagnose problems as well as aid in repair solutions for both current as well as potential problems.
Management Tools for Bus Maintenance: Current Practices and New Methods. Final Report.
ERIC Educational Resources Information Center
Foerster, James; And Others
Management of bus fleet maintenance requires systematic recordkeeping, management reporting, and work scheduling procedures. Tools for controlling and monitoring routine maintenance activities are in common use. These include defect and fluid consumption reports, work order systems, historical maintenance records, and performance and cost…
Nowik, Patrik; Bujila, Robert; Poludniowski, Gavin; Fransson, Annette
2015-07-08
The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two-year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service.
Satellite temperature monitoring and prediction system
NASA Technical Reports Server (NTRS)
Barnett, U. R.; Martsolf, J. D.; Crosby, F. L.
1980-01-01
The paper describes the Florida Satellite Freeze Forecast System (SFFS) in its current state. All data collection options have been demonstrated, and data collected over a three year period have been stored for future analysis. Presently, specific minimum temperature forecasts are issued routinely from November through March. The procedures for issuing these forecast are discussed. The automated data acquisition and processing system is described, and the physical and statistical models employed are examined.
Głowińska-Olszewska, Barbara; Urban, Mirosława; Peczyńska, Jadwiga; Florys, Bozena; Kowalewski, Marek
2005-01-01
Improved methods of diabetes therapy result in a near normoglycaemic state in many patients. This leads however unfortunately to more frequent hypoglycaemic incidents. Particularly small children, whose nervous system is not fully mature, are at high risk of central nervous system damage in case of hypoglycaemia. A new method of detail monitoring of glycaemia provides CGMS system. The aim of the study was to compare the glycaemic profile, with high attention to hypoglycaemia in groups of young and older children with diabetes type 1, using CGMS and routine glucose meter. We studied 32 children with diabetes type 1. Children were divided into groups: group I--small children, n=17 (<7 yrs of age), mean age 5,8 years, with disease duration--2,46 years, with mean HbA1c level--7,22%, and group II--older children, n=15 (>10 years of age), mean age--12 years, with disease duration--3 years, with HbA1c level--7,21%. Continuous glucose monitoring system (CGMS), by MiniMed, was applied in outpatient or hospital conditions, after short training of patient and parents; together with routine glucose meter measurements, 4-8 times/24 hours. In 9 patients from small children group CGMS was repeated after 2 months. Hypoglycaemic incidents detected with CGMS were similar in both groups: 4,6 in I group vs. 4,2 in II group (ns). Hypoglycaemic incidents found with meter were lower in I group--1,6 vs. 2,3 in II group (ns). Mean hypoglycaemic time/24 hour was longer in small children group: 101 min vs. 74 min in group II (p<00,05). In I group we found higher number of hypoglycaemic incidents during the night compared to group II--1,7 vs. 0,8 (p<00,05) and longer duration of night hypoglycaemia: in I group--56 min vs. 32 min in group II (p<00,05). Repeated CGMS study in 9 children from I group revealed decreased mean time of hypoglycaemia/24 hours from 134 min/24 h to 90 min/24 h (p<00,05) and decreased time of night hypoglycaemia from 65 min to 40 min (p<00,05), with a comparable number of hypoglycaemic incidents. Hypoglycaemic incidents found with routine meter measurements in small children were 1,6 vs. 4,6 hypoglycaemia found with CGMS (p<00,05), in the older children group routine measurement found 2,3 hypoglycaemia vs. 4,2 detected with CGMS (ns). 1. CGMS can be particularly usefull in monitoring glucose profile and detecting hypoglycaemia incidents, mainly nocturnal in small children. 2. CGMS allows to verify meal dose of insulin and to decrease postprandial hyperglycaemia. 3. Modification of insulin therapy on the base of CGMS helps to decrease the time of hypoglycaemia and hyperglycemia, particularly during the night.
Can Cities Sustain Life in the Greenhouse?
ERIC Educational Resources Information Center
Byrne, John; Hughes, Kristen; Toly, Noah; Wang, Young-Doo
2006-01-01
Data from the Global Environmental Monitoring System indicate that pollutants such as sulphur dioxide and total suspended particulate routinely appear in the lower atmosphere of major cities at concentrations well above health guidelines set by the World Health Organization. As well, cities are major contributors to the build-up of greenhouse…
INTEGRATED RESEARCH PLAN FOR LINKING BMPS AND WATERSHED WATER QUALITY IN SOUTHERN OHIO
Although it is routine for watershed management programs to coincide the monitoring of land use impacts and water quality at different spatial scales, rarely are the data collected or analyzed in such a strategic manner to be able to study the linkages among ecological systems ac...
DOT National Transportation Integrated Search
2017-07-01
Instances of fog or fog enhanced with smoke (non-photochemical smog) routinely reduce driver visibility on roadways throughout Georgia. Georgia has the fifth highest reduced-visibilityassociated crash frequency of any state. This report provides a...
Tuan, Nguyen Thanh; Alayon, Silvia; Do, Tran Thanh; Ngan, Tran Thi; Hajeebhoy, Nemat
2015-01-01
Little information is available about how to build a monitoring system to measure the output of preventive nutrition interventions, such as counselling on infant and young child feeding. This paper describes the Alive & Thrive Vietnam (A&T) project experience in nesting a large-scale project monitoring system into the existing public health information system (e.g. using the system and resources), and in using monitoring data to strengthen service delivery in 15 provinces with A&T franchises. From January 2012 to April 2014, the 780 A&T franchises provided 1,700,000 counselling contacts (~3/4 by commune franchises). In commune franchises in April 2014, 80% of mothers who were pregnant or with children under two years old had been to the counselling service at least one time, and 87% of clients had been to the service earlier. Monitoring data are used to track the progress of the project, make decisions, provide background for a costing study and advocate for the integration of nutrition counselling indicators into the health information system nationwide. With careful attention to the needs of stakeholders at multiple levels, clear data quality assurance measures and strategic feedback mechanisms, it is feasible to monitor the scale-up of nutrition programmes through the existing routine health information system.
Impact and Programmatic Implications of Routine Viral Load Monitoring in Swaziland
Parker, Lucy Anne; Azih, Charles; Okello, Velephi; Maphalala, Gugu; Jouquet, Guillaume; Kerschberger, Bernhard; Mekeidje, Calorine; Cyr, Joanne; Mafikudze, Arnold; Han, Win; Lujan, Johnny; Teck, Roger; Antierens, Annick; van Griensven, Johan; Reid, Tony
2014-01-01
Objective: To assess the programmatic quality (coverage of testing, counseling, and retesting), cost, and outcomes (viral suppression, treatment decisions) of routine viral load (VL) monitoring in Swaziland. Design: Retrospective cohort study of patients undergoing routine VL monitoring in Swaziland (October 1, 2012 to March 31, 2013). Results: Of 5563 patients eligible for routine VL testing monitoring in the period of study, an estimated 4767 patients (86%) underwent testing that year. Of 288 patients with detectable VL, 210 (73%) underwent enhanced adherence counseling and 202 (70%) had a follow-up VL within 6 months. Testing coverage was slightly lower in children, but coverage of retesting was similar between and age groups and sexes. Of those with a follow-up test, 126 (62%) showed viral suppression. The remaining 78 patients had World Health Organization–defined virologic failure; 41 (53%) were referred by the doctor for more adherence counseling, and 13 (15%) were changed to second-line therapy, equating to an estimated rate of 1.2 switches per 100 patient-years. Twenty-four patients (32%) were transferred out, lost to follow-up, or not reviewed by doctor. The “fully loaded” cost of VL monitoring was $35 per patient-year. Conclusions: Achieving good quality VL monitoring is feasible and affordable in resource-limited settings, although close supervision is needed to ensure good coverage of testing and counseling. The low rate of switch to second-line therapy in patients with World Health Organization–defined virologic failure seems to reflect clinician suspicion of ongoing adherence problems. In our study, the main impact of routine VL monitoring was reinforcing adherence rather than increasing use of second-line therapy. PMID:24872139
Turbulence Characterization and Control
1976-06-01
INSTRUMENTATION 2. 1 Real-Time Data Processing System 2. 2 Routine Meteorological Sensors 2. 3 Microthermal Sensors 2.4 Seeing Monitor 2. 5...Meteorological Tower l8 2-4 Fat Wire Microthermal Probe, Partially Disassembled to 19 Show Integral Electronics 2-5 ASP/SM Combination Shown Mounted...section. 1. 2 PROGRAM STATUS As of the date of this report, the status of the experimental systems are as follows: • Microthermal and
Evaluation of a hygiene monitor for detection of contamination in dental surgeries.
Douglas, C W; Rothwell, P S
1991-05-11
Routines for disinfecting working surfaces in dental surgeries are difficult to monitor without time-consuming and labour-intensive microbiological techniques, yet effective monitoring is a vital part of cross-infection control. Easy to use, on-site methods would be valuable in this context. This study evaluates a portable monitor, the Biotrace Hygiene Monitor, which uses bioluminescence to measure adenosine triphosphate (ATP) on surfaces. Under laboratory conditions, the ability of the monitor to detect whole saliva and Streptococcus sanguis was determined and, in the general practice environment, the level of ATP on surfaces in five dental surgeries was assessed. The minimum amount of saliva detectable was 0.5 microliters and in surgeries, the monitor readily identified numerous surfaces with fairly high levels of ATP. Routine cleaning methods sometimes left ATP on surfaces at levels which represented a cross-infection risk, if it is assumed that the ATP derived from patients' saliva. Modification of cleaning methods resulted in a reduction of ATP levels to within that which could be considered reasonably practicably safe. It is concluded that the Biotrace Hygiene Monitor offers a simple and valuable means of monitoring dental practice cleaning routines.
Energy monitoring system based on human activity in the workplace
NASA Astrophysics Data System (ADS)
Mustafa, Nur Hanim; Husain, Mohd Nor; Aziz, Mohamad Zoinol Abidin Abdul; Othman, Mohd Azlishah; Malek, Fareq
2015-05-01
Human behaviors always related to day routine activities in a smart house directly give the significant factor to manage energy usage in human life. An Addition that, the factor will contribute to the best efficiency of the system. This paper will focus on the monitoring efficiency based on duration time in office hours around 8am until 5pm which depend on human behavior at working place. Besides that, the correlation coefficient method is used to show the relation between energy consumption and energy saving based on the total hours of time energy spent. In future, the percentages of energy monitoring system usage will be increase to manage energy saving based on human behaviors. This scenario will help to see the human activity in the workplace in order to get the energy saving and support world green environment.
Poon, Art F. Y.; Gustafson, Réka; Daly, Patricia; Zerr, Laura; Demlow, S. Ellen; Wong, Jason; Woods, Conan K; Hogg, Robert S.; Krajden, Mel; Moore, David; Kendall, Perry; Montaner, Julio S. G.; Harrigan, P. Richard
2016-01-01
Background Due to the rapid evolution of HIV, infections with similar genetic sequences are likely to be related by recent transmission events. Clusters of related infections can represent subpopulations with high rates of HIV transmission. Here we describe the implementation of an automated “near real-time” system using clustering analysis of routinely collected HIV resistance genotypes to monitor and characterize HIV transmission hotspots in British Columbia (BC). Methods A monitoring system was implemented on the BC Drug Treatment Database, which currently holds over 32000 anonymized HIV genotypes for nearly 9000 residents of BC living with HIV. On average, five to six new HIV genotypes are deposited in the database every day, which triggers an automated re-analysis of the entire database. Clusters of five or more individuals were extracted on the basis of short phylogenetic distances between their respective HIV sequences. Monthly reports on the growth and characteristics of clusters were generated by the system and distributed to public health officers. Findings In June 2014, the monitoring system detected the expansion of a cluster by 11 new cases over three months, including eight cases with transmitted drug resistance. This cluster generally comprised young men who have sex with men. The subsequent report precipitated an enhanced public health follow-up to ensure linkage to care and treatment initiation in the affected subpopulation. Of the nine cases associated with this follow-up, all had already been linked to care and five cases had started treatment. Subsequent to the follow-up, three additional cases started treatment and the majority of cases achieved suppressed viral loads. Over the following 12 months, 12 new cases were detected in this cluster with a marked reduction in the onward transmission of drug resistance. Interpretation Our findings demonstrate the first application of an automated phylogenetic system monitoring a clinical database to detect a recent HIV outbreak and support the ensuing public health response. By making secondary use of routinely collected HIV genotypes, this approach is cost-effective, attains near realtime monitoring of new cases, and can be implemented in all settings where HIV genotyping is the standard of care. Funding This work was supported by the BC Centre for Excellence in HIV/AIDS and by grants from the Canadian Institutes for Health Research (CIHR HOP-111406, HOP-107544), the Genome BC, Genome Canada and CIHR Partnership in Genomics and Personalized Health (Large-Scale Applied Research Project HIV142 contract to PRH, JSGM, and AFYP), and by the US National Institute on Drug Abuse (1-R01-DA036307-01, 5-R01-031055-02, R01-DA021525-06, and R01-DA011591). PMID:27126490
Volcano monitoring using the Global Positioning System: Filtering strategies
Larson, K.M.; Cervelli, Peter; Lisowski, M.; Miklius, Asta; Segall, P.; Owen, S.
2001-01-01
Permanent Global Positioning System (GPS) networks are routinely used for producing improved orbits and monitoring secular tectonic deformation. For these applications, data are transferred to an analysis center each day and routinely processed in 24-hour segments. To use GPS for monitoring volcanic events, which may last only a few hours, real-time or near real-time data processing and subdaily position estimates are valuable. Strategies have been researched for obtaining station coordinates every 15 min using a Kalman filter; these strategies have been tested on data collected by a GPS network on Kilauea Volcano. Data from this network are tracked continuously, recorded every 30 s, and telemetered hourly to the Hawaiian Volcano Observatory. A white noise model is heavily impacted by data outages and poor satellite geometry, but a properly constrained random walk model fits the data well. Using a borehole tiltmeter at Kilauea's summit as ground-truth, solutions using different random walk constraints were compared. This study indicates that signals on the order of 5 mm/h are resolvable using a random walk standard deviation of 0.45 cm/???h. Values lower than this suppress small signals, and values greater than this have significantly higher noise at periods of 1-6 hours. Copyright 2001 by the American Geophysical Union.
Current Status of the Beam Position Monitoring System at TLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kuo, C. H.; Hu, K. H.; Chen, Jenny
2006-11-20
The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This reportmore » summarizes the system structure, the software environment and the preliminary beam test of the BPM system.« less
Current Status of the Beam Position Monitoring System at TLS
NASA Astrophysics Data System (ADS)
Kuo, C. H.; Hu, K. H.; Chen, Jenny; Lee, Demi; Wang, C. J.; Hsu, S. Y.; Hsu, K. T.
2006-11-01
The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This report summarizes the system structure, the software environment and the preliminary beam test of the BPM system.
A microcomputer-based whole-body counter for personnel routine monitoring.
Chou, H P; Tsai, T M; Lan, C Y
1993-05-01
The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.
Bidmanova, Sarka; Kotlanova, Marketa; Rataj, Tomas; Damborsky, Jiri; Trtilek, Martin; Prokop, Zbynek
2016-10-15
An advanced optical biosensor was developed based on the enzymatic reaction with halogenated aliphatic hydrocarbons that is accompanied by the fluorescence change of pH indicator. The device is applicable for the detection of halogenated contaminants in water samples with pH ranging from 4 to 10 and temperature ranging from 5 to 60°C. Main advantages of the developed biosensor are small size (60×30×190mm(3)) and portability, which together with short measurement time of 1min belong to crucial attributes of analytical technique useful for routine environmental monitoring. The biosensor was successfully applied for the detection of several important halogenated pollutants under laboratory conditions, e.g., 1,2-dichloroethane, 1,2,3-trichloropropane and γ-hexachlorocyclohexane, with the limits of detection of 2.7, 1.4 and 12.1mgL(-1), respectively. The continuous monitoring was demonstrated by repetitive injection of halogenated compound into measurement solution. Consequently, field trials under environmental settings were performed. The presence of 1,2-dichloroethane (10mgL(-1)) was proved unambiguously on one of three potentially contaminated sites in Czech Republic, and the same contaminant was monitored on contaminated locality in Serbia. Equipped by Global Positioning System, the biosensor was used for creation of a precise map of contamination. Concentrations determined by biosensor and by gas chromatograph coupled with mass spectrometer exhibited the correlation coefficient of 0.92, providing a good confidence for the routine use of the biosensor system in both field screening and monitoring. Copyright © 2015 Elsevier B.V. All rights reserved.
Vikingsson, Svante; Carlsson, Björn; Almer, Sven H C; Peterson, Curt
2009-06-01
Azathioprine and 6-mercaptopurine are often used in the treatment of patients with inflammatory bowel disease (IBD). They are prodrugs and undergo a complex metabolism to active and inactive metabolites. Thiopurine treatment is monitored in many laboratories by measuring metabolite concentrations in erythrocytes (red blood cells). The metabolites of interest are not measured directly but as hydrolysis products, which can be produced from several metabolites. The aim of this study was to examine which metabolites are actually measured during routine monitoring. Samples from 18 patients treated with a thiopurine were analyzed by a typical routine high-performance liquid chromatography method for therapeutic drug monitoring and by a newly developed specific method measuring thioguanosine monophosphate (TGMP), thioguanosine diphosphate (TGDP), and thioguanosine triphosphate (TGTP), as well as methylthioinosine monophosphate (meTIMP), and the results were compared. 6-Thioguanine nucleotide (TGN) values detected by the routine method were 69% (range 40%-90%) of the sum of TGMP, TGDP, and TGTP measured by the specific method. TGTP and TGDP contributed 85% (range 78%-90%) and 14% (range 10%-21%) of the TGN total, respectively. Thioguanosine was not found in any patient sample. The concentration of meTIMP obtained by the routine method was 548% of the value obtained by the specific method (range 340%-718%). The difference in TGN measurements between the routine and specific methods can be explained by low hydrolysis efficiency in the routine method, although the most likely explanation for the difference in meTIMP values is that not yet identified metabolites are codetermined in the routine high-performance liquid chromatography method. Concentrations reported as TGN during therapeutic drug monitoring of thiopurine metabolites consist of TGDP and TGTP with a minor contribution of the TGMP. Concentrations reported as meTIMP or methyl mercaptopurine consist in part of meTIMP, but other not yet identified metabolites are codetermined.
NASA Technical Reports Server (NTRS)
Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.
2015-01-01
Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.
First results with a lab-on-a-chip system for a fast Phytophthora diagnosis.
Sonja Horatzek; Stephan König; Stefan Wagner; Sabine Werres; Lydia Schwenkbier; Karina Weber; Jörg. Weber
2013-01-01
For Phytophthora spp. that are quarantine or regulated organisms, highly specific and sensitive diagnostic tools are recommended for surveys and monitoring. Furthermore, these diagnostic techniques should give results within a short time and should be not be too expensive. The techniques currently used for routine diagnosis of ...
40 CFR 63.11395 - What are the standards and compliance requirements for existing sources?
Code of Federal Regulations, 2013 CFR
2013-07-01
... routine and long-term maintenance) and continuous monitoring system. (4) A list of operating parameters... polymerization process equipment and monomer recovery process equipment and convey the collected gas stream.... (2) 0.05 lb/hr of AN from the control device for monomer recovery process equipment. (3) If you do...
40 CFR 63.11395 - What are the standards and compliance requirements for existing sources?
Code of Federal Regulations, 2012 CFR
2012-07-01
... routine and long-term maintenance) and continuous monitoring system. (4) A list of operating parameters... polymerization process equipment and monomer recovery process equipment and convey the collected gas stream.... (2) 0.05 lb/hr of AN from the control device for monomer recovery process equipment. (3) If you do...
40 CFR 63.11395 - What are the standards and compliance requirements for existing sources?
Code of Federal Regulations, 2014 CFR
2014-07-01
... routine and long-term maintenance) and continuous monitoring system. (4) A list of operating parameters... polymerization process equipment and monomer recovery process equipment and convey the collected gas stream.... (2) 0.05 lb/hr of AN from the control device for monomer recovery process equipment. (3) If you do...
Vaccine Safety Resources for Nurses
Shimabukuro, Tom T.; Hibbs, Beth F.; Moro, Pedro L.; Broder, Karen R.; Vellozzi, Claudia
2015-01-01
Overview Nurses are on the front lines of health care delivery, and many of them routinely administer immunizations. The authors describe the Centers for Disease Control and Prevention’s (CDC) vaccine safety monitoring systems, explaining how nurses can access inquiry channels and other immunization information resources. Examples of recent vaccine safety inquiries are also provided. PMID:26222474
NASA Technical Reports Server (NTRS)
1988-01-01
ARCO Solar manufactures PV Systems tailored to a broad variety of applications. PV arrays are routinely used at remote communications installations to operate large microwave repeaters, TV and radio repeaters rural telephone, and small telemetry systems that monitor environmental conditions. Also used to power agricultural water pumping systems, to provide electricity for isolated villages and medical clinics, for corrosion protection for pipelines and bridges, to power railroad signals, air/sea navigational aids, and for many types of military systems. ARCO is now moving into large scale generation for utilities.
Otten, Timothy G; Graham, Jennifer L; Harris, Theodore D; Dreher, Theo W
2016-09-01
While commonplace in clinical settings, DNA-based assays for identification or enumeration of drinking water pathogens and other biological contaminants remain widely unadopted by the monitoring community. In this study, shotgun metagenomics was used to identify taste-and-odor producers and toxin-producing cyanobacteria over a 2-year period in a drinking water reservoir. The sequencing data implicated several cyanobacteria, including Anabaena spp., Microcystis spp., and an unresolved member of the order Oscillatoriales as the likely principal producers of geosmin, microcystin, and 2-methylisoborneol (MIB), respectively. To further demonstrate this, quantitative PCR (qPCR) assays targeting geosmin-producing Anabaena and microcystin-producing Microcystis were utilized, and these data were fitted using generalized linear models and compared with routine monitoring data, including microscopic cell counts, sonde-based physicochemical analyses, and assays of all inorganic and organic nitrogen and phosphorus forms and fractions. The qPCR assays explained the greatest variation in observed geosmin (adjusted R(2) = 0.71) and microcystin (adjusted R(2) = 0.84) concentrations over the study period, highlighting their potential for routine monitoring applications. The origin of the monoterpene cyclase required for MIB biosynthesis was putatively linked to a periphytic cyanobacterial mat attached to the concrete drinking water inflow structure. We conclude that shotgun metagenomics can be used to identify microbial agents involved in water quality deterioration and to guide PCR assay selection or design for routine monitoring purposes. Finally, we offer estimates of microbial diversity and metagenomic coverage of our data sets for reference to others wishing to apply shotgun metagenomics to other lacustrine systems. Cyanobacterial toxins and microbial taste-and-odor compounds are a growing concern for drinking water utilities reliant upon surface water resources. Specific identification of the microorganism(s) responsible for water quality degradation is often complicated by the presence of co-occurring taxa capable of producing these undesirable metabolites. Here we present a framework for how shotgun metagenomics can be used to definitively identify problematic microorganisms and how these data can guide the development of rapid genetic assays for routine monitoring purposes. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Graham, Jennifer L.; Harris, Theodore D.
2016-01-01
ABSTRACT While commonplace in clinical settings, DNA-based assays for identification or enumeration of drinking water pathogens and other biological contaminants remain widely unadopted by the monitoring community. In this study, shotgun metagenomics was used to identify taste-and-odor producers and toxin-producing cyanobacteria over a 2-year period in a drinking water reservoir. The sequencing data implicated several cyanobacteria, including Anabaena spp., Microcystis spp., and an unresolved member of the order Oscillatoriales as the likely principal producers of geosmin, microcystin, and 2-methylisoborneol (MIB), respectively. To further demonstrate this, quantitative PCR (qPCR) assays targeting geosmin-producing Anabaena and microcystin-producing Microcystis were utilized, and these data were fitted using generalized linear models and compared with routine monitoring data, including microscopic cell counts, sonde-based physicochemical analyses, and assays of all inorganic and organic nitrogen and phosphorus forms and fractions. The qPCR assays explained the greatest variation in observed geosmin (adjusted R2 = 0.71) and microcystin (adjusted R2 = 0.84) concentrations over the study period, highlighting their potential for routine monitoring applications. The origin of the monoterpene cyclase required for MIB biosynthesis was putatively linked to a periphytic cyanobacterial mat attached to the concrete drinking water inflow structure. We conclude that shotgun metagenomics can be used to identify microbial agents involved in water quality deterioration and to guide PCR assay selection or design for routine monitoring purposes. Finally, we offer estimates of microbial diversity and metagenomic coverage of our data sets for reference to others wishing to apply shotgun metagenomics to other lacustrine systems. IMPORTANCE Cyanobacterial toxins and microbial taste-and-odor compounds are a growing concern for drinking water utilities reliant upon surface water resources. Specific identification of the microorganism(s) responsible for water quality degradation is often complicated by the presence of co-occurring taxa capable of producing these undesirable metabolites. Here we present a framework for how shotgun metagenomics can be used to definitively identify problematic microorganisms and how these data can guide the development of rapid genetic assays for routine monitoring purposes. PMID:27342564
Progress feedback and the OQ-system: The past and the future.
Lambert, Michael J
2015-12-01
A serious problem in routine clinical practice is clinician optimism about the benefit clients derive from the therapy that they offer compared to measured benefits. The consequence of seeing the silver lining is a failure to identify cases that, in the end, leave treatment worse-off than when they started or are simply unaffected. It has become clear that some methods of measuring, monitoring, and providing feedback to clinicians about client mental health status over the course of routine care improves treatment outcomes for clients at risk of treatment failure (Shimokawa, Lambert, & Smart, 2010) and thus is a remedy for therapist optimism by identifying cases at risk for poor outcomes. The current article presents research findings related to use of the Outcome Questionnaire-45 and Clinical Support Tools for this purpose. The necessary characteristics of feedback systems that work to benefit client's well-being are identified. In addition, suggestions for future research and use in routine care are presented. (c) 2015 APA, all rights reserved).
OpenROCS: a software tool to control robotic observatories
NASA Astrophysics Data System (ADS)
Colomé, Josep; Sanz, Josep; Vilardell, Francesc; Ribas, Ignasi; Gil, Pere
2012-09-01
We present the Open Robotic Observatory Control System (OpenROCS), an open source software platform developed for the robotic control of telescopes. It acts as a software infrastructure that executes all the necessary processes to implement responses to the system events that appear in the routine and non-routine operations associated to data-flow and housekeeping control. The OpenROCS software design and implementation provides a high flexibility to be adapted to different observatory configurations and event-action specifications. It is based on an abstract model that is independent of the specific hardware or software and is highly configurable. Interfaces to the system components are defined in a simple manner to achieve this goal. We give a detailed description of the version 2.0 of this software, based on a modular architecture developed in PHP and XML configuration files, and using standard communication protocols to interface with applications for hardware monitoring and control, environment monitoring, scheduling of tasks, image processing and data quality control. We provide two examples of how it is used as the core element of the control system in two robotic observatories: the Joan Oró Telescope at the Montsec Astronomical Observatory (Catalonia, Spain) and the SuperWASP Qatar Telescope at the Roque de los Muchachos Observatory (Canary Islands, Spain).
de Bruin, Jeroen S; Zeckl, Julia; Adlassnig, Katharina; Blacky, Alexander; Koller, Walter; Rappelsberger, Andrea; Adlassnig, Klaus-Peter
2017-01-01
The creation of clinical decision support systems has received a strong impulse over the last years, but their integration into a clinical routine has lagged behind, partly due to a lack of interoperability and trust by physicians. We report on the implementation of a clinical foundation framework in Arden Syntax, comprising knowledge units for (a) preprocessing raw clinical data, (b) the determination of single clinical concepts, and (c) more complex medical knowledge, which can be modeled through the composition and configuration of knowledge units in this framework. Thus, it can be tailored to clinical institutions or patients' caregivers. In the present version, we integrated knowledge units for several infection-related clinical concepts into the framework and developed a clinical event monitoring system over the framework that employs three different scenarios for monitoring clinical signs of bloodstream infection. The clinical event monitoring system was tested using data from intensive care units at Vienna General Hospital, Austria.
Technological advances in perioperative monitoring: Current concepts and clinical perspectives
Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar
2015-01-01
Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any. PMID:25788767
Technological advances in perioperative monitoring: Current concepts and clinical perspectives.
Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar
2015-01-01
Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any.
Piest, Benjamin A; Isberner, Maj-Britt; Richter, Tobias
2018-04-05
Previous research has shown that the validation of incoming information during language comprehension is a fast, efficient, and routine process (epistemic monitoring). Previous research on this topic has focused on epistemic monitoring during reading. The present study extended this research by investigating epistemic monitoring of audiovisual information. In a Stroop-like paradigm, participants (Experiment 1: adults; Experiment 2: 10-year-old children) responded to the probe words correct and false by keypress after the presentation of auditory assertions that could be either true or false with respect to concurrently presented pictures. Results provide evidence for routine validation of audiovisual information. Moreover, the results show a stronger and more stable interference effect for children compared with adults.
Bouvier-Colle, M-H; Mohangoo, A D; Gissler, M; Novak-Antolic, Z; Vutuc, C; Szamotulska, K; Zeitlin, J
2012-06-01
To assess capacity to develop routine monitoring of maternal health in the European Union using indicators of maternal mortality and severe morbidity. Analysis of aggregate data from routine statistical systems compiled by the EURO-PERISTAT project and comparison with data from national enquiries. Twenty-five countries in the European Union and Norway. Women giving birth in participating countries in 2003 and 2004. Application of a common collection of data by selecting specific International Classification of Disease codes from the 'Pregnancy, childbirth and the puerperium' chapter. External validity was assessed by reviewing the results of national confidential enquiries and linkage studies. Maternal mortality ratio, with distribution of specific obstetric causes, and severe acute maternal morbidity, which included: eclampsia, surgery and blood transfusion for obstetric haemorrhage, and intensive-care unit admission. In 22 countries that provided data, the maternal mortality ratio was 6.3 per 100,000 live births overall and ranged from 0 to 29.6. Under-ascertainment was evident from comparisons with studies that use enhanced identification of deaths. Furthermore, routine cause of death registration systems in countries with specific systems for audit reported higher maternal mortality ratio than those in countries without audits. For severe acute maternal morbidity, 16 countries provided data about at least one category of morbidity, and only three provided data for all categories. Reported values ranged widely (from 0.2 to 1.6 women with eclampsia per 1000 women giving birth and from 0.2 to 1.0 hysterectomies per 1000 women). Currently available data on maternal mortality and morbidity are insufficient for monitoring trends over time in Europe and for comparison between countries. Confidential enquiries into maternal deaths are recommended. © 2012 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2012 RCOG.
Bouvier-Colle, M-H; Mohangoo, AD; Gissler, M; Novak-Antolic, Z; Vutuc, C; Szamotulska, K; Zeitlin, J
2012-01-01
Objective To assess capacity to develop routine monitoring of maternal health in the European Union using indicators of maternal mortality and severe morbidity. Design Analysis of aggregate data from routine statistical systems compiled by the EURO-PERISTAT project and comparison with data from national enquiries. Setting Twenty-five countries in the European Union and Norway. Population Women giving birth in participating countries in 2003 and 2004. Methods Application of a common collection of data by selecting specific International Classification of Disease codes from the ‘Pregnancy, childbirth and the puerperium’ chapter. External validity was assessed by reviewing the results of national confidential enquiries and linkage studies. Main outcome measures Maternal mortality ratio, with distribution of specific obstetric causes, and severe acute maternal morbidity, which included: eclampsia, surgery and blood transfusion for obstetric haemorrhage, and intensive-care unit admission. Results In 22 countries that provided data, the maternal mortality ratio was 6.3 per 100 000 live births overall and ranged from 0 to 29.6. Under-ascertainment was evident from comparisons with studies that use enhanced identification of deaths. Furthermore, routine cause of death registration systems in countries with specific systems for audit reported higher maternal mortality ratio than those in countries without audits. For severe acute maternal morbidity, 16 countries provided data about at least one category of morbidity, and only three provided data for all categories. Reported values ranged widely (from 0.2 to 1.6 women with eclampsia per 1000 women giving birth and from 0.2 to 1.0 hysterectomies per 1000 women). Conclusions Currently available data on maternal mortality and morbidity are insufficient for monitoring trends over time in Europe and for comparison between countries. Confidential enquiries into maternal deaths are recommended. PMID:22571748
A Spike Cocktail Approach to Improve Microbial Performance Monitoring for Water Reuse.
Zimmerman, Brian D; Korajkic, Asja; Brinkman, Nichole E; Grimm, Ann C; Ashbolt, Nicholas J; Garland, Jay L
Water reuse, via either centralized treatment of traditional wastewater or decentralized treatment and on-site reuse, is becoming an increasingly important element of sustainable water management. Despite advances in waterborne pathogen detection methods, low and highly variable pathogen levels limit their utility for routine evaluation of health risks in water reuse systems. Therefore, there is a need to improve our understanding of the linkage between pathogens and more readily measured process indicators during treatment. This paper describes an approach for constructing spiking experiments to relate the behavior of viral, bacterial, and protozoan pathogens with relevant process indicators. General issues are reviewed, and the spiking protocol is applied as a case study example to improve microbial performance monitoring and health risk evaluation in a water reuse system. This approach provides a foundation for the development of novel approaches to improve real or near-real time performance monitoring of water recycling systems.
Natural Bridges National Monument photovoltaic power plant operations manual
NASA Astrophysics Data System (ADS)
Coleman, S. D.
1982-02-01
After a basic introduction and overview of the photovoltaic system at the Natural Bridges National Monument, a history of the project and a description of the installation, safety procedures essential for all operators and maintenance personnel are discussed. Locations and detailed descriptions of the equipment are provided to permit operators to identify the system controls and equipment. Step by step system operation procedures are described, including diesel generator start up and photovoltaic power system turn on. Information is provided about routine monitoring and maintenance of the system.
Bujila, Robert; Poludniowski, Gavin; Fransson, Annette
2015-01-01
The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two‐year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service PACS numbers: 87.57.C‐, 87.57.N‐, 87.57.Q‐ PMID:26219012
Detecting daily routines of older adults using sensor time series clustering.
Hajihashemi, Zahra; Yefimova, Maria; Popescu, Mihail
2014-01-01
The aim of this paper is to develop an algorithm to identify deviations in patterns of day-to-day activities of older adults to generate alerts to the healthcare providers for timely interventions. Daily routines, such as bathroom visits, can be monitored by automated in-home sensor systems. We present a novel approach that finds periodicity in sensor time series data using clustering approach. For this study, we used data set from TigerPlace, a retirement community in Columbia, MO, where apartments are equipped with a network of motion, pressure and depth sensors. A retrospective multiple case study (N=3) design was used to quantify bathroom visits as parts of the older adult's daily routine, over a 10-day period. The distribution of duration, number, and average time between sensor hits was used to define the confidence level for routine visit extraction. Then, a hierarchical clustering was applied to extract periodic patterns. The performance of the proposed method was evaluated through experimental results.
Although it is routine for watershed management programs to coincide the monitoring of land use impacts and water quality at different spatial scales, rarely are the data collected in a manner to elucidate the linkages among ecological systems across a drainage network. There rem...
Kongiganak Wind Turbine Replacement and System Upgrade Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boonstra, Patrick
2016-12-13
The Native Village of Kongiganak, Alaska was awarded a grant to upgrade the braking systems on five wind turbines and upgrade the monitoring and data collection unit to insure that enough energy is available to power the utility. The project manager for this award is Intelligent Energy Systems, LLC located in Anchorage, Alaska. In addition to accomplishing these upgrades, it was the intent for a local wind tech crew to be trained in Kongiganak so that routine maintenance and future repairs will be made by local workers.
Otten, Timothy; Graham, Jennifer L.; Harris, Theodore D.; Dreher, Theo
2016-01-01
While commonplace in clinical settings, DNA-based assays for identification or enumeration of drinking water pathogens and other biological contaminants remain widely unadopted by the monitoring community. In this study, shotgun metagenomics was used to identify taste-and-odor producers and toxin-producing cyanobacteria over a 2-year period in a drinking water reservoir. The sequencing data implicated several cyanobacteria, including Anabaena spp.,Microcystis spp., and an unresolved member of the order Oscillatoriales as the likely principal producers of geosmin, microcystin, and 2-methylisoborneol (MIB), respectively. To further demonstrate this, quantitative PCR (qPCR) assays targeting geosmin-producing Anabaena and microcystin-producing Microcystis were utilized, and these data were fitted using generalized linear models and compared with routine monitoring data, including microscopic cell counts, sonde-based physicochemical analyses, and assays of all inorganic and organic nitrogen and phosphorus forms and fractions. The qPCR assays explained the greatest variation in observed geosmin (adjusted R2 = 0.71) and microcystin (adjusted R2 = 0.84) concentrations over the study period, highlighting their potential for routine monitoring applications. The origin of the monoterpene cyclase required for MIB biosynthesis was putatively linked to a periphytic cyanobacterial mat attached to the concrete drinking water inflow structure. We conclude that shotgun metagenomics can be used to identify microbial agents involved in water quality deterioration and to guide PCR assay selection or design for routine monitoring purposes. Finally, we offer estimates of microbial diversity and metagenomic coverage of our data sets for reference to others wishing to apply shotgun metagenomics to other lacustrine systems.
Clark, J. Marshall
2009-01-01
Permethrin resistance has been reported worldwide and clinical failures to commercial pediculicides containing permethrin have likewise occurred. Permethrin resistance in head lice populations from the U.S. is widespread but is not yet uniform and the level of resistance is relatively low (~4–8 fold). Permethrin-resistant lice are cross-resistant to pyrethrins, PBO-synergized pyrethrins and to DDT. Nix®, when applied to human hair tufts following manufacture’s instructions, did not provide 100% control when assessed by the hair tuft bioassay in conjunction with the in vitro rearing system. Resistance to permethrin is due to knockdown resistance (kdr), which is the result of three point mutations within the α-subunit gene of the voltage-gated sodium channel that causes amino acid substitutions, leading to nerve insensitivity. A three-tiered resistance monitoring system has been established based on molecular resistance detection techniques. Quantitative sequencing (QS) has been developed to predict the kdr allele frequency in head lice at a population level. The speed, simplicity and accuracy of QS made it an ideal candidate for a routine primary resistance monitoring tool to screen a large number of louse populations as an alternative to conventional bioassay. As a secondary monitoring method, real-time PASA (rtPASA) has been devised for a more precise determination of low resistance allele frequencies. To obtain more detailed information on resistance allele zygosity, as well as allele frequency, serial invasive signal amplification reaction (SISAR) has been developed as an individual genotyping method. Our approach of using three tiers of molecular resistance detection should facilitate large-scale routine resistance monitoring of permethrin resistance in head lice using field-collected samples. PMID:20161186
[Computerized monitoring system in the operating center with UNIX and X-window].
Tanaka, Y; Hashimoto, S; Chihara, E; Kinoshita, T; Hirose, M; Nakagawa, M; Murakami, T
1992-01-01
We previously reported the fully automated data logging system in the operating center. Presently, we revised the system using a highly integrated operating system, UNIX instead of OS/9. With this multi-task and multi-window (X-window) system, we could monitor all 12 rooms in the operating center at a time. The system in the operating center consists of 2 computers, SONY NEWS1450 (UNIX workstation) and Sord M223 (CP/M, data logger). On the bitmapped display of the workstation, using X-window, the data of all the operating rooms can be visualized. Furthermore, 2 other minicomputers (Fujitsu A50 in the conference room, and A60 in the ICU) and a workstation (Sun3-80 in the ICU) were connected with ethernet. With the remote login function (NFS), we could easily obtain the data during the operation from outside the operating center. This system works automatically and needs no routine maintenance.
Ironmonger, Dean; Edeghere, Obaghe; Gossain, Savita; Bains, Amardeep; Hawkey, Peter M
2013-10-01
Antimicrobial resistance (AMR) is recognized as one of the most significant threats to human health. Local and regional AMR surveillance enables the monitoring of temporal changes in susceptibility to antibiotics and can provide prescribing guidance to healthcare providers to improve patient management and help slow the spread of antibiotic resistance in the community. There is currently a paucity of routine community-level AMR surveillance information. The HPA in England sponsored the development of an AMR surveillance system (AmSurv) to collate local laboratory reports. In the West Midlands region of England, routine reporting of AMR data has been established via the AmSurv system from all diagnostic microbiology laboratories. The HPA Regional Epidemiology Unit developed a web-enabled database application (AmWeb) to provide microbiologists, pharmacists and other stakeholders with timely access to AMR data using user-configurable reporting tools. AmWeb was launched in the West Midlands in January 2012 and is used by microbiologists and pharmacists to monitor resistance profiles, perform local benchmarking and compile data for infection control reports. AmWeb is now being rolled out to all English regions. It is expected that AmWeb will become a valuable tool for monitoring the threat from newly emerging or currently circulating resistant organisms and helping antibiotic prescribers to select the best treatment options for their patients.
Fault tolerant features and experiments of ANTS distributed real-time system
NASA Astrophysics Data System (ADS)
Dominic-Savio, Patrick; Lo, Jien-Chung; Tufts, Donald W.
1995-01-01
The ANTS project at the University of Rhode Island introduces the concept of Active Nodal Task Seeking (ANTS) as a way to efficiently design and implement dependable, high-performance, distributed computing. This paper presents the fault tolerant design features that have been incorporated in the ANTS experimental system implementation. The results of performance evaluations and fault injection experiments are reported. The fault-tolerant version of ANTS categorizes all computing nodes into three groups. They are: the up-and-running green group, the self-diagnosing yellow group and the failed red group. Each available computing node will be placed in the yellow group periodically for a routine diagnosis. In addition, for long-life missions, ANTS uses a monitoring scheme to identify faulty computing nodes. In this monitoring scheme, the communication pattern of each computing node is monitored by two other nodes.
Study of nuclear medicine practices in Portugal from an internal dosimetry perspective.
Bento, J; Teles, P; Neves, M; Santos, A I; Cardoso, G; Barreto, A; Alves, F; Guerreiro, C; Rodrigues, A; Santos, J A M; Capelo, C; Parafita, R; Martins, B
2012-05-01
Nuclear medicine practices involve the handling of a wide range of pharmaceuticals labelled with different radionuclides, for diagnostic and therapeutic purposes. This work intends to evaluate the potential risks of internal contamination of nuclear medicine staff in several Portuguese nuclear medicine services and to conclude about the requirement of a routine internal monitoring. A methodology proposed by the International Atomic Energy Agency (IAEA), providing a set of criteria to determine the need, or not, for an internal monitoring programme, was applied. The evaluation of the risk of internal contaminations in a given set of working conditions is based on the type and amount of radionuclides being handled, as well as the safety conditions with which they are manipulated. The application of the IAEA criteria showed that 73.1% of all the workers included in this study should be integrated in a routine monitoring programme for internal contaminations; more specifically, 100% of workers performing radioimmunoassay techniques should be monitored. This study suggests that a routine monitoring programme for internal exposures should be implemented in Portugal for most nuclear medicine workers.
Maintaining routine despite ongoing exposure to terrorism: a healthy strategy for adolescents?
Pat-Horenczyk, Ruth; Schiff, Miriam; Doppelt, Osnat
2006-08-01
To examine the association between ongoing terrorism and Israeli adolescents' routine activities. A total of 1336 junior high and high school students from Jerusalem (46.9% boys and 53.1% girls) self-reported on measures of maintaining or reducing their level of routine activities, perceived parental monitoring, posttraumatic symptoms (PTS) and functional impairment. We used linear regressions to explore possible associations between decreasing (or maintaining) level of routine activities, parental monitoring, and PTS and functional impairment. A majority of the adolescents reported that under the recurrent threat of terrorism they maintained their routine (i.e., 65.8% continued using public transportation). Similarly, more than half the students perceived their parents as encouraging them to maintain their routine activities. Furthermore, greater exposure to terrorism was associated with more PTS symptoms and functional impairment. Nonetheless, a reduced level of routine activities was a significant predictor for higher PTS and functional impairment, even after controlling for level of exposure to terrorism, gender and age. Similarly, perceived parental limiting of routine activities was a significant predictor for higher PTS and functional impairment, even after controlling for gender, age and the level of exposure to terrorism. Our results support practitioners' recommendations to encourage continuity in daily routine. Disruption of routine activities may result in the development of avoidance reactions that can lead to posttraumatic stress disorder.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Canfield, K.J.
1984-05-01
An EMCS (Energy Monitoring and Control System) can be described as a system that automatically takes care of routine operation of equipment and provides centralized reporting and override capabilities. Equipment controlled by an EMCS would be heating, ventilating, and air conditioning (HVAC) equipment, air compressors, and small package boiler units. The EMCS would obtain raw information (data) from sensors associated with the equipment and massage the data into useful information. The information obtained from the sensors plus additional information available to the EMCS would be used to control the equipment. The information would also be available to the operator inmore » the form of reports or in response to operator commands for specific information. EMCS are computerized systems that control and monitor energy consuming and producing equipment at Naval facilities. The larger systems have been installed with color-graphics cathode ray tube operator consoles to provide better information to the personnel operating these systems. This report summarizes the work done on defining an adequate operator console and recommends changes to the existing EMCS Guide Specifications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevins, N; Vanderhoek, M; Lang, S
2014-06-15
Purpose: Medical display monitor calibration and quality control present challenges to medical physicists. The purpose of this work is to demonstrate and share experiences with an open source package that allows for both initial monitor setup and routine performance evaluation. Methods: A software package, pacsDisplay, has been developed over the last decade to aid in the calibration of all monitors within the radiology group in our health system. The software is used to calibrate monitors to follow the DICOM Grayscale Standard Display Function (GSDF) via lookup tables installed on the workstation. Additional functionality facilitates periodic evaluations of both primary andmore » secondary medical monitors to ensure satisfactory performance. This software is installed on all radiology workstations, and can also be run as a stand-alone tool from a USB disk. Recently, a database has been developed to store and centralize the monitor performance data and to provide long-term trends for compliance with internal standards and various accrediting organizations. Results: Implementation and utilization of pacsDisplay has resulted in improved monitor performance across the health system. Monitor testing is now performed at regular intervals and the software is being used across multiple imaging modalities. Monitor performance characteristics such as maximum and minimum luminance, ambient luminance and illuminance, color tracking, and GSDF conformity are loaded into a centralized database for system performance comparisons. Compliance reports for organizations such as MQSA, ACR, and TJC are generated automatically and stored in the same database. Conclusion: An open source software solution has simplified and improved the standardization of displays within our health system. This work serves as an example method for calibrating and testing monitors within an enterprise health system.« less
1998 Technology Showcase. JOAP International Condition Monitoring Conference.
1998-04-01
Systems using Automated SEM/ EDX and New Diagnostic Routines 276 N. W Farrant & T. Luckhurst ADVANCED DIAGNOSTIC SYSTEMS Model-Based Diagnostics of Gas...Microscopy with Energy Dispersive X-Ray (SEM/ EDX ) micro analysis packages and Energy Dispersive X-Ray Fluorescence (EDXRF) analytical equipment. Therqfore...wear particles separated by ferrogram method. a- I WEAR PARTICLE A SLAS 97 (HOME PAGE) Fig I Home Page NONFE;RROUS MATERIAL A wW~ a48 -1, rV fr , ý b
Model-Based, Noninvasive Monitoring of Intracranial Pressure
2013-07-01
patients. A physiologically based model relates ICP to simultaneously measured waveforms of arterial blood pressure ( ABP ), obtained via radial... ABP and CBFV are currently measured as the clinical standard of care. The project’s major accomplishments include: assembling a suitable system for...synchronized arterial blood pressure ( ABP ) and cerebral blood flow velocity (CBFV) waveform measurements that can be obtained quite routinely. Our processing
Poon, Art F Y; Gustafson, Réka; Daly, Patricia; Zerr, Laura; Demlow, S Ellen; Wong, Jason; Woods, Conan K; Hogg, Robert S; Krajden, Mel; Moore, David; Kendall, Perry; Montaner, Julio S G; Harrigan, P Richard
2016-05-01
HIV evolves rapidly and therefore infections with similar genetic sequences are likely linked by recent transmission events. Clusters of related infections can represent subpopulations with high rates of transmission. We describe the implementation of an automated near real-time system to monitor and characterise HIV transmission hotspots in British Columbia, Canada. In this implementation case study, we applied a monitoring system to the British Columbia drug treatment database, which holds more than 32 000 anonymised HIV genotypes for nearly 9000 residents of British Columbia living with HIV. On average, five to six new HIV genotypes are deposited in the database every day, which triggers an automated reanalysis of the entire database. We extracted clusters of five or more individuals with short phylogenetic distances between their respective HIV sequences. The system generated monthly reports of the growth and characteristics of clusters that were distributed to public health officers. In June, 2014, the monitoring system detected the expansion of a cluster by 11 new cases during 3 months, including eight cases with transmitted drug resistance. This cluster generally comprised young men who have sex with men. The subsequent report precipitated an enhanced public health follow-up to ensure linkage to care and treatment initiation in the affected subpopulation. Of the nine cases associated with this follow-up, all had already been linked to care and five cases had started treatment. Subsequent to the follow-up, three additional cases started treatment and most cases achieved suppressed viral loads. During the next 12 months, we detected 12 new cases in this cluster with reduction in the onward transmission of drug resistance. Our findings show the first application of an automated phylogenetic system monitoring a clinical database to detect a recent HIV outbreak and support the ensuing public health response. By making secondary use of routinely collected HIV genotypes, this approach is cost-effective, attains near real-time monitoring of new cases, and can be implemented in all settings in which HIV genotyping is the standard of care. BC Centre for Excellence in HIV/AIDS, the Canadian Institutes for Health Research, the Genome Canada-CIHR Partnership in Genomics and Personalized Health, and the US National Institute on Drug Abuse. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Orekhova, N.; Perkov, A.; Sasyuk, V.
2017-07-01
Here we present the summary of first years of operation and the first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-MegaTORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (900 square degrees) or narrow (100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds.The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT also include faint meteors and artificial satellites.
NASA Astrophysics Data System (ADS)
Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Orekhova, N.; Perkov, A.; Sasyuk, V.
2017-06-01
Here we present the summary of first years of operation and the first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-MegaTORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (˜900 square degrees) or narrow (˜100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds.The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT include faint meteors and artificial satellites.
Menychtas, Andreas; Tsanakas, Panayiotis
2016-01-01
The proper acquisition of biosignals data from various biosensor devices and their remote accessibility are still issues that prevent the wide adoption of point-of-care systems in the routine of monitoring chronic patients. This Letter presents an advanced framework for enabling patient monitoring that utilises a cloud computing infrastructure for data management and analysis. The framework introduces also a local mechanism for uniform biosignals collection from wearables and biosignal sensors, and decision support modules, in order to enable prompt and essential decisions. A prototype smartphone application and the related cloud modules have been implemented for demonstrating the value of the proposed framework. Initial results regarding the performance of the system and the effectiveness in data management and decision-making have been quite encouraging. PMID:27222731
Menychtas, Andreas; Tsanakas, Panayiotis; Maglogiannis, Ilias
2016-03-01
The proper acquisition of biosignals data from various biosensor devices and their remote accessibility are still issues that prevent the wide adoption of point-of-care systems in the routine of monitoring chronic patients. This Letter presents an advanced framework for enabling patient monitoring that utilises a cloud computing infrastructure for data management and analysis. The framework introduces also a local mechanism for uniform biosignals collection from wearables and biosignal sensors, and decision support modules, in order to enable prompt and essential decisions. A prototype smartphone application and the related cloud modules have been implemented for demonstrating the value of the proposed framework. Initial results regarding the performance of the system and the effectiveness in data management and decision-making have been quite encouraging.
Tse, Tamara; Carey, Leeanne; Cadilhac, Dominique; Koh, Gerald Choon-Huat; Baum, Carolyn
2016-10-01
Aim To examine how Australia, Singapore and the United States of America (USA) match to the World Stroke Organization Global Stroke Services health system monitoring indicators (HSI). Design Descriptive comparative study Participants The health systems of Australia, Singapore, the USA. Outcome measures Published data available from each country were mapped to the 10 health system monitoring indicators proposed by the World Stroke Organization. Results Most health system monitoring indicators were at least partially met in each country. Thrombolytic agents were available for use in acute stroke. Stroke guidelines and stroke registry data were available in all three countries. Stroke incidence, prevalence, and mortality rates were available but at non-uniform times post-stroke. The International Classification of Disease 9 or 10 coding systems are used in all three countries. Standardized clinical audits are routine in Australia and the USA, but not in Singapore. The use of the modified Rankin Scale is collected sub-acutely but not at one year post-stroke in all three countries. Conclusions The three developed countries are performing well against the World Stroke Organization health system monitoring indicators for acute and sub-acute stroke care. However, improvements in stroke risk assessment and at one-year post-stroke outcome measurement are needed.
The Savannah River Site's Groundwater Monitoring Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-01-01
The Environmental Monitoring Section of the Environmental and Health Protection (EHP) Department administers the Savannah River Site's Groundwater Monitoring Program. During fourth quarter 1989 (October--December), EHP conducted routine sampling of monitoring wells and drinking water locations. EHP collected the drinking water samples from Savannah River Site (SRS) drinking water systems supplied by wells. EHP established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria aid personnel in sample scheduling, interpretation of data, and trend identification. An explanation of flagging criteria for the fourth quarter is presented in the Flagging Criteria sectionmore » of this document. All analytical results from fourth quarter 1989 are listed in this report, which is distributed to all waste-site custodians.« less
The Savannah River Site`s Groundwater Monitoring Program. Fourth quarter, 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-12-31
The Environmental Monitoring Section of the Environmental and Health Protection (EHP) Department administers the Savannah River Site`s Groundwater Monitoring Program. During fourth quarter 1989 (October--December), EHP conducted routine sampling of monitoring wells and drinking water locations. EHP collected the drinking water samples from Savannah River Site (SRS) drinking water systems supplied by wells. EHP established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria aid personnel in sample scheduling, interpretation of data, and trend identification. An explanation of flagging criteria for the fourth quarter is presented in the Flagging Criteria sectionmore » of this document. All analytical results from fourth quarter 1989 are listed in this report, which is distributed to all waste-site custodians.« less
Rice, Brian; Boulle, Andrew; Baral, Stefan; Egger, Matthias; Mee, Paul; Fearon, Elizabeth; Reniers, Georges; Todd, Jim; Schwarcz, Sandra; Weir, Sharon; Rutherford, George; Hargreaves, James
2018-04-03
The global HIV response has entered a new phase with the recommendation of treating all persons living with HIV with antiretroviral therapy, and with the goals of reducing new infections and AIDS-related deaths to fewer than 500,000 by 2020. This new phase has intensive data requirements that will need to utilize routine data collected through service delivery platforms to monitor progress toward these goals. With a focus on sub-Saharan African, we present the following priorities to improve the demand, supply, and use of routine HIV data: (1) strengthening patient-level HIV data systems that support continuity of clinical care and document sentinel events; (2) leveraging data from HIV testing programs; (3) using targeting data collection in communities and among clients; and (4) building capacity and promoting a culture of HIV data quality assessment and use. When fully leveraged, routine data can efficiently provide timely information at a local level to inform action, as well as provide information at scale with wide geographic coverage to strengthen estimation efforts. ©Brian Rice, Andrew Boulle, Stefan Baral, Matthias Egger, Paul Mee, Elizabeth Fearon, Georges Reniers, Jim Todd, Sandra Schwarcz, Sharon Weir, George Rutherford, James Hargreaves. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 03.04.2018.
Performance Evaluation of Three Blood Glucose Monitoring Systems Using ISO 15197
Bedini, José Luis; Wallace, Jane F.; Pardo, Scott; Petruschke, Thorsten
2015-01-01
Background: Blood glucose monitoring is an essential component of diabetes management. Inaccurate blood glucose measurements can severely impact patients’ health. This study evaluated the performance of 3 blood glucose monitoring systems (BGMS), Contour® Next USB, FreeStyle InsuLinx®, and OneTouch® Verio™ IQ, under routine hospital conditions. Methods: Venous blood samples (N = 236) obtained for routine laboratory procedures were collected at a Spanish hospital, and blood glucose (BG) concentrations were measured with each BGMS and with the available reference (hexokinase) method. Accuracy of the 3 BGMS was compared according to ISO 15197:2013 accuracy limit criteria, by mean absolute relative difference (MARD), consensus error grid (CEG) and surveillance error grid (SEG) analyses, and an insulin dosing error model. Results: All BGMS met the accuracy limit criteria defined by ISO 15197:2013. While all measurements of the 3 BGMS were within low-risk zones in both error grid analyses, the Contour Next USB showed significantly smaller MARDs between reference values compared to the other 2 BGMS. Insulin dosing errors were lowest for the Contour Next USB than compared to the other systems. Conclusions: All BGMS fulfilled ISO 15197:2013 accuracy limit criteria and CEG criterion. However, taking together all analyses, differences in performance of potential clinical relevance may be observed. Results showed that Contour Next USB had lowest MARD values across the tested glucose range, as compared with the 2 other BGMS. CEG and SEG analyses as well as calculation of the hypothetical bolus insulin dosing error suggest a high accuracy of the Contour Next USB. PMID:26445813
Lin, Chin-Teng; Ko, Li-Wei; Chang, Meng-Hsiu; Duann, Jeng-Ren; Chen, Jing-Ying; Su, Tung-Ping; Jung, Tzyy-Ping
2010-01-01
Biomedical signal monitoring systems have rapidly advanced in recent years, propelled by significant advances in electronic and information technologies. Brain-computer interface (BCI) is one of the important research branches and has become a hot topic in the study of neural engineering, rehabilitation, and brain science. Traditionally, most BCI systems use bulky, wired laboratory-oriented sensing equipments to measure brain activity under well-controlled conditions within a confined space. Using bulky sensing equipments not only is uncomfortable and inconvenient for users, but also impedes their ability to perform routine tasks in daily operational environments. Furthermore, owing to large data volumes, signal processing of BCI systems is often performed off-line using high-end personal computers, hindering the applications of BCI in real-world environments. To be practical for routine use by unconstrained, freely-moving users, BCI systems must be noninvasive, nonintrusive, lightweight and capable of online signal processing. This work reviews recent online BCI systems, focusing especially on wearable, wireless and real-time systems. Copyright 2009 S. Karger AG, Basel.
Methods to improve routine bioassay monitoring for freshly separated, poorly transported plutonium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bihl, D.E.; Lynch, T.P.; Carbaugh, E.H.
1988-09-01
Several human cases involving inhalation of plutonium oxide at Hanford have shown clearance half-times from the lung that are much longer than the 500-day half-time recommended for class Y plutonium in Publication 30 of the International Commission on Radiological Protection(ICRP). The more tenaciously retained material is referred to as super class Y plutonium. The ability to detect super class Y plutonium by current routine bioassay measurements is shown to be poor. Pacific Northwest Laboratory staff involved in the Hanford Internal Dosimetry Program investigated four methods to se if improvements in routine monitoring of workers for fresh super class Y plutoniummore » are feasible. The methods were lung counting, urine sampling, fecal sampling, and use of diethylenetriaminepentaacetate (DTPA) to enhance urinary excretion. Use of DTPA was determined to be not feasible. Routine fecal sampling was found to be feasible but not recommended. Recommendations were made to improve the detection level for routine annual urinalysis and routine annual lung counting. 12 refs., 9 figs., 7 tabs.« less
Extra-Articular Retained Missiles; Is Surveillance of Lead Levels Needed?
Nickel, Walter N; Steelman, Theodore J; Sabath, Zena R; Potter, Benjamin K
2018-03-01
Although gunshot wounds are relatively common, lead toxicity associated with extra-articular retained missiles (EARMs) is an uncommon, yet potentially devastating, complication. Although the risk of lead toxicity with intra-articular retained missiles is well known, EARMs are routinely left in situ or only removed in selected circumstances secondary to the relatively rare occurrence of complications. We first describe a patient with systemic lead poisoning associated with retained lead fragments after a gunshot-induced left femoral shaft fracture. We then performed a systematic review of the literature to answer the following questions: (1) In the setting of retained extra-articular bullets and/or bullet fragments, is regular monitoring and/or surveillance of lead levels in the blood routinely indicated? and, if so, (2) what are the selected factors that portend an increased risk for elevations in blood lead levels in the setting of retained extra-articular bullets and/or bullet fragments? The systematic review was conducted according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) reporting guidelines, of the English language literature utilizing Medline (PubMed), EMBASE, Cochrane, and CINAHL on the topic of lead poisoning, retained bullet, and gunshot wound, and then searched for additional references by manually searching of bibliographies of the included references. Studies were included if they provided clinical data on one or both of our study questions; included studies were evaluated using the accepted levels of evidence. Routine monitoring or surveillance of lead levels in blood is recommended in all cases of EARM at the time of hospital admission and again at discharge, followed by monthly intervals until 3 mo post-injury and then again at 1 yr post-injury. The studies identified demonstrated significant risk factors for elevated blood lead levels in the setting of EARM, which included the number of retained missiles and concomitant fracture. Recommendations for routine monitoring and surveillance of blood lead levels in all cases of EARM are conflicting, but such monitoring appears to be warranted given that the potential risks and morbidity associated with systemic lead poisoning are outweighed by any potential harm of short-term, blood lead level monitoring. Outside of concomitant fracture, the evidence for making further clinical recommendations regarding selected risk factors that portend an increased risk for elevated blood lead levels after gunshot injury is weak. Larger level II and III studies are needed to determine the indications for and frequency of lead toxicity screening after retained EARM. Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2018. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Zhao, H; Green, H; Lackenby, A; Donati, M; Ellis, J; Thompson, C; Bermingham, A; Field, J; Sebastianpillai, P; Zambon, M; Watson, Jm; Pebody, R
2014-01-23
During the 2009 influenza A(H1N1) pandemic, a new laboratory-based virological sentinel surveillance system, the Respiratory DataMart System (RDMS), was established in a network of 14 Health Protection Agency (now Public Health England (PHE)) and National Health Service (NHS) laboratories in England. Laboratory results (both positive and negative) were systematically collected from all routinely tested clinical respiratory samples for a range of respiratory viruses including influenza, respiratory syncytial virus (RSV), rhinovirus, parainfluenza virus, adenovirus and human metapneumovirus (hMPV). The RDMS also monitored the occurrence of antiviral resistance of influenza viruses. Data from the RDMS for the 2009–2012 period showed that the 2009 pandemic influenza virus caused three waves of activity with different intensities during the pandemic and post pandemic periods. Peaks in influenza A(H1N1)pdm09 positivity (defined as number of positive samples per total number of samples tested) were seen in summer and autumn in 2009, with slightly higher peak positivity observed in the first post-pandemic season in 2010/2011. The influenza A(H1N1)pdm09 virus strain almost completely disappeared in the second postpandemic season in 2011/2012. The RDMS findings are consistent with other existing community-based virological and clinical surveillance systems. With a large sample size, this new system provides a robust supplementary mechanism, through the collection of routinely available laboratory data at minimum extra cost, to monitor influenza as well as other respiratory virus activity. A near real-time, daily reporting mechanism in the RDMS was established during the London 2012 Olympic and Paralympic Games. Furthermore, this system can be quickly adapted and used to monitor future influenza pandemics and other major outbreaks of respiratory infectious disease, including novel pathogens.
Achieving glycemic control in special populations in hospital: perspectives in practice.
Cheng, Alice Y Y
2014-04-01
Achieving and maintaining glycemic control in patients with diabetes admitted to hospital is challenging because of the many competing factors of nutrition, pharmacotherapy and other patient-related and systemic factors. For patients receiving enteral or parenteral feeding, eating irregularly or receiving glucocorticoid therapy, the challenges are even greater. The basic principles to follow when managing glycemia in these populations are as follows: 1) Recognition of those at risk for hyperglycemia; 2) frequent bedside glucose monitoring; 3) a proactive approach with routine insulin administration based on the predicted glucose patterns; 4) constant reassessment of the glycemic status and titration of the routine insulin accordingly. Copyright © 2014 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
Establishing treatment protocols for clinical mastitis.
Roberson, Jerry R
2003-03-01
Each farm has a unique mix of mastitis pathogens and management procedures that have evolved over time. The herd veterinarian should work with the manager/owner to systematically develop treatment protocols that meet the needs and management of the farm. To establish a mastitis treatment protocol, it is necessary to develop a system to routinely identify clinical mastitis cases, develop a herd-specific severity level assessment system, manage the clinical mastitis cases based on severity level and culture result (when available), avoid antibiotic residues, and monitor the success of the system and alter the protocol as necessary.
NASA Technical Reports Server (NTRS)
Lekki, John; Tokars, Roger; Jaros, Dave; Riggs, M. Terrence; Evans, Kenneth P.; Gyekenyesi, Andrew
2009-01-01
A self diagnostic accelerometer system has been shown to be sensitive to multiple failure modes of charge mode accelerometers. These failures include sensor structural damage, an electrical open circuit and most importantly sensor detachment. In this paper, experimental work that was performed to determine the capabilities of a self diagnostic accelerometer system while operating in the presence of various levels of mechanical noise, emulating real world conditions, is presented. The results show that the system can successfully conduct a self diagnostic routine under these conditions.
Real-time capability of GEONET system and its application to crust monitoring
NASA Astrophysics Data System (ADS)
Yamagiwa, Atsushi; Hatanaka, Yuki; Yutsudo, Toru; Miyahara, Basara
2006-03-01
The GPS Earth Observation Network system (GEONET) has been playing an important role in monitoring the crustal deformation of Japan. Since its start of operation, the requirements for accuracy and timeliness have become higher and higher. On the other hand, recent broadband communication infrastructure has had capability to realize real-time crust monitoring and to aid the development of a location-based service. In early 2003, the Geographical Survey Institute (GSI) upgraded the GEONET system to meet new requirements. The number of stations became 1200 in total by March, 2003. The antennas were unified to the choke ring antennas of Dorne Margolin T-type and the receivers were replaced with new ones that are capable of real-time observation and data transfer. The new system uses IP-connection through IP-VPN (Internet Protocol Virtual Private Network) for data transfer, which is provided by communication companies. The Data Processing System, which manages the observation data and analyses in GEONET, has 7 units. GEONET carries out three kinds of routine analyses and an analysis of RTK-type for emergencies. The new system has shown its capability for real-time crust monitoring, for example, the precise and rapid detection of coseismic (and post-seismic) motion caused by 2003 Tokachi-Oki earthquake.
SU-E-T-354: Efficient and Enhanced QA Testing of Linear Accelerators Using a Real-Time Beam Monitor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jung, J; Farrokhkish, M; Norrlinger, B
2015-06-15
Purpose: To investigate the feasibility of performing routine QA tests of linear accelerators (Linac) using the Integral Quality Monitoring (IQM) system. The system, consisting of a 1-D sensitivity gradient large area ion-chamber mounted at the collimator, allows automatic collection and analysis of beam data. Methods: The IQM was investigated to perform several QA constancy tests, similar to those recommended by AAPM TG142, of a Linac including: beam output, MLC calibration, beam symmetry, relative dose factor (RDF), dose linearity, output as a function of gantry angle and dose rate. All measurements by the IQM system accompanied a reference measurement using amore » conventional dosimetry system and were performed on an Elekta Infinity Linac with Agility MLC. The MLC calibration check is done using a Picket-Fence type 2×10cm{sup 2} field positioned at different off-axis locations along the chamber gradient. Beam symmetry constancy values are established by signals from an 4×4cm{sup 2} aperture located at various off-axis positions; the sensitivity of the test was determined by the changes in the signals in response to a tilt in the beam. The data for various square field sizes were used to develop a functional relationship with RDF. Results: The IQM tracked the beam output well within 1% of the reference ion-chamber readings. The Picket-Fence type field test detected a 1mm shift error of one MLC bank. The system was able to detect 2.5% or greater beam asymmetry. The IQM results for all other QA tests were found to agree with the reference values to within 0.5%. Conclusion: It was demonstrated that the IQM system can effectively monitor the Linac performance parameters for the purpose of routine QA constancy tests. With minimum user interactions a comprehensive set of tests can be performed efficiently, allowing frequent monitoring of the Linac. The presenting author’s salary is funded by the manufacturer of the QA device. All the other authors have financial interests with the commercialization of this QA device.« less
Dugas, Martin; Eckholt, Markus; Bunzemeier, Holger
2008-01-01
Background Monitoring of hospital information system (HIS) usage can provide insights into best practices within a hospital and help to assess time trends. In terms of effort and cost of benchmarking, figures derived automatically from the routine HIS system are preferable to manual methods like surveys, in particular for repeated analysis. Methods Due to relevance for quality management and efficient resource utilization we focused on time-to-completion of discharge letters (assessed by CT-plots) and usage of patient scheduling. We analyzed these parameters monthly during one year at a major university hospital in Germany. Results We found several distinct patterns of discharge letter documentation indicating a large heterogeneity of HIS usage between different specialties (completeness 51 – 99%, delays 0 – 90 days). Overall usage of scheduling increased during the observation period by 62%, but again showed a considerable variation between departments. Conclusion Regular monitoring of HIS key figures can contribute to a continuous HIS improvement process. PMID:18423046
Clinical application of a light-pen computer system for quantitative angiography
NASA Technical Reports Server (NTRS)
Alderman, E. L.
1975-01-01
The important features in a clinical system for quantitative angiography were examined. The human interface for data input, whether an electrostatic pen, sonic pen, or light-pen must be engineered to optimize the quality of margin definition. The computer programs which the technician uses for data entry and computation of ventriculographic measurements must be convenient to use on a routine basis in a laboratory performing multiple studies per day. The method used for magnification correction must be continuously monitored.
UMTRA Project water sampling and analysis plan, Durango, Colorado. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-09-01
Planned, routine ground water sampling activities at the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Durango, Colorado, are described in this water sampling and analysis plan. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine monitoring stations at the site. The ground water data are used to characterize the site ground water compliance strategies and to monitor contaminants of potential concern identified in the baseline risk assessment (DOE, 1995a). Regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from themore » US EPA regulations in 40 CFR Part 192 (1994) and EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site.« less
The Savannah River Site`s groundwater monitoring program. Third quarter 1990
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-05-06
The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site`s (SRS) Groundwater Monitoring Program. During third quarter 1990 (July through September) EPD/EMS conducted routine sampling of monitoring wells and drinking water locations. EPD/EMS established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead they aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, background levels in SRS groundwater, and drinking water standards. All analytical results from third quarter 1990 are listed in thismore » report, which is distributed to all site custodians. One or more analytes exceeded Flag 2 in 87 monitoring well series. Analytes exceeded Flat 2 for the first since 1984 in 14 monitoring well series. In addition to groundwater monitoring, EPD/EMS collected drinking water samples from SRS drinking water systems supplied by wells. The drinking water samples were analyzed for radioactive constituents.« less
The Savannah River Site's groundwater monitoring program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-05-06
The Environmental Protection Department/Environmental Monitoring Section (EPD/EMS) administers the Savannah River Site's (SRS) Groundwater Monitoring Program. During third quarter 1990 (July through September) EPD/EMS conducted routine sampling of monitoring wells and drinking water locations. EPD/EMS established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead they aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, background levels in SRS groundwater, and drinking water standards. All analytical results from third quarter 1990 are listed in thismore » report, which is distributed to all site custodians. One or more analytes exceeded Flag 2 in 87 monitoring well series. Analytes exceeded Flat 2 for the first since 1984 in 14 monitoring well series. In addition to groundwater monitoring, EPD/EMS collected drinking water samples from SRS drinking water systems supplied by wells. The drinking water samples were analyzed for radioactive constituents.« less
Paschoal, Fernando Mendes; de Almeida Lins Ronconi, Karla; de Lima Oliveira, Marcelo; Nogueira, Ricardo de Carvalho; Paschoal, Eric Homero Albuquerque; Teixeira, Manoel Jacobsen; Figueiredo, Eberval Gadelha; Bor-Seng-Shu, Edson
2015-01-01
Introduction. Cerebral emboli may occur in subarachnoid hemorrhage (SAH) and intracranial aneurysm surgery. Although embolic signs (ES) have been reported in SAH, their origin remains unclear. The aim of this study was to report the detection of ES during routine TCD monitoring in patients with aneurysmal SAH. Methods. A total of 105 patients with aneurysmal SAH were submitted to TCD evaluation. Patients were monitored almost daily (5 times per week). In each monitoring session, one experienced operator performed TCD to detect or assess vasospasm and ES in arteries of the Willis polygon. Results. Four patients out of a total of 105 patients with aneurysmal SAH were found to present spontaneous cerebral embolization during routine TCD monitoring. The average age of the 4 patients (mean ± standard deviation) was 59.5 ± 8.34 years (range 49–68 ys); female patients predominated representing 75% (3/4) of subjects. Conclusion. Although detection of ES was relatively rare in this study, rates of emboli occurrence may be higher under systematic monitoring. The detection of ES after SAH surgery reinforces the need to study the role of embolus in this condition and may be an indicator for prophylactic antithrombotic treatment. PMID:25893190
Telemetric implantable pressure sensor for short- and long-term monitoring of intracranial pressure.
Frischholz, M; Sarmento, L; Wenzel, M; Aquilina, K; Edwards, R; Coakham, H B
2007-01-01
Patients with hydrocephalus, idiopathic intracranial hypertension and head injury frequently require monitoring of intracranial pressure (ICP) and may need repeated episodes of monitoring months or years apart. The gold standard for measurement of ICP remains the external ventricular catheter. This is a fluid-filled catheter transducer system that allows regular recalibration and correction of zero drift by its position relative to a fixed anatomical reference. It also allows drainage of cerebrospinal fluid (CSF), providing a means of lowering the ICP. Several catheter tip transducer systems are currently in clinical use, including using strain gauges or fiber-optical pressure sensing techniques. In these devices, zero drift and calibration cannot be checked in vivo. All the ICP monitoring devices in current clinical use require a physical connection between the brain and the external environment. This is a source of infection and limits the duration of monitoring. A number of telemetric monitoring devices, in which data is in some way transmitted transcutaneously, have been developed over the last twenty years, but significant technical problems have precluded their use in routine clinical practice. All current ICP monitors are temporary percutaneous implanted devices. Placement of these devices carries significant morbidity, particularly infection. Patients undergoing repeated monitoring require multiple surgical procedures. Apart from decreasing the risk of infection in patients with severe head injury, the clinical value of an accurate telemetric ICP monitoring system which maintains its reliability over a long period of implantation is high.
Chaisson, R E; Barnes, G L; Hackman, J; Watkinson, L; Kimbrough , L; Metha, S; Cavalcante, S; Moore, R D
2001-06-01
To determine the effect of several interventions on adherence to tuberculosis preventive therapy. We conducted a randomized trial with a factorial design comparing strategies for improving adherence to isoniazid preventive therapy in 300 injection drug users with reactive tuberculin tests and no evidence of active tuberculosis. Patients were assigned to receive directly observed isoniazid preventive therapy twice weekly (Supervised group, n = 99), daily self-administered isoniazid with peer counseling and education (Peer group, n = 101), or routine care (Routine group, n = 100). Patients within each arm were also randomly assigned to receive an immediate or deferred monthly $10 stipend for maintaining adherence. The endpoints of the trial were completing 6 months of treatment, pill-taking as measured by self-report or observation, isoniazid metabolites present in urine, and bottle opening as determined by electronic monitors in a subset of patients. Completion of therapy was 80% for patients in the Supervised group, 78% in the Peer group, and 79% in the Routine group (P = 0.70). Completion was 83% (125 of 150) among patients receiving immediate incentives versus 75% (112 of 150) among patients with deferred incentives (P = 0.09). The proportion of patients who were observed or reported taking at least 80% of their doses was 82% for the Supervised arm of the study, compared with 71% for the Peer arm and 90% for the Routine arm. The proportion of patients who took 100% of doses was 77% for the Supervised arm (by observation), 6% for the Peer arm (by report), and 10% for the Routine arm (by report; P <0.001). Direct observation showed the median proportion of doses taken by the Supervised group was 100%, while electronic monitoring in a subset of patients showed the Peer group (n = 27) took 57% of prescribed doses and the Routine group (n = 32) took 49% (P <0.001). Patients in the Routine arm overreported adherence by twofold when data from electronic monitoring were used as a gold standard. There were no significant differences in electronically monitored adherence by type of incentive. Adherence to isoniazid preventive therapy by injection drug users is best with supervised care. Peer counseling improves adherence over routine care, as measured by electronic monitoring of pill caps, and patients receiving peer counseling more accurately reported their adherence. More widespread use of supervised care could contribute to reductions in tuberculosis rates among drug users and possibly other high-risk groups.
NASA Astrophysics Data System (ADS)
Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Perkov, A.; Sasyuk, V.
2016-12-01
Here we present the summary of first years of operation and the first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-Mega-TORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (˜900 square degrees) or narrow (˜100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds. The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT include faint meteors and artificial satellites. The pipeline for a longer time scales variability analysis is still in development.
NASA Astrophysics Data System (ADS)
Karpov, S.; Beskin, G.; Biryukov, A.; Bondar, S.; Ivanov, E.; Katkova, E.; Perkov, A.; Sasyuk, V.
2016-06-01
Here we present a summary of first years of operation and first results of a novel 9-channel wide-field optical monitoring system with sub-second temporal resolution, Mini-MegaTORTORA (MMT-9), which is in operation now at Special Astrophysical Observatory on Russian Caucasus. The system is able to observe the sky simultaneously in either wide (~900 square degrees) or narrow (~100 square degrees) fields of view, either in clear light or with any combination of color (Johnson-Cousins B, V or R) and polarimetric filters installed, with exposure times ranging from 0.1 s to hundreds of seconds. The real-time system data analysis pipeline performs automatic detection of rapid transient events, both near-Earth and extragalactic. The objects routinely detected by MMT include faint meteors and artificial satellites. The pipeline for a longer time scales variability analysis is still in development.
Seelye, Adriana; Mattek, Nora; Sharma, Nicole; Witter, Phelps; Brenner, Ariella; Wild, Katherine; Dodge, Hiroko; Kaye, Jeffrey
2017-01-01
Background Driving is a key functional activity for many older adults, and changes in routine driving may be associated with emerging cognitive decline due to early neurodegenerative disease. Current methods for assessing driving such as self-report are inadequate for identifying and monitoring subtle changes in driving patterns that may be the earliest signals of functional change in developing mild cognitive impairment (MCI). Objective This proof of concept study aimed to establish the feasibility of continuous driving monitoring in a sample of cognitively normal and MCI older adults for an average of 206 days using an unobtrusive driving sensor and demonstrate that derived sensor-based driving metrics could effectively discriminate between MCI and cognitively intact groups. Methods Novel objective driving measures derived from 6 months of routine driving monitoring were examined in older adults with intact cognition (n = 21) and MCI (n = 7) who were enrolled in the Oregon Center for Aging and Technology (ORCATECH) longitudinal assessment program. Results Unobtrusive continuous monitoring of older adults’ routine driving using a driving sensor was feasible and well accepted. MCI participants drove fewer miles and spent less time on the highway per day than cognitively intact participants. MCI drivers showed less day-to-day fluctuations in their driving habits than cognitively intact drivers. Conclusion Sensor-based driving measures are objective, unobtrusive, and can be assessed every time a person drives his or her vehicle to identify clinically meaningful changes in daily driving. This novel methodology has the potential to be useful for the early detection and monitoring of changes in daily functioning within individuals. PMID:28731434
Aerosol Chemical Speciation Monitor (ACSM) Instrument Handbook
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watson, Thomas B.
The Aerodyne Aerosol Chemical Speciation Monitor (ACSM) measures particle mass loading and chemical composition in real time for non-refractory sub-micron aerosol particles. The ACSM is designed for long-term unattended deployment and routine monitoring applications.
Enabling affordable and efficiently deployed location based smart home systems.
Kelly, Damian; McLoone, Sean; Dishongh, Terry
2009-01-01
With the obvious eldercare capabilities of smart environments it is a question of "when", rather than "if", these technologies will be routinely integrated into the design of future houses. In the meantime, health monitoring applications must be integrated into already complete home environments. However, there is significant effort involved in installing the hardware necessary to monitor the movements of an elder throughout an environment. Our work seeks to address the high infrastructure requirements of traditional location-based smart home systems by developing an extremely low infrastructure localisation technique. A study of the most efficient method of obtaining calibration data for an environment is conducted and different mobile devices are compared for localisation accuracy and cost trade-off. It is believed that these developments will contribute towards more efficiently deployed location-based smart home systems.
Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei
2011-02-01
Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Schwartz, Frank L; Vernier, Stanley J; Shubrook, Jay H; Marling, Cynthia R
2010-11-01
We have developed a prototypical case-based reasoning system to enhance management of patients with type 1 diabetes mellitus (T1DM). The system is capable of automatically analyzing large volumes of life events, self-monitoring of blood glucose readings, continuous glucose monitoring system results, and insulin pump data to detect clinical problems. In a preliminary study, manual entry of large volumes of life-event and other data was too burdensome for patients. In this study, life-event and pump data collection were automated, and then the system was reevaluated. Twenty-three adult T1DM patients on insulin pumps completed the five-week study. A usual daily schedule was entered into the database, and patients were only required to upload their insulin pump data to Medtronic's CareLink® Web site weekly. Situation assessment routines were run weekly for each participant to detect possible problems, and once the trial was completed, the case-retrieval module was tested. Using the situation assessment routines previously developed, the system found 295 possible problems. The enhanced system detected only 2.6 problems per patient per week compared to 4.9 problems per patient per week in the preliminary study (p=.017). Problems detected by the system were correctly identified in 97.9% of the cases, and 96.1% of these were clinically useful. With less life-event data, the system is unable to detect certain clinical problems and detects fewer problems overall. Additional work is needed to provide device/software interfaces that allow patients to provide this data quickly and conveniently. © 2010 Diabetes Technology Society.
AUTOMATED RADIOLOGICAL MONITORING AT A RUSSIAN MINISTRY OF DEFENCE NAVAL SITE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MOSKOWITZ,P.D.; POMERVILLE,J.; GAVRILOV,S.
2001-02-25
The Arctic Military Environmental Cooperation (AMEC) Program is a cooperative effort between the military establishments of the Kingdom of Norway, the Russian Federation, and the US. This paper discusses joint activities conducted over the past year among Norwegian, Russian, and US technical experts on a project to develop, demonstrate and implement automated radiological monitoring at Russian Navy facilities engaged in the dismantlement of nuclear-powered strategic ballistic missile launching submarines. Radiological monitoring is needed at these facilities to help protect workers engaged in the dismantlement program and the public living within the footprint of routine and accidental radiation exposure areas. Bymore » providing remote stand-alone monitoring, the Russian Navy will achieve added protection due to the defense-in-depth strategy afforded by local (at the site), regional (Kola) and national-level (Moscow) oversight. The system being implemented at the Polyaminsky Russian Naval Shipyard was developed from a working model tested at the Russian Institute for Nuclear Safety, Moscow, Russia. It includes Russian manufactured terrestrial and underwater gamma detectors, smart controllers for graded sampling, radio-modems for offsite transmission of the data, and a data fusion/display system: The data fusion/display system is derived from the Norwegian Picasso AMEC Environmental Monitoring software package. This computer package allows monitoring personnel to review the real-time and historical status of monitoring at specific sites and objects and to establish new monitoring protocols as required, for example, in an off-normal accident situation. Plans are being developed to implement the use of this system at most RF Naval sites handling spent nuclear fuel.« less
AUTOMATED RADIOLOGICAL MONITORING AT A RUSSIAN MINISTRY OF DEFENSE NAVAL SITE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
MOSKOWITZ,P.D.; POMERVILLE,J.; GAVRILOV,S.
2001-02-25
The Arctic Military Environmental Cooperation (AMEC) Program is a cooperative effort between the military establishments of the Kingdom of Norway, the Russian Federation, and the US. This paper discusses joint activities conducted over the past year among Norwegian, Russian, and US technical experts on a project to develop, demonstrate and implement automated radiological monitoring at Russian Navy facilities engaged in the dismantlement of nuclear-powered strategic ballistic missile launching submarines. Radiological monitoring is needed at these facilities to help protect workers engaged in the dismantlement program and the public living within the footprint of routine and accidental radiation exposure areas. Bymore » providing remote stand-alone monitoring, the Russian Navy will achieve added protection due to the defense-in-depth strategy afforded by local (at the site), regional (Kola) and national-level (Moscow) oversight. The system being implemented at the Polyaminsky Russian Naval Shipyard was developed from a working model tested at the Russian Institute for Nuclear Safety, Moscow, Russia. It includes Russian manufactured terrestrial and underwater gamma detectors, smart controllers for graded sampling, radio-modems for offsite transmission of the data, and a data fusion/display system: The data fusion/display system is derived from the Norwegian Picasso AMEC Environmental Monitoring software package. This computer package allows monitoring personnel to review the real-time and historical status of monitoring at specific sites and objects and to establish new monitoring protocols as required, for example, in an off-normal accident situation. Plans are being developed to implement the use of this system at most RF Naval sites handling spent nuclear fuel.« less
A Review of Diagnostic Techniques for ISHM Applications
NASA Technical Reports Server (NTRS)
Patterson-Hine, Ann; Biswas, Gautam; Aaseng, Gordon; Narasimhan, Sriam; Pattipati, Krishna
2005-01-01
System diagnosis is an integral part of any Integrated System Health Management application. Diagnostic applications make use of system information from the design phase, such as safety and mission assurance analysis, failure modes and effects analysis, hazards analysis, functional models, fault propagation models, and testability analysis. In modern process control and equipment monitoring systems, topological and analytic , models of the nominal system, derived from design documents, are also employed for fault isolation and identification. Depending on the complexity of the monitored signals from the physical system, diagnostic applications may involve straightforward trending and feature extraction techniques to retrieve the parameters of importance from the sensor streams. They also may involve very complex analysis routines, such as signal processing, learning or classification methods to derive the parameters of importance to diagnosis. The process that is used to diagnose anomalous conditions from monitored system signals varies widely across the different approaches to system diagnosis. Rule-based expert systems, case-based reasoning systems, model-based reasoning systems, learning systems, and probabilistic reasoning systems are examples of the many diverse approaches ta diagnostic reasoning. Many engineering disciplines have specific approaches to modeling, monitoring and diagnosing anomalous conditions. Therefore, there is no "one-size-fits-all" approach to building diagnostic and health monitoring capabilities for a system. For instance, the conventional approaches to diagnosing failures in rotorcraft applications are very different from those used in communications systems. Further, online and offline automated diagnostic applications are integrated into an operations framework with flight crews, flight controllers and maintenance teams. While the emphasis of this paper is automation of health management functions, striking the correct balance between automated and human-performed tasks is a vital concern.
Murphy, Debra A.; Marelich, William D.; Herbeck, Diane M.; Payne, Diana L.
2011-01-01
The influence of parenting skills on adolescent outcomes among children affected by maternal HIV/AIDS (N = 118, M age = 13) was investigated. Among families with more frequent family routines, over time adolescents showed lower rates of aggression, anxiety, worry, depression, conduct disorder, binge drinking, and increased self-concept. Among families with higher levels of parental monitoring, adolescents showed significant declines in anxiety and depression, conduct disorder, and binge drinking, along with increased self-concept. Mothers’ level of illness was associated with parenting. Greater variability in parental monitoring resulted in higher levels of problem behaviors. PMID:19930345
Kotter, Elmar; Bley, Thorsten A; Saueressig, Ulrich; Fisch, Dagmar; Springer, Oliver; Winterer, Jan Torsten; Schaefer, Oliver; Langer, Mathias
2003-11-01
To evaluate the detection rate of fine details of a new thin-film transistor (TFT) grayscale monitor designed for radiologic diagnosis, compared with a type of cathode ray tube (CRT) screen used routinely for diagnostic radiology. Fifteen radiographs of a statistical phantom presenting low- and high-contrast details were obtained and read out with an Agfa ADC compact storage phosphor system. Each radiograph presented 60 high-density (high-contrast) and 60 low-density (low-contrast) test bodies. Approximately half the test bodies contained holes with different diameters. Observers were asked to detect the presence or absence of a hole in the test body on a 5-point confidence range. The total of 1800 test bodies was reviewed by 5 radiologists on the TFT monitor (20.8 inches; 1536 x 2048 pixels; maximum luminance, 650 cd/m2; contrast, 600:1) and the CRT monitor (21 inches; P45 Phosphor; 2048 x 2560 pixels operated at 1728 x 2304 pixels; maximum luminance, 600 cd/m2; contrast, 300:1). The data were analyzed by receiver-operator characteristic analysis. For high-contrast details, the mean area under the curve rated 0.9336 for the TFT monitor and 0.9312 for the CRT monitor. For low-contrast details, the mean area under the curve rated 0.9189 for the TFT monitor and 0.9224 for the CRT monitor. At P
Use of Semi-Autonomous Tools for ISS Commanding and Monitoring
NASA Technical Reports Server (NTRS)
Brzezinski, Amy S.
2014-01-01
As the International Space Station (ISS) has moved into a utilization phase, operations have shifted to become more ground-based with fewer mission control personnel monitoring and commanding multiple ISS systems. This shift to fewer people monitoring more systems has prompted use of semi-autonomous console tools in the ISS Mission Control Center (MCC) to help flight controllers command and monitor the ISS. These console tools perform routine operational procedures while keeping the human operator "in the loop" to monitor and intervene when off-nominal events arise. Two such tools, the Pre-positioned Load (PPL) Loader and Automatic Operators Recorder Manager (AutoORM), are used by the ISS Communications RF Onboard Networks Utilization Specialist (CRONUS) flight control position. CRONUS is responsible for simultaneously commanding and monitoring the ISS Command & Data Handling (C&DH) and Communications and Tracking (C&T) systems. PPL Loader is used to uplink small pieces of frequently changed software data tables, called PPLs, to ISS computers to support different ISS operations. In order to uplink a PPL, a data load command must be built that contains multiple user-input fields. Next, a multiple step commanding and verification procedure must be performed to enable an onboard computer for software uplink, uplink the PPL, verify the PPL has incorporated correctly, and disable the computer for software uplink. PPL Loader provides different levels of automation in both building and uplinking these commands. In its manual mode, PPL Loader automatically builds the PPL data load commands but allows the flight controller to verify and save the commands for future uplink. In its auto mode, PPL Loader automatically builds the PPL data load commands for flight controller verification, but automatically performs the PPL uplink procedure by sending commands and performing verification checks while notifying CRONUS of procedure step completion. If an off-nominal condition occurs during procedure execution, PPL Loader notifies CRONUS through popup messages, allowing CRONUS to examine the situation and choose an option of how PPL loader should proceed with the procedure. The use of PPL Loader to perform frequent, routine PPL uplinks offloads CRONUS to better monitor two ISS systems. It also reduces procedure performance time and decreases risk of command errors. AutoORM identifies ISS communication outage periods and builds commands to lock, playback, and unlock ISS Operations Recorder files. Operation Recorder files are circular buffer files of continually recorded ISS telemetry data. Sections of these files can be locked from further writing, be played back to capture telemetry data that occurred during an ISS loss of signal (LOS) period, and then be unlocked for future recording use. Downlinked Operation Recorder files are used by mission support teams for data analysis, especially if failures occur during LOS. The commands to lock, playback, and unlock Operations Recorder files are encompassed in three different operational procedures and contain multiple user-input fields. AutoORM provides different levels of automation for building and uplinking the commands to lock, playback, and unlock Operations Recorder files. In its automatic mode, AutoORM automatically detects ISS LOS periods, then generates and uplinks the commands to lock, playback, and unlock Operations Recorder files when MCC regains signal with ISS. AutoORM also features semi-autonomous and manual modes which integrate CRONUS more into the command verification and uplink process. AutoORMs ability to automatically detect ISS LOS periods and build the necessary commands to preserve, playback, and release recorded telemetry data greatly offloads CRONUS to perform more high-level cognitive tasks, such as mission planning and anomaly troubleshooting. Additionally, since Operations Recorder commands contain numerical time input fields which are tedious for a human to manually build, AutoORM's ability to automatically build commands reduces operational command errors. PPL Loader and AutoORM demonstrate principles of semi-autonomous operational tools that will benefit future space mission operations. Both tools employ different levels of automation to perform simple and routine procedures, thereby offloading human operators to perform higher-level cognitive tasks. Because both tools provide procedure execution status and highlight off-nominal indications, the flight controller is able to intervene during procedure execution if needed. Semi-autonomous tools and systems that can perform routine procedures, yet keep human operators informed of execution, will be essential in future long-duration missions where the onboard crew will be solely responsible for spacecraft monitoring and control.
Peer-Monitoring and Self-Monitoring: Alternatives to Traditional Teacher Management.
ERIC Educational Resources Information Center
Fowler, Susan A.
1986-01-01
Peer-monitoring and self-monitoring procedures were developed to decrease disruption and nonparticipation during transition activities of a kindergarten class with 10 children with behavior and/or learning problems. Results suggested that classroom management can be achieved through carefully developed routines with clear instructions paired with…
Bedini, José Luis; Wallace, Jane F; Pardo, Scott; Petruschke, Thorsten
2015-10-07
Blood glucose monitoring is an essential component of diabetes management. Inaccurate blood glucose measurements can severely impact patients' health. This study evaluated the performance of 3 blood glucose monitoring systems (BGMS), Contour® Next USB, FreeStyle InsuLinx®, and OneTouch® Verio™ IQ, under routine hospital conditions. Venous blood samples (N = 236) obtained for routine laboratory procedures were collected at a Spanish hospital, and blood glucose (BG) concentrations were measured with each BGMS and with the available reference (hexokinase) method. Accuracy of the 3 BGMS was compared according to ISO 15197:2013 accuracy limit criteria, by mean absolute relative difference (MARD), consensus error grid (CEG) and surveillance error grid (SEG) analyses, and an insulin dosing error model. All BGMS met the accuracy limit criteria defined by ISO 15197:2013. While all measurements of the 3 BGMS were within low-risk zones in both error grid analyses, the Contour Next USB showed significantly smaller MARDs between reference values compared to the other 2 BGMS. Insulin dosing errors were lowest for the Contour Next USB than compared to the other systems. All BGMS fulfilled ISO 15197:2013 accuracy limit criteria and CEG criterion. However, taking together all analyses, differences in performance of potential clinical relevance may be observed. Results showed that Contour Next USB had lowest MARD values across the tested glucose range, as compared with the 2 other BGMS. CEG and SEG analyses as well as calculation of the hypothetical bolus insulin dosing error suggest a high accuracy of the Contour Next USB. © 2015 Diabetes Technology Society.
Dantas, B M; Lucena, E A; Dantas, A L A; Santos, M S; Julião, L Q C; Melo, D R; Sousa, W O; Fernandes, P C; Mesquita, S A
2010-10-01
Internal exposures may occur in nuclear power plants, radioisotope production, and in medicine and research laboratories. Such practices require quick response in case of accidents of a wide range of magnitudes. This work presents the design and calibration of a mobile laboratory for the assessment of accidents involving workers and the population as well as for routine monitoring. The system was set up in a truck with internal dimensions of 3.30 m × 1.60 m × 1.70 m and can identify photon emitters in the energy range of 100-3,000 keV in the whole body, organs, and in urine. A thyroid monitor consisting of a lead-collimated NaI(Tl)3" × 3" (7.62 × 7.62 cm) detector was calibrated with a neck-thyroid phantom developed at the IRD (Instituto de Radioproteção e Dosimetria). Whole body measurements were performed with a NaI(Tl)8" × 4" (20.32 × 10.16 cm) detector calibrated with a plastic-bottle phantom. Urine samples were measured with another NaI(Tl) 3" × 3" (7.62 × 7.62 cm) detector set up in a steel support. Standard solutions were provided by the National Laboratory for Metrology of Ionizing Radiation of the IRD. Urine measurements are based on a calibration of efficiency vs. energy for standard volumes. Detection limits were converted to minimum committed effective doses for the radionuclides of interest using standard biokinetic and dosimetric models in order to evaluate the applicability and limitations of the system. Sensitivities for high-energy activation and fission products show that the system is suitable for use in emergency and routine monitoring of individuals under risk of internal exposure by such radionuclides.
van Kasteren, Yasmin; Bradford, Dana; Zhang, Qing; Karunanithi, Mohan; Ding, Hang
2017-06-13
An ongoing challenge for smart homes research for aging-in-place is how to make sense of the large amounts of data from in-home sensors to facilitate real-time monitoring and develop reliable alerts. The objective of our study was to explore the usefulness of a routine-based approach for making sense of smart home data for the elderly. Maximum variation sampling was used to select three cases for an in-depth mixed methods exploration of the daily routines of three elderly participants in a smart home trial using 180 days of power use and motion sensor data and longitudinal interview data. Sensor data accurately matched self-reported routines. By comparing daily movement data with personal routines, it was possible to identify changes in routine that signaled illness, recovery from bereavement, and gradual deterioration of sleep quality and daily movement. Interview and sensor data also identified changes in routine with variations in temperature and daylight hours. The findings demonstrated that a routine-based approach makes interpreting sensor data easy, intuitive, and transparent. They highlighted the importance of understanding and accounting for individual differences in preferences for routinization and the influence of the cyclical nature of daily routines, social or cultural rhythms, and seasonal changes in temperature and daylight hours when interpreting information based on sensor data. This research has demonstrated the usefulness of a routine-based approach for making sense of smart home data, which has furthered the understanding of the challenges that need to be addressed in order to make real-time monitoring and effective alerts a reality. ©Yasmin van Kasteren, Dana Bradford, Qing Zhang, Mohan Karunanithi, Hang Ding. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 13.06.2017.
van Kasteren, Yasmin; Bradford, Dana; Karunanithi, Mohan; Ding, Hang
2017-01-01
Background An ongoing challenge for smart homes research for aging-in-place is how to make sense of the large amounts of data from in-home sensors to facilitate real-time monitoring and develop reliable alerts. Objective The objective of our study was to explore the usefulness of a routine-based approach for making sense of smart home data for the elderly. Methods Maximum variation sampling was used to select three cases for an in-depth mixed methods exploration of the daily routines of three elderly participants in a smart home trial using 180 days of power use and motion sensor data and longitudinal interview data. Results Sensor data accurately matched self-reported routines. By comparing daily movement data with personal routines, it was possible to identify changes in routine that signaled illness, recovery from bereavement, and gradual deterioration of sleep quality and daily movement. Interview and sensor data also identified changes in routine with variations in temperature and daylight hours. Conclusions The findings demonstrated that a routine-based approach makes interpreting sensor data easy, intuitive, and transparent. They highlighted the importance of understanding and accounting for individual differences in preferences for routinization and the influence of the cyclical nature of daily routines, social or cultural rhythms, and seasonal changes in temperature and daylight hours when interpreting information based on sensor data. This research has demonstrated the usefulness of a routine-based approach for making sense of smart home data, which has furthered the understanding of the challenges that need to be addressed in order to make real-time monitoring and effective alerts a reality. PMID:28611014
Piot, Bram; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-01-01
Objectives This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. Methods The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. Results A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. Conclusion LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets. PMID:20167732
Piot, Bram; Mukherjee, Amajit; Navin, Deepa; Krishnan, Nattu; Bhardwaj, Ashish; Sharma, Vivek; Marjara, Pritpal
2010-02-01
This study reports on the results of a large-scale targeted condom social marketing campaign in and around areas where female sex workers are present. The paper also describes the method that was used for the routine monitoring of condom availability in these sites. The lot quality assurance sampling (LQAS) method was used for the assessment of the geographical coverage and quality of coverage of condoms in target areas in four states and along selected national highways in India, as part of Avahan, the India AIDS initiative. A significant general increase in condom availability was observed in the intervention area between 2005 and 2008. High coverage rates were gradually achieved through an extensive network of pharmacies and particularly of non-traditional outlets, whereas traditional outlets were instrumental in providing large volumes of condoms. LQAS is seen as a valuable tool for the routine monitoring of the geographical coverage and of the quality of delivery systems of condoms and of health products and services in general. With a relatively small sample size, easy data collection procedures and simple analytical methods, it was possible to inform decision-makers regularly on progress towards coverage targets.
The chimpanzee as a flight candidate. [for cardiovascular studies
NASA Technical Reports Server (NTRS)
1977-01-01
Some of the characteristics that make the chimpanzee an attractive animal model (anatomy, size, intelligence, and durability) also create some very unique problems. The universally recognized problems of availability and expensive maintenance, combined with the often underestimated problems associated with routine housing, husbandry, restraint, and medical management, severely limit the availabe avenues of approach. Problems involved in using implantable, multichannel radiotelemetry systems to monitor cardiodynamics in chimpanzees are discussed.
Automation-induced monitoring inefficiency: role of display location.
Singh, I L; Molloy, R; Parasuraman, R
1997-01-01
Operators can be poor monitors of automation if they are engaged concurrently in other tasks. However, in previous studies of this phenomenon the automated task was always presented in the periphery, away from the primary manual tasks that were centrally displayed. In this study we examined whether centrally locating an automated task would boost monitoring performance during a flight-simulation task consisting of system monitoring, tracking and fuel resource management sub-tasks. Twelve nonpilot subjects were required to perform the tracking and fuel management tasks manually while watching the automated system monitoring task for occasional failures. The automation reliability was constant at 87.5% for six subjects and variable (alternating between 87.5% and 56.25%) for the other six subjects. Each subject completed four 30 min sessions over a period of 2 days. In each automation reliability condition the automation routine was disabled for the last 20 min of the fourth session in order to simulate catastrophic automation failure (0 % reliability). Monitoring for automation failure was inefficient when automation reliability was constant but not when it varied over time, replicating previous results. Furthermore, there was no evidence of resource or speed accuracy trade-off between tasks. Thus, automation-induced failures of monitoring cannot be prevented by centrally locating the automated task.
Automation-induced monitoring inefficiency: role of display location
NASA Technical Reports Server (NTRS)
Singh, I. L.; Molloy, R.; Parasuraman, R.
1997-01-01
Operators can be poor monitors of automation if they are engaged concurrently in other tasks. However, in previous studies of this phenomenon the automated task was always presented in the periphery, away from the primary manual tasks that were centrally displayed. In this study we examined whether centrally locating an automated task would boost monitoring performance during a flight-simulation task consisting of system monitoring, tracking and fuel resource management sub-tasks. Twelve nonpilot subjects were required to perform the tracking and fuel management tasks manually while watching the automated system monitoring task for occasional failures. The automation reliability was constant at 87.5% for six subjects and variable (alternating between 87.5% and 56.25%) for the other six subjects. Each subject completed four 30 min sessions over a period of 2 days. In each automation reliability condition the automation routine was disabled for the last 20 min of the fourth session in order to simulate catastrophic automation failure (0 % reliability). Monitoring for automation failure was inefficient when automation reliability was constant but not when it varied over time, replicating previous results. Furthermore, there was no evidence of resource or speed accuracy trade-off between tasks. Thus, automation-induced failures of monitoring cannot be prevented by centrally locating the automated task.
Xia, Jianhong; Rutherford, Shannon; Ma, Yuanzhu; Wu, Li; Gao, Shuang; Chen, Tingting; Lu, Xiao; Zhang, Xiaozhuang; Chu, Cordia
2015-03-24
Integration of services for Prevention of Mother-To-Child Transmission of HIV (PMTCT) into routine maternal and child health care is promoted as a priority strategy by the WHO to facilitate the implementation of PMTCT. Integration of services emphasizes inter-sectoral coordination in the health systems to provide convenient services for clients. China has been integrating prenatal HIV, syphilis and hepatitis B testing services since 2009. However, as the individual health systems are complex, effective coordination among different health agencies is challenging. Few studies have examined the factors that affect the coordination of such complex systems. The aim of this study is to assess the effectiveness of and examine challenges for integrated service delivery. Findings will provide the basis for strategy development to enhance the effective delivery of integrated services. The research was conducted in Guangdong province in 2013 using a needs assessment approach that includes qualitative and quantitative methods. Quantitative data was collected through a survey and from routine monitoring for PMTCT and qualitative data was collected through stakeholder interviews. Routine monitoring data used to assess key indicators of coordination suggested numerous coordination problems. The rates of prenatal HIV (95%), syphilis (47%) and hepatitis B (47%) test were inconsistent. An average of only 20% of the HIV positive mothers was referred in the health systems. There were no regular meetings among different health agencies and the clients indicated complicated service processes. The major obstacles to the coordination of delivering these integrated services are lack of service resource integration; and lack of a mechanism for coordination of the health systems, with no uniform guidelines, clear roles or consistent evaluation. The key obstacles that have been identified in this study hinder the coordination of the delivery of integrated services. Our recommendations include: 1) Facilitate integration of the funding and information systems by fully combining the service resources of different health agencies into one unit; 2) Establish regular meetings to facilitate exchange of information and address problems; 3) Establish a client referral network between different health agencies with agreed guidelines, clear roles and consistent evaluation.
User Interactive Software for Analysis of Human Physiological Data
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Toscano, William; Taylor, Bruce C.; Acharya, Soumydipta
2006-01-01
Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration
Monitoring Artificial Pancreas Trials Through Agent-based Technologies
Scarpellini, Stefania; Di Palma, Federico; Toffanin, Chiara; Del Favero, Simone; Magni, Lalo; Bellazzi, Riccardo
2014-01-01
The increase in the availability and reliability of network connections lets envision systems supporting a continuous remote monitoring of clinical parameters useful either for overseeing chronic diseases or for following clinical trials involving outpatients. We report here the results achieved by a telemedicine infrastructure that has been linked to an artificial pancreas platform and used during a trial of the AP@home project, funded by the European Union. The telemedicine infrastructure is based on a multiagent paradigm and is able to deliver to the clinic any information concerning the patient status and the operation of the artificial pancreas. A web application has also been developed, so that the clinic staff and the researchers involved in the design of the blood glucose control algorithms are able to follow the ongoing experiments. Albeit the duration of the experiments in the trial discussed in the article was limited to only 2 days, the system proved to be successful for monitoring patients, in particular overnight when the patients are sleeping. Based on that outcome we can conclude that the infrastructure is suitable for the purpose of accomplishing an intelligent monitoring of an artificial pancreas either during longer trials or whenever that system will be used as a routine treatment. PMID:24876570
NASA Astrophysics Data System (ADS)
Chen, Y.; Ni, Y. Q.; Ye, X. W.; Yang, H. X.; Zhu, S.
2012-04-01
Wind energy utilization as a reliable energy source has become a large industry in the last 20 years. Nowadays, wind turbines can generate megawatts of power and have rotor diameters that are on the order of 100 meters in diameter. One of the key components in a wind turbine is the blade which could be damaged by moisture absorption, fatigue, wind gusts or lighting strikes. The wind turbine blades should be routinely monitored to improve safety, minimize downtime, lower the risk of sudden breakdowns and associated huge maintenance and logistics costs, and provide reliable power generation. In this paper, a real-time wind turbine blade monitoring system using fiber Bragg grating (FBG) sensors with the fiber optic rotary joint (FORJ) is proposed, and applied to monitor the structural responses of a 600 W small scale wind turbine. The feasibility and effectiveness of the FORJ is validated by continuously transmitting the optical signals between the FBG interrogator at the stationary side and the FBG sensors on the rotating part. A comparison study between the measured data from the proposed system and those from an IMote2-based wireless strain measurement system is conducted.
Nash, Denis; Elul, Batya; Rabkin, Miriam; Tun, May; Saito, Suzue; Becker, Mark; Nuwagaba-Biribonwoha, Harriet
2009-11-01
Program monitoring and evaluation (M&E) has the potential to be a cornerstone of health systems strengthening and of evidence-informed implementation and scale-up of HIV-related services in resource-limited settings. We discuss common challenges to M&E systems used in the rapid scale-up of HIV services as well as innovations that may have relevance to systems used to monitor, evaluate, and inform health systems strengthening. These include (1) Web-based applications with decentralized data entry and real-time access to summary reporting; (2) timely feedback of information to site and district staff; (3) site-level integration of traditionally siloed program area indicators; (4) longitudinal tracking of program and site characteristics; (5) geographic information systems; and (6) use of routinely collected aggregate data for epidemiologic analysis and operations research. Although conventionally used in the context of vertical programs, these approaches can form a foundation on which data relevant to other health services and systems can be layered, including prevention services, primary care, maternal-child health, and chronic disease management. Guiding principles for sustainable national M&E systems include country-led development and ownership, support for national programs and policies, interoperability, and employment of an open-source approach to software development.
Home geriatric physiological measurements.
Tamura, Toshiyo
2012-10-01
In an ageing society, the elderly can be monitored with numerous physiological, physical and passive devices. Sensors can be installed in the home for continuous mobility assistance and unobtrusive disease prevention. This review presents several modern sensors, which improve the quality of life and assist the elderly, disabled people and their caregivers. The main concept of geriatric sensors is that they are capable of providing assistance without limiting or disturbing the subject's daily routine, giving him or her greater comfort, pleasure and well-being. Furthermore, this review includes associated technologies of wearable/implantable monitoring systems and the 'smart-house' project. This review concludes by discussing future challenges of the future aged society.
Rotheram-Borus, Mary Jane; Le Roux, Karl; Le Roux, Ingrid M; Christodoulou, Joan; Laurenzi, Christina; Mbewu, Nokwanele; Tomlinson, Mark
2017-08-07
Concurrent epidemics of HIV, depression, alcohol abuse, and partner violence threaten maternal and child health (MCH) in South Africa. Although home visiting has been repeatedly demonstrated efficacious in research evaluations, efficacy disappears when programs are scaled broadly. In this cluster randomized controlled trial (RCT), we examine whether the benefits of ongoing accountability and supervision within an existing government funded and implemented community health workers (CHW) home visiting program ensure the effectiveness of home visiting. In the deeply rural, Eastern Cape of South Africa, CHW will be hired by the government and will be initially trained by the Philani Programme to conduct home visits with all pregnant mothers and their children until the children are 2 years old. Eight clinics will be randomized to receive either (1) the Accountable Care Condition in which additional monitoring and accountability systems that Philani routinely uses are implemented (4 clinics, 16 CHW, 450 households); or (2) a Standard Care Condition of initial Philani training, but with supervision and monitoring being delivered by local government structures and systems (4 clinics, 21 CHW, 450 households). In the Accountable Care Condition areas, the CHW's mobile phone reports, which are time-location stamped, will be monitored and data-informed supervision will be provided, as well as monitoring growth, medical adherence, mental health, and alcohol use outcomes. Interviewers will independently assess outcomes at pregnancy at 3, 6, 15, and 24 months post-birth. The primary outcome will be a composite score of documenting maternal HIV/TB testing, linkage to care, treatment adherence and retention, as well as child physical growth, cognitive functioning, and child behavior and developmental milestones. The proposed cluster RCT will evaluate whether routinely implementing supervision and accountability procedures and monitoring CHWs' over time will improve MCH outcomes over the first 2 years of life. ClinicalTrials.gov registration #NCT02957799 , registered on October 26, 2016.
Improved Heat-Stress Algorithm
NASA Technical Reports Server (NTRS)
Teets, Edward H., Jr.; Fehn, Steven
2007-01-01
NASA Dryden presents an improved and automated site-specific algorithm for heat-stress approximation using standard atmospheric measurements routinely obtained from the Edwards Air Force Base weather detachment. Heat stress, which is the net heat load a worker may be exposed to, is officially measured using a thermal-environment monitoring system to calculate the wet-bulb globe temperature (WBGT). This instrument uses three independent thermometers to measure wet-bulb, dry-bulb, and the black-globe temperatures. By using these improvements, a more realistic WBGT estimation value can now be produced. This is extremely useful for researchers and other employees who are working on outdoor projects that are distant from the areas that the Web system monitors. Most importantly, the improved WBGT estimations will make outdoor work sites safer by reducing the likelihood of heat stress.
Development and Implementation of Sepsis Alert Systems.
Harrison, Andrew M; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly
2016-06-01
Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload, and alert fatigue, due to suboptimal alert performance. Outside the ICU, barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Current evidence does not support routine use of sepsis alert systems in clinical practice. Continuous improvement in the afferent and efferent aspects will help translate theoretic advantages into measurable patient benefit. Copyright © 2016 Elsevier Inc. All rights reserved.
Clinical applications of MS-based protein quantification.
Sabbagh, Bassel; Mindt, Sonani; Neumaier, Michael; Findeisen, Peter
2016-04-01
Mass spectrometry-based assays are increasingly important in clinical laboratory medicine and nowadays are already commonly used in several areas of routine diagnostics. These include therapeutic drug monitoring, toxicology, endocrinology, pediatrics, and microbiology. Accordingly, some of the most common analyses are therapeutic drug monitoring of immunosuppressants, vitamin D, steroids, newborn screening, and bacterial identification. However, MS-based quantification of peptides and proteins for routine diagnostic use is rather rare up to now despite excellent analytical specificity and good sensitivity. Here, we want to give an overview over current fit-for-purpose assays for MS-based protein quantification. Advantages as well as challenges of this approach will be discussed with focus on feasibility for routine diagnostic use. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Salinas, Maria; López-Garrigós, Maite; Santo-Quiles, Ana; Gutierrez, Mercedes; Lugo, Javier; Lillo, Rosa; Leiva-Salinas, Carlos
2014-09-01
The purpose of this study is, first to present a 10-year monitoring of postanalytical turnaround time (TAT) adapted to different clinicians and patient situations, second to evaluate and analyse the indicators results during that period of time, and finally to show a synthetic appropriate indicator to be included in the balanced scorecard management system. TAT indicator for routine samples was devised as the percentage of certain key tests that were verified before a specific time on the phlebotomy day. A weighted mean synthetic indicator was also designed. They were calculated for inpatients at 15:00 and 12:00 and for primary care patients only at 15:00. The troponin TAT of emergency department patients, calculated as the difference between the troponin verification and registration time, was selected as the stat laboratory TAT indicator. The routine and stat TAT improved along the 10-year study period. The synthetic indicator showed the same trend. The implementation of systematic and continuous monitoring over years, promoted a continuous improvement in TAT which will probably benefit patient outcome and safety.
Economic analysis of routine neuromonitoring of recurrent laryngeal nerve in total thyroidectomy.
Sanabria, Álvaro; Ramírez, Adonis
2015-01-01
Thyroidectomy is a common surgery. Routine searching of the recurrent laryngeal nerve is the most important strategy to avoid palsy. Neuromonitoring has been recommended to decrease recurrent laryngeal nerve palsy. To assess if neuromonitoring of recurrent laryngeal nerve during thyroidectomy is cost-effective in a developing country. We designed a decision analysis to assess the cost-effectiveness of recurrent laryngeal nerve neuromonitoring. For probabilities, we used data from a meta-analysis. Utility was measured using preference values. We considered direct costs. We conducted a deterministic and a probabilistic analysis. We did not find differences in utility between arms. The frequency of recurrent laryngeal nerve injury was 1% in the neuromonitor group and 1.6% for the standard group. Thyroidectomy without monitoring was the less expensive alternative. The incremental cost-effectiveness ratio was COP$ 9,112,065. Routine neuromonitoring in total thyroidectomy with low risk of recurrent laryngeal nerve injury is neither cost-useful nor cost-effective in the Colombian health system.
Whiley, Harriet
2016-12-24
Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups.
Whiley, Harriet
2016-01-01
Legionella is an opportunistic pathogen of public health significance. One of the main sources of Legionella is potable water systems. As a consequence of aging populations there is an increasing demographic considered at high risk for Legionellosis and, as such, a review of the guidelines is required. Worldwide, Legionella has been detected from many potable water sources, suggesting it is ubiquitous in this environment. Previous studies have identified the limitations of the current standard method for Legionella detection and the high possibility of it returning both false negative and false positive results. There is also huge variability in Legionella test results for the same water sample when conducted at different laboratories. However, many guidelines still recommend the testing of water systems. This commentary argues for the removal of routine Legionella monitoring from all water distribution guidelines. This procedure is financially consuming and false negatives may result in managers being over-confident with a system or a control mechanism. Instead, the presence of the pathogen should be assumed and focus spent on managing appropriate control measures and protecting high-risk population groups. PMID:28029126
System for routine surface anthropometry using reprojection registration
NASA Astrophysics Data System (ADS)
Sadleir, R. J.; Owens, R. A.; Hartmann, P. E.
2003-11-01
Range data measurement can be usefully applied to non-invasive monitoring of anthropometric changes due to disease, healing or during normal physiological processes. We have developed a computer vision system that allows routine capture of biological surface shapes and accurate measurement of anthropometric changes, using a structured light stripe triangulation system. In many applications involving relocation of soft tissue for image-guided surgery or anthropometry it is neither accurate nor practical to apply fiducial markers directly to the body. This system features a novel method of achieving subject re-registration that involves application of fiducials by a standard data projector. Calibration of this reprojector is achieved using a variation of structured lighting techniques. The method allows accurate and comparable repositioning of elastic surfaces. Tests of repositioning using the reprojector found a significant improvement in subject registration compared to an earlier method which used video overlay comparison only. It has a current application to the measurement of breast volume changes in lactating mothers, but may be extended to any application where repeatable positioning and measurement is required.
Noise-based seismic monitoring of the Campi Flegrei caldera
NASA Astrophysics Data System (ADS)
Zaccarelli, Lucia; Bianco, Francesca
2017-03-01
The Campi Flegrei caldera is one of the highest risk volcanic fields worldwide, because of its eruptive history and the large population hosted within the caldera. It experiences bradiseismic crises: sudden uplift with low energetic seismic swarm occurrences. No seismicity is recorded out of these deformation rate changes. Therefore, a continuous seismic monitoring of the caldera is possible only by means of the ambient seismic noise. We apply a noise-based seismic monitoring technique to the cross correlations of 5 year recordings at the mobile seismic network. The resulting relative velocity variations are compared to the temporal behavior of the geophysical and geochemical observations routinely sampled at Campi Flegrei. We discriminate between two kinds of crustal stress field variations acting at different timescales. They are related to a possible magmatic intrusion and to the gradual heating of the hydrothermal system, respectively. This study sets up the basis for future volcano monitoring strategies.
The Savannah River Site`s Groundwater Monitoring Program, first quarter 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Environmental Monitoring Section of the Environmental and Health Protection (EHP) Department administers the Savannah River Site`s Groundwater Monitoring Program. During first quarter 1989 (January--March), EHP conducted routine sampling of monitoring wells and drinking water locations. EHP collected the drinking water samples from Savannah River Site (SRS) drinking water systems supplied by wells. EHP established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, background levels in SRS groundwater, and drinking watermore » standards. An explanation of flagging criteria for the first quarter is presented in the Flagging Criteria section of this document. All analytical results from first quarter 1989 are listed in this report, which is distributed to all waste-site custodians.« less
The Savannah River Site`s Groundwater Monitoring Program, third quarter 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Environmental Monitoring Section of the Environmental and Health Protection (EHP) Department administers the Savannah River Site`s Groundwater Monitoring Program. During third quarter 1989 (July--September), EHP conducted routine sampling of monitoring wells and drinking water locations. EHP collected the drinking water samples from Savannah River Site (SRS) drinking water systems supplied by wells. EHP established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead they aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, backgroundmore » levels in SRS groundwater, and drinking water standards. An explanation of flagging criteria for the third quarter is presented in the Flagging Criteria section of this document. All analytical results from third quarter 1989 are listed in this report, which is distributed to all waste-site custodians.« less
The Savannah River Site's Groundwater Monitoring Program, third quarter 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Environmental Monitoring Section of the Environmental and Health Protection (EHP) Department administers the Savannah River Site's Groundwater Monitoring Program. During third quarter 1989 (July--September), EHP conducted routine sampling of monitoring wells and drinking water locations. EHP collected the drinking water samples from Savannah River Site (SRS) drinking water systems supplied by wells. EHP established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria do not define contamination levels; instead they aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, backgroundmore » levels in SRS groundwater, and drinking water standards. An explanation of flagging criteria for the third quarter is presented in the Flagging Criteria section of this document. All analytical results from third quarter 1989 are listed in this report, which is distributed to all waste-site custodians.« less
The Savannah River Site's Groundwater Monitoring Program, first quarter 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Environmental Monitoring Section of the Environmental and Health Protection (EHP) Department administers the Savannah River Site's Groundwater Monitoring Program. During first quarter 1989 (January--March), EHP conducted routine sampling of monitoring wells and drinking water locations. EHP collected the drinking water samples from Savannah River Site (SRS) drinking water systems supplied by wells. EHP established two sets of flagging criteria in 1986 to assist in the management of sample results. The flagging criteria aid personnel in sample scheduling, interpretation of data, and trend identification. The flagging criteria are based on detection limits, background levels in SRS groundwater, and drinking watermore » standards. An explanation of flagging criteria for the first quarter is presented in the Flagging Criteria section of this document. All analytical results from first quarter 1989 are listed in this report, which is distributed to all waste-site custodians.« less
Fuel cell system shutdown with anode pressure control
Clingerman, Bruce J.; Doan, Tien M.; Keskula, Donald H.
2002-01-01
A venting methodology and pressure sensing and vent valving arrangement for monitoring anode bypass valve operating during the normal shutdown of a fuel cell apparatus of the type used in vehicle propulsion systems. During a normal shutdown routine, the pressure differential between the anode inlet and anode outlet is monitored in real time in a period corresponding to the normal closing speed of the anode bypass valve and the pressure differential at the end of the closing cycle of the anode bypass valve is compared to the pressure differential at the beginning of the closing cycle. If the difference in pressure differential at the beginning and end of the anode bypass closing cycle indicates that the anode bypass valve has not properly closed, a system controller switches from a normal shutdown mode to a rapid shutdown mode in which the anode inlet is instantaneously vented by rapid vents.
Real-time decision support systems: the famine early warning system network
Funk, Christopher C.; Verdin, James P.
2010-01-01
A multi-institutional partnership, the US Agency for International Development’s Famine Early Warning System Network (FEWS NET) provides routine monitoring of climatic, agricultural, market, and socioeconomic conditions in over 20 countries. FEWS NET supports and informs disaster relief decisions that impact millions of people and involve billions of dollars. In this chapter, we focus on some of FEWS NET’s hydrologic monitoring tools, with a specific emphasis on combining “low frequency” and “high frequency” assessment tools. Low frequency assessment tools, tied to water and food balance estimates, enable us to evaluate and map long-term tendencies in food security. High frequency assessments are supported by agrohydrologic models driven by satellite rainfall estimates, such as the Water Requirement Satisfaction Index (WRSI). Focusing on eastern Africa, we suggest that both these high and low frequency approaches are necessary to capture the interaction of slow variations in vulnerability and the relatively rapid onset of climatic shocks.
In-situ material-motion diagnostics and fuel radiography in experimental reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVolpi, A.
1982-01-01
Material-motion monitoring has become a routine part of in-pile transient reactor-safety experiments. Diagnostic systems, such as the fast-neutron hodoscope, were developed for the purpose of providing direct time-resolved data on pre-failure fuel motion, cladding-breach time and location, and post-failure fuel relocation. Hodoscopes for this purpose have been installed at TREAT and CABRI; other types of imaging systems that have been tested are a coded-aperture at ACRR and a pinhole at TREAT. Diagnostic systems that use penetrating radiation emitted from the test section can non-invasively monitor fuel without damage to the measuring instrument during the radiographic images of test sections installedmore » in the reator. Studies have been made of applications of hodoscopes to other experimental reactors, including PBF, FARET, STF, ETR, EBR-II, SAREF-STF, and DMT.« less
40 CFR 141.858 - Repeat monitoring and E. coli requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 24 2013-07-01 2013-07-01 false Repeat monitoring and E. coli....858 Repeat monitoring and E. coli requirements. (a) Repeat monitoring. (1) If a sample taken under... exceeded. (b) Escherichia coli (E. coli) testing. (1) If any routine or repeat sample is total coliform...
Marzegalli, Maurizio; Landolina, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Pappone, Alessia; Guenzati, Giuseppe; Campana, Carlo; Frigerio, Maria; Parati, Gianfranco; Curnis, Antonio; Colangelo, Irene; Valsecchi, Sergio
2009-01-01
Background Heart failure patients with implantable defibrillators (ICD) frequently visit the clinic for routine device monitoring. Moreover, in the case of clinical events, such as ICD shocks or alert notifications for changes in cardiac status or safety issues, they often visit the emergency department or the clinic for an unscheduled visit. These planned and unplanned visits place a great burden on healthcare providers. Internet-based remote device interrogation systems, which give physicians remote access to patients' data, are being proposed in order to reduce routine and interim visits and to detect and notify alert conditions earlier. Methods The EVOLVO study is a prospective, randomized, parallel, unblinded, multicenter clinical trial designed to compare remote ICD management with the current standard of care, in order to assess its ability to treat and triage patients more effectively. Two-hundred patients implanted with wireless-transmission-enabled ICD will be enrolled and randomized to receive either the Medtronic CareLink® monitor for remote transmission or the conventional method of in-person evaluations. The purpose of this manuscript is to describe the design of the trial. The results, which are to be presented separately, will characterize healthcare utilizations as a result of ICD follow-up by means of remote monitoring instead of conventional in-person evaluations. Trial registration ClinicalTrials.gov: NCT00873899 PMID:19538734
Technical basis for internal dosimetry at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.
1991-07-01
The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products ({sup 58}Co, {sup 60}Co, {sup 54}Mn, and {sup 59}Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium,. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation and bioassay follow-up treatment. 78more » refs., 35 figs., 115 tabs.« less
Technical basis for internal dosimetry at Hanford
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sula, M.J.; Carbaugh, E.H.; Bihl, D.E.
1989-04-01
The Hanford Internal Dosimetry Program, administered by Pacific Northwest Laboratory for the US Department of Energy, provides routine bioassay monitoring for employees who are potentially exposed to radionuclides in the workplace. This report presents the technical basis for routine bioassay monitoring and the assessment of internal dose at Hanford. The radionuclides of concern include tritium, corrosion products (/sup 58/Co, /sup 60/Co, /sup 54/Mn, and /sup 59/Fe), strontium, cesium, iodine, europium, uranium, plutonium, and americium. Sections on each of these radionuclides discuss the sources and characteristics; dosimetry; bioassay measurements and monitoring; dose measurement, assessment, and mitigation; and bioassay follow-up treatment. 64more » refs., 42 figs., 118 tabs.« less
NASA Astrophysics Data System (ADS)
Msagati, Titus A. M.; Mamba, Bhekie B.
The supported liquid membrane (SLM) extraction technique has been developed and successfully used for the monitoring of trace quantities of ionisable organic contaminants, including 17β-estradiol and its metabolites, testosterones and their methyl ester derivatives, benzimidazole anthelmintic antibiotics and sulphonamides in aquatic systems. A number of parameters which control the mass transfer in the supported liquid membrane extraction process such as donor and acceptor pH, extraction time and the type of organic liquid membrane were optimised to enhance the efficiency of the liquid membrane in the removal of these compounds. The method developed gave very low detection limits (0.3 ng/l to 2.4 ng/l for 17β-estradiol and its metabolites; between 1 μg/l and 20 μg/l for sulphonamides; and between 0.1 ng/l and 10 ng/l for benzimidazole anthelmintic compounds). The SLM method showed good linearity, reproducibility and repeatability values and is therefore suitable for routine monitoring of such compounds in water and wastewater systems.
Acute confusional state of unknown cause in the elderly: a study with continuous EEG monitoring.
Naeije, Gilles; Gaspard, Nicolas; Depondt, Chantal; Pepersack, Thierry; Legros, Benjamin
2012-03-01
Acute confusional state (ACS) is a frequent cause of emergency consultation in the elderly. Many causes of ACS are also risk factors for seizures. Both non-convulsive seizures and status epilepticus can cause acute confusion. The yield of routine EEG may not be optimal in case of prolonged post-ictal confusion. We thus, sought to evaluate the yield of CEEG in identifying seizures in elderly patients with ACS of unknown origin. We reviewed our CEEG database for patients over 75 years with ACS and collected EEG, CEEG and clinical information. Thirty-one percent (15/48) of the CEEG performed in elderly patients were done for ACS. Routine EEG did not reveal any epileptic anomalies in 7/15 patients. Among those, CEEG identified interictal epileptiform discharges (IED) in 2 and NCSE in 1. In 8/15 patients, routine EEG revealed epileptiform abnormalities: 3 with IED (including 1 with periodic lateralized discharges), 3 with non-convulsive seizures (NCSz) and 2 with non-convulsive status epilepticus (NCSE). Among patients with only IED, CEEG revealed NCSz in 1 and NCSE in 2. This retrospective study suggests that NCSz and NCSE may account for more cases of ACS than what was previously thought. A single negative routine EEG does not exclude this diagnosis. Continuous EEG (CEEG) monitoring is more revealing than routine EEG for the detection of NCSE and NCSz in confused elderly. The presence of IED in the first routine EEG strongly suggests concomitant NCSz or NCSE. Prospective studies are required to further determine the role of CEEG monitoring in the assessment of ACS in the elderly and to establish the incidence of NCSz and NCSE in this setting. Copyright © 2012 Elsevier Inc. All rights reserved.
Ciocchetti, Marco; Massaroni, Carlo; Saccomandi, Paola; Caponero, Michele A.; Polimadei, Andrea; Formica, Domenico; Schena, Emiliano
2015-01-01
Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations. PMID:26389961
A Survey of Visualization Tools Assessed for Anomaly-Based Intrusion Detection Analysis
2014-04-01
objective? • What vulnerabilities exist in the target system? • What damage or other consequences are likely? • What exploit scripts or other attack...languages C, R, and Python; no response capabilities. JUNG https://blogs.reucon.com/asterisk- java /tag/visualization/ Create custom layouts and can...annotate graphs, links, nodes with any Java data type. Must be familiar with coding in Java to call the routines; no monitoring or response
Hammerl, J A; Lasch, P; Nitsche, A; Dabrowski, P W; Hahmann, H; Wicke, A; Kleta, S; Al Dahouk, S; Dieckmann, R
2015-07-23
In 2013, contaminated liquid soap was detected by routine microbiological monitoring of consumer products through state health authorities. Because of its high load of Klebsiella oxytoca, the liquid soap was notified via the European Union Rapid Alert System for Dangerous Non-Food Products (EU-RAPEX) and recalled. Here, we present two draft genome sequences and a summary of their general features. Copyright © 2015 Hammerl et al.
Rigla, Mercedes
2011-01-01
Although current systems for continuous glucose monitoring (CGM) are the result of progressive technological improvement, and although a beneficial effect on glucose control has been demonstrated, few patients are using them. Something similar has happened to telemedicine (TM); in spite of the long-term experience, which began in the early 1980s, no TM system has been widely adopted, and presential visits are still almost the only way diabetologists and patients communicate. The hypothesis developed in this article is that neither CGM nor TM will ever be routinely implemented separately, and their consideration as essential elements for standard diabetes care will one day come from their integration as parts of a telemedical monitoring platform. This platform, which should include artificial intelligence for giving decision support to patients and physicians, will represent the core of a more complex global agent for diabetes care, which will provide control algorithms and risk analysis among other essential functions. © 2010 Diabetes Technology Society.
Morak, Juergen; Schwarz, Mark; Hayn, Dieter; Schreier, Guenter
2012-01-01
Poor patients' adherence to intake of prescribed medication has been identified as a serious problem in the treatment of chronically ill patients. Technical solutions are needed to measure and - if necessary - to increase the patients' adherence. A telemonitoring solution was developed to record a patient's medication intake based on smart blisters and mobile phones with NFC functionality. The components allowed recording of drug type, timestamp, and dosage of pills taken. The system's usability and technical feasibility was evaluated in the course of an application study. Over a period of 13 months 59 patients suffering from diabetes were monitored. 1,760 blisters were handed out to these patients and 14,843 takeout events were recorded and transmitted via mobile phone. Results indicate the feasibility of this concept to monitor adherence. Although the system still needs to be optimized for routine use it shows the potential for targeting the problem of poor patient adherence by NFC enabled devices.
Sun, Li; Wong, Ka Chun; Wei, Peng; Ye, Sheng; Huang, Hao; Yang, Fenhuan; Westerdahl, Dane; Louie, Peter K K; Luk, Connie W Y; Ning, Zhi
2016-02-05
This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO) and nitrogen dioxide (NO2) pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI) for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring.
Sun, Li; Wong, Ka Chun; Wei, Peng; Ye, Sheng; Huang, Hao; Yang, Fenhuan; Westerdahl, Dane; Louie, Peter K.K.; Luk, Connie W.Y.; Ning, Zhi
2016-01-01
This study presents the development and evaluation of a next generation air monitoring system with both laboratory and field tests. A multi-parameter algorithm was used to correct for the impact of environmental conditions on the electrochemical sensors for carbon monoxide (CO) and nitrogen dioxide (NO2) pollutants. The field evaluation in an urban roadside environment in comparison to designated monitors showed good agreement with measurement error within 5% of the pollutant concentrations. Multiple sets of the developed system were then deployed in the Hong Kong Marathon 2015 forming a sensor-based network along the marathon route. Real-time air pollution concentration data were wirelessly transmitted and the Air Quality Health Index (AQHI) for the Green Marathon was calculated, which were broadcast to the public on an hourly basis. The route-specific sensor network showed somewhat different pollutant patterns than routine air monitoring, indicating the immediate impact of traffic control during the marathon on the roadside air quality. The study is one of the first applications of a next generation sensor network in international sport events, and it demonstrated the usefulness of the emerging sensor-based air monitoring technology in rapid network deployment to supplement existing air monitoring. PMID:26861336
Daily life activity routine discovery in hemiparetic rehabilitation patients using topic models.
Seiter, J; Derungs, A; Schuster-Amft, C; Amft, O; Tröster, G
2015-01-01
Monitoring natural behavior and activity routines of hemiparetic rehabilitation patients across the day can provide valuable progress information for therapists and patients and contribute to an optimized rehabilitation process. In particular, continuous patient monitoring could add type, frequency and duration of daily life activity routines and hence complement standard clinical scores that are assessed for particular tasks only. Machine learning methods have been applied to infer activity routines from sensor data. However, supervised methods require activity annotations to build recognition models and thus require extensive patient supervision. Discovery methods, including topic models could provide patient routine information and deal with variability in activity and movement performance across patients. Topic models have been used to discover characteristic activity routine patterns of healthy individuals using activity primitives recognized from supervised sensor data. Yet, the applicability of topic models for hemiparetic rehabilitation patients and techniques to derive activity primitives without supervision needs to be addressed. We investigate, 1) whether a topic model-based activity routine discovery framework can infer activity routines of rehabilitation patients from wearable motion sensor data. 2) We compare the performance of our topic model-based activity routine discovery using rule-based and clustering-based activity vocabulary. We analyze the activity routine discovery in a dataset recorded with 11 hemiparetic rehabilitation patients during up to ten full recording days per individual in an ambulatory daycare rehabilitation center using wearable motion sensors attached to both wrists and the non-affected thigh. We introduce and compare rule-based and clustering-based activity vocabulary to process statistical and frequency acceleration features to activity words. Activity words were used for activity routine pattern discovery using topic models based on Latent Dirichlet Allocation. Discovered activity routine patterns were then mapped to six categorized activity routines. Using the rule-based approach, activity routines could be discovered with an average accuracy of 76% across all patients. The rule-based approach outperformed clustering by 10% and showed less confusions for predicted activity routines. Topic models are suitable to discover daily life activity routines in hemiparetic rehabilitation patients without trained classifiers and activity annotations. Activity routines show characteristic patterns regarding activity primitives including body and extremity postures and movement. A patient-independent rule set can be derived. Including expert knowledge supports successful activity routine discovery over completely data-driven clustering.
Gaw, James R; Crowley, Steven; Monagle, Paul; Jones, Sophie; Newall, Fiona
2013-07-01
The use of point-of-care (POC) devices within the home for routine INR monitoring has demonstrated reliability, safety and effectiveness in the management of infants and children requiring long-term warfarin therapy. However, a comprehensive cost-analysis of using this method of management, compared to attending anticoagulation clinics has not been reported. The aim of this study was to compare the estimated societal costs of attending anticoagulation clinics for routine INR monitoring to using a POC test in the home. This study used a comparative before-and-after design that included 60 infants and children managed via the Haematology department at a tertiary paediatric centre. Each participant was exposed to both modes of management at various times for a period of ≥3 months. A questionnaire, consisting of 25 questions was sent to families to complete and return. Data collected included: the frequency of monitoring, mode of travel to and from clinics, total time consumed, and primary carer's income level. The home monitoring cohort saved a total of 1 hour 19 minutes per INR test compared to attending anticoagulation clinics and had a cost saving to society of $66.83 (AUD) per INR test compared to traditional care; incorporating health sector costs, travel expenses and lost time. The traditional model of care requires a considerable investment of time per test from both child and carer. Home INR monitoring in infants and children provides greater societal economic benefits compared to traditional models. Copyright © 2013 Elsevier Ltd. All rights reserved.
Blood Glucose Monitoring Before and After Type 1 Diabetes Clinic Visits.
Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Wright, Nancy; Deeb, Larry C
2017-12-23
To determine patterns of blood glucose monitoring in children and adolescents with type 1 diabetes (T1D) before and after routine T1D clinic visits. Blood glucose monitoring data were downloaded at four consecutive routine clinic visits from children and adolescents aged 5-18 years. Linear mixed models were used to analyze patterns of blood glucose monitoring in patients who had at least 28 days of data stored in their blood glucose monitors. In general, the frequency of blood glucose monitoring decreased across visits, and younger children engaged in more frequent blood glucose monitoring. Blood glucose monitoring increased before the T1D clinic visits in younger children, but not in adolescents. It declined after the visit regardless of age. Members of the T1D care team need to consider that a T1D clinic visit may prompt an increase in blood glucose monitoring when making treatment changes and recommendations. Tailored interventions are needed to maintain that higher level of adherence across time. © The Author(s) 2017. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
NASA Technical Reports Server (NTRS)
Schumann, H. H.
1981-01-01
Ground surveys and aerial observations were used to monitor rapidly changing moisture conditions in the Salt-Verde watershed. Repetitive satellite snow cover observations greatly reduce the necessity for routine aerial snow reconnaissance flights over the mountains. High resolution, multispectral imagery provided by LANDSAT satellite series enabled rapid and accurate mapping of snow-cover distributions for small- to medium-sized subwatersheds; however, the imagery provided only one observation every 9 days of about a third of the watershed. Low resolution imagery acquired by the ITOSa dn SMS/GOES meteorological satellite series provides the daily synoptic observation necessary to monitor the rapid changes in snow-covered area in the entire watershed. Short term runoff volumes can be predicted from daily sequential snow cover observations.
Harcourt, S E; Morbey, R A; Loveridge, P; Carrilho, L; Baynham, D; Povey, E; Fox, P; Rutter, J; Moores, P; Tiffen, J; Bellerby, S; McIntosh, P; Large, S; McMenamin, J; Reynolds, A; Ibbotson, S; Smith, G E; Elliot, A J
2017-03-01
Public Health England (PHE) coordinates a suite of real-time national syndromic surveillance systems monitoring general practice, emergency department and remote health advice data. We describe the development and informal evaluation of a new syndromic surveillance system using NHS 111 remote health advice data. NHS 111 syndromic indicators were monitored daily at national and local level. Statistical models were applied to daily data to identify significant exceedances; statistical baselines were developed for each syndrome and area using a multi-level hierarchical mixed effects model. Between November 2013 and October 2014, there were on average 19 095 NHS 111 calls each weekday and 43 084 each weekend day in the PHE dataset. There was a predominance of females using the service (57%); highest percentage of calls received was in the age group 1-4 years (14%). This system was used to monitor respiratory and gastrointestinal infections over the winter of 2013-14, the potential public health impact of severe flooding across parts of southern England and poor air quality episodes across England in April 2014. This new system complements and supplements the existing PHE syndromic surveillance systems and is now integrated into the routine daily processes that form this national syndromic surveillance service. © Crown copyright 2016.
Shenson, Douglas; Adams, Mary; Bolen, Julie
2008-06-01
Population-based rates for the delivery of adult vaccinations or screenings are typically tracked as individual services. The current approach is useful in monitoring progress toward national health goals but does not yield information regarding how many U.S. adults receive a combination of preventive services routinely recommended based on a person's age and gender. A composite measure is important for policymaking, for developing public health interventions, and for monitoring the quality of clinical care. During the period under study, influenza vaccination was newly recommended (2000) to be routinely delivered to adults in this age range. The objective of the study was to compare the delivery of routine clinical preventive services to U.S. adults aged 50-64 years between 1997 and 2004 using a composite measure that includes cancer screenings and vaccinations. Data were collected via telephone surveys in 1997, 2002, and 2004 as part of the Behavioral Risk Factor Surveillance System. The participants were randomly selected adults aged 50-64 years in the 50 states and the District of Columbia in the selected years. Sample sizes ranged from 24,917 to 77,244. The composite measure includes screening for colorectal cancer, cervical cancer, breast cancer, and vaccination against influenza (2002 and 2004 only). The composite measure quantifies the percentage of adults who are up-to-date with the complete set according to recommended schedules. With the inclusion of newly recommended influenza vaccination, the percentage of men and women aged 50-64 who were up-to-date on all selected measures in 2004 was 23.4% and 23.0%, respectively, compared with 37.6% and 30.5% in 1997. Without including influenza vaccination, the percentage of up-to-date adults aged 50-64 would have risen in 2004 to 50.5% (men) and to 44.7% (women). For both sexes, results varied by education, race/ethnicity, marriage status, insurance status, health status, and state. In 2004, the percentage of adults aged 50-64 years receiving routinely recommended cancer screenings and influenza vaccination was low with fewer than 1 in 4 being up to date.
English, Lacey; Miller, James S; Mbusa, Rapheal; Matte, Michael; Kenney, Jessica; Bwambale, Shem; Ntaro, Moses; Patel, Palka; Mulogo, Edgar; Stone, Geren S
2016-04-29
In Uganda, over half of under-five child mortality is attributed to three infectious diseases: malaria, pneumonia and diarrhoea. Integrated community case management (iCCM) trains village health workers (VHWs) to provide in-home diagnosis and treatment of these common childhood illnesses. For severely ill children, iCCM relies on a functioning referral system to ensure timely treatment at a health facility. However, referral completion rates vary widely among iCCM programmes and are difficult to monitor. The Bugoye Integrated Community Case Management Initiative (BIMI) is an iCCM programme operating in Bugoye sub-county, Uganda. This case study describes BIMI's experience with monitoring referral completion at Bugoye Health Centre III (BHC), and outlines improvements to be made within iCCM referral systems. This study triangulated multiple data sources to evaluate the strengths and gaps in the BIMI referral system. Three quantitative data sources were reviewed: (1) VHW report of referred patients, (2) referral forms found at BHC, and (3) BHC patient records. These data sources were collated and triangulated from January-December 2014. The goal was to determine if patients were completing their referrals and if referrals were adequately documented using routine data sources. From January-December 2014, there were 268 patients referred to BHC, as documented by VHWs. However, only 52 of these patients had referral forms stored at BHC. Of the 52 referral forms found, 22 of these patients were also found in BHC register books recorded by clinic staff. Thus, the study found a mismatch between VHW reports of patient referrals and the referral visits documented at BHC. This discrepancy may indicate several gaps: (1) referred patients may not be completing their referral, (2) referral forms may be getting lost at BHC, and, (3) referred patients may be going to other health facilities or drug shops, rather than BHC, for their referral. This study demonstrates the challenges of effectively monitoring iCCM referral completion, given identified limitations such as discordant data sources, incomplete record keeping and lack of unique identifiers. There is a need to innovate and improve the ways by which referral compliance is monitored using routine data, in order to improve the percentage of referrals completed. Through research and field experience, this study proposes programmatic and technological solutions to rectify these gaps within iCCM programmes facing similar challenges. With improved monitoring, VHWs will be empowered to increase referral completion, allowing critically ill children to access needed health services.
The principal activity at the NTS is testing of nuclear devices, though other related projects are also conducted. The principal activities of the Off-Site Radiological Safety Program are routine environmental monitoring for radioactive materials in various media and for radiatio...
A principal activity of the Offsite Radiological Safety Program is routine environmental monitoring for radioactive materials in various media and for radiation in areas which may be affected by nuclear tests. It is conducted to document compliance with standards, to identify tre...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thrall, K.D.
The purpose of this project was to demonstrate the ``Exposure-to- Risk`` monitoring system in an actual occupational environment. The system is a unique combination of existing hardware with proprietary software to create an integrated means of assessing occupational exposures to volatile organic compounds. One component of this system utilizes a portable mass spectrometer developed by Teledyne Electronic Technologies. Integration of the system was accomplished under Laboratory Directed Research and Development (LDRD) funding. Commercialization of the system will take place following demonstration in an actual occupational environment, and will include, in part, Teledyne Electronic Technologies. The Exposure-to-Risk monitoring system will benefitmore » DOE by overcoming present-day limitations in worker health protection monitoring. There are numerous sites within the` DOE complex where many different hazardous chemicals are used on a routine basis. These chemicals range from paint stripers and cleaning solvents to chemical warfare agents, each having its own degree of potential adverse health risk to a worker. Thus, a real concern for DOE is to ensure that a worker is properly monitored to assess any adverse health risk from exposure to potentially hazardous chemicals. With current industrial hygiene technologies, this is an arduous task. The Exposure-to-Risk monitoring system integrates a patented breath-inlet device connecting a subject`s exhaled breath directly with a field-portable mass spectrometer with physiologically based pharmacokinetic (PBPK) modeling to estimate the target tissue dose following a chemical exposure. Estimation of the adverse health risk prediction follows from the exposure/dose calculation based on currently accepted methodologies. This new system can determine, in the field, the possible adverse health risks on a daily basis to an individual worker.« less
Systematic monitoring and evaluation of M7 scanner performance and data quality
NASA Technical Reports Server (NTRS)
Stewart, S.; Christenson, D.; Larsen, L.
1974-01-01
An investigation was conducted to provide the information required to maintain data quality of the Michigan M7 Multispectral scanner by systematic checks on specific system performance characteristics. Data processing techniques which use calibration data gathered routinely every mission have been developed to assess current data quality. Significant changes from past data quality are thus identified and attempts made to discover their causes. Procedures for systematic monitoring of scanner data quality are discussed. In the solar reflective region, calculations of Noise Equivalent Change in Radiance on a permission basis are compared to theoretical tape-recorder limits to provide an estimate of overall scanner performance. M7 signal/noise characteristics are examined.
1976-01-01
Trickling Filter Fairchild A.F.B. Trickling Filter Town of Medical Lake Lagoon Town of Fairfield Lagoon Town of Millwood Activated Sludge (Extended Aeration...sewer system is subject to high levels of in- filtration. The treatment plant has ice problems in winter, trickling filter spreading arm clogging...lagoons. There is need of a routine effluent quan- tity/quality monitoring program. Tekoa. The trickling filter plant is poorly maintained to the point
Preparing routine health information systems for immediate health responses to disasters
Aung, Eindra; Whittaker, Maxine
2013-01-01
During disaster times, we need specific information to rapidly plan a disaster response, especially in sudden-onset disasters. Due to the inadequate capacity of Routine Health Information Systems (RHIS), many developing countries face a lack of quality pre-disaster health-related data and efficient post-disaster data processes in the immediate aftermath of a disaster. Considering the significance of local capacity during the early stages of disaster response, RHIS at local, provincial/state and national levels need to be strengthened so that they provide relief personnel up-to-date information to plan, organize and monitor immediate relief activities. RHIS professionals should be aware of specific information needs in disaster response (according to the Sphere Project’s Humanitarian Minimum Standards) and requirements in data processes to fulfil those information needs. Preparing RHIS for disasters can be guided by key RHIS-strengthening frameworks; and disaster preparedness must be incorporated into countries’ RHIS. Mechanisms must be established in non-disaster times and maintained between RHIS and information systems of non-health sectors for exchanging disaster-related information and sharing technologies and cost. PMID:23002249
Rommelmann, Vanessa; Setel, Philip W.; Hemed, Yusuf; Angeles, Gustavo; Mponezya, Hamisi; Whiting, David; Boerma, Ties
2005-01-01
OBJECTIVE: To examine the costs of complementary information generation activities in a resource-constrained setting and compare the costs and outputs of information subsystems that generate the statistics on poverty, health and survival required for monitoring, evaluation and reporting on health programmes in the United Republic of Tanzania. METHODS: Nine systems used by four government agencies or ministries were assessed. Costs were calculated from budgets and expenditure data made available by information system managers. System coverage, quality assurance and information production were reviewed using questionnaires and interviews. Information production was characterized in terms of 38 key sociodemographic indicators required for national programme monitoring. FINDINGS: In 2002-03 approximately US$ 0.53 was spent per Tanzanian citizen on the nine information subsystems that generated information on 37 of the 38 selected indicators. The census and reporting system for routine health service statistics had the largest participating populations and highest total costs. Nationally representative household surveys and demographic surveillance systems (which are not based on nationally representative samples) produced more than half the indicators and used the most rigorous quality assurance. Five systems produced fewer than 13 indicators and had comparatively high costs per participant. CONCLUSION: Policy-makers and programme planners should be aware of the many trade-offs with respect to system costs, coverage, production, representativeness and quality control when making investment choices for monitoring and evaluation. In future, formal cost-effectiveness studies of complementary information systems would help guide investments in the monitoring, evaluation and planning needed to demonstrate the impact of poverty-reduction and health programmes. PMID:16184275
Pharmacovigilance in China: current situation, successes and challenges.
Zhang, Li; Wong, Lisa Y L; He, Ying; Wong, Ian C K
2014-10-01
With the integration of the global pharmaceutical economy and the gradual transformation of the healthcare insurance system in China, the legislative framework for a comprehensive regulatory system monitoring the whole process including drug development, manufacture, distribution and use has been established by the China Food and Drug Administration (CFDA) to ensure the safety and effectiveness of medication use. China has established a relatively comprehensive pharmacovigilance system covering regulation, organisation and technology from 1989 to 2014. As of 2013, one national centre, 34 provincial centres and more than 400 municipal centres for adverse drug reaction (ADR) monitoring were included in the four-level pharmacovigilance network (national, provincial, municipal and county) with more than 200,000 grassroot organisation users. The China Adverse Drug Reaction Monitoring System (CADRMS) is an online spontaneous reporting system which connects the four-level pharmacovigilance network. By 2013, CADRMS had received over 6.6 million ADR case reports. After integrating and analysing pharmacovigilance data, the National Centre for ADR Monitoring (NCADRM) publishes medication safety information by releasing ADR bulletins, National ADR Annual Reports and International Pharmacovigilance Newsletters. The NCADRM also routinely provides CADRMS data feedback to manufacturers. The CFDA implemented risk management through several approaches, including arranging 'manufacturer communication meetings', modification of medication package inserts, and restriction, suspension or withdrawal of marketing authorisations. Seamless information exchange with overseas regulatory authorities and organisations remains an area for improvement. Further development of the China pharmacovigilance system in terms of signal generation, post-marketing pharmacoepidemiology research and education is also needed.
OFMTutor: An operator function model intelligent tutoring system
NASA Technical Reports Server (NTRS)
Jones, Patricia M.
1989-01-01
The design, implementation, and evaluation of an Operator Function Model intelligent tutoring system (OFMTutor) is presented. OFMTutor is intended to provide intelligent tutoring in the context of complex dynamic systems for which an operator function model (OFM) can be constructed. The human operator's role in such complex, dynamic, and highly automated systems is that of a supervisory controller whose primary responsibilities are routine monitoring and fine-tuning of system parameters and occasional compensation for system abnormalities. The automated systems must support the human operator. One potentially useful form of support is the use of intelligent tutoring systems to teach the operator about the system and how to function within that system. Previous research on intelligent tutoring systems (ITS) is considered. The proposed design for OFMTutor is presented, and an experimental evaluation is described.
Kinner, Stuart A; Degenhardt, Louisa
2006-09-01
Regular and systematic monitoring of drug markets provides the basis for evidence-based policy. In Australia, trends in ecstasy and related drug (ERD) markets have been monitored in selected jurisdictions since 2000 and nationally since 2003, by the Party Drugs Initiative (PDI). The PDI maximises the validity of conclusions by triangulating information from (a) interviews with regular ecstasy users (REU), (b) interviews with key experts and (c) indicator data. There is currently no other system in Australia for monitoring these markets systematically; however, the value of the PDI has been constrained by the quality of available data. Difficulties in recruiting and interviewing appropriate consumers (REU) and key experts have been experienced, but largely overcome. Limitations of available indicator data from both health and law enforcement continue to present challenges and there remains considerable scope for enhancing existing routine data collection systems, to facilitate monitoring of ERD markets. With an expanding market for ecstasy and related drugs in Australia, and in the context of indicator data that continue to be limited in scope and detail, there is a strong argument for the continued collection of annual, comparable data from a sentinel group of REU, such as those recruited for the PDI.
Equipment for linking the AutoAnalyzer on-line to a computer
Simpson, D.; Sims, G. E.; Harrison, M. I.; Whitby, L. G.
1971-01-01
An Elliott 903 computer with 8K central core store and magnetic tape backing store has been operated for approximately 20 months in a clinical chemistry laboratory. Details of the equipment designed for linking AutoAnalyzers on-line to the computer are described, and data presented concerning the time required by the computer for different processes. The reliability of the various components in daily operation is discussed. Limitations in the system's capabilities have been defined, and ways of overcoming these are delineated. At present, routine operations include the preparation of worksheets for a limited range of tests (five channels), monitoring of up to 11 AutoAnalyzer channels at a time on a seven-day week basis (with process control and automatic calculation of results), and the provision of quality control data. Cumulative reports can be printed out on those analyses for which computer-prepared worksheets are provided but the system will require extension before these can be issued sufficiently rapidly for routine use. PMID:5551384
Power system distributed oscilation detection based on Synchrophasor data
NASA Astrophysics Data System (ADS)
Ning, Jiawei
Along with increasing demand for electricity, integration of renewable energy and deregulation of power market, power industry is facing unprecedented challenges nowadays. Within the last couple of decades, several serious blackouts have been taking place in United States. As an effective approach to prevent that, power system small signal stability monitoring has been drawing more interests and attentions from researchers. With wide-spread implementation of Synchrophasors around the world in the last decade, power systems real-time online monitoring becomes much more feasible. Comparing with planning study analysis, real-time online monitoring would benefit control room operators immediately and directly. Among all online monitoring methods, Oscillation Modal Analysis (OMA), a modal identification method based on routine measurement data where the input is unmeasured ambient excitation, is a great tool to evaluate and monitor power system small signal stability. Indeed, high sampling Synchrophasor data around power system is fitted perfectly as inputs to OMA. Existing methods in OMA for power systems are all based on centralized algorithms applying at control centers only; however, with rapid growing number of online Synchrophasors the computation burden at control centers is and will be continually exponentially expanded. The increasing computation time at control center compromises the real-time feature of online monitoring. The communication efforts between substation and control center will also be out of reach. Meanwhile, it is difficult or even impossible for centralized algorithms to detect some poorly damped local modes. In order to avert previous shortcomings of centralized OMA methods and embrace the new changes in the power systems, two new distributed oscillation detection methods with two new decentralized structures are presented in this dissertation. Since the new schemes brought substations into the big oscillation detection picture, the proposed methods could achieve faster and more reliable results. Subsequently, this claim is tested and approved by test results of IEEE Two-area simulation test system and real power system historian synchrophasor data case studies.
Development and implementation of sepsis alert systems
Harrison, Andrew M.; Gajic, Ognjen; Pickering, Brian W.; Herasevich, Vitaly
2016-01-01
Synopsis/Summary Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Important barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload & alert fatigue, due to suboptimal alert performance. Outside the ICU, additional barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Currently available evidence does not support routine use of sepsis alert systems in clinical practice. However, continuous improvement in both the afferent (data availability and accuracy of detection algorithms) and efferent (evidence-based decision support and smoother integration into clinical workflow) limbs of sepsis alert systems will help translate theoretical advantages into measurable patient benefit. PMID:27229639
Clinical evaluation of a noninvasive alarm system for nocturnal hypoglycemia.
Skladnev, Victor N; Ghevondian, Nejhdeh; Tarnavskii, Stanislav; Paramalingam, Nirubasini; Jones, Timothy W
2010-01-01
The aim of this study was to evaluate the performance of a prototype noninvasive alarm system (HypoMon) for the detection of nocturnal hypoglycemia. A prospective cohort study evaluated an alarm system that included a sensor belt, a radio frequency transmitter for chest belt signals, and a receiver. The receiver incorporated integrated "real-time" algorithms designed to recognize hypoglycemia "signatures" in the physiological parameters monitored by the sensor belt. Fifty-two children and young adults with type 1 diabetes mellitus (T1DM) participated in this blinded, prospective, in-clinic, overnight study. Participants had a mean age of 16 years (standard deviation 2.1, range 12-20 years) and were asked to follow their normal meal and insulin routines for the day of the study. Participants had physiological parameters monitored overnight by a single HypoMon system. Their BG levels were also monitored overnight at regular intervals via an intravenous cannula and read on two independent Yellow Springs Instruments analyzers. Hypoglycemia was not induced by any manipulations of diabetes management, rather the subjects were monitored overnight for "natural" occurrences of hypoglycemia. Performance analyses included comparing HypoMon system alarm times with allowed time windows associated with each hypoglycemic event. The primary recognition algorithm in the prototype alarm system performed at a level consistent with expectations based on prior user surveys. The HypoMon system correctly recognized 8 out of the 11 naturally occurring overnight hypoglycemic events and falsely alarmed on 13 out of the remaining 41 normal nights [sensitivity 73% (8/11), specificity 68% (28/41), positive predictive value 38%,negative predictive value 90%]. The prototype HypoMon shows potential as an adjunct method for noninvasive overnight monitoring for hypoglycemia events in young people with T1DM. 2010 Diabetes Technology Society.
RadNet Sampling and Analyses Schedules
RadNet air monitors operate continuously and samples of air, precipitation and drinking water and analyzed on a routine schedule. RadNet can send deployable monitors to any U.S. location in the case of a radiological emergency.
ANALOG I/O MODULE TEST SYSTEM BASED ON EPICS CA PROTOCOL AND ACTIVEX CA INTERFACE
DOE Office of Scientific and Technical Information (OSTI.GOV)
YENG,YHOFF,L.
2003-10-13
Analog input (ADC) and output (DAC) modules play a substantial role in device level control of accelerator and large experiment physics control system. In order to get the best performance some features of analog modules including linearity, accuracy, crosstalk, thermal drift and so on have to be evaluated during the preliminary design phase. Gain and offset error calibration and thermal drift compensation (if needed) may have to be done in the implementation phase as well. A natural technique for performing these tasks is to interface the analog VO modules and GPIB interface programmable test instruments with a computer, which canmore » complete measurements or calibration automatically. A difficulty is that drivers of analog modules and test instruments usually work on totally different platforms (vxworks VS Windows). Developing new test routines and drivers for testing instruments under VxWorks (or any other RTOS) platform is not a good solution because such systems have relatively poor user interface and developing such software requires substantial effort. EPICS CA protocol and ActiveX CA interface provide another choice, a PC and LabVIEW based test system. Analog 110 module can be interfaced from LabVIEW test routines via ActiveX CA interface. Test instruments can be controlled via LabVIEW drivers, most of which are provided by instrument vendors or by National Instruments. Labview also provides extensive data analysis and process functions. Using these functions, users can generate powerful test routines very easily. Several applications built for Spallation Neutron Source (SNS) Beam Loss Monitor (BLM) system are described in this paper.« less
A Server-Based Mobile Coaching System
Baca, Arnold; Kornfeind, Philipp; Preuschl, Emanuel; Bichler, Sebastian; Tampier, Martin; Novatchkov, Hristo
2010-01-01
A prototype system for monitoring, transmitting and processing performance data in sports for the purpose of providing feedback has been developed. During training, athletes are equipped with a mobile device and wireless sensors using the ANT protocol in order to acquire biomechanical, physiological and other sports specific parameters. The measured data is buffered locally and forwarded via the Internet to a server. The server provides experts (coaches, biomechanists, sports medicine specialists etc.) with remote data access, analysis and (partly automated) feedback routines. In this way, experts are able to analyze the athlete’s performance and return individual feedback messages from remote locations. PMID:22163490
[Clinical experiences with a new reusable pressure transducer].
Brandt, L; Dick, W
1987-08-01
Invasive blood pressure monitoring is increasing in anesthesia and intensive care. Compared to noninvasive methods, it has some decisive advantages: (1) blood pressure trends can be assessed beat by beat, which is important especially in situations of cardiac arrhythmia; (2) respiratory changes in blood pressure as one sign of hypovolemia can be detected easily; and (3) pressure changes induced by the autonomic nervous system become apparent. We studied a new, reusable pressure transducer system, the Medex Novatrans-MX800 in routine intra- and postoperative monitoring of patients undergoing cardiac surgery using the following criteria: (1) handling; (2) accuracy of measurement; (3) durability; and (4) costs. The system is easy to use and has a low susceptability to breakdown. In 29 of 31 transducers tested, the error of measurement over a range of 0-150 mmHg was less than 2% as reported by the manufacturer. Two transducers showed errors of measurement over 5% after 60 times of reuse. The mean reusability rate until the transducer became defective was 75.8 +/- 17.3 in the operating room (19 transducers tested) and 59.7 +/- 29 in the intensive care unit (12 transducers tested, 11 still in use). A comparison of costs shows that the Novatrans-MX800 system is the cheapest system for invasive pressure monitoring available at this time.
A Decade of Monitoring HIV Epidemics in Nigeria: Positioning for Post-2015 Agenda.
Akinwande, Oluyemisi; Bashorun, Adebobola; Azeez, Aderemi; Agbo, Francis; Dakum, Patrick; Abimiku, Alashle; Bilali, Camara; Idoko, John; Ogungbemi, Kayode
2017-07-01
Nigeria accounts for 9% of the global HIV burden and is a signatory to Millennium Development Goals as well as the post-2015 Sustainable Development Goals. This paper reviews maturation of her HIV M&E system and preparedness for monitoring of the post-2015 agenda. Using the UNAIDS criteria for assessing a functional M&E system, a mixed-methods approach of desk review and expert consultations, was employed. Following adoption of a multi-sectoral M&E system, Nigeria experienced improved HIV coordination at the National and State levels, capacity building for epidemic appraisals, spectrum estimation and routine data quality assessments. National data and systems audit processes were instituted which informed harmonization of tools and indicators. The M&E achievements of the HIV response enhanced performance of the National Health Management Information System (NHMIS) using DHIS2 platform following its re-introduction by the Federal Ministry of Health, and also enabled decentralization of data management to the periphery. A decade of implementing National HIV M&E framework in Nigeria and the recent adoption of the DHIS2 provides a strong base for monitoring the Post 2015 agenda. There is however a need to strengthen inter-sectoral data linkages and reduce the rising burden of data collection at the global level.
Klein, Nicola P; Reisinger, Keith S; Johnston, William; Odrljin, Tatjana; Gill, Christopher J; Bedell, Lisa; Dull, Peter
2012-01-01
In phase II studies, MenACWY-CRM elicited robust immunologic responses in young infants. We now present results from our pivotal phase III infant immunogenicity/safety study. In this open-label phase III study, we randomized full-term 2-month-old infants to 4 doses of MenACWY-CRM coadministered with routine vaccines at 2, 4, 6, and 12 months of age or with routine vaccines alone. We monitored for local and systemic reactions and serious adverse events among all study participants and evaluated for sufficiency of the immune responses to MenACWY-CRM through serum bactericidal activity assay with human complement. Bactericidal antibodies were present in 94% to 100% of subjects against each of the serogroups in MenACWY-CRM after the 4-dose series and were 67% to 97% after the first 3 doses. Geometric mean titers were higher after the fourth dose of MenACWY-CRM compared with a single dose of MenACWY-CRM at 12 months of age for all serogroups (range of ratios, 4.5-38). Responses to 3 doses of routine vaccines coadministered with MenACWY-CRM were noninferior to routine vaccinations alone, except for small differences in pneumococcal serotype 6B responses after dose 3 but not dose 4 and pertactin after dose 3. Inclusion of MenACWY-CRM did not affect the safety or reactogenicity profiles of the routine infant vaccine series. A 4-dose series of MenACWY-CRM was highly immunogenic and well tolerated in young infants, and it can be coadministered with routine infant vaccines. Substantial immunity was conferred after the first 3 doses administered at 2, 4, and 6 months of age.
Novel Method for Detection of Air Pollution using Cellular Communication Networks
NASA Astrophysics Data System (ADS)
David, N.; Gao, O. H.
2016-12-01
Air pollution can lead to a wide spectrum of severe and chronic health impacts. Conventional tools for monitoring the phenomenon do not provide a sufficient monitoring solution in a global scale since they are, for example, not representative of the larger space or due to limited deployment as a result of practical limitations, such as: acquisition, installation, and ongoing maintenance costs. Near ground temperature inversions are directly identified with air pollution events since they suppress vertical atmospheric movement and trap pollutants near the ground. Wireless telecommunication links that comprise the data transfer infrastructure in cellular communication networks operate at frequencies of tens of GHz and are affected by different atmospheric phenomena. These systems are deployed near ground level across the globe, including in developing countries such as India, countries in Africa, etc. Many cellular providers routinely store data regarding the received signal levels in the network for quality assurance needs. Temperature inversions cause atmospheric layering, and change the refractive index of the air when compared to standard conditions. As a result, the ducts that are formed can operate, in essence, as atmospheric wave guides, and cause interference (signal amplification / attenuation) in the microwaves measured by the wireless network. Thus, this network is in effect, an existing system of environmental sensors for monitoring temperature inversions and the episodes of air pollution identified with them. This work presents the novel idea, and demonstrates it, in operation, over several events of air pollution which were detected by a standard cellular communication network during routine operation. Reference: David, N. and Gao, H.O. Using cellular communication networks to detect air pollution, Environmental Science & Technology, 2016 (accepted).
Bedini, José Luis; Wallace, Jane F.; Petruschke, Thorsten; Pardo, Scott
2015-01-01
Background: Self-monitoring of blood glucose is crucial for the effective self-management of diabetes. The present study evaluated the accuracy of the Contour® XT blood glucose monitoring system (BGMS) compared to the reference method in a large multicenter study under routine lab conditions at each hospital site. Methods: This study was conducted at 21 leading hospitals in Spain using leftover whole blood samples (n = 2100). Samples were tested with the BGMS using 1 commercial strip lot and the local laboratory hexokinase method. BGMS accuracy was assessed and results were compared to ISO 15197:2013 accuracy limit criteria and by using mean absolute relative difference analysis (MARD), consensus (Parkes) error grid (CEG), and surveillance error grid analyses (SEG). Results: Pooled analysis of 2100 measurements from all sites showed that 99.43% of the BGMS results were within the ranges accepted by the accuracy limit criteria. The overall MARD was 3.85%. MARD was 4.47% for glucose concentrations < 70 mg/dL and 3.81% for concentrations of 70-300 mg/dL. In CEG, most results (99.8%) were within zone A (“no effect on clinical action”); the remaining ones (0.2%) were in zone B (“little to no effect on clinical action”). The SEG analysis showed that most of the results (98.4%) were in the “no risk” zone, with the remaining results in the “slight, lower” risk zone. Conclusions: This is the largest multicenter study of Contour XT BGMS to date, and shows that this BGMS meets the ISO 15197:2013 accuracy limit criteria under local routine conditions in 21 leading Spanish hospitals. PMID:26253142
Bedini, José Luis; Wallace, Jane F; Petruschke, Thorsten; Pardo, Scott
2015-08-07
Self-monitoring of blood glucose is crucial for the effective self-management of diabetes. The present study evaluated the accuracy of the Contour® XT blood glucose monitoring system (BGMS) compared to the reference method in a large multicenter study under routine lab conditions at each hospital site. This study was conducted at 21 leading hospitals in Spain using leftover whole blood samples (n = 2100). Samples were tested with the BGMS using 1 commercial strip lot and the local laboratory hexokinase method. BGMS accuracy was assessed and results were compared to ISO 15197:2013 accuracy limit criteria and by using mean absolute relative difference analysis (MARD), consensus (Parkes) error grid (CEG), and surveillance error grid analyses (SEG). Pooled analysis of 2100 measurements from all sites showed that 99.43% of the BGMS results were within the ranges accepted by the accuracy limit criteria. The overall MARD was 3.85%. MARD was 4.47% for glucose concentrations < 70 mg/dL and 3.81% for concentrations of 70-300 mg/dL. In CEG, most results (99.8%) were within zone A ("no effect on clinical action"); the remaining ones (0.2%) were in zone B ("little to no effect on clinical action"). The SEG analysis showed that most of the results (98.4%) were in the "no risk" zone, with the remaining results in the "slight, lower" risk zone. This is the largest multicenter study of Contour XT BGMS to date, and shows that this BGMS meets the ISO 15197:2013 accuracy limit criteria under local routine conditions in 21 leading Spanish hospitals. © 2015 Diabetes Technology Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fields, M.K.; Davis, R.P.
1992-08-01
A wastewater characterization survey was conducted by members of the Armstrong Laboratory Occupational and Environmental Health directorate Water Quality Function from 28 Oct 91 - 7 Nov 91 at Whiteman AFB, MO. The purpose of the survey was to identify and characterize the wastewater, determine the appropriateness of present disposal methods, determine the need for routine sampling or monitoring and recommend parameters for wastewater analysis. Results of the sampling showed metals and volatile organic discharge in varying concentrations throughout the base. Recommendations are: (1) evaluation of industrial operations and chemical disposal procedures at designated sites; (2) routine monitoring of themore » discharge from the Hospital and Audiovisual for silver; (3) excavation and sediment disposal at the Transportation Washrack and WWTP Effluent discharge point; (4) collection and analyses of sludge at oil water separators, to include the oil and water side; (5) evaluation of the sanitary sewer system for corrosion and sediment buildup by a mobile Reveal and Seal Unit; (6) background soil sample collection and analyses; and (7) pretreatment of Aqueous Film Forming Foam discharge and notification of the Base Bioenvironmental Engineer, Environmental Coordinator, and WWTP personnel when discharge occurs.« less
Time Analyzer for Time Synchronization and Monitor of the Deep Space Network
NASA Technical Reports Server (NTRS)
Cole, Steven; Gonzalez, Jorge, Jr.; Calhoun, Malcolm; Tjoelker, Robert
2003-01-01
A software package has been developed to measure, monitor, and archive the performance of timing signals distributed in the NASA Deep Space Network. Timing signals are generated from a central master clock and distributed to over 100 users at distances up to 30 kilometers. The time offset due to internal distribution delays and time jitter with respect to the central master clock are critical for successful spacecraft navigation, radio science, and very long baseline interferometry (VLBI) applications. The instrument controller and operator interface software is written in LabView and runs on the Linux operating system. The software controls a commercial multiplexer to switch 120 separate timing signals to measure offset and jitter with a time-interval counter referenced to the master clock. The offset of each channel is displayed in histogram form, and "out of specification" alarms are sent to a central complex monitor and control system. At any time, the measurement cycle of 120 signals can be interrupted for diagnostic tests on an individual channel. The instrument also routinely monitors and archives the long-term stability of all frequency standards or any other 1-pps source compared against the master clock. All data is stored and made available for
Time lapse imaging: is it time to incorporate this technology into routine clinical practice?
Bhide, Priya; Maheshwari, Abha; Cutting, Rachel; Seenan, Susan; Patel, Anita; Khan, Khalid; Homburg, Roy
2017-06-01
Time-lapse imaging (TLI) systems for embryo incubation, assessment and selection are a novel technology available to in vitro fertilization (IVF) clinics. However, there is uncertainty about their clinical and cost-effectiveness and insufficient good quality evidence to warrant their routine use. Despite this, enthusiastic commercial marketing and slipping clinical equipoise have led to the widespread hasty introduction of this technology into practice, often at a considerable expense to the patient. We have reviewed the published literature and aim to summarize the strengths, weaknesses, opportunities and threats of these systems. These specialized incubators provide undisturbed embryo culture conditions and, by almost continuous monitoring of embryo development, generate morphokinetic parameters to aid embryo selection. They are thus hypothesized to improve outcomes following IVF. Although literature reports improved reproductive outcomes, these outcomes are largely surrogate and there is a paucity of studies reporting live births. The use of time lapse systems may reduce early pregnancy loss, increase elective single embryo transfers and limit multiple pregnancies through better embryo selection. However, the quality of the studies and hence the evidence so far, is low to moderate quality. We recommend further research producing robust high-quality evidence for and against the use of these systems.
Monitoring and investigating natural disease by veterinary pathologists in diagnostic laboratories.
O'Toole, D
2010-01-01
Many emerging diseases in animals are initially recognized by diagnostic pathologists in animal health laboratories using routine laboratory submissions, in conjunction with clinical veterinarians and wildlife biologists. Familiar recent examples are chronic wasting disease, bovine spongiform encephalopathy, West Nile encephalomyelitis in North America, and postweaning multisystemic wasting syndrome in pigs. The recognition of new diseases in animals requires that the curiosity of diagnosticians be articulated with the capacity of animal health laboratories to create effective diagnostic teams, solicit additional cases from the field at minimal cost to clients, and develop relationships with basic researchers. Bovine neosporosis is used as an example to illustrate how a disease investigation triggered by routine clinical accessions can have international ramifications. Between the late 1980s and 1995, diagnosticians with California's animal health laboratory system identified neosporosis as a cause of reproductive wastage in cattle, characterized the lesions, isolated the agent, defined routes of transmission, met Koch's postulates, and developed diagnostic assays. Diagnostic pathologists catalyzed the process. The neosporosis investigation in California suggests useful attributes of veterinary diagnostic laboratories that pursue emerging diseases identified through routine laboratory accessions.
Infrasound from the 2009 and 2017 DPRK rocket launches
NASA Astrophysics Data System (ADS)
Evers, L. G.; Assink, J. D.; Smets, P. SM
2018-06-01
Supersonic rockets generate low-frequency acoustic waves, that is, infrasound, during the launch and re-entry. Infrasound is routinely observed at infrasound arrays from the International Monitoring System, in place for the verification of the Comprehensive Nuclear-Test-Ban Treaty. Association and source identification are key elements of the verification system. The moving nature of a rocket is a defining criterion in order to distinguish it from an isolated explosion. Here, it is shown how infrasound recordings can be associated, which leads to identification of the rocket. Propagation modelling is included to further constrain the source identification. Four rocket launches by the Democratic People's Republic of Korea in 2009 and 2017 are analysed in which multiple arrays detected the infrasound. Source identification in this region is important for verification purposes. It is concluded that with a passive monitoring technique such as infrasound, characteristics can be remotely obtained on sources of interest, that is, infrasonic intelligence, over 4500+ km.
Application of remote sensing to monitoring and studying dispersion in ocean dumping
NASA Technical Reports Server (NTRS)
Johnson, R. W.; Ohlhorst, C. W.
1981-01-01
Remotely sensed wide area synoptic data provides information on ocean dumping that is not readily available by other means. A qualitative approach has been used to map features, such as river plumes. Results of quantitative analyses have been used to develop maps showing quantitative distributions of one or more water quality parameters, such as suspended solids or chlorophyll a. Joint NASA/NOAA experiments have been conducted at designated dump areas in the U.S. coastal zones to determine the applicability of aircraft remote sensing systems to map plumes resulting from ocean dumping of sewage sludge and industrial wastes. A second objective is related to the evaluation of previously developed quantitative analysis techniques for studying dispersion of materials in these plumes. It was found that plumes resulting from dumping of four waste materials have distinctive spectral characteristics. The development of a technology for use in a routine monitoring system, based on remote sensing techniques, is discussed.
Amorim-Costa, C; Ayres-de-Campos, D; Costa-Santos, C; Bernardes, J
2014-01-01
Digital storage of cardiotocographic (CTG) tracings by fetal central monitoring systems (fCMS) obviates the need for printing, or alternatively, the tracings can be printed in regular paper instead of CTG thermal paper. We aimed at evaluating the impact of the introduction of the Omniview-SisPorto(®) system on CTG paper costs in a large university hospital. After introduction of the fCMS, there was an 87% reduction in median annual expenses with CTG paper in the labour ward (p = 0.011) and a 78% decrease in the prenatal clinic (p = 0.017), despite a more than 40% increase in the median number of observed women. Routine use of fCMS may provide an important reduction in hospital expenses associated with the use of thermal CTG paper, thus reducing the investment made in their acquisition and maintenance.
NASA Astrophysics Data System (ADS)
Simarski, Lynn Teo
Research reported at an AGU session on Galileo's Earth/Moon flyby refined the spacecraft's distinctive portrait of the Earth-Moon system. The Galileo team presented dramatic new views of the Earth and Moon taken last December. Andrew P. Ingersoll showed a color movie of the rotating Earth, made through spectral filters with which Galileo viewed the Earth almost continuously for 25 hours.Galileo also made finely tuned observations of vegetation and clouds, using three very closely spaced spectral wavelengths in the near-infrared, explained W. Reid Thompson. In the resulting images, Argentinian grassland and Brazilian rain forest are clearly distinguished, demonstrating the applicability of this technique for routine monitoring of deforestation, shifts in vegetation due to climate, and other phenomena. Thompson suggested that this capability could be used on the Earth Observing System. One of the spectral bands may also have potential for monitoring cloud condensation, as it appears to differentiate actively condensing, vapor-heavy clouds from higher and drier clouds.
Monitoring radiation use in cardiac fluoroscopy imaging procedures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stevens, Nathaniel T.; Steiner, Stefan H.; Smith, Ian R.
2011-01-15
Purpose: Timely identification of systematic changes in radiation delivery of an imaging system can lead to a reduction in risk for the patients involved. However, existing quality assurance programs involving the routine testing of equipment performance using phantoms are limited in their ability to effectively carry out this task. To address this issue, the authors propose the implementation of an ongoing monitoring process that utilizes procedural data to identify unexpected large or small radiation exposures for individual patients, as well as to detect persistent changes in the radiation output of imaging platforms. Methods: Data used in this study were obtainedmore » from records routinely collected during procedures performed in the cardiac catheterization imaging facility at St. Andrew's War Memorial Hospital, Brisbane, Australia, over the period January 2008-March 2010. A two stage monitoring process employing individual and exponentially weighted moving average (EWMA) control charts was developed and used to identify unexpectedly high or low radiation exposure levels for individual patients, as well as detect persistent changes in the radiation output delivered by the imaging systems. To increase sensitivity of the charts, we account for variation in dose area product (DAP) values due to other measured factors (patient weight, fluoroscopy time, and digital acquisition frame count) using multiple linear regression. Control charts are then constructed using the residual values from this linear regression. The proposed monitoring process was evaluated using simulation to model the performance of the process under known conditions. Results: Retrospective application of this technique to actual clinical data identified a number of cases in which the DAP result could be considered unexpected. Most of these, upon review, were attributed to data entry errors. The charts monitoring the overall system radiation output trends demonstrated changes in equipment performance associated with relocation of the equipment to a new department. When tested under simulated conditions, the EWMA chart was capable of detecting a sustained 15% increase in average radiation output within 60 cases (<1 month of operation), while a 33% increase would be signaled within 20 cases. Conclusions: This technique offers a valuable enhancement to existing quality assurance programs in radiology that rely upon the testing of equipment radiation output at discrete time frames to ensure performance security.« less
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin
2009-01-01
Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.
NASA space station automation: AI-based technology review
NASA Technical Reports Server (NTRS)
Firschein, O.; Georgeff, M. P.; Park, W.; Neumann, P.; Kautz, W. H.; Levitt, K. N.; Rom, R. J.; Poggio, A. A.
1985-01-01
Research and Development projects in automation for the Space Station are discussed. Artificial Intelligence (AI) based automation technologies are planned to enhance crew safety through reduced need for EVA, increase crew productivity through the reduction of routine operations, increase space station autonomy, and augment space station capability through the use of teleoperation and robotics. AI technology will also be developed for the servicing of satellites at the Space Station, system monitoring and diagnosis, space manufacturing, and the assembly of large space structures.
NASA Astrophysics Data System (ADS)
Taira, Ricky K.; Chan, Kelby K.; Stewart, Brent K.; Weinberg, Wolfram S.
1991-07-01
Reliability is an increasing concern when moving PACS from the experimental laboratory to the clinical environment. Any system downtime may seriously affect patient care. The authors report on the several classes of errors encountered during the pre-clinical release of the PACS during the past several months and present the solutions implemented to handle them. The reliability issues discussed include: (1) environmental precautions, (2) database backups, (3) monitor routines of critical resources and processes, (4) hardware redundancy (networks, archives), and (5) development of a PACS quality control program.
Sustainable management for the eastern Mediterranean coast of Turkey.
Berberoglu, Süha
2003-03-01
The objective of this article is to propose a program for the integrated coastal zone management that is required to stimulate and guide sustainable development of the Mediterranean coastal zone of Turkey. Improved data collection, quality control, analysis, and data management will provide a firm basis for future scientific understanding of the East Mediterranean coast of Turkey and will support long-term management. Various innovative procedures were proposed for a promising ecosystem-based approach to manage coastal wetlands in the Mediterranean: remote data acquisition with new technologies; environmental quality monitoring program that will provide a baseline for monitoring; linking a Geographic Information System (GIS) with natural resource management decision routines in the context of operational wetlands, fisheries, tourism management system; environmental sensitivity analysis to ensure that permitted developments are environmentally sustainable; and use of natural species to restore the wetlands and coastal dunes and sustain the system processes. The proposed management scheme will benefit the scientific community in the Mediterranean and the management/planning community in Eastern Turkey.
Sadiq, Rehan; Rodriguez, Manuel J
2005-04-01
Interpreting water quality data routinely generated for control and monitoring purposes in water distribution systems is a complicated task for utility managers. In fact, data for diverse water quality indicators (physico-chemical and microbiological) are generated at different times and at different locations in the distribution system. To simplify and improve the understanding and the interpretation of water quality, methodologies for aggregation and fusion of data must be developed. In this paper, the Dempster-Shafer theory also called theory of evidence is introduced as a potential methodology for interpreting water quality data. The conceptual basis of this methodology and the process for its implementation are presented by two applications. The first application deals with the interpretation of spatial water quality data fusion, while the second application deals with the development of water quality index based on key monitored indicators. Based on the obtained results, the authors discuss the potential contribution of theory of evidence as a decision-making tool for water quality management.
Harvey, Catherine; Brewster, Jill; Bakerly, Nawar Diar; Elkhenini, Hanaa F.; Stanciu, Roxana; Williams, Claire; Brereton, Jacqui; New, John P.; McCrae, John; McCorkindale, Sheila; Leather, David
2016-01-01
Abstract Background The Salford Lung Study (SLS) programme, encompassing two phase III pragmatic randomised controlled trials, was designed to generate evidence on the effectiveness of a once‐daily treatment for asthma and chronic obstructive pulmonary disease in routine primary care using electronic health records. Objective The objective of this study was to describe and discuss the safety monitoring methodology and the challenges associated with ensuring patient safety in the SLS. Refinements to safety monitoring processes and infrastructure are also discussed. The study results are outside the remit of this paper. The results of the COPD study were published recently and a more in‐depth exploration of the safety results will be the subject of future publications. Achievements The SLS used a linked database system to capture relevant data from primary care practices in Salford and South Manchester, two university hospitals and other national databases. Patient data were collated and analysed to create daily summaries that were used to alert a specialist safety team to potential safety events. Clinical research teams at participating general practitioner sites and pharmacies also captured safety events during routine consultations. Confidence in the safety monitoring processes over time allowed the methodology to be refined and streamlined without compromising patient safety or the timely collection of data. The information technology infrastructure also allowed additional details of safety information to be collected. Conclusion Integration of multiple data sources in the SLS may provide more comprehensive safety information than usually collected in standard randomised controlled trials. Application of the principles of safety monitoring methodology from the SLS could facilitate safety monitoring processes for future pragmatic randomised controlled trials and yield important complementary safety and effectiveness data. © 2016 The Authors Pharmacoepidemiology and Drug Safety Published by John Wiley & Sons Ltd. PMID:27804174
Collier, Sue; Harvey, Catherine; Brewster, Jill; Bakerly, Nawar Diar; Elkhenini, Hanaa F; Stanciu, Roxana; Williams, Claire; Brereton, Jacqui; New, John P; McCrae, John; McCorkindale, Sheila; Leather, David
2017-03-01
The Salford Lung Study (SLS) programme, encompassing two phase III pragmatic randomised controlled trials, was designed to generate evidence on the effectiveness of a once-daily treatment for asthma and chronic obstructive pulmonary disease in routine primary care using electronic health records. The objective of this study was to describe and discuss the safety monitoring methodology and the challenges associated with ensuring patient safety in the SLS. Refinements to safety monitoring processes and infrastructure are also discussed. The study results are outside the remit of this paper. The results of the COPD study were published recently and a more in-depth exploration of the safety results will be the subject of future publications. The SLS used a linked database system to capture relevant data from primary care practices in Salford and South Manchester, two university hospitals and other national databases. Patient data were collated and analysed to create daily summaries that were used to alert a specialist safety team to potential safety events. Clinical research teams at participating general practitioner sites and pharmacies also captured safety events during routine consultations. Confidence in the safety monitoring processes over time allowed the methodology to be refined and streamlined without compromising patient safety or the timely collection of data. The information technology infrastructure also allowed additional details of safety information to be collected. Integration of multiple data sources in the SLS may provide more comprehensive safety information than usually collected in standard randomised controlled trials. Application of the principles of safety monitoring methodology from the SLS could facilitate safety monitoring processes for future pragmatic randomised controlled trials and yield important complementary safety and effectiveness data. © 2016 The Authors Pharmacoepidemiology and Drug Safety Published by John Wiley & Sons Ltd. © 2016 The Authors Pharmacoepidemiology and Drug Safety Published by John Wiley & Sons Ltd.
Performance results of cooperating expert systems in a distributed real-time monitoring system
NASA Technical Reports Server (NTRS)
Schwuttke, U. M.; Veregge, J. R.; Quan, A. G.
1994-01-01
There are numerous definitions for real-time systems, the most stringent of which involve guaranteeing correct system response within a domain-dependent or situationally defined period of time. For applications such as diagnosis, in which the time required to produce a solution can be non-deterministic, this requirement poses a unique set of challenges in dynamic modification of solution strategy that conforms with maximum possible latencies. However, another definition of real time is relevant in the case of monitoring systems where failure to supply a response in the proper (and often infinitesimal) amount of time allowed does not make the solution less useful (or, in the extreme example of a monitoring system responsible for detecting and deflecting enemy missiles, completely irrelevant). This more casual definition involves responding to data at the same rate at which it is produced, and is more appropriate for monitoring applications with softer real-time constraints, such as interplanetary exploration, which results in massive quantities of data transmitted at the speed of light for a number of hours before it even reaches the monitoring system. The latter definition of real time has been applied to the MARVEL system for automated monitoring and diagnosis of spacecraft telemetry. An early version of this system has been in continuous operational use since it was first deployed in 1989 for the Voyager encounter with Neptune. This system remained under incremental development until 1991 and has been under routine maintenance in operations since then, while continuing to serve as an artificial intelligence (AI) testbed in the laboratory. The system architecture has been designed to facilitate concurrent and cooperative processing by multiple diagnostic expert systems in a hierarchical organization. The diagnostic modules adhere to concepts of data-driven reasoning, constrained but complete nonoverlapping domains, metaknowledge of global consequences of anomalous data, hierarchical reporting of problems that extend beyond a single domain, and shared responsibility for problems that overlap domains. The system enables efficient diagnosis of complex system failures in real-time environments with high data volumes and moderate failure rates, as indicated by extensive performance measurements.
Integrating multiple satellite data for crop monitoring
USDA-ARS?s Scientific Manuscript database
Remote sensing provides a valuable data source for detecting crop types, monitoring crop condition and predicting crop yields from space. Routine and continuous remote sensing data are critical for agricultural research and operational applications. Since crop field dimensions tend to be relatively ...
Wright, Serena; Hull, Tom; Sivyer, David B.; Pearce, David; Pinnegar, John K.; Sayer, Martin D. J.; Mogg, Andrew O. M.; Azzopardi, Elaine; Gontarek, Steve; Hyder, Kieran
2016-01-01
Monitoring temperature of aquatic waters is of great importance, with modelled, satellite and in-situ data providing invaluable insights into long-term environmental change. However, there is often a lack of depth-resolved temperature measurements. Recreational dive computers routinely record temperature and depth, so could provide an alternate and highly novel source of oceanographic information to fill this data gap. In this study, a citizen science approach was used to obtain over 7,000 scuba diver temperature profiles. The accuracy, offset and lag of temperature records was assessed by comparing dive computers with scientific conductivity-temperature-depth instruments and existing surface temperature data. Our results show that, with processing, dive computers can provide a useful and novel tool with which to augment existing monitoring systems all over the globe, but especially in under-sampled or highly changeable coastal environments. PMID:27445104
Fillinger, Ulrike; Kannady, Khadija; William, George; Vanek, Michael J; Dongus, Stefan; Nyika, Dickson; Geissbühler, Yvonne; Chaki, Prosper P; Govella, Nico J; Mathenge, Evan M; Singer, Burton H; Mshinda, Hassan; Lindsay, Steven W; Tanner, Marcel; Mtasiwa, Deo; de Castro, Marcia C; Killeen, Gerry F
2008-01-01
Background As the population of Africa rapidly urbanizes, large populations could be protected from malaria by controlling aquatic stages of mosquitoes if cost-effective and scalable implementation systems can be designed. Methods A recently initiated Urban Malaria Control Programme in Dar es Salaam delegates responsibility for routine mosquito control and surveillance to modestly-paid community members, known as Community-Owned Resource Persons (CORPs). New vector surveillance, larviciding and management systems were designed and evaluated in 15 city wards to allow timely collection, interpretation and reaction to entomologic monitoring data using practical procedures that rely on minimal technology. After one year of baseline data collection, operational larviciding with Bacillus thuringiensis var. israelensis commenced in March 2006 in three selected wards. Results The procedures and staff management systems described greatly improved standards of larval surveillance relative to that reported at the outset of this programme. In the first year of the programme, over 65,000 potential Anopheles habitats were surveyed by 90 CORPs on a weekly basis. Reaction times to vector surveillance at observations were one day, week and month at ward, municipal and city levels, respectively. One year of community-based larviciding reduced transmission by the primary malaria vector, Anopheles gambiae s.l., by 31% (95% C.I. = 21.6–37.6%; p = 0.04). Conclusion This novel management, monitoring and evaluation system for implementing routine larviciding of malaria vectors in African cities has shown considerable potential for sustained, rapidly responsive, data-driven and affordable application. Nevertheless, the true programmatic value of larviciding in urban Africa can only be established through longer-term programmes which are stably financed and allow the operational teams and management infrastructures to mature by learning from experience. PMID:18218148
Reaping the space investment. [Shuttle era geosynchronous satellite based technological trends
NASA Technical Reports Server (NTRS)
Calio, A. J.
1979-01-01
By 1999 operational space systems will be implemented routinely on a worldwide scale in many areas vital to human survival and life quality. Geosynchronous-based monitoring and observation will be extensively used. The Shuttle era will bring in the capability to allow monitoring and identifying pollution sources which fail to stay within required limits. Remotely sensed data over land masses will provide needed facts on renewable and nonrenewable earth resources. New instruments and techniques will have been developed to provide geologists with clues to the declining number of deposits of fuels and minerals. Also, practical methods for predicting earthquakes will have been elaborated by 1999. Communications will see implementation of many of the technological goals of 1978.
[Monitoring and Modern Hemodynamic Concepts in Cardiac Anesthesia].
Heringlake, Matthias; Schmidt, Christian; Brandt, Sebastian
2018-05-01
Patients undergoing cardiac surgery are growing older, present with more comorbidities, and are frequently scheduled for more complex and prolonged surgical procedures. Routine application of neurological as well as extended hemodynamic monitoring combined with goal-directed perioperative hemodynamic optimization, targeting optimization of systemic and cerebral oxygen balance, show promise to reduce postoperative complications and to improve mortality in this high risk population. Expert recommendations suggest to avoid synthetic colloids for fluid optimization. Additionally, pathophysiological reasoning and results from recent trials suggest to start inotropic and vasoactive therapy primarily with non-adrenergic drugs like levosimendan and vasopressin and to add classical catecholamines like dobutamine and noradrenalin only if necessary to accomplish hemodynamic goals. Georg Thieme Verlag KG Stuttgart · New York.
Web-based video monitoring of CT and MRI procedures
NASA Astrophysics Data System (ADS)
Ratib, Osman M.; Dahlbom, Magdalena; Kho, Hwa T.; Valentino, Daniel J.; McCoy, J. Michael
2000-05-01
A web-based video transmission of images from CT and MRI consoles was implemented in an Intranet environment for real- time monitoring of ongoing procedures. Images captured from the consoles are compressed to video resolution and broadcasted through a web server. When called upon, the attending radiologists can view these live images on any computer within the secured Intranet network. With adequate compression, these images can be displayed simultaneously in different locations at a rate of 2 to 5 images/sec through standard LAN. The quality of the images being insufficient for diagnostic purposes, our users survey showed that they were suitable for supervising a procedure, positioning the imaging slices and for routine quality checking before completion of a study. The system was implemented at UCLA to monitor 9 CTs and 6 MRIs distributed in 4 buildings. This system significantly improved the radiologists productivity by saving precious time spent in trips between reading rooms and examination rooms. It also improved patient throughput by reducing the waiting time for the radiologists to come to check a study before moving the patient from the scanner.
Defining and classifying medical error: lessons for patient safety reporting systems.
Tamuz, M; Thomas, E J; Franchois, K E
2004-02-01
It is important for healthcare providers to report safety related events, but little attention has been paid to how the definition and classification of events affects a hospital's ability to learn from its experience. To examine how the definition and classification of safety related events influences key organizational routines for gathering information, allocating incentives, and analyzing event reporting data. In semi-structured interviews, professional staff and administrators in a tertiary care teaching hospital and its pharmacy were asked to describe the existing programs designed to monitor medication safety, including the reporting systems. With a focus primarily on the pharmacy staff, interviews were audio recorded, transcribed, and analyzed using qualitative research methods. Eighty six interviews were conducted, including 36 in the hospital pharmacy. Examples are presented which show that: (1) the definition of an event could lead to under-reporting; (2) the classification of a medication error into alternative categories can influence the perceived incentives and disincentives for incident reporting; (3) event classification can enhance or impede organizational routines for data analysis and learning; and (4) routines that promote organizational learning within the pharmacy can reduce the flow of medication error data to the hospital. These findings from one hospital raise important practical and research questions about how reporting systems are influenced by the definition and classification of safety related events. By understanding more clearly how hospitals define and classify their experience, we may improve our capacity to learn and ultimately improve patient safety.
Towards the Development of a Unified Distributed Date System for L1 Spacecraft
NASA Technical Reports Server (NTRS)
Lazarus, Alan J.; Kasper, Justin C.
2005-01-01
The purpose of this grant, 'Towards the Development of a Unified Distributed Data System for L1 Spacecraft', is to take the initial steps towards the development of a data distribution mechanism for making in-situ measurements more easily accessible to the scientific community. Our obligations as subcontractors to this grant are to add our Faraday Cup plasma data to this initial study and to contribute to the design of a general data distribution system. The year 1 objectives of the overall project as stated in the GSFC proposal are: 1) Both the rsync and Perl based data exchange tools will be fully developed and tested in our mixed, Unix, VMS, Windows and Mac OS X data service environment. Based on the performance comparisons, one will be selected and fully deployed. Continuous data exchange between all L1 solar wind monitors initiated. 2) Data version metadata will be agreed upon, fully documented, and deployed on our data sites. 3) The first version of the data description rules, encoded in a XML Schema, will be finalized. 4) Preliminary set of library routines will be collected, documentation standards and formats agreed on, and desirable routines that have not been implemented identified and assigned. 5) ViSBARD test site implemented to independently validate data mirroring procedures. The specific MIT tasks over the duration of this project are the following: a) implement mirroring service for WIND plasma data b) participate in XML Schema development c) contribute toward routine library.
Tack, Cornelius; Pohlmeier, Harald; Behnke, Thomas; Schmid, Volkmar; Grenningloh, Marco; Forst, Thomas; Pfützner, Andreas
2012-04-01
This multicenter study was conducted to evaluate the performance of five recently introduced blood glucose (BG) monitoring (BGM) devices under daily routine conditions in comparison with the YSI (Yellow Springs, OH) 2300 Stat Plus glucose analyzer. Five hundred one diabetes patients with experience in self-monitoring of BG were randomized to use three of five different BGM devices (FreeStyle Lite® [Abbott Diabetes Care Inc., Alameda, CA], FreeStyle Freedom Lite [Abbott Diabetes Care], OneTouch® UltraEasy® [LifeScan Inc., Milpitas, CA], Accu-Chek® Aviva [Roche Diagnostics, Mannheim, Germany], and Contour® [Bayer Vital GmbH, Leverkusen, Germany]) in a daily routine setting. All devices and strips were purchased from local regular distribution sources (pharmacies, four strip lots per device). The patients performed the finger prick and the glucose measurement on their own. In parallel, a healthcare professional performed the glucose assessment with the reference method (YSI 2300 Stat Plus). The primary objective was the comparison of the mean absolute relative differences (MARD). Secondary objectives were compliance with the International Organization for Standardization (ISO) accuracy criteria under these routine conditions and Clarke and Parkes Error Grid analyses. MARD ranged from 4.9% (FreeStyle Lite) to 9.7% (OneTouch UltraEasy). The ISO 15197:2003 requirements were fulfilled by the FreeStyle Lite (98.8%), FreeStyle Freedom Lite (97.5%), and Accu-Chek Aviva (97.0%), but not by the Contour (92.4%) and OneTouch UltraEasy (91.1%). The number of values in Zone A of the Clarke Error Grid analysis was highest for the FreeStyle Lite (98.8%) and lowest for the OneTouch Ultra Easy (90.4%). FreeStyle Lite, FreeStyle Freedom Lite, and Accu-Chek Aviva performed very well in this study with devices and strips purchased through regular distribution channels, with the FreeStyle Lite achieving the lowest MARD in this investigation.
Tack, Cornelius; Pohlmeier, Harald; Behnke, Thomas; Schmid, Volkmar; Grenningloh, Marco; Forst, Thomas
2012-01-01
Abstract Background This multicenter study was conducted to evaluate the performance of five recently introduced blood glucose (BG) monitoring (BGM) devices under daily routine conditions in comparison with the YSI (Yellow Springs, OH) 2300 Stat Plus glucose analyzer. Methods Five hundred one diabetes patients with experience in self-monitoring of BG were randomized to use three of five different BGM devices (FreeStyle Lite® [Abbott Diabetes Care Inc., Alameda, CA], FreeStyle Freedom Lite [Abbott Diabetes Care], OneTouch® UltraEasy® [LifeScan Inc., Milpitas, CA], Accu-Chek® Aviva [Roche Diagnostics, Mannheim, Germany], and Contour® [Bayer Vital GmbH, Leverkusen, Germany]) in a daily routine setting. All devices and strips were purchased from local regular distribution sources (pharmacies, four strip lots per device). The patients performed the finger prick and the glucose measurement on their own. In parallel, a healthcare professional performed the glucose assessment with the reference method (YSI 2300 Stat Plus). The primary objective was the comparison of the mean absolute relative differences (MARD). Secondary objectives were compliance with the International Organization for Standardization (ISO) accuracy criteria under these routine conditions and Clarke and Parkes Error Grid analyses. Results MARD ranged from 4.9% (FreeStyle Lite) to 9.7% (OneTouch UltraEasy). The ISO 15197:2003 requirements were fulfilled by the FreeStyle Lite (98.8%), FreeStyle Freedom Lite (97.5%), and Accu-Chek Aviva (97.0%), but not by the Contour (92.4%) and OneTouch UltraEasy (91.1%). The number of values in Zone A of the Clarke Error Grid analysis was highest for the FreeStyle Lite (98.8%) and lowest for the OneTouch Ultra Easy (90.4%). Conclusions FreeStyle Lite, FreeStyle Freedom Lite, and Accu-Chek Aviva performed very well in this study with devices and strips purchased through regular distribution channels, with the FreeStyle Lite achieving the lowest MARD in this investigation. PMID:22176154
Gloyd, Stephen; Wagenaar, Bradley H; Woelk, Godfrey B; Kalibala, Samuel
2016-01-01
HIV programme data from routine health information systems (RHIS) and personal health information (PHI) provide ample opportunities for secondary data analysis. However, these data pose unique opportunities and challenges for use in health system monitoring, along with process and impact evaluations. Analyses focused on retrospective case reviews of four of the HIV-related studies published in this JIAS supplement. We identify specific opportunities and challenges with respect to the secondary analysis of RHIS and PHI data. Challenges working with both HIV-related RHIS and PHI included missing, inconsistent and implausible data; rapidly changing indicators; systematic differences in the utilization of services; and patient linkages over time and different data sources. Specific challenges among RHIS data included numerous registries and indicators, inconsistent data entry, gaps in data transmission, duplicate registry of information, numerator-denominator incompatibility and infrequent use of data for decision-making. Challenges specific to PHI included the time burden for busy providers, the culture of lax charting, overflowing archives for paper charts and infrequent chart review. Many of the challenges that undermine effective use of RHIS and PHI data for analyses are related to the processes and context of collecting the data, excessive data requirements, lack of knowledge of the purpose of data and the limited use of data among those generating the data. Recommendations include simplifying data sources, analysis and reporting; conducting systematic data quality audits; enhancing the use of data for decision-making; promoting routine chart review linked with simple patient tracking systems; and encouraging open access to RHIS and PHI data for increased use.
Nucleic acids-based tools for ballast water surveillance, monitoring, and research
Understanding the risks of biological invasion posed by ballast water—whether in the context of compliance testing, routine monitoring, or basic research—is fundamentally an exercise in biodiversity assessment, and as such should take advantage of the best tools avail...
ERIC Educational Resources Information Center
Murphy, Debra A.; Marelich, William D.; Herbeck, Diane M.; Payne, Diana L.
2009-01-01
The influence of parenting skills on adolescent outcomes among children affected by maternal HIV/AIDS (N = 118, M age = 13) was investigated. Among families with more frequent family routines, over time adolescents showed lower rates of aggression, anxiety, worry, depression, conduct disorder, binge drinking, and increased self-concept. Among…
National survey of cardiologists' standard of practice for continuous ST-segment monitoring.
Sandau, Kristin E; Sendelbach, Sue; Frederickson, Joel; Doran, Karen
2010-03-01
Continuous ST-segment monitoring can be used to detect early and transient cardiac ischemia. The American Heart Association and American Association of Critical-Care Nurses recommend its use among specific patients, but such monitoring is routine practice in only about half of US hospitals. To determine cardiologists' awareness and practice standards regarding continuous ST-segment monitoring and the physicians' perceptions of appropriate patient selection, benefits and barriers, and usefulness of this technology. An electronic survey was sent to a random sample of 915 US cardiologists from a pool of 4985 certified cardiologists. Of 200 responding cardiologists, 55% were unaware of the consensus guidelines. Of hospitals where respondents admitted patients, 49% had a standard of practice for using continuous ST-segment monitoring for cardiac patients. Most cardiologists agreed or strongly agreed that patients in the cardiovascular laboratory (87.5%) and intensive care unit (80.5%) should have such monitoring. Cardiologists routinely ordered ST monitoring for patients with acute coronary syndrome (67%) and after percutaneous coronary intervention (60%). The primary factor associated with higher perceptions for benefits, clinical usefulness, and past use of continuous ST-segment monitoring was whether or not hospitals in which cardiologists practiced had a standard of practice for using this monitoring. A secondary factor was awareness of published consensus guidelines for such monitoring. Respondents (55%) were unaware of published monitoring guidelines. Hospital leaders could raise awareness by multidisciplinary review of evidence and possibly incorporating continuous ST-segment monitoring into hospitals' standards of practice.
TOPEX/Poseidon precision orbit determination production and expert system
NASA Technical Reports Server (NTRS)
Putney, Barbara; Zelensky, Nikita; Klosko, Steven
1993-01-01
TOPEX/Poseidon (T/P) is a joint mission between NASA and the Centre National d'Etudes Spatiales (CNES), the French Space Agency. The TOPEX/Poseidon Precision Orbit Determination Production System (PODPS) was developed at Goddard Space Flight Center (NASA/GSFC) to produce the absolute orbital reference required to support the fundamental ocean science goals of this satellite altimeter mission within NASA. The orbital trajectory for T/P is required to have a RMS accuracy of 13 centimeters in its radial component. This requirement is based on the effective use of the satellite altimetry for the isolation of absolute long-wavelength ocean topography important for monitoring global changes in the ocean circulation system. This orbit modeling requirement is at an unprecedented accuracy level for this type of satellite. In order to routinely produce and evaluate these orbits, GSFC has developed a production and supporting expert system. The PODPS is a menu driven system allowing routine importation and processing of tracking data for orbit determination, and an evaluation of the quality of the orbit so produced through a progressive series of tests. Phase 1 of the expert system grades the orbit and displays test results. Later phases undergoing implementation, will prescribe corrective actions when unsatisfactory results are seen. This paper describes the design and implementation of this orbit determination production system and the basis for its orbit accuracy assessment within the expert system.
Scalable Integrated Multi-Mission Support System Simulator Release 3.0
NASA Technical Reports Server (NTRS)
Kim, John; Velamuri, Sarma; Casey, Taylor; Bemann, Travis
2012-01-01
The Scalable Integrated Multi-mission Support System (SIMSS) is a tool that performs a variety of test activities related to spacecraft simulations and ground segment checks. SIMSS is a distributed, component-based, plug-and-play client-server system useful for performing real-time monitoring and communications testing. SIMSS runs on one or more workstations and is designed to be user-configurable or to use predefined configurations for routine operations. SIMSS consists of more than 100 modules that can be configured to create, receive, process, and/or transmit data. The SIMSS/GMSEC innovation is intended to provide missions with a low-cost solution for implementing their ground systems, as well as significantly reducing a mission s integration time and risk.
Application of laser Doppler velocimeter to chemical vapor laser system
NASA Technical Reports Server (NTRS)
Gartrell, Luther R.; Hunter, William W., Jr.; Lee, Ja H.; Fletcher, Mark T.; Tabibi, Bagher M.
1993-01-01
A laser Doppler velocimeter (LDV) system was used to measure iodide vapor flow fields inside two different-sized tubes. Typical velocity profiles across the laser tubes were obtained with an estimated +/-1 percent bias and +/-0.3 to 0.5 percent random uncertainty in the mean values and +/-2.5 percent random uncertainty in the turbulence-intensity values. Centerline velocities and turbulence intensities for various longitudinal locations ranged from 13 to 17.5 m/sec and 6 to 20 percent, respectively. In view of these findings, the effects of turbulence should be considered for flow field modeling. The LDV system provided calibration data for pressure and mass flow systems used routinely to monitor the research laser gas flow velocity.
Beussink, Amy M.; Burnich, Michael R.
2009-01-01
Lake Houston, a reservoir impounded in 1954 by the City of Houston, Texas, is a primary source of drinking water for Houston and surrounding areas. The U.S. Geological Survey, in cooperation with the City of Houston, developed a continuous water-quality monitoring network to track daily changes in water quality in the southwestern quadrant of Lake Houston beginning in 2006. Continuous water-quality data (the physiochemical properties water temperature, specific conductance, pH, dissolved oxygen concentration, and turbidity) were collected from Lake Houston to characterize the in-lake processes that affect water quality. Continuous data were collected hourly from mobile, multi-depth monitoring stations developed and constructed by the U.S. Geological Survey. Multi-depth monitoring stations were installed at five sites in three general locations in the southwestern quadrant of the lake. Discrete water-quality data (samples) were collected routinely (once or twice each month) at all sites to characterize the chemical and biological (phytoplankton and bacteria) response to changes in the continuous water-quality properties. Physiochemical properties (the five continuously monitored plus transparency) were measured in the field when samples were collected. In addition to the routine samples, discrete water-quality samples were collected synoptically (one or two times during the study period) at all sites to determine the presence and levels of selected constituents not analyzed in routine samples. Routine samples were measured or analyzed for acid neutralizing capacity; selected major ions and trace elements (calcium, silica, and manganese); nutrients (filtered and total ammonia nitrogen, filtered nitrate plus nitrite nitrogen, total nitrate nitrogen, filtered and total nitrite nitrogen, filtered and total orthophosphate phosphorus, total phosphorus, total nitrogen, total organic carbon); fecal indicator bacteria (total coliform and Escherichia coli); sediment (suspended-sediment concentration and loss-on-ignition); actinomycetes bacteria; taste-and-odor-causing compounds (2-methylisoborneol and geosmin); cyanobacterial toxins (total microcystins); and phytoplankton abundance, biovolume, and community composition (taxonomic identification to genus). Synoptic samples were analyzed for major ions, trace elements, wastewater indicators, pesticides, volatile organic compounds, and carbon. The analytical data are presented in tables by type (continuous, discrete routine, discrete synoptic) and listed by station number. Continuously monitored properties (except pH) also are displayed graphically.
A fault-tolerant intelligent robotic control system
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Tso, Kam Sing
1993-01-01
This paper describes the concept, design, and features of a fault-tolerant intelligent robotic control system being developed for space and commercial applications that require high dependability. The comprehensive strategy integrates system level hardware/software fault tolerance with task level handling of uncertainties and unexpected events for robotic control. The underlying architecture for system level fault tolerance is the distributed recovery block which protects against application software, system software, hardware, and network failures. Task level fault tolerance provisions are implemented in a knowledge-based system which utilizes advanced automation techniques such as rule-based and model-based reasoning to monitor, diagnose, and recover from unexpected events. The two level design provides tolerance of two or more faults occurring serially at any level of command, control, sensing, or actuation. The potential benefits of such a fault tolerant robotic control system include: (1) a minimized potential for damage to humans, the work site, and the robot itself; (2) continuous operation with a minimum of uncommanded motion in the presence of failures; and (3) more reliable autonomous operation providing increased efficiency in the execution of robotic tasks and decreased demand on human operators for controlling and monitoring the robotic servicing routines.
Implementation Science Supports Core Clinical Competencies: An Overview and Clinical Example.
Kirchner, JoAnn E; Woodward, Eva N; Smith, Jeffrey L; Curran, Geoffrey M; Kilbourne, Amy M; Owen, Richard R; Bauer, Mark S
2016-12-08
Instead of asking clinicians to work faster or longer to improve quality of care, implementation science provides another option. Implementation science is an emerging interdisciplinary field dedicated to studying how evidence-based practice can be adopted into routine clinical care. This article summarizes principles and methods of implementation science, illustrates how they can be applied in a routine clinical setting, and highlights their importance to practicing clinicians as well as clinical trainees. A hypothetical clinical case scenario is presented that explains how implementation science improves clinical practice. The case scenario is also embedded within a real-world implementation study to improve metabolic monitoring for individuals prescribed antipsychotics. Context, recipient, and innovation (ie, the evidence-based practice) factors affected improvement of metabolic monitoring. To address these factors, an external facilitator and a local quality improvement team developed an implementation plan involving a multicomponent implementation strategy that included education, performance reports, and clinician follow-up. The clinic remained compliant with recommended metabolic monitoring at 1-year follow up. Implementation science improves clinical practice by addressing context, recipient, and innovation factors and uses this information to develop and utilize specific strategies that improve clinical practice. It also enriches clinical training, aligning with core competencies by the Accreditation Council for Graduate Medical Education and American Boards of Medical Specialties. By learning how to change clinical practice through implementation strategies, clinicians are more able to adapt in complex systems of practice. © Copyright 2016 Physicians Postgraduate Press, Inc.
Improved Testing Capability and Adaptability Through the Use of Wireless Sensors
NASA Technical Reports Server (NTRS)
Solano, Wanda M.
2003-01-01
From the first Saturn V rocket booster (S-II-T) testing in 1966 and the routine Space Shuttle Main Engine (SSME) testing beginning in 1975, to more recent test programs such as the X-33 Aerospike Engine, the Integrated Powerhead Development (IPD) program, and the Hybrid Sounding Rocket (HYSR), Stennis Space Center (SSC) continues to be a premier location for conducting large-scale testing. Central to each test program is the capability for sensor systems to deliver reliable measurements and high quality data, while also providing a means to monitor the test stand area to the highest degree of safety and sustainability. Sensor wiring is routed along piping and through cable trenches, making its way from the engine test area, through the test stand area and to the signal conditioning building before final transfer to the test control center. When sensor requirements lie outside the reach of the routine sensor cable routing, the use of wireless sensor networks becomes particularly attractive due to their versatility and ease of installation. As part of an on-going effort to enhance the testing capabilities of Stennis Space Center, the Test Technology and Development group has found numerous applications for its sensor-adaptable wireless sensor suite. While not intended for critical engine measurements or control loops, in-house hardware and software development of the sensor suite can provide improved testing capability for a range of applications including the safety monitoring of propellant storage barrels and as an experimental test-bed for embedded health monitoring paradigms.
Caduff, Andreas; Mueller, Martin; Megej, Alexander; Dewarrat, Francois; Suri, Roland E; Klisic, Jelena; Donath, Marc; Zakharov, Pavel; Schaub, Dominik; Stahel, Werner A; Talary, Mark S
2011-05-15
The Multisensor Glucose Monitoring System (MGMS) features non invasive sensors for dielectric characterisation of the skin and underlying tissue in a wide frequency range (1 kHz-100 MHz, 1 and 2 GHz) as well as optical characterisation. In this paper we describe the results of using an MGMS in a miniaturised housing with fully integrated sensors and battery. Six patients with Type I Diabetes Mellitus (age 44±16 y; BMI 24.1±1.3 kg/m(2), duration of diabetes 27±12 y; HbA1c 7.3±1.0%) wore a single Multisensor at the upper arm position and performed a total of 45 in-clinic study days with 7 study days per patient on average (min. 5 and max. 10). Glucose changes were induced either orally or by i.v. glucose administration and the blood glucose was measured routinely. Several prospective data evaluation routines were applied to evaluate the data. The results are shown using one of the restrictive data evaluation routines, where measurements from the first 22 study days were used to train a linear regression model. The global model was then prospectively applied to the data of the remaining 23 study days to allow for an external validation of glucose prediction. The model application yielded a Mean Absolute Relative Difference of 40.8%, a Mean Absolute Difference of 51.9 mg dL(-1), and a correlation of 0.84 on average per study day. The Clarke error grid analyses showed 89.0% in A+B, 4.5% in C, 4.6% in D and 1.9% in the E region. Prospective application of a global, purely statistical model, demonstrates that glucose variations can be tracked non invasively by the MGMS in most cases under these conditions. Copyright © 2011 Elsevier B.V. All rights reserved.
SU-E-T-473: A Patient-Specific QC Paradigm Based On Trajectory Log Files and DICOM Plan Files
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeMarco, J; McCloskey, S; Low, D
Purpose: To evaluate a remote QC tool for monitoring treatment machine parameters and treatment workflow. Methods: The Varian TrueBeamTM linear accelerator is a digital machine that records machine axis parameters and MLC leaf positions as a function of delivered monitor unit or control point. This information is saved to a binary trajectory log file for every treatment or imaging field in the patient treatment session. A MATLAB analysis routine was developed to parse the trajectory log files for a given patient, compare the expected versus actual machine and MLC positions as well as perform a cross-comparison with the DICOM-RT planmore » file exported from the treatment planning system. The parsing routine sorts the trajectory log files based on the time and date stamp and generates a sequential report file listing treatment parameters and provides a match relative to the DICOM-RT plan file. Results: The trajectory log parsing-routine was compared against a standard record and verify listing for patients undergoing initial IMRT dosimetry verification and weekly and final chart QC. The complete treatment course was independently verified for 10 patients of varying treatment site and a total of 1267 treatment fields were evaluated including pre-treatment imaging fields where applicable. In the context of IMRT plan verification, eight prostate SBRT plans with 4-arcs per plan were evaluated based on expected versus actual machine axis parameters. The average value for the maximum RMS MLC error was 0.067±0.001mm and 0.066±0.002mm for leaf bank A and B respectively. Conclusion: A real-time QC analysis program was tested using trajectory log files and DICOM-RT plan files. The parsing routine is efficient and able to evaluate all relevant machine axis parameters during a patient treatment course including MLC leaf positions and table positions at time of image acquisition and during treatment.« less
NASA Astrophysics Data System (ADS)
Khokhlova, L. A.; Seleznev, A. I.; Zhdanov, D. S.; Zemlyakov, I. Yu; Kiseleva, E. Yu
2016-01-01
The problem of monitoring fetal health is topical at the moment taking into account a reduction in the level of fertile-age women's health and changes in the concept of perinatal medicine with reconsideration of live birth criteria. Fetal heart rate monitoring is a valuable means of assessing fetal health during pregnancy. The routine clinical measurements are usually carried out by the means of ultrasound cardiotocography. Although the cardiotocography monitoring provides valuable information on the fetal health status, the high quality ultrasound devices are expensive, they are not available for home care use. The recommended number of measurement is also limited. The passive and fully non-invasive acoustic recording provides an alternative low-cost measurement method. The article describes a device for fetal and maternal health monitoring by analyzing the frequency and periodicity of heart beats by means of acoustic signal received on the maternal abdomen. Based on the usage of this device a phonocardiographic fetal telemedicine system, which will allow to reduce the antenatal fetal mortality rate significantly due to continuous monitoring over the state of fetus regardless of mother's location, can be built.
Real-Time Monitoring of Vaccination Campaign Performance Using Mobile Phones - Nepal, 2016.
Oh, David H; Dabbagh, Alya; Goodson, James L; Strebel, Peter M; Thapa, Sanjita; Giri, Jagat Narain; Shakya, Sagar Ratna; Khanal, Sudhir
2016-10-07
In 2012, the Global Vaccine Action Plan* established a goal to achieve measles and rubella elimination in five of the six World Health Organization (WHO) regions (194 countries) by 2020 (1). Measles elimination strategies aim to achieve ≥95% coverage with 2 routine doses of measles-containing vaccine (2), and implement supplementary immunization activities (SIAs) † in settings where routine coverage is low or where there are subpopulations at high risk. To ensure SIA quality and to achieve ≥95% SIA coverage nationally, rapid convenience monitoring (RCM) is used during or immediately after SIAs (3,4). The objective of RCM is to find unvaccinated children and to identify reasons for nonvaccination in areas with persons at high risk, to enable immediate implementation of corrective actions (e.g., reassigning teams to poorly vaccinated areas, modifying the timing of vaccination, or conducting mop-up vaccination activities). This report describes pilot testing of RCM using mobile phones (RCM-MP) during the second phase of an SIA in Nepal in 2016. Use of RCM-MP resulted in 87% timeliness and 94% completeness of data reporting and found that, although 95% of children were vaccinated, 42% of areas required corrective vaccination activities. RCM-MP challenges included connecting to mobile networks, small phone screen size, and capturing Global Positioning System (GPS) coordinates. Nonetheless, use of RCM-MP led to faster data transmission, analysis, and decision-making and to increased accountability among levels of the health system.
ERIC Educational Resources Information Center
Poon, Brenda T.; Simmons, Noreen R.
2016-01-01
Population-based outcome monitoring could provide useful information about factors that differentially influence the developmental trajectories of deaf or hard-of-hearing children. A strong basis for population-based outcome monitoring is a coordinated, longitudinal data collection, and management infrastructure that includes quality local…
A Spike Cocktail Approach to Improve Microbial Performance ...
Water reuse, via either centralized treatment of traditional wastewater or decentralized treatment and on-site reuse, is becoming an increasingly important element of sustainable water management. Despite advances in waterborne pathogen detection methods, low and highly variable pathogen levels limit their utility for routine evaluation of health risks in water reuse systems. Therefore, there is a need to improve our understanding of the linkage between pathogens and more readily measured process indicators during treatment. This paper describes an approach for constructing spiking experiments to relate the behavior of viral, bacterial, and protozoan pathogens with relevant process indicators. General issues are reviewed, and the spiking protocol is applied as a case study example to improve microbial performance monitoring and health risk evaluation in a water reuse system. This approach provides a foundation for the development of novel approaches to improve real or near-real time performance monitoring of water recycling systems. This manuscrupt details an approach for developing "spike cocktail", a mixture of microorganisms that can be used to evaluate the performance of engineered and natural systems.
Design and Implementation of a Coastal-Mounted Sensor for Oil Film Detection on Seawater
Hou, Yongchao; Li, Ying; Liu, Yu; Wang, Tong
2017-01-01
The routine surveillance of oil spills in major ports is important. However, existing techniques and sensors are unable to trace oil and micron-thin oil films on the surface of seawater. Therefore, we designed and studied a coastal-mounted sensor, using ultraviolet-induced fluorescence and fluorescence-filter systems (FFSs), to monitor oil spills and overcome the disadvantages of traditional surveillance systems. Using seawater from the port of Lingshui (Yellow Sea, China) and six oil samples of different types, we found that diesel oil’s relative fluorescence intensity (RFI) was significantly higher than those of heavy fuel and crude oils in the 180–300 nm range—in the 300–400 nm range, the RFI value of diesel is far lower. The heavy fuel and crude oils exhibited an opposite trend in their fluorescence spectra. A photomultiplier tube, employed as the fluorescence detection unit, efficiently monitored different oils on seawater in field experiments. On-site tests indicated that this sensor system could be used as a coastal-mounted early-warning detection system for oil spills. PMID:29283412
Kazi, A M; Ali, M; K, Ayub; Kalimuddin, H; Zubair, K; Kazi, A N; A, Artani; Ali, S A
2017-11-01
The addition of Global Positioning System (GPS) to a mobile phone makes it a very powerful tool for surveillance and monitoring coverage of health programs. This technology enables transfer of data directly into computer applications and cross-references to Geographic Information Systems (GIS) maps, which enhances assessment of coverage and trends. Utilization of these systems in low and middle income countries is currently limited, particularly for immunization coverage assessments and polio vaccination campaigns. We piloted the use of this system and discussed its potential to improve the efficiency of field-based health providers and health managers for monitoring of the immunization program. Using "30×7" WHO sampling technique, a survey of children less than five years of age was conducted in random clusters of Karachi, Pakistan in three high risk towns where a polio case was detected in 2011. Center point of the cluster was calculated by the application on the mobile. Data and location coordinates were collected through a mobile phone. This data was linked with an automated mHealth based monitoring system for monitoring of Supplementary Immunization Activities (SIAs) in Karachi. After each SIA, a visual report was generated according to the coordinates collected from the survey. A total of 3535 participants consented to answer to a baseline survey. We found that the mobile phones incorporated with GIS maps can improve efficiency of health providers through real-time reporting and replacing paper based questionnaire for collection of data at household level. Visual maps generated from the data and geospatial analysis can also give a better assessment of the immunization coverage and polio vaccination campaigns. The study supports a model system in resource constrained settings that allows routine capture of individual level data through GPS enabled mobile phone providing actionable information and geospatial maps to local public health managers, policy makers and study staff monitoring immunization coverage. Copyright © 2017 Elsevier B.V. All rights reserved.
The National Ambient Air Monitoring Stategy: Rethinking the Role of National Networks
A current re-engineering of the United States routine ambient monitoring networks intended to improve the balance in addressing both regulatory and scientific objectives is addressed in this paper. Key attributes of these network modifications include the addition of collocated ...
NASA Astrophysics Data System (ADS)
Gargallo, Ana; Arines, Justo
2014-08-01
We have adapted low cost webcams to the slit lamps objectives with the aim of improving contact lens fitting practice. With this solution we obtain good quality pictures and videos, we also recorded videos of eye examination, evaluation routines of contact lens fitting, and the final practice exam of our students. In addition, the video system increases the interactions between students because they could see what their colleagues are doing and take conscious of their mistakes, helping and correcting each others. We think that the proposed system is a low cost solution for supporting the training in contact lens fitting practice.
Pilot interaction with automated airborne decision making systems
NASA Technical Reports Server (NTRS)
Hammer, John M.; Wan, C. Yoon; Vasandani, Vijay
1987-01-01
The current research is focused on detection of human error and protection from its consequences. A program for monitoring pilot error by comparing pilot actions to a script was described. It dealt primarily with routine errors (slips) that occurred during checklist activity. The model to which operator actions were compared was a script. Current research is an extension along these two dimensions. The ORS fault detection aid uses a sophisticated device model rather than a script. The newer initiative, the model-based and constraint-based warning system, uses an even more sophisticated device model and is to prevent all types of error, not just slips or bad decision.
Nishizawa, Masafumi; Hoshide, Satoshi; Okawara, Yukie; Matsuo, Takefumi; Kario, Kazuomi
2017-01-01
At the time of the Great East Japan earthquake and tsunami (March 2011), the authors developed a web-based information and communications technology (ICT)-based blood pressure (BP) monitoring system (the Disaster CArdiovascular Prevention [DCAP] Network) and introduced it in an area that was catastrophically damaged (Minamisanriku town) to help control the survivors' BP. Using this system, home BP (HBP) was monitored and the data were automatically transmitted to a central computer database and to the survivors' attending physicians. The study participants, 341 hypertensive patients, continued to use this system for 4 years after the disaster and all of the obtained HBP readings were analyzed. This DCAP HBP-guided approach helped achieve a decrease in the participants' HBPs (initial average: 151.3±20.0/86.9±10.2 mm Hg to 120.2±12.1/70.8±10.2 mm Hg) over the 4 years. In addition, the amplitude of seasonal BP variation was suppressed and the duration from the summer lowest HBP values to the winter peak HBP values was gradually prolonged. This ICT-based approach was useful to achieve strict HBP control and minimize the seasonal BP variation even in a catastrophically damaged area during a 4-year period after the disaster, suggesting that this approach could be a routine way to monitor BP in the community. ©2016 Wiley Periodicals, Inc.
Environmental surveillance master sampling schedule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bisping, L.E.
This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of themore » onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.« less
Zorn, Julia; Ritter, Bärbel; Miller, Manuel; Kraus, Monika; Northrup, Emily; Brielmeier, Markus
2017-06-01
One limitation to housing rodents in individually ventilated cages (IVCs) is the ineffectiveness of traditional health monitoring programs that test soiled bedding sentinels every quarter. Aerogen transmission does not occur with this method. Moreover, the transmission of numerous pathogens in bedding is uncertain, and sentinel susceptibility to various pathogens varies. A novel method using particle collection from samples of exhaust air was developed in this study which was also systematically compared with routine health monitoring using soiled bedding sentinels. We used our method to screen these samples for the presence of murine norovirus (MNV), a mouse pathogen highly prevalent in laboratory animal facilities. Exhaust air particles from prefilters of IVC racks with known MNV prevalence were tested by quantitative reverse transcription polymerase chain reaction (RT-qPCR). MNV was detected in exhaust air as early as one week with one MNV-positive cage per rack, while sentinels discharged MNV RNA without seroconverting. MNV was reliably and repeatedly detected in particles collected from samples of exhaust air in all seven of the three-month sampling rounds, with increasing MNV prevalence, while sentinels only seroconverted in one round. Under field conditions, routine soiled bedding sentinel health monitoring in our animal facility failed to identify 67% ( n = 85) of positive samples by RT-qPCR of exhaust air particles. Thus, this method proved to be highly sensitive and superior to soiled bedding sentinels in the reliable detection of MNV. These results represent a major breakthrough in hygiene monitoring of rodent IVC systems and contribute to the 3R principles by reducing the number of animals used and by improving experimental conditions.
Libert, X; Chasseur, C; Packeu, A; Bureau, F; Roosens, N H; De Keersmaecker, S J C
2016-02-01
Exophiala jeanselmei is an opportunistic pathogenic black yeast growing in humid environments such as water reservoirs of air-conditioning systems. Because this fungal contaminant could be vaporized into the air and subsequently cause health problems, its monitoring is recommended. Currently, this monitoring is based on culture and microscopic identification which are complex, sometimes ambiguous and time-demanding, i.e., up to 21 days. Therefore, molecular, culture-independent methods could be more advantageous for the monitoring of E. jeanselmei. In this study, we developed a SYBR®green real-time PCR assay based on the internal transcribed spacer 2 from the 18S ribosomal DNA complex for the specific detection of E. jeanselmei. The selectivity (100 %), PCR efficiency (95.5 %), dynamic range and repeatability of this qPCR assay were subsequently evaluated. The limit of detection for this qPCR assay was determined to be 1 copy of genomic DNA of E. jeanselmei. Finally, water samples collected from cooling reservoirs were analyzed using this qPCR assay to deliver a proof of concept for the molecular detection of E. jeanselmei in environmental samples. The results obtained by molecular analysis were compared with those of classical methods (i.e., culture and microscopic identification) used in routine analysis and were 100 % matching. This comparison demonstrated that this SYBR®green qPCR assay can be used as a molecular alternative for monitoring and routine investigation of samples contaminated by E. jeanselmei, while eliminating the need for culturing and thereby considerably decreasing the required analysis time to 2 days.
Angelov, D; O'Brien, J; Kavanagh, P
2013-03-01
1-(2-Thienyl)-2-(methylamino)propane (methiopropamine, MPA), the thiophene analogue of methamphetamine, has recently appeared on a number of websites offering 'legal highs' for sale and has also been reported as a new psychoactive substance by the European Monitoring Centre for Drugs and Drugs Addiction (EMCDDA) Early Warning System. The drug is currently not controlled in the European Union (EU) but it would be expected that forensic laboratories will encounter it during routine analysis. As no reference standard was available, we have established a three-step protocol for its synthesis. We have also synthesized its 3-thienyl isomer and have established that this is separable from methiopropamine by gas chromatography using one of our routine protocols. The synthetic methodology presented here could be readily extended to the syntheses of analogous compounds. Copyright © 2011 John Wiley & Sons, Ltd.
Prodinger, Birgit; Reinhardt, Jan D; Selb, Melissa; Stucki, Gerold; Yan, Tiebin; Zhang, Xia; Li, Jianan
2016-06-13
A national, multi-phase, consensus process to develop simple, intuitive descriptions of International Classification of Functioning, Disability and Health (ICF) categories contained in the ICF Generic and Rehabilitation Sets, with the aim of enhancing the utility of the ICF in routine clinical practice, is presented in this study. A multi-stage, national, consensus process was conducted. The consensus process involved 3 expert groups and consisted of a preparatory phase, a consensus conference with consecutive working groups and 3 voting rounds (votes A, B and C), followed by an implementation phase. In the consensus conference, participants first voted on whether they agreed that an initially developed proposal for simple, intuitive descriptions of an ICF category was in fact simple and intuitive. The consensus conference was held in August 2014 in mainland China. Twenty-one people with a background in physical medicine and rehabilitation participated in the consensus process. Four ICF categories achieved consensus in vote A, 16 in vote B, and 8 in vote C. This process can be seen as part of a larger effort towards the system-wide implementation of the ICF in routine clinical and rehabilitation practice to allow for the regular and comprehensive evaluation of health outcomes most relevant for the monitoring of quality of care.
Cycles in metabolism and heat loss
NASA Technical Reports Server (NTRS)
Annis, J. F.; Troutman, S. J.; Webb, P.
1974-01-01
Using calorimetric techniques, subjects' metabolism, thermoregulation, and body temperatures were monitored continuously for 24-hour days, using three types of experimental routines. A water cooling garment (WCG) was used for direct calorimetry, while partitional calorimetry was used to establish a non-suited comparison for one of the routines. In this replicated routine, called the quiet day, the subjects were sedentary throughout the daytime hours and slept normally at night. Results indicate that the WCG may act to reduce 24-hour total oxygen consumption (VO2) or heat production, possibly due to the lowered energy cost of thermoregulation.
Bellazzi, Riccardo; Sacchi, Lucia; Caffi, Ezio; de Vincenzi, Amedeo; Nai, Maurizio; Manicone, Francesco; Larizza, Cristiana; Bellazzi, Roberto
2012-05-01
In this paper we present the clinical deployment and evaluation of a computerized system, EMOSTAT, aimed at improving the quality of hemodialysis sessions. EMOSTAT automatically imports data from the hemodialysis monitoring software tools and analyzes the delivered treatment looking at six clinically relevant parameters. Failures-to-adhere (FtAs) to the planned treatment are detected and reported to the care-givers. EMOSTAT has been used for more than seven years in the management of a dialysis service located in Mede, Italy. A total of 72 patients were monitored and 21251 dialyses were collected. Data analysis is performed on the periods 2002-2005 and 2005-2008, corresponding to two different software releases. The system had been exploited into everyday clinical practice for the entire considered period. The number of FtAs significantly decreased along the first period: the bulk blood flow FtAs decreased after the introduction of the system. Hemodialysis sessions lasted longer in the second period. Co-occurring FtAs, highlighting the presence of complex FtAs patterns, were also detected. EMOSTAT provides an effective way to re-focus the attention of the dialysis department on the treatment plan and on its implementation. The automatic data collection and the design philosophy of EMOSTAT allowed the routine use of the system. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Technical Manual for the Geospatial Stream Flow Model (GeoSFM)
Asante, Kwabena O.; Artan, Guleid A.; Pervez, Md Shahriar; Bandaragoda, Christina; Verdin, James P.
2008-01-01
The monitoring of wide-area hydrologic events requires the use of geospatial and time series data available in near-real time. These data sets must be manipulated into information products that speak to the location and magnitude of the event. Scientists at the U.S. Geological Survey Earth Resources Observation and Science (USGS EROS) Center have implemented a hydrologic modeling system which consists of an operational data processing system and the Geospatial Stream Flow Model (GeoSFM). The data processing system generates daily forcing evapotranspiration and precipitation data from various remotely sensed and ground-based data sources. To allow for rapid implementation in data scarce environments, widely available terrain, soil, and land cover data sets are used for model setup and initial parameter estimation. GeoSFM performs geospatial preprocessing and postprocessing tasks as well as hydrologic modeling tasks within an ArcView GIS environment. The integration of GIS routines and time series processing routines is achieved seamlessly through the use of dynamically linked libraries (DLLs) embedded within Avenue scripts. GeoSFM is run operationally to identify and map wide-area streamflow anomalies. Daily model results including daily streamflow and soil water maps are disseminated through Internet map servers, flood hazard bulletins and other media.
Tappis, Hannah; Doocy, Shannon; Haskew, Christopher; Wilkinson, Caroline; Oman, Allison; Spiegel, Paul
2012-06-01
The United Nations High Commissioner for Refugees (UNHCR) Health Information System is a primary source of routine nutrition program data and provides a comprehensive assessment of UNHCR selective feeding programs in more than 90 refugee camps in 18 countries worldwide. To evaluate the coverage and effectiveness of UNHCR supplementary and therapeutic feeding programs for malnourished children under 5 years of age in Kenya and Tanzania refugee camps. Analysis of Kenya and Tanzania refugee camp population, growth monitoring and nutrition program data from the UNHCR Health Information System. UNHCR-supported implementing partners in Kenya and Tanzania admitted nearly 45,000 malnourished refugee children in selective feeding programs between January 2006 and May 2009. Average recovery rates of 77.1% and 84.6% in the therapeutic and supplementary programs, respectively, mortality rates of less than 1%, and average readmission below 5% suggest that feeding programs had a beneficial effect on enrolled children. Increasing admission and enrollment in supplementary feeding programs was successful in preventing cases of severe malnutrition in some camps. Further attention to these camps would be likely to yield sizeable benefits in terms of absolute reductions in malnutrition prevalence and mortality rates.
Crack propagation analysis using acoustic emission sensors for structural health monitoring systems.
Kral, Zachary; Horn, Walter; Steck, James
2013-01-01
Aerospace systems are expected to remain in service well beyond their designed life. Consequently, maintenance is an important issue. A novel method of implementing artificial neural networks and acoustic emission sensors to form a structural health monitoring (SHM) system for aerospace inspection routines was the focus of this research. Simple structural elements, consisting of flat aluminum plates of AL 2024-T3, were subjected to increasing static tensile loading. As the loading increased, designed cracks extended in length, releasing strain waves in the process. Strain wave signals, measured by acoustic emission sensors, were further analyzed in post-processing by artificial neural networks (ANN). Several experiments were performed to determine the severity and location of the crack extensions in the structure. ANNs were trained on a portion of the data acquired by the sensors and the ANNs were then validated with the remaining data. The combination of a system of acoustic emission sensors, and an ANN could determine crack extension accurately. The difference between predicted and actual crack extensions was determined to be between 0.004 in. and 0.015 in. with 95% confidence. These ANNs, coupled with acoustic emission sensors, showed promise for the creation of an SHM system for aerospace systems.
Embedded programmable blood pressure monitoring system
NASA Astrophysics Data System (ADS)
Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk
2010-02-01
A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.
International Radiation Monitoring and Information System (IRMIS)
NASA Astrophysics Data System (ADS)
Mukhopadhyay, Sanjoy; Baciu, Florian; Stowisek, Jan; Saluja, Gurdeep; Kenny, Patrick; Albinet, Franck
2017-09-01
This article describes the International Radiation Monitoring Information System (IRMIS) which was developed by the International Atomic Energy Agency (IAEA) with the goal to provide Competent Authorities, the IAEA and other international organizations with a client server based web application to share and visualize large quantities of radiation monitoring data. The data maps the areas of potential impact that can assist countries to take appropriate protective actions in an emergency. Ever since the Chernobyl nuclear power plant accident in April of 19861 European Community (EC) has worked towards collecting routine environmental radiological monitoring data from national networked monitoring systems. European Radiological Data Exchange Platform (EURDEP) was created in 19952 to that end - to provide radiation monitoring data from most European countries reported in nearly real-time. During the response operations for the Fukushima Dai-ichi nuclear power plant accident (March 2011) the IAEA Incident and Emergency Centre (IEC) managed, harmonized and shared the large amount of data that was being generated from different organizations. This task underscored the need for a system which allows sharing large volumes of radiation monitoring data in an emergency. In 2014 EURDEP started the submission of the European radiological data to the International Radiation Monitoring Information System (IRMIS) as a European Regional HUB for IRMIS. IRMIS supports the implementation of the Convention on Early Notification of a Nuclear Accident by providing a web application for the reporting, sharing, visualizing and analysing of large quantities of environmental radiation monitoring data during nuclear or radiological emergencies. IRMIS is not an early warning system that automatically reports when there are significant deviations in radiation levels or when values are detected above certain levels. However, the configuration of the visualization features offered by IRMIS may help Member States to determine where elevated gamma dose rate measurements during a radiological or nuclear emergency indicate that actions to protect the public are necessary. The data can be used to assist emergency responders determine where and when to take necessary actions to protect the public. This new web online tool supports the IAEA's Unified System for Information Exchange in Incidents and Emergencies (USIE)3, an online tool where competent authorities can access information about all emergency situations, ranging from a lost radioactive source to a full-scale nuclear emergency.
Exposure studies rely on detailed characterization of air quality, either from sparsely located routine ambient monitors or from central monitoring sites that may lack spatial representativeness. Alternatively, some studies use models of various complexities to characterize local...
NASA Astrophysics Data System (ADS)
De Rosa, Benedetto; Di Girolamo, Paolo; Summa, Donato; Stelitano, Dario; Mancini, Ignazio
2016-06-01
In November 2012 the University of BASILicata Raman Lidar system (BASIL) was approved to enter the International Network for the Detection of Atmospheric Composition Change (NDACC). This network includes more than 70 high-quality, remote-sensing research stations for observing and understanding the physical and chemical state of the upper troposphere and stratosphere and for assessing the impact of stratosphere changes on the underlying troposphere and on global climate. As part of this network, more than thirty groundbased Lidars deployed worldwide are routinely operated to monitor atmospheric ozone, temperature, aerosols, water vapour, and polar stratospheric clouds. In the frame of NDACC, BASIL performs measurements on a routine basis each Thursday, typically from local noon to midnight, covering a large portion of the daily cycle. Measurements from BASIL are included in the NDACC database both in terms of water vapour mixing ratio and temperature. This paper illustrates some measurement examples from BASIL, with a specific focus on water vapour measurements, with the goal to try and characterize the system performances.
Pineles, Lisa L; Morgan, Daniel J; Limper, Heather M; Weber, Stephen G; Thom, Kerri A; Perencevich, Eli N; Harris, Anthony D; Landon, Emily
2014-02-01
Hand hygiene (HH) is a critical part of infection prevention in health care settings. Hospitals around the world continuously struggle to improve health care personnel (HCP) HH compliance. The current gold standard for monitoring compliance is direct observation; however, this method is time-consuming and costly. One emerging area of interest involves automated systems for monitoring HH behavior such as radiofrequency identification (RFID) tracking systems. To assess the accuracy of a commercially available RFID system in detecting HCP HH behavior, we compared direct observation with data collected by the RFID system in a simulated validation setting and to a real-life clinical setting over 2 hospitals. A total of 1,554 HH events was observed. Accuracy for identifying HH events was high in the simulated validation setting (88.5%) but relatively low in the real-life clinical setting (52.4%). This difference was significant (P < .01). Accuracy for detecting HCP movement into and out of patient rooms was also high in the simulated setting but not in the real-life clinical setting (100% on entry and exit in simulated setting vs 54.3% entry and 49.5% exit in real-life clinical setting, P < .01). In this validation study of an RFID system, almost half of the HH events were missed. More research is necessary to further develop these systems and improve accuracy prior to widespread adoption. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Kroening, Sharon E.
2008-01-01
Surface- and ground-water quality data from the Mosquito Lagoon Basin were compiled and analyzed to: (1) describe historical and current monitoring in the basin, (2) summarize surface- and ground-water quality conditions with an emphasis on identifying areas that require additional monitoring, and (3) develop a water-quality monitoring network to meet the goals of Canaveral National Seashore (a National Park) and to fill gaps in current monitoring. Water-quality data were compiled from the U.S. Environmental Protection Agency's STORET system, the U.S. Geological Survey's National Water Information System, or from the agency which collected the data. Most water-quality monitoring focused on assessing conditions in Mosquito Lagoon. Significant spatial and/or seasonal variations in water-quality constituents in the lagoon were quantified for pH values, fecal coliform bacteria counts, and concentrations of dissolved oxygen, total nitrogen, total phosphorus, chlorophyll-a, and total suspended solids. Trace element, pesticide, and ground-water-quality data were more limited. Organochlorine insecticides were the major class of pesticides analyzed. A surface- and ground-water-quality monitoring network was designed for the Mosquito Lagoon Basin which emphasizes: (1) analysis of compounds indicative of human activities, including pesticides and other trace organic compounds present in domestic and industrial waste; (2) greater data collection in the southern part of Mosquito Lagoon where spatial variations in water-quality constituents were quantified; and (3) additional ground-water-quality data collection in the surficial aquifer system and Upper Floridan aquifer. Surface-water-quality data collected as part of this network would include a fixed-station monitoring network of eight sites in the southern part of the basin, including a canal draining Oak Hill. Ground-water quality monitoring should be done routinely at about 20 wells in the surficial aquifer system and Upper Floridan aquifer, distributed between developed and undeveloped parts of the basin. Water samples collected should be analyzed for a wide range of constituents, including physical properties, nutrients, suspended sediment, and constituents associated with increased urban development such as pesticides, other trace organic compounds associated with domestic and industrial waste, and trace elements.
Gunn, Jane M; Palmer, Victoria J; Dowrick, Christopher F; Herrman, Helen E; Griffiths, Frances E; Kokanovic, Renata; Blashki, Grant A; Hegarty, Kelsey L; Johnson, Caroline L; Potiriadis, Maria; May, Carl R
2010-08-06
Depression and related disorders represent a significant part of general practitioners (GPs) daily work. Implementing the evidence about what works for depression care into routine practice presents a challenge for researchers and service designers. The emerging consensus is that the transfer of efficacious interventions into routine practice is strongly linked to how well the interventions are based upon theory and take into account the contextual factors of the setting into which they are to be transferred. We set out to develop a conceptual framework to guide change and the implementation of best practice depression care in the primary care setting. We used a mixed method, observational approach to gather data about routine depression care in a range of primary care settings via: audit of electronic health records; observation of routine clinical care; and structured, facilitated whole of organisation meetings. Audit data were summarised using simple descriptive statistics. Observational data were collected using field notes. Organisational meetings were audio taped and transcribed. All the data sets were grouped, by organisation, and considered as a whole case. Normalisation Process Theory (NPT) was identified as an analytical theory to guide the conceptual framework development. Five privately owned primary care organisations (general practices) and one community health centre took part over the course of 18 months. We successfully developed a conceptual framework for implementing an effective model of depression care based on the four constructs of NPT: coherence, which proposes that depression work requires the conceptualisation of boundaries of who is depressed and who is not depressed and techniques for dealing with diffuseness; cognitive participation, which proposes that depression work requires engagement with a shared set of techniques that deal with depression as a health problem; collective action, which proposes that agreement is reached about how care is organised; and reflexive monitoring, which proposes that depression work requires agreement about how depression work will be monitored at the patient and practice level. We describe how these constructs can be used to guide the design and implementation of effective depression care in a way that can take account of contextual differences. Ideas about what is required for an effective model and system of depression care in primary care need to be accompanied by theoretically informed frameworks that consider how these can be implemented. The conceptual framework we have presented can be used to guide organisational and system change to develop common language around each construct between policy makers, service users, professionals, and researchers. This shared understanding across groups is fundamental to the effective implementation of change in primary care for depression.
W. Sutton; E.M. Hansen; P. Reeser; A. Kanaskie
2008-01-01
Oregon was a participant in the pilot test of the national stream monitoring protocol for SOD. We routinely and continuously monitor about 50 streams in and near the SOD quarantine area in southwest Oregon using foliage baits. For the national protocol, we added six additional streams beyond the area of known infestation, and compared results from different diagnostic...
Research for Developing Renewable Biofuels from Algae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Black, Paul N.
Task A. Expansion of knowledge related to lipid production and secretion in algae A.1 Lipid biosynthesis in target algal species; Systems biology approaches are being used in combination with recent advances in Chlorella and Chlamydomonas genomics to address lipid accumulation in response to defined nutrient regimes. The UNL Algal Group continues screening additional species of Chlorella and other naturally occurring algae for those with optimal triglyceride production; Of the strains examined by the DOE's Aquatic Species Program, green algae, several species of Chlorella represent the largest group from which oleaginous candidates have been identified; A.1.1. Lipid profiling; Neutral lipid accumulationmore » is routinely monitored by Nile red and BODIPY staining using high throughput strategies to screen for naturally occurring algae that accumulate triglyceride. These strategies complement those using spectrofluorometry to quantify lipid accumulation; Neutral lipid accumulation is routinely monitored by high performance thin-layer chromatography (HPTLC) and high performance liquid chromatography (HPLC) of lipid extracts in conjunction with; Carbon portioning experiments have been completed and the data currently are being analyzed and prepared for publication; Methods in the Black lab were developed to identify and quantify triacylglycerol (TAG), major membrane lipids [diacylglycerol trimethylhomoserine, phosphatidylethanolamine and chloroplast glycolipids], biosynthetic intermediates such as diacylglycerol, phosphatidic acid and lysophospholipids and different species of acyl-coenzyme A (acyl CoA).« less
A review of smart homes- present state and future challenges.
Chan, Marie; Estève, Daniel; Escriba, Christophe; Campo, Eric
2008-07-01
In the era of information technology, the elderly and disabled can be monitored with numerous intelligent devices. Sensors can be implanted into their home for continuous mobility assistance and non-obtrusive disease prevention. Modern sensor-embedded houses, or smart houses, cannot only assist people with reduced physical functions but help resolve the social isolation they face. They are capable of providing assistance without limiting or disturbing the resident's daily routine, giving him or her greater comfort, pleasure, and well-being. This article presents an international selection of leading smart home projects, as well as the associated technologies of wearable/implantable monitoring systems and assistive robotics. The latter are often designed as components of the larger smart home environment. The paper will conclude by discussing future challenges of the domain.
Operational skill assessment of the IBI-MFC Ocean Forecasting System within the frame of the CMEMS.
NASA Astrophysics Data System (ADS)
Lorente Jimenez, Pablo; Garcia-Sotillo, Marcos; Amo-Balandron, Arancha; Aznar Lecocq, Roland; Perez Gomez, Begoña; Levier, Bruno; Alvarez-Fanjul, Enrique
2016-04-01
Since operational ocean forecasting systems (OOFSs) are increasingly used as tools to support high-stakes decision-making for coastal management, a rigorous skill assessment of model performance becomes essential. In this context, the IBI-MFC (Iberia-Biscay-Ireland Monitoring & Forecasting Centre) has been providing daily ocean model estimates and forecasts for the IBI regional seas since 2011, first in the frame of MyOcean projects and later as part of the Copernicus Marine Environment Monitoring Service (CMEMS). A comprehensive web validation tool named NARVAL (North Atlantic Regional VALidation) has been developed to routinely monitor IBI performance and to evaluate model's veracity and prognostic capabilities. Three-dimensional comparisons are carried out on a different time basis ('online mode' - daily verifications - and 'delayed mode' - for longer time periods -) using a broad variety of in-situ (buoys, tide-gauges, ARGO-floats, drifters and gliders) and remote-sensing (satellite and HF radars) observational sources as reference fields to validate against the NEMO model solution. Product quality indicators and meaningful skill metrics are automatically computed not only averaged over the entire IBI domain but also over specific sub-regions of particular interest from a user perspective (i.e. coastal or shelf areas) in order to determine IBI spatial and temporal uncertainty levels. A complementary aspect of NARVAL web tool is the intercomparison of different CMEMS forecast model solutions in overlapping areas. Noticeable efforts are in progress in order to quantitatively assess the quality and consistency of nested system outputs by setting up specific intercomparison exercises on different temporal and spatial scales, encompassing global configurations (CMEMS Global system), regional applications (NWS and MED ones) and local high-resolution coastal models (i.e. the PdE SAMPA system in the Gibraltar Strait). NARVAL constitutes a powerful approach to increase our knowledge on the IBI-MFC forecast system and aids us to inform CMEMS end users about the provided ocean forecasting products' confidence level by routinely delivering QUality Information Documents (QUIDs). It allows the detection of strengths and weaknesses in the modeling of several key physical processes and the understanding of potential sources of discrepancies in IBI predictions. Once the numerical model shortcomings are identified, potential improvements can be achieved thanks to reliable upgrades, making evolve IBI OOFS towards more refined and advanced versions.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-20
..., organization, or individual for the purpose of performing audit or oversight operations related to this system...; System of Records; Statement of General Routine Uses; Notice of Establishment of Three New General... systems of records. Comment is invited on the three new routine uses. The three new routine uses are...
Sifuna, Peter; Oyugi, Mary; Ogutu, Bernhards; Andagalu, Ben; Otieno, Allan; Owira, Victorine; Otsyula, Nekoye; Oyieko, Janet; Cowden, Jessica; Otieno, Lucas; Otieno, Walter
2014-08-01
The Kombewa Health and Demographic Surveillance System (HDSS) grew out of the Kombewa Clinical Research Centre in 2007 and has since established itself as a platform for the conduct of regulated clinical trials, nested studies and local disease surveillance. The HDSS is located in a rural part of Kisumu County, Western Kenya, and covers an area of about 369 km(2) along the north-eastern shores of Lake Victoria. A dynamic cohort of 141 956 individuals drawn from 34 718 households forms the HDSS surveillance population. Following a baseline survey in 2011, the HDSS continues to monitor key population changes through routine biannual household surveys. The intervening period between set-up and baseline census was used for preparatory work, in particular Global Positioning System (GPS) mapping. Routine surveys capture information on individual and households including residency, household relationships, births, deaths, migrations (in and out) and causes of morbidity (syndromic incidence and prevalence) as well as causes of death (verbal autopsy). The Kombewa HDSS platform is used to support health research activities, that is clinical trials and epidemiological studies evaluating diseases of public health importance including malaria, HIV and global emerging infectious diseases such as dengue fever. © The Author 2014; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.
Vidal, J; Muinelo, L; Dalmases, A; Jones, F; Edelstein, D; Iglesias, M; Orrillo, M; Abalo, A; Rodríguez, C; Brozos, E; Vidal, Y; Candamio, S; Vázquez, F; Ruiz, J; Guix, M; Visa, L; Sikri, V; Albanell, J; Bellosillo, B; López, R; Montagut, C
2017-01-01
Abstract Background RAS assessment is mandatory for therapy decision in metastatic colorectal cancer (mCRC) patients. This determination is based on tumor tissue, however, genotyping of circulating tumor (ct)DNA offers clear advantages as a minimally invasive method that represents tumor heterogeneity. Our study aims to evaluate the use of ctDNA as an alternative for determining baseline RAS status and subsequent monitoring of RAS mutations during therapy as a component of routine clinical practice. Patients and methods RAS mutational status in plasma was evaluated in mCRC patients by OncoBEAM™ RAS CRC assay. Concordance of results in plasma and tissue was retrospectively evaluated. RAS mutations were also prospectively monitored in longitudinal plasma samples from selected patients. Results Analysis of RAS in tissue and plasma samples from 115 mCRC patients showed a 93% overall agreement. Plasma/tissue RAS discrepancies were mainly explained by spatial and temporal tumor heterogeneity. Analysis of clinico-pathological features showed that the site of metastasis (i.e. peritoneal, lung), the histology of the tumor (i.e. mucinous) and administration of treatment previous to blood collection negatively impacted the detection of RAS in ctDNA. In patients with baseline mutant RAS tumors treated with chemotherapy/antiangiogenic, longitudinal analysis of RAS ctDNA mirrored response to treatment, being an early predictor of response. In patients RAS wt, longitudinal monitoring of RAS ctDNA revealed that OncoBEAM was useful to detect emergence of RAS mutations during anti-EGFR treatment. Conclusion The high overall agreement in RAS mutational assessment between plasma and tissue supports blood-based testing with OncoBEAM™ as a viable alternative for genotyping RAS of mCRC patients in routine clinical practice. Our study describes practical clinico-pathological specifications to optimize RAS ctDNA determination. Moreover, OncoBEAM™ is useful to monitor RAS in patients undergoing systemic therapy to detect resistance and evaluate the efficacy of particular treatments. PMID:28419195
Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S
2015-01-01
A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the 'EmOC signal functions', a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants' adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining MNH program evaluations in LMICs.
Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S.
2015-01-01
Background A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the ‘EmOC signal functions’, a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. Methods We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Results Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants’ adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. Conclusion The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining MNH program evaluations in LMICs. PMID:25875252
Discovering Activities to Recognize and Track in a Smart Environment.
Rashidi, Parisa; Cook, Diane J; Holder, Lawrence B; Schmitter-Edgecombe, Maureen
2011-01-01
The machine learning and pervasive sensing technologies found in smart homes offer unprecedented opportunities for providing health monitoring and assistance to individuals experiencing difficulties living independently at home. In order to monitor the functional health of smart home residents, we need to design technologies that recognize and track activities that people normally perform as part of their daily routines. Although approaches do exist for recognizing activities, the approaches are applied to activities that have been pre-selected and for which labeled training data is available. In contrast, we introduce an automated approach to activity tracking that identifies frequent activities that naturally occur in an individual's routine. With this capability we can then track the occurrence of regular activities to monitor functional health and to detect changes in an individual's patterns and lifestyle. In this paper we describe our activity mining and tracking approach and validate our algorithms on data collected in physical smart environments.
Anesthesia Quality and Patient Safety in China: A Survey.
Zhu, Bin; Gao, Huan; Zhou, Xiangyong; Huang, Jeffrey
There has been no nationwide investigation into anesthesia quality and patient safety in China. The authors surveyed Chinese anesthesiologists about anesthesia quality by sending a survey to all anesthesiologist members of the New Youth Anesthesia Forum via WeChat. The respondents could choose to use a mobile device or desktop to complete the survey. The overall response rate was 43%. Intraoperative monitoring: 77.9% of respondents reported that electrocardiogram monitoring was routinely applied for all patients; only 55% of the respondents reported that they routinely used end-tidal carbon dioxide monitoring for their patients under general anesthesia. 10.3% of respondents admitted that they had at least one wrong medicine administration in the past 3 months; 12.4% reported that they had at least one case of cardiac arrest in the past year. This is the first anesthesia quality survey in China. The findings revealed potential anesthesia safety issues in China.
Using lithium ion batteries in the aeromedical environment: a calculated risk?
Haggerty, Andrew; Keogh, Sean
2015-04-01
Lithium ion batteries are increasingly utilised within helicopter emergency medical services. Their favourable chemical profile confers many desirable properties: they are small, lightweight and provide a high specific capacity (energy to weight ratio) coupled with a slow self-discharge rate, ensuring a longer functional availability for vital equipment. They are frequently used in routine medical equipment including ventilators, monitors and intravenous pumps, and in aviation specific items, such as satellite and mobile phones, VHF radios and navigation systems. © 2015 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
NASA Technical Reports Server (NTRS)
Stocker, Erich Franz
2004-01-01
TRMM has been an imminently successful mission from an engineering standpoint but even more from a science standpoint. An important part of this science success has been the careful quality control of the TRMM standard products. This paper will present the quality monitoring efforts that the TRMM Science Data and Information System (TSDIS) conducts on a routine basis. The paper will detail parameter trending, geolocation quality control and the procedures to support the preparation of next versions of the algorithm used for reprocessing.
Unsupervised daily routine and activity discovery in smart homes.
Jie Yin; Qing Zhang; Karunanithi, Mohan
2015-08-01
The ability to accurately recognize daily activities of residents is a core premise of smart homes to assist with remote health monitoring. Most of the existing methods rely on a supervised model trained from a preselected and manually labeled set of activities, which are often time-consuming and costly to obtain in practice. In contrast, this paper presents an unsupervised method for discovering daily routines and activities for smart home residents. Our proposed method first uses a Markov chain to model a resident's locomotion patterns at different times of day and discover clusters of daily routines at the macro level. For each routine cluster, it then drills down to further discover room-level activities at the micro level. The automatic identification of daily routines and activities is useful for understanding indicators of functional decline of elderly people and suggesting timely interventions.
Expansion of Viral Load Testing and the Potential Impact on HIV Drug Resistance.
Raizes, Elliot; Hader, Shannon; Birx, Deborah
2017-12-01
The US President's Emergency Plan for AIDS Relief (PEPFAR) supports aggressive scale-up of antiretroviral therapy (ART) in high-burden countries and across all genders and populations at risk toward global human immunodeficiency virus (HIV) epidemic control. PEPFAR recognizes the risk of HIV drug resistance (HIVDR) as a consequence of aggressive ART scale-up and is actively promoting 3 key steps to mitigate the impact of HIVDR: (1) routine access to routine viral load monitoring in all settings; (2) optimization of ART regimens; and (3) routine collection and analysis of HIVDR data to monitor the success of mitigation strategies. The transition to dolutegravir-based regimens in PEPFAR-supported countries and the continuous evolution of HIVDR surveillance strategies are essential elements of PEPFAR implementation. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Groundwater Remediation and Alternate Energy at White Sands Test Facility
NASA Technical Reports Server (NTRS)
Fischer, Holger
2008-01-01
White Sands Test Facility Core Capabilities: a) Remote Hazardous Testing of Reactive, Explosive, and Toxic Materials and Fluids; b) Hypergolic Fluids Materials and Systems Testing; c) Oxygen Materials and System Testing; d) Hypervelocity Impact Testing; e)Flight Hardware Processing; and e) Propulsion Testing. There is no impact to any drinking water well. Includes public wells and the NASA supply well. There is no public exposure. Groundwater is several hundred feet below ground. No air or surface water exposure. Plume is moving very slowly to the west. Plume Front Treatment system will stop this westward movement. NASA performs on-going monitoring. More than 200 wells and zones are routinely sampled. Approx. 850 samples are obtained monthly and analyzed for over 300 different hazardous chemicals.
NASA Technical Reports Server (NTRS)
Johnston, William; Tierney, Brian; Lee, Jason; Hoo, Gary; Thompson, Mary
1996-01-01
We have developed and deployed a distributed-parallel storage system (DPSS) in several high speed asynchronous transfer mode (ATM) wide area networks (WAN) testbeds to support several different types of data-intensive applications. Architecturally, the DPSS is a network striped disk array, but is fairly unique in that its implementation allows applications complete freedom to determine optimal data layout, replication and/or coding redundancy strategy, security policy, and dynamic reconfiguration. In conjunction with the DPSS, we have developed a 'top-to-bottom, end-to-end' performance monitoring and analysis methodology that has allowed us to characterize all aspects of the DPSS operating in high speed ATM networks. In particular, we have run a variety of performance monitoring experiments involving the DPSS in the MAGIC testbed, which is a large scale, high speed, ATM network and we describe our experience using the monitoring methodology to identify and correct problems that limit the performance of high speed distributed applications. Finally, the DPSS is part of an overall architecture for using high speed, WAN's for enabling the routine, location independent use of large data-objects. Since this is part of the motivation for a distributed storage system, we describe this architecture.
Engelsman, A F; Warhurst, S; Fraser, S; Novakovic, D; Sidhu, S B
2018-06-01
Integrity of the recurrent laryngeal nerve (RLN) and the external branch of the superior laryngeal nerve (EBSLN) can be checked by intraoperative nerve monitoring (IONM) after visualization. The aim of this study was to determine the prevalence and nature of voice dysfunction following thyroid surgery with routine IONM. Thyroidectomies were performed with routine division of strap muscles and nerve monitoring to confirm integrity of the RLN and EBSLN following dissection. Patients were assessed for vocal function before surgery and at 1 and 3 months after operation. Assessment included use of the Voice Handicap Index (VHI) 10, maximum phonation time, fundamental frequency, pitch range, harmonic to noise ratio, cepstral peak prominence and smoothed cepstral peak prominence. A total of 172 nerves at risk were analysed in 102 consecutive patients undergoing elective thyroid surgery. In 23·3 per cent of EBSLNs and 0·6 per cent of RLNs nerve identification required the assistance of IONM in addition to visualization. Nerve integrity was confirmed during surgery for 98·8 per cent of EBSLNs and 98·3 per cent of RLNs. There were no differences between preoperative and postoperative VHI-10 scores. Acoustic voice assessment showed small changes in maximum phonation time at 1 and 3 months after surgery. Where there is routine division of strap muscles, thyroidectomy using nerve monitoring confirmation of RLN and EBSLN function following dissection results in no clinically significant voice change.
NASA Technical Reports Server (NTRS)
Crucian, Brian; Stowe, Raymond; Mehta, Satish; Uchakin, Peter; Nehlsen-Cannarella, Sandra; Morukov, Boris; Pierson, Duane; Sams, Clarence
2007-01-01
There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk from prolonged immune dysregulation during space flight are not yet determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight condition. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flight-compatible immune monitoring strategy. Characterization of the clinical risk and the development of a monitoring strategy are necessary prerequisite activities prior to validating countermeasures. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers immune system. Pre-flight, in-flight and post-flight assessments of immune status, immune function, viral reactivation and physiological stress will be performed. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter landing day assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. Following completion of the SMO the data will be evaluated to determine the optimal set of assays for routine monitoring of crewmember immune system function, should the clinical risk warrant such monitoring.
Hains, I M; Ward, R L; Pearson, S-A
2012-01-01
EviQ is a web-based oncology protocol system launched across Australia in 2005 (http://www.eviq.org.au). We evaluated eviQ use at the point-of-care and determined the factors impacting on its uptake and routine use in the first three years of operation. We conducted a suite of qualitative and quantitative studies with over 200 Australian oncology physicians, nurses and pharmacists working at treatment centres in diverse geographical locations. EviQ was part of routine care at many hospitals; however, the way in which it was used at the point-of-care varies according to clinician roles and hospital location. We identified a range of factors impacting on eviQ uptake and routine use. Infrastructure, such as availability of point-of-care computers, and formal policies endorsing eviQ are fundamental to increasing uptake. Furthermore, the level of clinical and computer experience of end-users, the attitudes and behaviour of clinicians, endorsement and promotion strategies, and level and type of eviQ education all need to be considered and managed to ensure that the system is being used to its full potential. Our findings show that the dissemination of web-based treatment protocols does not guarantee widespread use. Organisational, environmental and clinician-specific factors play a role in uptake and utilisation. The deployment of sufficient computer infrastructure, implementation of targeted training programmes and hospital policies and investment in marketing approaches are fundamental to uptake and continued use. This study highlights the value of ongoing monitoring and evaluation to ensure systems like eviQ achieve their primary purpose - reducing treatment variation and improving quality of care. © 2010 The Authors. Internal Medicine Journal © 2010 Royal Australasian College of Physicians.
PROMIS (Procurement Management Information System)
NASA Technical Reports Server (NTRS)
1987-01-01
The PROcurement Management Information System (PROMIS) provides both detailed and summary level information on all procurement actions performed within NASA's procurement offices at Marshall Space Flight Center (MSFC). It provides not only on-line access, but also schedules procurement actions, monitors their progress, and updates Forecast Award Dates. Except for a few computational routines coded in FORTRAN, the majority of the systems is coded in a high level language called NATURAL. A relational Data Base Management System called ADABAS is utilized. Certain fields, called descriptors, are set up on each file to allow the selection of records based on a specified value or range of values. The use of like descriptors on different files serves as the link between the falls, thus producing a relational data base. Twenty related files are currently being maintained on PROMIS.
Step 6: Does Not Routinely Employ Practices, Procedures Unsupported by Scientific Evidence
Goer, Henci; Sagady Leslie, Mayri; Romano, Amy
2007-01-01
Step 6 of the Ten Steps of Mother-Friendly Care addresses two issues: 1) the routine use of interventions (shaving, enemas, intravenous drips, withholding food and fluids, early rupture of membranes, and continuous electronic fetal monitoring; and 2) the optimal rates of induction, episiotomy, cesareans, and vaginal births after cesarean. Rationales for compliance and systematic reviews are presented. PMID:18523680
High resolution remote sensing of densely urbanised regions: a case study of Hong Kong.
Nichol, Janet E; Wong, Man Sing
2009-01-01
Data on the urban environment such as climate or air quality is usually collected at a few point monitoring stations distributed over a city. However, the synoptic viewpoint of satellites where a whole city is visible on a single image permits the collection of spatially comprehensive data at city-wide scale. In spite of rapid developments in remote sensing systems, deficiencies in image resolution and algorithm development still exist for applications such as air quality monitoring and urban heat island analysis. This paper describes state-of-the-art techniques for enhancing and maximising the spatial detail available from satellite images, and demonstrates their applications to the densely urbanised environment of Hong Kong. An Emissivity Modulation technique for spatial enhancement of thermal satellite images permits modelling of urban microclimate in combination with other urban structural parameters at local scale. For air quality monitoring, a Minimum Reflectance Technique (MRT) has been developed for MODIS 500 m images. The techniques described can promote the routine utilization of remotely sensed images for environmental monitoring in cities of the 21(st) century.
Hydrogel-based electrochemical sensor for non-invasive and continuous glucose monitoring
NASA Astrophysics Data System (ADS)
Park, Habeen; Lee, Ji-Young; Kim, Dong-Chul; Koh, Younggook; Cha, Junhoe
2017-07-01
Monitoring blood glucose level of diabetic patients is crucial in diabetes care from life threating complications. Selfmonitoring blood glucose (SMBG) that involves finger prick to draw blood samples into the measurement system is a widely-used method of routine measurement of blood glucose levels to date. SMBG includes, however, unavoidable pain problems resulting from the repetitive measurements. We hereby present a hydrogel-based electrochemical (H-EC) sensor to monitor the glucose level, non-invasively. Glucose oxidase (GOx) was immobilized in the disc-type hydroxyethyl methacrylate (HEMA) based hydrogel and kept intact in the hydrogel. Fast electron transfer mediated by Prussian blue (PB, hexacyanoferrate) generated efficient signal amplifications to facilitate the detection of the extracted glucose from the interstitial fluid. The linear response and the selectivity against glucose of the H-EC sensor were validated by chronoamperometry. For the practical use, the outcomes from the correlation of the extracted glucose concentration and the blood glucose value by on-body extraction, as well as the validation of the hydrogel-based electrochemical (H-EC) device, were applied to the on-body glucose monitoring.
High Resolution Remote Sensing of Densely Urbanised Regions: a Case Study of Hong Kong
Nichol, Janet E.; Wong, Man Sing
2009-01-01
Data on the urban environment such as climate or air quality is usually collected at a few point monitoring stations distributed over a city. However, the synoptic viewpoint of satellites where a whole city is visible on a single image permits the collection of spatially comprehensive data at city-wide scale. In spite of rapid developments in remote sensing systems, deficiencies in image resolution and algorithm development still exist for applications such as air quality monitoring and urban heat island analysis. This paper describes state-of-the-art techniques for enhancing and maximising the spatial detail available from satellite images, and demonstrates their applications to the densely urbanised environment of Hong Kong. An Emissivity Modulation technique for spatial enhancement of thermal satellite images permits modelling of urban microclimate in combination with other urban structural parameters at local scale. For air quality monitoring, a Minimum Reflectance Technique (MRT) has been developed for MODIS 500 m images. The techniques described can promote the routine utilization of remotely sensed images for environmental monitoring in cities of the 21st century. PMID:22408549
Application of the automated spatial surveillance program to birth defects surveillance data.
Gardner, Bennett R; Strickland, Matthew J; Correa, Adolfo
2007-07-01
Although many birth defects surveillance programs incorporate georeferenced records into their databases, practical methods for routine spatial surveillance are lacking. We present a macroprogram written for the software package R designed for routine exploratory spatial analysis of birth defects data, the Automated Spatial Surveillance Program (ASSP), and present an application of this program using spina bifida prevalence data for metropolitan Atlanta. Birth defects surveillance data were collected by the Metropolitan Atlanta Congenital Defects Program. We generated ASSP maps for two groups of years that correspond roughly to the periods before (1994-1998) and after (1999-2002) folic acid fortification of flour. ASSP maps display census tract-specific spina bifida prevalence, smoothed prevalence contours, and locations of statistically elevated prevalence. We used these maps to identify areas of elevated prevalence for spina bifida. We identified a large area of potential concern in the years following fortification of grains and cereals with folic acid. This area overlapped census tracts containing large numbers of Hispanic residents. The potential utility of ASSP for spatial disease monitoring was demonstrated by the identification of areas of high prevalence of spina bifida and may warrant further study and monitoring. We intend to further develop ASSP so that it becomes practical for routine spatial monitoring of birth defects. (c) 2007 Wiley-Liss, Inc.
Sala-Comorera, Laura; Vilaró, Carles; Galofré, Belén; Blanch, Anicet R; García-Aljaro, Cristina
2016-10-01
The study of bacterial communities throughout a drinking water treatment plant could provide a basic understanding of the effects of water processing that could then be used to improve the management of such plants. However, it is necessary to develop new analytical techniques that are sufficiently efficient, robust and fast for their effective and useful application in routine analysis. The aim of this study is therefore to assess the performance of matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS), as compared to the PhenePlate™ system, for routine analysis in a drinking water treatment plant. To this end we studied a total of 277 colonies isolated in different seasons and from different points throughout the water treatment process, including: raw water, sand filtration, ultrafiltration, reverse osmosis and chlorination. The colonies were analysed using MALDI-TOF MS by direct deposition of the cells on the plate. The colonies were also biochemically fingerprinted using the PhenePlate™ system, clustered according to their similarity and a representative strain was selected for 16S rRNA gene sequencing and API ® gallery-based identification. The use of MALDI-TOF MS was reliable compared to the PhenePlate™ system and has the advantage of being faster and relatively cheap. Bacteria typing by MALDI-TOF MS is therefore a promising method to replace conventional routine phenotypic methods for the identification of bacteria in drinking water laboratories, thanks to its robustness. The major limiting factor for MALDI-TOF MS is the lack of a suitable mass spectra database; although each laboratory can develop its own library. This methodology will provide a tracking tool for companies to use in risk management and the detection of possible failures in both the water treatment processes and the distribution network, as well as offering characterization of the intrinsic microbial populations. Copyright © 2016 Elsevier GmbH. All rights reserved.
Tasma, M; Liemburg, E J; Knegtering, H; Delespaul, P A E G; Boonstra, A; Castelein, S
2017-05-01
Routine Outcome Monitoring (ROM) has become part of the treatment process in mental health care. However, studies have indicated that few clinicians in psychiatry use the outcome of ROM in their daily work. The aim of this study was to explore the degree of ROM use in clinical practice as well as the explanatory factors of this use. In the Northern Netherlands, a ROM-protocol (ROM-Phamous) for patients with a psychotic disorder has been implemented. To establish the degree of ROM-Phamous use in clinical practice, the ROM results of patients (n=204) were compared to the treatment goals formulated in their treatment plans. To investigate factors that might influence ROM use, clinicians (n=32) were asked to fill out a questionnaire about ROM-Phamous. Care domains that were problematic according to the ROM-Phamous results were mentioned in the treatment plan in 28% of cases on average (range 5-45%). The use of ROM-Phamous in the treatment process varies considerably among clinicians. Most of the clinicians find ROM-Phamous both useful and important for good clinical practice. In contrast, the perceived ease-of-use is low and most clinicians report insufficient time to use ROM-Phamous. More frequent ROM use should be facilitated in clinicians. This could be achieved by improving the fit with clinical routines and the ease-of-use of ROM systems. It is important for all stakeholders to invest in integrating ROM in clinical practice. Eventually, this might improve the diagnostics and treatment of patients in mental health care. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
CPU timing routines for a CONVEX C220 computer system
NASA Technical Reports Server (NTRS)
Bynum, Mary Ann
1989-01-01
The timing routines available on the CONVEX C220 computer system in the Structural Mechanics Division (SMD) at NASA Langley Research Center are examined. The function of the timing routines, the use of the timing routines in sequential, parallel, and vector code, and the interpretation of the results from the timing routines with respect to the CONVEX model of computing are described. The timing routines available on the SMD CONVEX fall into two groups. The first group includes standard timing routines generally available with UNIX 4.3 BSD operating systems, while the second group includes routines unique to the SMD CONVEX. The standard timing routines described in this report are /bin/csh time,/bin/time, etime, and ctime. The routines unique to the SMD CONVEX are getinfo, second, cputime, toc, and a parallel profiling package made up of palprof, palinit, and palsum.
Cao, Mingyan; Mo, Wenjun David; Shannon, Anthony; Wei, Ziping; Washabaugh, Michael; Cash, Patricia
Aspartate (Asp) isomerization is a common post-translational modification of recombinant therapeutic proteins that can occur during manufacturing, storage, or administration. Asp isomerization in the complementarity-determining regions of a monoclonal antibody may affect the target binding and thus a sufficiently robust quality control method for routine monitoring is desirable. In this work, we utilized a liquid chromatography-mass spectrometry (LC/MS)-based approach to identify the Asp isomerization in the complementarity-determining regions of a therapeutic monoclonal antibody. To quantitate the site-specific Asp isomerization of the monoclonal antibody, a UV detection-based quantitation assay utilizing the same LC platform was developed. The assay was qualified and implemented for routine monitoring of this product-specific modification. Compared with existing methods, this analytical paradigm is applicable to identify Asp isomerization (or other modifications) and subsequently develop a rapid, sufficiently robust quality control method for routine site-specific monitoring and quantitation to ensure product quality. This approach first identifies and locates a product-related impurity (a critical quality attribute) caused by isomerization, deamidation, oxidation, or other post-translational modifications, and then utilizes synthetic peptides and MS to assist the development of a LC-UV-based chromatographic method that separates and quantifies the product-related impurities by UV peaks. The established LC-UV method has acceptable peak specificity, precision, linearity, and accuracy; it can be validated and used in a good manufacturing practice environment for lot release and stability testing. Aspartate isomerization is a common post-translational modification of recombinant proteins during manufacture process and storage. Isomerization in the complementarity-determining regions (CDRs) of a monoclonal antibody A (mAb-A) has been detected and has been shown to have impact on the binding affinity to the antigen. In this work, we utilized a mass spectrometry-based peptide mapping approach to detect and quantitate the Asp isomerization in the CDRs of mAb-A. To routinely monitor the CDR isomerization of mAb-A, a focused peptide mapping method utilizing reversed phase chromatographic separation and UV detection has been developed and qualified. This approach is generally applicable to monitor isomerization and other post-translational modifications of proteins in a specific and high-throughput mode to ensure product quality. © PDA, Inc. 2016.
Mutale, Wilbroad; Chintu, Namwinga; Amoroso, Cheryl; Awoonor-Williams, Koku; Phillips, James; Baynes, Colin; Michel, Cathy; Taylor, Angela; Sherr, Kenneth
2013-01-01
Weak health information systems (HIS) are a critical challenge to reaching the health-related Millennium Development Goals because health systems performance cannot be adequately assessed or monitored where HIS data are incomplete, inaccurate, or untimely. The Population Health Implementation and Training (PHIT) Partnerships were established in five sub-Saharan African countries (Ghana, Mozambique, Rwanda, Tanzania, and Zambia) to catalyze advances in strengthening district health systems. Interventions were tailored to the setting in which activities were planned. All five PHIT Partnerships share a common feature in their goal of enhancing HIS and linking data with improved decision-making, specific strategies varied. Mozambique, Ghana, and Tanzania all focus on improving the quality and use of the existing Ministry of Health HIS, while the Zambia and Rwanda partnerships have introduced new information and communication technology systems or tools. All partnerships have adopted a flexible, iterative approach in designing and refining the development of new tools and approaches for HIS enhancement (such as routine data quality audits and automated troubleshooting), as well as improving decision making through timely feedback on health system performance (such as through summary data dashboards or routine data review meetings). The most striking differences between partnership approaches can be found in the level of emphasis of data collection (patient versus health facility), and consequently the level of decision making enhancement (community, facility, district, or provincial leadership). Design differences across PHIT Partnerships reflect differing theories of change, particularly regarding what information is needed, who will use the information to affect change, and how this change is expected to manifest. The iterative process of data use to monitor and assess the health system has been heavily communication dependent, with challenges due to poor feedback loops. Implementation to date has highlighted the importance of engaging frontline staff and managers in improving data collection and its use for informing system improvement. Through rigorous process and impact evaluation, the experience of the PHIT teams hope to contribute to the evidence base in the areas of HIS strengthening, linking HIS with decision making, and its impact on measures of health system outputs and impact.
2013-01-01
Background Weak health information systems (HIS) are a critical challenge to reaching the health-related Millennium Development Goals because health systems performance cannot be adequately assessed or monitored where HIS data are incomplete, inaccurate, or untimely. The Population Health Implementation and Training (PHIT) Partnerships were established in five sub-Saharan African countries (Ghana, Mozambique, Rwanda, Tanzania, and Zambia) to catalyze advances in strengthening district health systems. Interventions were tailored to the setting in which activities were planned. Comparisons across strategies All five PHIT Partnerships share a common feature in their goal of enhancing HIS and linking data with improved decision-making, specific strategies varied. Mozambique, Ghana, and Tanzania all focus on improving the quality and use of the existing Ministry of Health HIS, while the Zambia and Rwanda partnerships have introduced new information and communication technology systems or tools. All partnerships have adopted a flexible, iterative approach in designing and refining the development of new tools and approaches for HIS enhancement (such as routine data quality audits and automated troubleshooting), as well as improving decision making through timely feedback on health system performance (such as through summary data dashboards or routine data review meetings). The most striking differences between partnership approaches can be found in the level of emphasis of data collection (patient versus health facility), and consequently the level of decision making enhancement (community, facility, district, or provincial leadership). Discussion Design differences across PHIT Partnerships reflect differing theories of change, particularly regarding what information is needed, who will use the information to affect change, and how this change is expected to manifest. The iterative process of data use to monitor and assess the health system has been heavily communication dependent, with challenges due to poor feedback loops. Implementation to date has highlighted the importance of engaging frontline staff and managers in improving data collection and its use for informing system improvement. Through rigorous process and impact evaluation, the experience of the PHIT teams hope to contribute to the evidence base in the areas of HIS strengthening, linking HIS with decision making, and its impact on measures of health system outputs and impact. PMID:23819699
Smart wearable body sensors for patient self-assessment and monitoring.
Appelboom, Geoff; Camacho, Elvis; Abraham, Mickey E; Bruce, Samuel S; Dumont, Emmanuel Lp; Zacharia, Brad E; D'Amico, Randy; Slomian, Justin; Reginster, Jean Yves; Bruyère, Olivier; Connolly, E Sander
2014-01-01
Innovations in mobile and electronic healthcare are revolutionizing the involvement of both doctors and patients in the modern healthcare system by extending the capabilities of physiological monitoring devices. Despite significant progress within the monitoring device industry, the widespread integration of this technology into medical practice remains limited. The purpose of this review is to summarize the developments and clinical utility of smart wearable body sensors. We reviewed the literature for connected device, sensor, trackers, telemonitoring, wireless technology and real time home tracking devices and their application for clinicians. Smart wearable sensors are effective and reliable for preventative methods in many different facets of medicine such as, cardiopulmonary, vascular, endocrine, neurological function and rehabilitation medicine. These sensors have also been shown to be accurate and useful for perioperative monitoring and rehabilitation medicine. Although these devices have been shown to be accurate and have clinical utility, they continue to be underutilized in the healthcare industry. Incorporating smart wearable sensors into routine care of patients could augment physician-patient relationships, increase the autonomy and involvement of patients in regards to their healthcare and will provide for novel remote monitoring techniques which will revolutionize healthcare management and spending.
Geospace monitoring for space weather research and operation
NASA Astrophysics Data System (ADS)
Nagatsuma, Tsutomu
2017-10-01
Geospace, a space surrounding the Earth, is one of the key area for space weather. Because geospace environment dynamically varies depending on the solar wind conditions. Many kinds of space assets are operating in geospace for practical purposes. Anomalies of space assets are sometimes happened because of space weather disturbances in geospace. Therefore, monitoring and forecasting of geospace environment is very important tasks for NICT's space weather research and development. To monitor and to improve forecasting model, fluxgate magnetometers and HF radars are operated by our laboratory, and its data are used for our research work, too. We also operate real-time data acquisition system for satellite data, such as DSCOVR, STEREO, and routinely received high energy particle data from Himawari-8. Based on these data, we are monitoring current condition of geomagnetic disturbances, and that of radiation belt. Using these data, we have developed empirical models for relativistic electron flux at GEO and inner magnetosphere. To provide userfriendly information , we are trying to develop individual spacecraft anomaly risk estimation tool based on combining models of space weather and those of spacecraft charging, Current status of geospace monitoring, forecasting, and research activities are introduced.
Nevin, N C; McDonald, J R; Walby, A L
1978-12-01
The efficiency of two systems for recording congenital malformations has been compared; one system, the Registrar General's Congenital Malformation Notification, is based on registering all malformed infants, and the other, the Child Health System, records all births. In Northern Ireland for three years [1974--1976], using multiple sources of ascertainment, a total of 686 infants with neural tube defects was identified among 79 783 live and stillbirths. The incidence for all neural tube defects in 8 60 per 1 000 births. The Registrar General's Congenital Malformation Notification System identified 83.6% whereas the Child Health System identified only 63.3% of all neural tube defects. Both systems together identified 86.2% of all neural tube defects. The two systems are suitable for monitoring of malformations and the addition of information from the Genetic Counselling Clinics would enhance the data for epidemiological studies.
Talekar, C R; Udy, A A; Boots, R J; Lipman, J; Cook, D
2014-11-01
The application of tracheal cuff pressure monitoring is likely to vary between institutions. The aim of this study was therefore to review current evidence concerning this intervention in the intensive care unit (ICU) and to appraise regional practice by performing a state-wide survey. Publications for review were identified through searches of PubMed, EMBASE and Cochrane (1977 to 2014). All studies in English relevant to critical care and with complete data were included. Survey questions were developed by small-group consensus. Public and private ICUs across Queensland were contacted, with responses obtained from a representative member of the medical or nursing staff. Existing literature suggests significant variability in tracheal cuff pressure monitoring in the ICU, particularly in the applied technique, frequency of assessment and optimal intra-cuff pressures. Twenty-nine respondents completed the survey, representing 80.5% (29/36) of ICUs in Queensland. Twenty-eight out of twenty-nine respondents reported routinely monitoring tracheal cuff function, primarily employing cuff pressure measurement (26/28). Target cuff pressures varied, with 3/26 respondents aiming for 10 to 20 cmH2O, 10/26 for 21 to 25 cmH2O, and 13/26 for 26 to 30 cmH2O. Fifteen out of twenty-nine reported they had no current guideline or protocol for tracheal cuff management and only 16/29 indicated there was a dedicated area in the clinical record for reporting cuff intervention. Our results indicate that many ICUs across Queensland routinely measure tracheal cuff function, with most utilising pressure monitoring devices. Consistent with existing literature, the optimum cuff pressure remains uncertain. Most, however, considered that this should be a routine part of ICU care.
Pagel, Christina; Utley, Martin; Crowe, Sonya; Witter, Thomas; Anderson, David; Samson, Ray; McLean, Andrew; Banks, Victoria; Tsang, Victor; Brown, Katherine
2013-01-01
Objective To implement routine in-house monitoring of risk-adjusted 30-day mortality following paediatric cardiac surgery. Design Collaborative monitoring software development and implementation in three specialist centres. Patients and methods Analyses incorporated 2 years of data routinely audited by the National Institute of Cardiac Outcomes Research (NICOR). Exclusion criteria were patients over 16 or undergoing non-cardiac or only catheter procedures. We applied the partial risk adjustment in surgery (PRAiS) risk model for death within 30 days following surgery and generated variable life-adjusted display (VLAD) charts for each centre. These were shared with each clinical team and feedback was sought. Results Participating centres were Great Ormond Street Hospital, Evelina Children's Hospital and The Royal Hospital for Sick Children in Glasgow. Data captured all procedures performed between 1 January 2010 and 31 December 2011. This incorporated 2490 30-day episodes of care, 66 of which were associated with a death within 30 days.The VLAD charts generated for each centre displayed trends in outcomes benchmarked to recent national outcomes. All centres ended the 2-year period within four deaths from what would be expected. The VLAD charts were shared in multidisciplinary meetings and clinical teams reported that they were a useful addition to existing quality assurance initiatives. Each centre is continuing to use the prototype software to monitor their in-house surgical outcomes. Conclusions Timely and routine monitoring of risk-adjusted mortality following paediatric cardiac surgery is feasible. Close liaison with hospital data managers as well as clinicians was crucial to the success of the project. PMID:23564473
Cundell, A M; Bean, R; Massimore, L; Maier, C
1998-01-01
To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.
FPGA Implementation of Heart Rate Monitoring System.
Panigrahy, D; Rakshit, M; Sahu, P K
2016-03-01
This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.
Transforming the NAS: The Next Generation Air Traffic Control System
NASA Technical Reports Server (NTRS)
Erzberger, Heinz
2004-01-01
The next-generation air traffic control system must be designed to safely and efficiently accommodate the large growth of traffic expected in the near future. It should be sufficiently scalable to contend with the factor of 2 or more increase in demand expected by the year 2020. Analysis has shown that the current method of controlling air traffic cannot be scaled up to provide such levels of capacity. Therefore, to achieve a large increase in capacity while also giving pilots increased freedom to optimize their flight trajectories requires a fundamental change in the way air traffic is controlled. The key to achieving a factor of 2 or more increase in airspace capacity is to automate separation monitoring and control and to use an air-ground data link to send trajectories and clearances directly between ground-based and airborne systems. In addition to increasing capacity and offering greater flexibility in the selection of trajectories, this approach also has the potential to increase safety by reducing controller and pilot errors that occur in routine monitoring and voice communication tasks.
Sustainable Monitoring and Surveillance Systems to Improve HIV Programs: Review.
Low-Beer, Daniel; Mahy, Mary; Renaud, Francoise; Calleja, Txema
2018-04-24
HIV programs have provided a major impetus for investments in surveillance data, with 5-10% of HIV program budgets recommended to support data. However there are questions concerning the sustainability of these investments. The Sustainable Development Goals have consolidated health into one goal and communicable diseases into one target (Target 3.3). Sustainable Development Goals now introduce targets focused specifically on data (Targets 17.18 and 17.19). Data are seen as one of the three systemic issues (in Goal 17) for implementing Sustainable Development Goals, alongside policies and partnerships. This paper reviews the surveillance priorities in the context of the Sustainable Development Goals and highlights the shift from periodic measurement towards sustainable disaggregated, real-time, case, and patient data, which are used routinely to improve programs. Finally, the key directions in developing person-centered monitoring systems are assessed with country examples. The directions contribute to the Sustainable Development Goal focus on people-centered development applied to data. ©Daniel Low-Beer, Mary Mahy, Francoise Renaud, Txema Calleja. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 24.04.2018.
Manes, Gianfranco; Collodi, Giovanni; Gelpi, Leonardo; Fusco, Rosanna; Ricci, Giuseppe; Manes, Antonio; Passafiume, Marco
2016-01-20
This paper describes a distributed point-source monitoring platform for gas level and leakage detection in hazardous environments. The platform, based on a wireless sensor network (WSN) architecture, is organised into sub-networks to be positioned in the plant's critical areas; each sub-net includes a gateway unit wirelessly connected to the WSN nodes, hence providing an easily deployable, stand-alone infrastructure featuring a high degree of scalability and reconfigurability. Furthermore, the system provides automated calibration routines which can be accomplished by non-specialized maintenance operators without system reliability reduction issues. Internet connectivity is provided via TCP/IP over GPRS (Internet standard protocols over mobile networks) gateways at a one-minute sampling rate. Environmental and process data are forwarded to a remote server and made available to authenticated users through a user interface that provides data rendering in various formats and multi-sensor data fusion. The platform is able to provide real-time plant management with an effective; accurate tool for immediate warning in case of critical events.
Toxin detection using a tyrosinase-coupled oxygen electrode.
Smit, M H; Rechnitz, G A
1993-02-15
An enzyme-based "electrochemical canary" is described for the detection of cyanide. The sensing system imitates cyanide's site of toxicity in the mitochondria. The terminal sequence of electron transfer in aerobic respiration is mimicked by mediator coupling of tyrosinase catalysis to an electro-chemical system. An enzyme-coupled oxygen electrode is created which is sensitive to selective poisoning. Biocatalytic reduction of oxygen is promoted by electrochemically supplying tyrosinase with electrons. Thus, ferrocyanide is generated at a cathode and mediates the enzymatic reduction of oxygen to water. An enzyme-dependent reductive current can be monitored which is inhibited by cyanide in a concentration-dependent manner. Oxygen depletion in the reaction layer can be minimized by addressing enzyme activity using a potential pulsing routine. Enzyme activity is electrochemically initiated and terminated and the sensor becomes capable of continuous monitoring. Cyanide poisoning of the biological component is reversible, and it can be reused after rinsing. The resulting sensor detects cyanide based on its biological activity rather than its physical or chemical properties.
Current techniques in acid-chloride corrosion control and monitoring at The Geysers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hirtz, Paul; Buck, Cliff; Kunzman, Russell
1991-01-01
Acid chloride corrosion of geothermal well casings, production piping and power plant equipment has resulted in costly corrosion damage, frequent curtailments of power plants and the permanent shut-in of wells in certain areas of The Geysers. Techniques have been developed to mitigate these corrosion problems, allowing continued production of steam from high chloride wells with minimal impact on production and power generation facilities.The optimization of water and caustic steam scrubbing, steam/liquid separation and process fluid chemistry has led to effective and reliable corrosion mitigation systems currently in routine use at The Geysers. When properly operated, these systems can yield steammore » purities equal to or greater than those encountered in areas of The Geysers where chloride corrosion is not a problem. Developments in corrosion monitoring techniques, steam sampling and analytical methodologies for trace impurities, and computer modeling of the fluid chemistry has been instrumental in the success of this technology.« less
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin
2011-01-01
The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.
NASA Astrophysics Data System (ADS)
Nagel, David J.
2000-11-01
The coordinated exploitation of modern communication, micro- sensor and computer technologies makes it possible to give global reach to our senses. Web-cameras for vision, web- microphones for hearing and web-'noses' for smelling, plus the abilities to sense many factors we cannot ordinarily perceive, are either available or will be soon. Applications include (1) determination of weather and environmental conditions on dense grids or over large areas, (2) monitoring of energy usage in buildings, (3) sensing the condition of hardware in electrical power distribution and information systems, (4) improving process control and other manufacturing, (5) development of intelligent terrestrial, marine, aeronautical and space transportation systems, (6) managing the continuum of routine security monitoring, diverse crises and military actions, and (7) medicine, notably the monitoring of the physiology and living conditions of individuals. Some of the emerging capabilities, such as the ability to measure remotely the conditions inside of people in real time, raise interesting social concerns centered on privacy issues. Methods for sensor data fusion and designs for human-computer interfaces are both crucial for the full realization of the potential of pervasive sensing. Computer-generated virtual reality, augmented with real-time sensor data, should be an effective means for presenting information from distributed sensors.
An Interoperable Architecture for Air Pollution Early Warning System Based on Sensor Web
NASA Astrophysics Data System (ADS)
Samadzadegan, F.; Zahmatkesh, H.; Saber, M.; Ghazi khanlou, H. J.
2013-09-01
Environmental monitoring systems deal with time-sensitive issues which require quick responses in emergency situations. Handling the sensor observations in near real-time and obtaining valuable information is challenging issues in these systems from a technical and scientific point of view. The ever-increasing population growth in urban areas has caused certain problems in developing countries, which has direct or indirect impact on human life. One of applicable solution for controlling and managing air quality by considering real time and update air quality information gathered by spatially distributed sensors in mega cities, using sensor web technology for developing monitoring and early warning systems. Urban air quality monitoring systems using functionalities of geospatial information system as a platform for analysing, processing, and visualization of data in combination with Sensor Web for supporting decision support systems in disaster management and emergency situations. This system uses Sensor Web Enablement (SWE) framework of the Open Geospatial Consortium (OGC), which offers a standard framework that allows the integration of sensors and sensor data into spatial data infrastructures. SWE framework introduces standards for services to access sensor data and discover events from sensor data streams as well as definition set of standards for the description of sensors and the encoding of measurements. The presented system provides capabilities to collect, transfer, share, process air quality sensor data and disseminate air quality status in real-time. It is possible to overcome interoperability challenges by using standard framework. In a routine scenario, air quality data measured by in-situ sensors are communicated to central station where data is analysed and processed. The extracted air quality status is processed for discovering emergency situations, and if necessary air quality reports are sent to the authorities. This research proposed an architecture to represent how integrate air quality sensor data stream into geospatial data infrastructure to present an interoperable air quality monitoring system for supporting disaster management systems by real time information. Developed system tested on Tehran air pollution sensors for calculating Air Quality Index (AQI) for CO pollutant and subsequently notifying registered users in emergency cases by sending warning E-mails. Air quality monitoring portal used to retrieving and visualize sensor observation through interoperable framework. This system provides capabilities to retrieve SOS observation using WPS in a cascaded service chaining pattern for monitoring trend of timely sensor observation.
200-BP-1 Prototype Hanford Barrier -- 15 Years of Performance Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, Anderson L.; Draper, Kathryn E.; Link, Steven O.
2011-09-30
Monitoring is an essential component of engineered barrier system design and operation. A composite capacitive cover, including a capillary break and an evapotranspiration (ET) barrier at the Hanford Site, is generating data that can be used to help resolve these issues. The prototype Hanford barrier was constructed over the 216-B-57 Crib in 1994 to evaluate surface-barrier constructability, construction costs, and physical and hydrologic performance at the field scale. The barrier has been routinely monitored between November 1994 and September 1998 as part of a Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) treatability test of barrier performance formore » the 200 BP 1 Operable Unit. Since FY 1998, monitoring has focused on a more limited set of key water balance, stability, and biotic parameters. In FY 2009, data collection was focused on: (1) water-balance monitoring, consisting of precipitation, runoff, soil moisture storage, and drainage measurements with evapotranspiration calculated by difference; (2) stability monitoring, consisting of asphalt-layer-settlement, basalt-side-slope-stability, and surface-elevation measurements; (3) vegetation dynamics; and (4) animal use. September 2009 marked 15 years since the start of monitoring and the collection of performance data. This report describes the results of monitoring activities during the period October 1, 2008, through September 30, 2009, and summarizes the 15 years of performance data collected from September 1994 through September 2009.« less
AI in medicine on its way from knowledge-intensive to data-intensive systems.
Horn, W
2001-08-01
The last 20 years of research and development in the field of artificial intelligence in medicine (AIM) show a path from knowledge-intensive systems, which try to capture the essential knowledge of experts in a knowledge-based system, to data-intensive systems available today. Nowadays enormous amounts of information is accessible electronically. Large datasets are collected continuously monitoring physiological parameters of patients. Knowledge-based systems are needed to make use of all these data available and to help us to cope with the information explosion. In addition, temporal data analysis and intelligent information visualization can help us to get a summarized view of the change over time of clinical parameters. Integrating AIM modules into the daily-routine software environment of our care providers gives us a great chance for maintaining and improving quality of care.
Consulting report on the NASA technology utilization network system
NASA Technical Reports Server (NTRS)
Hlava, Marjorie M. K.
1992-01-01
The purposes of this consulting effort are: (1) to evaluate the existing management and production procedures and workflow as they each relate to the successful development, utilization, and implementation of the NASA Technology Utilization Network System (TUNS) database; (2) to identify, as requested by the NASA Project Monitor, the strengths, weaknesses, areas of bottlenecking, and previously unaddressed problem areas affecting TUNS; (3) to recommend changes or modifications of existing procedures as necessary in order to effect corrections for the overall benefit of NASA TUNS database production, implementation, and utilization; and (4) to recommend the addition of alternative procedures, routines, and activities that will consolidate and facilitate the production, implementation, and utilization of the NASA TUNS database.
Mesquita, D P; Dias, O; Amaral, A L; Ferreira, E C
2009-04-01
In recent years, a great deal of attention has been focused on the research of activated sludge processes, where the solid-liquid separation phase is frequently considered of critical importance, due to the different problems that severely affect the compaction and the settling of the sludge. Bearing that in mind, in this work, image analysis routines were developed in Matlab environment, allowing the identification and characterization of microbial aggregates and protruding filaments in eight different wastewater treatment plants, for a combined period of 2 years. The monitoring of the activated sludge contents allowed for the detection of bulking events proving that the developed image analysis methodology is adequate for a continuous examination of the morphological changes in microbial aggregates and subsequent estimation of the sludge volume index. In fact, the obtained results proved that the developed image analysis methodology is a feasible method for the continuous monitoring of activated sludge systems and identification of disturbances.
Resistance monitoring of human pathogenic bacteria in Germany, SWOT analysis and examples.
Witte, Wolfgang
2006-06-01
Determination of antibiotic resistance has two main goals in clinical-microbiological diagnosis. One aspect is preservation of antibacterial chemotherapy. Furthermore, trends in resistance development should be monitored and should serve as an early warning-system for occurrence and spread of new and clinically important antibiotic resistances. Plenty of data on antibiotic resistance is gathered on a routine basis in medical-microbiological diagnosis and often it is stored in electronic databases that could be interlinked. The main reason that the available data is not being used for resistance monitoring in Germany is the widely used methodology of the agar diffusion test. It is the cheapest and by far the most inaccurate method of determining resistance. The test results are not always comparable with tests for all substance groups from national standards (also limited international comparability). Trend analysis of the resistance situation in Germany can therefore only be determined through individual studies. These studies are discussed according to a SWOT analysis (SWOT = Strengths, Weaknesses, Opportunities, Threats).
Advances in Developing HIV-1 Viral Load Assays for Resource-Limited Settings
Wang, ShuQi; Xu, Feng; Demirci, Utkan
2010-01-01
Commercial HIV-1 RNA viral load assays have been routinely used in developed countries to monitor antiretroviral treatment (ART). However, these assays require expensive equipment and reagents, well-trained operators, and established laboratory infrastructure. These requirements restrict their use in resource-limited settings where people are most afflicted with the HIV-1 epidemic. Inexpensive alternatives such as the Ultrasensitive p24 assay, the Reverse Transcriptase (RT) assay and in-house reverse transcription quantitative polymerase chain reaction (RT-qPCR) have been developed. However, they are still time-consuming, technologically complex and inappropriate for decentralized laboratories as point-of-care (POC) tests. Recent advances in microfluidics and nanotechnology offer new strategies to develop low-cost, rapid, robust and simple HIV-1 viral load monitoring systems. We review state-of-the-art technologies used for HIV-1 viral load monitoring in both developed and developing settings. Emerging approaches based on microfluidics and nanotechnology, which have potential to be integrated into POC HIV-1 viral load assays, are also discussed. PMID:20600784
Bluetooth technology for prevention of dental caries.
Kolahi, Jafar; Fazilati, Mohamad
2009-12-01
Caries is caused when the pH at the tooth surface drops below 5.5. A miniaturized and autonomous pH monitoring nodes can be attached to the tooth surface, like a tooth jewel. This intelligent sensor includes three components: (a) digital micro pH meter, (b) power supply, (c) wireless communicating device. The micro pH meter facilitates long term tooth surface pH monitoring and providing real time feedback to the patients and dental experts. Power supply of this system will be microfabricated biocatalytic fuel cell (enzymatic micro-battery) using organic compounds (e.g. formate or glucose) as the fuel to generate electricity. When micro pH meter detects the pH lower than 5.5, wireless Bluetooth device sends a caution (e.g. "you are at risk of dental caries") to external monitoring equipment such as mobile phone or a hands-free heads. After reception of the caution, subjects should use routine brushing and flossing procedure or use a medicated chewing gum (e.g. chlorhexidine containing chewing gum) or rinse with a mouthwash.
Detecting Gunshots Using Wearable Accelerometers
Loeffler, Charles E.
2014-01-01
Gun violence continues to be a staggering and seemingly intractable issue in many communities. The prevalence of gun violence among the sub-population of individuals under court-ordered community supervision provides an opportunity for intervention using remote monitoring technology. Existing monitoring systems rely heavily on location-based monitoring methods, which have incomplete geographic coverage and do not provide information on illegal firearm use. This paper presents the first results demonstrating the feasibility of using wearable inertial sensors to recognize wrist movements and other signals corresponding to firearm usage. Data were collected from accelerometers worn on the wrists of subjects shooting a number of different firearms, conducting routine daily activities, and participating in activities and tasks that could be potentially confused with firearm discharges. A training sample was used to construct a combined detector and classifier for individual gunshots, which achieved a classification accuracy of 99.4 percent when tested against a hold-out sample of observations. These results suggest the feasibility of using inexpensive wearable sensors to detect firearm discharges. PMID:25184416
Detecting gunshots using wearable accelerometers.
Loeffler, Charles E
2014-01-01
Gun violence continues to be a staggering and seemingly intractable issue in many communities. The prevalence of gun violence among the sub-population of individuals under court-ordered community supervision provides an opportunity for intervention using remote monitoring technology. Existing monitoring systems rely heavily on location-based monitoring methods, which have incomplete geographic coverage and do not provide information on illegal firearm use. This paper presents the first results demonstrating the feasibility of using wearable inertial sensors to recognize wrist movements and other signals corresponding to firearm usage. Data were collected from accelerometers worn on the wrists of subjects shooting a number of different firearms, conducting routine daily activities, and participating in activities and tasks that could be potentially confused with firearm discharges. A training sample was used to construct a combined detector and classifier for individual gunshots, which achieved a classification accuracy of 99.4 percent when tested against a hold-out sample of observations. These results suggest the feasibility of using inexpensive wearable sensors to detect firearm discharges.
Tambo, Ernest; Khayeka-Wandabwa, Christopher; Olalubi, Oluwasogo A; Adedeji, Ahmed A; Ngogang, Jeanne Y; Khater, Emad Im
2017-05-01
Globalization, with consequent increased travel and trade, rapid urbanization and growing weather variation events due to climate change has contributed to the recent unprecedented Zika virus (ZIKV) pandemic. This has emphasized the pressing need for local, national, regional and global community collaborative proactiveness, leadership and financial investment resilience in research and development. This paper addresses the potential knowledge gaps and impact of early detection and monitoring approaches on ZIKV epidemics and related arboviral infections steered towards effective prevention and smart response strategies. We advocate for the development and validation of robust field and point of care diagnostic tools that are more sensitive, specific and cost effective for use in ZIKV epidemics and routine pathophysiology surveillance and monitoring systems as an imperative avenue in understanding Zika-related and other arbovirus trends and apply genomic and proteomic characterisation approaches in guiding annotation efforts in order to design and implement public health burden mitigation and adaptation strategies.
Ubiquitous health monitoring system for multiple users using a ZigBee and WLAN dual-network.
Cha, Yong Dae; Yoon, Gilwon
2009-11-01
A ubiquitous health monitoring system for multiple users was developed based on a ZigBee and wireless local area network (WLAN) dual-network. A compact biosignal monitoring unit (BMU) for measuring electrocardiogram (ECG), photoplethysmogram (PPG), and temperature was also developed. A single 8-bit microcontroller operated the BMU including most of digital filtering and wireless communication. The BMU with its case was reduced to 55 x 35 x 15 mm and 33 g. In routine use, vital signs of 6 bytes/sec (heart rate, temperature, pulse transit time) per each user were transmitted through a ZigBee module even though all the real-time data were recorded in a secure digital memory of the BMU. In an emergency or when need arises, a channel of a particular user was switched to another ZigBee module, called the emergency module, that sent all ECG and PPG waveforms in real time. Each emergency ZigBee module handled up to a few users. Data from multiple users were wirelessly received by the ZigBee receiver modules in a controller called ZigBee-WLAN gateway, where the ZigBee modules were connected to a WLAN module. This WLAN module sent all data wirelessly to a monitoring center. Operating the dual modes of ZigBee/WLAN utilized an advantage of ZigBee by handling multiple users with minimum power consumption, and overcame the ZigBee limitation of low data rate. This dual-network system for LAN is economically competitive and reliable.
NASA Astrophysics Data System (ADS)
Geng, T.
2015-12-01
Nowadays more and more high-rate Global Navigation Satellite Systems (GNSS) data become available in real time, which provide more opportunities to monitor the seismic waveforms. China's GNSS, BeiDou Navigation Satellite System (BDS), has already satisfied the requirement of stand-alone precise positioning in Asia-Pacific region with 14 in-orbit satellites, which promisingly suggests that BDS could be applied to the high-precision earthquake monitoring as GPS. In the present paper, real-time monitoring of seismic waveforms using BDS measurements is assessed. We investigate a so-called "variometric" approach to measure real-time seismic waveforms with high-rate BDS observations. This approach is based on time difference technique and standard broadcast products which are routinely available in real time. The 1HZ BDS data recorded by Beidou Experimental Tracking Stations (BETS) during the 2015 Mw 7.8 Nepal earthquake is analyzed. The results indicate that the accuracies of velocity estimation from BDS are 2-3 mm/s in horizontal components and 8-9 mm/s in vertical component, respectively, which are consistent with GPS. The seismic velocity waveforms during earthquake show good agreement between BDS and GPS. Moreover, the displacement waveforms is reconstructed by an integration of velocity time series with trend removal. The displacement waveforms with the accuracy of 1-2 cm are derived by comparing with post-processing GPS precise point positioning (PPP).
49 CFR 240.129 - Criteria for monitoring operational performance of certified engineers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... railroad's rules and practices for the safe operation of locomotives and trains; (2) Be designed so that... service. (c) The procedures shall: (1) Be designed to determine that the person possesses and routinely... operational performance monitoring will be conducted; (3) Be designed so that the locomotive engineer is...
Operating system for a real-time multiprocessor propulsion system simulator
NASA Technical Reports Server (NTRS)
Cole, G. L.
1984-01-01
The success of the Real Time Multiprocessor Operating System (RTMPOS) in the development and evaluation of experimental hardware and software systems for real time interactive simulation of air breathing propulsion systems was evaluated. The Real Time Multiprocessor Operating System (RTMPOS) provides the user with a versatile, interactive means for loading, running, debugging and obtaining results from a multiprocessor based simulator. A front end processor (FEP) serves as the simulator controller and interface between the user and the simulator. These functions are facilitated by the RTMPOS which resides on the FEP. The RTMPOS acts in conjunction with the FEP's manufacturer supplied disk operating system that provides typical utilities like an assembler, linkage editor, text editor, file handling services, etc. Once a simulation is formulated, the RTMPOS provides for engineering level, run time operations such as loading, modifying and specifying computation flow of programs, simulator mode control, data handling and run time monitoring. Run time monitoring is a powerful feature of RTMPOS that allows the user to record all actions taken during a simulation session and to receive advisories from the simulator via the FEP. The RTMPOS is programmed mainly in PASCAL along with some assembly language routines. The RTMPOS software is easily modified to be applicable to hardware from different manufacturers.
Patient data system for monitoring shunts.
Frank, E; Su, E; Smith, K
1988-01-01
Rapidly locating accurate data on a patient's shunt system is often extremely difficult. We have developed a simple system to fill a perceived need for recording current data on a patients shunt. This system employs an easily updated record in the patient's hospital or clinic chart as well as a wallet-sized data card for the patient or his family to carry. The data in the chart include the configuration of the patient's current shunt system and a graphic record of previous shunt problems. The small patient data card describes the age of the shunt system and its current configuration. We have found that this system provides assistance in the routine follow-up of patients with shunts and plays an extremely necessary role in the emergency evaluation of these patients, particularly when an emergency evaluation is undertaken in facilities distant from the location of regular treatment.
Eldawlatly, Abdelazeem; El-Tahan, Mohamed R
2013-04-01
This survey aimed to assess the extent of practice of the Middle Eastern anesthesiologists in the use of neuromuscular blocking agents (NMB) in 2012. We distributed an electronic survey among 577 members of the Triple-M Middle Eastern Yahoo anesthesia group, enquiring about their practice in the use of neuromuscular blocking agents. Questions concerned the routine first choice use of NMB, choice for tracheal intubation, the use of neuromuscular monitoring (NMT), type of NMB used in difficult airway, frequency of using suxamethonium, cisatracurium, rocuronium and sugammadex, observed side effects of rocuronium, residual curarization, and the reversal of residual curarization of rocuronium. A total of 71 responses from 22 Middle Eastern institutions were collected. Most of the Middle Eastern anesthesiologists were using cisatracurium and rocuronium frequently for tracheal intubation (39% and 35%, respectively). From the respondents, 2/3 were using suxamethonium for tracheal intubation in difficult airway, 1/3 were using rocuronium routinely and 17% have observed hypersensitivity reactions to rocuronium, 54% reported residual curarization from rocuronium, 78% were routinely using neostigmine to reverse the rocuronium, 21% used sugammadex occasionally, and 35% were using NMT routinely during the use of NMB. We believe that more could be done to increase the awareness of the Middle Eastern anesthesiologists about the high incidence of PROC (>20%) and the need for routine monitoring of neuromuscular function. This could be accomplished with by developing formal training programs and providing official guidelines.
Varley, Adam; Tyler, Andrew; Smith, Leslie; Dale, Paul; Davies, Mike
2015-07-15
The extensive use of radium during the 20th century for industrial, military and pharmaceutical purposes has led to a large number of contaminated legacy sites across Europe and North America. Sites that pose a high risk to the general public can present expensive and long-term remediation projects. Often the most pragmatic remediation approach is through routine monitoring operating gamma-ray detectors to identify, in real-time, the signal from the most hazardous heterogeneous contamination (hot particles); thus facilitating their removal and safe disposal. However, current detection systems do not fully utilise all spectral information resulting in low detection rates and ultimately an increased risk to the human health. The aim of this study was to establish an optimised detector-algorithm combination. To achieve this, field data was collected using two handheld detectors (sodium iodide and lanthanum bromide) and a number of Monte Carlo simulated hot particles were randomly injected into the field data. This allowed for the detection rate of conventional deterministic (gross counts) and machine learning (neural networks and support vector machines) algorithms to be assessed. The results demonstrated that a Neural Network operated on a sodium iodide detector provided the best detection capability. Compared to deterministic approaches, this optimised detection system could detect a hot particle on average 10cm deeper into the soil column or with half of the activity at the same depth. It was also found that noise presented by internal contamination restricted lanthanum bromide for this application. Copyright © 2015. Published by Elsevier B.V.
Revolutionary optical sensor for physiological monitoring in the battlefield
NASA Astrophysics Data System (ADS)
Kingsley, Stuart A.; Sriram, Sriram; Pollick, Andrea; Marsh, John
2004-09-01
SRICO has developed a revolutionary approach to physiological status monitoring using state-of-the-art optical chip technology. The company"s patent pending Photrode is a photonic electrode that uses unique optical voltage sensing technology to measure and monitor electrophysiological parameters. The optical-based monitoring system enables dry-contact measurements of EEG and ECG signals that require no surface preparation or conductive gel and non-contact measurements of ECG signals through the clothing. The Photrode applies high performance optical integrated circuit technology, that has been successfully implemented in military & commercial aerospace, missile, and communications applications for sensing and signal transmission. SRICO"s award winning Photrode represents a new paradigm for the measurement of biopotentials in a reliable, convenient, and non-intrusive manner. Photrode technology has significant applications on the battlefield for rapid triage to determine the brain dead from those with viable brain function. An ECG may be obtained over the clothing without any direct skin contact. Such applications would enable the combat medic to receive timely medical information and to make important decisions regarding identification, location, triage priority and treatment of casualties. Other applications for the Photrode include anesthesia awareness monitoring, sleep medicine, mobile medical monitoring for space flight, emergency patient care, functional magnetic resonance imaging, various biopotential signal acquisition (EMG, EOG), and routine neuro and cardio diagnostics.
Eating routines: Embedded, value based, modifiable, and reflective
Jastran, Margaret; Bisogni, Carole A.; Sobal, Jeffery; Blake, Christine; Devine, Carol M.
2009-01-01
Eating routines are a compelling issue because recurring eating behaviors influence nutrition and health. As non-traditional and individualized eating patterns have become more common, new ways of thinking about routine eating practices are needed. This study sought to gain conceptual understanding of working adults' eating routines. Forty-two purposively sampled US adults reported food intake and contextual details about eating episodes in qualitative 24-hour dietary recalls conducted over 7 consecutive days. Using the constant comparative method, researchers analyzed interview transcripts for recurrent ways of eating that were either explicitly reported by study participants as “routines” or emergent in the data. Participants' eating routines included repetition in food consumption as well as eating context, and also involved sequences of eating episodes. Eating routines were embedded in daily schedules for work, family, and recreation. Participants maintained purposeful routines that helped balance tension between demands and values, but they modified routines as circumstances changed. Participants monitored and reflected upon their eating practices and tended to assess their practices in light of their personal identities. These findings provide conceptual insights for food choice researchers and present a perspective from which practitioners who work with individuals seeking to adopt healthful eating practices might usefully approach their tasks. PMID:18835305
NASA Astrophysics Data System (ADS)
Walsh, Alex J.; Skala, Melissa C.
2014-02-01
The heterogeneity of genotypes and phenotypes within cancers is correlated with disease progression and drug-resistant cellular sub-populations. Therefore, robust techniques capable of probing majority and minority cell populations are important both for cancer diagnostics and therapy monitoring. Herein, we present a modified CellProfiler routine to isolate cytoplasmic fluorescence signal on a single cell level from high resolution auto-fluorescence microscopic images.
Barkhausen, Jörg; Kahn, Thomas; Krombach, Gabriele A; Kuhl, Christiane K; Lotz, Joachim; Maintz, David; Ricke, Jens; Schönberg, Stefan O; Vogl, Thomas J; Wacker, Frank K
2017-07-01
Background MRI is attractive for the guiding and monitoring of interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure physiologic parameters like flow and cardiac function. Method The current status of interventional MRI for the clinical routine was analyzed. Results The effort needed for the development of MR-safe monitoring systems and instruments initially resulted in the application of interventional MRI only for procedures that could not be performed by other means. Accordingly, biopsy of lesions in the breast, which are not detectable by other modalities, has been performed under MRI guidance for decades. Currently, biopsies of the prostate under MRI guidance are established in a similar fashion. At many sites blind biopsy has already been replaced by MR-guided biopsy or at least by the fusion of MR images with ultrasound. Cardiovascular interventions are performed at several centers for ablation as a treatment for atrial fibrillation. Conclusion Interventional MRI has been established in the clinical routine for a variety of indications. Broader application can be expected in the clinical routine in the future owing to the multiple advantages compared to other techniques. Key points · Due to the significant technical effort, MR-guided interventions are only recommended in the long term for regions in which MRI either facilitates or greatly improves the intervention.. · Breast biopsy of otherwise undetectable target lesions has long been established in the clinical routine. Prostate biopsy is currently being introduced in the clinical routine for similar reasons. Other methods such as MR-guided focused ultrasound for the treatment of uterine fibroids or tumor ablation of metastases represent alternative methods and are offered in many places.. · Endovascular MR-guided interventions offer advantages for a number of indications and have already been clinically established for the treatment of children with congenital heart defects and for atrial ablation at individual centers. Greater application can be expected in the future.. Citation format · Barkhausen J, Kahn T, Krombach GA et al. White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application. Fortschr Röntgenstr 2017; 189: 611 - 623. © Georg Thieme Verlag KG Stuttgart · New York.
Yuval, Yuval; Rimon, Yaara; Graber, Ellen R; Furman, Alex
2014-08-01
A large fraction of the fresh water available for human use is stored in groundwater aquifers. Since human activities such as mining, agriculture, industry and urbanisation often result in incursion of various pollutants to groundwater, routine monitoring of water quality is an indispensable component of judicious aquifer management. Unfortunately, groundwater pollution monitoring is expensive and usually cannot cover an aquifer with the spatial resolution necessary for making adequate management decisions. Interpolation of monitoring data is thus an important tool for supplementing monitoring observations. However, interpolating routine groundwater pollution data poses a special problem due to the nature of the observations. The data from a producing aquifer usually includes many zero pollution concentration values from the clean parts of the aquifer but may span a wide range of values (up to a few orders of magnitude) in the polluted areas. This manuscript presents a methodology that can cope with such datasets and use them to produce maps that present the pollution plumes but also delineates the clean areas that are fit for production. A method for assessing the quality of mapping in a way which is suitable to the data's dynamic range of values is also presented. A local variant of inverse distance weighting is employed to interpolate the data. Inclusion zones around the interpolation points ensure that only relevant observations contribute to each interpolated concentration. Using inclusion zones improves the accuracy of the mapping but results in interpolation grid points which are not assigned a value. The inherent trade-off between the interpolation accuracy and coverage is demonstrated using both circular and elliptical inclusion zones. A leave-one-out cross testing is used to assess and compare the performance of the interpolations. The methodology is demonstrated using groundwater pollution monitoring data from the coastal aquifer along the Israeli shoreline. The implications for aquifer management are discussed.
Gene-expression profiling for rejection surveillance after cardiac transplantation.
Pham, Michael X; Teuteberg, Jeffrey J; Kfoury, Abdallah G; Starling, Randall C; Deng, Mario C; Cappola, Thomas P; Kao, Andrew; Anderson, Allen S; Cotts, William G; Ewald, Gregory A; Baran, David A; Bogaev, Roberta C; Elashoff, Barbara; Baron, Helen; Yee, James; Valantine, Hannah A
2010-05-20
Endomyocardial biopsy is the standard method of monitoring for rejection in recipients of a cardiac transplant. However, this procedure is uncomfortable, and there are risks associated with it. Gene-expression profiling of peripheral-blood specimens has been shown to correlate with the results of an endomyocardial biopsy. We randomly assigned 602 patients who had undergone cardiac transplantation 6 months to 5 years previously to be monitored for rejection with the use of gene-expression profiling or with the use of routine endomyocardial biopsies, in addition to clinical and echocardiographic assessment of graft function. We performed a noninferiority comparison of the two approaches with respect to the composite primary outcome of rejection with hemodynamic compromise, graft dysfunction due to other causes, death, or retransplantation. During a median follow-up period of 19 months, patients who were monitored with gene-expression profiling and those who underwent routine biopsies had similar 2-year cumulative rates of the composite primary outcome (14.5% and 15.3%, respectively; hazard ratio with gene-expression profiling, 1.04; 95% confidence interval, 0.67 to 1.68). The 2-year rates of death from any cause were also similar in the two groups (6.3% and 5.5%, respectively; P=0.82). Patients who were monitored with the use of gene-expression profiling underwent fewer biopsies per person-year of follow-up than did patients who were monitored with the use of endomyocardial biopsies (0.5 vs. 3.0, P<0.001). Among selected patients who had received a cardiac transplant more than 6 months previously and who were at a low risk for rejection, a strategy of monitoring for rejection that involved gene-expression profiling, as compared with routine biopsies, was not associated with an increased risk of serious adverse outcomes and resulted in the performance of significantly fewer biopsies. (ClinicalTrials.gov number, NCT00351559.) 2010 Massachusetts Medical Society
NASA Technical Reports Server (NTRS)
Stephens, J. B.
1976-01-01
The National Aeronautics and Space Administration/Marshall Space Flight Center multilayer diffusion algorithms have been specialized for the prediction of the surface impact for the dispersive transport of the exhaust effluents from the launch of a Delta-Thor vehicle. This specialization permits these transport predictions to be made at the launch range in real time so that the effluent monitoring teams can optimize their monitoring grids. Basically, the data reduction routine requires only the meteorology profiles for the thermodynamics and kinematics of the atmosphere as an input. These profiles are graphed along with the resulting exhaust cloud rise history, the centerline concentrations and dosages, and the hydrogen chloride isopleths.
Papneja, Koyelle; Bhatt, Mihir D; Kirby-Allen, Melanie; Arora, Steven; Wiernikowski, John T; Athale, Uma H
2016-08-01
Deferasirox is an oral iron chelator used to treat patients with transfusion-related iron overload. We report, from two institutions, two children with Diamond-Blackfan anemia who developed Fanconi syndrome secondary to deferasirox administration, along with a review of the literature. The current recommendation for the laboratory monitoring of patients receiving deferasirox does not include serum electrolytes or urine analysis. Thus, despite routine clinic visits and bloodwork, these two patients presented with life-threatening electrolyte abnormalities requiring hospitalization. Hence, we propose the inclusion of serum electrolytes and urine analysis as part of routine monitoring to facilitate the early diagnosis of Fanconi syndrome in the context of high doses of deferasirox therapy. © 2016 Wiley Periodicals, Inc.
From Caprio's lilacs to the USA National Phenology Network
Schwartz, Mark D.; Betancourt, Julio L.; Weltzin, Jake F.
2012-01-01
Continental-scale monitoring is vital for understanding and adapting to temporal changes in seasonal climate and associated phenological responses. The success of monitoring programs will depend on recruiting, retaining, and managing members of the public to routinely collect phenological observations according to standardized protocols. Here, we trace the development of infrastructure for phenological monitoring in the US, culminating in the USA National Phenology Network, a program that engages scientists and volunteers.
Production and use of estimates for monitoring progress in the health sector: the case of Bangladesh
Ahsan, Karar Zunaid; Tahsina, Tazeen; Iqbal, Afrin; Ali, Nazia Binte; Chowdhury, Suman Kanti; Huda, Tanvir M.; Arifeen, Shams El
2017-01-01
ABSTRACT Background: In order to support the progress towards the post-2015 development agenda for the health sector, the importance of high-quality and timely estimates has become evident both globally and at the country level. Objective and Methods: Based on desk review, key informant interviews and expert panel discussions, the paper critically reviews health estimates from both the local (i.e. nationally generated information by the government and other agencies) and the global sources (which are mostly modeled or interpolated estimates developed by international organizations based on different sources of information), and assesses the country capacity and monitoring strategies to meet the increasing data demand in the coming years. Primarily, this paper provides a situation analysis of Bangladesh in terms of production and use of health estimates for monitoring progress towards the post-2015 development goals for the health sector. Results: The analysis reveals that Bangladesh is data rich, particularly from household surveys and health facility assessments. Practices of data utilization also exist, with wide acceptability of survey results for informing policy, programme review and course corrections. Despite high data availability from multiple sources, the country capacity for providing regular updates of major global health estimates/indicators remains low. Major challenges also include limited human resources, capacity to generate quality data and multiplicity of data sources, where discrepancy and lack of linkages among different data sources (local sources and between local and global estimates) present emerging challenges for interpretation of the resulting estimates. Conclusion: To fulfill the increased data requirement for the post-2015 era, Bangladesh needs to invest more in electronic data capture and routine health information systems. Streamlining of data sources, integration of parallel information systems into a common platform, and capacity building for data generation and analysis are recommended as priority actions for Bangladesh in the coming years. In addition to automation of routine health information systems, establishing an Indicator Reference Group for Bangladesh to analyze data; building country capacity in data quality assessment and triangulation; and feeding into global, inter-agency estimates for better reporting would address a number of mentioned challenges in the short- and long-run. PMID:28532305
Design of a spreader bar crane-mounted gamma-ray radiation detection system
NASA Astrophysics Data System (ADS)
Grypp, Matthew D.; Marianno, Craig M.; Poston, John W.; Hearn, Gentry C.
2014-04-01
Over 95% of imports entering the United States from outside North America arrive by sea at 329 ports of entry. These imports are packaged in more than 11 million cargo containers. Radiation portals monitors routinely scan cargo containers leaving port on specially-designed trucks. To accelerate the process, some commercial entities have placed detection systems on the spreader-bar cranes (SBCs) used to offload. Little is known about the radiation background profiles of systems operating on these cranes. To better understand the operational characteristics of these radiation detection systems; a research team from Texas A&M University (TAMU) mounted three thallium-doped sodium iodide [NaI(Tl)] detectors on an SBC at the Domestic Nuclear Detection Office's (DNDO) test track facility at the Port of Tacoma (PoT). These detectors were used to monitor background radiation levels and continuously recorded data during crane operations using a custom-built software package. Count rates and spectral data were recorded for various crane heights over both land and water. The results of this research created a background profile in which count rate was heavily dependent on position demonstrating how detector readings changed in the operational environment.
[The model of aged-hearing monitoring under the hospital information system].
Bao, Xiao-lin; Xu, Hua; Sun, Qiang; Liu, Ji-hong; Guo, Jia-liang
2013-03-01
To study the oldly people's hearing screening and dynamic monitoring mode, and to discuss the new diseases and health management mode in current information network era. To establish the network connection between the hospital and the communities in the internet through the function expansion of the Hospital Information Systems and to realize "dual systems, double platforms" integrated management modes and establish the audiology workstation. The routine physical examination, pure tone hearing threshold tests and middle ear analysis were performed on four hundred and twenty elderly people from the fourteen communities every three months, and the changes of hearing and related symptoms were observed. Resources sharing was established between the hospital and these fourteen communities. Health records were established for all the aged people, the hearing screening lasted only half a day each time. Fourteen hearing loss cases were found during one year. A statistically significant difference (P < 0.01) were found, the ratio of hearing loss with diabetes, high blood pressure and other diseases were much higher than people without concomitant. The advantage of disease management mode under the Hospital Information System is convenient, the work efficiency and qualities are improved, which is worthy of popularizing.
Implementation of Task-Tracking Software for Clinical IT Management.
Purohit, Anne-Maria; Brutscheck, Clemens; Prokosch, Hans-Ulrich; Ganslandt, Thomas; Schneider, Martin
2017-01-01
Often in clinical IT departments, many different methods and IT systems are used for task-tracking and project organization. Based on managers' personal preferences and knowledge about project management methods, tools differ from team to team and even from employee to employee. This causes communication problems, especially when tasks need to be done in cooperation with different teams. Monitoring tasks and resources becomes impossible: there are no defined deliverables, which prevents reliable deadlines. Because of these problems, we implemented task-tracking software which is now in use across all seven teams at the University Hospital Erlangen. Over a period of seven months, a working group defined types of tasks (project, routine task, etc.), workflows, and views to monitor the tasks of the 7 divisions, 20 teams and 340 different IT services. The software has been in use since December 2016.
An automated dose tracking system for adaptive radiation therapy.
Liu, Chang; Kim, Jinkoo; Kumarasiri, Akila; Mayyas, Essa; Brown, Stephen L; Wen, Ning; Siddiqui, Farzan; Chetty, Indrin J
2018-02-01
The implementation of adaptive radiation therapy (ART) into routine clinical practice is technically challenging and requires significant resources to perform and validate each process step. The objective of this report is to identify the key components of ART, to illustrate how a specific automated procedure improves efficiency, and to facilitate the routine clinical application of ART. Data was used from patient images, exported from a clinical database and converted to an intermediate format for point-wise dose tracking and accumulation. The process was automated using in-house developed software containing three modularized components: an ART engine, user interactive tools, and integration tools. The ART engine conducts computing tasks using the following modules: data importing, image pre-processing, dose mapping, dose accumulation, and reporting. In addition, custom graphical user interfaces (GUIs) were developed to allow user interaction with select processes such as deformable image registration (DIR). A commercial scripting application programming interface was used to incorporate automated dose calculation for application in routine treatment planning. Each module was considered an independent program, written in C++or C#, running in a distributed Windows environment, scheduled and monitored by integration tools. The automated tracking system was retrospectively evaluated for 20 patients with prostate cancer and 96 patients with head and neck cancer, under institutional review board (IRB) approval. In addition, the system was evaluated prospectively using 4 patients with head and neck cancer. Altogether 780 prostate dose fractions and 2586 head and neck cancer dose fractions went processed, including DIR and dose mapping. On average, daily cumulative dose was computed in 3 h and the manual work was limited to 13 min per case with approximately 10% of cases requiring an additional 10 min for image registration refinement. An efficient and convenient dose tracking system for ART in the clinical setting is presented. The software and automated processes were rigorously evaluated and validated using patient image datasets. Automation of the various procedures has improved efficiency significantly, allowing for the routine clinical application of ART for improving radiation therapy effectiveness. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Parish, David W.; Grabbe, Robert D.; Marzwell, Neville I.
1994-01-01
A Modular Autonomous Robotic System (MARS), consisting of a modular autonomous vehicle control system that can be retrofit on to any vehicle to convert it to autonomous control and support a modular payload for multiple applications is being developed. The MARS design is scalable, reconfigurable, and cost effective due to the use of modern open system architecture design methodologies, including serial control bus technology to simplify system wiring and enhance scalability. The design is augmented with modular, object oriented (C++) software implementing a hierarchy of five levels of control including teleoperated, continuous guidepath following, periodic guidepath following, absolute position autonomous navigation, and relative position autonomous navigation. The present effort is focused on producing a system that is commercially viable for routine autonomous patrolling of known, semistructured environments, like environmental monitoring of chemical and petroleum refineries, exterior physical security and surveillance, perimeter patrolling, and intrafacility transport applications.
Tullo, E; Fontana, I; Gottardo, D; Sloth, K H; Guarino, M
2016-09-01
Current farm sizes do not allow the precise identification and tracking of individual cows and their health and behavioral records. Currently, the application of information technology within intensive dairy farming takes a key role in proper routine management to improve animal welfare and to enhance the comfort of dairy cows. An existing application based on information technology is represented by the GEA CowView system (GEA Farm Technologies, Bönen, Germany). This system is able to detect and monitor animal behavioral activities based on positioning, through the creation of a virtual map of the barn that outlines all the areas where cows have access. The aim of this study was to validate the accuracy, sensitivity, and specificity of data provided by the CowView system. The validation was performed by comparing data automatically obtained from the CowView system with those obtained by a manual labeling procedure performed on video recordings. Data used for the comparisons were represented by the zone-related activities performed by the selected dairy cows and were classified into 2 categories: activity and localization. The duration in seconds of each of the activities/localizations detected both with the manual labeling and with the automated system were used to evaluate the correlation coefficients among data; and subsequently the accuracy, sensitivity, specificity, and positive and negative predictive values of the automated monitoring system were calculated. The results of this validation study showed that the CowView automated monitoring system is able to identify the cow localization/position (alley, trough, cubicles) with high reliability in relation to the zone-related activities performed by dairy cows (accuracy higher than 95%). The results obtained support the CowView system as an innovative potential solution for the easier management of dairy cows. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
76 FR 4435 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... entry, computer systems analysis and computer programming services. The contractors promptly return data.... Proposed Routine Use Disclosures of Data in the System This System of Records contains information such as... compatible use of data is known as a ``routine use''. The routine uses proposed for this System are...
Sagi, Moshe; Nesher, Lior; Yagupsky, Pablo
2017-03-01
The performance of the Bactec FX blood culture system for detecting Brucella bacteremia within the routine 1-week incubation period was assessed in a prospective study conducted in an area in southern Israel in which Brucella melitensis is endemic. Aerobic vials (BD Bactec Plus Aerobic/F medium) inoculated with blood specimens obtained from adult patients with positive Rose-Bengal screening test results were monitored for 4 consecutive weeks, and blind subcultures of negative vials were performed on solid media on days 7 and 28. During a 16-month period, a total of 31 (35.2%) of 88 cultures, obtained from 19 (38.0%) of 50 patients, were positive for Brucella melitensis The blood culture instrument identified 30 (96.8%) of 31 positive vials within 7 days of incubation; the single positive vial that was missed by the automated readings was detected only by the blind subculture performed on day 28. It is concluded that the Bactec FX system is able to detect the vast majority of episodes of Brucella bacteremia within the 1-week incubation protocol instituted in most clinical microbiology laboratories and without the need to perform blind subcultures of negative vials, enabling early diagnosis and saving labor and incubation time and space. Copyright © 2017 American Society for Microbiology.
[Evaluation of exercise capacity in pulmonary arterial hypertension].
Demir, Rengin; Küçükoğlu, Mehmet Serdar
2010-12-01
Pulmonary arterial hypertension (PAH) is a life-threatening disease characterized by increased pulmonary vascular resistance that leads to right ventricular failure. The most common clinical features of PAH are dyspnea and exercise intolerance. Measurement of exercise capacity is of considerable importance for the assessment of disease severity as well as routine monitoring of disease. Maximal, symptom-limited, cardiopulmonary exercise test (CPET) is the gold standard for the evaluation of exercise capacity, whereby functions of several systems involved in exercise can be assessed, including cardiovascular, respiratory, and metabolic systems. However, in order to derive the most useful diagnostic information on physiologic limitations to exercise, CPET requires maximal effort of the patient, which can be difficult and risky for some severely ill patients. Moreover, it requires specific exercise equipment and measurement systems, and experienced and trained personnel. Thus, routine clinical use of CPET to assess exercise capacity in patients with PAH may not always be feasible. A practical and simple alternative to CPET to determine exercise capacity is the 6-minute walk test (6MWT). It is simple to perform, safe, and reproducible. In contrast to CPET, the 6MWT reflects a submaximal level of exertion that is more consistent with the effort required for daily physical activities. This review focuses on the role of CPET and 6MWT in patients with PAH.
Crack Propagation Analysis Using Acoustic Emission Sensors for Structural Health Monitoring Systems
Kral, Zachary; Horn, Walter; Steck, James
2013-01-01
Aerospace systems are expected to remain in service well beyond their designed life. Consequently, maintenance is an important issue. A novel method of implementing artificial neural networks and acoustic emission sensors to form a structural health monitoring (SHM) system for aerospace inspection routines was the focus of this research. Simple structural elements, consisting of flat aluminum plates of AL 2024-T3, were subjected to increasing static tensile loading. As the loading increased, designed cracks extended in length, releasing strain waves in the process. Strain wave signals, measured by acoustic emission sensors, were further analyzed in post-processing by artificial neural networks (ANN).more » Several experiments were performed to determine the severity and location of the crack extensions in the structure. ANNs were trained on a portion of the data acquired by the sensors and the ANNs were then validated with the remaining data. The combination of a system of acoustic emission sensors, and an ANN could determine crack extension accurately. The difference between predicted and actual crack extensions was determined to be between 0.004 in. and 0.015 in. with 95% confidence. These ANNs, coupled with acoustic emission sensors, showed promise for the creation of an SHM system for aerospace systems.« less
Crack Propagation Analysis Using Acoustic Emission Sensors for Structural Health Monitoring Systems
Horn, Walter; Steck, James
2013-01-01
Aerospace systems are expected to remain in service well beyond their designed life. Consequently, maintenance is an important issue. A novel method of implementing artificial neural networks and acoustic emission sensors to form a structural health monitoring (SHM) system for aerospace inspection routines was the focus of this research. Simple structural elements, consisting of flat aluminum plates of AL 2024-T3, were subjected to increasing static tensile loading. As the loading increased, designed cracks extended in length, releasing strain waves in the process. Strain wave signals, measured by acoustic emission sensors, were further analyzed in post-processing by artificial neural networks (ANN). Several experiments were performed to determine the severity and location of the crack extensions in the structure. ANNs were trained on a portion of the data acquired by the sensors and the ANNs were then validated with the remaining data. The combination of a system of acoustic emission sensors, and an ANN could determine crack extension accurately. The difference between predicted and actual crack extensions was determined to be between 0.004 in. and 0.015 in. with 95% confidence. These ANNs, coupled with acoustic emission sensors, showed promise for the creation of an SHM system for aerospace systems. PMID:24023536
Borgatti, Antonella; Winter, Amber L; Stuebner, Kathleen; Scott, Ruth; Ober, Christopher P; Anderson, Kari L; Feeney, Daniel A; Vallera, Daniel A; Koopmeiners, Joseph S; Modiano, Jaime F; Froelich, Jerry
2017-01-01
Positron Emission Tomography-Computed Tomography (PET-CT) is routinely used for staging and monitoring of human cancer patients and is becoming increasingly available in veterinary medicine. In this study, 18-fluorodeoxyglucose (18FDG)-PET-CT was used in dogs with naturally occurring splenic hemangiosarcoma (HSA) to assess its utility as a staging and monitoring modality as compared to standard radiography and ultrasonography. Nine dogs with stage-2 HSA underwent 18FDG-PET-CT following splenectomy and prior to commencement of chemotherapy. Routine staging (thoracic radiography and abdominal ultrasonography) was performed prior to 18FDG-PET-CT in all dogs. When abnormalities not identified on routine tests were noted on 18FDG-PET-CT, owners were given the option to repeat a PET-CT following treatment with eBAT. A PET-CT scan was repeated on Day 21 in three dogs. Abnormalities not observed on conventional staging tools, and most consistent with malignant disease based on location, appearance, and outcome, were detected in two dogs and included a right atrial mass and a hepatic nodule, respectively. These lesions were larger and had higher metabolic activity on the second scans. 18FDG-PET-CT has potential to provide important prognostic information and influence treatment recommendations for dogs with stage-2 HSA. Additional studies will be needed to precisely define the value of this imaging tool for staging and therapy monitoring in dogs with this and other cancers.
Winter, Amber L.; Stuebner, Kathleen; Scott, Ruth; Ober, Christopher P.; Anderson, Kari L.; Feeney, Daniel A.; Vallera, Daniel A.; Koopmeiners, Joseph S.; Modiano, Jaime F.; Froelich, Jerry
2017-01-01
Positron Emission Tomography-Computed Tomography (PET-CT) is routinely used for staging and monitoring of human cancer patients and is becoming increasingly available in veterinary medicine. In this study, 18-fluorodeoxyglucose (18FDG)-PET-CT was used in dogs with naturally occurring splenic hemangiosarcoma (HSA) to assess its utility as a staging and monitoring modality as compared to standard radiography and ultrasonography. Nine dogs with stage-2 HSA underwent 18FDG-PET-CT following splenectomy and prior to commencement of chemotherapy. Routine staging (thoracic radiography and abdominal ultrasonography) was performed prior to 18FDG-PET-CT in all dogs. When abnormalities not identified on routine tests were noted on 18FDG-PET-CT, owners were given the option to repeat a PET-CT following treatment with eBAT. A PET-CT scan was repeated on Day 21 in three dogs. Abnormalities not observed on conventional staging tools, and most consistent with malignant disease based on location, appearance, and outcome, were detected in two dogs and included a right atrial mass and a hepatic nodule, respectively. These lesions were larger and had higher metabolic activity on the second scans. 18FDG-PET-CT has potential to provide important prognostic information and influence treatment recommendations for dogs with stage-2 HSA. Additional studies will be needed to precisely define the value of this imaging tool for staging and therapy monitoring in dogs with this and other cancers. PMID:28222142
Scantlebury, Arabella; Sheard, Laura; Watt, Ian; Cairns, Paul; Wright, John; Adamson, Joy
2017-01-07
To explore the benefits, barriers and disadvantages of implementing an electronic record system (ERS). The extent that the system has become 'normalised' into routine practice was also explored. Qualitative semi-structured interviews were conducted with 19 members of NHS staff who represented a variety of staff groups (doctors, midwives of different grades, health care assistants) and wards within a maternity unit at a NHS teaching hospital. Interviews were conducted during the first year of the phased implementation of ERS and were analysed thematically. The four mechanisms of Normalisation Process Theory (NPT) (coherence, cognitive participation, collective action and reflexive monitoring) were adapted for use within the study and provided a theoretical framework to interpret the study's findings. Coherence (participants' understanding of why the ERS has been implemented) was mixed - whilst those involved in ERS implementation anticipated advantages such as improved access to information; the majority were unclear why the ERS was introduced. Participants' willingness to engage with and invest time into the ERS (cognitive participation) depended on the amount of training and support they received and their willingness to change from paper to electronic records. Collective action (the extent the ERS was used) may be influenced by whether participants perceived there to be benefits associated with the system. Whilst some individuals reported benefits such as improved legibility of records, others felt benefits were yet to emerge. The parallel use of paper and the lack of integration of electronic systems within and between the trust and other healthcare organisations hindered ERS use. When appraising the ERS (reflexive monitoring) participants perceived the system to negatively impact the patient-clinician relationship, time and patient safety. Despite expectations that the ERS would have a number of advantages, its implementation was perceived to have a range of disadvantages and only a limited number of 'clinical benefits'. The study highlights the complexity of implementing electronic systems and the associated longevity before they can become 'embedded' into routine practice. Through the identification of barriers to the employment of electronic systems this process could be streamlined with the avoidance of any potential detriment to clinical services.
Idaho National Laboratory Cultural Resource Monitoring Report for 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, Julie B.
2013-10-01
This report describes the cultural resource monitoring activities of the Idaho National Laboratory’s (INL) Cultural Resource Management (CRM) Office during 2013. Throughout the year, thirty-eight cultural resource localities were revisited including: two locations with Native American human remains, one of which is also a cave; fourteen additional caves; seven prehistoric archaeological sites ; four historic archaeological sites; one historic trail; one nuclear resource (Experimental Breeder Reactor-I, a designated National Historic Landmark); and nine historic structures located at the Central Facilities Area. Of the monitored resources, thirty-three were routinely monitored, and five were monitored to assess project compliance with cultural resourcemore » recommendations along with the effects of ongoing project activities. On six occasions, ground disturbing activities within the boundaries of the Power Burst Facility/Critical Infrastructure Test Range Complex (PBF/CITRC) were observed by INL CRM staff prepared to respond to any additional finds of Native American human remains. In addition, two resources were visited more than once as part of the routine monitoring schedule or to monitor for additional damage. Throughout the year, most of the cultural resources monitored had no visual adverse changes resulting in Type 1determinations. However, Type 2 impacts were noted at eight sites, indicating that although impacts were noted or that a project was operating outside of culturally cleared limitations, cultural resources retained integrity and noted impacts did not threaten National Register eligibility. No new Type 3 or any Type 4 impacts that adversely impacted cultural resources and threatened National Register eligibility were observed at cultural resources monitored in 2013.« less
Monitoring O3 and Aerosols with the NASA LaRC Mobile Ozone Lidar System
NASA Technical Reports Server (NTRS)
Ganoe, Rene; Gronoff, Guillaume; Berkoff, Timothy; DeYoung, Russell; Carrion, William
2016-01-01
The NASA's Langley Mobile Ozone Lidar (LMOL) system routinely measures tropospheric ozone and aerosol profiles, and is part of the Tropospheric Lidar Network (TOLNet). Recent upgrades to the system include a new pump laser that has tripled the transmission output power extending measurements up to 8 km in altitude during the day. In addition, software and algorithm developments have improved data output quality and enabled a real-time ozone display capability. In 2016, a number of ozone features were captured by LMOL, including the dynamics of an early-season ozone exceedance that impacted the Hampton Roads region. In this presentation, we will review current LMOL capabilities, recent air quality events observed by the system, and show a comparison of aerosol retrieval through the UV channel and the green line channel.
Yao, Chunlei; Li, Qianqian; Guo, Jing; Yan, Feng; Hsing, I-Ming
2015-03-11
Rigid and flexible organic electrochemical transistor arrays are successfully implemented for monitoring cardiac action potentials. Excellent signal to noise ratios are achieved with values routinely larger than 4. These devices are promising to be used in both conventional and emerging areas. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Turbulence Environment Characterization
1979-06-01
of ro is consistent with the simultaneous measurement made with the Seeing Monitor. An average turbulent profile developed primarily from microthermal ...data. The operation of the routine meteorological instrumentation, microthermal probes, acoustic sounder, Seeing Monitor and Star Sensor have been...and J. Spencer of RADC gave sub- stantial support and assistance with the microthermal probes, acoustic sounder and PDP-8 software. We acknowledge R
Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2018-01-01
A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To overcome current knowledge deficits and methodological inconsistencies, future investigations should systematically evaluate the validity and usefulness of the various approaches available to guide and improve the implementation of decision-support systems in (team) sports practice.
Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander
2018-01-01
A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To overcome current knowledge deficits and methodological inconsistencies, future investigations should systematically evaluate the validity and usefulness of the various approaches available to guide and improve the implementation of decision-support systems in (team) sports practice. PMID:29904351
Event-based surveillance in north-western Ethiopia: experience and lessons learnt in the field
Ota, Masaki; Beyene, Belay Bezabih
2015-01-01
This study piloted an event-based surveillance system at the health centre (HC) level in Ethiopia. The system collects rumours in the community and registers them in rumour logbooks to record events of disease outbreaks and public health emergencies. Descriptive analysis was conducted on the events captured at the 59 study HCs in the Amhara Region in north-western Ethiopia between October 2013 and November 2014. A total of 126 rumours were registered at two thirds of the HCs during the study period. The average event reporting time was 3.8 days; response time of the HCs was 0.6 days, resulting in a total response time of 4.4 days. The most commonly reported rumours were measles-related (n = 90, 71%). These rumours followed a similar pattern of measles cases reported in the routine surveillance system. The largest proportion of rumours were reported by community members (n = 38, 36%) followed by health post workers (n = 36, 29%) who were normally informed by the community members about the rumours. This surveillance system was established along with an existing indicator-based surveillance system and was simple to implement. The implementation cost was minimal, requiring only printing and distribution of rumour logbooks to the HCs and brief orientations to focal persons. In countries where routine surveillance is still weak, an event-based surveillance system similar to this should be considered as a supplementary tool for disease monitoring. PMID:26668763
NASA Technical Reports Server (NTRS)
Calaway, Michael J.
2013-01-01
In preparation for OSIRIS-REx and other future sample return missions concerned with analyzing organics, we conducted an Organic Contamination Baseline Study for JSC Curation Labsoratories in FY12. For FY12 testing, organic baseline study focused only on molecular organic contamination in JSC curation gloveboxes: presumably future collections (i.e. Lunar, Mars, asteroid missions) would use isolation containment systems over only cleanrooms for primary sample storage. This decision was made due to limit historical data on curation gloveboxes, limited IR&D funds and Genesis routinely monitors organics in their ISO class 4 cleanrooms.
Transparent lattice characterization with gated turn-by-turn data of diagnostic bunch train
NASA Astrophysics Data System (ADS)
Li, Yongjun; Cheng, Weixing; Ha, Kiman; Rainer, Robert
2017-11-01
Methods of characterization of a storage ring's lattice have traditionally been intrusive to routine operations. More importantly, the lattice seen by particles can drift with the beam current due to collective effects. To circumvent this, we have developed a novel approach for dynamically characterizing a storage ring's lattice that is transparent to operations. Our approach adopts a dedicated filling pattern which has a short, separate diagnostic bunch train (DBT). Through the use of a bunch-by-bunch feedback system, the DBT can be selectively excited on demand. Gated functionality of a beam position monitor system is capable of collecting turn-by-turn data of the DBT, from which the lattice can then be characterized after excitation. As the DBT comprises only about one percent of the total operational bunches, the effects of its excitation are negligible to users. This approach allows us to localize the distributed quadrupolar wakefields generated in the storage ring vacuum chamber during beam accumulation. While effectively transparent to operations, our approach enables us to dynamically control the beta beat and phase beat, and unobtrusively optimize performance of the National Synchrotron Light Source-II accelerator during routine operations.
Transparent lattice characterization with gated turn-by-turn data of diagnostic bunch train
Li, Yongjun; Cheng, Weixing; Ha, Kiman; ...
2017-11-21
Methods of characterization of a storage ring's lattice have traditionally been intrusive to routine operations. More importantly, the lattice seen by particles can drift with the beam current due to collective effects. To circumvent this, we have developed a novel approach for dynamically characterizing a storage ring's lattice that is transparent to operations. Our approach adopts a dedicated filling pattern which has a short, separate Diagnostic Bunch-Train (DBT). Through the use of a bunch-by-bunch feedback system, the DBT can be selectively excited on-demand. Gated functionality of a beam position monitor system is capable of collecting turn-by-turn data of the DBT,more » from which the lattice can then be characterized after excitation. As the DBT comprises only about one percent of the total operational bunches, the effects of its excitation are negligible to users. Therefore, this approach allows us to localize the distributed quadrupolar wake fields generated in the storage ring vacuum chamber during beam accumulation. While effectively transparent to operations, our approach enables us to dynamically control the beta-beat and phase-beat, and unobtrusively optimize performance of National Synchrotron Light Source-II accelerator during routine operations.« less
Rapid determination of tartaric acid in wines.
Bastos, Sandra S T; Tafulo, Paula A R; Queirós, Raquel B; Matos, Cristina D; Sales, M Goreti F
2009-08-01
A flow-spectrophotometric method is proposed for the routine determination of tartaric acid in wines. The reaction between tartaric acid and vanadate in acetic media is carried out in flowing conditions and the subsequent colored complex is monitored at 475 nm. The stability of the complex and the corresponding formation constant are presented. The effect of wavelength and pH was evaluated by batch experiments. The selected conditions were transposed to a flow-injection analytical system. Optimization of several flow parameters such as reactor lengths, flow-rate and injection volume was carried out. Using optimized conditions, a linear behavior was observed up to 1000 microg mL(-1) tartaric acid, with a molar extinction coefficient of 450 L mg(-1) cm(-1) and +/- 1 % repeatability. Sample throughput was 25 samples per hour. The flow-spectrophotometric method was satisfactorily applied to the quantification of TA in wines from different sources. Its accuracy was confirmed by statistical comparison to the conventional Rebelein procedure and to a certified analytical method carried out in a routine laboratory.
Multitip scanning bio-Kelvin probe
NASA Astrophysics Data System (ADS)
Baikie, I. D.; Smith, P. J. S.; Porterfield, D. M.; Estrup, P. J.
1999-03-01
We have developed a novel multitip scanning Kelvin probe which can measure changes in biological surface potential ΔVs to within 2 mV and, quasisimultaneously monitor displacement to <1 μm. The control and measurement subcomponents are PC based and incorporate a flexible user interface permitting software control of each individual tip, measurement, and scan parameters. We review the mode of operation and design features of the scanning bio-Kelvin probe including tip steering, signal processing, tip calibration, and novel tip tracking/dithering routines. This system uniquely offers both tip-to-sample spacing control (which is essential to avoid spurious changes in ΔVs due to variations in mean spacing) and a dithering routine to maintain tip orientation to the biological specimen, irrespective of the latter's movement. These features permit long term (>48 h) "active" tracking of the displacement and biopotentials developed along and around a plant shoot in response to an environmental stimulus, e.g., differential illumination (phototropism) or changes in orientation (gravitropism).
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMaster, B.W.; Jones, S.B.; Sitzler, J.L.
1995-06-01
This document is a compendium of results of the calendar year 1994 Monitor Well Inspection and Maintenance Program at the Department of Energy Y-12 Plant in Oak Ridge, Tennessee. This report documents the work relating to well inspections and maintenance requests. Inspections are implemented in order to better assess the condition and maintenance needs of wells that are actively being monitored. Currently this approach calls for inspecting all wells on a routine (annual or triennial) basis which are: (1) in an active sampling program; (2) included in a hydrologic study; or (3) not in service, but not scheduled for pluggingmore » and abandonment. Routine inspections help to ensure that representative groundwater samples and hydrologic data are being collected, and contribute to the life expectancy of each well. This report formally presents well inspection and maintenance activities that were conducted at the Y-12 Plant during 1994. All inspections were conducted between April and December.« less
Bianchi, Anna Rita; Ferreri, Carla; Ruggiero, Simona; Deplano, Simone; Sunda, Valentina; Galloro, Giuseppe; Formisano, Cesare; Mennella, Maria Rosaria Faraone
2016-01-01
Establishing by statistical analyses whether the analyses of auto-modified poly(ADP-ribose)polymerase and erythrocyte membrane fatty acid composition (Fat Profile(®)), separately or in tandem, help monitoring the physio-pathology of the cell, and correlate with diseases, if present. Ninety five subjects were interviewed and analyzed blindly. Blood lymphocytes and erythrocytes were prepared to assay poly(ADP-ribose)polymerase automodification and fatty acid based membrane lipidome, respectively. Poly(ADP-ribose)polymerase automodification levels confirmed their correlation with DNA damage extent, and allowed monitoring disease activity, upon surgical/therapeutic treatment. Membrane lipidome profiles showed lipid unbalance mainly linked to inflammatory states. Statistically both tests were separately significant, and correlated each other within some pathologies. In the laboratory routine, both tests, separately or in tandem, might be a preliminary and helpful step to investigate the occurrence of a given disease. Their combination represents a promising integrated panel for sensible, noninvasive and routine health monitoring.
Discovering Activities to Recognize and Track in a Smart Environment
Rashidi, Parisa; Cook, Diane J.; Holder, Lawrence B.; Schmitter-Edgecombe, Maureen
2011-01-01
The machine learning and pervasive sensing technologies found in smart homes offer unprecedented opportunities for providing health monitoring and assistance to individuals experiencing difficulties living independently at home. In order to monitor the functional health of smart home residents, we need to design technologies that recognize and track activities that people normally perform as part of their daily routines. Although approaches do exist for recognizing activities, the approaches are applied to activities that have been pre-selected and for which labeled training data is available. In contrast, we introduce an automated approach to activity tracking that identifies frequent activities that naturally occur in an individual’s routine. With this capability we can then track the occurrence of regular activities to monitor functional health and to detect changes in an individual’s patterns and lifestyle. In this paper we describe our activity mining and tracking approach and validate our algorithms on data collected in physical smart environments. PMID:21617742
Masanja, Honorati; Schellenberg, Joanna Armstrong; Mshinda, Hassan M; Shekar, Meera; Mugyabuso, Joseph K L; Ndossi, Godwin D; de Savigny, Don
2006-11-01
Efficient delivery strategies for health interventions are essential for high and sustainable coverage. We report impact of a change in programmatic delivery strategy from routine delivery through the Expanded Programme on Immunization (EPI+) approach to twice-yearly mass distribution campaigns on coverage of vitamin A supplementation in Tanzania We investigated disparities in age, sex, socio-economic status, nutritional status and maternal education within vitamin A coverage in children between 1 and 2 years of age from two independent household level child health surveys conducted (1) during a continuous universal targeting scheme based on routine EPI contacts for children aged 9, 15 and 21 months (1999); and (2) three years later after the introduction of twice-yearly vitamin A supplementation campaigns for children aged 6 months to 5 years, a 6-monthly universal targeting scheme (2002). A representative cluster sample of approximately 2,400 rural households was obtained from Rufiji, Morogoro Rural, Kilombero and Ulanga districts. A modular questionnaire about the health of all children under the age of five was administered to consenting heads of households and caretakers of children. Information on the use of child health interventions including vitamin A was asked. Coverage of vitamin A supplementation among 1-2 year old children increased from 13% [95% CI 10-18%] in 1999 to 76% [95%CI 72-81%] in 2002. In 2002 knowledge of two or more child health danger signs was negatively associated with vitamin A supplementation coverage (80% versus 70%) (p = 0.04). Nevertheless, we did not find any disparities in coverage of vitamin A by district, gender, socio-economic status and DPT vaccinations. Change in programmatic delivery of vitamin A supplementation was associated with a major improvement in coverage in Tanzania that was been sustained by repeated campaigns for at least three years. There is a need to monitor the effect of such campaigns on the routine health system and on equity of coverage. Documentation of vitamin A supplementation campaign contacts on routine maternal and child health cards would be a simple step to facilitate this monitoring.
Evaluation of Miniature Wireless Vital Signs Monitor in a Trauma Intensive Care Unit.
Meizoso, Jonathan P; Allen, Casey J; Ray, Juliet J; Van Haren, Robert M; Teisch, Laura F; Baez, Xiomara Ruiz; Livingstone, Alan S; Namias, Nicholas; Schulman, Carl I; Proctor, Kenneth G
2016-05-01
A previous study demonstrated basic proof of principle of the value of a miniature wireless vital signs monitor (MWVSM, MiniMedic, Athena GTX, Des Moines, Iowa) for battlefield triage However, there were unanswered questions related to sensor reliability and uncontrolled conditions in the prehospital environment. This study determined whether MWVSM sensors track vital signs and allow for appropriate triage compared to a gold standard bedside monitor in trauma patients. This was a prospective study in 59 trauma intensive care unit patients. Systolic blood pressure, temperature, heart rate (HR), skin temperature, and pulse oximetry (SpO2) were displayed on a bedside monitor for 60 minutes. Shock index (SI) was calculated. A separate MWVSM monitor was attached to the forehead and finger of each patient. Data from each included pulse wave transit time (PWTT), temperature, HR, SpO2, and a summary status termed "Murphy Factor" (MF), which ranges from 0 to 5. Patients are classified as "routine" if MF = 0 to 1 or SI = 0 to 0.7, "priority" if MF = 2 to 3 or SI = 0.7 to 0.9, and "critical" if MF = 4 to 5 or SI ≥ 0.9. Forehead and finger MWVSM HRs both differed from the monitor (both p < 0.001), but the few beats per minute differences were clinically insignificant. Differences in MWVSM SpO2 (1-7%) and temperature (6-13°F) from the monitor were site specific (all p < 0.001). Forehead PWTT (271 ± 50 ms) was less (p < 0.001) than finger PWTT (315 ± 42 ms); both were dissociated from systolic blood pressure (r(2) < 0.05). The SI distributed patients about equally as "routine," "priority," and "critical," whereas MF overtriaged to "routine" and undertriaged to "critical" for both sensors (all p < 0.001). Our findings suggest that MF does not accurately predict the most critical patients, likely because erroneous PWTT values confound MF calculations. MF and the MWVSM are promising, but require fine-tuning before deployment. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Tips and traps in the 14C bio-AMS preparation laboratory
NASA Astrophysics Data System (ADS)
Buchholz, Bruce A.; Freeman, Stewart P. H. T.; Haack, Kurt W.; Vogel, John S.
2000-10-01
Maintaining a contamination free sample preparation lab for biological 14C AMS requires the same or more diligence as a radiocarbon dating prep lab. Isotope ratios of materials routinely range over 4-8 orders of magnitude in a single experiment, dosing solutions contain thousands of DPM and gels used to separate proteins possess 14C ratios of 1 amol 14C/mg C. Radiocarbon contamination is a legacy of earlier tracer work in most biological laboratories, even if they were never hot labs. Removable surface contamination can be found and monitored using swipes. Contamination can be found on any surface routinely touched: door knobs, light switches, drawer handles, water faucets. In general, all surfaces routinely touched need to be covered with paper, foil or plastic that can be changed frequently. Shared air supplies can also present problems by distributing hot aerosols throughout a building. Aerosols can be monitored for 14C content using graphitized coal or fullerene soot mixed with metal powder as an absorber. The monitors can be set out in work spaces for 1-2 weeks and measured by AMS with regular samples. Frequent air changes help minimize aerosol contamination in many cases. Cross-contamination of samples can be minimized by using disposable plastic or glassware in the prep lab, isolating samples from the air when possible and using positive displacement pipettors.
Computer keyboard interaction as an indicator of early Parkinson’s disease
Giancardo, L.; Sánchez-Ferro, A.; Arroyo-Gallego, T.; Butterworth, I.; Mendoza, C. S.; Montero, P.; Matarazzo, M.; Obeso, J. A.; Gray, M. L.; Estépar, R. San José
2016-01-01
Parkinson’s disease (PD) is a slowly progressing neurodegenerative disease with early manifestation of motor signs. Objective measurements of motor signs are of vital importance for diagnosing, monitoring and developing disease modifying therapies, particularly for the early stages of the disease when putative neuroprotective treatments could stop neurodegeneration. Current medical practice has limited tools to routinely monitor PD motor signs with enough frequency and without undue burden for patients and the healthcare system. In this paper, we present data indicating that the routine interaction with computer keyboards can be used to detect motor signs in the early stages of PD. We explore a solution that measures the key hold times (the time required to press and release a key) during the normal use of a computer without any change in hardware and converts it to a PD motor index. This is achieved by the automatic discovery of patterns in the time series of key hold times using an ensemble regression algorithm. This new approach discriminated early PD groups from controls with an AUC = 0.81 (n = 42/43; mean age = 59.0/60.1; women = 43%/60%;PD/controls). The performance was comparable or better than two other quantitative motor performance tests used clinically: alternating finger tapping (AUC = 0.75) and single key tapping (AUC = 0.61). PMID:27703257
Computer keyboard interaction as an indicator of early Parkinson’s disease
NASA Astrophysics Data System (ADS)
Giancardo, L.; Sánchez-Ferro, A.; Arroyo-Gallego, T.; Butterworth, I.; Mendoza, C. S.; Montero, P.; Matarazzo, M.; Obeso, J. A.; Gray, M. L.; Estépar, R. San José
2016-10-01
Parkinson’s disease (PD) is a slowly progressing neurodegenerative disease with early manifestation of motor signs. Objective measurements of motor signs are of vital importance for diagnosing, monitoring and developing disease modifying therapies, particularly for the early stages of the disease when putative neuroprotective treatments could stop neurodegeneration. Current medical practice has limited tools to routinely monitor PD motor signs with enough frequency and without undue burden for patients and the healthcare system. In this paper, we present data indicating that the routine interaction with computer keyboards can be used to detect motor signs in the early stages of PD. We explore a solution that measures the key hold times (the time required to press and release a key) during the normal use of a computer without any change in hardware and converts it to a PD motor index. This is achieved by the automatic discovery of patterns in the time series of key hold times using an ensemble regression algorithm. This new approach discriminated early PD groups from controls with an AUC = 0.81 (n = 42/43 mean age = 59.0/60.1 women = 43%/60%PD/controls). The performance was comparable or better than two other quantitative motor performance tests used clinically: alternating finger tapping (AUC = 0.75) and single key tapping (AUC = 0.61).
Computer keyboard interaction as an indicator of early Parkinson's disease.
Giancardo, L; Sánchez-Ferro, A; Arroyo-Gallego, T; Butterworth, I; Mendoza, C S; Montero, P; Matarazzo, M; Obeso, J A; Gray, M L; Estépar, R San José
2016-10-05
Parkinson's disease (PD) is a slowly progressing neurodegenerative disease with early manifestation of motor signs. Objective measurements of motor signs are of vital importance for diagnosing, monitoring and developing disease modifying therapies, particularly for the early stages of the disease when putative neuroprotective treatments could stop neurodegeneration. Current medical practice has limited tools to routinely monitor PD motor signs with enough frequency and without undue burden for patients and the healthcare system. In this paper, we present data indicating that the routine interaction with computer keyboards can be used to detect motor signs in the early stages of PD. We explore a solution that measures the key hold times (the time required to press and release a key) during the normal use of a computer without any change in hardware and converts it to a PD motor index. This is achieved by the automatic discovery of patterns in the time series of key hold times using an ensemble regression algorithm. This new approach discriminated early PD groups from controls with an AUC = 0.81 (n = 42/43; mean age = 59.0/60.1; women = 43%/60%;PD/controls). The performance was comparable or better than two other quantitative motor performance tests used clinically: alternating finger tapping (AUC = 0.75) and single key tapping (AUC = 0.61).
Liabsuetrakul, Tippawan; Prappre, Tagoon; Pairot, Pakamas; Oumudee, Nurlisa; Islam, Monir
2017-06-01
Surveillance systems are yet to be integrated with health information systems for improving the health of pregnant mothers and their newborns, particularly in developing countries. This study aimed to develop a web-based epidemiological surveillance system for maternal and newborn health with integration of action-oriented responses and automatic data analysis with results presentations and to assess the system acceptance by nurses and doctors involved in various hospitals in southern Thailand. Freeware software and scripting languages were used. The system can be run on different platforms, and it is accessible via various electronic devices. Automatic data analysis with results presentations in the forms of graphs, tables and maps was part of the system. A multi-level security system was incorporated into the program. Most doctors and nurses involved in the study felt the system was easy to use and useful. This system can be integrated into country routine reporting system for monitoring maternal and newborn health and survival.
Flux of Kilogram-sized Meteoroids from Lunar Impact Monitoring. Supplemental Movies
NASA Technical Reports Server (NTRS)
Suggs, Robert; Cooke, William; Suggs, Ron; McNamara, Heather; Swift, Wesley; Moser, Danielle; Diekmann, Anne
2008-01-01
These videos, and audio accompany the slide presentation "Flux of Kilogram-sized Meteoroids from Lunar Impact Monitoring." The slide presentation reviews the routine lunar impact monitoring that has harvested over 110 impacts in 2 years of observations using telescopes and low-light level video cameras. The night side of the lunar surface provides a large collecting area for detecting these impacts and allows estimation of the flux of meteoroids down to a limiting luminous energy.
Development of a Kinect-based exergaming system for motor rehabilitation in neurological disorders
NASA Astrophysics Data System (ADS)
Estepa, A.; Sponton Piriz, S.; Albornoz, E.; Martínez, C.
2016-04-01
The development of videogames for physical therapy, known as exergames, has gained much interest in the last years. In this work, a sytem for rehabilitation and clinical evaluation of neurological patients is presented. The Microsoft Kinect device is used to track the full body of patients, and three games were developed to exercise and assess different aspects of balance and gait rehabilitation. The system provides visual feedback by means of an avatar that follows the movements of the patients, and sound and visual stimuli for giving orders during the experience. Also, the system includes a database and management tools for further analysis and monitoring of therapies. The results obtained show, on the one side, a great reception and interest of patients to use the system. On the other side, the specialists considered very useful the data collected and the quantitative analysis provided by the system, which was then adopted for the clinical routine.
Fiber optic based multiprobe system for intraoperative monitoring of brain functions
NASA Astrophysics Data System (ADS)
Mayevsky, Avraham; Flamm, E. S.; Pennie, William; Chance, Britton
1991-05-01
Monitoring of brain functions during neurosurgical conditions have been made by various groups of investigators. Attempts were made to monitor EEG or evoked potentials, cerebral blood flow, mitochondrial redox state during various neurosurgical procedures. In order to monitor various functions of the brain we have developed a new multiprobe (MPA) assembly, based on fiber optic probes and ion selective electrodes, enabling the assessment of relative CBF, mitochondrial redox state (NADH fluorescence) and ion homeostasis in real-time, intraoperatively. The base features of the multiprobe assembly were described previously (A. Mayevsky, J. Appl. Physiol. 54, 740-748, 1983). The multiprobe holder (made of Delarin) contained a bundle of fibers transmitting light to and from the brain as well as 3 ion selective electrodes (K+%/, Ca(superscript 2+, Na+) combined with DC steady potential electrodes (Ag/AgCl). The common part of the light guide contained 2 groups of fibers. For the Laser Doppler flowmetry one input fiber and two output fibers were glued in a triangular shape and connected to the standard commercial plug of the Laser Doppler flowmeter. For the monitoring of NADH redox state 10 excitation and 10 emission fibers were randomly mixed between and around the fibers used for the Laser Doppler flowmetry. This configuration of the fibers enabled us to monitor CBF and NADH redox state from about the same tissue volume. The ion selective electrodes were connected to an Ag/AgCl electrode holders and the entire MPA was protected by a Plexiglass sleeve. Animal experiments were used for the verification of the methods and recording of typical responses to various pathological situations. The entire multiprobe assembly was sterilized by the standard gas sterilization routine and was checked for electrodes integrity and calibration inside the operation room 24 hours later. The MPA was located on the exposed human cortex using a micromanipulator and data collection started immediately after, using a micro computer based data acquisition system. After recording of baseline levels of CBF, NADH redox state and extracellular ion levels, the responses to CBF decrease (occlusions of a blood vessel) were recorded followed by the recovery period. A significant correlation between the CBF and NADH redox state changes was recorded. This approach enabled us to correlate this change in energy supply, to those of extracellular ion concentration. The preliminary results obtained suggest that the usage of the MPA in the operating room may have a significant contribution to the neurosurgeon as a routine diagnostic tool. It seems to us that a simplified MPA which will enable to monitor only the relative CBF, NADH redox state as well as extracellular K+ is more appropriate for future usage.
Garg, Uttam; Zhang, Yan Victoria
2016-01-01
Mass spectrometry (MS) has been used in research and specialized clinical laboratories for decades as a very powerful technology to identify and quantify compounds. In recent years, application of MS in routine clinical laboratories has increased significantly. This is mainly due to the ability of MS to provide very specific identification, high sensitivity, and simultaneous analysis of multiple analytes (>100). The coupling of tandem mass spectrometry with gas chromatography (GC) or liquid chromatography (LC) has enabled the rapid expansion of this technology. While applications of MS are used in many clinical areas, therapeutic drug monitoring, drugs of abuse, and clinical toxicology are still the primary focuses of the field. It is not uncommon to see mass spectrometry being used in routine clinical practices for those applications.
Efforts Toward an Early Warning Crop Monitor for Countries at Risk
NASA Astrophysics Data System (ADS)
Budde, M. E.; Verdin, J. P.; Barker, B.; Humber, M. L.; Becker-Reshef, I.; Justice, C. O.; Magadzire, T.; Galu, G.; Rodriguez, M.; Jayanthi, H.
2015-12-01
Assessing crop growing conditions is a crucial aspect of monitoring food security in the developing world. One of the core components of the Group on Earth Observations - Global Agricultural Monitoring (GEOGLAM) targets monitoring Countries at Risk (component 3). The Famine Early Warning Systems Network (FEWS NET) has a long history of utilizing remote sensing and crop modeling to address food security threats in the form of drought, floods, pest infestation, and climate change in some of the world's most at risk countries. FEWS NET scientists at the U.S. Geological Survey Earth Resources Observation and Science (EROS) Center and the University of Maryland Department of Geography have undertaken efforts to address component 3, by promoting the development of a collaborative Early Warning Crop Monitor (EWCM) that would specifically address Countries at Risk. A number of organizations utilize combinations of satellite earth observations, field campaigns, network partner inputs, and crop modeling techniques to monitor crop conditions throughout the world. Agencies such as the Food and Agriculture Organization of the United Nations (FAO), United Nations World Food Programme (WFP), and the European Commission's Joint Research Centre (JRC) provide agricultural monitoring information and reporting across a broad number of areas at risk and in many cases, organizations routinely report on the same countries. The latter offers an opportunity for collaboration on crop growing conditions among agencies. The reduction of uncertainty and achievement of consensus will help strengthen confidence in decisions to commit resources for mitigation of acute food insecurity and support for resilience and development programs. In addition, the development of a collaborative global EWCM will provide each of the partner agencies with the ability to quickly gather crop condition information for areas where they may not typically work or have access to local networks. Using a framework developed by GEOGLAM for monitoring crop conditions in support of the Agricultural Market Information System, we developed an EWCM system for countries at risk. We present the current status of that implementation and highlight achievements to date along with future plans to support the needs of the global agricultural monitoring community.
The impact of opioids on the endocrine system.
Katz, Nathaniel; Mazer, Norman A
2009-02-01
Opioids have been used for medicinal and analgesic purposes for centuries. However, their negative effects on the endocrine system, which have been known for some times, are barely discussed in modern medicine. Therefore, we conducted a systematic review of the impact of opioids on the endocrine system. A review of the English language literature on preclinical and clinical studies of any type on the influence of opioids on the endocrine system was conducted. Preliminary recommendations for monitoring and managing these problems were provided. Long-term opioid therapy for either addiction or chronic pain often induces hypogonadism owing to central suppression of hypothalamic secretion of gonadotropin-releasing hormone. Symptoms of opioid-induced hypogonadism include loss of libido, infertility, fatigue, depression, anxiety, loss of muscle strength and mass, osteoporosis, and compression fractures in both men and women; impotence in men; and menstrual irregularities and galactorrhea in women. In view of the increased use of opioids for chronic pain, it has become increasingly important to monitor patients taking opioids and manage endocrine complications. Therefore, patients on opioid therapy should be routinely screened for such symptoms and for laboratory abnormalities in sex hormones. Opioid-induced hypogonadism seems to be a common complication of therapeutic or illicit opioid use. Patients on long-term opioid therapy should be prospectively monitored, and in cases of opioid-induced hypogonadism, we recommend nonopioid pain management, opioid rotation, or sex hormone supplementation after careful consideration of the risks and benefits.
NASA Astrophysics Data System (ADS)
Holdsworth, David W.; Detombe, Sarah A.; Chiodo, Chris; Fricke, Stanley T.; Drangova, Maria
2011-03-01
Advances in laboratory imaging systems for CT, SPECT, MRI, and PET facilitate routine micro-imaging during pre-clinical investigations. Challenges still arise when dealing with immune-compromised animals, biohazardous agents, and multi-modality imaging. These challenges can be overcome with an appropriate animal management system (AMS), with the capability for supporting and monitoring a rat or mouse during micro-imaging. We report the implementation and assessment of a new AMS system for mice (PRA-3000 / AHS-2750, ASI Instruments, Warren MI), designed to be compatible with a commercial micro-CT / micro-SPECT imaging system (eXplore speCZT, GE Healthcare, London ON). The AMS was assessed under the following criteria: 1) compatibility with the imaging system (i.e. artifact generation, geometric dimensions); 2) compatibility with live animals (i.e. positioning, temperature regulation, anesthetic supply); 3) monitoring capabilities (i.e. rectal temperature, respiratory and cardiac monitoring); 4) stability of co-registration; and 5) containment. Micro-CT scans performed using a standardized live-animal protocol (90 kVp, 40 mA, 900 views, 16 ms per view) exhibited low noise (+/-19 HU) and acceptable artifact from high-density components within the AMS (e.g. ECG pad contacts). Live mice were imaged repeatedly (with removal and replacement of the AMS) and spatial registration was found to be stable to within +/-0.07 mm. All animals tolerated enclosure within the AMS for extended periods (i.e. > one hour) without distress, based on continuous recordings of rectal temperature, ECG waveform and respiratory rate. A sealed AMS system extends the capability of a conventional micro-imaging system to include immune-compromised and biosafety level 2 mouse-imaging protocols.
Tunca, Can; Alemdar, Hande; Ertan, Halil; Incel, Ozlem Durmaz; Ersoy, Cem
2014-01-01
Human activity recognition and behavior monitoring in a home setting using wireless sensor networks (WSNs) provide a great potential for ambient assisted living (AAL) applications, ranging from health and wellbeing monitoring to resource consumption monitoring. However, due to the limitations of the sensor devices, challenges in wireless communication and the challenges in processing large amounts of sensor data in order to recognize complex human activities, WSN-based AAL systems are not effectively integrated in the home environment. Additionally, given the variety of sensor types and activities, selecting the most suitable set of sensors in the deployment is an important task. In order to investigate and propose solutions to such challenges, we introduce a WSN-based multimodal AAL system compatible for homes with multiple residents. Particularly, we focus on the details of the system architecture, including the challenges of sensor selection, deployment, networking and data collection and provide guidelines for the design and deployment of an effective AAL system. We also present the details of the field study we conducted, using the systems deployed in two different real home environments with multiple residents. With these systems, we are able to collect ambient sensor data from multiple homes. This data can be used to assess the wellbeing of the residents and identify deviations from everyday routines, which may be indicators of health problems. Finally, in order to elaborate on the possible applications of the proposed AAL system and to exemplify directions for processing the collected data, we provide the results of several human activity inference experiments, along with examples on how such results could be interpreted. We believe that the experiences shared in this work will contribute towards accelerating the acceptance of WSN-based AAL systems in the home setting. PMID:24887044
Tunca, Can; Alemdar, Hande; Ertan, Halil; Incel, Ozlem Durmaz; Ersoy, Cem
2014-05-30
Human activity recognition and behavior monitoring in a home setting using wireless sensor networks (WSNs) provide a great potential for ambient assisted living (AAL) applications, ranging from health and wellbeing monitoring to resource consumption monitoring. However, due to the limitations of the sensor devices, challenges in wireless communication and the challenges in processing large amounts of sensor data in order to recognize complex human activities, WSN-based AAL systems are not effectively integrated in the home environment. Additionally, given the variety of sensor types and activities, selecting the most suitable set of sensors in the deployment is an important task. In order to investigate and propose solutions to such challenges, we introduce a WSN-based multimodal AAL system compatible for homes with multiple residents. Particularly, we focus on the details of the system architecture, including the challenges of sensor selection, deployment, networking and data collection and provide guidelines for the design and deployment of an effective AAL system. We also present the details of the field study we conducted, using the systems deployed in two different real home environments with multiple residents. With these systems, we are able to collect ambient sensor data from multiple homes. This data can be used to assess the wellbeing of the residents and identify deviations from everyday routines, which may be indicators of health problems. Finally, in order to elaborate on the possible applications of the proposed AAL system and to exemplify directions for processing the collected data, we provide the results of several human activity inference experiments, along with examples on how such results could be interpreted. We believe that the experiences shared in this work will contribute towards accelerating the acceptance of WSN-based AAL systems in the home setting.
Environmental Management System Objectives & Targets Results Summary - FY 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vetter, Douglas W.
2016-02-01
Sandia National Laboratories (SNL) Environmental Management System is the integrated approach for members of the workforce to identify and manage environmental risks. Each Fiscal Year (FY) SNL performs an analysis to identify environmental aspects, and the environmental programs associated with them are charged with the task of routinely monitoring and measuring the objectives and targets that are established to mitigate potential impacts of SNL's operations on the environment. An annual summary of the results achieved towards meeting established Sandia Corporation and SNL Site-specific objectives and targets provides a connection to, and rational for, annually revised environmental aspects. The purpose ofmore » this document is to summarize the results achieved and documented in FY 2015.« less
Fluorescence detection of organic molecules in the Jovian atmosphere
NASA Technical Reports Server (NTRS)
Levine, J. S.; Rogowski, R. S.
1975-01-01
A search for fluorescent emission due to the presence of possible organic molecules in the Jovian atmosphere is described. We first consider natural Jovian fluorescent emission excited by precipitating auroral particles. Due to our lack of knowledge of the Jovian precipitating particle energies and fluxes we next consider fluorescent emission excited by a laser system aboard a Jupiter spacecraft. Laser-induced fluorescence is routinely used to monitor trace constituents and pollutants in the terrestrial atmosphere. Several spacecraft laser systems are currently under development. Our calculations indicate that laser-induced fluorescent detection is approximately two orders of magnitude more sensitive than rocket ultraviolet measurements of possible Jovian absorption features at 2600 A that have been attributed to the presence of adenine or benzene.
NASA Technical Reports Server (NTRS)
1977-01-01
Samples of liquid oxygen, high pressure nitrogen, low pressure nitrogen, and missile grade air were studied to determine the hydrocarbon concentrations. Concentration of the samples was achieved by adsorption on a molecular sieve and activated charcoal. The trapped hydrocarbons were then desorbed and transferred to an analytical column in a gas chromatograph. The sensitivity of the method depends on the volume of gas passed through the adsorbent tubes. The value of the method was verified through recoverability and reproducibility studies. The use of this method enables LOX, GN2, and missile grade air systems to be routinely monitored to determine low level increases in specific hydrocarbon concentration that could lead to potentially hazardous conditions.
Pichler, Peter; Mazanek, Michael; Dusberger, Frederico; Weilnböck, Lisa; Huber, Christian G; Stingl, Christoph; Luider, Theo M; Straube, Werner L; Köcher, Thomas; Mechtler, Karl
2012-11-02
While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC-MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge.
A MODIS-based automated flood monitoring system for southeast asia
NASA Astrophysics Data System (ADS)
Ahamed, A.; Bolten, J. D.
2017-09-01
Flood disasters in Southeast Asia result in significant loss of life and economic damage. Remote sensing information systems designed to spatially and temporally monitor floods can help governments and international agencies formulate effective disaster response strategies during a flood and ultimately alleviate impacts to population, infrastructure, and agriculture. Recent destructive flood events in the Lower Mekong River Basin occurred in 2000, 2011, 2013, and 2016 (http://ffw.mrcmekong.org/historical_rec.htm, April 24, 2017). The large spatial distribution of flooded areas and lack of proper gauge data in the region makes accurate monitoring and assessment of impacts of floods difficult. Here, we discuss the utility of applying satellite-based Earth observations for improving flood inundation monitoring over the flood-prone Lower Mekong River Basin. We present a methodology for determining near real-time surface water extent associated with current and historic flood events by training surface water classifiers from 8-day, 250-m Moderate-resolution Imaging Spectroradiometer (MODIS) data spanning the length of the MODIS satellite record. The Normalized Difference Vegetation Index (NDVI) signature of permanent water bodies (MOD44W; Carroll et al., 2009) is used to train surface water classifiers which are applied to a time period of interest. From this, an operational nowcast flood detection component is produced using twice daily imagery acquired at 3-h latency which performs image compositing routines to minimize cloud cover. Case studies and accuracy assessments against radar-based observations for historic flood events are presented. The customizable system has been transferred to regional organizations and near real-time derived surface water products are made available through a web interface platform. Results highlight the potential of near real-time observation and impact assessment systems to serve as effective decision support tools for governments, international agencies, and disaster responders.
2012-01-01
While the performance of liquid chromatography (LC) and mass spectrometry (MS) instrumentation continues to increase, applications such as analyses of complete or near-complete proteomes and quantitative studies require constant and optimal system performance. For this reason, research laboratories and core facilities alike are recommended to implement quality control (QC) measures as part of their routine workflows. Many laboratories perform sporadic quality control checks. However, successive and systematic longitudinal monitoring of system performance would be facilitated by dedicated automatic or semiautomatic software solutions that aid an effortless analysis and display of QC metrics over time. We present the software package SIMPATIQCO (SIMPle AuTomatIc Quality COntrol) designed for evaluation of data from LTQ Orbitrap, Q-Exactive, LTQ FT, and LTQ instruments. A centralized SIMPATIQCO server can process QC data from multiple instruments. The software calculates QC metrics supervising every step of data acquisition from LC and electrospray to MS. For each QC metric the software learns the range indicating adequate system performance from the uploaded data using robust statistics. Results are stored in a database and can be displayed in a comfortable manner from any computer in the laboratory via a web browser. QC data can be monitored for individual LC runs as well as plotted over time. SIMPATIQCO thus assists the longitudinal monitoring of important QC metrics such as peptide elution times, peak widths, intensities, total ion current (TIC) as well as sensitivity, and overall LC–MS system performance; in this way the software also helps identify potential problems. The SIMPATIQCO software package is available free of charge. PMID:23088386
Gagne, Joshua J; Wang, Shirley V; Rassen, Jeremy A; Schneeweiss, Sebastian
2014-06-01
The aim of this study was to develop and test a semi-automated process for conducting routine active safety monitoring for new drugs in a network of electronic healthcare databases. We built a modular program that semi-automatically performs cohort identification, confounding adjustment, diagnostic checks, aggregation and effect estimation across multiple databases, and application of a sequential alerting algorithm. During beta-testing, we applied the system to five databases to evaluate nine examples emulating prospective monitoring with retrospective data (five pairs for which we expected signals, two negative controls, and two examples for which it was uncertain whether a signal would be expected): cerivastatin versus atorvastatin and rhabdomyolysis; paroxetine versus tricyclic antidepressants and gastrointestinal bleed; lisinopril versus angiotensin receptor blockers and angioedema; ciprofloxacin versus macrolide antibiotics and Achilles tendon rupture; rofecoxib versus non-selective non-steroidal anti-inflammatory drugs (ns-NSAIDs) and myocardial infarction; telithromycin versus azithromycin and hepatotoxicity; rosuvastatin versus atorvastatin and diabetes and rhabdomyolysis; and celecoxib versus ns-NSAIDs and myocardial infarction. We describe the program, the necessary inputs, and the assumed data environment. In beta-testing, the system generated four alerts, all among positive control examples (i.e., lisinopril and angioedema; rofecoxib and myocardial infarction; ciprofloxacin and tendon rupture; and cerivastatin and rhabdomyolysis). Sequential effect estimates for each example were consistent in direction and magnitude with existing literature. Beta-testing across nine drug-outcome examples demonstrated the feasibility of the proposed semi-automated prospective monitoring approach. In retrospective assessments, the system identified an increased risk of myocardial infarction with rofecoxib and an increased risk of rhabdomyolysis with cerivastatin years before these drugs were withdrawn from the market. Copyright © 2014 John Wiley & Sons, Ltd.
Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.
Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan
2017-05-15
Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1μl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R 2 =0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.
Real-Time Monitoring of Psychotherapeutic Processes: Concept and Compliance
Schiepek, Günter; Aichhorn, Wolfgang; Gruber, Martin; Strunk, Guido; Bachler, Egon; Aas, Benjamin
2016-01-01
Objective: The feasibility of a high-frequency real-time monitoring approach to psychotherapy is outlined and tested for patients' compliance to evaluate its integration to everyday practice. Criteria concern the ecological momentary assessment, the assessment of therapy-related cognitions and emotions, equidistant time sampling, real-time nonlinear time series analysis, continuous participative process control by client and therapist, and the application of idiographic (person-specific) surveys. Methods: The process-outcome monitoring is technically realized by an internet-based device for data collection and data analysis, the Synergetic Navigation System. Its feasibility is documented by a compliance study on 151 clients treated in an inpatient and a day-treatment clinic. Results: We found high compliance rates (mean: 78.3%, median: 89.4%) amongst the respondents, independent of the severity of symptoms or the degree of impairment. Compared to other diagnoses, the compliance rate was lower in the group diagnosed with personality disorders. Conclusion: The results support the feasibility of high-frequency monitoring in routine psychotherapy settings. Daily collection of psychological surveys allows for the assessment of highly resolved, equidistant time series data which gives insight into the nonlinear qualities of therapeutic change processes (e.g., pattern transitions, critical instabilities). PMID:27199837
Engineering and Design: Structural Deformation Surveying
2002-06-01
loading deformations. Long-term measurements are far more common and somewhat more complex given their external nature . Long-term monitoring of a...fitting of structural elements, environmental protection, and development of mitigative measures in the case of natural disasters (land slides, earthquakes...of additional localized monitoring points (i.e., points not intended for routine observation) to determine the nature and extent of large displacements
9 CFR 146.33 - Terminology and classification; meat-type chicken slaughter plants.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Influenza Monitored. This program is intended to be the basis from which the meat-type chicken industry may conduct a program to monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of the H5/H7 subtypes of avian influenza in meat-type chickens through routine surveillance of...
9 CFR 146.43 - Terminology and classification; meat-type turkey slaughter plants.
Code of Federal Regulations, 2011 CFR
2011-01-01
... corresponding designs illustrated in § 146.9 of this part: (a) U.S. H5/H7 Avian Influenza Monitored. This... monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of avian influenza in meat-type turkeys through routine surveillance of each participating meat-type turkey slaughter...
9 CFR 146.33 - Terminology and classification; meat-type chicken slaughter plants.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Influenza Monitored. This program is intended to be the basis from which the meat-type chicken industry may conduct a program to monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of the H5/H7 subtypes of avian influenza in meat-type chickens through routine surveillance of...
9 CFR 146.43 - Terminology and classification; meat-type turkey slaughter plants.
Code of Federal Regulations, 2012 CFR
2012-01-01
... corresponding designs illustrated in § 146.9 of this part: (a) U.S. H5/H7 Avian Influenza Monitored. This... monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of avian influenza in meat-type turkeys through routine surveillance of each participating meat-type turkey slaughter...
9 CFR 146.43 - Terminology and classification; meat-type turkey slaughter plants.
Code of Federal Regulations, 2013 CFR
2013-01-01
... corresponding designs illustrated in § 146.9 of this part: (a) U.S. H5/H7 Avian Influenza Monitored. This... monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of avian influenza in meat-type turkeys through routine surveillance of each participating meat-type turkey slaughter...
9 CFR 146.33 - Terminology and classification; meat-type chicken slaughter plants.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Influenza Monitored. This program is intended to be the basis from which the meat-type chicken industry may conduct a program to monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of the H5/H7 subtypes of avian influenza in meat-type chickens through routine surveillance of...
9 CFR 146.33 - Terminology and classification; meat-type chicken slaughter plants.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Influenza Monitored. This program is intended to be the basis from which the meat-type chicken industry may conduct a program to monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of the H5/H7 subtypes of avian influenza in meat-type chickens through routine surveillance of...
9 CFR 146.43 - Terminology and classification; meat-type turkey slaughter plants.
Code of Federal Regulations, 2014 CFR
2014-01-01
... corresponding designs illustrated in § 146.9 of this part: (a) U.S. H5/H7 Avian Influenza Monitored. This... monitor for the H5/H7 subtypes of avian influenza. It is intended to determine the presence of avian influenza in meat-type turkeys through routine surveillance of each participating meat-type turkey slaughter...
Linking databases on perinatal health: a review of the literature and current practices in Europe
Szamotulska, K.; Hindori-Mohangoo, A.D.; Blondel, B.; Macfarlane, A.J.; Dattani, N.; Barona, C.; Berrut, S.; Zile, I.; Wood, R.; Sakkeus, L.; Gissler, M.; Zeitlin, J.
2016-01-01
Background: International comparisons of perinatal health indicators are complicated by the heterogeneity of data sources on pregnancy, maternal and neonatal outcomes. Record linkage can extend the range of data items available and thus can improve the validity and quality of routine data. We sought to assess the extent to which data are linked routinely for perinatal health research and reporting. Methods: We conducted a systematic review of the literature by searching PubMed for perinatal health studies from 2001 to 2011 based on linkage of routine data (data collected continuously at various time intervals). We also surveyed European health monitoring professionals about use of linkage for national perinatal health surveillance. Results: 516 studies fit our inclusion criteria. Denmark, Finland, Norway and Sweden, the US and the UK contributed 76% of the publications; a further 29 countries contributed at least one publication. Most studies linked vital statistics, hospital records, medical birth registries and cohort data. Other sources were specific registers for: cancer (70), congenital anomalies (56), ART (19), census (19), health professionals (37), insurance (22) prescription (31), and level of education (18). Eighteen of 29 countries (62%) reported linking data for routine perinatal health monitoring. Conclusion: Research using linkage is concentrated in a few countries and is not widely practiced in Europe. Broader adoption of data linkage could yield substantial gains for perinatal health research and surveillance. PMID:26891058
Therapeutic drug monitoring of antimetabolic cytotoxic drugs
Lennard, L
1999-01-01
Therapeutic drug monitoring is not routinely used for cytotoxic agents. There are several reasons, but one major drawback is the lack of established therapeutic concentration ranges. Combination chemotherapy makes the establishment of therapeutic ranges for individual drugs difficult, the concentration-effect relationship for a single drug may not be the same as that when the drug is used in a drug combination. Pharmacokinetic optimization protocols for many classes of cytotoxic compounds exist in specialized centres, and some of these protocols are now part of large multicentre trials. Nonetheless, methotrexate is the only agent which is routinely monitored in most treatment centres. An additional factor, especially in antimetabolite therapy, is the existence of pharmacogenetic enzymes which play a major role in drug metabolism. Monitoring of therapy could include assay of phenotypic enzyme activities or genotype in addition to, or instead of, the more traditional measurement of parent drug or drug metabolites. The cytotoxic activities of mercaptopurine and fluorouracil are regulated by thiopurine methyltransferase (TPMT) and dihydropyrimidine dehydrogenase (DPD), respectively. Lack of TPMT functional activity produces life-threatening mercaptopurine myelotoxicity. Very low DPD activity reduces fluorouracil breakdown producing severe cytotoxicity. These pharmacogenetic enzymes can influence the bioavailability, pharmacokinetics, toxicity and efficacy of their substrate drugs. PMID:10190647
NASA Astrophysics Data System (ADS)
Lee, Shiann-Jong; Liang, Wen-Tzong; Cheng, Hui-Wen; Tu, Feng-Shan; Ma, Kuo-Fong; Tsuruoka, Hiroshi; Kawakatsu, Hitoshi; Huang, Bor-Shouh; Liu, Chun-Chi
2014-01-01
We have developed a real-time moment tensor monitoring system (RMT) which takes advantage of a grid-based moment tensor inversion technique and real-time broad-band seismic recordings to automatically monitor earthquake activities in the vicinity of Taiwan. The centroid moment tensor (CMT) inversion technique and a grid search scheme are applied to obtain the information of earthquake source parameters, including the event origin time, hypocentral location, moment magnitude and focal mechanism. All of these source parameters can be determined simultaneously within 117 s after the occurrence of an earthquake. The monitoring area involves the entire Taiwan Island and the offshore region, which covers the area of 119.3°E to 123.0°E and 21.0°N to 26.0°N, with a depth from 6 to 136 km. A 3-D grid system is implemented in the monitoring area with a uniform horizontal interval of 0.1° and a vertical interval of 10 km. The inversion procedure is based on a 1-D Green's function database calculated by the frequency-wavenumber (fk) method. We compare our results with the Central Weather Bureau (CWB) catalogue data for earthquakes occurred between 2010 and 2012. The average differences between event origin time and hypocentral location are less than 2 s and 10 km, respectively. The focal mechanisms determined by RMT are also comparable with the Broadband Array in Taiwan for Seismology (BATS) CMT solutions. These results indicate that the RMT system is realizable and efficient to monitor local seismic activities. In addition, the time needed to obtain all the point source parameters is reduced substantially compared to routine earthquake reports. By connecting RMT with a real-time online earthquake simulation (ROS) system, all the source parameters will be forwarded to the ROS to make the real-time earthquake simulation feasible. The RMT has operated offline (2010-2011) and online (since January 2012 to present) at the Institute of Earth Sciences (IES), Academia Sinica (http://rmt.earth.sinica.edu.tw). The long-term goal of this system is to provide real-time source information for rapid seismic hazard assessment during large earthquakes.
Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard
NASA Astrophysics Data System (ADS)
Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly
2017-08-01
The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period
Performance of a completely automated system for monitoring CMV DNA in plasma.
Mengelle, C; Sandres-Sauné, K; Mansuy, J-M; Haslé, C; Boineau, J; Izopet, J
2016-06-01
Completely automated systems for monitoring CMV-DNA in plasma samples are now available. Evaluate analytical and clinical performances of the VERIS™/MDx System CMV Assay(®). Analytical performance was assessed using quantified quality controls. Clinical performance was assessed by comparison with the COBAS(®) Ampliprep™/COBAS(®) Taqman CMV test using 169 plasma samples that had tested positive with the in-house technique in whole blood. The specificity of the VERIS™/MDx System CMV Assay(®) was 99% [CI 95%: 97.7-100]. Intra-assay reproducibilities were 0.03, 0.04, 0.05 and 0.04 log10IU/ml (means 2.78, 3.70, 4.64 and 5.60 log10IU/ml) for expected values of 2.70, 3.70, 4.70 and 5.70 log10IU/ml. The inter-assay reproducibilities were 0.12 and 0.08 (means 6.30 and 2.85 log10IU/ml) for expected values of 6.28 and 2.80 log10IU/ml. The lower limit of detection was 14.6IU/ml, and the assay was linear from 2.34 to 5.58 log10IU/ml. The results for the positive samples were concordant (r=0.71, p<0.0001; slope of Deming regression 0.79 [CI 95%: 0.56-1.57] and y-intercept 0.79 [CI 95%: 0.63-0.95]). The VERIS™/MDx System CMV Assay(®) detected 18 more positive samples than did the COBAS(®) Ampliprep™/COBAS(®) Taqman CMV test and the mean virus load were higher (0.41 log10IU/ml). Patient monitoring on 68 samples collected from 17 immunosuppressed patients showed similar trends between the two assays. As secondary question, virus loads detected by the VERIS™/MDx System CMV Assay(®) were compared to those of the in-house procedure on whole blood. The results were similar between the two assays (-0.09 log10IU/ml) as were the patient monitoring trends. The performances of the VERIS™/MDx System CMV Assay(®) facilitated its routine use in monitoring CMV-DNA loads in plasma samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Direct and Absolute Quantification of over 1800 Yeast Proteins via Selected Reaction Monitoring*
Lawless, Craig; Holman, Stephen W.; Brownridge, Philip; Lanthaler, Karin; Harman, Victoria M.; Watkins, Rachel; Hammond, Dean E.; Miller, Rebecca L.; Sims, Paul F. G.; Grant, Christopher M.; Eyers, Claire E.; Beynon, Robert J.
2016-01-01
Defining intracellular protein concentration is critical in molecular systems biology. Although strategies for determining relative protein changes are available, defining robust absolute values in copies per cell has proven significantly more challenging. Here we present a reference data set quantifying over 1800 Saccharomyces cerevisiae proteins by direct means using protein-specific stable-isotope labeled internal standards and selected reaction monitoring (SRM) mass spectrometry, far exceeding any previous study. This was achieved by careful design of over 100 QconCAT recombinant proteins as standards, defining 1167 proteins in terms of copies per cell and upper limits on a further 668, with robust CVs routinely less than 20%. The selected reaction monitoring-derived proteome is compared with existing quantitative data sets, highlighting the disparities between methodologies. Coupled with a quantification of the transcriptome by RNA-seq taken from the same cells, these data support revised estimates of several fundamental molecular parameters: a total protein count of ∼100 million molecules-per-cell, a median of ∼1000 proteins-per-transcript, and a linear model of protein translation explaining 70% of the variance in translation rate. This work contributes a “gold-standard” reference yeast proteome (including 532 values based on high quality, dual peptide quantification) that can be widely used in systems models and for other comparative studies. PMID:26750110
Covian, Raul; Chess, David; Balaban, Robert S.
2012-01-01
Native gel electrophoresis allows the separation of very small amounts of protein complexes while retaining aspects of their activity. In-gel enzymatic assays are usually performed by using reaction-dependent deposition of chromophores or light scattering precipitates quantified at fixed time points after gel removal and fixation, limiting the ability to analyze enzyme reaction kinetics. Herein, we describe a custom reaction chamber with reaction media recirculation and filtering and an imaging system that permits the continuous monitoring of in-gel enzymatic activity even in the presence of turbidity. Images were continuously collected using time-lapse high resolution digital imaging, and processing routines were developed to obtain kinetic traces of the in-gel activities and analyze reaction time courses. This system also permitted the evaluation of enzymatic activity topology within the protein bands of the gel. This approach was used to analyze the reaction kinetics of two mitochondrial complexes in native gels. Complex IV kinetics showed a short initial linear phase where catalytic rates could be calculated, whereas Complex V activity revealed a significant lag phase followed by two linear phases. The utility of monitoring the entire kinetic behavior of these reactions in native gels, as well as the general application of this approach, is discussed. PMID:22975200
Laboratory and field based evaluation of chromatography ...
The Monitor for AeRosols and GAses in ambient air (MARGA) is an on-line ion-chromatography-based instrument designed for speciation of the inorganic gas and aerosol ammonium-nitrate-sulfate system. Previous work to characterize the performance of the MARGA has been primarily based on field comparison to other measurement methods to evaluate accuracy. While such studies are useful, the underlying reasons for disagreement among methods are not always clear. This study examines aspects of MARGA accuracy and precision specifically related to automated chromatography analysis. Using laboratory standards, analytical accuracy, precision, and method detection limits derived from the MARGA chromatography software are compared to an alternative software package (Chromeleon, Thermo Scientific Dionex). Field measurements are used to further evaluate instrument performance, including the MARGA’s use of an internal LiBr standard to control accuracy. Using gas/aerosol ratios and aerosol neutralization state as a case study, the impact of chromatography on measurement error is assessed. The new generation of on-line chromatography-based gas and particle measurement systems have many advantages, including simultaneous analysis of multiple pollutants. The Monitor for Aerosols and Gases in Ambient Air (MARGA) is such an instrument that is used in North America, Europe, and Asia for atmospheric process studies as well as routine monitoring. While the instrument has been evaluat
Covian, Raul; Chess, David; Balaban, Robert S
2012-12-01
Native gel electrophoresis allows the separation of very small amounts of protein complexes while retaining aspects of their activity. In-gel enzymatic assays are usually performed by using reaction-dependent deposition of chromophores or light-scattering precipitates quantified at fixed time points after gel removal and fixation, limiting the ability to analyze the enzyme reaction kinetics. Herein, we describe a custom reaction chamber with reaction medium recirculation and filtering and an imaging system that permits the continuous monitoring of in-gel enzymatic activity even in the presence of turbidity. Images were continuously collected using time-lapse high-resolution digital imaging, and processing routines were developed to obtain kinetic traces of the in-gel activities and analyze reaction time courses. This system also permitted the evaluation of enzymatic activity topology within the protein bands of the gel. This approach was used to analyze the reaction kinetics of two mitochondrial complexes in native gels. Complex IV kinetics showed a short initial linear phase in which catalytic rates could be calculated, whereas Complex V activity revealed a significant lag phase followed by two linear phases. The utility of monitoring the entire kinetic behavior of these reactions in native gels, as well as the general application of this approach, is discussed. Published by Elsevier Inc.
Landau, Z; Rachmiel, M; Pinhas-Hamiel, O; Boaz, M; Bar-Dayan, Y; Wainstein, J; Tauman, R
2014-01-01
To compare sleep quality and sleep-wake patterns in parents of children with type 1 diabetes before routine use of the continuous glucose monitoring system (CGMS) and while using it. Thirteen parents completed the Pittsburg Sleep Quality Index (PSQI), a 7-day sleep diary, and wore an actigraph (a wristwatch-size motion detector) during the night for 1 week before pediatric use of CGMS and 4-8 weeks after initiating routine use of the CGMS. Mean age of parents (ten mothers, three fathers) was 39 (range 32-47) years; mean age of children was 9.3 years (range 5.5-16.5 years); mean disease duration was 3.4 (range 0.6-11.2) years. PSQI total score demonstrated similar quality of sleep with and without use of the CGMS (4.6 and 4.9, respectively, p = 0.45). Six of the 13 parents reported severe sleep problems (PSQI ≥ 5) with and without the CGMS. The sleep diary indicated a greater number of awakening episodes during CGMS use than without the CGMS (1.6 and 1, respectively, p = 0.03), and actigraphy documented an increase in the number of wake bouts (22.9 and 19.7, p = 0.03) as well as in total wake time (48.3 and 42.2 min, p = 0.03) during CGMS use as compared with the period prior to CGMS use. Although self-perception of sleep quality remained unchanged, CGMS use appeared to affect actual parental sleep continuity somewhat negatively. This should be made clear to parents who may hold expectations of improvement in sleep quality following initiation of CGMS use.
Shibata, Mai; Hashi, Sachiyo; Nakanishi, Haruka; Masuda, Satohiro; Katsura, Toshiya; Yano, Ikuko
2012-12-01
The purpose of this study was to develop an ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method of 22 antiepileptics for routine therapeutic monitoring. The antiepileptics used in the analyses were carbamazepine, carbamazepine-10,11-epoxide, clobazam, N-desmethylclobazam, clonazepam, diazepam, N-desmethyldiazepam, ethosuximide, felbamate, gabapentin, lamotrigine, levetiracetam, N-desmethylmesuximide, nitrazepam, phenobarbital, phenytoin, primidone, tiagabine, topiramate, valproic acid, vigabatrin and zonisamide. After protein precipitation of 50 μL plasma with methanol, the supernatant was diluted with water or was evaporated to dryness and reconstituted with mobile phase in the case of benzodiazepines. Separation was achieved on an Acquity UPLC BEH C₁₈ column with a gradient mobile phase of 10 mm ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.4 mL/min. An Acquity TQD instrument in multiple reaction monitoring mode with ion mode switching was used for detection. All antiepileptics were detected and quantified within 10 min, with no endogenous interference. All the calibration curves showed good linearity in the therapeutic range (r² < 0.99). The precision and accuracy values for intra- and inter-assays were within ±15% except for phenobarbital and tiagabine. A good correlation was observed between the concentration of clinical samples measured by the new method described here and the conventional methods. The values of carbamazepine and phenytoin by UPLC-MS/MS were lower than those detected by the immunoassays, which might be caused by the cross-reaction of antibodies with their metabolites. In conclusion, we developed a simple and selective UPLC-MS/MS method suitable for routine therapeutic monitoring of antiepileptics. Copyright © 2012 John Wiley & Sons, Ltd.
Elements of an integrated health monitoring framework
NASA Astrophysics Data System (ADS)
Fraser, Michael; Elgamal, Ahmed; Conte, Joel P.; Masri, Sami; Fountain, Tony; Gupta, Amarnath; Trivedi, Mohan; El Zarki, Magda
2003-07-01
Internet technologies are increasingly facilitating real-time monitoring of Bridges and Highways. The advances in wireless communications for instance, are allowing practical deployments for large extended systems. Sensor data, including video signals, can be used for long-term condition assessment, traffic-load regulation, emergency response, and seismic safety applications. Computer-based automated signal-analysis algorithms routinely process the incoming data and determine anomalies based on pre-defined response thresholds and more involved signal analysis techniques. Upon authentication, appropriate action may be authorized for maintenance, early warning, and/or emergency response. In such a strategy, data from thousands of sensors can be analyzed with near real-time and long-term assessment and decision-making implications. Addressing the above, a flexible and scalable (e.g., for an entire Highway system, or portfolio of Networked Civil Infrastructure) software architecture/framework is being developed and implemented. This framework will network and integrate real-time heterogeneous sensor data, database and archiving systems, computer vision, data analysis and interpretation, physics-based numerical simulation of complex structural systems, visualization, reliability & risk analysis, and rational statistical decision-making procedures. Thus, within this framework, data is converted into information, information into knowledge, and knowledge into decision at the end of the pipeline. Such a decision-support system contributes to the vitality of our economy, as rehabilitation, renewal, replacement, and/or maintenance of this infrastructure are estimated to require expenditures in the Trillion-dollar range nationwide, including issues of Homeland security and natural disaster mitigation. A pilot website (http://bridge.ucsd.edu/compositedeck.html) currently depicts some basic elements of the envisioned integrated health monitoring analysis framework.
Lopes, Vitor Sergio Almeida; Riente, Roselene Ribeiro; da Silva, Alexsandro Araújo; Torquilho, Delma Falcão; Carreira, Renato da Silva; Marques, Mônica Regina da Costa
2016-09-15
A single method modified for monitoring of emerging contaminants in river water was developed for large sample volumes. Water samples from rivers of the lagoon system in the city of Rio de Janeiro (Brazil) were analyzed by the SPE-HPLC-MS-TOF analytical method. Acetaminophen was detected in four rivers in the concentration range of 0.09μgL(-1) to 0.14μgL(-1). Salicylic acid was also found in the four rivers in the concentration range of 1.65μgL(-1) to 4.81μgL(-1). Bisphenol-A was detected in all rivers in the concentration range of 1.37μgL(-1) to 39.86μgL(-1). Diclofenac was found in only one river, with concentration of 0.22μgL(-1). The levels of emerging organic pollutants in the water samples of the Jacarepaguá hydrographical basin are significant. The compounds are not routinely monitored and present potential risks to environmental health. Copyright © 2016 Elsevier Ltd. All rights reserved.
International Space Station Acoustics - A Status Report
NASA Technical Reports Server (NTRS)
Allen, Christopher S.; Denham, Samuel A.
2011-01-01
It is important to control acoustic noise aboard the International Space Station (ISS) to provide a satisfactory environment for voice communications, crew productivity, and restful sleep, and to minimize the risk for temporary and permanent hearing loss. Acoustic monitoring is an important part of the noise control process on ISS, providing critical data for trend analysis, noise exposure analysis, validation of acoustic analysis and predictions, and to provide strong evidence for ensuring crew health and safety, thus allowing Flight Certification. To this purpose, sound level meter (SLM) measurements and acoustic noise dosimetry are routinely performed. And since the primary noise sources on ISS include the environmental control and life support system (fans and airflow) and active thermal control system (pumps and water flow), acoustic monitoring will indicate changes in hardware noise emissions that may indicate system degradation or performance issues. This paper provides the current acoustic levels in the ISS modules and sleep stations, and is an update to the status presented in 20031. Many new modules, and sleep stations have been added to the ISS since that time. In addition, noise mitigation efforts have reduced noise levels in some areas. As a result, the acoustic levels on the ISS have improved.
SUPPORTING TEACHERS IN IMPLEMENTING FORMATIVE ASSESSMENT PRACTICES IN EARTH SYSTEMS SCIENCE
NASA Astrophysics Data System (ADS)
Harris, C. J.; Penuel, W. R.; Haydel Debarger, A.; Blank, J. G.
2009-12-01
An important purpose of formative assessment is to elicit student thinking to use in instruction to help all students learn and inform next steps in teaching. However, formative assessment practices are difficult to implement and thus present a formidable challenge for many science teachers. A critical need in geoscience education is a framework for providing teachers with real-time assessment tools as well as professional development to learn how to use formative assessment to improve instruction. Here, we describe a comprehensive support system, developed for our NSF-funded Contingent Pedagogies project, for addressing the challenge of helping teachers to use formative assessment to enhance student learning in middle school Earth Systems science. Our support system is designed to improve student understanding about the geosphere by integrating classroom network technology, interactive formative assessments, and contingent curricular activities to guide teachers from formative assessment to instructional decision-making and improved student learning. To accomplish this, we are using a new classroom network technology, Group Scribbles, in the context of an innovative middle-grades Earth Science curriculum called Investigating Earth Systems (IES). Group Scribbles, developed at SRI International, is a collaborative software tool that allows individual students to compose “scribbles” (i.e., drawings and notes), on “post-it” notes in a private workspace (a notebook computer) in response to a public task. They can post these notes anonymously to a shared, public workspace (a teacher-controlled large screen monitor) that becomes the centerpiece of group and class discussion. To help teachers implement formative assessment practices, we have introduced a key resource, called a teaching routine, to help teachers take advantage of Group Scribbles for more interactive assessments. Routine refers to a sequence of repeatable interactions that, over time, become automatic to teachers and students. Routines function as classroom norms, governing how students and teachers interact with subject matter (i.e., the way ideas are elicited, taken up, and revised). We use the qualifier teaching because we view good classroom assessment as seamless with instruction. Each teaching routine defines a sequence of instructional moves, supported by classroom network technology, for creating formative assessment opportunities that address 3 goals: (1) Increase student-teacher and student-student communication;(2) Motivate students to participate and learn from discussion, investigation, and reading; and (3) Provide real-time feedback for the teacher who can then adjust instruction. We report on key features of our support system for helping teachers develop proficiency with using formative assessment to inform instruction and advance learning in Earth Systems science. We also present preliminary findings from the implementation of the support system with a test group of teachers in a large, urban school district. Findings highlight the promise of teaching routines as an important resource for structuring student opportunities to showcase their thinking.
A Nursing Intelligence System to Support Secondary Use of Nursing Routine Data
Rauchegger, F.; Ammenwerth, E.
2015-01-01
Summary Background Nursing care is facing exponential growth of information from nursing documentation. This amount of electronically available data collected routinely opens up new opportunities for secondary use. Objectives To present a case study of a nursing intelligence system for reusing routinely collected nursing documentation data for multiple purposes, including quality management of nursing care. Methods The SPIRIT framework for systematically planning the reuse of clinical routine data was leveraged to design a nursing intelligence system which then was implemented using open source tools in a large university hospital group following the spiral model of software engineering. Results The nursing intelligence system is in routine use now and updated regularly, and includes over 40 million data sets. It allows the outcome and quality analysis of data related to the nursing process. Conclusions Following a systematic approach for planning and designing a solution for reusing routine care data appeared to be successful. The resulting nursing intelligence system is useful in practice now, but remains malleable for future changes. PMID:26171085
NASA Astrophysics Data System (ADS)
Yuval; Rimon, Y.; Graber, E. R.; Furman, A.
2013-07-01
A large fraction of the fresh water available for human use is stored in groundwater aquifers. Since human activities such as mining, agriculture, industry and urbanization often result in incursion of various pollutants to groundwater, routine monitoring of water quality is an indispensable component of judicious aquifer management. Unfortunately, groundwater pollution monitoring is expensive and usually cannot cover an aquifer with the spatial resolution necessary for making adequate management decisions. Interpolation of monitoring data between points is thus an important tool for supplementing measured data. However, interpolating routine groundwater pollution data poses a special problem due to the nature of the observations. The data from a producing aquifer usually includes many zero pollution concentration values from the clean parts of the aquifer but may span a wide range (up to a few orders of magnitude) of values in the polluted areas. This manuscript presents a methodology that can cope with such datasets and use them to produce maps that present the pollution plumes but also delineates the clean areas that are fit for production. A method for assessing the quality of mapping in a way which is suitable to the data's dynamic range of values is also presented. Local variant of inverse distance weighting is employed to interpolate the data. Inclusion zones around the interpolation points ensure that only relevant observations contribute to each interpolated concentration. Using inclusion zones improves the accuracy of the mapping but results in interpolation grid points which are not assigned a value. That inherent trade-off between the interpolation accuracy and coverage is demonstrated using both circular and elliptical inclusion zones. A leave-one-out cross testing is used to assess and compare the performance of the interpolations. The methodology is demonstrated using groundwater pollution monitoring data from the Coastal aquifer along the Israeli shoreline.
Permanent downhole fiber optic pressure and temperature monitoring during CO2 injection
NASA Astrophysics Data System (ADS)
Schmidt-Hattenberger, C.; Moeller, F.; Liebscher, A.; Koehler, S.
2009-04-01
Permanent downhole monitoring of pressure and temperature, ideally over the entire length of the injection string, is essential for any smooth and safe CO2 injection within the framework of geological CO2 storage: i) To avoid fracturing of the cap-rock, a certain, site dependent pressure threshold within the reservoir should not be exceeded; ii) Any CO2 phase transition within the injection string, i.e. either condensation or evaporation, should be avoided. Such phase transitions cause uncontrolled and undetermined P-T regimes within the injection string that may ultimately result in a shut-in of the injection facility; and iii) Precise knowledge of the P and T response of the reservoir to the CO2 injection is a prerequisite to any reservoir modeling. The talk will present first results from our permanent downhole P-T monitoring program from the Ketzin CO2 storage test site (CO2SINK). At Ketzin, a fiber Bragg grating pressure sensor has been installed at the end of the injection string in combination with distributed temperature profiling over the entire length (about 550 m) of the string for continuous P-T monitoring during operation. Such fiber optic monitoring technique is used by default in the oil and gas industry but has not yet been applied as standard on a long-term routine mode for CO2 injection. Pressure is measured every 5 seconds with a resolution of < 1 bar. The data are later processed by user-defined program. The temperature logs along the injection string are measured every 3 minutes with a spatial resolution of one meter and with a temperature resolution of about 0.1°C. The long-term stability under full operational conditions is currently under investigation. The main computer of the P-T system operates as a stand-alone data-acquisition unit, and is connected with a secure intranet in order to ensure remote data access and system maintenance. The on-line measurements are displayed on the operator panel of the injection facility for direct control. The monitoring program started already prior to CO2 injection and runs since 6 months without any fatal errors. The recorded data cover the pre-injection well-testing phase, the initial injection phase as well as several shut-in and re-start phases during routine injection. Especially during the initial and re-start phases the monitoring results significantly optimized and improved the operation of the injection facility in terms of injection rate and injection temperature. Due to the high qualitative and also quantitative resolution of this technique even shortest-term transient disturbances of the reservoir and injection regime could be monitored as they may occur due to fluid sampling or logging in neighboring wells. Such short-term transient effects are normally overlooked using non-permanent monitoring techniques. On the long-term perspective, this monitoring technique will also support the control of CO2 injection tubing integrity, which is a prerequisite for any secure long-lasting CO2 injection and storage.
The GEOGLAM Rangelands and Pasture Productivity Activity: Recent Progress and Future Directions
NASA Astrophysics Data System (ADS)
Guerschman, J. P.; Held, A. A.; Donohue, R. J.; Renzullo, L. J.; Sims, N.; Kerblat, F.; Grundy, M.
2015-12-01
Rangelands and pastures cover about a third of the world's land area and support livestock production which represents ~40% of global agricultural gross domestic product. The global consumption of animal protein shows a clear increasing trend, driven by both total population and per capita income increases, putting a growing pressure on the sustainability of grazing lands worldwide. Despite their relevance, rangelands have received less attention than croplands regarding global monitoring of the resource productivity and condition. The Rangelands and Pasture Productivity (RaPP) activity is a component within the Global Agricultural Monitoring initiative established under the Group on Earth Observations (GEOGLAM) in 2013. GEOGLAM RaPP is aimed at providing the global community with the means to monitor the world's rangelands and pastures on a routine basis, and the capacity to produce animal protein in real-time, at global, regional and national levels. Since its launch two years ago GEOGLAM RAPP has made progress in the four implementation elements. These include: 1- the establishment of community of practice; 2- the development of a global monitoring system for rangeland condition; 3- the establishment of pilot sites in main rangeland systems for satellite data products validation and model testing; and 4- integration with livestock production models. Three international workshops have been held building the community of practice. A prototype monitoring system that provides global visualisations and querying capability of vegetation cover data and anomalies has been established. Pilot sites, mostly in areas with long records of field measurements of rangeland condition and productivity have been proposed for nine countries. The link to global livestock models, including physical and economic components, have been established. Future challenges for GEOGLAM RaPP have also been identified and include: better representation of the areas occupied by rangelands, pastures and mixed systems globally; intercomparison and validation of satellite data products and models depicting rangeland condition and forage availability; and better understanding of the environmental and social impacts of the potential use of pastures for biofuel production.
An Introduction to the Global Space-based Inter-Calibration System from a EUMETSAT Perspective
NASA Astrophysics Data System (ADS)
Wagner, S. C.; Hewison, T.; Roebeling, R. A.; Koenig, M.; Schulz, J.; Miu, P.
2012-04-01
The Global Space-based Inter-Calibration System (GSICS) (Goldberg and al. 2011) is an international collaborative effort which aims to monitor, improve and harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications. This is achieved through a comprehensive calibration strategy, which involves monitoring instrument performances, operational inter-calibration of satellite instruments, tying the measurements to absolute references and standards, and recalibration of archived data. A major part of this strategy involves direct comparison of collocated observations from pairs of satellite instruments, which are used to systematically generate calibration functions to compare and correct the calibration of monitored instruments to references. These GSICS Corrections are needed for accurately integrating data from multiple observing systems into both near real-time and re-analysis products, applications and services. This paper gives more insight into the activities carried out by EUMETSAT as a GSICS Processing and Research Centre. Currently these are closely bound to the in-house development and operational implementation of calibration methods for solar and thermal band channels of geostationary and polar-orbiting satellites. They include inter-calibration corrections for Meteosat imagers using reference instruments such as the Moderate Resolution Imaging Spectroradiometer (MODIS) on-board the Aqua satellite for solar band channels, the Infrared Atmospheric Sounding Interferometer (IASI) on-board Metop-A and, for historic archive data, the High-resolution InfraRed Sounder (HIRS). Additionally, bias monitoring is routinely performed, allowing users to visualise the calibration accuracy of the instruments in near real-time. These activities are based on principles and protocols defined by the GSICS Research Working Group and Data Management Working Group, which require assessment of the calibration uncertainties to ensure the traceability to community references.
Summary of Part 75 Administrative Processes: Table 1
Learn how to submit your initial certification, recertification, monitoring plans, routine quality assurance tests, diagnostic tests and DAHS verifications, low mass emissions units and other notification requirements. Table 1, initial certification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2012 CFR
2012-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...