Multi-detector CT angiography of the aortic valve—Part 2: disease specific findings
Ganeshan, Arul
2014-01-01
The aortic valve and adjacent structures should be routinely evaluated on all thoracic cross-sectional imaging studies. Echocardiography and magnetic resonance imaging (MRI) are the main imaging techniques used for assessment of the aortic valve and related pathology but multi-detector computed tomography (MDCT) can offer valuable complimentary information in some clinical scenarios. MDCT is the definite means of assessing aortic valvular calcification, acute aortic syndrome and for non-invasive assessment of the coronary arteries. MDCT also has an emerging role in the planning and follow-up of trans-catheter aortic valve replacement. This article reviews the spectrum of aortic valve disease highlighting the key MDCT imaging features. PMID:25202663
Current role of multidetector computed tomography in imaging of wrist injuries.
Syed, Mohd Arif; Raj, Vimal; Jeyapalan, Kanagaratnam
2013-01-01
Imaging of the wrist is challenging to both radiologists and orthopedic surgeons. This is primarily because of the complex anatomy/functionality of the wrist and also the fact that many frequent injuries are sustained to the hands. On going developments in multidetector computed tomography (MDCT) technology with its "state of the art" postprocessing capabilities have revolutionized this field. Apart from routine imaging of wrist trauma, it is now possible to assess intrinsic ligaments with MDCT arthrography, thereby avoiding invasive diagnostic arthroscopies. Postoperative wrist imaging can be a diagnostic challenge, and MDCT can be helpful in assessment of these cases because volume acquisition and excellent postprocessing abilities help to evaluate these wrists in any desired plane and thinner slices. This article pictorially reviews the current clinical role of MDCT imaging of wrist in our practice. It also describes arthrography technique and scanning parameters used at our center. Copyright © 2013 Mosby, Inc. All rights reserved.
Application of multidetector-row computed tomography in propeller flap planning.
Ono, Shimpei; Chung, Kevin C; Hayashi, Hiromitsu; Ogawa, Rei; Takami, Yoshihiro; Hyakusoku, Hiko
2011-02-01
The propeller flap is defined as (1) being island-shaped, (2) having an axis that includes the perforators, and (3) having the ability to be rotated around an axis. The advantage of the propeller flap is that it is a pedicle flap that can be applied to cover defects located at the distal ends of the extremities. The specific aims of the authors' study were (1) to evaluate the usefulness of multidetector-row computed tomography in the planning of propeller flaps and (2) to present a clinical case series of propeller flap reconstructions that were planned preoperatively using multidetector-row computed tomography. The authors retrospectively analyzed all cases between April of 2007 and April of 2010 at Nippon Medical School Hospital in Tokyo, where multidetector-row computed tomography was used preoperatively to plan surgical reconstructions using propeller flaps. Thirteen patients underwent 16 flaps using the propeller flap technique. The perforators were identified accurately by multidetector-row computed tomography preoperatively in all cases. This is the first report describing the application of multidetector-row computed tomography in the planning of propeller flaps. Multidetector-row computed tomography is superior to other imaging methods because it demonstrates more precisely the perforator's position and subcutaneous course using high-resolution three-dimensional images. By using multidetector-row computed tomography to preoperatively identify a flap's perforators, the surgeon can better plan the flap design to efficiently conduct the flap surgery.
Martina, Maria Cristina; Cesarani, Federico; Boano, Rosa; Fiore Marochetti, Elisa; Gandini, Giovanni
The objective of our work was to report the most recent findings obtained with multidetector computed tomography of a child mummy from the Roman period (119-123 CE) housed at the Egyptian Museum in Turin, Italy. Multidetector computed tomography and postprocessing were applied to understand the embalming techniques, the nature of a foreign object, and anthropometrical values. The information was compared with that from other mummies that were buried in the same tomb, but today housed in different museums. New information regarding the embalming technique was revealed. Multidetector computed tomography allowed the identification of a knife-like metallic object, probably an amulet for the child's protection in the afterlife. Multidetector computed tomography and image postprocessing confirm their valuable role in noninvasive studies in ancient mummies and provided evidence of a unique cultural practice in the late history of Ancient Egypt such as placing a knife possibly as an amulet.
Patent foramen ovale: detection with nongated multidetector CT.
Revel, Marie-Pierre; Faivre, Jean-Baptiste; Letourneau, Thierry; Henon, Hilde; Leys, Didier; Delannoy-Deken, Valérie; Remy-Jardin, Martine; Remy, Jacques
2008-10-01
To evaluate nongated multidetector computed tomography (CT) in the detection of patent foramen ovale (PFO) and atrial septal aneurysm (ASA) in comparison with transesophageal echocardiography (TEE). The study was approved by the institutional review board, and informed consent was obtained from all patients. One hundred five patients (57 men, 48 women; mean age, 53 years) with a recent stroke underwent TEE and multidetector CT on the same day. After injection of a diluted iodinated contrast material, a series of 2.4-mm-thick transverse images centered on the fossa ovalis were acquired in conjunction with release of the Valsalva maneuver. Two independent radiologists considered PFO present if left atrial enhancement was detected visually before enhancement of the pulmonary veins or if an early peak of left atrial enhancement was found at time-attenuation curve analysis. PFO was detected with 98% specificity (95% confidence interval [CI]: 0.91, 0.99). Overall sensitivity was 55% (95% CI: 0.38, 0.70), ranging from 28% for shunts classified as grade 1 at TEE to 91% for those classified as grade 4 at TEE. Interreader agreement was good (kappa = 0.81). Visual assessment was better than time-attenuation curve analysis, which enabled detection of only 15 of the 40 cases of PFO. Multidetector CT depicted only 22% of cases of ASA. The mean effective radiation dose was 2.3 mSv. Nongated multidetector CT can be used to diagnose high-grade shunts through a PFO, with 91% sensitivity and 98% specificity. Thus, PFO detection, in addition to routine CT evaluation of the lungs, could be indicated in patients with unexplained hypoxemia. (c) RSNA, 2008.
Eren, Suat
2010-01-01
Objective: To evaluate the efficacy of multi-detector row CT (MDCT) on pelvic congestion syndrome (PCS), which is often overlooked or poorly visualized with routine imaging examination. Materials and Methods: We evaluated the MDCT features of 40 patients with PCS (mean age, 45 years; range, 29–60 years) using axial, coronal, sagittal, 3D volume-rendered, and Maximum Intensity Projection MIP images. Results: MDCT revealed pelvic varices and ovarian vein dilatations in all patients. Bilateral ovarian vein dilatation was present in 25 patients, and 15 patients had unilateral dilatation. While 12 cases of secondary pelvic varices occurred simultaneously with a retroaortic left renal vein, 10 cases were due solely to a mass obstruction or stenosis of venous structures. Conclusion: MDCT is an effective tool in the evaluation of PCS, and it has more advantages than other imaging modalities. PMID:25610142
Multidetector Computed Tomography for Congenital Anomalies of the Aortic Arch: Vascular Rings.
García-Guereta, Luis; García-Cerro, Estefanía; Bret-Zurita, Montserrat
2016-07-01
The development of multidetector computed tomography has triggered a revolution in the study of the aorta and other large vessels and has replaced angiography in the diagnosis of congenital anomalies of the aortic arch, particularly vascular rings. The major advantage of multidetector computed tomography is that it permits clear 3-dimensional assessment of not only vascular structures, but also airway and esophageal compression. The current update aims to summarize the embryonic development of the aortic arch and the developmental anomalies leading to vascular ring formation and to discuss the current diagnostic and therapeutic role of multidetector computed tomography in this field. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Jung, Chang Hee; Hwang, Jenie Yoonoo; Shin, Mi Seon; Yu, Ji Hee; Kim, Eun Hee; Bae, Sung Jin; Yang, Dong Hyun; Kang, Joon-Won; Park, Joong-Yeol; Kim, Hong-Kyu
2013-01-01
Despite the noninvasiveness and accuracy of multidetector computed tomography (MDCT), its use as a routine screening tool for occult coronary atherosclerosis is unclear. We investigated whether the ratio of apolipoprotein B (apoB) to apolipoprotein A1 (apoA1), an indicator of the balance between atherogenic and atheroprotective cholesterol transport could predict occult coronary atherosclerosis detected by MDCT. We collected the data of 1,401 subjects (877 men and 524 women) who participated in a routine health screening examination of Asan Medical Center. Significant coronary artery stenosis defined as > 50% stenosis was detected in 114 subjects (8.1%). An increase in apoB/A1 quartiles was associated with increased percentages of subjects with significant coronary stenosis and noncalcified plaques (NCAP). After adjustment for confounding variables, each 0.1 increase in serum apoB/A1 was significantly associated with increased odds ratios (ORs) for coronary stenosis and NCAP of 1.23 and 1.18, respectively. The optimal apoB/A1 ratio cut off value for MDCT detection of significant coronary stenosis was 0.58, which had a sensitivity of 70.2% and a specificity of 48.2% (area under the curve, 0.61; 95% CI, 0.58-0.63, P < 0.001). Our results indicate that apoB/A1 ratio is a good indicator of occult coronary atherosclerosis detected by coronary MDCT. PMID:23678262
Jung, Chang Hee; Hwang, Jenie Yoonoo; Shin, Mi Seon; Yu, Ji Hee; Kim, Eun Hee; Bae, Sung Jin; Yang, Dong Hyun; Kang, Joon-Won; Park, Joong-Yeol; Kim, Hong-Kyu; Lee, Woo Je
2013-05-01
Despite the noninvasiveness and accuracy of multidetector computed tomography (MDCT), its use as a routine screening tool for occult coronary atherosclerosis is unclear. We investigated whether the ratio of apolipoprotein B (apoB) to apolipoprotein A1 (apoA1), an indicator of the balance between atherogenic and atheroprotective cholesterol transport could predict occult coronary atherosclerosis detected by MDCT. We collected the data of 1,401 subjects (877 men and 524 women) who participated in a routine health screening examination of Asan Medical Center. Significant coronary artery stenosis defined as > 50% stenosis was detected in 114 subjects (8.1%). An increase in apoB/A1 quartiles was associated with increased percentages of subjects with significant coronary stenosis and noncalcified plaques (NCAP). After adjustment for confounding variables, each 0.1 increase in serum apoB/A1 was significantly associated with increased odds ratios (ORs) for coronary stenosis and NCAP of 1.23 and 1.18, respectively. The optimal apoB/A1 ratio cut off value for MDCT detection of significant coronary stenosis was 0.58, which had a sensitivity of 70.2% and a specificity of 48.2% (area under the curve, 0.61; 95% CI, 0.58-0.63, P < 0.001). Our results indicate that apoB/A1 ratio is a good indicator of occult coronary atherosclerosis detected by coronary MDCT.
Soukup, Jason W; Drees, Randi; Koenig, Lisa J; Snyder, Christopher J; Hetzel, Scott; Miles, Chanda R; Schwarz, Tobias
2015-01-01
The objective of this blinded study was to validate the use of cone beam computed tomography (C) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methylmethacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxillary segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT.
Soukup, Jason W.; Drees, Randi; Koenig, Lisa J.; Snyder, Christopher J.; Hetzel, Scott; Miles, Chanda R.; Schwarz, Tobias
2016-01-01
Summary The objective of this blinded study was to validate the use of cone beam computed tomography (CT) for imaging of the canine maxillary dentoalveolar structures by comparing its diagnostic image quality with that of 64-multidetector row CT. Sagittal slices of a tooth-bearing segment of the maxilla of a commercially purchased dog skull embedded in methyl methacrylate were obtained along a line parallel with the dental arch using a commercial histology diamond saw. The slice of tooth-bearing bone that best depicted the dentoalveolar structures was chosen and photographed. The maxilla segment was imaged with cone beam CT and 64-multidetector row CT. Four blinded evaluators compared the cone beam CT and 64-multidetector row CT images and image quality was scored as it related to the anatomy of dentoalveolar structures. Trabecular bone, enamel, dentin, pulp cavity, periodontal ligament space, and lamina dura were scored. In addition, a score depicting the evaluators overall impression of the image was recorded. Images acquired with cone beam CT were found to be significantly superior in image quality to images acquired with 64-multidetector row CT overall, and in all scored categories. In our study setting, cone beam CT was found to be a valid and clinically superior imaging modality for the canine maxillary dentoalveolar structures when compared to 64-multidetector row CT. PMID:26415384
Multi-detector row computed tomography angiography of peripheral arterial disease
Dijkshoorn, Marcel L.; Pattynama, Peter M. T.; Myriam Hunink, M. G.
2007-01-01
With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. PMID:17882427
Mladenovic, Zorica; Vranes, Danijela; Obradovic, Slobodan; Dzudovic, Boris; Angelkov Ristic, Andjelka; Ratkovic, Nenad; Jovic, Zoran; Spasic, Marijan; Maric Kocijancic, Jelena; Djruic, Predrag
2018-06-04
Unicuspid aortic valve (UAV) is a rare congenital anomaly of aorta associated with a faster progress of valvular dysfunction, aortic dilatation and with necessity for more frequent controls and precise evaluation Asymptomatic 35 year old man had abnormal systolic diastolic murmur on aortic valve during routine examination. Initial diagnostic with transthoracic echocardiography (TTE) supposed bicuspid aortic valve, while three-dimensional transesophageal echocardiography (3D TEE) and multidetector computed tomography defined unicuspid, unicomissural aortic valve with moderate aortic stenosis and regurgitation. This case report confirmed that 3D TEE gives us opportunity for early, improved and precise diagnosis of UAV. © 2018 Wiley Periodicals, Inc.
Yun, Chun-Ho; Schlett, Christopher L; Rogers, Ian S; Truong, Quynh A; Toepker, Michael; Donnelly, Patrick; Brady, Thomas J; Hoffmann, Udo; Bamberg, Fabian
2009-08-01
The aim of the study was to assess differences in the presence, extent, and composition of coronary atherosclerotic plaque burden as detected by coronary multidetector computed tomography (MDCT) between patients with and without diabetes mellitus. We compared coronary atherosclerotic plaques (any plaque, calcified [CAP], non-calcified [NCAP, and mixed plaque [MCAP
Mejean, Simon; Bouvier, Erik; Bataille, Vincent; Seknadji, Patrick; Fourchy, Dominique; Tabet, Jean-Yves; Lairez, Olivier; Cormier, Bertrand
2016-10-15
Mitral annular calcium (MAC) is a common finding in older patients referred for transcatheter aortic valve implantation (TAVI). Multidetector computed tomography (MDCT) allows fine quantification of the calcific deposits. Our objective was to estimate the prevalence of MAC and associated mitral stenosis (MS) in patients referred for TAVI using MDCT. A cohort of 346 consecutive patients referred for TAVI evaluation was screened by MDCT for MAC: 174 had MAC (50%). Of these patients, 165 patients (95%) had mitral valve area (MVA) assessable by MDCT planimetry (age 83.8 ± 5.9 years). Median mitral calcium volume and MVA were 545 mm 3 (193 to 1,253 mm 3 ) and 234 mm 2 (187 to 297 mm 2 ), respectively. The MS was very severe, severe, and moderate in 2%, 22%, and 10% patients, respectively. By multivariate analysis, MVA was independently correlated to mitral calcium volume, aortic annular area, and some specific patterns of mitral leaflet calcium. Based on these findings, a formula was elaborated to predict the presence of a significant MS. In conclusion, MDCT allows detailed assessment of MAC in TAVI populations, demonstrating a high prevalence. Mitral analysis should become routine during MDCT screening before TAVI as it may alter therapeutic strategy. Copyright © 2016 Elsevier Inc. All rights reserved.
Role of virtual bronchoscopy in children with a vegetable foreign body in the tracheobronchial tree.
Behera, G; Tripathy, N; Maru, Y K; Mundra, R K; Gupta, Y; Lodha, M
2014-12-01
Multidetector computed tomography virtual bronchoscopy is a non-invasive diagnostic tool which provides a three-dimensional view of the tracheobronchial airway. This study aimed to evaluate the usefulness of virtual bronchoscopy in cases of vegetable foreign body aspiration in children. The medical records of patients with a history of foreign body aspiration from August 2006 to August 2010 were reviewed. Data were collected regarding their clinical presentation and chest X-ray, virtual bronchoscopy and rigid bronchoscopy findings. Cases of metallic and other non-vegetable foreign bodies were excluded from the analysis. Patients with multidetector computed tomography virtual bronchoscopy showing features of vegetable foreign body were included in the analysis. For each patient, virtual bronchoscopy findings were reviewed and compared with those of rigid bronchoscopy. A total of 60 patients; all children ranging from 1 month to 8 years of age, were included. The mean age at presentation was 2.01 years. Rigid bronchoscopy confirmed the results of multidetector computed tomography virtual bronchoscopy (i.e. presence of foreign body, site of lodgement, and size and shape) in 59 patients. In the remaining case, a vegetable foreign body identified by virtual bronchoscopy was revealed by rigid bronchoscopy to be a thick mucus plug. Thus, the positive predictive value of virtual bronchoscopy was 98.3 per cent. Multidetector computed tomography virtual bronchoscopy is a sensitive and specific diagnostic tool for identifying radiolucent vegetable foreign bodies in the tracheobronchial tree. It can also provide a useful pre-operative road map for rigid bronchoscopy. Patients suspected of having an airway foreign body or chronic unexplained respiratory symptoms should undergo multidetector computed tomography virtual bronchoscopy to rule out a vegetable foreign body in the tracheobronchial tree and avoid general anaesthesia and invasive rigid bronchoscopy.
Ectopic Multinodular Goiter: Multidetector Computed Tomography Findings
Karakaya, Afak Durur; Kantarci, Mecit; Yalcin, Ahmet; Demir, Berrin
2008-01-01
The thyroid is the first endocrine gland to form during embryogenesis. At this stage, incomplete or anomalous migration of thyroid tissue causes ectopic localization of the gland. In our case, a 55-year-old woman who was evaluated via ultrasonography (USG) and multi-detector computed tomography (MDCT) had no thyroid gland at the normal location, but did have ectopic thyroid tissue in the left submandibular and submental regions. PMID:25610021
Carlson, Matthew L; Leng, Shuai; Diehn, Felix E; Witte, Robert J; Krecke, Karl N; Grimes, Josh; Koeller, Kelly K; Bruesewitz, Michael R; McCollough, Cynthia H; Lane, John I
2017-08-01
A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.
Multi-detector CT imaging in the postoperative orthopedic patient with metal hardware.
Vande Berg, Bruno; Malghem, Jacques; Maldague, Baudouin; Lecouvet, Frederic
2006-12-01
Multi-detector CT imaging (MDCT) becomes routine imaging modality in the assessment of the postoperative orthopedic patients with metallic instrumentation that degrades image quality at MR imaging. This article reviews the physical basis and CT appearance of such metal-related artifacts. It also addresses the clinical value of MDCT in postoperative orthopedic patients with emphasis on fracture healing, spinal fusion or arthrodesis, and joint replacement. MDCT imaging shows limitations in the assessment of the bone marrow cavity and of the soft tissues for which MR imaging remains the imaging modality of choice despite metal-related anatomic distortions and signal alteration.
Raman, Siva P; Lessne, Mark; Kawamoto, Satomi; Chen, Yifei; Salvatori, Roberto; Prescott, Jason D; Fishman, Elliot K
2015-01-01
The management of patients with primary hyperaldosteronism (PH) varies depending on whether the unregulated aldosterone secretion localizes to a single unilateral adrenal gland, traditionally determined using adrenal vein sampling (AVS). This study seeks to determine if the performance of multidetector computed tomography (MDCT) examinations performed using the latest scanner technology can reasonably match the results of AVS, and potentially avoid AVS in some patients. Computed tomographic scans in 56 patients with PH were independently reviewed by 2 radiologists for the presence of adrenal nodules and qualitative adrenal thickening. Results were correlated with AVS results. Of 35 patients with MDCT evidence of unilateral nodules, the imaging findings correctly predicted AVS localization in only 23 (65.7%) cases. When stratified by size, MDCT was accurate in only 71.4% of cases for nodules measuring 10 mm or less, and only 55.0% of cases for nodules measuring 11 to 20 mm. Of the 12 cases where MDCT did not correctly localize, AVS localized to the contralateral adrenal gland in 4 cases, whereas AVS suggested no lateralization in 8 cases. In patients with normal bilateral adrenal glands on MDCT, 2/7 (28.6%) of cases demonstrated unilateral localization on AVS, and in patients with bilateral adrenal nodules, only 3/14 (21.4%) did not demonstrate lateralization on AVS. Multidetector computed tomography, even when performed with the latest generation of MDCT scanners, does not offer sufficient diagnostic accuracy to replace AVS in patients with PH.
Femoral head avascular necrosis: a frequently missed incidental finding on multidetector CT.
Barille, M F; Wu, Jim S; McMahon, Colm J
2014-03-01
To determine the incidence of missed femoral head avascular necrosis (AVN) on pelvic computed tomography (CT) performed for clinical indications other than assessment for AVN. The study was a Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study. The picture archiving and communication system (PACS) database was queried for patients with diagnosis of femoral head AVN on magnetic resonance imaging (MRI), who also underwent pelvic multidetector CT after or <30 days before the MRI examination. The MRI and CT images of 144 hips of 72 patients (39 patients with reported AVN on MRI and 33 age-matched controls; mean age = 60 years, 28 male, 44 female), were reviewed in consensus by two readers in a randomized, blinded manner. Using MRI-proven CT-visible AVN as a reference standard, the incidence of missed AVN on initial CT interpretation was determined. Readers confirmed AVN in 33 patients on the MRI images. Nine hips with AVN underwent joint replacement of the affected joint(s) prior to subsequent CT and were excluded. Forty-three MRI-proven AVN cases in 28 patients (15 bilateral, 13 unilateral) were available for analysis. The study readers diagnosed 35/43 (81%) MRI-proven AVN cases in 22/28 (79%) patients. Four of the 35 (11%) cases of MRI-proven, CT-visible AVN were prospectively reported in 3/22 (14%) patients at initial clinical interpretation, with a miss rate of 89% per hip and 86% per patient. Multidetector CT has high accuracy for detection of AVN; however, this is frequently missed as an incidental finding (89% missed in the present study). Assessment for signs of femoral AVN should be part of routine search pattern in interpretation of pelvic CT. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Molar mass averages, distributions, and architectural information of polymers are routinely obtained using size-exclusion chromatography (SEC). It has previously been shown that ultrahigh molar mass polymers may experience degradation during SEC analysis, leading to inaccurate molar mass averages a...
Bolliger, Stephan A; Ross, Steffen; Thali, Michael J; Hostettler, Bernhard; Menkveld-Gfeller, Ursula
2012-01-01
The study of fossils permits the reconstruction of past life on our planet and enhances our understanding of evolutionary processes. However, many fossils are difficult to recognize, being encased in a lithified matrix whose tedious removal is required before examination is possible. The authors describe the use of multidetector computed tomography (CT) in locating, identifying, and examining fossil remains of crocodilians (Mesosuchia) embedded in hard shale, all without removing the matrix. In addition, they describe how three-dimensional (3D) reformatted CT images provided details that were helpful for extraction and preparation. Multidetector CT can help experienced paleontologists localize and characterize fossils in the matrix of a promising rock specimen in a nondestructive manner. Moreover, with its capacity to generate highly accurate 3D images, multidetector CT can help determine whether the fossils warrant extraction and can assist in planning the extraction process. Thus, multidetector CT may well become an invaluable tool in the field of paleoradiology.
Sivanandam, S E; Mathew, Georgie; Bhat, Sanjay H
2009-07-01
Persistent hematuria is one of the most dreaded complications following percutanous nephrolithotomy (PCNL). Although invasive, a catheter-based angiogram is usually used to localize the bleeding vessel and subsequently embolize it. Advances in imaging technology have now made it possible to use a non invasive multi-detector computed tomography (MDCT) angiogram with 3-D reconstruction to establish the diagnosis. We report a case of post-PCNL hemorrhage due to a pseudo aneurysm that was missed by a conventional angiogram and subsequently detected on MDCT angiogram.
Moores, L; Kline, J; Portillo, A K; Resano, S; Vicente, A; Arrieta, P; Corres, J; Tapson, V; Yusen, R D; Jiménez, D
2016-01-01
ESSENTIALS: When high probability of pulmonary embolism (PE), sensitivity of computed tomography (CT) is unclear. We investigated the sensitivity of multidetector CT among 134 patients with a high probability of PE. A normal CT alone may not safely exclude PE in patients with a high clinical pretest probability. In patients with no clear alternative diagnosis after CTPA, further testing should be strongly considered. Whether patients with a negative multidetector computed tomographic pulmonary angiography (CTPA) result and a high clinical pretest probability of pulmonary embolism (PE) should be further investigated is controversial. This was a prospective investigation of the sensitivity of multidetector CTPA among patients with a priori clinical assessment of a high probability of PE according to the Wells criteria. Among patients with a negative CTPA result, the diagnosis of PE required at least one of the following conditions: ventilation/perfusion lung scan showing a high probability of PE in a patient with no history of PE, abnormal findings on venous ultrasonography in a patient without previous deep vein thrombosis at that site, or the occurrence of venous thromboembolism (VTE) in a 3-month follow-up period after anticoagulation was withheld because of a negative multidetector CTPA result. We identified 498 patients with a priori clinical assessment of a high probability of PE and a completed CTPA study. CTPA excluded PE in 134 patients; in these patients, the pooled incidence of VTE was 5.2% (seven of 134 patients; 95% confidence interval [CI] 1.5-9.0). Five patients had VTEs that were confirmed by an additional imaging test despite a negative CTPA result (five of 48 patients; 10.4%; 95% CI 1.8-19.1), and two patients had objectively confirmed VTEs that occurred during clinical follow-up of at least 3 months (two of 86 patients; 2.3%; 95% CI 0-5.5). None of the patients had a fatal PE during follow-up. A normal multidetector CTPA result alone may not safely exclude PE in patients with a high clinical pretest probability. © 2015 International Society on Thrombosis and Haemostasis.
Multidetector computed tomography diagnosis of gastric volvulus through the foramen of Morgagni.
Lecouvet, S; Coulier, B; Pierard, F; Gogoase, M; Coppens, J P; Van Hoof, M
2014-01-01
Morgagni hernia is considered to be the rarest form of all diaphragmatic hernias. It develops through a congenital defect in the retrosternal area. Usually asymptomatic, this entity can lead to life-threatening complications such as incarceration, strangulation or volvulus of the herniated viscus. We hereby report a rare case of organoaxial gastric volvulus producing through the foramen of Morgagni in a 78-year-old woman. The full diagnosis was made by upper gastro-intestinal series and multidetector computed tomography (MDCT). The basic anatomy, physiopathology, diagnostic methods, complications and surgical treatment of Morgagni hernia are briefly reviewed.
... Computed tomography scan - heart; Calcium scoring; Multi-detector CT scan - heart; Electron beam computed tomography - heart; Agatston ... table that slides into the center of the CT scanner. You will lie on your back with ...
Yamashita, Seigo; Sacher, Frédéric; Mahida, Saagar; Berte, Benjamin; Lim, Han S; Komatsu, Yuki; Amraoui, Sana; Denis, Arnaud; Derval, Nicolas; Laurent, François; Montaudon, Michel; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert
2015-04-01
Epicardial ventricular tachycardia (VT) ablation is associated with risks of coronary artery (CA) and phrenic nerve (PN) injury. We investigated the role of multidetector computed tomography in visualizing CA and PN during VT ablation. Ninety-five consecutive patients (86 men; age, 57 ± 15) with VT underwent cardiac multidetector computed tomography. The PN detection rate and anatomic variability were analyzed. In 49 patients undergoing epicardial mapping, real-time multidetector computed tomographic integration was used to display CAs/PN locations in 3-dimensional mapping systems. Elimination of local abnormal ventricular activities (LAVAs) was used as ablation end point. The distribution of CAs/PN with respect to LAVA was analyzed and compared between VT etiologies. Multidetector computed tomography detected PN in 81 patients (85%). Epicardial LAVAs were observed in 44 of 49 patients (15 ischemic cardiomyopathy, 15 nonischemic cardiomyopathy, and 14 arrhythmogenic right ventricular cardiomyopathy) with a mean of 35 ± 37 LAVA points/patient. LAVAs were located within 1 cm from CAs and PN in 35 (80%) and 18 (37%) patients, respectively. The prevalence of LAVA adjacent to CAs was higher in nonischemic cardiomyopathy and arrhythmogenic right ventricular cardiomyopathy than in ischemic cardiomyopathy (100% versus 86% versus 53%; P < 0.01). The prevalence of LAVAs adjacent to PN was higher in nonischemic cardiomyopathy than in ischemic cardiomyopathy (93% versus 27%; P < 0.001). Epicardial ablation was performed in 37 patients (76%). Epicardial LAVAs could not be eliminated because of the proximity to CAs or PN in 8 patients (18%). The epicardial electrophysiological VT substrate is often close to CAs and PN in patients with nonischemic cardiomyopathy. High-resolution image integration is potentially useful to minimize risks of PN and CA injury during epicardial VT ablation. © 2015 American Heart Association, Inc.
Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko
2012-06-01
Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Vascular liver anatomy and main variants: what the radiologist must know.
Seco, M; Donato, P; Costa, J; Bernardes, A; Caseiro-Alves, F
2010-01-01
Advances in surgical techniques are extremely demanding regarding the accuracy and level of detail expected for display of the vascular anatomy of the liver. Precise knowledge of the arterial, portal and hepatic vein territories are mandatory whenever a liver intervention is planned. Sectional anatomy can now be routinely performed on multidetector computed tomography (MDCT) with volumetric data and isotropic voxel display, by means of sub-millimetric slice thickness acquisition. The relevant vascular information can thus be gathered, reviewed and post-processed with unprecedented clarity, obviating the need for digital subtraction angiography. The scope of the present paper is to review the normal vascular liver anatomy, its most relevant variants including additional sources of vascular inflow. Apart from providing the surgeon with a detailed vascular and parenchymal roadmap knowledge of imaging findings may avoid potential confusion with pathologic processes.
Yuksekkaya, Ruken; Ozturk, Banu; Celikyay, Fatih; Sade, Recep; Kupeli, Mustafa; Yeginsu, Ali
2013-01-01
A bronchopleural fistula (BPF) is defined as a direct pathway between the bronchial tree or lung parenchyma and the pleural space. Herein, we describe the clinical findings and imaging results of BPFs in three cases. The patients' medical histories revealed that the first had recurrent pulmonary tuberculosis, the second had small-cell lung cancer (SCLC) and had previously undergone chemoradiotherapy, and the third had trauma. Multidetector computed tomography (MDCT) showed clear communication between the airways and pleural spaces which was sufficient for a proper diagnosis without performing a bronchoscopy. PMID:26029624
Multidetector Computer Tomography: Evaluation of Blunt Chest Trauma in Adults
Matos, António P.; Mascarenhas, Vasco; Herédia, Vasco
2014-01-01
Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall. PMID:25295188
Multidetector computer tomography: evaluation of blunt chest trauma in adults.
Palas, João; Matos, António P; Mascarenhas, Vasco; Herédia, Vasco; Ramalho, Miguel
2014-01-01
Imaging plays an essential part of chest trauma care. By definition, the employed imaging technique in the emergency setting should reach the correct diagnosis as fast as possible. In severe chest blunt trauma, multidetector computer tomography (MDCT) has become part of the initial workup, mainly due to its high sensitivity and diagnostic accuracy of the technique for the detection and characterization of thoracic injuries and also due to its wide availability in tertiary care centers. The aim of this paper is to review and illustrate a spectrum of characteristic MDCT findings of blunt traumatic injuries of the chest including the lungs, mediastinum, pleural space, and chest wall.
Diagnosis and classification of pancreatic and duodenal injuries in emergency radiology.
Linsenmaier, Ulrich; Wirth, Stefan; Reiser, Maximilian; Körner, Markus
2008-10-01
Pancreatic and duodenal injuries after blunt abdominal trauma are rare; however, delays in diagnosis and treatment can significantly increase morbidity and mortality. Multidetector computed tomography (CT) has a major role in early diagnosis of pancreatic and duodenal injuries. Detecting the often subtle signs of injury with whole-body CT can be difficult because this technique usually does not include a dedicated protocol for scanning the pancreas. Specific injury patterns in the pancreas and duodenum often have variable expression at early posttraumatic multidetector CT: They may be hardly visible, or there may be considerable exudate, hematomas, organ ruptures, or active bleeding. An accurate multidetector CT technique allows optimized detection of subtle abnormalities. In duodenal injuries, differentiation between a contusion of the duodenal wall or mural hematoma and a duodenal perforation is vital. In pancreatic injuries, determination of involvement of the pancreatic duct is essential. The latter conditions require immediate surgical intervention. Use of organ injury scales and a surgical classification adapted for multidetector CT enables classification of organ injuries for trauma scoring, treatment planning, and outcome control. In addition, multidetector CT reliably demonstrates potential complications of duodenal and pancreatic injuries, such as posttraumatic pancreatitis, pseudocysts, fistulas, exudates, and abscesses. (c) RSNA, 2008.
Meta-Analysis of Stress Myocardial Perfusion Imaging
2017-06-06
Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography
[Sigmoid endometriosis: a diagnostic dilemma on multidetector CT].
Telegrafo, Michele; Lorusso, Valentina; Rubini, Giuseppe; Rella, Leonarda; Pezzolla, Angela; Stabile Ianora, Amato Antonio; Moschetta, Marco
2013-01-01
Intestinal endometriosis represents a common condition that occurs particularly in women of reproductive age. The gastrointestinal tract is the third most common localization of endometriosis, after the ovaries and the peritoneum, and recto-sigmoid tract is involved in 70% of cases. Recto-sigmoid endometriosis has to be differentiated from other diseases of large bowel, especially in patients without a history of endometriosis. We report a case of sigmoid endometriosis which represented a diagnostic dilemma on multidetector computed tomography.
Wanner, Matthew R; Karmazyn, Boaz; Fan, Rong
2015-12-01
Hemobilia secondary to gallbladder polyposis is rare in children but has been reported in a few children with metachromatic leukodystrophy. We present a case with preoperative multidetector computed tomography (MDCT) diagnosis of massive hemobilia caused by gallbladder polyposis in a patient with metachromatic leukodystrophy. Our report highlights the importance of both awareness of the association of gallbladder polyposis with other syndromes such as metachromatic leukodystrophy as well as the possibility of this entity presenting with life-threatening bleeding.
Ikeda, Norihiko; Yoshimura, Akinobu; Hagiwara, Masaru; Akata, Soichi; Saji, Hisashi
2013-01-01
The number of minimally invasive operations, such as video-assisted thoracoscopic surgery (VATS) lobectomy or segmentectomy, has enormously increased in recent years. These operations require extreme knowledge of the anatomy of pulmonary vessels and bronchi in each patient, and surgeons must carefully dissect the branches of pulmonary vessels during operation. Thus, foreknowledge of the anatomy of each patient would greatly contribute to the safety and accuracy of the operation. The development of multi-detector computed tomography (MDCT) has promoted three dimensional (3D) images of lung structures. It is possible to see the vascular and bronchial structures from the view of the operator; therefore, it is employed for preoperative simulation as well as navigation during operation. Due to advances in software, even small vessels can be accurately imaged, which is useful in performing segmentectomy. Surgical simulation and navigation systems based on high quality 3D lung modeling, including vascular and bronchial structures, can be used routinely to enhance the safety operation, education of junior staff, as well as providing a greater sense of security to the operators.
Multidetector CT of blunt traumatic venous injuries in the chest, abdomen, and pelvis.
Holly, Brian P; Steenburg, Scott D
2011-01-01
Venous injuries as a result of blunt trauma are rare. Even though current protocols for multidetector computed tomography (CT) of patients with trauma are designed to evaluate primarily the solid organs and arteries, blunt venous injuries may nevertheless be identified, or at least suspected, on the basis of the multidetector CT findings. Venous injuries are associated with high morbidity and mortality rates. Diagnosis of a possible venous injury is crucial because the physical findings of a venous injury are nonspecific and may be absent. This article aims to make the radiologist aware of various venous injuries caused by blunt trauma and to provide helpful hints to aid in the identification of venous injuries. Multidetector CT technology, in combination with interactive manipulation of the raw dataset, can be useful in the creation of multiplanar reconstructed images and in the identification of a venous injury caused by blunt trauma. Familiarity with direct and indirect signs of venous injuries, as well as with examples of blunt traumatic venous injuries in the chest, abdomen, and pelvis, will help in the diagnosis of these injuries.
Koren Fernández, L; Alonso Charterina, S; Alcalá-Galiano Rubio, A; Sánchez Nistal, M A
2014-01-01
Pulmonary aspergillosis is a fungal infection usually caused by inhaling Aspergillus fumigatus spores. However, when we talk about aspergillosis, we normally refer to the spectrum of clinical and radiological findings that depend directly on the patient's immune status, on the prior existence of lung disease, and on the virulence of the infective organism. There are four types of pulmonary aspergillosis (aspergilloma, allergic bronchopulmonary aspergillosis, chronic necrotizing pulmonary aspergillosis, and invasive aspergillosis), and each type has its own distinct radiologic findings. We review the signs of pulmonary aspergillosis on multidetector computed tomography and we correlate them with patients' symptoms and immune responses. Likewise, we discuss the differential diagnoses. Copyright © 2013 SERAM. Published by Elsevier Espana. All rights reserved.
Montaudon, M; Desbarats, P; Berger, P; de Dietrich, G; Marthan, R; Laurent, F
2007-01-01
A thickened bronchial wall is the morphological substratum of most diseases of the airway. Theoretical and clinical models of bronchial morphometry have so far focused on bronchial lumen diameter, and bronchial length and angles, mainly assessed from bronchial casts. However, these models do not provide information on bronchial wall thickness. This paper reports in vivo values of cross-sectional wall area, lumen area, wall thickness and lumen diameter in ten healthy subjects as assessed by multi-detector computed tomography. A validated dedicated software package was used to measure these morphometric parameters up to the 14th bronchial generation, with respect to Weibel's model of bronchial morphometry, and up to the 12th according to Boyden's classification. Measured lumen diameters and homothety ratios were compared with theoretical values obtained from previously published studies, and no difference was found when considering dichotomic division of the bronchial tree. Mean wall area, lumen area, wall thickness and lumen diameter were then provided according to bronchial generation order, and mean homothety ratios were computed for wall area, lumen area and wall thickness as well as equations giving the mean value of each parameter for a given bronchial generation with respect to its value in generation 0 (trachea). Multi-detector computed tomography measurements of bronchial morphometric parameters may help to improve our knowledge of bronchial anatomy in vivo, our understanding of the pathophysiology of bronchial diseases and the evaluation of pharmacological effects on the bronchial wall. PMID:17919291
Targeted post-mortem computed tomography cardiac angiography: proof of concept.
Saunders, Sarah L; Morgan, Bruno; Raj, Vimal; Robinson, Claire E; Rutty, Guy N
2011-07-01
With the increasing use and availability of multi-detector computed tomography and magnetic resonance imaging in autopsy practice, there has been an international push towards the development of the so-called near virtual autopsy. However, currently, a significant obstacle to the consideration as to whether or not near virtual autopsies could one day replace the conventional invasive autopsy is the failure of post-mortem imaging to yield detailed information concerning the coronary arteries. To date, a cost-effective, practical solution to allow high throughput imaging has not been presented within the forensic literature. We present a proof of concept paper describing a simple, quick, cost-effective, manual, targeted in situ post-mortem cardiac angiography method using a minimally invasive approach, to be used with multi-detector computed tomography for high throughput cadaveric imaging which can be used in permanent or temporary mortuaries.
Stojanovska, Jadranka; Ibrahim, El-Sayed H.; Chughtai, Aamer R.; Jackson, Elizabeth A.; Gross, Barry H.; Jacobson, Jon A.; Tsodikov, Alexander; Daneshvar, Brian; Long, Benjamin D.; Chenevert, Thomas L.; Kazerooni, Ella A.
2017-01-01
Intrathoracic fat volume, more specifically, epicardial fat volume, is an emerging imaging biomarker of adverse cardiovascular events. The purpose of this work is to show the feasibility and reproducibility of intrathoracic fat volume measurement applied to contrast-enhanced multidetector computed tomography images. A retrospective cohort study of 62 subjects free of cardiovascular disease (55% females, age = 49 ± 11 years) conducted from 2008 to 2011 formed the study group. Intrathoracic fat volume was defined as all fat voxels measuring −50 to −250 Hounsfield Unit within the intrathoracic cavity from the level of the pulmonary artery bifurcation to the heart apex. The intrathoracic fat was separated into epicardial and extrapericardial fat by tracing the pericardium. The measurements were obtained by 2 readers and compared for interrater reproducibility. The fat volume measurements for the study group were 141 ± 72 cm3 for intrathoracic fat, 58 ± 27 cm3 for epicardial fat, and 84 ± 50 cm3 for extrapericardial fat. There was no statistically significant difference in intrathoracic fat volume measurements between the 2 readers, with correlation coefficients of 0.88 (P = .55) for intrathoracic fat volume and −0.12 (P = .33) for epicardial fat volume. Voxel-based measurement of intrathoracic fat, including the separation into epicardial and extrapericardial fat, is feasible and highly reproducible from multidetector computed tomography scans. PMID:28626797
Kim, Bo Ram; Lee, Jeong Min; Lee, Dong Ho; Yoon, Jeong Hee; Hur, Bo Yun; Suh, Kyung Suk; Yi, Nam-Joon; Lee, Kyung Boon; Han, Joon Koo
2017-10-01
Purpose To compare the diagnostic performance of gadoxetic acid-enhanced liver magnetic resonance (MR) imaging with that of contrast material-enhanced multidetector computed tomography (CT) in the detection of borderline hepatocellular nodules in patients with liver cirrhosis and to determine the Liver Imaging Reporting and Data System (LI-RADS) categories of these detected nodules. Materials and Methods The institutional review board approved this retrospective study and waived the informed consent requirement. Sixty-eight patients with pathologically proven dysplastic nodules (DNs) (low-grade DNs, n = 20; high-grade DNs, n = 17), early hepatocellular carcinomas (HCCs) (n = 42), or progressed HCCs (n = 33) underwent gadoxetic acid-enhanced MR imaging and multidetector CT. An additional 57 patients without any DNs or HCCs in the explanted livers were included as control subjects. Three radiologists independently graded the presence of liver nodules on a five-point confidence scale and assigned LI-RADS categories by using imaging findings. Jackknife alternative free-response receiver operating characteristics (JAFROC) software was used to compare the diagnostic accuracy of each modality in lesion detection. Results Reader-averaged figures of merit estimated with JAFROC software to detect hepatocellular nodules were 0.774 for multidetector CT and 0.842 for MR imaging (P = .002). Readers had significantly higher detection sensitivity for early HCCs with MR imaging than with multidetector CT (78.6% vs 52.4% [P = .001], 71.4% vs 50.0% [P = .011], and 73.8% vs 50.0% [P = .001], respectively). A high proportion of overall detected early HCCs at multidetector CT (59.4%) and MR imaging (72.3%) were categorized as LI-RADS category 4. Most early HCCs (76.2%) and high-grade DNs (82.4%) demonstrated hypointensity on hepatobiliary phase images. In total, 30 more LI-RADS category 4 early HCCs were identified with MR imaging than with multidetector CT across all readers. Conclusion Gadoxetic acid-enhanced MR imaging performed significantly better in the detection of high-risk borderline nodules, especially early HCCs, than did multidetector CT. © RSNA, 2017 Online supplemental material is available for this article.
Relationship between noise, dose, and pitch in cardiac multi-detector row CT.
Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G
2006-01-01
In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006
[The role of multidetector computer tomography in diagnosis of acute pancreatitis].
Lohanikhina, K Iu; Hordiienko, K P; Kozarenko, T M
2014-10-01
With the objective to improve the diagnostic semiotics of an acute pancreatitis (AP) 35 patients were examined, using 64-cut computeric tomograph Lightspeed VCT (GE, USA) with intravenous augmentation in arterial and portal phases. Basing on analysis of the investigations conducted, using multidetector computeric tomography (MDCT), the AP semiotics was systematized, which is characteristic for oedematous and destructive forms, diagnosed in 19 (44.2%) and 16 (45.8%) patients, accordingly. The procedure for estimation of preservation of the organ functional capacity in pancreonecrosis pres- ence was elaborated, promoting rising of the method diagnostic efficacy by 5.3 - 9.4%.
Cardiac Computed Tomography (Multidetector CT, or MDCT)
... other tests, such as chest X-rays , electrocardiograms (ECG) , echocardiograms (echocardiography) , or stress tests , don’t give ... be attached to your chest to monitor your ECG. The ECG is also needed to help the ...
Casula, E; Lonjedo, E; Cerverón, M J; Ruiz, A; Gómez, J
2014-01-01
The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment. The objective of this article is to review the cases of AAA in which CT angiography was the main imaging technique, so that radiologists will be able to detect the signs related to this disease, to diagnose it, to plan treatment, and to detect complications in the postoperative period. Copyright © 2012 SERAM. Published by Elsevier Espana. All rights reserved.
Evaluation of prosthetic valve thrombosis by 64-row multi-detector computed tomography. .
Tarzia, Vincenzo; Bortolussi, Giacomo; Rubino, Maurizio; Gallo, Michele; Bottio, Tomaso; Gerosa, Gino
2015-03-01
Multi-detector computed tomography (MDCT), combined with retrospective electrocardiographic gating, permits cardiac imaging with high accuracy. Recent advances in MDCT have seemed to respond adequately to the need for a non-invasive and reliable assessment of the coronary artery lumen. Two patients with prosthetic aortic valves (one bioprosthetic, one mechanical) presented at the authors' institution with dyspnea and syncopal episodes. MDCT was performed to evaluate thrombus characteristics and exclude coronary artery disease (CAD). Based on the MDCT coronary artery assessment, neither patient underwent preoperative invasive coronary angiography, abolishing the risk of any iatrogenic thrombus fragmentation and subsequent embolization. One patient underwent surgical treatment without complications, while medical therapy was successful in the other case. MDCT can be used for the accurate imaging of thrombi on prosthetic aortic valves, and to correctly assess possible CAD.
Diagnostic performance of 64-slice multidetector coronary computed tomographic angiography in women.
Jug, Borut; Gupta, Mohit; Papazian, Jenny; Li, Dong; Tsang, Janet; Bhatia, Harpreet; Karlsberg, Ronald; Budoff, Matthew
2012-12-01
Diagnostic approach to chest pain in women is challenging, but still under-investigated. The purpose of this study was to assess the diagnostic performance of 64-slice multidetector coronary computed tomographic angiography (CCTA) in women with chest pain. We included 606 patients--255 women and 351 men (mean age 61 ± 12 years for both)--who had been referred for a CCTA and an invasive coronary angiography (diagnostic standard) because of chest pain, either as part of clinical work-up in two urban medical centers or as part of the multicenter ACCURACY trial. On a patient-based model, the sensitivity, specificity, and positive predictive value (PPV) and negative predictive value to detect ≥50% and ≥70% stenosis were 98%, 84%, 87%, and 97% and 96%, 83%, 77%, and 97%, respectively, for women and 97%, 83%, 89%, and 95% and 94%, 91%, 90%, and 94%, respectively, for men. There were no statistically significant differences between men and women in diagnostic performance measures except for the PPV of detecting a ≥70% stenosis (P = .007). In women with chest pain, 64-slice multidetector CCTA is at least as sensitive and specific as in men. Our findings suggest that CCTA is a promising diagnostic tool for timely detection and/or exclusion of CAD in symptomatic intermediate-risk female populations.
Acute Perforated Diverticulitis: Assessment With Multidetector Computed Tomography.
Sessa, Barbara; Galluzzo, Michele; Ianniello, Stefania; Pinto, Antonio; Trinci, Margherita; Miele, Vittorio
2016-02-01
Colonic diverticulitis is a common condition in the western population. Complicated diverticulitis is defined as the presence of extraluminal air or abscess, peritonitis, colon occlusion, or fistulas. Multidetector row computed tomography (MDCT) is the modality of choice for the diagnosis and the staging of diverticulitis and its complications, which enables performing an accurate differential diagnosis and addressing the patients to a correct management. MDCT is accurate in diagnosing the site of perforation in approximately 85% of cases, by the detection of direct signs (focal bowel wall discontinuity, extraluminal gas, and extraluminal enteric contrast) and indirect signs, which are represented by segmental bowel wall thickening, abnormal bowel wall enhancement, perivisceral fat stranding of fluid, and abscess. MDCT is accurate in the differentiation from complicated colon diverticulitis and colon cancer, often with a similar imaging. The computed tomography-guided classification is recommended to discriminate patients with mild diverticulitis, generally treated with antibiotics, from those with severe diverticulitis with a large abscess, which may be drained with a percutaneous approach. Copyright © 2016 Elsevier Inc. All rights reserved.
Abernethy malformation with portal vein aneurysm in a child.
Chandrashekhara, Sheragaru H; Bhalla, Ashu Seith; Gupta, Arun Kumar; Vikash, C S; Kabra, Susheel Kumar
2011-01-01
Abernethy malformation is an extremely rare anomaly of the splanchnic venous system. We describe multidetector computed tomography findings of an incidentally detected Abernethy malformation with portal vein aneurysm in a two-and-half-year old child. The computed tomography scan was performed for the evaluation of respiratory distress, poor growth, and loss of appetite.
Yanagawa, Masahiro; Honda, Osamu; Kikuyama, Ayano; Gyobu, Tomoko; Sumikawa, Hiromitsu; Koyama, Mitsuhiro; Tomiyama, Noriyuki
2012-10-01
To evaluate the effects of ASIR on CAD system of pulmonary nodules using clinical routine-dose CT and lower-dose CT. Thirty-five patients (body mass index, 22.17 ± 4.37 kg/m(2)) were scanned by multidetector-row CT with tube currents (clinical routine-dose CT, automatically adjusted mA; lower-dose CT, 10 mA) and X-ray voltage (120 kVp). Each 0.625-mm-thick image was reconstructed at 0%-, 50%-, and 100%-ASIR: 0%-ASIR is reconstructed using only the filtered back-projection algorithm (FBP), while 100%-ASIR is reconstructed using the maximum ASIR and 50%-ASIR implies a blending of 50% FBP and ASIR. CAD output was compared retrospectively with the results of the reference standard which was established using a consensus panel of three radiologists. Data were analyzed using Bonferroni/Dunn's method. Radiation dose was calculated by multiplying dose-length product by conversion coefficient of 0.021. The consensus panel found 265 non-calcified nodules ≤ 30 mm (ground-glass opacity [GGO], 103; part-solid, 34; and solid, 128). CAD sensitivity was significantly higher at 100%-ASIR [clinical routine-dose CT, 71% (overall), 49% (GGO); lower-dose CT, 52% (overall), 67% (solid)] than at 0%-ASIR [clinical routine-dose CT, 54% (overall), 25% (GGO); lower-dose CT, 36% (overall), 50% (solid)] (p<0.001). Mean number of false-positive findings per examination was significantly higher at 100%-ASIR (clinical routine-dose CT, 8.5; lower-dose CT, 6.2) than at 0%-ASIR (clinical routine-dose CT, 4.6; lower-dose CT, 3.5; p<0.001). Effective doses were 10.77 ± 3.41 mSv in clinical routine-dose CT and 2.67 ± 0.17 mSv in lower-dose CT. CAD sensitivity at 100%-ASIR on lower-dose CT is almost equal to that at 0%-ASIR on clinical routine-dose CT. ASIR can increase CAD sensitivity despite increased false-positive findings. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Fayad, Laura M; Johnson, Pamela; Fishman, Elliot K
2005-01-01
Computed tomography (CT) plays an important role in the evaluation of musculoskeletal disease in the pediatric patient. With the advent of high-performance 16-section multidetector CT, images can be produced with subsecond gantry rotation times and with submillimeter acquisition, which yields true isotropic high-resolution volume data sets; these features are not attainable with older spiral CT technology. Such capabilities are particularly helpful in the evaluation of pediatric patients by virtually eliminating the need for sedation and minimizing dependence on patient cooperation. The role of three-dimensional (3D) volume imaging in the evaluation of pediatric musculoskeletal disease continues to evolve, with this technique becoming increasingly important in detection and characterization of lesions as well as in decisions about patient care. Specific designs and protocols for multidetector CT studies can be selected to minimize radiation dose to the patient. Principal clinical applications of 3D CT in evaluation of the pediatric musculoskeletal system include developmental abnormalities, trauma, neoplasms, and postoperative imaging.
Akpinar, Erhan; Türkbey, Bariş; Cil, Barbaros Erhan; Canyiğit, Murat; Dündar, Ziya; Balkanci, Ferhun
2007-06-01
Acute lower gastrointestinal system (GIS) bleeding is a life-threatening condition. Immediate determination of the origin of the bleeding is crucial, since hemostatic management must be initiated as rapidly as possible. Colonoscopy, radionuclide studies, and conventional angiography are considered the most important methods for assessing the origin of the bleeding. There are few published reports about the feasibility of computed tomography (CT) in acute GIS bleeding. We present multidetector CT (MDCT) findings in a case of Hodgkin disease status one month post-chemotherapy (CHOP protocol; cyclophosphamide, doxorubicin, vincristine, prednisone) that presented with acute lower GIS bleeding.
Akiba, Tadashi; Marushima, Hideki; Harada, Junta; Kobayashi, Susumu; Morikawa, Toshiaki
2009-01-01
Video-assisted thoracic surgery (VATS) has recently been adopted for complicated anatomical lung resections. During these thoracoscopic procedures, surgeons view the operative field on a two-dimensional (2-D) video monitor and cannot palpate the organ directly, thus frequently encountering anatomical difficulties. This study aimed to estimate the usefulness of preoperative three-dimensional (3-D) imaging of thoracic organs. We compared the preoperative 64-row three-dimensional multidetector computed tomography (3DMDCT) findings of lung cancer-affected thoracic organs to the operative findings. In comparison to the operative findings, the branches of pulmonary arteries, veins, and bronchi were well defined in the 3D-MDCT images of 27 patients. 3D-MDCT imaging is useful for preoperatively understanding the individual thoracic anatomy in lung cancer surgery. This modality can therefore contribute to safer anatomical pulmonary operations, especially in VATS.
de Weerd, Louis; Weum, Sven; Mercer, James B
2009-09-01
The aim of this paper is to evaluate dynamic infrared thermography (DIRT) as a technique to assist in preoperative perforator selection and planning of free deep inferior epigastric perforator (DIEP) flaps. Twenty-seven patients, scheduled for secondary autologous breast reconstruction with either a free DIEP flap or superficial inferior epigastric artery flap, were included in this prospective clinical study. Preoperative mapping of perforators was performed with a hand-held Doppler and DIRT. A multidetector computer tomography scan was additionally carried out in the last 8 patients. In 23 patients a DIEP flap was used. The perforator as selected from DIRT was a suitable perforator in all DIEP flaps. The location and quality of the selected perforator from DIRT corresponded well with the multidetector computer tomography scan results. Preoperative perforator selection and planning of DIEP flaps is facilitated with the use of DIRT. The technique is noninvasive and easy to use.
Abernethy malformation with portal vein aneurysm in a child
Chandrashekhara, Sheragaru H.; Bhalla, Ashu Seith; Gupta, Arun Kumar; Vikash, C. S.; Kabra, Susheel Kumar
2011-01-01
Abernethy malformation is an extremely rare anomaly of the splanchnic venous system. We describe multidetector computed tomography findings of an incidentally detected Abernethy malformation with portal vein aneurysm in a two-and-half-year old child. The computed tomography scan was performed for the evaluation of respiratory distress, poor growth, and loss of appetite. PMID:21430844
T staging of gastric cancer: role of multi-detector row CT.
Kumano, Seishi; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Iannaccone, Riccardo; Nakata, Saki; Onishi, Hiromitsu; Osuga, Keigo; Tomoda, Kaname; Catalano, Carlo; Nakamura, Hironobu
2005-12-01
To evaluate retrospectively the accuracy of multi-detector row computed tomography (CT) in the assessment of serosal invasion in patients with gastric cancer. The Ethics Committee does not require approval or informed consent for retrospective studies. Forty-one consecutive patients (24 men, 17 women; mean age, 68 years) with gastric cancer were included in this study. All patients were given 600 mL of tap water to drink and were positioned prone or supine on the scanning table. The detector row configuration included four detector rows, a section thickness of 1.25 mm, a pitch of 6, and a reconstruction interval of 0.63 mm. Transverse and multiplanar reconstruction images were simultaneously evaluated by two independent observers to assess the depth of tumor invasion in the gastric wall (ie, T stage). T staging at multi-detector row CT was compared with T staging at histologic evaluation (reference standard), which was performed by means of surgical or histologic examination of the resected specimen. We also calculated the sensitivity, specificity, and accuracy of multi-detector row CT for each observer in the assessment of serosal invasion. Analysis of interobserver agreement showed substantial or almost perfect agreement (nonweighted kappa value of 0.78 and weighted kappa value of 0.85). Correct assessment of gastric wall invasion was 80% and 85% for observers 1 and 2, respectively. The sensitivity, specificity, and accuracy of multi-detector row CT in the assessment of serosal invasion were 90%, 95%, and 93%, respectively, for observer 1 and 80%, 97%, and 93%, respectively, for observer 2. Overstaging occurred in six patients, and understaging occurred in five patients. All understaged tumors were scirrhous subtype gastric cancer. Multi-detector row CT scanning of patients with gastric cancer gave 93% accuracy in the assessment of serosal invasion in patients with gastric cancer. RSNA, 2005
Tack, Denis; Jahnen, Andreas; Kohler, Sarah; Harpes, Nico; De Maertelaer, Viviane; Back, Carlo; Gevenois, Pierre Alain
2014-01-01
To report short- and long-term effects of an audit process intended to optimise the radiation dose from multidetector row computed tomography (MDCT). A survey of radiation dose from all eight MDCT departments in the state of Luxembourg performed in 2007 served as baseline, and involved the most frequently imaged regions (head, sinus, cervical spine, thorax, abdomen, and lumbar spine). CT dose index volume (CTDIvol), dose-length product per acquisition (DLP/acq), and DLP per examination (DLP/exa) were recorded, and their mean, median, 25th and 75th percentiles compared. In 2008, an audit conducted in each department helped to optimise doses. In 2009 and 2010, two further surveys evaluated the audit's impact on the dose delivered. Between 2007 and 2009, DLP/exa significantly decreased by 32-69 % for all regions (P < 0.001) except the lumbar spine (5 %, P = 0.455). Between 2009 and 2010, DLP/exa significantly decreased by 13-18 % for sinus, cervical and lumbar spine (P ranging from 0.016 to less than 0.001). Between 2007 and 2010, DLP/exa significantly decreased for all regions (18-75 %, P < 0.001). Collective dose decreased by 30 % and the 75th percentile (diagnostic reference level, DRL) by 20-78 %. The audit process resulted in long-lasting dose reduction, with DRLs reduced by 20-78 %, mean DLP/examination by 18-75 %, and collective dose by 30 %. • External support through clinical audit may optimise default parameters of routine CT. • Reduction of 75th percentiles used as reference diagnostic levels is 18-75 %. • The effect of this audit is sustainable over time. • Dose savings through optimisation can be added to those achievable through CT.
Ye, Feng; Liu, Jun; Ouyang, Han
2015-08-01
The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.
Use of multidetector computed tomography in the assessment of dogs with pericardial effusion.
Scollan, K F; Bottorff, B; Stieger-Vanegas, S; Nemanic, S; Sisson, D
2015-01-01
Contrast-enhanced multidetector computed tomography (MDCT) allows high spatial and temporal resolution imaging of cardiac, thoracic, and abdominal structures. Accurate determination of the cause of pericardial effusion (PE) is essential to providing appropriate treatment and prognosis. Echocardiography and pericardial fluid analysis may not differentiate between causes of PE and cannot identify extracardiac metastasis. Describe the thoracic and abdominal MDCT findings and evaluate the utility of MDCT to differentiate between neoplastic and nonneoplastic causes of PE in dogs. Eleven client-owned dogs with PE diagnosed by echocardiography. Prospective observational study. Transthoracic echocardiography (TTE), 3-view thoracic radiography, and contrast-enhanced thoracic and abdominal MDCT images were evaluated for the presence of cardiac masses, pulmonary metastases, and abdominal masses. Histopathology in 5 dogs and survival analysis in all dogs were evaluated. A neoplastic cause was identified in 6/11 dogs and a nonneoplastic cause was identified in 5/11. Cardiac MDCT findings were consistent with TTE findings in all dogs with right atrial (5/5) and heart base masses (1/1). Pulmonary metastases were identified in 1/11 dogs by thoracic radiography and in 2/11 dogs by MDCT. MDCT identified splenic or hepatic lesions consistent with neoplasia in 6/11 and 5/11 dogs, respectively. Focal MDCT pericardial changes at the pericardiocentesis site were noted in 3/11 dogs. Multidetector computed tomography did not improve the detection of cardiac masses in dogs with PE over echocardiography. The benefit of MDCT was primarily in the detection of pulmonary metastases and extracardiac lesions using a single imaging modality. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Omura, Kensuke; Ota, Hideki; Takahashi, Yuuki; Matsuura, Tomonori; Seiji, Kazumasa; Arai, Yoichi; Morimoto, Ryo; Satoh, Fumitoshi; Takase, Kei
2017-03-01
Adrenal venous sampling is the most reliable diagnostic procedure to determine surgical indications in primary aldosteronism. Because guidelines recommend multidetector computed tomography (CT) to evaluate the adrenal gland, some past reports used multidetector CT as a guide for adrenal venous sampling. However, the detailed anatomy of the right adrenal vein and its relationship with an accessory hepatic vein remains uncertain. The purpose of this study was to describe detailed anatomical variations of the right adrenal vein and to determine the concordance between CT and catheter venography in patients with primary aldosteronism. In total, 440 consecutive patients who underwent adrenal venous sampling were included. Four-phase dynamic CT was performed. Anatomical locations and variations of the right adrenal vein and its relationship with the accessory hepatic vein were compared with catheter venographic findings. Successful catheterization was achieved in 437 patients (99%). The right adrenal vein was visualized in the late arterial phase with CT in 420 patients (95%). The right adrenal vein formed a common trunk with the accessory hepatic vein in 87 patients (20%). CT identified the correct craniocaudal level of the orifice in 354 patients (84%). Anatomical variations, location, and angle of inflow of the right adrenal vein based on CT demonstrated high concordance with catheter venography. CT may provide useful information for preparation before adrenal venous sampling. © 2017 American Heart Association, Inc.
Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E
2016-09-01
The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.
NASA Astrophysics Data System (ADS)
Tarasov, A. P.; Egorov, A. I.; Rogatkin, D. A.
2017-07-01
Using multidetector computed tomography, thicknesses of bone squame and soft tissues of human head were assessed. MC simulation revealed impropriety of source-detector separation distances for 3 oximeters, which can cause extracerebral contamination.
Characterization of the Left-Sided Substrate in Arrhythmogenic Right Ventricular Cardiomyopathy.
Berte, Benjamin; Denis, Arnaud; Amraoui, Sana; Yamashita, Seigo; Komatsu, Yuki; Pillois, Xavier; Sacher, Frédéric; Mahida, Saagar; Wielandts, Jean-Yves; Sellal, Jean-Marc; Frontera, Antonio; Al Jefairi, Nora; Derval, Nicolas; Montaudon, Michel; Laurent, François; Hocini, Mélèze; Haïssaguerre, Michel; Jaïs, Pierre; Cochet, Hubert
2015-12-01
The correlates of left ventricular (LV) substrate in arrhythmogenic right ventricular (RV) cardiomyopathy are largely unknown. Thirty-two patients with arrhythmogenic RV cardiomyopathy (47±14 years; 6 women) were included. RV and LV dysplasia were defined from multidetector computed tomography and cardiac magnetic resonance imaging. Arrhythmias were characterized as right-sided or left-sided on 12-lead ECG recordings at baseline and during isoproterenol testing. In 14 patients, the imaging substrate was compared with voltage mapping and local abnormal ventricular activity. Imaging abnormalities were found in 32 (100%) and 21 (66%) patients on the RV and LV, respectively, intramyocardial fat on multidetector computed tomography being the most sensitive feature. LV involvement related to none of the Task Force criteria. Right-sided arrhythmias were more frequent than left-sided arrhythmias (P=0.003) although the latter were more frequent in case of LV involvement (P=0.02). The agreement between low voltage and fat on multidetector computed tomography was high on the RV when using either endocardial unipolar or epicardial bipolar data (κ=0.82 and κ=0.78, respectively) but lower on the LV (κ=0.54 for epicardial bipolar). LV local abnormal ventricular activity was found in all patients with LV involvement, and none of the others. The density of local abnormal ventricular activity within fat areas was similar between the RV and LV (P=0.57). LV substrate is frequent in arrhythmogenic RV cardiomyopathy, but poorly identified by current diagnostic strategies. Left-sided arrhythmias are more frequent in case of LV involvement. LV fat hosts the same density of local abnormal ventricular activity as RV fat, but is less efficiently detected by voltage mapping. These results support the need for alternative diagnostic strategies to identify LV dysplasia. © 2015 American Heart Association, Inc.
Solomon, Justin; Mileto, Achille; Nelson, Rendon C; Roy Choudhury, Kingshuk; Samei, Ehsan
2016-04-01
To determine if radiation dose and reconstruction algorithm affect the computer-based extraction and analysis of quantitative imaging features in lung nodules, liver lesions, and renal stones at multi-detector row computed tomography (CT). Retrospective analysis of data from a prospective, multicenter, HIPAA-compliant, institutional review board-approved clinical trial was performed by extracting 23 quantitative imaging features (size, shape, attenuation, edge sharpness, pixel value distribution, and texture) of lesions on multi-detector row CT images of 20 adult patients (14 men, six women; mean age, 63 years; range, 38-72 years) referred for known or suspected focal liver lesions, lung nodules, or kidney stones. Data were acquired between September 2011 and April 2012. All multi-detector row CT scans were performed at two different radiation dose levels; images were reconstructed with filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction (MBIR) algorithms. A linear mixed-effects model was used to assess the effect of radiation dose and reconstruction algorithm on extracted features. Among the 23 imaging features assessed, radiation dose had a significant effect on five, three, and four of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Adaptive statistical iterative reconstruction had a significant effect on three, one, and one of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). MBIR reconstruction had a significant effect on nine, 11, and 15 of the features for liver lesions, lung nodules, and renal stones, respectively (P < .002 for all comparisons). Of note, the measured size of lung nodules and renal stones with MBIR was significantly different than those for the other two algorithms (P < .002 for all comparisons). Although lesion texture was significantly affected by the reconstruction algorithm used (average of 3.33 features affected by MBIR throughout lesion types; P < .002, for all comparisons), no significant effect of the radiation dose setting was observed for all but one of the texture features (P = .002-.998). Radiation dose settings and reconstruction algorithms affect the extraction and analysis of quantitative imaging features in lesions at multi-detector row CT.
2014-01-01
Background Single-pass, contrast-enhanced whole body multidetector computed tomography (MDCT) emerged as the diagnostic standard for evaluating patients with major trauma. Modern iterative image algorithms showed high image quality at a much lower radiation dose in the non-trauma setting. This study aims at investigating whether the radiation dose can safely be reduced in trauma patients without compromising the diagnostic accuracy and image quality. Methods/Design Prospective observational study with two consecutive cohorts of patients. Setting: A high-volume, academic, supra-regional trauma centre in Germany. Study population: Consecutive male and female patients who 1. had been exposed to a high-velocity trauma mechanism, 2. present with clinical evidence or high suspicion of multiple trauma (predicted Injury Severity Score [ISS] ≥16) and 3. are scheduled for primary MDCT based on the decision of the trauma leader on call. Imaging protocols: In a before/after design, a consecutive series of 500 patients will undergo single-pass, whole-body 128-row multi-detector computed tomography (MDCT) with a standard, as low as possible radiation dose. This will be followed by a consecutive series of 500 patients undergoing an approved ultra-low dose MDCT protocol using an image processing algorithm. Data: Routine administrative data and electronic patient records, as well as digital images stored in a picture archiving and communications system will serve as the primary data source. The protocol was approved by the institutional review board. Main outcomes: (1) incidence of delayed diagnoses, (2) diagnostic accuracy, as correlated to the reference standard of a synopsis of all subsequent clinical, imaging, surgical and autopsy findings, (3) patients’ safety, (4) radiation exposure (e.g. effective dose), (5) subjective image quality (assessed independently radiologists and trauma surgeons on a 100-mm visual analogue scale), (6) objective image quality (e.g., contrast-to-noise ratio). Analysis: Multivariate regression will be employed to adjust and correct the findings for time and cohort effects. An exploratory interim analysis halfway after introduction of low-dose MDCT will be conducted to assess whether this protocol is clearly inferior or superior to the current standard. Discussion Although non-experimental, this study will generate first large-scale data on the utility of imaging-enhancing algorithms in whole-body MDCT for major blunt trauma. Trial registration Current Controlled Trials ISRCTN74557102. PMID:24589310
Arslan, Harun; Fatih Özbay, Mehmet; Çallı, İskan; Doğan, Erkan; Çelik, Sebahattin; Batur, Abdussamet; Bora, Aydın; Yavuz, Alpaslan; Bulut, Mehmet Deniz; Özgökçe, Mesut; Çetin Kotan, Mehmet
2017-03-01
Diagnostic performance of Diffusion-Weighted magnetic resonance Imaging (DWI) and Multi-Detector Computed Tomography (MDCT) for TNM (Tumor, Lymph node, Metastasis) staging of gastric cancer was compared. We used axial T2-weighted images and DWI (b-0,400 and b-800 s/mm2) protocol on 51 pre-operative patients who had been diagnosed with gastric cancer. We also conducted MDCT examinations on them. We looked for a signal increase in the series of DWI images. The depth of tumor invasion in the stomach wall (tumor (T) staging), the involvement of lymph nodes (nodal (N) staging), and the presence or absence of metastases (metastatic staging) in DWI and CT images according to the TNM staging system were evaluated. In each diagnosis of the tumors, sensitivity, specificity, positive and negative accuracy rates of DWI and MDCT examinations were found through a comparison with the results of the surgical pathology, which is the gold standard method. In addition to the compatibilities of each examination with surgical pathology, kappa statistics were used. Sensitivity and specificity of DWI and MDCT in lymph node staging were as follows: N1: DWI: 75.0%, 84.6%; MDCT: 66.7%, 82%;N2: DWI: 79.3%, 77.3%; MDCT: 69.0%, 68.2%; N3: DWI: 60.0%, 97.6%; MDCT: 50.0%, 90.2%. The diagnostic tool DWI seemed more compatible with the gold standard method (surgical pathology), especially in the staging of lymph node, when compared to MDCT. On the other hand, in T staging, the results of DWI and MDCT were better than the gold standard when the T stage increased. However, DWI did not demonstrate superiority to MDCT. The sensitivity and specificity of both imaging techniques for detecting distant metastasis were 100%. The diagnostic accuracy of DWI for TNM staging in gastric cancer before surgery is at a comparable level with MDCT and adding DWI to routine protocol of evaluating lymph nodes metastasis might increase diagnostic accuracy.
[Evaluation of cardiac tumors by multidetector computed tomography and magnetic resonance imaging].
Mercado-Guzman, Marcela P; Meléndez-Ramírez, Gabriela; Castillo-Castellon, Francisco; Kimura-Hayama, Eric
Cardiac tumors, are a rare pathology (0.002-0.3%) in all age groups, however, they have a clinic importance, due the affected organ. They are classified in primary (benign or malignant) and secondary (metastasis) types. Among primary type, mixoma, is the most common benign tumor, and sarcoma represents most of the malignant injuries. Cardiac metastasis are more frequent than primary tumors. Clinic effects of cardiac tumors are unspecific and vary according their location, size and agresivity. The use of Multidetector Computed Tomography (MDCT) and Magnetic Resonance Imaging (MRI) assist on the location, sizing, anatomical relationships and the compromise of adyacents structures, besides, MRI is useful for tissue characterization of the tumor. Due to the previous reasons, studies based on noninvasive cardiovascular imaging, have an important role on the characterization of these lesions and the differential diagnosis among them. Copyright © 2016 Instituto Nacional de Cardiología Ignacio Chávez. Publicado por Masson Doyma México S.A. All rights reserved.
Jones, Blake C; Lipson, Evan J; Childers, Brandon; Fishman, Elliot K; Johnson, Pamela T
The incidence of melanoma has risen dramatically over the past several decades. Oncologists rely on the ability of radiologists to identify subtle radiographic changes representing metastatic and recurrent melanoma in uncommon locations on multidetector computed tomography (MDCT) as the front-line imaging surveillance tool. To accomplish this goal, MDCT acquisition and display must be optimized and radiologist interpretation and search patterns must be tailored to identify the unique and often subtle metastatic lesions of melanoma. This article describes MDCT acquisition and display techniques that optimize the visibility of melanoma lesions, such as high-contrast display windows and multiplanar reconstructions. In addition, innovative therapies for melanoma, such as immunotherapy and small-molecule therapy, have altered clinical management and outcomes and have also changed the spectrum of therapeutic complications that can be detected on MDCT. Recent advances in melanoma therapy and potential complications that the radiologist can identify on MDCT are reviewed.
[Application of medical imaging to general thoracic surgery].
Oizumi, Hiroyuki
2014-07-01
Medical imaging technology is rapidly progressing. Positron emission tomography (PET) has played major role in the staging and choice of treatment modality in lung cancer patients. Magnetic resonance imaging (MRI) is now routinely used for mediastinal tumors and the use of diffusion-weighted images (DWI) may help in the diagnosis of malignancies including lung cancers. The benefits of medical imaging technology are not limited to diagnostics, and include simulation or navigation for complex lung resection and other procedures. Multidetector row computed tomography (MDCT) shortens imaging time to obtain detailed and precise volume data, which improves diagnosis of small-sized lung cancers. 3-dimensional reconstruction of the volume data allows the safe performance of thoracoscopic surgery. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. For lung segmentectomy, visualization of venous branches in the affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. Therefore, the application of medical imaging technology is useful in general thoracic surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xiaohua; Yuan, Huishu; Duan, Jianghui
2013-08-15
Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lungmore » function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.« less
Multidetector CT evaluation of the postoperative pancreas.
Yamauchi, Fernando I; Ortega, Cinthia D; Blasbalg, Roberto; Rocha, Manoel S; Jukemura, José; Cerri, Giovanni G
2012-01-01
Several pancreatic diseases may require surgical treatment, with most of these procedures classified as resection or drainage. Resection procedures, which are usually performed to remove pancreatic tumors, include pancreatoduodenectomy, central pancreatectomy, distal pancreatectomy, and total pancreatectomy. Drainage procedures are usually performed to treat chronic pancreatitis after the failure of medical therapy and include the Puestow and Frey procedures. The type of surgery depends not only on the patient's symptoms and the location of the disease, but also on the expertise of the surgeon. Radiologists should become familiar with these surgical procedures to better understand postoperative changes in anatomic findings. Multidetector computed tomography is the modality of choice for identifying normal findings after surgery, postoperative complications, and tumor recurrence in patients who have undergone pancreatic surgery. RSNA, 2012
Gupta, Rajiv; Jones, Stephen E; Mooyaart, Eline A Q; Pomerantz, Stuart R
2006-06-01
The development of multidetector row computed tomography (MDCT) now permits visualization of the entire vascular tree that is relevant for the management of stroke within 15 seconds. Advances in MDCT have brought computed tomography angiography (CTA) to the frontline in evaluation of stroke. CTA is a rapid and noninvasive modality for evaluating the neurovasculature. This article describes the role of CTA in the management of stroke. Fundamentals of contrast delivery, common pathologic findings, artifacts, and pitfalls in CTA interpretation are discussed.
Neubauer, Jakob; Benndorf, Matthias; Lang, Hannah; Lampert, Florian; Kemna, Lars; Konstantinidis, Lukas; Neubauer, Claudia; Reising, Kilian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Goerke, Sebastian M
2015-08-01
To compare the visualization of cortical fractures, cortical defects, and orthopedic screws in a dedicated extremity flat-panel computed tomography (FPCT) scanner and a multidetector computed tomography (MDCT) scanner.We used feet of European roe deer as phantoms for cortical fractures, cortical defects, and implanted orthopedic screws. FPCT and MDCT scans were performed with equivalent dose settings. Six observers rated the scans according to number of fragments, size of defects, size of defects opposite orthopedic screws, and the length of different screws. The image quality regarding depiction of the cortical bone was assessed. The gold standard (real number of fragments) was evaluated by autopsy.The correlation of reader assessment of fragments, cortical defects, and screws with the gold standard was similar for FPCT and MDCT. Three readers rated the subjective image quality of the MDCT to be higher, whereas the others showed no preferences.Although the image quality was rated higher in the MDCT than in the FPCT by 3 out of 6 observers, both modalities proved to be comparable regarding the visualization of cortical fractures, cortical defects, and orthopedic screws and of use to musculoskeletal radiology regarding fracture detection and postsurgical evaluation in our experimental setting.
Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis
2007-02-01
To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P < .001) compared with the anatomic reference standard. Ninety-five percent of the differences between CT arthrography and anatomic values ranged from -1.34 to 0.74 mm. The difference between mean cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P < .001). Changes in cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.
López-Ramírez, M A; Lever-Rosas, C D; Motta-Ramírez, G A; Rebollo-Hurtado, V; Guzmán-Bárcenas, J; Fonseca-Morales, J V; Carreño-Lomeli, M A
In relation to the number of new cases diagnosed, gastric cancer is the fourth most common cancer worldwide, and the second cause of cancer death. The development of multidetector tomography has improved the preoperative staging of gastric cancer. To correlate preoperative tomographic studies with the definitive pathologic results according to the TNM staging system. A retrospective, cross-sectional study within the time frame of January 2009 to December 2013 was conducted that included the case records of 67 patients. They all had upper endoscopy and preoperative multidetector tomography examinations, underwent surgical resection, and had the corresponding histopathology study. Statistical analysis was carried out with the SPSS version 15.0 software and the sensitivity and specificity calculations were made using the Excel 2011 program for Mac. The majority of the patients included in the case series had clinical stage iii and iv disease. When compared with the histopathologic result, the overall accuracy of multidetector CT was 83% (T0 96%, T1 94%, T2 93%, T3 67%, and T4 67%) for tumor size (T) and was 70% (N0 72%, N1 73%, N2 70%, and N3 66%) for lymph node involvement (N). Overall sensitivity was 48% (T0 100%, T1 0%, T2 33%, T3 44%, and T4 65%) for T and was 41% (N0 58%, N1 56%, N2 15%, and N3 35%) for N. A strong association between the multidetector CT results and the pathology results was demonstrated through the Spearman's correlation, especially in T4 and N3. Multidetector computed tomography showed greater congruency in detecting stages T4, N0, and N3 in gastric cancer, when compared with the definitive histopathologic results. Copyright © 2017 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.
Basak, Muzaffer; Ozkurt, Huseyin; Tanriverdi, Orhan; Cay, Esra; Aydin, Mustafa; Miroglu, Cengiz
2009-01-01
The purpose of this study was to evaluate the use of virtual cystoscopy performed with multidetector computed tomography (CT) in patients with suspected bladder tumors and histories of bladder carcinoma operation. Thirty-six patients (29 men and 7 women) with a mean age of 66 years (range, 24-88 years) with suspected bladder tumors and histories of bladder carcinoma operation were included in this prospective study. Virtual cystoscopy was performed by 16-slice multidetector CT scanner. The bladder was filled with diluted contrast material solution through a Foley catheter. Then, all patients underwent conventional cystoscopy examination. Two reviewers found 18 lesions detected by virtual cystoscopy by consensus, whereas 19 lesions were depicted by conventional cystoscopy. At virtual and conventional cystoscopies, the conditions of 3 patients, 2 with chronic inflammations and 1 with foreign body reaction, were wrongly diagnosed as tumors. At conventional cystoscopy, one patient's result was wrongly interpreted as normal. In pathologic evaluation, all tumors were diagnosed as transitional cell carcinoma. Bladder tumor can be noninvasively diagnosed using virtual cystoscopy. Use of virtual cystoscopy should be considered inpatients who present with hematuria or have histories of bladder carcinoma operation and are for follow-up because of its lesser complication risk and its being a less invasive, easily applied procedure without need of anesthesia. In the future, owing to the development of the CT technology and image processing technique, virtual cystoscopy may have a part in the detection of bladder cancer.
Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro
2010-08-01
To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.
NASA Astrophysics Data System (ADS)
Belinato, W.; Santos, W. S.; Paschoal, C. M. M.; Souza, D. N.
2015-06-01
The combination of positron emission tomography (PET) and computed tomography (CT) has been extensively used in oncology for diagnosis and staging of tumors, radiotherapy planning and follow-up of patients with cancer, as well as in cardiology and neurology. This study determines by the Monte Carlo method the internal organ dose deposition for computational phantoms created by multidetector CT (MDCT) beams of two PET/CT devices operating with different parameters. The different MDCT beam parameters were largely related to the total filtration that provides a beam energetic change inside the gantry. This parameter was determined experimentally with the Accu-Gold Radcal measurement system. The experimental values of the total filtration were included in the simulations of two MCNPX code scenarios. The absorbed organ doses obtained in MASH and FASH phantoms indicate that bowtie filter geometry and the energy of the X-ray beam have significant influence on the results, although this influence can be compensated by adjusting other variables such as the tube current-time product (mAs) and pitch during PET/CT procedures.
Facenda, Catherine; Vaz, Nuno; Castañeda, Edgar Augusto; del Amo, Montserrat; Garcia-Diez, Ana Isabel; Pomes, Jaime
2017-01-01
Blunt injuries to the chest wall are an important chapter on emergency room (ER) departments, being the third most common injuries in trauma patients which ominous complications could appear. This article describes different types of traumatic events affecting the chest wall, which maybe misdiagnosed with conventional X-ray. Special emphasis has been done in computed tomography (CT) and multidetector CT (MDCT) imaging. This technique is considered the “gold-standard” for those traumatic patients, due to its fast acquisition covering the whole area of interest in axial plane, reconstructing multiplanar (2D, 3D) volume-rendered images with a superb quality and angiographic CT capabilities for evaluating vascular damage. Complementary techniques such as ultrasonography (US) and magnetic resonance imaging (MRI) may improve the diagnostic accuracy due to its great capacity in visualising soft-tissue trauma (muscle-tendinous tears) and subtle fractures. All these imaging methods have an important role in quantifying the severity of chest wall trauma. The findings of this study have been exposed with cases of our archives in a didactic way. PMID:28932697
Keles, Papatya; Yuce, Ihsan; Keles, Sait; Kantarci, Mecit
2016-06-01
The aim of this study was to define the different courses and percentages of hepatic artery that were detected during preoperative evaluation of living liver donors by multidetector computed tomographic angiography (MDCTA). We evaluated 150 donors before hepatic transplantation. All of the donors were evaluated by multislice CT scan with 256 detectors. For each patient, arterial, portal and venous phase images were obtained. The hepatic arterial variations were evaluated by the same radiologist according to Michels' classification. Common hepatic arterial anatomy (type I) was observed in 95 donors (63.3%). Other arterial variations were determined in the remaining 55 donors (36.6%). The second common variation was type XI which did not match with the description of Michels' classification variation in 15 donors (10%). The remaining variations described in Michels' classification were seen at lower rates. Type VII or X variation was not seen. MDCTA is a useful method to identify the blood supply of the liver before the liver transplantations, and surgeons can make their plan on the basis of CT data.
Lee, Sun Hee; Jung, Ji Mi; Song, Min Seob; Choi, Seok jin; Chung, Woo Yeong
2013-08-01
Turner syndrome is well known to be associated with significant cardiovascular abnormalities. This paper studied the incidence of cardiovascular abnormalities in asymptomatic adolescent patients with Turner syndrome using multidetector computed tomography (MDCT) instead of echocardiography. Twenty subjects diagnosed with Turner syndrome who had no cardiac symptoms were included. Blood pressure and electrocardiography (ECG) was checked. Cardiovascular abnormalities were checked by MDCT. According to the ECG results, 11 had a prolonged QTc interval, 5 had a posterior fascicular block, 3 had a ventricular conduction disorder. MDCT revealed vascular abnormalities in 13 patients (65%). Three patients had an aberrant right subclavian artery, 2 had dilatation of left subclavian artery, and others had an aortic root dilatation, aortic diverticulum, and abnormal left vertebral artery. As for venous abnormalities, 3 patients had partial anomalous pulmonary venous return and 2 had a persistent left superior vena cava. This study found cardiovascular abnormalities in 65% of asymptomatic Turner syndrome patients using MDCT. Even though, there are no cardiac symptoms in Turner syndrome patients, a complete evaluation of the heart with echocardiography or MDCT at transition period to adults must be performed.
Park, Ko Woon; Kim, Seong Hyun; Choi, Seong Ho; Lee, Won Jae
2010-01-01
To evaluate useful computed tomographic features to differentiate nonneoplastic and neoplastic gallbladder polyps 1 cm or bigger. Thirty-one patients with 32 nonneoplastic polyps and 67 patients with 73 neoplastic polyps 1 cm or bigger underwent unenhanced and dual-phase (arterial and portal venous phases) multi-detector row computed tomography. Gallbladder polyps were diagnosed by cholecystectomy. Computed tomographic features including size (
Dodd, Lori E; Wagner, Robert F; Armato, Samuel G; McNitt-Gray, Michael F; Beiden, Sergey; Chan, Heang-Ping; Gur, David; McLennan, Geoffrey; Metz, Charles E; Petrick, Nicholas; Sahiner, Berkman; Sayre, Jim
2004-04-01
Cancer of the lung and bronchus is the leading fatal malignancy in the United States. Five-year survival is low, but treatment of early stage disease considerably improves chances of survival. Advances in multidetector-row computed tomography technology provide detection of smaller lung nodules and offer a potentially effective screening tool. The large number of images per exam, however, requires considerable radiologist time for interpretation and is an impediment to clinical throughput. Thus, computer-aided diagnosis (CAD) methods are needed to assist radiologists with their decision making. To promote the development of CAD methods, the National Cancer Institute formed the Lung Image Database Consortium (LIDC). The LIDC is charged with developing the consensus and standards necessary to create an image database of multidetector-row computed tomography lung images as a resource for CAD researchers. To develop such a prospective database, its potential uses must be anticipated. The ultimate applications will influence the information that must be included along with the images, the relevant measures of algorithm performance, and the number of required images. In this article we outline assessment methodologies and statistical issues as they relate to several potential uses of the LIDC database. We review methods for performance assessment and discuss issues of defining "truth" as well as the complications that arise when truth information is not available. We also discuss issues about sizing and populating a database.
Neubauer, Jakob; Benndorf, Matthias; Reidelbach, Carolin; Krauß, Tobias; Lampert, Florian; Zajonc, Horst; Kotter, Elmar; Langer, Mathias; Fiebich, Martin; Goerke, Sebastian M.
2016-01-01
Purpose To compare the diagnostic accuracy of radiography, to radiography equivalent dose multidetector computed tomography (RED-MDCT) and to radiography equivalent dose cone beam computed tomography (RED-CBCT) for wrist fractures. Methods As study subjects we obtained 10 cadaveric human hands from body donors. Distal radius, distal ulna and carpal bones (n = 100) were artificially fractured in random order in a controlled experimental setting. We performed radiation dose equivalent radiography (settings as in standard clinical care), RED-MDCT in a 320 row MDCT with single shot mode and RED-CBCT in a device dedicated to musculoskeletal imaging. Three raters independently evaluated the resulting images for fractures and the level of confidence for each finding. Gold standard was evaluated by consensus reading of a high-dose MDCT. Results Pooled sensitivity was higher in RED-MDCT with 0.89 and RED-MDCT with 0.81 compared to radiography with 0.54 (P = < .004). No significant differences were detected concerning the modalities’ specificities (with values between P = .98). Raters' confidence was higher in RED-MDCT and RED-CBCT compared to radiography (P < .001). Conclusion The diagnostic accuracy of RED-MDCT and RED-CBCT for wrist fractures proved to be similar and in some parts even higher compared to radiography. Readers are more confident in their reporting with the cross sectional modalities. Dose equivalent cross sectional computed tomography of the wrist could replace plain radiography for fracture diagnosis in the long run. PMID:27788215
Aggarwal, Shivani R; Clavel, Marie-Annick; Messika-Zeitoun, David; Cueff, Caroline; Malouf, Joseph; Araoz, Philip A; Mankad, Rekha; Michelena, Hector; Vahanian, Alec; Enriquez-Sarano, Maurice
2013-01-01
Aortic valve calcification (AVC) is the intrinsic mechanism of valvular obstruction leading to aortic stenosis (AS) and is measurable by multidetector computed tomography. The link between sex and AS is controversial and that with AVC is unknown. We prospectively performed multidetector computed tomography in 665 patients with AS (aortic valve area, 1.05±0.35 cm(2); mean gradient, 39±19 mm Hg) to measure AVC and to assess the impact of sex on the AVC-AS severity link in men and women. AS severity was comparable between women and men (peak aortic jet velocity: 4.05±0.99 versus 3.93±0.91 m/s, P=0.11; aortic valve area index: 0.55±0.20 versus 0.56±0.18 cm(2)/m(2); P=0.46). Conversely, AVC load was lower in women versus men (1703±1321 versus 2694±1628 arbitrary units; P<0.0001) even after adjustment for their smaller body surface area or aortic annular area (both P<0.0001). Thus, odds of high-AVC load were much greater in men than in women (odds ratio, 5.07; P<0.0001). Although AVC showed good associations with hemodynamic AS severity in men and women (all r>0.67; P<0.0001), for any level of AS severity measured by peak aortic jet velocity or aortic valve area index, AVC load, absolute or indexed, was higher in men versus women (all P≤0.01). In this large AS population, women incurred similar AS severity than men for lower AVC loads, even after indexing for their smaller body size. Hence, the relationship between valvular calcification process and AS severity differs in women and men, warranting further pathophysiological inquiry. For AS severity diagnostic purposes, interpretation of AVC load should be different in men and in women.
Khalique, Omar K; Hahn, Rebecca T; Gada, Hemal; Nazif, Tamim M; Vahl, Torsten P; George, Isaac; Kalesan, Bindu; Forster, Molly; Williams, Mathew B; Leon, Martin B; Einstein, Andrew J; Pulerwitz, Todd C; Pearson, Gregory D N; Kodali, Susheel K
2014-08-01
This study sought to determine the impact of quantity and location of aortic valve calcification (AVC) on paravalvular regurgitation (PVR) and rates of post-dilation (PD) immediately after transcatheter aortic valve replacement (TAVR). The impact of AVC in different locations within the aortic valve complex is incompletely understood. This study analyzed 150 patients with severe, symptomatic aortic stenosis who underwent TAVR. Total AVC volume scores were calculated from contrast-enhanced multidetector row computed tomography imaging. AVC was divided by leaflet sector and region (Leaflet, Annulus, left ventricular outflow tract [LVOT]), and a combination of LVOT and Annulus (AnnulusLVOT). Asymmetry was assessed. Receiver-operating characteristic analysis was performed with greater than or equal to mild PVR and PD as classification variables. Logistic regression was performed. Quantity of and asymmetry of AVC for all regions of the aortic valve complex predicted greater than or equal to mild PVR by receiver-operating characteristic analysis (area under the curve = 0.635 to 0.689), except Leaflet asymmetry. Receiver-operating characteristic analysis for PD was significant for quantity and asymmetry of AVC in all regions, with higher area under the curve values than for PVR (area under the curve = 0.648 to 0.741). On multivariable analysis, Leaflet and AnnulusLVOT calcification were independent predictors of both PVR and PD regardless of multidetector row computed tomography area cover index. Quantity and asymmetry of AVC in all regions of the aortic valve complex predict greater than or equal to mild PVR and performance of PD, with the exception of Leaflet asymmetry. Quantity of AnnulusLVOT and Leaflet calcification independently predict PVR and PD when taking into account multidetector row computed tomography area cover index. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Robert-Ebadi, H; Glauser, F; Planquette, B; Moumneh, T; Le Gal, G; Righini, M
2017-08-01
Essentials Safety of computed tomography (CTPA) to exclude pulmonary embolism (PE) in all patients is debated. We analysed the outcome of PE-likely outpatients left untreated after negative CTPA alone. The 3-month venous thromboembolic risk in these patients was very low (0.6%; 95% CI 0.2-2.3). Multidetector CTPA alone safely excludes PE in patients with likely clinical probability. Background In patients with suspected pulmonary embolism (PE) classified as having a likely or high pretest clinical probability, the need to perform additional testing after a negative multidetector computed tomography pulmonary angiography (CTPA) finding remains a matter of debate. Objectives To assess the safety of excluding PE by CTPA without additional imaging in patients with a likely pretest probability of PE. Patients/Methods We retrospectively analyzed patients included in two multicenter management outcome studies that assessed diagnostic algorithms for PE diagnosis. Results Two thousand five hundred and twenty-two outpatients with suspected PE were available for analysis. Of these 2522 patients, 845 had a likely clinical probability as assessed by use of the simplified revised Geneva score. Of all of these patients, 314 had the diagnosis of PE excluded by a negative CTPA finding alone without additional testing, and were left without anticoagulant treatment and followed up for 3 months. Two patients presented with a venous thromboembolism (VTE) during follow-up. Therefore, the 3-month VTE risk in likely-probability patients after a negative CTPA finding alone was 2/314 (0.6%; 95% confidence interval [CI] 0.2-2.3%). Conclusions In outpatients with suspected PE and a likely clinical probability as assessed by use of the simplified revised Geneva score, CTPA alone seems to be able to safely exclude PE, with a low 3-month VTE rate, which is similar to the VTE rate following the gold standard, i.e. pulmonary angiography. © 2017 International Society on Thrombosis and Haemostasis.
Inci, Ercan; Ekizoglu, Oguzhan; Turkay, Rustu; Aksoy, Sema; Can, Ismail Ozgur; Solmaz, Dilek; Sayin, Ibrahim
2016-10-01
Morphometric analysis of the mandibular ramus (MR) provides highly accurate data to discriminate sex. The objective of this study was to demonstrate the utility and accuracy of MR morphometric analysis for sex identification in a Turkish population.Four hundred fifteen Turkish patients (18-60 y; 201 male and 214 female) who had previously had multidetector computed tomography scans of the cranium were included in the study. Multidetector computed tomography images were obtained using three-dimensional reconstructions and a volume-rendering technique, and 8 linear and 3 angular values were measured. Univariate, bivariate, and multivariate discriminant analyses were performed, and the accuracy rates for determining sex were calculated.Mandibular ramus values produced high accuracy rates of 51% to 95.6%. Upper ramus vertical height had the highest rate at 95.6%, and bivariate analysis showed 89.7% to 98.6% accuracy rates with the highest ratios of mandibular flexure upper border and maximum ramus breadth. Stepwise discrimination analysis gave a 99% accuracy rate for all MR variables.Our study showed that the MR, in particular morphometric measures of the upper part of the ramus, can provide valuable data to determine sex in a Turkish population. The method combines both anthropological and radiologic studies.
USDA-ARS?s Scientific Manuscript database
Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...
Automated Quantification of Pneumothorax in CT
Do, Synho; Salvaggio, Kristen; Gupta, Supriya; Kalra, Mannudeep; Ali, Nabeel U.; Pien, Homer
2012-01-01
An automated, computer-aided diagnosis (CAD) algorithm for the quantification of pneumothoraces from Multidetector Computed Tomography (MDCT) images has been developed. Algorithm performance was evaluated through comparison to manual segmentation by expert radiologists. A combination of two-dimensional and three-dimensional processing techniques was incorporated to reduce required processing time by two-thirds (as compared to similar techniques). Volumetric measurements on relative pneumothorax size were obtained and the overall performance of the automated method shows an average error of just below 1%. PMID:23082091
Williams, Michelle C; Golay, Saroj K; Hunter, Amanda; Weir-McCall, Jonathan R; Mlynska, Lucja; Dweck, Marc R; Uren, Neal G; Reid, John H; Lewis, Steff C; Berry, Colin; van Beek, Edwin J R; Roditi, Giles; Newby, David E; Mirsadraee, Saeed
2015-01-01
Introduction Observer variability can influence the assessment of CT coronary angiography (CTCA) and the subsequent diagnosis of angina pectoris due to coronary heart disease. Methods We assessed 210 CTCAs from the Scottish COmputed Tomography of the HEART (SCOT-HEART) trial for intraobserver and interobserver variability. Calcium score, coronary angiography and image quality were evaluated. Coronary artery disease was defined as none (<10%), mild (10–49%), moderate (50–70%) and severe (>70%) luminal stenosis and classified as no (<10%), non-obstructive (10–70%) or obstructive (>70%) coronary artery disease. Post-CTCA diagnosis of angina pectoris due to coronary heart disease was classified as yes, probable, unlikely or no. Results Patients had a mean body mass index of 29 (28, 30) kg/m2, heart rate of 58 (57, 60)/min and 62% were men. Intraobserver and interobserver agreements for the presence or absence of coronary artery disease were excellent (95% agreement, κ 0.884 (0.817 to 0.951) and good (91%, 0.791 (0.703 to 0.879)). Intraobserver and interobserver agreement for the presence or absence of angina pectoris due to coronary heart disease were excellent (93%, 0.842 (0.918 to 0.755) and good (86%, 0.701 (0.799 to 0.603)), respectively. Observer variability of calcium score was excellent for calcium scores below 1000. More segments were categorised as uninterpretable with 64-multidetector compared to 320-multidetector CTCA (10.1% vs 2.6%, p<0.001) but there was no difference in observer variability. Conclusions Multicentre multidetector CTCA has excellent agreement in patients under investigation for suspected angina due to coronary heart disease. Trial registration number NCT01149590. PMID:26019881
Yi, Ji Sook; Han, Jong Kyu; Kim, Hyun-Joo
2015-01-01
Objective To assess inter-modality variability when evaluating cervical intervertebral disc herniation using 64-slice multidetector-row computed tomography (MDCT) and magnetic resonance imaging (MRI). Materials and Methods Three musculoskeletal radiologists independently reviewed cervical spine 1.5-T MRI and 64-slice MDCT data on C2-3 though C6-7 of 51 patients in the context of intervertebral disc herniation. Interobserver and inter-modality agreements were expressed as unweighted kappa values. Weighted kappa statistics were used to assess the extents of agreement in terms of the number of involved segments (NIS) in disc herniation and epicenter measurements collected using MDCT and MRI. Results The interobserver agreement rates upon evaluation of disc morphology by the three radiologists were in fair to moderate agreement (k = 0.39-0.53 for MDCT images; k = 0.45-0.56 for MRIs). When the disc morphology was categorized into two and four grades, the inter-modality agreement rates were moderate (k-value, 0.59) and substantial (k-value, 0.66), respectively. The inter-modality agreements for evaluations of the NIS (k-value, 0.78) and the epicenter (k-value, 0.79) were substantial. Also, the interobserver agreements for the NIS (CT; k-value, 0.85 and MRI; k-value, 0.88) and epicenter (CT; k-value, 0.74 and MRI; k-value, 0.70) evaluations by two readers were substantial. MDCT tended to underestimate the extent of herniated disc lesions compared with MRI. Conclusion Multidetector-row computed tomography and MRI showed a moderate-to-substantial degree of inter-modality agreement for the assessment of herniated cervical discs. MDCT images have a tendency to underestimate the anterior/posterior extent of the herniated disc compared with MRI. PMID:26175589
Posterior semicircular canal dehiscence: value of VEMP and multidetector CT.
Vanspauwen, R; Salembier, L; Van den Hauwe, L; Parizel, P; Wuyts, F L; Van de Heyning, P H
2006-01-01
To illustrate that posterior semicircular canal dehiscence can present similarly to superior semicircular canal dehiscence. The symptomatology initially presented as probable Menière's disease evolving into a mixed conductive hearing loss with a Carhart notch-type perceptive component suggestive of otosclerosis-type stapes fixation. A small hole stapedotomy resulted in a dead ear and a horizontal semicircular canal hypofunction. Recurrent incapacitating vertigo attacks developed. Vestibular evoked myogenic potential (VEMP) testing demonstrated intact vestibulocollic reflexes. Additional evaluation with high resolution multidetector computed tomography (MDCT) of the temporal bone showed a dehiscence of the left posterior semicircular canal. Besides superior semicircular canal dehiscence, posterior semicircular canal dehiscence has to be included in the differential diagnosis of atypical Menière's disease and/or low tone conductive hearing loss. The value of performing MDCT before otosclerosis-type surgery is stressed. VEMP might contribute to establishing the differential diagnosis.
de Freitas, Ricardo Miguel Costa; Andrade, Celi Santos; Caldas, José Guilherme Mendes Pereira; Kanas, Alexandre Fligelman; Cabral, Richard Halti; Tsunemi, Miriam Harumi; Rodríguez, Hernán Joel Cervantes; Rabbani, Said Rahnamaye
2015-05-01
New spinal interventions or implants have been tested on ex vivo or in vivo porcine spines, as they are readily available and have been accepted as a comparable model to human cadaver spines. Imaging-guided interventional procedures of the spine are mostly based on fluoroscopy or, still, on multidetector computed tomography (MDCT). Cone-beam computed tomography (CBCT) and magnetic resonance imaging (MRI) are also available methods to guide interventional procedures. Although some MDCT data from porcine spines are available in the literature, validation of the measurements on CBCT and MRI is lacking. To describe and compare the anatomical measurements accomplished with MDCT, CBCT, and MRI of lumbar porcine spines to determine if CBCT and MRI are also useful methods for experimental studies. An experimental descriptive-comparative study. Sixteen anatomical measurements of an individual vertebra from six lumbar porcine spines (n=36 vertebrae) were compared with their MDCT, CBCT, and MRI equivalents. Comparisons were made for the absolute values of the parameters. Similarities were found in all imaging methods. Significant correlation (p<.05) was observed with all variables except those that included cartilaginous tissue from the end plates when the anatomical study was compared with the imaging methods. The CBCT and MRI provided imaging measurements of the lumbar porcine spines that were similar to the anatomical and MDCT data, and they can be useful for specific experimental research studies. Copyright © 2015 Elsevier Inc. All rights reserved.
MDCT detection of anomalous origins of the left main coronary artery: report of 2 cases.
Matsumoto, Naoya; Sato, Yuichi; Kunimasa, Taeko; Yoda, Shunichi; Yokoyama, Shinichiro; Takayama, Tadateru; Komatsu, Sei; Achenbach, Stephan; Saito, Satoshi; Hirayama, Atsushi
2008-11-28
The left main coronary artery (LMCA) arising either from the right sinus of Valsalva, separately from the right coronary artery (RCA), or from the RCA as a single coronary artery is an extremely rare coronary artery anomaly. We report 2 cases of anomalous origins of the LMCA detected by multidetector-row computed tomography.
Lacalzada-Almeida, Juan; De la Rosa-Hernández, Alejandro; Izquierdo-Gómez, María Manuela; García-Niebla, Javier; Hernández-Betancor, Iván; Bonilla-Arjona, Juan Alfonso; Barragán-Acea, Antonio; Laynez-Cerdeña, Ignacio
2018-01-01
A 61-year-old male with a prosthetic St Jude aortic valve size 24 presented with heart failure symptoms and minimal-effort angina. Eleven months earlier, the patient had undergone cardiac surgery because of an aortic root dilatation and bicuspid aortic valve with severe regurgitation secondary to infectious endocarditis by Coxiela burnetii and coronary artery disease in the left circumflex coronary artery. Then, a prosthesis valve and a saphenous bypass graft to the left circumflex coronary artery were placed. The patient was admitted to the Cardiology Department of Hospital Universitario de Canarias, Tenerife, Spain and a transthoracic echocardiography was performed that showed severe paraprosthetic aortic regurgitation and an aortic pseudoaneurysm. The 64-slice multidetector computed tomography confirmed the pseudoaneurysm, originating from the right sinus of Valsalva, with a compression of the native right coronary artery and a normal saphenous bypass graft. On the basis of these findings, we performed surgical treatment with a favorable postoperative evolution. In our case, results from complementary cardiac imaging techniques were crucial for patient management. The multidetector computed tomography allowed for a confident diagnosis of an unusual mechanism of coronary ischemia.
Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki
2013-01-01
This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; P<0.0001). MDCT can be used to clearly visualize subprosthetic pannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.
Raza, Mushahid; Elkhodair, Samer; Zaheer, Asif; Yousaf, Sohail
2013-11-01
A true gold standard to rule out a significant cervical spine injury in subset of blunt trauma patients with altered sensorium is still to be agreed upon. The objective of this study is to determine whether in obtunded adult patients with blunt trauma, a clinically significant injury to the cervical spine be ruled out on the basis of a normal multidetector cervical spine computed tomography. Comprehensive database search was conducted to include all the prospective and retrospective studies on blunt trauma patients with altered sensorium undergoing cervical spine multidetector CT scan as core imaging modality to "clear" the cervical spine. The studies used two main gold standards, magnetic resonance imaging of the cervical spine and/or prolonged clinical follow-up. The data was extracted to report true positive, true negatives, false positives and false negatives. Meta-analysis of sensitivity, specificity, negative and positive predictive values was performed using Meta Analyst Beta 3.13 software. We also performed a retrospective investigation comparing a robust clinical follow-up and/or cervical spine MR findings in 53 obtunded blunt trauma patients, who previously had undergone a normal multidetector CT scan of the cervical spine reported by a radiologist. A total of 10 studies involving 1850 obtunded blunt trauma patients with initial cervical spine CT scan reported as normal were included in the final meta-analysis. The cumulative negative predictive value and specificity of cervical spine CT of the ten studies was 99.7% (99.4-99.9%, 95% confidence interval). The positive predictive value and sensitivity was 93.7% (84.0-97.7%, 95% confidence interval). In the retrospective review of our obtunded blunt trauma patients, none was later diagnosed to have significant cervical spine injury that required a change in clinical management. In a blunt trauma patient with altered sensorium, a normal cervical spine CT scan is conclusive to safely rule out a clinically significant cervical spine injury. The results of this meta-analysis strongly support the removal of cervical precautions in obtunded blunt trauma patient after normal cervical spine computed tomography. Any further imaging like magnetic resonance imaging of the cervical spine should be performed on case-to-case basis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Sconfienza, Luca Maria; Mauri, Giovanni; Muzzupappa, Claudia; Poloni, Alessandro; Bandirali, Michele; Esseridou, Anastassia; Tritella, Stefania; Secchi, Francesco; Di Leo, Giovanni; Sardanelli, Francesco
2015-01-01
AIM: To investigate the prevalence of relevant incidental findings (RIFs) detected during routine abdominal contrast-enhanced computed tomography (CeCT). METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal CeCT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs (if needing additional workup) was noted. RESULTS: One thousand forty abdominal CeCT were performed in 949 patients (528 males, mean age 66 ± 14 years). No significant difference was found between inpatients and outpatients age and sex distribution (P > 0.472). RIFs were found in 195/1040 (18.8%) CeCT [inpatients = 108/470 (23.0%); outpatients = 87/570 (15.2%); P = 0.002]. RIFs were found in 30/440 (6.8%) CeCT with a previous exam and in 165/600 (27.5%) without a previous exam (P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different (P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs. CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal CeCT. Risk of overdiagnosis should be taken into account. PMID:26516432
Maier, I L; Leyhe, J R; Tsogkas, I; Behme, D; Schregel, K; Knauth, M; Schnieder, M; Liman, J; Psychogios, M-N
2018-05-01
One-stop management of mechanical thrombectomy-eligible patients with large-vessel occlusion represents an innovative approach in acute stroke treatment. This approach reduces door-to-reperfusion times by omitting multidetector CT, using flat detector CT as pre-mechanical thrombectomy imaging. The purpose of this study was to compare the diagnostic performance of the latest-generation flat detector CT with multidetector CT. Prospectively derived data from patients with ischemic stroke with large-vessel occlusion and mechanical thrombectomy were analyzed in this monocentric study. All included patients underwent multidetector CT before referral to our comprehensive stroke center and flat detector CT in the angiography suite before mechanical thrombectomy. Diagnosis of early ischemic signs, quantified by the ASPECTS, was compared between modalities using cross tables, the Pearson correlation, and Bland-Altman plots. The predictive value of multidetector CT- and flat detector CT-derived ASPECTS for functional outcome was investigated using area under the receiver operating characteristic curve analysis. Of 25 patients, 24 (96%) had flat detector CT with sufficient diagnostic quality. Median multidetector CT and flat detector CT ASPECTSs were 7 (interquartile range, 5.5-9 and 4.25-8, respectively) with a mean period of 143.6 ± 49.5 minutes between both modalities. The overall sensitivity was 85.1% and specificity was 83.1% for flat detector CT ASPECTS compared with multidetector CT ASPECTS as the reference technique. Multidetector CT and flat detector CT ASPECTS were strongly correlated ( r = 0.849, P < .001) and moderately predicted functional outcome (area under the receiver operating characteristic curve, 0.738; P = .007 and .715; P = .069, respectively). Determination of ASPECTS on flat detector CT is feasible, showing no significant difference compared with multidetector CT ASPECTS and a similar predictive value for functional outcome. Our findings support the use of flat detector CT for emergency stroke imaging before mechanical thrombectomy to reduce door-to-groin time. © 2018 by American Journal of Neuroradiology.
Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.
Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P
2005-12-01
Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.
Hirose, Tomohiro; Nitta, Norihisa; Shiraishi, Junji; Nagatani, Yukihiro; Takahashi, Masashi; Murata, Kiyoshi
2008-12-01
The aim of this study was to evaluate the usefulness of computer-aided diagnosis (CAD) software for the detection of lung nodules on multidetector-row computed tomography (MDCT) in terms of improvement in radiologists' diagnostic accuracy in detecting lung nodules, using jackknife free-response receiver-operating characteristic (JAFROC) analysis. Twenty-one patients (6 without and 15 with lung nodules) were selected randomly from 120 consecutive thoracic computed tomographic examinations. The gold standard for the presence or absence of nodules in the observer study was determined by consensus of two radiologists. Six expert radiologists participated in a free-response receiver operating characteristic study for the detection of lung nodules on MDCT, in which cases were interpreted first without and then with the output of CAD software. Radiologists were asked to indicate the locations of lung nodule candidates on the monitor with their confidence ratings for the presence of lung nodules. The performance of the CAD software indicated that the sensitivity in detecting lung nodules was 71.4%, with 0.95 false-positive results per case. When radiologists used the CAD software, the average sensitivity improved from 39.5% to 81.0%, with an increase in the average number of false-positive results from 0.14 to 0.89 per case. The average figure-of-merit values for the six radiologists were 0.390 without and 0.845 with the output of the CAD software, and there was a statistically significant difference (P < .0001) using the JAFROC analysis. The CAD software for the detection of lung nodules on MDCT has the potential to assist radiologists by increasing their accuracy.
Lane, John I; Witte, Robert J; Driscoll, Colin L W; Shallop, Jon K; Beatty, Charles W; Primak, Andrew N
2007-08-01
To use the improved resolution available with 64-slice multidetector computed tomography (MDCT) in vivo to localize the cochlear implant electrode array within the basal turn. Sixty-four-slice MDCT examinations of the temporal bones were retrospectively reviewed in 17 patients. Twenty-three implants were evaluated. Tertiary referral facility. All patients with previous cochlear implantation evaluated at our center between January 2004 and March 2006 were offered a computed tomographic examination as part of the study. In addition, preoperative computed tomographic examinations in patients being evaluated for a second bilateral device were included. Sixty-four-slice MDCT examination of the temporal bones. Localization of the electrode array within the basal turn from multiplanar reconstructions of the cochlea. Twenty-three implants were imaged in 17 patients. We were able to localize the electrode array within the scala tympani within the basal turn in 10 implants. In 3 implants, the electrode array was localized to the scala vestibuli. Migration of the electrode array from scala tympani to scala vestibuli was observed in three implants. Of the 7 implants in which localization of the electrode array was indeterminate, all had disease entities that obscured the definition of the normal cochlear anatomy. Sixty-four-slice MDCT with multiplanar reconstructions of the postoperative cochlea after cochlear implantation allows for accurate localization of the electrode array within the basal turn where normal cochlear anatomy is not obscured by the underlying disease process. Correlating the position of the electrode in the basal turn with surgical technique and implant design could be helpful in improving outcomes.
Nagy, Eszter; Apfaltrer, Georg; Riccabona, Michael; Singer, Georg; Stücklschweiger, Georg; Guss, Helmuth; Sorantin, Erich
2017-01-01
Objectives To evaluate and compare surface doses of a cone beam computed tomography (CBCT) and a multidetector computed tomography (MDCT) device in pediatric ankle and wrist phantoms. Methods Thermoluminescent dosimeters (TLD) were used to measure and compare surface doses between CBCT and MDCT in a left ankle and a right wrist pediatric phantom. In both modalities adapted pediatric dose protocols were utilized to achieve realistic imaging conditions. All measurements were repeated three times to prove test-retest reliability. Additionally, objective and subjective image quality parameters were assessed. Results Average surface doses were 3.8 ±2.1 mGy for the ankle, and 2.2 ±1.3 mGy for the wrist in CBCT. The corresponding surface doses in optimized MDCT were 4.5 ±1.3 mGy for the ankle, and 3.4 ±0.7 mGy for the wrist. Overall, mean surface dose was significantly lower in CBCT (3.0 ±1.9 mGy vs. 3.9 ±1.2 mGy, p<0.001). Subjectively rated general image quality was not significantly different between the study protocols (p = 0.421), whereas objectively measured image quality parameters were in favor of CBCT (p<0.001). Conclusions Adapted extremity CBCT imaging protocols have the potential to fall below optimized pediatric ankle and wrist MDCT doses at comparable image qualities. These possible dose savings warrant further development and research in pediatric extremity CBCT applications. PMID:28570626
Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed
2018-03-01
This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.
CT angiography of the renal arteries and veins: normal anatomy and variants.
Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat
2011-03-01
Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.
Tsili, Athina C; Argyropoulou, Maria I
2015-01-01
Renal cell carcinoma (RCC) accounts for approximately 90%-95% of kidney tumors. With the widespread use of cross-sectional imaging modalities, more than half of RCCs are detected incidentally, often diagnosed at an early stage. This may allow the planning of more conservative treatment strategies. Computed tomography (CT) is considered the examination of choice for the detection and staging of RCC. Multidetector CT (MDCT) with the improvement of spatial resolution and the ability to obtain multiphase imaging, multiplanar and three-dimensional reconstructions in any desired plane brought about further improvement in the evaluation of RCC. Differentiation of RCC from benign renal tumors based on MDCT features is improved. Tumor enhancement characteristics on MDCT have been found closely to correlate with the histologic subtype of RCC, the nuclear grade and the cytogenetic characteristics of clear cell RCC. Important information, including tumor size, localization, and organ involvement, presence and extent of venous thrombus, possible invasion of adjacent organs or lymph nodes, and presence of distant metastases are provided by MDCT examination. The preoperative evaluation of patients with RCC was improved by depicting the presence or absence of renal pseudocapsule and by assessing the possible neoplastic infiltration of the perirenal fat tissue and/or renal sinus fat compartment. PMID:26120380
Zhu, Caisong; Liu, Wei; Yang, Jun; Yang, Jing; Shao, Kangwei; Yuan, Lixin; Chen, Hairong; Lu, Wei; Zhu, Ying
2016-07-01
The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice.
Wang, Qiushi; Juan, Yu-Hsiang; Li, Yong; Xie, Jia-Jun; Liu, Hui; Huang, Hongfei; Liu, Zaiyi; Zheng, Junhui; Saboo, Ujwala S.; Saboo, Sachin S.; Liang, Changhong
2015-01-01
Abstract This study aims to evaluate the multidetector computed tomography (CT) imaging features in differentiating exophytic renal angiomyolipoma (AML) from retroperitoneal liposarcoma. We retrospectively enrolled 42 patients with confirmed exophytic renal AML (31 patients) or retroperitoneal liposarcoma (11 patients) during 8 years period to assess: renal parenchymal defect at site of tumor contact, supply from branches of renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, hemorrhage, non–fat-containing intratumoral nodules with postcontrast enhancement, calcification, renal sinus enlargement, anterior displacement of kidneys, and other associated AML. Renal parenchymal defect, renal arterial blood supply, tumoral vessel through the renal parenchyma, dilated intratumoral vessels, intratumoral/perirenal hemorrhage, renal sinus enlargement, and associated AML were seen only or mainly in exophytic renal AML (all P value < 0.05); however, non–fat-attenuating enhancing intratumoral nodules, intratumoral calcification, and anterior displacement of the kidney were more common in liposarcoma (all P value < 0.05). AMLs reveal renal parenchymal defect at the site of tumor contact, supply from renal artery, tumoral vessel extending through the renal parenchyma, dilated intratumoral vessels, intratumoral and/or perirenal hemorrhage, renal sinus enlargement, and associated AML. Non–fat-attenuating enhancing intratumoral nodules, intratumoral calcifications, and anterior displacement of kidney were more commonly seen in liposarcoma. PMID:26376398
Kushnir, Vladimir M; Wani, Sachin B; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris M; Mullady, Daniel K; Jonnalagadda, Sreenivasa S; Early, Dayna S; Edmundowicz, Steven A; Azar, Riad R
2013-04-01
There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: (1) evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP), and multidetector computed tomography (MDCT) for pancreas divisum; and (2) assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent endoscopic retrograde pancreatography and cross-sectional imaging. The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than the sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) (P < 0.001 for each). On review by expert radiologists, the sensitivity of MDCT increased to 83.3% in cases where the pancreatic duct was visualized, with fair IOA (κ = 0.34). Expert review of MRCPs did not identify any additional cases of pancreas divisum; IOA was moderate (κ = 0.43). Endoscopic ultrasound is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum.
Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.
Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae
2010-03-01
Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.
Paulus, Elena M; Fabian, Timothy C; Savage, Stephanie A; Zarzaur, Ben L; Botta, Vandana; Dutton, Wesley; Croce, Martin A
2014-02-01
Aggressive screening to diagnose blunt cerebrovascular injury (BCVI) results in early treatment, leading to improved outcomes and reduced stroke rates. While computed tomographic angiography (CTA) has been widely adopted for BCVI screening, evidence of its diagnostic sensitivity is marginal. Previous work from our institution using 32-channel multidetector CTA in 684 patients demonstrated an inadequate sensitivity of 51% (Ann Surg. 2011,253: 444-450). Digital subtraction angiography (DSA) continues to be the reference standard of diagnosis but has significant drawbacks of invasiveness and resource demands. There have been continued advances in CT technology, and this is the first report of an extensive experience with 64-channel multidetector CTA. Patients screened for BCVI using CTA and DSA (reference) at a Level 1 trauma center during the 12-month period ending in May 2012 were identified. Results of CTA and DSA, complications, and strokes were retrospectively reviewed and compared. A total of 594 patients met criteria for BCVI screening and underwent both CTA and DSA. One hundred twenty-eight patients (22% of those screened) had 163 injured vessels: 99 (61%) carotid artery injuries and 64 (39%) vertebral artery injuries. Sixty-four-channel CTA demonstrated an overall sensitivity per vessel of 68% and specificity of 92%. The 52 false-negative findings on CTA were composed of 34 carotid artery injuries and 18 vertebral artery injuries; 32 (62%) were Grade I injuries. Overall, positive predictive value was 36.2%, and negative predictive value was 97.5%. Six procedure-related complications (1%) occurred with DSA, including two iatrogenic dissections and one stroke. Sixty-four-channel CTA demonstrated a significantly improved sensitivity of 68% versus the 51% previously reported for the 32-channel CTA (p = 0.0075). Sixty-two percent of the false-negative findings occurred with low-grade injuries. Considering complications, cost, and resource demand associated with DSA, this study suggests that 64-channel CTA may replace DSA as the primary screening tool for BCVI. Diagnostic study, level III.
Dong, Zhi-Hui; Yang, Zhi-Gang; Chen, Tian-Wu; Chu, Zhi-Gang; Deng, Wen; Shao, Heng
2011-01-01
Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR=1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR=1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR= 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR= 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR=1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries.
Dong, Zhi-hui; Yang, Zhi-gang; Chen, Tian-wu; Chu, Zhi-gang; Deng, Wen; Shao, Heng
2011-01-01
PURPOSE: Massive earthquakes are harmful to humankind. This study of a historical cohort aimed to investigate the difference between earthquake-related crush thoracic traumas and thoracic traumas unrelated to earthquakes using a multi-detector Computed Tomography (CT). METHODS: We retrospectively compared an earthquake-exposed cohort of 215 thoracic trauma crush victims of the Sichuan earthquake to a cohort of 215 non-earthquake-related thoracic trauma patients, focusing on the lesions and coexisting injuries to the thoracic cage and the pulmonary parenchyma and pleura using a multi-detector CT. RESULTS: The incidence of rib fracture was elevated in the earthquake-exposed cohort (143 vs. 66 patients in the non-earthquake-exposed cohort, Risk Ratio (RR) = 2.2; p<0.001). Among these patients, those with more than 3 fractured ribs (106/143 vs. 41/66 patients, RR = 1.2; p<0.05) or flail chest (45/143 vs. 11/66 patients, RR = 1.9; p<0.05) were more frequently seen in the earthquake cohort. Earthquake-related crush injuries more frequently resulted in bilateral rib fractures (66/143 vs. 18/66 patients, RR = 1.7; p<0.01). Additionally, the incidence of non-rib fracture was higher in the earthquake cohort (85 vs. 60 patients, RR = 1.4; p<0.01). Pulmonary parenchymal and pleural injuries were more frequently seen in earthquake-related crush injuries (117 vs. 80 patients, RR = 1.5 for parenchymal and 146 vs. 74 patients, RR = 2.0 for pleural injuries; p<0.001). Non-rib fractures, pulmonary parenchymal and pleural injuries had significant positive correlation with rib fractures in these two cohorts. CONCLUSIONS: Thoracic crush traumas resulting from the earthquake were life threatening with a high incidence of bony thoracic fractures. The ribs were frequently involved in bilateral and severe types of fractures, which were accompanied by non-rib fractures, pulmonary parenchymal and pleural injuries. PMID:21789386
Atar, Eli; Kornowski, Ran; Fuchs, Shmuell; Naftali, Noa; Belenky, Alexander; Bachar, Gil N
2007-10-01
Myocardial bridging is a congenital condition in which a segment of an epicardial artery has an intramural course within the myocardium. The aim of the present study was to evaluate the prevalence of myocardial bridging and the ability of 64-slice coronary computed tomography angiography to identify myocardial bridging in asymptomatic adults. One hundred sixty-nine consecutive asymptomatic subjects underwent 64-row multidetector computed tomography (MDCT) of the coronary arteries. Two experienced CT radiologists identified myocardial bridging >1 mm in thickness, by consensus. We examined the frequency of myocardial bridging and evaluated the length, thickness, and coronary wall lesions. Myocardial bridges were found in 28 (17%) of 165 subjects. Twenty-one subjects (75%) had 1 bridge and 7 subjects (25%) had 2, for a total of 35 myocardial bridges. Twenty-one bridges (60%) were located in the left anterior descending, 8.5% in the diagonal branch, and 2.8% in the circumflex arteries. The segment beneath the myocardial bridge was always free of coronary wall plaques, but the arterial segment proximal to it had significant coronary wall plaques in 24 cases (68.6%). We found that the incidence of myocardial bridging in asymptomatic adults is 7%, which is in agreement with some pathologic studies in the literature. Our study shows that MDCT of the coronary arteries is a reliable and noninvasive technique, which can accurately locate the site of myocardial bridging, and measure its thickness, course, and length.
Annoni, Andrea Daniele; Mancini, Maria E; Andreini, Daniele; Formenti, Alberto; Mushtaq, Saima; Nobili, Enrica; Guglielmo, Marco; Baggiano, Andrea; Conte, Edoardo; Pepi, Mauro
2017-10-01
Multidetector Computed Tomography Angiography (MDCTA) is presently the imaging modality of choice for aortic disease. However, the effective radiation dose and the risk related to the use of contrast agents associated with MDCTA is an issue of concern. Aim of this study was to assess image quality of a low dose ECG-gated MDCTA of thoracic aorta using different concentration contrast media without tailored injection protocol. Two-hundred patients were randomised into four different scan protocols: Group A (Iodixanol 320 and 80 Kvp tube voltage), Group B (Iodixanol 320 and 100 Kvp tube voltage), Group C (Iomeprol 400 and 80 Kvp tube voltage) and Group D (Iomeprol 400 and 100 Kvp tube voltage). Image quality, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and effective dose (ED) were compared among groups. No significant differences in image noise, SNR and CNR between groups with the same tube voltage. Significant differences in SNR and CNR were found among groups with 80 kV versus groups using 100 kV but without differences in terms of image quality. ED was significantly lower in groups with 80 kV. Multidetector Computed Tomography Angiography protocols using 80 kV and low concentration contrast media are feasible without need of tailored injection protocols. © 2017 The Royal Australian and New Zealand College of Radiologists.
Epicardial adipose tissue as a predictor of coronary artery disease in asymptomatic subjects.
Bachar, Gil N; Dicker, Dror; Kornowski, Ran; Atar, Eli
2012-08-15
This study sought to elucidate the relation between epicardial adipose tissue (EAT) thickness measured by multidetector computed tomography and presence of coronary artery atherosclerosis. Recent studies have suggested that fat disposition in visceral organs and epicardial tissue could serve as a predictor of coronary artery disease (CAD). The sample included 190 asymptomatic subjects with ≥ 1 cardiovascular risk factor who were referred for cardiac computed tomographic angiography. Body mass index, blood pressure, fasting glucose level, and lipid profile were measured. Multidetector computed tomographic results were analyzed for atherosclerosis burden, calcium Agatston score, and EAT thickness: mean EAT values were 3.54 ± 1.59 mm in patients with atherosclerosis and 1.85 ± 1.28 mm in patients without atherosclerosis (p <0.001). On receiver operating characteristic analysis, an EAT value ≥ 2.4 mm predicted the presence of significant (>50% diameter) coronary artery stenosis. There was a significant difference in EAT values between patients with and without metabolic syndrome (2.58 ± 1.63 vs 2.04 ± 1.46 mm, p <0.05) and between patients with a calcium score >400 and <400 (3.38 ± 1.58 vs 2.02 ± 1.42 mm, p <0.0001). In conclusion, asymptomatic patients with CAD have significantly more EAT than patients without CAD. An EAT thickness of 2.4 mm is the optimal cutoff for prediction of presence of significant CAD. Copyright © 2012 Elsevier Inc. All rights reserved.
Jones, Jeryl C; Appt, Susan E; Bourland, J Daniel; Hoyer, Patricia B; Clarkson, Thomas B; Kaplan, Jay R
2007-09-01
Macaques are important models for menopause and associated diseases in women. A sensitive, noninvasive technique for quantifying changes in ovarian morphology would facilitate longitudinal studies focused on the health-related sequelae of naturally occurring or experimentally induced alterations in ovarian structure and function. Multidetector computed tomography (MDCT) is a fast, non-invasive imaging technique that uses X-rays, multiple rows of detectors, and computers to generate detailed slice images of structures. The purpose of this study was to describe the utility of MDCT for reliably characterizing ovarian morphology in macaques. Five macaques were scanned using contrast-enhanced MDCT. The following characteristics were described: 1) appearance of ovaries and adjacent landmarks, 2) effects of varying technical protocols on ovarian image quality, 3) radiation doses delivered to the pelvic region during scanning, and 4) MDCT estimates of ovarian volume and antral follicle counts versus those measured directly in ovarian tissue. Ovaries were distinguishable in all MDCT scans and exhibited heterogeneous contrast enhancement. Antral follicles appeared as focal areas of nonenhancement. Ovarian image quality with 5 pediatric scanning protocols was sufficient for discriminating ovarian margins. Pelvic region radiation doses ranged from 0.5 to 0.7 rad. Antral follicles counted using MDCT ranged from 3 to 5 compared with 3 to 4 counted using histology. Ovarian volumes measured using MDCT ranged from 0.41 to 0.67 ml compared with 0.40 to 0.65 ml by water displacement. MDCT is a promising technique for measuring longitudinal changes in macaque ovarian morphology reliably and noninvasively.
Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico
2017-04-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.
Sørgaard, Mathias; Linde, Jesper J; Hove, Jens D; Petersen, Jan R; Jørgensen, Tem B S; Abdulla, Jawdat; Heitmann, Merete; Kragelund, Charlotte; Hansen, Thomas Fritz; Udholm, Patricia M; Pihl, Christian; Kühl, J Tobias; Engstrøm, Thomas; Jensen, Jan Skov; Høfsten, Dan E; Kelbæk, Henning; Kofoed, Klaus F
2016-09-01
Patients admitted with chest pain are a diagnostic challenge because the majority does not have coronary artery disease (CAD). Assessment of CAD with coronary computed tomography angiography (CCTA) is safe, cost-effective, and accurate, albeit with a modest specificity. Stress myocardial computed tomography perfusion (CTP) has been shown to increase the specificity when added to CCTA, without lowering the sensitivity. This article describes the design of a randomized controlled trial, CATCH-2, comparing a clinical diagnostic management strategy of CCTA alone against CCTA in combination with CTP. Patients with acute-onset chest pain older than 50 years and with at least one cardiovascular risk factor for CAD are being prospectively enrolled to this study from 6 different clinical sites since October 2013. A total of 600 patients will be included. Patients are randomized 1:1 to clinical management based on CCTA or on CCTA in combination with CTP, determining the need for further testing with invasive coronary angiography including measurement of the fractional flow reserve in vessels with coronary artery lesions. Patients are scanned with a 320-row multidetector computed tomography scanner. Decisions to revascularize the patients are taken by the invasive cardiologist independently of the study allocation. The primary end point is the frequency of revascularization. Secondary end points of clinical outcome are also recorded. The CATCH-2 will determine whether CCTA in combination with CTP is diagnostically superior to CCTA alone in the management of patients with acute-onset chest pain. Copyright © 2015 Elsevier Inc. All rights reserved.
Shokri, Abbas; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed
2018-01-01
Purpose This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. Results In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes (P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results. PMID:29581947
Imaging of Combat-Related Thoracic Trauma - Review of Penetrating Trauma.
Lichtenberger, John P; Kim, Andrew M; Fisher, Dane; Tatum, Peter S; Neubauer, Brian; Peterson, P Gabriel; Carter, Brett W
2018-03-01
Combat-related thoracic trauma is a significant contributor to morbidity and mortality of the casualties from Operation Enduring Freedom (OEF) and Operation Iraqi Freedom (OIF). Penetrating, blunt, and blast injuries were the most common mechanisms of trauma. Imaging plays a key role in the management of combat-related thoracic trauma casualties. This review discusses the imaging manifestations of thoracic injuries from penetrating trauma, emphasizing epidemiology and diagnostic clues seen during OEF and OIF. The assessment of radiologic findings in patients who suffer from combat-related thoracic trauma is the basis of this review article. The imaging modalities for this study include multi-detector computed tomography and chest radiography. High-velocity penetrating projectile injuries appear as hemorrhage and re-expansion pulmonary edema from the temporary cavity and a linear, blood-filled track from the permanent cavity. In cases where the projectile passes totally through the body, entrance wounds at the skin surface and tracks through the subcutaneous tissues may be the only indications of penetrating trauma. When assessing vascular injury, special attention should be paid to the right hilum in contrast-enhanced multi-detector computed tomography, as contrast is concentrated in the superior vena cava and superior cavoatrial junction may obscure small fragments. Additionally, CT angiography may show vessel disruption or extravasation of contrast distal to normal vessel location in addition to intraluminal filling defects and pseudo-aneurysms. Tension pneumopericardium may rarely complicate penetrating or blunt chest trauma. On imaging, distension of the pericardial sack by pneumopericardium and compression of the heart support the diagnosis of tension. On multi-detector computed tomography in the acute trauma setting, fluid in the pleural space should be considered hemothorax, particularly when Hounsfield units are above 35. Acutely, extravasated blood will have similar attenuation to the thoracic vasculature, whereas clotted blood will have higher values of 50-90 Hounsfield units. Combat-related thoracic trauma continues to be a significant contributor to the morbidity and mortality of those injured during OEF and OIF. This review of the imaging manifestations of penetrating thoracic injury during OEF and OIF focuses on key diagnostic findings for clinicians caring for combat casualties. The distinct injury pattern and atypical imaging manifestations of penetrating trauma are important to recognize early due to the acuity of this patient population and the influence of accurate diagnosis on clinical management.
Kumar, Sheo; Neyaz, Zafar; Gupta, Archna
2010-01-01
The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.
Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna
2014-01-01
Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.
Boulif, Jamila; Gerber, Bernhard; Slimani, Alisson; Lazam, Siham; de Meester, Christophe; Piérard, Sophie; Pasquet, Agnès; Pouleur, Anne-Catherine; Vancraeynest, David; El Khoury, Gébrine; de Kerchove, Laurent; Noirhomme, Philippe; Vanoverschelde, Jean-Louis
To validate aortic valve calcium (AVC) load measurements by multidetector row computed tomography (MDCT), to evaluate the impact of tube potential and slice thickness on AVC scores, to examine the accuracy of AVC load in distinguishing severe from nonsevere aortic stenosis (AS) and to investigate its effectiveness as an alternative diagnosis method when echocardiography remains inconclusive. We prospectively studied 266 consecutive patients with moderate to severe AS who underwent MDCT to measure AVC load and a comprehensive echocardiographic examination to assess AS severity. AVC load was validated against valve weight in 57 patients undergoing aortic valve replacement. The dependence of AVC scores on tube potential and slice thickness was also tested, as well as the relationship between AVC load and echocardiographic criteria of AS severity. MDCT Agatston score correlated well with valve weight (r = 0.82, p < 0.001) and hemodynamic indices of AS severity (all p < 0.001). Ex-vivo Agatston scores decreased significantly with increasing tube potential and slice thickness (repeated measures ANOVA p < 0.001). Multivariate analysis identified mean gradient, the indexed effective orifice area, male gender and left ventricular outflow tract cross-sectional area as independent correlates of the in-vivo AVC load. MDCT-derived AVC load correlated well with valve weight and hemodynamic indices of AS severity. It also depends on tube potential and slice thickness, thus suggesting that these parameters should be standardized to optimize reproducibility and accuracy. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Aladmawi, Mohamed A.; Vriz, Olga; Galzerano, Domenico
2017-01-01
Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus. PMID:28540078
Hilar cholangiocarcinoma: Cross sectional evaluation of disease spectrum
Mahajan, Mangal S; Moorthy, Srikanth; Karumathil, Sreekumar P; Rajeshkannan, R; Pothera, Ramchandran
2015-01-01
Although hilar cholangiocarcinoma is relatively rare, it can be diagnosed on imaging by identifying its typical pattern. In most cases, the tumor appears to be centered on the right or left hepatic duct with involvement of the ipsilateral portal vein, atrophy of hepatic lobe on that side, and invasion of adjacent liver parenchyma. Multi-detector computed tomography (MDCT) and magnetic resonance cholangiopancreatography (MRCP) are commonly used imaging modalities to assess the longitudinal and horizontal spread of tumor. PMID:25969643
Hirono, Keiichi; Hata, Yukiko; Miyao, Naruaki; Nakaoka, Hideyuki; Saito, Kazuyoshi; Ibuki, Keijiro; Watanabe, Kazuhiro; Ozawa, Sayaka; Higuma, Tomonori; Yoshimura, Naoki; Nishida, Naoki; Ichida, Fukiko
2016-09-01
Anomalous origin of the right coronary artery (AORCA) is a rare congenital anomaly that may cause myocardial ischemia and sudden death. We reviewed the clinicopathological records of three cases of AORCA, and compared these with two cases of sudden cardiac death with AORCA revealed by autopsy. We report three juvenile cases with an AORCA originating above the commissural junction between the left and right aortic sinuses, with interarterial and intramural compression. They presented with exertional symptoms and were diagnosed with an AORCA by multidetector computed tomography (MDCT), which successfully delineated the spatial resolution of the anomalous origin and course of the right coronary artery (RCA), in the operating room. All three underwent successful surgical unroofing of the RCA. Two cases of sudden cardiac death with AORCA revealed by autopsy showed a slit-like orifice, acute-angled take-off, and long intramural course of the RCA, resembling the RCAs of three juvenile cases. It is crucial to be alert to the presentation of exertional symptoms, as sudden death may be the first manifestation of an anomalous coronary artery, such as those observed in these three cases. MDCT provided an excellent definition and spatial resolution of the unusual origin and intramural course of the RCA, facilitating the correct surgical remedy and resulting in a good outcome for the patients. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Role of multidetector computed tomography in evaluating incidentally detected breast lesions.
Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile
2015-01-01
Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.
Rocco, Francesco; Cozzi, Luigi Alberto; Cozzi, Gabriele
2015-07-01
To use triphasic multi-detector computed tomography (MDCT) to study the renal segmental arterial anatomy and its relationship with the urinary tract to plan nephron-sparing surgery (NSS). One hundred and fifty nine patients underwent abdominal contrast-enhanced MDCT. We evaluated renal arteries and parenchymal vasculature. In 61 patients, the arteries and the urinary tract were represented simultaneously. 86.60% presented a single renal artery; 13.4%, multiple arteries. All single renal arteries divided into anterior and posterior branch before the hilum. The anterior artery branched into a superior, middle, and inferior branch. In 43.14%, the inferior artery arose before the others; in 45.75%, the superior artery arose before the others; in 9.80%, the branches shared a common trunk. In 26.80%, the posterior artery supplies the entire posterior surface; in 73.20%, it ends along the inferior calyx. In 96.73%, the upper pole was vascularized by the anterior superior branch and the posterior artery: the "tuning fork". MDCT showed four vascular segments in 96.73% and five in 3.27%. MDCT showed two avascular areas: the first along the projection of the inferior calyx on the posterior aspect, the second between the branches of the "tuning fork". The arterial phase provides the arterial tree representation; the delayed phase shows arteries and urinary tract simultaneously. MDCT provides a useful representation of the renal anatomy prior to intervascular-intrarenal NSS.
ZHU, CAISONG; LIU, WEI; YANG, JUN; YANG, JING; SHAO, KANGWEI; YUAN, LIXIN; CHEN, HAIRONG; LU, WEI; ZHU, YING
2016-01-01
The aim of the present study was to compare the multidetector computed tomography (MDCT) features of benign and malignant nodules in patients with chronic lymphocytic thyroiditis (CLT). MDCT findings, including the size, solid percentage, calcification, margin, capsule, anteroposterior-transverse diameter ratio as well as the mode and the degree of enhancement of 137 thyroid nodules in 127 CLT cases were retrospectively analyzed. Furthermore, the correlation between MDCT findings and pathological results combined with the CT perfusion imaging was analyzed for the differences between benign and malignant nodules. A total of 77.5% (31/40) of malignant nodules were completely solid, and 33% (32/97) of benign nodules were predominantly cystic. Compared with the benign nodules, micro-calcification and internal calcification were more frequently observed in the malignant nodules (P<0.05). MDCT features such as ill-defined margin, absence of capsule or incomplete capsule or homogeneous enhancement were more likely to be present in the malignant nodules (P<0.05). Nevertheless, no significant difference was observed in the enhancement degree at arterial or venous phase between benign and malignant nodules (P>0.05). MDCT features are useful in differentiating the benign and malignant nodules in CLT patients, and it may be essential for a radiologist to review the MDCT characteristics of nodules in the clinical practice. PMID:27347131
Ozcan, H Nursun; Gormez, Ayşegul; Ozsurekci, Yasemin; Karakaya, Jale; Oguz, Berna; Unal, Sule; Cetin, Mualla; Ceyhan, Mehmet; Haliloglu, Mithat
2017-02-01
Computed tomography (CT) is commonly used to detect pulmonary infection in immunocompromised children. To compare MRI and multidetector CT findings of pulmonary abnormalities in immunocompromised children. Seventeen neutropaenic children (6 girls; ages 2-18 years) were included. Non-contrast-enhanced CT was performed with a 64-detector CT scanner. Axial and coronal non-enhanced thoracic MRI was performed using a 1.5-T scanner within 24 h of the CT examination (true fast imaging with steady-state free precession, fat-saturated T2-weighted turbo spin echo with motion correction, T2-weighted half-Fourier single-shot turbo spin echo [HASTE], fat-saturated T1-weighted spoiled gradient echo). Pulmonary abnormalities (nodules, consolidations, ground glass opacities, atelectasis, pleural effusion and lymph nodes) were evaluated and compared among MRI sequences and between MRI and CT. The relationship between MRI sequences and nodule sizes was examined by chi- square test. Of 256 CT lesions, 207 (81%, 95% confidence interval [CI] 76-85%) were detected at MRI. Of 202 CT-detected nodules, 157 (78%, 95% CI 71-83%) were seen at motion-corrected MRI. Of the 1-5-mm nodules, 69% were detected by motion-corrected T2-weighted MRI and 38% by HASTE MRI. Sensitivity of MRI (both axial fat-saturated T2-weighted turbo spin echo with variable phase encoding directions (BLADE) images and HASTE sequences) to detect pulmonary abnormalities is promising.
Kushnir, Vladimir M.; Wani, Sachin B.; Fowler, Kathryn; Menias, Christine; Varma, Rakesh; Narra, Vamsi; Hovis, Christine; Murad, Faris; Mullady, Daniel; Jonnalagadda, Sreenivasa S.; Early, Dayna S.; Edmundowicz, Steven A.; Azar, Riad R.
2014-01-01
OBJECTIVES There are limited data comparing imaging modalities in the diagnosis of pancreas divisum. We aimed to: 1. Evaluate the sensitivity of endoscopic ultrasound (EUS), magnetic resonance cholangiopancreatography (MRCP) and multi-detector computed tomography (MDCT) for pancreas divisum. 2. Assess interobserver agreement (IOA) among expert radiologists for detecting pancreas divisum on MDCT and MRCP. METHODS For this retrospective cohort study, we identified 45 consecutive patients with pancreaticobiliary symptoms and pancreas divisum established by endoscopic retrograde pancreatography (ERP) who underwent EUS and cross-sectional imaging. The control group was composed of patients without pancreas divisum who underwent ERP and cross-sectional imaging. RESULTS The sensitivity of EUS for pancreas divisum was 86.7%, significantly higher than sensitivity reported in the medical records for MDCT (15.5%) or MRCP (60%) [p<0.001 for each]. On review by expert radiologists the sensitivity of MDCT increased to 83.3% in cases where the pancreatic duct was visualized, with fair IOA (қ=0.34). Expert review of MRCPs did not identify any additional cases of pancreas divisum; IOA was moderate (қ=0.43). CONCLUSIONS EUS is a sensitive test for diagnosing pancreas divisum and is superior to MDCT and MRCP. Review of MDCT studies by expert radiologists substantially raises its sensitivity for pancreas divisum. PMID:23211370
Foster, Allison; Morandi, Federica; May, Elizabeth
2015-01-01
Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. © 2014 American College of Veterinary Radiology.
Torimitsu, Suguru; Makino, Yohsuke; Saitoh, Hisako; Sakuma, Ayaka; Ishii, Namiko; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Yamaguchi, Rutsuko; Hashimoto, Mari; Hoshioka, Yumi; Iwase, Hirotaro
2015-12-01
Sex estimation of decomposed or skeletal remains is clearly important in forensic contexts. Recently, contemporary population-specific data has been obtained using multidetector computed tomography (MDCT) scanning. The main purpose of this study was to investigate skeletal pelvic dimorphism in a contemporary Japanese forensic sample and to quantify the accuracy of sex estimation using various pelvic measurements obtained from three-dimensional (3D) CT images. This study used a total of 208 cadavers (104 males, 104 females) of which postmortem CT scanning and subsequent forensic autopsy were conducted between December 2011 and August 2014. Eleven measurements of each pelvis were obtained from 3D CT reconstructed images that extracted only bone data. The measurements were analyzed using descriptive statistics and discriminant function analyses. All except one measurement were dimorphic in terms of sex differences. Univariate discriminant function analyses using these measurements provided sex classification accuracy rates of 62.0-98.1%. The subpubic angle was found to contribute most significantly to accurate sex estimation. Multivariate discriminant functions yielded sex prediction accuracy rates of 63.9-98.1%. In conclusion, the pelvic measurements obtained from 3D CT images of a contemporary Japanese population successfully demonstrated sexual dimorphism and may be useful for the estimation of skeletal sex in the field of forensic anthropology. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Jinzaki, Masahiro; Okabe, Teruo; Endo, Ayaka; Kawamura, Akio; Koga, Seiko; Yamada, Minoru; Fukuda, Keiichi; Kuribayashi, Sachio
2012-01-01
To clarify multidetector computed tomography (MDCT) findings of attenuated plaque detected by intravascular ultrasound (IVUS). One hundred and fifty-four patients with stable angina underwent MDCT before IVUS. The attenuated plaque was identified in the targeted artery with IVUS, and the same artery was analyzed with MDCT for the presence of a high density area (HDA) >130 Hounsfield units (HU), and a low density area (LDA) <30 HU. A HDA in attenuated plaque was compared with that in calcified plaque. Ten attenuated plaques and 15 calcified plaques were identified in 9 of 154 patients (males=9, 66.2 ± 9.5 years). Eight of the 10 attenuated plaques and all 15 calcified plaques were accompanied with a HDA on MDCT. The HDA ranged from 174 to 667 HU (mean 389.0 ± 148.3 HU) in the 8 attenuated plaques, and from 545 to 1,205 HU (mean 920.9 ± 215.9 HU) in 15 calcified plaques. There was a significant difference in CT density of the HDA between the attenuated and calcified plaque (P<0.001). All attenuated plaques contained LDA <30 HU in the portions without HDA. MDCT has the ability to demonstrate attenuated plaque as the combination of HDA (approximately 400 HU on average) and LDA <30 HU. The HDA can be differentiated from calcified plaque by its lower CT density value.
Hirose, Tomoaki; Igami, Tsuyoshi; Koga, Kusuto; Hayashi, Yuichiro; Ebata, Tomoki; Yokoyama, Yukihiro; Sugawara, Gen; Mizuno, Takashi; Yamaguchi, Junpei; Mori, Kensaku; Nagino, Masato
2017-03-01
Fusion angiography using reconstructed multidetector-row computed tomography (MDCT) images, and cholangiography using reconstructed images from MDCT with a cholangiographic agent include an anatomical gap due to the different periods of MDCT scanning. To conquer such gaps, we attempted to develop a cholangiography procedure that automatically reconstructs a cholangiogram from portal-phase MDCT images. The automatically produced cholangiography procedure utilized an original software program that was developed by the Graduate School of Information Science, Nagoya University. This program structured 5 candidate biliary tracts, and automatically selected one as the candidate for cholangiography. The clinical value of the automatically produced cholangiography procedure was estimated based on a comparison with manually produced cholangiography. Automatically produced cholangiograms were reconstructed for 20 patients who underwent MDCT scanning before biliary drainage for distal biliary obstruction. The procedure showed the ability to extract the 5 main biliary branches and the 21 subsegmental biliary branches in 55 and 25 % of the cases, respectively. The extent of aberrant connections and aberrant extractions outside the biliary tract was acceptable. Among all of the cholangiograms, 5 were clinically applied with no correction, 8 were applied with modest improvements, and 3 produced a correct cholangiography before automatic selection. Although our procedure requires further improvement based on the analysis of additional patient data, it may represent an alternative to direct cholangiography in the future.
Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook
2009-01-01
To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.
Penetrating Colorectal Injuries: Diagnostic Performance of Multidetector CT with Trajectography.
Dreizin, David; Boscak, Alexis R; Anstadt, Michael J; Tirada, Nikki; Chiu, William C; Munera, Felipe; Bodanapally, Uttam K; Hornick, Michael; Stein, Deborah M
2016-12-01
Purpose To determine the diagnostic performance of multidetector computed tomography (CT) with trajectography for penetrating colorectal injuries. Materials and Methods This institutional review board-approved and HIPAA-compliant study was a 6-year blinded retrospective review by two independent readers of 182 consecutive patients who preoperatively underwent 40- or 64-row multidetector CT for penetrating torso trauma below the diaphragm and had surgically confirmed findings. Colorectal perforation was present in 42 patients. Trajectory analysis with postprocessing software was used for all studies. Additional signs evaluated were rectal contrast agent leak, collections of extruded fecal material, mural defect, wall thickening, abnormal enhancement, free fluid or stranding, and free air. The quality of the colorectal contrast agent administration was recorded. Sensitivity, specificity, predictive values, areas under the receiver operating characteristic curves (AUCs), and Cohen κ were determined. Results In patients with rectal contrast agent administration (n = 151), AUCs were 0.90-0.91, which indicated excellent accuracy. Trajectory was sensitive (88%-91%). For single wounds (n = 104), sensitivity of trajectory was 96% for both readers, but was only 80% for multiple wounds (n = 47). Contrast agent leak was highly specific (96%-98%), but insensitive (42%-46%). Improved diagnostic performance was observed in patients with poor colonic distension or opacification. Accuracy remained high (AUC, 0.86-0.99) in the group without rectal contrast agent administration (n = 31). Conclusion Trajectory had excellent sensitivity, while rectal contrast agent leak was specific but insensitive. Sensitivity of trajectory was lower for multiple wounds. Accuracy remained high in patients without rectal contrast agent administration. © RSNA, 2016.
Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy
2003-10-01
To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P <.001). The effective radiation dose, calculated with a Monte Carlo simulation, was 1.4-10.0 mSv. Detection of small polyps (<5 mm) with multi-detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003
An evaluation of the use of oral contrast media in abdominopelvic CT.
Buttigieg, Erica Lauren; Grima, Karen Borg; Cortis, Kelvin; Soler, Sandro Galea; Zarb, Francis
2014-11-01
To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. • Positive oral contrast media are routinely used for abdominopelvic multidetector computed tomography • Experimental study comparing image quality using three different oral contrast materials • Three different oral contrast materials result in comparable CT image quality • Benefits for patients and medical imaging department.
MDCT distinguishing features of focal aortic projections (FAP) in acute clinical settings.
Valente, Tullio; Rossi, Giovanni; Lassandro, Francesco; Rea, Gaetano; Marino, Maurizio; Urciuolo, Salvatore; Tortora, Giovanni; Muto, Maurizio
2015-01-01
Focal aortic projections (FAP) are protrusion images of the contrast medium (focal contour irregularity, breaks in the intimal contour, outward lumen bulging or localized blood-filled outpouching) projecting beyond the aortic lumen in the aortic wall and are commonly seen on multidetector computed tomography (MDCT) scans of the chest and abdomen. FAP include several common and uncommon etiologies, which can be demonstrated both in the native aorta, mainly in acute aortic syndromes, and in the post-surgical aorta or after endovascular therapy. They are also found in some types of post-traumatic injuries and in impending rupture of the aneurysms. The expanding, routine use of millimetric or submillimetric collimation of current state-of-the-art MDCT scanners (16 rows and higher) all the time allows the identification and characterization of these small ulcer-like lesions or irregularities in the entire aorta, as either an incidental or expected finding, and provides detailed three-dimensional pictures of these pathologic findings. In this pictorial review, we illustrate the possible significance of FAP and the discriminating MDCT features that help to distinguish among different types of aortic protrusions and their possible evolution. Awareness of some related and distinctive radiologic features in FAP may improve our understanding of aortic diseases, provide further insight into the pathophysiology and natural history, and guide the appropriate management of these lesions.
Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsai, W.-L.; Tsai, I-C.; Lee Tain, E-mail: s841082@ym.edu.t
Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.
Monte: A compact and versatile multidetector system based on monolithic telescopes
NASA Astrophysics Data System (ADS)
Amorini, F.; Bonanno, A.; Cardella, G.; di Pietro, A.; Fallica, G.; Figuera, P.; Morea, A.; Musumarra, A.; Papa, M.; Pappalardo, G.; Pinto, A.; Rizzo, F.; Tian, W.; Tudisco, S.; Valvo, G.
2005-09-01
We present the characteristics of a new multidetector based on monolithic silicon telescopes: MONTE. By using high-energy ion implantation techniques, the ΔE and residual energy stages of such telescopes have been integrated on the same silicon chip, obtaining extremely thin ΔE stages of the order of 1 μm. This allowed one to obtain a very low charge identification energy threshold and a very good β background suppression in reactions induced by radioactive ion beams. The multidetector has a modular structure and can be assembled in different geometrical configurations according to experimental needs.
Farghadani, Maryam; Momeni, Mohammad; Hekmatnia, Ali; Momeni, Fateme; Baradaran Mahdavi, Mohammad Mehdi
2016-01-01
The celiac axis, superior mesenteric artery (SMA), and hepatic artery are the most important branches of abdominal aorta due to their vascularization field. The aim of our study was to evaluate the prevalence of different anatomical variation of celiac axis, SMA, hepatic artery, and its branches with multidetector computed tomography (MDCT) angiography of upper abdomen arteries. MDCT of 607 kidney donor and traumatic patients that referred to MDCT unit at Al Zahra Hospital in Isfahan from 2012 to 2015 were retrospectively evaluated. We excluded patients with history of abdominal vascular surgery and hepatic or pancreatic surgery. Computed tomography images of the patient were obtained with 64-row MDCT scanner and anatomical variations were analyzed. Three hundred and eighty-eight (63.9%) of the 607 patients had classic arterial anatomy and 219 (36.1%) patients had variant types. The most common type of variation was the origin of the right hepatic artery (RHA) from SMA (9.6%), and the next common variation was the origin of the left hepatic artery (LHA) from the left gastric artery (6.9%). Variations in the origin of the common hepatic artery (CHA) were seen in 16 (2.6%) patients. Buhler arc was identified in two patients. The RHA originated from the celiac axis in 11 (1.8%) patients and from the aorta in 8 (1.3%) patients. Trifurcation of CHA into gastroduodenal artery, RHA, and LHA was detected in 11 (1.8%) patients. The results of the present study showed that anatomical variation occurs in a high percentage of patients. Detection of these variations can guide surgical and radiological interventional planning.
Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria
2018-01-01
Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (<3,025 arbitrary units) compared with patients with high AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.
Baskerville, Jerry Ray; Herrick, John
2012-02-01
This study focuses on clinically assigned prospective estimated pretest probability and pretest perception of legal risk as independent variables in the ordering of multidetector computed tomographic (MDCT) head scans. Our primary aim is to measure the association between pretest probability of a significant finding and pretest perception of legal risk. Secondarily, we measure the percentage of MDCT scans that physicians would not order if there was no legal risk. This study is a prospective, cross-sectional, descriptive analysis of patients 18 years and older for whom emergency medicine physicians ordered a head MDCT. We collected a sample of 138 patients subjected to head MDCT scans. The prevalence of a significant finding in our population was 6%, yet the pretest probability expectation of a significant finding was 33%. The legal risk presumed was even more dramatic at 54%. These data support the hypothesis that physicians presume the legal risk to be significantly higher than the risk of a significant finding. A total of 21% or 15% patients (95% confidence interval, ±5.9%) would not have been subjected to MDCT if there was no legal risk. Physicians overestimated the probability that the computed tomographic scan would yield a significant result and indicated an even greater perceived medicolegal risk if the scan was not obtained. Physician test-ordering behavior is complex, and our study queries pertinent aspects of MDCT testing. The magnification of legal risk vs the pretest probability of a significant finding is demonstrated. Physicians significantly overestimated pretest probability of a significant finding on head MDCT scans and presumed legal risk. Copyright © 2012 Elsevier Inc. All rights reserved.
Isotani, Shuji; Shimoyama, Hirofumi; Yokota, Isao; Noma, Yasuhiro; Kitamura, Kousuke; China, Toshiyuki; Saito, Keisuke; Hisasue, Shin-ichi; Ide, Hisamitsu; Muto, Satoru; Yamaguchi, Raizo; Ukimura, Osamu; Gill, Inderbir S; Horie, Shigeo
2015-10-01
The predictive model of postoperative renal function may impact on planning nephrectomy. To develop the novel predictive model using combination of clinical indices with computer volumetry to measure the preserved renal cortex volume (RCV) using multidetector computed tomography (MDCT), and to prospectively validate performance of the model. Total 60 patients undergoing radical nephrectomy from 2011 to 2013 participated, including a development cohort of 39 patients and an external validation cohort of 21 patients. RCV was calculated by voxel count using software (Vincent, FUJIFILM). Renal function before and after radical nephrectomy was assessed via the estimated glomerular filtration rate (eGFR). Factors affecting postoperative eGFR were examined by regression analysis to develop the novel model for predicting postoperative eGFR with a backward elimination method. The predictive model was externally validated and the performance of the model was compared with that of the previously reported models. The postoperative eGFR value was associated with age, preoperative eGFR, preserved renal parenchymal volume (RPV), preserved RCV, % of RPV alteration, and % of RCV alteration (p < 0.01). The significant correlated variables for %eGFR alteration were %RCV preservation (r = 0.58, p < 0.01) and %RPV preservation (r = 0.54, p < 0.01). We developed our regression model as follows: postoperative eGFR = 57.87 - 0.55(age) - 15.01(body surface area) + 0.30(preoperative eGFR) + 52.92(%RCV preservation). Strong correlation was seen between postoperative eGFR and the calculated estimation model (r = 0.83; p < 0.001). The external validation cohort (n = 21) showed our model outperformed previously reported models. Combining MDCT renal volumetry and clinical indices might yield an important tool for predicting postoperative renal function.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papadakis, Antonios E.; Perisinakis, Kostas; Damilakis, John
2007-07-15
The purpose of this study was to assess the potential of angular on-line tube current modulation on dose reduction in pediatric and adult patients undergoing multidetector computed tomography (MDCT) examinations. Five physical anthropomorphic phantoms that simulate the average individual as neonate, 1-year-old, 5-year-old, 10-year-old, and adult were employed in the current study. Phantoms were scanned with the use of on-line tube current modulation (TCM). Percent dose reduction (%DR) factors achieved by applying TCM, were determined for standard protocols used for head and neck, shoulder, thorax, thorax and abdomen, abdomen, abdomen and pelvis, pelvis, and whole body examinations. A preliminary studymore » on the application of TCM in MDCT examinations of adult patients was performed to validate the results obtained in anthropomorphic phantoms. Dose reduction was estimated as the percentage difference of the modulated milliamperes for each scan and the preset milliamperes prescribed by the scan protocol. The dose reduction in children was found to be much lower than the corresponding reduction achieved for adults. For helical scans the %DR factors, ranged between 1.6% and 7.4% for the neonate, 2.9% and 8.7% for the 1-year old, 2% and 6% for the 5-year-old, 5% and 10.9% for the 10-year-old, and 10.4% and 20.7% for the adult individual. For sequential scans the corresponding %DR factors ranged between 1.3% and 6.7%, 4.5% and 11%, 4.2% and 6.6%, 6.4% and 12.3%, and 8.9% and 23.3%, respectively. Broader beam collimations are associated with decreased %DR factors, when other scanning parameters are held constant. TCM did not impair image noise. In adult patients, the %DR values were found to be in good agreement with the corresponding results obtained in the anthropomorphic adult phantom. In conclusion, on-line TCM may be considered as a valuable tool for reducing dose in routine CT examinations of pediatric and adult patients. However, the dose reduction achieved with TCM in neonates and young children was found to be lower than that obtained for adults. Therefore, on-line TCM should work as an additional means to reduce dose and should not replace other conventional means of reducing dose, especially in neonates and young children.« less
Qi, Rui; Zhou, Xiangping; Yu, Jianqun; Li, Zhenlin
2014-04-01
This study aims to explore the inferior adhesion of the renal fascia (RF), and the inferior connectivity of the perirenal spaces (PS) with multidetector computed tomography (MDCT), and to investigate the diagnostic value of CT for showing this anatomy. From May to July 2012, eighty-two patients with acute pancreatitis presented in our hospital were enrolled into this study and underwent contrast-enhanced CT scans. All the image data were used to perform three dimensional reconstruction to show the inferior attachment of RF and the inferior connectivity of PS. The fusion of anterior renal fascia (ARF) and posterior renal fascia (PRF) next to the plane of iliac fossa were found on the left in 71.95% (59/82) cases, and on the right in 75.61% (62/82). In these cases, bilateral perirenal spaces, and anterior and posterior pararenal spaces were not found to be connected with each other. No fusion of ARF and PRF below the level of bilateral kidneys occurred on the left side in 28.05% (23/82) cases and on the right side in 24.39% (20/82). In these patients, the PS extended to the extraperitoneal space of the pelvic cavity and further to the inguinal region, and bilateral anterior and posterior pararenal spaces were not found to be connected with each other. Three-dimensional reconstruction on contrast-enhanced MDCT could be a valuable procedure for depicting inferior attachment of RF, and the inferior connectivity of PS.
Selberherr, Andreas; Hörmann, Marcus; Prager, Gerhard; Riss, Philipp; Scheuba, Christian; Niederle, Bruno
2017-03-01
The purpose of this study was to demonstrate the high number of kidney stones in primary hyperparathyroidism (PHPT) and the low number of in fact "asymptomatic" patients. Forty patients with PHPT (28 female, 12 male; median age 58 (range 33-80) years; interquartile range 17 years [51-68]) without known symptoms of kidney stones prospectively underwent multidetector computed tomography (MDCT) and ultrasound (US) examinations of the urinary tract prior to parathyroid surgery. Images were evaluated for the presence and absence of stones, as well as for the number of stones and sizes in the long axis. The MDCT and US examinations were interpreted by two experienced radiologists who were blinded to all clinical and biochemical data. Statistical analysis was performed using the Wilcoxon signed-rank test. US revealed a total of 4 kidney stones in 4 (10 %) of 40 patients (median size 6.5 mm, interquartile range 11.5 mm). MDCT showed a total of 41 stones (median size was 3 mm, interquartile range 2.25 mm) in 15 (38 %) of 40 patients. The number of kidney stones detected with MDCT was significantly higher compared to US (p = 0.00124). MDCT is a highly sensitive method for the detection of "silent" kidney stones in patients with PHPT. By widely applying this method, the number of asymptomatic courses of PHPT may be substantially reduced. MDCT should be used primarily to detect kidney stones in PHPT and to exclude asymptomatic PHPT.
Norris, Joseph M; Kishikova, Lyudmila; Avadhanam, Venkata S; Koumellis, Panos; Francis, Ian S; Liu, Christopher S C
2015-08-01
To investigate the efficacy of 640-slice multidetector computed tomography (MDCT) for detecting osteo-odonto laminar resorption in the osteo-odonto-keratoprosthesis (OOKP) compared with the current standard 32-slice MDCT. Explanted OOKP laminae and bone-dentine fragments were scanned using 640-slice MDCT (Aquilion ONE; Toshiba) and 32-slice MDCT (LightSpeed Pro32; GE Healthcare). Pertinent comparisons including image quality, radiation dose, and scanning parameters were made. Benefits of 640-slice MDCT over 32-slice MDCT were shown. Key comparisons of 640-slice MDCT versus 32-slice MDCT included the following: percentage difference and correlation coefficient between radiological and anatomical measurements, 1.35% versus 3.67% and 0.9961 versus 0.9882, respectively; dose-length product, 63.50 versus 70.26; rotation time, 0.175 seconds versus 1.000 seconds; and detector coverage width, 16 cm versus 2 cm. Resorption of the osteo-odonto lamina after OOKP surgery can result in potentially sight-threatening complications, hence it warrants regular monitoring and timely intervention. MDCT remains the gold standard for radiological assessment of laminar resorption, which facilitates detection of subtle laminar changes earlier than the onset of clinical signs, thus indicating when preemptive measures can be taken. The 640-slice MDCT exhibits several advantages over traditional 32-slice MDCT. However, such benefits may not offset cost implications, except in rare cases, such as in young patients who might undergo years of radiation exposure.
Mandich Crovetto, D; Alonso Charterina, S; Jiménez López-Guarch, C; Pont Vilalta, M; Pérez Núñez, M; de Pablo Gafas, A; Escribano Subías, P
2016-01-01
To use multidetector computed tomography (MDCT) to evaluate the structural changes in the right heart and pulmonary arteries that occur in patients with severe pulmonary hypertension treated by double lung transplantation. This was a retrospective study of 21 consecutive patients diagnosed with severe pulmonary hypertension who underwent double lung transplantation at our center between 2010 and 2014. We analyzed the last MDCT study done before lung transplantation and the first MDCT study done after lung transplantation. We recorded the following variables: diameter of the pulmonary artery trunk, ratio of the diameter of the pulmonary artery trunk to the diameter of the ascending aorta, diameter of the right ventricle, ratio of the diameter of the left ventricle to the diameter of the right ventricle, and eccentricity index. Statistical analysis consisted of the comparison of the means of the variables recorded. In all cases analyzed, the MDCT study done a mean of 24±14 days after double lung transplantation showed a significant reduction in the size of the right heart chambers, with improved indices of ventricular interdependency index, and reduction in the size of the pulmonary artery trunk (p<0.001 for all the variables analyzed). Patients with pulmonary hypertension treated by double lung transplantation present early reverse remodeling of the changes in the structures of the right heart and pulmonary arterial tree. MDCT is useful for detecting these changes. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Takahashi, Masashi; Ohashi, Hirofumi
2013-06-01
Costello syndrome is a rare multiple congenital anomaly syndrome caused by heterozygous germline HRAS mutations, which is characterized by intellectual disability, growth retardation, distinctive facies, loose skin, cardiomyopathy and a preposition to malignancies. Although teeth abnormalities have been encountered in nearly two-thirds of the patients in literature, the evaluation tended to be limited to the extent which can be obtained from physical examination. We investigated detailed craniofacial, oral and dental findings in four patients with Costello syndrome. In this study, images reconstructed by multi-detector row computed tomography (MDCT) were used as substitutes for dental cast study and panoramic and lateral cephalometric radiograph studies to evaluate dental arches, tooth size, relationships between craniofacial and dental structures, and hypodontia. All four patients showed true/relative macrocephaly with facial bone hypoplasia and gingival hypertrophy. Occlusal attrition, malocclusion, small dental arches, microdontia, and convex face were noted in three patients. In addition, one patient showed dental caries, conic tooth and gingivitis, and another patient showed hypodontia. Our study suggests that craniofacial and dental abnormalities are common in Costello syndrome patients and comprehensive dental care should be provided from early infancy. To our knowledge, this is the first study of thorough craniofacial and dental evaluation by using MDCT in Costello syndrome. MDCT is a useful tool for precise evaluation of craniofacial and oral manifestations in patients with congenital anomaly/intellectual disability syndromes. © 2012 The Authors. Congenital Anomalies © 2012 Japanese Teratology Society.
Kim, Jong Gyu
2012-01-01
Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839
NASA Technical Reports Server (NTRS)
Biggerstaff, J. A. (Editor)
1985-01-01
Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.
Brewer, Amandaa K; Striegel, André M
2011-04-15
The string-of-pearls-type morphology is ubiquitous, manifesting itself variously in proteins, vesicles, bacteria, synthetic polymers, and biopolymers. Characterizing the size and shape of analytes with such morphology, however, presents a challenge, due chiefly to the ease with which the "strings" can be broken during chromatographic analysis or to the paucity of information obtained from the benchmark microscopy and off-line light scattering methods. Here, we address this challenge with multidetector hydrodynamic chromatography (HDC), which has the ability to determine, simultaneously, the size, shape, and compactness and their distributions of string-of-pearls samples. We present the quadruple-detector HDC analysis of colloidal string-of-pearls silica, employing static multiangle and quasielastic light scattering, differential viscometry, and differential refractometry as detection methods. The multidetector approach shows a sample that is broadly polydisperse in both molar mass and size, with strings ranging from two to five particles, but which also contains a high concentration of single, unattached "pearls". Synergistic combination of the various size parameters obtained from the multiplicity of detectors employed shows that the strings with higher degrees of polymerization have a shape similar to the theory-predicted shape of a Gaussian random coil chain of nonoverlapping beads, while the strings with lower degrees of polymerization have a prolate ellipsoidal shape. The HDC technique is contrasted experimentally with multidetector size-exclusion chromatography, where, even under extremely gentle conditions, the strings still degraded during analysis. Such degradation is shown to be absent in HDC, as evidenced by the fact that the molar mass and radius of gyration obtained by HDC with multiangle static light scattering detection (HDC/MALS) compare quite favorably to those determined by off-line MALS analysis under otherwise identical conditions. The multidetector HDC results were also comparable to those obtained by transmission electron microscopy (TEM). Unlike off-line MALS or TEM, however, multidetector HDC is able to provide complete particle analysis based on the molar mass, size, shape, and compactness and their distributions for the entire sample population in less than 20 min. © 2011 American Chemical Society
Chu, Zhi-gang; Yang, Zhi-gang; Dong, Zhi-hui; Chen, Tian-wu; Zhu, Zhi-yu; Shao, Heng
2011-01-01
OBJECTIVE: The features of earthquake-related head injuries may be different from those of injuries obtained in daily life because of differences in circumstances. We aim to compare the features of head traumas caused by the Sichuan earthquake with those of other common head traumas using multidetector computed tomography. METHODS: In total, 221 patients with earthquake-related head traumas (the earthquake group) and 221 patients with other common head traumas (the non-earthquake group) were enrolled in our study, and their computed tomographic findings were compared. We focused the differences between fractures and intracranial injuries and the relationships between extracranial and intracranial injuries. RESULTS: More earthquake-related cases had only extracranial soft tissue injuries (50.7% vs. 26.2%, RR = 1.9), and fewer cases had intracranial injuries (17.2% vs. 50.7%, RR = 0.3) compared with the non-earthquake group. For patients with fractures and intracranial injuries, there were fewer cases with craniocerebral injuries in the earthquake group (60.6% vs. 77.9%, RR = 0.8), and the earthquake-injured patients had fewer fractures and intracranial injuries overall (1.5±0.9 vs. 2.5±1.8; 1.3±0.5 vs. 2.1±1.1). Compared with the non-earthquake group, the incidences of soft tissue injuries and cranial fractures combined with intracranial injuries in the earthquake group were significantly lower (9.8% vs. 43.7%, RR = 0.2; 35.1% vs. 82.2%, RR = 0.4). CONCLUSION: As depicted with computed tomography, the severity of earthquake-related head traumas in survivors was milder, and isolated extracranial injuries were more common in earthquake-related head traumas than in non-earthquake-related injuries, which may have been the result of different injury causes, mechanisms and settings. PMID:22012045
Wielpütz, Mark O.; Weinheimer, Oliver; Eichinger, Monika; Wiebel, Matthias; Biederer, Jürgen; Kauczor, Hans-Ulrich; Heußel, Claus P.
2013-01-01
Background Histopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF. Methods Volumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subjected to dedicated software. The lung was segmented, low attenuation volumes below a threshold of -950 Hounsfield units were assigned to emphysema volume (EV), and the emphysema index was computed (EI). Results were correlated with forced expiratory volume in 1 s percent predicted (FEV1%), residual volume (RV), and RV/total lung capacity (RV/TLC). Results We show that EV was increased in CF (457±530 ml) compared to non-CF controls (78±90 ml) (P<0.01). EI was also increased in CF (7.7±7.5%) compared to the control group (1.2±1.4%) (P<0.05). EI correlated inversely with FEV1% (rs=-0.66), and directly with RV (rs=0.69) and RV/TLC (rs=0.47) in patients with CF (P<0.007), but not in non-CF controls. Emphysema in CF was detected from early adolescence (~13 years) and increased with age (rs=0.67, P<0.001). Conclusions Our results indicate that early onset emphysema detected by densitometry on chest MDCT is a characteristic pathology that contributes to airflow limitation and may serve as a novel endpoint for monitoring lung disease in CF. PMID:23991177
NASA Astrophysics Data System (ADS)
Mei, Kai; Kopp, Felix K.; Fehringer, Andreas; Pfeiffer, Franz; Rummeny, Ernst J.; Kirschke, Jan S.; Noël, Peter B.; Baum, Thomas
2017-03-01
The trabecular bone microstructure is a key to the early diagnosis and advanced therapy monitoring of osteoporosis. Regularly measuring bone microstructure with conventional multi-detector computer tomography (MDCT) would expose patients with a relatively high radiation dose. One possible solution to reduce exposure to patients is sampling fewer projection angles. This approach can be supported by advanced reconstruction algorithms, with their ability to achieve better image quality under reduced projection angles or high levels of noise. In this work, we investigated the performance of iterative reconstruction from sparse sampled projection data on trabecular bone microstructure in in-vivo MDCT scans of human spines. The computed MDCT images were evaluated by calculating bone microstructure parameters. We demonstrated that bone microstructure parameters were still computationally distinguishable when half or less of the radiation dose was employed.
Multidetector Scattering as a Probe of Local Structure in Disordered Phases
NASA Astrophysics Data System (ADS)
Clark, Noel A.; Ackerson, Bruce J.; Hurd, Alan J.
1983-05-01
The local translational structure of a two-dimensional colloidal liquid is observed by use of cross correlation of the intensity fluctuations of light scattered by the liquid through two different wave vectors. The utility of multidetector scattering in probing multipoint correlations in disordered phases is thereby demonstrated unambiguously.
NASA Astrophysics Data System (ADS)
Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang
2018-03-01
In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.
Akhilesh, Philomina; Kulkarni, Arti R; Jamhale, Shramika H; Sharma, S D; Kumar, Rajesh; Datta, D
2017-04-25
The purpose of this study was to estimate eye lens dose during brain scans in 16-, 64-, 128- and 256-slice multidetector computed tomography (CT) scanners in helical acquisition mode and to test the feasibility of using radiochromic film as eye lens dosemeter during CT scanning. Eye lens dose measurements were performed using Gafchromic XR-QA2 film on a polystyrene head phantom designed with outer dimensions equivalent to the head size of a reference Indian man. The response accuracy of XR-QA2 film was validated by using thermoluminescence dosemeters. The eye lens dose measured using XR-QA2 film on head phantom for plain brain scanning in helical mode ranged from 43.8 to 45.8 mGy. The XR-QA2 film measured dose values were in agreement with TLD measured dose values within a maximum variation of 8.9%. The good correlation between the two data sets confirms the viability of using XR-QA2 film for eye lens dosimetry. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferro, Carlo; Rossi, Umberto G., E-mail: urossi76@hotmail.com; Bovio, Giulio
2007-09-15
A patient was admitted because of severe abdominal pain, anorexia, and intestinal bleeding. Contrast-enhanced multidetector computed tomography demonstrated acute portal and superior mesenteric vein thrombosis (PSMVT). The patient was treated percutaneously with transjugular intrahepatic portosystemic shunt (TIPS), mechanical aspiration thrombectomy, and direct thrombolysis, and 1 week after the procedure, complete patency of the portal and superior mesenteric veins was demonstrated. TIPS, mechanical aspiration thrombectomy, and direct thrombolysis together are promising endovascular techniques for the treatment of symptomatic acute PSMVT.
Hirakuri, Ayaka; Numasawa, Kanako; Takeishi, Hideki; Satomura, Minato; Takeda, Hiromitsu; Harada, Kuniaki; Asanuma, Osamu; Sakata, Motomichi
2012-01-01
The exposure of the eye lens caused by multi-detector row computed tomography (MDCT) of the temporal bone is a serious problem. Our aim was to evaluate the radiation dose to the eye lens by different scan baselines (orbitomeatal line; OML, acanthiomeatal line; AML) and examine the difference of the depiction of the temporal bone structures. Measurement of the exposure to the eye lens was performed by means of MDCT of the temporal bone with a radio-photoluminescence glass dosimeter using a rand phantom. Moreover, we studied only one volunteer (58-year-old male) who had no symptom and was not suspected of having any ear abnormalities with a two scan baseline. Visualization of the major anatomical structures of the temporal bone (the tympanic portion of the facial nerve canal, the body of the incus, stapes superstructures, vestibule etc.) was performed on the volunteer. The average absorbed dose was 6.42 mGy by the OML and 1.59 mGy by the AML, respectively. With regard to visualization of the temporal bone structures, all structures were of equal quality with the two scan baseline. With the AML line, the radiation dose to the eye lens was reduced to 75%. Therefore, the authors recommended an AML for use for MDCT of the temporal bone. In clinical practice, the optimization of scanning factor (kVp, mAs etc.) and the use of the radio-protection should be implemented for radiation dose reduction of the eye lens by MDCT of the temporal bone.
Çiledağ, Nazan; Arda, Kemal; Arıbaş, Bilgin Kadri; Tekgündüz, Ali Irfan Emre; Altuntaş, Fevzi
2012-01-01
Objective: To evaluate vessel involvement and the role of multidetector computed tomography (MDCT) in the earlydiagnosis of invasive pulmonary aspergillosis (IPA) in patients with febrile neutropenia and antibiotic-resistant feverundergoing autologous bone morrow transplantation. Material and Methods: In all, 74 pulmonary MDCT examinations in 37 consecutive hematopoietic stem celltransplantation patients with febrile neutropenia and clinically suspected IPA were retrospectively evaluated. Results: Diagnosis of IPA was based on Fungal Infections Cooperative Group, and National Institute of Allergy andInfectious Diseases Mycoses Study Consensus Group criteria. In all, 0, 14, and 11 patients were diagnosed as proven,probable, and possible IPA, respectively. Among the 25 patients accepted as probable and possible IPA, all had pulmonaryMDCT findings consistent with IPA. The remaining 12 patients were accepted as having fever of unknown origin (FUO)and had patent vessels based on MDCT findings.In the patients with probable and possible IPA, 72 focal pulmonary lesions were observed; in 41 of the 72 (57%) lesionsvascular occlusion was noted and the CT halo sign was observed in 25 of these 41 (61%) lesions. Resolution of feveroccurred following antifungal therapy in 19 (76%) of the 25 patients with probable and possible IPA. In all, 6 (25%)of the patients diagnosed as IPA died during follow-up. Transplant-related mortality 100 d post transplant in patientswith IPA and FUO was 24% and 0%, respectively. Conclusion: In conclusion, MDCT has a potential role in the early diagnosis of IPA via detection of vessel occlusion. PMID:24744620
Le Couteulx, S; Caudron, J; Dubourg, B; Cauchois, G; Dupré, M; Michelin, P; Durand, E; Eltchaninoff, H; Dacher, J-N
2018-05-01
To evaluate intra- and inter-observer variability of multidetector computed tomography (MDCT) sizing of the aortic annulus before transcatheter aortic valve replacement (TAVR) and the effect of observer experience, aortic valve calcification and image quality. MDCT examinations of 52 consecutive patients with tricuspid aortic valve (30 women, 22 men) with a mean age of 83±7 (SD) years (range: 64-93 years) were evaluated retrospectively. The maximum and minimum diameters, area and circumference of the aortic annulus were measured twice at diastole and systole with a standardized approach by three independent observers with different levels of experience (expert [observer 1]; resident with intensive 6 months practice [observer 2]; trained resident with starting experience [observer 3]). Observers were requested to recommend the valve prosthesis size. Calcification volume of the aortic valve and signal to noise ratio were evaluated. Intra- and inter-observer reproducibility was excellent for all aortic annulus dimensions, with an intraclass correlation coefficient ranging respectively from 0.84 to 0.98 and from 0.82 to 0.97. Agreement for selection of prosthesis size was almost perfect between the two most experienced observers (k=0.82) and substantial with the inexperienced observer (k=0.67). Aortic valve calcification did not influence intra-observer reproducibility. Image quality influenced reproducibility of the inexperienced observer. Intra- and inter-observer variability of aortic annulus sizing by MDCT is low. Nevertheless, the less experienced observer showed lower reliability suggesting a learning curve. Copyright © 2017. Published by Elsevier Masson SAS.
Multidetector computed tomography urography for diagnosing upper urinary tract urothelial tumour.
Cowan, Nigel C; Turney, Ben W; Taylor, Nia J; McCarthy, Catherine L; Crew, Jeremy P
2007-06-01
To evaluate multidetector computed tomography urography (MDCTU) for diagnosing upper urinary tract (UUT) urothelial tumour by comparison with retrograde ureteropyelography (RUP). MDCTU and RUP were used in a selected series of adult patients presenting with haematuria. Entry criteria were based on findings on intravenous urography and were chosen to ensure a high prevalence of UUT urothelial tumour to allow a valid retrospective comparison of the diagnostic techniques. MDCTU and RUP studies were scored for the presence and absence of UUT urothelial tumour by two radiologists, retrospectively and independently, and while unaware of the demographic and clinical information. The reference standards were the histopathology and clinical follow-up. MDCTU and RUP were used in 106 patients over a 24-month period. RUP was attempted in 151 of 212 UUTs; the corresponding MDCTU for each UUT was reviewed. MDCTU was a true-positive (TP) for urothelial tumour in 31, true-negative (TN) in 111, false-positive (FP) in eight and false-negative (FN) in one UUT, giving a sensitivity of 0.97, a specificity of 0.93, a positive predictive value (PPV) of 0.79 and a negative PV (NPV) of 0.99. RUP was technically successful and diagnostic in 96% of the UUTs (143/151). For diagnosing urothelial tumour, RUP was TP in 26, TN in 112, FP in four and FN in one UUT, giving a sensitivity of 0.97, specificity of 0.93, a PPV of 0.79 and NPV of 0.99. This study validates quantitatively the use of MDCTU for diagnosing UUT urothelial tumour.
Beliaev, Andrei M; Barber, P Alan; Marshall, Roger J; Civil, Ian
2014-06-01
Blunt cerebrovascular injury (BCVI) occurs in 0.2-2.7% of blunt trauma patients and has up to 30% mortality. Conventional screening does not recognize up to 20% of BCVI patients. To improve diagnosis of BCVI, both an expanded battery of screening criteria and a multi-detector computed tomography angiography (CTA) have been suggested. The aim of this study is to investigate whether the use of CTA restricted to the Denver protocol screen-positive patients would reduce the unnecessary use of CTA as a pre-emptive screening tool. This is a registry-based study of blunt trauma patients admitted to Auckland City Hospital from 1998 to 2012. The diagnosis of BCVI was confirmed or excluded with CTA, magnetic resonance angiography and, if these imaging were non-conclusive, four-vessel digital subtraction angiography. Thirty (61%) BCVI and 19 (39%) non-BCVI patients met eligibility criteria. The Denver protocol applied to our cohort of patients had a sensitivity of 97% (95% confidence interval (CI): 83-100%) and a specificity of 42% (95% CI: 20-67%). With a prevalence of BCVI in blunt trauma patients of 0.2% and 2.7%, post-test odds of a screen-positive test were 0.03 (95% CI: 0.002-0.005) and 0.046 (95% CI: 0.314-0.068), respectively. Application of the CTA to the Denver protocol screen-positive trauma patients can decrease the use of CTA as a pre-emptive screening tool by 95-97% and reduces its hazards. © 2013 Royal Australasian College of Surgeons.
Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana
2013-08-01
Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05) in favor of better display of injury by MDCT examination. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.
Ishii, Namiko; Sakuma, Ayaka; Makino, Yohsuke; Torimitsu, Suguru; Yajima, Daisuke; Inokuchi, Go; Motomura, Ayumi; Chiba, Fumiko; Hoshioka, Yumi; Iwase, Hirotaro; Saitoh, Hisako
2016-09-01
The purpose of this study was to determine the incidence of three-rooted mandibular first molars in a contemporary Japanese population using multidetector computed tomography (MDCT) and examine whether this characteristic root form may be useful for identification purposes. Prior to their forensic autopsies, we obtained MDCT scans of 365 cadavers (255 males, 110 females) with mandibular first molars on both sides. Altogether, 730 mandibular first molars were examined morphologically on reconstructed CT images, and the incidence of three-rooted molars was recorded. The results were analyzed statistically to determine sex and left-right differences using the chi-square test. In all, 189 (25.9%) of the 730 mandibular first molars had three roots: 79 (31.0%) in the 255 males and 35 (31.8%) in the 110 females. No statistically significant difference was found between the sexes. In the 39 individuals who had unilateral three-rooted mandibular first molars, 7 (17.9%) were on the left side and 32 (82.1%) were on the right side, indicating a statistically significant predominance on the right side. The incidence of three-rooted mandibular first molars in contemporary Japanese individuals was 25.9%, with no statistically significant sex difference, but in the case of unilateral three-rooted teeth, with a statistically significant predominance on the right side. Our study found that Japanese and northeastern Asians have a high incidence of the three-rooted mandibular first molars among individuals of Mongolian origin; this finding may be a useful screening tool for identification of unknown individuals. Copyright © 2016. Published by Elsevier Ireland Ltd.
Savić, Živorad N.; Soldatović, Ivan I.; Brajović, Milan D.; Pavlović, Aleksandra M.; Mladenović, Dušan R.; Škodrić-Trifunović, Vesna D.
2011-01-01
The increased thickness of the carotid wall >1 mm is a significant predictor of coronary and cerebrovascular diseases. The purpose of our study was to assess the agreement between multidetector row computed tomography angiography (MDCTA) in measuring carotid artery wall thickness (CAWT) and color Doppler ultrasound (CD-US) in measuring intimae-media thickness (IMT). Eighty-nine patients (aged 35–81) were prospectively analyzed using a 64-detector MDCTA and a CD-US scanner. Continuous data were described as the mean value ± standard deviation, and were compared using the Mann–Whitney U test. A p value <0.05 was considered significant. Bland–Altman statistics were employed to measure the agreement between MDCTA and CD-US. CAWT ranged from 0.62 to 1.60 mm, with a mean value of 1.09 mm. IMT ranged from 0.60 to 1.55 mm, with a mean value of 1.06 mm. We observed an excellent agreement between CD-US and MDCTA in the evaluation of the common carotid artery thickness, with a bias between methods of 0.029 mm (which is a highly statistically important difference of absolute values [t = 43.289; p < 0.01] obtained by paired T test), and limits of agreement from 0.04 to 0.104. Pearson correlation coefficient was 0.9997 (95% CI 0.9996–0.9998; p < 0.01). We conclude that there is an excellent correlation between CAWT and IMT measurements obtained with the MDCTA and CD-US. PMID:22224072
Association between arterial calcifications and nonlacunar and lacunar ischemic strokes.
van Dijk, Anouk C; Fonville, Susanne; Zadi, Taihra; van Hattem, Antonius M G; Saiedie, Ghesrouw; Koudstaal, Peter J; van der Lugt, Aad
2014-03-01
Nonlacunar cerebral infarcts are presumed to be caused by thromboembolism from the heart or extracranial arteries, whereas lacunar infarcts are thought to be caused by small vessel disease. We investigated to what extent arterial calcifications differ between nonlacunar and lacunar ischemic strokes. We studied 820 consecutive patients with transient ischemic attack or ischemic stroke in the anterior circulation who underwent multidetector computed tomography angiography and had no rare cause of stroke. The presence of likely cardioembolic pathogenesis was determined according to the Trial of Org 10172 in Acute Stroke Treatment criteria. The remaining 708 patients were categorized as nonlacunar or lacunar strokes, either transient ischemic attacks or strokes, based on clinical symptoms corrected by brain imaging results. We measured volume of calcifications in the aortic arch, symptomatic extracranial and intracranial carotid artery using multidetector computed tomography angiography. The difference in calcifications between nonlacunar and lacunar strokes was assessed with a multivariable logistic regression analysis. We adjusted for degree of symptomatic carotid artery stenosis and cardiovascular risk factors. We found an independent association between volume of aortic arch calcifications and nonlacunar ischemic strokes (adjusted odds ratio [95% confidence interval], 1.11 [1.02-1.21]). No independent associations between extracranial and intracranial carotid artery calcifications and nonlacunar strokes were present. The only difference we found between nonlacunar and lacunar strokes was a higher calcification volume in the aortic arch in nonlacunar strokes. Our findings only partially confirm the notion of distinct etiologies and suggest that the potential role of other plaque components, plaque morphology, and aortic arch calcifications in ischemic stroke subtypes awaits further evaluation.
De Maeseneer, M; Buls, N; Cleeren, N; Lenchik, L; De Mey, J
2006-01-01
We present an unusual application of multidetector CT and shaded surface rendering in the investigation of a soil sample, containing an ancient Roman bronze bowl. The CT findings were of fundamental importance in helping the archaeologists study the bronze bowl from the soil sample.
Koopmann, Mario; Weiss, Daniel; Steiger, Matthias; Elges, Sandra; Rudack, Claudia; Stenner, Markus
2016-11-01
The objective of this study is to analyze the accuracy of computed tomography in detecting malignant thyroid cartilage invasion. In a retrospective chart review, 120 patients with carcinoma of the larynx and hypopharynx underwent computed tomography before total laryngectomy. These data were compared with the histological specimens. Multidetector computed tomography (MDCT) scan had a positive predictive value (PPV) of 76 % and a negative predictive value (NPV) of 69 %. The specificity of MDCT was 89 % and sensitivity was 46 %. Comparison between radiologic suspected cartilage invasion and histologic results showed a significant correlation (p < 0.02). We found no significant impact of cartilage invasion concerning survival rates (5-year overall survival p = 0.683; 5-year disease-free survival p = 0.711). Preoperative CT scan is an important instrument in detecting neoplastic cartilage invasion.
CPU timing routines for a CONVEX C220 computer system
NASA Technical Reports Server (NTRS)
Bynum, Mary Ann
1989-01-01
The timing routines available on the CONVEX C220 computer system in the Structural Mechanics Division (SMD) at NASA Langley Research Center are examined. The function of the timing routines, the use of the timing routines in sequential, parallel, and vector code, and the interpretation of the results from the timing routines with respect to the CONVEX model of computing are described. The timing routines available on the SMD CONVEX fall into two groups. The first group includes standard timing routines generally available with UNIX 4.3 BSD operating systems, while the second group includes routines unique to the SMD CONVEX. The standard timing routines described in this report are /bin/csh time,/bin/time, etime, and ctime. The routines unique to the SMD CONVEX are getinfo, second, cputime, toc, and a parallel profiling package made up of palprof, palinit, and palsum.
Usui, Akihito; Kawasumi, Yusuke; Hosokai, Yoshiyuki; Kozakai, Masataka; Saito, Haruo; Funayama, Masato
2016-01-01
Gunshot injury has always been an important field of investigation in postmortem forensic radiology. The localization and retrieval of the bullet and of potentially important fragments are vital to these cases. Using postmortem multidetector-row computed tomography (MDCT) prior to forensic autopsy, we sought to illustrate the importance of this modality in the noninvasive characterization of gunshot wounds. We obtained and analyzed MDCT images in three cases of gunshot wounds (accidental close-range shotgun shooting, suicidal contact gunshot to the head and accidental long-range buckshot shooting). We discuss the value of postmortem MDCT findings in gunshot wound cases by comparing with forensic autopsy findings in Japan, a developing country with miserably low autopsy rate. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Bardo, Dianna M E; Brown, Paul
2008-08-01
Cardiac MDCT is here to stay. And, it is more than just imaging coronary arteries. Understanding the differences in and the benefits of one CT scanner from another will help you to optimize the capabilities of the scanner, but requires a basic understanding of the MDCT imaging physics.This review provides key information needed to understand the differences in the types of MDCT scanners, from 64 - 320 detectors, flat panels, single and dual source configurations, step and shoot prospective and retrospective gating, and how each factor influences radiation dose, spatial and temporal resolution, and image noise.
Radiology of pancreatic neoplasms: An update
de la Santa, Luis Gijón; Retortillo, José Antonio Pérez; Miguel, Ainhoa Camarero; Klein, Lea Marie
2014-01-01
Diagnostic imaging is an important tool to evaluate pancreatic neoplasms. We describe the imaging features of pancreatic malignancies and their benign mimics. Accurate detection and staging are essential for ensuring appropriate selection of patients who will benefit from surgery and for preventing unnecessary surgeries in patients with unresectable disease. Ultrasound, multidetector computed tomography with multiplanar reconstruction and magnetic resonance imaging can help to do a correct diagnosis. Radiologists should be aware of the wide variety of anatomic variants and pathologic conditions that may mimic pancreatic neoplasms. The knowledge of the most important characteristic key findings may facilitate the right diagnosis. PMID:25232458
Radiology of pancreatic neoplasms: An update.
de la Santa, Luis Gijón; Retortillo, José Antonio Pérez; Miguel, Ainhoa Camarero; Klein, Lea Marie
2014-09-15
Diagnostic imaging is an important tool to evaluate pancreatic neoplasms. We describe the imaging features of pancreatic malignancies and their benign mimics. Accurate detection and staging are essential for ensuring appropriate selection of patients who will benefit from surgery and for preventing unnecessary surgeries in patients with unresectable disease. Ultrasound, multidetector computed tomography with multiplanar reconstruction and magnetic resonance imaging can help to do a correct diagnosis. Radiologists should be aware of the wide variety of anatomic variants and pathologic conditions that may mimic pancreatic neoplasms. The knowledge of the most important characteristic key findings may facilitate the right diagnosis.
Imaging of pannus formation in patients with mechanical heart valves.
Gündüz, Sabahattin; Özkan, Mehmet; Yesin, Mahmut
2015-11-26
Patient-prosthesis mismatch (PPM) should be recognized in patients with elevated transprosthetic gradients but without leaflet immobility, since the treatment strategy may differ in either etiology. However, thrombus and/or pannus formation should be excluded before a diagnosis of PPM is made. Particularly, pannus formation may not be diagnosed with 2-dimensional transesophageal echocardiography. Electrocardiographically gated 64-section multidetector computed tomography (MDCT) may be a promising tool in diagnosing or excluding pannus formation. Our report underlines the utility of MDCT in this regard and also emphasizes the importance of recognition of PPM as a differential diagnosis in such patients.
Imaging of pannus formation in patients with mechanical heart valves
Gündüz, Sabahattin; Özkan, Mehmet; Yesin, Mahmut
2015-01-01
Patient-prosthesis mismatch (PPM) should be recognized in patients with elevated transprosthetic gradients but without leaflet immobility, since the treatment strategy may differ in either etiology. However, thrombus and/or pannus formation should be excluded before a diagnosis of PPM is made. Particularly, pannus formation may not be diagnosed with 2-dimensional transesophageal echocardiography. Electrocardiographically gated 64-section multidetector computed tomography (MDCT) may be a promising tool in diagnosing or excluding pannus formation. Our report underlines the utility of MDCT in this regard and also emphasizes the importance of recognition of PPM as a differential diagnosis in such patients. PMID:26635931
Mei, Kai; Kopp, Felix K; Bippus, Rolf; Köhler, Thomas; Schwaiger, Benedikt J; Gersing, Alexandra S; Fehringer, Andreas; Sauter, Andreas; Münzel, Daniela; Pfeiffer, Franz; Rummeny, Ernst J; Kirschke, Jan S; Noël, Peter B; Baum, Thomas
2017-12-01
Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.
Methods for radiation detection and characterization using a multiple detector probe
Akers, Douglas William; Roybal, Lyle Gene
2014-11-04
Apparatuses, methods, and systems relating to radiological characterization of environments are disclosed. Multi-detector probes with a plurality of detectors in a common housing may be used to substantially concurrently detect a plurality of different radiation activities and types. Multiple multi-detector probes may be used in a down-hole environment to substantially concurrently detect radioactive activity and contents of a buried waste container. Software may process, analyze, and integrate the data from the different multi-detector probes and the different detector types therein to provide source location and integrated analysis as to the source types and activity in the measured environment. Further, the integrated data may be used to compensate for differential density effects and the effects of radiation shielding materials within the volume being measured.
The impact of manual threshold selection in medical additive manufacturing.
van Eijnatten, Maureen; Koivisto, Juha; Karhu, Kalle; Forouzanfar, Tymour; Wolff, Jan
2017-04-01
Medical additive manufacturing requires standard tessellation language (STL) models. Such models are commonly derived from computed tomography (CT) images using thresholding. Threshold selection can be performed manually or automatically. The aim of this study was to assess the impact of manual and default threshold selection on the reliability and accuracy of skull STL models using different CT technologies. One female and one male human cadaver head were imaged using multi-detector row CT, dual-energy CT, and two cone-beam CT scanners. Four medical engineers manually thresholded the bony structures on all CT images. The lowest and highest selected mean threshold values and the default threshold value were used to generate skull STL models. Geometric variations between all manually thresholded STL models were calculated. Furthermore, in order to calculate the accuracy of the manually and default thresholded STL models, all STL models were superimposed on an optical scan of the dry female and male skulls ("gold standard"). The intra- and inter-observer variability of the manual threshold selection was good (intra-class correlation coefficients >0.9). All engineers selected grey values closer to soft tissue to compensate for bone voids. Geometric variations between the manually thresholded STL models were 0.13 mm (multi-detector row CT), 0.59 mm (dual-energy CT), and 0.55 mm (cone-beam CT). All STL models demonstrated inaccuracies ranging from -0.8 to +1.1 mm (multi-detector row CT), -0.7 to +2.0 mm (dual-energy CT), and -2.3 to +4.8 mm (cone-beam CT). This study demonstrates that manual threshold selection results in better STL models than default thresholding. The use of dual-energy CT and cone-beam CT technology in its present form does not deliver reliable or accurate STL models for medical additive manufacturing. New approaches are required that are based on pattern recognition and machine learning algorithms.
Tung, Matthew K; Cameron, James D; Casan, Joshua M; Crossett, Marcus; Troupis, John M; Meredith, Ian T; Seneviratne, Sujith K
2013-01-01
Minimization of radiation exposure remains an important subject that occurs in parallel with advances in scanner technology. We report our experience of evolving radiation dose and its determinants after the introduction of 320-multidetector row cardiac CT within a single tertiary cardiology referral service. Four cohorts of consecutive patients (total 525 scans), who underwent cardiac CT at defined time points as early as 2008, are described. These include a cohort just after scanner installation, after 2 upgrades of the operating system, and after introduction of an adaptive iterative image reconstruction algorithm. The proportions of nondiagnostic coronary artery segments and studies with nondiagnostic segments were compared between cohorts. Significant reductions were observed in median radiation doses in all cohorts compared with the initial cohort (P < .001). Median dose-length product fell from 944 mGy · cm (interquartile range [IQR], 567.3-1426.5 mGy · cm) to 156 mGy · cm (IQR, 99.2-265.0 mGy · cm). Although the proportion of prospectively triggered scans has increased, reductions in radiation dose have occurred independently of distribution of scan formats. In multiple regression that combined all groups, determinants of dose-length product were tube output, the number of cardiac cycles scanned, tube voltage, scan length, scan format, body mass index, phase width, and heart rate (adjusted R(2) = 0.85, P < .001). The proportion of nondiagnostic coronary artery segments was slightly increased in group 4 (2.9%; P < .01). While maintaining diagnostic quality in 320-multidetector row cardiac CT, the radiation dose has decreased substantially because of a combination of dose-reduction protocols and technical improvements. Continued minimization of radiation dose will increase the potential for cardiac CT to expand as a cardiac imaging modality. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Multi-detector CT features of acute intestinal ischemia and their prognostic correlations.
Moschetta, Marco; Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe
2014-05-28
Acute intestinal ischemia is an abdominal emergency occurring in nearly 1% of patients presenting with acute abdomen. The causes can be occlusive or non occlusive. Early diagnosis is important to improve survival rates. In most cases of late or missed diagnosis, the mortality rate from intestinal infarction is very high, with a reported value ranging from 60% to 90%. Multi-detector computed tomography (MDCT) is a fundamental imaging technique that must be promptly performed in all patients with suspected bowel ischemia. Thanks to the new dedicated reconstruction program, its diagnostic potential is much improved compared to the past and currently it is superior to that of any other noninvasive technique. The increased spatial and temporal resolution, high-quality multi-planar reconstructions, maximum intensity projections, vessel probe, surface-shaded volume rending and tissue transition projections make MDCT the gold standard for the diagnosis of intestinal ischemia, with reported sensitivity, specificity, positive and negative predictive values of 64%-93%, 92%-100%, 90%-100% and 94%-98%, respectively. MDCT contributes to appropriate treatment planning and provides important prognostic information thanks to its ability to define the nature and extent of the disease. The purpose of this review is to examine the diagnostic and prognostic role of MDCT in bowel ischemia with special regard to the state of art new reconstruction software.
Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G
2011-01-01
Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.
Takakuwa, Kevin M; Halpern, Ethan J; Shofer, Frances S
2011-02-01
The study aimed to examine time and imaging costs of 2 different imaging strategies for low-risk emergency department (ED) observation patients with acute chest pain or symptoms suggestive of acute coronary syndrome. We compared a "triple rule-out" (TRO) 64-section multidetector computed tomography protocol with nuclear stress testing. This was a prospective observational cohort study of consecutive ED patients who were enrolled in our chest pain observation protocol during a 16-month period. Our standard observation protocol included a minimum of 2 sets of cardiac enzymes at least 6 hours apart followed by a nuclear stress test. Once a week, observation patients were offered a TRO (to evaluate for coronary artery disease, thoracic dissection, and pulmonary embolus) multidetector computed tomography with the option of further stress testing for those patients found to have evidence of coronary artery disease. We analyzed 832 consecutive observation patients including 214 patients who underwent the TRO protocol. Mean total length of stay was 16.1 hours for TRO patients, 16.3 hours for TRO plus other imaging test, 22.6 hours for nuclear stress testing, 23.3 hours for nuclear stress testing plus other imaging tests, and 23.7 hours for nuclear stress testing plus TRO (P < .0001 for TRO and TRO + other test compared to stress test ± other test). Mean imaging times were 3.6, 4.4, 5.9, 7.5, and 6.6 hours, respectively (P < .05 for TRO and TRO + other test compared to stress test ± other test). Mean imaging costs were $1307 for TRO patients vs $945 for nuclear stress testing. Triple rule-out reduced total length of stay and imaging time but incurred higher imaging costs. A per-hospital analysis would be needed to determine if patient time savings justify the higher imaging costs. Copyright © 2011 Elsevier Inc. All rights reserved.
2011-01-01
Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT) was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG)-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional information can be of help with regard to improved diagnoses of thoracic anomalies and the planning of surgical interventions. PMID:21943366
Jones, Jeryl C; Appt, Susan E; Werre, Stephen R; Tan, Joshua C; Kaplan, Jay R
2010-06-01
The purpose of this study was to validate low radiation dose, contrast-enhanced, multi-detector computed tomography (MDCT) as a non-invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known-volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32-slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand-traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702+/-SD 0.504 cc and the mean actual volume was 0.743+/-SD 0.526 cc. Ovary mean CT volume was 0.258+/-SD 0.159 cc and mean water displacement volume was 0.257+/-SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non-invasive technique for measuring the ovarian volume in macaques.
A MAP fixed-point, packing-unpacking routine for the IBM 7094 computer
Robert S. Helfman
1966-01-01
Two MAP (Macro Assembly Program) computer routines for packing and unpacking fixed point data are described. Use of these routines with Fortran IV Programs provides speedy access to quantities of data which far exceed the normal storage capacity of IBM 7000-series computers. Many problems that could not be attempted because of the slow access-speed of tape...
Razek, Ahmed Abdel Khalek Abdel; Ezzat, Amany; Azmy, Emad; Tharwat, Nehal
2013-08-01
The authors evaluated the role of whole-body 64-slice multidetector computed tomography (WB-MDCT) in treatment planning for multiple myeloma. This was a prospective study of 28 consecutive patients with multiple myeloma (19 men, nine women; age range, 51-73 years; mean age, 60 years) who underwent WB-MDCT and conventional radiography (CR) of the skeleton. The images were interpreted for the presence of bony lesions, medullary lesions, fractures and extraosseous lesions. We evaluated any changes in treatment planning as a result of WB-MDCT findings. WB-MDCT was superior to CR for detecting bony lesions (p=0.001), especially of the spine (p=0.001) and thoracic cage (p=0.006). WB-MDCT upstaged 14 patients, with a significant difference in staging (p=0.002) between WB-MDCT and CR. Medullary involvement either focal (n=6) or diffuse (n=3) had a positive correlation with the overall score (r=0.790) and stage (r=0.618) of disease. Spine fractures were better detected at WB-MDCT (n=4) than at CR (n=2). Extraosseous soft tissue lesions (n=7) were detected only at WB-MDCT. Findings detected at the WB-MDCT led to changes in the patient's treatment plan in 39% of cases. Upstaging of seven patients (25%) altered the medical treatment plan, and four of 28 (14%) patients required additional radiotherapy (7%) and vertebroplasty (7%). We conclude that WB-MDCT has an impact on treatment planning and prognosis in patients with multiple myeloma, as it has high rate of detecting cortical and medullary bone lesions, spinal fracture and extraosseous lesions. This information may alter treatment planning in multiple myeloma due to disease upstaging and detection of spine fracture and extraosseous spinal lesions.
Markers of Vascular Perturbation Correlate with Airway Structural Change in Asthma
Kruger, Stanley J.; Schiebler, Mark L.; Evans, Michael D.; Sorkness, Ronald L.; Denlinger, Loren C.; Busse, William W.; Jarjour, Nizar N.; Montgomery, Robert R.; Mosher, Deane F.; Fain, Sean B.
2013-01-01
Rationale: Air trapping and ventilation defects on imaging are characteristics of asthma. Airway wall thickening occurs in asthma and is associated with increased bronchial vascularity and vascular permeability. Vascular endothelial cell products have not been explored as a surrogate to mark structural airway changes in asthma. Objectives: Determine whether reporters of vascular endothelial cell perturbation correlate with airway imaging metrics in patients with asthma of varying severity. Methods: Plasma from Severe Asthma Research Program subjects was analyzed by ELISAs for soluble von Willebrand factor mature protein (VWF:Ag) and propeptide (VWFpp), P-selectin, and platelet factor 4. Additional subjects were analyzed over 48 hours after whole-lung antigen challenge. We calculated ventilation defect volume by hyperpolarized helium-3 magnetic resonance imaging and areas of low signal density by multidetector computed tomography (less than −856 Hounsfield units [HU] at functional residual capacity and −950 HU at total lung capacity [TLC]). Measurements and Main Results: VWFpp and VWFpp/Ag ratio correlated with and predicted greater percentage defect volume on hyperpolarized helium-3 magnetic resonance imaging. P-selectin correlated with and predicted greater area of low density on chest multidetector computed tomography less than −950 HU at TLC. Platelet factor 4 did not correlate. Following whole-lung antigen challenge, variation in VWFpp, VWFpp/Ag, and P-selectin among time-points was less than that among subjects, indicating stability and repeatability of the measurements. Conclusions: Plasma VWFpp and P-selectin may be useful as surrogates of functional and structural defects that are evident on imaging. The results raise important questions about why VWFpp and P-selectin are associated specifically with different imaging abnormalities. PMID:23855693
Ianniello, Stefania; Di Giacomo, Vincenza; Sessa, Barbara; Miele, Vittorio
2014-09-01
Combined clinical examination and supine chest radiography have shown low accuracy in the assessment of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room. The aim of our study was to evaluate the diagnostic accuracy of extended-focused assessment with sonography in trauma (e-FAST), in the diagnosis of pneumothorax, compared with the results of multidetector computed tomography (MDCT) and of invasive interventions (thoracostomy tube placement). This was a retrospective case series involving 368 consecutive unstable adult patients (273 men and 95 women; average age, 25 years; range, 16-68 years) admitted to our hospital's emergency department between January 2011 and December 2012 for major trauma (Injury Severity Score ≥ 15). We evaluated the accuracy of thoracic ultrasound in the detection of pneumothorax compared with the results of MDCT and invasive interventions (thoracostomy tube placement). Institutional review board approval was obtained prior to commencement of this study. Among the 736 lung fields included in the study, 87 pneumothoraces were detected with thoracic CT scans (23.6%). e-FAST detected 67/87 and missed 20 pneumothoraces (17 mild, 3 moderate). The diagnostic performance of ultrasound was: sensitivity 77% (74% in 2011 and 80% in 2012), specificity 99.8%, positive predictive value 98.5%, negative predictive value 97%, accuracy 97.2% (67 true positive; 668 true negative; 1 false positive; 20 false negative); 17 missed mild pneumothoraces were not immediately life-threatening (thickness less than 5 mm). Thoracic ultrasound (e-FAST) is a rapid and accurate first-line, bedside diagnostic modality for the diagnosis of pneumothorax in unstable patients with major chest trauma during the primary survey in the emergency room.
Clarkson, Wesley A; Restrepo, Carlos Santiago; Bauch, Terry D; Rubal, Bernard J
2009-01-01
This study examines the effects of intravenous infusion of adenosine and sublingual nitroglycerin on coronary angiograms obtained by current-generation multidetector computed tomography. We assessed coronary vasodilation at baseline and after intravenous adenosine (140 µg/kg/min) or sublingual nitroglycerin spray (800 µg) in 7 female swine (weight, 40.9 ± 1.4 kg) by using electrocardiogram-gated coronary angiography with a 64-detector scanner (rotation time, 400 ms; 120kV; 400 mA) and intravenous contrast (300 mg/mL iohexol, 4.5 mL/s, 2 mL/kg). Cross-sectional areas of segments in the left anterior descending, circumflex, and right coronary arteries were evaluated in oblique orthogonal views. Images were acquired at an average heart rate of 73 ± 11 beats per minute. Changes in aortic pressure were not significant with nitroglycerin but decreased (approximately 10%) with adenosine. Of the 76 segments analyzed (baseline range, 2 to 39 mm2), 1 distal segment could not be assessed after adenosine. Segment cross-sectional area increased by 11.3% with nitroglycerin but decreased by 9.6% during adenosine infusion. The results of the present study are consistent with the practice of using sublingual nitroglycerin to enhance visualization of epicardial vessels and suggest that intravenous adenosine may hinder coronary artery visualization. This study is the first repeated-measures electrocardiogram-gated CT evaluation to use the same imaging technology to assess changes in coronary cross-sectional area before and after treatment with a vasodilator. The nitroglycerin-associated changes in our swine model were modest in comparison with previously reported human studies. PMID:20034433
Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro
2018-01-01
We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.
Gooley, Robert P; Cameron, James D; Soon, Jennifer; Loi, Duncan; Chitale, Gauri; Syeda, Rifath; Meredith, Ian T
2015-09-01
Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. The mean age was 59±12 years. The basal plane was eccentric (EI=0.22±0.06) while the left ventricular outflow tract was more eccentric (EI=0.32±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical reporting and for future research studies by using a standardised measurement technique. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan
2009-04-01
Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.
Chaosuwannakit, N; Makarawate, P
2018-01-01
Primary evaluation of patients with pulmonary atresia with ventricular septal defect (PA-VSD) traditionally relies upon echocardiography and conventional cardiac angiography (CCA). Cardiac angiography is considered the gold standard for delineation of anatomy in children with PA-VSD. Data comparing CCA and dual-source multidetector-row computed tomography angiography (MDCT) in PA-VSD patients is limited. The objective of this study was to test the hypothesis that MDCT is equivalent to CCA for anatomic delineation in these patients. Twenty-eight patients with PA-VSD underwent CCA and MDCT in close proximity to each other without interval therapy. A retrospective review of these 28 patients was performed. All MDCT data of pulmonary artery morphology, major aortopulmonary collateral arteries (MAPCAs) and type of blood supply (dual vs. single supply) were evaluated by blinded experts and results were compared with CCA. Twenty-eight patients had adequate size right and left pulmonary arteries (21 confluent and 7 non-confluent). Seven patients had complete absence of native pulmonary artery and 3 patients had stenosis of distal branches of pulmonary arteries; all had MAPCAs from descending thoracic aorta and/or subclavian arteries. Sensitivity, specificity, positive and negative predictive value of MDCT for detecting confluent of pulmonary arteries, absence of native pulmonary artery and stenosis of pulmonary arteries were all 100%. Moreover, accuracy of detecting MAPCAs was excellent. These results suggest that MDCT and CCA are equivalent in their ability to delineate pulmonary artery anatomy and MAPCAs. Dual source MDCT provides high diagnostic accuracy in evaluation of pulmonary blood supply in patients with PA-VSD and allows precise characterisation of the condition of pulmonary arteries and MAPCAs which is of paramount importance in managing patients with PA-VSD. (Folia Morphol 2018; 77, 1: 116-122).
Direk, Filiz; Uysal, Ismihan Ilknur; Kivrak, Ali Sami; Fazliogullari, Zeliha; Unver Dogan, Nadire; Karabulut, Ahmet Kagan
2018-03-01
The mental foramen and lingual vascular canals are related to vessels and nerves in the mandibular body. The aim of the present study was to determine the number and location of these structures and to make measurements of them. The archived Multidetector Computed Tomography images of 100 adult (15- to 70-year-old) patients were evaluated retrospectively. The diameters of the mental foramens and their distances from the front, back, upper and lower reference points were measured. The distribution of mental foramens with respect to the teeth was also researched. The presence of lingual vascular canals, and the number of median and lateral canals was determined, and the length of the median lingual vascular canals measured. All measurement parameters were analyzed by gender, side and age group. Eleven patients demonstrated a total of 15 accessory mental foramen. Median lingual vascular canals were observed in 100% of cases, with lateral lingual vascular canals determined in 32%. Significant differences were observed in the results of different gender groups (P < 0.05); in contrast, no significant difference was observed related with age or side. Accessory mental foramen was determined mostly in males, and unilaterally on the right side; also, the distances of mental foramen, except the distance from the back border of the mandible (P < 0.05), were found to be higher, bilaterally, in males. Variation of mental foramen, as well as the presence, position and size of lingual vascular canals can be clearly investigated by multidetector computed tomography. A preoperative knowledge of the positions of neurovascular and bone structures is very important for preventing complications that may occur during or after operations.
Liszewski, Mark C; Sahni, V Anik; Shyn, Paul B; Friedman, Sonia; Hornick, Jason L; Erturk, Sukru M; Mortele, Koenraad J
2012-01-01
To describe the multidetector-row computed tomography enterographic (MD-CTE) features of the ileal-anal pouch after ileal pouch anal anastomosis (IPAA) surgery and correlate them with pouch endoscopy and histopathologic findings. All MD-CTE examinations performed on patients who underwent IPAA from July 1, 2005 to December 1, 2010 (n = 35; 16 [45.7%] men; mean age, 37.7 years; age range, 22-72 years) were retrospectively evaluated in consensus by 2 radiologists. All studies were evaluated for the presence of multiple imaging features. Two radiographic scores were then calculated: a total radiographic score and a radiographic active inflammation score. In patients who underwent MD-CTE, pouch endoscopy, and biopsy within 30 days (n = 13), both scores were correlated with findings on pouch endoscopy and histopathology. Of the 35 patients, 33 (94%) had at least one MD-CTE finding of active or chronic pouch inflammation and 27 patients (77%) had at least one MD-CTE finding of active pouch inflammation. Of the 13 patients who underwent endoscopy and biopsy, the total radiographic score demonstrated a strong positive correlation with endoscopic score (r = 0.81; P = 0.001) and a moderate positive correlation with histopathologic score (r = 0.56; P = 0.047). The radiographic active inflammation score demonstrated a strong positive correlation with endoscopic score (r = 0.83; P = 0.0004), but only a weak nonsignificant positive correlation with histopathologic score (r = 0.492, P = 0.087). In patients who had IPAA surgery, findings on MD-CTE correlate positively with findings on pouch endoscopy and histopathology and are sensitive measures for pouch inflammation with high positive predictive value. Thus, MD-CTE can be a useful noninvasive test in the early evaluation of symptomatic patients.
Gaudio, Carlo; Mirabelli, Francesca; Pelliccia, Francesco; Francone, Marco; Tanzilli, Gaetano; Di Michele, Sara; Leonetti, Stefania; De Vincentis, Giuseppe; Carbone, Iacopo; Mangieri, Enrico; Catalano, Carlo; Passariello, Roberto
2009-07-10
The 64-slice multidetector-row computed tomography (MDCT) is an accurate noninvasive technique for assessing the degree of luminal narrowing in coronary arteries of patients with chronic ischemic disease. Aim of this study was to determine the value of MDCT in comparison to invasive coronary angiography (ICA) for detecting the presence and extent of coronary atherosclerotic plaques in a population of asymptomatic, hypertensive patients considered to be at high risk for cardiovascular events. We studied 67 asymptomatic, hypertensive patients at high-risk (Euro Score >5%). All patients had negative or nondiagnostic findings at exercise stress testing and therefore underwent both MDCT and ICA. In the per-patient analysis, MDCT correctly identified 16/17 (94%) patients with significant coronary artery disease involving at least 1 vessel and 48/50 (96%) normal subjects. In the per-segment analysis, MDCT correctly detected 21/22 (95%) coronary segments with a stenosis >or=50% and 856/868 (98%) normal segments, with a high negative predictivity of normal scans (100%). There was a good concordance between MDCT and ICA, with a high Pearson correlation coefficient between the coronary narrowings with the two techniques (r=0.84, p<0.01). Mean coronary calcium score was higher for the 17 patients with significant coronary artery disease on ICA than in the 50 patients without (422+/-223 HU vs 72+/-21 HU p<0.001). The ROC curves identified 160 as the best calcium volumetric score cut-off value able to identify >or=1 significant coronary stenosis with sensitivity 88% and specificity 85%. MDCT is an excellent noninvasive technique for early identification of significant coronary stenoses in high risk asymptomatic hypertensive patients and might provide unique information for the screening of this broad population.
2013-01-01
Introduction Peptic ulcer disease is still the major cause of gastrointestinal perforation despite major improvements in both diagnostic and therapeutic strategies. While the diagnosis of a perforated ulcer is straightforward in typical cases, its clinical onset may be subtle because of comorbidities and/or concurrent therapies. Case presentation We report the case of a 53-year-old Caucasian man with a history of chronic myeloid leukemia on maintenance therapy (100mg/day) with imatinib who was found to have a subphrenic abscess resulting from a perforated duodenal ulcer that had been clinically overlooked. Our patient was febrile (38.5°C) with abdominal tenderness and hypoactive bowel sounds. On the abdominal plain X-ray films, a right subphrenic abscess could be seen. On contrast-enhanced multi-detector computed tomography, a huge air-fluid collection extending from the subphrenic to the subhepatic anterior space was observed. After oral administration of 500cm3 of 3 percent diluted diatrizoate meglumine, an extraluminal leakage of the water-soluble iodinated contrast media could then be appreciated as a result of a perforated duodenal ulcer. During surgery, the abscess was drained and extensive adhesiolysis had to be performed to expose the duodenal bulb where the ulcer was first identified by methylene blue administration and then sutured. Conclusions While subphrenic abscesses are well known complications of perforated gastric or duodenal ulcers, they have nowadays become rare thanks to advances in both diagnostic and therapeutic strategies for peptic ulcer disease. However, when peptic ulcer disease is not clinically suspected, the contribution of imaging may be substantial. PMID:24215711
Yamada, Yoshitake; Jinzaki, Masahiro; Hashimoto, Masahiro; Shiomi, Eisuke; Abe, Takayuki; Kuribayashi, Sachio; Ogawa, Kenji
2013-08-01
To compare the diagnostic performance of tomosynthesis with that of chest radiography for the detection of pulmonary emphysema, using multidetector computed tomography (MDCT) as reference. Forty-eight patients with and 63 without pulmonary emphysema underwent chest MDCT, tomosynthesis and radiography on the same day. Two blinded radiologists independently evaluated the tomosynthesis images and radiographs for the presence of pulmonary emphysema. Axial and coronal MDCT images served as the reference standard and the percentage lung volume with attenuation values of -950 HU or lower (LAA-950) was evaluated to determine the extent of emphysema. Receiver-operating characteristic (ROC) analysis and generalised estimating equations model were used. ROC analysis revealed significantly better performance (P < 0.0001) of tomosynthesis than radiography for the detection of pulmonary emphysema. The average sensitivity, specificity, positive predictive value and negative predictive value of tomosynthesis were 0.875, 0.968, 0.955 and 0.910, respectively, whereas the values for radiography were 0.479, 0.913, 0.815 and 0.697, respectively. For both tomosynthesis and radiography, the sensitivity increased with increasing LAA-950. The diagnostic performance of tomosynthesis was significantly superior to that of radiography for the detection of pulmonary emphysema. In both tomosynthesis and radiography, the sensitivity was affected by the LAA-950. • Tomosynthesis showed significantly better diagnostic performance for pulmonary emphysema than radiography. • Interobserver agreement for tomosynthesis was significantly higher than that for radiography. • Sensitivity increased with increasing LAA -950 in both tomosynthesis and radiography. • Tomosynthesis imparts a similar radiation dose to two projection chest radiography. • Radiation dose and cost of tomosynthesis are lower than those of MDCT.
Chow, Benjamin J W; Freeman, Michael R; Bowen, James M; Levin, Leslie; Hopkins, Robert B; Provost, Yves; Tarride, Jean-Eric; Dennie, Carole; Cohen, Eric A; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan R; Paul, Narinder; Parker, John D; O'Reilly, Daria J; Xie, Feng; Goeree, Ron
2011-06-13
Computed tomographic coronary angiography (CTCA) has gained clinical acceptance for the detection of obstructive coronary artery disease. Although single-center studies have demonstrated excellent accuracy, multicenter studies have yielded variable results. The true diagnostic accuracy of CTCA in the "real world" remains uncertain. We conducted a field evaluation comparing multidetector CTCA with invasive CA (ICA) to understand CTCA's diagnostic accuracy in a real-world setting. A multicenter cohort study of patients awaiting ICA was conducted between September 2006 and June 2009. All patients had either a low or an intermediate pretest probability for coronary artery disease and underwent CTCA and ICA within 10 days. The results of CTCA and ICA were interpreted visually by local expert observers who were blinded to all clinical data and imaging results. Using a patient-based analysis (diameter stenosis ≥50%) of 169 patients, the sensitivity, specificity, positive predictive value, and negative predictive value were 81.3% (95% confidence interval [CI], 71.0%-89.1%), 93.3% (95% CI, 85.9%-97.5%), 91.6% (95% CI, 82.5%-96.8%), and 84.7% (95% CI, 76.0%-91.2%), respectively; the area under receiver operating characteristic curve was 0.873. The diagnostic accuracy varied across centers (P < .001), with a sensitivity, specificity, positive predictive value, and negative predictive value ranging from 50.0% to 93.2%, 92.0% to 100%, 84.6% to 100%, and 42.9% to 94.7%, respectively. Compared with ICA, CTCA appears to have good accuracy; however, there was variability in diagnostic accuracy across centers. Factors affecting institutional variability need to be better understood before CTCA is universally adopted. Additional real-world evaluations are needed to fully understand the impact of CTCA on clinical care. clinicaltrials.gov Identifier: NCT00371891.
Jeon, Sun Kyung; Choi, Young Hun; Cheon, Jung-Eun; Kim, Woo Sun; Cho, Yeon Jin; Ha, Ji Young; Lee, Seung Hyun; Hyun, Hyejin; Kim, In-One
2018-04-01
The 320-row multidetector computed tomography (CT) scanner has multiple scan modes, including volumetric modes. To compare the image quality and radiation dose of 320-row CT in three acquisition modes - helical, one-shot volume, and wide-volume scan - at pediatric brain imaging. Fifty-seven children underwent unenhanced brain CT using one of three scan modes (helical scan, n=21; one-shot volume scan, n=17; wide-volume scan, n=19). For qualitative analysis, two reviewers evaluated overall image quality and image noise using a 5-point grading system. For quantitative analysis, signal-to-noise ratio, image noise and posterior fossa artifact index were calculated. To measure the radiation dose, adjusted CT dose index per unit volume (CTDI adj ) and dose length product (DLP) were compared. Qualitatively, the wide-volume scan showed significantly less image noise than the helical scan (P=0.009), and less streak artifact than the one-shot volume scan (P=0.001). The helical mode showed significantly lower signal-to-noise ratio, with a higher image noise level compared with the one-shot volume and wide-volume modes (all P<0.05). The CTDI adj and DLP were significantly lower in the one-shot volume and wide-volume modes compared with those in the helical scan mode (all P<0.05). For pediatric unenhanced brain CT, both the wide-volume and one-shot volume scans reduced radiation dose compared to the helical scan mode, while the wide-volume scan mode showed fewer streak artifacts in the skull vertex and posterior fossa than the one-shot volume scan.
Lee, Jeong-Min; Kim, Myeong-Jin; Phongkitkarun, Sith; Sobhonslidsuk, Abhasnee; Holtorf, Anke-Peggy; Rinde, Harald; Bergmann, Karsten
2016-08-01
The effectiveness of treatment decisions and economic outcomes of using gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging (Gd-EOB-DTPA-MRI) were compared with extracellular contrast media-enhanced MRI (ECCM-MRI) and multi-detector computed tomography (MDCT) as initial procedures in patients with suspected hepatocellular carcinoma (HCC) in South Korea and Thailand. A decision-tree model simulated the clinical pathway for patients with suspected HCC from the first imaging procedure to a confirmed treatment decision. Input data (probabilities and resource consumptions) were estimated and validated by clinical experts. Costs for diagnostic alternatives and related treatment options were derived from published sources, taking into account both payer's and hospital's perspectives. All experts from Korea and Thailand agreed that Gd-EOB-DTPA-MRI yields the highest diagnostic certainty and minimizes the need for additional confirmatory diagnostic procedures in HCC. In Korea, from the payer's perspective, total cost was USD $3087/patient to reach a confirmed treatment decision using Gd-EOB-DTPA-MRI (vs $3205/patient for MDCT and $3403/patient for ECCM-MRI). From the hospital's perspective, Gd-EOB-DTPA-MRI incurred the lowest cost ($2289/patient vs $2320/patient and $2528/patient, respectively). In Thailand, Gd-EOB-DTPA-MRI was the least costly alternative for the payer ($702/patient vs $931/patient for MDCT and $873/patient for ECCM-MRI). From the hospital's perspective, costs were $1106/patient, $1178/patient, and $1087/patient for Gd-EOB-DTPA-MRI, MDCT, and ECCM-MRI, respectively. Gd-EOB-DTPA-MRI as an initial imaging procedure in patients with suspected HCC provides better diagnostic certainty and relevant statutory health insurance cost savings in Thailand and Korea, compared with ECCM-MRI and MDCT.
Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya
2015-06-01
The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi
2010-12-20
A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.
Xu, Qun; Wang, Xianchao; Xu, Chao
2017-06-01
Multiplication with traditional electronic computers is faced with a low calculating accuracy and a long computation time delay. To overcome these problems, the modified signed digit (MSD) multiplication routine is established based on the MSD system and the carry-free adder. Also, its parallel algorithm and optimization techniques are studied in detail. With the help of a ternary optical computer's characteristics, the structured data processor is designed especially for the multiplication routine. Several ternary optical operators are constructed to perform M transformations and summations in parallel, which has accelerated the iterative process of multiplication. In particular, the routine allocates data bits of the ternary optical processor based on digits of multiplication input, so the accuracy of the calculation results can always satisfy the users. Finally, the routine is verified by simulation experiments, and the results are in full compliance with the expectations. Compared with an electronic computer, the MSD multiplication routine is not only good at dealing with large-value data and high-precision arithmetic, but also maintains lower power consumption and fewer calculating delays.
Imaging in rectal cancer with emphasis on local staging with MRI
Arya, Supreeta; Das, Deepak; Engineer, Reena; Saklani, Avanish
2015-01-01
Imaging in rectal cancer has a vital role in staging disease, and in selecting and optimizing treatment planning. High-resolution MRI (HR-MRI) is the recommended method of first choice for local staging of rectal cancer for both primary staging and for restaging after preoperative chemoradiation (CT-RT). HR-MRI helps decide between upfront surgery and preoperative CT-RT. It provides high accuracy for prediction of circumferential resection margin at surgery, T category, and nodal status in that order. MRI also helps assess resectability after preoperative CT-RT and decide between sphincter saving or more radical surgery. Accurate technique is crucial for obtaining high-resolution images in the appropriate planes for correct staging. The phased array external coil has replaced the endorectal coil that is no longer recommended. Non-fat suppressed 2D T2-weighted (T2W) sequences in orthogonal planes to the tumor are sufficient for primary staging. Contrast-enhanced MRI is considered inappropriate for both primary staging and restaging. Diffusion-weighted sequence may be of value in restaging. Multidetector CT cannot replace MRI in local staging, but has an important role for evaluating distant metastases. Positron emission tomography-computed tomography (PET/CT) has a limited role in the initial staging of rectal cancer and is reserved for cases with resectable metastatic disease before contemplating surgery. This article briefly reviews the comprehensive role of imaging in rectal cancer, describes the role of MRI in local staging in detail, discusses the optimal MRI technique, and provides a synoptic report for both primary staging and restaging after CT-RT in routine practice. PMID:25969638
SU-F-207-03: Dosimetric Effect of the Position of Arms in Torso CT Scan with Tube Current Modulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, H; Rensselaer Polytechnic Institute, Troy, NY; Gao, Y
Purpose: To evaluate the patient organ dose differences between the arms-raised and arms-lowered postures in Torso multidetector computed tomography (MDCT) scan protocols with tube current modulation (TCM). Methods: Patient CT organ doses were simulated using the Monte Carlo method with human phantoms and a validated CT scanner model. A set of adult human phantoms with arms raised and arms lowered postures were developed using advanced BREP-based mesh surface geometries. Organ doses from routine Torso scan protocols such as chest, abdomen-pelvis, and CAP scans were simulated. The organ doses differences caused by two different posutres were investigated when tube current modulationmore » (TCM) were applied during the CT scan. Results: With TCM applied, organ doses of all the listed organs of arms-lowered posture phantom are larger than those of arms raised phantom. The dose difference for most of the organs or tissues are larger than 50%, and the skin doses difference for abdomen-pelvis scan even reaches 112.03%. This is due to the fact that the tube current for patient with arms-lowered is much higher than for the arms raised posture. Conclusion: Considering CT scan with TCM, which is commonly applied clinically, patients who could not raise their arms will receive higher radiation dose than the arms raised patient, with dose differences for some tissues such as the skin being larger than 100%. This is due to the additional tube current necessary to penetrate the arms while maintaining consistent image quality. National Nature Science Foundation of China(No.11475047)« less
Oe, Hiroki; Watanabe, Nobuhisa; Miyoshi, Toru; Osawa, Kazuhiro; Akagi, Teiji; Kanazawa, Susumu; Ito, Hiroshi
2018-06-18
Management of adult congenital heart disease (ACHD) patients requires understanding of its complex morphology and functional features. An innovative imaging technique has been developed to display a virtual multi-planar reconstruction obtained from contrast-enhanced multidetector-computed tomography (MDCT) corresponding to the same cross-sectional image from transthoracic echocardiography (TTE). The aim of this study is to assess the usefulness of this imaging technology in ACHD patients. This study consisted of 46 consecutive patients (30 women; mean age, 52±18 years old) with ACHD who had undergone contrast MDCT. All patients underwent TTE within a week of MDCT. An experienced sonographer who did not know the results of MDCT conducted a diagnosis using TTE and, then, using the new imaging technology. We studied whether this imaging technology provided additional or unexpected findings or makes more accurate diagnosis. In this imaging technology, MDCT cross-section provides higher-resolution image to the deep compared to corresponding TTE image. Depending on the MDCT section which can be arbitrarily set under the echo guide, we can diagnose unexpected or incremental lesions or more accurately assess the severity of the lesion in 27 patients (59%) compared to TTE study alone. This imaging technology was useful in the following situations: CONCLUSIONS: This integrated imaging technology provides incremental role over TTE in complex anatomy, and allows functional information in ACHD patients. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
2012-01-01
Background Rapid access chest pain clinics have facilitated the early diagnosis and treatment of patients with coronary heart disease and angina. Despite this important service provision, coronary heart disease continues to be under-diagnosed and many patients are left untreated and at risk. Recent advances in imaging technology have now led to the widespread use of noninvasive computed tomography, which can be used to measure coronary artery calcium scores and perform coronary angiography in one examination. However, this technology has not been robustly evaluated in its application to the clinic. Methods/design The SCOT-HEART study is an open parallel group prospective multicentre randomized controlled trial of 4,138 patients attending the rapid access chest pain clinic for evaluation of suspected cardiac chest pain. Following clinical consultation, participants will be approached and randomized 1:1 to receive standard care or standard care plus ≥64-multidetector computed tomography coronary angiography and coronary calcium score. Randomization will be conducted using a web-based system to ensure allocation concealment and will incorporate minimization. The primary endpoint of the study will be the proportion of patients diagnosed with angina pectoris secondary to coronary heart disease at 6 weeks. Secondary endpoints will include the assessment of subsequent symptoms, diagnosis, investigation and treatment. In addition, long-term health outcomes, safety endpoints, such as radiation dose, and health economic endpoints will be assessed. Assuming a clinic rate of 27.0% for the diagnosis of angina pectoris due to coronary heart disease, we will need to recruit 2,069 patients per group to detect an absolute increase of 4.0% in the rate of diagnosis at 80% power and a two-sided P value of 0.05. The SCOT-HEART study is currently recruiting participants and expects to report in 2014. Discussion This is the first study to look at the implementation of computed tomography in the patient care pathway that is outcome focused. This study will have major implications for the management of patients with cardiovascular disease. Trial registration ClinicalTrials.gov Identifier: NCT01149590 PMID:23036114
Radiologic evaluation of acute chest pain--suspected myocardial ischemia.
Stanford, William
2007-08-15
The American College of Radiology has developed appropriateness criteria for a number of clinical conditions and procedures. Criteria are available on imaging tests used in the evaluation of acute chest pain--suspected myocardial ischemia. Imaging tests for a suspected cardiac etiology include transthoracic echocardiography, transesophageal echocardiography, radionuclide perfusion imaging, radionuclide ventriculography, radionuclide infarct avid imaging, and positron emission tomography. If the cardiac ischemic work-up is negative or indeterminate, applicable tests include chest radiography; conventional, multidetector, and electron beam computed tomography; and magnetic resonance imaging. A summary of the criteria, with the advantages and limitations of each test, is presented in this article.
McQuiston, Andrew D; Crawford, Callie; Schoepf, U Joseph; Varga-Szemes, Akos; Canstein, Christian; Renker, Matthias; De Cecco, Carlo N; Baumann, Stefan; Naylor, Gavin J P
2017-01-01
AIM To apply dual-source multidetector computed tomography (DSCT) scanning technology in conjunction with computationally assisted segmentation in order to explore and document skeletal variation that has occurred over the course of evolution. METHODS We examined 4 divergent species of elasmobranchs with high-resolution 3rd generation DSCT. The formalin prepared species examined were: Aptychotrema vincentiana, Mitsukurina owstoni, Negaprion brevirostris and Dactylobatus armatus. RESULTS All three structures of the hyoid arch (hyomandibular, ceratohyal, and basihyal) were clearly visible whereas in the two batoids, the hyomandibular was the prominent feature, the ceratohyal was not visible and the basihyal was more reduced and closer to the gill arches. The general shape of the puboischiadic bar, or pelvic girdle, illustrated a closer relationship between the two sharks and the two batoids than between the two groups. CONCLUSION In exquisite detail, DSCT imaging revealed important morphological variations in various common structures in the four elasmobranch specimens studied, providing insights into their evolutionary diversification. PMID:28529682
Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi
2013-01-01
Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.
Crew/computer communications study. Volume 2: Appendixes
NASA Technical Reports Server (NTRS)
Johannes, J. D.
1974-01-01
The software routines developed during the crew/computer communications study are described to provide the user with an understanding of each routine, any restrictions in use, the required input data, and expected results after executing the routines. The combination of routines to generate a crew/computer communications application is also explained. The programmable keyboard and display used by the program is described, and an experiment scenario is provided to illustrate the relationship between the program frames when they are grouped into activity phases. Program descriptions and a user's guide are also presented. For Vol. 1, see N74-18843.
Schwaiger, Benedikt J; Kopperdahl, David L; Nardo, Lorenzo; Facchetti, Luca; Gersing, Alexandra S; Neumann, Jan; Lee, Kwang J; Keaveny, Tony M; Link, Thomas M
2017-08-01
Bone fracture risk assessed ancillary to positron emission tomography with computed tomography co-registration (PET/CT) could provide substantial clinical value to oncology patients with elevated fracture risk without introducing additional radiation dose. The purpose of our study was to investigate the feasibility of obtaining valid measurements of bone mineral density (BMD) and finite element analysis-derived bone strength of the hip and spine using PET/CT examinations of prostate cancer patients by comparing against values obtained using routine multidetector-row computed tomography (MDCT) scans-as validated in previous studies-as a reference standard. Men with prostate cancer (n=82, 71.6±8.3 years) underwent Fluorine-18 NaF PET/CT and routine MDCT within three months. Femoral neck and total hip areal BMD, vertebral trabecular BMD and femur and vertebral strength based on finite element analysis were assessed in 63 paired PET/CT and MDCT examinations using phantomless calibration and Biomechanical-CT analysis. Men with osteoporosis or fragile bone strength identified at either the hip or spine (vertebral trabecular BMD ≤80mg/cm 3 , femoral neck or total hip T-score ≤-2.5, vertebral strength ≤6500N and femoral strength ≤3500N, respectively) were considered to be at high risk of fracture. PET/CT- versus MDCT-based BMD and strength measurements were compared using paired t-tests, linear regression and by generating Bland-Altman plots. Agreement in fracture-risk classification was assessed in a contingency table. All measurements from PET/CT versus MDCT were strongly correlated (R 2 =0.93-0.97; P<0.0001 for all). Mean differences for total hip areal BMD (0.001g/cm 2 , 1.1%), femoral strength (-60N, 1.3%), vertebral trabecular BMD (2mg/cm 3 , 2.6%) and vertebral strength (150N; 1.7%) measurements were not statistically significant (P>0.05 for all), whereas the mean difference in femoral neck areal BMD measurements was small but significant (-0.018g/cm 2 ; -2.5%; P=0.007). The agreement between PET/CT and MDCT for fracture-risk classification was 97% (0.89 kappa for repeatability). Ancillary analyses of BMD, bone strength, and fracture risk agreed well between PET/CT and MDCT, suggesting that PET/CT can be used opportunistically to comprehensively assess bone integrity. In subjects with high fracture risk such as cancer patients this may serve as an additional clinical tool to guide therapy planning and prevention of fractures. Copyright © 2017 Elsevier Inc. All rights reserved.
Idriz, Sanjin; Patel, Jaymin H; Ameli Renani, Seyed; Allan, Rosemary; Vlahos, Ioannis
2015-01-01
The use of computed tomography (CT) in clinical practice has been increasing rapidly, with the number of CT examinations performed in adults and children rising by 10% per year in England. Because the radiology community strives to reduce the radiation dose associated with pediatric examinations, external factors, including guidelines for pediatric head injury, are raising expectations for use of cranial CT in the pediatric population. Thus, radiologists are increasingly likely to encounter pediatric head CT examinations in daily practice. The variable appearance of cranial sutures at different ages can be confusing for inexperienced readers of radiologic images. The evolution of multidetector CT with thin-section acquisition increases the clarity of some of these sutures, which may be misinterpreted as fractures. Familiarity with the normal anatomy of the pediatric skull, how it changes with age, and normal variants can assist in translating the increased resolution of multidetector CT into more accurate detection of fractures and confident determination of normality, thereby reducing prolonged hospitalization of children with normal developmental structures that have been misinterpreted as fractures. More important, the potential morbidity and mortality related to false-negative interpretation of fractures as normal sutures may be avoided. The authors describe the normal anatomy of all standard pediatric sutures, common variants, and sutural mimics, thereby providing an accurate and safe framework for CT evaluation of skull trauma in pediatric patients. (©)RSNA, 2015.
Ogura, I; Kaneda, T; Sasaki, Y; Buch, K; Sakai, O
2015-06-01
Temporal bone fracture after mandibular trauma is thought to be rare, and its prevalence has not been reported in the literature. The purpose of this study was to investigate the prevalence of temporal bone fractures in patients with mandibular fractures and the relationship between temporal bone fractures and the mandibular fracture location using multidetector-row computed tomography (MDCT). A prospective study was performed in 201 patients with mandibular fractures who underwent 64-MDCT scans. The mandibular fracture locations were classified as median, paramedian, angle, and condylar types. Statistical analysis for the relationship between prevalence of temporal bone fractures and mandibular fracture locations was performed using χ(2) test with Fisher's exact test. A P-value < 0.05 was considered statistically significant. The percentage of cases with temporal bone fracture was 3.0 % of all patients with mandibular fractures and 19.0 % of those with multiple mandibular fractures of paramedian and condylar type. There was a significant relationship between the incidence of temporal bone fracture and the paramedian- and condylar-type mandibular fracture (P = 0.001). Multiple mandibular fractures of paramedian and condylar type may be a stronger indicator for temporal bone fractures. This study suggests that patients with mandibular fracture, especially the paramedian and condylar type, should be examined for coexisting temporal bone fracture using MDCT.
Artioli, Diana; Tagliabue, Marianna; Aseni, Paolo; Sironi, Sandro; Vanzulli, Angelo
2010-11-01
To evaluate the performance of magnetic resonance (MR) and multidetector computed tomography (MDCT) in the assessment of living donor's vascular and biliary anatomy, having surgical findings as reference standard. Thirty-two living liver donors underwent MR cholangiography (1.5-T; standard cholangiography pulse sequences and delayed acquisitions after administration of biliary contrast agent) for biliary anatomy evaluation. MDCT (16-row multidetector scanner, multiphase protocol, 3mm slice thickness) was also performed in all cases for the assessment of vascular anatomy before transplantation. Hepatic veins (<4mm in diameter) were not considered. MR and MDCT images interpretation was performed by two reviewers by consensus, based on source axial images, multiplanar reformats, and three-dimensional (3D) postprocessing images. Surgical intraoperative findings were used as standard of reference. At surgery, 17 biliary anomalies, 3 portal anomalies, 32 venous and 8 arterial variants were found in the 32 patients. MR correctly identified 15/17 biliary anomalies, with a sensitivity of 88% and a specificity of 93%. MDCT correctly identified 8/8 arterial, 3/3 portal and 29/32 venous variants, with a sensitivity of 100% and 91%, respectively, and a specificity of 100%. MR and MDCT proved to be efficient in evaluating living liver donor's biliary and vascular anatomy. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Antunes, Sofia; Esposito, Antonio; Palmisano, Anna; Colantoni, Caterina; Cerutti, Sergio; Rizzo, Giovanna
2016-05-01
Extraction of the cardiac surfaces of interest from multi-detector computed tomographic (MDCT) data is a pre-requisite step for cardiac analysis, as well as for image guidance procedures. Most of the existing methods need manual corrections, which is time-consuming. We present a fully automatic segmentation technique for the extraction of the right ventricle, left ventricular endocardium and epicardium from MDCT images. The method consists in a 3D level set surface evolution approach coupled to a new stopping function based on a multiscale directional second derivative Gaussian filter, which is able to stop propagation precisely on the real boundary of the structures of interest. We validated the segmentation method on 18 MDCT volumes from healthy and pathologic subjects using manual segmentation performed by a team of expert radiologists as gold standard. Segmentation errors were assessed for each structure resulting in a surface-to-surface mean error below 0.5 mm and a percentage of surface distance with errors less than 1 mm above 80%. Moreover, in comparison to other segmentation approaches, already proposed in previous work, our method presented an improved accuracy (with surface distance errors less than 1 mm increased of 8-20% for all structures). The obtained results suggest that our approach is accurate and effective for the segmentation of ventricular cavities and myocardium from MDCT images.
NASA Astrophysics Data System (ADS)
Bose, Sukanta; Dayanga, Thilina; Ghosh, Shaon; Talukder, Dipongkar
2011-07-01
We describe a hierarchical data analysis pipeline for coherently searching for gravitational-wave signals from non-spinning compact binary coalescences (CBCs) in the data of multiple earth-based detectors. This search assumes no prior information on the sky position of the source or the time of occurrence of its transient signals and, hence, is termed 'blind'. The pipeline computes the coherent network search statistic that is optimal in stationary, Gaussian noise. More importantly, it allows for the computation of a suite of alternative multi-detector coherent search statistics and signal-based discriminators that can improve the performance of CBC searches in real data, which can be both non-stationary and non-Gaussian. Also, unlike the coincident multi-detector search statistics that have been employed so far, the coherent statistics are different in the sense that they check for the consistency of the signal amplitudes and phases in the different detectors with their different orientations and with the signal arrival times in them. Since the computation of coherent statistics entails searching in the sky, it is more expensive than that of the coincident statistics that do not require it. To reduce computational costs, the first stage of the hierarchical pipeline constructs coincidences of triggers from the multiple interferometers, by requiring their proximity in time and component masses. The second stage follows up on these coincident triggers by computing the coherent statistics. Here, we compare the performances of this hierarchical pipeline with and without the second (or coherent) stage in Gaussian noise. Although introducing hierarchy can be expected to cause some degradation in the detection efficiency compared to that of a single-stage coherent pipeline, nevertheless it improves the computational speed of the search considerably. The two main results of this work are as follows: (1) the performance of the hierarchical coherent pipeline on Gaussian data is shown to be better than the pipeline with just the coincident stage; (2) the three-site network of LIGO detectors, in Hanford and Livingston (USA), and Virgo detector in Cascina (Italy) cannot resolve the polarization of waves arriving from certain parts of the sky. This can cause the three-site coherent statistic at those sky positions to become singular. Regularized versions of the statistic can avoid that problem, but can be expected to be sub-optimal. The aforementioned improvement in the pipeline's performance due to the coherent stage is in spite of this handicap.
76 FR 4435 - Privacy Act of 1974; Report of Modified or Altered System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-25
... entry, computer systems analysis and computer programming services. The contractors promptly return data.... Proposed Routine Use Disclosures of Data in the System This System of Records contains information such as... compatible use of data is known as a ``routine use''. The routine uses proposed for this System are...
Computer routine adds plotting capabilities to existing programs
NASA Technical Reports Server (NTRS)
Harris, J. C.; Linnekin, J. S.
1966-01-01
PLOTAN, a generalized plot analysis routine written for the IBM 7094 computer, minimizes the difficulties in adding plot capabilities to large existing programs. PLOTAN is used in conjunction with a binary tape writing routine and has the ability to plot any variable on the intermediate binary tape as a function of any other.
Modular thermal analyzer routine, volume 1
NASA Technical Reports Server (NTRS)
Oren, J. A.; Phillips, M. A.; Williams, D. R.
1972-01-01
The Modular Thermal Analyzer Routine (MOTAR) is a general thermal analysis routine with strong capabilities for performing thermal analysis of systems containing flowing fluids, fluid system controls (valves, heat exchangers, etc.), life support systems, and thermal radiation situations. Its modular organization permits the analysis of a very wide range of thermal problems for simple problems containing a few conduction nodes to those containing complicated flow and radiation analysis with each problem type being analyzed with peak computational efficiency and maximum ease of use. The organization and programming methods applied to MOTAR achieved a high degree of computer utilization efficiency in terms of computer execution time and storage space required for a given problem. The computer time required to perform a given problem on MOTAR is approximately 40 to 50 percent that required for the currently existing widely used routines. The computer storage requirement for MOTAR is approximately 25 percent more than the most commonly used routines for the most simple problems but the data storage techniques for the more complicated options should save a considerable amount of space.
NASA Technical Reports Server (NTRS)
Wrenn, Gregory A.
2005-01-01
This report describes a database routine called DB90 which is intended for use with scientific and engineering computer programs. The software is written in the Fortran 90/95 programming language standard with file input and output routines written in the C programming language. These routines should be completely portable to any computing platform and operating system that has Fortran 90/95 and C compilers. DB90 allows a program to supply relation names and up to 5 integer key values to uniquely identify each record of each relation. This permits the user to select records or retrieve data in any desired order.
Haj-Mirzaian, Arya; Thawait, Gaurav K; Tanaka, Miho J; Demehri, Shadpour
2017-06-01
Patellofemoral instability (PI) is defined as single or multiple episodes of patellar dislocation. Imaging modalities are useful for characterization of patellar malalignment, maltracking, underlying morphologic abnormalities, and stabilizing soft-tissue injuries. Using these findings, orthopedic surgeons can decide when to operate, determine the best operation, and measure degree of correction postoperatively in PI patients. Also, these methods assist with PI diagnosis in some suspicious cases. Magnetic resonance imaging is the preferred method especially in the setting of acute dislocations. Multidetector computed tomography allows a more accurate assessment for malalignment such as patellar tilt and lateral subluxation and secondary osteoarthritis. Dynamic magnetic resonance imaging and 4-dimensional computed tomography have been introduced for better kinematic assessment of the patellofemoral maltracking during extension-flexion motions. In this review article, we will discuss the currently available evidence regarding both the conventional and the novel imaging modalities that can be used for diagnosis and characterization of PI.
The role of mobile computed tomography in mass fatality incidents.
Rutty, Guy N; Robinson, Claire E; BouHaidar, Ralph; Jeffery, Amanda J; Morgan, Bruno
2007-11-01
Mobile multi-detector computed tomography (MDCT) scanners are potentially available to temporary mortuaries and can be operational within 20 min of arrival. We describe, to our knowledge, the first use of mobile MDCT for a mass fatality incident. A mobile MDCT scanner attended the disaster mortuary after a five vehicle road traffic incident. Five out of six bodies were successfully imaged by MDCT in c. 15 min per body. Subsequent full radiological analysis took c. 1 h per case. The results were compared to the autopsy examinations. We discuss the advantages and disadvantages of imaging with mobile MDCT in relation to mass fatality work, illustrating the body pathway process, and its role in the identification of the pathology, personal effects, and health and safety hazards. We propose that the adoption of a single modality of mobile MDCT could replace the current use of multiple radiological sources within a mass fatality mortuary.
Konecki, Dariusz; Grabowska-Derlatka, Laretta; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, K; Zhao, W; Gomez-Cardona, D
Purpose: Automatic tube current modulation (TCM) has been widely used in modern multi-detector CT to reduce noise spatial nonuniformity and streaks to improve dose efficiency. With the advent of statistical iterative reconstruction (SIR), it is expected that the importance of TCM may diminish, since SIR incorporates statistical weighting factors to reduce the negative influence of photon-starved rays. The purpose of this work is to address the following questions: Does SIR offer the same benefits as TCM? If yes, are there still any clinical benefits to using TCM? Methods: An anthropomorphic CIRS chest phantom was scanned using a state-of-the-art clinical CTmore » system equipped with an SIR engine (Veo™, GE Healthcare). The phantom was first scanned with TCM using a routine protocol and a low-dose (LD) protocol. It was then scanned without TCM using the same protocols. For each acquisition, both FBP and Veo reconstructions were performed. All scans were repeated 50 times to generate an image ensemble from which noise spatial nonuniformity (NSN) and streak artifact levels were quantified. Monte-Carlo experiments were performed to estimate skin dose. Results: For FBP, noise streaks were reduced by 4% using TCM for both routine and LD scans. NSN values were actually slightly higher with TCM (0.25) than without TCM (0.24) for both routine and LD scans. In contrast, for Veo, noise streaks became negligible (<1%) with or without TCM for both routine and LD scans, and the NSN was reduced to 0.10 (low dose) or 0.08 (routine). The overall skin dose was 2% lower at the shoulders and more uniformly distributed across the skin without TCM. Conclusion: SIR without TCM offers superior reduction in noise nonuniformity and streaks relative to FBP with TCM. For some clinical applications in which skin dose may be a concern, SIR without TCM may be a better option. K. Li, W. Zhao, D. Gomez-Cardona: Nothing to disclose; G.-H. Chen: Research funded, General Electric Company Research funded, Siemens AG Research funded, Varian Medical Systems, Research funded, Hologic, Inc.« less
NASA Technical Reports Server (NTRS)
Knaub, D.; Yerazunis, S. W.
1978-01-01
Vertical wheel loads, wheel speeds, and torque relationships are considered in the design of a propulsion system capable of responding to steering, slope climbing, and irregular local terrains. The system developed is applied to the RPI Mars roving vehicle. The mechanical system required to implement the elevation laser scanning/multidetector principle was the design and construction of a mechanical system for implementing the elevation scanning/multidetector principle is also discussed.
Imaging of patent foramen ovale with 64-section multidetector CT.
Saremi, Farhood; Channual, Stephanie; Raney, Aidan; Gurudevan, Swaminatha V; Narula, Jagat; Fowler, Steven; Abolhoda, Amir; Milliken, Jeffrey C
2008-11-01
To investigate the feasibility of 64-section multidetector computed tomography (CT) by using CT angiography (a) to demonstrate anatomic detail of the interatrial septum pertinent to the patent foramen ovale (PFO), and (b) to visually detect left-to-right PFO shunts and compare these findings in patients who also underwent transesophageal echocardiography (TEE). In this institutional review board-approved HIPAA-compliant study, electrocardiographically gated coronary CT angiograms in 264 patients (159 men, 105 women; mean age, 60 years) were reviewed for PFO morphologic features. The length and diameter of the opening of the PFO tunnel, presence of atrial septal aneurysm (ASA), and PFO shunts were evaluated. A left-to-right shunt was assigned a grade according to length of contrast agent jet (grade 1,
Parallel spatial direct numerical simulations on the Intel iPSC/860 hypercube
NASA Technical Reports Server (NTRS)
Joslin, Ronald D.; Zubair, Mohammad
1993-01-01
The implementation and performance of a parallel spatial direct numerical simulation (PSDNS) approach on the Intel iPSC/860 hypercube is documented. The direct numerical simulation approach is used to compute spatially evolving disturbances associated with the laminar-to-turbulent transition in boundary-layer flows. The feasibility of using the PSDNS on the hypercube to perform transition studies is examined. The results indicate that the direct numerical simulation approach can effectively be parallelized on a distributed-memory parallel machine. By increasing the number of processors nearly ideal linear speedups are achieved with nonoptimized routines; slower than linear speedups are achieved with optimized (machine dependent library) routines. This slower than linear speedup results because the Fast Fourier Transform (FFT) routine dominates the computational cost and because the routine indicates less than ideal speedups. However with the machine-dependent routines the total computational cost decreases by a factor of 4 to 5 compared with standard FORTRAN routines. The computational cost increases linearly with spanwise wall-normal and streamwise grid refinements. The hypercube with 32 processors was estimated to require approximately twice the amount of Cray supercomputer single processor time to complete a comparable simulation; however it is estimated that a subgrid-scale model which reduces the required number of grid points and becomes a large-eddy simulation (PSLES) would reduce the computational cost and memory requirements by a factor of 10 over the PSDNS. This PSLES implementation would enable transition simulations on the hypercube at a reasonable computational cost.
Coy, Heidi; Young, Jonathan R; Douek, Michael L; Brown, Matthew S; Sayre, James; Raman, Steven S
2017-07-01
To evaluate the performance of a novel, quantitative computer-aided diagnostic (CAD) algorithm on four-phase multidetector computed tomography (MDCT) to detect peak lesion attenuation to enable differentiation of clear cell renal cell carcinoma (ccRCC) from chromophobe RCC (chRCC), papillary RCC (pRCC), oncocytoma, and fat-poor angiomyolipoma (fp-AML). We queried our clinical databases to obtain a cohort of histologically proven renal masses with preoperative MDCT with four phases [unenhanced (U), corticomedullary (CM), nephrographic (NP), and excretory (E)]. A whole lesion 3D contour was obtained in all four phases. The CAD algorithm determined a region of interest (ROI) of peak lesion attenuation within the 3D lesion contour. For comparison, a manual ROI was separately placed in the most enhancing portion of the lesion by visual inspection for a reference standard, and in uninvolved renal cortex. Relative lesion attenuation for both CAD and manual methods was obtained by normalizing the CAD peak lesion attenuation ROI (and the reference standard manually placed ROI) to uninvolved renal cortex with the formula [(peak lesion attenuation ROI - cortex ROI)/cortex ROI] × 100%. ROC analysis and area under the curve (AUC) were used to assess diagnostic performance. Bland-Altman analysis was used to compare peak ROI between CAD and manual method. The study cohort comprised 200 patients with 200 unique renal masses: 106 (53%) ccRCC, 32 (16%) oncocytomas, 18 (9%) chRCCs, 34 (17%) pRCCs, and 10 (5%) fp-AMLs. In the CM phase, CAD-derived ROI enabled characterization of ccRCC from chRCC, pRCC, oncocytoma, and fp-AML with AUCs of 0.850 (95% CI 0.732-0.968), 0.959 (95% CI 0.930-0.989), 0.792 (95% CI 0.716-0.869), and 0.825 (95% CI 0.703-0.948), respectively. On Bland-Altman analysis, there was excellent agreement of CAD and manual methods with mean differences between 14 and 26 HU in each phase. A novel, quantitative CAD algorithm enabled robust peak HU lesion detection and discrimination of ccRCC from other renal lesions with similar performance compared to the manual method.
Advantage of vein grafts for anomalous origin of a right coronary artery.
Kansaku, Rei; Saitoh, Hirofumi; Eguchi, Shoji; Maruyama, Yukio; Ohtsuka, Hideaki; Higuchi, Kotaro
2009-03-01
A 66-year-old man with anomalous origin of the right coronary artery suffered from chest pain. The results of coronary angiography and multidetector computer tomography indicated that the proximal right coronary artery was intermittently compressed, causing the ischemia. Coronary artery bypass grafting was regarded as a reliable treatment compared with percutaneous coronary intervention or other surgeries. Because of plentiful flow of the right coronary artery, we decided to use a vein graft to avoid competitive flow. Postoperative coronary angiography revealed intact flow in both the native coronary artery and the vein graft 1 year after the surgery. The myocardial ischemia seen on scintigraphy and the chest pain had disappeared.
Errors in imaging of traumatic injuries.
Scaglione, Mariano; Iaselli, Francesco; Sica, Giacomo; Feragalli, Beatrice; Nicola, Refky
2015-10-01
The advent of multi-detector computed tomography (MDCT) has drastically improved the outcomes of patients with multiple traumatic injuries. However, there are still diagnostic challenges to be considered. A missed or the delay of a diagnosis in trauma patients can sometimes be related to perception or other non-visual cues, while other errors are due to poor technique or poor image quality. In order to avoid any serious complications, it is important for the practicing radiologist to be cognizant of some of the most common types of errors. The objective of this article is to review the various types of errors in the evaluation of patients with multiple trauma injuries or polytrauma with MDCT.
Pediatric chest and abdominopelvic CT: organ dose estimation based on 42 patient models.
Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Paulson, Erik K; Frush, Donald P; Samei, Ehsan
2014-02-01
To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. The institutional review board approved this HIPAA-compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0-16 years; weight range, 2-80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDI(vol)). The relationships between CTDI(vol)-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. For organs within the image coverage, CTDI(vol)-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R(2) > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%-32%) mainly because of the effect of overranging. It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDI(vol). These CTDI(vol)-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013.
Mears, Molly; Coonrod, Dean V; Bay, R Curtis; Mills, Terry E; Watkins, Michelle C
2005-09-01
To compare endorsement rates obtained with audio computer-assisted self-interview versus routine prenatal history. A crosssectional study compared items captured with the routine history to those captured with a computer interview (computer screen displaying and computer audio reading questions, with responses entered by touch screen). The subjects were women (n=174) presenting to a public hospital clinic for prenatal care. The prevalence of positive responses using the computer interview was significantly greater (p < 0.01) than with the routine history for induced abortion (16.8% versus 4.0%), lifetime smoking (12.8% versus 5.2%), intimate partner violence (10.0% versus 2.4%), ectopic pregnancy (5.2% versus 1.1%) and family history of mental retardation (6.7% versus 0.6%). Significant differences were not found for history of spontaneous abortion, hypertension, epilepsy, thyroid disease, smoking during pregnancy, gynecologic surgery, abnormal Pap test, neural tube defect or cystic fibrosis family history. However, in all cases, prevalence was equal or greater with the computer interview. Women were more likely to report sensitive and high-risk behavior, such as smoking history, intimate partner violence and elective abortion, with the computer interview. The computer interview displayed equal or increased patient reporting of positive responses and may therefore be an accurate method of obtaining an initial history.
Space shuttle propulsion parameter estimation using optional estimation techniques
NASA Technical Reports Server (NTRS)
1983-01-01
A regression analyses on tabular aerodynamic data provided. A representative aerodynamic model for coefficient estimation. It also reduced the storage requirements for the "normal' model used to check out the estimation algorithms. The results of the regression analyses are presented. The computer routines for the filter portion of the estimation algorithm and the :"bringing-up' of the SRB predictive program on the computer was developed. For the filter program, approximately 54 routines were developed. The routines were highly subsegmented to facilitate overlaying program segments within the partitioned storage space on the computer.
User manual for two simple postscript output FORTRAN plotting routines
NASA Technical Reports Server (NTRS)
Nguyen, T. X.
1991-01-01
Graphics is one of the important tools in engineering analysis and design. However, plotting routines that generate output on high quality laser printers normally come in graphics packages, which tend to be expensive and system dependent. These factors become important for small computer systems or desktop computers, especially when only some form of a simple plotting routine is sufficient. With the Postscript language becoming popular, there are more and more Postscript laser printers now available. Simple, versatile, low cost plotting routines that can generate output on high quality laser printers are needed and standard FORTRAN language plotting routines using output in Postscript language seems logical. The purpose here is to explain two simple FORTRAN plotting routines that generate output in Postscript language.
Alasnag, Mirvat; Umakanthan, Branavan; Foster, Gary P
2008-07-01
Coronary arteriography (CA) is the standard method to image coronary lesions. Multidetector cardiac computerized tomography (MDCT) provides high-resolution images of coronary arteries, allowing a noninvasive alternative to determine lesion type. To date, no studies have assessed the ability of MDCT to categorize coronary lesion types. The objective of this study was to determine the accuracy of lesion type categorization by MDCT using CA as a reference standard. Patients who underwent both MDCT and CA within 2 months of each other were enrolled. MDCT and CA images were reviewed in a blinded fashion. Lesions were categorized according to the SCAI classification system (Types I-IV). The origin, proximal and middle segments of the major arteries were analyzed. Each segment comprised a data point for comparison. Analysis was performed using the Spearman Correlation Test. Four hundred eleven segments were studied, of which 110 had lesions. The lesion distribution was as follows: 35 left anterior descending (LAD), 29 circumflex (Cx), 31 right coronary artery (RCA), 2 ramus intermedius, 8 diagonal, 4 obtuse marginal and 2 left internal mammary arteries. Correlations between MDCT and CA were significant in all major vessels (LAD, Cx, RCA) (p < 0.001). The overall correlation coefficient was 0.67. Concordance was strong for lesion Types II-IV (97%) and poor for Type I (30%). High-risk coronary lesion types can be accurately categorized by MDCT. This ability may allow MDCT to play an important noninvasive role in the planning of coronary interventions.
Multidetector CT of Surgically Proven Blunt Bowel and Mesenteric Injury.
Bates, David D B; Wasserman, Michael; Malek, Anita; Gorantla, Varun; Anderson, Stephan W; Soto, Jorge A; LeBedis, Christina A
2017-01-01
Blunt traumatic injury is one of the leading causes of morbidity and mortality in the United States. Unintentional injury represents the leading cause of death in the United States for all persons between the ages of 1 and 44 years. In the setting of blunt abdominal trauma, the reported rate of occurrence of bowel and mesenteric injuries ranges from 1% to 5%. Despite the relatively low rate of blunt bowel and mesenteric injury in patients with abdominal and pelvic trauma, delays in diagnosis are associated with increased rates of sepsis, a prolonged course in the intensive care unit, and increased mortality. During the past 2 decades, as multidetector computed tomography (CT) has emerged as an essential tool in emergency radiology, several direct and indirect imaging features have been identified that are associated with blunt bowel and mesenteric injury. The imaging findings in cases of blunt bowel and mesenteric injury can be subtle and may be seen in the setting of multiple complex injuries, such as multiple solid-organ injuries and spinal fractures. Familiarity with the various imaging features of blunt bowel and mesenteric injury, as well as an understanding of their clinical importance with regard to the care of the patient, is essential to making a timely diagnosis. Once radiologists are familiar with the spectrum of findings of blunt bowel and mesenteric injury, they will be able to make timely diagnoses that will lead to improved patient outcomes. © RSNA, 2017.
Yahaba, Misuzu; Kawata, Naoko; Iesato, Ken; Matsuura, Yukiko; Sugiura, Toshihiko; Kasai, Hajime; Sakurai, Yoriko; Terada, Jiro; Sakao, Seiichiro; Tada, Yuji; Tanabe, Nobuhiro; Tatsumi, Koichiro
2014-06-01
Chronic obstructive pulmonary disease (COPD) is characterized by airflow limitation caused by emphysema and small airway narrowing. Quantitative evaluation of airway dimensions by multi-detector computed tomography (MDCT) has revealed a correlation between airway dimension and airflow limitation. However, the effect of emphysema on this correlation is unclear. The goal of this study was to determine whether emphysematous changes alter the relationships between airflow limitation and airway dimensions as measured by inspiratory and expiratory MDCT. Ninety-one subjects underwent inspiratory and expiratory MDCT. Images were evaluated for mean airway luminal area (Ai), wall area percentage (WA%) from the third to the fifth generation of three bronchi (B1, B5, B8) in the right lung, and low attenuation volume percent (LAV%). Correlations between each airway index and airflow limitation were determined for each patient and compared between patients with and without evidence of emphysema. In patients without emphysema, Ai and WA% from both the inspiratory and expiratory scans were significantly correlated with FEV1. No correlation was detected in patients with emphysema. In addition, emphysematous COPD patients with GOLD stage 1 or 2 disease had significantly lower changes in B8 Ai than non-emphysematous patients. A significant correlation exists between airway parameters and FEV1 in patients without emphysema. Emphysema may influence airway dimensions even in patients with mild to moderate COPD. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
He, Xiaoning; Holtorf, Anke-Peggy; Rinde, Harald; Xie, Shuangshuang; Shen, Wen; Hou, Jiancun; Li, Xuehua; Li, Ziping; Lai, Jiaming; Wang, Yuting; Zhang, Lin; Wang, Jian; Li, Xuesong; Ma, Kuansheng; Ye, Feng; Ouyang, Han; Zhao, Hong
2018-01-01
Limited data exists in China on the comparative cost of gadolinium ethoxybenzyl diethylenetriamine magnetic resonance imaging (Gd-EOB-DTPA-MRI) with other imaging techniques. This study compared the total cost of Gd-EOB-DTPA-MRI with multidetector computed tomography (MDCT) and extracellular contrast media–enhanced MRI (ECCM-MRI) as initial imaging procedures in patients with suspected hepatocellular carcinoma (HCC). We developed a decision-tree model on the basis of the Chinese clinical guidelines for HCC, which was validated by clinical experts from China. The model compared the diagnostic accuracy and costs of alternative initial imaging procedures. Compared with MDCT and ECCM-MRI, Gd-EOB-DTPA-MRI imaging was associated with higher rates of diagnostic accuracy, i.e. higher proportions of true positives (TP) and true negatives (TN) with lower false positives (FP). Total diagnosis and treatment cost per patient after the initial Gd-EOB-DTPA-MRI evaluation was similar to MDCT (¥30,360 vs. ¥30,803) and lower than that reported with ECCM-MRI (¥30,360 vs. ¥31,465). Lower treatment cost after initial Gd-EOB-DTPA-MRI was driven by reduced utilization of confirmatory diagnostic procedures and unnecessary treatments. The findings reported that Gd-EOB-DTPA-MRI offered higher diagnostic accuracy compared with MDCT and ECCM-MRI at a comparable cost, which indicates Gd-EOB-DTPA-MRI could be the preferred initial imaging procedure for the diagnosis of HCC in China. PMID:29324837
Kim, Sangroh; Yoshizumi, Terry; Toncheva, Greta; Yoo, Sua; Yin, Fang-Fang; Frush, Donald
2010-05-01
To address the lack of accurate dose estimation method in cone beam computed tomography (CBCT), we performed point dose metal oxide semiconductor field-effect transistor (MOSFET) measurements and Monte Carlo (MC) simulations. A Varian On-Board Imager (OBI) was employed to measure point doses in the polymethyl methacrylate (PMMA) CT phantoms with MOSFETs for standard and low dose modes. A MC model of the OBI x-ray tube was developed using BEAMnrc/EGSnrc MC system and validated by the half value layer, x-ray spectrum and lateral and depth dose profiles. We compared the weighted computed tomography dose index (CTDIw) between MOSFET measurements and MC simulations. The CTDIw was found to be 8.39 cGy for the head scan and 4.58 cGy for the body scan from the MOSFET measurements in standard dose mode, and 1.89 cGy for the head and 1.11 cGy for the body in low dose mode, respectively. The CTDIw from MC compared well to the MOSFET measurements within 5% differences. In conclusion, a MC model for Varian CBCT has been established and this approach may be easily extended from the CBCT geometry to multi-detector CT geometry.
Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman
2014-08-01
The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P < 0.05). No significant differences in artifact extent among different screw types and scanning positions were noted (P > 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.
Lee, Youn Joo; Lim, Yeon Soo; Lim, Hyun Wook; Yoo, Won Jong; Choi, Byung Gil; Kim, Bum Soo
2014-10-01
There are very few reports assessing in-stent restenosis (ISR) after vertebral artery ostium (VAO) stents using multidetector computed tomography (MDCT). To compare the diagnostic accuracy of computed tomography angiography (CTA) using 64-slice MDCT with digital subtraction angiography (DSA) for detection of significant ISR after VAO stenting. The study evaluated 57 VAO stents in 57 patients (39 men, 18 women; mean age 64 years [range, 48-90 years]). All stents were scanned with a 64-slice MDCT scanner. Three sets of images were reconstructed with three different convolution kernels. Two observers who were blinded to the results of DSA assessed the diagnostic accuracy of CTA for detecting significant ISR (≥50% diameter narrowing) of VAO stents in comparison with DSA as the reference standard. The sensitivity, specificity, positive and negative predictive values, and accuracy were calculated. Of the 57 stents, 46 (81%) were assessable using CTA, while 11 (19%) were not. No stents with diameters ≤2.75 mm were assessable. DSA revealed 13 cases of significant ISR in all stents. The respective sensitivity, specificity, positive and negative predictive values, and accuracy were 92%, 82%, 60%, 97%, and 84% for all stents. On excluding the 11 non-assessable stents, the respective values were 88%, 95%, 78%, 97%, and 93%. Of the 46 CTA assessable stents, eight significant ISRs were diagnosed on DSA. Seven of eight patients with significant ISR by DSA were diagnosed correctly with CTA. The area under the receiver-operating characteristic curve (AUC) was 0.87 for all stents and 0.91 for assessable stents, indicating good to excellent agreement between CTA and DSA for detecting significant ISR after VAO stenting. Sixty-four-slice MDCT is a promising non-invasive method of assessing stent patency and can exclude significant ISR with high diagnostic values after VAO stenting. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Bezzi, Mario; Bruni, Antonio
2011-02-15
We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound-color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findingsmore » and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.« less
Utsunomiya, Hiroto; Yamamoto, Hideya; Kunita, Eiji; Kitagawa, Toshiro; Ohashi, Norihiko; Oka, Toshiharu; Yamazato, Ryo; Horiguchi, Jun; Kihara, Yasuki
2010-11-01
We examined the association of aortic valve calcification (AVC) and mitral annular calcification (MAC) to coronary atherosclerosis using 64-multidetector computed tomography (MDCT). Valvular calcification is considered a manifestation of atherosclerosis. The impact of multiple heart valve calcium deposits on the distribution and characteristics of coronary plaque is unknown. We evaluated 322 patients referred for 64-MDCT, and assessed valvular calcification and the extent of calcified (CAP), mixed (MCAP), and noncalcified coronary atherosclerotic plaque (NCAP) in accordance with the 17-coronary segments model. We assessed the vulnerable characteristics of coronary plaque with positive remodeling, low-density plaque (CT density ≤38 Hounsfield units), and the presence of adjacent spotty calcification. In 49 patients with both AVC and MAC, the segment numbers of CAP and MCAP were larger than in those with a lack of valvular calcification and an isolated AVC (p<0.001 for both). Multivariate analyses revealed that a combined presence of AVC and MAC was independently associated with the presence (odds ratio [OR] 9.36, 95% confidence interval [95%CI] 1.55-56.53, p=0.015) and extent (β-estimate 1.86, p<0.001) of overall coronary plaque. When stratified by plaque composition, it was associated with the extent of CAP (β-estimate 1.77, p<0.001) and MCAP (β-estimate 1.04, p<0.001), but not with NCAP. Moreover, it was also related to the presence of coronary plaque with all three vulnerable characteristics (OR 4.87, 95%CI 1.85-12.83, p=0.001). The combined presence of AVC and MAC is highly associated with the presence, extent, and vulnerable characteristics of coronary plaque identified by 64-MDCT. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Pulmonary involvement in rheumatoid arthritis: multidetector computed tomography findings.
Yuksekkaya, Ruken; Celikyay, Fatih; Yilmaz, Ayse; Arslan, Sule; Inanir, Ahmet; Inonu, Handan; Deniz, Caglar
2013-12-01
Pulmonary involvement in rheumatoid arthritis (RA) is common and encompasses a large spectrum of disease with different treatment options and prognoses. Therefore, assessment of these patients with multidetector computed tomography (MDCT) is vital. To evaluate the MDCT pulmonary findings of patients with RA and to compare these findings with the clinical status. Chest MDCT scans of 85 patients with RA between 2006-2012 were assessed. One patient with a pulmonary infection was excluded from the study. MDCT findings and distribution of the CT findings were examined, and patients were classified according to the predominant CT pattern. The pulmonary function test (PFT) results and categories, demographic characteristics, and clinical status of some of the patients for whom the results were obtained were evaluated, and the CT findings, PFT results, demographic characteristics, and clinical status were compared. The study group consisted of 20 men (mean age, 58.1 years ± 13.1; range, 15-77 years) and 64 women (mean age, 55.3 years ± 11.5; range, 30-84 years). The most frequent findings were nodules (78.6%) and pleural thickening (48.8%). The most common CT patterns were follicular bronchiolitis (FB) in 28 (33.3%) patients and nodular disease (ND) in 12 (14.3%) others. There was no statistically significant difference between the CT findings and PFT results, and no statistically significant difference was noted in the CT findings between symptomatic and asymptomatic patients. In addition, there were some patients who exhibited no symptoms and/or had abnormal PFT results but had abnormal CT findings. Rheumatoid arthritis is associated with a high frequency of CT findings and CT patterns, with nodules and pleural thickening being the most common CT findings and FB and ND being the most common CT patterns. MDCT identification of patients with RA may be helpful in the evaluation of pulmonary disease, even in patients without symptoms and PFT abnormalities.
Aortic Arch Width and Cardiovascular Disease in Men and Women in the Community.
Chuang, Michael L; Gona, Philimon N; Qazi, Saadia; Musgrave, Rebecca M; Fox, Caroline S; Massaro, Joseph M; Hoffmann, Udo; O'Donnell, Christopher J
2018-06-16
We sought to determine whether increased aortic arch width (AAW) adds to standard Framingham risk factors and coronary artery calcium (CAC) for prediction of incident adverse cardiovascular disease (CVD) events in community-dwelling adults. A total of 3026 Framingham Heart Study Offspring and Third Generation cohort participants underwent noncontrast multidetector computed tomography from 2002 to 2005 to quantify CAC. We measured AAW as the distance between the centroids of the ascending and descending thoracic aorta, at the level of main pulmonary artery bifurcation or the right pulmonary artery. We determined sex, age group, and body size specific cut points for high (≥90th percentile) AAW from a healthy referent group (N=1471) and dichotomized AAW as high or not high across all study participants. Clinical covariates were obtained at Offspring cycle 7 (1998-2001) or Third Generation cycle 1 (2002-2005) examinations. The primary CVD outcome was a composite of myocardial infarction, coronary insufficiency, cerebrovascular accident, first hospitalization for heart failure, or CVD death. Cox proportional hazards models were used to estimate hazard ratio of high AAW on time-to-incident CVD after adjustment for Framingham risk factors and CAC. Net reclassification improvement was used to assess the effect of adding AAW to the baseline Framingham risk factor+CAC model. A total of 2826 participants (aged 51±11 years, 48% women) had complete covariates and were free of CVD at multidetector computed tomography. Over a median 8.9 years of follow-up, there were 135 incident CVD events. High AAW was independently predictive of CVD events (hazard ratio, 1.55; P =0.032) and appropriately reclassified participants at risk: net reclassification improvement, 0.31 (95% confidence interval, 0.15-0.48). AAW augments traditional CVD risk factors and CAC for prediction of incident adverse CVD events among community-dwelling adults. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Qi, Rui; Zhou, Xianping; Yu, Jianqun; Chen, Weixia; Li, Zhenlin; Zhang, Chunle
2012-08-01
The present paper is aimed to observe the lateral attachment of the renal fascia (RF) in vivo with multidetector computed tomography (MDCT) scanning, and to discuss its diagnostic value. 121 healthy adults were adopted into this experiment. All images were obtained with MDCT and double phase enhancement scanning. Then we observed the lateral attachment of RF. In addition, we mad a fresh body specimen as anatomical basis. The study found that above the renal hilar plane (RHP), the anterior renal fascia laterally fused with the peritoneum of the liver on the right and the peritoneum of the spleen on the left,and the posterior renal fascia fused with the subdiaphragmatic fascia. The lateral attachment of the RF at the RHP and the lower renal pole(LRP)is divided into three types. The RF in Type I is about 47.9% (58/121) at the left RHP, while about 33.9% (41/121) at the right RHP. At the LRP of the kidney is about 55.3% (67/121) on the left, and about 42.1% (51/121) on the right. The RF in Type I is about 38.8% (47/121) on the left side at the RHP, about 26.4% (32/121) on the right side. At the LRP, left side about 27.3% (33/121), right side about 13.3%(16/121). The RF in Type III at the RHP is 13.3% (16/121) on the left side, and on the right side is about 39.7% (48/121). At the LRP, it is about 17.4% (21/121) on the left side, and about 44.6% (54/121) on the right side. MDCT can display the lateral attachment of the RF better as well as the outside connection of the retroperitoneal space.
Saccular aortic aneurysm that resembled a mediastinal neoplasm
Nose, Naohiro; Kataoka, Hiroumi; Hamada, Masakatsu; Kosako, Yukio; Matsuno, Yasuji; Ishii, Takahiro
2012-01-01
INTRODUCTION Saccular aortic arch aneurysms in unusual sites may be misdiagnosed as a neoplasm. We present the case of a rare saccular aortic arch aneurysm between trachea and esophagus that resembled a mediastinal neoplasm in the preoperative findings. PRESENTATION OF CASE A 63-year-old male with an abnormal mediastinal shadow on chest X-ray was referred to the hospital. An axial plain computed tomogram of the chest revealed mediastinal soft tissue next to the right side of the aortic arch resembling a neoplasm originating from the gap between the trachea and the esophagus. The coronal view constructed by enhanced 64-row multi detector computed tomography revealed the soft tissue was an aneurysm arising from the inner side of the aortic arch. An aortic arch replacement was performed via a median sternotomy. DISCUSSION A thoracic aortic aneurysm sometimes behaves like a mediastinal neoplasm. The multiple cross-sectional image from multidetector computed tomography was useful for the correct diagnosis of such an aneurysm. CONCLUSION The possibility of an aneurysm should be considered whenever a mass in contact with the aortic wall is identified. PMID:22995656
Vesselness propagation: a fast interactive vessel segmentation method
NASA Astrophysics Data System (ADS)
Cai, Wenli; Dachille, Frank; Harris, Gordon J.; Yoshida, Hiroyuki
2006-03-01
With the rapid development of multi-detector computed tomography (MDCT), resulting in increasing temporal and spatial resolution of data sets, clinical use of computed tomographic angiography (CTA) is rapidly increasing. Analysis of vascular structures is much needed in CTA images; however, the basis of the analysis, vessel segmentation, can still be a challenging problem. In this paper, we present a fast interactive method for CTA vessel segmentation, called vesselness propagation. This method is a two-step procedure, with a pre-processing step and an interactive step. During the pre-processing step, a vesselness volume is computed by application of a CTA transfer function followed by a multi-scale Hessian filtering. At the interactive stage, the propagation is controlled interactively in terms of the priority of the vesselness. This method was used successfully in many CTA applications such as the carotid artery, coronary artery, and peripheral arteries. It takes less than one minute for a user to segment the entire vascular structure. Thus, the proposed method provides an effective way of obtaining an overview of vascular structures.
[Contribution of X-ray computed tomography in the evaluation of kidney performance].
Lemoine, Sandrine; Rognant, Nicolas; Collet-Benzaquen, Diane; Juillard, Laurent
2012-07-01
X-ray computer assisted tomography scanner is an imaging method based on the use of X-ray attenuation in tissue. This attenuation is proportional to the density of the tissue (without or after contrast media injection) in each pixel image of the image. Spiral scanner, the electron beam computed tomography (EBCT) scanner and multidetector computed tomography scanner allow renal anatomical measurements, such as cortical and medullary volume, but also the measurement of renal functional parameters, such as regional renal perfusion, renal blood flow and glomerular filtration rate. These functional parameters are extracted from the modeling of the kinetics of the contrast media concentration in the vascular space and the renal tissue, using two main mathematical models (the gamma variate model and the Patlak model). Renal functional imaging allows measuring quantitative parameters on each kidney separately, in a non-invasive manner, providing significant opportunities in nephrology, both for experimental and clinical studies. However, this method uses contrast media that may alter renal function, thus limiting its use in patients with chronic renal failure. Moreover, the increase irradiation delivered to the patient with multi detector computed tomography (MDCT) should be considered. Copyright © 2011 Association Société de néphrologie. Published by Elsevier SAS. All rights reserved.
Improvements in Routing for Packet-Switched Networks
1975-02-18
PROGRAM FOR COMPUTER SIMULATION . . 90 B.l Flow Diagram of Adaptive Routine 90 B.2 Progiam ARPSIM 93 B.3 Explanation of Variables...equa. 90 APPENDIX B ADAPTIVE ROUTING PROGRAM FOR COMPUTER SIMULA HON The computer simulation for adaptive routing was initially run on a DDP-24 small...TRANSMIT OVER AVAILABLE LINKS MESSAGES IN QUEUE COMPUTE Ni NUMBER OF ARRIVALS AT EACH NODE i AT TIME T Fig. Bla - Flow Diagram of Program Routine 92
Novel wearable and wireless ring-type pulse oximeter with multi-detectors.
Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh
2014-09-19
The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter.
Novel Wearable and Wireless Ring-Type Pulse Oximeter with Multi-Detectors
Huang, Cheng-Yang; Chan, Ming-Che; Chen, Chien-Yue; Lin, Bor-Shyh
2014-01-01
The pulse oximeter is a popular instrument to monitor the arterial oxygen saturation (SPO2). Although a fingertip-type pulse oximeter is the mainstream one on the market at present, it is still inconvenient for long-term monitoring, in particular, with respect to motion. Therefore, the development of a wearable pulse oximeter, such as a finger base-type pulse oximeter, can effectively solve the above issue. However, the tissue structure of the finger base is complex, and there is lack of detailed information on the effect of the light source and detector placement on measuring SPO2. In this study, the practicability of a ring-type pulse oximeter with a multi-detector was investigated by optical human tissue simulation. The optimal design of a ring-type pulse oximeter that can provide the best efficiency of measuring SPO2 was discussed. The efficiency of ring-type pulse oximeters with a single detector and a multi-detector was also discussed. Finally, a wearable and wireless ring-type pulse oximeter was also implemented to validate the simulation results and was compared with the commercial fingertip-type pulse oximeter. PMID:25244586
An Input Routine Using Arithmetic Statements for the IBM 704 Digital Computer
NASA Technical Reports Server (NTRS)
Turner, Don N.; Huff, Vearl N.
1961-01-01
An input routine has been designed for use with FORTRAN or SAP coded programs which are to be executed on an IBM 704 digital computer. All input to be processed by the routine is punched on IBM cards as declarative statements of the arithmetic type resembling the FORTRAN language. The routine is 850 words in length. It is capable of loading fixed- or floating-point numbers, octal numbers, and alphabetic words, and of performing simple arithmetic as indicated on input cards. Provisions have been made for rapid loading of arrays of numbers in consecutive memory locations.
Addai, Theodore; Kola, Monahar; Raqeem, Muhammad Wajih; Barsamyan, Sergey; Mirrakhimov, Aibek E.
2016-01-01
An 82-year-old female with history of hyperlipidemia and hypertension presented to the clinic with chief complaint of nonradiating chest tightness accompanied by exertional dyspnea. Cardiac catheterization showed the absence of left coronary system; the entire coronary system originated from the right aortic sinus as a common trunk which then gave off the right coronary artery and the left main coronary artery. Cardiac catheterization demonstrated also another rare coronary anomaly: dual left anterior descending artery. Patient underwent percutaneous coronary intervention and subsequent multidetector computed tomography angiography confirmed the above angiography findings. Patient was subsequently discharged home on double antiplatelet therapy with aspirin and clopidogrel and has been asymptomatic since then. PMID:27293909
Abchee, Antoine; Saade, Charbel; Al-Mohiy, Hussain; El-Merhi, Fadi
2014-01-01
Congenital vascular anomalies of the venous drainage in the chest affect both cardiac and non-cardiac structures. Collateral venous drainage from the left subclavian vein to the great cardiac vein is a rare venous drainage pattern. These anomalies present a diagnostic challenge. Multi-detector computed tomography (MDCT) is useful in the diagnosis and treatment planning of these clinically complex disorders. We present a case report of an 18-year-old Caucasian male who came to our institute for evaluation of venous drainage patterns to the heart. We describe the contrast technique of bilateral dual injection MDCT venography and the imaging features of the venous drainage patterns to the heart. PMID:25379351
Abchee, Antoine; Saade, Charbel; Al-Mohiy, Hussain; El-Merhi, Fadi
2014-01-01
Congenital vascular anomalies of the venous drainage in the chest affect both cardiac and non-cardiac structures. Collateral venous drainage from the left subclavian vein to the great cardiac vein is a rare venous drainage pattern. These anomalies present a diagnostic challenge. Multi-detector computed tomography (MDCT) is useful in the diagnosis and treatment planning of these clinically complex disorders. We present a case report of an 18-year-old Caucasian male who came to our institute for evaluation of venous drainage patterns to the heart. We describe the contrast technique of bilateral dual injection MDCT venography and the imaging features of the venous drainage patterns to the heart.
Imaging in chronic obstructive pulmonary disease.
Shaker, Saher B; Dirksen, Asger; Bach, Karen S; Mortensen, Jann
2007-06-01
Chronic obstructive pulmonary disease (COPD) is divided into pulmonary emphysema and chronic bronchitis (CB). Emphysema is defined patho-anatomically as "permanent enlargement of airspaces distal to the terminal bronchiole, accompanied by the destruction of their walls, and without obvious fibrosis" (1). These lesions are readily identified and quantitated using computed tomography (CT), whereas the accompanying hyperinflation is best detected on plain chest X-ray, especially in advanced disease. The diagnosis of CB is clinical and relies on the presence of productive cough for 3 months in 2 or more successive years. The pathological changes of mucosal inflammation and bronchial wall thickening have been more difficult to identify with available imaging techniques. However, recent studies using Multi-detector row CT (MDCT) reported more reproducible assessment of air wall thickening.
Estimation of regional lung expansion via 3D image registration
NASA Astrophysics Data System (ADS)
Pan, Yan; Kumar, Dinesh; Hoffman, Eric A.; Christensen, Gary E.; McLennan, Geoffrey; Song, Joo Hyun; Ross, Alan; Simon, Brett A.; Reinhardt, Joseph M.
2005-04-01
A method is described to estimate regional lung expansion and related biomechanical parameters using multiple CT images of the lungs, acquired at different inflation levels. In this study, the lungs of two sheep were imaged utilizing a multi-detector row CT at different lung inflations in the prone and supine positions. Using the lung surfaces and the airway branch points for guidance, a 3D inverse consistent image registration procedure was used to match different lung volumes at each orientation. The registration was validated using a set of implanted metal markers. After registration, the Jacobian of the deformation field was computed to express regional expansion or contraction. The regional lung expansion at different pressures and different orientations are compared.
Fuld, Matthew K.; Grout, Randall; Guo, Junfeng; Morgan, John H.; Hoffman, Eric A.
2013-01-01
Rationale and Objectives Multidetector-row Computed Tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics) and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breath-hold at a standardized volume. Materials and Methods A computer monitored turbine-based flow meter system was developed to control patient breath-holds and facilitate static imaging at fixed percentages of the vital capacity. Due to calibration challenges with gas density changes during multi-breath xenon-CT an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. Results The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was −9 ml (−169, 151); for TLC alone 6 ml (−164, 177); for FRC alone, −23 ml (−172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject non-compliance with verbal instruction and gas leaks around the mouthpiece. Conclusion We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon-CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multi-breath wash-in xenon-CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon-CT method for assessing regional lung function, while not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon-CT measures can be validated. PMID:22555001
Fuld, Matthew K; Grout, Randall W; Guo, Junfeng; Morgan, John H; Hoffman, Eric A
2012-08-01
Multidetector-row computed tomography (MDCT) has emerged as a tool for quantitative assessment of parenchymal destruction, air trapping (density metrics), and airway remodeling (metrics relating airway wall and lumen geometry) in chronic obstructive pulmonary disease (COPD) and asthma. Critical to the accuracy and interpretability of these MDCT-derived metrics is the assurance that the lungs are scanned during a breathhold at a standardized volume. A computer monitored turbine-based flow meter system was developed to control patient breathholds and facilitate static imaging at fixed percentages of the vital capacity. Because of calibration challenges with gas density changes during multibreath xenon CT, an alternative system was required. The design incorporated dual rolling seal pistons. Both systems were tested in a laboratory environment and human subject trials. The turbine-based system successfully controlled lung volumes in 32/37 subjects, having a linear relationship for CT measured air volume between repeated scans: for all scans, the mean and confidence interval of the differences (scan1-scan2) was -9 mL (-169, 151); for total lung capacity alone 6 mL (-164, 177); for functional residual capacity alone, -23 mL (-172, 126). The dual-piston system successfully controlled lung volume in 31/41 subjects. Study failures related largely to subject noncompliance with verbal instruction and gas leaks around the mouthpiece. We demonstrate the successful use of a turbine-based system for static lung volume control and demonstrate its inadequacies for dynamic xenon CT studies. Implementation of a dual-rolling seal spirometer has been shown to adequately control lung volume for multibreath wash-in xenon CT studies. These systems coupled with proper patient coaching provide the tools for the use of CT to quantitate regional lung structure and function. The wash-in xenon CT method for assessing regional lung function, although not necessarily practical for routine clinical studies, provides for a dynamic protocol against which newly emerging single breath, dual-energy xenon CT measures can be validated. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.
Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K
2016-05-01
The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Goh, Vicky; Halligan, Steve; Hugill, Jo-Ann; Gartner, Louise; Bartram, Clive I
2005-01-01
To determine the effect of acquisition time on quantitative colorectal cancer perfusion measurement. Dynamic contrast-enhanced computed tomography (CT) was performed prospectively in 10 patients with histologically proven colorectal cancer using 4-detector row CT (Lightspeed Plus; GE Healthcare Technologies, Waukesha, WI). Tumor blood flow, blood volume, mean transit time, and permeability were assessed for 3 acquisition times (45, 65, and 130 seconds). Mean values for all 4 perfusion parameters for each acquisition time were compared using the paired t test. Significant differences in permeability values were noted between acquisitions of 45 seconds and 65 and 130 seconds, respectively (P=0.02, P=0.007). There was no significant difference for values of blood volume, blood flow, and mean transit time between any of the acquisition times. Scan acquisitions of 45 seconds are too short for reliable permeability measurement in the abdomen. Longer acquisition times are required.
Computer-based route-definition system for peripheral bronchoscopy.
Graham, Michael W; Gibbs, Jason D; Higgins, William E
2012-04-01
Multi-detector computed tomography (MDCT) scanners produce high-resolution images of the chest. Given a patient's MDCT scan, a physician can use an image-guided intervention system to first plan and later perform bronchoscopy to diagnostic sites situated deep in the lung periphery. An accurate definition of complete routes through the airway tree leading to the diagnostic sites, however, is vital for avoiding navigation errors during image-guided bronchoscopy. We present a system for the robust definition of complete airway routes suitable for image-guided bronchoscopy. The system incorporates both automatic and semiautomatic MDCT analysis methods for this purpose. Using an intuitive graphical user interface, the user invokes automatic analysis on a patient's MDCT scan to produce a series of preliminary routes. Next, the user visually inspects each route and quickly corrects the observed route defects using the built-in semiautomatic methods. Application of the system to a human study for the planning and guidance of peripheral bronchoscopy demonstrates the efficacy of the system.
Gupta, Atul K; Alberico, Ronald A; Litwin, Alan; Kanter, Peter; Grossman, Zachary D
2002-01-01
To demonstrate that gadopentetate dimeglumine is potentially an alternative contrast medium for computed tomographic angiography (CTA). One 12.2-kg Beagle dog was studied as proof of principle; the cervical vessels of three adult human patients were imaged for presurgical planning of the neck. Gadopentetate dimeglumine, 0.5 mol/l (Berlex Laboratories, Wayne, NJ, U.S.A.), a LightSpeed QX/i CT (General Electric Medical Systems, Milwaukee, WI, U.S.A.), and an Ultra Sparc II (SUN Microsystems, Santa Clara, CA, U.S.A.) running Advantage Windows 3.1 (General Electric Medical Systems) were used. Sufficient enhancement for CTA of the thoracic aorta, cervical vessels, and abdominal vessels was produced in the experimental dog, and the cervical vessels were clearly defined in all three patients. In that subset of patients with contraindications to iodinated contrast medium and for whom magnetic resonance angiography is inappropriate, gadopentetate dimeglumine may be an alternative contrast medium for CTA.
Ekizoglu, Oguzhan; Inci, Ercan; Hocaoglu, Elif; Sayin, Ibrahim; Kayhan, Fatma Tulin; Can, Ismail Ozgur
2014-05-01
Gender determination is an important step in identification. For gender determination, anthropometric evaluation is one of the main forensic evaluations. In the present study, morphometric analysis of maxillary sinuses was performed to determine gender. For morphometric analysis, coronal and axial paranasal sinus computed tomography (CT) scan with 1-mm slice thickness was used. For this study, 140 subjects (70 women and 70 men) were enrolled (age ranged between 18 and 63). The size of each subject's maxillary sinuses was measured in anteroposterior, transverse, cephalocaudal, and volume directions. In each measurement, the size of the maxillary sinus is significantly small in female gender (P < 0.001). When discrimination analysis was performed, the accuracy rate was detected as 80% for women and 74.3% for men with an overall rate of 77.15%. With the use of 1-mm slice thickness CT, morphometric analysis of maxillary sinuses will be helpful for gender determination.
Konecki, Dariusz; Pacho, Ryszard; Rowiński, Olgierd
2017-01-01
Summary Background Endoscopic methods (gastroscopy and colonoscopy) are considered fundamental for the diagnosis of gastrointestinal bleeding. In recent years, multidetector computed tomography (MDCT) has also gained importance in diagnosing gastrointestinal bleeding, particularly in hemodynamically unstable patients and in cases with suspected lower gastrointestinal tract bleeding. CT can detect both the source and the cause of active gastrointestinal bleeding, thereby expediting treatment initiation. Material/Methods The study group consisted of 16 patients with clinical symptoms of gastrointestinal bleeding in whom features of active bleeding were observed on CT. In all patients, bleeding was verified by means of other methods such as endoscopic examinations, endovascular procedures, or surgery. Results The bleeding source was identified on CT in all 16 patients. In 14 cases (87.5%), bleeding was confirmed by other methods. Conclusions CT is an efficient, fast, and readily available tool for detecting the location of acute gastrointestinal bleeding. PMID:29662594
[The radiologist physician in major trauma evaluation].
Motta-Ramírez, Gaspar Alberto
2016-01-01
Trauma is the most common cause of death in young adults. A multidisciplinary trauma team consists of at least a surgical team, an anesthesiology team, radiologic team, and an emergency department team. Recognize the integration of multidisciplinary medical team in managing the trauma patient and which must include the radiologist physician responsible for the institutional approach to the systematization of the trauma patient regarding any radiological and imaging study with emphasis on the FAST (del inglés, Focused Assessment with Sonography in Trauma)/USTA, Whole body computed tomography. Ultrasound is a cross-sectional method available for use in patients with major trauma. Whole-body multidetector computed tomography became the imaging modality of choice in the late 1990s. In patients with major trauma, examination FAST often is the initial imaging examination, extended to extraabdominal regions. Patients who have multitrauma from blunt mechanisms often require multiple diagnostic examinations, including Computed Tomography imaging of the torso as well as abdominopelvic Computed Tomography angiography. Multiphasic Whole-body trauma imaging is feasible, helps detect clinically relevant vascular injuries, and results in diagnostic image quality in the majority of patients. Computed Tomography has gained importance in the early diagnostic phase of trauma care in the emergency room. With a single continuous acquisition, whole-body computed tomography angiography is able to demonstrate all potentially injured organs, as well as vascular and bone structures, from the circle of Willis to the symphysis pubis.
NASA Technical Reports Server (NTRS)
Wigton, Larry
1996-01-01
Improving the numerical linear algebra routines for use in new Navier-Stokes codes, specifically Tim Barth's unstructured grid code, with spin-offs to TRANAIR is reported. A fast distance calculation routine for Navier-Stokes codes using the new one-equation turbulence models is written. The primary focus of this work was devoted to improving matrix-iterative methods. New algorithms have been developed which activate the full potential of classical Cray-class computers as well as distributed-memory parallel computers.
Lin, Yuning; Chen, Ziqian; Yang, Xizhang; Zhong, Qun; Zhang, Hongwen; Yang, Li; Xu, Shangwen; Li, Hui
2013-12-01
The aim of this study is to evaluate the diagnostic performance of multidetector CT angiography (CTA) in depicting bronchial and non-bronchial systemic arteries in patients with haemoptysis and to assess whether this modality helps determine the feasibility of angiographic embolisation. Fifty-two patients with haemoptysis between January 2010 and July 2011 underwent both preoperative multidetector CTA and digital subtraction angiography (DSA) imaging. Diagnostic performance of CTA in depicting arteries causing haemoptysis was assessed on a per-patient and a per-artery basis. The feasibility of the endovascular treatment evaluated by CTA was analysed. Sensitivity, specificity, and positive and negative predictive values for those analyses were determined. Fifty patients were included in the artery-presence-number analysis. In the per-patient analysis, neither CTA (P = 0.25) nor DSA (P = 1.00) showed statistical difference in the detection of arteries causing haemoptysis. The sensitivity, specificity, and positive and negative predictive values were 94%, 100%, 100%, and 40%, respectively, for the presence of pathologic arteries evaluated by CTA, and 98%, 100%, 100%, and 67%, respectively, for DSA. On the per-artery basis, CTA correctly identified 97% (107/110). Fifty-two patients were included in the feasibility analysis. The performance of CTA in predicting the feasibility of angiographic embolisation was not statistically different from the treatment performed (P = 1.00). The sensitivity, specificity, and positive and negative predictive values were 96%, 80%, 98% and 67%, respectively, for CTA. Multidetector CTA is an accurate imaging method in depicting the presence and number of arteries causing haemoptysis. This modality is also useful for determining the feasibility of angiographic embolisation for haemoptysis. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.
Tacher, Vania; Duran, Rafael; Lin, MingDe; Sohn, Jae Ho; Sharma, Karun V.; Wang, Zhijun; Chapiro, Julius; Gacchina Johnson, Carmen; Bhagat, Nikhil; Dreher, Matthew R.; Schäfer, Dirk; Woods, David L.; Lewis, Andrew L.; Tang, Yiqing; Grass, Michael; Wood, Bradford J.
2016-01-01
Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70–150-μm radiopaque microspheres in saline (radiopaque microsphere group), 70–150-μm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70–150-μm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. © RSNA, 2015 PMID:26678453
Dewailly, Marion; Rémy-Jardin, Martine; Duhamel, Alain; Faivre, Jean-Baptiste; Pontana, François; Deken, Valérie; Bakai, Anne-Marie; Remy, Jacques
2010-01-01
To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT). Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD. The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality. The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.
Elucidating early CT after pancreatico-duodenectomy: a primer for radiologists.
Tonolini, Massimo; Ierardi, Anna Maria; Carrafiello, Gianpaolo
2018-04-13
Pancreatico-duodenectomy (PD) represents the standard surgical treatment for resectable malignancies of the pancreatic head, distal common bile duct, periampullary region and duodenum, and is also performed to manage selected benign tumours and refractory chronic pancreatitis. Despite improved surgical techniques and acceptable mortality, PD remains a technically demanding, high-risk operation burdened with high morbidity (complication rates 40-50% of patients). Multidetector computed tomography (CT) represents the mainstay modality to rapidly investigate the postoperative abdomen, and to provide a consistent basis for an appropriate choice between conservative, interventional or surgical treatment. However, radiologists require familiarity with the surgically altered anatomy, awareness of expected imaging appearances and possible complications to correctly interpret early post-PD CT studies. This paper provides an overview of surgical indications and techniques, discusses risk factors and clinical manifestations of the usual postsurgical complications, and suggests appropriate techniques and indications for early postoperative CT imaging. Afterwards, the usual, normal early post-PD CT findings are presented, including transient fluid, pneumobilia, delayed gastric emptying, identification of pancreatic gland remnant and of surgical anastomoses. Finally, several imaging examples review the most common and some unusual complications such as pancreatic fistula, bile leaks, abscesses, intraluminal and extraluminal haemorrhage, and acute pancreatitis. • Pancreatico-duodenectomy (PD) is a technically demanding surgery burdened with high morbidity (40-50%). • Multidetector CT is the mainstay technique to investigate suspected complications following PD. • Interpreting post-PD CT requires knowledge of surgically altered anatomy and expected findings. • CT showing collection at surgical site supports clinico-biological diagnosis of pancreatic fistula. • Other complications include biliary leaks, haemorrhage, abscesses and venous thrombosis.
Kikuchi, Yasuka; Oyama-Manabe, Noriko; Naya, Masanao; Manabe, Osamu; Tomiyama, Yuuki; Sasaki, Tsukasa; Katoh, Chietsugu; Kudo, Kohsuke; Tamaki, Nagara; Shirato, Hiroki
2014-07-01
This study introduces a method to calculate myocardium blood flow (MBF) and coronary flow reserve (CFR) using the relatively low-dose dynamic 320-row multi-detector computed tomography (MDCT), validates the method against (15)O-H₂O positron-emission tomography (PET) and assesses the CFRs of coronary artery disease (CAD) patients. Thirty-two subjects underwent both dynamic CT perfusion (CTP) and PET perfusion imaging at rest and during pharmacological stress. In 12 normal subjects (pilot group), the calculation method for MBF and CFR was established. In the other 13 normal subjects (validation group), MBF and CFR obtained by dynamic CTP and PET were compared. Finally, the CFRs obtained by dynamic CTP and PET were compared between the validation group and CAD patients (n = 7). Correlation between MBF of MDCT and PET was strong (r = 0.95, P < 0.0001). CFR showed good correlation between dynamic CTP and PET (r = 0.67, P = 0.0126). CFRCT in the CAD group (2.3 ± 0.8) was significantly lower than that in the validation group (5.2 ± 1.8) (P = 0.0011). We established a method for measuring MBF and CFR with the relatively low-dose dynamic MDCT. Lower CFR was well demonstrated in CAD patients by dynamic CTP. • MBF and CFR can be calculated using dynamic CTP with 320-row MDCT. • MBF and CFR showed good correlation between dynamic CTP and PET. • Lower CFR was well demonstrated in CAD patients by dynamic CTP.
Osteoporosis Imaging: State of the Art and Advanced Imaging
2012-01-01
Osteoporosis is becoming an increasingly important public health issue, and effective treatments to prevent fragility fractures are available. Osteoporosis imaging is of critical importance in identifying individuals at risk for fractures who would require pharmacotherapy to reduce fracture risk and also in monitoring response to treatment. Dual x-ray absorptiometry is currently the state-of-the-art technique to measure bone mineral density and to diagnose osteoporosis according to the World Health Organization guidelines. Motivated by a 2000 National Institutes of Health consensus conference, substantial research efforts have focused on assessing bone quality by using advanced imaging techniques. Among these techniques aimed at better characterizing fracture risk and treatment effects, high-resolution peripheral quantitative computed tomography (CT) currently plays a central role, and a large number of recent studies have used this technique to study trabecular and cortical bone architecture. Other techniques to analyze bone quality include multidetector CT, magnetic resonance imaging, and quantitative ultrasonography. In addition to quantitative imaging techniques measuring bone density and quality, imaging needs to be used to diagnose prevalent osteoporotic fractures, such as spine fractures on chest radiographs and sagittal multidetector CT reconstructions. Radiologists need to be sensitized to the fact that the presence of fragility fractures will alter patient care, and these fractures need to be described in the report. This review article covers state-of-the-art imaging techniques to measure bone mineral density, describes novel techniques to study bone quality, and focuses on how standard imaging techniques should be used to diagnose prevalent osteoporotic fractures. © RSNA, 2012 PMID:22438439
Sourwine, Mariaileen; Jeudy, Jean; Miller, Brian; Vunnam, Rama; Imanli, Hasan; Mesubi, Olurotimi; Etienne-Mesubi, Martine; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm
2017-10-01
A significant number of ventricular tachycardia circuits are located close to the epicardial surface and are amendable to epicardial ablation. Epicardial fat often interferes with substrate mapping and ablation, though little is known regarding the distribution of fat and its fluctuation with the cardiac cycle. We studied 40 patients who underwent a 64-slice multidetector computed tomography in order to describe patterns of epicardial fat distribution, variation during cardiac cycle, and clinical predictors of epicardial fat. Multiplanar reconstructions were analyzed during systole and diastole in six cross-sections. Epicardial fat thickness was measured across multiple wall segments in each view. Epicardial fat was found to be thicker in areas overlying coronary vasculature (7.8 ± 2.6 mm vs 3.5 ± 0.9 mm, P = 0.001), along with the right ventricular wall (3.9 ± 0.8 mm vs 2.6 ± 0.6 mm, P = 0.001) and the ventricular base (6.1 ± 1.7 mm vs 4.6 ± 1.6 mm, P < 0.01). Epicardial fat thickness increased 27% during systole as compared to diastole (4.9 ± 2.7 mm vs 6.2 ± 3.0 mm, P = 0.04). Variation with cardiac cycle was most evident along the right ventricular wall (3.9 ± 0.8 mm vs 5.0 ± 1.3 mm, P = 0.001) and nonvascular areas (P = 0.001), especially at the ventricular base (3.7 ± 1.1 mm vs 5.3 ± 1.5 mm, P = 0.001). In multivariate logistic regression, we found that age >50 years (P = 0.031) and coronary artery disease (P = 0.023) were statistically correlated with epicardial fat >5-mm thickness and body mass index > 33 (P = 0.052) nearly so. Baseline epicardial fat thickness >5 mm is common in areas typically targeted during epicardial ablation and further increases during the cardiac cycle. Simple clinical characteristics can identify patients with >5 mm epicardial fat in which preprocedural computed tomography imaging and three-dimensional fat map reconstruction may facilitate epicardial ablation. © 2017 Wiley Periodicals, Inc.
Broad ligament hernia successfully treated by laparoscopy: Case report and review of literature.
Matsunami, Masatoshi; Kusanagi, Hiroshi; Hayashi, Ken; Yamada, Shigetoshi; Kano, Nobuyasu
2014-11-01
We report a case of a 36-year-old woman with a history of caesarean section who presented with small bowel obstruction. Abdominal multi-detector CT showed discontinuity of the small bowel near the broad ligament on the left. We made a provisional diagnosis of an internal hernia through a defect in the broad ligament and performed laparoscopic exploration, which revealed a viable ileal loop incarcerated by the broad ligament. Multi-detector CT may be useful for diagnosing this type of defect preoperatively, whereby open surgery can be avoided. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.
Measurement of positron annihilation lifetimes for positron burst by multi-detector array
NASA Astrophysics Data System (ADS)
Wang, B. Y.; Kuang, P.; Liu, F. Y.; Han, Z. J.; Cao, X. Z.; Zhang, P.
2018-03-01
It is currently impossible to exploit the timing information in a gamma-ray pulse generated within nanoseconds when a high-intensity positron burst annihilation event occurs in a target using conventional single-detector methods. A state-of-the-art solution to the problem is proposed in this paper. In this approach, a multi-detector array composed of many independent detection cells mounted spherically around the target is designed to detect the time distribution of the annihilated gamma rays generated following, in particular, a positron burst emitting huge amounts of positrons in a short pulse duration, even less than a few nano- or picoseconds.
Routine operation of an Elliott 903 computer in a clinical chemistry laboratory
Whitby, L. G.; Simpson, D.
1973-01-01
Experience gained in the last four years concerning the capabilities and limitations of an 8K Elliott 903 (18-bit word) computer with magnetic tape backing store in the routine operation of a clinical chemistry laboratory is described. Designed as a total system, routine operation has latterly had to be confined to data acquisition and process control functions, due primarily to limitations imposed by the choice of hardware early in the project. In this final report of a partially successful experiment the opportunity is taken to review mistakes made, especially at the start of the project, to warn potential computer users of pitfalls to be avoided. PMID:4580240
Lee, L.Y.
1973-12-01
A readout system has been provided for reading out a radiation multidetector device with a reduced number of signal sensors. A radiation hodoscope, such as an array of scintillation counters, multiwire proportional counter array, or a set of multidetectors which do not receive signals simultaneously, is divided into equal numbered groups. A first group of signal terminals is connected to the equal numbered groups of detectors so that a signal from any one of the detectors of a group will be fed to one of the first group of terminals. A second group of signal terminals is connected to the detector groups so that a signal from a particular numbered detector of each of the detector groups is connected to one of the second group of terminals. Both groups of signal terminals are, in turn, coupled to signal sensors so that when a signal is simultaneously observed in one of the first group of terminals and one of the second group of tenniinals the specific detector detecting a radiation event is determined. The sensors are arranged in such a manner that a binary code is developed from their outputs which can be stored in a digital storage means according to the location of the event in the multidetector device. (Official Gazette)
Dual-energy computed tomography for the detection of focal liver lesions.
Lago, K N; Vallejos, J; Capuñay, C; Salas, E; Reynoso, E; Carpio, J B; Carrascosa, P M
To qualitatively and quantitatively explore the spectral study of focal liver lesions, comparing it with the usual polychromatic assessment with single-energy computed tomography. We prospectively studied 50 patients with at least one focal liver lesion who were referred for abdominal multidetector computed tomography with intravenous contrast material. The portal phase was acquired with dual energy sources. The density of the lesions and of the surrounding liver parenchyma was measured both in the baseline polychromatic acquisition and in the posterior monochromatic reconstructions at 40 keV, 70 keV, and 140 keV. Spectral curves were traced and the dual-energy indices and contrast-to-noise ratio were calculated. Lastly, the quality of the images and the detectability of the lesions were assessed qualitatively. Densitometric differences between the different types of lesions (avascular and vascularized) and the liver were greater at low energy levels (left side of the spectral curve) than in the polychromatic evaluation. In the subjective assessment, the 40keV energy level had the greatest lesion detectability. Monochromatic spectral study with dual-energy computed tomography provides better lesion detectability at 40keV compared to that provided by the ordinary polychromatic evaluation. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Burrowes, K S; Hunter, P J; Tawhai, M H
2005-01-01
We have developed an image-based computational model of blood flow within the human pulmonary circulation in order to investigate the distribution of flow under various conditions of posture and gravity. Geometric models of the lobar surfaces and largest arterial and venous vessels were derived from multi-detector row X-ray computed tomography. The remaining blood vessels were generated using a volume-filling branching algorithm. Equations representing conservation of mass and momentum are solved within the vascular geometry to calculate pressure, radius, and velocity distributions. Flow solutions are obtained within the model in the upright, inverted, prone, and supine postures and in the upright posture with and without gravity. Additional equations representing large deformation mechanics are used to calculate the change in lung geometry and pressure distributions within the lung in the various postures - creating a coupled, co-dependent model of mechanics and flow. The embedded vascular meshes deform in accordance with the lung geometry. Results illustrate a persistent flow gradient from the top to the bottom of the lung even in the absence of gravity and in all postures, indicating that vascular branching structure is largely responsible for the distribution of flow.
High Intensity Focused Ultrasound Ablation of Pancreatic Neuroendocrine Tumours: Report of Two Cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orgera, Gianluigi, E-mail: gianluigi.orgera@ieo.it; Krokidis, Miltiadis; Monfardini, Lorenzo
2011-04-15
We describe the use of ultrasound-guided high-intensity focused ultrasound (HIFU) for ablation of two pancreatic neuroendocrine tumours (NETs; insulinomas) in two inoperable young female patients. Both suffered from episodes of severe nightly hypoglycemia that was not efficiently controlled by medical treatment. After HIFU ablation, local disease control and symptom relief were achieved without postinterventional complications. The patients remained free of symptoms during 9-month follow-up. The lesions appeared to be decreased in volume, and there was decreased enhancing pattern in the multidetector computed tomography control (MDCT). HIFU is likely to be a valid alternative for symptoms control in patients with pancreaticmore » NETs. However, currently the procedure should be reserved for inoperable patients for whom symptoms cannot be controlled by medical therapy.« less
Bilateral subclavian origin of the bronchial arteries combined with absence of other origins.
Jie, Bing; Sun, Xi-Wen; Yu, Dong; Jiang, Sen
2014-08-01
There are numerous anatomical variations of the sites of origin of the bronchial arteries (BAs). A subclavian origin of a BA involves an aberrant artery that originates from the subclavian artery (SCA) or its branches. However, the aberrant artery usually originates directly from the SCA, and an SCA-origin BA arising from the branches of the SCA is rare. We herein present an extremely rare case of a right BA arising from the ipsilateral costocervical trunk, and a left BA arising from the ipsilateral thyrocervical trunk, in the absence of other origins of the BA. This anatomical variation was detected during pretherapeutic evaluation by multidetector-row computed tomography and confirmed by selective angiography. Recognition of these anatomic variations is important to surgical, diagnostic, and interventional radiologic procedures in the thorax.
Dose reduction in paediatric MDCT: general principles.
Paterson, A; Frush, D P
2007-06-01
The number of multi-detector array computed tomography (MDCT) examinations performed per annum continues to increase in both the adult and paediatric populations. Estimates from 2003 suggested that CT contributed 17% of a radiology department's workload, yet was responsible for up to 75% of the collective population dose from medical radiation. The effective doses for some CT examinations today overlap with those argued to have an increased risk of cancer. This is especially pertinent for paediatric CT, as children are more radiosensitive than adults (and girls more radiosensitive than boys). In addition, children have a longer life ahead of them, in which radiation induced cancers may become manifest. Radiologists must be aware of these facts and practise the ALARA (as low as is reasonably achievable) principle, when it comes to deciding CT protocols and parameters.
Trabecular bone class mapping across resolutions: translating methods from HR-pQCT to clinical CT
NASA Astrophysics Data System (ADS)
Valentinitsch, Alexander; Fischer, Lukas; Patsch, Janina M.; Bauer, Jan; Kainberger, Franz; Langs, Georg; DiFranco, Matthew
2015-03-01
Quantitative assessment of 3D bone microarchitecture in high-resolution peripheral quantitative computed tomography (HR-pQCT) has shown promise in fracture risk assessment and biomechanics, but is limited to the distal radius and tibia. Trabecular microarchitecture classes (TMACs), based on voxel-wise clustering texture and structure tensor features in HRpQCT, is extended in this paper to quantify trabecular bone classes in clinical multi-detector CT (MDCT) images. Our comparison of TMACs in 12 cadaver radii imaged using both HRpQCT and MDCT yields a mean Dice score of up to 0.717+/-0.40 and visually concordant bone quality maps. Further work to develop clinically viable bone quantitative imaging using HR-pQCT validation could have a significant impact on overall bone health assessment.
NASA Technical Reports Server (NTRS)
1974-01-01
This report presents the derivation, description, and operating instructions for a computer program (TEKVAL) which measures the economic value of advanced technology features applied to long range commercial passenger aircraft. The program consists of three modules; and airplane sizing routine, a direct operating cost routine, and an airline return-on-investment routine. These modules are linked such that they may be operated sequentially or individually, with one routine generating the input for the next or with the option of externally specifying the input for either of the economic routines. A very simple airplane sizing technique was previously developed, based on the Brequet range equation. For this program, that sizing technique has been greatly expanded and combined with the formerly separate DOC and ROI programs to produce TEKVAL.
1988-06-30
casting. 68 Figure 1-9: Line printer representation of roll solidification. 69 Figure I1-1: Test casting model. 76 Figure 11-2: Division of test casting...writing new casting analysis and design routines. The new routines would take advantage of advanced criteria for predicting casting soundness and cast...properties and technical advances in computer hardware and software. 11 2. CONCLUSIONS UPCAST, a comprehensive software package, has been developed for
Resequencing Skills and Concepts in Applied Calculus Using the Computer as a Tool.
ERIC Educational Resources Information Center
Heid, M. Kathleen
1988-01-01
During the first 12 weeks of an applied calculus course, two classes of college students studied calculus concepts using graphical and symbol-manipulation computer programs to perform routine manipulations. Three weeks were spent on skill development. Students showed better understanding of concepts and performed almost as well on routine skills.…
Right heart on multidetector CT
Gopalan, D
2011-01-01
Right ventricular function plays an integral role in the pathogenesis and outcome of many cardiovascular diseases. Imaging the right ventricle has long been a challenge because of its complex geometry. In recent years there has been a tremendous expansion in multidetector row CT (MDCT) and its cardiac applications. By judicious modification of contrast medium protocol, it is possible to achieve good opacification of the right-sided cardiac chambers, thereby paving the way for exploring the overshadowed right heart. This article will describe the key features of right heart anatomy, review MDCT acquisition techniques, elaborate the various morphological and functional information that can be obtained, and illustrate some important clinical conditions associated with an abnormal right heart. PMID:22723537
Larsen, V H; Waldau, T; Gravesen, H; Siggaard-Andersen, O
1996-01-01
To describe a clinical case where an extremely low erythrocyte 2,3-diphosphoglycerate concentration (2,3-DPG) was discovered by routine blood gas analysis supplemented by computer calculation of derived quantities. The finding of a low 2,3-DPG revealed a severe hypophosphatemia. Open uncontrolled study of a patient case. Intensive care observation during 41 days. A 44 year old woman with an abdominal abscess. Surgical drainage, antibiotics and parenteral nutrition. daily routine blood gas analyses with computer calculation of the hemoglobin oxygen affinity and estimation of the 2,3-DPG. An abrupt decline of 2,3-DPG was observed late in the course coincident with a pronounced hypophosphatemia. The fall in 2,3-DPG was verified by enzymatic analysis. 2,3-DPG may be estimated by computer calculation of routine blood gas data. A low 2,3-DPG which may be associated with hypophosphatemia causes an unfavorable increase in hemoglobin oxygen affinity which reduces the oxygen release to the tissues.
Colombi, Davide; Dinkel, Julien; Weinheimer, Oliver; Obermayer, Berenike; Buzan, Teodora; Nabers, Diana; Bauer, Claudia; Oltmanns, Ute; Palmowski, Karin; Herth, Felix; Kauczor, Hans Ulrich; Sverzellati, Nicola
2015-01-01
Objectives To describe changes over time in extent of idiopathic pulmonary fibrosis (IPF) at multidetector computed tomography (MDCT) assessed by semi-quantitative visual scores (VSs) and fully automatic histogram-based quantitative evaluation and to test the relationship between these two methods of quantification. Methods Forty IPF patients (median age: 70 y, interquartile: 62-75 years; M:F, 33:7) that underwent 2 MDCT at different time points with a median interval of 13 months (interquartile: 10-17 months) were retrospectively evaluated. In-house software YACTA quantified automatically lung density histogram (10th-90th percentile in 5th percentile steps). Longitudinal changes in VSs and in the percentiles of attenuation histogram were obtained in 20 untreated patients and 20 patients treated with pirfenidone. Pearson correlation analysis was used to test the relationship between VSs and selected percentiles. Results In follow-up MDCT, visual overall extent of parenchymal abnormalities (OE) increased in median by 5 %/year (interquartile: 0 %/y; +11 %/y). Substantial difference was found between treated and untreated patients in HU changes of the 40th and of the 80th percentiles of density histogram. Correlation analysis between VSs and selected percentiles showed higher correlation between the changes (Δ) in OE and Δ 40th percentile (r=0.69; p<0.001) as compared to Δ 80th percentile (r=0.58; p<0.001); closer correlation was found between Δ ground-glass extent and Δ 40th percentile (r=0.66, p<0.001) as compared to Δ 80th percentile (r=0.47, p=0.002), while the Δ reticulations correlated better with the Δ 80th percentile (r=0.56, p<0.001) in comparison to Δ 40th percentile (r=0.43, p=0.003). Conclusions There is a relevant and fully automatically measurable difference at MDCT in VSs and in histogram analysis at one year follow-up of IPF patients, whether treated or untreated: Δ 40th percentile might reflect the change in overall extent of lung abnormalities, notably of ground-glass pattern; furthermore Δ 80th percentile might reveal the course of reticular opacities. PMID:26110421
Kudo, Tomoaki; Kuratani, Toru; Shimamura, Kazuo; Sakamoto, Tomohiko; Kin, Keiwa; Masada, Kenta; Shijo, Takayuki; Torikai, Kei; Maeda, Koichi; Sawa, Yoshiki
2017-10-01
Type 1a endoleak is one of the most severe complications after thoracic endovascular aortic repair (TEVAR), because it carries the risk of aortic rupture. The association between bird-beak configuration and Type 1a endoleak remains unclear. The purpose of this study was to analyse the predictors of Type 1a endoleak following Zone 1 and Zone 2 TEVAR, with a particular focus on the effect of bird-beak configuration. From April 2008 to July 2015, 105 patients (mean age 68.6 years) who underwent Zone 1 and 2 landing TEVAR were enrolled, with a mean follow-up period of 4.3 years. The patients were categorized into 2 groups, according to the presence (Group B, n = 32) or the absence (Group N, n = 73) of bird-beak configuration on the first postoperative multidetector computed tomography. The Kaplan-Meier event-free rate curve showed that Type 1a endoleak and bird-beak progression occurred less frequently in Group N than in Group B. Five-year freedom from Type 1a endoleak rates were 79.7% and 100% for Groups B and N, respectively (P = 0.007). Multivariable logistic regression analysis showed that dissecting aortic aneurysm (odds ratio 3.72, 95% confidence interval 1.30-11.0; P = 0.014) and shorter radius of inner curvature (odds ratio 1.09, 95% confidence interval 0.85-0.99; P = 0.025) were significant risk factors for bird-beak configuration. Multivariable Cox proportional hazard regression showed that Z-type stent graft (hazard ratio 2.69, 95% confidence interval 1.11-6.51; P = 0.030) was a significant risk factor for bird-beak progression. Appropriate stent grafts need to be chosen carefully to prevent Type 1a endoleak and bird-beak configuration after landing Zone 1 and 2 TEVAR. Patients with bird-beak configuration on early postoperative multidetector computed tomography require closer follow-up to screen for Type 1a endoleak. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
2010-01-01
Introduction In recent years, several massive earthquakes have occurred across the globe. Multidetector computed tomography (MDCT) is reliable in detecting spinal injuries. The purpose of this study was to compare the features of spinal injuries resulting from the Sichuan earthquake with those of non-earthquake-related spinal trauma using MDCT. Methods Features of spinal injuries of 223 Sichuan earthquake-exposed patients and 223 non-earthquake-related spinal injury patients were retrospectively compared using MDCT. The date of non-earthquake-related spinal injury patients was collected from 1 May 2009 to 22 July 2009 to avoid the confounding effects of seasonal activity and clothing. We focused on anatomic sites, injury types and neurologic deficits related to spinal injuries. Major injuries were classified according to the grid 3-3-3 scheme of the Magerl (AO) classification system. Results A total of 185 patients (82.96%) in the earthquake-exposed cohort experienced crush injuries. In the earthquake and control groups, 65 and 92 patients, respectively, had neurologic deficits. The anatomic distribution of these two cohorts was significantly different (P < 0.001). Cervical spinal injuries were more common in the control group (risk ratio (RR) = 2.12, P < 0.001), whereas lumbar spinal injuries were more common in the earthquake-related spinal injuries group (277 of 501 injured vertebrae; 55.29%). The major types of injuries were significantly different between these cohorts (P = 0.002). Magerl AO type A lesions composed most of the lesions seen in both of these cohorts. Type B lesions were more frequently seen in earthquake-related spinal injuries (RR = 1.27), while we observed type C lesions more frequently in subjects with non-earthquake-related spinal injuries (RR = 1.98, P = 0.0029). Conclusions Spinal injuries sustained in the Sichuan earthquake were located mainly in the lumbar spine, with a peak prevalence of type A lesions and a high occurrence of neurologic deficits. The anatomic distribution and type of spinal injuries that varied between earthquake-related and non-earthquake-related spinal injury groups were perhaps due to the different mechanism of injury. PMID:21190568
Digital computer technique for setup and checkout of an analog computer
NASA Technical Reports Server (NTRS)
Ambaruch, R.
1968-01-01
Computer program technique, called Analog Computer Check-Out Routine Digitally /ACCORD/, generates complete setup and checkout data for an analog computer. In addition, the correctness of the analog program implementation is validated.
Understanding Teachers' Routines to Inform Classroom Technology Design
ERIC Educational Resources Information Center
An, Pengcheng; Bakker, Saskia; Eggen, Berry
2017-01-01
Secondary school teachers have quite busy and complex routines in their classrooms. However, present classroom technologies usually require focused attention from teachers while being interacted with, which restricts their use in teachers' daily routines. Peripheral interaction is a human-computer interaction style that aims to enable interaction…
NASA Astrophysics Data System (ADS)
Favalli, A.; Lombardi, M.; MacArthur, D. W.; McCluskey, C.; Moss, C. E.; Paffett, M. T.; Ianakiev, K. D.
2018-01-01
Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. We describe our research to develop such a passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. We present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.
Bahadir, Osman; Kosucu, Polat
2012-12-01
To objectively assess the efficacy of radiofrequency thermal ablation of inferior turbinate hypertrophy. Thirty-five patients with nasal obstruction secondary to inferior turbinate hypertrophy were prospectively enrolled. Radiofrequency energy was delivered to four sites in each inferior turbinate. Patients were evaluated before and 8 weeks after intervention. Subjective evaluation of nasal obstruction was performed using a visual analogue scale (VAS), and objective evaluation of the turbinate volume reduction was calculated using multidetector CT. Volumetric measurements of the preoperative inferior turbinate were compared with postoperative values on both sides. The great majority of patients (91.4%) exhibited subjective postoperative improvement. Mean obstruction (VAS) improved significantly from 7.45±1.48 to 3.54±1.96. Significant turbinate volume reduction was achieved by the surgery on both right and left sides [(preoperative vs. postoperative, right: 6.55±1.62cm(3) vs. 5.10±1.47cm(3), (P<0.01); left: 6.72±1.53cm(3) vs. 5.00±1.37cm(3), (P<0.01)] respectively. Radiofrequency is a safe and effective surgical procedure in reducing turbinate volume in patients with inferior turbinate hypertrophy. Multidetector CT is an objective method of assessment in detecting radiofrequency turbinate volume reduction. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Monochromatic, Rosseland mean, and Planck mean opacity routine
NASA Astrophysics Data System (ADS)
Semenov, D.
2006-11-01
Several FORTRAN77 codes were developed to compute frequency-dependent, Rosseland and Planck mean opacities of gas and dust in protoplanetary disks. The opacities can be computed for an ensemble of dust grains having various compositions (ices, silicates, organics, etc), sizes, topologies (homogeneous/composite aggregates, homogeneous/layered/composite spheres, etc.), porosities, and dust-to-gas ratio. Several examples are available. In addition, a very fast opacity routine to be used in modeling of the radiative transfer in hydro simulations of disks is available upon request (10^8 routine calls require about 30s on Pentium 4 3.0GHz).
A MAP read-routine for IBM 7094 Fortran II binary tapes
Robert S. Helfman
1966-01-01
Two MAP (Macro Assembly Program) language routines are descrived. They permit Fortran IV programs to read binary tapes generated by Fortran II programs, on the IBM 7090 and 7094 computers. One routine is for use with 7040/44-IBSYS, the other for 7090/94-IBSYS.
NASA Astrophysics Data System (ADS)
Ichihara, Takashi; George, Richard T.; Silva, Caterina; Lima, Joao A. C.; Lardo, Albert C.
2011-02-01
The purpose of this study was to develop a quantitative method for myocardial blood flow (MBF) measurement that can be used to derive accurate myocardial perfusion measurements from dynamic multidetector computed tomography (MDCT) images by using a compartment model for calculating the first-order transfer constant (K1) with correction for the capillary transit extraction fraction (E). Six canine models of left anterior descending (LAD) artery stenosis were prepared and underwent first-pass contrast-enhanced MDCT perfusion imaging during adenosine infusion (0.14-0.21 mg/kg/min). K1 , which is the first-order transfer constant from left ventricular (LV) blood to myocardium, was measured using the Patlak plot method applied to time-attenuation curve data of the LV blood pool and myocardium. The results were compared against microsphere MBF measurements, and the extraction fraction of contrast agent was calculated. K1 is related to the regional MBF as K1=EF, E=(1-exp(-PS/F)), where PS is the permeability-surface area product and F is myocardial flow. Based on the above relationship, a look-up table from K1 to MBF can be generated and Patlak plot-derived K1 values can be converted to the calculated MBF. The calculated MBF and microsphere MBF showed a strong linear association. The extraction fraction in dogs as a function of flow (F) was E=(1-exp(-(0.2532F+0.7871)/F)) . Regional MBF can be measured accurately using the Patlak plot method based on a compartment model and look-up table with extraction fraction correction from K1 to MBF.
Chu, Zhi-gang; Yang, Zhi-gang; Dong, Zhi-hui; Chen, Tian-wu; Zhu, Zhi-yu; Deng, Wen; Xiao, Jia-he
2011-10-01
In a massive earthquake, cranio-maxillofacial trauma was common. The present study was to determine the features of cranio-maxillofacial trauma sustained in the massive Sichuan earthquake by multi-detector row computed tomography (MDCT). The study included 221 consecutive patients (123 males and 98 females; age range, 1-83 years; median age, 35 years) with cranio-maxillofacial trauma in the Sichuan earthquake, who underwent cranio-maxillofacial MDCT scans. The image data were retrospectively reviewed focusing on the injuries of the cranio-maxillofacial soft tissue, facial bones and cranium. All patients had soft tissue injuries frequently with foreign bodies. Ninety-seven (43.9%) patients had fractures (1.5 involved sites per patient, range from 1 to 8) including single cranial fractures in 36 (37.1%) cases, single maxillofacial fractures were seen in 48 (49.5%) and cranio-maxillofacial fractures in 13 (13.4%). Single bone fracture was more common than multiple bone fractures (p<0.05). Nasal, ethmoid bones and the orbits were the most commonly involved sites of the craniofacial region. Thirty-eight (17.2%) patients had intracranial injuries, the commonest being subarachnoid haemorrhage and the commonest sites were the temporal and frontal regions. Coexisting intracranial injuries were more common in patients with cranial fractures than in patients with maxillofacial fractures (p<0.05). Our results indicate that the cranio-maxillofacial trauma arising from the massive Sichuan earthquake had some characteristic features, and a significant number of individuals had the potential for combined cranial and maxillofacial injuries, successful management of which required a multidisciplinary approach. Crown Copyright © 2010. Published by Elsevier Ltd. All rights reserved.
Jung, Seung Chai; Cho, Jeong Yeon
2011-01-01
Objective To determine the optimal iodine concentration of contrast media for kidney multidetector computed tomography (MDCT) by comparing the degree of renal parenchymal enhancement and the severity of the renal streak artifact with contrast media of different iodine concentrations. Materials and Methods A 16-row MDCT was performed in 15 sedated rabbits by injection of 2 mL contrast media/kg body weight at a rate of 0.3 mL/sec. Monomeric nonionic contrast media of 250, 300, and 370 mg iodine/mL were injected at 1-week intervals. Mean attenuation values were measured in each renal structure with attenuation differences among the structures. The artifact was evaluated by CT window width/level and three grading methods. The values were compared with iodine concentrations. Results The 370 mg iodine/mL concentration showed significantly higher cortical enhancement than 250 mg iodine/mL in all phases (p < 0.05). There was however no significant difference in the degree of enhancement between the 300 mg iodine/mL and 370 mg iodine/mL concentrations in all phases. There is a significant difference in attenuation for the cortex-outer medulla between 250 mg iodine/mL and 300 mg iodine/mL (p < 0.05). The artifact was more severe with a medium of 370 mg iodine/mL than with 250 mg iodine/mL by all grading methods (p < 0.05). Conclusion The 300 mg iodine/mL is considered to be the most appropriate iodine concentration in an aspect of the enhancement and artifact on a kidney MDCT scan. PMID:22043154
Kim, Inwha; Kim, Dae Jung; Kim, Kyoung Ah; Yoon, Sang Wook; Lee, Jong Tae
2014-01-01
To investigate the feasibility and accuracy of multidetector computed tomography (MDCT) angiography for assessment of subsegmental tumor-feeding vessels in transarterial chemoembolization (TACE) of hepatocellular carcinoma (HCC). A total of 23 patients with 36 HCCs who underwent TACE during a 14-month period were enrolled. All patients underwent 3-phase dynamic MDCT within a month before TACE. Arterial phase MDCT images were retrospectively reformatted and analyzed for determination of single subsegmental tumor-feeding vessel using maximum intensity projection (MIP) and volume-rendering technique (VRT). Two radiologists independently assessed and scored the MIP and VRT images using 4-grade visual scores (grade 1, no depiction of tumor-feeding vessel; grade 2, indeterminate tumor-feeding vessel; grade 3, probable tumor-feeding vessel; and grade 4, good depiction of tumor-feeding vessel). The weighted kappa test was used to determine interobserver variability, and Wilcoxon signed rank test was used to differentiate visual scores of each technique. Results of digital subtraction angiography were defined as the criterion standard; therefore, assessment of subsegmental tumor-feeding vessel using MIP or VRT was compared with digital subtraction angiography, and the accuracy of each technique was calculated. Interobserver agreement (weighted kappa, 0.746 on VRT and 0.806 on MIP) was substantial to almost perfect. The visual scores for MIP (mean, 3.64 for reviewer 1 and 3.5 for reviewer 2) were higher than those for VRT (mean, 2.11 for reviewer 1 and 2.22 for reviewer 2; P = 0.000). The accuracy for assessing subsegmental tumor-feeding vessel was 22.2% for VRT and 77.8% for MIP. Multidetector CT angiography using MIP showed good imaging quality and high accuracy for determination of subsegmental tumor-feeding vessels.
Rib Radiography versus Chest Computed Tomography in the Diagnosis of Rib Fractures.
Sano, Atsushi
2018-05-01
The accurate diagnosis of rib fractures is important in chest trauma. Diagnostic images following chest trauma are usually obtained via chest X-ray, chest computed tomography, or rib radiography. This study evaluated the diagnostic characteristics of rib radiography and chest computed tomography. Seventy-five rib fracture patients who underwent both chest computed tomography and rib radiography between April 2008 and December 2013 were included. Rib radiographs, centered on the site of pain, were taken from two directions. Chest computed tomography was performed using a 16-row multidetector scanner with 5-mm slice-pitch without overlap, and axial images were visualized in a bone window. In total, 217 rib fractures were diagnosed in 75 patients. Rib radiography missed 43 rib fractures in 24 patients. The causes were overlap with organs in 15 cases, trivial fractures in 21 cases, and injury outside the imaging range in 7 cases. Left lower rib fractures were often missed due to overlap with the heart, while middle and lower rib fractures were frequently not diagnosed due to overlap with abdominal organs. Computed tomography missed 21 rib fractures in 17 patients. The causes were horizontal fractures in 10 cases, trivial fractures in 9 cases, and insufficient breath holding in 1 case. In rib radiography, overlap with organs and fractures outside the imaging range were characteristic reasons for missed diagnoses. In chest computed tomography, horizontal rib fractures and insufficient breath holding were often responsible. We should take these challenges into account when diagnosing rib fractures. Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Chang Chien, Kuang-Che; Fetita, Catalin; Brillet, Pierre-Yves; Prêteux, Françoise; Chang, Ruey-Feng
2009-02-01
Multi-detector computed tomography (MDCT) has high accuracy and specificity on volumetrically capturing serial images of the lung. It increases the capability of computerized classification for lung tissue in medical research. This paper proposes a three-dimensional (3D) automated approach based on mathematical morphology and fuzzy logic for quantifying and classifying interstitial lung diseases (ILDs) and emphysema. The proposed methodology is composed of several stages: (1) an image multi-resolution decomposition scheme based on a 3D morphological filter is used to detect and analyze the different density patterns of the lung texture. Then, (2) for each pattern in the multi-resolution decomposition, six features are computed, for which fuzzy membership functions define a probability of association with a pathology class. Finally, (3) for each pathology class, the probabilities are combined up according to the weight assigned to each membership function and two threshold values are used to decide the final class of the pattern. The proposed approach was tested on 10 MDCT cases and the classification accuracy was: emphysema: 95%, fibrosis/honeycombing: 84% and ground glass: 97%.
Takayanagi, Tomoya; Arai, Takehiro; Amanuma, Makoto; Sano, Tomonari; Ichiba, Masato; Ishizaka, Kazumasa; Sekine, Takako; Matsutani, Hideyuki; Morita, Hitomi; Takase, Shinichi
2017-01-01
Coronary computed tomography angiography (CCTA) in patients with pacemaker suffers from metallic lead-induced artifacts, which often interfere with accurate assessment of coronary luminal stenosis. The purpose of this study was to assess a frequency of the lead-induced artifacts and artifact-suppression effect by the single energy metal artifact reduction (SEMAR) technique. Forty-one patients with a dual-chamber pacemaker were evaluated using a 320 multi-detector row CT (MDCT). Among them, 22 patients with motion-free full data reconstruction images were the final candidates. Images with and without the SMEAR technique were subjectively compared, and the degree of metallic artifacts was compared. On images without SEMAR, severe metallic artifacts were often observed in the right coronary artery (#1, #2, #3) and distal anterior descending branch (#8). These artifacts were effectively suppressed by SEMAR, and the luminal accessibility was significantly improved in #3 and #8. While pacemaker leads often cause metallic-induced artifacts, SEMAR technique reduced the artifacts and significantly improved the accessibility of coronary lumen in #3 and #8.
Pediatric Chest and Abdominopelvic CT: Organ Dose Estimation Based on 42 Patient Models
Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.
2014-01-01
Purpose To estimate organ dose from pediatric chest and abdominopelvic computed tomography (CT) examinations and evaluate the dependency of organ dose coefficients on patient size and CT scanner models. Materials and Methods The institutional review board approved this HIPAA–compliant study and did not require informed patient consent. A validated Monte Carlo program was used to perform simulations in 42 pediatric patient models (age range, 0–16 years; weight range, 2–80 kg; 24 boys, 18 girls). Multidetector CT scanners were modeled on those from two commercial manufacturers (LightSpeed VCT, GE Healthcare, Waukesha, Wis; SOMATOM Definition Flash, Siemens Healthcare, Forchheim, Germany). Organ doses were estimated for each patient model for routine chest and abdominopelvic examinations and were normalized by volume CT dose index (CTDIvol). The relationships between CTDIvol-normalized organ dose coefficients and average patient diameters were evaluated across scanner models. Results For organs within the image coverage, CTDIvol-normalized organ dose coefficients largely showed a strong exponential relationship with the average patient diameter (R2 > 0.9). The average percentage differences between the two scanner models were generally within 10%. For distributed organs and organs on the periphery of or outside the image coverage, the differences were generally larger (average, 3%–32%) mainly because of the effect of overranging. Conclusion It is feasible to estimate patient-specific organ dose for a given examination with the knowledge of patient size and the CTDIvol. These CTDIvol-normalized organ dose coefficients enable one to readily estimate patient-specific organ dose for pediatric patients in clinical settings. This dose information, and, as appropriate, attendant risk estimations, can provide more substantive information for the individual patient for both clinical and research applications and can yield more expansive information on dose profiles across patient populations within a practice. © RSNA, 2013 PMID:24126364
Ibáñez Sanz, L; Borruel Nacenta, S; Cano Alonso, R; Díez Martínez, P; Navallas Irujo, M
2015-01-01
Gastrointestinal volvuli cause processes that manifest as acute abdomen. Volvuli are important not because they are common, but rather because their possible complications can be severe. All types of volvuli share a common pathophysiology, which consists of intestinal obstruction in a closed loop that results in ischemia. The clinical manifestations are nonspecific, so radiologists play a very important role in the early identification of the most common signs of torsion. These include the "bird's beak sign", the "whirlpool sign", and signs of potentially reversible or irreversible ischemia. The treatment of choice in most cases is surgery, either to correct the torsion and save the organ or to resect it if it is necrotic. Copyright © 2012 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
A brief review of chronic obstructive pulmonary disease.
Hogg, James C
2012-01-01
A recent study, based on a combination of multidetector computed tomography scanning of an intact specimen with microcomputed tomography and histological analysis of lung tissue samples, reported that the number of terminal bronchioles were reduced from approximately 44,500/lung pair in control (donor) lungs to approximately 4800/lung pair in lungs donated by individuals with very severe (Global initiative for chronic Obstructive Lung Disease stage 4) chronic obstructive pulmonary disease (COPD) treated by lung transplantation. The present short review discusses the hypothesis that a rapid rate of terminal bronchiolar destruction causes the rapid decline in lung function leading to advanced COPD. With respect to why the terminal bronchioles are targeted for destruction, the postulated mechanisms of this destruction and the possibility that new treatments are able to either prevent or reverse the underlying cause of airway obstruction in COPD are addressed.
Gunshot injuries in the neck area: ballistics elements and forensic issues.
Pinto, Antonio; Brunese, Luca; Scaglione, Mariano; Scuderi, Maria Giuseppina; Romano, Luigia
2009-06-01
The neck is an interesting structure as far as penetrating trauma is concerned because of the multiple vital structures that are concentrated in a small anatomic area. Gunshot wounding is an interaction between the penetrating projectile, the anatomy of the wounded subject, and the chance occurrences that determine the exact missile path. The mass and velocity of the projectile establish the upper limit of possible tissue damage. Management of gunshot neck injuries depends on a clear understanding of the anatomy of the neck. The radiologist can contribute substantially to the successful treatment of the patient with a gunshot wound. Important analysis includes the assessment of the missile path in emergency conditions by using plain film and multidetector row computed tomography. The radiologist further evaluates the extent of wounding by determining missile fragmentation and secondary missile paths.
Electrocardiographically gated 16-section CT of the thorax: cardiac motion suppression.
Hofmann, Lars K; Zou, Kelly H; Costello, Philip; Schoepf, U Joseph
2004-12-01
Thirty patients underwent 16-section multi-detector row computed tomographic (CT) angiography of the thorax with retrospective electrocardiographic gating. Institutional review board approval was obtained for retrospective analysis of CT scan data and records; patient informed consent was not required. Images reconstructed at six different time points (0%, 20%, 40%, 50%, 60%, 80%) within the R-R interval on the electrocardiogram were analyzed by two radiologists for diagnostic quality, to identify suitable reconstruction intervals for optimal suppression of cardiac motion. Five regions of interest (left coronary artery, aortic root, ascending and descending aorta, pulmonary arteries) were evaluated. Best image quality was achieved by referencing image reconstruction to middiastole (50%-60%) for the left coronary artery, aortic root, and ascending aorta. The pulmonary arteries are best displayed during mid- to late diastole (80%). (c) RSNA, 2004
That liver lesion on MDCT in the oncology patient: is it important?
Thakrar, Kiran H.; Wenzke, Daniel R.; Newmark, Geraldine M.; Mehta, Uday K.; Berlin, Jonathan W.
2012-01-01
Abstract Multidetector-row computed tomography (MDCT) has become the primary imaging test for the staging and follow-up of most malignancies that originate outside of the central nervous system. Technical advances in this imaging technique have led to significant improvement in the detection of metastatic disease to the liver. An unintended by-product of this improving diagnostic acumen is the discovery of incidental hepatic lesions in oncology patients that in the past remained undetected. These ubiquitous, incidentally identified hepatic lesions have created a management dilemma for both clinicians and radiologists: are these lesions benign or do they represent metastases? Naturally, the answer to this question has profound prognostic and therapeutic implications. In this review, guidelines concerning the diagnosis and management of some of the more common hepatic incidental lesions detected in patients with extrahepatic malignancies are presented. PMID:23023318
Computer Program For Linear Algebra
NASA Technical Reports Server (NTRS)
Krogh, F. T.; Hanson, R. J.
1987-01-01
Collection of routines provided for basic vector operations. Basic Linear Algebra Subprogram (BLAS) library is collection from FORTRAN-callable routines for employing standard techniques to perform basic operations of numerical linear algebra.
{sup 25}Na and {sup 25}Mg fragmentation on {sup 12}C at 9.23 MeV per nucleon at TRIUMF
DOE Office of Scientific and Technical Information (OSTI.GOV)
St-Onge, Patrick; Boisjoli, Mark; Fregeau, Marc-Olivier
2012-10-20
HERACLES is a multidetector that is used to study heavy-ion collisions, with ion beams with an energy range between 8 to 15 MeV per nucleon. It has 78 detectors axially distributed around the beam axis in 6 rings allowing detection of multiple charged fragments from nuclear reactions. HERACLES has 4 different types of detectors, BC408/BaF{sub 2} phoswich, Si/CsI(Tl) telescope, BC408/BC444 phoswich and CsI(Tl) detectors. The multidetector has been run with a radioactive {sup 25}Na beam and a stable {sup 25}Mg beam at 9.23 MeV per nucleon on a carbon target.
Toroid cavity/coil NMR multi-detector
Gerald, II, Rex E.; Meadows, Alexander D.; Gregar, Joseph S.; Rathke, Jerome W.
2007-09-18
An analytical device for rapid, non-invasive nuclear magnetic resonance (NMR) spectroscopy of multiple samples using a single spectrometer is provided. A modified toroid cavity/coil detector (TCD), and methods for conducting the simultaneous acquisition of NMR data for multiple samples including a protocol for testing NMR multi-detectors are provided. One embodiment includes a plurality of LC resonant circuits including spatially separated toroid coil inductors, each toroid coil inductor enveloping its corresponding sample volume, and tuned to resonate at a predefined frequency using a variable capacitor. The toroid coil is formed into a loop, where both ends of the toroid coil are brought into coincidence. Another embodiment includes multiple micro Helmholtz coils arranged on a circular perimeter concentric with a central conductor of the toroid cavity.
High resolution multidetector CT aided tissue analysis and quantification of lung fibrosis
NASA Astrophysics Data System (ADS)
Zavaletta, Vanessa A.; Karwoski, Ronald A.; Bartholmai, Brian; Robb, Richard A.
2006-03-01
Idiopathic pulmonary fibrosis (IPF, also known as Idiopathic Usual Interstitial Pneumontis, pathologically) is a progressive diffuse lung disease which has a median survival rate of less than four years with a prevalence of 15-20/100,000 in the United States. Global function changes are measured by pulmonary function tests and the diagnosis and extent of pulmonary structural changes are typically assessed by acquiring two-dimensional high resolution CT (HRCT) images. The acquisition and analysis of volumetric high resolution Multi-Detector CT (MDCT) images with nearly isotropic pixels offers the potential to measure both lung function and structure. This paper presents a new approach to three dimensional lung image analysis and classification of normal and abnormal structures in lungs with IPF.
Software development to support sensor control of robot arc welding
NASA Technical Reports Server (NTRS)
Silas, F. R., Jr.
1986-01-01
The development of software for a Digital Equipment Corporation MINC-23 Laboratory Computer to provide functions of a workcell host computer for Space Shuttle Main Engine (SSME) robotic welding is documented. Routines were written to transfer robot programs between the MINC and an Advanced Robotic Cyro 750 welding robot. Other routines provide advanced program editing features while additional software allows communicatin with a remote computer aided design system. Access to special robot functions were provided to allow advanced control of weld seam tracking and process control for future development programs.
The development of an engineering computer graphics laboratory
NASA Technical Reports Server (NTRS)
Anderson, D. C.; Garrett, R. E.
1975-01-01
Hardware and software systems developed to further research and education in interactive computer graphics were described, as well as several of the ongoing application-oriented projects, educational graphics programs, and graduate research projects. The software system consists of a FORTRAN 4 subroutine package, in conjunction with a PDP 11/40 minicomputer as the primary computation processor and the Imlac PDS-1 as an intelligent display processor. The package comprises a comprehensive set of graphics routines for dynamic, structured two-dimensional display manipulation, and numerous routines to handle a variety of input devices at the Imlac.
Flynn, Allen J; Bahulekar, Namita; Boisvert, Peter; Lagoze, Carl; Meng, George; Rampton, James; Friedman, Charles P
2017-01-01
Throughout the world, biomedical knowledge is routinely generated and shared through primary and secondary scientific publications. However, there is too much latency between publication of knowledge and its routine use in practice. To address this latency, what is actionable in scientific publications can be encoded to make it computable. We have created a purpose-built digital library platform to hold, manage, and share actionable, computable knowledge for health called the Knowledge Grid Library. Here we present it with its system architecture.
NASA Astrophysics Data System (ADS)
Xu, Ye; Lee, Michael C.; Boroczky, Lilla; Cann, Aaron D.; Borczuk, Alain C.; Kawut, Steven M.; Powell, Charles A.
2009-02-01
Features calculated from different dimensions of images capture quantitative information of the lung nodules through one or multiple image slices. Previously published computer-aided diagnosis (CADx) systems have used either twodimensional (2D) or three-dimensional (3D) features, though there has been little systematic analysis of the relevance of the different dimensions and of the impact of combining different dimensions. The aim of this study is to determine the importance of combining features calculated in different dimensions. We have performed CADx experiments on 125 pulmonary nodules imaged using multi-detector row CT (MDCT). The CADx system computed 192 2D, 2.5D, and 3D image features of the lesions. Leave-one-out experiments were performed using five different combinations of features from different dimensions: 2D, 3D, 2.5D, 2D+3D, and 2D+3D+2.5D. The experiments were performed ten times for each group. Accuracy, sensitivity and specificity were used to evaluate the performance. Wilcoxon signed-rank tests were applied to compare the classification results from these five different combinations of features. Our results showed that 3D image features generate the best result compared with other combinations of features. This suggests one approach to potentially reducing the dimensionality of the CADx data space and the computational complexity of the system while maintaining diagnostic accuracy.
[A UNIX-based electronic data processing system for routine use in a trauma surgery department].
Boos, O; Kinzl, L; Schweiggert, F; Suger, G
1994-05-01
A computer program for a UNIX workstation has been developed to support routine activities in a surgical department. A relational database contains reports on operations, medical letters and further data imported from independent computer subsystems outside the department. Data are accessible at 15 terminals and PCs through a simple and intuitive user interface with a mouse. The patient record is organized in a hypertext fashion and permits direct access to the various types of documents in a consistent manner. The implementation is currently used to manage information on 40,000 patients and has proved valuable in daily routine over a 2-year period.
ERIC Educational Resources Information Center
Lee, Chun-Yi; Chen, Ming-Jang; Chang, Wen-Long
2014-01-01
The aim of this study is to investigate the effects of solution methods and question prompts on generalization and justification of non-routine problem solving for Grade 9 students. The learning activities are based on the context of the frog jumping game. In addition, related computer tools were used to support generalization and justification of…
Ogata, Y; Nishizawa, K
1995-10-01
An automated smear counting and data processing system for a life science laboratory was developed to facilitate routine surveys and eliminate human errors by using a notebook computer. This system was composed of a personal computer, a liquid scintillation counter and a well-type NaI(Tl) scintillation counter. The radioactivity of smear samples was automatically measured by these counters. The personal computer received raw signals from the counters through an interface of RS-232C. The software for the computer evaluated the surface density of each radioisotope and printed out that value along with other items as a report. The software was programmed in Pascal language. This system was successfully applied to routine surveys for contamination in our facility.
Physical analysis of breast cancer using dual-source computed tomography
NASA Astrophysics Data System (ADS)
Kim, H. J.; Lee, H. K.; Cho, J. H.
2014-12-01
This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.
Ascent/descent ancillary data production user's guide
NASA Technical Reports Server (NTRS)
Brans, H. R.; Seacord, A. W., II; Ulmer, J. W.
1986-01-01
The Ascent/Descent Ancillary Data Product, also called the A/D BET because it contains a Best Estimate of the Trajectory (BET), is a collection of trajectory, attitude, and atmospheric related parameters computed for the ascent and descent phases of each Shuttle Mission. These computations are executed shortly after the event in a post-flight environment. A collection of several routines including some stand-alone routines constitute what is called the Ascent/Descent Ancillary Data Production Program. A User's Guide for that program is given. It is intended to provide the reader with all the information necessary to generate an Ascent or a Descent Ancillary Data Product. It includes descriptions of the input data and output data for each routine, and contains explicit instructions on how to run each routine. A description of the final output product is given.
Large Data at Small Universities: Astronomical processing using a computer classroom
NASA Astrophysics Data System (ADS)
Fuller, Nathaniel James; Clarkson, William I.; Fluharty, Bill; Belanger, Zach; Dage, Kristen
2016-06-01
The use of large computing clusters for astronomy research is becoming more commonplace as datasets expand, but access to these required resources is sometimes difficult for research groups working at smaller Universities. As an alternative to purchasing processing time on an off-site computing cluster, or purchasing dedicated hardware, we show how one can easily build a crude on-site cluster by utilizing idle cycles on instructional computers in computer-lab classrooms. Since these computers are maintained as part of the educational mission of the University, the resource impact on the investigator is generally low.By using open source Python routines, it is possible to have a large number of desktop computers working together via a local network to sort through large data sets. By running traditional analysis routines in an “embarrassingly parallel” manner, gains in speed are accomplished without requiring the investigator to learn how to write routines using highly specialized methodology. We demonstrate this concept here applied to 1. photometry of large-format images and 2. Statistical significance-tests for X-ray lightcurve analysis. In these scenarios, we see a speed-up factor which scales almost linearly with the number of cores in the cluster. Additionally, we show that the usage of the cluster does not severely limit performance for a local user, and indeed the processing can be performed while the computers are in use for classroom purposes.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Favalli, A.; Lombardi, M.; MacArthur, D. W.
Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. Here, we describe our research to develop such amore » passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. Finally, we present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.« less
Favalli, A.; Lombardi, M.; MacArthur, D. W.; ...
2017-09-14
Improving the quality of safeguards measurements at Gas Centrifuge Enrichment Plants while reducing the inspection effort is an important objective given the number of existing and new plants that need to be safeguarded. A useful tool in many safeguards approaches is the on-line monitoring of enrichment in process pipes. One requirement of such a monitor is a simple, reliable and precise passive measurement of the 186-keV line from 235U. The other information required is the amount of gas in the pipe, which can be obtained by a transmission or pressure measurement. Here, we describe our research to develop such amore » passive measurement system. Unfortunately, a complication arises in the interpretation of the gamma measurements, from the contribution of uranium deposits on the wall of the pipe to the 186-keV peak. A multi-detector approach to address this complication is presented where two measurements, one with signal primarily from gas and one with signal primarily from deposits, are performed simultaneously with different detectors and geometries. This allows a correction to be made to the 186-keV peak for the contribution from the deposit. Finally, we present the design of the multi-detector system and the results of the experimental calibration of the proof-of-principle prototype built at LANL.« less
Image analysis library software development
NASA Technical Reports Server (NTRS)
Guseman, L. F., Jr.; Bryant, J.
1977-01-01
The Image Analysis Library consists of a collection of general purpose mathematical/statistical routines and special purpose data analysis/pattern recognition routines basic to the development of image analysis techniques for support of current and future Earth Resources Programs. Work was done to provide a collection of computer routines and associated documentation which form a part of the Image Analysis Library.
ADMAP (automatic data manipulation program)
NASA Technical Reports Server (NTRS)
Mann, F. I.
1971-01-01
Instructions are presented on the use of ADMAP, (automatic data manipulation program) an aerospace data manipulation computer program. The program was developed to aid in processing, reducing, plotting, and publishing electric propulsion trajectory data generated by the low thrust optimization program, HILTOP. The program has the option of generating SC4020 electric plots, and therefore requires the SC4020 routines to be available at excution time (even if not used). Several general routines are present, including a cubic spline interpolation routine, electric plotter dash line drawing routine, and single parameter and double parameter sorting routines. Many routines are tailored for the manipulation and plotting of electric propulsion data, including an automatic scale selection routine, an automatic curve labelling routine, and an automatic graph titling routine. Data are accepted from either punched cards or magnetic tape.
Computer mouse movement patterns: A potential marker of mild cognitive impairment.
Seelye, Adriana; Hagler, Stuart; Mattek, Nora; Howieson, Diane B; Wild, Katherine; Dodge, Hiroko H; Kaye, Jeffrey A
2015-12-01
Subtle changes in cognitively demanding activities occur in MCI but are difficult to assess with conventional methods. In an exploratory study, we examined whether patterns of computer mouse movements obtained from routine home computer use discriminated between older adults with and without MCI. Participants were 42 cognitively intact and 20 older adults with MCI enrolled in a longitudinal study of in-home monitoring technologies. Mouse pointer movement variables were computed during one week of routine home computer use using algorithms that identified and characterized mouse movements within each computer use session. MCI was associated with making significantly fewer total mouse moves ( p <.01), and making mouse movements that were more variable, less efficient, and with longer pauses between movements ( p <.05). Mouse movement measures were significantly associated with several cognitive domains ( p 's<.01-.05). Remotely monitored computer mouse movement patterns are a potential early marker of real-world cognitive changes in MCI.
Stomach arteriovenous malformation resected by laparoscopy-assisted surgery: A case report.
Hotta, Masahiro; Yamamoto, Kazuhito; Cho, Kazumitsu; Takao, Yoshimune; Fukuoka, Takeshi; Uchida, Eiji
2016-05-01
Arteriovenous malformations of the stomach are an uncommon cause of upper GI bleeding. We report a case of stomach arteriovenous malformation in an 85-year-old Asian man who presented with massive hematemesis. Initial esophagogastroduodenoscopy did not detect this lesion, but contrast multi-detector CT confirmed GI bleeding. Multi-detector CT revealed a mass of blood vessels underlying the submucosa that arose from the right gastroepiploic artery. Repeat esophagogastroduodenoscopy showed that the lesion was a submucosal tumor with erosion and without active bleeding in the lower body of the stomach on the greater curvature. We performed partial gastrectomy via laparoscopy-assisted surgery. The histopathological diagnosis was arteriovenous malformation. © 2016 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
Validity of Computer Adaptive Tests of Daily Routines for Youth with Spinal Cord Injury
Haley, Stephen M.
2013-01-01
Objective: To evaluate the accuracy of computer adaptive tests (CATs) of daily routines for child- and parent-reported outcomes following pediatric spinal cord injury (SCI) and to evaluate the validity of the scales. Methods: One hundred ninety-six daily routine items were administered to 381 youths and 322 parents. Pearson correlations, intraclass correlation coefficients (ICC), and 95% confidence intervals (CI) were calculated to evaluate the accuracy of simulated 5-item, 10-item, and 15-item CATs against the full-item banks and to evaluate concurrent validity. Independent samples t tests and analysis of variance were used to evaluate the ability of the daily routine scales to discriminate between children with tetraplegia and paraplegia and among 5 motor groups. Results: ICC and 95% CI demonstrated that simulated 5-, 10-, and 15-item CATs accurately represented the full-item banks for both child- and parent-report scales. The daily routine scales demonstrated discriminative validity, except between 2 motor groups of children with paraplegia. Concurrent validity of the daily routine scales was demonstrated through significant relationships with the FIM scores. Conclusion: Child- and parent-reported outcomes of daily routines can be obtained using CATs with the same relative precision of a full-item bank. Five-item, 10-item, and 15-item CATs have discriminative and concurrent validity. PMID:23671380
From macro-scale to micro-scale computational anatomy: a perspective on the next 20 years.
Mori, Kensaku
2016-10-01
This paper gives our perspective on the next two decades of computational anatomy, which has made great strides in the recognition and understanding of human anatomy from conventional clinical images. The results from this field are now used in a variety of medical applications, including quantitative analysis of organ shapes, interventional assistance, surgical navigation, and population analysis. Several anatomical models have also been used in computational anatomy, and these mainly target millimeter-scale shapes. For example, liver-shape models are almost completely modeled at the millimeter scale, and shape variations are described at such scales. Most clinical 3D scanning devices have had just under 1 or 0.5 mm per voxel resolution for over 25 years, and this resolution has not changed drastically in that time. Although Z-axis (head-to-tail direction) resolution has been drastically improved by the introduction of multi-detector CT scanning devices, in-plane resolutions have not changed very much either. When we look at human anatomy, we can see different anatomical structures at different scales. For example, pulmonary blood vessels and lung lobes can be observed in millimeter-scale images. If we take 10-µm-scale images of a lung specimen, the alveoli and bronchiole regions can be located in them. Most work in millimeter-scale computational anatomy has been done by the medical-image analysis community. In the next two decades, we encourage our community to focus on micro-scale computational anatomy. In this perspective paper, we briefly review the achievements of computational anatomy and its impacts on clinical applications; furthermore, we show several possibilities from the viewpoint of microscopic computational anatomy by discussing experimental results from our recent research activities. Copyright © 2016 Elsevier B.V. All rights reserved.
Solid rocket booster performance evaluation model. Volume 4: Program listing
NASA Technical Reports Server (NTRS)
1974-01-01
All subprograms or routines associated with the solid rocket booster performance evaluation model are indexed in this computer listing. An alphanumeric list of each routine in the index is provided in a table of contents.
Stähli, Barbara E.; Nguyen-Kim, Thi Dan Linh; Gebhard, Cathérine; Frauenfelder, Thomas; Tanner, Felix C.; Nietlispach, Fabian; Maisano, Francesco; Falk, Volkmar; Lüscher, Thomas F.; Maier, Willibald; Binder, Ronald K.
2015-01-01
Low-flow low-gradient severe aortic stenosis (LFLGAS) is associated with worse outcomes. Aortic valve calcification patterns of LFLGAS as compared to non-LFLGAS have not yet been thoroughly assessed. 137 patients undergoing transcatheter aortic valve replacement (TAVR) with preprocedural multidetector computed tomography (MDCT) and postprocedural transthoracic echocardiography were enrolled. Calcification characteristics were assessed by MDCT both for the total aortic valve and separately for each leaflet. 34 patients had LFLGAS and 103 non-LFLGAS. Total aortic valve calcification volume (p < 0.001), mass (p < 0.001), and density (p = 0.004) were lower in LFLGAS as compared to non-LFLGAS patients. At 30-day follow-up, mean transaortic pressure gradients and more than mild paravalvular regurgitation did not differ between groups. In conclusion, LFLGAS and non-LFLGAS express different calcification patterns which, however, did not impact on device success after TAVR. PMID:26435875
Small bowel volvulus with jejunal diverticulum: Primary or secondary?
Shen, Xiao-Fei; Guan, Wen-Xian; Cao, Ke; Wang, Hao; Du, Jun-Feng
2015-09-28
Small bowel volvulus, which is torsion of the small bowel and its mesentery, is a medical emergency, and is categorized as primary or secondary type. Primary type often occurs without any apparent intrinsic anatomical anomalies, while the secondary type is common clinically and could be caused by numerous factors including postoperative adhesions, intestinal diverticulum, and/or tumors. Here, we report a rare case of a 60-year-old man diagnosed with small bowel volvulus using multidetector computed tomography (MDCT) angiography. Further discovery by laparotomy showed one jejunal diverticulum, longer corresponding mesentery with a narrower insertion, and a lack of mesenteric fat. This case report includes several etiological factors of small bowel volvulus, and we discuss the possible cause of small bowel volvulus in this patient. We also highlight the importance of MDCT angiography in the diagnosis of volvulus and share our experience in treating this disease.
Small bowel volvulus with jejunal diverticulum: Primary or secondary?
Shen, Xiao-Fei; Guan, Wen-Xian; Cao, Ke; Wang, Hao; Du, Jun-Feng
2015-01-01
Small bowel volvulus, which is torsion of the small bowel and its mesentery, is a medical emergency, and is categorized as primary or secondary type. Primary type often occurs without any apparent intrinsic anatomical anomalies, while the secondary type is common clinically and could be caused by numerous factors including postoperative adhesions, intestinal diverticulum, and/or tumors. Here, we report a rare case of a 60-year-old man diagnosed with small bowel volvulus using multidetector computed tomography (MDCT) angiography. Further discovery by laparotomy showed one jejunal diverticulum, longer corresponding mesentery with a narrower insertion, and a lack of mesenteric fat. This case report includes several etiological factors of small bowel volvulus, and we discuss the possible cause of small bowel volvulus in this patient. We also highlight the importance of MDCT angiography in the diagnosis of volvulus and share our experience in treating this disease. PMID:26420976
NASA Astrophysics Data System (ADS)
Petruse, Radu Emanuil; Batâr, Sergiu; Cojan, Adela; Maniţiu, Ioan
2014-11-01
Coronary computed tomography angiography (CCTA) allows coronary artery visualization and the detection of coronary stenoses. In addition; it has been suggested as a novel, noninvasive modality for coronary atherosclerotic plaque detection, characterization, and quantification. Accurate identification of coronary plaques is challenging, especially for the noncalcified plaques, due to many factors such as the small size of coronary arteries, reconstruction artifacts caused by irregular heartbeats, beam hardening, and partial volume averaging. The development of 16, 32, 64 and the latest 320 row multidetector CT not only increases the spatial and the temporal resolution significantly, but also increases the number of images to be interpreted by radiologists substantially. Radiologists have to visually examine each coronary artery for suspicious stenosis using visualization tools such as multiplanar reformatting (MPR) and curved planar reformatting (CPR) provided by the review workstation in clinical practice
Imaging of Hereditary Hemorrhagic Telangiectasia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carette, Marie-France, E-mail: marie-france.carette@tnn.aphp.fr; Nedelcu, Cosmina; Tassart, Marc
This pictorial review is based on our experience of the follow-up of 120 patients at our multidisciplinary center for hereditary hemorrhagic telangiectasia (HHT). Rendu-Osler-Weber disease or HHT is a multiorgan autosomal dominant disorder with high penetrance, characterized by epistaxis, mucocutaneous telangiectasis, and visceral arteriovenous malformations (AVMs). The research on gene mutations is fundamental and family screening by clinical examination, chest X-ray, research of pulmonary shunting, and abdominal color Doppler sonography is absolutely necessary. The angioarchitecture of pulmonary AVMs can be studied by unenhanced multidetector computed tomography; however, all other explorations of liver, digestive bowels, or brain require administration of contrastmore » media. Magnetic resonance angiography is helpful for central nervous system screening, in particular for the spinal cord, but also for pulmonary, hepatic, and pelvic AVMs. Knowledge of the multiorgan involvement of HHT, mechanism of complications, and radiologic findings is fundamental for the correct management of these patients.« less
CT, MRI and PET imaging in peritoneal malignancy
Sahdev, Anju; Reznek, Rodney H.
2011-01-01
Abstract Imaging plays a vital role in the evaluation of patients with suspected or proven peritoneal malignancy. Nevertheless, despite significant advances in imaging technology and protocols, assessment of peritoneal pathology remains challenging. The combination of complex peritoneal anatomy, an extensive surface area that may host tumour deposits and the considerable overlap of imaging appearances of various peritoneal diseases often makes interpretation difficult. Contrast-enhanced multidetector computed tomography (MDCT) remains the most versatile tool in the imaging of peritoneal malignancy. However, conventional and emerging magnetic resonance imaging (MRI) and positron emission tomography (PET)/CT techniques offer significant advantages over MDCT in detection and surveillance. This article reviews established and new techniques in CT, MRI and PET imaging in both primary and secondary peritoneal malignancies and provides an overview of peritoneal anatomy, function and modes of disease dissemination with illustration of common sites and imaging features of peritoneal malignancy. PMID:21865109
Diagnosis of blunt traumatic aortic injury 2007: still a nemesis.
Mirvis, Stuart E; Shanmuganathan, K
2007-10-01
In recent years, the use of multidetector computed tomography (MDCT) for the diagnosis of acute thoracic injury in blunt trauma has expanded. MDCT has shown high accuracy for the diagnosis or exclusion of injury to the aorta and its primary branches, decreasing the need for thoracic angiography and allowing earlier treatment of this often rapidly fatal lesion. With increasing use of MDCT, more subtle injuries and variants of vascular anatomy are being recognized that create pitfalls in the diagnosis. Of perhaps more concern is the recognition that aortic injury can occur with little or no associated mediastinal hematoma, the principle chest radiographic finding indicating a need for further imaging. The importance of recognizing unusual sites of aortic injury, congenital variants of mediastinal anatomy, the precise extent of injury, and the anatomic pathology present as key factors in deciding among treatment options is emphasized.
Busireddy, Kiran K; AlObaidy, Mamdoh; Ramalho, Miguel; Kalubowila, Janaka; Baodong, Liu; Santagostino, Ilaria; Semelka, Richard C
2014-01-01
Pancreatitis is defined as the inflammation of the pancreas and considered the most common pancreatic disease in children and adults. Imaging plays a significant role in the diagnosis, severity assessment, recognition of complications and guiding therapeutic interventions. In the setting of pancreatitis, wider availability and good image quality make multi-detector contrast-enhanced computed tomography (MD-CECT) the most used imaging technique. However, magnetic resonance imaging (MRI) offers diagnostic capabilities similar to those of CT, with additional intrinsic advantages including lack of ionizing radiation and exquisite soft tissue characterization. This article reviews the proposed definitions of revised Atlanta classification for acute pancreatitis, illustrates a wide range of morphologic pancreatic parenchymal and associated peripancreatic changes for different types of acute pancreatitis. It also describes the spectrum of early and late chronic pancreatitis imaging findings and illustrates some of the less common types of chronic pancreatitis, with special emphasis on the role of CT and MRI. PMID:25133027
First measurement with a new setup for low-energy Coulomb excitation studies at INFN LNL
NASA Astrophysics Data System (ADS)
Rocchini, M.; Hadyńska-Klȩk, K.; Nannini, A.; Valiente-Dobón, J. J.; Goasduff, A.; Testov, D.; John, P. R.; Mengoni, D.; Zielińska, M.; Bazzacco, D.; Benzoni, G.; Boso, A.; Cocconi, P.; Chiari, M.; Doherty, D. T.; Galtarossa, F.; Jaworski, G.; Komorowska, M.; Matejska-Minda, M.; Melon, B.; Menegazzo, R.; Napiorkowski, P.; Napoli, D. R.; Ottanelli, M.; Perego, A.; Ramina, L.; Rampazzo, M.; Recchia, F.; Riccetto, S.; Rosso, D.; Siciliano, M.; Sona, P.
2017-07-01
A new segmented particle detector, SPIDER, has been designed to be used as an ancillary device with the GALILEO γ-ray spectrometer, as well as with other multi-detector γ-ray arrays that will be available at LNL in the future (e.g. AGATA). To commission the SPIDER-GALILEO experimental setup, a multi-step Coulomb excitation experiment was carried out with a 240 MeV beam of 66Zn produced by the Tandem-XTU accelerator at INFN Laboratori Nazionali di Legnaro. The measured particle and γ-ray spectra are compared with the results of detailed GEANT4 simulations which used the Coulomb excitation cross sections, estimated with the computer code GOSIA, as an input. The preliminary results indicate that precise transition probabilities will be obtained which are essential for solving discrepancies reported in the literature for this nucleus.
NASA Technical Reports Server (NTRS)
Troiani, N.; Yerazunis, S. W.
1978-01-01
An autonomous roving science vehicle that relies on terrain data acquired by a hierarchy of sensors for navigation was one method of carrying out such a mission. The hierarchy of sensors included a short range sensor with sufficient resolution to detect every possible obstacle and with the ability to make fast and reliable terrain characterizations. A multilaser, multidetector triangulation system was proposed as a short range sensor. The general system was studied to determine its perception capabilities and limitations. A specific rover and low resolution sensor system was then considered. After studying the data obtained, a hazard detection algorithm was developed that accounts for all possible terrains given the sensor resolution. Computer simulation of the rover on various terrains was used to test the entire hazard detection system.
Tracheobronchomegaly associated tracheomalacia: analysis by sleep study.
Sundaram, P; Joshi, J M
2004-01-01
Tracheobronchomegaly (TBM) occasionally may progress to extensive tracheomalacia which leads to respiratory failure. Spirometry, dynamic expiratory multidetector computed tomography (CT), bronchoscopy are used to diagnose patients of suspected tracheobronchomalacia. We used the technique of night-time monitoring of respiratory variables to show the presence of respiratory abnormalities during sleep and which was corrected by applying nasal continuous positive airway pressure (CPAP). The study showed the presence of both apnoea and hypopnoeas, which were obstructive in nature with an apnoea-hypopnoea index (AHI) of 11, no snoring and associated oxygen desaturation of 75 per cent. A second overnight study with nasal continuous positive airway pressure at a critical pressure of 8 cm, the AHI decreased to 3 along with no drop in oxygen saturation. This non-invasive technique should be considered as a diagnostic tool in tracheobronchomalacia and to know the outcome of CPAP, surgical or stent therapy in this condition.
Arora, Ankit; Acharya, Shashi Rashmi; Saraswathi, Muliya Vidya; Sharma, Padmaja; Ather, Amber
2013-08-01
The mesiobuccal root of the maxillary molars is well known to pose a hindrance during endodontic therapy. Presented here is a case of a maxillary left second molar where three canals were located in its mesiobuccal root with the use of visual and diagnostic aids. Difficulties encountered during the process of unveiling the tooth's internal anatomy were discussed. The dilemmas encountered pertained to the root canal configuration, the nomenclature of the extra canals, and the justification for the presence of a third canal. The root canal configuration of 3-2-1 was confirmed for the mesiobuccal root using information gained from clinical, radiographic, and multi-detector computed tomography (MDCT) scan findings. This case demonstrates the need for efforts to locate extra canals in the mesiobuccal root of the maxillary molars as their internal anatomy remains a mystery.
Iacob, Nicoleta; Pusztai, Agneta Maria; Miclăuş, Graţian Dragoslav; Pop, Elena; Matusz, Petru
2018-01-01
The authors describe a case of a 61-year-old female patient, which presented on multidetector computed tomographic (MDCT) angiography a gastrosplenic trunk (GST) and common hepatic artery (CHA) arose independently from abdominal aorta (AA). The GST arose from the anterior wall of the AA, at the level of upper edge of the L1 vertebral body. The left gastric artery (LGA) arose from the superior wall of the GST. The splenic artery (SA) continuous the path of GST. The CHA arose from the anterior wall of the AA, at the level of upper one third of the L1 vertebral body, at 15.3 mm above the origin of superior mesenteric artery (SMA). The incidence and developmental and clinical significance of this vascular variation is discussed with a detailed review of the literature.
Kim, Sangroh; Yoshizumi, Terry T; Toncheva, Greta; Frush, Donald P; Yin, Fang-Fang
2010-03-01
The purpose of this study was to establish a dose estimation tool with Monte Carlo (MC) simulations. A 5-y-old paediatric anthropomorphic phantom was computed tomography (CT) scanned to create a voxelised phantom and used as an input for the abdominal cone-beam CT in a BEAMnrc/EGSnrc MC system. An X-ray tube model of the Varian On-Board Imager((R)) was built in the MC system. To validate the model, the absorbed doses at each organ location for standard-dose and low-dose modes were measured in the physical phantom with MOSFET detectors; effective doses were also calculated. In the results, the MC simulations were comparable to the MOSFET measurements. This voxelised phantom approach could produce a more accurate dose estimation than the stylised phantom method. This model can be easily applied to multi-detector CT dosimetry.
1984-12-01
BLOCK DATA Default values for variables input by menus. LIBR Interface with frame I/O routines. SNSR Interface with sensor routines. ATMOS Interface with...Routines Included in Frame I/O Interface Routine Description LIBR Selects options for input or output to a data library. FRREAD Reads frame from file and/or...Layer", Journal of Applied Meteorology 20, pp. 242-249, March 1981. 15 L.J. Harding, Numerical Analysis and Applications Software Abstracts, Computing
NASA Technical Reports Server (NTRS)
1984-01-01
The structure of the program, the five priority levels, the drive routines, the stepwise drive plan, the figure routines, meander X and y, the range of measurement table, the optimization of figure drive, the figure drive plan, dialogue routines, stack processing, the drive for the main terminal, the protocol routines, the drive for the microterminal, the drive for the experiment computer, and the main program are discussed.
Floating-point function generation routines for 16-bit microcomputers
NASA Technical Reports Server (NTRS)
Mackin, M. A.; Soeder, J. F.
1984-01-01
Several computer subroutines have been developed that interpolate three types of nonanalytic functions: univariate, bivariate, and map. The routines use data in floating-point form. However, because they are written for use on a 16-bit Intel 8086 system with an 8087 mathematical coprocessor, they execute as fast as routines using data in scaled integer form. Although all of the routines are written in assembly language, they have been implemented in a modular fashion so as to facilitate their use with high-level languages.
Real time computer data system for the 40 x 80 ft wind tunnel facility at Ames Research Center
NASA Technical Reports Server (NTRS)
Cambra, J. M.; Tolari, G. P.
1974-01-01
The wind tunnel realtime computer system is a distributed data gathering system that features a master computer subsystem, a high speed data gathering subsystem, a quick look dynamic analysis and vibration control subsystem, an analog recording back-up subsystem, a pulse code modulation (PCM) on-board subsystem, a communications subsystem, and a transducer excitation and calibration subsystem. The subsystems are married to the master computer through an executive software system and standard hardware and FORTRAN software interfaces. The executive software system has four basic software routines. These are the playback, setup, record, and monitor routines. The standard hardware interfaces along with the software interfaces provide the system with the capability of adapting to new environments.
TU-FG-201-04: Computer Vision in Autonomous Quality Assurance of Linear Accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, H; Jenkins, C; Yu, S
Purpose: Routine quality assurance (QA) of linear accelerators represents a critical and costly element of a radiation oncology center. Recently, a system was developed to autonomously perform routine quality assurance on linear accelerators. The purpose of this work is to extend this system and contribute computer vision techniques for obtaining quantitative measurements for a monthly multi-leaf collimator (MLC) QA test specified by TG-142, namely leaf position accuracy, and demonstrate extensibility for additional routines. Methods: Grayscale images of a picket fence delivery on a radioluminescent phosphor coated phantom are captured using a CMOS camera. Collected images are processed to correct formore » camera distortions, rotation and alignment, reduce noise, and enhance contrast. The location of each MLC leaf is determined through logistic fitting and a priori modeling based on knowledge of the delivered beams. Using the data collected and the criteria from TG-142, a decision is made on whether or not the leaf position accuracy of the MLC passes or fails. Results: The locations of all MLC leaf edges are found for three different picket fence images in a picket fence routine to 0.1mm/1pixel precision. The program to correct for image alignment and determination of leaf positions requires a runtime of 21– 25 seconds for a single picket, and 44 – 46 seconds for a group of three pickets on a standard workstation CPU, 2.2 GHz Intel Core i7. Conclusion: MLC leaf edges were successfully found using techniques in computer vision. With the addition of computer vision techniques to the previously described autonomous QA system, the system is able to quickly perform complete QA routines with minimal human contribution.« less
Inokuchi, Go; Yajima, Daisuke; Hayakawa, Mutsumi; Motomura, Ayumi; Chiba, Fumiko; Torimitsu, Suguru; Makino, Yohsuke; Iwase, Hirotaro
2013-12-01
Historically, coronary angiography of the isolated heart has played an important role in the detection of stenotic or occlusive lesions that are difficult to identify by autopsy alone. Meanwhile, although the application of multidetector computed tomography (MDCT) to forensic fields has accelerated recently, isolated single organ angiography with MDCT is rarely performed. In this article, we present an evaluation of postmortem selective coronary CT angiography of the isolated heart with MDCT and discuss its utility for autopsy. First, in a preliminary experiment using pig coronary artery, we examined the behavior of water soluble contrast material on postmortem computed tomography angiography (PMCTA) and found that better angiographic images were acquired when the viscosity of the contrast material was increased and CT was performed under conditions of sustained perfusion. Based on these results, we devised a selective coronary angiography procedure using a pressurized bag for drip infusion that can be performed easily, quickly, and at low cost. The angiographic images obtained provided useful supportive evidence of autopsy findings suggestive of ischemic heart disease. With active discussions underway in forensic fields on the proper use of postmortem computed tomography, PMCTA has also naturally attracted attention as it compensates for some of the shortcomings of CT alone. Although PMCTA typically involves whole-body angiography, if we view PMCTA as one of the many useful and supplementary tools available for autopsy, then isolated heart angiography continues to have utility in autopsy today.
Bret-Zurita, Montserrat; Cuesta, Emilio; Cartón, Antonio; Díez, Jesús; Aroca, Ángel; Oliver, José M; Gutiérrez-Larraya, Federico
2014-11-01
Although congenital heart defects are the most common major congenital abnormalities, the associated mortality has been decreasing due to improvements in their diagnosis and treatment. We assessed the usefulness of 64-multidetector computed tomography in the diagnosis and management of these patients. This 5-year observational, analytical, retrospective, cohort study included a total of 222 tomographic studies of patients with congenital heart disease. Computed tomography scans were read twice and medical records were reviewed. We assessed the complexity of the disease, patient, and radiological technique, and evaluated the contribution of new data in relation to clinical suspicion and diagnostic change. A confidence interval was set at 95% and a P value of<.05 was used as the cutoff for statistical significance. In 35.1% of patients, the treatment procedure was performed after computed tomography without other tests. Additional diagnostic catheterization was performed in 12.5% of patients. There were new findings in 77% of patients (82.9% with complex disease), which prompted a change in patient management in 35.6%. All unexpected reports described new findings. No significant differences were found by age, sex, study period, urgency of the test order, patient complexity, or difficulty of the technique. Use of 64-detector computed tomography yields good diagnostic performance in congenital heart disease, prompts changes in management in more than one-third of patients, and reveals new findings in relation to the presumed diagnosis in 77% of patients. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Benchmark Lisp And Ada Programs
NASA Technical Reports Server (NTRS)
Davis, Gloria; Galant, David; Lim, Raymond; Stutz, John; Gibson, J.; Raghavan, B.; Cheesema, P.; Taylor, W.
1992-01-01
Suite of nonparallel benchmark programs, ELAPSE, designed for three tests: comparing efficiency of computer processing via Lisp vs. Ada; comparing efficiencies of several computers processing via Lisp; or comparing several computers processing via Ada. Tests efficiency which computer executes routines in each language. Available for computer equipped with validated Ada compiler and/or Common Lisp system.
Improved Air Combat Awareness; with AESA and Next-Generation Signal Processing
2002-09-01
competence network Building techniques Software development environment Communication Computer architecture Modeling Real-time programming Radar...memory access, skewed load and store, 3.2 GB/s BW • Performance: 400 MFLOPS Runtime environment Custom runtime routines Driver routines Hardware
Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations
NASA Astrophysics Data System (ADS)
Krimmer, J.; Chevallier, M.; Constanzo, J.; Dauvergne, D.; De Rydt, M.; Dedes, G.; Freud, N.; Henriquet, P.; La Tessa, C.; Létang, J. M.; Pleskač, R.; Pinto, M.; Ray, C.; Reithinger, V.; Richard, M. H.; Rinaldi, I.; Roellinghoff, F.; Schuy, C.; Testa, E.; Testa, M.
2015-01-01
Longitudinal prompt-gamma ray profiles have been measured with a multi-slit multi-detector configuration at a 75 MeV/u 13C beam and with a PMMA target. Selections in time-of-flight and energy have been applied in order to discriminate prompt-gamma rays produced in the target from background events. The ion ranges which have been extracted from each individual detector module agree amongst each other and are consistent with theoretical expectations. In a separate dedicated experiment with 200 MeV/u 12C ions the fraction of inter-detector scattering has been determined to be on the 10%-level via a combination of experimental results and simulations. At the same experiment different collimator configurations have been tested and the shielding properties of tungsten and lead for prompt-gamma rays have been measured.
Dong, J; Hayakawa, Y; Kober, C
2014-01-01
When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.
NASA Astrophysics Data System (ADS)
Netwong, Y.; Krisanachinda, A.
2016-03-01
The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.
Extraction and visualization of the central chest lymph-node stations
NASA Astrophysics Data System (ADS)
Lu, Kongkuo; Merritt, Scott A.; Higgins, William E.
2008-03-01
Lung cancer remains the leading cause of cancer death in the United States and is expected to account for nearly 30% of all cancer deaths in 2007. Central to the lung-cancer diagnosis and staging process is the assessment of the central chest lymph nodes. This assessment typically requires two major stages: (1) location of the lymph nodes in a three-dimensional (3D) high-resolution volumetric multi-detector computed-tomography (MDCT) image of the chest; (2) subsequent nodal sampling using transbronchial needle aspiration (TBNA). We describe a computer-based system for automatically locating the central chest lymph-node stations in a 3D MDCT image. Automated analysis methods are first run that extract the airway tree, airway-tree centerlines, aorta, pulmonary artery, lungs, key skeletal structures, and major-airway labels. This information provides geometrical and anatomical cues for localizing the major nodal stations. Our system demarcates these stations, conforming to criteria outlined for the Mountain and Wang standard classification systems. Visualization tools within the system then enable the user to interact with these stations to locate visible lymph nodes. Results derived from a set of human 3D MDCT chest images illustrate the usage and efficacy of the system.
[Contrast-enhanced ultrasound in animal models].
Paprottka, P M; Zengel, P; Ingrisch, M; Cyran, C C; Eichhorn, M; Reiser, M F; Nikolaou, K; Clevert, D-A
2011-06-01
In the past the detection of tumor perfusion was achieved solely via invasive procedures, such as intravital microscopy or with the help of costly modalities, such as multidetector computed tomography (MDCT), magnetic resonance tomography (MRT) or the combined use of positron emission tomography and computed tomography (PET/CT). Ultrasound offers the non-invasive display of organs without usage of ionizing radiation and it is widely available. However, colour-coded ultrasound and power Doppler do not allow the detection of tumor microcirculation. The introduction of contrast-enhanced ultrasound (CEUS) as well as new high-frequency ultrasound probes made it possible to detect and quantify tumor microcirculation with high resolution. CEUS has been used clinically on human beings for more than 10 years. During the last years different tumor models in experimental animals were used for the establishment of this new technique, e.g. in rats, hamsters and mice. CEUS allows the detection of functional parameters, such as the angiogenetic metabolic status of tissue pretreatment and posttreatment. Further research is required to solve the problems of absolute quantification of these perfusion parameters to allow the comparison of CEUS with other modalities (e.g. MRT and CT).
Tsai, I-Chen; Lin, Yung-Kai; Chang, Yen; Fu, Yun-Ching; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen; Jan, Sheng-Ling; Wang, Kuo-Yang; Chen, Min-Chi; Chen, Clayton Chi-Chang
2009-04-01
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.
Gupta, Pushpender; Barnwell, Jonathan C; Lenchik, Leon; Wuertzer, Scott D; Miller, Anna N
2016-06-01
The objective of the present study is to evaluate multidetector computed tomographic (MDCT) fracture patterns and associated injuries in patients with spinopelvic dissociation (SPD). Our institutional trauma registry database was reviewed from Jan. 1, 2006, to Sept. 30, 2012, specifically evaluating patients with sacral fractures. MDCT scans of patients with sacral fractures were reviewed to determine the presence of SPD. SPD cases were characterized into the following fracture patterns: U-shaped, Y-shaped, T-shaped, H-shaped, and burst. The following MDCT features were recorded: level of the horizontal fracture, location of vertical fracture, kyphosis between major fracture fragments, displacement of fracture fragment, narrowing of central spinal canal, narrowing of neural foramina, and extension into sacroiliac joints. Quantitative evaluation of the sacral fractures was performed in accordance with the consensus statement by the Spine Trauma Study Group. Medical records were reviewed to determine associated pelvic and non-pelvic fractures, bladder and bowel injuries, nerve injuries, and type of surgical intervention. Twenty-one patients had SPD, of whom 13 were men and eight were women. Mean age was 41.8 years (range 18.8 to 87.7). Five fractures (24 %) were U-shaped, six (29 %) H-shaped, four (19 %) Y-shaped, and six (29 %) burst. Nine patients (43 %) had central canal narrowing, and 19 (90 %) had neural foramina narrowing. Eleven patients (52 %) had kyphotic angulation between major fracture fragments, and seven patients (33 %) had either anterior (24 %) or posterior (10 %) displacement of the proximal fracture fragment. Fourteen patients (67 %) had associated pelvic fractures, and 20 (95 %) had associated non-pelvic fractures. Two patients (10 %) had associated urethral injuries, and one (5 %) had an associated colon injury. Seven patients (33 %) had associated nerve injuries. Six patients (29 %) had surgical fixation while 15 (71 %) were managed non-operatively. On trauma MDCT examinations, patients with SPD have characteristic fracture patterns. It is important to differentiate SPD from other pelvic ring injuries due to high rate of associated injuries. Although all SPD injuries are unstable and need fixation, the decision for operative management in an individual patient depends on the systemic injury pattern, specific fracture pattern, and the ability to attain stable screw fixation.
Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro
2016-01-01
AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images, as compared to the reference magnetic resonance images. The difference in accuracy was statistically significant (P = 0.02). CONCLUSION: New generation CT scanner, using high resolution MPR images, represents a reliable diagnostic tool in assessment of loco-regional and whole body staging of advanced rectal cancer, especially in patients with MRI contraindications. PMID:27239115
Colonic polyps: application value of computer-aided detection in computed tomographic colonography.
Zhang, Hui-Mao; Guo, Wei; Liu, Gui-Feng; An, Dong-Hong; Gao, Shuo-Hui; Sun, Li-Bo; Yang, Hai-Shan
2011-02-01
Colonic polyps are frequently encountered in clinics. Computed tomographic colonography (CTC), as a painless and quick detection, has high values in clinics. In this study, we evaluated the application value of computer-aided detection (CAD) in CTC detection of colonic polyps in the Chinese population. CTC was performed with a GE 64-row multidetector computed tomography (MDCT) scanner. Data of 50 CTC patients (39 patients positive for at least one polyp of ≥ 0.5 cm in size and the other 11 patients negative by endoscopic detection) were retrospectively reviewed first without computer-aided detection (CAD) and then with CAD by four radiologists (two were experienced and another two inexperienced) blinded to colonoscopy findings. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of detected colonic polyps, as well as the areas under the ROC curves (Az value) with and without CAD were calculated. CAD increased the overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy of the colonic polyps detected by experienced and inexperienced readers. The sensitivity in detecting small polyps (5 - 9 mm) with CAD in experienced and inexperienced readers increased from 82% and 44% to 93% and 82%, respectively (P > 0.05 and P < 0.001). With the use of CAD, the overall false positive rate and false negative rate for the detection of polyps by experienced and inexperienced readers decreased in different degrees. Among 13 sessile polyps not detected by CAD, two were ≥ 1.0 cm, eleven were 5 - 9 mm in diameter, and nine were flat-shaped lesions. The application of CAD in combination with CTC can increase the ability to detect colonic polyps, particularly for inexperienced readers. However, CAD is of limited value for the detection of flat polyps.
Computer Instructional Aids for Undergraduate Control Education. 1978 Edition.
ERIC Educational Resources Information Center
Volz, Richard A.; And Others
This work represents the development of computer tools for undergraduate students. Emphasis is on automatic control theory using hybrid and digital computation. The routine calculations of control system analysis are presented as students would use them on the University of Michigan's central digital computer and the time-shared graphic terminals…
NASA Technical Reports Server (NTRS)
Orzechowski, J. A.
1982-01-01
The CMC fluid mechanics program system was developed to transmit the theoretical evolution of finite element numerical solution methodology, applied to nonlinear field problems into a versatile computer code for comprehensive flow field analysis. A detailed view of the code from the standpoint of a computer programmer's use is presented. A system macroflow chart and detailed flow charts of several routines necessary to interact with a theoretican/user to modify the operation of this program are presented. All subroutines and details of usage, primarily for input and output routines are described. Integer and real scalars and a cross reference list denoting subroutine usage for these scalars are outlined. Entry points in dynamic storage vector IZ; the lengths of each vector accompanying the scalar definitions are described. A listing of the routines peculiar to the standard test case and a listing of the input deck and printout for this case are included.
High-Speed, Low-Cost Workstation for Computation-Intensive Statistics. Phase 1
1990-06-20
routine implementation and performance. 5 The two compiled versions given in the table were coded in an attempt to obtain an optimized compiled version...level statistics and linear algebra routines (BSAS and BLAS) that have been prototyped in this study. For each routine, both the C code ( Turbo C...OISTRIBUTION /AVAILABILITY STATEMENT 12b. DISTRIBUTION CODE Unlimited distribution 13. ABSTRACT (Maximum 200 words) High-performance and low-cost
Radiological protection in computed tomography and cone beam computed tomography.
Rehani, M M
2015-06-01
The International Commission on Radiological Protection (ICRP) has sustained interest in radiological protection in computed tomography (CT), and ICRP Publications 87 and 102 focused on the management of patient doses in CT and multi-detector CT (MDCT) respectively. ICRP forecasted and 'sounded the alarm' on increasing patient doses in CT, and recommended actions for manufacturers and users. One of the approaches was that safety is best achieved when it is built into the machine, rather than left as a matter of choice for users. In view of upcoming challenges posed by newer systems that use cone beam geometry for CT (CBCT), and their widened usage, often by untrained users, a new ICRP task group has been working on radiological protection issues in CBCT. Some of the issues identified by the task group are: lack of standardisation of dosimetry in CBCT; the false belief within the medical and dental community that CBCT is a 'light', low-dose CT whereas mobile CBCT units and newer applications, particularly C-arm CT in interventional procedures, involve higher doses; lack of training in radiological protection among clinical users; and lack of dose information and tracking in many applications. This paper provides a summary of approaches used in CT and MDCT, and preliminary information regarding work just published for radiological protection in CBCT. © The International Society for Prosthetics and Orthotics Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Computer Programs (Turbomachinery)
NASA Technical Reports Server (NTRS)
1978-01-01
NASA computer programs are extensively used in design of industrial equipment. Available from the Computer Software Management and Information Center (COSMIC) at the University of Georgia, these programs are employed as analysis tools in design, test and development processes, providing savings in time and money. For example, two NASA computer programs are used daily in the design of turbomachinery by Delaval Turbine Division, Trenton, New Jersey. The company uses the NASA splint interpolation routine for analysis of turbine blade vibration and the performance of compressors and condensers. A second program, the NASA print plot routine, analyzes turbine rotor response and produces graphs for project reports. The photos show examples of Delaval test operations in which the computer programs play a part. In the large photo below, a 24-inch turbine blade is undergoing test; in the smaller photo, a steam turbine rotor is being prepared for stress measurements under actual operating conditions; the "spaghetti" is wiring for test instrumentation
Picco, P; Di Rocco, M; Buoncompagni, A; Gandullia, P; Lattere, M; Borrone, C
1991-01-01
A computerized program for children and adolescents with insulin dependent diabetes mellitus (IDDM) and their parents has been developed. Our program consists of computed assisted education, of aid to routine insulin dosage self adjustment and of records of home and hospital controls. Technically it has been implemented in DBIII plus: it runs on IBM PC computers (and compatible computers) and MS DOS (version 3.0 and later). Computed assisted education consists of 80 multiples choice questions divided in 2 parts: the first concerns basic informations about diabetes while the second one behavioral attitudes of patient in particular situations. Explanations are displayed after every question, apart from correct of incorrect choice. Help for self-adjustment of routine insulin dosage is offered in the third part. Finally daily home urine and/or blood controls and results of hospital admissions are stored in a database.
Design requirements for ubiquitous computing environments for healthcare professionals.
Bång, Magnus; Larsson, Anders; Eriksson, Henrik
2004-01-01
Ubiquitous computing environments can support clinical administrative routines in new ways. The aim of such computing approaches is to enhance routine physical work, thus it is important to identify specific design requirements. We studied healthcare professionals in an emergency room and developed the computer-augmented environment NOSTOS to support teamwork in that setting. NOSTOS uses digital pens and paper-based media as the primary input interface for data capture and as a means of controlling the system. NOSTOS also includes a digital desk, walk-up displays, and sensor technology that allow the system to track documents and activities in the workplace. We propose a set of requirements and discuss the value of tangible user interfaces for healthcare personnel. Our results suggest that the key requirements are flexibility in terms of system usage and seamless integration between digital and physical components. We also discuss how ubiquitous computing approaches like NOSTOS can be beneficial in the medical workplace.
A computer system for processing data from routine pulmonary function tests.
Pack, A I; McCusker, R; Moran, F
1977-01-01
In larger pulmonary function laboratories there is a need for computerised techniques of data processing. A flexible computer system, which is used routinely, is described. The system processes data from a relatively large range of tests. Two types of output are produced--one for laboratory purposes, and one for return to the referring physician. The system adds an automatic interpretative report for each set of results. In developing the interpretative system it has been necessary to utilise a number of arbitrary definitions. The present terminology for reporting pulmonary function tests has limitations. The computer interpretation system affords the opportunity to take account of known interaction between measurements of function and different pathological states. Images PMID:329462
Advanced Methodology for Simulation of Complex Flows Using Structured Grid Systems
NASA Technical Reports Server (NTRS)
Steinthorsson, Erlendur; Modiano, David
1995-01-01
Detailed simulations of viscous flows in complicated geometries pose a significant challenge to current capabilities of Computational Fluid Dynamics (CFD). To enable routine application of CFD to this class of problems, advanced methodologies are required that employ (a) automated grid generation, (b) adaptivity, (c) accurate discretizations and efficient solvers, and (d) advanced software techniques. Each of these ingredients contributes to increased accuracy, efficiency (in terms of human effort and computer time), and/or reliability of CFD software. In the long run, methodologies employing structured grid systems will remain a viable choice for routine simulation of flows in complex geometries only if genuinely automatic grid generation techniques for structured grids can be developed and if adaptivity is employed more routinely. More research in both these areas is urgently needed.
Data reduction programs for a laser radar system
NASA Technical Reports Server (NTRS)
Badavi, F. F.; Copeland, G. E.
1984-01-01
The listing and description of software routines which were used to analyze the analog data obtained from LIDAR - system are given. All routines are written in FORTRAN - IV on a HP - 1000/F minicomputer which serves as the heart of the data acquisition system for the LIDAR program. This particular system has 128 kilobytes of highspeed memory and is equipped with a Vector Instruction Set (VIS) firmware package, which is used in all the routines, to handle quick execution of different long loops. The system handles floating point arithmetic in hardware in order to enhance the speed of execution. This computer is a 2177 C/F series version of HP - 1000 RTE-IVB data acquisition computer system which is designed for real time data capture/analysis and disk/tape mass storage environment.
2015-04-12
Avoiding communication in the Lanczos bidiagonalization routine and associated Least Squares QR solver Erin Carson Electrical Engineering and...Bidiagonalization Routine and Associated Least Squares QR Solver 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d...throughout scienti c codes , are often the bottlenecks in application perfor- mance due to a low computation/communication ratio. In this paper we develop
Tonolini, Massimo
2016-01-01
Inguinal hernia repair (IHR) with prosthetic mesh implantation is the most common procedure in general surgery, and may be performed using either an open or laparoscopic approach. This paper provides an overview of contemporary tension-free IHR techniques and materials, and illustrates the expected postoperative imaging findings and iatrogenic injuries. Emphasis is placed on multidetector CT, which represents the ideal modality to comprehensively visualize the operated groin region and deeper intra-abdominal structures. CT consistently depicts seroma, mesh infections, hemorrhages, bowel complications and urinary bladder injuries, and thus generally provides a consistent basis for therapeutic choice. Since radiologists are increasingly requested to investigate suspected iatrogenic complications, this paper aims to provide an increased familiarity with early CT studies after IHR, including complications and normal postoperative appearances such as focal pseudolesions, in order to avoid misinterpretation and inappropriate management. PMID:27460285
NASA Astrophysics Data System (ADS)
Martorana, N. S.; Auditore, L.; Berceanu, I.; Cardella, G.; Chatterjee, M. B.; De Luca, S.; De Filippo, E.; Dell'Aquila, D.; Gnoffo, B.; Lanzalone, G.; Lombardo, I.; Maiolino, C.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Porto, F.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.
2017-11-01
We report on the results obtained by studying nuclear reactions between isotopes of Ca and Ti at 25 MeV/nucleon. We used the multidetector CHIMERA to detect charged reaction products. In particular, we studied two main effects: the isospin diffusion and the isospin drift. In order to study these processes we performed a moving-source analysis on kinetic energy spectra of the isobar nuclei ^{3H} and ^{3He} . This method allows to isolate the emission from the typical sources produced in reactions at Fermi energy: projectile like fragment (PLF), target like fragment (TLF), and mid-velocity (MV) emission. The obtained results are compared to previous experimental investigations and to simulations obtained with CoMD-II model.
Aubry, S; Pousse, A; Sarliève, P; Laborie, L; Delabrousse, E; Kastler, B
2006-11-01
To model vertebrae in 3D to improve radioanatomic knowledge of the spine with the vascular and nerve environment and simulate CT-guided interventions. Vertebra acquisitions were made with multidetector CT. We developed segmentation software and specific viewer software using the Delphi programming environment. This segmentation software makes it possible to model 3D high-resolution segments of vertebrae and their environment from multidetector CT acquisitions. Then the specific viewer software provides multiplanar reconstructions of the CT volume and the possibility to select different 3D objects of interest. This software package improves radiologists' radioanatomic knowledge through a new 3D anatomy presentation. Furthermore, the possibility of inserting virtual 3D objects in the volume can simulate CT-guided intervention. The first volumetric radioanatomic software has been born. Furthermore, it simulates CT-guided intervention and consequently has the potential to facilitate learning interventions using CT guidance.
Recent technologic advances in multi-detector row cardiac CT.
Halliburton, Sandra Simon
2009-11-01
Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.
Ohno, Takeshi; Araki, Fujio; Onizuka, Ryota; Hatemura, Masahiro; Shimonobou, Toshiaki; Sakamoto, Takashi; Okumura, Shuichiro; Ideguchi, Daichi; Honda, Keiichi; Kawata, Kenji
2017-03-01
This study compared dosimetric properties among four commercial multi-detector CT (MDCT) scanners. The X-ray beam characteristics were obtained from photon intensity attenuation curves of aluminum and off-center ratio (OCR) profiles in air, which were measured with four commercial MDCT scanners. The absorbed dose for MDCT scanners was evaluated with Farmer ionization chamber measurements at the center and four peripheral points in the body- and head-type cylindrical water phantoms. Measured collected charge was converted to absorbed dose using a 60 Co absorbed dose-to-water calibration factor and Monte Carlo (MC)-calculated correction factors. Four MDCT scanners were modeled to correspond with measured X-ray beam characteristics using GMctdospp (IMPS, Germany) software. Al half-value layers (Al-HVLs) with a body-bowtie filter determined from measured Al-attenuation curves ranged 7.2‒9.1mm at 120kVp and 6.1‒8.0mm at 100kVp. MC-calculated Al-HVLs and OCRs in air were in acceptable agreement within 0.5mm and 5% of measured values, respectively. The percentage difference between nominal and actual beam width was greater with decreasing collimation width. The absorbed doses for MDCT scanners at 120kVp ranged 5.1‒7.1mGy and 10.8‒17.5mGy per 100mAs at the center in the body- and head-type water phantoms, respectively. Measured doses at four peripheral points were within 5% agreement of MC-calculated values. The absorbed dose at the center in both water phantoms increased with decreasing Al-HVL for the same charge on the focus. In this study the X-ray beam characteristics and the absorbed dose were measured and compared with calculated values for four MDCT scanners. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Small-airway obstruction and emphysema in chronic obstructive pulmonary disease.
McDonough, John E; Yuan, Ren; Suzuki, Masaru; Seyednejad, Nazgol; Elliott, W Mark; Sanchez, Pablo G; Wright, Alexander C; Gefter, Warren B; Litzky, Leslie; Coxson, Harvey O; Paré, Peter D; Sin, Don D; Pierce, Richard A; Woods, Jason C; McWilliams, Annette M; Mayo, John R; Lam, Stephen C; Cooper, Joel D; Hogg, James C
2011-10-27
The major sites of obstruction in chronic obstructive pulmonary disease (COPD) are small airways (<2 mm in diameter). We wanted to determine whether there was a relationship between small-airway obstruction and emphysematous destruction in COPD. We used multidetector computed tomography (CT) to compare the number of airways measuring 2.0 to 2.5 mm in 78 patients who had various stages of COPD, as judged by scoring on the Global Initiative for Chronic Obstructive Lung Disease (GOLD) scale, in isolated lungs removed from patients with COPD who underwent lung transplantation, and in donor (control) lungs. MicroCT was used to measure the extent of emphysema (mean linear intercept), the number of terminal bronchioles per milliliter of lung volume, and the minimum diameters and cross-sectional areas of terminal bronchioles. On multidetector CT, in samples from patients with COPD, as compared with control samples, the number of airways measuring 2.0 to 2.5 mm in diameter was reduced in patients with GOLD stage 1 disease (P=0.001), GOLD stage 2 disease (P=0.02), and GOLD stage 3 or 4 disease (P<0.001). MicroCT of isolated samples of lungs removed from patients with GOLD stage 4 disease showed a reduction of 81 to 99.7% in the total cross-sectional area of terminal bronchioles and a reduction of 72 to 89% in the number of terminal bronchioles (P<0.001). A comparison of the number of terminal bronchioles and dimensions at different levels of emphysematous destruction (i.e., an increasing value for the mean linear intercept) showed that the narrowing and loss of terminal bronchioles preceded emphysematous destruction in COPD (P<0.001). These results show that narrowing and disappearance of small conducting airways before the onset of emphysematous destruction can explain the increased peripheral airway resistance reported in COPD. (Funded by the National Heart, Lung, and Blood Institute and others.).
Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D
2009-03-01
The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p < .001). There was no statistical significance for the renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.
Ateşoğlu, Sibel; Deniz, Mustafa; Uslu, Ayşe İmge
2018-01-18
Sternum is one of the skeleton parts which have frequently congenital anomalies and variations are commonly used by researchers in determining sex. We evaluated the morphological characteristics and sex-related changes of the sternum in adult individuals using multidetector CT in our study. 200 adults (103 female and 97 male) aged between 18-87 years were evaluated. Utilizing the morphological characteristics of the sternum based on the multi-slice images; length, width and the thickness of Manubrium, length, width and the thickness of Corpus Sterni, total length of Sternum, Sternal angle, Sternal index, length of the xiphoid process, the thickness of xiphoid process, the number of indents of xiphoid process were measured and a total of 20 parameters were evaluated by adding age, height and weight to these variables. The mean length of the manubrium, the length of corpus sterni, the length of total sternum, sternal index, sternal angle were found in females 46.7±5.1,86.6±9.7, 133.1±1.1, 54.47±10.0 and 163.75±5.79; in males 51.2±6, 102.4±13.3, 154.1±13.1, 50.11±10.02 and 162.21±6.17, respectively. We found that Hyrtl's law and Sternal index did not provide adequate accuracy for sex determination in our patients. It has been detected that the length of the Manubrium alone is not helpful for individual samples. Total length of the sternum was found to be more reliable than the length of the Manubrium and the length of corpus Sterni. We determined Sternal cleft and Sternal foramen as 0.5% and 3.5%, respectively. We suggest that the Morphometric standards cannot be universally applied and can demonstrate individual differences. The standard rules must be implemented for every population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohno, T; Araki, F
2015-06-15
Purpose: To compare dosimetric properties and patient organ doses from four commercial multidetector CT (MDCT) using Monte Carlo (MC) simulation based on the absorbed dose measured using a Farmer chamber and cylindrical water phantoms according to AAPM TG-111. Methods: Four commercial MDCT were modeled using the GMctdospp (IMPS, Germany) based on the EGSnrc user code. The incident photon spectrum and bowtie filter for MC simulations were determined so that calculated values of aluminum half-value layer (Al-HVL) and off-center ratio (OCR) profile in air agreed with measured values. The MC dose was calibrated from absorbed dose measurements using a Farmer chambermore » and cylindrical water phantoms. The dose distributions of head, chest, and abdominal scan were calculated using patient CT images and mean organ doses were evaluated from dose volume histograms. Results: The HVLs at 120 kVp of Brilliance, LightSpeed, Aquilion, and SOMATOM were 9.1, 7.5, 7.2, and 8.7 mm, respectively. The calculated Al-HVLs agreed with measurements within 0.3%. The calculated and measured OCR profiles agreed within 5%. For adult head scans, mean doses for eye lens from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.7, 38.5, 47.2 and 28.4 mGy, respectively. For chest scans, mean doses for lung from Brilliance, LightSpeed, Aquilion, and SOMATOM were 21.1, 26.1, 35.3 and 24.0 mGy, respectively. For adult abdominal scans, the mean doses for liver from Brilliance, LightSpeed, Aquilion, and SOMATOM were 16.5, 21.3, 22.7, and 18.0 mGy, respectively. The absorbed doses increased with decreasing Al-HVL. The organ doses from Aquilion were two greater than those from Brilliance in head scan. Conclusion: MC dose distributions based on absorbed dose measurement in cylindrical water phantom are useful to evaluate individual patient organ doses.« less
Slówko, Witold; Wiatrowski, Artur; Krysztof, Michał
2018-01-01
The paper considers some major problems of adapting the multi-detector method for three-dimensional (3D) imaging of wet bio-medical samples in Variable Pressure/Environmental Scanning Electron Microscope (VP/ESEM). The described method pertains to "single-view techniques", which to create the 3D surface model utilise a sequence of 2D SEM images captured from a single view point (along the electron beam axis) but illuminated from four directions. The basis of the method and requirements resulting from them are given for the detector systems of secondary (SE) and backscattered electrons (BSE), as well as designs of the systems which could work in variable conditions. The problems of SE detection with application of the Pressure Limiting Aperture (PLA) as the signal collector are discussed with respect to secondary electron backscattering by a gaseous environment. However, the authors' attention is turned mainly to the directional BSE detection, realized in two ways. The high take off angle BSE were captured through PLA with use of the quadruple semiconductor detector placed inside the intermediate chamber, while BSE starting at lower angles were detected by the four-folded ionization device working in the sample chamber environment. The latter relied on a conversion of highly energetic BSE into low energetic SE generated on walls and a gaseous environment of the deep discharge gap oriented along the BSE velocity direction. The converted BSE signal was amplified in an ionising avalanche developed in the electric field arranged transversally to the gap. The detector system operation is illustrated with numerous computer simulations and examples of experiments and 3D images. The latter were conducted in a JSM 840 microscope with its combined detector-vacuum equipment which could extend capabilities of this high vacuum instrument toward elevated pressures (over 1kPa) and environmental conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ho, Lisa M; Nelson, Rendon C; Delong, David M
2007-05-01
To prospectively evaluate the use of lean body weight (LBW) as the main determinant of the volume and rate of contrast material administration during multi-detector row computed tomography of the liver. This HIPAA-compliant study had institutional review board approval. All patients gave written informed consent. Four protocols were compared. Standard protocol involved 125 mL of iopamidol injected at 4 mL/sec. Total body weight (TBW) protocol involved 0.7 g iodine per kilogram of TBW. Calculated LBW and measured LBW protocols involved 0.86 g of iodine per kilogram and 0.92 g of iodine per kilogram calculated or measured LBW for men and women, respectively. Injection rate used for the three experimental protocols was determined proportionally on the basis of the calculated volume of contrast material. Postcontrast attenuation measurements during portal venous phase were obtained in liver, portal vein, and aorta for each group and were summed for each patient. Patient-to-patient enhancement variability in same group was measured with Levene test. Two-tailed t test was used to compare the three experimental protocols with the standard protocol. Data analysis was performed in 101 patients (25 or 26 patients per group), including 56 men and 45 women (mean age, 53 years). Average summed attenuation values for standard, TBW, calculated LBW, and measured LBW protocols were 419 HU +/- 50 (standard deviation), 443 HU +/- 51, 433 HU +/- 50, and 426 HU +/- 33, respectively (P = not significant for all). Levene test results for summed attenuation data for standard, TBW, calculated LBW, and measured LBW protocols were 40 +/- 29, 38 +/- 33 (P = .83), 35 +/- 35 (P = .56), and 26 +/- 19 (P = .05), respectively. By excluding highly variable but poorly perfused adipose tissue from calculation of contrast medium dose, the measured LBW protocol may lessen patient-to-patient enhancement variability while maintaining satisfactory hepatic and vascular enhancement.
45 CFR 310.1 - What definitions apply to this part?
Code of Federal Regulations, 2010 CFR
2010-10-01
... existing automated data processing computer system through an Intergovernmental Service Agreement; (4...) Office Automation means a generic adjunct component of a computer system that supports the routine... timely and satisfactory; (iv) Assurances that information in the computer system as well as access, use...
45 CFR 310.1 - What definitions apply to this part?
Code of Federal Regulations, 2013 CFR
2013-10-01
... existing automated data processing computer system through an Intergovernmental Service Agreement; (4...) Office Automation means a generic adjunct component of a computer system that supports the routine... timely and satisfactory; (iv) Assurances that information in the computer system as well as access, use...
45 CFR 310.1 - What definitions apply to this part?
Code of Federal Regulations, 2014 CFR
2014-10-01
... existing automated data processing computer system through an Intergovernmental Service Agreement; (4...) Office Automation means a generic adjunct component of a computer system that supports the routine... timely and satisfactory; (iv) Assurances that information in the computer system as well as access, use...
45 CFR 310.1 - What definitions apply to this part?
Code of Federal Regulations, 2011 CFR
2011-10-01
... existing automated data processing computer system through an Intergovernmental Service Agreement; (4...) Office Automation means a generic adjunct component of a computer system that supports the routine... timely and satisfactory; (iv) Assurances that information in the computer system as well as access, use...
45 CFR 310.1 - What definitions apply to this part?
Code of Federal Regulations, 2012 CFR
2012-10-01
... existing automated data processing computer system through an Intergovernmental Service Agreement; (4...) Office Automation means a generic adjunct component of a computer system that supports the routine... timely and satisfactory; (iv) Assurances that information in the computer system as well as access, use...
Feasibility of dual-energy computed tomography in radiation therapy planning
NASA Astrophysics Data System (ADS)
Sheen, Heesoon; Shin, Han-Back; Cho, Sungkoo; Cho, Junsang; Han, Youngyih
2017-12-01
In this study, the noise level, effective atomic number ( Z eff), accuracy of the computed tomography (CT) number, and the CT number to the relative electron density EDconversion curve were estimated for virtual monochromatic energy and polychromatic energy. These values were compared to the theoretically predicted values to investigate the feasibility of the use of dual-energy CT in routine radiation therapy planning. The accuracies of the parameters were within the range of acceptability. These results can serve as a stepping stone toward the routine use of dual-energy CT in radiotherapy planning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumann, K; Weber, U; Simeonov, Y
2015-06-15
Purpose: Aim of this study was to analyze the modulating, broadening effect on the Bragg Peak due to heterogeneous geometries like multi-wire chambers in the beam path of a particle therapy beam line. The effect was described by a mathematical model which was implemented in the Monte-Carlo code FLUKA via user-routines, in order to reduce the computation time for the simulations. Methods: The depth dose curve of 80 MeV/u C12-ions in a water phantom was calculated using the Monte-Carlo code FLUKA (reference curve). The modulating effect on this dose distribution behind eleven mesh-like foils (periodicity ∼80 microns) occurring in amore » typical set of multi-wire and dose chambers was mathematically described by optimizing a normal distribution so that the reverence curve convoluted with this distribution equals the modulated dose curve. This distribution describes a displacement in water and was transferred in a probability distribution of the thickness of the eleven foils using the water equivalent thickness of the foil’s material. From this distribution the distribution of the thickness of one foil was determined inversely. In FLUKA the heterogeneous foils were replaced by homogeneous foils and a user-routine was programmed that varies the thickness of the homogeneous foils for each simulated particle using this distribution. Results: Using the mathematical model and user-routine in FLUKA the broadening effect could be reproduced exactly when replacing the heterogeneous foils by homogeneous ones. The computation time was reduced by 90 percent. Conclusion: In this study the broadening effect on the Bragg Peak due to heterogeneous structures was analyzed, described by a mathematical model and implemented in FLUKA via user-routines. Applying these routines the computing time was reduced by 90 percent. The developed tool can be used for any heterogeneous structure in the dimensions of microns to millimeters, in principle even for organic materials like lung tissue.« less
Mathematical computer programs: A compilation
NASA Technical Reports Server (NTRS)
1972-01-01
Computer programs, routines, and subroutines for aiding engineers, scientists, and mathematicians in direct problem solving are presented. Also included is a group of items that affords the same users greater flexibility in the use of software.
Measuring Speed Using a Computer--Several Techniques.
ERIC Educational Resources Information Center
Pearce, Jon M.
1988-01-01
Introduces three different techniques to facilitate the measurement of speed and the associated kinematics and dynamics using a computer. Discusses sensing techniques using optical or ultrasonic sensors, interfacing with a computer, software routines for the interfaces, and other applications. Provides circuit diagrams, pictures, and a program to…
Computer Applications in Assessment and Counseling.
ERIC Educational Resources Information Center
Veldman, Donald J.; Menaker, Shirley L.
Public school counselors and psychologists can expect valuable assistance from computer-based assessment and counseling techniques within a few years, as programs now under development become generally available for the typical computers now used by schools for grade-reporting and class-scheduling. Although routine information-giving and gathering…
75 FR 32915 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-10
... used to authenticate authorized desktop and laptop computer users. Computer servers are scanned monthly... data is also used for management and statistical reports and studies. Routine uses of records... duties. The computer files are password protected with access restricted to authorized users. Records are...
Multiprocessor graphics computation and display using transputers
NASA Technical Reports Server (NTRS)
Ellis, Graham K.
1988-01-01
A package of two-dimensional graphics routines was developed to run on a transputer-based parallel processing system. These routines were designed to enable applications programmers to easily generate and display results from the transputer network in a graphic format. The graphics procedures were designed for the lowest possible network communication overhead for increased performance. The routines were designed for ease of use and to present an intuitive approach to generating graphics on the transputer parallel processing system.
Patient difficulty using tablet computers to screen in primary care.
Hess, Rachel; Santucci, Aimee; McTigue, Kathleen; Fischer, Gary; Kapoor, Wishwa
2008-04-01
Patient-administered computerized questionnaires represent a novel tool to assist primary care physicians in the delivery of preventive health care. The aim of this study was to assess patient-reported ease of use with a self-administered tablet computer-based questionnaire in routine clinical care. All patients seen in a university-based primary care practice were asked to provide routine screening information using a touch-screen tablet computer-based questionnaire. Patients reported difficulty using the tablet computer after completion of their first questionnaire. Ten thousand nine hundred ninety-nine patients completed the questionnaire between January 2004 and January 2006. We calculated rates of reporting difficulty (no difficulty, some difficulty, or a lot of difficulty) using the tablet computers based on patient age, sex, race, educational attainment, marital status, and number of comorbid medical conditions. We constructed multivariable ordered logistic models to identify predictors of increased self-reported difficulty using the computer. The majority of patients (84%) reported no difficulty using the tablet computers to complete the questionnaire, with only 3% reporting a lot of difficulty. Significant predictors of reporting more difficulty included increasing age [odds ratio (OR) 1.05, 95% confidence interval (CI) 1.05-1.05)]; Asian race (OR 2.3, 95% CI 1.8-2.9); African American race (OR 1.4, 95% CI 1.2-1.6); less than a high school education (OR 3.0, 95% CI 2.6-3.4); and the presence of comorbid medical conditions (1-2: OR 1.3, 95% CI 1.2-1.5; > or =3: OR 1.7 95% CI 1.5-2.1). The majority of primary care patients reported no difficulty using a self-administered tablet computer-based questionnaire. While computerized questionnaires present opportunities to collect routine screening information from patients, attention must be paid to vulnerable groups.
Computers in medicine: liability issues for physicians.
Hafner, A W; Filipowicz, A B; Whitely, W P
1989-07-01
Physicians routinely use computers to store, access, and retrieve medical information. As computer use becomes even more widespread in medicine, failure to utilize information systems may be seen as a violation of professional custom and lead to findings of professional liability. Even when a technology is not widespread, failure to incorporate it into medical practice may give rise to liability if the technology is accessible to the physician and reduces risk to the patient. Improvement in the availability of medical information sources imposes a greater burden on the physician to keep current and to obtain informed consent from patients. To routinely perform computer-assisted literature searches for informed consent and diagnosis is 'good medicine'. Clinical and diagnostic applications of computer technology now include computer-assisted decision making with the aid of sophisticated databases. Although such systems will expand the knowledge base and competence of physicians, malfunctioning software raises a major liability question. Also, complex computer-driven technology is used in direct patient care. Defective or improperly used hardware or software can lead to patient injury, thus raising additional complicated questions of professional liability and product liability.
Review and analysis of dense linear system solver package for distributed memory machines
NASA Technical Reports Server (NTRS)
Narang, H. N.
1993-01-01
A dense linear system solver package recently developed at the University of Texas at Austin for distributed memory machine (e.g. Intel Paragon) has been reviewed and analyzed. The package contains about 45 software routines, some written in FORTRAN, and some in C-language, and forms the basis for parallel/distributed solutions of systems of linear equations encountered in many problems of scientific and engineering nature. The package, being studied by the Computer Applications Branch of the Analysis and Computation Division, may provide a significant computational resource for NASA scientists and engineers in parallel/distributed computing. Since the package is new and not well tested or documented, many of its underlying concepts and implementations were unclear; our task was to review, analyze, and critique the package as a step in the process that will enable scientists and engineers to apply it to the solution of their problems. All routines in the package were reviewed and analyzed. Underlying theory or concepts which exist in the form of published papers or technical reports, or memos, were either obtained from the author, or from the scientific literature; and general algorithms, explanations, examples, and critiques have been provided to explain the workings of these programs. Wherever the things were still unclear, communications were made with the developer (author), either by telephone or by electronic mail, to understand the workings of the routines. Whenever possible, tests were made to verify the concepts and logic employed in their implementations. A detailed report is being separately documented to explain the workings of these routines.
NASA Technical Reports Server (NTRS)
Ahmadian, M.; Inman, D. J.
1982-01-01
Systems described by the matrix differental equation are considered. An interactive design routine is presented for positive definite mass, damping, and stiffness matrices. Designing is accomplished by adjusting the mass, damping, and stiffness matrices to obtain a desired oscillation behavior. The algorithm also features interactively modifying the physical structure of the system, obtaining the matrix structure and a number of other system properties. In case of a general system, where the M, C, and K matrices lack any special properties, a routine for the eigenproblem solution of the system is developed. The latent roots are obtained by computing the characteristic polynomial of the system and solving for its roots. The above routines are prepared in FORTRAN IV and prove to be usable for the machines with low core memory.
Routine human-competitive machine intelligence by means of genetic programming
NASA Astrophysics Data System (ADS)
Koza, John R.; Streeter, Matthew J.; Keane, Martin
2004-01-01
Genetic programming is a systematic method for getting computers to automatically solve a problem. Genetic programming starts from a high-level statement of what needs to be done and automatically creates a computer program to solve the problem. The paper demonstrates that genetic programming (1) now routinely delivers high-return human-competitive machine intelligence; (2) is an automated invention machine; (3) can automatically create a general solution to a problem in the form of a parameterized topology; and (4) has delivered a progression of qualitatively more substantial results in synchrony with five approximately order-of-magnitude increases in the expenditure of computer time. Recent results involving the automatic synthesis of the topology and sizing of analog electrical circuits and controllers demonstrate these points.
A Strassen-Newton algorithm for high-speed parallelizable matrix inversion
NASA Technical Reports Server (NTRS)
Bailey, David H.; Ferguson, Helaman R. P.
1988-01-01
Techniques are described for computing matrix inverses by algorithms that are highly suited to massively parallel computation. The techniques are based on an algorithm suggested by Strassen (1969). Variations of this scheme use matrix Newton iterations and other methods to improve the numerical stability while at the same time preserving a very high level of parallelism. One-processor Cray-2 implementations of these schemes range from one that is up to 55 percent faster than a conventional library routine to one that is slower than a library routine but achieves excellent numerical stability. The problem of computing the solution to a single set of linear equations is discussed, and it is shown that this problem can also be solved efficiently using these techniques.
Dysphagia lusorium in elderly: A case report
Kantarceken, Bulent; Bulbuloglu, Ertan; Yuksel, Murvet; Cetinkaya, Ali
2004-01-01
AIM: Late unset of dysphagia due to vascular abnormalities is a rare condition. We aimed to present a case of right subclavian artery abnormalities caused dysphagia in the elderly. METHODS: A 68-year-old female was admitted with dysphagia seven months ago. Upper endoscopic procedures and routine examinations could not demonstrate any etiology. Multislice computed thorax tomography was performed for probable extra- esophagial lesions. RESULTS: Multislice computed thorax tomography showed right subclavian artery abnormality and esophagial compression with this aberrant artery. CONCLUSION: Causes of dysphagia in the elderly are commonly malignancies, strictures and/or motility disorders. If routine examinations and endoscopic procedures fail to show any etiology, rare vascular abnormalities can be considered in such patients. Multislice computed tomography is a usefull choice in such conditions. PMID:15285045
Computer Series, 114: MO Theory Made Visible.
ERIC Educational Resources Information Center
Mealli, Carlo; Proserpio, Davide M.
1990-01-01
A collection of Molecular Orbital (MO) programs that have been integrated into routines and programs to illustrate MO theory are presented. Included are discussions of Computer Aided Composition of Atomic Orbitals (CACAO) and Walsh diagrams. (CW)
Huang, Chih-Hao; Brunsvold, Michael A
2006-01-01
Maxillary sinusitis may develop from the extension of periodontal disease. In this case, reconstructed three-dimensional images from multidetector spiral computed tomographs were helpful in evaluating periodontal bony defects and their relationship with the maxillary sinus. A 42-year-old woman in good general health presented with a chronic deep periodontal pocket on the palatal and interproximal aspects of tooth #14. Probing depths of the tooth ranged from 2 to 9 mm, and it exhibited a Class 1 mobility. Radiographs revealed a close relationship between the root apex and the maxillary sinus. The patient's periodontal diagnosis was localized severe chronic periodontitis. Treatment of the tooth consisted of cause-related therapy, surgical exploration, and bone grafting. A very deep circumferential bony defect at the palatal root of tooth #14 was noted during surgery. After the operation, the wound healed without incidence, but 10 days later, a maxillary sinusitis and periapical abscess developed. To control the infection, an evaluation of sinus and alveolus using computed tomographs was performed, systemic antibiotics were prescribed, and endodontic treatment was initiated. Two weeks after surgical treatment, the infection was relieved with the help of antibiotics and endodontic treatment. Bilateral bony communications between the maxillary sinus and periodontal bony defect of maxillary first molars were shown on three-dimensional computed tomographs. The digitally reconstructed images added valuable information for evaluating the periodontal defects. Three-dimensional images from spiral computed tomographs (CT) aided in evaluating and treating the close relationship between maxillary sinus disease and adjacent periodontal defects.
Sakakibara, Shunsuke; Onishi, Hiroyuki; Hashikawa, Kazunobu; Akashi, Masaya; Sakakibara, Akiko; Nomura, Tadashi; Terashi, Hiroto
2015-05-01
Most free flap reconstruction complications involve vascular compromise. Evaluation of vascular anatomy provides considerable information that can potentially minimize these complications. Previous reports have shown that contrast-enhanced computed tomography is effective for understanding three-dimensional arterial anatomy. However, most vascular complications result from venous thromboses, making imaging of venous anatomy highly desirable. The phase-lag computed tomography angiography (pl-CTA) technique involves 64-channel (virtually, 128-channel) multidetector CT and is used to acquire arterial images using conventional CTA. Venous images are three-dimensionally reconstructed using a subtraction technique involving combined venous phase and arterial phase images, using a computer workstation. This technique was used to examine 48 patients (12 lower leg reconstructions, 34 head and neck reconstructions, and 2 upper extremity reconstructions) without complications. The pl-CTA technique can be used for three-dimensional visualization of peripheral veins measuring approximately 1 mm in diameter. The pl-CTA information was especially helpful for secondary free flap reconstructions in the head and neck region after malignant tumor recurrence. In such cases, radical dissection of the neck was performed as part of the first operation, and many vessels, including veins, were resected and used in the first free-tissue transfer. The pl-CTA images also allowed visualization of varicose changes in the lower leg region and helped us avoid selecting those vessels for anastomosis. Thus, the pl-CTA-derived venous anatomy information was useful for exact evaluations during the planning of free-tissue transfers. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Context as Support for Learning Computer Organization
ERIC Educational Resources Information Center
Tew, Allison Elliott; Dorn, Brian; Leahy, William D., Jr.; Guzdial, Mark
2008-01-01
The ubiquity of personal computational devices in the lives of today's students presents a meaningful context for courses in computer organization beyond the general-purpose or imaginary processors routinely used. This article presents results of a comparative study examining student performance in a conventional organization course and in one…
The Routine Fitting of Kinetic Data to Models
Berman, Mones; Shahn, Ezra; Weiss, Marjory F.
1962-01-01
A mathematical formalism is presented for use with digital computers to permit the routine fitting of data to physical and mathematical models. Given a set of data, the mathematical equations describing a model, initial conditions for an experiment, and initial estimates for the values of model parameters, the computer program automatically proceeds to obtain a least squares fit of the data by an iterative adjustment of the values of the parameters. When the experimental measures are linear combinations of functions, the linear coefficients for a least squares fit may also be calculated. The values of both the parameters of the model and the coefficients for the sum of functions may be unknown independent variables, unknown dependent variables, or known constants. In the case of dependence, only linear dependencies are provided for in routine use. The computer program includes a number of subroutines, each one of which performs a special task. This permits flexibility in choosing various types of solutions and procedures. One subroutine, for example, handles linear differential equations, another, special non-linear functions, etc. The use of analytic or numerical solutions of equations is possible. PMID:13867975
A generalized chemistry version of SPARK
NASA Technical Reports Server (NTRS)
Carpenter, Mark H.
1988-01-01
An extension of the reacting H2-air computer code SPARK is presented, which enables the code to be used on any reacting flow problem. Routines are developed calculating in a general fashion, the reaction rates, and chemical Jacobians of any reacting system. In addition, an equilibrium routine is added so that the code will have frozen, finite rate, and equilibrium capabilities. The reaction rate for the species is determined from the law of mass action using Arrhenius expressions for the rate constants. The Jacobian routines are determined by numerically or analytically differentiating the law of mass action for each species. The equilibrium routine is based on a Gibbs free energy minimization routine. The routines are written in FORTRAN 77, with special consideration given to vectorization. Run times for the generalized routines are generally 20 percent slower than reaction specific routines. The numerical efficiency of the generalized analytical Jacobian, however, is nearly 300 percent better than the reaction specific numerical Jacobian used in SPARK.
Liebl, Hans; Garcia, Eduardo Grande; Holzner, Fabian; Noel, Peter B.; Burgkart, Rainer; Rummeny, Ernst J.; Baum, Thomas; Bauer, Jan S.
2015-01-01
Purpose To experimentally validate a non-linear finite element analysis (FEA) modeling approach assessing in-vitro fracture risk at the proximal femur and to transfer the method to standard in-vivo multi-detector computed tomography (MDCT) data of the hip aiming to predict additional hip fracture risk in subjects with and without osteoporosis associated vertebral fractures using bone mineral density (BMD) measurements as gold standard. Methods One fresh-frozen human femur specimen was mechanically tested and fractured simulating stance and clinically relevant fall loading configurations to the hip. After experimental in-vitro validation, the FEA simulation protocol was transferred to standard contrast-enhanced in-vivo MDCT images to calculate individual hip fracture risk each for 4 subjects with and without a history of osteoporotic vertebral fractures matched by age and gender. In addition, FEA based risk factor calculations were compared to manual femoral BMD measurements of all subjects. Results In-vitro simulations showed good correlation with the experimentally measured strains both in stance (R2 = 0.963) and fall configuration (R2 = 0.976). The simulated maximum stress overestimated the experimental failure load (4743 N) by 14.7% (5440 N) while the simulated maximum strain overestimated by 4.7% (4968 N). The simulated failed elements coincided precisely with the experimentally determined fracture locations. BMD measurements in subjects with a history of osteoporotic vertebral fractures did not differ significantly from subjects without fragility fractures (femoral head: p = 0.989; femoral neck: p = 0.366), but showed higher FEA based risk factors for additional incident hip fractures (p = 0.028). Conclusion FEA simulations were successfully validated by elastic and destructive in-vitro experiments. In the subsequent in-vivo analyses, MDCT based FEA based risk factor differences for additional hip fractures were not mirrored by according BMD measurements. Our data suggests, that MDCT derived FEA models may assess bone strength more accurately than BMD measurements alone, providing a valuable in-vivo fracture risk assessment tool. PMID:25723187
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Wen, E-mail: wenzhangxiao@126.com; Yan, Zhiping, E-mail: Yan.zhiping@zs-hospital.sh.cn; Luo, Jianjun, E-mail: luo.jianjun@zs-hospital.sh.cn
Objective: The purpose of this study was to establish an animal model of implanted inferior vena cava tumor thrombus (IVCTT) and to evaluate the effect of linear iodine-125 seeds strand in treating implanted IVCTT. Methods: Tumor cell line VX{sub 2} was inoculated subcutaneously into New Zealand rabbit to develop the parent tumor. The tumor strip was inoculated into inferior vena cava (IVC) to establish the IVCTT model. The IVCTT was confirmed by multidetector computed tomography (MDCT) after 2 weeks. Twelve rabbits with IVCTT were randomly divided into two groups. Treatment group (group T; n = 6) underwent Iodine-125 seeds brachytherapy,more » and the control group (group C; n = 6) underwent blank seeds strand. The blood laboratory examination (including blood routine examination, hepatic and renal function), body weight, survival time, and IVCTT volume by MDCT were monitored. All rabbits were dissected postmortem, and the therapeutic effects were evaluated on the basis of histopathology. The proliferating cell nuclear antigen index (PI) and apoptosis index (AI) of IVCTT were compared between two groups. T test, Wilcoxon rank test, and Kaplan-Meier survival curve analysis were used. Results: The success rate of establishing IVCTT was 100 %. The body weight loss and cachexia of rabbits in group C appeared earlier than in group T. Body weight in the third week, the mean survival time, PI, AI in groups T and C were 2.23 {+-} 0.12 kg, 57.83 {+-} 8.68 days, (16.73 {+-} 5.18 %), (29.47 {+-} 7.18 %), and 2.03 {+-} 0.13 kg, 43.67 {+-} 5.28 days, (63.01 {+-} 2.01 %), (6.02 {+-} 2.93 %), respectively. There were statistically significant differences between group T and group C (P < 0.05). The IVCTT volume of group T was remarkably smaller than that of group C. Conclusions: Injecting and suspensory fixing VX2 tumor strip into IVC is a reliable method to establish IVCTT animal model. The linear Iodine-125 seeds strand brachytherapy was a safe and effective method for treating IVCTT in rabbit model.« less
Cho, Jung Hwan; Lee, Da Young; Lee, Eun Seo; Kim, Jihyun; Park, Se Eun; Park, Cheol-Young; Lee, Won-Young; Oh, Ki-Won; Park, Sung-Woo; Rhee, Eun-Jung
2016-11-01
Results from previous studies support the association of lipoprotein(a) [Lp(a)] levels and coronary artery disease risk. In this study, we analyzed the association between baseline Lp(a) levels and future progression of coronary artery calcification (CAC) in apparently healthy Korean adults. A total of 2611 participants (mean age: 41years, 92% mend) who underwent a routine health check-up in 2010 and 2014 were enrolled. Coronary artery calcium score (CACS) were measured by multi-detector computed tomography. Baseline Lp(a) was measured by high-sensitivity immunoturbidimetric assay. Progression of CAC was defined as a change in CACS >0 over four years. Bivariate correlation analyses with baseline Lp(a) and other metabolic parameters revealed age, total cholesterol, HDL-C, LDL-C and CACS to have a significant positive correlation, while body weight, fasting glucose level, blood pressure and triglyceride level were negatively correlated with baseline Lp(a) level. After four years of follow-up, 635 subjects (24.3%) had CAC progression. The participants who had CAC progression were older, composed of more men, more obese, and had higher fasting glucose levels and worse baseline lipid profiles compared to those who did not have CAC progression. The mean serum Lp(a) level was significantly higher in subjects who had CAC progression compared to those who did not (32.5 vs. 28.9mg/dL, p<0.01). When the risk for CAC progression according to baseline Lp(a) was calculated, those with Lp(a) level≥50mg/dL had an odds ratio of 1.333 (95% CI 1.027-1.730) for CAC progression compared to those with Lp(a)<50mg/dL after adjusting for confounding factors. In this study, the subjects who had higher Lp(a) were at significantly higher risk for CAC progression after four years of follow-up, suggesting the role of high Lp(a) in CAC progression. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Positron Scanner for Brain Tumors
DOE R&D Accomplishments Database
Robertson, J. S.; Bozzo, S. R.
1964-10-09
It was thought that if a multi-detector device could be developed, the scanning time would be greatly shortened, with such consequent advantages as being able to work with lower dose of radiation, to obtain serial determinations, and to work with shorter-lived isotopes.
Soft Real-Time PID Control on a VME Computer
NASA Technical Reports Server (NTRS)
Karayan, Vahag; Sander, Stanley; Cageao, Richard
2007-01-01
microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.
ERIC Educational Resources Information Center
Sawbridge, Jenny L.; Qureshi, Haseeb K.; Boyd, Matthew J.; Brown, Angus M.
2014-01-01
The ability to understand and implement calculations required for molarity and dilution computations that are routinely undertaken in the laboratory are essential skills that should be possessed by all students entering an undergraduate Life Sciences degree. However, it is increasingly recognized that the majority of these students are ill…
“Kicking the Tires” of the energy balance routine within the CROPGRO crop growth models of DSSAT
USDA-ARS?s Scientific Manuscript database
Two decades ago a routine called ETPHOT was written to compute evaporation, transpiration, and photosynthesis in the CROPGRO crop simulation programs for grain legumes such as soybean. These programs are part of the DSSAT (Decision Support System of Agrotechnology Transfer), which has been widely us...
APPLIED RESEARCH ON IMPLEMENTATION AND USE OF LIST PROCESSING LANGUAGES
powerful manipulation of symbolic text (TECO), and (5) specification of a set of generalized display routines for visual communication with the computer. All work done related to the M-460 research computer at AFCRL.
Computing Lives And Reliabilities Of Turboprop Transmissions
NASA Technical Reports Server (NTRS)
Coy, J. J.; Savage, M.; Radil, K. C.; Lewicki, D. G.
1991-01-01
Computer program PSHFT calculates lifetimes of variety of aircraft transmissions. Consists of main program, series of subroutines applying to specific configurations, generic subroutines for analysis of properties of components, subroutines for analysis of system, and common block. Main program selects routines used in analysis and causes them to operate in desired sequence. Series of configuration-specific subroutines put in configuration data, perform force and life analyses for components (with help of generic component-property-analysis subroutines), fill property array, call up system-analysis routines, and finally print out results of analysis for system and components. Written in FORTRAN 77(IV).
Equipment for linking the AutoAnalyzer on-line to a computer
Simpson, D.; Sims, G. E.; Harrison, M. I.; Whitby, L. G.
1971-01-01
An Elliott 903 computer with 8K central core store and magnetic tape backing store has been operated for approximately 20 months in a clinical chemistry laboratory. Details of the equipment designed for linking AutoAnalyzers on-line to the computer are described, and data presented concerning the time required by the computer for different processes. The reliability of the various components in daily operation is discussed. Limitations in the system's capabilities have been defined, and ways of overcoming these are delineated. At present, routine operations include the preparation of worksheets for a limited range of tests (five channels), monitoring of up to 11 AutoAnalyzer channels at a time on a seven-day week basis (with process control and automatic calculation of results), and the provision of quality control data. Cumulative reports can be printed out on those analyses for which computer-prepared worksheets are provided but the system will require extension before these can be issued sufficiently rapidly for routine use. PMID:5551384
ERIC Educational Resources Information Center
Weller, Herman G.; Hartson, H. Rex
1992-01-01
Describes human-computer interface needs for empowering environments in computer usage in which the machine handles the routine mechanics of problem solving while the user concentrates on its higher order meanings. A closed-loop model of interaction is described, interface as illusion is discussed, and metaphors for human-computer interaction are…
Lancellotti, Patrizio; Pibarot, Philippe; Chambers, John; Edvardsen, Thor; Delgado, Victoria; Dulgheru, Raluca; Pepi, Mauro; Cosyns, Bernard; Dweck, Mark R; Garbi, Madalina; Magne, Julien; Nieman, Koen; Rosenhek, Raphael; Bernard, Anne; Lowenstein, Jorge; Vieira, Marcelo Luiz Campos; Rabischoffsky, Arnaldo; Vyhmeister, Rodrigo Hernández; Zhou, Xiao; Zhang, Yun; Zamorano, Jose-Luis; Habib, Gilbert
2016-06-01
Prosthetic heart valve (PHV) dysfunction is rare but potentially life-threatening. Although often challenging, establishing the exact cause of PHV dysfunction is essential to determine the appropriate treatment strategy. In clinical practice, a comprehensive approach that integrates several parameters of valve morphology and function assessed with 2D/3D transthoracic and transoesophageal echocardiography is a key to appropriately detect and quantitate PHV dysfunction. Cinefluoroscopy, multidetector computed tomography, cardiac magnetic resonance imaging, and to a lesser extent, nuclear imaging are complementary tools for the diagnosis and management of PHV complications. The present document provides recommendations for the use of multimodality imaging in the assessment of PHVs. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
Meenan, Christopher; Daly, Barry; Toland, Christopher; Nagy, Paul
2006-01-01
Rapid advances are changing the technology and applications of multidetector computed tomography (CT) scanners. The major increase in data associated with this new technology, however, breaks most commercial picture archiving and communication system (PACS) architectures by preventing them from delivering data in real time to radiologists and outside clinicians. We proposed a phased model for 3D workflow, installed a thin-slice archive and measured thin-slice data storage over a period of 5 months. A mean of 1,869 CT studies were stored per month, with an average of 643 images per study and a mean total volume of 588 GB/month. We also surveyed 48 radiologists to determine diagnostic use, impressions of thin-slice value, and requirements for retention times. The majority of radiologists thought thin slice was helpful for diagnosis and regularly used the application. Permanent storage of thin slice CT is likely to become best practice and a mission-critical pursuit for the health care enterprise.
Embolization of traumatic and non-traumatic peripheral vascular lesions with Onyx.
Regine, Renato; Palmieri, Francesco; De Siero, Michele; Rescigno, Antonio; Sica, Vincenzo; Cantarela, Raffaele; Villari, Vincenzo
2015-03-01
The aim of our study is to verify the feasibility and the efficacy of Onyx as embolization agent in the treatment of traumatic and non-traumatic peripheral vascular lesions. In the period between September 2006 and March 2012, we treated with Onyx 26 patients (14 males/12 females; age range, 18-85 years old; mean age, 65 years old), 11 of which with traumatic peripheral vascular lesions and 15 with non-traumatic vascular lesions (9 neoplastic hemorrhagic lesions, 3 arteriovenous malformations (AVMs) and 3 aneurysms). Follow-up controls were performed with clinical examination and by multidetector computed tomography (MDCT) imaging 1, 6, and 12 months after the procedure. All peripheral vascular lesions were embolized with Onyx; 3 patients with aneurysms were treated with Onyx associated with endovascular coils. Four elective and 22 emergency embolization procedures were performed. In all patients, we obtained cessation of bleeding and the complete and permanent embolization of all vascular lesions. Onyx is an effective and safe embolization agent for peripheral vascular lesions.
The Abernethy malformation-myriad imaging manifestations of a single entity.
Ghuman, Samarjit S; Gupta, Saumya; Buxi, T B S; Rawat, Kishan S; Yadav, Anurag; Mehta, Naimish; Sud, Seema
2016-01-01
Abernethy malformation, also known as congenital extrahepatic portosystemic shunts (CEPS) is a rare clinical entity and manifests with different clinical symptoms. CEPS are abnormalities of vascular development where there is shunting of portal blood into the systemic venous system. Multidetector computed tomography (MDCT) is a fast and effective modality for evaluation of CEPS. CT displays all the information desired by the surgeon as well as the clinician including the anatomy of the splenic and superior mesenteric veins, size and site of the shunt, presence or absence of the portal vein radicles, and helps to plan the therapy and even the follow-up of these patients. Contrast-enhanced magnetic resonance imaging (MRI) has also emerged as a promising tool for the evaluation of liver lesions associated with the malformation. The Radiologist should be aware of the various imaging appearances of this entity including its complications. In this article, we describe the imaging appearances of CEPS, their complications, and their imaging appearances on CT and MRI. We have also described various associated anomalies.
Cardiac veins: collateral venous drainage pathways in chronic hemodialysis patients.
Ozmen, Evrim; Algin, Oktay
2016-07-12
Venous anomalies are diagnostic and therapeutic challenges. Subclavian or superior vena cava stenosis can be developed and venous return can be achieved via cardiac veins and coronary sinus in patients with central venous catheter for long-term hemodialysis. These types of abnormalities are not extremely rare especially in patients with a history of central venous catheter placement. Detection of these anomalies and subclavian vein stenosis before the surgical creation of hemodialysis fistulae or tunneled central venous catheter placement may prevent unnecessary interventions in those patients. Multidetector computed tomography (MDCT) technique can give further information when compared with fluoroscopy or digital subtraction angiography in the management of these patients. This case report describes interesting aspects of central vein complications in hemodialysis patients. As a conclusion, there are limited data about thoracic venous return, and further prospective studies with large patient number are required. MDCT with 3D reconstruction is particularly useful for the accurate evaluation of venous patency, variations, and collateral circulation. Also it is an excellent tool for choosing and planning treatment.
Goeree, Ron; Blackhouse, Gord; Bowen, James M; O'Reilly, Daria; Sutherland, Simone; Hopkins, Robert; Chow, Benjamin; Freeman, Michael; Provost, Yves; Dennie, Carole; Cohen, Eric; Marcuzzi, Dan; Iwanochko, Robert; Moody, Alan; Paul, Narinder; Parker, John D
2013-10-01
Conventional coronary angiography (CCA) is the standard diagnostic for coronary artery disease (CAD), but multi-detector computed tomography coronary angiography (CTCA) is a non-invasive alternative. A multi-center coverage with evidence development study was undertaken and combined with an economic model to estimate the cost-effectiveness of CTCA followed by CCA vs CCA alone. Alternative assumptions were tested in patient scenario and sensitivity analyses. CCA was found to dominate CTCA, however, CTCA was relatively more cost-effective in females, in advancing age, in patients with lower pre-test probabilities of CAD, the higher the sensitivity of CTCA and the lower the probability of undergoing a confirmatory CCA following a positive CTCA. RESULTS were very sensitive to alternative patient populations and modeling assumptions. Careful consideration of patient characteristics, procedures to improve the diagnostic yield of CTCA and selective use of CCA following CTCA will impact whether CTCA is cost-effective or dominates CCA.
[Preoperative imaging/operation planning for liver surgery].
Schoening, W N; Denecke, T; Neumann, U P
2015-12-01
The currently established standard for planning liver surgery is multistage contrast media-enhanced multidetector computed tomography (CM-CT), which as a rule enables an appropriate resection planning, e.g. a precise identification and localization of primary and secondary liver tumors as well as the anatomical relation to extrahepatic and/or intrahepatic vascular and biliary structures. Furthermore, CM-CT enables the measurement of tumor volume, total liver volume and residual liver volume after resection. Under the condition of normal liver function a residual liver volume of 25 % is nowadays considered sufficient and safe. Recent studies in patients with liver metastases of colorectal cancer showed a clear staging advantage of contrast media-enhanced magnetic resonance imaging (CM-MRI) versus CM-CT. In addition, most recent data showed that the use of liver-specific MRI contrast media further increases the sensitivity and specificity of detection of liver metastases. This imaging technology seems to lead closer to the ideal "one stop shopping" diagnostic tool in preoperative planning of liver resection.
The Abernethy malformation—myriad imaging manifestations of a single entity
Ghuman, Samarjit S; Gupta, Saumya; Buxi, T B S; Rawat, Kishan S; Yadav, Anurag; Mehta, Naimish; Sud, Seema
2016-01-01
Abernethy malformation, also known as congenital extrahepatic portosystemic shunts (CEPS) is a rare clinical entity and manifests with different clinical symptoms. CEPS are abnormalities of vascular development where there is shunting of portal blood into the systemic venous system. Multidetector computed tomography (MDCT) is a fast and effective modality for evaluation of CEPS. CT displays all the information desired by the surgeon as well as the clinician including the anatomy of the splenic and superior mesenteric veins, size and site of the shunt, presence or absence of the portal vein radicles, and helps to plan the therapy and even the follow-up of these patients. Contrast-enhanced magnetic resonance imaging (MRI) has also emerged as a promising tool for the evaluation of liver lesions associated with the malformation. The Radiologist should be aware of the various imaging appearances of this entity including its complications. In this article, we describe the imaging appearances of CEPS, their complications, and their imaging appearances on CT and MRI. We have also described various associated anomalies. PMID:27857464
Computed tomography imaging and angiography - principles.
Kamalian, Shervin; Lev, Michael H; Gupta, Rajiv
2016-01-01
The evaluation of patients with diverse neurologic disorders was forever changed in the summer of 1973, when the first commercial computed tomography (CT) scanners were introduced. Until then, the detection and characterization of intracranial or spinal lesions could only be inferred by limited spatial resolution radioisotope scans, or by the patterns of tissue and vascular displacement on invasive pneumoencaphalography and direct carotid puncture catheter arteriography. Even the earliest-generation CT scanners - which required tens of minutes for the acquisition and reconstruction of low-resolution images (128×128 matrix) - could, based on density, noninvasively distinguish infarct, hemorrhage, and other mass lesions with unprecedented accuracy. Iodinated, intravenous contrast added further sensitivity and specificity in regions of blood-brain barrier breakdown. The advent of rapid multidetector row CT scanning in the early 1990s created renewed enthusiasm for CT, with CT angiography largely replacing direct catheter angiography. More recently, iterative reconstruction postprocessing techniques have made possible high spatial resolution, reduced noise, very low radiation dose CT scanning. The speed, spatial resolution, contrast resolution, and low radiation dose capability of present-day scanners have also facilitated dual-energy imaging which, like magnetic resonance imaging, for the first time, has allowed tissue-specific CT imaging characterization of intracranial pathology. © 2016 Elsevier B.V. All rights reserved.
Miller, Julie M; Dewey, Marc; Vavere, Andrea L; Rochitte, Carlos E; Niinuma, Hiroyuki; Arbab-Zadeh, Armin; Paul, Narinder; Hoe, John; de Roos, Albert; Yoshioka, Kunihiro; Lemos, Pedro A; Bush, David E; Lardo, Albert C; Texter, John; Brinker, Jeffery; Cox, Christopher; Clouse, Melvin E; Lima, João A C
2009-04-01
Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective "CORE-64" trial ("Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors"). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows.
Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito
2014-01-01
The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.
NASA Astrophysics Data System (ADS)
Fetita, C.; Chang-Chien, K. C.; Brillet, P. Y.; Pr"teux, F.; Chang, R. F.
2012-03-01
Our study aims at developing a computer-aided diagnosis (CAD) system for fully automatic detection and classification of pathological lung parenchyma patterns in idiopathic interstitial pneumonias (IIP) and emphysema using multi-detector computed tomography (MDCT). The proposed CAD system is based on three-dimensional (3-D) mathematical morphology, texture and fuzzy logic analysis, and can be divided into four stages: (1) a multi-resolution decomposition scheme based on a 3-D morphological filter was exploited to discriminate the lung region patterns at different analysis scales. (2) An additional spatial lung partitioning based on the lung tissue texture was introduced to reinforce the spatial separation between patterns extracted at the same resolution level in the decomposition pyramid. Then, (3) a hierarchic tree structure was exploited to describe the relationship between patterns at different resolution levels, and for each pattern, six fuzzy membership functions were established for assigning a probability of association with a normal tissue or a pathological target. Finally, (4) a decision step exploiting the fuzzy-logic assignments selects the target class of each lung pattern among the following categories: normal (N), emphysema (EM), fibrosis/honeycombing (FHC), and ground glass (GDG). According to a preliminary evaluation on an extended database, the proposed method can overcome the drawbacks of a previously developed approach and achieve higher sensitivity and specificity.
[Measurement of scatter radiation on MDCT equipment using an OSL dosimeter].
Tomita, Hironobu; Morozumi, Kunihiko
2004-11-01
The recent introduction of multi-detector row computed tomography (MDCT) has made it possible to scan the entire abdomen within approximately 10 sec in procedures such as interventional radiology computed tomography (IVRCT), which are associated with operator exposure. Therefore, anxious patients and patients who are not able to remain still can be examined with an assistant. In the present study, radiation exposure to the assistant was estimated, and the distribution of scattered radiation near the gantry was measured using an optically stimulated luminescence (OSL) dosimeter. Simultaneous measurements were obtained using a direction storage (DIS) dosimeter for reference. The maximum value of 1.47 mSv per examination was obtained at the point closest to the gantry's center (50 cm from the center at a height of 150 cm above the floor) . In addition, scattered radiation decreased as the measurement point was moved further from the gantry's center, falling below the limit of detection (0.1 mSv or less) at 200 cm and at the sides of the gantry. OSL dosimeters are also employed as personal dosimeters, permitting reliable values to be obtained easily. They were found to be an effective tool for the measurement of scattered radiation, as in the present study, helping to provide better understanding of the distribution of scattered radiation within the CT room.
Huang, Yu-Sen; Hsu, Hsao-Hsun; Chen, Jo-Yu; Tai, Mei-Hwa; Jaw, Fu-Shan; Chang, Yeun-Chung
2014-01-01
This study strived to evaluate the relationship between degree of pulmonary emphysema and cardiac ventricular function in chronic obstructive pulmonary disease (COPD) patients with pulmonary hypertension (PH) using electrocardiographic-gated multidetector computed tomography (CT). Lung transplantation candidates with the diagnosis of COPD and PH were chosen for the study population, and a total of 15 patients were included. The extent of emphysema is defined as the percentage of voxels below -910 Hounsfield units in the lung windows in whole lung CT without intravenous contrast. Heart function parameters were measured by electrocardiographic-gated CT angiography. Linear regression analysis was conducted to examine the associations between percent emphysema and heart function indicators. Significant correlations were found between percent emphysema and right ventricular (RV) measurements, including RV end-diastolic volume (R(2) = 0.340, p = 0.023), RV stroke volume (R(2) = 0.406, p = 0.011), and RV cardiac output (R(2) = 0.382, p = 0.014); the correlations between percent emphysema and left ventricular function indicators were not observed. The study revealed that percent emphysema is correlated with RV dysfunction among COPD patients with PH. Based on our findings, percent emphysema can be considered for use as an indicator to predict the severity of right ventricular dysfunction among COPD patients.
Dagvasumberel, Munkhbaatar; Shimabukuro, Michio; Nishiuchi, Takeshi; Ueno, Junji; Takao, Shoichiro; Fukuda, Daiju; Hirata, Yoichiro; Kurobe, Hirotsugu; Soeki, Takeshi; Iwase, Takashi; Kusunose, Kenya; Niki, Toshiyuki; Yamaguchi, Koji; Taketani, Yoshio; Yagi, Shusuke; Tomita, Noriko; Yamada, Hirotsugu; Wakatsuki, Tetsuzo; Harada, Masafumi; Kitagawa, Tetsuya; Sata, Masataka
2012-09-10
Growing evidence suggests that epicardial adipose tissue (EAT) may contribute to the development of coronary artery disease (CAD). In this study, we explored gender disparities in EAT volume (EATV) and its impact on coronary atherosclerosis. The study population consisted of 90 consecutive subjects (age: 63 ± 12 years; men: 47, women: 43) who underwent 256-slice multi-detector computed tomography (MDCT) coronary angiography. EATV was measured as the sum of cross-sectional epicardial fat area on CT images, from the lower surface of the left pulmonary artery origin to the apex. Subjects were segregated into the CAD group (coronary luminal narrowing > 50%) and non-CAD group. EATV/body surface area (BSA) was higher among men in the CAD group than in the non-CAD group (62 ± 13 vs. 33 ± 10 cm3/m2, p < 0.0001), but did not differ significantly among women in the 2 groups (49 ± 18 vs. 42 ± 9 cm3/m2, not significant). Multivariate logistic analysis showed that EATV/BSA was the single predictor for >50% coronary luminal narrowing in men (p < 0.0001). Predictors excluded were age, body mass index, hypertension, diabetes mellitus, and hyperlipidemia. Increased EATV is strongly associated with coronary atherosclerosis in men.
Pessis, Eric; Campagna, Raphaël; Sverzut, Jean-Michel; Bach, Fabienne; Rodallec, Mathieu; Guerini, Henri; Feydy, Antoine; Drapé, Jean-Luc
2013-01-01
With arthroplasty being increasingly used to relieve joint pain, imaging of patients with metal implants can represent a significant part of the clinical work load in the radiologist's daily practice. Computed tomography (CT) plays an important role in the postoperative evaluation of patients who are suspected of having metal prosthesis-related problems such as aseptic loosening, bone resorption or osteolysis, infection, dislocation, metal hardware failure, or periprosthetic bone fracture. Despite advances in detector technology and computer software, artifacts from metal implants can seriously degrade the quality of CT images, sometimes to the point of making them diagnostically unusable. Several factors may help reduce the number and severity of artifacts at multidetector CT, including decreasing the detector collimation and pitch, increasing the kilovolt peak and tube charge, and using appropriate reconstruction algorithms and section thickness. More recently, dual-energy CT has been proposed as a means of reducing beam-hardening artifacts. The use of dual-energy CT scanners allows the synthesis of virtual monochromatic spectral (VMS) images. Monochromatic images depict how the imaged object would look if the x-ray source produced x-ray photons at only a single energy level. For this reason, VMS imaging is expected to provide improved image quality by reducing beam-hardening artifacts.
Computed Tomography of the Normal Bovine Tarsus.
Hagag, U; Tawfiek, M; Brehm, W; Gerlach, K
2016-12-01
The objective of this study was to provide a detailed multiplanar computed tomographic (CT) anatomic reference for the bovine tarsus. The tarsal regions from twelve healthy adult cow cadavers were scanned in both soft and bone windows via a 16-slice multidetector CT scanner. Tarsi were frozen at -20 o C and sectioned to 10-mm-thick slices in transverse, dorsal and sagittal planes respecting the imaging protocol. The frozen sections were cleaned and then photographed. Anatomic structures were identified, labelled and compared with the corresponding CT images. The sagittal plane was indispensable for evaluation of bone contours, the dorsal plane was valuable in examination of the collateral ligaments, and both were beneficial for assessment of the tarsal joint articulations. CT images allowed excellent delineation between the cortex and medulla of bones, and the trabecular structure was clearly depicted. The tarsal soft tissues showed variable shades of grey, and the synovial fluid was the lowest attenuated structure. This study provided full assessment of the clinically relevant anatomic structures of the bovine tarsal joint. This technique may be of value when results from other diagnostic imaging techniques are indecisive. Images presented in this study should serve as a basic CT reference and assist in the interpretation of various bovine tarsal pathology. © 2016 Blackwell Verlag GmbH.
Bivariate normal, conditional and rectangular probabilities: A computer program with applications
NASA Technical Reports Server (NTRS)
Swaroop, R.; Brownlow, J. D.; Ashwworth, G. R.; Winter, W. R.
1980-01-01
Some results for the bivariate normal distribution analysis are presented. Computer programs for conditional normal probabilities, marginal probabilities, as well as joint probabilities for rectangular regions are given: routines for computing fractile points and distribution functions are also presented. Some examples from a closed circuit television experiment are included.
Optimal and Nonoptimal Computer-Based Test Designs for Making Pass-Fail Decisions
ERIC Educational Resources Information Center
Hambleton, Ronald K.; Xing, Dehui
2006-01-01
Now that many credentialing exams are being routinely administered by computer, new computer-based test designs, along with item response theory models, are being aggressively researched to identify specific designs that can increase the decision consistency and accuracy of pass-fail decisions. The purpose of this study was to investigate the…
A solar radiation model for use in climate studies
NASA Technical Reports Server (NTRS)
Chou, Ming-Dah
1992-01-01
A solar radiation routine is developed for use in climate studies that includes absorption and scattering due to ozone, water vapor, oxygen, carbon dioxide, clouds, and aerosols. Rayleigh scattering is also included. Broadband parameterization is used to compute the absorption by water vapor in a clear atmosphere, and the k-distribution method is applied to compute fluxes in a scattering atmosphere. The reflectivity and transmissivity of a scattering layer are computed analytically using the delta-four-stream discrete-ordinate approximation. The two-stream adding method is then applied to compute fluxes for a composite of clear and scattering layers. Compared to the results of high spectral resolution and detailed multiple-scattering calculations, fluxes and heating rate are accurately computed to within a few percent. The high accuracy of the flux and heating-rate calculations is achieved with a reasonable amount of computing time. With the UV and visible region grouped into four bands, this solar radiation routine is useful not only for climate studies but also for studies on photolysis in the upper atmosphere and photosynthesis in the biosphere.
Paradigm of pretest risk stratification before coronary computed tomography.
Jensen, Jesper Møller; Ovrehus, Kristian A; Nielsen, Lene H; Jensen, Jesper K; Larsen, Henrik M; Nørgaard, Bjarne L
2009-01-01
The optimal method of determining the pretest risk of coronary artery disease as a patient selection tool before coronary multidetector computed tomography (MDCT) is unknown. We investigated the ability of 3 different clinical risk scores to predict the outcome of coronary MDCT. This was a retrospective study of 551 patients consecutively referred for coronary MDCT on a suspicion of coronary artery disease. Diamond-Forrester, Duke, and Morise risk models were used to predict coronary artery stenosis (>50%) as assessed by coronary MDCT. The models were compared by receiver operating characteristic analysis. The distribution of low-, intermediate-, and high-risk persons, respectively, was established and compared for each of the 3 risk models. Overall, all risk prediction models performed equally well. However, the Duke risk model classified the low-risk patients more correctly than did the other models (P < 0.01). In patients without coronary artery calcification (CAC), the predictive value of the Duke risk model was superior to the other risk models (P < 0.05). Currently available risk prediction models seem to perform better in patients without CAC. Between the risk prediction models, there was a significant discrepancy in the distribution of patients at low, intermediate, or high risk (P < 0.01). The 3 risk prediction models perform equally well, although the Duke risk score may have advantages in subsets of patients. The choice of risk prediction model affects the referral pattern to MDCT. Copyright (c) 2009 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
[Imaging of diabetic osteopathy].
Patsch, J; Pietschmann, P; Schueller-Weidekamm, C
2015-04-01
Diabetic bone diseases are more than just osteoporosis in patients with diabetes mellitus (DM): a relatively high bone mineral density is paired with a paradoxically high risk of fragility fractures. Diabetics exhibit low bone turnover, osteocyte dysfunction, relative hypoparathyroidism and an accumulation of advanced glycation end products in the bone matrix. Besides typical insufficiency fractures, diabetics show a high risk for peripheral fractures of the lower extremities (e.g. metatarsal fractures). The correct interdisciplinary assessment of fracture risks in patients with DM is therefore a clinical challenge. There are two state of the art imaging methods for the quantification of fracture risks: dual energy X-ray absorptiometry (DXA) and quantitative computed tomography (QCT). Radiography, multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) are suitable for the detection of insufficiency fractures. Novel research imaging techniques, such as high-resolution peripheral quantitative computed tomography (HR-pQCT) provide non-invasive insights into bone microarchitecture of the peripheral skeleton. Using MR spectroscopy, bone marrow composition can be studied. Both methods have been shown to be capable of discriminating between type 2 diabetic patients with and without prevalent fragility fractures and thus bear the potential of improving the current standard of care. Currently both methods remain limited to clinical research applications. DXA and HR-pQCT are valid tools for the quantification of bone mineral density and assessment of fracture risk in patients with DM, especially if interpreted in the context of clinical risk factors. Radiography, CT and MRI are suitable for the detection of insufficiency fractures.
Sex estimation from sternal measurements using multidetector computed tomography.
Ekizoglu, Oguzhan; Hocaoglu, Elif; Inci, Ercan; Bilgili, Mustafa Gokhan; Solmaz, Dilek; Erdil, Irem; Can, Ismail Ozgur
2014-12-01
We aimed to show the utility and reliability of sternal morphometric analysis for sex estimation.Sex estimation is a very important step in forensic identification. Skeletal surveys are main methods for sex estimation studies. Morphometric analysis of sternum may provide high accuracy rated data in sex discrimination. In this study, morphometric analysis of sternum was evaluated in 1 mm chest computed tomography scans for sex estimation. Four hundred forty 3 subjects (202 female, 241 male, mean age: 44 ± 8.1 [distribution: 30-60 year old]) were included the study. Manubrium length (ML), mesosternum length (2L), Sternebra 1 (S1W), and Sternebra 3 (S3W) width were measured and also sternal index (SI) was calculated. Differences between genders were evaluated by student t-test. Predictive factors of sex were determined by discrimination analysis and receiver operating characteristic (ROC) analysis. Male sternal measurement values are significantly higher than females (P < 0.001) while SI is significantly low in males (P < 0.001). In discrimination analysis, MSL has high accuracy rate with 80.2% in females and 80.9% in males. MSL also has the best sensitivity (75.9%) and specificity (87.6%) values. Accuracy rates were above 80% in 3 stepwise discrimination analysis for both sexes. Stepwise 1 (ML, MSL, S1W, S3W) has the highest accuracy rate in stepwise discrimination analysis with 86.1% in females and 83.8% in males. Our study showed that morphometric computed tomography analysis of sternum might provide important information for sex estimation.
Assessing the Macro-Level Correlates of Malware Infections Using a Routine Activities Framework.
Holt, Thomas J; Burruss, George W; Bossler, Adam M
2018-05-01
The ability to gain unauthorized access to computer systems to engage in espionage and data theft poses a massive threat to individuals worldwide. There has been minimal focus, however, on the role of malicious software, or malware, which can automate this process. This study examined the macro-correlates of malware infection at the national level by using an open repository of known malware infections and utilizing a routine activities framework. Negative inflated binomial models for counts indicated that nations with greater technological infrastructure, more political freedoms, and with less organized crime financial impact were more likely to report malware infections. The number of Computer Emergency Response Teams (CERTs) in a nation was not significantly related with reported malware infection. The implications of the study for the understanding of malware infection, routine activity theory, and target-hardening strategies are discussed.
Stochastic determination of matrix determinants
NASA Astrophysics Data System (ADS)
Dorn, Sebastian; Enßlin, Torsten A.
2015-07-01
Matrix determinants play an important role in data analysis, in particular when Gaussian processes are involved. Due to currently exploding data volumes, linear operations—matrices—acting on the data are often not accessible directly but are only represented indirectly in form of a computer routine. Such a routine implements the transformation a data vector undergoes under matrix multiplication. While efficient probing routines to estimate a matrix's diagonal or trace, based solely on such computationally affordable matrix-vector multiplications, are well known and frequently used in signal inference, there is no stochastic estimate for its determinant. We introduce a probing method for the logarithm of a determinant of a linear operator. Our method rests upon a reformulation of the log-determinant by an integral representation and the transformation of the involved terms into stochastic expressions. This stochastic determinant determination enables large-size applications in Bayesian inference, in particular evidence calculations, model comparison, and posterior determination.
GEMPAK: An arbitrary aircraft geometry generator
NASA Technical Reports Server (NTRS)
Stack, S. H.; Edwards, C. L. W.; Small, W. J.
1977-01-01
A computer program, GEMPAK, has been developed to aid in the generation of detailed configuration geometry. The program was written to allow the user as much flexibility as possible in his choices of configurations and the detail of description desired and at the same time keep input requirements and program turnaround and cost to a minimum. The program consists of routines that generate fuselage and planar-surface (winglike) geometry and a routine that will determine the true intersection of all components with the fuselage. This paper describes the methods by which the various geometries are generated and provides input description with sample input and output. Also included are descriptions of the primary program variables and functions performed by the various routines. The FORTRAN program GEMPAK has been used extensively in conjunction with interfaces to several aerodynamic and plotting computer programs and has proven to be an effective aid in the preliminary design phase of aircraft configurations.
Stochastic determination of matrix determinants.
Dorn, Sebastian; Ensslin, Torsten A
2015-07-01
Matrix determinants play an important role in data analysis, in particular when Gaussian processes are involved. Due to currently exploding data volumes, linear operations-matrices-acting on the data are often not accessible directly but are only represented indirectly in form of a computer routine. Such a routine implements the transformation a data vector undergoes under matrix multiplication. While efficient probing routines to estimate a matrix's diagonal or trace, based solely on such computationally affordable matrix-vector multiplications, are well known and frequently used in signal inference, there is no stochastic estimate for its determinant. We introduce a probing method for the logarithm of a determinant of a linear operator. Our method rests upon a reformulation of the log-determinant by an integral representation and the transformation of the involved terms into stochastic expressions. This stochastic determinant determination enables large-size applications in Bayesian inference, in particular evidence calculations, model comparison, and posterior determination.
NASA Astrophysics Data System (ADS)
Li, Yutong; Wang, Yuxin; Duffy, Alex H. B.
2014-11-01
Computer-based conceptual design for routine design has made great strides, yet non-routine design has not been given due attention, and it is still poorly automated. Considering that the function-behavior-structure(FBS) model is widely used for modeling the conceptual design process, a computer-based creativity enhanced conceptual design model(CECD) for non-routine design of mechanical systems is presented. In the model, the leaf functions in the FBS model are decomposed into and represented with fine-grain basic operation actions(BOA), and the corresponding BOA set in the function domain is then constructed. Choosing building blocks from the database, and expressing their multiple functions with BOAs, the BOA set in the structure domain is formed. Through rule-based dynamic partition of the BOA set in the function domain, many variants of regenerated functional schemes are generated. For enhancing the capability to introduce new design variables into the conceptual design process, and dig out more innovative physical structure schemes, the indirect function-structure matching strategy based on reconstructing the combined structure schemes is adopted. By adjusting the tightness of the partition rules and the granularity of the divided BOA subsets, and making full use of the main function and secondary functions of each basic structure in the process of reconstructing of the physical structures, new design variables and variants are introduced into the physical structure scheme reconstructing process, and a great number of simpler physical structure schemes to accomplish the overall function organically are figured out. The creativity enhanced conceptual design model presented has a dominant capability in introducing new deign variables in function domain and digging out simpler physical structures to accomplish the overall function, therefore it can be utilized to solve non-routine conceptual design problem.
FFTs in external or hierarchical memory
NASA Technical Reports Server (NTRS)
Bailey, David H.
1989-01-01
A description is given of advanced techniques for computing an ordered FFT on a computer with external or hierarchical memory. These algorithms (1) require as few as two passes through the external data set, (2) use strictly unit stride, long vector transfers between main memory and external storage, (3) require only a modest amount of scratch space in main memory, and (4) are well suited for vector and parallel computation. Performance figures are included for implementations of some of these algorithms on Cray supercomputers. Of interest is the fact that a main memory version outperforms the current Cray library FFT routines on the Cray-2, the Cray X-MP, and the Cray Y-MP systems. Using all eight processors on the Cray Y-MP, this main memory routine runs at nearly 2 Gflops.
Orbiter/payload contamination control assessment support
NASA Technical Reports Server (NTRS)
Rantanen, R. O.; Strange, D. A.; Hetrick, M. A.
1978-01-01
The development and integration of 16 payload bay liner filters into the existing shuttle/payload contamination evaluation (SPACE) computer program is discussed as well as an initial mission profile model. As part of the mission profile model, a thermal conversion program, a temperature cycling routine, a flexible plot routine and a mission simulation of orbital flight test 3 are presented.
Such Stuff as Habits Are Made on: A Reply to Cooper and Shallice (2006)
ERIC Educational Resources Information Center
Botvinick, Matthew M.; Plaut, David C.
2006-01-01
The representations and mechanisms guiding everyday routine sequential action remain incompletely understood. In recent work, the authors proposed a computational model of routine sequential behavior that took the form of a recurrent neural network (M. Botvinick & D. C. Plaut, 2004). Subsequently, R. P. Cooper and T. Shallice (2006) put forth a…
Analyzing Pulse-Code Modulation On A Small Computer
NASA Technical Reports Server (NTRS)
Massey, David E.
1988-01-01
System for analysis pulse-code modulation (PCM) comprises personal computer, computer program, and peripheral interface adapter on circuit board that plugs into expansion bus of computer. Functions essentially as "snapshot" PCM decommutator, which accepts and stores thousands of frames of PCM data, sifts through them repeatedly to process according to routines specified by operator. Enables faster testing and involves less equipment than older testing systems.
Kakimoto, Naoya; Chindasombatjaroen, Jira; Tomita, Seiki; Shimamoto, Hiroaki; Uchiyama, Yuka; Hasegawa, Yoko; Kishino, Mitsunobu; Murakami, Shumei; Furukawa, Souhei
2013-01-01
The purpose of this study was to investigate the usefulness of computerized tomography (CT), particularly contrast-enhanced CT, in differentiation of jaw cysts and cystic-appearing tumors. We retrospectively analyzed contrast-enhanced CT images of 90 patients with odontogenic jaw cysts or cystic-appearing tumors. The lesion size and CT values were measured and the short axis to long axis (S/L) ratio, contrast enhancement (CE) ratio, and standard deviation ratio were calculated. The lesion size and the S/L ratio of keratocystic odontogenic tumors were significantly different from those of radicular cysts and follicular cysts. There were no significant differences in the CE ratio among the lesions. Multidetector CT provided diagnostic information about the size of odontogenic cysts and cystic-appearing tumors of the jaws that was related to the lesion type, but showed no relation between CE ratio and the type of these lesions. Copyright © 2013 Elsevier Inc. All rights reserved.
Latest results and perspectives of the KASCADE-Grande EAS Facility
NASA Astrophysics Data System (ADS)
Haungs, A.; Apel, W. D.; Arteaga-Velázquez, J. C.; Bekk, K.; Bertaina, M.; Blümer, J.; Bozdog, H.; Brancus, I. M.; Buchholz, P.; Cantoni, E.; Chiavassa, A.; Cossavella, F.; Daumiller, K.; de Souza, V.; di Pierro, F.; Doll, P.; Engel, R.; Engler, J.; Finger, M.; Fuhrmann, D.; Ghia, P. L.; Gils, H. J.; Glasstetter, R.; Grupen, C.; Heck, D.; Hörandel, J. R.; Huege, T.; Isar, P. G.; Kampert, K.-H.; Kang, D.; Kickelbick, D.; Klages, H. O.; Link, K.; Łuczak, P.; Ludwig, M.; Mathes, H. J.; Mayer, H. J.; Melissas, M.; Milke, J.; Mitrica, B.; Morello, C.; Navarra, G.; Nehls, S.; Oehlschläger, J.; Ostapchenko, S.; Over, S.; Palmieri, N.; Petcu, M.; Pierog, T.; Rebel, H.; Roth, M.; Schieler, H.; Schröder, F. G.; Sima, O.; Toma, G.; Trinchero, G. C.; Ulrich, H.; Weindl, A.; Wochele, J.; Wommer, M.; Zabierowski, J.
2012-01-01
KASCADE-Grande is a multi-detector experiment at KIT (Karlsruhe Institute of Technology) in Germany for measuring extensive air showers in the primary energy range of 100 TeV to 1 EeV. This paper does not provide a synopsis of all results of the KASCADE-Grande experiment. Rather it is focused on three aspects of current interests illustrating the advantages of a multi-detector facility. Results on the analysis of individual energy spectra of primary mass groups around the knee obtained by unfolding the shower size measurements of KASCADE with the help of the new hadronic interaction model EPOS and the all-particle energy spectrum at higher energies obtained by Grande measurements will be discussed. As KASCADE-Grande serves also as host of the LOPES radio detection experiment where both experiments measure the same showers, special emphasis will be given in comparing the characteristics and feasibility of both techniques in estimating the main parameters of high-energy primary cosmic rays: energy, composition, and arrival direction.
Zhu, Chengcheng; Patterson, Andrew J; Thomas, Owen M; Sadat, Umar; Graves, Martin J; Gillard, Jonathan H
2013-04-01
Luminal stenosis is used for selecting the optimal management strategy for patients with carotid artery disease. The aim of this study is to evaluate the reproducibility of carotid stenosis quantification using manual and automated segmentation methods using submillimeter through-plane resolution Multi-Detector CT angiography (MDCTA). 35 patients having carotid artery disease with >30 % luminal stenosis as identified by carotid duplex imaging underwent contrast enhanced MDCTA. Two experienced CT readers quantified carotid stenosis from axial source images, reconstructed maximum intensity projection (MIP) and 3D-carotid geometry which was automatically segmented by an open-source toolkit (Vascular Modelling Toolkit, VMTK) using NASCET criteria. Good agreement among the measurement using axial images, MIP and automatic segmentation was observed. Automatic segmentation methods show better inter-observer agreement between the readers (intra-class correlation coefficient (ICC): 0.99 for diameter stenosis measurement) than manual measurement of axial (ICC = 0.82) and MIP (ICC = 0.86) images. Carotid stenosis quantification using an automatic segmentation method has higher reproducibility compared with manual methods.
Controversies in imaging of hepatocellular carcinoma: multidetector CT (MDCT)
Silverman, Paul M; Szklaruk, Janio
2005-01-01
Primary hepatocellular carcinoma (HCC) is a significant tumor worldwide and represents the most common primary hepatic neoplasm. Staging criteria are important for appreciation of timely work up of these neoplasms in contradiction with surgical colleagues. This article demonstrates the appearance of HCC on multiphasic, multidetector CT (MDCT) and relates these findings to current staging criteria. The variable appearance on different planes of contrast is critical to appreciate in staging this neoplasm. The hypervascular nature of the primary tumor makes MDCT and three-phase imaging a critical feature in the detection and characterization of this tumor. This is especially critical in the patients who are candidates for surgical resection. Additionally, MDCT has allowed arterial phase imaging to define the vascular supply of the tumor. An accurate representation of the size and number of lesions is critical in not only the initial staging but also the follow-up of hepatocellular carcinoma. The post-treatment features including the appearance post-surgically and after radiofrequency ablation can be well appreciated on MDCT. PMID:16361147
Hanford meteorological station computer codes: Volume 9, The quality assurance computer codes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burk, K.W.; Andrews, G.L.
1989-02-01
The Hanford Meteorological Station (HMS) was established in 1944 on the Hanford Site to collect and archive meteorological data and provide weather forecasts and related services for Hanford Site approximately 1/2 mile east of the 200 West Area and is operated by PNL for the US Department of Energy. Meteorological data are collected from various sensors and equipment located on and off the Hanford Site. These data are stored in data bases on the Digital Equipment Corporation (DEC) VAX 11/750 at the HMS (hereafter referred to as the HMS computer). Files from those data bases are routinely transferred to themore » Emergency Management System (EMS) computer at the Unified Dose Assessment Center (UDAC). To ensure the quality and integrity of the HMS data, a set of Quality Assurance (QA) computer codes has been written. The codes will be routinely used by the HMS system manager or the data base custodian. The QA codes provide detailed output files that will be used in correcting erroneous data. The following sections in this volume describe the implementation and operation of QA computer codes. The appendices contain detailed descriptions, flow charts, and source code listings of each computer code. 2 refs.« less
NASA Astrophysics Data System (ADS)
Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae
2012-12-01
The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p < 0.05). The enhancement was evaluated based on a consensus of four observers. The enhancement pattern and the morphological features during the arterial and the delayed phases were correlated between the Gd-EOB-DTPA-enhanced MRI findings and the iodine-enhanced MDCT by using an adjusted x2 test. The SNRs, CNRs, and PSIL all had a greater detection rate in Gd-EOB-DTPA enhanced MRI than in iodine-enhanced MDCT. Hepatocyte-selective uptake was observed 20 minutes after the injection in the focal nodular hyperplasia (FNH, 9/9), adenoma (9/10), and highly-differentiated HCC (grade G1, 27/30). Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p < 0.05). For the preoperative detection of focal liver lesions, Gd-EOB-DTPA-enhanced MRI had a higher diagnostic value and higher detection rate than iodine-enhanced MDCT. The arterial and the delayed dynamic enhancement patterns, and the gadoxetic-acid-enhanced MR imaging can provide information on the possible degree of cellular differentiation of a HCC, adenoma or metastatic tumor.
Dynamic Edematous Response of the Human Heart to Myocardial Infarction
Fernández-Jiménez, Rodrigo; Barreiro-Pérez, Manuel; Martin-García, Ana; Sánchez-González, Javier; Agüero, Jaume; Galán-Arriola, Carlos; García-Prieto, Jaime; Díaz-Pelaez, Elena; Vara, Pedro; Martinez, Irene; Zamarro, Ivan; Garde, Beatriz; Sanz, Javier; Fuster, Valentin
2017-01-01
Background: Clinical protocols aimed to characterize the post–myocardial infarction (MI) heart by cardiac magnetic resonance (CMR) need to be standardized to take account of dynamic biological phenomena evolving early after the index ischemic event. Here, we evaluated the time course of edema reaction in patients with ST-segment–elevation MI by CMR and assessed its implications for myocardium-at-risk (MaR) quantification both in patients and in a large-animal model. Methods: A total of 16 patients with anterior ST-segment–elevation MI successfully treated by primary angioplasty and 16 matched controls were prospectively recruited. In total, 94 clinical CMR examinations were performed: patients with ST-segment–elevation MI were serially scanned (within the first 3 hours after reperfusion and at 1, 4, 7, and 40 days), and controls were scanned only once. T2 relaxation time in the myocardium (T2 mapping) and the extent of edema on T2-weighted short-tau triple inversion-recovery (ie, CMR-MaR) were evaluated at all time points. In the experimental study, 20 pigs underwent 40-minute ischemia/reperfusion followed by serial CMR examinations at 120 minutes and 1, 4, and 7 days after reperfusion. Reference MaR was assessed by contrast-multidetector computed tomography during the index coronary occlusion. Generalized linear mixed models were used to take account of repeated measurements. Results: In humans, T2 relaxation time in the ischemic myocardium declines significantly from early after reperfusion to 24 hours, and then increases up to day 4, reaching a plateau from which it decreases from day 7. Consequently, edema extent measured by T2-weighted short-tau triple inversion-recovery (CMR-MaR) varied with the timing of the CMR examination. These findings were confirmed in the experimental model by showing that only CMR-MaR values for day 4 and day 7 postreperfusion, coinciding with the deferred edema wave, were similar to values measured by reference contrast-multidetector computed tomography. Conclusions: Post-MI edema in patients follows a bimodal pattern that affects CMR estimates of MaR. Dynamic changes in post–ST-segment–elevation MI edema highlight the need for standardization of CMR timing to retrospectively delineate MaR and quantify myocardial salvage. According to the present clinical and experimental data, a time window between days 4 and 7 post-MI seems a good compromise solution for standardization. Further studies are needed to study the effect of other factors on these variables. PMID:28687712
Luo, Mingxu; Lv, You; Guo, Xiuyu; Song, Hongmei; Su, Guoqiang; Chen, Bo
2017-08-01
Multidetector computed tomography (MDCT) exhibited wide ranges of sensitivities and specificities for lymph node assessment of gastric cancer (GC) in several individual studies. This present meta-analysis was carried out to evaluate the value of MDCT in diagnosis of preoperative lymph node metastasis (LNM) and to explore the impact factors that might explain the heterogeneity of its diagnostic accuracy in GC. A comprehensive search was conducted to collect all the relevant studies about the value of MDCT in assessing LNM of GC within the PubMed, Cochrane library and Embase databases up to Feb 2, 2016. Two investigators independently screened the studies, extracted data, and evaluated the quality of included studies. The sensitivity, specificity, and area under ROC curve (AUC) were pooled to estimate the overall accuracy of MDCT. Meta-regression and subgroup analysis were carried out to identify the possible factors influencing the heterogeneity of the accuracy. A total of 27 studies with 6519 subjects were finally included. Overall, the pooled sensitivity, specificity, and AUC were 0.67 (95% CI: 0.56-0.77), 0.86 (95% CI: 0.81-0.90), and 0.86 (95% CI: 0.83-0.89), respectively. Meta-regression revealed that MDCT section thickness, proportion of serosal invasion, and publication year were the main significant impact factors in sensitivity, and MDCT section thickness, multiplanar reformation (MPR), and reference standard were the main significant impact factors in specificity. After the included studies were divided into 2 groups (Group A: studies with proportion of serosa-invasive GC subjects ≥50%; Group B: studies with proportion of serosa-invasive GC subjects <50%), the pooled sensitivity in Group A was significantly higher than in Group B (0.84 [95% CI: 0.75-0.90] vs 0.55 [95% CI: 0.41-0.68], P < .01). For early gastric cancer (EGC), the pooled sensitivity, specificity, and AUC were 0.34 (95% CI: 0.15-0.61), 0.91 (95% CI: 0.84-0.95), and 0.83 (95% CI: 0.80-0.86), respectively. To summarize, MDCT tends to be adequate to assess preoperative LNM in serosa-invasive GC, but insufficient for non-serosa-invasive GC (particularly for EGC) owing to its low sensitivity. Proportion of serosa-invasive GC subjects, MDCT section thickness, MPR, and reference standard are the main factors influencing its diagnostic accuracy.
Lebl, Darren R; Bono, Christopher M; Velmahos, George; Metkar, Umesh; Nguyen, Joseph; Harris, Mitchel B
2013-07-15
Retrospective analysis of prospective registry data. To determine the patient characteristics, risk factors, and fracture patterns associated with vertebral artery injury (VAI) in patients with blunt cervical spine injury. VAI associated with cervical spine trauma has the potential for catastrophical clinical sequelae. The patterns of cervical spine injury and patient characteristics associated with VAI remain to be determined. A retrospective review of prospectively collected data from the American College of Surgeons trauma registries at 3 level-1 trauma centers identified all patients with a cervical spine injury on multidetector computed tomographic scan during a 3-year period (January 1, 2007, to January 1, 2010). Fracture pattern and patient characteristics were recorded. Logistic multivariate regression analysis of independent predictors for VAI and subgroup analysis of neurological events related to VAI was performed. Twenty-one percent of 1204 patients with cervical injuries (n = 253) underwent screening for VAI by multidetector computed tomography angiogram. VAI was diagnosed in 17% (42 of 253), unilateral in 15% (38 of 253), and bilateral in 1.6% (4 of 253) and was associated with a lower Glasgow coma scale (P < 0.001), a higher injury severity score (P < 0.01), and a higher mortality (P < 0.001). VAI was associated with ankylosing spondylitis/diffuse idiopathic skeletal hyperosteosis (crude odds ratio [OR] = 8.04; 95% confidence interval [CI], 1.30-49.68; P = 0.034), and occipitocervical dissociation (P < 0.001) by univariate analysis and fracture displacement into the transverse foramen 1 mm or more (adjusted OR = 3.29; 95% CI, 1.15-9.41; P = 0.026), and basilar skull fracture (adjusted OR = 4.25; 95% CI, 1.25-14.47; P= 0.021), by multivariate regression model. Subgroup analyses of neurological events secondary to VAI occurred in 14% (6 of 42) and the stroke-related mortality rate was 4.8% (2 of 42). Neurological events were associated with male sex (P = 0.024), facet subluxation/dislocation (crude OR = 9.00; 95% CI, 1.51-53.74; P = 0.004) and the diagnosis of ankylosing spondylitis/diffuse idiopathic skeletal hyperosteosis (OR = 40.67; 95% CI, 5.27-313.96; P < 0.001). VAI associated with blunt cervical spine injury is a marker for more severely injured patients. High-risk patients with basilar skull fractures, occipitocervical dissociation, fracture displacement into the transverse foramen more than 1 mm, ankylosing spondylitis/diffuse idiopathic skeletal hyperosteosis, and facet subluxation/dislocation deserve focused consideration for VAI screening.
Computer Databases as an Educational Tool in the Basic Sciences.
ERIC Educational Resources Information Center
Friedman, Charles P.; And Others
1990-01-01
The University of North Carolina School of Medicine developed a computer database, INQUIRER, containing scientific information in bacteriology, and then integrated the database into routine educational activities for first-year medical students in their microbiology course. (Author/MLW)
Kröner, Anke; Binnekade, Jan M; Graat, Marleen E; Vroom, Margreeth B; Stoker, Jaap; Spronk, Peter E; Schultz, Marcus J
2008-01-01
Elimination of daily-routine chest radiographs (CXRs) may influence chest computed tomography (CT) and ultrasound practice in critically ill patients. This was a retrospective cohort study including all patients admitted to a university-affiliated intensive care unit during two consecutive periods of 5 months, one before and one after elimination of daily-routine CXR. Chest CT and ultrasound studies were identified retrospectively by using the radiology department information system. Indications for and the diagnostic/therapeutic yield of chest CT and ultrasound studies were collected. Elimination of daily-routine CXR resulted in a decrease of CXRs per patient day from 1.1 +/- 0.3 to 0.6 +/- 0.4 (P < 0.05). Elimination did not affect duration of stay or mortality rates. Neither the number of chest CT studies nor the ratio of chest CT studies per patient day changed with the intervention: Before elimination of daily-routine CXR, 52 chest CT studies were obtained from 747 patients; after elimination, 54 CT studies were obtained from 743 patients. Similarly, chest ultrasound practice was not affected by the change of CXR strategy: Before and after elimination, 21 and 27 chest ultrasound studies were performed, respectively. Also, timing of chest CT and ultrasound studies was not different between the two study periods. During the two periods, 40 of 106 chest CT studies (38%) and 18 of 48 chest ultrasound studies (38%) resulted in a change in therapy. The combined therapeutic yield of chest CT and ultrasound studies did not change with elimination of daily-routine CXR. Elimination of daily-routine CXRs may not affect chest CT and ultrasound practice in a multidisciplinary intensive care unit.
ERIC Educational Resources Information Center
Grandey, Robert C.
The development of computer-assisted instructional lessons on the following three topics is discussed: 1) the mole concept and chemical formulas, 2) concentration of solutions and quantities from chemical equations, and 3) balancing equations for oxidation-reduction reactions. Emphasis was placed on developing computer routines which interpret…
ERIC Educational Resources Information Center
Onaral, Banu; And Others
This report describes the development of a Drexel University electrical and computer engineering course on digital filter design that used interactive computing and graphics, and was one of three courses in a senior-level sequence on digital signal processing (DSP). Interactive and digital analysis/design routines and the interconnection of these…
Software for computing plant biomassBIOPAK users guide.
Joseph E. Means; Heather A. Hansen; Greg J. Koerper; Paul B Alaback; Mark W. Klopsch
1994-01-01
BIOPAK is a menu-driven package of computer programs for IBM-compatible personal computers that calculates the biomass, area, height, length, or volume of plant components (leaves, branches, stem, crown, and roots). The routines were written in FoxPro, Fortran, and C.BIOPAK was created to facilitate linking of a diverse array of vegetation datasets with the...
van Vugt, Raoul; Kool, Digna R; Deunk, Jaap; Edwards, Michael J R
2012-03-01
Currently, total body computed tomography (TBCT) is rapidly implemented in the evaluation of trauma patients. With this review, we aim to evaluate the clinical implications-mortality, change in treatment, and time management-of the routine use of TBCT in adult blunt high-energy trauma patients compared with a conservative approach with the use of conventional radiography, ultrasound, and selective computed tomography. A literature search for original studies on TBCT in blunt high-energy trauma patients was performed. Two independent observers included studies concerning mortality, change of treatment, and/or time management as outcome measures. For each article, relevant data were extracted and analyzed. In addition, the quality according to the Oxford levels of evidence was assessed. From 183 articles initially identified, the observers included nine original studies in consensus. One of three studies described a significant difference in mortality; four described a change of treatment in 2% to 27% of patients because of the use of TBCT. Five studies found a gain in time with the use of immediate routine TBCT. Eight studies scored a level of evidence of 2b and one of 3b. Current literature has predominantly suboptimal design to prove terminally that the routine use of TBCT results in improved survival of blunt high-energy trauma patients. TBCT can give a change of treatment and improves time intervals in the emergency department as compared with its selective use.
pureS2HAT: S 2HAT-based Pure E/B Harmonic Transforms
NASA Astrophysics Data System (ADS)
Grain, J.; Stompor, R.; Tristram, M.
2011-10-01
The pS2HAT routines allow efficient, parallel calculation of the so-called 'pure' polarized multipoles. The computed multipole coefficients are equal to the standard pseudo-multipoles calculated for the apodized sky maps of the Stokes parameters Q and U subsequently corrected by so-called counterterms. If the applied apodizations fullfill certain boundary conditions, these multipoles correspond to the pure multipoles. Pure multipoles of one type, i.e., either E or B, are ensured not to contain contributions from the other one, at least to within numerical artifacts. They can be therefore further used in the estimation of the sky power spectra via the pseudo power spectrum technique, which has to however correctly account for the applied apodization on the one hand, and the presence of the counterterms, on the other. In addition, the package contains the routines permitting calculation of the spin-weighted apodizations, given an input scalar, i.e., spin-0 window. The former are needed to compute the counterterms. It also provides routines for maps and window manipulations. The routines are written in C and based on the S2HAT library, which is used to perform all required spherical harmonic transforms as well as all inter-processor communication. They are therefore parallelized using MPI and follow the distributed-memory computational model. The data distribution patterns, pixelization choices, conventions etc are all as those assumed/allowed by the S2HAT library.
Lystrom, David J.
1972-01-01
Various methods of verifying real-time streamflow data are outlined in part II. Relatively large errors (those greater than 20-30 percent) can be detected readily by use of well-designed verification programs for a digital computer, and smaller errors can be detected only by discharge measurements and field observations. The capability to substitute a simulated discharge value for missing or erroneous data is incorporated in some of the verification routines described. The routines represent concepts ranging from basic statistical comparisons to complex watershed modeling and provide a selection from which real-time data users can choose a suitable level of verification.
Advanced Computational Methods for Thermal Radiative Heat Transfer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tencer, John; Carlberg, Kevin Thomas; Larsen, Marvin E.
2016-10-01
Participating media radiation (PMR) in weapon safety calculations for abnormal thermal environments are too costly to do routinely. This cost may be s ubstantially reduced by applying reduced order modeling (ROM) techniques. The application of ROM to PMR is a new and unique approach for this class of problems. This approach was investigated by the authors and shown to provide significant reductions in the computational expense associated with typical PMR simulations. Once this technology is migrated into production heat transfer analysis codes this capability will enable the routine use of PMR heat transfer in higher - fidelity simulations of weaponmore » resp onse in fire environments.« less
Conic state extrapolation. [computer program for space shuttle navigation and guidance requirements
NASA Technical Reports Server (NTRS)
Shepperd, S. W.; Robertson, W. M.
1973-01-01
The Conic State Extrapolation Routine provides the capability to conically extrapolate any spacecraft inertial state vector either backwards or forwards as a function of time or as a function of transfer angle. It is merely the coded form of two versions of the solution of the two-body differential equations of motion of the spacecraft center of mass. Because of its relatively fast computation speed and moderate accuracy, it serves as a preliminary navigation tool and as a method of obtaining quick solutions for targeting and guidance functions. More accurate (but slower) results are provided by the Precision State Extrapolation Routine.
Computer-aided navigation in dental implantology: 7 years of clinical experience.
Ewers, Rolf; Schicho, Kurt; Truppe, Michael; Seemann, Rudolf; Reichwein, Astrid; Figl, Michael; Wagner, Arne
2004-03-01
This long-term study gives a review over 7 years of research, development, and routine clinical application of computer-aided navigation technology in dental implantology. Benefits and disadvantages of up-to-date technologies are discussed. In the course of the current advancement, various hardware and software configurations are used. In the initial phase, universally applicable navigation software is adapted for implantology. Since 2001, a special software module for dental implantology is available. Preoperative planning is performed on the basis of prosthetic aspects and requirements. In clinical routine use, patient and drill positions are intraoperatively registered by means of optoelectronic tracking systems; during preclinical tests, electromagnetic trackers are also used. In 7 years (1995 to 2002), 55 patients with 327 dental implants were successfully positioned with computer-aided navigation technology. The mean number of implants per patient was 6 (minimum, 1; maximum, 11). No complications were observed; the preoperative planning could be exactly realized. The average expenditure of time for the preparation of a surgical intervention with navigation decreased from 2 to 3 days in the initial phase to one-half day in clinical routine use with software that is optimized for dental implantology. The use of computer-aided navigation technology can contribute to considerable quality improvement. Preoperative planning is exactly realized and intraoperative safety is increased, because damage to nerves or neighboring teeth can be avoided.
IUE Data Analysis Software for Personal Computers
NASA Technical Reports Server (NTRS)
Thompson, R.; Caplinger, J.; Taylor, L.; Lawton , P.
1996-01-01
This report summarizes the work performed for the program titled, "IUE Data Analysis Software for Personal Computers" awarded under Astrophysics Data Program NRA 92-OSSA-15. The work performed was completed over a 2-year period starting in April 1994. As a result of the project, 450 IDL routines and eight database tables are now available for distribution for Power Macintosh computers and Personal Computers running Windows 3.1.
libvaxdata: VAX data format conversion routines
Baker, Lawrence M.
2005-01-01
libvaxdata provides a collection of routines for converting numeric data-integer and floating-point-to and from the formats used on a Digital Equipment Corporation1 (DEC) VAX 32-bit minicomputer (Brunner, 1991). Since the VAX numeric data formats are inherited from those used on a DEC PDP-11 16-bit minicomputer, these routines can be used to convert PDP-11 data as well. VAX numeric data formats are also the default data formats used on DEC Alpha 64-bit minicomputers running OpenVMS The libvaxdata routines are callable from Fortran or C. They require that the caller use two's-complement format for integer data and IEEE 754 format (ANSI/IEEE, 1985) for floating-point data. They also require that the 'natural' size of a C int type (integer) is 32 bits. That is the case for most modern 32-bit and 64-bit computer systems. Nevertheless, you may wish to consult the Fortran or C compiler documentation on your system to be sure. Some Fortran compilers support conversion of VAX numeric data on-the-fly when reading or writing unformatted files, either as a compiler option or a run-time I/O option. This feature may be easier to use than the libvaxdata routines. Consult the Fortran compiler documentation on your system to determine if this alternative is available to you. 1Later Compaq Computer Corporation, now Hewlett-Packard Company
NASA Astrophysics Data System (ADS)
Ceres, M.; Heselton, L. R., III
1981-11-01
This manual describes the computer programs for the FIREFINDER Digital Topographic Data Verification-Library-Dubbing System (FFDTDVLDS), and will assist in the maintenance of these programs. The manual contains detailed flow diagrams and associated descriptions for each computer program routine and subroutine. Complete computer program listings are also included. This information should be used when changes are made in the computer programs. The operating system has been designed to minimize operator intervention.
Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?
Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R
2014-01-01
Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951
Minami, Keisuke; Yoneyama, Kihei; Izumo, Masaki; Suzuki, Kengo; Ogawa, Yasuyoshi; Chikaraishi, Kousuke; Ogawa, Yukihisa; Kobayashi, Yasuyuki; Furukawa, Toshiyuki; Tanabe, Yasuhiro; Akashi, Yoshihiro J
Computed tomography is the best noninvasive imaging modality for evaluating valve leaflet calcification. To evaluate the association of aortic valve leaflet calcification with instantaneous valve opening and closing using dynamic multidetector computed tomography (MDCT). We retrospectively evaluated 58 consecutive patients who underwent dynamic MDCT imaging. Aortic valve calcification (AVC) was quantified using the Agatston method. The aortic valve area (AVA) tracking curves were derived by planimetry during the cardiac cycle using all 20 phases (5% reconstruction). da/dt in cm 2 /s was calculated as the rate of change of AVA during opening (positive) or closing (negative). Patients were divided into 3 three groups according to Agatston score quartile: no AVC (Q2, Score 0, n = 18), mild AVC (Q3, Score 1-2254, n = 24), and severe AVC (Q4 Score >2254, n = 14). In multivariable linear regression, compared to the non AVC group, the mild and severe AVC groups had lower maximum AVA (by -1.71 cm 2 and -2.25 cm 2 , respectively), lower peak positive da/dt (by -21.88 cm 2 /s and -26.65 cm 2 /s, respectively), and higher peak negative da/dt (by 13.78 cm 2 /s and 18.11 cm 2 /s, respectively) (p < 0.05 for all comparisons). AVA and its opening and closing were influenced by leaflet calcification. The present study demonstrates the ability of dynamic MDCT imaging to assess quantitative aortic valve motion in a clinical setting. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, H; Wang, Y; Weng, H
Purpose: The national diagnostic reference levels (NDRLs) is an efficient, concise and powerful standard for optimizing radiation protection of a patient. However, for each hospital the dose-reducing potential of focusing on establishment of local DRLs (LDRLs). A lot of study reported that Computed tomography exam contributed majority radiation dose in different medical modalities, therefore, routine abdomen CT exam was choose in initial pilot study in our study. Besides the mAs of routine abdomen CT exam was decided automatic exposure control by linear attenuation is relate to body shape of patient. In this study we would like to establish the localmore » diagnostic reference levels of routine abdomen exam in computed tomography according to body weight of patient. Methods and Materials: There are two clinical CT scanners (a Toshiba Aquilion and a Siemens Sensation) were performed in this study. For CT examinations the basic recommended dosimetric quantity is the Computed Tomography Dose Index (CTDI). The patient sample involved 82 adult patients of both sexes and divided into three groups by their body weight (50–60 kg, 60–70 kg, 70–80 kg).Carried out the routine abdomen examinations, and all exposure parameters have been collected and the corresponding CTDIv and DLP values have been determined. The average values were compared with the European DRLs. Results: The majority of patients (75%) were between 50–70 Kg of body weight, the numbers of patient in each group of weight were 40–50:7; 50–60:29; 60–70:33; 70–80:13. The LDRLs in each group were 10.81mGy, 14.46mGy, 20.27mGy and 21.04mGy, respectively. The DLP were 477mGy, 630mGy, 887mGy and 959mGy, respectively. No matter which group the LDRLs were lower than European DRLs. Conclusions: We would like to state that this was a pioneer work in local hospital in Chiayi. We hope that this may lead the way to further developments in Taiwan.« less
Investigating Architectural Issues in Neuromorphic Computing
2009-06-01
An example of this is Diffusion Tensor Imaging ( DTI ), a variant of fMRI, which detects water diffusion. DTI is routinely applied at medical...model computed for a subfield positioned over a section of the silhouette dog’s hind leg . The illustrated angles roughly correspond to orientation
Refining Pragmatically-Appropriate Oral Communication via Computer-Simulated Conversations
ERIC Educational Resources Information Center
Sydorenko, Tetyana; Daurio, Phoebe; Thorne, Steven L.
2018-01-01
To address the problem of limited opportunities for practicing second language speaking in interaction, especially delicate interactions requiring pragmatic competence, we describe computer simulations designed for the oral practice of extended pragmatic routines and report on the affordances of such simulations for learning pragmatically…
NASA Astrophysics Data System (ADS)
López, J.; Hernández, J.; Gómez, P.; Faura, F.
2018-02-01
The VOFTools library includes efficient analytical and geometrical routines for (1) area/volume computation, (2) truncation operations that typically arise in VOF (volume of fluid) methods, (3) area/volume conservation enforcement (VCE) in PLIC (piecewise linear interface calculation) reconstruction and(4) computation of the distance from a given point to the reconstructed interface. The computation of a polyhedron volume uses an efficient formula based on a quadrilateral decomposition and a 2D projection of each polyhedron face. The analytical VCE method is based on coupling an interpolation procedure to bracket the solution with an improved final calculation step based on the above volume computation formula. Although the library was originally created to help develop highly accurate advection and reconstruction schemes in the context of VOF methods, it may have more general applications. To assess the performance of the supplied routines, different tests, which are provided in FORTRAN and C, were implemented for several 2D and 3D geometries.
Quantum supercharger library: hyper-parallelism of the Hartree-Fock method.
Fernandes, Kyle D; Renison, C Alicia; Naidoo, Kevin J
2015-07-05
We present here a set of algorithms that completely rewrites the Hartree-Fock (HF) computations common to many legacy electronic structure packages (such as GAMESS-US, GAMESS-UK, and NWChem) into a massively parallel compute scheme that takes advantage of hardware accelerators such as Graphical Processing Units (GPUs). The HF compute algorithm is core to a library of routines that we name the Quantum Supercharger Library (QSL). We briefly evaluate the QSL's performance and report that it accelerates a HF 6-31G Self-Consistent Field (SCF) computation by up to 20 times for medium sized molecules (such as a buckyball) when compared with mature Central Processing Unit algorithms available in the legacy codes in regular use by researchers. It achieves this acceleration by massive parallelization of the one- and two-electron integrals and optimization of the SCF and Direct Inversion in the Iterative Subspace routines through the use of GPU linear algebra libraries. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
1973-01-01
A shuttle (ARS) atmosphere revitalization subsystem active thermal control subsystem (ATCS) performance routine was developed. This computer program is adapted from the Shuttle EC/LSS Design Computer Program. The program was upgraded in three noteworthy areas: (1) The functional ARS/ATCS schematic has been revised to accurately synthesize the shuttle baseline system definition. (2) The program logic has been improved to provide a more accurate prediction of the integrated ARS/ATCS system performance. Additionally, the logic has been expanded to model all components and thermal loads in the ARS/ATCS system. (3) The program is designed to be used on the NASA JSC crew system division's programmable calculator system. As written the new computer routine has an average running time of five minutes. The use of desk top type calculation equipment, and the rapid response of the program provides the NASA with an analytical tool for trade studies to refine the system definition, and for test support of the RSECS or integrated Shuttle ARS/ATCS test programs.