Beno, Sarah M; Stasiewicz, Matthew J; Andrus, Alexis D; Ralyea, Robert D; Kent, David J; Martin, Nicole H; Wiedmann, Martin; Boor, Kathryn J
2016-12-01
Pathogen environmental monitoring programs (EMPs) are essential for food processing facilities of all sizes that produce ready-to-eat food products exposed to the processing environment. We developed, implemented, and evaluated EMPs targeting Listeria spp. and Salmonella in nine small cheese processing facilities, including seven farmstead facilities. Individual EMPs with monthly sample collection protocols were designed specifically for each facility. Salmonella was detected in only one facility, with likely introduction from the adjacent farm indicated by pulsed-field gel electrophoresis data. Listeria spp. were isolated from all nine facilities during routine sampling. The overall Listeria spp. (other than Listeria monocytogenes ) and L. monocytogenes prevalences in the 4,430 environmental samples collected were 6.03 and 1.35%, respectively. Molecular characterization and subtyping data suggested persistence of a given Listeria spp. strain in seven facilities and persistence of L. monocytogenes in four facilities. To assess routine sampling plans, validation sampling for Listeria spp. was performed in seven facilities after at least 6 months of routine sampling. This validation sampling was performed by independent individuals and included collection of 50 to 150 samples per facility, based on statistical sample size calculations. Two of the facilities had a significantly higher frequency of detection of Listeria spp. during the validation sampling than during routine sampling, whereas two other facilities had significantly lower frequencies of detection. This study provides a model for a science- and statistics-based approach to developing and validating pathogen EMPs.
Frégeau, Chantal J; Lett, C Marc; Elliott, Jim; Yensen, Craig; Fourney, Ron M
2008-05-01
An automated process has been developed for the analysis of forensic casework samples using TECAN Genesis RSP 150/8 or Freedom EVO liquid handling workstations equipped exclusively with nondisposable tips. Robot tip cleaning routines have been incorporated strategically within the DNA extraction process as well as at the end of each session. Alternative options were examined for cleaning the tips and different strategies were employed to verify cross-contamination. A 2% sodium hypochlorite wash (1/5th dilution of the 10.8% commercial bleach stock) proved to be the best overall approach for preventing cross-contamination of samples processed using our automated protocol. The bleach wash steps do not adversely impact the short tandem repeat (STR) profiles developed from DNA extracted robotically and allow for major cost savings through the implementation of fixed tips. We have demonstrated that robotic workstations equipped with fixed pipette tips can be used with confidence with properly designed tip washing routines to process casework samples using an adapted magnetic bead extraction protocol.
Mandal, Abhishek; Boatz, Jennifer C.; Wheeler, Travis; van der Wel, Patrick C. A.
2017-01-01
A number of recent advances in the field of magic-angle-spinning (MAS) solid-state NMR have enabled its application to a range of biological systems of ever increasing complexity. To retain biological relevance, these samples are increasingly studied in a hydrated state. At the same time, experimental feasibility requires the sample preparation process to attain a high sample concentration within the final MAS rotor. We discuss these considerations, and how they have led to a number of different approaches to MAS NMR sample preparation. We describe our experience of how custom-made (or commercially available) ultracentrifugal devices can facilitate a simple, fast and reliable sample preparation process. A number of groups have since adopted such tools, in some cases to prepare samples for sedimentation-style MAS NMR experiments. Here we argue for a more widespread adoption of their use for routine MAS NMR sample preparation. PMID:28229262
Birnie, Kate; Hay, Alastair D; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O'Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C; Sterne, Jonathan A C
2017-01-01
To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the "index test"), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service laboratories should consider adopting procedures used in the research laboratory for paediatric urine samples. Primary care clinicians should try to obtain clean catch samples, even in very young children.
Native microflora in fresh-cut processing plants and their potentials of biofilm formation
USDA-ARS?s Scientific Manuscript database
Representative food contact and non-food contact surfaces in two mid-sized fresh cut processing facilities were sampled for microbiological analyses post routine daily sanitization. Mesophilic and psychrotrophic bacteria on the sampled surfaces were isolated by plating on non-selective bacterial med...
Erramuzpe, Asier; Cortés, Jesús M; López, José I
2018-02-01
Intratumor heterogeneity (ITH) is an inherent process of tumor development that has received much attention in previous years, as it has become a major obstacle for the success of targeted therapies. ITH is also temporally unpredictable across tumor evolution, which makes its precise characterization even more problematic since detection success depends on the precise temporal snapshot at which ITH is analyzed. New and more efficient strategies for tumor sampling are needed to overcome these difficulties which currently rely entirely on the pathologist's interpretation. Recently, we showed that a new strategy, the multisite tumor sampling, works better than the routine sampling protocol for the ITH detection when the tumor time evolution was not taken into consideration. Here, we extend this work and compare the ITH detections of multisite tumor sampling and routine sampling protocols across tumor time evolution, and in particular, we provide in silico analyses of both strategies at early and late temporal stages for four different models of tumor evolution (linear, branched, neutral, and punctuated). Our results indicate that multisite tumor sampling outperforms routine protocols in detecting ITH at all different temporal stages of tumor evolution. We conclude that multisite tumor sampling is more advantageous than routine protocols in detecting intratumor heterogeneity.
Birnie, Kate; Hay, Alastair D.; Wootton, Mandy; Howe, Robin; MacGowan, Alasdair; Whiting, Penny; Lawton, Michael; Delaney, Brendan; Downing, Harriet; Dudley, Jan; Hollingworth, William; Lisles, Catherine; Little, Paul; O’Brien, Kathryn; Pickles, Timothy; Rumsby, Kate; Thomas-Jones, Emma; Van der Voort, Judith; Waldron, Cherry-Ann; Harman, Kim; Hood, Kerenza; Butler, Christopher C.; Sterne, Jonathan A. C.
2017-01-01
Objectives To compare the validity of diagnosis of urinary tract infection (UTI) through urine culture between samples processed in routine health service laboratories and those processed in a research laboratory. Population and methods We conducted a prospective diagnostic cohort study in 4808 acutely ill children aged <5 years attending UK primary health care. UTI, defined as pure/predominant growth ≥105 CFU/mL of a uropathogen (the reference standard), was diagnosed at routine health service laboratories and a central research laboratory by culture of urine samples. We calculated areas under the receiver-operator curve (AUC) for UTI predicted by pre-specified symptoms, signs and dipstick test results (the “index test”), separately according to whether samples were obtained by clean catch or nappy (diaper) pads. Results 251 (5.2%) and 88 (1.8%) children were classified as UTI positive by health service and research laboratories respectively. Agreement between laboratories was moderate (kappa = 0.36; 95% confidence interval [CI] 0.29, 0.43), and better for clean catch (0.54; 0.45, 0.63) than nappy pad samples (0.20; 0.12, 0.28). In clean catch samples, the AUC was lower for health service laboratories (AUC = 0.75; 95% CI 0.69, 0.80) than the research laboratory (0.86; 0.79, 0.92). Values of AUC were lower in nappy pad samples (0.65 [0.61, 0.70] and 0.79 [0.70, 0.88] for health service and research laboratory positivity, respectively) than clean catch samples. Conclusions The agreement of microbiological diagnosis of UTI comparing routine health service laboratories with a research laboratory was moderate for clean catch samples and poor for nappy pad samples and reliability is lower for nappy pad than for clean catch samples. Positive results from the research laboratory appear more likely to reflect real UTIs than those from routine health service laboratories, many of which (particularly from nappy pad samples) could be due to contamination. Health service laboratories should consider adopting procedures used in the research laboratory for paediatric urine samples. Primary care clinicians should try to obtain clean catch samples, even in very young children. PMID:28199403
A problem-solving routine for improving hospital operations.
Ghosh, Manimay; Sobek Ii, Durward K
2015-01-01
The purpose of this paper is to examine empirically why a systematic problem-solving routine can play an important role in the process improvement efforts of hospitals. Data on 18 process improvement cases were collected through semi-structured interviews, reports and other documents, and artifacts associated with the cases. The data were analyzed using a grounded theory approach. Adherence to all the steps of the problem-solving routine correlated to greater degrees of improvement across the sample. Analysis resulted in two models. The first partially explains why hospital workers tended to enact short-term solutions when faced with process-related problems; and tended not seek longer-term solutions that prevent problems from recurring. The second model highlights a set of self-reinforcing behaviors that are more likely to address problem recurrence and result in sustained process improvement. The study was conducted in one hospital setting. Hospital managers can improve patient care and increase operational efficiency by adopting and diffusing problem-solving routines that embody three key characteristics. This paper offers new insights on why caregivers adopt short-term approaches to problem solving. Three characteristics of an effective problem-solving routine in a healthcare setting are proposed.
Practical issues in implementing whole-genome-sequencing in routine diagnostic microbiology.
Rossen, J W A; Friedrich, A W; Moran-Gilad, J
2018-04-01
Next generation sequencing (NGS) is increasingly being used in clinical microbiology. Like every new technology adopted in microbiology, the integration of NGS into clinical and routine workflows must be carefully managed. To review the practical aspects of implementing bacterial whole genome sequencing (WGS) in routine diagnostic laboratories. Review of the literature and expert opinion. In this review, we discuss when and how to integrate whole genome sequencing (WGS) in the routine workflow of the clinical laboratory. In addition, as the microbiology laboratories have to adhere to various national and international regulations and criteria for their accreditation, we deliberate on quality control issues for using WGS in microbiology, including the importance of proficiency testing. Furthermore, the current and future place of this technology in the diagnostic hierarchy of microbiology is described as well as the necessity of maintaining backwards compatibility with already established methods. Finally, we speculate on the question of whether WGS can entirely replace routine microbiology in the future and the tension between the fact that most sequencers are designed to process multiple samples in parallel whereas for optimal diagnosis a one-by-one processing of the samples is preferred. Special reference is made to the cost and turnaround time of WGS in diagnostic laboratories. Further development is required to improve the workflow for WGS, in particular to shorten the turnaround time, reduce costs, and streamline downstream data analyses. Only when these processes reach maturity will reliance on WGS for routine patient management and infection control management become feasible, enabling the transformation of clinical microbiology into a genome-based and personalized diagnostic field. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Irregular analytical errors in diagnostic testing - a novel concept.
Vogeser, Michael; Seger, Christoph
2018-02-23
In laboratory medicine, routine periodic analyses for internal and external quality control measurements interpreted by statistical methods are mandatory for batch clearance. Data analysis of these process-oriented measurements allows for insight into random analytical variation and systematic calibration bias over time. However, in such a setting, any individual sample is not under individual quality control. The quality control measurements act only at the batch level. Quantitative or qualitative data derived for many effects and interferences associated with an individual diagnostic sample can compromise any analyte. It is obvious that a process for a quality-control-sample-based approach of quality assurance is not sensitive to such errors. To address the potential causes and nature of such analytical interference in individual samples more systematically, we suggest the introduction of a new term called the irregular (individual) analytical error. Practically, this term can be applied in any analytical assay that is traceable to a reference measurement system. For an individual sample an irregular analytical error is defined as an inaccuracy (which is the deviation from a reference measurement procedure result) of a test result that is so high it cannot be explained by measurement uncertainty of the utilized routine assay operating within the accepted limitations of the associated process quality control measurements. The deviation can be defined as the linear combination of the process measurement uncertainty and the method bias for the reference measurement system. Such errors should be coined irregular analytical errors of the individual sample. The measurement result is compromised either by an irregular effect associated with the individual composition (matrix) of the sample or an individual single sample associated processing error in the analytical process. Currently, the availability of reference measurement procedures is still highly limited, but LC-isotope-dilution mass spectrometry methods are increasingly used for pre-market validation of routine diagnostic assays (these tests also involve substantial sets of clinical validation samples). Based on this definition/terminology, we list recognized causes of irregular analytical error as a risk catalog for clinical chemistry in this article. These issues include reproducible individual analytical errors (e.g. caused by anti-reagent antibodies) and non-reproducible, sporadic errors (e.g. errors due to incorrect pipetting volume due to air bubbles in a sample), which can both lead to inaccurate results and risks for patients.
The LabTube - a novel microfluidic platform for assay automation in laboratory centrifuges.
Kloke, A; Fiebach, A R; Zhang, S; Drechsel, L; Niekrawietz, S; Hoehl, M M; Kneusel, R; Panthel, K; Steigert, J; von Stetten, F; Zengerle, R; Paust, N
2014-05-07
Assay automation is the key for successful transformation of modern biotechnology into routine workflows. Yet, it requires considerable investment in processing devices and auxiliary infrastructure, which is not cost-efficient for laboratories with low or medium sample throughput or point-of-care testing. To close this gap, we present the LabTube platform, which is based on assay specific disposable cartridges for processing in laboratory centrifuges. LabTube cartridges comprise interfaces for sample loading and downstream applications and fluidic unit operations for release of prestored reagents, mixing, and solid phase extraction. Process control is achieved by a centrifugally-actuated ballpen mechanism. To demonstrate the workflow and functionality of the LabTube platform, we show two LabTube automated sample preparation assays from laboratory routines: DNA extractions from whole blood and purification of His-tagged proteins. Equal DNA and protein yields were observed compared to manual reference runs, while LabTube automation could significantly reduce the hands-on-time to one minute per extraction.
Murigneux, Valentine; Dufour, Anne-Béatrice; Lobry, Jean R; Pène, Laurent
2014-07-01
About 120,000 reference samples are analyzed each year in the Forensic Laboratory of Lyon. A total of 1640 positive control experiments used to validate and optimize the analytical method in the routine process were submitted to a multivariate exploratory data analysis approach with the aim of better understanding the underlying sources of variability. The peak heights of the 16 genetic markers targeted by the AmpFℓSTR(®) Identifiler(®) STR kit were used as variables of interest. Six different 3130xl genetic analyzers located in the same controlled environment were involved. Two major sources of variability were found: (i) the DNA load of the sample modulates all peak heights in a similar way so that the 16 markers are highly correlated, (ii) the genetic analyzer used with a locus-specific response for peak height and a better sensitivity for the most recently acquired. Three markers (FGA, D3S1358, and D13S317) were found to be of special interest to predict the success rate observed in the routine process. © 2014 American Academy of Forensic Sciences.
Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario
2013-11-01
Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.
Brooks, M.H.; Schroder, L.J.; Willoughby, T.C.
1988-01-01
External quality assurance monitoring of the National Atmospheric Deposition Program (NADP) and National Trends Network (NTN) was performed by the U.S. Geological Survey during 1985. The monitoring consisted of three primary programs: (1) an intersite comparison program designed to assess the precision and accuracy of onsite pH and specific conductance measurements made by NADP and NTN site operators; (2) a blind audit sample program designed to assess the effect of routine field handling on the precision and bias of NADP and NTN wet deposition data; and (3) an interlaboratory comparison program designed to compare analytical data from the laboratory processing NADP and NTN samples with data produced by other laboratories routinely analyzing wet deposition samples and to provide estimates of individual laboratory precision. An average of 94% of the site operators participated in the four voluntary intersite comparisons during 1985. A larger percentage of participating site operators met the accuracy goal for specific conductance measurements (average, 87%) than for pH measurements (average, 67%). Overall precision was dependent on the actual specific conductance of the test solution and independent of the pH of the test solution. Data for the blind audit sample program indicated slight positive biases resulting from routine field handling for all analytes except specific conductance. These biases were not large enough to be significant for most data users. Data for the blind audit sample program also indicated that decreases in hydrogen ion concentration were accompanied by decreases in specific conductance. Precision estimates derived from the blind audit sample program indicate that the major source of uncertainty in wet deposition data is the routine field handling that each wet deposition sample receives. Results of the interlaboratory comparison program were similar to results of previous years ' evaluations, indicating that the participating laboratories produced comparable data when they analyzed identical wet deposition samples, and that the laboratory processing NADP and NTN samples achieved the best analyte precision of the participating laboratories. (Author 's abstract)
Fission gas bubble identification using MATLAB's image processing toolbox
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collette, R.
Automated image processing routines have the potential to aid in the fuel performance evaluation process by eliminating bias in human judgment that may vary from person-to-person or sample-to-sample. This study presents several MATLAB based image analysis routines designed for fission gas void identification in post-irradiation examination of uranium molybdenum (U–Mo) monolithic-type plate fuels. Frequency domain filtration, enlisted as a pre-processing technique, can eliminate artifacts from the image without compromising the critical features of interest. This process is coupled with a bilateral filter, an edge-preserving noise removal technique aimed at preparing the image for optimal segmentation. Adaptive thresholding proved to bemore » the most consistent gray-level feature segmentation technique for U–Mo fuel microstructures. The Sauvola adaptive threshold technique segments the image based on histogram weighting factors in stable contrast regions and local statistics in variable contrast regions. Once all processing is complete, the algorithm outputs the total fission gas void count, the mean void size, and the average porosity. The final results demonstrate an ability to extract fission gas void morphological data faster, more consistently, and at least as accurately as manual segmentation methods. - Highlights: •Automated image processing can aid in the fuel qualification process. •Routines are developed to characterize fission gas bubbles in irradiated U–Mo fuel. •Frequency domain filtration effectively eliminates FIB curtaining artifacts. •Adaptive thresholding proved to be the most accurate segmentation method. •The techniques established are ready to be applied to large scale data extraction testing.« less
Soft Real-Time PID Control on a VME Computer
NASA Technical Reports Server (NTRS)
Karayan, Vahag; Sander, Stanley; Cageao, Richard
2007-01-01
microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.
Predictive control of hollow-fiber bioreactors for the production of monoclonal antibodies.
Dowd, J E; Weber, I; Rodriguez, B; Piret, J M; Kwok, K E
1999-05-20
The selection of medium feed rates for perfusion bioreactors represents a challenge for process optimization, particularly in bioreactors that are sampled infrequently. When the present and immediate future of a bioprocess can be adequately described, predictive control can minimize deviations from set points in a manner that can maximize process consistency. Predictive control of perfusion hollow-fiber bioreactors was investigated in a series of hybridoma cell cultures that compared operator control to computer estimation of feed rates. Adaptive software routines were developed to estimate the current and predict the future glucose uptake and lactate production of the bioprocess at each sampling interval. The current and future glucose uptake rates were used to select the perfusion feed rate in a designed response to deviations from the set point values. The routines presented a graphical user interface through which the operator was able to view the up-to-date culture performance and assess the model description of the immediate future culture performance. In addition, fewer samples were taken in the computer-estimated cultures, reducing labor and analytical expense. The use of these predictive controller routines and the graphical user interface decreased the glucose and lactate concentration variances up to sevenfold, and antibody yields increased by 10% to 43%. Copyright 1999 John Wiley & Sons, Inc.
The visual assessment of broth cultures for tissue bank samples.
Varettas, Kerry
2017-09-01
The bioburden screening process of allograft musculoskeletal tissue samples received at the South Eastern Area Laboratory Services includes the routine use of solid agar and cooked meat (CM) broth media. CM has been routinely sub-cultured onto solid agar plates after aerobic incubation at 35 °C. This study will evaluate whether a visual assessment of CM can replace sub-culture by an in vitro inoculation and a prospective study. Eight challenge organisms were serially diluted and inoculated into CM. The average inoculum of 0.5-5.5 CFU produced visible turbidity of CM after 24-h incubation for 7 of the challenge organisms with one organism producing turbidity after 48-h incubation. The prospective study evaluated 222 CM of which 213 were visually clear and no-growth on sub-culture and 9 turbid CM which were culture positive. Broth cultures are an integral part of the bioburden screening process of allograft musculoskeletal tissue and swab samples and visual assessment of CM can replace sub-culture.
The Society of Toxicologic Pathology charged a Nervous System Sampling Working Group with devising recommended practices to routinely screen the central and peripheral nervous systems in Good Laboratory Practice-type nonclinical general toxicity studies. Brains should be trimmed ...
Abras, Alba; Ballart, Cristina; Llovet, Teresa; Roig, Carme; Gutiérrez, Cristina; Tebar, Silvia; Berenguer, Pere; Pinazo, María-Jesús; Posada, Elizabeth; Gascón, Joaquim; Schijman, Alejandro G; Gállego, Montserrat; Muñoz, Carmen
2018-01-01
Polymerase chain reaction (PCR) has become a useful tool for the diagnosis of Trypanosoma cruzi infection. The development of automated DNA extraction methodologies and PCR systems is an important step toward the standardization of protocols in routine diagnosis. To date, there are only two commercially available Real-Time PCR assays for the routine laboratory detection of T. cruzi DNA in clinical samples: TCRUZIDNA.CE (Diagnostic Bioprobes Srl) and RealCycler CHAG (Progenie Molecular). Our aim was to evaluate the RealCycler CHAG assay taking into account the whole process. We assessed the usefulness of an automated DNA extraction system based on magnetic particles (EZ1 Virus Mini Kit v2.0, Qiagen) combined with a commercially available Real-Time PCR assay targeting satellite DNA (SatDNA) of T. cruzi (RealCycler CHAG), a methodology used for routine diagnosis in our hospital. It was compared with a well-known strategy combining a commercial DNA isolation kit based on silica columns (High Pure PCR Template Preparation Kit, Roche Diagnostics) with an in-house Real-Time PCR targeting SatDNA. The results of the two methodologies were in almost perfect agreement, indicating they can be used interchangeably. However, when variations in protocol factors were applied (sample treatment, extraction method and Real-Time PCR), the results were less convincing. A comprehensive fine-tuning of the whole procedure is the key to successful results. Guanidine EDTA-blood (GEB) samples are not suitable for DNA extraction based on magnetic particles due to inhibition, at least when samples are not processed immediately. This is the first study to evaluate the RealCycler CHAG assay taking into account the overall process, including three variables (sample treatment, extraction method and Real-Time PCR). Our findings may contribute to the harmonization of protocols between laboratories and to a wider application of Real-Time PCR in molecular diagnostic laboratories associated with health centers.
Fission gas bubble identification using MATLAB's image processing toolbox
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collette, R.; King, J.; Keiser, Jr., D.
Automated image processing routines have the potential to aid in the fuel performance evaluation process by eliminating bias in human judgment that may vary from person-to-person or sample-to-sample. In addition, this study presents several MATLAB based image analysis routines designed for fission gas void identification in post-irradiation examination of uranium molybdenum (U–Mo) monolithic-type plate fuels. Frequency domain filtration, enlisted as a pre-processing technique, can eliminate artifacts from the image without compromising the critical features of interest. This process is coupled with a bilateral filter, an edge-preserving noise removal technique aimed at preparing the image for optimal segmentation. Adaptive thresholding provedmore » to be the most consistent gray-level feature segmentation technique for U–Mo fuel microstructures. The Sauvola adaptive threshold technique segments the image based on histogram weighting factors in stable contrast regions and local statistics in variable contrast regions. Once all processing is complete, the algorithm outputs the total fission gas void count, the mean void size, and the average porosity. The final results demonstrate an ability to extract fission gas void morphological data faster, more consistently, and at least as accurately as manual segmentation methods.« less
Fission gas bubble identification using MATLAB's image processing toolbox
Collette, R.; King, J.; Keiser, Jr., D.; ...
2016-06-08
Automated image processing routines have the potential to aid in the fuel performance evaluation process by eliminating bias in human judgment that may vary from person-to-person or sample-to-sample. In addition, this study presents several MATLAB based image analysis routines designed for fission gas void identification in post-irradiation examination of uranium molybdenum (U–Mo) monolithic-type plate fuels. Frequency domain filtration, enlisted as a pre-processing technique, can eliminate artifacts from the image without compromising the critical features of interest. This process is coupled with a bilateral filter, an edge-preserving noise removal technique aimed at preparing the image for optimal segmentation. Adaptive thresholding provedmore » to be the most consistent gray-level feature segmentation technique for U–Mo fuel microstructures. The Sauvola adaptive threshold technique segments the image based on histogram weighting factors in stable contrast regions and local statistics in variable contrast regions. Once all processing is complete, the algorithm outputs the total fission gas void count, the mean void size, and the average porosity. The final results demonstrate an ability to extract fission gas void morphological data faster, more consistently, and at least as accurately as manual segmentation methods.« less
Wyllie, David H; Sanderson, Nicholas; Myers, Richard; Peto, Tim; Robinson, Esther; Crook, Derrick W; Smith, E Grace; Walker, A Sarah
2018-06-06
Contact tracing requires reliable identification of closely related bacterial isolates. When we noticed the reporting of artefactual variation between M. tuberculosis isolates during routine next generation sequencing of Mycobacterium spp, we investigated its basis in 2,018 consecutive M. tuberculosis isolates. In the routine process used, clinical samples were decontaminated and inoculated into broth cultures; from positive broth cultures DNA was extracted, sequenced, reads mapped, and consensus sequences determined. We investigated the process of consensus sequence determination, which selects the most common nucleotide at each position. Having determined the high-quality read depth and depth of minor variants across 8,006 M. tuberculosis genomic regions, we quantified the relationship between the minor variant depth and the amount of non-Mycobacterial bacterial DNA, which originates from commensal microbes killed during sample decontamination. In the presence of non-Mycobacterial bacterial DNA, we found significant increases in minor variant frequencies of more than 1.5 fold in 242 regions covering 5.1% of the M. tuberculosis genome. Included within these were four high variation regions strongly influenced by the amount of non-Mycobacterial bacterial DNA. Excluding these four regions from pairwise distance comparisons reduced biologically implausible variation from 5.2% to 0% in an independent validation set derived from 226 individuals. Thus, we have demonstrated an approach identifying critical genomic regions contributing to clinically relevant artefactual variation in bacterial similarity searches. The approach described monitors the outputs of the complex multi-step laboratory and bioinformatics process, allows periodic process adjustments, and will have application to quality control of routine bacterial genomics. Copyright © 2018 Wyllie et al.
Microfluidic Sample Preparation for Diagnostic Cytopathology
Mach, Albert J.; Adeyiga, Oladunni B.; Di Carlo, Dino
2014-01-01
The cellular components of body fluids are routinely analyzed to identify disease and treatment approaches. While significant focus has been placed on developing cell analysis technologies, tools to automate the preparation of cellular specimens have been more limited, especially for body fluids beyond blood. Preparation steps include separating, concentrating, and exposing cells to reagents. Sample preparation continues to be routinely performed off-chip by technicians, preventing cell-based point-of-care diagnostics, increasing the cost of tests, and reducing the consistency of the final analysis following multiple manually-performed steps. Here, we review the assortment of biofluids for which suspended cells are analyzed, along with their characteristics and diagnostic value. We present an overview of the conventional sample preparation processes for cytological diagnosis. We finally discuss the challenges and opportunities in developing microfluidic devices for the purpose of automating or miniaturizing these processes, with particular emphases on preparing large or small volume samples, working with samples of high cellularity, automating multi-step processes, and obtaining high purity subpopulations of cells. We hope to convey the importance of and help identify new research directions addressing the vast biological and clinical applications in preparing and analyzing the array of available biological fluids. Successfully addressing the challenges described in this review can lead to inexpensive systems to improve diagnostic accuracy while simultaneously reducing overall systemic healthcare costs. PMID:23380972
Mansell, Erin; Lunt, Helen; Docherty, Paul
2017-06-01
Delayed separation of red cells from plasma causes pre analytical glucose loss, which in turn results in an under-diagnosis of GDM (gestational diabetes) based on the OGTT (oral glucose tolerance test). In silico investigations may help laboratory decision making, when exploring pragmatic improvements to sample processing. Late pregnancy 0, 1 and 2h 75g OGTT values were obtained from two distinct populations of pregnant women: 1. Values derived from the HAPO (Hyperglycemia and Adverse Pregnancy Outcome) Study and 2. New Zealand women identified as at higher risk of GDM by their caregivers, undergoing OGTT during routine antenatal care. In both populations studied, in silico modelling focussed on the effects of pre-analytical delays in plasma separation, when using fluoride collection tubes. Using a model that 'batched' samples from the three OGTT collection times, diagnostic sensitivity was estimated as follows: 66.1% for HAPO research population and 48.4% for the 1305 women receiving routine antenatal care. If samples were not batched, but processed shortly after each blood sample was collected, then sensitivity increased to 81%. Exploration of a range of clinical and laboratory scenarios using in silico modelling, showed that delaying the processing of pregnancy OGTT samples, using batched sample collection into fluoride tubes, causes unacceptable loss of GDM diagnostic sensitivity across two distinct population groups. This modelling approach will hopefully provide information that helps with final decision making around improved laboratory processing techniques. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Van Nevel, S; Koetzsch, S; Proctor, C R; Besmer, M D; Prest, E I; Vrouwenvelder, J S; Knezev, A; Boon, N; Hammes, F
2017-04-15
Drinking water utilities and researchers continue to rely on the century-old heterotrophic plate counts (HPC) method for routine assessment of general microbiological water quality. Bacterial cell counting with flow cytometry (FCM) is one of a number of alternative methods that challenge this status quo and provide an opportunity for improved water quality monitoring. After more than a decade of application in drinking water research, FCM methodology is optimised and established for routine application, supported by a considerable amount of data from multiple full-scale studies. Bacterial cell concentrations obtained by FCM enable quantification of the entire bacterial community instead of the minute fraction of cultivable bacteria detected with HPC (typically < 1% of all bacteria). FCM measurements are reproducible with relative standard deviations below 3% and can be available within 15 min of samples arriving in the laboratory. High throughput sample processing and complete automation are feasible and FCM analysis is arguably less expensive than HPC when measuring more than 15 water samples per day, depending on the laboratory and selected staining procedure(s). Moreover, many studies have shown FCM total (TCC) and intact (ICC) cell concentrations to be reliable and robust process variables, responsive to changes in the bacterial abundance and relevant for characterising and monitoring drinking water treatment and distribution systems. The purpose of this critical review is to initiate a constructive discussion on whether FCM could replace HPC in routine water quality monitoring. We argue that FCM provides a faster, more descriptive and more representative quantification of bacterial abundance in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rapid Radiochemical Methods for Asphalt Paving Material ...
Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice
Wagner, Martin; Stessl, Beatrix
2014-01-01
The Listeria monitoring program for Austrian cheese factories was established in 1988. The basic idea is to control the introduction of L. monocytogenes into the food processing environment, preventing the pathogen from contaminating the food under processing. The Austrian Listeria monitoring program comprises four levels of investigation, dealing with routine monitoring of samples and consequences of finding a positive sample. Preventive quality control concepts attempt to detect a foodborne hazard along the food processing chain, prior to food delivery, retailing, and consumption. The implementation of a preventive food safety concept provokes a deepened insight by the manufacturers into problems concerning food safety. The development of preventive quality assurance strategies contributes to the national food safety status and protects public health.
Willems, Sander; Fraiture, Marie-Alice; Deforce, Dieter; De Keersmaecker, Sigrid C J; De Loose, Marc; Ruttink, Tom; Herman, Philippe; Van Nieuwerburgh, Filip; Roosens, Nancy
2016-02-01
Because the number and diversity of genetically modified (GM) crops has significantly increased, their analysis based on real-time PCR (qPCR) methods is becoming increasingly complex and laborious. While several pioneers already investigated Next Generation Sequencing (NGS) as an alternative to qPCR, its practical use has not been assessed for routine analysis. In this study a statistical framework was developed to predict the number of NGS reads needed to detect transgene sequences, to prove their integration into the host genome and to identify the specific transgene event in a sample with known composition. This framework was validated by applying it to experimental data from food matrices composed of pure GM rice, processed GM rice (noodles) or a 10% GM/non-GM rice mixture, revealing some influential factors. Finally, feasibility of NGS for routine analysis of GM crops was investigated by applying the framework to samples commonly encountered in routine analysis of GM crops. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
How to: identify non-tuberculous Mycobacterium species using MALDI-TOF mass spectrometry.
Alcaide, F; Amlerová, J; Bou, G; Ceyssens, P J; Coll, P; Corcoran, D; Fangous, M-S; González-Álvarez, I; Gorton, R; Greub, G; Hery-Arnaud, G; Hrábak, J; Ingebretsen, A; Lucey, B; Marekoviċ, I; Mediavilla-Gradolph, C; Monté, M R; O'Connor, J; O'Mahony, J; Opota, O; O'Reilly, B; Orth-Höller, D; Oviaño, M; Palacios, J J; Palop, B; Pranada, A B; Quiroga, L; Rodríguez-Temporal, D; Ruiz-Serrano, M J; Tudó, G; Van den Bossche, A; van Ingen, J; Rodriguez-Sanchez, B
2018-06-01
The implementation of MALDI-TOF MS for microorganism identification has changed the routine of the microbiology laboratories as we knew it. Most microorganisms can now be reliably identified within minutes using this inexpensive, user-friendly methodology. However, its application in the identification of mycobacteria isolates has been hampered by the structure of their cell wall. Improvements in the sample processing method and in the available database have proved key factors for the rapid and reliable identification of non-tuberculous mycobacteria isolates using MALDI-TOF MS. The main objective is to provide information about the proceedings for the identification of non-tuberculous isolates using MALDI-TOF MS and to review different sample processing methods, available databases, and the interpretation of the results. Results from relevant studies on the use of the available MALDI-TOF MS instruments, the implementation of innovative sample processing methods, or the implementation of improved databases are discussed. Insight about the methodology required for reliable identification of non-tuberculous mycobacteria and its implementation in the microbiology laboratory routine is provided. Microbiology laboratories where MALDI-TOF MS is available can benefit from its capacity to identify most clinically interesting non-tuberculous mycobacteria in a rapid, reliable, and inexpensive manner. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
An integrated strategy combining DNA walking and NGS to detect GMOs.
Fraiture, Marie-Alice; Herman, Philippe; Papazova, Nina; De Loose, Marc; Deforce, Dieter; Ruttink, Tom; Roosens, Nancy H
2017-10-01
Recently, we developed a DNA walking system for the detection and characterization of a broad spectrum of GMOs in routine analysis of food/feed matrices. Here, we present a new version with improved throughput and sensitivity by coupling the DNA walking system to Pacific Bioscience® Next-generation sequencing technology. The performance of the new strategy was thoroughly assessed through several assays. First, we tested its detection and identification capability on grains with high or low GMO content. Second, the potential impacts of food processing were investigated using rice noodle samples. Finally, GMO mixtures and a real-life sample were analyzed to illustrate the applicability of the proposed strategy in routine GMO analysis. In all tested samples, the presence of multiple GMOs was unambiguously proven by the characterization of transgene flanking regions and the combinations of elements that are typical for transgene constructs. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Ogata, Y; Nishizawa, K
1995-10-01
An automated smear counting and data processing system for a life science laboratory was developed to facilitate routine surveys and eliminate human errors by using a notebook computer. This system was composed of a personal computer, a liquid scintillation counter and a well-type NaI(Tl) scintillation counter. The radioactivity of smear samples was automatically measured by these counters. The personal computer received raw signals from the counters through an interface of RS-232C. The software for the computer evaluated the surface density of each radioisotope and printed out that value along with other items as a report. The software was programmed in Pascal language. This system was successfully applied to routine surveys for contamination in our facility.
Noble, H; Estcourt, C; Ison, C; Goold, P; Tite, L; Carter, Y H
2004-06-01
To describe the management of vaginal discharge in general practice, with particular regard to the use of the high vaginal swab (HVS), and to compare GPs' expectations of this test with the processing and reporting undertaken by different laboratories. A postal questionnaire survey of 2146 GPs in the North Thames area and postal questionnaire study of the 22 laboratories serving the same GPs were carried out. GPs were asked how they would manage a young woman with vaginal discharge and what information they would like on an HVS report. Laboratories were asked how they would process and report on the HVS sample from the same patient. Response rate was 26%. 72% of GPs would take an HVS and 62% would refer on to a genitourinary medicine (GUM) clinic. 45% would offer empirical therapy and 47% of these would treat for candida initially. 75% of GPs routinely request "M,C&S" on HVS samples but 55% only want to be informed about specific pathogens. Routine processing of HVS samples varies widely between laboratories and 86% only report specific pathogens. 78% of GPs would like to be offered a suggested diagnosis on HVS reports, and 74% would like a suggested treatment. 43% of laboratories ever provide a diagnosis, and 14% provide a suggested treatment. GPs frequently manage vaginal discharge and most of them utilise the HVS. GPs' expectations of the test are not well matched to laboratory processing or reporting of the samples.
Ansermot, Nicolas; Rudaz, Serge; Brawand-Amey, Marlyse; Fleury-Souverain, Sandrine; Veuthey, Jean-Luc; Eap, Chin B
2009-08-01
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Martins, Magda Targa; Melo, Jéssica; Barreto, Fabiano; Hoff, Rodrigo Barcellos; Jank, Louise; Bittencourt, Michele Soares; Arsand, Juliana Bazzan; Schapoval, Elfrides Eva Scherman
2014-11-01
In routine laboratory work, screening methods for multiclass analysis can process a large number of samples in a short time. The main challenge is to develop a methodology to detect as many different classes of residues as possible, combined with speed and low cost. An efficient technique for the analysis of multiclass antibacterial residues (fluoroquinolones, tetracyclines, sulfonamides and trimethoprim) was developed based on simple, environment-friendly extraction for bovine milk, cattle and poultry liver. Acidified ethanol was used as an extracting solvent for milk samples. Liver samples were treated using EDTA-washed sand for cell disruption, methanol:water and acidified acetonitrile as extracting solvent. A total of 24 antibacterial residues were detected and confirmed using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), at levels between 10, 25 and 50% of the maximum residue limit (MRL). For liver samples a metabolite (sulfaquinoxaline-OH) was also monitored. A validation procedure was conducted for screening purposes in accordance with European Union requirements (2002/657/EC). The detection capability (CCβ) false compliant rate was less than 5% at the lowest level for each residue. Specificity and ruggedness were also discussed. Incurred and routine samples were analyzed and the method was successfully applied. The results proved that this method can be an important tool in routine analysis, since it is very fast and reliable. Copyright © 2014. Published by Elsevier B.V.
A microcomputer-based whole-body counter for personnel routine monitoring.
Chou, H P; Tsai, T M; Lan, C Y
1993-05-01
The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.
Beussink, Amy M.; Burnich, Michael R.
2009-01-01
Lake Houston, a reservoir impounded in 1954 by the City of Houston, Texas, is a primary source of drinking water for Houston and surrounding areas. The U.S. Geological Survey, in cooperation with the City of Houston, developed a continuous water-quality monitoring network to track daily changes in water quality in the southwestern quadrant of Lake Houston beginning in 2006. Continuous water-quality data (the physiochemical properties water temperature, specific conductance, pH, dissolved oxygen concentration, and turbidity) were collected from Lake Houston to characterize the in-lake processes that affect water quality. Continuous data were collected hourly from mobile, multi-depth monitoring stations developed and constructed by the U.S. Geological Survey. Multi-depth monitoring stations were installed at five sites in three general locations in the southwestern quadrant of the lake. Discrete water-quality data (samples) were collected routinely (once or twice each month) at all sites to characterize the chemical and biological (phytoplankton and bacteria) response to changes in the continuous water-quality properties. Physiochemical properties (the five continuously monitored plus transparency) were measured in the field when samples were collected. In addition to the routine samples, discrete water-quality samples were collected synoptically (one or two times during the study period) at all sites to determine the presence and levels of selected constituents not analyzed in routine samples. Routine samples were measured or analyzed for acid neutralizing capacity; selected major ions and trace elements (calcium, silica, and manganese); nutrients (filtered and total ammonia nitrogen, filtered nitrate plus nitrite nitrogen, total nitrate nitrogen, filtered and total nitrite nitrogen, filtered and total orthophosphate phosphorus, total phosphorus, total nitrogen, total organic carbon); fecal indicator bacteria (total coliform and Escherichia coli); sediment (suspended-sediment concentration and loss-on-ignition); actinomycetes bacteria; taste-and-odor-causing compounds (2-methylisoborneol and geosmin); cyanobacterial toxins (total microcystins); and phytoplankton abundance, biovolume, and community composition (taxonomic identification to genus). Synoptic samples were analyzed for major ions, trace elements, wastewater indicators, pesticides, volatile organic compounds, and carbon. The analytical data are presented in tables by type (continuous, discrete routine, discrete synoptic) and listed by station number. Continuously monitored properties (except pH) also are displayed graphically.
La Scola, Bernard; Raoult, Didier
2009-11-25
With long delays observed between sampling and availability of results, the usefulness of blood cultures in the context of emergency infectious diseases has recently been questioned. Among methods that allow quicker bacterial identification from growing colonies, matrix-assisted laser desorption ionisation time-of-flight (MALDI-TOF) mass spectrometry was demonstrated to accurately identify bacteria routinely isolated in a clinical biology laboratory. In order to speed up the identification process, in the present work we attempted bacterial identification directly from blood culture bottles detected positive by the automate. We prospectively analysed routine MALDI-TOF identification of bacteria detected in blood culture by two different protocols involving successive centrifugations and then lysis by trifluoroacetic acid or formic acid. Of the 562 blood culture broths detected as positive by the automate and containing one bacterial species, 370 (66%) were correctly identified. Changing the protocol from trifluoroacetic acid to formic acid improved identification of Staphylococci, and overall correct identification increased from 59% to 76%. Lack of identification was observed mostly with viridans streptococci, and only one false positive was observed. In the 22 positive blood culture broths that contained two or more different species, only one of the species was identified in 18 samples, no species were identified in two samples and false species identifications were obtained in two cases. The positive predictive value of bacterial identification using this procedure was 99.2%. MALDI-TOF MS is an efficient method for direct routine identification of bacterial isolates in blood culture, with the exception of polymicrobial samples and viridans streptococci. It may replace routine identification performed on colonies, provided improvement for the specificity of blood culture broths growing viridans streptococci is obtained in the near future.
Korać, P; Jones, M; Dominis, M; Kušec, R; Mason, D Y; Banham, A H; Ventura, R A
2005-01-01
The use of interphase fluorescence in situ hybridisation (FISH) to study cytogenetic abnormalities in routinely fixed paraffin wax embedded tissue has become commonplace over the past decade. However, very few studies have applied FISH to routinely fixed bone marrow trephines (BMTs). This may be because of the acid based decalcification methods that are commonly used during the processing of BMTs, which may adversely affect the suitability of the sample for FISH analysis. For the first time, this report describes the simultaneous application of FISH and immunofluorescent staining (the FICTION technique) to formalin fixed, EDTA decalcified and paraffin wax embedded BMTs. This technique allows the direct correlation of genetic abnormalities to immunophenotype, and therefore will be particularly useful for the identification of genetic abnormalities in specific tumour cells present in BMTs. The application of this to routine clinical practice will assist diagnosis and the detection of minimal residual disease. PMID:16311361
Sandstrom, Mark W.; Kanagy, Leslie K.; Anderson, Cyrissa A.; Kanagy, Christopher J.
2016-01-11
Mean recoveries of most analytes (223 of 229) were within data-quality objectives of 100±30 percent at spike concentrations above method detection levels (MDLs) in all four matrices. The calculated MDLs ranged from 1 to 103 nanograms per liter (ng/L) for 182 analytes analyzed in the ESI positive mode, and from 2 to 106 ng/L for 42 analytes analyzed in the ESI negative mode. Five analytes had MDLs between 100 and 250 ng/L. The stability studies in reagent water demonstrated that the largest number of the pesticide compounds (227 of 229) were stable after 14 days of storage at 4 degrees Celsius, so these were selected as the practical holding time and storage temperature for routine sample processing. The use of antimicrobial reagent citric acid to adjust the sample pH to about 4 also resulted in lower recoveries of some analytes, so it should not be used as a routine sample preservative.
2007 Chicago Regional Household Travel Inventory | Transportation Secure
period. In addition to traditional survey-based data collection, this study featured a sub-sample of processing and filtering routines. Survey Records Survey records include 460 households. More Information For more information about the survey, see the CMAP Regional Travel Survey Final Report. Transportation
ERIC Educational Resources Information Center
Putwain, David W.; Daly, Anthony L.; Chamberlain, Suzanne; Sadreddini, Shireen
2016-01-01
This study explores the relationship between students' self-report levels of cognitive test anxiety (worry), academic buoyancy (withstanding and successfully responding to routine school challenges and setbacks), coping processes and their achieved grades in high-stakes national examinations at the end of compulsory schooling. The sample comprised…
Kieninger, M; Zech, N; Mulzer, Y; Bele, S; Seemann, M; Künzig, H; Schneiker, A; Gruber, M
2015-05-01
Point of care testing with blood gas analysis (BGA) is an important factor for intensive care medicine. Continuous efforts to optimize workflow, improve safety for the staff and avoid preanalytical mistakes are important and should reflect quality management standards. In a prospective observational study it was investigated whether the implementation of a new system for BGA using labeled syringes and automated processing of the specimens leads to improvements compared to the previously used procedure. In a 4-week test period the time until receiving the final results of the BGA with the standard method used in the clinical routine (control group) was compared to the results in a second 4-week test period using the new labeled syringes and automated processing of the specimens (intervention group). In addition, preanalytical mistakes with both systems were checked during routine daily use. Finally, it was investigated whether a delay of 10 min between taking and analyzing the blood samples alters the results of the BGA. Preanalytical errors were frequently observed in the control group where non-deaerated samples were recorded in 87.3 % but in the intervention group almost all samples (98.9 %) were correctly deaerated. Insufficient homogenization due to omission of manual pivoting was seen in 83.2 % in the control group and in 89.9 % in the intervention group; however, in the intervention group the samples were homogenized automatically during the further analytical process. Although a survey among the staff revealed a high acceptance of the new system and a subjective improvement of workflow, a measurable gain in time after conversion to the new procedure could not be seen. The mean time needed for a complete analysis process until receiving the final results was 244 s in the intervention group and 201 s in the control group. A 10-min delay between taking and analyzing the blood samples led to a significant and clinically relevant elevation of the values for partial pressure of oxygen (pO2) in both groups compared to the results when analyzing the samples immediately (118.4 vs. 148.6 mmHg in the control group and 115.3 vs. 123.7 mmHg in the intervention group). When using standard syringes the partial pressure of carbon dioxide (pCO2) was significantly lower (40.5 vs. 38.3 mmHg) whereas no alterations were seen when using the labeled syringes. The implementation of a new BGA system with labeled syringes and automated processing of the specimens was possible without any difficulties under daily clinical routine conditions in this 10-bed intensive care unit (ICU). A gain of time could not be measured but a reduction in preanalytical errors using the labeled syringes with automated processing was found. Delayed analysis of blood samples can lead to significant changes in pO2 and pCO2 depending on the type of syringe used.
NASA Technical Reports Server (NTRS)
Parker, K. C.; Torian, J. G.
1980-01-01
A sample environmental control and life support model performance analysis using the environmental analysis routines library is presented. An example of a complete model set up and execution is provided. The particular model was synthesized to utilize all of the component performance routines and most of the program options.
2014-09-30
axis and physiological processes driven by the GCs are essential for an individual’s ability to respond and adapt to stress, prolonged elevation of...health assessments. Stress and reproductive hormones (cortisol, aldosterone , thyroid, testosterone, progesterone) have been routinely measured in blood...in South Carolina. Laboratory Analyses Hormone concentrations (cortisol, aldosterone , reproductive and thyroid hormones) in serum samples have
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tholouli, Eleni; MacDermott, Sarah; Hoyland, Judith
2012-08-24
Highlights: Black-Right-Pointing-Pointer Development of a quantitative high throughput in situ expression profiling method. Black-Right-Pointing-Pointer Application to a tissue microarray of 242 AML bone marrow samples. Black-Right-Pointing-Pointer Identification of HOXA4, HOXA9, Meis1 and DNMT3A as prognostic markers in AML. -- Abstract: Measurement and validation of microarray gene signatures in routine clinical samples is problematic and a rate limiting step in translational research. In order to facilitate measurement of microarray identified gene signatures in routine clinical tissue a novel method combining quantum dot based oligonucleotide in situ hybridisation (QD-ISH) and post-hybridisation spectral image analysis was used for multiplex in-situ transcript detection inmore » archival bone marrow trephine samples from patients with acute myeloid leukaemia (AML). Tissue-microarrays were prepared into which white cell pellets were spiked as a standard. Tissue microarrays were made using routinely processed bone marrow trephines from 242 patients with AML. QD-ISH was performed for six candidate prognostic genes using triplex QD-ISH for DNMT1, DNMT3A, DNMT3B, and for HOXA4, HOXA9, Meis1. Scrambled oligonucleotides were used to correct for background staining followed by normalisation of expression against the expression values for the white cell pellet standard. Survival analysis demonstrated that low expression of HOXA4 was associated with poorer overall survival (p = 0.009), whilst high expression of HOXA9 (p < 0.0001), Meis1 (p = 0.005) and DNMT3A (p = 0.04) were associated with early treatment failure. These results demonstrate application of a standardised, quantitative multiplex QD-ISH method for identification of prognostic markers in formalin-fixed paraffin-embedded clinical samples, facilitating measurement of gene expression signatures in routine clinical samples.« less
Fukasawa, Lucila Okuyama; Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares
2017-01-01
The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo's national surveillance for routine diagnosis were selected for this study. The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory's standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer's instructions. The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory's standard methodology, results showed high concordance, with Kappa index ranges of 0.9877-1.00 for CSF, and 0.8004-1.00 for serum samples. The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost.
Liu, Liwei; Zheng, Huaili; Xu, Bincheng; Xiao, Lang; Chigan, Yong; Zhangluo, Yilan
2018-03-01
In this paper, a procedure for in-situ pre-concentration in graphite furnace by repeated sampling and pyrolysis is proposed for the determination of ultra-trace thallium in drinking water by graphite furnace atomic absorption spectrometry (GF-AAS). Without any other laborious enrichment processes that routinely result in analyte loss and contamination, thallium was directly concentrated in the graphite furnace automatically and subsequently subject to analysis. The effects of several key factors, such as the temperature for pyrolysis and atomization, the chemical modifier, and the repeated sampling times were investigated. Under the optimized conditions, a limit of detection of 0.01µgL -1 was obtained, which fulfilled thallium determination in drinking water by GB 5749-2006 regulated by China. Successful analysis of thallium in certified water samples and drinking water samples was demonstrated, with analytical results in good agreement with the certified values and those by inductively coupled plasma mass spectrometry (ICP-MS), respectively. Routine spike-recovery tests with randomly selected drinking water samples showed satisfactory results of 80-96%. The proposed method is simple and sensitive for screening of ultra-trace thallium in drinking water samples. Copyright © 2017. Published by Elsevier B.V.
McNamara, Paula; Humphry, Ruth
2008-05-01
This study obtains a deeper understanding of the processes supporting the formation of young children's routines in a child care classroom. Eight infants and toddlers and their teachers from two child care classrooms were observed for 4 to 6 months during periods of regularly occurring activities. Detailed, moment-to-moment descriptions of their behaviors and interactions were analyzed. Eleven processes supported the development of children's routines. Teachers structured and guided the children's experiences in learning routines, and children initiated requests to do routines. The study also identified three processes where children invited, coached, and modeled, supporting one another in learning routines. Finally, familiar objects used in routines elicited the children's engagement.
Matuszewska, Renata; Szczotko, Maciej; Krogulska, Bozena
2012-01-01
The presence of parasitic protozoa in drinking water is mostly a result of improperly maintened the water treatment process. Currently, in Poland the testing of Cryptosporidium and Giardia in water as a part of routine monitoring of water is not perform. The aim of this study was the optimization of the method of Cryptosporidium and Giardia detection in water according to the main principles of standard ISO 15553:2006 and using Filta-Max xpress automatic elution station. Preliminary tests were performed on the samples contaminated with oocysts and cysts of reference strains of both parasitic protozoa. Further studies were carried out on environmental samples of surface water sampled directly from the intakes of water (21 samples from Vistula River and 8 samples from Zegrzynski Lake). Filtration process and samples volume reducing were performed using an automatic elution system Filta-Max xpress. Next, samples were purified during immunomagnetic separation process (IMS). Isolated cysts and oocysts were stained with FITC and DAPI and than the microscopic observation using an epifluorescence microscope was carried out. Recovery of parasite protozoa in all contaminated water samples after 9-cycles elution process applied was mean 60.6% for Cryptosporidium oocysts and 36.1% for Giardia cysts. Studies on the environmental surface water samples showed the presence of both parasitic protozoa. Number of detected Giardia cysts ranged from 1.0/10 L up to 4.5/10 L in samples from Zegrzynski Lake and from 1.0/10 L up to 38.9/10 L in samples from Vistula River. Cryptosporidium oocysts were present in 50% of samples from the Zegrzynski Lake and in 47.6% of samples from the Vistula River, and their number in both cases was similar and ranged from 0.5 up to 2.5 oocyst/10 L. The results show that applied procedure is appropriate for detection the presence of parasitic protosoan in water, but when water contains much amount of inorganic matter and suspended solids test method have to be modified like subsamples preparation and filtration process speed reduction. The applied method with the modification using Filta-Max xpress system can be useful for the routine monitoring of water. Detection of Cryptosporidium and Giardia in all samples of water taken from the intakes of surface water shows the possibility oftransfering of the protozoan cysts into the water intended for the consumption, therefore the testing of Cryptosporidium and Giardia should be included into the monitoring of water.
Collection fluid helps preservation in voided urine cytology.
Raistrick, J; Shambayati, B; Dunsmuir, W
2008-04-01
Degenerative change caused by delay in processing contributes to false-negative and false-positive diagnosis of urothelial carcinoma in cytology. The aim of the study was to see if the use of a collection fluid for urine samples made a significant difference to urine cytology diagnosis, and if one was better suited for routine use in the hospital laboratory. Three cell collection fluids were evaluated by analysing the preservation and degeneration of cells in urine samples, as was the routine preparation which did not use a collection fluid. In the design study 50 voided urine specimens were taken at random from the hospital haematuria clinic. Three commercially available collection fluids cytolyt, cytospin and cytoRich Blue and the hospital's routine conventional preparation of urine were compared. The degree of degeneration, and so preservation, was assessed by a table of chosen criteria; then ranked and analysed by Friedman's nonparametric test, at P = 0.05. A second table showing the cell content of each slide was also made. These showed no significant diagnostic difference between the collection fluids, but there was a significant difference between the collection fluids and the routine preparation. Minor differences that do not affect diagnosis, such as crystals and ghost red blood cells, were noted in cytospin and cytoRich Blue. It is recommended that a collection fluid is used. This choice should be made after health and safety issues and cost are considered.
Flexible automation of cell culture and tissue engineering tasks.
Knoll, Alois; Scherer, Torsten; Poggendorf, Iris; Lütkemeyer, Dirk; Lehmann, Jürgen
2004-01-01
Until now, the predominant use cases of industrial robots have been routine handling tasks in the automotive industry. In biotechnology and tissue engineering, in contrast, only very few tasks have been automated with robots. New developments in robot platform and robot sensor technology, however, make it possible to automate plants that largely depend on human interaction with the production process, e.g., for material and cell culture fluid handling, transportation, operation of equipment, and maintenance. In this paper we present a robot system that lends itself to automating routine tasks in biotechnology but also has the potential to automate other production facilities that are similar in process structure. After motivating the design goals, we describe the system and its operation, illustrate sample runs, and give an assessment of the advantages. We conclude this paper by giving an outlook on possible further developments.
Advanced Techniques in Pulmonary Function Test Analysis Interpretation and Diagnosis
Gildea, T.J.; Bell, C. William
1980-01-01
The Pulmonary Functions Analysis and Diagnostic System is an advanced clinical processing system developed for use at the Pulmonary Division, Department of Medicine at the University of Nebraska Medical Center. The system generates comparative results and diagnostic impressions for a variety of routine and specialized pulmonary functions test data. Routine evaluation deals with static lung volumes, breathing mechanics, diffusing capacity, and blood gases while specialized tests include lung compliance studies, small airways dysfunction studies and dead space to tidal volume ratios. Output includes tabular results of normal vs. observed values, clinical impressions and commentary and, where indicated, a diagnostic impression. A number of pulmonary physiological and state variables are entered or sampled (A to D) with periodic status reports generated for the test supervisor. Among the various physiological variables sampled are respiratory frequency, minute ventilation, oxygen consumption, carbon dioxide production, and arterial oxygen saturation.
Butler, Christopher C; O'Brien, Kathryn; Wootton, Mandy; Pickles, Timothy; Hood, Kerenza; Howe, Robin; Waldron, Cherry-Ann; Thomas-Jones, Emma; Dudley, Jan; Van Der Voort, Judith; Rumsby, Kate; Little, Paul; Downing, Harriet; Harman, Kim; Hay, Alastair D
2016-04-01
Antibiotic treatment recommendations based on susceptibility data from routinely submitted urine samples may be biased because of variation in sampling, laboratory procedures and inclusion of repeat samples, leading to uncertainty about empirical treatment. To describe and compare susceptibilities of Escherichia coli cultured from routinely submitted samples, with E. coli causing urinary tract infection (UTI) from a cohort of systematically sampled, acutely unwell children. Susceptibilities of 1458 E. coli isolates submitted during the course of routine primary care for children <5 years (routine care samples), compared to susceptibilities of 79 E. coli isolates causing UTI from 5107 children <5 years presenting to primary care with an acute illness [systematic sampling: the Diagnosis of Urinary Tract infection in Young children (DUTY) cohort]. The percentage of E. coli sensitive to antibiotics cultured from routinely submitted samples were as follows: amoxicillin 45.1% (95% confidence interval: 42.5-47.7%); co-amoxiclav using the lower systemic break point (BP) 86.6% (84.7-88.3%); cephalexin 95.1% (93.9-96.1%); trimethoprim 74.0% (71.7-76.2%) and nitrofurantoin 98.2% (97.4-98.8%). The percentage of E. coli sensitive to antibiotics cultured from systematically sampled DUTY urines considered to be positive for UTI were as follows: amoxicillin 50.6% (39.8-61.4%); co-amoxiclav using the systemic BP 83.5% (73.9-90.1%); co-amoxiclav using the urinary BP 94.9% (87.7-98.4%); cephalexin 98.7% (93.2-99.8%); trimethoprim 70.9% (60.1-80.0%); nitrofurantoin 100% (95.3-100.0%) and ciprofloxacin 96.2% (89.4-98.7%). Escherichia coli susceptibilities from routine and systematically obtained samples were similar. Most UTIs in preschool children remain susceptible to nitrofurantoin, co-amoxiclav and cephalexin. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Remotely Controlled Mixers for Light Microscopy Module (LMM) Colloid Samples
NASA Technical Reports Server (NTRS)
Kurk, Michael A. (Andy)
2015-01-01
Developed by NASA Glenn Research Center, the LMM aboard the International Space Station (ISS) is enabling multiple biomedical science experiments. Techshot, Inc., has developed a series of colloid specialty cell systems (C-SPECS) for use in the colloid science experiment module on the LMM. These low-volume mixing devices will enable uniform particle density and remotely controlled repetition of LMM colloid experiments. By automating the experiment process, C-SPECS allow colloid samples to be processed more quickly. In addition, C-SPECS will minimize the time the crew will need to spend on colloid experiments as well as eliminate the need for multiple and costly colloid samples, which are expended after a single examination. This high-throughput capability will lead to more efficient and productive use of the LMM. As commercial launch vehicles begin routine visits to the ISS, C-SPECS could become a significant means to process larger quantities of high-value materials for commercial customers.
Plasma myelin basic protein assay using Gilford enzyme immunoassay cuvettes.
Groome, N P
1981-10-01
The assay of myelin basic protein in body fluids has potential clinical importance as a routine indicator of demyelination. Preliminary details of a competitive enzyme immunoassay for this protein have previously been published by the author (Groome, N. P. (1980) J. Neurochem. 35, 1409-1417). The present paper now describes the adaptation of this assay for use on human plasma and various aspects of routine data processing. A commercially available cuvette system was found to have advantages over microtitre plates but required a permuted arrangement of sample replicates for consistent results. For dose interpolation, the standard curve could be fitted to a three parameter non-linear equation by regression analysis or linearised by the logit/log transformation.
Nilles, M.A.; Gordon, J.D.; Schroder, L.J.; Paulin, C.E.
1995-01-01
The U.S. Geological Survey used four programs in 1991 to provide external quality assurance for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). An intersite-comparison program was used to evaluate onsite pH and specific-conductance determinations. The effects of routine sample handling, processing, and shipping of wet-deposition samples on analyte determinations and an estimated precision of analyte values and concentrations were evaluated in the blind-audit program. Differences between analytical results and an estimate of the analytical precision of four laboratories routinely measuring wet deposition were determined by an interlaboratory-comparison program. Overall precision estimates for the precipitation-monitoring system were determined for selected sites by a collocated-sampler program. Results of the intersite-comparison program indicated that 93 and 86 percent of the site operators met the NADP/NTN accuracy goal for pH determinations during the two intersite-comparison studies completed during 1991. The results also indicated that 96 and 97 percent of the site operators met the NADP/NTN accuracy goal for specific-conductance determinations during the two 1991 studies. The effects of routine sample handling, processing, and shipping, determined in the blind-audit program indicated significant positive bias (a=.O 1) for calcium, magnesium, sodium, potassium, chloride, nitrate, and sulfate. Significant negative bias (or=.01) was determined for hydrogen ion and specific conductance. Only ammonium determinations were not biased. A Kruskal-Wallis test indicated that there were no significant (*3t=.01) differences in analytical results from the four laboratories participating in the interlaboratory-comparison program. Results from the collocated-sampler program indicated the median relative error for cation concentration and deposition exceeded eight percent at most sites, whereas the median relative error for sample volume, sulfate, and nitrate concentration at all sites was less than four percent. The median relative error for hydrogen ion concentration and deposition ranged from 4.6 to 18.3 percent at the four sites and as indicated in previous years of the study, was inversely proportional to the acidity of the precipitation at a given site. Overall, collocated-sampling error typically was five times that of laboratory error estimates for most analytes.
Comparison of routine urinalysis and urine Gram stain for detection of bacteriuria in dogs.
Way, Leilani Ireland; Sullivan, Lauren A; Johnson, Valerie; Morley, Paul S
2013-01-01
To determine the utility of performing urine Gram stain for detection of bacteriuria compared to routine urine sediment examination and bacterial aerobic urine culture. Prospective, observational study. University teaching hospital. Urine samples acquired via cystocentesis through convenience sampling from 103 dogs presenting to a tertiary referral institution. All samples underwent routine urinalysis, including sediment examination, as well as urine Gram stain and quantitative bacterial aerobic urine culture. The urine Gram stain demonstrated improved sensitivity (96% versus 76%), specificity (100% versus 77%), positive predictive value (100% versus 83%), and negative predictive value (93% versus 69%) when identifying bacteriuria, compared to routine urine sediment examination. The urine Gram stain is highly sensitive and specific when detecting the presence of bacteria in canine urine samples. Gram staining should be considered when bacteriuria is highly suspected and requires rapid identification while bacterial culture is pending. © Veterinary Emergency and Critical Care Society 2013.
Lipemia interferences in routine clinical biochemical tests.
Calmarza, Pilar; Cordero, José
2011-01-01
Lipemic specimens are a common and frequent, but yet unresolved problem in clinical chemistry, and may produce significant interferences in the analytical results of different biochemical parameters. The aim of this study was to examine the effect of lipid removal using ultracentrifugation of lipemic samples, on some routine biochemistry parameters. Among all the samples obtained daily in our laboratory, the ones which were visibly muddy were selected and underwent to a process of ultracentrifugation, being determined a variety of biochemical tests before and after ultracentrifugation. A total of 110 samples were studied. We found significant differences in all the parameters studied except for total bilirubin, glucose, gamma-glutamyl transferase (GGT) and aspartate aminotransferase (AST). The greatest differences in the parameters analyzed were found in the concentration of alanine aminotransferase (ALT) (7.36%) and the smallest ones in the concentration of glucose (0.014%). Clinically significant interferences were found for phosphorus, creatinine, total protein and calcium. Lipemia causes clinically significant interferences for phosphorus, creatinine, total protein and calcium measurement and those interferences could be effectively removed by ultracentrifugation.
Methods to improve routine bioassay monitoring for freshly separated, poorly transported plutonium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bihl, D.E.; Lynch, T.P.; Carbaugh, E.H.
1988-09-01
Several human cases involving inhalation of plutonium oxide at Hanford have shown clearance half-times from the lung that are much longer than the 500-day half-time recommended for class Y plutonium in Publication 30 of the International Commission on Radiological Protection(ICRP). The more tenaciously retained material is referred to as super class Y plutonium. The ability to detect super class Y plutonium by current routine bioassay measurements is shown to be poor. Pacific Northwest Laboratory staff involved in the Hanford Internal Dosimetry Program investigated four methods to se if improvements in routine monitoring of workers for fresh super class Y plutoniummore » are feasible. The methods were lung counting, urine sampling, fecal sampling, and use of diethylenetriaminepentaacetate (DTPA) to enhance urinary excretion. Use of DTPA was determined to be not feasible. Routine fecal sampling was found to be feasible but not recommended. Recommendations were made to improve the detection level for routine annual urinalysis and routine annual lung counting. 12 refs., 9 figs., 7 tabs.« less
How to Analyze Routines in Teachers' Thinking Processes during Lesson Planning.
ERIC Educational Resources Information Center
Bromme, Rainer
A justification for the study of teachers' routines, as they affect the preparation of lesson plans, prefaces this paper on teachers' thought processes during lesson planning. In focusing on the importance of research into teachers' routines, it is pointed out that lesson preparation and classroom routines permit teachers to direct attention to…
Antonelli, Giorgia; Padoan, Andrea; Artusi, Carlo; Marinova, Mariela; Zaninotto, Martina; Plebani, Mario
2016-04-01
The aim of this study was to implement in our routine practice an automated saliva preparation protocol for quantification of cortisol (F) and cortisone (E) by LC-MS/MS using a liquid handling platform, maintaining the previously defined reference intervals with the manual preparation. Addition of internal standard solution to saliva samples and calibrators and SPE on μ-elution 96-well plate were performed by liquid handling platform. After extraction, the eluates were submitted to LC-MS/MS analysis. The manual steps within the entire process were to transfer saliva samples in suitable tubes, to put the cap mat and transfer of the collection plate to the LC auto sampler. Transference of the reference intervals from the manual to the automated procedure was established by Passing Bablok regression on 120 saliva samples analyzed simultaneously with the two procedures. Calibration curves were linear throughout the selected ranges. The imprecision ranged from 2 to 10%, with recoveries from 95 to 116%. Passing Bablok regression demonstrated no significant bias. The liquid handling platform translates the manual steps into automated operations allowing for saving hands-on time, while maintaining assay reproducibility and ensuring reliability of results, making it implementable in our routine with the previous established reference intervals. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Effects of Packstock Use and Backpackers on Water Quality in Yosemite National Park, California
NASA Astrophysics Data System (ADS)
Forrester, H.; Clow, D. W.; Roche, J. W.; Heyvaert, A.
2016-12-01
Visitor use, primarily backpacker camping, packstock (horse and mule) trail use, and packstock grazing, in designated Wilderness, increases the potential for negative effects on water quality. To determine the effects of visitor use on water quality in Wilderness in Yosemite National Park, we collected and analyzed surface-water samples for water quality indicators, consisting of fecal indicator bacteria (Escherichia coli), nutrients (nitrogen, phosphorus), suspended sediment concentration (SSC), and hormones (e.g. estrogen compounds) during the summers of 2012-2014. We collected samples upstream and downstream from different types of visitor use at routine intervals (weekly or biweekly) and during storms. Additionally, we sampled upstream and downstream from meadows, and targeted different types of visitor use during a park-wide synoptic sampling campaign (n=63). At packstock stream crossings, statistically significant (P≤0.05) increases in Escherichia coli (E. coli) and SSC occurred downstream from crossings compared to upstream conditions during routine sampling (median difference: 3 CFU 100ml-1, and >0.3 mg l-1, respectively) and during storms (median difference: 32 CFU 100ml-1, and 2.9 mg l-1). At backpacker campsites, during routine sampling, significant increases occurred downstream from backpacker camping for E. coli (median difference: 1 CFU 100ml-1), and estrogen hormones were detected. At packstock grazing areas, which are located in meadows, no significant increases were detected for any of the measured water quality indicators downstream from grazing. Most synoptic sample concentrations were near or below detection limits. Our results indicate that under current use levels: 1) packstock trail use and backpacker camping are associated with detectable effects on water quality, which are most pronounced during storms; 2) increases in water quality indicators were not detected downstream from meadows where packstock were grazed; and 3) environmental processes in meadows provide a valuable ecosystem service by reducing human related sources of microbial contamination.
Instrument to collect fogwater for chemical analysis
NASA Astrophysics Data System (ADS)
Jacob, Daniel J.; Waldman, Jed M.; Haghi, Mehrdad; Hoffmann, Michael R.; Flagan, Richard C.
1985-06-01
An instrument is presented which collects large samples of ambient fogwater by impaction of droplets on a screen. The collection efficiency of the instrument is determined as a function of droplet size, and it is shown that fog droplets in the range 3-100-μm diameter are efficiently collected. No significant evaporation or condensation occurs at any stage of the collection process. Field testing indicates that samples collected are representative of the ambient fogwater. The instrument may easily be automated, and is suitable for use in routine air quality monitoring programs.
Gonçalves, Maria Gisele; Higa, Fábio Takenori; Castilho, Euclides Ayres; Ibarz-Pavón, Ana Belén; Sacchi, Claudio Tavares
2017-01-01
Background The lack of information regarding the burden of acute bacterial meningitis in Latin America leads to a reduction in the estimated incidence rates of the disease, and impairs public health decisions on the use and follow-up of preventive interventions, particularly, the evaluation of existing vaccination policies. The use of the real-time PCR in diagnostic routine procedures has resulted in a substantial increase in confirmed bacterial meningitis cases. However, in resource-poor countries, these assays are only available in reference laboratories. Sample transportation to these laboratories is a critical constraint, as it requires specialized, high cost courier services. To overcome this barrier we evaluated the use of FTATM Elute filter paper cards for the conservation and processing of samples under normal environmental conditions, as they would be when transported from remote and under-equipped healthcare facilities to the reference centers. A total of 401 samples received in 2015 as part of Sao Paulo’s national surveillance for routine diagnosis were selected for this study. Methods The sensitivity and specificity of real-time PCR were evaluated using fresh serum and cerebrospinal fluid (CSF) samples processed using our laboratory’s standard DNA extraction, and processing the same samples after being dried and stored on FTATM card, and DNA extracted following the manufacturer’s instructions. Results The sensitivities for detection of Neisseria meningitidis, Streptococcus pneumoniae, and Haemophilus influenzae from CSF dried and stored on FTATM cards were 98%, 92%, and 100%, respectively, and with serum samples were 73%, 88%, and 100%, respectively. When compared to our laboratory’s standard methodology, results showed high concordance, with Kappa index ranges of 0.9877–1.00 for CSF, and 0.8004–1.00 for serum samples. Conclusion The use of FTATM cards for CSF and serum conservation and transport represents a rapid, reliable, and cost-effective alternative that will allow obtaining valuable epidemiological information that would otherwise be lost. PMID:28235065
NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0006
NASA Technical Reports Server (NTRS)
Gauntner, D. J.; Holdeman, J. D.; Humenik, F. M.
1977-01-01
The NASA Global Atmospheric Sampling Program (GASP) is obtaining measurements of atmospheric trace constituents in the upper troposphere and lower stratosphere using fully automated air sampling systems on board several commercial B-747 aircraft in routine airline service. Atmospheric ozone, and related flight and meteorological data were obtained during 245 flights of a Qantas Airways of Australia B-747 and two Pan American World Airways B-747s from July 1976 through September 1976. In addition, whole air samples, obtained during three flights, were analyzed for trichlorofluoromethane, and filter samples, obtained during four flights, were analyzed for sulfates, nitrates, fluorides, and chlorides. Flight routes and dates, instrumentation, data processing procedures, data tape specifications, and selected analyses are discussed.
von Bargen, Christoph; Brockmeyer, Jens; Humpf, Hans-Ulrich
2014-10-01
Fraudulent blending of food products with meat from undeclared species is a problem on a global scale, as exemplified by the European horse meat scandal in 2013. Routinely used methods such as ELISA and PCR can suffer from limited sensitivity or specificity when processed food samples are analyzed. In this study, we have developed an optimized method for the detection of horse and pork in different processed food matrices using MRM and MRM(3) detection of species-specific tryptic marker peptides. Identified marker peptides were sufficiently stable to resist thermal processing of different meat products and thus allow the sensitive and specific detection of pork or horse in processed food down to 0.24% in a beef matrix system. In addition, we were able to establish a rapid 2-min extraction protocol for the efficient protein extraction from processed food using high molar urea and thiourea buffers. Together, we present here the specific and sensitive detection of horse and pork meat in different processed food matrices using MRM-based detection of marker peptides. Notably, prefractionation of proteins using 2D-PAGE or off-gel fractionation is not necessary. The presented method is therefore easily applicable in analytical routine laboratories without dedicated proteomics background.
Gordon, John D.
1999-01-01
The U.S. Geological Survey operated four external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN) in 1995 and 1996: the intersite-comparison program, the blind-audit program, the interlaboratory- comparison program, and the collocated-sampler program. The intersite-comparison program assessed the precision and bias of pH and specific-conductance determinations made by NADP/NTN site operators. The analytical bias introduced during routine handling, processing, and shipping of wet-deposition samples and precision of analyte values was estimated using a blind-audit program. An interlaboratory-comparison program was used to evaluate differences between analytical results and to estimate the analytical precision of five North American laboratories that routinely analyzed wet deposition. A collocated-sampler program estimated the precision of the overall precipitation collection and analysis system from initial sample collection through final storage of the data. Results of two intersite-comparison studies completed in 1995 indicated 94.6 and 94.4 percent of the onsite pH determinations met the NADP/NTN accuracy goals, whereas 97.2 and 98.3 percent of the specific-conductance determinations were within the established limits. The percentages of onsite determinations that met the accuracy goals in 1996 were slightly less for both pH and specific-conductance than in 1995. In 1996, 93.2 and 87.5 percent of onsite pH determinations met the accuracy goals, whereas the percentage of onsite specific-conductance measurements that met the goals was 93.9 and 94.9 percent.The blind audit program utilizes a paired sample design to evaluate the effects of routine sample handling, processing and shipping on the chemistry of weekly precipitation samples. The portion of the blind audit sample subject to all of the normal onsite handling and processing steps of a regular weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Throughout the report, the term positive bias in regard to blind-audit results indicates that the bucket portion had a higher concentration than the bottle portion. The paired t-test of 1995 blind-audit data indicated that routine sample handling, processing, and shipping introduced a very small positive bias (a=0.05) for hydrogen ion and specific conductance and a slight negative bias (a =0.05) for ammonium and sodium. In 1995, the median paired differences between the bucket and bottle portions ranged from -0.02 milligram per liter for both ammonium and nitrate to +0.002 milligram per liter for calcium. Although the paired t-test indicated a very small positive bias for hydrogen ion, the median paired difference between the bucket and bottle portions was 0.00 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was 0.200 microsiemens per centimeter in 1995. The paired t-test of blind-audit results in 1996 indicated statistically significant bias for 6 of the 10 analytes. Only chloride, nitrate, hydrogen ion, and specific conductance were not biased in 1996. However, the magnitude of the bias in 1996 was very small and only of limited importance from the viewpoint of an analytical chemist or data user. The median paired differences between the bucket and bottle portions ranged from -0.02 milligram per liter for both ammonium and chloride to +0.006 milligram per liter for calcium. For hydrogen ion, the median paired difference between the bucket and bottle portions was -0.357 microequivalent per liter; for specific conductance, the median paired difference between the bucket and bottle portions was 0.00 microsiemens per centimeter in 1996. Surface-chemistry effects due to different amounts of precipitation contacting the sample collection and shipping container surfac
2011-09-30
support the existence of these same stress response pathways in marine mammals. While the HPA axis and physiological processes driven by the GCs are...cortisol, aldosterone , thyroid and reproductive hormones) have been routinely measured in blood as part of the health assessment which also includes a
Kurosaki, Hiromu; Mueller, Rebecca J.; Lambert, Susan B.; ...
2016-07-15
An alternate method of preparing actinide alpha counting sources was developed in place of electrodeposition or lanthanide fluoride micro-precipitation. The method uses lanthanide hydroxide micro-precipitation to avoid the use of hazardous hydrofluoric acid. Lastly, it provides a quicker, simpler, and safer way of preparing actinide alpha counting sources in routine, production-type laboratories that process many samples daily.
Possible Rickettsia massiliae Infection in Greece: an Imported Case.
Chochlakis, Dimosthenis; Bongiorni, Christine; Partalis, Nikolaos; Tselentis, Yannis; Psaroulaki, Anna
2016-07-22
Tick-borne rickettsioses are endemic in Greece; however, until recently, only Rickettsia typhi and R. conorii were tested routinely in human samples arriving at the National Reference Center. During the last few years, the identification of different rickettsia species in ticks led to the introduction of other spotted fever group rickettsiae in routine analysis. Under the new scheme, R. massiliae is now tested routinely in human samples; herein, we describe a human case of this infection.
Førsund, Linn Hege; Kiik, Riina; Skovdahl, Kirsti; Ytrehus, Siri
2016-10-01
To explore and describe how spouses involve themselves in the relationship with their partners with dementia who live in institutional care. Positive reciprocity between partners has been proven to be significant for spouses with partners living with dementia at home. However, little is known about spousal involvement after placement of a partner in an institutional setting. This subject was therefore the focus of this study. Constructivist grounded theory was used to develop meaningful concepts considering the relational processes experienced and described by the spouses. Interviews were conducted with 15 spouses (eight women and seven men ranging in age from 64-90 years) of dementia-afflicted persons living in institutional care. Theoretical sampling, constant comparison and memo-writing guided the data collection and analysis. The analysis showed how the spouses adopted different visiting routines to preserve continuity in their relationship throughout the phases of dementia. Three categories described how these visiting routines were used and adapted along with their partners' dementia progressions in the process of constructing togetherness: 'maintaining involvement and intimacy to preserve continuity in their relationship,' 'structuring visits to facilitate interaction and communication' and 'pursuing moments of mutuality to preserve continuity in a deteriorating relationship.' Being involved and experiencing continuity in the relationship seemed important to the spouses after their partners' placement in institutional care. In the process of constructing togetherness, visiting routines were used to facilitate situations in which they could connect with their partners. These routines were continuously adjusted throughout the phases of dementia. There is a need for a systematic approach to provide sufficient support to spouses throughout their partners' dementia progressions to assist their ongoing involvement. © 2016 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Davis, G. J.
1994-01-01
One area of research of the Information Sciences Division at NASA Ames Research Center is devoted to the analysis and enhancement of processors and advanced computer architectures, specifically in support of automation and robotic systems. To compare systems' abilities to efficiently process Lisp and Ada, scientists at Ames Research Center have developed a suite of non-parallel benchmarks called ELAPSE. The benchmark suite was designed to test a single computer's efficiency as well as alternate machine comparisons on Lisp, and/or Ada languages. ELAPSE tests the efficiency with which a machine can execute the various routines in each environment. The sample routines are based on numeric and symbolic manipulations and include two-dimensional fast Fourier transformations, Cholesky decomposition and substitution, Gaussian elimination, high-level data processing, and symbol-list references. Also included is a routine based on a Bayesian classification program sorting data into optimized groups. The ELAPSE benchmarks are available for any computer with a validated Ada compiler and/or Common Lisp system. Of the 18 routines that comprise ELAPSE, provided within this package are 14 developed or translated at Ames. The others are readily available through literature. The benchmark that requires the most memory is CHOLESKY.ADA. Under VAX/VMS, CHOLESKY.ADA requires 760K of main memory. ELAPSE is available on either two 5.25 inch 360K MS-DOS format diskettes (standard distribution) or a 9-track 1600 BPI ASCII CARD IMAGE format magnetic tape. The contents of the diskettes are compressed using the PKWARE archiving tools. The utility to unarchive the files, PKUNZIP.EXE, is included. The ELAPSE benchmarks were written in 1990. VAX and VMS are trademarks of Digital Equipment Corporation. MS-DOS is a registered trademark of Microsoft Corporation.
Eerola, Susanna; Hollebekkers, Koen; Hallikainen, Anja; Peltonen, Kimmo
2007-02-01
Sample clean-up and HPLC with tandem mass spectrometric detection (LC-MS/MS) was validated for the routine analysis of acrylamide in various foodstuffs. The method used proved to be reliable and the detection limit for routine monitoring was sensitive enough for foods and drinks (38 microg/kg for foods and 5 microg/L for drinks). The RSDs for repeatability and day-to-day variation were below 15% in all food matrices. Two hundred and one samples which included more than 30 different types of food and foods manufactured and prepared in various ways were analysed. The main types of food analysed were potato and cereal-based foods, processed foods (pizza, minced beef meat, meat balls, chicken nuggets, potato-ham casserole and fried bacon) and coffee. Acrylamide was detected at levels, ranging from nondetectable to 1480 microg/kg level in solid food, with crisp bread exhibiting the highest levels. In drinks, the highest value (29 microg/L) was found in regular coffee drinks.
An integrated data-analysis and database system for AMS 14C
NASA Astrophysics Data System (ADS)
Kjeldsen, Henrik; Olsen, Jesper; Heinemeier, Jan
2010-04-01
AMSdata is the name of a combined database and data-analysis system for AMS 14C and stable-isotope work that has been developed at Aarhus University. The system (1) contains routines for data analysis of AMS and MS data, (2) allows a flexible and accurate description of sample extraction and pretreatment, also when samples are split into several fractions, and (3) keeps track of all measured, calculated and attributed data. The structure of the database is flexible and allows an unlimited number of measurement and pretreatment procedures. The AMS 14C data analysis routine is fairly advanced and flexible, and it can be easily optimized for different kinds of measuring processes. Technically, the system is based on a Microsoft SQL server and includes stored SQL procedures for the data analysis. Microsoft Office Access is used for the (graphical) user interface, and in addition Excel, Word and Origin are exploited for input and output of data, e.g. for plotting data during data analysis.
UMTRA Project water sampling and analysis plan, Durango, Colorado. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-09-01
Planned, routine ground water sampling activities at the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Durango, Colorado, are described in this water sampling and analysis plan. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine monitoring stations at the site. The ground water data are used to characterize the site ground water compliance strategies and to monitor contaminants of potential concern identified in the baseline risk assessment (DOE, 1995a). Regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from themore » US EPA regulations in 40 CFR Part 192 (1994) and EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site.« less
Stein, Eric D; White, Bryan P; Mazor, Raphael D; Miller, Peter E; Pilgrim, Erik M
2013-01-01
Molecular methods, such as DNA barcoding, have the potential to enhance biomonitoring programs worldwide. Altering routinely used sample preservation methods to protect DNA from degradation may pose a potential impediment to application of DNA barcoding and metagenomics for biomonitoring using benthic macroinvertebrates. Using higher volumes or concentrations of ethanol, requirements for shorter holding times, or the need to include additional filtering may increase cost and logistical constraints to existing biomonitoring programs. To address this issue we evaluated the efficacy of various ethanol-based sample preservation methods at maintaining DNA integrity. We evaluated a series of methods that were minimally modified from typical field protocols in order to identify an approach that can be readily incorporated into existing monitoring programs. Benthic macroinvertebrates were collected from a minimally disturbed stream in southern California, USA and subjected to one of six preservation treatments. Ten individuals from five taxa were selected from each treatment and processed to produce DNA barcodes from the mitochondrial gene cytochrome c oxidase I (COI). On average, we obtained successful COI sequences (i.e. either full or partial barcodes) for between 93-99% of all specimens across all six treatments. As long as samples were initially preserved in 95% ethanol, successful sequencing of COI barcodes was not affected by a low dilution ratio of 2∶1, transfer to 70% ethanol, presence of abundant organic matter, or holding times of up to six months. Barcoding success varied by taxa, with Leptohyphidae (Ephemeroptera) producing the lowest barcode success rate, most likely due to poor PCR primer efficiency. Differential barcoding success rates have the potential to introduce spurious results. However, routine preservation methods can largely be used without adverse effects on DNA integrity.
Stein, Eric D.; White, Bryan P.; Mazor, Raphael D.; Miller, Peter E.; Pilgrim, Erik M.
2013-01-01
Molecular methods, such as DNA barcoding, have the potential to enhance biomonitoring programs worldwide. Altering routinely used sample preservation methods to protect DNA from degradation may pose a potential impediment to application of DNA barcoding and metagenomics for biomonitoring using benthic macroinvertebrates. Using higher volumes or concentrations of ethanol, requirements for shorter holding times, or the need to include additional filtering may increase cost and logistical constraints to existing biomonitoring programs. To address this issue we evaluated the efficacy of various ethanol-based sample preservation methods at maintaining DNA integrity. We evaluated a series of methods that were minimally modified from typical field protocols in order to identify an approach that can be readily incorporated into existing monitoring programs. Benthic macroinvertebrates were collected from a minimally disturbed stream in southern California, USA and subjected to one of six preservation treatments. Ten individuals from five taxa were selected from each treatment and processed to produce DNA barcodes from the mitochondrial gene cytochrome c oxidase I (COI). On average, we obtained successful COI sequences (i.e. either full or partial barcodes) for between 93–99% of all specimens across all six treatments. As long as samples were initially preserved in 95% ethanol, successful sequencing of COI barcodes was not affected by a low dilution ratio of 2∶1, transfer to 70% ethanol, presence of abundant organic matter, or holding times of up to six months. Barcoding success varied by taxa, with Leptohyphidae (Ephemeroptera) producing the lowest barcode success rate, most likely due to poor PCR primer efficiency. Differential barcoding success rates have the potential to introduce spurious results. However, routine preservation methods can largely be used without adverse effects on DNA integrity. PMID:23308097
Materials and manufacturing processes for increased life/reliability. [of turbine wheels
NASA Technical Reports Server (NTRS)
Duttweiler, R. E.
1977-01-01
Improvements in both quality and durability of disk raw material for both military and commercial engines necessitated an entirely new concept in raw material process control which imposes careful selection, screening and sampling of the basic alloy ingredients, followed by careful monitoring of the melting parameters in all phases of the vacuum melting sequence. Special care is taken to preclude solidification conditions that produce adverse levels of segregation. Melt furnaces are routinely cleaned and inspected for contamination. Ingots are also cleaned and inspected before entering the final melt step.
Anderson, Ruth M
2007-01-01
The success of faculty is, in part, measured by the success of their students. One measurement of student success is passing the National Council Licensure Examination for Registered Nurses. However, some students require assistance beyond routine class work; they require a personalized plan for studying based on individualized areas of weakness. The author reviews the process of implementing a program of individualized student advisement. Included are samples of forms that have been developed to assist in this process.
High-speed AFM and the reduction of tip-sample forces
NASA Astrophysics Data System (ADS)
Miles, Mervyn; Sharma, Ravi; Picco, Loren
High-speed DC-mode AFM has been shown to be routinely capable of imaging at video rate, and, if required, at over 1000 frames per second. At sufficiently high tip-sample velocities in ambient conditions, the tip lifts off the sample surface in a superlubricity process which reduces the level of shear forces imposed on the sample by the tip and therefore reduces the potential damage and distortion of the sample being imaged. High-frequency mechanical oscillations, both lateral and vertical, have been reported to reduced the tip-sample frictional forces. We have investigated the effect of combining linear high-speed scanning with these small amplitude high-frequency oscillations with the aim of reducing further the force interaction in high-speed imaging. Examples of this new version of high-speed AFM imaging will be presented for biological samples.
Digital seismo-acoustic signal processing aboard a wireless sensor platform
NASA Astrophysics Data System (ADS)
Marcillo, O.; Johnson, J. B.; Lorincz, K.; Werner-Allen, G.; Welsh, M.
2006-12-01
We are developing a low power, low-cost wireless sensor array to conduct real-time signal processing of earthquakes at active volcanoes. The sensor array, which integrates data from both seismic and acoustic sensors, is based on Moteiv TMote Sky wireless sensor nodes (www.moteiv.com). The nodes feature a Texas Instruments MSP430 microcontroller, 48 Kbytes of program memory, 10 Kbytes of static RAM, 1 Mbyte of external flash memory, and a 2.4-GHz Chipcon CC2420 IEEE 802.15.4 radio. The TMote Sky is programmed in TinyOS. Basic signal processing occurs on an array of three peripheral sensor nodes. These nodes are tied into a dedicated GPS receiver node, which is focused on time synchronization, and a central communications node, which handles data integration and additional processing. The sensor nodes incorporate dual 12-bit digitizers sampling a seismic sensor and a pressure transducer at 100 samples per second. The wireless capabilities of the system allow flexible array geometry, with a maximum aperture of 200m. We have already developed the digital signal processing routines on board the Moteiv Tmote sensor nodes. The developed routines accomplish Real-time Seismic-Amplitude Measurement (RSAM), Seismic Spectral- Amplitude Measurement (SSAM), and a user-configured Short Term Averaging / Long Term Averaging (STA LTA ratio), which is used to calculate first arrivals. The processed data from individual nodes are transmitted back to a central node, where additional processing may be performed. Such processing will include back azimuth determination and other wave field analyses. Future on-board signal processing will focus on event characterization utilizing pattern recognition and spectral characterization. The processed data is intended as low bandwidth information which can be transmitted periodically and at low cost through satellite telemetry to a web server. The processing is limited by the computational capabilities (RAM, ROM) of the nodes. Nevertheless, we envision this product to be a useful tool for assessing the state of unrest at remote volcanoes.
Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S
2015-01-01
A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the 'EmOC signal functions', a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants' adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining MNH program evaluations in LMICs.
Brenner, Stephan; De Allegri, Manuela; Gabrysch, Sabine; Chinkhumba, Jobiba; Sarker, Malabika; Muula, Adamson S.
2015-01-01
Background A variety of clinical process indicators exists to measure the quality of care provided by maternal and neonatal health (MNH) programs. To allow comparison across MNH programs in low- and middle-income countries (LMICs), a core set of essential process indicators is needed. Although such a core set is available for emergency obstetric care (EmOC), the ‘EmOC signal functions’, a similar approach is currently missing for MNH routine care evaluation. We describe a strategy for identifying core process indicators for routine care and illustrate their usefulness in a field example. Methods We first developed an indicator selection strategy by combining epidemiological and programmatic aspects relevant to MNH in LMICs. We then identified routine care process indicators meeting our selection criteria by reviewing existing quality of care assessment protocols. We grouped these indicators into three categories based on their main function in addressing risk factors of maternal or neonatal complications. We then tested this indicator set in a study assessing MNH quality of clinical care in 33 health facilities in Malawi. Results Our strategy identified 51 routine care processes: 23 related to initial patient risk assessment, 17 to risk monitoring, 11 to risk prevention. During the clinical performance assessment a total of 82 cases were observed. Birth attendants’ adherence to clinical standards was lowest in relation to risk monitoring processes. In relation to major complications, routine care processes addressing fetal and newborn distress were performed relatively consistently, but there were major gaps in the performance of routine care processes addressing bleeding, infection, and pre-eclampsia risks. Conclusion The identified set of process indicators could identify major gaps in the quality of obstetric and neonatal care provided during the intra- and immediate postpartum period. We hope our suggested indicators for essential routine care processes will contribute to streamlining MNH program evaluations in LMICs. PMID:25875252
Molecular methods, such as DNA barcoding, have the potential in enhance biomonitoring programs worldwide. Altering routinely used sample preservation methods to protect DNA from degradation may pose a potential impediment to application of DNA barcoding and metagenomics for biom...
New version of PLNoise: a package for exact numerical simulation of power-law noises
NASA Astrophysics Data System (ADS)
Milotti, Edoardo
2007-08-01
In a recent paper I have introduced a package for the exact simulation of power-law noises and other colored noises [E. Milotti, Comput. Phys. Comm. 175 (2006) 212]: in particular, the algorithm generates 1/f noises with 0<α⩽2. Here I extend the algorithm to generate 1/f noises with 2<α⩽4 (black noises). The method is exact in the sense that it produces a sampled process with a theoretically guaranteed range-limited power-law spectrum for any arbitrary sequence of sampling intervals, i.e. the sampling times may be unevenly spaced. Program summaryTitle of program: PLNoise Catalogue identifier:ADXV_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADXV_v2_0.html Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Programming language used: ANSI C Computer: Any computer with an ANSI C compiler: the package has been tested with gcc version 3.2.3 on Red Hat Linux 3.2.3-52 and gcc version 4.0.0 and 4.0.1 on Apple Mac OS X-10.4 Operating system: All operating systems capable of running an ANSI C compiler RAM: The code of the test program is very compact (about 60 Kbytes), but the program works with list management and allocates memory dynamically; in a typical run with average list length 2ṡ10, the RAM taken by the list is 200 Kbytes External routines: The package needs external routines to generate uniform and exponential deviates. The implementation described here uses the random number generation library ranlib freely available from Netlib [B.W. Brown, J. Lovato, K. Russell: ranlib, available from Netlib, http://www.netlib.org/random/index.html, select the C version ranlib.c], but it has also been successfully tested with the random number routines in Numerical Recipes [W.H. Press, S.A. Teulkolsky, W.T. Vetterling, B.P. Flannery, Numerical Recipes in C: The Art of Scientific Computing, second ed., Cambridge Univ. Press., Cambridge, 1992, pp. 274-290]. Notice that ranlib requires a pair of routines from the linear algebra package LINPACK, and that the distribution of ranlib includes the C source of these routines, in case LINPACK is not installed on the target machine. No. of lines in distributed program, including test data, etc.:2975 No. of bytes in distributed program, including test data, etc.:194 588 Distribution format:tar.gz Catalogue identifier of previous version: ADXV_v1_0 Journal reference of previous version: Comput. Phys. Comm. 175 (2006) 212 Does the new version supersede the previous version?: Yes Nature of problem: Exact generation of different types of colored noise. Solution method: Random superposition of relaxation processes [E. Milotti, Phys. Rev. E 72 (2005) 056701], possibly followed by an integration step to produce noise with spectral index >2. Reasons for the new version: Extension to 1/f noises with spectral index 2<α⩽4: the new version generates both noises with spectral with spectral index 0<α⩽2 and with 2<α⩽4. Summary of revisions: Although the overall structure remains the same, one routine has been added and several changes have been made throughout the code to include the new integration step. Unusual features: The algorithm is theoretically guaranteed to be exact, and unlike all other existing generators it can generate samples with uneven spacing. Additional comments: The program requires an initialization step; for some parameter sets this may become rather heavy. Running time: Running time varies widely with different input parameters, however in a test run like the one in Section 3 in the long write-up, the generation routine took on average about 75 μs for each sample.
Staples, Angela D.; Bates, John E.; Petersen, Isaac T.
2016-01-01
The ability to transition from wakefulness to sleep is one of the most important tasks in the development of sleep during early childhood. Although establishing regular bedtime routines for children with sleep problems can be clinically effective in reducing the number of signaled night awakenings and increasing amounts of sleep, it is unclear whether a regular bedtime routine would be associated with either the frequency of signaled night awakenings or nightly sleep minutes in a non-clinical sample of children. This study examined the role of a regular bedtime routine on the development of sleep regulation and consolidation in a community sample of young children. Adherence to a bedtime routine was concurrently associated with a greater amount of nightly sleep at 36 and 42 months. In addition, adherence to a bedtime routine predicted an increase in nightly sleep minutes over a six-month period. Finally, this study demonstrated that adherence to a bedtime routine was particularly supportive of developmental gains for children of mothers who used consistent parenting practices during the day. PMID:25704740
Mairinger, Fabian D; Walter, Robert Fh; Vollbrecht, Claudia; Hager, Thomas; Worm, Karl; Ting, Saskia; Wohlschläger, Jeremias; Zarogoulidis, Paul; Zarogoulidis, Konstantinos; Schmid, Kurt W
2014-01-01
Isothermal multiple displacement amplification (IMDA) can be a powerful tool in molecular routine diagnostics for homogeneous and sequence-independent whole-genome amplification of notably small tumor samples, eg, microcarcinomas and biopsies containing a small amount of tumor. Currently, this method is not well established in pathology laboratories. We designed a study to confirm the feasibility and convenience of this method for routine diagnostics with formalin-fixed, paraffin-embedded samples prepared by laser-capture microdissection. A total of 250 μg DNA (concentration 5 μg/μL) was generated by amplification over a period of 8 hours with a material input of approximately 25 cells, approximately equivalent to 175 pg of genomic DNA. In the generated DNA, a representation of all chromosomes could be shown and the presence of elected genes relevant for diagnosis in clinical samples could be proven. Mutational analysis of clinical samples could be performed without any difficulty and showed concordance with earlier diagnostic findings. We established the feasibility and convenience of IMDA for routine diagnostics. We also showed that small amounts of DNA, which were not analyzable with current molecular methods, could be sufficient for a wide field of applications in molecular routine diagnostics when they are preamplified with IMDA.
Fuligni, Allison Sidle; Howes, Carollee; Huang, Yiching; Hong, Sandra Soliday; Lara-Cinisomo, Sandraluz
2012-06-01
This paper examines activity settings and daily classroom routines experienced by 3- and 4-year-old low-income children in public center-based preschool programs, private center-based programs, and family child care homes. Two daily routine profiles were identified using a time-sampling coding procedure: a High Free-Choice pattern in which children spent a majority of their day engaged in child-directed free-choice activity settings combined with relatively low amounts of teacher-directed activity, and a Structured-Balanced pattern in which children spent relatively equal proportions of their day engaged in child-directed free-choice activity settings and teacher-directed small- and whole-group activities. Daily routine profiles were associated with program type and curriculum use but not with measures of process quality. Children in Structured-Balanced classrooms had more opportunities to engage in language and literacy and math activities, whereas children in High Free-Choice classrooms had more opportunities for gross motor and fantasy play. Being in a Structured-Balanced classroom was associated with children's language scores but profiles were not associated with measures of children's math reasoning or socio-emotional behavior. Consideration of teachers' structuring of daily routines represents a valuable way to understand nuances in the provision of learning experiences for young children in the context of current views about developmentally appropriate practice and school readiness.
Fuligni, Allison Sidle; Howes, Carollee; Huang, Yiching; Hong, Sandra Soliday; Lara-Cinisomo, Sandraluz
2011-01-01
This paper examines activity settings and daily classroom routines experienced by 3- and 4-year-old low-income children in public center-based preschool programs, private center-based programs, and family child care homes. Two daily routine profiles were identified using a time-sampling coding procedure: a High Free-Choice pattern in which children spent a majority of their day engaged in child-directed free-choice activity settings combined with relatively low amounts of teacher-directed activity, and a Structured-Balanced pattern in which children spent relatively equal proportions of their day engaged in child-directed free-choice activity settings and teacher-directed small- and whole-group activities. Daily routine profiles were associated with program type and curriculum use but not with measures of process quality. Children in Structured-Balanced classrooms had more opportunities to engage in language and literacy and math activities, whereas children in High Free-Choice classrooms had more opportunities for gross motor and fantasy play. Being in a Structured-Balanced classroom was associated with children’s language scores but profiles were not associated with measures of children’s math reasoning or socio-emotional behavior. Consideration of teachers’ structuring of daily routines represents a valuable way to understand nuances in the provision of learning experiences for young children in the context of current views about developmentally appropriate practice and school readiness. PMID:22665945
Neighborhoods and Adolescent Health-Risk Behavior: An Ecological Network Approach1
Browning, Christopher R.; Soller, Brian; Jackson, Aubrey L.
2014-01-01
This study integrates insights from social network analysis, activity space perspectives, and theories of urban and spatial processes to present an innovative approach to neighborhood effects on health-risk behavior among youth. We suggest spatial patterns of neighborhood residents’ non-home routine activities may be conceptualized as ecological, or “eco”-networks, which are two-mode networks that indirectly link residents through socio-spatial overlap in routine activities. We further argue structural configurations of eco-networks are consequential for youth’s behavioral health. In this study we focus on a key structural feature of eco-networks—the neighborhood-level extent to which households share two or more activity locations, or eco-network reinforcement—and its association with two dimensions of health-risk behavior, substance use and delinquency/sexual activity. Using geographic data on non-home routine activity locations among respondents from the Los Angeles Family and Neighborhood Survey (L.A.FANS), we constructed neighborhood-specific eco-networks by connecting sampled households to “activity clusters,” which are sets of spatially-proximate activity locations. We then measured eco-network reinforcement and examined its association with adolescent dimensions of health risk behavior employing a sample of 830 youth ages 12-17 nested in 65 census tracts. We also examined whether neighborhood-level social processes (collective efficacy and intergenerational closure) mediate the association between eco-network reinforcement and the outcomes considered. Results indicated eco-network reinforcement exhibits robust negative associations with both substance use and delinquency/sexual activity scales. Eco-network reinforcement effects were not explained by potential mediating variables. In addition to introducing a novel theoretical and empirical approach to neighborhood effects on youth, our findings highlight the importance of eco-network reinforcement for adolescent behavioral health. PMID:25011958
Gaze, David C; Prante, Christian; Dreier, Jens; Knabbe, Cornelius; Collet, Corinne; Launay, Jean-Marie; Franekova, Janka; Jabor, Antonin; Lennartz, Lieselotte; Shih, Jessie; del Rey, Jose Manuel; Zaninotto, Martina; Plebani, Mario; Collinson, Paul O
2014-06-01
Galectin-3 is secreted from macrophages and binds and activates fibroblasts forming collagen. Tissue fibrosis is central to the progression of chronic heart failure (CHF). We performed a European multicentered evaluation of the analytical performance of the two-step routine and Short Turn-Around-Time (STAT) galectin-3 immunoassay on the ARCHITECT i1000SR, i2000SR, and i4000SR (Abbott Laboratories). We evaluated the assay precision and dilution linearity for both routine and STAT assays and compared serum and plasma, and fresh vs. frozen samples. The reference interval and biological variability were also assessed. Measurable samples were compared between ARCHITECT instruments and between the routine and STAT assays and also to a galectin-3 ELISA (BG Medicine). The total assay coefficient of variation (CV%) was 2.3%-6.2% and 1.7%-7.4% for the routine and STAT assays, respectively. Both assays demonstrated linearity up to 120 ng/mL. Galectin-3 concentrations were higher in plasma samples than in serum samples and correlated well between fresh and frozen samples (R=0.997), between the routine and STAT assays, between the ARCHITECT i1000 and i2000 instruments and with the galectin-3 ELISA. The reference interval on 627 apparently healthy individuals (53% male) yielded upper 95th and 97.5th percentiles of 25.2 and 28.4 ng/mL, respectively. Values were significantly lower in subjects younger than 50 years. The galectin-3 routine and STAT assays on the Abbott ARCHITECT instruments demonstrated good analytical performance. Further clinical studies are required to demonstrate the diagnostic and prognostic potential of this novel marker in patients with CHF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.
During routine maintenance, the coalescers utilized in the Modular Caustic-Side Solvent Extraction Unit (MCU) processing of Salt Batch 6 and a portion of Salt Batch 7 were sampled and submitted to the Savannah River National Laboratory (SRNL) for characterization, for the purpose of identifying solid phase constituents that may be accumulating in these coalescers. Specifically, two samples were received and characterized: A decontaminated salt solution (DSS) coalescer sample and a strip effluent (SE) coalescer sample. Aliquots of the samples were analyzed by XRD, Fourier Transform Infrared (FTIR) Spectroscopy, SEM, and EDS. Other aliquots of the samples were leached in acidmore » solution, and the leachates were analyzed by ICP-AES. In addition, modeling was performed to provide a basis for comparison of the analytical results.« less
A Systematic Evaluation of Blood Serum and Plasma Pre-Analytics for Metabolomics Cohort Studies
Jobard, Elodie; Trédan, Olivier; Postoly, Déborah; André, Fabrice; Martin, Anne-Laure; Elena-Herrmann, Bénédicte; Boyault, Sandrine
2016-01-01
The recent thriving development of biobanks and associated high-throughput phenotyping studies requires the elaboration of large-scale approaches for monitoring biological sample quality and compliance with standard protocols. We present a metabolomic investigation of human blood samples that delineates pitfalls and guidelines for the collection, storage and handling procedures for serum and plasma. A series of eight pre-processing technical parameters is systematically investigated along variable ranges commonly encountered across clinical studies. While metabolic fingerprints, as assessed by nuclear magnetic resonance, are not significantly affected by altered centrifugation parameters or delays between sample pre-processing (blood centrifugation) and storage, our metabolomic investigation highlights that both the delay and storage temperature between blood draw and centrifugation are the primary parameters impacting serum and plasma metabolic profiles. Storing the blood drawn at 4 °C is shown to be a reliable routine to confine variability associated with idle time prior to sample pre-processing. Based on their fine sensitivity to pre-analytical parameters and protocol variations, metabolic fingerprints could be exploited as valuable ways to determine compliance with standard procedures and quality assessment of blood samples within large multi-omic clinical and translational cohort studies. PMID:27929400
Order in the Home: Family Routines Moderate the Impact of Financial Hardship
ERIC Educational Resources Information Center
Budescu, Mia; Taylor, Ronald D.
2013-01-01
The study examined whether frequency of adolescent reported family routines moderated the relation between caregivers' perceptions of financial resources and adolescents' behavioral and academic outcomes among a sample of inner-city African American families. The sample consisted of 115 adolescents (average age = 15.95) and their female caregivers…
Lindblad, M
2007-09-15
Swab sample data from a 13-month microbiological baseline study of swine carcasses at Swedish abattoirs were combined with excision sample data collected routinely at five abattoirs. The aim was to compare the numbers of total aerobic counts, Enterobacteriaceae, and Escherichia coli, recovered by swabbing four carcass sites with gauze (total area 400 cm2) with those obtained by excision at equivalent sites (total area 20 cm2). The results are considered in relation to the process hygiene criteria that are stated in Commission Regulation (EC) No 2073/2005. These criteria apply only to destructive sampling of total aerobic counts and Enterobacteriaceae, but alternative sampling schemes, as well as alternative indicator organisms such as E. coli, are allowed if equivalent guarantees of food safety can be provided. Swab sampling resulted in higher mean log numbers of total aerobic counts at four of the five abattoirs, compared with excision, and lower or equal standard deviations at all abattoirs. The percentage of swab and excision samples positive for Enterobacteriaceae at the different abattoirs ranged from 68 to 100% and 15 to 24%, respectively. Similarly, the percentages of swab samples that were positive for E. coli were higher than the percentages of positive excision samples (range 52 to 84% and 3 to 14%, respectively). Due to the low percentage of positive excision results, the mean log numbers of Enterobacteriaceae and E. coli were only compared at two and one abattoirs, respectively, using log probability regression to substitute censored observations. Higher mean log numbers of Enterobacteriaceae were recovered by swabbing compared with excision at one abattoir, whereas the numbers of Enterobacteriaceae and E. coli did not differ significantly between sampling methods at one abattoir. This study suggests that the same process hygiene criteria as those stipulated for excision can be used for swabbing with gauze without compromising food safety. For monitoring of low numbers of Enterobacteriaceae and E. coli, like those found on swine carcasses at Swedish abattoirs, the results also show that swabbing of a relatively large area is superior to excision of a smaller area.
PLNoise: a package for exact numerical simulation of power-law noises
NASA Astrophysics Data System (ADS)
Milotti, Edoardo
2006-08-01
Many simulations of stochastic processes require colored noises: here I describe a small program library that generates samples with a tunable power-law spectral density: the algorithm can be modified to generate more general colored noises, and is exact for all time steps, even when they are unevenly spaced (as may often happen in the case of astronomical data, see e.g. [N.R. Lomb, Astrophys. Space Sci. 39 (1976) 447]. The method is exact in the sense that it reproduces a process that is theoretically guaranteed to produce a range-limited power-law spectrum 1/f with -1<β⩽1. The algorithm has a well-behaved computational complexity, it produces a nearly perfect Gaussian noise, and its computational efficiency depends on the required degree of noise Gaussianity. Program summaryTitle of program: PLNoise Catalogue identifier:ADXV_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADXV_v1_0.html Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Licensing provisions: none Programming language used: ANSI C Computer: Any computer with an ANSI C compiler: the package has been tested with gcc version 3.2.3 on Red Hat Linux 3.2.3-52 and gcc version 4.0.0 and 4.0.1 on Apple Mac OS X-10.4 Operating system: All operating systems capable of running an ANSI C compiler No. of lines in distributed program, including test data, etc.:6238 No. of bytes in distributed program, including test data, etc.:52 387 Distribution format:tar.gz RAM: The code of the test program is very compact (about 50 Kbytes), but the program works with list management and allocates memory dynamically; in a typical run (like the one discussed in Section 4 in the long write-up) with average list length 2ṡ10, the RAM taken by the list is 200 Kbytes. External routines: The package needs external routines to generate uniform and exponential deviates. The implementation described here uses the random number generation library ranlib freely available from Netlib [B.W. Brown, J. Lovato, K. Russell, ranlib, available from Netlib, http://www.netlib.org/random/index.html, select the C version ranlib.c], but it has also been successfully tested with the random number routines in Numerical Recipes [W.H. Press, S.A. Teulkolsky, W.T. Vetterling, B.P. Flannery, Numerical Recipes in C: The Art of Scientific Computing, second ed., Cambridge Univ. Press, Cambridge, 1992, pp. 274-290]. Notice that ranlib requires a pair of routines from the linear algebra package LINPACK, and that the distribution of ranlib includes the C source of these routines, in case LINPACK is not installed on the target machine. Nature of problem: Exact generation of different types of Gaussian colored noise. Solution method: Random superposition of relaxation processes [E. Milotti, Phys. Rev. E 72 (2005) 056701]. Unusual features: The algorithm is theoretically guaranteed to be exact, and unlike all other existing generators it can generate samples with uneven spacing. Additional comments: The program requires an initialization step; for some parameter sets this may become rather heavy. Running time: Running time varies widely with different input parameters, however in a test run like the one in Section 4 in this work, the generation routine took on average about 7 ms for each sample.
Winter, F H; York, G K; el-Nakhal, H
1971-07-01
A rapid method for estimating the extent of microbial contamination on food and on food processing equipment is described. Microbial cells are rinsed from food or swab samples with sterile diluent and concentrated on the surface of membrane filters. The filters are incubated on a suitable bacteriological medium for 4 hr at 30 C, heated at 105 C for 5 min, and stained. The membranes are then dried at 60 C for 15 min, rendered transparent with immersion oil, and examined microscopically. Data obtained by the rapid method were compared with counts of the same samples determined by the standard plate count method. Over 60 comparisons resulted in a correlation coefficient of 0.906. Because the rapid technique can provide reliable microbiological count information in extremely short times, it can be a most useful tool in the routine evaluation of microbial contamination of food processing facilities and for some foods.
The NOSAMS sample preparation laboratory in the next millenium: Progress after the WOCE program
NASA Astrophysics Data System (ADS)
Gagnon, Alan R.; McNichol, Ann P.; Donoghue, Joanne C.; Stuart, Dana R.; von Reden, Karl; Nosams
2000-10-01
Since 1991, the primary charge of the National Ocean Sciences AMS (NOSAMS) facility at the Woods Hole Oceanographic Institution has been to supply high throughput, high precision AMS 14C analyses for seawater samples collected as part of the World Ocean Circulation Experiment (WOCE). Approximately 13,000 samples taken as part of WOCE should be fully analyzed by the end of Y2K. Additional sample sources and techniques must be identified and incorporated if NOSAMS is to continue in its present operation mode. A trend in AMS today is the ability to routinely process and analyze radiocarbon samples that contain tiny amounts (<100 μg) of carbon. The capability to mass-produce small samples for 14C analysis has been recognized as a major facility goal. The installation of a new 134-position MC-SNICS ion source, which utilizes a smaller graphite target cartridge than presently used, is one step towards realizing this goal. New preparation systems constructed in the sample preparation laboratory (SPL) include an automated bank of 10 small-volume graphite reactors, an automated system to process organic carbon samples, and a multi-dimensional preparative capillary gas chromatograph (PCGC).
Buckley, M G; Marcus, N J; Yacoub, M H
1999-12-01
Brain natriuretic peptide (BNP), atrial natriuretic peptide (ANP) and N-terminal ANP are good research indices of the severity of heart failure. The stability of these peptides at room temperature has become an important factor in assessing their use as indicators of cardiac function in routine clinical practice. Inhibitors such as aprotinin are routinely added in the blood collection process, but may provide no benefit in sample collection and routine clinical practice. We assessed the stability of BNP, ANP and N-terminal ANP in blood samples collected in either the presence or the absence of the protease inhibitor aprotinin. Blood, either with or without aprotinin, was processed immediately (initial; 0 h) and after blood samples had been left for 3 h, 2 days or 3 days at room temperature. These times were chosen to reflect processing in a hospital outpatient clinic (2-3 h), or when posted from general practice (2-3 days). Initial plasma BNP, ANP and N-terminal ANP levels in the absence of aprotinin were 28.2+/-5.4, 44.2+/-7.9 and 1997+/-608 pg/ml respectively, and were not significantly different from initial values in the presence of aprotinin (29.0+/-5.9, 45.2+/-8.0 and 2009+/-579 pg/ml respectively). After 3 h at room temperature, there was a significant fall in ANP in the absence of aprotinin (36. 7+/-7.9 pg/ml; P<0.005), but not in the presence of aprotinin (41. 2+/-7.6 pg/ml). Both BNP and N-terminal ANP were unchanged in either the absence (BNP, 27.6+/-5.5 pg/ml; N-terminal ANP, 2099+/-613 pg/ml) or the presence (BNP, 29.4+/-5.6 pg/ml; N-terminal ANP, 1988+/-600 pg/ml) of aprotinin. After 2 days at room temperature, ANP had fallen significantly in both the absence (16.9+/-3.4 pg/ml) and the presence (24.0+/-5.0 pg/ml) of aprotinin compared with initial values, and there was a significant difference in ANP levels in the absence and presence of aprotinin (P<0.001). ANP levels had decreased further after 3 days at room temperature, to 11.9+/-3.4 pg/ml (no aprotinin) and 20.3+/-5.0 pg/ml (aprotinin added); these values were significantly different (P=0.002). In contrast, there was no change in the levels of BNP or N-terminal ANP after 2 or 3 days at room temperature, in either the absence or the presence of aprotinin. These studies indicate that aprotinin adds little benefit to the stability of cardiac peptides at room temperature. Blood samples for BNP and N-terminal ANP measurement used as a test of heart function in hospital clinics and by general practitioners in the community could be taken into blood tubes containing only EDTA as anticoagulant and without the additional step of adding the routinely used inhibitor aprotinin.
Henderson, Claire; Farrelly, Simone; Flach, Clare; Borschmann, Rohan; Birchwood, Max; Thornicroft, Graham; Waheed, Waquas; Szmukler, George
2017-11-24
In the UK, crisis planning for mental health care should acknowledge the right to make an informed advance treatment refusal under the Mental Capacity Act 2005. Our aims were to estimate the demand for such treatment refusals within a sample of service users who had had a recent hospital admission for psychosis or bipolar disorder, and to examine the relationship between refusals, and service user characteristics. To identify refusals we conducted content analysis of Joint Crisis Plans, which are plans formulated by service users and their clinical team with involvement from an external facilitator, and routine care plans in sub-samples from a multi-centre randomised controlled trial of Joint Crisis Plans (plus routine mental health care) versus routine care alone (CRIMSON) in England. Factors hypothesised to be associated with refusals were identified using the trial data collected through baseline interviews of service users and clinicians and collection of routine clinical data. Ninety-nine of 221 (45%) of the Joint Crisis Plans contained a treatment refusal compared to 10 of 424 (2.4%) baseline routine care plans. No Joint Crisis Plans recorded disagreement with refusals on the part of clinicians. Among those with completed Joint Crisis Plans, adjusted analyses indicated a significant association between treatment refusals and perceived coercion at baseline (odds ratio = 1.21, 95% CI 1.02-1.43), but not with baseline working alliance or a past history of involuntary admission. We demonstrated significant demand for written treatment refusals in line with the Mental Capacity Act 2005, which had not previously been elicited by the process of treatment planning. Future treatment/crisis plans should incorporate the opportunity for service users to record a treatment refusal during the drafting of such plans. ISRCTN11501328 Registered 13th March 2008.
Lucyshyn, Joseph M.; Irvin, Larry K.; Blumberg, E. Richard; Laverty, Robelyn; Horner, Robert H.; Sprague, Jeffrey R.
2015-01-01
We conducted an observational study of parent-child interaction in home activity settings (routines) of families raising young children with developmental disabilities and problem behavior. Our aim was to empirically investigate the construct validity of coercion in typical but unsuccessful family routines. The long-term goal was to develop an expanded ecological unit of analysis that may contribute to sustainable behavioral family intervention. Ten children with autism and/or mental retardation and their families participated. Videotaped observations were conducted in typical but unsuccessful home routines. Parent-child interaction in routines was coded in real time and sequential analyses were conducted to test hypotheses about coercive processes. Following observation, families were interviewed about the social validity of the construct. Results confirmed the presence of statistically significant, attention-driven coercive processes in routines in which parents were occupied with non-child centered tasks. Results partially confirmed the presence of escape-driven coercive processes in routines in which parent demands are common. Additional analysis revealed an alternative pattern with greater magnitude. Family perspectives suggested the social validity of the construct. Results are discussed in terms of preliminary, partial evidence for coercive processes in routines of families of children with developmental disabilities. Implications for behavioral assessment and intervention design are discussed. PMID:26321883
Automated Broad-Range Molecular Detection of Bacteria in Clinical Samples
Hoogewerf, Martine; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.
2016-01-01
Molecular detection methods, such as quantitative PCR (qPCR), have found their way into clinical microbiology laboratories for the detection of an array of pathogens. Most routinely used methods, however, are directed at specific species. Thus, anything that is not explicitly searched for will be missed. This greatly limits the flexibility and universal application of these techniques. We investigated the application of a rapid universal bacterial molecular identification method, IS-pro, to routine patient samples received in a clinical microbiology laboratory. IS-pro is a eubacterial technique based on the detection and categorization of 16S-23S rRNA gene interspace regions with lengths that are specific for each microbial species. As this is an open technique, clinicians do not need to decide in advance what to look for. We compared routine culture to IS-pro using 66 samples sent in for routine bacterial diagnostic testing. The samples were obtained from patients with infections in normally sterile sites (without a resident microbiota). The results were identical in 20 (30%) samples, IS-pro detected more bacterial species than culture in 31 (47%) samples, and five of the 10 culture-negative samples were positive with IS-pro. The case histories of the five patients from whom these culture-negative/IS-pro-positive samples were obtained suggest that the IS-pro findings are highly clinically relevant. Our findings indicate that an open molecular approach, such as IS-pro, may have a high added value for clinical practice. PMID:26763956
Frick, Daniel A; Schuessler, Jan A; von Blanckenburg, Friedhelm
2016-09-28
Stable metal (e.g. Li, Mg, Ca, Fe, Cu, Zn, and Mo) and metalloid (B, Si, Ge) isotope ratio systems have emerged as geochemical tracers to fingerprint distinct physicochemical reactions. These systems are relevant to many Earth Science questions. The benefit of in situ microscale analysis using laser ablation (LA) over bulk sample analysis is to use the spatial context of different phases in the solid sample to disclose the processes that govern their chemical and isotopic compositions. However, there is a lack of in situ analytical routines to obtain a samples' stable isotope ratio together with its chemical composition. Here, we evaluate two novel analytical routines for the simultaneous determination of the chemical and Si stable isotope composition (δ(30)Si) on the micrometre scale in geological samples. In both routines, multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) is combined with femtosecond-LA, where stable isotope ratios are corrected for mass bias using standard-sample-bracketing with matrix-independent calibration. The first method is based on laser ablation split stream (LASS), where the laser aerosol is split and introduced simultaneously into both the MC-ICP-MS and a quadrupole ICP-MS. The second method is based on optical emission spectroscopy using direct observation of the MC-ICP-MS plasma (LA-MC-ICP-MS|OES). Both methods are evaluated using international geological reference materials. Accurate and precise Si isotope ratios were obtained with an uncertainty typically better than 0.23‰, 2SD, δ(30)Si. With both methods major element concentrations (e.g., Na, Al, Si, Mg, Ca) can be simultaneously determined. However, LASS-ICP-MS is superior over LA-MC-ICP-MS|OES, which is limited by its lower sensitivity. Moreover, LASS-ICP-MS offers trace element analysis down to the μg g(-1)-range for more than 28 elements due to lower limits of detection, and with typical uncertainties better than 15%. For in situ simultaneous stable isotope measurement and chemical composition analysis LASS-ICP-MS in combination with MC-ICP-MS is the method of choice. Copyright © 2016 Elsevier B.V. All rights reserved.
Binnicker, Matthew J; Espy, Mark J; Duresko, Brian; Irish, Cole; Mandrekar, Jay
2017-04-01
Recently, automated platforms have been developed that can perform processing, extraction and testing for herpes simplex virus (HSV) nucleic acid on a single instrument. In this study, we compared three commercially-available systems; Aptima ® /Panther (Hologic, San Diego, CA), ARIES ® (Luminex Corporation, Austin, TX), and cobas ® 4800 (Roche Molecular Systems Inc, Pleasanton, CA) for the qualitative detection of HSV-1/2 in clinical samples. Two-hundred seventy-seven specimens (genital [n=193], dermal [n=84]) were submitted for routine HSV-1/2 real-time PCR by a laboratory developed test. Following routine testing, samples were also tested by the Aptima, ARIES, and cobas HSV-1/2 assays per the manufacturer's recommendations. Results were compared to a "consensus standard" defined as the result obtained from ≥3 of the 4 assays. Following testing of 277 specimens, the cobas and ARIES assays demonstrated a sensitivity of 100% for HSV-1 (61/61) and HSV-2 (55/55). The Aptima assays showed a sensitivity of 91.8% (56/61) for HSV-1 and 90.9% (50/55) for HSV-2. Percent specificities for HSV-1 were 96.2% (202/210) by cobas, 99.5% (209/210) by ARIES and 100% (236/236) by Aptima. For HSV-2, the specificities were 98.1% (211/215) by cobas, 99.5% (215/216) by ARIES and 100% (216/216) by Aptima. The turnaround time for testing 24 samples was 2.5h by the cobas 4800, 3.1h by Aptima/Panther, and 3.9h by ARIES. The three commercial systems can perform all current functions on a single platform, thereby improving workflow and potentially reducing errors associated with manual processing of samples. Copyright © 2017 Elsevier B.V. All rights reserved.
2013-09-30
physiological processes driven by the GCs are essential for an individual’s ability to respond and adapt to stress, prolonged elevation of GC hormones...capture-release health assessments. Stress and reproductive hormones (cortisol, aldosterone , thyroid, testosterone, progesterone) have been routinely...ACE) Basin, also in South Carolina. Laboratory Analyses Hormone concentrations (cortisol, aldosterone , reproductive and thyroid hormones) in
A laboratory procedure for measuring and georeferencing soil colour
NASA Astrophysics Data System (ADS)
Marques-Mateu, A.; Balaguer-Puig, M.; Moreno-Ramon, H.; Ibanez-Asensio, S.
2015-04-01
Remote sensing and geospatial applications very often require ground truth data to assess outcomes from spatial analyses or environmental models. Those data sets, however, may be difficult to collect in proper format or may even be unavailable. In the particular case of soil colour the collection of reliable ground data can be cumbersome due to measuring methods, colour communication issues, and other practical factors which lead to a lack of standard procedure for soil colour measurement and georeferencing. In this paper we present a laboratory procedure that provides colour coordinates of georeferenced soil samples which become useful in later processing stages of soil mapping and classification from digital images. The procedure requires a laboratory setup consisting of a light booth and a trichromatic colorimeter, together with a computer program that performs colour measurement, storage, and colour space transformation tasks. Measurement tasks are automated by means of specific data logging routines which allow storing recorded colour data in a spatial format. A key feature of the system is the ability of transforming between physically-based colour spaces and the Munsell system which is still the standard in soil science. The working scheme pursues the automation of routine tasks whenever possible and the avoidance of input mistakes by means of a convenient layout of the user interface. The program can readily manage colour and coordinate data sets which eventually allow creating spatial data sets. All the tasks regarding data joining between colorimeter measurements and samples locations are executed by the software in the background, allowing users to concentrate on samples processing. As a result, we obtained a robust and fully functional computer-based procedure which has proven a very useful tool for sample classification or cataloging purposes as well as for integrating soil colour data with other remote sensed and spatial data sets.
Kocijancic, Marija; Cargonja, Jelena; Delic-Knezevic, Alma
2014-01-01
Preanalytical variables account for most of laboratory errors. There is a wide range of factors that affect the reliability of laboratory report. Most convenient sample type for routine laboratory analysis is serum. BD Vacutainer(®) Rapid Serum Tube (RST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA) blood collection tube provides rapid clotting time allowing fast serum separation. Our aim was to evaluate the comparability of routine chemistry parameters in BD Vacutainer(®) RST blood collection tube in reference with the BD Vacutainer(®) Serum Separating Tubes II Advance Tube (SST) (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). Blood specimens were collected from 90 participants for evaluation on its results, clotting time and stability study of six routine biochemistry parameters: glucose (Glu), aspartate aminotransferase (AST), alanine aminotransferase (ALT), calcium (Ca), lactate dehidrogenase (LD) and potassium (K) measured with Olympus AU2700 analyzer (Beckman Coulter, Tokyo, Japan). The significance of the differences between samples was assessed by paired t-test or Wilcoxon Matched-Pairs Rank test after checking for normality. Clotting process was significantly shorter in the RSTs compared to SSTs (2.49 min vs. 19.47 min, respectively; P < 0.001). There was a statistically significant difference between the RST and SST II tubes for glucose, calcium and LD (P < 0.001). Differences for glucose and LD were also clinically significant. Analyte stability studies showed that all analytes were stable for 24 h at 4 °C. Most results (except LD and glucose) from RST are comparable with those from SST. In addition, RST tube provides shorter clotting time.
Do placebo based validation standards mimic real batch products behaviour? Case studies.
Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E
2011-06-01
Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.
Picchio, Gaston; Vingerhoets, Johan; Tambuyzer, Lotke; Coakley, Eoin; Haddad, Mojgan; Witek, James
2011-12-01
Abstract The prevalence of susceptibility to etravirine was investigated among clinical samples submitted for routine clinical testing in the United States using two separate weighted genotypic scoring systems. The presence of etravirine mutations and susceptibility to etravirine by phenotype of clinical samples from HIV-1-infected patients, submitted to Monogram Biosciences for routine resistance testing between June 2008 and June 2009, were analyzed. Susceptibility by genotype was determined using the Monogram and Tibotec etravirine-weighted genotypic scoring systems, with scores of ≤3 and ≤2, respectively, indicating full susceptibility. Susceptibility by phenotype was determined using the PhenoSense HIV assay, with lower and higher clinical cut-offs of 2.9 and 10, respectively. The frequency of individual etravirine mutations and the impact of the K103N mutation on susceptibility to etravirine by genotype were also determined. Among the 5482 samples with ≥1 defined nonnucleoside reverse transcriptase inhibitor (NNRTI) mutations associated with resistance, 67% were classed as susceptible to etravirine by genotype by both scoring systems. Susceptibility to etravirine by phenotype was higher (76%). The proportion of first-generation NNRTI-resistant samples with (n=3598) and without (n=1884) K103N with susceptibility to etravirine by genotype was 77% and 49%, respectively. Among samples susceptible to first-generation NNRTIs (n=9458), >99% of samples were susceptible to etravirine by phenotype (FC <2.9); the remaining samples had FC ≥2.9-10. In summary, among samples submitted for routine clinical testing in the United States, a high proportion of samples with first-generation NNRTI resistance was susceptible to etravirine by genotype and phenotype. A higher proportion of NNRTI-resistant samples with K103N than without was susceptible to etravirine.
Lombardi, Giovanni; Sansoni, Veronica; Banfi, Giuseppe
2017-08-01
In the last few years, a growing number of molecules have been associated to an endocrine function of the skeletal muscle. Circulating myokine levels, in turn, have been associated with several pathophysiological conditions including the cardiovascular ones. However, data from different studies are often not completely comparable or even discordant. This would be due, at least in part, to the whole set of situations related to the preparation of the patient prior to blood sampling, blood sampling procedure, processing and/or store. This entire process constitutes the pre-analytical phase. The importance of the pre-analytical phase is often not considered. However, in routine diagnostics, the 70% of the errors are in this phase. Moreover, errors during the pre-analytical phase are carried over in the analytical phase and affects the final output. In research, for example, when samples are collected over a long time and by different laboratories, a standardized procedure for sample collecting and the correct procedure for sample storage are acknowledged. In this review, we discuss the pre-analytical variables potentially affecting the measurement of myokines with cardiovascular functions.
Presence of Toxoplasma gondii in Drinking Water from an Endemic Region in Southern Mexico.
Hernandez-Cortazar, Ivonne B; Acosta-Viana, Karla Y; Guzman-Marin, Eugenia; Ortega-Pacheco, Antonio; Segura-Correa, Jose C; Jimenez-Coello, Matilde
2017-05-01
Toxoplasmosis can be acquired through the ingestion of contaminated drinking water with oocysts of Toxoplasma gondii, highly resistant to the routinely disinfection processes; based on chlorination commonly used in the water supply industry. The aim of this study was to determine the presence of T. gondii DNA in samples of public drinking water from an endemic region of southern Mexico. In total 74 samples of water (5 L each) were collected from the three well fields (I, II, and III) and 71 independent wells, distributing public drinking water to the city of Merida Yucatan, after passing through the chlorination process. Water samples were filtered and concentrated by a sucrose solution, then DNA was extracted and evaluated through a nested-PCR (nPCR) specific for T. gondii. Positive samples were detected in 5.4% (4/74) of the water samples. This is the first report of the presence of T. gondii DNA in public drinking water from a large city in southern Mexico, where their consumption without any postpurification treatment could pose a risk for acquiring the infection in the urban population.
Sugden, Karen; Danese, Andrea; Shalev, Idan; Williams, Benjamin S; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for 4, 24, or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-reactive protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried blood spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. We found that K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those found in samples processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data collection conditions that involve processing delays.
32 CFR 701.121 - Processing “routine use” disclosures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... DEPARTMENT OF THE NAVY DOCUMENTS AFFECTING THE PUBLIC DON Privacy Program § 701.121 Processing “routine use... be in writing and state that it is being made under a “routine use” established by a specific PA... and maintain a disclosure accounting of the information released. (See § 701.111.) (b) Failure to cite...
A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bowman, P.
2016-10-03
Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has beenmore » considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.« less
NASA Astrophysics Data System (ADS)
Sydoff, Marie; Stenström, Kristina
2010-04-01
The Department of Physics at Lund University is participating in a European Union project called EUMAPP (European Union Microdose AMS Partnership Programme), in which sample preparation and accelerator mass spectrometry (AMS) measurements of biological samples from microdosing studies have been made. This paper describes a simplified method of converting biological samples to solid graphite for 14C analysis with AMS. The method is based on online combustion of the samples, and reduction of CO 2 in septa-sealed vials. The septa-sealed vials and disposable materials are used to eliminate sample cross-contamination. Measurements of ANU and Ox I standards show deviations of 2% and 3%, respectively, relative to reference values. This level of accuracy is sufficient for biological samples from microdosing studies. Since the method has very few handling steps from sample to graphite, the risk of failure during the sample preparation process is minimized, making the method easy to use in routine preparation of samples.
Pupek, Alex; Matthewson, Beverly; Whitman, Erin; Fullarton, Rachel; Chen, Yu
2017-08-28
The pneumatic tube system (PTS) is commonly used in modern clinical laboratories to provide quick specimen delivery. However, its impact on sample integrity and laboratory testing results are still debatable. In addition, each PTS installation and configuration is unique to its institution. We sought to validate our Swisslog PTS by comparing routine chemistry, hematology, coagulation and blood gas test results and sample integrity indices between duplicate samples transported either manually or by PTS. Duplicate samples were delivered to the core laboratory manually by human courier or via the Swisslog PTS. Head-to-head comparisons of 48 routine chemistry, hematology, coagulation and blood gas laboratory tests, and three sample integrity indices were conducted on 41 healthy volunteers and 61 adult patients. The PTS showed no impact on sample hemolysis, lipemia, or icterus indices (all p<0.05). Although alkaline phosphatase, total bilirubin and hemoglobin reached statistical significance (p=0.009, 0.027 and 0.012, respectively), all had very low average bias which ranged from 0.01% to 2%. Potassium, total hemoglobin and percent deoxyhemoglobin were statistically significant for the neonatal capillary tube study (p=0.011, 0.033 and 0.041, respectively) but no biases greater than ±4% were identified for these parameters. All observed differences of these 48 laboratory tests were not clinically significant. The modern PTS investigated in this study is acceptable for reliable sample delivery for routine chemistry, hematology, coagulation and blood gas (in syringe and capillary tube) laboratory tests.
Holt, Thomas J; Fitzgerald, Sarah; Bossler, Adam M; Chee, Grace; Ng, Esther
2016-04-01
This study utilized routine activity theory to examine the relationships between online behaviors, target suitability, and cyber and mobile phone-based bullying victimization in a nationally representative sample of youth from nine schools across Singapore. Key measures in all three categories-access to technology, online routine behaviors, and target suitability-were significant predictors of both forms of bullying victimization. In particular, females and victims of physical bullying were more likely to experience both forms of victimization. Access to technology and online routine behaviors predicted cyber and mobile phone-based bullying victimization differently. These findings demonstrate that routine activity theory is a viable framework to understand online bullying in non-Western nations, consistent with the existing literature on Western nations. © The Author(s) 2014.
Nunamaker, T R
1983-01-01
This article provides an illustrative application of Data Envelopment Analysis (DEA) methodology to the measurement of routine nursing service efficiency at a group of Wisconsin hospitals. The DEA efficiency ratings and cost savings estimates are then compared to those resulting from application of Medicare's routine cost limitation to the sample data. DEA is also used to determine if any changes in the potential for efficient operations occurred during the 1978-1979 period. Empirical results were representative of the fundamental differences existing between the DEA and cost per patient day approaches. No evidence was found to support the notion that the overall potential for efficient delivery of routine services by the sample institutions was greater in one year than another. PMID:6874357
A prioritization and analysis strategy for environmental surveillance results.
Shyr, L J; Herrera, H; Haaker, R
1997-11-01
DOE facilities are required to conduct environmental surveillance to verify that facility operations are operated within the approved risk envelope and have not caused undue risk to the public and the environment. Given a reduced budget, a strategy for analyzing environmental surveillance data was developed to set priorities for sampling needs. The radiological and metal data collected at Sandia National Laboratories, New Mexico, were used to demonstrate the analysis strategy. Sampling locations were prioritized for further investigation and the needs for routine sampling. The process of data management, analysis, prioritization, and presentation has been automated through a custom-designed computer tool. Data collected over years can be analyzed and summarized in a short table format for prioritization and decision making.
Ethnographic study of ICT-supported collaborative work routines in general practice.
Swinglehurst, Deborah; Greenhalgh, Trisha; Myall, Michelle; Russell, Jill
2010-12-29
Health informatics research has traditionally been dominated by experimental and quasi-experimental designs. An emerging area of study in organisational sociology is routinisation (how collaborative work practices become business-as-usual). There is growing interest in the use of ethnography and other in-depth qualitative approaches to explore how collaborative work routines are enacted and develop over time, and how electronic patient records (EPRs) are used to support collaborative work practices within organisations. Following Feldman and Pentland, we will use 'the organisational routine' as our unit of analysis. In a sample of four UK general practices, we will collect narratives, ethnographic observations, multi-modal (video and screen capture) data, documents and other artefacts, and analyse these to map and compare the different understandings and enactments of three common routines (repeat prescribing, coding and summarising, and chronic disease surveillance) which span clinical and administrative spaces and which, though 'mundane', have an important bearing on quality and safety of care. In a detailed qualitative analysis informed by sociological theory, we aim to generate insights about how complex collaborative work is achieved through the process of routinisation in healthcare organisations. Our study offers the potential not only to identify potential quality failures (poor performance, errors, failures of coordination) in collaborative work routines but also to reveal the hidden work and workarounds by front-line staff which bridge the model-reality gap in EPR technologies and via which "automated" safety features have an impact in practice.
Ethnographic study of ICT-supported collaborative work routines in general practice
2010-01-01
Background Health informatics research has traditionally been dominated by experimental and quasi-experimental designs. An emerging area of study in organisational sociology is routinisation (how collaborative work practices become business-as-usual). There is growing interest in the use of ethnography and other in-depth qualitative approaches to explore how collaborative work routines are enacted and develop over time, and how electronic patient records (EPRs) are used to support collaborative work practices within organisations. Methods/design Following Feldman and Pentland, we will use 'the organisational routine' as our unit of analysis. In a sample of four UK general practices, we will collect narratives, ethnographic observations, multi-modal (video and screen capture) data, documents and other artefacts, and analyse these to map and compare the different understandings and enactments of three common routines (repeat prescribing, coding and summarising, and chronic disease surveillance) which span clinical and administrative spaces and which, though 'mundane', have an important bearing on quality and safety of care. In a detailed qualitative analysis informed by sociological theory, we aim to generate insights about how complex collaborative work is achieved through the process of routinisation in healthcare organisations. Discussion Our study offers the potential not only to identify potential quality failures (poor performance, errors, failures of coordination) in collaborative work routines but also to reveal the hidden work and workarounds by front-line staff which bridge the model-reality gap in EPR technologies and via which "automated" safety features have an impact in practice. PMID:21190583
Mahmmod, Yasser S; Toft, Nils; Katholm, Jørgen; Grønbæk, Carsten; Klaas, Ilka C
2013-11-01
Danish farmers can order a real-time PCR mastitis diagnostic test on routinely taken cow-level samples from milk recordings. Validation of its performance in comparison to conventional mastitis diagnostics under field conditions is essential for efficient control of intramammary infections (IMI) with Staphylococcus aureus (S. aureus). Therefore, the objective of this study was to estimate the sensitivity (Se) and specificity (Sp) of real-time PCR, bacterial culture (BC) and California mastitis test (CMT) for the diagnosis of the naturally occurring IMI with S. aureus in routinely collected milk samples using latent class analysis (LCA) to avoid the assumption of a perfect reference test. Using systematic random sampling, a total of 609 lactating dairy cows were selected from 6 dairy herds with bulk tank milk PCR cycle threshold (Ct) value ≤39 for S. aureus. At routine milk recordings, automatically obtained cow-level (composite) milk samples were analyzed by PCR and at the same milking, 2436 quarter milk samples were collected aseptically for BC and CMT. Results showed that 140 cows (23%) were positive for S. aureus IMI by BC while 170 cows (28%) were positive by PCR. Estimates of Se and Sp for PCR were higher than test estimates of BC and CMT. SeCMT was higher than SeBC however, SpBC was higher than SpCMT. SePCR was 91%, while SeBC was 53%, and SeCMT was 61%. SpPCR was 99%, while SpBC was 89%, and SpCMT was 65%. In conclusion, PCR has a higher performance than the conventional diagnostic tests (BC and CMT) suggesting its usefulness as a routine test for accurate diagnosis of S. aureus IMI from dairy cows at routine milk recordings. The use of LCA provided estimates of the test characteristics for two currently diagnostic tests (BC, CMT) and a novel technique (real-time PCR) for diagnosing S. aureus IMI under field conditions at routine milk recordings in Denmark. Copyright © 2013 Elsevier B.V. All rights reserved.
Study to determine cloud motion from meteorological satellite data
NASA Technical Reports Server (NTRS)
Clark, B. B.
1972-01-01
Processing techniques were tested for deducing cloud motion vectors from overlapped portions of pairs of pictures made from meteorological satellites. This was accomplished by programming and testing techniques for estimating pattern motion by means of cross correlation analysis with emphasis placed upon identifying and reducing errors resulting from various factors. Techniques were then selected and incorporated into a cloud motion determination program which included a routine which would select and prepare sample array pairs from the preprocessed test data. The program was then subjected to limited testing with data samples selected from the Nimbus 4 THIR data provided by the 11.5 micron channel.
Le Quellec, Sandra; Paris, Mickaël; Nougier, Christophe; Sobas, Frédéric; Rugeri, Lucia; Girard, Sandrine; Bordet, Jean-Claude; Négrier, Claude; Dargaud, Yesim
2017-05-01
Pneumatic tube system (PTS) in hospitals is commonly used for the transport of blood samples to clinical laboratories, as it is rapid and cost-effective. The aim was to compare the effects on haematology samples of a newly acquired ~2km-long PTS that links 2 hospitals with usual transport (non-pneumatic tube system, NPTS). Complete blood cell count, routine coagulation assays, platelet function tests (PFT) with light-transmission aggregometry and global coagulation assays including ROTEM® and thrombin generation assay (TGA) were performed on blood samples from 30 healthy volunteers and 9 healthy volunteers who agreed to take aspirin prior to blood sampling. The turnaround time was reduced by 31% (p<0.001) with the use of PTS. No statistically significant difference was observed for most routine haematology assays including PFT, and ROTEM® analysis. A statistically significant, but not clinically relevant, shortening of the APTT after sample transport by PTS was found (mean±SD: 30s±1.8 vs. 29.5s±2.1 for NPTS). D-dimer levels were 7.4% higher after transport through PTS but were not discordant. A statistically significant increase of thrombin generation was found in both platelet poor- and platelet rich- plasma samples after PTS transport compared to NPTS transport. PTS is suitable for the transport of samples prior to routine haematology assays including PFT, but should not be used for samples intended for thrombin generation measurement. Copyright © 2017 Elsevier Ltd. All rights reserved.
Series: Pragmatic trials and real world evidence: Paper 8. Data collection and management.
Meinecke, Anna-Katharina; Welsing, Paco; Kafatos, George; Burke, Des; Trelle, Sven; Kubin, Maria; Nachbaur, Gaelle; Egger, Matthias; Zuidgeest, Mira
2017-11-01
Pragmatic trials can improve our understanding of how treatments will perform in routine practice. In a series of eight papers, the GetReal Consortium has evaluated the challenges in designing and conducting pragmatic trials and their specific methodological, operational, regulatory, and ethical implications. The present final paper of the series discusses the operational and methodological challenges of data collection in pragmatic trials. A more pragmatic data collection needs to balance the delivery of highly accurate and complete data with minimizing the level of interference that data entry and verification induce with clinical practice. Furthermore, it should allow for the involvement of a representative sample of practices, physicians, and patients who prescribe/receive treatment in routine care. This paper discusses challenges that are related to the different methods of data collection and presents potential solutions where possible. No one-size-fits-all recommendation can be given for the collection of data in pragmatic trials, although in general the application of existing routinely used data-collection systems and processes seems to best suit the pragmatic approach. However, data access and privacy, the time points of data collection, the level of detail in the data, and the lack of a clear understanding of the data-collection process were identified as main challenges for the usage of routinely collected data in pragmatic trials. A first step should be to determine to what extent existing health care databases provide the necessary study data and can accommodate data collection and management. When more elaborate or detailed data collection or more structured follow-up is required, data collection in a pragmatic trial will have to be tailor-made, often using a hybrid approach using a dedicated electronic case report form (eCRF). In this case, the eCRF should be kept as simple as possible to reduce the burden for practitioners and minimize influence on routine clinical practice. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Berman, A. L.
1977-01-01
An algorithm was developed for the continuous and automatic computation of Doppler noise concurrently at four sample rate intervals, evenly spanning three orders of magnitude. Average temporal Doppler phase fluctuation spectra will be routinely available in the DSN tracking system Mark III-77 and require little additional processing. The basic (noise) data will be extracted from the archival tracking data file (ATDF) of the tracking data management system.
Isolation of Clostridium spiroforme from rabbits.
Holmes, H T; Sonn, R J; Patton, N M
1988-04-01
The isolation of Clostridium spiroforme from intestinal contents of rabbits was achieved by sampling the supernatant-pellet interphase of centrifuged specimens processed for routine toxin analysis. High-speed centrifugation at 20,000x for 15 minutes provided a rapid and effective means of separating this anaerobic pathogen from the majority of both indigenous and non-indigenous intestinal microbial flora. The unusual helically-coiled, semicircular shape of the microorganism is considered, at least in part, responsible for this phenomenon.
How Postpartum Women With Depressive Symptoms Manage Sleep Disruption and Fatigue.
Doering, Jennifer J; Sims, Dauphne A; Miller, Donald D
2017-04-01
Postpartum sleep and fatigue have bidirectional relationships with depressive symptoms and challenge women's everyday functioning. The everyday process of managing postpartum sleep and fatigue in the context of depressive symptoms remains unexplored. We conducted a grounded theory study with a sample of 19 women who screened positive on the Postpartum Depression Screening Scale (PDSS™) Short Form at 3 weeks postpartum. Women completed semi-structured in-home interviews and the full PDSS and Modified Fatigue Symptoms Checklist at 1, 3, and 6 months postpartum. The sample was on average 27 years old, with 2.8 children, and 63% were African-American. They described a basic social process of Finding a Routine Together, during which women's experiences with their infants progressed from Retreating at month 1 toward Finding a New Normal at month 6. In their work to Find a Routine Together, mothers' patterns of change over time were continuous, gradual, or prolonged. Their progress was influenced by depressive symptoms, social support, work and daycare, stability in social circumstances, and underlying stressors. This study's findings suggest the need to allocate resources and tailor interventions to meet the needs of women who are most vulnerable to the health effects of ongoing persistent severe fatigue, disordered sleep, and sub-clinical and clinical levels of depressive symptoms. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Validation of a One-Step Method for Extracting Fatty Acids from Salmon, Chicken and Beef Samples.
Zhang, Zhichao; Richardson, Christine E; Hennebelle, Marie; Taha, Ameer Y
2017-10-01
Fatty acid extraction methods are time-consuming and expensive because they involve multiple steps and copious amounts of extraction solvents. In an effort to streamline the fatty acid extraction process, this study compared the standard Folch lipid extraction method to a one-step method involving a column that selectively elutes the lipid phase. The methods were tested on raw beef, salmon, and chicken. Compared to the standard Folch method, the one-step extraction process generally yielded statistically insignificant differences in chicken and salmon fatty acid concentrations, percent composition and weight percent. Initial testing showed that beef stearic, oleic and total fatty acid concentrations were significantly lower by 9-11% with the one-step method as compared to the Folch method, but retesting on a different batch of samples showed a significant 4-8% increase in several omega-3 and omega-6 fatty acid concentrations with the one-step method relative to the Folch. Overall, the findings reflect the utility of a one-step extraction method for routine and rapid monitoring of fatty acids in chicken and salmon. Inconsistencies in beef concentrations, although minor (within 11%), may be due to matrix effects. A one-step fatty acid extraction method has broad applications for rapidly and routinely monitoring fatty acids in the food supply and formulating controlled dietary interventions. © 2017 Institute of Food Technologists®.
EVALUATION OF REGISTRATION, COMPRESSION AND CLASSIFICATION ALGORITHMS
NASA Technical Reports Server (NTRS)
Jayroe, R. R.
1994-01-01
Several types of algorithms are generally used to process digital imagery such as Landsat data. The most commonly used algorithms perform the task of registration, compression, and classification. Because there are different techniques available for performing registration, compression, and classification, imagery data users need a rationale for selecting a particular approach to meet their particular needs. This collection of registration, compression, and classification algorithms was developed so that different approaches could be evaluated and the best approach for a particular application determined. Routines are included for six registration algorithms, six compression algorithms, and two classification algorithms. The package also includes routines for evaluating the effects of processing on the image data. This collection of routines should be useful to anyone using or developing image processing software. Registration of image data involves the geometrical alteration of the imagery. Registration routines available in the evaluation package include image magnification, mapping functions, partitioning, map overlay, and data interpolation. The compression of image data involves reducing the volume of data needed for a given image. Compression routines available in the package include adaptive differential pulse code modulation, two-dimensional transforms, clustering, vector reduction, and picture segmentation. Classification of image data involves analyzing the uncompressed or compressed image data to produce inventories and maps of areas of similar spectral properties within a scene. The classification routines available include a sequential linear technique and a maximum likelihood technique. The choice of the appropriate evaluation criteria is quite important in evaluating the image processing functions. The user is therefore given a choice of evaluation criteria with which to investigate the available image processing functions. All of the available evaluation criteria basically compare the observed results with the expected results. For the image reconstruction processes of registration and compression, the expected results are usually the original data or some selected characteristics of the original data. For classification processes the expected result is the ground truth of the scene. Thus, the comparison process consists of determining what changes occur in processing, where the changes occur, how much change occurs, and the amplitude of the change. The package includes evaluation routines for performing such comparisons as average uncertainty, average information transfer, chi-square statistics, multidimensional histograms, and computation of contingency matrices. This collection of routines is written in FORTRAN IV for batch execution and has been implemented on an IBM 360 computer with a central memory requirement of approximately 662K of 8 bit bytes. This collection of image processing and evaluation routines was developed in 1979.
Gassas, Adam; Krueger, Joerg; Alvi, Saima; Sung, Lillian; Hitzler, Johanne; Lieberman, Lani
2014-12-01
Despite the success of central nervous system (CNS) directed therapy in pediatric acute lymphoblastic leukemia (ALL), relapse involving the CNS continues to be observed in 5-10% of children when utilizing standard intrathecal prophylactic chemotherapy. While most pediatric ALL treatment protocols mandate regular lumbar punctures (LP) for the intrathecal injection of chemotherapy, the value of routine cytological analysis of cerebrospinal fluid (CSF) during therapy is unknown. Our objective was to assess the diagnostic value of routine CSF analysis during ALL therapy. To allow for at least 10 years of follow up from ALL diagnosis, children (0-18 years) with ALL diagnosed and treated at SickKids, Toronto, Canada between 1994-2004 were studied. Medical records of patients with CNS relapse were examined to determine whether CNS relapse was diagnosed based on cytology of a routinely obtained CSF sample, a CSF sample obtained because of signs and symptoms or a CSF sample obtained after the diagnosis of a bone marrow relapse. Of 494 children treated for ALL, 31 (6.6%) developed a relapse of ALL involving the CNS. Twenty-two had an isolated CNS relapse and nine had a combined bone marrow and CNS relapse. Among patients with isolated CNS relapse, 73% (16/22) were diagnosed based on routine CSF samples obtained from asymptomatic children. Conversely, 89% (8/9) of children with combined bone marrow and CNS relapse presented with symptoms and signs that prompted CSF examination. Routine CSF examination at the time of LP for intrathecal chemotherapy is useful in detecting CNS relapse. © 2014 Wiley Periodicals, Inc.
Implementing a laboratory automation system: experience of a large clinical laboratory.
Lam, Choong Weng; Jacob, Edward
2012-02-01
Laboratories today face increasing pressure to automate their operations as they are challenged by a continuing increase in workload, need to reduce expenditure, and difficulties in recruitment of experienced technical staff. Was the implementation of a laboratory automation system (LAS) in the Clinical Biochemistry Laboratory at Singapore General Hospital successful? There is no simple answer, so the following topics comparing and contrasting pre- and post-LAS have been explored: turnaround time (TAT), laboratory errors, and staff satisfaction. The benefits and limitations of LAS from the laboratory experience were also reviewed. The mean TAT for both stat and routine samples decreased post-LAS (30% and 13.4%, respectively). In the 90th percentile TAT chart, a 29% reduction was seen in the processing of stat samples on the LAS. However, no significant difference in the 90th percentile TAT was observed with routine samples. It was surprising to note that laboratory errors increased post-LAS. Considerable effort was needed to overcome the initial difficulties associated with adjusting to a new system, new software, and new working procedures. Although some of the known advantages and limitations of LAS have been validated, the claimed benefits such as improvements in TAT, laboratory errors, and staff morale were not evident in the initial months.
Micro-balance sensor integrated with atomic layer deposition chamber
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinson, Alex B. F.; Libera, Joseph A.; Elam, Jeffrey W.
The invention is directed to QCM measurements in monitoring ALD processes. Previously, significant barriers remain in the ALD processes and accurate execution. To turn this exclusively dedicated in situ technique into a routine characterization method, an integral QCM fixture was developed. This new design is easily implemented on a variety of ALD tools, allows rapid sample exchange, prevents backside deposition, and minimizes both the footprint and flow disturbance. Unlike previous QCM designs, the fast thermal equilibration enables tasks such as temperature-dependent studies and ex situ sample exchange, further highlighting the feasibility of this QCM design for day-to-day use. Finally, themore » in situ mapping of thin film growth rates across the ALD reactor was demonstrated in a popular commercial tool operating in both continuous and quasi-static ALD modes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Fink, S. D.
Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), and Caustic Wash Tank (CWT) samples from several of the ?microbatches? of Integrated Salt Disposition Project (ISDP) Salt Batch (?Macrobatch?) 4 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by inductively-coupled plasma emission spectroscopy (ICPES). Furthermore, samples from the CWT have been analyzed by a variety of methods to investigate a decline in the decontamination factor (DF) of the cesium observed at MCU. The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and themore » previous set of results for Macrobatch 3 samples indicate generally consistent operations. There is no indication of a disruption in plutonium and strontium removal. The average cesium DF and concentration factor (CF) for samples obtained from Macrobatch 4 are slightly lower than for Macrobatch 3, but still well within operating parameters. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in Actinide Removal Process (ARP).« less
NASA Astrophysics Data System (ADS)
Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena
2018-04-01
The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.
Improving preanalytic processes using the principles of lean production (Toyota Production System).
Persoon, Thomas J; Zaleski, Sue; Frerichs, Janice
2006-01-01
The basic technologies used in preanalytic processes for chemistry tests have been mature for a long time, and improvements in preanalytic processes have lagged behind improvements in analytic and postanalytic processes. We describe our successful efforts to improve chemistry test turnaround time from a central laboratory by improving preanalytic processes, using existing resources and the principles of lean production. Our goal is to report 80% of chemistry tests in less than 1 hour and to no longer recognize a distinction between expedited and routine testing. We used principles of lean production (the Toyota Production System) to redesign preanalytic processes. The redesigned preanalytic process has fewer steps and uses 1-piece flow to move blood samples through the accessioning, centrifugation, and aliquoting processes. Median preanalytic processing time was reduced from 29 to 19 minutes, and the laboratory met the goal of reporting 80% of chemistry results in less than 1 hour for 11 consecutive months.
MMX-I: A data-processing software for multi-modal X-ray imaging and tomography
NASA Astrophysics Data System (ADS)
Bergamaschi, A.; Medjoubi, K.; Messaoudi, C.; Marco, S.; Somogyi, A.
2017-06-01
Scanning hard X-ray imaging allows simultaneous acquisition of multimodal information, including X-ray fluorescence, absorption, phase and dark-field contrasts, providing structural and chemical details of the samples. Combining these scanning techniques with the infrastructure developed for fast data acquisition at Synchrotron Soleil permits to perform multimodal imaging and tomography during routine user experiments at the Nanoscopium beamline. A main challenge of such imaging techniques is the online processing and analysis of the generated very large volume (several hundreds of Giga Bytes) multimodal data-sets. This is especially important for the wide user community foreseen at the user oriented Nanoscopium beamline (e.g. from the fields of Biology, Life Sciences, Geology, Geobiology), having no experience in such data-handling. MMX-I is a new multi-platform open-source freeware for the processing and reconstruction of scanning multi-technique X-ray imaging and tomographic datasets. The MMX-I project aims to offer, both expert users and beginners, the possibility of processing and analysing raw data, either on-site or off-site. Therefore we have developed a multi-platform (Mac, Windows and Linux 64bit) data processing tool, which is easy to install, comprehensive, intuitive, extendable and user-friendly. MMX-I is now routinely used by the Nanoscopium user community and has demonstrated its performance in treating big data.
Factors Related to Women's Childbirth Satisfaction in Physiologic and Routine Childbirth Groups
Jafari, Elham; Mohebbi, Parvin; Mazloomzadeh, Saeideh
2017-01-01
Background: Women's satisfaction with childbirth is an important measure of the quality of maternity care services. This study aims to address factors related to women's childbirth satisfaction in physiological and routine childbirth groups. Materials and Methods: This descriptive-analytical study was conducted among 340 women in physiological and routine childbirth groups in 2012. Women were selected through convenience sampling method in the routine group and by census in the physiological group. Data were collected using a 5-part questionnaire composed of demographic and obstetrics details, Mackey's Childbirth Satisfaction Rating Scale (CSRS), satisfied with birth setting, Labor Agentry Scale (LAS), and Visual Analogue Scale (VAS), which was completed by interview 24 hours after childbirth. Data were analyzed using the Statistical Package for the Social Sciences version 18 software using Pearson correlation test, independent t-test, analysis of variance, and linear, multivariate regression model at the significant level of P < 0.05. Results: In both the physiological and routine childbirth groups, satisfaction was found related to the severity of pain (P < 0.05), self-control (P < 0.0001), and birth setting satisfaction (P < 0.0001). In the physiological group, satisfaction was significantly related to previous knowledge of childbirth (P = 0.024), attitude toward the recent pregnancy (P = 0.007), and perceived severity of pain (P = 0.016). However, in the routine group, satisfaction was related only to intentional pregnancy (P = 0.002). In neither group, satisfaction was related to demographic characteristics, maternal parity, and participation in pregnancy and childbirth classes or maternal feelings toward the onset of childbirth (P > 0.05). Conclusions: Improved physical structure and setting of birth room, nonmedical pain relief, mothers' involvement in the process of labor, and sense of being in control are associated with mothers' satisfaction. PMID:28706547
Factors Related to Women's Childbirth Satisfaction in Physiologic and Routine Childbirth Groups.
Jafari, Elham; Mohebbi, Parvin; Mazloomzadeh, Saeideh
2017-01-01
Women's satisfaction with childbirth is an important measure of the quality of maternity care services. This study aims to address factors related to women's childbirth satisfaction in physiological and routine childbirth groups. This descriptive-analytical study was conducted among 340 women in physiological and routine childbirth groups in 2012. Women were selected through convenience sampling method in the routine group and by census in the physiological group. Data were collected using a 5-part questionnaire composed of demographic and obstetrics details, Mackey's Childbirth Satisfaction Rating Scale (CSRS), satisfied with birth setting, Labor Agentry Scale (LAS), and Visual Analogue Scale (VAS), which was completed by interview 24 hours after childbirth. Data were analyzed using the Statistical Package for the Social Sciences version 18 software using Pearson correlation test, independent t -test, analysis of variance, and linear, multivariate regression model at the significant level of P < 0.05. In both the physiological and routine childbirth groups, satisfaction was found related to the severity of pain ( P < 0.05), self-control ( P < 0.0001), and birth setting satisfaction ( P < 0.0001). In the physiological group, satisfaction was significantly related to previous knowledge of childbirth ( P = 0.024), attitude toward the recent pregnancy ( P = 0.007), and perceived severity of pain ( P = 0.016). However, in the routine group, satisfaction was related only to intentional pregnancy ( P = 0.002). In neither group, satisfaction was related to demographic characteristics, maternal parity, and participation in pregnancy and childbirth classes or maternal feelings toward the onset of childbirth ( P > 0.05). Improved physical structure and setting of birth room, nonmedical pain relief, mothers' involvement in the process of labor, and sense of being in control are associated with mothers' satisfaction.
Towards a routine application of Top-Down approaches for label-free discovery workflows.
Schmit, Pierre-Olivier; Vialaret, Jerome; Wessels, Hans J C T; van Gool, Alain J; Lehmann, Sylvain; Gabelle, Audrey; Wood, Jason; Bern, Marshall; Paape, Rainer; Suckau, Detlev; Kruppa, Gary; Hirtz, Christophe
2018-03-20
Thanks to proteomics investigations, our vision of the role of different protein isoforms in the pathophysiology of diseases has largely evolved. The idea that protein biomarkers like tau, amyloid peptides, ApoE, cystatin, or neurogranin are represented in body fluids as single species is obviously over-simplified, as most proteins are present in different isoforms and subjected to numerous processing and post-translational modifications. Measuring the intact mass of proteins by MS has the advantage to provide information on the presence and relative amount of the different proteoforms. Such Top-Down approaches typically require a high degree of sample pre-fractionation to allow the MS system to deliver optimal performance in terms of dynamic range, mass accuracy and resolution. In clinical studies, however, the requirements for pre-analytical robustness and sample size large enough for statistical power restrict the routine use of a high degree of sample pre-fractionation. In this study, we have investigated the capacities of current-generation Ultra-High Resolution Q-Tof systems to deal with high complexity intact protein samples and have evaluated the approach on a cohort of patients suffering from neurodegenerative disease. Statistical analysis has shown that several proteoforms can be used to distinguish Alzheimer disease patients from patients suffering from other neurodegenerative disease. Top-down approaches have an extremely high biological relevance, especially when it comes to biomarker discovery, but the necessary pre-fractionation constraints are not easily compatible with the robustness requirements and the size of clinical sample cohorts. We have demonstrated that intact protein profiling studies could be run on UHR-Q-ToF with limited pre-fractionation. The proteoforms that have been identified as candidate biomarkers in the-proof-of concept study are derived from proteins known to play a role in the pathophysiology process of Alzheimer disease. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tian, Z; Folkerts, M; Jiang, S
Purpose: We have previously developed a GPU-OpenCL-based MC dose engine named goMC with built-in analytical linac beam model. To move goMC towards routine clinical use, we have developed an automatic beam-commissioning method, and an efficient source sampling strategy to facilitate dose calculations for real treatment plans. Methods: Our commissioning method is to automatically adjust the relative weights among the sub-sources, through an optimization process minimizing the discrepancies between calculated dose and measurements. Six models built for Varian Truebeam linac photon beams (6MV, 10MV, 15MV, 18MV, 6MVFFF, 10MVFFF) were commissioned using measurement data acquired at our institution. To facilitate dose calculationsmore » for real treatment plans, we employed inverse sampling method to efficiently incorporate MLC leaf-sequencing into source sampling. Specifically, instead of sampling source particles control-point by control-point and rejecting the particles blocked by MLC, we assigned a control-point index to each sampled source particle, according to MLC leaf-open duration of each control-point at the pixel where the particle intersects the iso-center plane. Results: Our auto-commissioning method decreased distance-to-agreement (DTA) of depth dose at build-up regions by 36.2% averagely, making it within 1mm. Lateral profiles were better matched for all beams, with biggest improvement found at 15MV for which root-mean-square difference was reduced from 1.44% to 0.50%. Maximum differences of output factors were reduced to less than 0.7% for all beams, with largest decrease being from1.70% to 0.37% found at 10FFF. Our new sampling strategy was tested on a Head&Neck VMAT patient case. Achieving clinically acceptable accuracy, the new strategy could reduce the required history number by a factor of ∼2.8 given a statistical uncertainty level and hence achieve a similar speed-up factor. Conclusion: Our studies have demonstrated the feasibility and effectiveness of our auto-commissioning approach and new efficient source sampling strategy, implying the potential of our GPU-based MC dose engine goMC for routine clinical use.« less
A Case of Human Infection by Rickettsia slovaca in Greece.
Kostopoulou, Vasiliki; Chochlakis, Dimosthenis; Kanta, Chrysoula; Katsanou, Andromachi; Rossiou, Konstantina; Rammos, Aidonis; Papadopoulos, Spyridon-Filippos; Katsarou, Theodora; Tselentis, Yannis; Psaroulaki, Anna; Boukas, Chrysostomos
2016-07-22
Although tick-borne rickettsiosis is endemic in Greece, until recently, human samples arriving at the National Reference Centre under suspicion of rickettsial infection were routinely tested only for Rickettsia typhi and R. conorii. However, identification of additional rickettsia species in ticks prompted revision of the protocol in 2010. Until that year, all human samples received by the laboratory were tested for antibodies against R. conorii and R. typhi only. Now, tests for R. slovaca, R. felis, and R. mongolotimonae are all included in routine analysis. The current description of a human R. slovaca case is possible as a result of these changes in routine testing.
Kluge, Annette; Gronau, Norbert
2018-01-01
To cope with the already large, and ever increasing, amount of information stored in organizational memory, "forgetting," as an important human memory process, might be transferred to the organizational context. Especially in intentionally planned change processes (e.g., change management), forgetting is an important precondition to impede the recall of obsolete routines and adapt to new strategic objectives accompanied by new organizational routines. We first comprehensively review the literature on the need for organizational forgetting and particularly on accidental vs. intentional forgetting. We discuss the current state of the art of theory and empirical evidence on forgetting from cognitive psychology in order to infer mechanisms applicable to the organizational context. In this respect, we emphasize retrieval theories and the relevance of retrieval cues important for forgetting. Subsequently, we transfer the empirical evidence that the elimination of retrieval cues leads to faster forgetting to the forgetting of organizational routines, as routines are part of organizational memory. We then propose a classification of cues (context, sensory, business process-related cues) that are relevant in the forgetting of routines, and discuss a meta-cue called the "situational strength" cue, which is relevant if cues of an old and a new routine are present simultaneously. Based on the classification as business process-related cues (information, team, task, object cues), we propose mechanisms to accelerate forgetting by eliminating specific cues based on the empirical and theoretical state of the art. We conclude that in intentional organizational change processes, the elimination of cues to accelerate forgetting should be used in change management practices.
Kluge, Annette; Gronau, Norbert
2018-01-01
To cope with the already large, and ever increasing, amount of information stored in organizational memory, “forgetting,” as an important human memory process, might be transferred to the organizational context. Especially in intentionally planned change processes (e.g., change management), forgetting is an important precondition to impede the recall of obsolete routines and adapt to new strategic objectives accompanied by new organizational routines. We first comprehensively review the literature on the need for organizational forgetting and particularly on accidental vs. intentional forgetting. We discuss the current state of the art of theory and empirical evidence on forgetting from cognitive psychology in order to infer mechanisms applicable to the organizational context. In this respect, we emphasize retrieval theories and the relevance of retrieval cues important for forgetting. Subsequently, we transfer the empirical evidence that the elimination of retrieval cues leads to faster forgetting to the forgetting of organizational routines, as routines are part of organizational memory. We then propose a classification of cues (context, sensory, business process-related cues) that are relevant in the forgetting of routines, and discuss a meta-cue called the “situational strength” cue, which is relevant if cues of an old and a new routine are present simultaneously. Based on the classification as business process-related cues (information, team, task, object cues), we propose mechanisms to accelerate forgetting by eliminating specific cues based on the empirical and theoretical state of the art. We conclude that in intentional organizational change processes, the elimination of cues to accelerate forgetting should be used in change management practices. PMID:29449821
Rapid targeted somatic mutation analysis of solid tumors in routine clinical diagnostics.
Magliacane, Gilda; Grassini, Greta; Bartocci, Paola; Francaviglia, Ilaria; Dal Cin, Elena; Barbieri, Gianluca; Arrigoni, Gianluigi; Pecciarini, Lorenza; Doglioni, Claudio; Cangi, Maria Giulia
2015-10-13
Tumor genotyping is an essential step in routine clinical practice and pathology laboratories face a major challenge in being able to provide rapid, sensitive and updated molecular tests. We developed a novel mass spectrometry multiplexed genotyping platform named PentaPanel to concurrently assess single nucleotide polymorphisms in 56 hotspots of the 5 most clinically relevant cancer genes, KRAS, NRAS, BRAF, EGFR and PIK3CA for a total of 221 detectable mutations. To both evaluate and validate the PentaPanel performance, we investigated 1025 tumor specimens of 6 different cancer types (carcinomas of colon, lung, breast, pancreas, and biliary tract, and melanomas), systematically addressing sensitivity, specificity, and reproducibility of our platform. Sanger sequencing was also performed for all the study samples. Our data showed that PentaPanel is a high throughput and robust tool, allowing genotyping for targeted therapy selection of 10 patients in the same run, with a practical turnaround time of 2 working days. Importantly, it was successfully used to interrogate different DNAs isolated from routinely processed specimens (formalin-fixed paraffin embedded, frozen, and cytological samples), covering all the requirements of clinical tests. In conclusion, the PentaPanel platform can provide an immediate, accurate and cost effective multiplex approach for clinically relevant gene mutation analysis in many solid tumors and its utility across many diseases can be particularly relevant in multiple clinical trials, including the new basket trial approach, aiming to identify appropriate targeted drug combination strategies.
External evaluation of the Dimension Vista 1500® intelligent lab system.
Bruneel, Arnaud; Dehoux, Monique; Barnier, Anne; Boutten, Anne
2012-09-01
Dimension Vista® analyzer combines four technologies (photometry, nephelometry, V-LYTE® integrated multisensor potentiometry, and LOCI® chemiluminescence) into one high-throughput system. We assessed analytical performance of assays routinely performed in our emergency laboratory according to the VALTEC protocol, and practicability. Precision was good for most parameters. Analytical domain was large and suitable for undiluted analysis in most clinical settings encountered in our hospital. Data were comparable and correlated to our routine analyzers (Roche Modular DP®, Abbott AXSYM®, Siemens Dimension® RxL, and BN ProSpec®). Performance of nephelometric and LOCI modules was excellent. Functional sensitivity of high-sensitivity C-reactive protein and cardiac troponin I were 0.165 mg/l and 0.03 ng/ml, respectively (coefficient of variation; CV < 10%). The influence of interfering substances (i.e., hemoglobin, bilirubin, or lipids) was moderate, and Dimension Vista® specifically alerted for interference according to HIL (hemolysis, icterus, lipemia) indices. Good instrument performance and full functionality (no reagent or sample carryover in the conditions evaluated, effective sample-volume detection, and clot detection) were confirmed. Simulated routine testing demonstrated excellent practicability, throughput, ease of use of software and security. Performance and practicability of Dimension Vista® are highly suitable for both routine and emergency use. Since no volume detection and thus no warning is available on limited sample racks, pediatric samples require special caution to the Siemens protocol to be analyzed in secured conditions. Our experience in routine practice is also discussed, i.e., the impact of daily workload, "manual" steps resulting from dilutions and pediatric samples, maintenances, flex hydration on instrument's performance on throughput and turnaround time. © 2012 Wiley Periodicals, Inc.
ERIC Educational Resources Information Center
Fuligni, Allison Sidle; Howes, Carollee; Huang, Yiching; Hong, Sandra Soliday; Lara-Cinisomo, Sandraluz
2012-01-01
This paper examines activity settings and daily classroom routines experienced by 3- and 4-year-old low-income children in public center-based preschool programs, private center-based programs, and family child care homes. Two daily routine profiles were identified using a time-sampling coding procedure: a High Free-Choice pattern in which…
Harding-Esch, Emma M; Nori, Achyuta V; Hegazi, Aseel; Pond, Marcus J; Okolo, Olanike; Nardone, Anthony; Lowndes, Catherine M; Hay, Phillip; Sadiq, S Tariq
2017-09-01
To assess clinical service value of STI point-of-care test (POCT) use in a 'sample first' clinical pathway (patients providing samples on arrival at clinic, before clinician consultation). Specific outcomes were: patient acceptability; whether a rapid nucleic acid amplification test (NAAT) for Chlamydia trachomatis/Neisseria gonorrhoeae (CT/NG) could be used as a POCT in practice; feasibility of non-NAAT POCT implementation for Trichomonas vaginalis (TV) and bacterial vaginosis (BV); impact on patient diagnosis and treatment. Service evaluation in a south London sexual health clinic. Symptomatic female and male patients and sexual contacts of CT/NG-positive individuals provided samples for diagnostic testing on clinic arrival, prior to clinical consultation. Tests included routine culture and microscopy; CT/NG (GeneXpert) NAAT; non-NAAT POCTs for TV and BV. All 70 (35 males, 35 females) patients approached participated. The 'sample first' pathway was acceptable, with >90% reporting they were happy to give samples on arrival and receive results in the same visit. Non-NAAT POCT results were available for all patients prior to leaving clinic; rapid CT/NG results were available for only 21.4% (15/70; 5 males, 10 females) of patients prior to leaving clinic. Known negative CT/NG results led to two females avoiding presumptive treatment, and one male receiving treatment directed at possible Mycoplasma genitalium infection causing non-gonococcal urethritis. Non-NAAT POCTs detected more positives than routine microscopy (TV 3 vs 2; BV 24 vs 7), resulting in more patients receiving treatment. A 'sample first' clinical pathway to enable multiple POCT use was acceptable to patients and feasible in a busy sexual health clinic, but rapid CT/NG processing time was too long to enable POCT use. There is need for further development to improve test processing times to enable POC use of rapid NAATs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
DNA profiles from clothing fibers using direct PCR.
Blackie, Renée; Taylor, Duncan; Linacre, Adrian
2016-09-01
We report on the successful use of direct PCR amplification of single fibers from items of worn clothing. Items of clothing were worn throughout the course of a day, with the individual commencing regular activities. Single fibers were taken from the cuff of the clothing at regular intervals and amplified directly. The same areas were subjected to tape-lifting, and also amplified directly for comparison. The NGM™ kit that amplifies 15 STR loci plus amelogenin was used. A total of 35 single fiber samples were processed and analyzed from five items of clothing, with 81 % of samples returning a profile of 14 alleles or more. All tape-lift samples amplified directly produced DNA profiles of 15 alleles or more. The aim was to develop a simple, operational method that could be used routinely in forensic science casework and that has the potential to generate more complete profiles, which would not be detected using standard extraction methods on this type of sample. For ease of implementation, the process also adheres to standard methods with no increase in the cycle number.
School Success as a Process of Structuration
ERIC Educational Resources Information Center
Tubin, Dorit
2015-01-01
Purpose: The purpose of the present study is to explore the process, routines, and structuration at successful schools leading their students to high achievements. Method: The approach of building a theory from case study research together with process perspective and an organizational routines model were applied to analyzing seven successful…
Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal
2007-07-01
Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.
Alvarez, D.A.; Stackelberg, P.E.; Petty, J.D.; Huckins, J.N.; Furlong, E.T.; Zaugg, S.D.; Meyer, M.T.
2005-01-01
Four water samples collected using standard depth and width water-column sampling methodology were compared to an innovative passive, in situ, sampler (the polar organic chemical integrative sampler or POCIS) for the detection of 96 organic wastewater-related contaminants (OWCs) in a stream that receives agricultural, municipal, and industrial wastewaters. Thirty-two OWCs were identified in POCIS extracts whereas 9-24 were identified in individual water-column samples demonstrating the utility of POCIS for identifying contaminants whose occurrence are transient or whose concentrations are below routine analytical detection limits. Overall, 10 OWCs were identified exclusively in the POCIS extracts and only six solely identified in the water-column samples, however, repetitive water samples taken using the standard method during the POCIS deployment period required multiple trips to the sampling site and an increased number of samples to store, process, and analyze. Due to the greater number of OWCs detected in the POCIS extracts as compared to individual water-column samples, the ease of performing a single deployment as compared to collecting and processing multiple water samples, the greater mass of chemical residues sequestered, and the ability to detect chemicals which dissipate quickly, the passive sampling technique offers an efficient and effective alternative for detecting OWCs in our waterways for wastewater contaminants.
Study design requirements for RNA sequencing-based breast cancer diagnostics.
Mer, Arvind Singh; Klevebring, Daniel; Grönberg, Henrik; Rantalainen, Mattias
2016-02-01
Sequencing-based molecular characterization of tumors provides information required for individualized cancer treatment. There are well-defined molecular subtypes of breast cancer that provide improved prognostication compared to routine biomarkers. However, molecular subtyping is not yet implemented in routine breast cancer care. Clinical translation is dependent on subtype prediction models providing high sensitivity and specificity. In this study we evaluate sample size and RNA-sequencing read requirements for breast cancer subtyping to facilitate rational design of translational studies. We applied subsampling to ascertain the effect of training sample size and the number of RNA sequencing reads on classification accuracy of molecular subtype and routine biomarker prediction models (unsupervised and supervised). Subtype classification accuracy improved with increasing sample size up to N = 750 (accuracy = 0.93), although with a modest improvement beyond N = 350 (accuracy = 0.92). Prediction of routine biomarkers achieved accuracy of 0.94 (ER) and 0.92 (Her2) at N = 200. Subtype classification improved with RNA-sequencing library size up to 5 million reads. Development of molecular subtyping models for cancer diagnostics requires well-designed studies. Sample size and the number of RNA sequencing reads directly influence accuracy of molecular subtyping. Results in this study provide key information for rational design of translational studies aiming to bring sequencing-based diagnostics to the clinic.
Sturgeon, Catharine; Hill, Robert; Hortin, Glen L; Thompson, Douglas
2010-01-01
There is increasing pressure to provide cost-effective healthcare based on “best practice.” Consequently, new biomarkers are only likely to be introduced into routine clinical biochemistry departments if they are supported by a strong evidence base and if the results will improve patient management and outcome. This requires convincing evidence of the benefits of introducing the new test, ideally reflected in fewer hospital admissions, fewer additional investigations and/or fewer clinic visits. Carefully designed audit and cost-benefit studies in relevant patient groups must demonstrate that introducing the biomarker delivers an improved and more effective clinical pathway. From the laboratory perspective, pre-analytical requirements must be thoroughly investigated at an early stage. Good stability of the biomarker in relevant physiological matrices is essential to avoid the need for special processing. Absence of specific timing requirements for sampling and knowledge of the effect of medications that might be used to treat the patients in whom the biomarker will be measured is also highly desirable. Analytically, automation is essential in modern high-throughput clinical laboratories. Assays must therefore be robust, fulfilling standard requirements for linearity on dilution, precision and reproducibility, both within- and between-run. Provision of measurements by a limited number of specialized reference laboratories may be most appropriate, especially when a new biomarker is first introduced into routine practice. PMID:21137030
Visual body perception in anorexia nervosa.
Urgesi, Cosimo; Fornasari, Livia; Perini, Laura; Canalaz, Francesca; Cremaschi, Silvana; Faleschini, Laura; Balestrieri, Matteo; Fabbro, Franco; Aglioti, Salvatore Maria; Brambilla, Paolo
2012-05-01
Disturbance of body perception is a central aspect of anorexia nervosa (AN) and several neuroimaging studies have documented structural and functional alterations of occipito-temporal cortices involved in visual body processing. However, it is unclear whether these perceptual deficits involve more basic aspects of others' body perception. A consecutive sample of 15 adolescent patients with AN were compared with a group of 15 age- and gender-matched controls in delayed matching to sample tasks requiring the visual discrimination of the form or of the action of others' body. Patients showed better visual discrimination performance than controls in detail-based processing of body forms but not of body actions, which positively correlated with their increased tendency to convert a signal of punishment into a signal of reinforcement (higher persistence scores). The paradoxical advantage of patients with AN in detail-based body processing may be associated to their tendency to routinely explore body parts as a consequence of their obsessive worries about body appearance. Copyright © 2012 Wiley Periodicals, Inc.
Karumaa, Santra; Kärpänoja, Pauliina; Sarkkinen, Hannu
2012-03-01
We have evaluated the GenoType blood culture assay (Hain Lifescience, Nehren, Germany) for the identification of bacteria in 233 positive blood cultures and assessed its suitability in the workflow of a routine microbiology laboratory. In 68/233 (29.2%) samples, the culture result could not be confirmed by the GenoType assay due to a lack of primers in the test, multiple organisms in the sample, or inconsistency with respect to the identification by culture. Although the GenoType blood culture assay gives satisfactory results for bacteria for which primers are available, there are difficulties in applying the test in the routine microbiology laboratory.
A low cost Doppler system for vascular dialysis access surveillance.
Molina, P S C; Moraes, R; Baggio, J F R; Tognon, E A
2004-01-01
The National Kidney Foundation guidelines for vascular access recommend access surveillance to avoid morbidity among patients undergoing hemodialysis. Methods to detect access failure based on CW Doppler system are being proposed to implement surveillance programs at lower cost. This work describes a low cost Doppler system implemented in a PC notebook designed to carry out this task. A Doppler board samples the blood flow velocity and delivers demodulated quadrature Doppler signals. These signals are sampled by a notebook sound card. Software for Windows OS (running at the notebook) applies CFFT to consecutive 11.6 ms intervals of Doppler signals. The sonogram is presented on the screen in real time. The software also calculates the maximum and the intensity weighted mean frequency envelopes. Since similar systems employ DSP boards to process the Doppler signals, cost reduction was achieved. The Doppler board electronic circuits and routines to process the Doppler signals are presented.
Danese, Andrea; Shalev, Idan; Williams, Benjamin S.; Caspi, Avshalom
2015-01-01
Routine incorporation of blood-based biomarker measurements in population studies has been hampered by challenges in obtaining samples suitable for biomarker assessment outside of laboratory settings. Here, we assessed the suitability of venous blood left unprocessed for four, 24 or 48 hours post-collection at either room temperature or 4°C for quantification of two biomarkers, Interleukin-6 (IL-6) and C-Reactive Protein (CRP). Blood samples were collected in both K2EDTA tubes and a dedicated plasma-preservation tube, P100. Dried Blood Spot (DBS) samples from the same subjects were also collected in order to compare delayed-processing plasma performance against a popular alternative collection method. K2EDTA mean plasma concentrations of both IL-6 and CRP were not significantly different from concentrations in plasma processed immediately; this was observed for tubes stored up to 48 hours pre-processing at either temperature. Concentrations of IL-6 measured in P100 tubes showed significant time-dependent increases when stored at room temperature; otherwise, levels of IL-6 and CRP were similar to those processed immediately. Levels of CRP in DBS were correlated with plasma CRP levels, even when pre-processed blood was stored for up to 48 hours. These data indicate that plasma is suitable for IL-6 and CRP estimation under data-collection conditions that involve processing delays. PMID:26652682
Hanna, Lisa; May, Carl; Fairhurst, Karen
2012-06-01
New information and communication technologies such as email and text messaging have been shown to be useful in some aspects of primary care service delivery. Little is known about Scottish GPs' attitudes towards the adoption of these technologies as routine consultation tools. To explore GPs' perceptions of the potential place of new non-face-to-face consultation technologies in the routine delivery of primary care; to explore GPs' perceived barriers to the introduction of these technologies and to identify the processes by which GPs feel that new consultation technologies could be incorporated into routine primary care. Qualitative interview study: 20 in-depth semi-structured interviews carried out with maximum variation sample of GPs across Scotland. Whilst the face-to-face consultation was seen as central to much of the clinical and diagnostic work of primary care, many GPs were conditionally willing to consider using new technologies in the future, particularly to carry out administrative or less complex tasks and therefore maximize practice efficiency and patient convenience. Key considerations were access to appropriate training, IT support and medico-legal guidance. GPs are conditionally willing to use new consultation media if clinically appropriate and if medico-legal and technical support is available.
Stoeckel, D.M.; Stelzer, E.A.; Dick, L.K.
2009-01-01
Quantitative PCR (qPCR), applied to complex environmental samples such as water, wastewater, and feces, is susceptible to methodological and sample related biases. In this study, we evaluated two exogenous DNA spike-and-recovery controls as proxies for recovery efficiency of Bacteroidales 16S rDNA gene sequences (AllBac and qHF183) that are used for microbial source tracking (MST) in river water. Two controls-(1) the plant pathogen Pantoea stewartii, carrying the chromosomal target gene cpsD, and (2) Escherichia coli, carrying the plasmid-borne target gene DsRed2-were added to raw water samples immediately prior to concentration and DNA extraction for qPCR. When applied to samples processed in replicate, recovery of each control was positively correlated with the observed concentration of each MST marker. Adjustment of MST marker concentrations according to recovery efficiency reduced variability in replicate analyses when consistent processing and extraction methodologies were applied. Although the effects of this procedure on accuracy could not be tested due to uncertainties in control DNA concentrations, the observed reduction in variability should improve the strength of statistical comparisons. These findings suggest that either of the tested spike-and-recovery controls can be useful to measure efficiency of extraction and recovery in routine laboratory processing. ?? 2009 Elsevier Ltd.
Magnetic force microscopy with frequency-modulated capacitive tip-sample distance control
NASA Astrophysics Data System (ADS)
Zhao, X.; Schwenk, J.; Mandru, A. O.; Penedo, M.; Baćani, M.; Marioni, M. A.; Hug, H. J.
2018-01-01
In a step towards routinely achieving 10 nm spatial resolution with magnetic force microscopy, we have developed a robust method for active tip-sample distance control based on frequency modulation of the cantilever oscillation. It allows us to keep a well-defined tip-sample distance of the order of 10 nm within better than +/- 0.4 nm precision throughout the measurement even in the presence of energy dissipative processes, and is adequate for single-passage non-contact operation in vacuum. The cantilever is excited mechanically in a phase-locked loop to oscillate at constant amplitude on its first flexural resonance mode. This frequency is modulated by an electrostatic force gradient generated by tip-sample bias oscillating from a few hundred Hz up to a few kHz. The sum of the side bands’ amplitudes is a proxy for the tip-sample distance and can be used for tip-sample distance control. This method can also be extended to other scanning probe microscopy techniques.
Hajeb, Parvaneh; Herrmann, Susan S; Poulsen, Mette E
2017-07-19
The guidance document SANTE 11945/2015 recommends that cereal samples be milled to a particle size preferably smaller than 1.0 mm and that extensive heating of the samples should be avoided. The aim of the present study was therefore to investigate the differences in milling procedures, obtained particle size distributions, and the resulting pesticide residue recovery when cereal samples were milled at the European Union National Reference Laboratories (NRLs) with their routine milling procedures. A total of 23 NRLs participated in the study. The oat and rye samples milled by each NRL were sent to the European Union Reference Laboratory on Cereals and Feedingstuff (EURL) for the determination of the particle size distribution and pesticide residue recovery. The results showed that the NRLs used several different brands and types of mills. Large variations in the particle size distributions and pesticide extraction efficiencies were observed even between samples milled by the same type of mill.
Casals, I; Reixach, M; Amat, J; Fuentes, M; Serra-Majem, L
1996-10-25
An HPLC isocratic method with pre-column derivatization and UV detection for the quantification of cyclamate and cyclohexylamine in urine samples is described. The method requires very little sample preparation. Free cyclohexylamine is analysed in a first run and subsequently cyclamate is analysed as cyclohexylamine, after the simple process of oxidation of the sample by means of hydrogen peroxide. Cycloheptylamine is used as internal standard. Trinitrobenzenesulfonic acid (TNBS) appears to be a good reagent for the pre-column derivatization. The time per run is 15 min; the coefficients of variation of the assays range from 1.1 to 5.5%; the limits of detection are 0.09 and 0.11 ppm for cyclohexylamine and cyclamate anion, respectively. The system described has always performed efficiently, with a high degree of stability, in daily routine work.
Single molecule targeted sequencing for cancer gene mutation detection.
Gao, Yan; Deng, Liwei; Yan, Qin; Gao, Yongqian; Wu, Zengding; Cai, Jinsen; Ji, Daorui; Li, Gailing; Wu, Ping; Jin, Huan; Zhao, Luyang; Liu, Song; Ge, Liangjin; Deem, Michael W; He, Jiankui
2016-05-19
With the rapid decline in cost of sequencing, it is now affordable to examine multiple genes in a single disease-targeted clinical test using next generation sequencing. Current targeted sequencing methods require a separate step of targeted capture enrichment during sample preparation before sequencing. Although there are fast sample preparation methods available in market, the library preparation process is still relatively complicated for physicians to use routinely. Here, we introduced an amplification-free Single Molecule Targeted Sequencing (SMTS) technology, which combined targeted capture and sequencing in one step. We demonstrated that this technology can detect low-frequency mutations using artificially synthesized DNA sample. SMTS has several potential advantages, including simple sample preparation thus no biases and errors are introduced by PCR reaction. SMTS has the potential to be an easy and quick sequencing technology for clinical diagnosis such as cancer gene mutation detection, infectious disease detection, inherited condition screening and noninvasive prenatal diagnosis.
Multiprocessor graphics computation and display using transputers
NASA Technical Reports Server (NTRS)
Ellis, Graham K.
1988-01-01
A package of two-dimensional graphics routines was developed to run on a transputer-based parallel processing system. These routines were designed to enable applications programmers to easily generate and display results from the transputer network in a graphic format. The graphics procedures were designed for the lowest possible network communication overhead for increased performance. The routines were designed for ease of use and to present an intuitive approach to generating graphics on the transputer parallel processing system.
Lee, Lobin A; Arvai, Kevin J; Jones, Dan
2015-07-01
As DNA sequencing of multigene panels becomes routine for cancer samples in the clinical laboratory, an efficient process for classifying variants has become more critical. Determining which germline variants are significant for cancer disposition and which somatic mutations are integral to cancer development or therapy response remains difficult, even for well-studied genes such as BRCA1 and TP53. We compare and contrast the general principles and lines of evidence commonly used to distinguish the significance of cancer-associated germline and somatic genetic variants. The factors important in each step of the analysis pipeline are reviewed, as are some of the publicly available annotation tools. Given the range of indications and uses of cancer sequencing assays, including diagnosis, staging, prognostication, theranostics, and residual disease detection, the need for flexible methods for scoring of variants is discussed. The usefulness of protein prediction tools and multimodal risk-based or Bayesian approaches are highlighted. Using TET2 variants encountered in hematologic neoplasms, several examples of this multifactorial approach to classifying sequence variants of unknown significance are presented. Although there are still significant gaps in the publicly available data for many cancer genes that limit the broad application of explicit algorithms for variant scoring, the elements of a more rigorous model are outlined. Copyright © 2015 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
Sutton, S; Saidi, G; Bickler, G; Hunter, J
1995-01-01
OBJECTIVE--To investigate whether mammography raises anxiety in routinely screened women who receive a negative result. DESIGN--Prospective design in which women completed questionnaires at three key points in the breast screening process: at baseline (before being sent their invitation for breast screening), at the screening clinic immediately before or after screening, and at follow up, about nine months after baseline. Information was obtained from non-attenders as well as from attenders. SETTING--Bromley District Health Authority, served by the South East London Breast Screening Service. PARTICIPANTS--Two overlapping samples were used. Sample A comprised 1500 women aged 50-64 who were due to be called for first round screening at a mobile screening unit. Altogether 1021 (68%) returned a usable questionnaire and 795 of these (78%) also provided adequate information at nine month follow up: there were 695 attenders (including 24 women who received false positive results) and 100 non-attenders. Sample B consisted of 868 women who attended the screening unit in a three month period, 732 (84%) of whom provided adequate data. A total of 306 attenders (including 10 who received false positive results) occurred in both samples and provided adequate information on all occasions. The main analyses were based on these 306 women plus the 100 non-attenders. The analysis of retrospective anxiety took advantage of the larger sample size of 695 attenders. MAIN RESULTS--On average, the women were not unduly anxious at any of the three points in the screening process. Among attenders, there was no difference between anxiety levels immediately before and immediately after screening. Anxiety was lowest at the clinic and highest at baseline but the changes were very small in absolute terms. Anxiety did not predict attendance: there were no differences in anxiety levels between attenders and non-attenders at baseline. As expected, women who received false positive results recalled feeling extremely anxious after they had received the referral letter but their retrospective anxiety was also higher than in the negative screenees at earlier stages in the breast screening process. They also reported having experienced more pain and discomfort during the x ray. CONCLUSIONS--Anxiety does not seem to be an important problem in routinely screened women who receive a negative result. This finding is very reassuring in relation to a major criticism of breast screening programmes. Thus, apart from maintaining current procedures such as keeping waiting times to a minimum, there seems to be no need to introduce special anxiety reducing interventions into the national programme. On the other hand, the findings for women who received false positive results suggest that there are aspects of the experience of being recalled for assessment after an abnormal mammogram that warrant further attention. The relationship between contemporaneous and retrospective anxiety should also be studied. PMID:7650466
Review of Pre-Analytical Errors in Oral Glucose Tolerance Testing in a Tertiary Care Hospital.
Nanda, Rachita; Patel, Suprava; Sahoo, Sibashish; Mohapatra, Eli
2018-03-13
The pre-pre-analytical and pre-analytical phases form a major chunk of the errors in a laboratory. The process has taken into consideration a very common procedure which is the oral glucose tolerance test to identify the pre-pre-analytical errors. Quality indicators provide evidence of quality, support accountability and help in the decision making of laboratory personnel. The aim of this research is to evaluate pre-analytical performance of the oral glucose tolerance test procedure. An observational study that was conducted overa period of three months, in the phlebotomy and accessioning unit of our laboratory using questionnaire that examined the pre-pre-analytical errors through a scoring system. The pre-analytical phase was analyzed for each sample collected as per seven quality indicators. About 25% of the population gave wrong answer with regard to the question that tested the knowledge of patient preparation. The appropriateness of test result QI-1 had the most error. Although QI-5 for sample collection had a low error rate, it is a very important indicator as any wrongly collected sample can alter the test result. Evaluating the pre-analytical and pre-pre-analytical phase is essential and must be conducted routinely on a yearly basis to identify errors and take corrective action and to facilitate their gradual introduction into routine practice.
Miranda, A; Saldaña, A; González, K; Paz, H; Santamaría, G; Samudio, F; Calzada, J E
2012-09-01
Cutaneous leishmaniasis (CL) is a major vectorborne disease in Panama. In this study, the diagnostic performance and usefulness of two DNA extraction procedures from skin scraping samples collected on FTA filter paper for subsequent PCR diagnosis of CL was evaluated. A positive CL laboratory diagnosis was based on a positive parasitological test (Giemsa-stained smears or in vitro culture) and/or positive PCR test performed from skin scrapings collected in TE buffer (PCR-TE). Of 100 patients with skin lesions suggestive of CL, 82 (82%) were confirmed as CL positive. The sensitivity was calculated for each of the PCR approaches from samples collected on filter paper. The highest sensitivity was achieved by PCR-FTA processed by Chelex 100 (PCR-Chelex) (0.94). PCR-FTA extracted using the FTA purification reagent presented a lower sensitivity (0.60). Good concordance between routine PCR-TE and PCR-Chelex was observed (percent agreement=0.88, κ index=0.65). In conclusion, use of FTA filter paper for skin scraping collection combined with PCR is a reliable and convenient method for CL diagnosis in Panama, with comparable performance to the routine PCR method and with improved sensitivity compared with those of conventional parasitological methods. Copyright © 2012 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.
Proposed Conceptual Requirements for the CTBT Knowledge Base,
1995-08-14
knowledge available to automated processing routines and human analysts are significant, and solving these problems is an essential step in ensuring...knowledge storage in a CTBT system. In addition to providing regional knowledge to automated processing routines, the knowledge base will also address
Microplates in liquid chromatography--new solution in clinical research? A review.
Krcmova, Lenka; Solichova, Dagmar; Solich, Petr
2013-10-15
Microplates are routinely used in Radio- or Immuno-assays. Recently, microplates have found use not only in analytical but also in the pre-analytical phase in bioanalyses (sample storage, sample preparation). New connection of this technology to liquid chromatography could be economical, fast and simple solution for many routine laboratories handling large sequences of biological samples. This review summarises the application of microplates in bioanalytical laboratories. Different types of sorbents, materials and shapes of microplates are discussed, and the main advantages and disadvantages of microplates used in clinical research are presented. Copyright © 2013 Elsevier B.V. All rights reserved.
Pollington, Anthony D.; Kinman, William S.; Hanson, Susan K.; ...
2015-09-04
Modern mass spectrometry and separation techniques have made measurement of major uranium isotope ratios a routine task; however accurate and precise measurement of the minor uranium isotopes remains a challenge as sample size decreases. One particular challenge is the presence of isobaric interferences and their impact on the accuracy of minor isotope 234U and 236U measurements. Furthermore, we present techniques used for routine U isotopic analysis of environmental nuclear safeguards samples and evaluate polyatomic interferences that negatively impact accuracy as well as methods to mitigate their impacts.
Kukreti, B M; Sharma, G K
2012-05-01
Accurate and speedy estimations of ppm range uranium and thorium in the geological and rock samples are most useful towards ongoing uranium investigations and identification of favorable radioactive zones in the exploration field areas. In this study with the existing 5 in. × 4 in. NaI(Tl) detector setup, prevailing background and time constraints, an enhanced geometrical setup has been worked out to improve the minimum detection limits for primordial radioelements K(40), U(238) and Th(232). This geometrical setup has been integrated with the newly introduced, digital signal processing based MCA system for the routine spectrometric analysis of low concentration rock samples. Stability performance, during the long counting hours, for digital signal processing MCA system and its predecessor NIM bin based MCA system has been monitored, using the concept of statistical process control. Monitored results, over a time span of few months, have been quantified in terms of spectrometer's parameters such as Compton striping constants and Channel sensitivities, used for evaluating primordial radio element concentrations (K(40), U(238) and Th(232)) in geological samples. Results indicate stable dMCA performance, with a tendency of higher relative variance, about mean, particularly for Compton stripping constants. Copyright © 2012 Elsevier Ltd. All rights reserved.
Trück, Johannes; Mitchell, Ruth; Thompson, Amber J; Morales-Aza, Begonia; Clutterbuck, Elizabeth A; Kelly, Dominic F; Finn, Adam; Pollard, Andrew J
2014-01-01
The ELISpot assay is used in vaccine studies for the quantification of antigen-specific memory B cells (B(MEM)), and can be performed using cryopreserved samples. The effects of cryopreservation on B(MEM) detection and the consistency of cultured ELISpot assays when performed by different operators or laboratories are unknown. In this study, blood was taken from healthy volunteers, and a cultured ELISpot assay was used to count B(MEM) specific for 2 routine vaccine antigens (diphtheria and tetanus toxoid). Results were assessed for intra- and inter-operator variation, and the effects of cryopreservation. Cryopreserved samples were shipped to a second laboratory in order to assess inter-laboratory variation. B(MEM) frequencies were very strongly correlated when comparing fresh and frozen samples processed by the same operator, and were also very strongly correlated when comparing 2 operators in the same laboratory. Results were slightly less consistent when samples were processed in different laboratories but correlation between the 2 measurements was still very strong. Although cell viability was reduced in some cryopreserved samples due to higher temperatures during transportation, B(MEM) could still be quantified. These results demonstrate the reproducibility of the ELISpot assay across operators and laboratories, and support the use of cryopreserved samples in future B(MEM) studies.
NASA Astrophysics Data System (ADS)
Knuth, F.; Crone, T. J.; Marburg, A.
2017-12-01
The Ocean Observatories Initiative's (OOI) Cabled Array is delivering real-time high-definition video data from an HD video camera (CAMHD), installed at the Mushroom hydrothermal vent in the ASHES hydrothermal vent field within the caldera of Axial Seamount, an active submarine volcano located approximately 450 kilometers off the coast of Washington at a depth of 1,542 m. Every three hours the camera pans, zooms and focuses in on nine distinct scenes of scientific interest across the vent, producing 14-minute-long videos during each run. This standardized video sampling routine enables scientists to programmatically analyze the content of the video using automated image analysis techniques. Each scene-specific time series dataset can service a wide range of scientific investigations, including the estimation of bacterial flux into the system by quantifying chemosynthetic bacterial clusters (floc) present in the water column, relating periodicity in hydrothermal vent fluid flow to earth tides, measuring vent chimney growth in response to changing hydrothermal fluid flow rates, or mapping the patterns of fauna colonization, distribution and composition across the vent over time. We are currently investigating the seventh scene in the sampling routine, focused on the bacterial mat covering the seafloor at the base of the vent. We quantify the change in bacterial mat coverage over time using image analysis techniques, and examine the relationship between mat coverage, fluid flow processes, episodic chimney collapse events, and other processes observed by Cabled Array instrumentation. This analysis is being conducted using cloud-enabled computer vision processing techniques, programmatic image analysis, and time-lapse video data collected over the course of the first CAMHD deployment, from November 2015 to July 2016.
Performance of Copan WASP for Routine Urine Microbiology
Quiblier, Chantal; Jetter, Marion; Rominski, Mark; Mouttet, Forouhar; Böttger, Erik C.; Keller, Peter M.
2015-01-01
This study compared a manual workup of urine clinical samples with fully automated WASPLab processing. As a first step, two different inocula (1 and 10 μl) and different streaking patterns were compared using WASP and InoqulA BT instrumentation. Significantly more single colonies were produced with the10-μl inoculum than with the 1-μl inoculum, and automated streaking yielded significantly more single colonies than manual streaking on whole plates (P < 0.001). In a second step, 379 clinical urine samples were evaluated using WASP and the manual workup. Average numbers of detected morphologies, recovered species, and CFUs per milliliter of all 379 urine samples showed excellent agreement between WASPLab and the manual workup. The percentage of urine samples clinically categorized as positive or negative did not differ between the automated and manual workflow, but within the positive samples, automated processing by WASPLab resulted in the detection of more potential pathogens. In summary, the present study demonstrates that (i) the streaking pattern, i.e., primarily the number of zigzags/length of streaking lines, is critical for optimizing the number of single colonies yielded from primary cultures of urine samples; (ii) automated streaking by the WASP instrument is superior to manual streaking regarding the number of single colonies yielded (for 32.2% of the samples); and (iii) automated streaking leads to higher numbers of detected morphologies (for 47.5% of the samples), species (for 17.4% of the samples), and pathogens (for 3.4% of the samples). The results of this study point to an improved quality of microbiological analyses and laboratory reports when using automated sample processing by WASP and WASPLab. PMID:26677255
Following the drill: the search for a dentist.
Motes, W H; Huhmann, B A; Hill, C J
1995-01-01
The authors identify strategically useful distinctions between the activities of potential patients in search of specialized vs. routine dental services. Survey findings question the advisability of assuming (1) that what occurs in the search process for routine dental care will automatically be mirrored in the process for more specialized services and (2) that potential patients use the same specific sources of information--both between (e.g., physicians vs. dentists) and within (e.g., specialized dental care vs. routine dental care) existing health care typologies.
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2011 CFR
2011-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.
Code of Federal Regulations, 2010 CFR
2010-07-01
... repeat sample or E. coli-positive repeat sample, or any total coliform-positive repeat sample following a fecal coliform-positive or E. coli-positive routine sample constitutes a violation of the MCL for total...
NASA Astrophysics Data System (ADS)
Liu, Yongliang; Chen, Yud-Ren; Nou, Xiangwu; Chao, Kaunglin
2007-09-01
Rapid and routine identification of foodborne bacteria are considerably important, because of bio- / agro- terrorism threats, public health concerns, and economic loss. Conventional, PCR, and immunoassay methods for the detection of bacteria are generally time-consuming, chemical reagent necessary and multi-step procedures. Fast microbial detection requires minimal sample preparation, permits the routine analysis of large numbers of samples with negligible reagent costs, and is easy to operate. Therefore, we have developed silver colloidal nanoparticle based surface-enhanced Raman scattering (SERS) spectroscopy as a potential tool for the rapid and routine detection of E. coli and L. monocytogenes. This study presents the further results of our examination on S. typhimonium, one of the most commonly outbreak bacteria, for the characteristic bands and subsequent identification.
Perfluoroalkyl substances are globally distributed in both urban and remote settings, and routinely are detected in wildlife, humans, and the environment. One of the most prominent and routinely detected perfluoroalkyl substances is perfluorooctanoic acid (PFOA), which has been s...
ADMAP (automatic data manipulation program)
NASA Technical Reports Server (NTRS)
Mann, F. I.
1971-01-01
Instructions are presented on the use of ADMAP, (automatic data manipulation program) an aerospace data manipulation computer program. The program was developed to aid in processing, reducing, plotting, and publishing electric propulsion trajectory data generated by the low thrust optimization program, HILTOP. The program has the option of generating SC4020 electric plots, and therefore requires the SC4020 routines to be available at excution time (even if not used). Several general routines are present, including a cubic spline interpolation routine, electric plotter dash line drawing routine, and single parameter and double parameter sorting routines. Many routines are tailored for the manipulation and plotting of electric propulsion data, including an automatic scale selection routine, an automatic curve labelling routine, and an automatic graph titling routine. Data are accepted from either punched cards or magnetic tape.
Validating Analytical Protocols to Determine Selected Pesticides and PCBs Using Routine Samples.
Pindado Jiménez, Oscar; García Alonso, Susana; Pérez Pastor, Rosa María
2017-01-01
This study aims at providing recommendations concerning the validation of analytical protocols by using routine samples. It is intended to provide a case-study on how to validate the analytical methods in different environmental matrices. In order to analyze the selected compounds (pesticides and polychlorinated biphenyls) in two different environmental matrices, the current work has performed and validated two analytical procedures by GC-MS. A description is given of the validation of the two protocols by the analysis of more than 30 samples of water and sediments collected along nine months. The present work also scopes the uncertainty associated with both analytical protocols. In detail, uncertainty of water sample was performed through a conventional approach. However, for the sediments matrices, the estimation of proportional/constant bias is also included due to its inhomogeneity. Results for the sediment matrix are reliable, showing a range 25-35% of analytical variability associated with intermediate conditions. The analytical methodology for the water matrix determines the selected compounds with acceptable recoveries and the combined uncertainty ranges between 20 and 30%. Analyzing routine samples is rarely applied to assess trueness of novel analytical methods and up to now this methodology was not focused on organochlorine compounds in environmental matrices.
NASA Technical Reports Server (NTRS)
Holdeman, J. D.; Lezberg, E. A.
1976-01-01
Atmospheric trace constituents in the upper troposphere and lower stratosphere are now being measured as part of the NASA Global Atmospheric Sampling Program (GASP), using fully automated air sampling systems on board commercial 747 aircraft in routine airline service. Measurements of atmospheric ozone and related meteorological and flight information obtained during several GASP flights in March 1975 are now available from the National Climatic Center, Asheville, North Carolina. In addition to the data from the aircraft, tropopause pressure data obtained from the National Meteorological Center (NMC) archives for the dates of the flights are included. This report is the first of a series of reports which describes the data currently available from GASP, including flight routes and dates, instrumentation, the data processing procedure used, and data tape specifications.
Olshansky, Ellen; Zender, Robynn; Kain, Zeev N; Rosales, Alvina; Guadarrama, Josue; Fortier, Michelle A
2015-07-01
The purpose was to understand the processes Hispanic parents undergo in managing postoperative care of children after routine surgical procedures. Sixty parents of children undergoing outpatient surgery were interviewed. Data were analyzed using grounded theory methodology. Parents experienced five subprocesses that comprised the overall process of caring for a child after routine surgery: (a) becoming informed; (b) preparing; (c) seeking reassurance; (d) communicating with one's child; and (e) making pain management decisions. Addressing cultural factors related to pain management in underserved families may instill greater confidence in managing pain. © 2015, Wiley Periodicals, Inc.
Sahmel, J; Devlin, K; Burns, A; Ferracini, T; Ground, M; Paustenbach, D
2013-01-01
Benzene, a known carcinogen, can be generated as a by-product during the use of petroleum-based raw materials in chemical manufacturing. The aim of this study was to analyze a large data set of benzene air concentration measurements collected over nearly 40 years during routine employee exposure monitoring at a petrochemical manufacturing facility. The facility used ethane, propane, and natural gas as raw materials in the production of common commercial materials such as polyethylene, polypropylene, waxes, adhesives, alcohols, and aldehydes. In total, 3607 benzene air samples were collected at the facility from 1962 to 1999. Of these, in total 2359 long-term (>1 h) personal exposure samples for benzene were collected during routine operations at the facility between 1974 and 1999. These samples were analyzed by division, department, and job title to establish employee benzene exposures in different areas of the facility over time. Sampling data were also analyzed by key events over time, including changes in the occupational exposure limits (OELs) for benzene and key equipment process changes at the facility. Although mean benzene concentrations varied according to operation, in nearly all cases measured benzene quantities were below the OEL in place at the time for benzene (10 ppm for 1974-1986 and 1 ppm for 1987-1999). Decreases in mean benzene air concentrations were also found when data were evaluated according to 7- to 10-yr periods following key equipment process changes. Further, an evaluation of mortality rates for a retrospective employee cohort (n = 3938) demonstrated that the average personal benzene exposures at this facility (0.89 ppm for the period 1974-1986 and 0.125 ppm for the period 1987-1999) did not result in increased standardized mortality ratio (SMRs) for diseases or malignancies of the lymphatic system. The robust nature of this data set provides comprehensive exposure information that may be useful for assessing human benzene exposures at similar facilities. The data also provide a basis for comparable measured exposure levels and the potential for adverse health effects. These data may also prove beneficial for comparing relative exposure potential for production versus nonproduction operations and the relationship between area and personal breathing zone samples.
Process control and dosimetry in a multipurpose irradiation facility
NASA Astrophysics Data System (ADS)
Cabalfin, E. G.; Lanuza, L. G.; Solomon, H. M.
1999-08-01
Availability of the multipurpose irradiation facility at the Philippine Nuclear Research Institute has encouraged several local industries to use gamma radiation for sterilization or decontamination of various products. Prior to routine processing, dose distribution studies are undertaken for each product and product geometry. During routine irradiation, dosimeters are placed at the minimum and maximum dose positions of a process load.
Enders, Martin; Hunjet, Andrea; Gleich, Michael; Imdahl, Roland; Mühlbacher, Annelies; Schennach, Harald; Chaiwong, Kriangsak; Sakuldamrongpanich, Tasanee; Turhan, Ajda; Sertöz, Rüchan; Wolf, Eva; Mayer, Wolfgang; Tao, Chuanmin; Wang, Lan Lan; Semprini, Simona
2014-01-01
Syphilis is a health problem of increasing incidence in recent years that may have severe complications if not diagnosed and treated at an early stage. There are many diagnostic tests available for syphilis, but there is no gold standard, and diagnosis therefore usually relies upon a combination of tests. In this multicenter study, we evaluated the treponemal Elecsys syphilis assay for use in the diagnosis of syphilis in routine samples, i.e., when syphilis is suspected or during antenatal or blood donation screening. The sensitivity and specificity of the Elecsys syphilis assay were compared head to head with those of other treponemal assays used in routine clinical practice and were assessed in potentially cross-reactive samples from patients with Epstein-Barr virus, HIV, and Lyme disease. In a total of 8,063 syphilis-negative samples collected from routine diagnostic requests and blood donations, the Elecsys syphilis assay had a specificity of 99.88%. In 928 samples previously identified as syphilis positive, the sensitivity was 99.57 to 100% (the result is presented as a range depending on whether four initially indeterminate samples are included in the assessment). The specificity of the Elecsys syphilis assay in patients with other infections was 100%; no false-positive samples were identified. PMID:25355799
Post-analytical stability of 23 common chemistry and immunochemistry analytes in incurred samples.
Nielsen, Betina Klint; Frederiksen, Tina; Friis-Hansen, Lennart; Larsen, Pia Bükmann
2017-12-01
Storage of blood samples after centrifugation, decapping and initial sampling allows ordering of additional blood tests. The pre-analytic stability of biochemistry and immunochemistry analytes has been studied in detail, but little is known about the post-analytical stability in incurred samples. We examined the stability of 23 routine analytes on the Dimension Vista® (Siemens Healthineers, Denmark): 42-60 routine samples in lithium-heparin gel tubes (Vacutainer, BD, USA) were centrifuged at 3000×g for 10min. Immediately after centrifugation, initial concentration of analytes were measured in duplicate (t=0). The tubes were stored decapped at room temperature and re-analyzed after 2, 4, 6, 8 and 10h in singletons. The concentration from reanalysis were normalized to initial concentration (t=0). Internal acceptance criteria for bias and total error were used to determine stability of each analyte. Additionally, evaporation from the decapped blood collection tubes and the residual platelet count in the plasma after centrifugation were quantified. We report a post-analytical stability of most routine analytes of ≥8h and do therefore - with few exceptions - suggest a standard 8hour-time limit for reordering and reanalysis of analytes in incurred samples. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Gut Microbiota Patterns Associated with Colonization of Different Clostridium difficile Ribotypes
Skraban, Jure; Dzeroski, Saso; Zenko, Bernard; Mongus, Domen; Gangl, Simon; Rupnik, Maja
2013-01-01
C. difficile infection is associated with disturbed gut microbiota and changes in relative frequencies and abundance of individual bacterial taxons have been described. In this study we have analysed bacterial, fungal and archaeal microbiota by denaturing high pressure liquid chromatography (DHPLC) and with machine learning methods in 208 faecal samples from healthy volunteers and in routine samples with requested C. difficile testing. The latter were further divided according to stool consistency, C. difficile presence or absence and C. difficile ribotype (027 or non-027). Lower microbiota diversity was a common trait of all routine samples and not necessarily connected only to C. difficile colonisation. Differences between the healthy donors and C. difficile positive routine samples were detected in bacterial, fungal and archaeal components. Bifidobacterium longum was the single most important species associated with C. difficile negative samples. However, by machine learning approaches we have identified patterns of microbiota composition predictive for C. difficile colonization. Those patterns also differed between samples with C. difficile ribotype 027 and other C. difficile ribotypes. The results indicate that not only the presence of a single species/group is important but that certain combinations of gut microbes are associated with C. difficile carriage and that some ribotypes (027) might be associated with more disturbed microbiota than the others. PMID:23469128
Collins, S; Stevenson, D; Walker, J; Bennett, A
2017-06-01
To evaluate the usefulness of Legionella qPCR alongside traditional culture for enumeration of Legionella from water samples as part of both routine and public health investigation testing. Routine water samples (n = 2002) and samples from public health investigations (n = 215) were analysed by culture and qPCR for Legionella spp., Legionella pneumophila and L. pneumophila sg-1. A negative qPCR result was highly predictive of a negative culture result for all water systems (negative predictive values, NPV from 97·4 to 100%). Positive predictive values (PPV) were lower (0-50%). Results for qPCR were generally larger than culture with average log 10 differences of 1·1 for Legionella spp. and 1·2 for L. pneumophila. Alert and action levels of 1000 and 10 000 GU per litre, respectively, are proposed for Legionella qPCR for hot and cold water systems (HCWS). The use of qPCR significantly reduced the time to results for public health investigations by rapidly identifying potential sources and ruling out others, thus enabling a more rapid and efficient response. The high NPV of qPCR supports its use to rapidly screen out negative samples without culture. Alert and action levels for Legionella qPCR for HCWS are proposed. Quantitative PCR will be a valuable tool for both routine and public health testing. This study generated comparative data of >2000 water samples by qPCR and culture. Action and alert levels have been recommended that could enable duty holders to interpret qPCR results to facilitate timely Legionella control and public health protection. © 2017 Crown copyright. Journal of Applied Microbiology © 2017 The Society for Applied Microbiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, T.; Pareizs, J.; Coleman, C.
For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt ormore » SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.« less
Forer, Yaara; Block, Colin; Frenkel, Shahar
2017-09-01
The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p < 0.0001). There was no statistically significant difference between log 10 reductions for CHG and PVP-I (p = 0.97). This study provides evidence that an alcohol rub protocol is more effective in reducing bacterial counts on hands than routine surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a preoperative hand disinfection method.
Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J
2016-06-01
The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
When Routines Are Not so Routine: Exploring Coordination Work in Hospitals
ERIC Educational Resources Information Center
Haque, Saira Naim
2010-01-01
Many work processes take place through routines, or recurrent patterns of action. These activities involve individuals from several occupations working across spatial, temporal, and organizational boundaries. Crossing these professional, temporal and spatial boundaries has unique challenges which can lead to coordination failures. In these…
40 CFR 141.806 - Reporting requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... development of the coliform sampling plan, the operations and maintenance plan, and the disinfection and... operations and maintenance plan required by § 141.804 and report the frequency for routine disinfection and... frequency for routine disinfection and flushing within the first calendar quarter of initial operation of...
40 CFR 141.806 - Reporting requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... development of the coliform sampling plan, the operations and maintenance plan, and the disinfection and... operations and maintenance plan required by § 141.804 and report the frequency for routine disinfection and... frequency for routine disinfection and flushing within the first calendar quarter of initial operation of...
7 CFR 372.5 - Classification of actions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... in paragraph (c) of this section. (2) Planning, design, construction, or acquisition of new... categorically excluded, as provided in paragraph (c) of this section. (5) Research or testing that: (i) Will be...) Routine measures. (i) Routine measures, such as identifications, inspections, surveys, sampling that does...
7 CFR 372.5 - Classification of actions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... in paragraph (c) of this section. (2) Planning, design, construction, or acquisition of new... categorically excluded, as provided in paragraph (c) of this section. (5) Research or testing that: (i) Will be...) Routine measures. (i) Routine measures, such as identifications, inspections, surveys, sampling that does...
7 CFR 372.5 - Classification of actions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... in paragraph (c) of this section. (2) Planning, design, construction, or acquisition of new... categorically excluded, as provided in paragraph (c) of this section. (5) Research or testing that: (i) Will be...) Routine measures. (i) Routine measures, such as identifications, inspections, surveys, sampling that does...
7 CFR 372.5 - Classification of actions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... in paragraph (c) of this section. (2) Planning, design, construction, or acquisition of new... categorically excluded, as provided in paragraph (c) of this section. (5) Research or testing that: (i) Will be...) Routine measures. (i) Routine measures, such as identifications, inspections, surveys, sampling that does...
7 CFR 372.5 - Classification of actions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... in paragraph (c) of this section. (2) Planning, design, construction, or acquisition of new... categorically excluded, as provided in paragraph (c) of this section. (5) Research or testing that: (i) Will be...) Routine measures. (i) Routine measures, such as identifications, inspections, surveys, sampling that does...
SIGPROC: Pulsar Signal Processing Programs
NASA Astrophysics Data System (ADS)
Lorimer, D. R.
2011-07-01
SIGPROC is a package designed to standardize the initial analysis of the many types of fast-sampled pulsar data. Currently recognized machines are the Wide Band Arecibo Pulsar Processor (WAPP), the Penn State Pulsar Machine (PSPM), the Arecibo Observatory Fourier Transform Machine (AOFTM), the Berkeley Pulsar Processors (BPP), the Parkes/Jodrell 1-bit filterbanks (SCAMP) and the filterbank at the Ooty radio telescope (OOTY). The SIGPROC tools should help users look at their data quickly, without the need to write (yet) another routine to read data or worry about big/little endian compatibility (byte swapping is handled automatically).
Parkhurst, David L.
1987-01-01
Chemical analyses are presented for 169 water samples from Tar Creek drainage and the Picher lead-zinc mining area of northeast Oklahoma and southeast Kansas. Water samples were taken from November 1983 through February 1986 from the abandoned mines, from points of mine-water discharge, and from surface-water locations upstream and downstream from mine discharge area. The pH, temperature, alkalinity, dissolved oxygen, and specific conductance were measured in the field. Laboratory analyses routinely included the major ions plus aluminum, cadmium, copper, iron, lead, manganese, nickel, and zinc. Non-routine analyses of dissolved gases and tritium are presented. Stable carbon-isotope ratios for 11 mine-water samples and three carbonate-rock samples are reported. Miscellaneous stream-discharge measurements made at the time of sampling or taken from gaging-station records are included in the report.
Zhang, Jie; Wei, Shimin; Ayres, David W; Smith, Harold T; Tse, Francis L S
2011-09-01
Although it is well known that automation can provide significant improvement in the efficiency of biological sample preparation in quantitative LC-MS/MS analysis, it has not been widely implemented in bioanalytical laboratories throughout the industry. This can be attributed to the lack of a sound strategy and practical procedures in working with robotic liquid-handling systems. Several comprehensive automation assisted procedures for biological sample preparation and method validation were developed and qualified using two types of Hamilton Microlab liquid-handling robots. The procedures developed were generic, user-friendly and covered the majority of steps involved in routine sample preparation and method validation. Generic automation procedures were established as a practical approach to widely implement automation into the routine bioanalysis of samples in support of drug-development programs.
Episodic Contributions to Sequential Control: Learning from a Typist's Touch
ERIC Educational Resources Information Center
Crump, Matthew J. C.; Logan, Gordon D.
2010-01-01
Sequential control over routine action is widely assumed to be controlled by stable, highly practiced representations. Our findings demonstrate that the processes controlling routine actions in the domain of skilled typing can be flexibly manipulated by memory processes coding recent experience with typing particular words and letters. In two…
ERIC Educational Resources Information Center
Wolery, Mark; Brashers, Margaret Sigalove; Neitzel, Jennifer C.
2002-01-01
This article explains how educators can use the ecological congruence assessment process for identifying functional goals for young children with disabilities. Process steps include: teacher collects information about functioning in usual classroom activities, routines, and transitions; summarizes the collected information; and shares the…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anheier, Norman C.; Cannon, Bret D.; Martinez, Alonzo
The International Atomic Energy Agency’s (IAEA’s) long-term research and development plan calls for more cost-effective and efficient safeguard methods to detect and deter misuse of gaseous centrifuge enrichment plants (GCEPs). The IAEA’s current safeguards approaches at GCEPs are based on a combination of routine and random inspections that include environmental sampling and destructive assay (DA) sample collection from UF6 in-process material and selected cylinders. Samples are then shipped offsite for subsequent laboratory analysis. In this paper, a new DA sample collection and onsite analysis approach that could help to meet challenges in transportation and chain of custody for UF6 DAmore » samples is introduced. This approach uses a handheld sampler concept and a Laser Ablation, Laser Absorbance Spectrometry (LAARS) analysis instrument, both currently under development at the Pacific Northwest National Laboratory. A LAARS analysis instrument could be temporarily or permanently deployed in the IAEA control room of the facility, in the IAEA data acquisition cabinet, for example. The handheld PNNL DA sampler design collects and stabilizes a much smaller DA sample mass compared to current sampling methods. The significantly lower uranium mass reduces the sample radioactivity and the stabilization approach diminishes the risk of uranium and hydrogen fluoride release. These attributes enable safe sample handling needed during onsite LAARS assay and may help ease shipping challenges for samples to be processed at the IAEA’s offsite laboratory. The LAARS and DA sampler implementation concepts will be described and preliminary technical viability results presented.« less
An optimized procedure for obtaining DNA from fired and unfired ammunition.
Montpetit, Shawn; O'Donnell, Patrick
2015-07-01
Gun crimes are a significant problem facing law enforcement agencies. Traditional forensic examination of firearms involves comparisons of markings imparted to bullets and cartridge casings during the firing process. DNA testing of casings and cartridges may not be routinely done in crime laboratories due a variety of factors including the typically low amounts of DNA recovered. The San Diego Police Department (SDPD) Crime Laboratory conducted a study to optimize the collection and profiling of DNA from fired and unfired ammunition. The method was optimized to where interpretable DNA results were obtained for 26.1% of the total number of forensic casework evidence samples, and provided some insights into the level of secondary transfer that might be expected from this type of evidence. Briefly detailed are the results from the experimental study and the forensic casework analysis using the optimized process. Mixtures (samples having more DNA types than the loader's known genotype detected or visible at any marker) were obtained in 39.8% of research samples and the likely source of DNA mixtures is discussed. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
LC-MS based analysis of endogenous steroid hormones in human hair.
Gao, Wei; Kirschbaum, Clemens; Grass, Juliane; Stalder, Tobias
2016-09-01
The quantification of endogenous steroid hormone concentrations in hair is increasingly used as a method for obtaining retrospective information on long-term integrated hormone exposure. Several different analytical procedures have been employed for hair steroid analysis, with liquid chromatography-mass spectrometry (LC-MS) being recognized as a particularly powerful analytical tool. Several methodological aspects affect the performance of LC-MS systems for hair steroid analysis, including sample preparation and pretreatment, steroid extraction, post-incubation purification, LC methodology, ionization techniques and MS specifications. Here, we critically review the differential value of such protocol variants for hair steroid hormones analysis, focusing on both analytical quality and practical feasibility issues. Our results show that, when methodological challenges are adequately addressed, LC-MS protocols can not only yield excellent sensitivity and specificity but are also characterized by relatively simple sample processing and short run times. This makes LC-MS based hair steroid protocols particularly suitable as a high-quality option for routine application in research contexts requiring the processing of larger numbers of samples. Copyright © 2016 Elsevier Ltd. All rights reserved.
Analysis of AIS Data of the Recluse Oil Field, Recluse, Wyoming
NASA Technical Reports Server (NTRS)
Dykstra, J. D.; Segal, D. B.
1985-01-01
Airborne Imaging Spectrometer (AIS) data were flown over the Recluse, Wyoming oil field on September 9, 1984. Processing software was developed at Earth Satellite Corporation (EarthSat) for interactive analysis of the AIS data. EarthSat's AIS processing capabilities include destriping, solar irradiance corrections, residual calculations, geometric resampling, equal energy normalization, interactive spectral classifications and a variety of compressive algorithms to reduce the data to 8-bit format with a minimum of information loss. The in-house photolab facilities of EarthSat can routinely produce high-quality color renditions of the enhanced AIS data. A total of 80 lithologic samples were collected under the AIS flight lines. Correlation (within the atmospheric windows) between the laboratory and the AIS spectra of sample sites was generally poor. Reasonable correlation was only possible in large, freshly plowed fields. Mixed pixels and contrast between the natural and sample's surfaces were believed responsible for the poor correlation. Finally, a drift of approximately three channels was observed in the diffraction grating position within the 1.8 to 2.1 micron quadrant.
Nano-plasmonic exosome diagnostics
Im, Hyungsoon; Shao, Huilin; Weissleder, Ralph; Castro, Cesar M.; Lee, Hakho
2015-01-01
Exosomes have emerged as a promising biomarker. These vesicles abound in biofluids and harbor molecular constituents from their parent cells, thereby offering a minimally-invasive avenue for molecular analyses. Despite such clinical potential, routine exosomal analysis, particularly the protein assay, remains challenging, due to requirements for large sample volumes and extensive processing. We have been developing miniaturized systems to facilitate clinical exosome studies. These systems can be categorized into two components: microfluidics for sample preparation and analytical tools for protein analyses. In this report, we review a new assay platform, nano-plasmonic exosome (nPLEX), in which sensing is based on surface plasmon resonance to achieve label-free exosome detection. Looking forward, we also discuss some potential challenges and improvements in exosome studies. PMID:25936957
DOE Office of Scientific and Technical Information (OSTI.GOV)
Growden, Tyler A.; Fakhimi, Parastou; Berger, Paul R., E-mail: pberger@ieee.org
AlN/GaN resonant tunneling diodes grown on low dislocation density semi-insulating bulk GaN substrates via plasma-assisted molecular-beam epitaxy are reported. The devices were fabricated using a six mask level, fully isolated process. Stable room temperature negative differential resistance (NDR) was observed across the entire sample. The NDR exhibited no hysteresis, background light sensitivity, or degradation of any kind after more than 1000 continuous up-and-down voltage sweeps. The sample exhibited a ∼90% yield of operational devices which routinely displayed an average peak current density of 2.7 kA/cm{sup 2} and a peak-to-valley current ratio of ≈1.15 across different sizes.
Isolation of organic acids from large volumes of water by adsorption on macroporous resins
Aiken, George R.; Suffet, I.H.; Malaiyandi, Murugan
1987-01-01
Adsorption on synthetic macroporous resins, such as the Amberlite XAD series and Duolite A-7, is routinely used to isolate and concentrate organic acids from forge volumes of water. Samples as large as 24,500 L have been processed on site by using these resins. Two established extraction schemes using XAD-8 and Duolite A-7 resins are described. The choice of the appropriate resin and extraction scheme is dependent on the organic solutes of interest. The factors that affect resin performance, selectivity, and capacity for a particular solute are solution pH, resin surface area and pore size, and resin composition. The logistical problems of sample handling, filtration, and preservation are also discussed.
Groundwater Remediation and Alternate Energy at White Sands Test Facility
NASA Technical Reports Server (NTRS)
Fischer, Holger
2008-01-01
White Sands Test Facility Core Capabilities: a) Remote Hazardous Testing of Reactive, Explosive, and Toxic Materials and Fluids; b) Hypergolic Fluids Materials and Systems Testing; c) Oxygen Materials and System Testing; d) Hypervelocity Impact Testing; e)Flight Hardware Processing; and e) Propulsion Testing. There is no impact to any drinking water well. Includes public wells and the NASA supply well. There is no public exposure. Groundwater is several hundred feet below ground. No air or surface water exposure. Plume is moving very slowly to the west. Plume Front Treatment system will stop this westward movement. NASA performs on-going monitoring. More than 200 wells and zones are routinely sampled. Approx. 850 samples are obtained monthly and analyzed for over 300 different hazardous chemicals.
Thinking Routines: Replicating Classroom Practices within Museum Settings
ERIC Educational Resources Information Center
Wolberg, Rochelle Ibanez; Goff, Allison
2012-01-01
This article describes thinking routines as tools to guide and support young children's thinking. These learning strategies, developed by Harvard University's Project Zero Classroom, actively engage students in constructing meaning while also understanding their own thinking process. The authors discuss how thinking routines can be used in both…
Learning, Dynamic Capabilities and Operating Routines: A Consumer Package Goods Company
ERIC Educational Resources Information Center
Swift, Peter E.; Hwang, Alvin
2008-01-01
Purpose: This paper seeks to present organizational learning processes of knowledge accumulation, articulation, codification and subsequent routine development in a marketing services organization where judgment and rules of thumb were more the norm than codified knowledge and explicit routines. The case illustrates how organizational learning…
Adams, B W; Mead, G C
1983-12-01
The incidence of Staphylococcus aureus on turkeys sampled at various stages of processing and further-processing was determined on four occasions at each of three different processing plants. For freshly-slaughtered birds, counts from neck skin varied from plant to plant over the range less than 10(2) to greater than 10(5)/g but in all cases the corresponding counts obtained from carcasses sampled after chilling rarely exceeded 10(3)/g and the same was true for samples of mechanically recovered meat (MRM), the final raw product examined. Despite the limited susceptibility of isolates from the different factories to typing by means of either standard human or poultry bacteriophages (55-94% untypable), evidence was obtained with the aid of biotyping for the presence of both human and animal-derived strains. However, some biotypes isolated from MRM were not detected at earlier stages of processing. At one processing plant, an "indigenous' type of S. aureus was clearly demonstrated. It occurred in high numbers in the defeathering machines (up to 10(5)/swab), was found on carcasses at all subsequent stages of processing over the survey period and was shown to survive routine cleaning and disinfection procedures. Isolates of this type produced unusually large amounts of extracellular "slime' in artificial culture. Two of the three processing plants yielded isolates which were enterotoxigenic. Of 55 strains from Plant 1, 60% produced enterotoxin C and all were of the "indigenous' type. In the case of Plant 2, only two type D- and one type F-producing strain were found.
Adams, B. W.; Mead, G. C.
1983-01-01
The incidence of Staphylococcus aureus on turkeys sampled at various stages of processing and further-processing was determined on four occasions at each of three different processing plants. For freshly-slaughtered birds, counts from neck skin varied from plant to plant over the range less than 10(2) to greater than 10(5)/g but in all cases the corresponding counts obtained from carcasses sampled after chilling rarely exceeded 10(3)/g and the same was true for samples of mechanically recovered meat (MRM), the final raw product examined. Despite the limited susceptibility of isolates from the different factories to typing by means of either standard human or poultry bacteriophages (55-94% untypable), evidence was obtained with the aid of biotyping for the presence of both human and animal-derived strains. However, some biotypes isolated from MRM were not detected at earlier stages of processing. At one processing plant, an "indigenous' type of S. aureus was clearly demonstrated. It occurred in high numbers in the defeathering machines (up to 10(5)/swab), was found on carcasses at all subsequent stages of processing over the survey period and was shown to survive routine cleaning and disinfection procedures. Isolates of this type produced unusually large amounts of extracellular "slime' in artificial culture. Two of the three processing plants yielded isolates which were enterotoxigenic. Of 55 strains from Plant 1, 60% produced enterotoxin C and all were of the "indigenous' type. In the case of Plant 2, only two type D- and one type F-producing strain were found. PMID:6663063
Using Six Sigma to improve once daily gentamicin dosing and therapeutic drug monitoring performance.
Egan, Sean; Murphy, Philip G; Fennell, Jerome P; Kelly, Sinead; Hickey, Mary; McLean, Carolyn; Pate, Muriel; Kirke, Ciara; Whiriskey, Annette; Wall, Niall; McCullagh, Eddie; Murphy, Joan; Delaney, Tim
2012-12-01
Safe, effective therapy with the antimicrobial gentamicin requires good practice in dose selection and monitoring of serum levels. Suboptimal therapy occurs with breakdown in the process of drug dosing, serum blood sampling, laboratory processing and level interpretation. Unintentional underdosing may result. This improvement effort aimed to optimise this process in an academic teaching hospital using Six Sigma process improvement methodology. A multidisciplinary project team was formed. Process measures considered critical to quality were defined, and baseline practice was examined through process mapping and audit. Root cause analysis informed improvement measures. These included a new dosing and monitoring schedule, and standardised assay sampling and drug administration timing which maximised local capabilities. Three iterations of the improvement cycle were conducted over a 24-month period. The attainment of serum level sampling in the required time window improved by 85% (p≤0.0001). A 66% improvement in accuracy of dosing was observed (p≤0.0001). Unnecessary dose omission while awaiting level results and inadvertent disruption to therapy due to dosing and monitoring process breakdown were eliminated. Average daily dose administered increased from 3.39 mg/kg to 4.78 mg/kg/day. Using Six Sigma methodology enhanced gentamicin usage process performance. Local process related factors may adversely affect adherence to practice guidelines for gentamicin, a drug which is complex to use. It is vital to adapt dosing guidance and monitoring requirements so that they are capable of being implemented in the clinical environment as a matter of routine. Improvement may be achieved through a structured localised approach with multidisciplinary stakeholder involvement.
Digital Microfluidics Sample Analyzer
NASA Technical Reports Server (NTRS)
Pollack, Michael G.; Srinivasan, Vijay; Eckhardt, Allen; Paik, Philip Y.; Sudarsan, Arjun; Shenderov, Alex; Hua, Zhishan; Pamula, Vamsee K.
2010-01-01
Three innovations address the needs of the medical world with regard to microfluidic manipulation and testing of physiological samples in ways that can benefit point-of-care needs for patients such as premature infants, for which drawing of blood for continuous tests can be life-threatening in their own right, and for expedited results. A chip with sample injection elements, reservoirs (and waste), droplet formation structures, fluidic pathways, mixing areas, and optical detection sites, was fabricated to test the various components of the microfluidic platform, both individually and in integrated fashion. The droplet control system permits a user to control droplet microactuator system functions, such as droplet operations and detector operations. Also, the programming system allows a user to develop software routines for controlling droplet microactuator system functions, such as droplet operations and detector operations. A chip is incorporated into the system with a controller, a detector, input and output devices, and software. A novel filler fluid formulation is used for the transport of droplets with high protein concentrations. Novel assemblies for detection of photons from an on-chip droplet are present, as well as novel systems for conducting various assays, such as immunoassays and PCR (polymerase chain reaction). The lab-on-a-chip (a.k.a., lab-on-a-printed-circuit board) processes physiological samples and comprises a system for automated, multi-analyte measurements using sub-microliter samples of human serum. The invention also relates to a diagnostic chip and system including the chip that performs many of the routine operations of a central labbased chemistry analyzer, integrating, for example, colorimetric assays (e.g., for proteins), chemiluminescence/fluorescence assays (e.g., for enzymes, electrolytes, and gases), and/or conductometric assays (e.g., for hematocrit on plasma and whole blood) on a single chip platform.
Borras, Eva; Aksenov, Alexander A; Baird, Mark; Novick, Brittany; Schivo, Michael; Zamuruyev, Konstantin O; Pasamontes, Alberto; Parry, Celeste; Foutouhi, Soraya; Venn-Watson, Stephanie; Weimer, Bart C; Davis, Cristina E
2017-11-01
Monitoring health conditions is essential to detect early asymptomatic stages of a disease. To achieve this, blood, urine and breath samples are commonly used as a routine clinical diagnostic. These samples offer the opportunity to detect specific metabolites related to diseases and provide a better understanding of their development. Although blood samples are commonly used routinely to monitor health, the implementation of a relatively noninvasive technique, such as exhaled breath condensate (EBC) analysis, may further benefit the well-being of both humans and other animals. EBC analysis can be used to track possible physical or biochemical alterations caused by common diseases of the bottlenose dolphin (Tursiops truncatus), such as infections or inflammatory-mediated processes. We have used an untargeted metabolomic method with liquid chromatography-mass spectrometry analysis of EBC samples to determine biomarkers related to disease development. In this study, five dolphins under human care were followed up for 1 year. We collected paired blood, physical examination information, and EBC samples. We then statistically correlated this information to predict specific health alterations. Three dolphins provided promising case study information about biomarkers related to cutaneous infections, respiratory infections, dental disease, or hormonal changes (pregnancy). The use of complementary liquid chromatography platforms, with hydrophilic interaction chromatography and reverse-phased columns, allowed us to detect a wide spectrum of EBC biomarker compounds that could be related to these health alterations. Moreover, these two analytical techniques not only provided complementary metabolite information but in both cases they also provided promising diagnostic information for these health conditions. Graphical abstract Collection of the exhaled condensed breath from a bottlenose dolphin from U.S. Navy Marine Mammal Program (MMP).
Boers, Stefan A; Hiltemann, Saskia D; Stubbs, Andrew P; Jansen, Ruud; Hays, John P
2018-06-01
Microbiota profiling has the potential to greatly impact on routine clinical diagnostics by detecting DNA derived from live, fastidious, and dead bacterial cells present within clinical samples. Such results could potentially be used to benefit patients by influencing antibiotic prescribing practices or to generate new classical-based diagnostic methods, e.g., culture or PCR. However, technical flaws in 16S rRNA gene next-generation sequencing (NGS) protocols, together with the requirement for access to bioinformatics, currently hinder the introduction of microbiota analysis into clinical diagnostics. Here, we report on the development and evaluation of an "end-to-end" microbiota profiling platform (MYcrobiota), which combines our previously validated micelle PCR/NGS (micPCR/NGS) methodology with an easy-to-use, dedicated bioinformatics pipeline. The newly designed bioinformatics pipeline processes micPCR/NGS data automatically and summarizes the results in interactive, but simple web reports. In order to explore the utility of MYcrobiota in clinical diagnostics, 47 clinical samples (40 "damaged skin" samples and 7 synovial fluids) were investigated using routine bacterial culture as comparator. MYcrobiota confirmed the presence of bacterial DNA in 37/37 culture-positive samples and detected bacterial taxa in 2/10 culture-negative samples. Moreover, 36/38 potentially relevant aerobic bacterial taxa and 3/3 mixtures of anaerobic bacteria were identified using culture and MYcrobiota, with the sensitivity and specificity being 95%. Interestingly, the majority of the 448 bacterial taxa identified using MYcrobiota were not identified using culture, which could potentially have an impact on clinical decision-making. Taken together, the development of MYcrobiota is a promising step towards the introduction of microbiota analysis into clinical diagnostic laboratories.
Pruvost, A; Becher, F; Bardouille, P; Guerrero, C; Creminon, C; Delfraissy, J F; Goujard, C; Grassi, J; Benech, H
2001-01-01
The objective was to develop and validate a routine assay for active intracellular anabolites of stavudine (d4T), a nucleoside reverse transcriptase inhibitor in human PBMC, applicable to pharmacokinetic studies and treatment monitoring. This was achieved using liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS), which theoretically allies optimum sensitivity, specificity and high sample throughput. After cellular lysis in a Tris/methanol buffer, the extract spiked with 2[H(8)]-ATP (internal standard) is directly injected into the LC/MS/MS system. Phosphorylated metabolites of d4T as well as deoxythymidine-triphosphate, the competitor on the reverse transcriptase, are separated from d4T on a reverse-phase microbore column with ion pairing. The detection is performed in the multiple reaction monitoring (MRM) mode after drug ionisation in negative mode electrospray. The limit of quantitation for d4T-TP was 138 fmol per 7 mL blood (9.8 fmol per 10(6) cells) and CV% for repeatability and intermediate precision were lower than 15%. Stability of compounds was checked before and during the process of isolation of PBMC. Cellular samples from several d4T-treated patients were successfully analysed using this method and d4T-triphosphate and deoxythymidine triphosphate were recovered. In conclusion, we have developed and validated a routine LC/MS/MS method that allows the simultaneous determination of mono-, di- and triphosphorylated anabolites of d4T in PBMC as well as the natural corresponding triphosphate in one analysis. For the first time, the chain terminator ratio (d4T-TP/dT-TP) could be directly measured. This method can be used simply and routinely on more than 35 samples per day. Extension to other nucleoside analogues is under development. Copyright 2001 John Wiley & Sons, Ltd.
Cahill, J.D.; Furlong, E.T.; Burkhardt, M.R.; Kolpin, D.; Anderson, L.G.
2004-01-01
Commonly used prescription and over-the-counter pharmaceuticals are possibly present in surface- and ground-water samples at ambient concentrations less than 1 μg/L. In this report, the performance characteristics of a combined solid-phase extraction isolation and high-performance liquid chromatography–electrospray ionization mass spectrometry (HPLC–ESI-MS) analytical procedure for routine determination of the presence and concentration of human-health pharmaceuticals are described. This method was developed and used in a recent national reconnaissance of pharmaceuticals in USA surface waters. The selection of pharmaceuticals evaluated for this method was based on usage estimates, resulting in a method that contains compounds from diverse chemical classes, which presents challenges and compromises when applied as a single routine analysis. The method performed well for the majority of the 22 pharmaceuticals evaluated, with recoveries greater than 60% for 12 pharmaceuticals. The recoveries of angiotensin-converting enzyme inhibitors, a histamine (H2) receptor antagonist, and antihypoglycemic compound classes were less than 50%, but were retained in the method to provide information describing the potential presence of these compounds in environmental samples and to indicate evidence of possible matrix enhancing effects. Long-term recoveries, evaluated from reagent-water fortifications processed over 2 years, were similar to initial method performance. Method detection limits averaged 0.022 μg/L, sufficient for expected ambient concentrations. Compound-dependent matrix effects on HPLC/ESI-MS analysis, including enhancement and suppression of ionization, were observed as a 20–30% increase in measured concentrations for three compounds and greater than 50% increase for two compounds. Changing internal standard and more frequent ESI source maintenance minimized matrix effects. Application of the method in the national survey demonstrates that several pharmaceuticals are routinely detected at 0.010–0.100 μg/L concentrations.
REPRESENTATIVE SAMPLING AND ANALYSIS OF HETEROGENEOUS SOILS
Standard sampling and analysis methods for hazardous substances in contaminated soils currently are available and routinely employed. Standard methods inherently assume a homogeneous soil matrix and contaminant distribution; therefore only small sample quantities typically are p...
SU-E-J-85: Leave-One-Out Perturbation (LOOP) Fitting Algorithm for Absolute Dose Film Calibration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, A; Ahmad, M; Chen, Z
2014-06-01
Purpose: To introduce an outliers-recognition fitting routine for film dosimetry. It cannot only be flexible with any linear and non-linear regression but also can provide information for the minimal number of sampling points, critical sampling distributions and evaluating analytical functions for absolute film-dose calibration. Methods: The technique, leave-one-out (LOO) cross validation, is often used for statistical analyses on model performance. We used LOO analyses with perturbed bootstrap fitting called leave-one-out perturbation (LOOP) for film-dose calibration . Given a threshold, the LOO process detects unfit points (“outliers”) compared to other cohorts, and a bootstrap fitting process follows to seek any possibilitiesmore » of using perturbations for further improvement. After that outliers were reconfirmed by a traditional t-test statistics and eliminated, then another LOOP feedback resulted in the final. An over-sampled film-dose- calibration dataset was collected as a reference (dose range: 0-800cGy), and various simulated conditions for outliers and sampling distributions were derived from the reference. Comparisons over the various conditions were made, and the performance of fitting functions, polynomial and rational functions, were evaluated. Results: (1) LOOP can prove its sensitive outlier-recognition by its statistical correlation to an exceptional better goodness-of-fit as outliers being left-out. (2) With sufficient statistical information, the LOOP can correct outliers under some low-sampling conditions that other “robust fits”, e.g. Least Absolute Residuals, cannot. (3) Complete cross-validated analyses of LOOP indicate that the function of rational type demonstrates a much superior performance compared to the polynomial. Even with 5 data points including one outlier, using LOOP with rational function can restore more than a 95% value back to its reference values, while the polynomial fitting completely failed under the same conditions. Conclusion: LOOP can cooperate with any fitting routine functioning as a “robust fit”. In addition, it can be set as a benchmark for film-dose calibration fitting performance.« less
Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.
2016-01-01
Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468
RAPID DETERMINATION OF RA-226 IN ENVIRONMENTAL SAMPLES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, S.
2012-01-03
A new rapid method for the determination of {sup 226}Ra in environmental samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for emergency response or routine sample analyses. The need for rapid analyses in the event of a Radiological Dispersive Device or Improvised Nuclear Device event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. {sup 226}Ra (T1/2 = 1,620 years) is one of the mostmore » toxic of the long-lived alpha-emitters present in the environment due to its long life and its tendency to concentrate in bones, which increases the internal radiation dose of individuals. The new method to determine {sup 226}Ra in environmental samples utilizes a rapid sodium hydroxide fusion method for solid samples, calcium carbonate precipitation to preconcentrate Ra, and rapid column separation steps to remove interferences. The column separation process uses cation exchange resin to remove large amounts of calcium, Sr Resin to remove barium and Ln Resin as a final purification step to remove {sup 225}Ac and potential interferences. The purified {sup 226}Ra sample test sources are prepared using barium sulfate microprecipitation in the presence of isopropanol for counting by alpha spectrometry. The method showed good chemical recoveries and effective removal of interferences. The determination of {sup 226}Ra in environmental samples can be performed in less than 16 h for vegetation, concrete, brick, soil, and air filter samples with excellent quality for emergency or routine analyses. The sample preparation work takes less than 6 h. {sup 225}Ra (T1/2 = 14.9 day) tracer is used and the {sup 225}Ra progeny {sup 217}At is used to determine chemical yield via alpha spectrometry. The rapid fusion technique is a rugged sample digestion method that ensures that any refractory radium particles are effectively digested. The preconcentration and column separation steps can also be applied to aqueous samples with good results.« less
Innovation adoption processes for third party property management companies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shockman, Chris; Piette, Mary Ann
2000-07-01
Innovation adoption studies have never been applied to third party property management companies. These companies manage buildings for a fee as their primary business. Property management companies are influential in the adoption process for new technologies because they act as gatekeepers for technical information. This study analyzes radical and routine adoption process that are found in large, professionally operated property management companies. The process is explicated. The technical managers, and their role as technology gate keepers, are described. The distinction to the technical managers between routine and radical technology is that routine technologies do something in a new way andmore » radical technologies do something new. Observations concerning evaluation and adoption of information technologies are described. The findings suggest methods of successfully tailoring and introducing technologies to this market.« less
NASA Astrophysics Data System (ADS)
Namburi, Devendra K.; Shi, Yunhua; Palmer, Kysen G.; Dennis, Anthony R.; Durrell, John H.; Cardwell, David A.
2016-09-01
A fundamental requirement of the fabrication of high performing, (RE)-Ba-Cu-O bulk superconductors is achieving a single grain microstructure that exhibits good flux pinning properties. The top seeded melt growth (TSMG) process is a well-established technique for the fabrication of single grain (RE)BCO bulk samples and is now applied routinely by a number of research groups around the world. The introduction of a buffer layer to the TSMG process has been demonstrated recently to improve significantly the general reliability of the process. However, a number of growth-related defects, such as porosity and the formation of micro-cracks, remain inherent to the TSMG process, and are proving difficult to eliminate by varying the melt process parameters. The seeded infiltration and growth (SIG) process has been shown to yield single grain samples that exhibit significantly improved microstructures compared to the TSMG technique. Unfortunately, however, SIG leads to other processing challenges, such as the reliability of fabrication, optimisation of RE2BaCuO5 (RE-211) inclusions (size and content) in the sample microstructure, practical oxygenation of as processed samples and, hence, optimisation of the superconducting properties of the bulk single grain. In the present paper, we report the development of a near-net shaping technique based on a novel two-step, buffer-aided top seeded infiltration and growth (BA-TSIG) process, which has been demonstrated to improve greatly the reliability of the single grain growth process and has been used to fabricate successfully bulk, single grain (RE)BCO superconductors with improved microstructures and superconducting properties. A trapped field of ˜0.84 T and a zero field current density of 60 kA cm-2 have been measured at 77 K in a bulk, YBCO single grain sample of diameter 25 mm processed by this two-step BA-TSIG technique. To the best of our knowledge, this value of trapped field is the highest value ever reported for a sample fabricated by an infiltration and growth process. In this study we report the successful fabrication of 14 YBCO samples, with diameters of up to 32 mm, by this novel technique with a success rate of greater than 92%.
[Satisfaction with life, victimization, and perception of insecurity in Morelos].
Martínez-Ferrer, Belén; Ávila-Guerrero, María Elena; Vera-Jiménez, Jesús Alejandro; Bahena-Rivera, Alejandro; Musitu-Ochoa, Gonzalo
2016-01-01
To examines the influence of victimization, perceived insecurity and restrictions on daily routines in life satisfaction. Participants were 7535 (50.2% men) aged between 12 and 60, selected from a proportional stratified sampling. MANOVA and polytomous logistic regression model were calculated. We found significant differences in victimization, perceived insecurity and restrictions on daily routines in relation with life satisfaction levels. Also, physical protective measures, control of personal information, perception of insecurity in public areas and restrictions on daily routines were related to lower levels of satisfaction with life. Lowest levels of satisfaction with life were associated with victimization, perception of insecurity in public areas, and restrictions on daily routines.
Volatile metal species in coal combustion flue gas.
Pavageau, Marie-Pierre; Pécheyran, Christophe; Krupp, Eva M; Morin, Anne; Donard, Olivier F X
2002-04-01
Metals are released in effluents of most of combustion processes and are under intensive regulations. To improve our knowledge of combustion process and their resulting emission of metal to the atmosphere, we have developed an approach allowing usto distinguish between gaseous and particulate state of the elements emitted. This study was conducted on the emission of volatile metallic species emitted from a coal combustion plant where low/medium volatile coal (high-grade ash) was burnt. The occurrence of volatile metal species emission was investigated by cryofocusing sampling procedure and detection using low-temperature packed-column gas chromatography coupled with inductively coupled plasma-mass spectrometry as multielement detector (LT-GC/ICP-MS). Samples were collected in the stack through the routine heated sampling line of the plant downstream from the electrostatic precipitator. The gaseous samples were trapped with a cryogenic device and analyzed by LT-GC/ICP-MS. During the combustion process, seven volatile metal species were detected: three for Se, one for Sn, two for Hg, and one for Cu. Thermodynamic calculations and experimental metal species spiking experiments suggest that the following volatile metal species are present in the flue gas during the combustion process: COSe, CSSe, CSe2, SeCl2, Hg0, HgCl2, CuO-CuSO4 or CuSO4 x H2O, and SnO2 or SnCl2. The quantification of volatile species was compared to results traditionally obtained by standardized impinger-based sampling and analysis techniques recommended for flue gas combustion characterization. Results showed that concentrations obtained with the standard impinger approach are at least 10 times higher than obtained with cryogenic sampling, suggesting the trapping microaerosols in the traditional methods. Total metal concentrations in particles are also reported and discussed.
Stults, Cheryl L M; Ansell, Jennifer M; Shaw, Arthur J; Nagao, Lee M
2015-02-01
Polymeric materials are often used in pharmaceutical packaging, delivery systems, and manufacturing components. There is continued concern that chemical entities from polymeric components may leach into various dosage forms, particularly those that are comprised of liquids such as parenterals, injectables, ophthalmics, and inhalation products. In some cases, polymeric components are subjected to routine extractables testing as a control measure. To reduce the risk of discovering leachables during stability studies late in the development process, or components that may fail extractables release criteria, it is proposed that extractables testing on polymer resins may be useful as a screening tool. Two studies have been performed to evaluate whether the extractables profile generated from a polymer resin is representative of the extractables profile of components made from that same resin. The ELSIE Consortium pilot program examined polyvinyl chloride and polyethylene, and another study evaluated polypropylene and a copolymer of polycarbonate and acrylonitrile butadiene styrene. The test materials were comprised of polymer resin and processed resin or molded components. Volatile, semi-volatile, and nonvolatile chemical profiles were evaluated after headspace sampling and extraction with solvents of varying polarity and pH. The findings from these studies indicate that there may or may not be differences between extractables profiles obtained from resins and processed forms of the resin depending on the type of material, the compounds of interest, and extraction conditions used. Extractables testing of polymer resins is useful for material screening and in certain situations may replace routine component testing.
Finch, Tracy L; Mair, Frances S; O'Donnell, Catherine; Murray, Elizabeth; May, Carl R
2012-05-17
Although empirical and theoretical understanding of processes of implementation in health care is advancing, translation of theory into structured measures that capture the complex interplay between interventions, individuals and context remain limited. This paper aimed to (1) describe the process and outcome of a project to develop a theory-based instrument for measuring implementation processes relating to e-health interventions; and (2) identify key issues and methodological challenges for advancing work in this field. A 30-item instrument (Technology Adoption Readiness Scale (TARS)) for measuring normalisation processes in the context of e-health service interventions was developed on the basis on Normalization Process Theory (NPT). NPT focuses on how new practices become routinely embedded within social contexts. The instrument was pre-tested in two health care settings in which e-health (electronic facilitation of healthcare decision-making and practice) was used by health care professionals. The developed instrument was pre-tested in two professional samples (N=46; N=231). Ratings of items representing normalisation 'processes' were significantly related to staff members' perceptions of whether or not e-health had become 'routine'. Key methodological challenges are discussed in relation to: translating multi-component theoretical constructs into simple questions; developing and choosing appropriate outcome measures; conducting multiple-stakeholder assessments; instrument and question framing; and more general issues for instrument development in practice contexts. To develop theory-derived measures of implementation process for progressing research in this field, four key recommendations are made relating to (1) greater attention to underlying theoretical assumptions and extent of translation work required; (2) the need for appropriate but flexible approaches to outcomes measurement; (3) representation of multiple perspectives and collaborative nature of work; and (4) emphasis on generic measurement approaches that can be flexibly tailored to particular contexts of study.
40 CFR 63.2251 - What are the requirements for the routine control device maintenance exemption?
Code of Federal Regulations, 2010 CFR
2010-07-01
... the routine control device maintenance exemption? (a) You may request a routine control device..., explain why the maintenance cannot be accomplished during process shutdowns, describe how you plan to make... device is used to control a green rotary dryer, tube dryer, rotary strand dryer, or pressurized refiner...
Hiitiö, Heidi; Riva, Rauna; Autio, Tiina; Pohjanvirta, Tarja; Holopainen, Jani; Pyörälä, Satu; Pelkonen, Sinikka
2015-05-01
Reliable identification of the aetiological agent is crucial in mastitis diagnostics. Real-time PCR is a fast, automated tool for detecting the most common udder pathogens directly from milk. In this study aseptically taken quarter milk samples were analysed with a real-time PCR assay (Thermo Scientific PathoProof Mastitis Complete-12 Kit, Thermo Fisher Scientific Ltd.) and by semi-quantitative, in-depth bacteriological culture (BC). The aim of the study was to evaluate the diagnostic performance of the real-time PCR assay in routine use. A total of 294 quarter milk samples from routine mastitis cases were cultured in the national reference laboratory of Finland and examined with real-time PCR. With BC, 251 out of 294 (85.7%) of the milk samples had at least one colony on the plate and 38 samples were considered contaminated. In the PCR mastitis assay, DNA of target species was amplified in 244 samples out of 294 (83.0%). The most common bacterial species detected in the samples, irrespective of the diagnostic method, was the coagulase negative staphylococci (CNS) group (later referred as Staphylococcus spp.) followed by Staphylococcus aureus. Sensitivity (Se) and specificity (Sp) for the PCR assay to provide a positive Staph. aureus result was 97.0 and 95.8% compared with BC. For Staphylococcus spp., the corresponding figures were 86.7 and 75.4%. Our results imply that PCR performed well as a diagnostic tool to detect Staph. aureus but may be too nonspecific for Staphylococcus spp. in routine use with the current cut-off Ct value (37.0). Using PCR as the only microbiological method for mastitis diagnostics, clinical relevance of the results should be carefully considered before further decisions, for instance antimicrobial treatment, especially when minor pathogens with low amount of DNA have been detected. Introducing the concept of contaminated samples should also be considered.
Malapelle, Umberto; Pisapia, Pasquale; Sgariglia, Roberta; Vigliar, Elena; Biglietto, Maria; Carlomagno, Chiara; Giuffrè, Giuseppe; Bellevicine, Claudio; Troncone, Giancarlo
2016-09-01
The incidence of RAS/RAF/PI3KA and TP53 gene mutations in colorectal cancer (CRC) is well established. Less information, however, is available on other components of the CRC genomic landscape, which are potential CRC prognostic/predictive markers. Following a previous validation study, ion-semiconductor next-generation sequencing (NGS) was employed to process 653 routine CRC samples by a multiplex PCR targeting 91 hotspot regions in 22 CRC significant genes. A total of 796 somatic mutations in 499 (76.4%) tumours were detected. Besides RAS/RAF/PI3KA and TP53, other 12 genes showed at least one mutation including FBXW7 (6%), PTEN (2.8%), SMAD4 (2.1%), EGFR (1.2%), CTNNB1 (1.1%), AKT1 (0.9%), STK11 (0.8%), ERBB2 (0.6%), ERBB4 (0.6%), ALK (0.2%), MAP2K1 (0.2%) and NOTCH1 (0.2%). In a routine diagnostic setting, NGS had the potential to generate robust and comprehensive genetic information also including less frequently mutated genes potentially relevant for prognostic assessments or for actionable treatments. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Urinary lithogenesis risk tests: comparison of a commercial kit and a laboratory prototype test.
Grases, Félix; Costa-Bauzá, Antonia; Prieto, Rafel M; Arrabal, Miguel; De Haro, Tomás; Lancina, Juan A; Barbuzano, Carmen; Colom, Sergi; Riera, Joaquín; Perelló, Joan; Isern, Bernat; Sanchis, Pilar; Conte, Antonio; Barragan, Fernando; Gomila, Isabel
2011-11-01
Renal stone formation is a multifactorial process depending in part on urine composition. Other parameters relate to structural or pathological features of the kidney. To date, routine laboratory estimation of urolithiasis risk has been based on determination of urinary composition. This process requires collection of at least two 24 h urine samples, which is tedious for patients. The most important feature of urinary lithogenic risk is the balance between various urinary parameters, although unknown factors may be involved. The objective of this study was to compare data obtained using a commercial kit with those of a laboratory prototype, using a multicentre approach, to validate the utility of these methods in routine clinical practice. A simple new commercial test (NefroPlus®; Sarstedt AG & Co., Nümbrecht, Germany) evaluating the capacity of urine to crystallize calcium salts, and thus permitting detection of patients at risk for stone development, was compared with a prototype test previously described by this group. Urine of 64 volunteers produced during the night was used in these comparisons. The commercial test was also used to evaluate urine samples of 83 subjects in one of three hospitals. Both methods were essentially in complete agreement (98%) with respect to test results. The multicentre data were: sensitivity 94.7%; specificity 76.9%; positive predictive value (lithogenic urine) 90.0%; negative predictive value (non-lithogenic urine) 87.0%; test efficacy 89.2%. The new commercial NefroPlus test offers fast and cheap evaluation of the overall risk of development of urinary calcium-containing calculi.
Multiplexing a high-throughput liability assay to leverage efficiencies.
Herbst, John; Anthony, Monique; Stewart, Jeremy; Connors, David; Chen, Taosheng; Banks, Martyn; Petrillo, Edward W; Agler, Michele
2009-06-01
In order to identify potential cytochrome P-450 3A4 (drug-metabolizing enzyme) inducers at an early stage of the drug discovery process, a cell-based transactivation high-throughput luciferase reporter assay for the human pregnane X receptor (PXR) in HepG2 cells has been implemented and multiplexed with a viability end point for data interpretation, as part of a Lead Profiling portfolio of assays. As a routine part of Lead Profiling operations, assays are periodically evaluated for utility as well as for potential improvements in technology or process. We used a recent evaluation of our PXR-transactivation assay as a model for the application of Lean Thinking-based process analysis to lab-bench assay optimization and automation. This resulted in the development of a 384-well multiplexed homogeneous assay simultaneously detecting PXR transactivation and HepG2 cell cytotoxicity. In order to multiplex fluorescent and luminescent read-outs, modifications to each assay were necessary, which included optimization of multiple assay parameters such as cell density, plate type, and reagent concentrations. Subsequently, a set of compounds including known cytotoxic compounds and PXR inducers were used to validate the multiplexed assay. Results from the multiplexed assay correlate well with those from the singleplexed assay formats measuring PXR transactivation and viability separately. Implementation of the multiplexed assay for routine compound profiling provides improved data quality, sample conservation, cost savings, and resource efficiencies.
Józwa, Wojciech; Czaczyk, Katarzyna
2012-04-02
Flow cytometry constitutes an alternative for traditional methods of microorganisms identification and analysis, including methods requiring cultivation step. It enables the detection of pathogens and other microorganisms contaminants without the need to culture microbial cells meaning that the sample (water, waste or food e.g. milk, wine, beer) may be analysed directly. This leads to a significant reduction of time required for analysis allowing monitoring of production processes and immediate reaction in case of contamination or any disruption occurs. Apart from the analysis of raw materials or products on different stages of manufacturing process, the flow cytometry seems to constitute an ideal tool for the assessment of microbial contamination on the surface of technological lines. In the present work samples comprising smears from 3 different surfaces of technological lines from fruit and vegetable processing company from Greater Poland were analysed directly with flow cytometer. The measured parameters were forward and side scatter of laser light signals allowing the estimation of microbial cell contents in each sample. Flow cytometric analysis of the surface of food industry production lines enable the preliminary evaluation of microbial contamination within few minutes from the moment of sample arrival without the need of sample pretreatment. The presented method of fl ow cytometric initial evaluation of microbial state of food industry technological lines demonstrated its potential for developing a robust, routine method for the rapid and labor-saving detection of microbial contamination in food industry.
NASA Astrophysics Data System (ADS)
Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi
2014-06-01
Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.
Quality Assurance of Samples and Processes in the Spanish Renal Research Network (REDinREN) Biobank.
Calleros-Basilio, Laura; Cortés, María Alicia; García-Jerez, Andrea; Luengo-Rodríguez, Alicia; Orozco-Agudo, Ana; Valdivielso, José Manuel; Rodríguez-Puyol, Diego; Rodríguez-Puyol, Manuel
2016-12-01
Biobanks are useful platforms to build bridges between basic, translational, and clinical research and clinical care. They are repositories of high-quality human biological samples ideal for evaluating their histological characteristics and also their genome, transcriptome, and proteome. The Spanish Renal Research Network Biobank contains more than 76,500 well-preserved frozen samples of a wide variety of kidney diseases, collected from 5450 patients seen by over 70 nephrology services throughout the Spanish territory. To determine and to report the results of the quality control of samples and processes conducted in our biobank, implemented in accordance with the requirements of the ISO 9001:2008 international standard. Two types of quality controls were performed: (1) systematic, that is, measurement of viable peripheral blood mononuclear cells (PBMCs) obtained and purity of nucleic acids and (2) ad-hoc, that is, viability of thawed PBMC, DNA extraction process reproducibility, and the integrity and functionality of nucleic acids, implemented on a routine basis. PBMC isolation by Ficoll yielded reproducible results and its cryopreserved viability was >90%. Acceptable A260/A280 ratios were obtained for the vast majority of the DNA (n = 2328) and RNA (n = 78) samples analyzed. DNA integrity was demonstrated by agarose gels and by β-globulin gene polymerase chain reaction (PCR) amplification of 1327 and 989 bp fragments. DNA of acceptable quality had at least three bands of β-globulin amplified obtained (n = 26/30). RNA integrity number (RIN) determinations obtained RIN numbers ≥7 (n = 87/96). The amplifiability of nucleic acids was confirmed by qPCR and RT-qPCR of β-actin and GAPDH genes. Long storage or delayed processing time did not affect the quality of the samples analyzed. The processes of DNA extraction also yielded reproducible results. These results clearly indicate that our PBMC, DNA, and RNA stored samples meet the required quality standards to be used for biomedical research, ensuring their long-term preservation.
NASA Astrophysics Data System (ADS)
Cook, Grant O.; Sorensen, Carl D.
2013-12-01
Partial transient liquid-phase (PTLP) bonding is currently an esoteric joining process with limited applications. However, it has preferable advantages compared with typical joining techniques and is the best joining technique for certain applications. Specifically, it can bond hard-to-join materials as well as dissimilar material types, and bonding is performed at comparatively low temperatures. Part of the difficulty in applying PTLP bonding is finding suitable interlayer combinations (ICs). A novel interlayer selection procedure has been developed to facilitate the identification of ICs that will create successful PTLP bonds and is explained in a companion article. An integral part of the selection procedure is a filtering routine that identifies all possible ICs for a given application. This routine utilizes a set of customizable parameters that are based on key characteristics of PTLP bonding. These parameters include important design considerations such as bonding temperature, target remelting temperature, bond solid type, and interlayer thicknesses. The output from this routine provides a detailed view of each candidate IC along with a broad view of the entire candidate set, greatly facilitating the selection of ideal ICs. This routine provides a new perspective on the PTLP bonding process. In addition, the use of this routine, by way of the accompanying selection procedure, will expand PTLP bonding as a viable joining process.
Polley, Spencer D.; Mori, Yasuyoshi; Watson, Julie; Perkins, Mark D.; González, Iveth J.; Notomi, Tsugunori; Chiodini, Peter L.; Sutherland, Colin J.
2010-01-01
Loop-mediated isothermal amplification (LAMP) of DNA offers the ability to detect very small quantities of pathogen DNA following minimal tissue sample processing and is thus an attractive methodology for point-of-care diagnostics. Previous attempts to diagnose malaria by the use of blood samples and LAMP have targeted the parasite small-subunit rRNA gene, with a resultant sensitivity for Plasmodium falciparum of around 100 parasites per μl. Here we describe the use of mitochondrial targets for LAMP-based detection of any Plasmodium genus parasite and of P. falciparum specifically. These new targets allow routine amplification from samples containing as few as five parasites per μl of blood. Amplification is complete within 30 to 40 min and is assessed by real-time turbidimetry, thereby offering rapid diagnosis with greater sensitivity than is achieved by the most skilled microscopist or antigen detection using lateral flow immunoassays. PMID:20554824
Lintern, Melvyn; Anand, Ravi; Ryan, Chris; Paterson, David
2013-01-01
Eucalyptus trees may translocate Au from mineral deposits and support the use of vegetation (biogeochemical) sampling in mineral exploration, particularly where thick sediments dominate. However, biogeochemistry has not been routinely adopted partly because biotic mechanisms of Au migration are poorly understood. For example, although Au has been previously measured in plant samples, there has been doubt as to whether it was truly absorbed rather than merely adsorbed on the plant surface as aeolian contamination. Here we show the first evidence of particulate Au within natural specimens of living biological tissue (not from laboratory experimentation). This observation conclusively demonstrates active biogeochemical adsorption of Au and provides insight into its behaviour in natural samples. The confirmation of biogeochemical adsorption of Au, and of a link with abiotic processes, promotes confidence in an emerging technique that may lead to future exploration success and maintain continuity of supply. PMID:24149278
Investigation of Tank 241-AN-101 Floating Solids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraft, Douglas P.; Meznarich, H. K.
Tank 241-AN-101 is the receiver tank for retrieval of several C-Farms waste tanks, including Tanks 241-C-102 and 241-C-111. Tank 241 C 111 received first-cycle decontamination waste from the bismuth phosphate process and Plutonium and Uranium Extraction cladding waste, as well as hydraulic fluid. Three grab samples, 1AN-16-01, 1AN-16-01A, and 1AN-16-01B, were collected at the surface of Tank 241-AN-101 on April 25, 2016, after Tank 241-C-111 retrieval was completed. Floating solids were observed in the three grab samples in the 11A hot cell after the samples were received at the 222-S Laboratory. Routine chemical analyses, solid phase characterization on the floatingmore » and settled solids, semivolatile organic analysis mainly on the aqueous phase for identification of degradation products of hydraulic fluids were performed. Investigation of the floating solids is reported.« less
NASA Astrophysics Data System (ADS)
Newell, R. E.; Wu, M.-F.
It is noted that the Global Atmospheric Sampling Program (GASP) was intended to establish global baseline values of selected atmospheric constituents that could be used for studies of the dynamics of the sampled region as well as for modeling purposes. Instrument packages were carried on four Boeing 747 aircraft in routine commercial service. Carbon monoxide and ozone data were collected simultaneously from early 1977 to early 1979 when GASP terminated. CO was measured with an infrared absorption analyzer using dual isotope fluorescence. Ozone was measured via absorption of UV light. Correlations between the CO and the O3 are tabulated; they are clearly negative for both troposphere and stratosphere in middle latitudes, indicating that transport processes between the stratosphere and troposphere (discussed) dominate. But in the low latitude troposphere the correlations are positive, indicating the possible influence of photochemical effects.
Griffin, M.S.; Martin, G.R.; White, K.D.
1994-01-01
This report describes selected data-collection activities and the associated data collected during the Kentucky River Basin pilot study of the U.S. Geological Survey's National Water-Quality Assessment Program. The data are intended to provide a nationally consistent description and improved understanding of current water quality in the basin. The data were collected at seven fixed stations that represent stream cross sections where constituent transport and water-quality trends can be evaluated. The report includes descriptions of (1) the basin; (2) the design of the fixed-station network; (3) the fixed-station sites; (4) the physical and chemical measurements; (5) the methods of sample collection, processing, and analysis; and (6) the quality-assurance and quality-control procedures. Water-quality data collected at the fixed stations during routine periodic sampling and supplemental high-flow sampling from April 1987 to August 1991 are presented.
Zuo, Shuyan; Cairns, Lisa; Hutin, Yvan; Liang, Xiaofeng; Tong, Yibing; Zhu, Qing; Zhang, Dayong; Lee, Lisa A; Strebel, Peter; Quick, Linda
2015-04-21
To develop a successful model for accelerating measles elimination in poor areas of China, we initiated a seven-year project in Guizhou, one of the poorest provinces, with reported highest measles incidence of 360 per million population in 2002. Project strategies consisted of strengthening routine immunization services, enforcement of school entry immunization requirements at kindergarten and school, conducting supplemental measles immunization activities (SIAs), and enhancing measles surveillance. We measured coverage of measles containing vaccines (MCV) by administrative reporting and population-based sample surveys, systematic random sampling surveys, and convenience sampling surveys for routine immunization services, school entry immunization, and SIAs respectively. We measured impact using surveillance based measles incidence. Routine immunization coverage of the 1st dose of MCV (MCV1) increased from 82% to 93%, while 2nd dose of MCV (MCV2) coverage increased from 78% to 91%. Enforcement of school entry immunization requirements led to an increase in MCV2 coverage from 36% on primary school entry in 2004 to 93% in 2009. Province-wide SIAs achieved coverage greater than 90%. The reported annual incidence of measles dropped from 200 to 300 per million in 2003 to 6 per million in 2009, and sustained at 0.9-2.2 per million in 2010-2013. This project found that a package of strategies including periodic SIAs, strengthened routine immunization, and enforcing school entry immunization requirements, was an effective approach toward achieving and sustaining measles elimination in less-developed area of China. Copyright © 2015. Published by Elsevier Ltd.
Daily life activity routine discovery in hemiparetic rehabilitation patients using topic models.
Seiter, J; Derungs, A; Schuster-Amft, C; Amft, O; Tröster, G
2015-01-01
Monitoring natural behavior and activity routines of hemiparetic rehabilitation patients across the day can provide valuable progress information for therapists and patients and contribute to an optimized rehabilitation process. In particular, continuous patient monitoring could add type, frequency and duration of daily life activity routines and hence complement standard clinical scores that are assessed for particular tasks only. Machine learning methods have been applied to infer activity routines from sensor data. However, supervised methods require activity annotations to build recognition models and thus require extensive patient supervision. Discovery methods, including topic models could provide patient routine information and deal with variability in activity and movement performance across patients. Topic models have been used to discover characteristic activity routine patterns of healthy individuals using activity primitives recognized from supervised sensor data. Yet, the applicability of topic models for hemiparetic rehabilitation patients and techniques to derive activity primitives without supervision needs to be addressed. We investigate, 1) whether a topic model-based activity routine discovery framework can infer activity routines of rehabilitation patients from wearable motion sensor data. 2) We compare the performance of our topic model-based activity routine discovery using rule-based and clustering-based activity vocabulary. We analyze the activity routine discovery in a dataset recorded with 11 hemiparetic rehabilitation patients during up to ten full recording days per individual in an ambulatory daycare rehabilitation center using wearable motion sensors attached to both wrists and the non-affected thigh. We introduce and compare rule-based and clustering-based activity vocabulary to process statistical and frequency acceleration features to activity words. Activity words were used for activity routine pattern discovery using topic models based on Latent Dirichlet Allocation. Discovered activity routine patterns were then mapped to six categorized activity routines. Using the rule-based approach, activity routines could be discovered with an average accuracy of 76% across all patients. The rule-based approach outperformed clustering by 10% and showed less confusions for predicted activity routines. Topic models are suitable to discover daily life activity routines in hemiparetic rehabilitation patients without trained classifiers and activity annotations. Activity routines show characteristic patterns regarding activity primitives including body and extremity postures and movement. A patient-independent rule set can be derived. Including expert knowledge supports successful activity routine discovery over completely data-driven clustering.
Gordon, John D.; Latysh, Natalie E.; Lindholm, Sandy J.
2003-01-01
Five external quality-assurance programs were operated by the U.S. Geological Survey for the National Atmospheric Deposition Program/ National Trends Network (NADP/NTN) during 1997 through 1999: the intersite-comparison program, the blind-audit program, the field- audit program, the interlaboratory-comparison program, and the collocated-sampler program. The intersite-comparison program assesses the accuracy of pH and specific-conductance determinations made by NADP/NTN site operators. In two 1997 intersite-comparison studies, 83.7 and 85.8 percent of the pH determinations met the NADP/NTN accuracy goals, whereas 97.3 and 92.4 percent of the specific-conductance determinations met the NADP/NTN accuracy goals. The percentage of pH and specific-conductance determinations that met the accuracy goals in 1998 were, for the most part, higher than in 1997. In two 1998 studies, 90.9 and 90.3 percent of the pH determinations met the accuracy goals compared to 94.7 and 96.0 percent of the specific- conductance measurements meeting the accuracy goals. In one 1999 intersite-comparison study, 89.5 percent and 99.4 percent of pH and specific- conductance determinations, respectively, met the NADP/NTN accuracy goals. The blind-audit program evaluates the effects of routine sample handling, processing, and shipping on the analytical bias and precision of weekly precipitation samples. A portion of the blind-audit sample subject to the normal onsite handling and processing of a weekly precipitation sample is referred to as the bucket portion, whereas the portion receiving only minimal handling is referred to as the bottle portion. Positive bias in regard to blind-audit results indicates that the bucket portion has a higher concentration than the bottle portion. The paired t-test for the 1997 through 1999 blind- audit data indicates that routine sample handling, processing, and shipping introduced a positive bias (a=0.05) for calcium and chloride and a negative bias (cz=0.05) for hydrogen ion. During 1997 through 1999, the median paired differences between the bucket and bottle portions ranged from 0.00 milligram per liter for nitrate and ammonium to +0.010 milligram per liter for both chloride and sulfate. The median paired difference between the bucket and bottle portions for hydrogen ion was -1.086 microequivalents per liter, whereas for specific conductance, the median paired difference between the bucket and bottle portions was -0.200 microsiemen per centimeter during 1997 through 1999. Surface-chemistry effects due to variable amounts of precipitation contacting prewashed sample-collection and shipping-container surfaces were studied in the blind-audit program by using three different sample volumes. The sample- collection and shipping containers used for the blind-audit study were obtained from the site operator's supply and could have been used for precipitation samples. Results of a Kruskal-Wallis analysis of variance test of the relation between paired blind-audit sample differences in units of concentration and sample volume were statistically significant for magnesium, chloride, sulfate, and hydrogen ion during 1997 through 1999. Before 1994, at least 5 of the 10 analytes displayed a statistically significant difference between paired blind-audit differences in units of concentration and sample volume, supporting the premise that chemical reactions between the 13-liter bucket shipping container (primarily the butadiene o-ring lid of the shipping container) and the sample, which resulted in an increasing loss of hydrogen ion with increasing volume, have been eliminated by the new l-liter bottle sample- shipping protocol. The field-audit program measures the effects of field exposure, handling, and processing on the chemistry of NADP/NTN precipitation samples. In the field-audit program, the site operator is instructed to process and submit a quality- control sample following a standard 7-day, Tuesday-to-Tuesday sampling period with no
Multitip scanning bio-Kelvin probe
NASA Astrophysics Data System (ADS)
Baikie, I. D.; Smith, P. J. S.; Porterfield, D. M.; Estrup, P. J.
1999-03-01
We have developed a novel multitip scanning Kelvin probe which can measure changes in biological surface potential ΔVs to within 2 mV and, quasisimultaneously monitor displacement to <1 μm. The control and measurement subcomponents are PC based and incorporate a flexible user interface permitting software control of each individual tip, measurement, and scan parameters. We review the mode of operation and design features of the scanning bio-Kelvin probe including tip steering, signal processing, tip calibration, and novel tip tracking/dithering routines. This system uniquely offers both tip-to-sample spacing control (which is essential to avoid spurious changes in ΔVs due to variations in mean spacing) and a dithering routine to maintain tip orientation to the biological specimen, irrespective of the latter's movement. These features permit long term (>48 h) "active" tracking of the displacement and biopotentials developed along and around a plant shoot in response to an environmental stimulus, e.g., differential illumination (phototropism) or changes in orientation (gravitropism).
Meissner, Tobias; Seckinger, Anja; Rème, Thierry; Hielscher, Thomas; Möhler, Thomas; Neben, Kai; Goldschmidt, Hartmut; Klein, Bernard; Hose, Dirk
2011-12-01
Multiple myeloma is an incurable malignant plasma cell disease characterized by survival ranging from several months to more than 15 years. Assessment of risk and underlying molecular heterogeneity can be excellently done by gene expression profiling (GEP), but its way into clinical routine is hampered by the lack of an appropriate reporting tool and the integration with other prognostic factors into a single "meta" risk stratification. The GEP-report (GEP-R) was built as an open-source software developed in R for gene expression reporting in clinical practice using Affymetrix microarrays. GEP-R processes new samples by applying a documentation-by-value strategy to the raw data to be able to assign thresholds and grouping algorithms defined on a reference cohort of 262 patients with multiple myeloma. Furthermore, we integrated expression-based and conventional prognostic factors within one risk stratification (HM-metascore). The GEP-R comprises (i) quality control, (ii) sample identity control, (iii) biologic classification, (iv) risk stratification, and (v) assessment of target genes. The resulting HM-metascore is defined as the sum over the weighted factors gene expression-based risk-assessment (UAMS-, IFM-score), proliferation, International Staging System (ISS) stage, t(4;14), and expression of prognostic target genes (AURKA, IGF1R) for which clinical grade inhibitors exist. The HM-score delineates three significantly different groups of 13.1%, 72.1%, and 14.7% of patients with a 6-year survival rate of 89.3%, 60.6%, and 18.6%, respectively. GEP reporting allows prospective assessment of risk and target gene expression and integration of current prognostic factors in clinical routine, being customizable about novel parameters or other cancer entities. ©2011 AACR.
Romero-Martínez, Ángel; Moya-Albiol, Luís; Vinkhuyzen, Anna A E; Polderman, Tinca J C
2016-12-01
Autistic traits are characterized by social and communication problems, restricted, repetitive and stereotyped patterns of behavior, interests and activities. The relation between autistic traits and personality characteristics is largely unknown. This study focused on the relation between five specific autistic traits measured with the abridged version of the Autism Spectrum Quotient ("social problems," "preference for routine," "attentional switching difficulties," "imagination impairments," "fascination for numbers and patterns") and Experience Seeking (ES) in a general population sample of adults, and subsequently investigated the genetic and environmental etiology between these traits. Self-reported data on autistic traits and ES were collected in a population sample (n = 559) of unrelated individuals, and in a population based family sample of twins and siblings (n = 560). Phenotypic, genetic and environmental associations between traits were examined in a bivariate model, accounting for sex and age differences. Phenotypically, ES correlated significantly with "preference for routine" and "imagination impairments" in both samples but was unrelated to the other autistic traits. Genetic analyses in the family sample revealed that the association between ES and "preference for routine" and "imagination impairments" could largely be explained by a shared genetic factor (89% and 70%, respectively). Our analyses demonstrated at a phenotypic and genetic level an inverse relationship between ES and specific autistic traits in adults. ES is associated with risk taking behavior such as substance abuse, antisocial behavior and financial problems. Future research could investigate whether autistic traits, in particular strong routine preference and impaired imagination skills, serve as protective factors for such risky behaviors. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Gurtler, R. W.; Baghdadi, A.
1977-01-01
A ribbon-to-ribbon process was used for routine growth of samples for analysis and fabrication into solar cells. One lot of solar cells was completely evaluated: ribbon solar cell efficiencies averaged 9.23% with a highest efficiency of 11.7%. Spherical reflectors have demonstrated significant improvements in laser silicon coupling efficiencies. Material analyses were performed including silicon photovoltage and open circuit photovoltage diffusion length measurements, crystal morphology studies, modulus of rupture measurements, and annealing/gettering studies. An initial economic analysis was performed indicating that ribbon-to-ribbon add-on costs of $.10/watt might be expected in the early 1980's.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lord, David L.; Allen, Raymond
Sandia National Laboratories is seeking access to crude oil samples for a research project evaluating crude oil combustion properties in large-scale tests at Sandia National Laboratories in Albuquerque, NM. Samples must be collected from a source location and transported to Albuquerque in a tanker that complies with all applicable regulations for transportation of crude oil over public roadways. Moreover, the samples must not gain or lose any components, to include dissolved gases, from the point of loading through the time of combustion at the Sandia testing facility. In order to achieve this, Sandia designed and is currently procuring a custommore » tanker that utilizes water displacement in order to achieve these performance requirements. The water displacement procedure is modeled after the GPA 2174 standard “Obtaining Liquid Hydrocarbons Samples for Analysis by Gas Chromatography” (GPA 2014) that is used routinely by crude oil analytical laboratories for capturing and testing condensates and “live” crude oils, though it is practiced at the liter scale in most applications. The Sandia testing requires 3,000 gallons of crude. As such, the water displacement method will be upscaled and implemented in a custom tanker. This report describes the loading process for acquiring a ~3,000 gallon crude oil sample from commercial process piping containing single phase liquid crude oil at nominally 50-100 psig. This document contains a general description of the process (Section 2), detailed loading procedure (Section 3) and associated oil testing protocols (Section 4).« less
Application of statistical process control to qualitative molecular diagnostic assays.
O'Brien, Cathal P; Finn, Stephen P
2014-01-01
Modern pathology laboratories and in particular high throughput laboratories such as clinical chemistry have developed a reliable system for statistical process control (SPC). Such a system is absent from the majority of molecular laboratories and where present is confined to quantitative assays. As the inability to apply SPC to an assay is an obvious disadvantage this study aimed to solve this problem by using a frequency estimate coupled with a confidence interval calculation to detect deviations from an expected mutation frequency. The results of this study demonstrate the strengths and weaknesses of this approach and highlight minimum sample number requirements. Notably, assays with low mutation frequencies and detection of small deviations from an expected value require greater sample numbers to mitigate a protracted time to detection. Modeled laboratory data was also used to highlight how this approach might be applied in a routine molecular laboratory. This article is the first to describe the application of SPC to qualitative laboratory data.
Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.
Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan
2017-05-01
Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.
Reducing beam hardening effects and metal artefacts in spectral CT using Medipix3RX
NASA Astrophysics Data System (ADS)
Rajendran, K.; Walsh, M. F.; de Ruiter, N. J. A.; Chernoglazov, A. I.; Panta, R. K.; Butler, A. P. H.; Butler, P. H.; Bell, S. T.; Anderson, N. G.; Woodfield, T. B. F.; Tredinnick, S. J.; Healy, J. L.; Bateman, C. J.; Aamir, R.; Doesburg, R. M. N.; Renaud, P. F.; Gieseg, S. P.; Smithies, D. J.; Mohr, J. L.; Mandalika, V. B. H.; Opie, A. M. T.; Cook, N. J.; Ronaldson, J. P.; Nik, S. J.; Atharifard, A.; Clyne, M.; Bones, P. J.; Bartneck, C.; Grasset, R.; Schleich, N.; Billinghurst, M.
2014-03-01
This paper discusses methods for reducing beam hardening effects and metal artefacts using spectral x-ray information in biomaterial samples. A small-animal spectral scanner was operated in the 15 to 80 keV x-ray energy range for this study. We use the photon-processing features of a CdTe-Medipix3RX ASIC in charge summing mode to reduce beam hardening and associated artefacts. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. The cupping effect and streak artefacts are quantified in the spectral datasets. The results show reduction in beam hardening effects and metal artefacts in the narrow high energy range acquired using the spectroscopic detector. A post-reconstruction comparison between CdTe-Medipix3RX and Si-Medipix3.1 is discussed. The raw data and processed data are made available (http://hdl.handle.net/10092/8851) for testing with other software routines.
Van Puymbroeck, M; Kuilman, M E; Maas, R F; Witkamp, R F; Leyssens, L; Vanderzande, D; Gelan, J; Raus, J
1998-12-01
17 alpha-Boldenone (17 alpha-BOL) and/or 17 beta-boldenone (17 beta-BOL) appear occasionally in fecal matter of cattle. In addition to 17 alpha-BOL, a whole array of boldenone related substances can be found in the same samples. In vitro experiments with microsomal liver preparations and isolated hepatocytes combined with the excretion profiles found in urine and feces samples of in vivo experiments made it possible to identify several metabolites of 17 beta-BOL in 17 beta-BOL positive feces samples. In one animal treated with 17 beta-BOL, no 17 beta-BOL or its metabolites were present before treatment and most of these compounds disappeared gradually in time after the treatment was stopped. It is not clear what the origin is of 17 alpha-BOL and boldenone metabolites in samples screened routinely for the abuse of anabolic steroids and considered to be 'negative' because of the absence of 17 beta-BOL since other workers showed some evidence that 17 alpha-BOL can be of endogenous origin. However, in our hands, most of these 17 alpha-BOL positive samples, obtained during routinely performed screenings of cattle, contained large amounts of delta 4-androstene-3,17-dione (AED), which normally is absent from routinely screened negative samples. Furthermore, AED was absent in all samples obtained from the animals treated with 17 beta-BOL. We have no direct evidence that 17 alpha-BOL or 17 beta-BOL is of endogenous origin.
Petit, Morgane; Mine, Louis; Pascreau, Tiffany; Brouzes, Chantal; Majoux, Sandrine; Borgel, Delphine; Beaudeux, Jean-Louis; Lasne, Dominique; Hennequin, Carole
2017-12-01
Pneumatic tube delivery system (PTS) enables to reduce considerably turnaround times. The aim of the study was to assess the influence of the PTS on the quality of routine biochemical and hematological tests in our laboratory. Blood samples from 6 hospitalized patients and 8 healthy volunteers were analyzed. Blood samples were delivered to the laboratory by a PTS and by a human courier. We performed the following analysis: ionized calcium, sodium, potassium, lactate deshydrogenase (LDH), aspartate aminotransferase (ASAT), arterial blood gas, complete blood count and coagulation test as prothrombin time, activated partial thromboplastin time, factors V and VIII. Results were compared between the both method of transport according to the recommendation of the Société française de biologie clinique and the French committee for accreditation (SH-GTA01, norme NF ISO 5275-6). The hemolysis index of plasma was similar between the groups and no morphological differences were found on blood cells. For three samples, when delivered by PTS, LDH levels (two samples) and neutrophil polynuclear count (one sample) were above the recommended guidelines compared to those delivered by courier. Conversely, LDH levels and FVIII were below in two samples delivered by PTS. LDH levels, PNN count or factor VIII can be affected by PTS without the clinical interpretation being modified. We concluded that the PTS can be used to transport blood samples for routine biochemical and hematological analysis in our hospital.
Capsule- and disk-filter procedure
Skrobialowski, Stanley C.
2016-01-01
Capsule and disk filters are disposable, self-contained units composed of a pleated or woven filter medium encased in a polypropylene or other plastic housing that can be connected inline to a sample-delivery system (such as a submersible or peristaltic pump) that generates sufficient pressure (positive or negative) to force water through the filter. Filter media are available in several pore sizes, but 0.45 µm is the pore size used routinely for most studies at this time. Capsule or disk filters (table 5.2.1.A.1) are required routinely for most studies when filtering samples for trace-element analyses and are recommended when filtering samples for major-ion or other inorganic-constituent analyses.
Developing Corpus-Based Materials to Teach Pragmatic Routines
ERIC Educational Resources Information Center
Bardovi-Harlig, Kathleen; Mossman, Sabrina; Vellenga, Heidi E.
2015-01-01
This article describes how to develop teaching materials for pragmatics based on authentic language by using a spoken corpus. The authors show how to use the corpus in conjunction with textbooks to identify pragmatic routines for speech acts and how to extract appropriate language samples and adapt them for classroom use. They demonstrate how to…
Code of Federal Regulations, 2013 CFR
2013-07-01
... REGULATIONS Revised Total Coliform Rule § 141.857 Routine monitoring requirements for public water systems... systems serving more than 1,000 persons. (2) Following any total coliform-positive sample taken under the... calendar month has been completed, systems must determine whether any coliform treatment technique triggers...
Carvalho, J J; Jerónimo, P C A; Gonçalves, C; Alpendurada, M F
2008-11-01
European Council Directive 98/83/EC on the quality of water intended for human consumption brought a new challenge for water-quality control routine laboratories, mainly on pesticides analysis. Under the guidelines of ISO/IEC 17025:2005, a multiresidue method was developed, validated, implemented in routine, and studied with real samples during a one-year period. The proposed method enables routine laboratories to handle a large number of samples, since 28 pesticides of 14 different chemical groups can be quantitated in a single procedure. The method comprises a solid-phase extraction step and subsequent analysis by liquid chromatography-mass spectrometry (LC-MS-MS). The accuracy was established on the basis of participation in interlaboratory proficiency tests, with encouraging results (majority |z-score| <2), and the precision was consistently analysed over one year. The limits of quantitation (below 0.050 microg L(-1)) are in agreement with the enforced threshold value for pesticides of 0.10 microg L(-1). Overall method performance is suitable for routine use according to accreditation rules, taking into account the data collected over one year.
Maloney, T.J.; Ludtke, A.S.; Krizman, T.L.
1994-01-01
The US. Geological Survey operates a quality- assurance program based on the analyses of reference samples for the National Water Quality Laboratory in Arvada, Colorado, and the Quality of Water Service Unit in Ocala, Florida. Reference samples containing selected inorganic, nutrient, and low ionic-strength constituents are prepared and disguised as routine samples. The program goal is to determine precision and bias for as many analytical methods offered by the participating laboratories as possible. The samples typically are submitted at a rate of approximately 5 percent of the annual environmental sample load for each constituent. The samples are distributed to the laboratories throughout the year. Analytical data for these reference samples reflect the quality of environmental sample data produced by the laboratories because the samples are processed in the same manner for all steps from sample login through data release. The results are stored permanently in the National Water Data Storage and Retrieval System. During water year 1991, 86 analytical procedures were evaluated at the National Water Quality Laboratory and 37 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic (major ion and trace metal) constituent data for water year 1991 indicated analytical imprecision in the National Water Quality Laboratory for 5 of 67 analytical procedures: aluminum (whole-water recoverable, atomic emission spectrometric, direct-current plasma); calcium (atomic emission spectrometric, direct); fluoride (ion-exchange chromatographic); iron (whole-water recoverable, atomic absorption spectrometric, direct); and sulfate (ion-exchange chromatographic). The results for 11 of 67 analytical procedures had positive or negative bias during water year 1991. Analytical imprecision was indicated in the determination of two of the five National Water Quality Laboratory nutrient constituents: orthophosphate as phosphorus and phosphorus. A negative or positive bias condition was indicated in three of five nutrient constituents. There was acceptable precision and no indication of bias for the 14 low ionic-strength analytical procedures tested in the National Water Quality Laboratory program and for the 32 inorganic and 5 nutrient analytical procedures tested in the Quality of Water Service Unit during water year 1991.
NASA Technical Reports Server (NTRS)
1984-01-01
The structure of the program, the five priority levels, the drive routines, the stepwise drive plan, the figure routines, meander X and y, the range of measurement table, the optimization of figure drive, the figure drive plan, dialogue routines, stack processing, the drive for the main terminal, the protocol routines, the drive for the microterminal, the drive for the experiment computer, and the main program are discussed.
Investigations at Pinal Creek, Arizona, evaluated routine sampling procedures for determination of aqueous inorganic geochemistry and assessment of contaminant transport by colloidal mobility. Sampling variables included pump type and flow rate, collection under air or nitrogen,...
A Gendered Lifestyle-Routine Activity Approach to Explaining Stalking Victimization in Canada.
Reyns, Bradford W; Henson, Billy; Fisher, Bonnie S; Fox, Kathleen A; Nobles, Matt R
2016-05-01
Research into stalking victimization has proliferated over the last two decades, but several research questions related to victimization risk remain unanswered. Accordingly, the present study utilized a lifestyle-routine activity theoretical perspective to identify risk factors for victimization. Gender-based theoretical models also were estimated to assess the possible moderating effects of gender on the relationship between lifestyle-routine activity concepts and victimization risk. Based on an analysis of a representative sample of more than 15,000 residents of Canada from the Canadian General Social Survey (GSS), results suggested conditional support for lifestyle-routine activity theory and for the hypothesis that predictors of stalking victimization may be gender based. © The Author(s) 2015.
Mohammed, Mohammed A; Panesar, Jagdeep S; Laney, David B; Wilson, Richard
2013-04-01
The use of statistical process control (SPC) charts in healthcare is increasing. The primary purpose of SPC is to distinguish between common-cause variation which is attributable to the underlying process, and special-cause variation which is extrinsic to the underlying process. This is important because improvement under common-cause variation requires action on the process, whereas special-cause variation merits an investigation to first find the cause. Nonetheless, when dealing with attribute or count data (eg, number of emergency admissions) involving very large sample sizes, traditional SPC charts often produce tight control limits with most of the data points appearing outside the control limits. This can give a false impression of common and special-cause variation, and potentially misguide the user into taking the wrong actions. Given the growing availability of large datasets from routinely collected databases in healthcare, there is a need to present a review of this problem (which arises because traditional attribute charts only consider within-subgroup variation) and its solutions (which consider within and between-subgroup variation), which involve the use of the well-established measurements chart and the more recently developed attribute charts based on Laney's innovative approach. We close by making some suggestions for practice.
Conversion of NIMROD simulation results for graphical analysis using VisIt
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romero-Talamas, C A
Software routines developed to prepare NIMROD [C. R. Sovinec et al., J. Comp. Phys. 195, 355 (2004)] results for three-dimensional visualization from simulations of the Sustained Spheromak Physics Experiment (SSPX ) [E. B. Hooper et al., Nucl. Fusion 39, 863 (1999)] are presented here. The visualization is done by first converting the NIMROD output to a format known as legacy VTK and then loading it to VisIt, a graphical analysis tool that includes three-dimensional rendering and various mathematical operations for large data sets. Sample images obtained from the processing of NIMROD data with VisIt are included.
Escherichia coli Concentrations in the Mill Creek Watershed, Cleveland, Ohio, 2001-2004
Brady, Amie M.G.
2007-01-01
Mill Creek in Cleveland, Ohio, receives discharges from combined-sewer overflows (CSOs) and other sanitary-sewage inputs. These discharges affect the water quality of the creek and that of its receiving stream, the Cuyahoga River. In an effort to mitigate this problem, the Northeast Ohio Regional Sewer District implemented a project to eliminate or control (by reducing the number of overflows) all of the CSOs in the Mill Creek watershed. This study focused on monitoring the microbiological water quality of the creek before and during sewage-collection system modifications. Routine samples were collected semimonthly from August 2001 through September 2004 at a site near a U.S. Geological Survey stream gage near the mouth of Mill Creek. In addition, event samples were collected September 19 and 22, 2003, when rainfall accumulations were 0.5 inches (in.) or greater. Concentrations of Escherichia coli (E. coli) were determined and instantaneous discharges were calculated. Streamflow and water-quality characteristics were measured at the time of sampling, and precipitation data measured at a nearby precipitation gage were obtained from the National Oceanic and Atmospheric Administration. Concentrations of E. coli were greater than Ohio's single-sample maximum for primary-contact recreation (298 colony-forming units per 100 milliliters (CFU/100 mL)) in 84 percent of the routine samples collected. In all but one routine sample E. coli concentrations in samples collected when instantaneous streamflows were greater than 20 cubic feet per second (ft3/s) were greater than Ohio's single-sample maximum. When precipitation occurred in the 24-hour period before routine sample collection, concentrations were greater than the maximum in 89 percent of the samples as compared to 73 percent when rainfall was absent during the 24 hours prior to routine sample collection. Before modifications to the sewage-collection system in the watershed began, E. coli concentrations in Mill Creek ranged from 220 to 29,000 CFU/100 mL. After major modifications, E. coli concentrations ranged from 110 to 80,000 CFU/100 mL. The percentage of sample E. coli concentrations in the former group greater than Ohio's single-sample maximum was 88 percent, whereas 85 percent of sample concentrations was greater than the maximum after major modifications occurred. Instantaneous discharges of E. coli were calculated for each of the modification periods. No statistically significant difference was observed between the median instantaneous discharges of E. coli for the premodification and minor-modification periods (5.1 ? 106 and 3.6 ? 106 CFU per second, respectively). During rainfall events in September 2003, samples were collected every 15 to 30 minutes. E. coli concentrations in all of these samples (n = 34) were greater than Ohio's single-sample maximum for primary-contact recreation. On September 19, total accumulated rainfall was 1.7 in., and streamflow reached a peak of 1,040 ft3/s. Sample collection started after 0.8 in. of precipitation had fallen and continued throughout the remainder of the storm. For these samples, E. coli concentrations ranged from 32,000 to 140,000 CFU/100 mL. On September 22, total accumulated rainfall was 0.5 in., and streamflow reached a peak of 497 ft3/s. Sample collection began before the start of the rain and continued throughout the storm. E. coli concentrations ranged from 450 to 260,000 CFU/100 mL.
Wang, Ling-jia; Kissler, Hermann J; Wang, Xiaojun; Cochet, Olivia; Krzystyniak, Adam; Misawa, Ryosuke; Golab, Karolina; Tibudan, Martin; Grzanka, Jakub; Savari, Omid; Grose, Randall; Kaufman, Dixon B; Millis, Michael; Witkowski, Piotr
2015-01-01
Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted manually under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely acquired by estimation only. In this study, we validated our digital image analysis (DIA) system developed using the software of Image Pro Plus for islet mass and purity assessment. Application of the DIA allows to better comply with current good manufacturing practice (cGMP) standards. Human islet samples were captured as calibrated digital images for the permanent record. Five trained technicians participated in determination of IEQ and purity by manual counting method and DIA. IEQ count showed statistically significant correlations between the manual method and DIA in all sample comparisons (r >0.819 and p < 0.0001). Statistically significant difference in IEQ between both methods was found only in High purity 100μL sample group (p = 0.029). As far as purity determination, statistically significant differences between manual assessment and DIA measurement was found in High and Low purity 100μL samples (p<0.005), In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between manual counting method and DIA. In conclusion, the DIA used in this study is a reliable technique in determination of IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training and islet information exchange between different islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islets counting and purity estimation. PMID:24806436
ERIC Educational Resources Information Center
Schaaf, Roseann C.; Toth-Cohen, Susan; Johnson, Stephanie L.; Outten, Gina; Benevides, Teal W.
2011-01-01
The purpose of this qualitative study was to explore the lived experience of how sensory-related behaviors of children with autism affected family routines. In-depth semi-structured interviews were conducted with four primary caregivers regarding the meaning and impact of their child's sensory-related behaviors on family routines that occurred…
ERIC Educational Resources Information Center
Kuzle, Ana
2017-01-01
Students regularly struggle with mathematical tasks, particularly those concerning non-routine problems in geometry. Although educators would like for their learners to transfer their knowledge to non-routine and real-life situations, students run into a number of difficulties. The goal of this exploratory study was to analyze three participants'…
Mayberry, Lindsay S.; Shinn, Marybeth; Benton, Jessica Gibbons; Wise, Jasmine
2013-01-01
Maintenance of family processes can protect parents, children, and families from the detrimental effects of extreme stressors, such as homelessness. When families cannot maintain routines and rituals, the stressors of poverty and homelessness can be compounded for both caregivers and children. However, characteristics of living situations common among families experiencing homelessness present barriers to the maintenance of family routines and rituals. We analyzed 80 in-depth interviews with parents who were experiencing or had recently experienced an instance of homelessness. We compared their assessments of challenges to family schedules, routines, and rituals across various living situations, including shelter, transitional housing programs, doubled up (i.e. living temporarily with family/friend), and independent housing. Rules common across shelters and transitional housing programs impeded family processes, and parents felt surveilled and threatened with child protective service involvement in these settings. In doubled up living situations, parents reported adapting their routines to those of the household and having parenting interrupted by opinions of friends and family members. Families used several strategies to maintain family rituals and routines in these living situations and ensure consistency and stability for their children during an otherwise unstable time. PMID:24826832
Mayberry, Lindsay Satterwhite; Shinn, Marybeth; Benton, Jessica Gibbons; Wise, Jasmine
2014-01-01
Maintenance of family processes can protect parents, children, and families from the detrimental effects of extreme stressors, such as homelessness. When families cannot maintain routines and rituals, the stressors of poverty and homelessness can be compounded for both caregivers and children. However, characteristics of living situations common among families experiencing homelessness present barriers to the maintenance of family routines and rituals. We analyzed 80 in-depth interviews with parents who were experiencing or had recently experienced an instance of homelessness. We compared their assessments of challenges to family schedules, routines, and rituals across various living situations, including shelter, transitional housing programs, doubled-up (i.e., living temporarily with family or friends), and independent housing. Rules common across shelters and transitional housing programs impeded family processes, and parents felt surveilled and threatened with child protective service involvement in these settings. In doubled-up living situations, parents reported adapting their routines to those of the household and having parenting interrupted by opinions of friends and family members. Families used several strategies to maintain family routines and rituals in these living situations and ensure consistency and stability for their children during an otherwise unstable time. (c) 2014 APA, all rights reserved.
Eating routines: Embedded, value based, modifiable, and reflective
Jastran, Margaret; Bisogni, Carole A.; Sobal, Jeffery; Blake, Christine; Devine, Carol M.
2009-01-01
Eating routines are a compelling issue because recurring eating behaviors influence nutrition and health. As non-traditional and individualized eating patterns have become more common, new ways of thinking about routine eating practices are needed. This study sought to gain conceptual understanding of working adults' eating routines. Forty-two purposively sampled US adults reported food intake and contextual details about eating episodes in qualitative 24-hour dietary recalls conducted over 7 consecutive days. Using the constant comparative method, researchers analyzed interview transcripts for recurrent ways of eating that were either explicitly reported by study participants as “routines” or emergent in the data. Participants' eating routines included repetition in food consumption as well as eating context, and also involved sequences of eating episodes. Eating routines were embedded in daily schedules for work, family, and recreation. Participants maintained purposeful routines that helped balance tension between demands and values, but they modified routines as circumstances changed. Participants monitored and reflected upon their eating practices and tended to assess their practices in light of their personal identities. These findings provide conceptual insights for food choice researchers and present a perspective from which practitioners who work with individuals seeking to adopt healthful eating practices might usefully approach their tasks. PMID:18835305
Interprofessional communication failures in acute care chains: How can we identify the causes?
van Leijen-Zeelenberg, Janneke E; van Raak, Arno J A; Duimel-Peeters, Inge G P; Kroese, Mariëlle E A L; Brink, Peter R G; Vrijhoef, Hubertus J M
2015-01-01
Although communication failures between professionals in acute care delivery occur, explanations for these failures remain unclear. We aim to gain a deeper understanding of interprofessional communication failures by assessing two different explanations for them. A multiple case study containing six cases (i.e. acute care chains) was carried out in which semi-structured interviews, physical artifacts and archival records were used for data collection. Data were entered into matrices and the pattern-matching technique was used to examine the two complementary propositions. Based on the level of standardization and integration present in the acute care chains, the six acute care chains could be divided into two categories of care processes, with the care chains equally distributed among the categories. Failures in communication occurred in both groups. Communication routines were embedded within organizations and descriptions of communication routines in the entire acute care chain could not be found. Based on the results, failures in communication could not exclusively be explained by literature on process typology. Literature on organizational routines was useful to explain the occurrence of communication failures in the acute care chains. Organizational routines can be seen as repetitive action patterns and play an important role in organizations, as most processes are carried out by means of routines. The results of this study imply that it is useful to further explore the role of organizational routines on interprofessional communication in acute care chains to develop a solution for failures in handover practices.
Kauffmann-Lacroix, C; Albouy-Llaty, M; Migeot, V; Contet-Audonneau, N
2011-09-01
The objective of the survey was to describe the practices of clinical laboratories in terms of cultures in medical mycology. We have implemented this project within the members of the French Society for Medical Mycology (SFMM) to evaluate the analytical processes of the mycological examination in our laboratories. This preliminary study would help to suggest the future French guidelines. A questionnaire regarding the processing of mycology analysis was sent to the 227 members of the SFMM in 2009. The data involved 21 types of samples, direct microscopic examination with or without colouring and the reagents, the number of culture media, the types of media (Sabouraud, Sabouraud antibiotic, Sabouraud cycloheximide and chromogenic medium), temperature and duration of the incubation (days) and the existence of a first result before the end of the incubation period. The analytical processes were compared to an accredited laboratory according to EN ISO 15189. A great heterogeneity was observed in the 36 forms from 27 (75%) laboratories belonging to university hospitals among the 38 existing in France. As for deep samples, two microscopic exams were performed, only one was usually done. A more sensitive technique was preferred to the wet-mount for some samples. Routine samples are often inoculated on a chromogenic media. For deep samples two medium are inoculated (chromogenic media, Sabouraud and antibiotics). If the temperature of incubation is unique, 30°C was chosen. A temperature of 37°C was preferred for samples where Candida spp. is selected. When there are two temperatures of incubation, 27°C and 37°C were preferred. Each biologist can compare his proceedings to the other laboratories and to a laboratory already accredited. The question is to find the best strategies for each medical mycology specimen. They will aid the process of accreditation according to EN ISO 15189, which now applies in all laboratories in Europe. Copyright © 2011 Elsevier Masson SAS. All rights reserved.
Routine activities and victimization at school: the significance of gender.
Popp, Ann Marie; Peguero, Anthony A
2011-08-01
Routine activities theory has not fully considered the role of gender in shaping victimization and yet, the research literature clearly demonstrates that gender is associated with an individual's risk of victimization. In addition to the pervasive effect of gender on victimization, gender shapes an individual's daily routines and thus may create a gender-specific relationship with victimization. This article explores the importance of gender in understanding the relationship between student's participation in extracurricular routine activities (e.g., student government, clubs, sports, and etc.) and the risk of victimization. From the Education Longitudinal Study of 2002, a sample of 10th-grade students was drawn for analyses. Hierarchical Generalized Linear Modeling was employed to explore the role of gender in the relationship between extracurricular routine activities and victimization at school. The results reveal that students' gender indeed interacts with several of the extracurricular routine activities creating gender-specific risks of victimization. This article highlights the importance of gender in explaining victimization and suggests researchers should consider how gender may interact with other routine activities and victimization.
Code of Federal Regulations, 2013 CFR
2013-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2012 CFR
2012-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... has an E. coli-positive sample in any monitoring period (routine and repeat samples are used in this... fails to comply with the reporting and recordkeeping requirements of this subpart. (e) It fails to...
7 CFR 94.3 - Analyses performed and locations of laboratories.
Code of Federal Regulations, 2011 CFR
2011-01-01
... applicable plant on the official certificate. (b) Mandatory egg product samples for Salmonella are required... recognized laboratories for analyzing routine egg product samples for Salmonella. (c) Mandatory egg product...
Taiwo, Lydia; Idris, Suleiman; Abubakar, Aisha; Nguku, Patrick; Nsubuga, Peter; Gidado, Saheed; Okeke, Lilian; Emiasegen, Samuel; Waziri, Endie
2017-01-01
Introduction Immunization is one of the most effective interventions to prevent disease and early child death. A substantial number of children worldwide do not complete immunization schedules because neither health services nor conventional communication mechanisms regularly reach their communities. Knowledge and perception of mothers/caregivers regarding VPDs influence demand and utilization of immunization services. We examined the associations between knowledge, perception and information on routine immunization received by mothers/caregivers in Kaduna State. Methods We enrolled 379 eligible caregivers in a community-based cross-sectional study. We sampled respondents using multistage sampling technique. We collected data on socio-demographic characteristics; knowledge and perception on routine immunization using semi-structured interviewer-administered questionnaire. We conducted bivariate analysis and logistic regression using Epi-InfoTM version 7 at 5% level of significance. Results Mean age of respondents was 28.6 years (standard deviation=±6.6 years), 34% completed secondary school, 65% were unemployed, 49% lived in rural settlements. Among respondents' children 53.3% were females and 62.8% fell within 2nd-5th birth order. Only 15.6% of these children were fully immunized. Seventy-five percent of respondent did not obtain information on routine immunization within 12 months prior to the study. About 64% had unsatisfactory knowledge while 55.4% exhibited poor perceptions regarding routine immunization. Commonest source of information was radio (61.61%). On logistic regression educated participants (Adjusted odds ratio (AOR)=1.9, 95% CI: 1.1-3.3), mothers' perception (AOR=2.6, 95% CI: 1.5-4.5) and monogamous family setting (AOR=2.4, 95% CI: 0.2-0.6) were likely to have obtained information on routine immunization. Conclusion There is low access to information, poor maternal knowledge on routine immunization with low vaccination coverage in this community. Efforts should be made by the Governments to scale up sensitization of mothers/caregivers to improve their knowledge on routine immunization through radio jingles. PMID:29187919
Taiwo, Lydia; Idris, Suleiman; Abubakar, Aisha; Nguku, Patrick; Nsubuga, Peter; Gidado, Saheed; Okeke, Lilian; Emiasegen, Samuel; Waziri, Endie
2017-01-01
Immunization is one of the most effective interventions to prevent disease and early child death. A substantial number of children worldwide do not complete immunization schedules because neither health services nor conventional communication mechanisms regularly reach their communities. Knowledge and perception of mothers/caregivers regarding VPDs influence demand and utilization of immunization services. We examined the associations between knowledge, perception and information on routine immunization received by mothers/caregivers in Kaduna State. We enrolled 379 eligible caregivers in a community-based cross-sectional study. We sampled respondents using multistage sampling technique. We collected data on socio-demographic characteristics; knowledge and perception on routine immunization using semi-structured interviewer-administered questionnaire. We conducted bivariate analysis and logistic regression using Epi-InfoTM version 7 at 5% level of significance. Mean age of respondents was 28.6 years (standard deviation=±6.6 years), 34% completed secondary school, 65% were unemployed, 49% lived in rural settlements. Among respondents' children 53.3% were females and 62.8% fell within 2 nd -5 th birth order. Only 15.6% of these children were fully immunized. Seventy-five percent of respondent did not obtain information on routine immunization within 12 months prior to the study. About 64% had unsatisfactory knowledge while 55.4% exhibited poor perceptions regarding routine immunization. Commonest source of information was radio (61.61%). On logistic regression educated participants (Adjusted odds ratio (AOR)=1.9, 95% CI: 1.1-3.3), mothers' perception (AOR=2.6, 95% CI: 1.5-4.5) and monogamous family setting (AOR=2.4, 95% CI: 0.2-0.6) were likely to have obtained information on routine immunization. There is low access to information, poor maternal knowledge on routine immunization with low vaccination coverage in this community. Efforts should be made by the Governments to scale up sensitization of mothers/caregivers to improve their knowledge on routine immunization through radio jingles.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WATER REGULATIONS Revised Total Coliform Rule § 141.856 Routine monitoring requirements for subpart H... coliform-positive sample taken under the provisions of this section, systems must comply with the repeat... coliform treatment technique triggers specified in § 141.859 have been exceeded. If any trigger has been...
Lampati, L; Maggioni, E; Langer, M; Malacarne, P; Mozzo, R; Pesenti, A; Fumagalli, R
2009-10-01
The aim of this study was to investigate the hypothesis that periodical sampling of the tracheo-bronchial tree in the absence of clinical suspicion of pneumonia is useful to identify bacteria responsible for subsequent late ventilator associated pneumonia (VAP). This was a retrospective observational human study carried out in two medical-surgical intensive care units of two different hospitals. From January 1999 to December 2000, 559 patients, who received invasive respiratory support for more than 48 hours, were screened. Tracheal aspiration (TA) was performed once or twice weekly in all mechanically ventilated patients. The microbiological findings from TA surveillance cultures done in the eight days before suspicion of VAP were compared to those isolated from the positive diagnostic samples done for late onset VAP (after more than four days of mechanical ventilation). The sensitivity, specificity, and positive/negative predictive values of the ability of the surveillance sample to anticipate the VAP pathogen were calculated. Among the microorganisms isolated from TA, 68% were retrieved from diagnostic samples. All VAP pathogens previously isolated were from 43% of the TA samples. If TA was collected 2-4 days before the clinical diagnosis of VAP, pathogens were detected in 58% of samples. In contrast, only 27% were collected more than four days earlier (P<0.05). The positive predictive values for Pseudomonas aeruginosa and methicillin resistant Staphylococcus aureus from routine TA samples were 92% and 90%, respectively. The negative predictive values for Pseudomonas aeruginosa and methicillin resistant Staphylococcus aureus from routine TA samples were 75% and 89%, respectively. TA cultures in ventilated patients may help to predict pathogens. Early detection may lead to earlier treatment in long term ventilated patients when VAP is suspected.
Jacobsz, Lourens A; Zemlin, Annalise E; Roos, Mark J; Erasmus, Rajiv T
2011-10-14
Recent publications report that up to 70% of total laboratory errors occur in the pre-analytical phase. Identification of specific problems highlights pre-analytic processes susceptible to errors. The rejection of unsuitable samples can lead to delayed turnaround time and affect patient care. A retrospective audit was conducted investigating the rejection rate of routine blood specimens received at chemistry and haematology laboratories over a 2-week period. The reasons for rejection and potential clinical impact of these rejections were investigated. Thirty patient files were randomly selected and examined to assess the impact of these rejections on clinical care. A total of 32,910 specimens were received during the study period, of which 481 were rejected, giving a rejection rate of 1.46%. The main reasons for rejection were inappropriate clotting (30%) and inadequate sample volume (22%). Only 51.7% of rejected samples were repeated and the average time for a repeat sample to reach the laboratory was about 5 days (121 h). Of the repeated samples, 5.1% had results within critical values. Examination of patient folders showed that in 40% of cases the rejection of samples had an impact on patient care. The evaluation of pre-analytical processes in the laboratory, with regard to sample rejection, allowed one to identify problem areas where improvement is necessary. Rejected samples due to factors out of the laboratory's control had a definite impact on patient care and can thus affect customer satisfaction. Clinicians should be aware of these factors to prevent such rejections.
Assessment of anaerobic blood cultures in pediatric oncology patients.
Monsonís Cabedo, Manuel; Rives Solá, Susana; Noguera-Julian, Antoni; Urrea Ayala, Mireia; Cruz Martinez, Ofelia; Gené Giralt, Amadeu
2017-01-01
The routine use of a single aerobic bottle for blood culture in pediatric patients has become commonplace, as anaerobic bacteria are not frequently involved in clinically significant infections. The aim of this study was to assess the usefulness of routinely performing anaerobic blood cultures in pediatric oncology patients. Prospective study was conducted on pediatric (<18 years) patients affected with febrile syndrome after receiving chemotherapy for hematological or solid malignancies. Samples were inoculated into pediatric aerobic and standard anaerobic bottles (BacT/Alert automatic system). Strains were considered clinically significant, or deemed as contaminants, depending on isolation circumstances and clinical criteria. A total of 876 blood cultures from 228 patients were processed during the 21-month study period (January 2014 to September 2015). Baseline diagnosis included 143 solid tumors and 67/18 cases of leukemia/lymphoma. Bacterial growth was detected in 90 (10.2%) blood cultures for 95 different isolates, of which 62 (7.1%)/63 isolates were considered clinically significant. Among the latter, 38 (60.3%) microorganisms grew in both aerobic and anaerobic bottles, 18 (28.6%) only in aerobic bottles, and 7 (11.1%) only in anaerobic bottles. Gram-negative bacilli (33; 52.4%), mainly from the Enterobacteriaceae family, were the most frequently isolated microorganisms. Overall, only 3 out of 90 isolates (3.3%) were strict anaerobes (Propionibacterium acnes), and all of them were deemed contaminants. Strict anaerobes did not cause significant infections in febrile pediatric oncology patients, and anaerobic blood culture bottles offered no additional advantages over aerobic media. Our results suggest that routine blood cultures should be solely processed in aerobic media in this group of patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Merriam, Tim; Kaufmann, Rolf; Ebert, Lars; Figi, Renato; Erni, Rolf; Pauer, Robin; Sieberth, Till
2018-06-01
Today, post-mortem computed tomography (CT) is routinely used for forensic identification. Mobile energy-dispersive X-ray fluorescence (EDXRF) spectroscopy of a dentition is a method of identification that has the potential to be easier and cheaper than CT, although it cannot be used with every dentition. In challenging cases, combining both techniques could facilitate the process of identification and prove to be advantageous over chemical analyses. Nine dental restorative material brands were analyzed using EDXRF spectroscopy. Their differentiability was assessed by comparing each material's x-ray fluorescence spectrum and then comparing the spectra to previous research investigating differentiability in CT. To verify EDXRF's precision and accuracy, select dental specimens underwent comparative electron beam excited x-ray spectroscopy (EDS) scans, while the impact of the restorative surface area was studied by scanning a row of dental specimens with varying restorative surface areas (n = 10). EDXRF was able to differentiate all 36 possible pairs of dental filling materials; however, dual-energy CT was only able to differentiate 33 out of 36. The EDS scans showed correlating x-ray fluorescence peaks on the x-ray spectra compared to our EDXRF. In addition, the surface area showed no influence on the differentiability of the dental filling materials. EDXRF has the potential to facilitate corpse identification by differentiating and comparing restorative materials, providing more information compared to post-mortem CT alone. Despite not being able to explicitly identify a brand without a control sample or database, its fast and mobile use could accelerate daily routines or mass victim identification processes. To achieve this goal, further development of EDXRF scanners for this application and further studies evaluating the method within a specific routine need to be performed.
An Easy Method to Eliminate the Effect of Lupus Anticoagulants in the Coagulation Factor Assay.
Tang, Ning; Yin, Shiyu
2016-07-01
To build and evaluate intrinsic coagulation factor assays which can eliminate the effect of lupus anticoagulants (LAC). Commercial silica clotting time confirmatory (SCT-C) reagent containing sufficient synthetic phospholipid and routine activated partial thromboplastin time (APTT) reagent were each used for one-stage detection of FVIII, FIX, and FXI activities, in samples with or without LAC, and the results were compared. For samples without LAC, consistent results of FVIII, FIX, and FXI using both SCT-C reagent and APTT reagent were obtained. For samples with LAC, the assays with SCT-C reagent not only could eliminate the effect of strong lupus anticoagulants but also needed fewer dilutions than that with routine APTT reagent. The intrinsic factor detections by SCT-C reagent are credible and convenient to be used for samples with LAC.
An Excel Workbook for Identifying Redox Processes in Ground Water
Jurgens, Bryant C.; McMahon, Peter B.; Chapelle, Francis H.; Eberts, Sandra M.
2009-01-01
The reduction/oxidation (redox) condition of ground water affects the concentration, transport, and fate of many anthropogenic and natural contaminants. The redox state of a ground-water sample is defined by the dominant type of reduction/oxidation reaction, or redox process, occurring in the sample, as inferred from water-quality data. However, because of the difficulty in defining and applying a systematic redox framework to samples from diverse hydrogeologic settings, many regional water-quality investigations do not attempt to determine the predominant redox process in ground water. Recently, McMahon and Chapelle (2008) devised a redox framework that was applied to a large number of samples from 15 principal aquifer systems in the United States to examine the effect of redox processes on water quality. This framework was expanded by Chapelle and others (in press) to use measured sulfide data to differentiate between iron(III)- and sulfate-reducing conditions. These investigations showed that a systematic approach to characterize redox conditions in ground water could be applied to datasets from diverse hydrogeologic settings using water-quality data routinely collected in regional water-quality investigations. This report describes the Microsoft Excel workbook, RedoxAssignment_McMahon&Chapelle.xls, that assigns the predominant redox process to samples using the framework created by McMahon and Chapelle (2008) and expanded by Chapelle and others (in press). Assignment of redox conditions is based on concentrations of dissolved oxygen (O2), nitrate (NO3-), manganese (Mn2+), iron (Fe2+), sulfate (SO42-), and sulfide (sum of dihydrogen sulfide [aqueous H2S], hydrogen sulfide [HS-], and sulfide [S2-]). The logical arguments for assigning the predominant redox process to each sample are performed by a program written in Microsoft Visual Basic for Applications (VBA). The program is called from buttons on the main worksheet. The number of samples that can be analyzed is only limited by the number of rows in Excel (65,536 for Excel 2003 and XP; and 1,048,576 for Excel 2007), and is therefore appropriate for large datasets.
Jha, Ashish Kumar
2015-01-01
Glomerular filtration rate (GFR) estimation by plasma sampling method is considered as the gold standard. However, this method is not widely used because the complex technique and cumbersome calculations coupled with the lack of availability of user-friendly software. The routinely used Serum Creatinine method (SrCrM) of GFR estimation also requires the use of online calculators which cannot be used without internet access. We have developed user-friendly software "GFR estimation software" which gives the options to estimate GFR by plasma sampling method as well as SrCrM. We have used Microsoft Windows(®) as operating system and Visual Basic 6.0 as the front end and Microsoft Access(®) as database tool to develop this software. We have used Russell's formula for GFR calculation by plasma sampling method. GFR calculations using serum creatinine have been done using MIRD, Cockcroft-Gault method, Schwartz method, and Counahan-Barratt methods. The developed software is performing mathematical calculations correctly and is user-friendly. This software also enables storage and easy retrieval of the raw data, patient's information and calculated GFR for further processing and comparison. This is user-friendly software to calculate the GFR by various plasma sampling method and blood parameter. This software is also a good system for storing the raw and processed data for future analysis.
Schorling, Stefan; Schalasta, Gunnar; Enders, Gisela; Zauke, Michael
2004-01-01
The COBAS AmpliPrep instrument (Roche Diagnostics GmbH, D-68305 Mannheim, Germany) automates the entire sample preparation process of nucleic acid isolation from serum or plasma for polymerase chain reaction analysis. We report the analytical performance of the LightCycler Parvovirus B19 Quantification Kit (Roche Diagnostics) using nucleic acids isolated with the COBAS AmpliPrep instrument. Nucleic acids were extracted using the Total Nucleic Acid Isolation Kit (Roche Diagnostics) and amplified with the LightCycler Parvovirus B19 Quantification Kit. The kit combination processes 72 samples per 8-hour shift. The lower detection limit is 234 IU/ml at a 95% hit-rate, linear range approximately 104-1010 IU/ml, and overall precision 16 to 40%. Relative sensitivity and specificity in routine samples from pregnant women are 100% and 93%, respectively. Identification of a persistent parvovirus B19-infected individual by the polymerase chain reaction among 51 anti-parvovirus B19 IgM-negative samples underlines the importance of additional nucleic acid testing in pregnancy and its superiority to serology in identifying the risk of parvovirus B19 transmission via blood or blood products. Combination of the Total Nucleic Acid Isolation Kit on the COBAS AmpliPrep instrument with the LightCycler Parvovirus B19 Quantification Kit provides a reliable and time-saving tool for sensitive and accurate detection of parvovirus B19 DNA. PMID:14736825
Analytical Results from Routine DSSHT and SEHT Monthly Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
2016-08-17
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal for times when monosodium titanate (MST) is used. Even with nomore » MST strike being performed there exists some small Pu and Sr removal, likely from filtration of fines containing these elements. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 16,400. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior. SRNL recommends that a sample of the strip feed be analyzed for cation and anion content if a further decline in boron concentration is noted in future SEHT samples.« less
Bias Assessment of General Chemistry Analytes using Commutable Samples.
Koerbin, Gus; Tate, Jillian R; Ryan, Julie; Jones, Graham Rd; Sikaris, Ken A; Kanowski, David; Reed, Maxine; Gill, Janice; Koumantakis, George; Yen, Tina; St John, Andrew; Hickman, Peter E; Simpson, Aaron; Graham, Peter
2014-11-01
Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.
Pikkemaat, M G; Rapallini, M L B A; Karp, M T; Elferink, J W A
2010-08-01
Tetracyclines are extensively used in veterinary medicine. For the detection of tetracycline residues in animal products, a broad array of methods is available. Luminescent bacterial biosensors represent an attractive inexpensive, simple and fast method for screening large numbers of samples. A previously developed cell-biosensor method was subjected to an evaluation study using over 300 routine poultry samples and the results were compared with a microbial inhibition test. The cell-biosensor assay yielded many more suspect samples, 10.2% versus 2% with the inhibition test, which all could be confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Only one sample contained a concentration above the maximum residue limit (MRL) of 100 microg kg(-1), while residue levels in most of the suspect samples were very low (<10 microg kg(-1)). The method appeared to be specific and robust. Using an experimental set-up comprising the analysis of a series of three sample dilutions allowed an appropriate cut-off for confirmatory analysis, limiting the number of samples and requiring further analysis to a minimum.
Individual values, learning routines and academic procrastination.
Dietz, Franziska; Hofer, Manfred; Fries, Stefan
2007-12-01
Academic procrastination, the tendency to postpone learning activities, is regarded as a consequence of postmodern values that are prominent in post-industrialized societies. When students strive for leisure goals and have no structured routines for academic tasks, delaying strenuous learning activities becomes probable. The model tested in this study posits that postmodern value orientations are positively related to procrastination and to a lack of daily routines concerning the performance of academic activities. In contrast, modern values are negatively related to procrastination and positively to learning routines. Academic procrastination, in-turn, should be associated with the tendency to prefer leisure activities to schoolwork in case of conflicts between these two life domains. Seven hundred and four students from 6th and 8th grade with a mean age of 13.5 years participated in the study. The sample included students from all tracks of the German educational system. Students completed a questionnaire containing two value prototypes as well as scales on learning routines and procrastination. Decisions in motivational conflicts were measured using two vignettes. Results from structural equation modelling supported the proposed model for the whole sample as well as for each school track. A planned course of the day can prevent procrastination and foster decisions for academic tasks in case of conflicts. Students' learning takes place within a societal context and reflects the values held in the respective culture.
Wang, Jing; Wu, Yue; Yao, Zhenwei; Yang, Zhong
2014-12-01
The aim of this study was to explore the value of three-dimensional sampling perfection with application-optimized contrasts using different flip-angle evolutions (3D-SPACE) sequence in assessment of pituitary micro-lesions. Coronal 3D-SPACE as well as routine T1- and dynamic contrast-enhanced (DCE) T1-weighted images of the pituitary gland were acquired in 52 patients (48 women and four men; mean age, 32 years; age range, 17-50 years) with clinically suspected pituitary abnormality at 3.0 T, retrospectively. The interobserver agreement of assessment results was analyzed with K-statistics. Qualitative analyses were compared using Wilcoxon signed-rank test. There was good interobserver agreement of the independent evaluations for 3D-SPACE images (k = 0.892), fair for routine MR images (k = 0.649). At 3.0 T, 3D-SPACE provided significantly better images than routine MR images in terms of the boundary of pituitary gland, definition of pituitary lesions, and overall image quality. The evaluation of pituitary micro-lesions using combined routine and 3D-SPACE MR imaging was superior to that using only routine or 3D-SPACE imaging. The 3D-SPACE sequence can be used for appropriate and successful evaluation of the pituitary gland. We suggest 3D-SPACE sequence to be a powerful supplemental sequence in MR examinations with suspected pituitary micro-lesions.
Stolker, Alida A. M.; Peters, Ruud J. B.; Zuiderent, Richard; DiBussolo, Joseph M.
2010-01-01
There is an increasing interest in screening methods for quick and sensitive analysis of various classes of veterinary drugs with limited sample pre-treatment. Turbulent flow chromatography in combination with tandem mass spectrometry has been applied for the first time as an efficient screening method in routine analysis of milk samples. Eight veterinary drugs, belonging to seven different classes were selected for this study. After developing and optimising the method, parameters such as linearity, repeatability, matrix effects and carry-over were studied. The screening method was then tested in the routine analysis of 12 raw milk samples. Even without internal standards, the linearity of the method was found to be good in the concentration range of 50 to 500 µg/L. Regarding repeatability, RSDs below 12% were obtained for all analytes, with only a few exceptions. The limits of detection were between 0.1 and 5.2 µg/L, far below the maximum residue levels for milk set by the EU regulations. While matrix effects—ion suppression or enhancement—are obtained for all the analytes the method has proved to be useful for screening purposes because of its sensitivity, linearity and repeatability. Furthermore, when performing the routine analysis of the raw milk samples, no false positive or negative results were obtained. PMID:20379812
Manor, Y.; Handsher, R.; Halmut, T.; Neuman, M.; Bobrov, A.; Rudich, H.; Vonsover, A.; Shulman, L.; Kew, O.; Mendelson, E.
1999-01-01
The global eradication of poliomyelitis, believed to be achievable around the year 2000, relies on strategies which include high routine immunization coverage and mass vaccination campaigns, along with continuous monitoring of wild-type virus circulation by using the laboratory-based acute flaccid paralysis (AFP) surveillance. Israel and the Palestinian Authority are located in a geographical region in which poliovirus is still endemic but have been free of poliomyelitis since 1988 as a result of intensive immunization programs and mass vaccination campaigns. To monitor the wild-type virus circulation, environmental surveillance of sewage samples collected monthly from 25 to 30 sites across the country was implemented in 1989 and AFP surveillance began in 1994. The sewage samples were processed in the laboratory with a double-selective tissue culture system, which enabled economical processing of large number of samples. Between 1989 and 1997, 2,294 samples were processed, and wild-type poliovirus was isolated from 17 of them in four clusters, termed “silent outbreaks,” in September 1990 (type 3), between May and September 1991 (type 1), between October 1994 and June 1995 (type 1), and in December 1996 (type 1). Fifteen of the 17 positive samples were collected in the Gaza Strip, 1 was collected in the West Bank, and 1 was collected in the Israeli city of Ashdod, located close to the Gaza Strip. The AFP surveillance system failed to detect the circulating wild-type viruses. These findings further emphasize the important role that environmental surveillance can play in monitoring the eradication of polioviruses. PMID:10325305
Latysh, Natalie E.; Wetherbee, Gregory A.
2005-01-01
The U.S. Geological Survey, Branch of Quality Systems, operates the external quality-assurance programs for the National Atmospheric Deposition Program/National Trends Network (NADP/NTN). Beginning in 1978, six different programs have been implemented?the intersite-comparison program, the blind-audit program, the sample-handling evaluation program, the field-audit program, the interlaboratory-comparison program, and the collocated-sampler program. Each program was designed to measure error contributed by specific components in the data-collection process. The intersite-comparison program, which was discontinued in 2004, was designed to assess the accuracy and reliability of field pH and specific-conductance measurements made by site operators. The blind-audit and sample-handling evaluation programs, which also were discontinued in 2002 and 2004, respectively, assessed contamination that may result from sampling equipment and routine handling and processing of the wet-deposition samples. The field-audit program assesses the effects of sample handling, processing, and field exposure. The interlaboratory-comparison program evaluates bias and precision of analytical results produced by the contract laboratory for NADP, the Illinois State Water Survey, Central Analytical Laboratory, and compares its performance with the performance of international laboratories. The collocated-sampler program assesses the overall precision of wet-deposition data collected by NADP/NTN. This report documents historical operations and the operating procedures for each of these external quality-assurance programs. USGS quality-assurance information allows NADP/NTN data users to discern between actual environmental trends and inherent measurement variability.
Vogeser, Michael; Spöhrer, Ute
2006-01-01
Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.
Analysis of routine pilot-controller communication
NASA Technical Reports Server (NTRS)
Morrow, Daniel G.; Lee, Alfred; Rodvold, Michelle
1990-01-01
Although pilot-controller communication is central to aviation safety, this area of aviation human factors has not been extensively researched. Most research has focused on what kinds of communication problems occur. A more complete picture of communication problems requires understanding how communication usually works in routine operations. A sample of routine pilot-controller communication in the TRACON environment is described. After describing several dimensions of routine communication, three kinds of communication problems are treated: inaccuracies such as incorrect readbacks, procedural deviations such as missing callsigns and readbacks, and nonroutine transactions where pilot and controller must deal with misunderstandings or other communication problems. Preliminary results suggest these problems are not frequent events in daily operations. However, analysis of the problems that do occur suggest some factors that may cause them.
Hutchison, M L; Taylor, M J; Tchòrzewska, M A; Ford, G; Madden, R H; Knowles, T G
2017-05-01
To identify production and processing practices that might reduce Campylobacter numbers contaminating chicken broiler carcasses. The numbers of campylobacters were determined on carcass neck skins after processing or in broiler house litter samples. Supplementary information that described farm layouts, farming conditions for individual flocks, the slaughterhouse layouts and operating conditions inside plants was collected, matched with each Campylobacter test result. Statistical models predicting the numbers of campylobacters on neck skins and in litter were constructed. Carcass microbial contamination was more strongly influenced by on-farm production practices compared with slaughterhouse activities. We observed correlations between the chilling, washing and defeathering stages of processing and the numbers of campylobacters on carcasses. There were factors on farm that also correlated with numbers of campylobacters in litter. These included bird gender, the exclusion of dogs from houses, beetle presence in the house litter and the materials used to construct the house frame. Changes in farming practices have greater potential for reducing chicken carcass microbial contamination compared with processing interventions. Routine commercial practices were identified that were correlated with lowered numbers of campylobacters. Consequently, these practices are likely to be both cost-effective and suitable for adoption into established farms and commercial processing. © 2017 The Authors. Journal of Applied Microbiology published by John Wiley & Sons Ltd on behalf of Society for Applied Microbiology.
Blanchard, P C
2006-01-01
The air transportation of infectious materials is regulated by international air transport associations and based on United Nations Model regulations which have become more practical in addressing animal disease agents. However, individual countries' import and interstate requirements determine what materials can be imported and transported, and this approval process can be long, resulting in delays in organism confirmation, use of international OIE and other reference laboratories, and acquisition of reference materials, proficiency test panels, and reagents for performing necessary testing. Delays can be prevented for permits that are required for the routine work performed by a laboratory through the use of comprehensive and annually renewed permits. This process, however, does not address new and exotic agents where time is critical to an effective emergency response. This paper suggests actions by both the OIE and regulatory authorities which can assist in streamlining and expediting the permit process.
Antigen Masking During Fixation and Embedding, Dissected
Scalia, Carla Rossana; Boi, Giovanna; Bolognesi, Maddalena Maria; Riva, Lorella; Manzoni, Marco; DeSmedt, Linde; Bosisio, Francesca Maria; Ronchi, Susanna; Leone, Biagio Eugenio; Cattoretti, Giorgio
2016-01-01
Antigen masking in routinely processed tissue is a poorly understood process caused by multiple factors. We sought to dissect the effect on antigenicity of each step of processing by using frozen sections as proxies of the whole tissue. An equivalent extent of antigen masking occurs across variable fixation times at room temperature. Most antigens benefit from longer fixation times (>24 hr) for optimal detection after antigen retrieval (AR; for example, Ki-67, bcl-2, ER). The transfer to a graded alcohol series results in an enhanced staining effect, reproduced by treating the sections with detergents, possibly because of a better access of the polymeric immunohistochemical detection system to tissue structures. A second round of masking occurs upon entering the clearing agent, mostly at the paraffin embedding step. This may depend on the non-freezable water removal. AR fully reverses the masking due both to the fixation time and the paraffin embedding. AR itself destroys some epitopes which do not survive routine processing. Processed frozen sections are a tool to investigate fixation and processing requirements for antigens in routine specimens. PMID:27798289
Solubility testing of actinides on breathing-zone and area air samples
NASA Astrophysics Data System (ADS)
Metzger, Robert Lawrence
The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine plant operations. The solubility profiles developed from this work showed excellent agreement with the results of the worker urine bioassay program at the plant and identified a significant error in existing internal dose assessments at this facility.
Pratumvinit, Busadee; Reesukumal, Kanit; Wongkrajang, Preechaya; Khejonnit, Varanya; Klinbua, Cherdsak; Dangneawnoi, Weerapol
2013-11-15
Acidification of urine has been recommended before testing for calcium, phosphate, and magnesium. We investigated the necessity of pre-analytical acidification in both crystallized and non-crystallized urine samples. From 130 urine samples obtained via routine urine analysis, 65 (50%) samples were classified as non-crystallized. All samples were divided into three groups: untreated samples, acidified samples with HCl, and acidified samples after 1h room-temperature incubation. Urine samples were measured for calcium, phosphate, magnesium, and creatinine using Modular P800 and were examined for crystals using light microscopy. In crystallized samples, acidified samples with 1h incubation had significantly higher Ca/Cr, P/Cr, and Mg/Cr than did untreated samples with mean differences of 0.04, 0.03, and 0.01 mg/mg, respectively (P<0.001). In acidified samples that were analyzed immediately, crystallized samples had lower calcium concentrations than those of acidified samples with 1h incubation and a mean difference of 0.21 mg/dl (P = 0.025). None of the sample differences which exceeded the critical difference of urinary Ca, P and Mg was observed. Acidification of urine should be performed before the measurement of Ca, P, and Mg in the presence of urinary crystals. However, the lack of an acidification process does not result in a clinically significant change. © 2013.
[Assessing program sustainability in public health organizations: a tool-kit application in Haiti].
Ridde, V; Pluye, P; Queuille, L
2006-10-01
Public health stakeholders are concerned about program sustainability. However, they usually conceive sustainability in accordance with financial criteria for at least one reason. No simple frameworks are operationally and theoretically sound enough to globally evaluate program sustainability. The present paper aims to describe an application of one framework assessment tool used to evaluate the sustainability level and process of a Nutritional Care Unit managed by a Swiss humanitarian agency to fight against severe child malnutrition in a Haitian area. The managing agency is committed to put this Unit back into the structure of a local public hospital. The evaluation was performed within the sustainability framework proposed in a former article. Data were collected with a combination of tools, semi-structured interviews (n=33, medical and support staff from the agency and the hospital), participatory observation and document review. Data concerned the four characteristics of organizational routines (memory, adaptation, values and rules) enabling assess to the level of sustainability. In addition, data were related to three types of events distinguishing routinization processes from implementation processes: specific events of routinization, routinization-implementation joint events, and specific events of implementation. Data analysis was thematic and results were validated by actors through a feed-back session and written comments. The current level of sustainability of the Nutritional Care Unit within the Hospital is weak: weak memory, high adaptation, weak sharing of values and rules. This may be explained by the sustainability process, and the absence of specific routinization events. The relevance of such processes is reasonable, while it has been strongly challenged in the troublesome Haitian context. Riots have been widespread over the last years, creating difficulties for the Hospital. This experience suggests the proposed framework and sustainability assessment tools are useful when the context permits scrutinization of program sustainability.
Sugano, Mitsutoshi; Shimada, Masashi; Moriyoshi, Miho; Kitagawa, Kiyoki; Nakashima, Hiromi; Wada, Hideo; Yanagihara, Katsunori; Fujisawa, Shinya; Yonekawa, Osamu; Honda, Takayuki
2012-05-01
Routine laboratory data are discussed by time series analysis in reversed clinicopathological conferences (R-CPC) at Shinshu University School of Medicine. We can identify fine changes in the laboratory data and the importance of negative data (without any changes) using time series analysis. Routine laboratory tests can be performed repeatedly and relatively cheaply, and time series analysis can be performed. The examination process of routine laboratory data in the R-CPC is almost the same as the process of taking physical findings. Firstly, general findings are checked and then the state of each organ is examined. Although routine laboratory data are cheap, we can obtain much more information about a patient's state than from physical examinations. In this R-CPC, several specialists in the various fields of laboratory medicine discussed the routine laboratory data of a patient, and we tried to understand the detailed state of the patient. R-CPC is an educational method to examine laboratory data and we, reconfirmed the usefulness of R-CPC to elucidate the clinical state of the patient.
Quality Improvement Initiative to Improve HPV Vaccine Initiation at Nine Years of Age,.
Goleman, Martha J; Dolce, Millie; Morack, Jennifer
2018-05-26
Adolescent human papillomavirus (HPV) vaccine rates remain low. Early vaccination may improve the efficacy of the vaccine and immunization rates. However, clinicians have not routinely made a strong recommendation to younger adolescents. This study assessed the feasibility of routine vaccination at nine years of age. Three sequential quality improvement (QI) interventions were implemented to shift the initiation of the HPV vaccine to nine years of age in a primary care network in low-income neighborhoods in Columbus, Ohio. The first intervention changed the electronic medical record (EMR) alert for the HPV vaccine from eleven to nine years of age and focused on cancer prevention when discussing the vaccine with families. The second intervention was formation of an HPV QI team. The third intervention was a clinic incentive for HPV captured opportunity rates. Immunization rates were monitored using statistical process control charts to compare the HPV immunization rate in a sample of nine and ten-year-old children with a sample of 11 and 12-year-old children. The percentage of patients receiving an HPV vaccine before 11 years increased from 4.6% to 35.7% during the six months after the QI initiative began and to 60.8% 18 months after the project began. In comparison, the HPV vaccination rate in the sample of 11 and 12 year-olds increased from 78.7% to 82.8% 18 months later. This QI project used multiple interventions to increase HPV vaccination at nine years of age in a large primary care network serving a diverse low-income population. Copyright © 2018. Published by Elsevier Inc.
ERIC Educational Resources Information Center
McLoyd, Vonnie C.; Toyokawa, Teru; Kaplan, Rachel
2008-01-01
Using data from a sample of 455 African American children (ages 10 to 12 years) and their parents, this study tests a hypothesized model linking (a) maternal work demands to family routines through work-family conflict and depressive symptoms and (b) maternal work demands to children's externalizing and internalizing problems through family…
ERIC Educational Resources Information Center
Spano, Richard; Nagy, Steve
2005-01-01
Although the overall crime rate dropped between 1993 and 2000, both adolescent violence and violent crime in rural areas has been on the rise. However, little research has been conducted on the determinants of rural violence using targeted regional samples of rural youth. This study examines the applicability of lifestyle/routine activities (RA)…
Pitfalls in lung cancer molecular pathology: how to limit them in routine practice?
Ilie, M; Hofman, P
2012-01-01
New treatment options in advanced non-small cell lung carcinoma (NSCLC) targeting activating epidermal growth factor receptor (EGFR) gene mutations and other genetic alterations demonstrated the clinical significance of the molecular features of specific subsets of tumors. Therefore, the development of personalized medicine has stimulated the routine integration into pathology departments of somatic mutation testing. However, clinical mutation testing must be optimized and standardized with regard to histological profile, type of samples, pre-analytical steps, methodology and result reporting. Routine molecular testing in NSCLC is currently moving beyond EGFR mutational analysis. Recent progress of targeted therapies will require molecular testing for a wide panel of mutations for a personalized molecular diagnosis. As a consequence, efficient testing of multiple molecular abnormalities is an urgent requirement in thoracic oncology. Moreover, increasingly limited tumor sample becomes a major challenge for molecular pathology. Continuous efforts should be made for safe, effective and specific molecular analyses. This must be based on close collaboration between the departments involved in the management of lung cancer. In this review we explored the practical issues and pitfalls surrounding the routine implementation of molecular testing in NSCLC in a pathology laboratory.
Jaureguiberry, María; Madoz, Laura Vanina; Giuliodori, Mauricio Javier; Wagener, Karen; Prunner, Isabella; Grunert, Tom; Ehling-Schulz, Monika; Drillich, Marc; de la Sota, Rodolfo Luzbel
2016-11-28
Uterine disorders are common postpartum diseases in dairy cows. In practice, uterine treatment is often based on systemic or locally applied antimicrobials with no previous identification of pathogens. Accurate on-farm diagnostics are not available, and routine testing is time-consuming and cost intensive. An accurate method that could simplify the identification of uterine pathogenic bacteria and improve pathogen-specific treatments could be an important advance to practitioners. The objective of the present study was to evaluate whether a database built with uterine bacteria from European dairy cows could be used to identify bacteria from Argentinean cows by Fourier transformed infrared (FTIR) spectroscopy. Uterine samples from 64 multiparous dairy cows with different types of vaginal discharge (VD) were collected between 5 and 60 days postpartum, analyzed by routine bacteriological testing methods and then re-evaluated by FTIR spectroscopy (n = 27). FTIR spectroscopy identified Escherichia coli in 12 out of 14 samples and Trueperella pyogenes in 8 out of 10 samples. The agreement between the two methods was good with a Kappa coefficient of 0.73. In addition, the likelihood for bacterial growth of common uterine pathogens such as E. coli and T. pyogenes tended to increase with VD score. The odds for a positive result to E. coli or T. pyogenes was 1.88 times higher in cows with fetid VD than in herdmates with clear normal VD. We conclude that the presence of E. coli and T. pyogenes in uterine samples from Argentinean dairy cows can be detected with FTIR with the use of a database built with uterine bacteria from European dairy cows. Future studies are needed to determine if FTIR can be used as an alternative to routine bacteriological testing methods.
[Optimized application of nested PCR method for detection of malaria].
Yao-Guang, Z; Li, J; Zhen-Yu, W; Li, C
2017-04-28
Objective To optimize the application of the nested PCR method for the detection of malaria according to the working practice, so as to improve the efficiency of malaria detection. Methods Premixing solution of PCR, internal primers for further amplification and new designed primers that aimed at two Plasmodium ovale subspecies were employed to optimize the reaction system, reaction condition and specific primers of P . ovale on basis of routine nested PCR. Then the specificity and the sensitivity of the optimized method were analyzed. The positive blood samples and examination samples of malaria were detected by the routine nested PCR and the optimized method simultaneously, and the detection results were compared and analyzed. Results The optimized method showed good specificity, and its sensitivity could reach the pg to fg level. The two methods were used to detect the same positive malarial blood samples simultaneously, the results indicated that the PCR products of the two methods had no significant difference, but the non-specific amplification reduced obviously and the detection rates of P . ovale subspecies improved, as well as the total specificity also increased through the use of the optimized method. The actual detection results of 111 cases of malarial blood samples showed that the sensitivity and specificity of the routine nested PCR were 94.57% and 86.96%, respectively, and those of the optimized method were both 93.48%, and there was no statistically significant difference between the two methods in the sensitivity ( P > 0.05), but there was a statistically significant difference between the two methods in the specificity ( P < 0.05). Conclusion The optimized PCR can improve the specificity without reducing the sensitivity on the basis of the routine nested PCR, it also can save the cost and increase the efficiency of malaria detection as less experiment links.
Previously unknown species of Aspergillus.
Gautier, M; Normand, A-C; Ranque, S
2016-08-01
The use of multi-locus DNA sequence analysis has led to the description of previously unknown 'cryptic' Aspergillus species, whereas classical morphology-based identification of Aspergillus remains limited to the section or species-complex level. The current literature highlights two main features concerning these 'cryptic' Aspergillus species. First, the prevalence of such species in clinical samples is relatively high compared with emergent filamentous fungal taxa such as Mucorales, Scedosporium or Fusarium. Second, it is clearly important to identify these species in the clinical laboratory because of the high frequency of antifungal drug-resistant isolates of such Aspergillus species. Matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently been shown to enable the identification of filamentous fungi with an accuracy similar to that of DNA sequence-based methods. As MALDI-TOF MS is well suited to the routine clinical laboratory workflow, it facilitates the identification of these 'cryptic' Aspergillus species at the routine mycology bench. The rapid establishment of enhanced filamentous fungi identification facilities will lead to a better understanding of the epidemiology and clinical importance of these emerging Aspergillus species. Based on routine MALDI-TOF MS-based identification results, we provide original insights into the key interpretation issues of a positive Aspergillus culture from a clinical sample. Which ubiquitous species that are frequently isolated from air samples are rarely involved in human invasive disease? Can both the species and the type of biological sample indicate Aspergillus carriage, colonization or infection in a patient? Highly accurate routine filamentous fungi identification is central to enhance the understanding of these previously unknown Aspergillus species, with a vital impact on further improved patient care. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Zhang, Y.-S.; Collins, A.L.; Horowitz, A.J.
2012-01-01
Reliable information on catchment scale suspended sediment sources is required to inform the design of management strategies for helping abate the numerous environmental issues associated with enhanced sediment mobilization and off-site loadings. Since sediment fingerprinting techniques avoid many of the logistical constraints associated with using more traditional indirect measurement methods at catchment scale, such approaches have been increasingly reported in the international literature and typically use data sets collected specifically for sediment source apportionment purposes. There remains scope for investigating the potential for using geochemical data sets assembled by routine monitoring programmes to fingerprint sediment provenance. In the United States, routine water quality samples are collected as part of the US Geological Survey's revised National Stream Quality Accounting Network programme. Accordingly, the geochemistry data generated from these samples over a 10-year period (1996-2006) were used as the basis for a fingerprinting exercise to assess the key tributary sub-catchment spatial sources of contemporary suspended sediment transported by the Ohio River. Uncertainty associated with the spatial source estimates was quantified using a Monte Carlo approach in conjunction with mass balance modelling. Relative frequency weighted means were used as an alternative way of summarizing the spatial source contributions, thereby avoiding the need to use confidence limits. The results should be interpreted in the context of the routine, but infrequent nature, of the suspended sediment samples used to assemble geochemistry as a basis for the sourcing exercise. Nonetheless, the study demonstrates how routine monitoring samples can be used to provide some preliminary information on sediment provenance in large drainage basins. ?? 2011 John Wiley & Sons, Ltd.
Van Ginderdeuren, Rita; Van Calster, Joachim; Stalmans, Peter; Van den Oord, Joost
2014-08-01
In this prospective study, a universal protocol for sampling and analysing vitreous material was investigated. Vitreous biopsies are difficult to handle because of the paucity of cells and the gelatinous structure of the vitreous. Histopathological analysis of the vitreous is useful in difficult uveitis cases to differentiate uveitis from lymphoma or infection and to define the type of cellular reaction. Hundred consecutive vitreous samples were analysed with the Cellient tissue processor (Hologic). This machine is a fully automated processor starting from a specified container with PreservCyt (fixative fluid) with cells to paraffin. Cytology was compared with fixatives Cytolyt (contains a mucolyticum) and PreservCyt. Routine histochemical and immunostainings were evaluated. In 92% of the cases, sufficient material was found for diagnosis. In 14%, a Cytolyt wash was necessary to prevent clotting of the tubes in the Cellient due to the viscosity of the sample. In 23%, the diagnosis was an acute inflammation (presence of granulocytes); in 33%, chronic active inflammation (presence of T lymphocytes); in 33%, low-grade inflammation (presence of CD68 cells, without T lymphocytes); and in 3%, a malignant process. A standardized protocol for sampling and handling vitreous biopsies, fixing in PreservCyt and processing by the Cellient gives a satisfactory result in morphology, number of cells and possibility of immuno-histochemical stainings. The diagnosis can be established or confirmed in more than 90% of cases. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Monocyte chemotactic protein-3: possible involvement in apical periodontitis chemotaxis.
Dezerega, A; Osorio, C; Mardones, J; Mundi, V; Dutzan, N; Franco, M; Gamonal, J; Oyarzún, A; Overall, C M; Hernández, M
2010-10-01
To study the expression of monocyte chemotactic protein-3 (MCP-3, also known as chemokine CCL-7) in tissue from apical lesions (AL) and to associate MCP-3 expression with symptomatic or asymptomatic apical periodontitis. To determine the expression of MCP-3 in AL, biopsies obtained during tooth extraction procedures were fixed, subjected to routine processing and diagnosed as apical granuloma (AG) (n = 7) or radicular cyst (RC) (n = 5). As controls, apical periodontal ligament (PDL) specimens from healthy premolars extracted for orthodontics reasons were included (n = 7). All specimens were immunostained for MCP-3 and examined under a light microscope. In addition, homogenates from AL (n = 14) and healthy PDL samples (n = 7) were studied through immunowestern blot. Finally, periapical exudates samples were collected from root canals of teeth having diagnosis of symptomatic (n = 14) and asymptomatic apical periodontitis (n = 14) during routine endodontic treatments and analysed by immunowestern blot and densitometry. MCP-3 was detected in AG and RC and localized mainly to inflammatory leucocytes, whereas no expression was observed in healthy PDLs. MCP-3 was also detected in periapical exudate, and its levels were significantly higher in symptomatic than in asymptomatic apical periodontitis. MCP-3 was expressed in AL and its levels associated with clinical symptoms. MCP-3 might play a role in disease pathogenesis, possibly by stimulating mononuclear chemotaxis. © 2010 International Endodontic Journal.
Shakespeare, Judy; Blake, Fiona; Garcia, Jo
2003-01-01
BACKGROUND: Screening for postnatal depression using the Edinburgh Postnatal Depression Scale (EPDS) has been widely recommended and implemented in primary care, although little is known about how acceptable it is to women. AIM: To explore the acceptability to women of postnatal screening by health visitors with the EPDS. DESIGN OF STUDY: Qualitative interview study. SETTING: Postnatal patients from 22 general practices within the area of Oxford City Primary Care Group. METHOD: Thirty-nine postnatal women from a purposive sample were interviewed, chosen on the basis of different general practices, EPDS results at eight weeks and eight months postnatal, and whether 'listening visits' were received. The interviews were analysed using the constant comparative method. RESULTS: Just over half of the women interviewed found screening with the EPDS less than acceptable, whatever their postnatal emotional health. The main themes identified were problems with the process of screening and, in particular, the venue, the personal intrusion of screening and stigma. The women interviewed had a clear preference for talking about how they felt, rather than filling out a questionnaire. CONCLUSION: For this sample, routine screening with the EPDS was less than acceptable for the majority of women. This is of concern, as universal screening with the EPDS for the detection of postnatal depression is already recommended and widespread in primary care. PMID:14601337
Root cause analysis of laboratory turnaround times for patients in the emergency department.
Fernandes, Christopher M B; Worster, Andrew; Hill, Stephen; McCallum, Catherine; Eva, Kevin
2004-03-01
Laboratory investigations are essential to patient care and are conducted routinely in emergency departments (EDs). This study reports the turnaround times at an academic, tertiary care ED, using root cause analysis to identify potential areas of improvement. Our objectives were to compare the laboratory turnaround times with established benchmarks and identify root causes for delays. Turnaround and process event times for a consecutive sample of hemoglobin and potassium measurements were recorded during an 8-day study period using synchronized time stamps. A log transformation (ln [minutes + 1]) was performed to normalize the time data, which were then compared with established benchmarks using one-sample t tests. The turnaround time for hemoglobin was significantly less than the established benchmark (n = 140, t = -5.69, p < 0.001) and that of potassium was significantly greater (n = 121, t = 12.65, p < 0.001). The hemolysis rate was 5.8%, with 0.017% of samples needing recollection. Causes of delays included order-processing time, a high proportion (43%) of tests performed on patients who had been admitted but were still in the ED waiting for a bed, and excessive laboratory process times for potassium. The turnaround time for hemoglobin (18 min) met the established benchmark, but that for potassium (49 min) did not. Root causes for delay were order-processing time, excessive queue and instrument times for potassium and volume of tests for admitted patients. Further study of these identified causes of delays is required to see whether laboratory TATs can be reduced.
The successful incorporation of Ag into single grain, Y-Ba-Cu-O bulk superconductors
NASA Astrophysics Data System (ADS)
Congreve, Jasmin V. J.; Shi, Yunhua; Dennis, Anthony R.; Durrell, John H.; Cardwell, David A.
2018-07-01
The use of RE-Ba-Cu-O [(RE)BCO] bulk superconductors, where RE = Y, Gd, Sm, in practical applications is, at least in part, limited by their mechanical properties and brittle nature, in particular. Alloying these materials with silver, however, produces a significant improvement in strength without any detrimental impact on their superconducting properties. Unfortunately, the top seeded melt growth technique, used routinely to process bulk (RE)BCO superconductors in the form of large, single grains required for practical applications, is complex and has a large number of inter-related variables, so the addition of silver increases the complexity of the growth process even further. This can make successful growth of this system extremely challenging. Here we report measurements of the growth rate of YBCO-Ag fabricated using a new growth technique consisting of continuous cooling and isothermal hold process. The resulting data form the basis of a model that has been used to derive suitable heating profiles for the successful single grain growth of YBCO-Ag bulk superconductors of up to 26 mm in diameter. The microstructure and distribution of silver within these samples have been studied in detail. The maximum trapped field at the top surface of the bulk YBCO-Ag samples has been found to be comparable to that of standard YBCO processed without Ag. The YBCO-Ag samples also exhibit a much more uniform trapped field profile compared to that of YBCO.
A microcontroller-based lock-in amplifier for sub-milliohm resistance measurements.
Bengtsson, Lars E
2012-07-01
This paper presents a novel approach to the design of a digital ohmmeter with a resolution of <60 μΩ based on a general-purpose microcontroller and a high-impedance instrumentation amplifier only. The design uses two digital I/O-pins to alternate the current through the sample resistor and combined with a proper firmware routine, the design is a lock-in detector that discriminates any signal that is out of phase/frequency with the reference signal. This makes it possible to selectively detect the μV drop across sample resistors down to 55.6 μΩ using only the current that can be supplied by the digital output pins of a microcontroller. This is achieved without the need for an external reference signal generator and does not rely on the computing processing power of a digital signal processor.
An invertebrate embryologist's guide to routine processing of confocal images.
von Dassow, George
2014-01-01
It is almost impossible to use a confocal microscope without encountering the need to transform the raw data through image processing. Adherence to a set of straightforward guidelines will help ensure that image manipulations are both credible and repeatable. Meanwhile, attention to optimal data collection parameters will greatly simplify image processing, not only for convenience but for quality and credibility as well. Here I describe how to conduct routine confocal image processing tasks, including creating 3D animations or stereo images, false coloring or merging channels, background suppression, and compressing movie files for display.
Robbe, Pauline; Popitsch, Niko; Knight, Samantha J L; Antoniou, Pavlos; Becq, Jennifer; He, Miao; Kanapin, Alexander; Samsonova, Anastasia; Vavoulis, Dimitrios V; Ross, Mark T; Kingsbury, Zoya; Cabes, Maite; Ramos, Sara D C; Page, Suzanne; Dreau, Helene; Ridout, Kate; Jones, Louise J; Tuff-Lacey, Alice; Henderson, Shirley; Mason, Joanne; Buffa, Francesca M; Verrill, Clare; Maldonado-Perez, David; Roxanis, Ioannis; Collantes, Elena; Browning, Lisa; Dhar, Sunanda; Damato, Stephen; Davies, Susan; Caulfield, Mark; Bentley, David R; Taylor, Jenny C; Turnbull, Clare; Schuh, Anna
2018-02-01
PurposeFresh-frozen (FF) tissue is the optimal source of DNA for whole-genome sequencing (WGS) of cancer patients. However, it is not always available, limiting the widespread application of WGS in clinical practice. We explored the viability of using formalin-fixed, paraffin-embedded (FFPE) tissues, available routinely for cancer patients, as a source of DNA for clinical WGS.MethodsWe conducted a prospective study using DNAs from matched FF, FFPE, and peripheral blood germ-line specimens collected from 52 cancer patients (156 samples) following routine diagnostic protocols. We compared somatic variants detected in FFPE and matching FF samples.ResultsWe found the single-nucleotide variant agreement reached 71% across the genome and somatic copy-number alterations (CNAs) detection from FFPE samples was suboptimal (0.44 median correlation with FF) due to nonuniform coverage. CNA detection was improved significantly with lower reverse crosslinking temperature in FFPE DNA extraction (80 °C or 65 °C depending on the methods). Our final data showed somatic variant detection from FFPE for clinical decision making is possible. We detected 98% of clinically actionable variants (including 30/31 CNAs).ConclusionWe present the first prospective WGS study of cancer patients using FFPE specimens collected in a routine clinical environment proving WGS can be applied in the clinic.GENETICS in MEDICINE advance online publication, 1 February 2018; doi:10.1038/gim.2017.241.
Verbal Processing Speed and Executive Functioning in Long-Term Cochlear Implant Users
Pisoni, David B.; Kronenberger, William G.
2015-01-01
Purpose The purpose of this study was to report how verbal rehearsal speed (VRS), a form of covert speech used to maintain verbal information in working memory, and another verbal processing speed measure, perceptual encoding speed, are related to 3 domains of executive function (EF) at risk in cochlear implant (CI) users: verbal working memory, fluency-speed, and inhibition-concentration. Method EF, speech perception, and language outcome measures were obtained from 55 prelingually deaf, long-term CI users and matched controls with normal hearing (NH controls). Correlational analyses were used to assess relations between VRS (articulation rate), perceptual encoding speed (digit and color naming), and the outcomes in each sample. Results CI users displayed slower verbal processing speeds than NH controls. Verbal rehearsal speed was related to 2 EF domains in the NH sample but was unrelated to EF outcomes in CI users. Perceptual encoding speed was related to all EF domains in both groups. Conclusions Verbal rehearsal speed may be less influential for EF quality in CI users than for NH controls, whereas rapid automatized labeling skills and EF are closely related in both groups. CI users may develop processing strategies in EF tasks that differ from the covert speech strategies routinely employed by NH individuals. PMID:25320961
Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea
2011-01-01
Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, S.; Bartoshesky, J.; Heimbuch, D.
1987-06-01
Contents include: data quality assurance and stream, precipitation, and meteorological data; Granny Finley Branch stream chemistry (routine sampling, storm-event chemistry, longitudinal sampling, groundwater chemistry).
RadNet Sampling and Analyses Schedules
RadNet air monitors operate continuously and samples of air, precipitation and drinking water and analyzed on a routine schedule. RadNet can send deployable monitors to any U.S. location in the case of a radiological emergency.
Michelin, Birgit D. A.; Hadžisejdić, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blaženka; Marth, Egon; Kessler, Harald H.
2008-01-01
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within ±0.5 log10 unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay. PMID:18272703
Michelin, Birgit D A; Hadzisejdic, Ita; Bozic, Michael; Grahovac, Maja; Hess, Markus; Grahovac, Blazenka; Marth, Egon; Kessler, Harald H
2008-04-01
Whole blood has been found to be a reliable matrix for the detection and quantitation of cytomegalovirus (CMV) DNA. In this study, the performance of the artus CMV LightCycler (LC) PCR kit in conjunction with automated sample preparation on a BioRobot EZ1 workstation was evaluated. The accuracy, linearity, analytical sensitivity, and inter- and intra-assay variations were determined. A total of 102 clinical EDTA whole-blood samples were investigated, and results were compared with those obtained with the in vitro diagnostics (IVD)/Conformité Européene (CE)-labeled CMV HHV6,7,8 R-gene quantification kit. When the accuracy of the new kit was tested, seven of eight results were found to be within +/-0.5 log(10) unit of the expected panel results. Determination of linearity resulted in a quasilinear curve over more than 5 log units. The lower limit of detection of the assay was determined to be 139 copies/ml in EDTA whole blood. The interassay variation ranged from 15 to 58%, and the intra-assay variation ranged from 7 to 35%. When clinical samples were tested and the results were compared with those of the routinely used IVD/CE-labeled assay, 53 samples tested positive and 13 samples tested negative by both of the assays. One sample was found to be positive with the artus CMV LC PCR kit only, and 35 samples tested positive with the routinely used assay only. The majority of discrepant results were found with low-titer samples. In conclusion, use of the artus CMV LC PCR kit in conjunction with automated sample preparation on the BioRobot EZ1 workstation may be suitable for the detection and quantitation of CMV DNA in EDTA whole blood in the routine low-throughput laboratory; however, low-positive results may be missed by this assay.
Quality control for quantitative PCR based on amplification compatibility test.
Tichopad, Ales; Bar, Tzachi; Pecen, Ladislav; Kitchen, Robert R; Kubista, Mikael; Pfaffl, Michael W
2010-04-01
Quantitative qPCR is a routinely used method for the accurate quantification of nucleic acids. Yet it may generate erroneous results if the amplification process is obscured by inhibition or generation of aberrant side-products such as primer dimers. Several methods have been established to control for pre-processing performance that rely on the introduction of a co-amplified reference sequence, however there is currently no method to allow for reliable control of the amplification process without directly modifying the sample mix. Herein we present a statistical approach based on multivariate analysis of the amplification response data generated in real-time. The amplification trajectory in its most resolved and dynamic phase is fitted with a suitable model. Two parameters of this model, related to amplification efficiency, are then used for calculation of the Z-score statistics. Each studied sample is compared to a predefined reference set of reactions, typically calibration reactions. A probabilistic decision for each individual Z-score is then used to identify the majority of inhibited reactions in our experiments. We compare this approach to univariate methods using only the sample specific amplification efficiency as reporter of the compatibility. We demonstrate improved identification performance using the multivariate approach compared to the univariate approach. Finally we stress that the performance of the amplification compatibility test as a quality control procedure depends on the quality of the reference set. Copyright 2010 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Orta, D.; Mudgett, P. D.; Ding, L.; Drybread, M.; Schultz, J. R.; Sauer, R. L.
1998-01-01
Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.
Simulation of Wind Profile Perturbations for Launch Vehicle Design
NASA Technical Reports Server (NTRS)
Adelfang, S. I.
2004-01-01
Ideally, a statistically representative sample of measured high-resolution wind profiles with wavelengths as small as tens of meters is required in design studies to establish aerodynamic load indicator dispersions and vehicle control system capability. At most potential launch sites, high- resolution wind profiles may not exist. Representative samples of Rawinsonde wind profiles to altitudes of 30 km are more likely to be available from the extensive network of measurement sites established for routine sampling in support of weather observing and forecasting activity. Such a sample, large enough to be statistically representative of relatively large wavelength perturbations, would be inadequate for launch vehicle design assessments because the Rawinsonde system accurately measures wind perturbations with wavelengths no smaller than 2000 m (1000 m altitude increment). The Kennedy Space Center (KSC) Jimsphere wind profiles (150/month and seasonal 2 and 3.5-hr pairs) are the only adequate samples of high resolution profiles approx. 150 to 300 m effective resolution, but over-sampled at 25 m intervals) that have been used extensively for launch vehicle design assessments. Therefore, a simulation process has been developed for enhancement of measured low-resolution Rawinsonde profiles that would be applicable in preliminary launch vehicle design studies at launch sites other than KSC.
Hb variants in Korea: effect on HbA1c using five routine methods.
Yun, Yeo-Min; Ji, Misuk; Ko, Dae-Hyun; Chun, Sail; Kwon, Gye Cheol; Lee, Kyunghoon; Song, Sang Hoon; Seong, Moon Woo; Park, Sung Sup; Song, Junghan
2017-07-26
Quantification of glycated hemoglobin (HbA1c) is a challenge in patients with hemoglobin (Hb) variants. We evaluated the impact of various Hb variants on five routine HbA1c assays by comparing with the IFCC reference measurement procedure (RMP). Whole blood samples showing warning flags or no results on routine HPLC HbA1c assays were confirmed for Hb variants and were submitted to HbA1c quantification using Sebia Capillarys 2 Flex Piercing, Roche Tina-quant HbA1c Gen. 2, Bio-Rad Variant II Turbo 2.0, ADAMS HA-8180, Tosoh G8 standard mode, and IFCC RMP using LC-MS. Among 114 samples, the most common variants were Hb G-Coushatta (n=47), Queens (n=41), Ube-4 (n=11), Chad (n=4), Yamagata (n=4), G-His-Tsou (n=2), G-Taipei (n=1), Fort de France (n=1), Hoshida (n=1), and two novel variants (Hb α-globin, HBA 52 Gly>Cys and Hb β-globin, HBB 146 His>Asn). In terms of control samples, all the result of HbA1c were "acceptable", within the criteria of ±7% compared to IFCC RMP target values. However, percentage of "unacceptable" results of samples with Hb variants were 16% for Capillarys 2, 7% for Tina-quant, 51% for Variant II Turbo 2.0, 95% for G8 standard mode, and 89% for HA-8180. The Capillarys 2 and HA-8180 assay did not provide the results in 5 and 40 samples with Hb variants, respectively. HbA1c results from five routine assays in patients with relatively common Hb variants in Korea showed various degrees of bias compared to those of IFCC RMP. Therefore, laboratories should be aware of the limitation of their methods with respect to interference from Hb variants found commonly in their local population and suggest an alternative HbA1c quantification method.
Lauritzen, Camilla; Reedtz, Charlotte; Van Doesum, Karin T M; Martinussen, Monica
2014-02-07
Mental health problems are often transmitted from one generation to the next. This knowledge has led to changes in Norwegian legislation, making it mandatory to assess whether or not patients have children, and to provide necessary support for the children of mentally ill patients. The main purpose of this study was to evaluate the process of implementing new routines in adult mental health services to identify and support children of mentally ill parents. The design was a pre-test post-test study. The sample (N = 219 at pre-test and N = 185 at post-test) included mental health professionals in the largest hospital in the region, who responded to a web-based survey on the routines of the services, attitudes within the workforce capacity, worker's knowledge on the impact of parental mental illness on children, knowledge on legislation concerning children of patients, and demographic variables. The results of this study indicated that some changes are taking place in clinical practice in terms of increased identification of children. Adult mental health services providing support for the children was however not fully implemented as a new practice. The main finding in this study is that the identification frequency had increased significantly according to self-reported data since the Family Assessment Form was implemented. The increase in self-reported identification behavior is however taking place very slowly. Three years after the legislation was changed to making it mandatory to assess whether or not patients have children, it was still not fully incorporated in the routines of the entire workforce. In terms of support for the families affected by parental mental illness, the changes are not yet significant.
2014-01-01
Background Mental health problems are often transmitted from one generation to the next. This knowledge has led to changes in Norwegian legislation, making it mandatory to assess whether or not patients have children, and to provide necessary support for the children of mentally ill patients. The main purpose of this study was to evaluate the process of implementing new routines in adult mental health services to identify and support children of mentally ill parents. Methods The design was a pre-test post-test study. The sample (N = 219 at pre-test and N = 185 at post-test) included mental health professionals in the largest hospital in the region, who responded to a web-based survey on the routines of the services, attitudes within the workforce capacity, worker’s knowledge on the impact of parental mental illness on children, knowledge on legislation concerning children of patients, and demographic variables. Results The results of this study indicated that some changes are taking place in clinical practice in terms of increased identification of children. Adult mental health services providing support for the children was however not fully implemented as a new practice. Conclusion The main finding in this study is that the identification frequency had increased significantly according to self-reported data since the Family Assessment Form was implemented. The increase in self-reported identification behavior is however taking place very slowly. Three years after the legislation was changed to making it mandatory to assess whether or not patients have children, it was still not fully incorporated in the routines of the entire workforce. In terms of support for the families affected by parental mental illness, the changes are not yet significant. PMID:24507566
The Use of Recommended Communication Techniques by Maryland Family Physicians and Pediatricians
Weatherspoon, Darien J.; Horowitz, Alice M.; Kleinman, Dushanka V.; Wang, Min Qi
2015-01-01
Background Health literacy experts and the American Medical Association have developed recommended communication techniques for healthcare providers given that effective communication has been shown to greatly improve health outcomes. The purpose of this study was to determine the number and types of communication techniques routinely used by Maryland physicians. Methods In 2010, a 30-item survey was mailed to a random sample of 1,472 Maryland family physicians and pediatricians, with 294 surveys being returned and usable. The survey contained questions about provider and practice characteristics, and 17 items related to communication techniques, including seven basic communication techniques. Physicians’ use of recommended communication techniques was analyzed using descriptive statistics, analysis of variance, and ordinary least squares regression. Results Family physicians routinely used an average of 6.6 of the 17 total techniques and 3.3 of the seven basic techniques, whereas pediatricians routinely used 6.4 and 3.2 techniques, respectively. The use of simple language was the only technique that nearly all physicians routinely utilized (Family physicians, 91%; Pediatricians, 93%). Physicians who had taken a communications course used significantly more techniques than those who had not. Physicians with a low percentage of patients on Medicaid were significantly less likely to use the recommended communication techniques compared to those providers who had high proportion of their patient population on Medicaid. Conclusions Overall, the use of recommended communication techniques was low. Additionally, many physicians were unsure of the effectiveness of several of the recommended techniques, which could suggest that physicians are unaware of valuable skills that could enhance their communication. The findings of this study suggest that communications training should be given a higher priority in the medical training process in the United States. PMID:25856371
Stefanelli, Fabio; Pesci, Federica Giorgia; Giusiani, Mario; Chericoni, Silvio
2018-04-01
A novel aqueous in situ derivatization procedure with propyl chloroformate (PCF) for the simultaneous, quantitative analysis of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxy-Δ 9 -tetrahydrocannabinol (OH-THC) and 11-nor-Δ 9 -tetrahydrocannabinol-carboxylic acid (THC-COOH) in human blood and urine is proposed. Unlike current methods based on the silylating agent [N,O-bis(trimethylsilyl)trifluoroacetamide] added in an anhydrous environment, this new proposed method allows the addition of the derivatizing agent (propyl chloroformate, PCF) directly to the deproteinized blood and recovery of the derivatives by liquid-liquid extraction. This novel method can be also used for hydrolyzed urine samples. It is faster than the traditional method involving a derivatization with trimethyloxonium tetrafluoroborate. The analytes are separated, detected and quantified by gas chromatography-mass spectrometry in selected ion monitoring mode (SIM). The method was validated in terms of selectivity, capacity of identification, limits of detection (LOD) and quantification (LOQ), carryover, linearity, intra-assay precision, inter-assay precision and accuracy. The LOD and LOQ in hydrolyzed urine were 0.5 and 1.3 ng/mL for THC and 1.2 and 2.6 ng/mL for THC-COOH, respectively. In blood, the LOD and LOQ were 0.2 and 0.5 ng/mL for THC, 0.2 and 0.6 ng/mL for OH-THC, and 0.9 and 2.4 ng/mL for THC-COOH, respectively. This method was applied to 35 urine samples and 50 blood samples resulting to be equivalent to the previously used ones with the advantage of a simpler method and faster sample processing time. We believe that this method will be a more convenient option for the routine analysis of cannabinoids in toxicological and forensic laboratories. Copyright © 2017 John Wiley & Sons, Ltd.
Parkinson, I S; Ward, M K; Kerr, D N
1982-10-27
A simple but reliable method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry is described. No preparatory procedures are required for water samples, although serum is mixed with a wetting agent (Triton X-100) to allow complete combustion of the samples and to improve analytical precision. Precautions to prevent contamination during sample handling are discussed and instrumental parameters are defined. The method has a sensitivity of 35.5 pg and detection limits of 2.3 micrograms Al/l for serum and 1.3 micrograms Al/l for water. The method was used to determine the aluminium concentration in serum of 46 normal subjects. The mean aluminium content was 7.3 micrograms/l (range 2--15 micrograms/l.
Honda, Takayuki; Tozuka, Minoru
2015-09-01
In the reversed clinicopathological conference (R-CPC), three specialists in laboratory medicine interpreted routine laboratory data independently in order to understand the detailed state of a patient. R-CPC is an educational method to use laboratory data appropriately, and it is also important to select differential diagnoses in a process of clinical reasoning in addition to the present illness and physical examination. Routine laboratory tests can be performed repeatedly at a relatively low cost, and their time-series analysis can be performed. Interpretation of routine laboratory data is almost the same as taking physical findings. General findings are initially checked and then the state of each organ is examined. Although routine laboratory tests cost little, we can gain much more information from them about the patient than physical examinations.
Evaluation of soil water stable isotope analysis by H2O(liquid)-H2O(vapor) equilibration method
NASA Astrophysics Data System (ADS)
Gralher, Benjamin; Stumpp, Christine
2014-05-01
Environmental tracers like stable isotopes of water (δ18O, δ2H) have proven to be valuable tools to study water flow and transport processes in soils. Recently, a new technique for soil water isotope analysis has been developed that employs a vapor phase being in isothermal equilibrium with the liquid phase of interest. This has increased the potential application of water stable isotopes in unsaturated zone studies as it supersedes laborious extraction of soil water. However, uncertainties of analysis and influencing factors need to be considered. Therefore, the objective of this study was to evaluate different methodologies of analysing stable isotopes in soil water in order to reduce measurement uncertainty. The methodologies included different preparation procedures of soil cores for equilibration of vapor and soil water as well as raw data correction. Two different inflatable sample containers (freezer bags, bags containing a metal layer) and equilibration atmospheres (N2, dry air) were tested. The results showed that uncertainties for δ18O were higher compared to δ2H that cannot be attributed to any specific detail of the processing routine. Particularly, soil samples with high contents of organic matter showed an apparent isotope enrichment which is indicative for fractionation due to evaporation. However, comparison of water samples obtained from suction cups with the local meteoric water line indicated negligible fractionation processes in the investigated soils. Therefore, a method was developed to correct the raw data reducing the uncertainties of the analysis.. We conclude that the evaluated method is advantageous over traditional methods regarding simplicity, resource requirements and sample throughput but careful consideration needs to be made regarding sample handling and data processing. Thus, stable isotopes of water are still a good tool to determine water flow and transport processes in the unsaturated zone.
Environmental surveillance master sampling schedule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bisping, L.E.
This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of themore » onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.« less
Recent improvements in hydrometeor sampling using airborne holography
NASA Astrophysics Data System (ADS)
Stith, J. L.; Bansemer, A.; Glienke, S.; Shaw, R. A.; Aquino, J.; Fugal, J. P.
2017-12-01
Airborne digital holography provides a new technique to study the sizes, shapes and locations of hydrometeors. Airborne holographic cameras are able to capture more optical information than traditional airborne hydrometeor instruments, which allows for more detailed information, such as the location and shape of individual hydrometeors over a relatively wide range of sizes. These cameras can be housed in an anti-shattering probe arm configuration, which minimizes the effects of probe tip shattering. Holographic imagery, with its three dimensional view of hydrometeor spacing, is also well suited to detecting shattering events when present. A major problem with digital holographic techniques has been the amount of machine time and human analysis involved in analyzing holographic data. Here, we present some recent examples showing how holographic analysis can improve our measurements of liquid and ice particles and we describe a format we have developed for routine archiving of Holographic data, so that processed results can be utilized more routinely by a wider group of investigators. We present a side-by-side comparison of the imagery obtained from holographic reconstruction of ice particles from a holographic camera (HOLODEC) with imagery from a 3VCPI instrument, which utilizes a tube-based sampling geometry. Both instruments were carried on the NSF/NCAR GV aircraft. In a second application of holographic imaging, we compare measurements of cloud droplets from a Cloud Droplet Probe (CDP) with simultaneous measurements from HOLODEC. In some cloud regions the CDP data exhibits a bimodal size distribution, while the more local data from HOLODEC suggests that two mono-modal size distributions are present in the cloud and that the bimodality observed in the CDP is due to the averaging length. Thus, the holographic techniques have the potential to improve our understanding of the warm rain process in future airborne field campaigns. The development of this instrument has been a university and national lab collaboration. Progress in automating the processing techniques has now reached a stage where processed data can be made readily available, so that holographic data from a field campaign can be utilized by a wider group of investigators.
Xiao, Ting; Stamatakis, Katherine A; McVay, Allese B
Local health departments (LHDs) have an important function in controlling the growing epidemic of obesity in the United States. Data are needed to gain insight into the existence of routine functions and structures of LHDs that support and sustain obesity prevention efforts. The purpose of this study was to develop and examine the reliability of measures to assess foundational LHD organizational processes and functions specific to obesity prevention. Survey measures were developed using a stratified, random sample of US LHDs to assess supportive organizational processes and infrastructure for obesity prevention representing different domains. Data were analyzed using weighted κ and intraclass correlation coefficient for assessing test-retest reliability. Most items and summary indices in the majority of survey domains had moderate/substantial or almost perfect reliability. The overall findings support this survey instrument to be a reliable measurement tool for a large number of processes and functions that comprise obesity prevention-related capacity in LHDs.
Strong, James Asa; Elliott, Michael
2017-03-15
The reporting of ecological phenomena and environmental status routinely required point observations, collected with traditional sampling approaches to be extrapolated to larger reporting scales. This process encompasses difficulties that can quickly entrain significant errors. Remote sensing techniques offer insights and exceptional spatial coverage for observing the marine environment. This review provides guidance on (i) the structures and discontinuities inherent within the extrapolative process, (ii) how to extrapolate effectively across multiple spatial scales, and (iii) remote sensing techniques and data sets that can facilitate this process. This evaluation illustrates that remote sensing techniques are a critical component in extrapolation and likely to underpin the production of high-quality assessments of ecological phenomena and the regional reporting of environmental status. Ultimately, is it hoped that this guidance will aid the production of robust and consistent extrapolations that also make full use of the techniques and data sets that expedite this process. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Tarancón, A.; García, J. F.; Rauret, G.
2004-01-01
Plastic scintillation has recently been shown to be a powerful alternative to liquid scintillation and Cherenkov techniques in radionuclide determination due to the good values obtained for the measurement parameters and the low amount of wastes generated. The present study evaluated the capability of plastic scintillation beads and polyethylene vials for routine measurements of beta emitters ( 90Sr, 14C, 3H). Results show that high- and medium-energetic beta emitters can be quantified with relative errors less than 5% in low-activity aqueous samples, whereas low-energetic beta emitters can only be quantified in medium-activity samples.
An Input Routine Using Arithmetic Statements for the IBM 704 Digital Computer
NASA Technical Reports Server (NTRS)
Turner, Don N.; Huff, Vearl N.
1961-01-01
An input routine has been designed for use with FORTRAN or SAP coded programs which are to be executed on an IBM 704 digital computer. All input to be processed by the routine is punched on IBM cards as declarative statements of the arithmetic type resembling the FORTRAN language. The routine is 850 words in length. It is capable of loading fixed- or floating-point numbers, octal numbers, and alphabetic words, and of performing simple arithmetic as indicated on input cards. Provisions have been made for rapid loading of arrays of numbers in consecutive memory locations.
Routine Work Environment Stress and PTSD Symptoms in Police Officers
Maguen, Shira; Metzler, Thomas J.; McCaslin, Shannon E.; Inslicht, Sabra S.; Henn-Haase, Clare; Neylan, Thomas C.; Marmar, Charles R.
2013-01-01
This study examined the relationship between routine work environment stress and posttraumatic stress disorder (PTSD) symptoms in a sample of police officers (N = 180) who were first assessed during academy training and reassessed 1-year later. In a model that included gender, ethnicity, traumatic exposure prior to entering the academy, current negative life events, and critical incident exposure over the last year, routine work environment stress was most strongly associated with PTSD symptoms. We also found that routine work environment stress mediated the relationship between critical incident exposure and PTSD symptoms and between current negative life events and PTSD symptoms. Ensuring that the work environment is functioning optimally protects against the effects of duty-related critical incidents and negative life events outside police service. PMID:19829204
Snyder, Jamie A
2015-11-01
Using data from a nationally representative sample of college women, the current study examines attention deficit hyperactivity disorder (ADHD) as a potential risk factor in the prediction of sexual victimization among college women and as an extension of the lifestyles/routine activities framework. The findings indicate that college women with ADHD experienced sexual victimization at significantly higher rates than college women without ADHD. Furthermore, ADHD emerged as a significant predictor of sexual victimization across models. The lifestyles/routine activities theory also received general support, particularly for the concepts of exposure, proximity, and guardianship. This research suggests that other risk factors outside the lifestyles/routine activities framework are important in the prediction of sexual victimization in college women. © The Author(s) 2015.
Improved Air Combat Awareness; with AESA and Next-Generation Signal Processing
2002-09-01
competence network Building techniques Software development environment Communication Computer architecture Modeling Real-time programming Radar...memory access, skewed load and store, 3.2 GB/s BW • Performance: 400 MFLOPS Runtime environment Custom runtime routines Driver routines Hardware
Mourah, Samia; Denis, Marc G.; Narducci, Fabienne Escande; Solassol, Jérôme; Merlin, Jean-Louis; Sabourin, Jean-Christophe; Scoazec, Jean-Yves; Ouafik, L’Houcine; Emile, Jean-François; Heller, Remy; Souvignet, Claude; Bergougnoux, Loïc; Merlio, Jean-Philippe
2015-01-01
Vemurafenib is approved for the treatment of metastatic melanoma in patients with BRAF V600 mutation. In pivotal clinical trials, BRAF testing has always been done with the approved cobas 4800 BRAF test. In routine practice, several methods are available and are used according to the laboratories usual procedures. A national, multicenter, non-interventional study was conducted with prospective and consecutive collection of tumor samples. A parallel evaluation was performed in routine practice between the cobas 4800 BRAF V600 mutation test and home brew methods (HBMs) of 12 national laboratories, labelled and funded by the French National Cancer Institute (INCa). For 420 melanoma samples tested, the cobas method versus HBM showed a high concordance (93.3%; kappa = 0.86) in BRAF V600 genotyping with similar mutation rates (34.0% versus 35.7%, respectively). Overall, 97.4% and 98.6% of samples gave valid results using the cobas and HBM, respectively. Of the 185 samples strictly fulfilling the cobas guidelines, the concordance rate was even higher (95.7%; kappa = 0.91; 95%CI [0.85; 0.97]). Out of the 420 samples tested, 28 (6.7%) showed discordance between HBM and cobas. This prospective study shows a high concordance rate between the cobas 4800 BRAF V600 test and home brew methods in the routine detection of BRAF V600E mutations. PMID:25789737
A FORTRAN program for determining aircraft stability and control derivatives from flight data
NASA Technical Reports Server (NTRS)
Maine, R. E.; Iliff, K. W.
1975-01-01
A digital computer program written in FORTRAN IV for the estimation of aircraft stability and control derivatives is presented. The program uses a maximum likelihood estimation method, and two associated programs for routine, related data handling are also included. The three programs form a package that can be used by relatively inexperienced personnel to process large amounts of data with a minimum of manpower. This package was used to successfully analyze 1500 maneuvers on 20 aircraft, and is designed to be used without modification on as many types of computers as feasible. Program listings and sample check cases are included.
Current trends in quantitative proteomics - an update.
Li, H; Han, J; Pan, J; Liu, T; Parker, C E; Borchers, C H
2017-05-01
Proteins can provide insights into biological processes at the functional level, so they are very promising biomarker candidates. The quantification of proteins in biological samples has been routinely used for the diagnosis of diseases and monitoring the treatment. Although large-scale protein quantification in complex samples is still a challenging task, a great amount of effort has been made to advance the technologies that enable quantitative proteomics. Seven years ago, in 2009, we wrote an article about the current trends in quantitative proteomics. In writing this current paper, we realized that, today, we have an even wider selection of potential tools for quantitative proteomics. These tools include new derivatization reagents, novel sampling formats, new types of analyzers and scanning techniques, and recently developed software to assist in assay development and data analysis. In this review article, we will discuss these innovative methods, and their current and potential applications in proteomics. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Morales Colón, Emely; Hernández, Mireya; Candelario, Mariel; Meléndez, María; Dawson Cruz, Tracey
2018-03-01
Traditional methods for bone pulverization typically generate heat, risking stability of DNA sample. SPEX™ has developed cryogenic grinders which introduce liquid nitrogen to cool the sample and aid in the grinding process. In this study, the Freezer Mill 6970 EFM was used with two DNA extraction methods and routine downstream STR analysis procedures. DNA from as little as 0.1 g of bone powder was used to develop full STR profiles after freezer mill pulverization, and the method was reproducible. Further, no contamination was detected upon cleaning/reuse of the sample vials. There were no significant differences in DNA yield, STR alleles detected, or peak heights using the freezer mill as compared to traditional grinding, and successful DNA profiles were achieved from as low as 0.1 g of bone powder with this method. Overall, this work indicates that this cryogenic mill method may be used as a viable alternative to traditional tissue grinders. © 2017 American Academy of Forensic Sciences.
ERIC Educational Resources Information Center
Schlebusch, L.; Samuels, A. E.; Dada, S.
2016-01-01
Background: The purpose of this study was to investigate the relationship between family routines, cognitive appraisal of the impact of autism spectrum disorders (ASD) on the family and family quality of life (FQOL) in families raising children with ASD in South Africa. Methods: A sample of 180 families of young children with ASD who were…
Hanmer, Lyn; Nicola, Edward; Bradshaw, Debbie
2017-01-01
The quality of morbidity data in multiple routine inpatient records in a sample of South African hospitals is being assessed in terms of data accuracy and completeness. Extensive modification of available data collection tools was required to make it possible to collect the required data for the study.
40 CFR 141.132 - Monitoring requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... discretion. (2) Chlorite. Community and nontransient noncommunity water systems using chlorine dioxide, for... samples. (ii) Reduced monitoring. Monitoring may not be reduced. (2) Chlorine dioxide—(i) Routine... three chlorine dioxide distribution system samples. If chlorine dioxide or chloramines are used to...
Spanjer, M; Stroka, J; Patel, S; Buechler, S; Pittet, A; Barel, S
2001-06-01
Mycotoxins contamination is highly non-uniformly distributed as is well recog-nized by the EC, by not only setting legal limits in a series of commodities, but also schedule a sampling plan that takes this heterogeneity into account. In practice however, it turns out that it is very difficult to carry out this sampling plan in a harmonised way. Applying the sampling plan to a container filled with pallets of bags (i.e. with nuts or coffee beans) varies from very laborious to almost impossible. The presented non-destructive automated method to sample bulk food could help to overcome these practical problems and to enforcing of EC directives. It is derived from a tested and approved technology for detection of illicit substances in security applications. It has capability to collect and iden-tify ultra trace contaminants, i.e. from a fingerprint of chemical substance in a bulk of goods, a cargo pallet load (~ 1000 kg) with boxes and commodities.The technology, patented for explosives detection, uses physical and chemistry processes for excitation and remote rapid enhanced release of contaminant residues, vapours and particulate, of the inner/outer surfaces of inspected bulk and collect them on selective probes. The process is automated, takes only 10 minutes, is non-destructive and the bulk itself remains unharmed. The system design is based on applicable international regulations for shipped cargo hand-ling and transportation by road, sea and air. After this process the pallet can be loaded on a truck, ship or plane. Analysis can be carried out before the cargo leaves the place of shipping. The potent application of this technology for myco-toxins detection, has been demonstrated by preliminary feasibility experiments. Aflatoxins were detected in pistachios and ochratoxin A in green coffee beans bulk. Both commodities were naturally contaminated, priory found and confirm-ed by common methods as used at routine inspections. Once the contaminants are extracted from a bulk shipment, an appropriate existing analytical method, i.e. a CEN method, can be used to measure the mycotoxins.The system, routinely in use for explosives detection, was able to screen bulk food and feed for mycotoxins, through non-destructive automated sampling of a whole batch/lot/sublot of commodities. The opportunity to sample a whole bulk would provide more effective tools for inspection at seaports, production facili-ties and distri-bution points. It will advance the current process of myco-toxins check because: (i) Checks will be automated and harmonized, (ii) Checks will be non-destructive, (iii) Checks will be faster and allow a greater amount of bulk commodities to be inspected and (iv) The ability to check, with automated equipment, larger portions of lots of a shipment will increase the probability to detect the heterogeneous mycotoxins contamination in bulk foods. The poster provides some results of feasibility experiments indicating the capability of this technology for inspection of commodities bulks for the detection of mycotoxins, at legal limits, in naturally contaminated food.
Vikingsson, Svante; Carlsson, Björn; Almer, Sven H C; Peterson, Curt
2009-06-01
Azathioprine and 6-mercaptopurine are often used in the treatment of patients with inflammatory bowel disease (IBD). They are prodrugs and undergo a complex metabolism to active and inactive metabolites. Thiopurine treatment is monitored in many laboratories by measuring metabolite concentrations in erythrocytes (red blood cells). The metabolites of interest are not measured directly but as hydrolysis products, which can be produced from several metabolites. The aim of this study was to examine which metabolites are actually measured during routine monitoring. Samples from 18 patients treated with a thiopurine were analyzed by a typical routine high-performance liquid chromatography method for therapeutic drug monitoring and by a newly developed specific method measuring thioguanosine monophosphate (TGMP), thioguanosine diphosphate (TGDP), and thioguanosine triphosphate (TGTP), as well as methylthioinosine monophosphate (meTIMP), and the results were compared. 6-Thioguanine nucleotide (TGN) values detected by the routine method were 69% (range 40%-90%) of the sum of TGMP, TGDP, and TGTP measured by the specific method. TGTP and TGDP contributed 85% (range 78%-90%) and 14% (range 10%-21%) of the TGN total, respectively. Thioguanosine was not found in any patient sample. The concentration of meTIMP obtained by the routine method was 548% of the value obtained by the specific method (range 340%-718%). The difference in TGN measurements between the routine and specific methods can be explained by low hydrolysis efficiency in the routine method, although the most likely explanation for the difference in meTIMP values is that not yet identified metabolites are codetermined in the routine high-performance liquid chromatography method. Concentrations reported as TGN during therapeutic drug monitoring of thiopurine metabolites consist of TGDP and TGTP with a minor contribution of the TGMP. Concentrations reported as meTIMP or methyl mercaptopurine consist in part of meTIMP, but other not yet identified metabolites are codetermined.
Metal speciation of environmental samples using SPE and SFC-AED analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitchell, S.C.; Burford, M.D.; Robson, M.
1995-12-31
Due to growing public concern over heavy metals in the environment, soil, water and air particulate samples azre now routinely screened for their metal content. Conventional metal analysis typically involves acid digestion extraction and results in the generation of large aqueous and organic solvent waste. This harsh extraction process is usually used to obtain the total metal content of the sample, the extract being analysed by atomic emission or absorption spectroscoply techniques. A more selective method of metal extraction has been investigated which uses a supercritical fluid modified with a complexing agent. The relatively mild extraction method enables both organometallicmore » and inorganic metal species to be recovered intact. The various components from the supercritical fluid extract can be chromatographically separated using supercritical fluid chromatography (SFC) and positive identification of the metals achieved using atomic emission detection (AED). The aim of the study is to develop an analytical extraction procedure which enables a rapid, sensitive and quantitative analysis of metals in environmental samples, using just one extraction (eg SFE) and one analysis (eg SFC-AED) procedure.« less
RNA-SeQC: RNA-seq metrics for quality control and process optimization.
DeLuca, David S; Levin, Joshua Z; Sivachenko, Andrey; Fennell, Timothy; Nazaire, Marc-Danie; Williams, Chris; Reich, Michael; Winckler, Wendy; Getz, Gad
2012-06-01
RNA-seq, the application of next-generation sequencing to RNA, provides transcriptome-wide characterization of cellular activity. Assessment of sequencing performance and library quality is critical to the interpretation of RNA-seq data, yet few tools exist to address this issue. We introduce RNA-SeQC, a program which provides key measures of data quality. These metrics include yield, alignment and duplication rates; GC bias, rRNA content, regions of alignment (exon, intron and intragenic), continuity of coverage, 3'/5' bias and count of detectable transcripts, among others. The software provides multi-sample evaluation of library construction protocols, input materials and other experimental parameters. The modularity of the software enables pipeline integration and the routine monitoring of key measures of data quality such as the number of alignable reads, duplication rates and rRNA contamination. RNA-SeQC allows investigators to make informed decisions about sample inclusion in downstream analysis. In summary, RNA-SeQC provides quality control measures critical to experiment design, process optimization and downstream computational analysis. See www.genepattern.org to run online, or www.broadinstitute.org/rna-seqc/ for a command line tool.
Morrell, J M; Wallgren, M
2011-01-01
There is considerable interest world-wide in reducing the use of antibiotics to stem the development of antibiotic-resistant strains of bacteria. An alternative to the routine addition of antibiotics to semen extenders in livestock breeding would be to separate the spermatozoa from bacterial contaminants in the semen immediately after collection. The present study was designed to determine whether such separation was possible by Single Layer Centrifugation (SLC) using the colloid Androcoll™-P. The results showed that complete removal (6 out of 10 samples), or considerable reduction of bacterial contaminants (4 out of 10 samples) was possible with this method. The type of bacteria and/or the length of time between collection and SLC-processing affected the removal of bacteria, with motile flagellated bacteria being more likely to be present after SLC than non-flagellated bacteria. Although further studies are necessary, these preliminary results suggest that the use of SLC when processing boar semen for AI doses might enable antibiotic usage in semen extenders to be reduced. Copyright © 2010 Elsevier B.V. All rights reserved.
Simultaneous inference of phylogenetic and transmission trees in infectious disease outbreaks
2017-01-01
Whole-genome sequencing of pathogens from host samples becomes more and more routine during infectious disease outbreaks. These data provide information on possible transmission events which can be used for further epidemiologic analyses, such as identification of risk factors for infectivity and transmission. However, the relationship between transmission events and sequence data is obscured by uncertainty arising from four largely unobserved processes: transmission, case observation, within-host pathogen dynamics and mutation. To properly resolve transmission events, these processes need to be taken into account. Recent years have seen much progress in theory and method development, but existing applications make simplifying assumptions that often break up the dependency between the four processes, or are tailored to specific datasets with matching model assumptions and code. To obtain a method with wider applicability, we have developed a novel approach to reconstruct transmission trees with sequence data. Our approach combines elementary models for transmission, case observation, within-host pathogen dynamics, and mutation, under the assumption that the outbreak is over and all cases have been observed. We use Bayesian inference with MCMC for which we have designed novel proposal steps to efficiently traverse the posterior distribution, taking account of all unobserved processes at once. This allows for efficient sampling of transmission trees from the posterior distribution, and robust estimation of consensus transmission trees. We implemented the proposed method in a new R package phybreak. The method performs well in tests of both new and published simulated data. We apply the model to five datasets on densely sampled infectious disease outbreaks, covering a wide range of epidemiological settings. Using only sampling times and sequences as data, our analyses confirmed the original results or improved on them: the more realistic infection times place more confidence in the inferred transmission trees. PMID:28545083
Simultaneous inference of phylogenetic and transmission trees in infectious disease outbreaks.
Klinkenberg, Don; Backer, Jantien A; Didelot, Xavier; Colijn, Caroline; Wallinga, Jacco
2017-05-01
Whole-genome sequencing of pathogens from host samples becomes more and more routine during infectious disease outbreaks. These data provide information on possible transmission events which can be used for further epidemiologic analyses, such as identification of risk factors for infectivity and transmission. However, the relationship between transmission events and sequence data is obscured by uncertainty arising from four largely unobserved processes: transmission, case observation, within-host pathogen dynamics and mutation. To properly resolve transmission events, these processes need to be taken into account. Recent years have seen much progress in theory and method development, but existing applications make simplifying assumptions that often break up the dependency between the four processes, or are tailored to specific datasets with matching model assumptions and code. To obtain a method with wider applicability, we have developed a novel approach to reconstruct transmission trees with sequence data. Our approach combines elementary models for transmission, case observation, within-host pathogen dynamics, and mutation, under the assumption that the outbreak is over and all cases have been observed. We use Bayesian inference with MCMC for which we have designed novel proposal steps to efficiently traverse the posterior distribution, taking account of all unobserved processes at once. This allows for efficient sampling of transmission trees from the posterior distribution, and robust estimation of consensus transmission trees. We implemented the proposed method in a new R package phybreak. The method performs well in tests of both new and published simulated data. We apply the model to five datasets on densely sampled infectious disease outbreaks, covering a wide range of epidemiological settings. Using only sampling times and sequences as data, our analyses confirmed the original results or improved on them: the more realistic infection times place more confidence in the inferred transmission trees.
Physicochemical characterization of mineral deposits in human ligamenta flava.
Orzechowska, Sylwia; Wróbel, Andrzej; Kozieł, Marcin; Łasocha, Wiesław; Rokita, Eugeniusz
2018-05-01
The aim of our study was the detailed characterization of calcium deposits in ligamenta flava. The use of microcomputed tomography allowed extending the routine medical investigations to characterize mineral grains in the microscopic scale. A possible connection between spinal stenosis and ligament mineralization was investigated. The studies were carried out on 24 surgically removed ligamentum flavum samples divided into control and stenosis groups. Physicochemical characterization of the inorganic material was performed using X-ray fluorescence, X-ray diffraction, and Fourier transform infrared spectroscopy. The minerals were present in 14 of 24 ligament samples, both in stenosis and control groups. The inorganic substance constitutes on average ~0.1% of the sample volume. The minerals are scattered in the soft tissue matrix without any regular pattern. It was confirmed that minerals possess an internal structure and consist of the organic material and small inorganic grains mixture. The physicochemical analyses show that the predominant crystalline phase was hydroxyapatite (HAP). In the stenosis group calcium pyrophosphate dehydrate (CPPD) was identified. Both structures were never present in a single sample. Two different crystal structures suggest two independent processes of mineralization. The formation of CPPD may be treated as a more intense process since CPPD minerals are characterized by bigger values of the structural parameters and higher density than HAP deposits. The formation of HAP minerals is a soft tissue degeneration process that begins, in some cases, at early age or may not occur at all. Various density and volume of mineral grains indicate that the mineralization process does not occur in a constant environment and proceeds with various speeds. The formation of minerals in ligamenta flava is not directly associated with diagnosed spinal canal stenosis.
Schellenberg, François; Mennetrey, Louise; Girre, Catherine; Nalpas, Bertrand; Pagès, Jean Christophe
2008-01-01
In this study, we evaluated the new %CDT by the HPLC method (Bio-Rad, Germany) on a Varianttrade mark HPLC system (Bio-Rad), checked the correlation with well-known methods and calculated the diagnostic value of the test. Intra-run and day-to-day precision values were calculated for samples with extreme serum transferrin concentrations, high trisialotransferrin and interfering conditions (haemolysed, lactescent and icteric samples). The method was compared with two routine procedures, the %CDT TIA (Bio-Rad, Hercules, CA, USA) and the Capillarystrade mark CDT (Sebia, France). A total of 350 clinical sera samples were used for a case-control study. Precision values were better in high CDT and medium CDT pools than in low CDT pools. The serum transferrin concentration had no effect on CDT measurement, except in samples with serum transferrin <1 g/L. Haemolysis was the only interfering situation. The method showed high correlation (r(2) > 0.95) with the two other methods (%CDT TIA and CZE %CDT). The global predictive value of the test was >0.90 at 1.9% cut-off. These results demonstrate that the %CDT by the HPLC test is suitable for CDT routine measurement; the results from the high-throughput Varianttrade mark system are well correlated with other methods and are of high diagnostic value.
Tips and traps in the 14C bio-AMS preparation laboratory
NASA Astrophysics Data System (ADS)
Buchholz, Bruce A.; Freeman, Stewart P. H. T.; Haack, Kurt W.; Vogel, John S.
2000-10-01
Maintaining a contamination free sample preparation lab for biological 14C AMS requires the same or more diligence as a radiocarbon dating prep lab. Isotope ratios of materials routinely range over 4-8 orders of magnitude in a single experiment, dosing solutions contain thousands of DPM and gels used to separate proteins possess 14C ratios of 1 amol 14C/mg C. Radiocarbon contamination is a legacy of earlier tracer work in most biological laboratories, even if they were never hot labs. Removable surface contamination can be found and monitored using swipes. Contamination can be found on any surface routinely touched: door knobs, light switches, drawer handles, water faucets. In general, all surfaces routinely touched need to be covered with paper, foil or plastic that can be changed frequently. Shared air supplies can also present problems by distributing hot aerosols throughout a building. Aerosols can be monitored for 14C content using graphitized coal or fullerene soot mixed with metal powder as an absorber. The monitors can be set out in work spaces for 1-2 weeks and measured by AMS with regular samples. Frequent air changes help minimize aerosol contamination in many cases. Cross-contamination of samples can be minimized by using disposable plastic or glassware in the prep lab, isolating samples from the air when possible and using positive displacement pipettors.
Gargano, Lisa M; Thacker, Naveen; Choudhury, Panna; Weiss, Paul S; Pazol, Karen; Bahl, Sunil; Jafari, Hamid S; Arora, Manisha; Orenstein, Walter A; Hughes, James M; Omer, Saad B
2012-05-21
According to the World Health Organization in 2008, pneumonia accounted for 20% of deaths and diarrheal diseases accounted for 13% of deaths among children under 5 in India. Vaccines are available for Streptococcus pneumoniae (pneumococcal conjugate vaccine (PCV)), Haemophilus influenzae type b (Hib vaccine), and rotavirus. Barriers to including these vaccines in routine immunization schedule in India include potential negative impacts on fragile existing immunization programs and cost. Pediatricians who are members of the Indian Academy of Pediatrics (IAP) are important stakeholders for vaccine delivery and maintaining public confidence in vaccines. A random sample of 785 pediatricians belonging to IAP was selected for the survey conducted from June 2009 to June 2010. Descriptive analyses using sampling weights were performed to evaluate the distributions of variables assessing vaccine-related attitudes and behaviors among pediatricians. Logistic regression was used to assess factors associated with routine vaccine use. The majority of pediatricians reported administering PCV (85.6%), Hib (95.9%), and rotavirus (80.2%) vaccine selectively or routinely. Pediatricians who had high perceived disease susceptibility were 2.42 times more likely to report routine administration of Hib vaccine (OR 2.42, 95% CI 1.24, 4.74). Pediatricians who had high perceived Hib vaccine efficacy were 4.74 times more likely to administer Hib vaccine routinely (OR 4.74, 95% CI 2.09, 10.74). Perceptions of disease susceptibility and severity or of vaccine safety and efficacy were not associated with routine administration of PCV or rotavirus vaccine. Understanding predictors of routine use of a new vaccine could help focus interventions to improve the routine use of other vaccines. The importance of perceived susceptibility to and severity of diseases caused by S. pneumoniae, Hib, and rotavirus and perceived efficacy and safety of the vaccines by pediatricians presents an opportunity to design strategies to build support for new vaccine introduction and may have important implications for national immunization policy in India. Copyright © 2012 Elsevier Ltd. All rights reserved.
Nagy, M; Otremba, P; Krüger, C; Bergner-Greiner, S; Anders, P; Henske, B; Prinz, M; Roewer, L
2005-08-11
Automated procedures for forensic DNA analyses are essential not only for large-throughput sample preparation, but are also needed to avoid errors during routine sample preparation. The most critical stage in PCR-based forensic analysis is DNA isolation, which should yield as much highly purified DNA as possible. The extraction method used consists of pre-treatment of stains and samples, cell lysis using chaotropic reagents, binding of the DNA to silica-coated magnetic particles, followed by elution of the DNA. Our work focuses mainly on sample preparation, obtaining the maximum possible amount of biological material from forensic samples, and the following cell lysis, to create a simple standardized lysis protocol suitable for nearly all forensic material. After optimization and validation, the M-48 BioRobot((R)) workstation has been used for more than 20,000 routine lab samples. There has been no evidence of cross contamination. Resulting DNA from as small as three nuclear cells yield reliable complete STR amplification profiles. The DNA remains stable after 2 years of storage.
Hayes, Gillian R; Lee, Charlotte P; Dourish, Paul
2011-08-01
The purpose of this paper is to demonstrate how current visual representations of organizational and technological processes do not fully account for the variability present in everyday practices. We further demonstrate how narrative networks can augment these representations to indicate potential areas for successful or problematic adoption of new technologies and potential needs for additional training. We conducted a qualitative study of the processes and routines at a major academic medical center slated to be supported by the development and installation of a new comprehensive HIT system. We used qualitative data collection techniques including observations of the activities to be supported by the new system and interviews with department heads, researchers, and both clinical and non-clinical staff. We conducted a narrative network analysis of these data by choosing exemplar processes to be modeled, selecting and analyzing narrative fragments, and developing visual representations of the interconnection of these narratives. Narrative networks enable us to view the variety of ways work has been and can be performed in practice, influencing our ability to design for innovation in use. Narrative networks are a means for analyzing and visualizing organizational routines in concert with more traditional requirements engineering, workflow modeling, and quality improvement outcome measurement. This type of analysis can support a deeper and more nuanced understanding of how and why certain routines continue to exist, change, or stop entirely. At the same time, it can illuminate areas in which adoption may be slow, more training or communication may be needed, and routines preferred by the leadership are subverted by routines preferred by the staff. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Veinot, Tiffany C; Bosk, Emily A; Unnikrishnan, K P; Iwashyna, Theodore J
2012-11-01
Heart attack, or acute myocardial infarction (AMI), is a leading cause of death in the United States (U.S.). The most effective therapy for AMI is rapid revascularization: the mechanical opening of the clogged artery in the heart. Forty-four percent of patients with AMI who are admitted to a non-revascularization hospital in the U.S. are transferred to a hospital with that capacity. Yet, we know little about the process by which community hospitals complete these transfers, and why publicly available hospital quality data plays a small role in community hospitals' choice of transfer destinations. Therefore, we investigated how community hospital staff implement patient transfers and select destinations. We conducted a mixed methods study involving: interviews with staff at three community hospitals (n = 25) in a Midwestern state and analysis of U.S. national Medicare records for 1996-2006. Community hospitals in the U.S., including our field sites, typically had longstanding relationships with one key receiving hospital. Community hospitals addressed the need for rapid AMI patient transfers by routinizing the collective, interhospital work process. Routinization reduced staff uncertainty, coordinated their efforts and conserved their cognitive resources for patient care. While destination selection was nominally a physician role, the decision was routinized, such that staff immediately contacted a "usual" transfer destination upon AMI diagnosis. Transfer destination selection was primarily driven at an institutional level by organizational concerns and bed supply, rather than physician choice or patient preference. Transfer routinization emerged as a form of social order that invoked tradeoffs between process speed and efficiency and patient-centered, quality-driven decision making. We consider the implications of routinization and institutional imperatives for health policy, quality improvement and health informatics interventions. Copyright © 2012 Elsevier Ltd. All rights reserved.
Quantification of Protozoa and Viruses from Small Water Volumes
Bonilla, J. Alfredo; Bonilla, Tonya D.; Abdelzaher, Amir M.; Scott, Troy M.; Lukasik, Jerzy; Solo-Gabriele, Helena M.; Palmer, Carol J.
2015-01-01
Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The goals of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter) and viruses capture by charge (bottom filter). Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation—IFA-microscopy, while virus (poliovirus) detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45%) and poliovirus (67% vs. 55%) whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%). Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels. PMID:26114244
Quantification of Protozoa and Viruses from Small Water Volumes.
Bonilla, J Alfredo; Bonilla, Tonya D; Abdelzaher, Amir M; Scott, Troy M; Lukasik, Jerzy; Solo-Gabriele, Helena M; Palmer, Carol J
2015-06-24
Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The aims of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter) and viruses capture by charge (bottom filter). Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation-IFA-microscopy, while virus (poliovirus) detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45%) and poliovirus (67% vs. 55%) whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%). Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels.
Gnanou Besse, Nathalie; Favret, Sandra; Desreumaux, Jennifer; Decourseulles Brasseur, Emilie; Kalmokoff, Martin
2016-05-02
The EN ISO 11290-1 method for the isolation of Listeria monocytogenes from food is carried out using a double enrichment in Fraser broths. While the method is effective it is also quite long requiring 4-7 days to process a contaminated food, and may be adversely affected by inter-strain and/or inter-species competition in samples containing mixed Listeria populations. Currently, we have little information on the impact of competition on food testing under routine conditions. Food samples (n=130) were analyzed using the standard method and the evolution of Listeria populations in 89 naturally contaminated samples followed over the entire enrichment process. In most instances, maximum increase in L. monocytogenes population occurred over the first 24h following sub-culture in Full Fraser broth and strain recovery was similar at both 24 and 48 h, indicating that the second enrichment step can be reduced by 24h without impacting the recovery of L. monocytogenes or affecting the sensitivity of the method. In approximately 6% of naturally contaminated samples the presence of competing Listeria species adversely impacted L. monocytogenes population levels. Moreover, these effects were more pronounced during the latter 24h of the Fraser enrichment, and potentially could affect or complicate the isolation of these strains. Copyright © 2016 Elsevier B.V. All rights reserved.
[Saarland Growth Study: sampling design].
Danker-Hopfe, H; Zabransky, S
2000-01-01
The use of reference data to evaluate the physical development of children and adolescents is part of the daily routine in the paediatric ambulance. The construction of such reference data is based on the collection of extensive reference data. There are different kinds of reference data: cross sectional references, which are based on data collected from a big representative cross-sectional sample of the population, longitudinal references, which are based on follow-up surveys of usually smaller samples of individuals from birth to maturity, and mixed longitudinal references, which are a combination of longitudinal and cross-sectional reference data. The advantages and disadvantages of the different methods of data collection and the resulting reference data are discussed. The Saarland Growth Study was conducted for several reasons: growth processes are subject to secular changes, there are no specific reference data for children and adolescents from this part of the country and the growth charts in use in the paediatric praxis are possibly not appropriate any more. Therefore, the Saarland Growth Study served two purposes a) to create actual regional reference data and b) to create a database for future studies on secular trends in growth processes of children and adolescents from Saarland. The present contribution focusses on general remarks on the sampling design of (cross-sectional) growth surveys and its inferences for the design of the present study.
40 CFR 141.803 - Coliform sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... aircraft water system, the sampling frequency must be determined by the disinfection and flushing frequency... disinfection and flushing frequency recommended by the aircraft water system manufacturer, when available. Where the aircraft water system manufacturer does not specify a recommended routine disinfection and...
Mairinger, Fabian D; Vollbrecht, Claudia; Streubel, Anna; Roth, Andreas; Landt, Olfert; Walter, Henry F R; Kollmeier, Jens; Mairinger, Thomas
2014-01-01
Activating epidermal growth factor receptor (EGFR) gene mutations can be successfully treated by EGFR tyrosine kinase inhibitors (EGFR-TKIs), but nearly 50% of all patients' exhibit progression of the disease until treatment because of T790M mutations. It is proposed that this is mostly caused by therapy-resistant tumor clones harboring a T790M mutation. Until now no cost-effective routine-diagnostic method for EGFR-resistance mutation status analysis is available leaving long-time response to TKI treatment to chance. Unambiguous identification of T790M EGFR mutations is mandatory to optimize initial treatment strategies. Artificial EGFR T790M mutations and human wild-type gDNA were prepared in several dilution series. Preferential amplification using coamplification at lower denaturation temperature-PCR (COLD-PCR) of the mutant sequence and subsequent HybProbe melting curve detection or pyrosequencing were performed in comparison to normal processing. COLD-PCR-based amplification allowed the detection of 0.125% T790M mutant DNA in a background of wild-type DNA in comparison to 5% while normal processing. These results were reproducible. COLD-PCR is a powerful and cost-effective tool for routine diagnostic to detect underrepresented tumor clones in clinical samples. A diagnostic tool for unambiguous identification of T790M-mutated minor tumor clones is now available enabling optimized therapy.
Multi-analyte profiling of inflammatory mediators in COPD sputum--the effects of processing.
Pedersen, Frauke; Holz, Olaf; Lauer, Gereon; Quintini, Gianluca; Kiwull-Schöne, Heidrun; Kirsten, Anne-Marie; Magnussen, Helgo; Rabe, Klaus F; Goldmann, Torsten; Watz, Henrik
2015-02-01
Prior to using a new multi-analyte platform for the detection of markers in sputum it is advisable to assess whether sputum processing, especially mucus homogenization by dithiothreitol (DTT), affects the analysis. In this study we tested a novel Human Inflammation Multi Analyte Profiling® Kit (v1.0 Luminex platform; xMAP®). Induced sputum samples of 20 patients with stable COPD (mean FEV1, 59.2% pred.) were processed in parallel using standard processing (with DTT) and a more time consuming sputum dispersion method with phosphate buffered saline (PBS) only. A panel of 47 markers was analyzed in these sputum supernatants by the xMAP®. Twenty-five of 47 analytes have been detected in COPD sputum. Interestingly, 7 markers have been detected in sputum processed with DTT only, or significantly higher levels were observed following DTT treatment (VDBP, α-2-Macroglobulin, haptoglobin, α-1-antitrypsin, VCAM-1, and fibrinogen). However, standard DTT-processing resulted in lower detectable concentrations of ferritin, TIMP-1, MCP-1, MIP-1β, ICAM-1, and complement C3. The correlation between processing methods for the different markers indicates that DTT processing does not introduce a bias by affecting individual sputum samples differently. In conclusion, our data demonstrates that the Luminex-based xMAP® panel can be used for multi-analyte profiling of COPD sputum using the routinely applied method of sputum processing with DTT. However, researchers need to be aware that the absolute concentration of selected inflammatory markers can be affected by DTT. Copyright © 2014 Elsevier Ltd. All rights reserved.
Development and Validation of the Pediatric Diabetes Routines Questionnaire for Adolescents.
Pierce, Jessica S; Jordan, Sara S; Arnau, Randolph C
2018-04-06
This study describes the development and psychometric evaluation of an adolescent self-report version of the Pediatric Diabetes Routines Questionnaire (PDRQ:A), a measure of diabetes-specific routines for youth with type 1 diabetes, and further validation of the parent-version (PDRQ:P) in an adolescent sample. Participants included 120 parent-adolescent dyads (ages 12-17) and an additional 24 parents who completed measures of diabetes-specific adolescent routines, general adolescent routines, diabetes self-care, and family support of youth diabetes care. The PDRQ:P/A demonstrated good internal consistency, test-retest reliability, and parent-child agreement, and adequate validity coefficients. Confirmatory factor analysis supported a one-factor model. Promising results were obtained. The PDRQ:P/A is a clinically feasible parent- and self-report measure that can provide valuable information regarding how frequently adolescents engage in their diabetes management tasks in a consistent manner. Addition of an adolescent report format will enhance the utility of the measure for clinical and research use.
Maharjan, Bhagwan; Shrestha, Bhabana; Weirich, Alexandra; Stewart, Andrew; Kelly-Cirino, Cassandra D
2016-12-01
This preliminary study evaluated the transport reagent OMNIgene SPUTUM (OMS) in a real-world, resource-limited setting: a zonal hospital and national tuberculosis (TB) reference laboratory, Nepal. The objectives were to: (1) assess the performance of OMS for transporting sputum from peripheral sites without cold chain stabilization; and (2) compare with Nepal's standard of care (SOC) for Mycobacterium tuberculosis smear and culture diagnostics. Sixty sputa were manually split into a SOC sample (airline-couriered to the laboratory, conventional processing) and an OMS sample (OMS added at collection, no cold chain transport or processing). Smear microscopy and solid culture were performed. Transport was 0-8days. Forty-one samples (68%) were smear-positive using both methods. Of the OMS cultures, 37 (62%) were positive, 22 (36%) were negative, and one (2%) was contaminated. Corresponding SOC results were 32 (53%), 21 (35%), and seven (12%). OMS "rescued" six (i.e., missed using SOC) compared with one rescue using SOC. Of smear-positives, six SOC samples produced contaminated cultures whereas only one OMS sample was contaminated. OMS reduced culture contamination from 12% to 2%, and improved TB detection by 9%. The results suggest that OMS could perform well as a no cold chain, long-term transport solution for smear and culture testing. The findings provide a basis for larger feasibility studies. Copyright © 2016 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.
Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua
2014-05-01
The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.
Implementation of unsteady sampling procedures for the parallel direct simulation Monte Carlo method
NASA Astrophysics Data System (ADS)
Cave, H. M.; Tseng, K.-C.; Wu, J.-S.; Jermy, M. C.; Huang, J.-C.; Krumdieck, S. P.
2008-06-01
An unsteady sampling routine for a general parallel direct simulation Monte Carlo method called PDSC is introduced, allowing the simulation of time-dependent flow problems in the near continuum range. A post-processing procedure called DSMC rapid ensemble averaging method (DREAM) is developed to improve the statistical scatter in the results while minimising both memory and simulation time. This method builds an ensemble average of repeated runs over small number of sampling intervals prior to the sampling point of interest by restarting the flow using either a Maxwellian distribution based on macroscopic properties for near equilibrium flows (DREAM-I) or output instantaneous particle data obtained by the original unsteady sampling of PDSC for strongly non-equilibrium flows (DREAM-II). The method is validated by simulating shock tube flow and the development of simple Couette flow. Unsteady PDSC is found to accurately predict the flow field in both cases with significantly reduced run-times over single processor code and DREAM greatly reduces the statistical scatter in the results while maintaining accurate particle velocity distributions. Simulations are then conducted of two applications involving the interaction of shocks over wedges. The results of these simulations are compared to experimental data and simulations from the literature where there these are available. In general, it was found that 10 ensembled runs of DREAM processing could reduce the statistical uncertainty in the raw PDSC data by 2.5-3.3 times, based on the limited number of cases in the present study.
Short communication: occurrence of Arcobacter species in industrial dairy plants.
Serraino, A; Giacometti, F
2014-01-01
The present study investigated the presence of Arcobacter spp. in industrial dairy plants. Between February and September 2013, pasteurized milk used for cheesemaking, processing and cleaning water, cheese, and environmental samples from different plant sites, including surfaces in contact or not in contact with food, were sampled. A total of 126 samples were analyzed by the cultural method and isolates were identified by multiplex PCR. Arcobacter spp. were isolated from 22 of 75 environmental samples (29.3%): of them, 22.7% were surfaces in contact with food and 38.7% surfaces not in contact with food. A total of 135 Arcobacter spp. isolates were obtained; of these, 129 and 6 were identified as Arcobacter butzleri and Arcobacter cryaerophilus, respectively. All food processing water and pasteurized milk samples were negative for Arcobacter species. We were not able to determine the primary source of contamination, but the isolation of both A. butzleri and A. cryaerophilus in surfaces in contact with food before and during manufacturing suggests that Arcobacter spp. are not or are only partially affected by routine sanitizing procedures in the industrial dairy plants studied. The efficacy of sanitizing procedures should be evaluated and further studies are needed to determine whether certain Arcobacter strains persist for long periods of time in industrial dairy plants and whether they can survive in different types of cheese in cases of postprocessing contamination. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
van Kasteren, Yasmin; Bradford, Dana; Zhang, Qing; Karunanithi, Mohan; Ding, Hang
2017-06-13
An ongoing challenge for smart homes research for aging-in-place is how to make sense of the large amounts of data from in-home sensors to facilitate real-time monitoring and develop reliable alerts. The objective of our study was to explore the usefulness of a routine-based approach for making sense of smart home data for the elderly. Maximum variation sampling was used to select three cases for an in-depth mixed methods exploration of the daily routines of three elderly participants in a smart home trial using 180 days of power use and motion sensor data and longitudinal interview data. Sensor data accurately matched self-reported routines. By comparing daily movement data with personal routines, it was possible to identify changes in routine that signaled illness, recovery from bereavement, and gradual deterioration of sleep quality and daily movement. Interview and sensor data also identified changes in routine with variations in temperature and daylight hours. The findings demonstrated that a routine-based approach makes interpreting sensor data easy, intuitive, and transparent. They highlighted the importance of understanding and accounting for individual differences in preferences for routinization and the influence of the cyclical nature of daily routines, social or cultural rhythms, and seasonal changes in temperature and daylight hours when interpreting information based on sensor data. This research has demonstrated the usefulness of a routine-based approach for making sense of smart home data, which has furthered the understanding of the challenges that need to be addressed in order to make real-time monitoring and effective alerts a reality. ©Yasmin van Kasteren, Dana Bradford, Qing Zhang, Mohan Karunanithi, Hang Ding. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 13.06.2017.
van Kasteren, Yasmin; Bradford, Dana; Karunanithi, Mohan; Ding, Hang
2017-01-01
Background An ongoing challenge for smart homes research for aging-in-place is how to make sense of the large amounts of data from in-home sensors to facilitate real-time monitoring and develop reliable alerts. Objective The objective of our study was to explore the usefulness of a routine-based approach for making sense of smart home data for the elderly. Methods Maximum variation sampling was used to select three cases for an in-depth mixed methods exploration of the daily routines of three elderly participants in a smart home trial using 180 days of power use and motion sensor data and longitudinal interview data. Results Sensor data accurately matched self-reported routines. By comparing daily movement data with personal routines, it was possible to identify changes in routine that signaled illness, recovery from bereavement, and gradual deterioration of sleep quality and daily movement. Interview and sensor data also identified changes in routine with variations in temperature and daylight hours. Conclusions The findings demonstrated that a routine-based approach makes interpreting sensor data easy, intuitive, and transparent. They highlighted the importance of understanding and accounting for individual differences in preferences for routinization and the influence of the cyclical nature of daily routines, social or cultural rhythms, and seasonal changes in temperature and daylight hours when interpreting information based on sensor data. This research has demonstrated the usefulness of a routine-based approach for making sense of smart home data, which has furthered the understanding of the challenges that need to be addressed in order to make real-time monitoring and effective alerts a reality. PMID:28611014
Bedtime Routines for Young Children: A Dose-Dependent Association with Sleep Outcomes
Mindell, Jodi A.; Li, Albert M.; Sadeh, Avi; Kwon, Robert; Goh, Daniel Y.T.
2015-01-01
Background: Establishment of a consistent bedtime routine (the activities that occur right before lights out) is often recommended as part of healthy sleep habits. However, no studies have investigated the dose-dependent association of a bedtime routine with sleep outcomes, especially in young children for whom they are particularly recommended. Thus, the aim of this study was to examine the associations of a consistent bedtime routine with sleep outcomes in young children (ages 0 through 5 y) in a large global sample and assess whether there is a dose-dependent relationship between the frequency of a bedtime routine both concurrently and retrospectively with sleep outcomes. Participants: Mothers of 10,085 children (Australia-New Zealand, Canada, China, Hong Kong, India, Japan, Korea, Malaysia, Philippines, Singapore, Thailand, United Kingdom, United States) completed the Brief Infant/Child Sleep Questionnaire. Results: A consistent bedtime routine was associated with better sleep outcomes, including earlier bedtimes, shorter sleep onset latency, reduced night wakings, and increased sleep duration. Decreased parent-perceived sleep problems and daytime behavior problems were also related to institution of a regular bedtime routine. Furthermore, there was a dose-dependent relationship, with better outcomes associated with increased “doses” of having a bedtime routine, both currently and retrospectively, and was found within both predominantly Asian and predominantly Caucasian cultural regions. Conclusions: These results indicate that having a regular nightly bedtime routine is associated with improved sleep in young children, and suggests that the more consistently a bedtime routine is instituted and the younger started the better. Citation: Mindell JA, Li AM, Sadeh A, Kwon R, Goh DY. Bedtime routines for young children: a dose-dependent association with sleep outcomes. SLEEP 2015;38(5):717–722. PMID:25325483
NASA Astrophysics Data System (ADS)
Annas, Suwardi; Djadir; Mutmainna Hasma, Sitti
2018-01-01
on is an activity to organize a mathematical concept that has been previously owned into a new mathematical structure. Activites in abstraction are recognizing, organizing and constructing. Recognizing is a process of identifying a mathematical structure that had existed before. Organizing is a process of using structural knowledge to be assembled into a solution of a problem and constructing is a process of organizing the characteristics of the object into a new structure that does not exist. In abstraction process, the students use attributes to address the object, including routine attribute, nonroutine attributes, and meaningless attributes. This research applied descriptive qualitative research which aimed to describe the abstraction ability of students from high, moderate, and low groups to construct a relation within triangle. In collecting the data, this research used students’ pre-ability math test, abstraction test, and guided interview. The sampling technique in this research was based on the students’ scores in pre-ability math test, which were divided into three groups. Two students from each group were opted as the subjects of this research. Questions of the test are based on the indicators of steps in abstraction activity. Thus, based on the data gained in this research, researcher determined the tendency of attributes used in each abstraction activity. The result of this research revealed that students from high, moderate and low groups were prone to use routine attributes in recognizing triangles. In organizing the characteristics within triangles, high group tended to organize the triangle correctly, while the moderate and low groups tended to organize the triangle incorrectly. In constructing relation within triangles, students in high, moderate and low groups construct it incompletely.
Isolation of animal viruses from farm livestock waste, soil and water.
Derbyshire, J. B.; Brown, E. G.
1978-01-01
Ten porcine enteroviruses, 2 porcine adenoviruses and 1 coronavirus were isolated directly from 32 samples of slurry collected from a pig fattening house. Concentration of the same samples by adsorption with the polyelectrolyte PE-60 yielded 24 porcine enteroviruses and 3 porcine adenoviruses. A porcine enterovirus was isolated, following PE-60 concentration, from 1 to 6 slurry samples from a sow farrowing house. No virus was isolated from 12 samples of slurry from dairy cows nor from 6 slurry samples from a calf-rearing unit. A porcine enterovirus was isolated from soil samples, after concentration with PE-60, collected 1, 2 and 8 days after pig slurry was spread on hay stubble. Two porcine enteroviruses were isolated by membrane filtration from 26 samples of surface run-off from land on which pig slurry was routinely spread, and 2 bovine enteroviruses were isolated from cattle feedlot run-off after adsorption to layers of talc and celite followed by hydroextraction. A porcine enterovirus was also isolated from 1 of 33 samples of surface water collected on farms on which pig slurry was routinely spread on the land, but no virus was isolated from 36 samples of ground water from the same farms. The surface water and ground water samples were concentrated by talc-celite adsorption and hydroextraction. PMID:100551
[Laser microdissection for biology and medicine].
Podgornyĭ, O V; Lazarev, V N; Govorun, V M
2012-01-01
For routine extraction of DNA, RNA, proteins and metabolites, small tissue pieces are placed into lysing solution. These tissue pieces in general contain different cell types. For this reason, lysate contains components of different cell types, which complicates the interpretation of molecular analysis results. The laser microdissection allows overcoming this trouble. The laser microdissection is a method to procure tissue samples contained defined cell subpopulations, individual cells and even subsellular components under direct microscopic visualization. Collected samples can be undergone to different downstream molecular assays: DNA analysis, RNA transcript profiling, cDNA library generation and gene expression analysis, proteomic analysis and metabolite profiling. The laser microdissection has wide applications in oncology (research and routine), cellular and molecular biology, biochemistry and forensics. This paper reviews the principles of different laser microdissection instruments, examples of laser microdissection application and problems of sample preparation for laser microdissection.
Sequim Marine Research Laboratory routine environmental measurements during CY-1976
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fix, J.J.; Blumer, P.J.
1977-05-01
Beginning in 1976, a routine environmental program was established at the Marine Research Laboratory (MRL) at Sequim, Washington. The program is designed, primarily, to determine levels of radioactivity present in selected biota in Sequim Bay. The biota were selected because of their presence near the laboratory and their capacity to concentrate trace elements. Other samples were obtained to determine the radionuclides in Sequim Bay and laboratory drinking water, as well as the ambient radiation exposure levels and surface deposition of fallout radionuclides for the laboratory area. A summary of the analytical methods used is included. The present document includes datamore » obtained during CY 1976, the first year of the program. Radionuclides present in samples are attributed to fallout. Data are included on content of oil and Cu in seawater samples.« less
Rao, Danish Ahmed; Aman, Aiysha; Muhammad Mubeen, Syed; Shah, Ahmed
2017-07-01
Stethoscopes routinely used for clinical examination of patients may potentially transfer micro-organisms and cause iatrogenic infections. This study was undertaken to detect the presence of microorganisms on stethoscopes used clinically in hospitals of Karachi, Pakistan and to ascertain the infection control practices of healthcare workers (HCWs). In a cross-sectional study, 118 samples were collected from public and private institutions. Samples were tested for the presence and sensitivity of pathogenic microorganisms. Microorganisms were found on diaphragms of 33/64 (51.6%) and 19/57 (33.3%) stethoscopes in public and private sector hospitals, respectively. Methycillin resistance was identified in all staphylococcally contaminated samples. Only 33 (18%) respondents reported cleaning their stethoscopes regularly. We highlight the need for more and better on-the-job routines for decontaminating stethoscopes among HCWs in Karachi.
Bacterial and fungal DNA extraction from blood samples: automated protocols.
Lorenz, Michael G; Disqué, Claudia; Mühl, Helge
2015-01-01
Automation in DNA isolation is a necessity for routine practice employing molecular diagnosis of infectious agents. To this end, the development of automated systems for the molecular diagnosis of microorganisms directly in blood samples is at its beginning. Important characteristics of systems demanded for routine use include high recovery of microbial DNA, DNA-free containment for the reduction of DNA contamination from exogenous sources, DNA-free reagents and consumables, ideally a walkaway system, and economical pricing of the equipment and consumables. Such full automation of DNA extraction evaluated and in use for sepsis diagnostics is yet not available. Here, we present protocols for the semiautomated isolation of microbial DNA from blood culture and low- and high-volume blood samples. The protocols include a manual pretreatment step followed by automated extraction and purification of microbial DNA.
NASA Astrophysics Data System (ADS)
Li, Yutong; Wang, Yuxin; Duffy, Alex H. B.
2014-11-01
Computer-based conceptual design for routine design has made great strides, yet non-routine design has not been given due attention, and it is still poorly automated. Considering that the function-behavior-structure(FBS) model is widely used for modeling the conceptual design process, a computer-based creativity enhanced conceptual design model(CECD) for non-routine design of mechanical systems is presented. In the model, the leaf functions in the FBS model are decomposed into and represented with fine-grain basic operation actions(BOA), and the corresponding BOA set in the function domain is then constructed. Choosing building blocks from the database, and expressing their multiple functions with BOAs, the BOA set in the structure domain is formed. Through rule-based dynamic partition of the BOA set in the function domain, many variants of regenerated functional schemes are generated. For enhancing the capability to introduce new design variables into the conceptual design process, and dig out more innovative physical structure schemes, the indirect function-structure matching strategy based on reconstructing the combined structure schemes is adopted. By adjusting the tightness of the partition rules and the granularity of the divided BOA subsets, and making full use of the main function and secondary functions of each basic structure in the process of reconstructing of the physical structures, new design variables and variants are introduced into the physical structure scheme reconstructing process, and a great number of simpler physical structure schemes to accomplish the overall function organically are figured out. The creativity enhanced conceptual design model presented has a dominant capability in introducing new deign variables in function domain and digging out simpler physical structures to accomplish the overall function, therefore it can be utilized to solve non-routine conceptual design problem.
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.
Improved method of producing satisfactory sections of whole eyeball by routine histology.
Arko-Boham, Benjamin; Ahenkorah, John; Hottor, Bismarck Afedo; Dennis, Esther; Addai, Frederick Kwaku
2014-02-01
To overcome the loss of structural integrity when eyeball sections are prepared by wax embedding, we experimentally modified the routine histological procedure and report satisfactorily well-preserved antero-posterior sections of whole eyeballs for teaching/learning purposes. Presently histological sections of whole eyeballs are not readily available because substantial structural distortions attributable to variable consistency of tissue components (and their undesired differential shrinkage) result from routine processing. Notably, at the dehydration stage of processing, the soft, gel-like vitreous humor considerably shrinks relative to the tough fibrous sclera causing collapse of the ocular globe. Additionally, the combined effects of fixation, dehydration, and embedding at 60°C renders the eye lens too hard for microtome slicing at thicknesses suitable for light microscopy. We satisfactorily preserved intact antero-posterior sections of eyeballs via routine paraffin wax processing procedure entailing two main modifications; (i) careful needle aspiration of vitreous humor and replacement with molten wax prior to wax infiltration; (ii) softening of lens in trimmed wax block by placing a drop of concentrated liquid phenol on it for 3 h during microtomy. These variations of the routine histological method produced intact whole eyeball sections with retinal detachment as the only structural distortion. Intact sections of the eyeball obtained compares well with the laborious, expensive, and 8-week long celloidin method. Our method has wider potential usability than costly freeze drying method which requires special skills and equipment (cryotome) and does not produce whole eyeball sections. Copyright © 2013 Wiley Periodicals, Inc.
Weir, Natalie M; Newham, Rosemary; Corcoran, Emma D; Ali Atallah Al-Gethami, Ashwag; Mohammed Abd Alridha, Ali; Bowie, Paul; Watson, Anne; Bennie, Marion
2017-11-21
The Scottish Patient Safety Programme - Pharmacy in Primary Care collaborative is a quality improvement initiative adopting the Institute of Healthcare Improvement Breakthrough Series collaborative approach. The programme developed and piloted High Risk Medicine (HRM) Care Bundles (CB), focused on warfarin and non-steroidal anti-inflammatories (NSAIDs), within 27 community pharmacies over 4 NHS Regions. Each CB involves clinical assessment and patient education, although the CB content varies between regions. To support national implementation, this study aims to understand how the pilot pharmacies integrated the HRM CBs into routine practice to inform the development of a generic HRM CB process map. Regional process maps were developed in 4 pharmacies through simulation of the CB process, staff interviews and documentation of resources. Commonalities were collated to develop a process map for each HRM, which were used to explore variation at a national event. A single, generic process map was developed which underwent validation by case study testing. The findings allowed development of a generic process map applicable to warfarin and NSAID CB implementation. Five steps were identified as required for successful CB delivery: patient identification; clinical assessment; pharmacy CB prompt; CB delivery; and documentation. The generic HRM CB process map encompasses the staff and patients' journey and the CB's integration into routine community pharmacy practice. Pharmacist involvement was required only for clinical assessment, indicating suitability for whole-team involvement. Understanding CB integration into routine practice has positive implications for successful implementation. The generic process map can be used to develop targeted resources, and/or be disseminated to facilitate CB delivery and foster whole team involvement. Similar methods could be utilised within other settings, to allow those developing novel services to distil the key processes and consider their integration within routine workflows to effect maximal, efficient implementation and benefit to patient care. Copyright © 2017 Elsevier Inc. All rights reserved.
Sputum color: potential implications for clinical practice.
Johnson, Allen L; Hampson, David F; Hampson, Neil B
2008-04-01
Respiratory infections with sputum production are a major reason for physician visits, diagnostic testing, and antibiotic prescription in the United States. We sought to determine whether the simple characteristic of sputum color provides information that impacts resource utilization such as laboratory testing and prescription of antibiotics. Out-patient sputum samples submitted to the microbiology laboratory for routine analysis were assigned to one of 8 color categories (green, yellow-green, rust, yellow, red, cream, white, and clear), based on a key made from paint chip color samples. Subsequent Gram stain and culture results were compared to sputum color. Of 289 consecutive samples, 144 (50%) met standard Gram-stain criteria for being acceptable lower-respiratory-tract specimens. In the acceptable Gram-stain group, 60 samples had a predominant organism on Gram stain, and the culture yielded a consistent result in 42 samples (15% of the 289 total specimens). Yield at each level of analysis differed greatly by color. The yield from sputum colors green, yellow-green, yellow, and rust was much higher than the yield from cream, white, or clear. If out-patient sputum is cream, white, or clear, the yield from bacteriologic analysis is extremely low. This information can reduce laboratory processing costs and help minimize unnecessary antibiotic prescription.
Salem, Shady; Chang, Sam S; Clark, Peter E; Davis, Rodney; Herrell, S Duke; Kordan, Yakup; Wills, Marcia L; Shappell, Scott B; Baumgartner, Roxelyn; Phillips, Sharon; Smith, Joseph A; Cookson, Michael S; Barocas, Daniel A
2010-10-01
Whole mount processing is more resource intensive than routine systematic sampling of radical retropubic prostatectomy specimens. We compared whole mount and systematic sampling for detecting pathological outcomes, and compared the prognostic value of pathological findings across pathological methods. We included men (608 whole mount and 525 systematic sampling samples) with no prior treatment who underwent radical retropubic prostatectomy at Vanderbilt University Medical Center between January 2000 and June 2008. We used univariate and multivariate analysis to compare the pathological outcome detection rate between pathological methods. Kaplan-Meier curves and the log rank test were used to compare the prognostic value of pathological findings across pathological methods. There were no significant differences between the whole mount and the systematic sampling groups in detecting extraprostatic extension (25% vs 30%), positive surgical margins (31% vs 31%), pathological Gleason score less than 7 (49% vs 43%), 7 (39% vs 43%) or greater than 7 (12% vs 13%), seminal vesicle invasion (8% vs 10%) or lymph node involvement (3% vs 5%). Tumor volume was higher in the systematic sampling group and whole mount detected more multiple surgical margins (each p <0.01). There were no significant differences in the likelihood of biochemical recurrence between the pathological methods when patients were stratified by pathological outcome. Except for estimated tumor volume and multiple margins whole mount and systematic sampling yield similar pathological information. Each method stratifies patients into comparable risk groups for biochemical recurrence. Thus, while whole mount is more resource intensive, it does not appear to result in improved detection of clinically important pathological outcomes or prognostication. Copyright © 2010 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hallett, B. W.; Dere, A. L. D.; Lehnert, K.; Carter, M.
2016-12-01
Vast numbers of physical samples are routinely collected by geoscientists to probe key scientific questions related to global climate change, biogeochemical cycles, magmatic processes, mantle dynamics, etc. Despite their value as irreplaceable records of nature the majority of these samples remain undiscoverable by the broader scientific community because they lack a digital presence or are not well-documented enough to facilitate their discovery and reuse for future scientific and educational use. The NSF EarthCube iSamples Research Coordination Network seeks to develop a unified approach across all Earth Science disciplines for the registration, description, identification, and citation of physical specimens in order to take advantage of the new opportunities that cyberinfrastructure offers. Even as consensus around best practices begins to emerge, such as the use of the International Geo Sample Number (IGSN), more work is needed to communicate these practices to investigators to encourage widespread adoption. Recognizing the importance of students and early career scientists in particular to transforming data and sample management practices, the iSamples Education and Training Working Group is developing training modules for sample collection, documentation, and management workflows. These training materials are made available to educators/research supervisors online at http://earthcube.org/group/isamples and can be modularized for supervisors to create a customized research workflow. This study details the design and development of several sample management tutorials, created by early career scientists and documented in collaboration with undergraduate research students in field and lab settings. Modules under development focus on rock outcrops, rock cores, soil cores, and coral samples, with an emphasis on sample management throughout the collection, analysis and archiving process. We invite others to share their sample management/registration workflows and to develop training modules. This educational approach, with evolving digital materials, can help prepare future scientists to perform research in a way that will contribute to EarthCube data integration and discovery.
Latysh, Natalie E.; Wetherbee, Gregory A.
2007-01-01
The U.S. Geological Survey (USGS) Branch of Quality Systems operates external quality assurance programs for the National Atmospheric Deposition Program/Mercury Deposition Network (NADP/MDN). Beginning in 2004, three programs have been implemented: the system blank program, the interlaboratory comparison program, and the blind audit program. Each program was designed to measure error contributed by specific components in the data-collection process. The system blank program assesses contamination that may result from sampling equipment, field exposure, and routine handling and processing of the wet-deposition samples. The interlaboratory comparison program evaluates bias and precision of analytical results produced by the Mercury Analytical Laboratory (HAL) for the NADP/MDN, operated by Frontier GeoSciences, Inc. The HAL's performance is compared with the performance of five other laboratories. The blind audit program assesses bias and variability of MDN data produced by the HAL using solutions disguised as environmental samples to ascertain true laboratory performance. This report documents the implementation of quality assurance procedures for the NADP/MDN and the operating procedures for each of the external quality assurance programs conducted by the USGS. The USGS quality assurance information provides a measure of confidence to NADP/MDN data users that measurement variability is distinguished from environmental signals.
Validity of Computer Adaptive Tests of Daily Routines for Youth with Spinal Cord Injury
Haley, Stephen M.
2013-01-01
Objective: To evaluate the accuracy of computer adaptive tests (CATs) of daily routines for child- and parent-reported outcomes following pediatric spinal cord injury (SCI) and to evaluate the validity of the scales. Methods: One hundred ninety-six daily routine items were administered to 381 youths and 322 parents. Pearson correlations, intraclass correlation coefficients (ICC), and 95% confidence intervals (CI) were calculated to evaluate the accuracy of simulated 5-item, 10-item, and 15-item CATs against the full-item banks and to evaluate concurrent validity. Independent samples t tests and analysis of variance were used to evaluate the ability of the daily routine scales to discriminate between children with tetraplegia and paraplegia and among 5 motor groups. Results: ICC and 95% CI demonstrated that simulated 5-, 10-, and 15-item CATs accurately represented the full-item banks for both child- and parent-report scales. The daily routine scales demonstrated discriminative validity, except between 2 motor groups of children with paraplegia. Concurrent validity of the daily routine scales was demonstrated through significant relationships with the FIM scores. Conclusion: Child- and parent-reported outcomes of daily routines can be obtained using CATs with the same relative precision of a full-item bank. Five-item, 10-item, and 15-item CATs have discriminative and concurrent validity. PMID:23671380
Barton, Christopher; Proudfoot, Judith; Amoroso, Cheryl; Ramsay, Emmae; Holton, Christine; Bubner, Tanya; Harris, Mark; Beilby, Justin
2009-06-01
We investigated the quality of primary care asthma management in a sample of Australian general practices. 247 general practitioners (GPs) from 97 practices completed a structured interview about management of asthma, diabetes and hypertension/heart disease. A further structured interview with the senior practice principal and practice manager was used to collect information about practice capacity for chronic disease management. Just under half of GPs (47%) had access to an asthma register and the majority (76%) had access to spirometry in their practice. In terms of routine management of asthma, 12% of GPs reported using spirometry routinely, 13% routinely reviewed written asthma action plans, 27% routinely provided education about trigger factors, 30% routinely reviewed inhaler technique, 24% routinely assessed asthma severity, and 29% routinely assessed physical activity. Practice characteristics such as practice size (p=1.0) and locality (rural/metropolitan) (p=0.7) did not predict quality of asthma management nor did indicators of practice capacity including Business maturity, IT/IM maturity, Multidisciplinary teamwork, and Clinical linkages. Gaps remain in the provision of evidence-based care for patients with asthma in general practice. Markers of practice capacity measured here were not associated with guideline-based respiratory care within practices.
Authenticated DNA from Ancient Wood Remains
LIEPELT, SASCHA; SPERISEN, CHRISTOPH; DEGUILLOUX, MARIE-FRANCE; PETIT, REMY J.; KISSLING, ROY; SPENCER, MATTHEW; DE BEAULIEU, JACQUES-LOUIS; TABERLET, PIERRE; GIELLY, LUDOVIC; ZIEGENHAGEN, BIRGIT
2006-01-01
• Background The reconstruction of biological processes and human activities during the last glacial cycle relies mainly on data from biological remains. Highly abundant tissues, such as wood, are candidates for a genetic analysis of past populations. While well-authenticated DNA has now been recovered from various fossil remains, the final ‘proof’ is still missing for wood, despite some promising studies. • Scope The goal of this study was to determine if ancient wood can be analysed routinely in studies of archaeology and palaeogenetics. An experiment was designed which included blind testing, independent replicates, extensive contamination controls and rigorous statistical tests. Ten samples of ancient wood from major European forest tree genera were analysed with plastid DNA markers. • Conclusions Authentic DNA was retrieved from wood samples up to 1000 years of age. A new tool for real-time vegetation history and archaeology is ready to use. PMID:16987920
Optimization and automation of quantitative NMR data extraction.
Bernstein, Michael A; Sýkora, Stan; Peng, Chen; Barba, Agustín; Cobas, Carlos
2013-06-18
NMR is routinely used to quantitate chemical species. The necessary experimental procedures to acquire quantitative data are well-known, but relatively little attention has been applied to data processing and analysis. We describe here a robust expert system that can be used to automatically choose the best signals in a sample for overall concentration determination and determine analyte concentration using all accepted methods. The algorithm is based on the complete deconvolution of the spectrum which makes it tolerant of cases where signals are very close to one another and includes robust methods for the automatic classification of NMR resonances and molecule-to-spectrum multiplets assignments. With the functionality in place and optimized, it is then a relatively simple matter to apply the same workflow to data in a fully automatic way. The procedure is desirable for both its inherent performance and applicability to NMR data acquired for very large sample sets.
Assavasilavasukul, Prapakorn; Lau, Boris L T; Harrington, Gregory W; Hoffman, Rebecca M; Borchardt, Mark A
2008-05-01
The presence of waterborne enteric pathogens in municipal water supplies contributes risk to public health. To evaluate the removal of these pathogens in drinking water treatment processes, previous researchers have spiked raw waters with up to 10(6) pathogens/L in order to reliably detect the pathogens in treated water. These spike doses are 6-8 orders of magnitude higher than pathogen concentrations routinely observed in practice. In the present study, experiments were conducted with different sampling methods (i.e., grab versus continuous sampling) and initial pathogen concentrations ranging from 10(1) to 10(6) pathogens/L. Results showed that Cryptosporidium oocyst and Giardia cyst removal across conventional treatment were dependent on initial pathogen concentrations, with lower pathogen removals observed when lower initial pathogen spike doses were used. In addition, higher raw water turbidity appeared to result in higher log removal for both Cryptosporidium oocysts and Giardia cysts.
Hurtado, I; Aboal, M; Zafra, E; Campillo, D
2008-02-01
The study of the dynamics of phytobenthic and phytoplankton communities was undertaken, during a year, in the regulation reservoir associated with a water treatment plant (WTP), which provides the city of Murcia (Spain) with drinking water. Water samples were collected in different stages of the treatment. In the reservoir, the presence of dissolved and intracellular microcystins is constant, both in benthos and in plankton. The collected samples show a positive correlation between the dissolved microcystins and the benthic ones in the reservoir itself, as well as in an upstream reservoir (Ojós Reservoir). The treatment process (ozone+clarification+ozone+activated carbon) is very effective in the removal of toxins, and the drinking water produced is totally free of microcystins. The incorporation of the benthic communities in the routine check for the presence of microcystins is recommended, since it is not compulsory according to the current legislation.
Amezcua, Carlos A; Szabo, Christina M
2013-06-01
In this work, we applied nuclear magnetic resonance (NMR) spectroscopy to rapidly assess higher order structure (HOS) comparability in protein samples. Using a variation of the NMR fingerprinting approach described by Panjwani et al. [2010. J Pharm Sci 99(8):3334-3342], three nonglycosylated proteins spanning a molecular weight range of 6.5-67 kDa were analyzed. A simple statistical method termed easy comparability of HOS by NMR (ECHOS-NMR) was developed. In this method, HOS similarity between two samples is measured via the correlation coefficient derived from linear regression analysis of binned NMR spectra. Applications of this method include HOS comparability assessment during new product development, manufacturing process changes, supplier changes, next-generation products, and the development of biosimilars to name just a few. We foresee ECHOS-NMR becoming a routine technique applied to comparability exercises used to complement data from other analytical techniques. Copyright © 2013 Wiley Periodicals, Inc.
Yamaguti, M.; Muller, E.E.; Piffer, A.I.; Kich, J.D.; Klein, C.S.; Kuchiishi, S.S.
2008-01-01
Since Mycoplasma hyopneumoniae isolation in appropriate media is a difficult task and impractical for daily routine diagnostics, Nested-PCR (N-PCR) techniques are currently used to improve the direct diagnostic sensitivity of Swine Enzootic Pneumonia. In a first experiment, this paper describes a N-PCR technique optimization based on three variables: different sampling sites, sample transport media, and DNA extraction methods, using eight pigs. Based on the optimization results, a second experiment was conducted for testing validity using 40 animals. In conclusion, the obtained results of the N-PCR optimization and validation allow us to recommend this test as a routine monitoring diagnostic method for Mycoplasma hyopneumoniae infection in swine herds. PMID:24031248
Roisin, S; Huang, T-D; de Mendonça, R; Nonhoff, C; Bogaerts, P; Hites, M; Delaere, B; Hamels, S; de Longueville, F; Glupczynski, Y; Denis, O
2018-01-01
The purpose of this study was evaluation of the VAPChip assay based on the "Rapid-Array-PCR-technology" which targets 13 respiratory pathogens and 24 β-lactam resistance genes directly on respiratory clinical specimens. The first step included analysis of 45 respiratory specimens in order to calibrate and determine the threshold for target genes. The second prospective step involved 85 respiratory samples from patients suspected of nosocomial pneumonia collected in two academic hospitals over an 8-month period. Results of the VAPChip assay were compared to routine methods. The first step showed a large proportion of positive signals for H. influenzae and/or S. pneumoniae. For identification, discrepancies were observed in seven samples. Thresholds were adapted and two probes were re-designed to create a new version of the cartridge. In the second phase, sensitivity and specificity of the VAPchip for bacterial identification were 72.9% and 99.1%, respectively. Seventy (82%) pathogens were correctly identified by both methods. Nine pathogens detected by the VAPChip were culture negative and 26 pathogens identified by culture were VAPChip negative. For resistance mechanisms, 11 probes were positive without identification of pathogens with an antimicrobial-susceptibility testing compatible by culture. However, the patient's recent microbiological history was able to explain most of these positive signals. The VAPChip assay simultaneously detects different pathogens and resistance mechanisms directly from clinical samples. This system seems very promising but the extraction process needs to be automated for routine implementation. This kind of rapid point-of-care automated platform permitting a syndromic approach will be the future challenge in the management of infectious diseases.
NASA Astrophysics Data System (ADS)
Cécillon, Lauric; Quénéa, Katell; Anquetil, Christelle; Barré, Pierre
2015-04-01
Due to its large heterogeneity at all scales (from soil core to the globe), several measurements are often mandatory to get a meaningful value of a measured soil property. A large number of measurements can therefore be needed to study a soil property whatever the scale of the study. Moreover, several soil investigation techniques produce large and complex datasets, such as pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) which produces complex 3-way data. In this context, straightforward methods designed to speed up data treatments are needed to deal with large datasets. GC-MS pyrolysis (py-GCMS) is a powerful and frequently used tool to characterize soil organic matter (SOM). However, the treatment of the results of a py-GCMS analysis of soil sample is time consuming (number of peaks, co-elution, etc.) and the treatment of large data set of py-GCMS results is rather laborious. Moreover, peak position shifts and baseline drifts between analyses make the automation of GCMS programs data treatment difficult. These problems can be fixed using the Parallel Factor Analysis 2 (PARAFAC 2, Kiers et al., 1999; Bro et al., 1999). This algorithm has been applied frequently on chromatography data but has never been applied to analyses of SOM. We developed a Matlab routine based on existing Matlab packages dedicated to the simultaneous treatment of dozens of pyro-chromatograms mass spectra. We applied this routine on 40 soil samples. The benefits and expected improvements of our method will be discussed in our poster. References Kiers et al. (1999) PARAFAC2 - PartI. A direct fitting algorithm for the PARAFAC2 model. Journal of Chemometrics, 13: 275-294. Bro et al. (1999) PARAFAC2 - PartII. Modeling chromatographic data with retention time shifts. Journal of Chemometrics, 13: 295-309.
Integrated sample-to-detection chip for nucleic acid test assays.
Prakash, R; Pabbaraju, K; Wong, S; Tellier, R; Kaler, K V I S
2016-06-01
Nucleic acid based diagnostic techniques are routinely used for the detection of infectious agents. Most of these assays rely on nucleic acid extraction platforms for the extraction and purification of nucleic acids and a separate real-time PCR platform for quantitative nucleic acid amplification tests (NATs). Several microfluidic lab on chip (LOC) technologies have been developed, where mechanical and chemical methods are used for the extraction and purification of nucleic acids. Microfluidic technologies have also been effectively utilized for chip based real-time PCR assays. However, there are few examples of microfluidic systems which have successfully integrated these two key processes. In this study, we have implemented an electro-actuation based LOC micro-device that leverages multi-frequency actuation of samples and reagents droplets for chip based nucleic acid extraction and real-time, reverse transcription (RT) PCR (qRT-PCR) amplification from clinical samples. Our prototype micro-device combines chemical lysis with electric field assisted isolation of nucleic acid in a four channel parallel processing scheme. Furthermore, a four channel parallel qRT-PCR amplification and detection assay is integrated to deliver the sample-to-detection NAT chip. The NAT chip combines dielectrophoresis and electrostatic/electrowetting actuation methods with resistive micro-heaters and temperature sensors to perform chip based integrated NATs. The two chip modules have been validated using different panels of clinical samples and their performance compared with standard platforms. This study has established that our integrated NAT chip system has a sensitivity and specificity comparable to that of the standard platforms while providing up to 10 fold reduction in sample/reagent volumes.
Nardi, Valentina; Pulluqi, Olja; Abramson, Jeremy S; Dal Cin, Paola; Hasserjian, Robert P
2015-06-01
Bone marrow (BM) evaluation is an important part of lymphoma staging, which guides patient management. Although positive staging marrow is defined as morphologically identifiable disease, such samples often also include flow cytometric analysis and conventional karyotyping. Cytogenetic analysis is a labor-intensive and costly procedure and its utility in this setting is uncertain. We retrospectively reviewed pathological reports of 526 staging marrow specimens in which conventional karyotyping had been performed. All samples originated from a single institution from patients with previously untreated Hodgkin and non-Hodgkin lymphomas presenting in an extramedullary site. Cytogenetic analysis revealed clonal abnormalities in only eight marrow samples (1.5%), all of which were positive for lymphoma by morphologic evaluation. Flow cytometry showed a small clonal lymphoid population in three of the 443 morphologically negative marrow samples (0.7%). Conventional karyotyping is rarely positive in lymphoma staging marrow samples and, in our cohort, the BM karyotype did not contribute clinically relevant information in the vast majority of cases. Our findings suggest that karyotyping should not be performed routinely on BM samples taken to stage previously diagnosed extramedullary lymphomas unless there is pathological evidence of BM involvement by lymphoma. © 2015 Wiley Periodicals, Inc.
Anis, Eman; Hawkins, Ian K; Ilha, Marcia R S; Woldemeskel, Moges W; Saliki, Jeremiah T; Wilkes, Rebecca P
2018-07-01
The laboratory diagnosis of infectious diseases, especially those caused by mixed infections, is challenging. Routinely, it requires submission of multiple samples to separate laboratories. Advances in next-generation sequencing (NGS) have provided the opportunity for development of a comprehensive method to identify infectious agents. This study describes the use of target-specific primers for PCR-mediated amplification with the NGS technology in which pathogen genomic regions of interest are enriched and selectively sequenced from clinical samples. In the study, 198 primers were designed to target 43 common bovine and small-ruminant bacterial, fungal, viral, and parasitic pathogens, and a bioinformatics tool was specifically constructed for the detection of targeted pathogens. The primers were confirmed to detect the intended pathogens by testing reference strains and isolates. The method was then validated using 60 clinical samples (including tissues, feces, and milk) that were also tested with other routine diagnostic techniques. The detection limits of the targeted NGS method were evaluated using 10 representative pathogens that were also tested by quantitative PCR (qPCR), and the NGS method was able to detect the organisms from samples with qPCR threshold cycle ( C T ) values in the 30s. The method was successful for the detection of multiple pathogens in the clinical samples, including some additional pathogens missed by the routine techniques because the specific tests needed for the particular organisms were not performed. The results demonstrate the feasibility of the approach and indicate that it is possible to incorporate NGS as a diagnostic tool in a cost-effective manner into a veterinary diagnostic laboratory. Copyright © 2018 Anis et al.
Barret, Laurie-Anne; Polidori, Ange; Bonneté, Françoise; Bernard-Savary, Pierre; Jungas, Colette
2013-03-15
The hydrophobic nature of membrane proteins (MPs) necessitates the use of detergents for their extraction, solubilization and purification. Because the concentration of amphiphiles is crucial in the crystallization process, detergent quantification is essential to routine analysis. Here we describe a quantitative high-performance thin-layer chromatography (HPTLC) method we developed for the detection of small quantities of detergent bound to solubilized MPs. After optimization of aqueous deposit conditions, we show that most detergents widely used in membrane protein crystallography display distinctive mobilities in a mixture of dichloromethane, methanol and acetic acid 32:7.6:0.4 (v/v/v). Migration and derivatization conditions were optimized with n-dodecyl-β-D-maltoside (DDM), the most popular detergent for membrane protein crystallization. A linear calibration curve very well fits our data from 0.1 to 1.6 μg of DDM in water with a limit of detection of 0.05 μg. This limit of detection is the best achieved to date for a routine detergent assay, being not modified by the addition of NaCl, commonly used in protein buffers. With these chromatographic conditions, no prior treatment is required to assess the quantities of detergent bound to purified MPs, thus enabling the quantification of close structure detergents via a single procedure. This HPTLC method, which is fast and requires low sample volume, is fully suitable for routine measurements. Copyright © 2013 Elsevier B.V. All rights reserved.
Lommen, Arjen; van der Kamp, Henk J; Kools, Harrie J; van der Lee, Martijn K; van der Weg, Guido; Mol, Hans G J
2012-11-09
A new alternative data processing tool set, metAlignID, is developed for automated pre-processing and library-based identification and concentration estimation of target compounds after analysis by comprehensive two-dimensional gas chromatography with mass spectrometric detection. The tool set has been developed for and tested on LECO data. The software is developed to run multi-threaded (one thread per processor core) on a standard PC (personal computer) under different operating systems and is as such capable of processing multiple data sets simultaneously. Raw data files are converted into netCDF (network Common Data Form) format using a fast conversion tool. They are then preprocessed using previously developed algorithms originating from metAlign software. Next, the resulting reduced data files are searched against a user-composed library (derived from user or commercial NIST-compatible libraries) (NIST=National Institute of Standards and Technology) and the identified compounds, including an indicative concentration, are reported in Excel format. Data can be processed batch wise. The overall time needed for conversion together with processing and searching of 30 raw data sets for 560 compounds is routinely within an hour. The screening performance is evaluated for detection of pesticides and contaminants in raw data obtained after analysis of soil and plant samples. Results are compared to the existing data-handling routine based on proprietary software (LECO, ChromaTOF). The developed software tool set, which is freely downloadable at www.metalign.nl, greatly accelerates data-analysis and offers more options for fine-tuning automated identification toward specific application needs. The quality of the results obtained is slightly better than the standard processing and also adds a quantitative estimate. The software tool set in combination with two-dimensional gas chromatography coupled to time-of-flight mass spectrometry shows great potential as a highly-automated and fast multi-residue instrumental screening method. Copyright © 2012 Elsevier B.V. All rights reserved.
Lincoln, Tricia A.; Horan-Ross, Debra A.; McHale, Michael R.; Lawrence, Gregory B.
2005-01-01
Results from blind reference-sample analyses indicated that data-quality objectives were met by at least 90 percent of the calcium, pH, potassium, and sodium samples. Data-quality objectives were met by 77 percent of the chloride samples, 83 percent of the magnesium samples, and 80 percent of the sulfate samples. There is insufficient data to evaluate the specific conductance samples.
Improving data collection processes for routine evaluation of treatment cost-effectiveness.
Monto, Sari; Penttilä, Riku; Kärri, Timo; Puolakka, Kari; Valpas, Antti; Talonpoika, Anna-Maria
2016-04-01
The healthcare system in Finland has begun routine collection of health-related quality of life (HRQoL) information for patients in hospitals to support more systematic cost-effectiveness analysis (CEA). This article describes the systematic collection of HRQoL survey data, and addresses challenges in the implementation of patient surveys and acquisition of cost data in the case hospital. Challenges include problems with incomplete data and undefined management processes. In order to support CEA of hospital treatments, improvements are sought from the process management literature and in the observation of healthcare professionals. The article has been written from an information system and process management perspective, concluding that process ownership, automation of data collection and better staff training are keys to generating more reliable data.
Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2007
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bisping, Lynn E.
2007-01-31
This document contains the calendar year 2007 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2007 in which case the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2007.
NASA Astrophysics Data System (ADS)
D'Amboise, Christopher J. L.; Müller, Karsten; Oxarango, Laurent; Morin, Samuel; Schuler, Thomas V.
2017-09-01
We present a new water percolation routine added to the one-dimensional snowpack model Crocus as an alternative to the empirical bucket routine. This routine solves the Richards equation, which describes flow of water through unsaturated porous snow governed by capillary suction, gravity and hydraulic conductivity of the snow layers. We tested the Richards routine on two data sets, one recorded from an automatic weather station over the winter of 2013-2014 at Filefjell, Norway, and the other an idealized synthetic data set. Model results using the Richards routine generally lead to higher water contents in the snow layers. Snow layers often reached a point at which the ice crystals' surface area is completely covered by a thin film of water (the transition between pendular and funicular regimes), at which feedback from the snow metamorphism and compaction routines are expected to be nonlinear. With the synthetic simulation 18 % of snow layers obtained a saturation of > 10 % and 0.57 % of layers reached saturation of > 15 %. The Richards routine had a maximum liquid water content of 173.6 kg m-3 whereas the bucket routine had a maximum of 42.1 kg m-3. We found that wet-snow processes, such as wet-snow metamorphism and wet-snow compaction rates, are not accurately represented at higher water contents. These routines feed back on the Richards routines, which rely heavily on grain size and snow density. The parameter sets for the water retention curve and hydraulic conductivity of snow layers, which are used in the Richards routine, do not represent all the snow types that can be found in a natural snowpack. We show that the new routine has been implemented in the Crocus model, but due to feedback amplification and parameter uncertainties, meaningful applicability is limited. Updating or adapting other routines in Crocus, specifically the snow compaction routine and the grain metamorphism routine, is needed before Crocus can accurately simulate the snowpack using the Richards routine.
Amukele, Timothy K; Sokoll, Lori J; Pepper, Daniel; Howard, Dana P; Street, Jeff
2015-01-01
Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV's and the CV's of our flown versus terrestrial sample pairs however CV's from the sample pairs tended to be slightly higher than analytic CV's. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.
Continuation of research into language concepts for the mission support environment: Source code
NASA Technical Reports Server (NTRS)
Barton, Timothy J.; Ratner, Jeremiah M.
1991-01-01
Research into language concepts for the Mission Control Center is presented. A computer code for source codes is presented. The file contains the routines which allow source code files to be created and compiled. The build process assumes that all elements and the COMP exist in the current directory. The build process places as much code generation as possible on the preprocessor as possible. A summary is given of the source files as used and/or manipulated by the build routine.
Wüppenhorst, N; Consoir, C; Lörch, D; Schneider, C
2012-10-01
Several protocols for direct matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOF MS) from positive blood cultures are currently used to speed up the diagnostic process of bacteraemia. Identification rates are high and results are accurate for the BACTEC™ system and for charcoal-free bottles. Only a few studies have evaluated protocols for charcoal-containing BacT/ALERT bottles reaching substantially lower identification rates. We established a new protocol for sample preparation from aerobic and anaerobic positive charcoal-containing BacT/ALERT blood culture bottles and measured the protein profiles (n = 167). Then, we integrated this protocol in the routine workflow of our laboratory (n = 212). During the establishment of our protocol, 74.3 % of bacteria were correctly identified to the species level, in 23.4 %, no result and in 2.4 %, a false identification were obtained. Reliable criteria for correct species identification were a score value ≥1.400 and a best match on rank 1-3 of the same species. Identification rates during routine workflow were 77.8 % for correct identification, 20.8 % for not identified samples and 1.4 % for discordant identification. In conclusion, our results indicate that MALDI-TOF MS is possible, even from charcoal-containing blood cultures. Reliable criteria for correct species identification are a score value ≥1.400 and a best match on rank 1-3 of a single species.
Scheikl, Ute; Tsao, Han-Fei; Horn, Matthias; Indra, Alexander; Walochnik, Julia
2016-09-01
Free-living amoebae (FLA) are widely spread in the environment and known to cause rare but often serious infections. Besides this, FLA may serve as vehicles for bacterial pathogens. In particular, Legionella pneumophila is known to replicate within FLA thereby also gaining enhanced infectivity. Cooling towers have been the source of outbreaks of Legionnaires' disease in the past and are thus usually screened for legionellae on a routine basis, not considering, however, FLA and their vehicle function. The aim of this study was to incorporate a screening system for host amoebae into a Legionella routine screening. A new real-time PCR-based screening system for various groups of FLA was established. Three cooling towers were screened every 2 weeks over the period of 1 year for FLA and Legionella spp., by culture and molecular methods in parallel. Altogether, 83.3 % of the cooling tower samples were positive for FLA, Acanthamoeba being the dominating genus. Interestingly, 69.7 % of the cooling tower samples were not suitable for the standard Legionella screening due to their high organic burden. In the remaining samples, positivity for Legionella spp. was 25 % by culture, but overall positivity was 50 % by molecular methods. Several amoebal isolates revealed intracellular bacteria.
Gaudiano, Brandon A; Weinstock, Lauren M; Epstein-Lubow, Gary; Uebelacker, Lisa A; Miller, Ivan W
2016-02-01
In routine practice, major depressive disorder (MDD) with psychotic features often goes under-recognized and undertreated. Previous research has specified several demographic and clinical differences in MDD patients with psychotic features compared with those without psychosis in routine outpatient practice, but there is little systematic research in modern routine hospital settings. We conducted a retrospective electronic medical records chart review of 1,314 patients diagnosed with MDD who were admitted consecutively to a major psychiatric hospital over a 1-year period. We examined the prevalence of psychotic features in the sample and investigated the differences in demographic variables, clinical characteristics, and medication use patterns among patients with and without psychosis. The prevalence of psychotic features was 13.2% in the current hospital sample. Patients with psychotic depression were more likely to be older, male, a member of a racial/ethnic minority, and have more medical comorbidities and certain Axis I disorders compared with nonpsychotic patients. In addition, patients with psychotic depression were more likely to be prescribed antipsychotics and hypnotics before admission. Several demographic and clinical characteristics differentiate MDD patients with psychosis from those without psychosis in hospital settings that may be helpful in identifying these patients. Comparisons with outpatient samples and treatments implications are discussed.
Playing with Rules around Routines: Children Making Mealtimes Meaningful and Enjoyable
ERIC Educational Resources Information Center
Alcock, Sophie
2007-01-01
Children attending early childhood education and care centres spend a lot of time fitting in with institutional routines. This paper uses ethnographic methods and sociocultural activity theory to describe and analyse the processes whereby young children in an early childhood centre collectively created meaning and interest during potentially…
HATS: A Design Procedure for Routine Business Documents.
ERIC Educational Resources Information Center
Baker, William H.
2001-01-01
Describes an approach to teaching students a basic design process for routine business documents like memos, letters, and reports. Outlines the design principles of HATS (Headings, Access, Typography, and Spacing), how they apply in before-and-after fashion to various documents, and discusses an assignment in which students redesign an existing…
Jarvis, Jodie A; Franke, Mary A; Davis, April D
2016-08-01
An examination using the routine rabies direct fluorescent antibody test was performed on rabies or Eastern equine encephalitis positive mammalian brain tissue to assess inactivation of the virus. Neither virus was inactivated with acetone fixation nor the routine test, thus laboratory employees should treat all samples as rabies and when appropriate Eastern equine encephalitis positive throughout the whole procedure. Copyright © 2016 Elsevier B.V. All rights reserved.
Adler, Jonathan M; Harmeling, Luke H; Walder-Biesanz, Ilana
2013-10-01
The present study had two aims: (a) to replicate previous findings regarding the characteristics of sudden gains (SGs) in psychotherapy under routine clinical conditions and (b) to examine whether clients' narrative meaning-making processes were associated with SGs in mental health. 54 psychotherapy clients completed the Systemic Therapy Inventory of Change (Pinsof et al., 2009) and wrote private narratives prior to beginning treatment and between every session for 12 assessment points over the course of psychotherapy for a variety of presenting problems. Clients' narratives were coded using existing systems (Adler, 2012; A. M. Hayes, Feldman, & Goldfried, 2006) to assess their content in eight themes: processing, avoidance, coherence, positive self, negative self, agency, hope, and hopelessness. The prevalence, magnitude, and timing of SGs in mental health observed in the present study were similar to those observed in prior research. Two narrative meaning-making processes-processing and coherence-were significantly associated with SGs in mental health. The present study significantly extends prior research on SGs, replicating the characteristics of these gains in routine clinical conditions with a measure of general functioning and identifying two narrative meaning-making processes that are associated with SGs in mental health.
PDT - PARTICLE DISPLACEMENT TRACKING SOFTWARE
NASA Technical Reports Server (NTRS)
Wernet, M. P.
1994-01-01
Particle Imaging Velocimetry (PIV) is a quantitative velocity measurement technique for measuring instantaneous planar cross sections of a flow field. The technique offers very high precision (1%) directionally resolved velocity vector estimates, but its use has been limited by high equipment costs and complexity of operation. Particle Displacement Tracking (PDT) is an all-electronic PIV data acquisition and reduction procedure which is simple, fast, and easily implemented. The procedure uses a low power, continuous wave laser and a Charged Coupled Device (CCD) camera to electronically record the particle images. A frame grabber board in a PC is used for data acquisition and reduction processing. PDT eliminates the need for photographic processing, system costs are moderately low, and reduced data are available within seconds of acquisition. The technique results in velocity estimate accuracies on the order of 5%. The software is fully menu-driven from the acquisition to the reduction and analysis of the data. Options are available to acquire a single image or 5- or 25-field series of images separated in time by multiples of 1/60 second. The user may process each image, specifying its boundaries to remove unwanted glare from the periphery and adjusting its background level to clearly resolve the particle images. Data reduction routines determine the particle image centroids and create time history files. PDT then identifies the velocity vectors which describe the particle movement in the flow field. Graphical data analysis routines are included which allow the user to graph the time history files and display the velocity vector maps, interpolated velocity vector grids, iso-velocity vector contours, and flow streamlines. The PDT data processing software is written in FORTRAN 77 and the data acquisition routine is written in C-Language for 80386-based IBM PC compatibles running MS-DOS v3.0 or higher. Machine requirements include 4 MB RAM (3 MB Extended), a single or multiple frequency RGB monitor (EGA or better), a math co-processor, and a pointing device. The printers supported by the graphical analysis routines are the HP Laserjet+, Series II, and Series III with at least 1.5 MB memory. The data acquisition routines require the EPIX 4-MEG video board and optional 12.5MHz oscillator, and associated EPIX software. Data can be acquired from any CCD or RS-170 compatible video camera with pixel resolution of 600hX400v or better. PDT is distributed on one 5.25 inch 360K MS-DOS format diskette. Due to the use of required proprietary software, executable code is not provided on the distribution media. Compiling the source code requires the Microsoft C v5.1 compiler, Microsoft QuickC v2.0, the Microsoft Mouse Library, EPIX Image Processing Libraries, the Microway NDP-Fortran-386 v2.1 compiler, and the Media Cybernetics HALO Professional Graphics Kernal System. Due to the complexities of the machine requirements, COSMIC strongly recommends the purchase and review of the documentation prior to the purchase of the program. The source code, and sample input and output files are provided in PKZIP format; the PKUNZIP utility is included. PDT was developed in 1990. All trade names used are the property of their respective corporate owners.
Balaram, V.; Mathur, R.; Banakar, V.K.; Hein, J.R.; Rao, C.R.M.; Gnaneswara, Rao T.; Dasaram, B.
2006-01-01
Platinum group elements (PGE) and Au data in polymetallic oceanic ferromanganese nodule reference samples and crust samples obtained by inductively coupled plasma mass spectrometry (ICP-MS), after separation and pre-concentration by nickel sulfide fire-assay and Te coprecipitation, are presented. By optimizing several critical parameters such as flux composition, matrix matching calibration, etc., best experimental conditions were established to develop a method suitable for routine analysis of manganese nodule samples for PGE and Au. Calibrations were performed using international PGE reference materials, WMG-1 and WMS-1. This improved procedure offers extremely low detection limits in the range of 0.004 to 0.016 ng/g. The results obtained in this study for the reference materials compare well with previously published data wherever available. New PGE data arc also provided on some international manganese nodule reference materials. The analytical methodology described here can be used for the routine analysis of manganese nodule and crust samples in marine geochemical studies.
Headley, J V; Peru, K M; Mohamed, M H; Frank, R A; Martin, J W; Hazewinkel, R R O; Humphries, D; Gurprasad, N P; Hewitt, L M; Muir, D C G; Lindeman, D; Strub, R; Young, R F; Grewer, D M; Whittal, R M; Fedorak, P M; Birkholz, D A; Hindle, R; Reisdorph, R; Wang, X; Kasperski, K L; Hamilton, C; Woudneh, M; Wang, G; Loescher, B; Farwell, A; Dixon, D G; Ross, M; Pereira, A Dos Santos; King, E; Barrow, M P; Fahlman, B; Bailey, J; McMartin, D W; Borchers, C H; Ryan, C H; Toor, N S; Gillis, H M; Zuin, L; Bickerton, G; Mcmaster, M; Sverko, E; Shang, D; Wilson, L D; Wrona, F J
2013-01-01
This article provides a review of the routine methods currently utilized for total naphthenic acid analyses. There is a growing need to develop chemical methods that can selectively distinguish compounds found within industrially derived oil sands process affected waters (OSPW) from those derived from the natural weathering of oil sands deposits. Attention is thus given to the characterization of other OSPW components such as oil sands polar organic compounds, PAHs, and heavy metals along with characterization of chemical additives such as polyacrylamide polymers and trace levels of boron species. Environmental samples discussed cover the following matrices: OSPW containments, on-lease interceptor well systems, on- and off-lease groundwater, and river and lake surface waters. There are diverse ranges of methods available for analyses of total naphthenic acids. However, there is a need for inter-laboratory studies to compare their accuracy and precision for routine analyses. Recent advances in high- and medium-resolution mass spectrometry, concomitant with comprehensive mass spectrometry techniques following multi-dimensional chromatography or ion-mobility separations, have allowed for the speciation of monocarboxylic naphthenic acids along with a wide range of other species including humics. The distributions of oil sands polar organic compounds, particularly the sulphur containing species (i.e., OxS and OxS2) may allow for distinguishing sources of OSPW. The ratios of oxygen- (i.e., Ox) and nitrogen-containing species (i.e., NOx, and N2Ox) are useful for differentiating organic components derived from OSPW from natural components found within receiving waters. Synchronous fluorescence spectroscopy also provides a powerful screening technique capable of quickly detecting the presence of aromatic organic acids contained within oil sands naphthenic acid mixtures. Synchronous fluorescence spectroscopy provides diagnostic profiles for OSPW and potentially impacted groundwater that can be compared against reference groundwater and surface water samples. Novel applications of X-ray absorption near edge spectroscopy (XANES) are emerging for speciation of sulphur-containing species (both organic and inorganic components) as well as industrially derived boron-containing species. There is strong potential for an environmental forensics application of XANES for chemical fingerprinting of weathered sulphur-containing species and industrial additives in OSPW.
Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas
2014-12-02
Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.
Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.
2000-01-01
The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).
Cankar, Katarina; Štebih, Dejan; Dreo, Tanja; Žel, Jana; Gruden, Kristina
2006-01-01
Background Real-time PCR is the technique of choice for nucleic acid quantification. In the field of detection of genetically modified organisms (GMOs) quantification of biotech products may be required to fulfil legislative requirements. However, successful quantification depends crucially on the quality of the sample DNA analyzed. Methods for GMO detection are generally validated on certified reference materials that are in the form of powdered grain material, while detection in routine laboratories must be performed on a wide variety of sample matrixes. Due to food processing, the DNA in sample matrixes can be present in low amounts and also degraded. In addition, molecules of plant origin or from other sources that affect PCR amplification of samples will influence the reliability of the quantification. Further, the wide variety of sample matrixes presents a challenge for detection laboratories. The extraction method must ensure high yield and quality of the DNA obtained and must be carefully selected, since even components of DNA extraction solutions can influence PCR reactions. GMO quantification is based on a standard curve, therefore similarity of PCR efficiency for the sample and standard reference material is a prerequisite for exact quantification. Little information on the performance of real-time PCR on samples of different matrixes is available. Results Five commonly used DNA extraction techniques were compared and their suitability for quantitative analysis was assessed. The effect of sample matrix on nucleic acid quantification was assessed by comparing 4 maize and 4 soybean matrixes. In addition 205 maize and soybean samples from routine analysis were analyzed for PCR efficiency to assess variability of PCR performance within each sample matrix. Together with the amount of DNA needed for reliable quantification, PCR efficiency is the crucial parameter determining the reliability of quantitative results, therefore it was chosen as the primary criterion by which to evaluate the quality and performance on different matrixes and extraction techniques. The effect of PCR efficiency on the resulting GMO content is demonstrated. Conclusion The crucial influence of extraction technique and sample matrix properties on the results of GMO quantification is demonstrated. Appropriate extraction techniques for each matrix need to be determined to achieve accurate DNA quantification. Nevertheless, as it is shown that in the area of food and feed testing matrix with certain specificities is impossible to define strict quality controls need to be introduced to monitor PCR. The results of our study are also applicable to other fields of quantitative testing by real-time PCR. PMID:16907967
Software fault tolerance in computer operating systems
NASA Technical Reports Server (NTRS)
Iyer, Ravishankar K.; Lee, Inhwan
1994-01-01
This chapter provides data and analysis of the dependability and fault tolerance for three operating systems: the Tandem/GUARDIAN fault-tolerant system, the VAX/VMS distributed system, and the IBM/MVS system. Based on measurements from these systems, basic software error characteristics are investigated. Fault tolerance in operating systems resulting from the use of process pairs and recovery routines is evaluated. Two levels of models are developed to analyze error and recovery processes inside an operating system and interactions among multiple instances of an operating system running in a distributed environment. The measurements show that the use of process pairs in Tandem systems, which was originally intended for tolerating hardware faults, allows the system to tolerate about 70% of defects in system software that result in processor failures. The loose coupling between processors which results in the backup execution (the processor state and the sequence of events occurring) being different from the original execution is a major reason for the measured software fault tolerance. The IBM/MVS system fault tolerance almost doubles when recovery routines are provided, in comparison to the case in which no recovery routines are available. However, even when recovery routines are provided, there is almost a 50% chance of system failure when critical system jobs are involved.
Miller, Alison L.; Song, Ju-Hyun; Sturza, Julie; Lumeng, Julie C.; Rosenblum, Katherine; Kaciroti, Niko; Vazquez, Delia M.
2018-01-01
Biological and social influences both shape emotion regulation. In 380 low-income children, we tested whether biological stress profile (cortisol) moderated the association among positive and negative home environment factors (routines; chaos) and emotion regulation (negative lability; positive regulation). Children (M age = 50.6, SD = 6.4 months) provided saliva samples to assess diurnal cortisol parameters across 3 days. Parents reported on home environment and child emotion regulation. Structural equation modeling was used to test whether cortisol parameters moderated associations between home environment and child emotion regulation. Results showed that home chaos was negatively associated with emotion regulation outcomes; cortisol did not moderate the association. Child cortisol level moderated the routines-emotion regulation association such that lack of routine was most strongly associated with poor emotion regulation among children with lower cortisol output. Findings suggest that underlying child stress biology may shape response to environmental influences. PMID:27594200
Muthukrishnan, Madhanmohan; Singanallur, Nagendrakumar B; Ralla, Kumar; Villuppanoor, Srinivasan A
2008-08-01
Foot-and-mouth disease virus (FMDV) samples transported to the laboratory from far and inaccessible areas for serodiagnosis pose a major problem in a tropical country like India, where there is maximum temperature fluctuation. Inadequate storage methods lead to spoilage of FMDV samples collected from clinically positive animals in the field. Such samples are declared as non-typeable by the typing laboratories with the consequent loss of valuable epidemiological data. The present study evaluated the usefulness of FTA Classic Cards for the collection, shipment, storage and identification of the FMDV genome by RT-PCR and real-time RT-PCR. The stability of the viral RNA, the absence of infectivity and ease of processing the sample for molecular methods make the FTA cards a useful option for transport of FMDV genome for identification and serotyping. The method can be used routinely for FMDV research as it is economical and the cards can be transported easily in envelopes by regular document transport methods. Live virus cannot be isolated from samples collected in FTA cards, which is a limitation. This property can be viewed as an advantage as it limits the risk of transmission of live virus.
Direct and long-term detection of gene doping in conventional blood samples.
Beiter, T; Zimmermann, M; Fragasso, A; Hudemann, J; Niess, A M; Bitzer, M; Lauer, U M; Simon, P
2011-03-01
The misuse of somatic gene therapy for the purpose of enhancing athletic performance is perceived as a coming threat to the world of sports and categorized as 'gene doping'. This article describes a direct detection approach for gene doping that gives a clear yes-or-no answer based on the presence or absence of transgenic DNA in peripheral blood samples. By exploiting a priming strategy to specifically amplify intronless DNA sequences, we developed PCR protocols allowing the detection of very small amounts of transgenic DNA in genomic DNA samples to screen for six prime candidate genes. Our detection strategy was verified in a mouse model, giving positive signals from minute amounts (20 μl) of blood samples for up to 56 days following intramuscular adeno-associated virus-mediated gene transfer, one of the most likely candidate vector systems to be misused for gene doping. To make our detection strategy amenable for routine testing, we implemented a robust sample preparation and processing protocol that allows cost-efficient analysis of small human blood volumes (200 μl) with high specificity and reproducibility. The practicability and reliability of our detection strategy was validated by a screening approach including 327 blood samples taken from professional and recreational athletes under field conditions.
A simple pore water hydrogen diffusion syringe sampler
Vroblesky, D.A.; Chapelle, F.H.; Bradley, P.M.
2007-01-01
Molecular hydrogen (H2) is an important intermediate product and electron donor in microbial metabolism. Concentrations of dissolved H 2 are often diagnostic of the predominant terminal electron-accepting processes in ground water systems or aquatic sediments. H2 concentrations are routinely measured in ground water monitoring wells but are rarely measured in saturated aquatic sediments due to a lack of simple and practical sampling methods. This report describes the design and development (including laboratory and field testing) of a simple, syringe-based H 2 sampler in (1) saturated, riparian sediments, (2) surface water bed sediments, and (3) packed intervals of a fractured bedrock borehole that are inaccessible by standard pumped methods. ?? 2007 National Ground Water Association.
NASA JSC water monitor system: City of Houston field demonstration
NASA Technical Reports Server (NTRS)
Taylor, R. E.; Jeffers, E. L.; Fricks, D. H.
1979-01-01
A water quality monitoring system with on-line and real time operation similar to the function in a spacecraft was investigated. A system with the capability to determine conformance to future high effluent quality standards and to increase the potential for reclamation and reuse of water was designed. Although all system capabilities were not verified in the initial field trial, fully automated operation over a sustained period with only routine manual adjustments was accomplished. Two major points were demonstrated: (1) the water monitor system has great potential in water monitoring and/or process control applications; and (2) the water monitor system represents a vast improvement over conventional (grab sample) water monitoring techniques.
NMR measurements on the triumf polarized deuterium target
NASA Astrophysics Data System (ADS)
Wait, G. D.; Delheij, P. P. J.; Healey, D. C.
1989-01-01
The NMR system and the polarization measurements of the TRIUMF polarized deuterium target are described. The NMR tuned circuit is kept resonant at all frequencies to allow for a high gain in the rf amplifiers and to permit the measurement of the real part of the NMR signal. A Starburst (J-11) and an LSI-11 are used to process the NMR signal at a high sample rate. A synthesizer under the control of an 8085 based microprocessor (TRIMAC) provides the rf sweep. Vector polarizations between -0.33 and -0.40 were routinely achieved during a four week run in the TRIUMF M11 pion beamline with a statistical uncertainty of 3.4% and a systematic uncertainty of 5%.
Tseng, Hsin-Wu; Fan, Jiahua; Kupinski, Matthew A.
2016-01-01
Abstract. The use of a channelization mechanism on model observers not only makes mimicking human visual behavior possible, but also reduces the amount of image data needed to estimate the model observer parameters. The channelized Hotelling observer (CHO) and channelized scanning linear observer (CSLO) have recently been used to assess CT image quality for detection tasks and combined detection/estimation tasks, respectively. Although the use of channels substantially reduces the amount of data required to compute image quality, the number of scans required for CT imaging is still not practical for routine use. It is our desire to further reduce the number of scans required to make CHO or CSLO an image quality tool for routine and frequent system validations and evaluations. This work explores different data-reduction schemes and designs an approach that requires only a few CT scans. Three different kinds of approaches are included in this study: a conventional CHO/CSLO technique with a large sample size, a conventional CHO/CSLO technique with fewer samples, and an approach that we will show requires fewer samples to mimic conventional performance with a large sample size. The mean value and standard deviation of areas under ROC/EROC curve were estimated using the well-validated shuffle approach. The results indicate that an 80% data reduction can be achieved without loss of accuracy. This substantial data reduction is a step toward a practical tool for routine-task-based QA/QC CT system assessment. PMID:27493982
Quantitative Analysis of Food and Feed Samples with Droplet Digital PCR
Morisset, Dany; Štebih, Dejan; Milavec, Mojca; Gruden, Kristina; Žel, Jana
2013-01-01
In this study, the applicability of droplet digital PCR (ddPCR) for routine analysis in food and feed samples was demonstrated with the quantification of genetically modified organisms (GMOs). Real-time quantitative polymerase chain reaction (qPCR) is currently used for quantitative molecular analysis of the presence of GMOs in products. However, its use is limited for detecting and quantifying very small numbers of DNA targets, as in some complex food and feed matrices. Using ddPCR duplex assay, we have measured the absolute numbers of MON810 transgene and hmg maize reference gene copies in DNA samples. Key performance parameters of the assay were determined. The ddPCR system is shown to offer precise absolute and relative quantification of targets, without the need for calibration curves. The sensitivity (five target DNA copies) of the ddPCR assay compares well with those of individual qPCR assays and of the chamber digital PCR (cdPCR) approach. It offers a dynamic range over four orders of magnitude, greater than that of cdPCR. Moreover, when compared to qPCR, the ddPCR assay showed better repeatability at low target concentrations and a greater tolerance to inhibitors. Finally, ddPCR throughput and cost are advantageous relative to those of qPCR for routine GMO quantification. It is thus concluded that ddPCR technology can be applied for routine quantification of GMOs, or any other domain where quantitative analysis of food and feed samples is needed. PMID:23658750
Improving laboratory results turnaround time by reducing pre analytical phase.
Khalifa, Mohamed; Khalid, Parwaiz
2014-01-01
Laboratory turnaround time is considered one of the most important indicators of work efficiency in hospitals, physicians always need timely results to take effective clinical decisions especially in the emergency department where these results can guide physicians whether to admit patients to the hospital, discharge them home or do further investigations. A retrospective data analysis study was performed to identify the effects of ER and Lab staff training on new routines for sample collection and transportation on the pre-analytical phase of turnaround time. Renal profile tests requested by the ER and performed in 2013 has been selected as a sample, and data about 7,519 tests were retrieved and analyzed to compare turnaround time intervals before and after implementing new routines. Results showed significant time reduction on "Request to Sample Collection" and "Collection to In Lab Delivery" time intervals with less significant improvement on the analytical phase of the turnaround time.
Actinobaculum schaalii, a Common Uropathogen in Elderly Patients, Denmark
Jensen, Anders; Hansen, Thomas M.; Søby, Karen M.; Prag, Jørgen
2010-01-01
Actinobaculum schaalii can cause urinary tract infections and septicemia but is difficult to identify by cultivation. To obtain a fast diagnosis and identify A. schaalii, we developed a TaqMan real-time quantitative PCR. Routine urine samples were obtained from 177 hospitalized patients and 75 outpatients in Viborg County, Denmark, in 2008–2009. The PCR detected A. schaalii in 22% of samples from patients >60 years of age. This assay showed that A. schaalii is more common than implied by routine cultivation. In 90% of PCR-positive urine samples, other common uropathogens were identified. This finding suggests that A. schaalii is a common, undetected, bacterial pathogen. Our results suggest that A. schaalii may be a more common pathogen than previously thought, especially in patients with unexplained chronic urinary tract infections, who are often treated with trimethoprim or ciprofloxacin, to which A. schaalii is resistant. PMID:20031046
Toxicity studies of a polyurethane rigid foam
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Schneider, J. E.
1977-01-01
Relative toxicity tests were performed on a polyurethane foam containing a trimethylopropane-based polyol and an organophosphate flame retardant. The routine screening procedure involved the exposure of four Swiss albino male mice in a 4.2 liter hemispherical chamber to the products generated by pyrolyzing a 1.00 g sample at a heating rate of 40 deg C/min from 200 to 800 C in the absence of air flow. In addition to the routine screening, experiments were performed with a very rapid rise to 800 C, with nominal 16 and 48 ml/sec air flow and with varying sample rates. No unusual toxicity was observed with either gradual or rapid pyrolysis to 800 C. Convulsions and seizures similar to those previously reported were observed when the materials were essentially flash pyrolyzed at 800 C in the presence of air flow, and the toxicity appeared unusual because of low sample weights required to produce death.
Pardo, Miguel Angel
2015-04-01
A dual-probe real time PCR assay, based on the simultaneous detection of two TaqMan® probes, was evaluated for the detection of mandarin in orange juice. A single conserved polymorphism, located at the 314 position of intron belongs to chloroplast trnL gene, was confirmed by sequencing in 30 mandarin, 28 orange cultivars and 13 hybrids. The assay was also successfully evaluated in a blind trial against analysing 60 samples from different industrial processes in different countries around the world. The detection limit of the assay was established in 1% presence of mandarin detectable in processed orange juice and with a 100% precision. The quantitative application of the assay on citrus mixtures was also investigated, pointing out that the number of chloroplast DNA copies is too variable for its possible use as quantitative analysis. This assay can be employed as a routine methodology to control the accidental mixing during industrial processes and to deter intentional fraud. Copyright © 2014 Elsevier Ltd. All rights reserved.
2014-01-01
Background The quality of routine indoor residual spraying (IRS) operations is rarely assessed because of the limited choice of methods available for quantifying insecticide content in the field. This study, therefore, evaluated a user-friendly, rapid colorimetric assay for detecting insecticide content after routine IRS operations were conducted. Methods This study was conducted in Tafea Province, Vanuatu. Routine IRS was conducted with lambda cyhalothrin. Two methods were used to quantify the IRS activities: 1) pre-spray application of small felt pads and 2) post-spray removal of insecticide with adhesive. The insecticide content was quantified using a colorimetric assay (Insecticide Quantification Kit [IQK]), which involved exposing each sample to the test reagents for 15 mins. The concentration of insecticide was indicated by the depth of red colour. Results The IQK proved simple to perform in the field and results could be immediately interpreted by the programme staff. The insecticide content was successfully sampled by attaching felt pads to the house walls prior to spraying. The IRS operation was well conducted, with 83% of houses being sprayed at the target dose (20 – 30 mg AI/m2). The average reading across all houses was 24.4 ± 1.5 mg AI/m2. The results from the felt pads applied pre-spray were used as a base to compare methods for sampling insecticide from walls post-spray. The adhesive of Sellotape did not collect adequate samples. However, the adhesive of the felt pads provided accurate samples of the insecticide content on walls. Conclusion The IQK colorimetric assay proved to be a useful tool that was simple to use under realistic field conditions. The assay provided rapid information on IRS spray dynamics and spray team performance, facilitating timely decision making and reporting for programme managers. The IQK colorimetric assay will have direct applications for routine quality control in malaria control programmes globally and has the potential to improve the efficacy of vector control operations. PMID:24885084
An advanced software suite for the processing and analysis of silicon luminescence images
NASA Astrophysics Data System (ADS)
Payne, D. N. R.; Vargas, C.; Hameiri, Z.; Wenham, S. R.; Bagnall, D. M.
2017-06-01
Luminescence imaging is a versatile characterisation technique used for a broad range of research and industrial applications, particularly for the field of photovoltaics where photoluminescence and electroluminescence imaging is routinely carried out for materials analysis and quality control. Luminescence imaging can reveal a wealth of material information, as detailed in extensive literature, yet these techniques are often only used qualitatively instead of being utilised to their full potential. Part of the reason for this is the time and effort required for image processing and analysis in order to convert image data to more meaningful results. In this work, a custom built, Matlab based software suite is presented which aims to dramatically simplify luminescence image processing and analysis. The suite includes four individual programs which can be used in isolation or in conjunction to achieve a broad array of functionality, including but not limited to, point spread function determination and deconvolution, automated sample extraction, image alignment and comparison, minority carrier lifetime calibration and iron impurity concentration mapping.
Automated processing for proton spectroscopic imaging using water reference deconvolution.
Maudsley, A A; Wu, Z; Meyerhoff, D J; Weiner, M W
1994-06-01
Automated formation of MR spectroscopic images (MRSI) is necessary before routine application of these methods is possible for in vivo studies; however, this task is complicated by the presence of spatially dependent instrumental distortions and the complex nature of the MR spectrum. A data processing method is presented for completely automated formation of in vivo proton spectroscopic images, and applied for analysis of human brain metabolites. This procedure uses the water reference deconvolution method (G. A. Morris, J. Magn. Reson. 80, 547(1988)) to correct for line shape distortions caused by instrumental and sample characteristics, followed by parametric spectral analysis. Results for automated image formation were found to compare favorably with operator dependent spectral integration methods. While the water reference deconvolution processing was found to provide good correction of spatially dependent resonance frequency shifts, it was found to be susceptible to errors for correction of line shape distortions. These occur due to differences between the water reference and the metabolite distributions.
[QUIPS: quality improvement in postoperative pain management].
Meissner, Winfried
2011-01-01
Despite the availability of high-quality guidelines and advanced pain management techniques acute postoperative pain management is still far from being satisfactory. The QUIPS (Quality Improvement in Postoperative Pain Management) project aims to improve treatment quality by means of standardised data acquisition, analysis of quality and process indicators, and feedback and benchmarking. During a pilot phase funded by the German Ministry of Health (BMG), a total of 12,389 data sets were collected from six participating hospitals. Outcome improved in four of the six hospitals. Process indicators, such as routine pain documentation, were only poorly correlated with outcomes. To date, more than 130 German hospitals use QUIPS as a routine quality management tool. An EC-funded parallel project disseminates the concept internationally. QUIPS demonstrates that patient-reported outcomes in postoperative pain management can be benchmarked in routine clinical practice. Quality improvement initiatives should use outcome instead of structural and process parameters. The concept is transferable to other fields of medicine. Copyright © 2011. Published by Elsevier GmbH.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS INITIAL AND ROUTINE... will be restricted to verifying the absence of undeclared scheduled chemicals, unless otherwise agreed...
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND SECURITY, DEPARTMENT OF COMMERCE CHEMICAL WEAPONS CONVENTION REGULATIONS INITIAL AND ROUTINE... will be restricted to verifying the absence of undeclared scheduled chemicals, unless otherwise agreed...
A Nursing Intelligence System to Support Secondary Use of Nursing Routine Data
Rauchegger, F.; Ammenwerth, E.
2015-01-01
Summary Background Nursing care is facing exponential growth of information from nursing documentation. This amount of electronically available data collected routinely opens up new opportunities for secondary use. Objectives To present a case study of a nursing intelligence system for reusing routinely collected nursing documentation data for multiple purposes, including quality management of nursing care. Methods The SPIRIT framework for systematically planning the reuse of clinical routine data was leveraged to design a nursing intelligence system which then was implemented using open source tools in a large university hospital group following the spiral model of software engineering. Results The nursing intelligence system is in routine use now and updated regularly, and includes over 40 million data sets. It allows the outcome and quality analysis of data related to the nursing process. Conclusions Following a systematic approach for planning and designing a solution for reusing routine care data appeared to be successful. The resulting nursing intelligence system is useful in practice now, but remains malleable for future changes. PMID:26171085
Göen, Thomas; Lermen, Dominik; Hildebrand, Jörg; Bartel-Steinbach, Martina; Weber, Till; Kolossa-Gehring, Marike
2018-06-12
The German Environmental Specimen Bank (ESB) is a monitoring instrument of the German Federal Ministry for the Environment, Nature Conservationand Nuclear Safety. The permanent biobank facility is run since 1981 containing environmental and human samples from Germany. All samples are collected according to standard operating procedures (SOP). An annually standardized collection of human samples at four different regional sites of the country has been established since 1997. Routine sampling is done once a year, recruiting healthy non occupationally exposed students aged 20-29 years, in an equal gender distribution. The number of participants recruited is approximately 120 students per site and year. Directly after the annual sampling process, the human samples are analyzed for selected environmental chemicals. The time-trends of lead in blood, mercury and pentachlorophenol in 24 h-urine and polychlorinated biphenyls in plasma demonstrated a decrease of exposure during the last two decades by about 40 - 90 percent. In parallel retrospective studies using cryo-archived samples revealed increasing time trends of emerging chemicals used as substitutes for regulated toxicants. The data demonstrates the great relevance of the ESB for the health related environmental monitoring and shows the importance of human biomonitoring as a tool in information based policy making. Copyright © 2018 Elsevier B.V. All rights reserved.
Rostami, Paryaneh; Ashcroft, Darren M; Tully, Mary P
2018-01-01
Reducing medication-related harm is a global priority; however, impetus for improvement is impeded as routine medication safety data are seldom available. Therefore, the Medication Safety Thermometer was developed within England's National Health Service. This study aimed to explore the implementation of the tool into routine practice from users' perspectives. Fifteen semi-structured interviews were conducted with purposely sampled National Health Service staff from primary and secondary care settings. Interview data were analysed using an initial thematic analysis, and subsequent analysis using Normalisation Process Theory. Secondary care staff understood that the Medication Safety Thermometer's purpose was to measure medication safety and improvement. However, other uses were reported, such as pinpointing poor practice. Confusion about its purpose existed in primary care, despite further training, suggesting unsuitability of the tool. Decreased engagement was displayed by staff less involved with medication use, who displayed less ownership. Nonetheless, these advocates often lacked support from management and frontline levels, leading to an overall lack of engagement. Many participants reported efforts to drive scale-up of the use of the tool, for example, by securing funding, despite uncertainty around how to use data. Successful improvement was often at ward-level and went unrecognised within the wider organisation. There was mixed feedback regarding the value of the tool, often due to a perceived lack of "capacity". However, participants demonstrated interest in learning how to use their data and unexpected applications of data were reported. Routine medication safety data collection is complex, but achievable and facilitates improvements. However, collected data must be analysed, understood and used for further work to achieve improvement, which often does not happen. The national roll-out of the tool has accelerated shared learning; however, a number of difficulties still exist, particularly in primary care settings, where a different approach is likely to be required.
Ashcroft, Darren M.; Tully, Mary P.
2018-01-01
Background Reducing medication-related harm is a global priority; however, impetus for improvement is impeded as routine medication safety data are seldom available. Therefore, the Medication Safety Thermometer was developed within England’s National Health Service. This study aimed to explore the implementation of the tool into routine practice from users’ perspectives. Method Fifteen semi-structured interviews were conducted with purposely sampled National Health Service staff from primary and secondary care settings. Interview data were analysed using an initial thematic analysis, and subsequent analysis using Normalisation Process Theory. Results Secondary care staff understood that the Medication Safety Thermometer’s purpose was to measure medication safety and improvement. However, other uses were reported, such as pinpointing poor practice. Confusion about its purpose existed in primary care, despite further training, suggesting unsuitability of the tool. Decreased engagement was displayed by staff less involved with medication use, who displayed less ownership. Nonetheless, these advocates often lacked support from management and frontline levels, leading to an overall lack of engagement. Many participants reported efforts to drive scale-up of the use of the tool, for example, by securing funding, despite uncertainty around how to use data. Successful improvement was often at ward-level and went unrecognised within the wider organisation. There was mixed feedback regarding the value of the tool, often due to a perceived lack of “capacity”. However, participants demonstrated interest in learning how to use their data and unexpected applications of data were reported. Conclusion Routine medication safety data collection is complex, but achievable and facilitates improvements. However, collected data must be analysed, understood and used for further work to achieve improvement, which often does not happen. The national roll-out of the tool has accelerated shared learning; however, a number of difficulties still exist, particularly in primary care settings, where a different approach is likely to be required. PMID:29489842
Role of veterinarians in modern food hygiene
Matyáš, Z.
1978-01-01
Veterinary services and veterinary education and training must keep pace with the constantly changing patterns of agriculture and food processing. Changes in methods of animal production are associated with many problems of food processing and food quality. Veterinary supervision of the animal feed industry and of meat and distribution is essential. Quality testing of meat, milk, and eggs requires the introduction of suitable routine sampling systems, laboratory procedures, and complex evaluation procedures. Food hygiene problems have changed in recent years not only as a result of new methods of animal production, but also because of changes in food processing technology and in the presentation of food to the consumer, increased environmental pollution, increased international trade, and increased tourist travel. Food hygienists must adopt an active and progressive policy and change the scope of food control from a purely negative measure into a positive force working towards improved food quality and the avoidance of losses during production. A modern food hygiene programme should cover all stages of production, processing, and distribution of food and also other ingredients, additives and the water used for production and processing. Veterinarians should also be involved in the registration and licensing of enterprises and this should take into account the premises, the procedures to be used, new techniques in animal husbandry, machines and equipment, etc. In order to facilitate the microbiological analysis of foodstuffs, new mechanized or automated laboratory methods are required, and consideration must be given to adequate sampling techniques. PMID:310716
NASA Astrophysics Data System (ADS)
Bozlaker, Ayşe; Buzcu-Güven, Birnur; Fraser, Matthew P.; Chellam, Shankararaman
2013-04-01
Petroleum refineries may emit large quantities of pollutants during non-routine operations that include start-ups and shutdowns, planned maintenance, and unplanned equipment failures. The Texas Commission on Environmental Quality (TCEQ) tracks such events by requiring industries to self-report estimates of these emissions because they often have a detrimental impact on local air quality and potentially, public health. An inventory of non-routine episodic emission events is available via TCEQ's website. However, there is on-going concern that such episodic emissions are sometimes under-reported or even not cataloged. Herein, we present concentrations of 42 main group, transition, and lanthanoid elements in 114 time-resolved (3 or 6 h) samples collected over a 1-month period. We also develop strategies to identify aerosol sources using elemental tracers and compare source apportionment (performed by positive matrix factorization) based on ambient measurements to inventoried non-routine emission events. Through interpretation of key marker elements, five sources impacting concentrations of metals in PM10 were identified and calculated to contribute 73% of the measured PM10 mass. On average, primary emissions from fluidized-bed catalytic cracking (FCC) units negligibly contributed to apportioned PM10 mass. However, 35 samples were identified as impacted by transient PM10 emissions from FCC units because of elevated levels of lanthanoid metals and their ratios. Only 31 of these 35 samples coincided with self-reported non-routine emission events. Further, roughly half of the emission event self-reports detailed only emissions of gaseous pollutants. Based on this, we posit that not all PM10 emission events are reported and even self-reported emission events are incomplete - those that only catalog gaseous pollutants may also include unreported PM emissions.
Senger, Jenna-Lynn; Chandran, Geethan; Kanthan, Rani
2014-01-01
To reconsider the routine plastic surgical practice of requesting histopathological evaluation of tissue from gynecomastia. The present study was a retrospective histopathological review (15-year period [1996 to 2012]) involving gynecomastia tissue samples received at the pathology laboratory in the Saskatoon Health Region (Saskatchewan). The Laboratory Information System (LIS) identified all specimens using the key search words "gynecomastia", "gynaecomastia", "gynecomazia" and "gynaecomazia". A literature review to identify all cases of incidentally discovered malignancies in gynecomastia tissue specimens over a 15-year period (1996 to present) was undertaken. The 15-year LIS search detected a total of 452 patients that included two cases of pseudogynecomastia (0.4%). Patients' age ranged from five to 92 years and 43% of the cases were bilateral (28% left sided, 29% right sided). The weight of the specimens received ranged from 0.2 g to 1147.2 g. All cases showed no significant histopathological concerns. The number of tissue blocks sampled ranged from one to 42, averaging four blocks/case (approximately $105/case), resulting in a cost of approximately $3,200/year, with a 15-year expenditure of approximately $48,000. The literature review identified a total of 15 incidental findings: ductal carcinoma in situ (12 cases), atypical ductal hyperplasia (two cases) and infiltrating ductal carcinoma (one case). In the context of evidence-based literature, and because no significant pathological findings were detected in this particular cohort of 452 cases with 2178 slides, the authors believe it is time to re-evaluate whether routine histopathological examination of tissue from gynecomastia remains necessary. The current climate of health care budget fiscal restraints warrants reassessment of the current policies and practices of sending tissue samples of gynecomastia incurring negative productivity costs on routine histopathological examination.
Taking geoscience to the IMAX: 3D and 4D insight into geological processes using micro-CT
NASA Astrophysics Data System (ADS)
Dobson, Katherine; Dingwell, Don; Hess, Kai-Uwe; Withers, Philip; Lee, Peter; Pistone, Mattia; Fife, Julie; Atwood, Robert
2015-04-01
Geology is inherently dynamic, and full understanding of any geological system can only be achieved by considering the processes by which change occurs. Analytical limitations mean understanding has largely developed from ex situ analyses of the products of geological change, rather than of the processes themselves. Most methods essentially utilise "snap shot" sampling: and from thin section petrography to high resolution crystal chemical stratigraphy and field volcanology, we capture an incomplete view of a spatially and temporally variable system. Even with detailed experimental work, we can usually only analyse samples before and after we perform an experiment, as routine analysis methods are destructive. Serial sectioning and quenched experiments stopped at different stages can give some insight into the third and fourth dimension, but the true scaling of the processes from the laboratory to the 4D (3D + time) geosphere is still poorly understood. Micro computed tomography (XMT) can visualise the internal structures and spatial associations within geological samples non-destructively. With image resolutions of between 200 microns and 50 nanometres, tomography has the ability to provide a detailed sample assessment in 3D, and quantification of mineral associations, porosity, grain orientations, fracture alignments and many other features. This allows better understanding of the role of the complex geometries and associations within the samples, but the challenge of capturing the processes that generate and modify these structures remains. To capture processes, recent work has focused on developing experimental capability for in situ experiments on geological materials. Data presented will showcase examples from recent experiments where high speed synchrotron x-ray tomography has been used to acquire each 3D image in under 2 seconds. We present a suite of studies that showcase how it is now possible to take quantification of many geological processed into 3D and 4D. This will include tracking the interactions between bubbles and crystals in a deforming magma, the dissolution of individual mineral grains from low grade ores, and quantification of three phase flow in sediments and soils. Our aim is to demonstrate how XMT can provide new insight into dynamic processes in all geoscience disciplines, and give you some insight into where 4D geoscience could take us next.
Instrument Control (iC) – An Open-Source Software to Automate Test Equipment
Pernstich, K. P.
2012-01-01
It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming. PMID:26900522
The interdependence of lake ice and climate in central North America
NASA Technical Reports Server (NTRS)
Jelacic, A. J. (Principal Investigator)
1972-01-01
There are no author-identified significant results in this report. This investigation is to identify any correlations between the freeze/ thaw cycles of lakes and regional weather variations. ERTS-1 imagery of central Canada and north central United States is examined on a seasonal basis. The ice conditions of certain major study lakes are noted and recorded on magnetic tape, from which the movement of a freeze/thaw transition zone may be deduced. Weather maps and tables are used to establish any obvious correlations. The process of selecting major study lakes is discussed, and a complete lake directory is presented. Various routines of the software support library are described, accompanied by output samples. Procedures used for ERTS imagery processing are presented along with the data analysis plan. Application of these procedures to selected ERTS imagery has demonstrated their utility. Preliminary results show that the freeze/thaw transition zone can be monitored from ERTS.
Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.
Pernstich, K P
2012-01-01
It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.
A Statistical Analysis of the Medicare Hospital Routine Nursing Salary Cost Differential
Fitzmaurice, J. Michael
1983-01-01
From July 1971 (but effective retroactively to July 1, 1969) to October 1981, Medicare hospital reimbursement methods assumed that patients in the qualifying categories of the aged, pediatric, maternal, and kidney transplant cases consumed 8.5 percent more routine nursing resources than patients outside these categories. Consequently, the Medicare program paid this nursing differential to hospitals for all its hospitalized beneficiaries in these categories. The purpose of this study is to investigate whether hospitals with more qualifying Medicare patients do, in fact, have higher per diem routine nursing salary costs. This study tests this hypothesis while attempting to hold constant the influences of other factors such as local area wages, hospital size, occupancy rate, type of control, and geographic region. Using 1979 data from over 4,500 hospitals, and 1977, 1978, and 1979 data from a sample of 1200 hospitals, this study looks at the relationship between per diem hospital routine nursing salary costs and the proportion of qualifying Medicare routine patient days in two models. Model I incorporates the framework of the Section 223 routine cost limits and Model II incorporates a comprehensive set of variables representing the hospitals′ production and output characteristics. The evidence from this study provides little empirical basis to support the existence of a strong or sizeable relationship and, hence, does not support payment of the Medicare routine nursing salary cost differential. PMID:10310276
Mahler, Barbara J.; Musgrove, MaryLynn; Herrington, Chris; Sample, Thomas L.
2011-01-01
During 2008–10, the U.S. Geological Survey, in cooperation with the City of Austin, the City of Dripping Springs, the Barton Springs/Edwards Aquifer Conservation District, the Lower Colorado River Authority, Hays County, and Travis County, collected and analyzed water samples from five streams (Barton, Williamson, Slaughter, Bear, and Onion Creeks), two groundwater wells (Marbridge well [YD–58–50–704] and Buda well [LR–58–58–403]), and the main orifice of Barton Springs in Austin, Texas, with the objective of characterizing concentrations and isotopic compositions of nitrate and concentrations of wastewater compounds in the Barton Springs zone. The Barton Springs zone is in south-central Texas, an area undergoing rapid growth in population and in land area affected by development, with associated increases in wastewater generation. Over a period of 17 months, during which the hydrologic conditions transitioned from dry to wet, samples were collected routinely from the streams, wells, and spring and, in response to storms, from the streams and spring; some or all samples were analyzed for nitrate, nitrogen and oxygen isotopes of nitrate, and wastewater compounds. The median nitrate concentrations in routine samples from all sites were higher in samples collected during the wet period than in samples collected during the dry period, with the greatest difference for stream samples (0.05 milligram per liter during the dry period to 0.96 milligram per liter for the wet period). Nitrate concentrations in recent (2008–10) samples were elevated relative to concentrations in historical (1990–2008) samples from streams and from Barton Springs under medium- and high-flow conditions. Recent nitrate concentrations were higher than historical concentrations at the Marbridge well but the reverse was true at the Buda well. The elevated concentrations likely are related to the cessation of dry conditions coupled with increased nitrogen loading in the contributing watersheds. An isotopic composition of nitrate (delta nitrogen–15) greater than 8 per mil in many of the samples indicated there was a contribution of nitrate with a biogenic (human and or animal waste, or both) origin. Wastewater compounds measured in routine samples were detected infrequently (3 percent of cases), and concentrations were very low (less than the method reporting level in most cases). There was no correlation between nitrate concentrations and the frequency of detection of wastewater compounds, indicating that wastewater compounds might be undergoing removal during such processes as infiltration through soil. Three potential sources of biogenic nitrate to the contributing zone were considered: septic systems, land application of treated wastewater, and domesticated dogs and cats. During 2001–10, the estimated densities of septic systems and domesticated dogs and cats (number per acre) increased in the watersheds of all five creeks, and the rate of land application of treated wastewater (gallons per day per acre) increased in the watersheds of Barton, Bear, and Onion Creeks. Considering the timing and location of the increases in the three sources, septic systems were considered a likely source of increased nitrate to Bear Creek; land application of treated wastewater a likely source to Barton, Bear, and Onion Creeks; and domestic dogs and cats a potential source principally to Williamson Creek. The results of this investigation indicate that baseline water quality, in terms of nitrate, has shifted upward between 2001 and 2010, even without any direct discharges of treated wastewater to the creeks.
Creating Masterpieces: How Course Structures and Routines Enable Student Performance
ERIC Educational Resources Information Center
Dean, Kathy Lund; Fornaciari, Charles J.
2014-01-01
Over a five-year period, we made a persistent observation: Course structures and routines, such as assignment parameters, student group process rules, and grading schemes were being consistently ignored. As a result, we got distracted by correcting these structural issues and were spending less time on student assignment performance. In this…
Angelino, Elisabetta
2014-03-01
Effective implementation of change in patients' care is a substantive problem. Organizational learning is viewed as process of seeking, selecting, and adapting new "routines" to improve performance but learning from experience is not automatic, but rather may result from action and reflection within the organization.
Teaching Early Readers to Self-Monitor and Self-Correct
ERIC Educational Resources Information Center
Pratt, Sharon M.; Urbanowski, Melena
2016-01-01
Proficient readers self-monitor and self-correct to derive meaning from text. This article reviews research on how students learn to self-monitor and self-correct and describes a Reciprocal Teaching (RT) instructional routine that was successfully used with early readers to build their metacognitive processes. The RT routine included teacher…
Drama and Routine in the Public Schools.
ERIC Educational Resources Information Center
Pondy, Louis R.; Huff, Anne S.
A case study of curricular change compares two leading models of organizational change. One model stresses the uncertainty and disorder of major changes and views them as dramatic events. The other model sees major organizational shifts as the result of ordinary day-to-day processes and emphasizes their routine nature. For this study, the…
Woo, A H; Lindsay, R C
1980-07-01
A rapid quantiative method was developed for routine analysis of the major, even carbon-numbered free fatty acids in butter and cream. Free fatty acids were isolated directly from intact samples by a modified silicic acid-potassium hydroxide arrestant column and were separated by gas chromatography with a 1.8 m x 2 mm inner diameter glass column packed with 10% neopentyl glycol adipate on 80/100 Chromosorb W. Purified, formic acid-saturated carrier gas was required for minimal peak tailing and extended column life. The accuracy and reproducibility of the mmethod was established through quantitative recovery studies of free fatty acid mixtures, free fatty acids added to butter, and replicate analysis of butter and cream samples.
[The spectrum of human chromosomal aberrations detected by routine and differential (GTG) staining].
Ponomareva, A V; Matveeva, V G; Osipova, L P
2001-01-01
As a result of sample cytogenetic studies of 23 persons living on the territory of Yamal-Nentsy Autonomous District and chronically exposed to the small doses of radiation the data on the frequency and spectrum of chromosome aberrations, detected by the routine and differential (GTG) staining were obtained. Comparative efficiency of these methods was determined. The absence of significant differences for the spectrum and frequencies of chromosome aberrations revealed by both methods was shown.
Ecological Networks and Community Attachment and Support Among Recently Resettled Refugees.
Soller, Brian; Goodkind, Jessica R; Greene, R Neil; Browning, Christopher R; Shantzek, Cece
2018-03-25
Interventions aimed at enhancing mental health are increasingly centered around promoting community attachment and support. However, few have examined and tested the specific ecological factors that give rise to these key community processes. Drawing from insights from the ecological network perspective, we tested whether spatial and social overlap in routine activity settings (e.g., work, school, childcare) with fellow ethnic community members is associated with individuals' attachment to their ethnic communities and access to social resources embedded in their communities. Data on routine activity locations drawn from the Refugee Well-Being Project (based in a city in the Southwestern United States) were used to reconstruct the ecological networks of recently resettled refugee communities, which were two-mode networks that comprise individuals and their routine activity locations. Results indicated that respondents' community attachment and support increased with their ecological network extensity-which taps the extent to which respondents share routine activity locations with other community members. Our study highlights a key ecological process that potentially enhances individuals' ethnic community attachment that extends beyond residential neighborhoods. © Society for Community Research and Action 2018.
Lidierth, Malcolm
2005-02-15
This paper describes software that runs in the Spike2 for Windows environment and provides a versatile tool for generating stimuli during data acquisition from the 1401 family of interfaces (CED, UK). A graphical user interface (GUI) is used to provide dynamic control of stimulus timing. Both single stimuli and trains of stimuli can be generated. The pulse generation routines make use of programmable variables within the interface and allow these to be rapidly changed during an experiment. The routines therefore provide the ease-of-use associated with external, stand-alone pulse generators. Complex stimulus protocols can be loaded from an external text file and facilities are included to create these files through the GUI. The software consists of a Spike2 script that runs in the host PC, and accompanying routines written in the 1401 sequencer control code, that run in the 1401 interface. Handshaking between the PC and the interface card are built into the routines and provides for full integration of sampling, analysis and stimulus generation during an experiment. Control of the 1401 digital-to-analogue converters is also provided; this allows control of stimulus amplitude as well as timing and also provides a sample-hold feature that may be used to remove DC offsets and drift from recorded data.
User Interactive Software for Analysis of Human Physiological Data
NASA Technical Reports Server (NTRS)
Cowings, Patricia S.; Toscano, William; Taylor, Bruce C.; Acharya, Soumydipta
2006-01-01
Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration
Large-scale atlas of microarray data reveals biological landscape of gene expression in Arabidopsis
USDA-ARS?s Scientific Manuscript database
Transcriptome datasets from thousands of samples of the model plant Arabidopsis thaliana have been collectively generated by multiple individual labs. Although integration and meta-analysis of these samples has become routine in the plant research community, it is often hampered by the lack of metad...
Metagenomic Analysis of Viruses in Feces from Unsolved Outbreaks of Gastroenteritis in Humans
Moore, Nicole E.; Wang, Jing; Hewitt, Joanne; Croucher, Dawn; Williamson, Deborah A.; Paine, Shevaun; Yen, Seiha; Greening, Gail E.
2014-01-01
The etiology of an outbreak of gastroenteritis in humans cannot always be determined, and ∼25% of outbreaks remain unsolved in New Zealand. It is hypothesized that novel viruses may account for a proportion of unsolved cases, and new unbiased high-throughput sequencing methods hold promise for their detection. Analysis of the fecal metagenome can reveal the presence of viruses, bacteria, and parasites which may have evaded routine diagnostic testing. Thirty-one fecal samples from 26 gastroenteritis outbreaks of unknown etiology occurring in New Zealand between 2011 and 2012 were selected for de novo metagenomic analysis. A total data set of 193 million sequence reads of 150 bp in length was produced on an Illumina MiSeq. The metagenomic data set was searched for virus and parasite sequences, with no evidence of novel pathogens found. Eight viruses and one parasite were detected, each already known to be associated with gastroenteritis, including adenovirus, rotavirus, sapovirus, and Dientamoeba fragilis. In addition, we also describe the first detection of human parechovirus 3 (HPeV3) in Australasia. Metagenomics may thus provide a useful audit tool when applied retrospectively to determine where routine diagnostic processes may have failed to detect a pathogen. PMID:25339401
West, A G; Goldsmith, G R; Matimati, I; Dawson, T E
2011-08-30
Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isotope analysis. Here we report two independent tests of this post-processing spectral analysis software on two IRIS systems, OA-ICOS (Los Gatos Research Inc.) and WS-CRDS (Picarro Inc.). Following a similar methodology to a previous study, we cryogenically extracted plant leaf water and soil water and measured the δ(2)H and δ(18)O values of identical samples by isotope ratio mass spectrometry (IRMS) and IRIS. As an additional test, we analyzed plant stem waters and tap waters by IRMS and IRIS in an independent laboratory. For all tests we assumed that the IRMS value represented the "true" value against which we could compare the stable isotope results from the IRIS methods. Samples showing significant deviations from the IRMS value (>2σ) were considered to be contaminated and representative of spectral interference in the IRIS measurement. Over the two studies, 83% of plant species were considered contaminated on OA-ICOS and 58% on WS-CRDS. Post-analysis, spectra were analyzed using the manufacturer's spectral analysis software, in order to see if the software correctly identified contaminated samples. In our tests the software performed well, identifying all the samples with major errors. However, some false negatives indicate that user evaluation and testing of the software are necessary. Repeat sampling of plants showed considerable variation in the discrepancies between IRIS and IRMS. As such, we recommend that spectral analysis of IRIS data must be incorporated into standard post-processing routines. Furthermore, we suggest that the results from spectral analysis be included when reporting stable isotope data from IRIS. Copyright © 2011 John Wiley & Sons, Ltd.
Barr Fritcher, Emily G; Voss, Jesse S; Brankley, Shannon M; Campion, Michael B; Jenkins, Sarah M; Keeney, Matthew E; Henry, Michael R; Kerr, Sarah M; Chaiteerakij, Roongruedee; Pestova, Ekaterina V; Clayton, Amy C; Zhang, Jun; Roberts, Lewis R; Gores, Gregory J; Halling, Kevin C; Kipp, Benjamin R
2015-12-01
Pancreatobiliary cancer is detected by fluorescence in situ hybridization (FISH) of pancreatobiliary brush samples with UroVysion probes, originally designed to detect bladder cancer. We designed a set of new probes to detect pancreatobiliary cancer and compared its performance with that of UroVysion and routine cytology analysis. We tested a set of FISH probes on tumor tissues (cholangiocarcinoma or pancreatic carcinoma) and non-tumor tissues from 29 patients. We identified 4 probes that had high specificity for tumor vs non-tumor tissues; we called this set of probes pancreatobiliary FISH. We performed a retrospective analysis of brush samples from 272 patients who underwent endoscopic retrograde cholangiopancreatography for evaluation of malignancy at the Mayo Clinic; results were available from routine cytology and FISH with UroVysion probes. Archived residual specimens were retrieved and used to evaluate the pancreatobiliary FISH probes. Cutoff values for FISH with the pancreatobiliary probes were determined using 89 samples and validated in the remaining 183 samples. Clinical and pathologic evidence of malignancy in the pancreatobiliary tract within 2 years of brush sample collection was used as the standard; samples from patients without malignancies were used as negative controls. The validation cohort included 85 patients with malignancies (46.4%) and 114 patients with primary sclerosing cholangitis (62.3%). Samples containing cells above the cutoff for polysomy (copy number gain of ≥2 probes) were classified as positive in FISH with the UroVysion and pancreatobiliary probes. Multivariable logistic regression was used to estimate associations between clinical and pathology findings and results from FISH. The combination of FISH probes 1q21, 7p12, 8q24, and 9p21 identified cancer cells with 93% sensitivity and 100% specificity in pancreatobiliary tissue samples and were therefore included in the pancreatobiliary probe set. In the validation cohort of brush samples, pancreatobiliary FISH identified samples from patients with malignancy with a significantly higher level of sensitivity (64.7%) than the UroVysion probes (45.9%) (P < .001) or routine cytology analysis (18.8%) (P < .001), but similar specificity (92.9%, 90.8%, and 100.0% respectively). Factors significantly associated with detection of carcinoma, in adjusted analyses, included detection of polysomy by pancreatobiliary FISH (P < .001), a mass by cross-sectional imaging (P < .001), cancer cells by routine cytology (overall P = .003), as well as absence of primary sclerosing cholangitis (P = .011). We identified a set of FISH probes that detects cancer cells in pancreatobiliary brush samples from patients with and without primary sclerosing cholangitis with higher levels of sensitivity than UroVysion probes. Cytologic brushing test results and clinical features were independently associated with detection of cancer and might be used to identify patients with pancreatobiliary cancers. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Manufacture of thin-walled clad tubes by pressure welding of roll bonded sheets
NASA Astrophysics Data System (ADS)
Schmidt, Hans Christian; Grydin, Olexandr; Stolbchenko, Mykhailo; Homberg, Werner; Schaper, Mirko
2017-10-01
Clad tubes are commonly manufactured by fusion welding of roll bonded metal sheets or, mechanically, by hydroforming. In this work, a new approach towards the manufacture of thin-walled tubes with an outer diameter to wall thickness ratio of about 12 is investigated, involving the pressure welding of hot roll bonded aluminium-steel strips. By preparing non-welded edges during the roll bonding process, the strips can be zip-folded and (cold) pressure welded together. This process routine could be used to manufacture clad tubes in a continuous process. In order to investigate the process, sample tube sections with a wall thickness of 2.1 mm were manufactured by U-and O-bending from hot roll bonded aluminium-stainless steel strips. The forming and welding were carried out in a temperature range between RT and 400°C. It was found that, with the given geometry, a pressure weld is established at temperatures starting above 100°C. The tensile tests yield a maximum bond strength at 340°C. Micrograph images show a consistent weld of the aluminium layer over the whole tube section.
Chiereghin, Angela; Pavia, Claudia; Gabrielli, Liliana; Piccirilli, Giulia; Squarzoni, Diego; Turello, Gabriele; Gibertoni, Dino; Simonazzi, Giuliana; Capretti, Maria Grazia; Lanari, Marcello; Lazzarotto, Tiziana
2017-10-01
Clinical evaluation of the Elecsys ® CMV IgM, IgG, IgG Avidity and COBAS AmpliPrep/COBAS TaqMan CMV (COBAS CMV) assays (Roche Diagnostics AG) in the diagnosis and prognosis of congenital CMV infection was performed. In this study, 150 preselected clinical samples (50 primary infection sera, 50 amniotic fluid [AF] and 50 newborn urine) were processed using Roche serological/molecular CMV-specific tests. Results were compared with those obtained by routine assays (comparator assays). The Elecsys ® CMV IgM and IgG assays showed a perfect agreement (100%) with the comparator assays. Using the combination of the Elecsys ® CMV IgM and IgG Avidity assays results, a primary infection was identified in 100% of cases. Inappropriate avidity CMV IgG values in two samples with very low IgG values (<6 AU/mL) were observed. COBAS CMV assay showed an agreement equal to 98% and 100% with comparator assays by processing AF and urine samples, respectively. Among AF with quantitative results, Lin's concordance correlation was 0.933 and comparator-COBAS CMV assays gave CMV-DNA loads differing by <0.5 log 10 DNA. Finally, higher CMV-DNA levels in AF samples were associated with a symptomatic outcome (p=0.003). The Roche CMV-specific assays compared well with the comparator assays, thus providing to be suitable for clinical use. Copyright © 2017 Elsevier B.V. All rights reserved.
IDC Re-Engineering Phase 2 System Requirements Document Version 1.4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, James M.; Burns, John F.; Satpathi, Meara Allena
This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide data,more » but includes requirements for the dissemination of radionuclide data and products.« less
IDC Re-Engineering Phase 2 System Requirements Document V1.3.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, James M.; Burns, John F.; Satpathi, Meara Allena
2015-12-01
This System Requirements Document (SRD) defines waveform data processing requirements for the International Data Centre (IDC) of the Comprehensive Nuclear Test Ban Treaty Organization (CTBTO). The IDC applies, on a routine basis, automatic processing methods and interactive analysis to raw International Monitoring System (IMS) data in order to produce, archive, and distribute standard IDC products on behalf of all States Parties. The routine processing includes characterization of events with the objective of screening out events considered to be consistent with natural phenomena or non-nuclear, man-made phenomena. This document does not address requirements concerning acquisition, processing and analysis of radionuclide datamore » but includes requirements for the dissemination of radionuclide data and products.« less
NASA Astrophysics Data System (ADS)
Sweat, Joseph Allen
1999-11-01
The optical measurement of the orientational response of chemical functional groups of a polymer as it is subjected to conventional dynamic mechanical analysis can give insight into the rheological behavior of the polymer while under repetitive strain based on the chemical structure. Instrumentation used in the mid infrared has included the use of grating monochromators and interferometers. The use of a multiply modulated optical signal has decreased the level of noise to observe the small amplitude changes (typically >10-3 absorbance units) associated with the repetitive oscillatory strain. The use of digital signal processing to replace phase sensitive detection for demodulation of the optical signal has greatly reduced the spectral collection time. In addition, multiplexing gained with the use of step-scan interferometry in making time resolved measurements has aided in making the procedure more practical. However, instrumental complexity and expense are drawbacks. By incorporating the high throughput, polarized tuned beam, and rapid wavelength switching capability of an acousto-optic tunable filter (AOTF), a dynamic instrument with integrated centralized control by a single microprocessor has been built. it operates in the near infrared with a rapid dynamic data collection time and requires the use of only a single modulation in the form of the sample oscillatory strain. The near infrared permits thicker samples to reduce sample preparation tune or allows polymers to be tested without pretreatment. The use of Fourier based digital filtering improves the signal to noise ratio of the dynamic differential spectra. The instrument is cost effective and rugged in comparison to step-scan interferometers yet has a rapid data collection rate allowing use in a routine industrial setting. Information from these measurements can aid in determining the rheological properties necessary for the end use functionality of a polymer. Additionally, AOTF instrumentation can be used for static dichroic measurements of polymers for routine testing. An example of this is the routine measurement of the dichroic ratio of a natural protein biopolymer, wheat gluten (film), as an indication of the gluten strength. This type of measurement has the potential to be useful in the improvement of wheat varieties and in the indication of wheat quality for end use.
Bosco, Renato; Caser, Matteo; Vanara, Francesca; Scariot, Valentina
2013-11-20
Plant hormones play a crucial role in controlling plant growth and development. These groups of naturally occurring substances trigger physiological processes at very low concentrations, which mandate sensitive techniques for their quantitation. This paper describes a method to quantify endogenous (±)-2-cis-4-trans-abscisic acid, indole-3-acetic acid, indole-3-propionic acid, and indole-3-butyric acid. The method combines high-performance liquid chromatography (HPLC) with diode array and fluorescence detection in a single run. Hybrid tea rose 'Monferrato' matrices (leaves, petals, roots, seeds, androecium, gynoecium, and pollen) were used as references. Rose samples were separated and suspended in extracting methanol, after which (±)-2-cis-4-trans-abscisic acid and auxins were extracted by solvent extraction. Sample solutions were added first to cation solid phase extraction (SPE) cartridges and the eluates to anion SPE cartridges. The acidic hormones were bound to the last column and eluted with 5% phosphoric acid in methanol. Experimental results showed that this approach can be successfully applied to real samples and that sample preparation and total time for routine analysis can be greatly reduced.
Robert-Peillard, Fabien; Boudenne, Jean-Luc; Coulomb, Bruno
2014-05-01
This paper presents a simple, accurate and multi-sample method for the determination of proline in wines thanks to a 96-well microplate technique. Proline is the most abundant amino acid in wine and is an important parameter related to wine characteristics or maturation processes of grape. In the current study, an improved application of the general method based on sodium hypochlorite oxidation and o-phthaldialdehyde (OPA)-thiol spectrofluorometric detection is described. The main interfering compounds for specific proline detection in wines are strongly reduced by selective reaction with OPA in a preliminary step under well-defined pH conditions. Application of the protocol after a 500-fold dilution of wine samples provides a working range between 0.02 and 2.90gL(-1), with a limit of detection of 7.50mgL(-1). Comparison and validation on real wine samples by ion-exchange chromatography prove that this procedure yields accurate results. Simplicity of the protocol used, with no need for centrifugation or filtration, organic solvents or high temperature enables its full implementation in plastic microplates and efficient application for routine analysis of proline in wines. Copyright © 2013 Elsevier Ltd. All rights reserved.
Feedforward Self-Modeling Enhances Skill Acquisition in Children Learning Trampoline Skills
Ste-Marie, Diane M.; Vertes, Kelly; Rymal, Amanda M.; Martini, Rose
2011-01-01
The purpose of this research was to examine whether children would benefit from a feedforward self-modeling (FSM) video and to explore possible explanatory mechanisms for the potential benefits, using a self-regulation framework. To this end, children were involved in learning two five-skill trampoline routines. For one of the routines, a FSM video was provided during acquisition, whereas only verbal instructions were provided for the alternate routine. The FSM involved editing video footage such that it showed the learner performing the trampoline routine at a higher skill level than their current capability. Analyses of the data showed that while physical performance benefits were observed for the routine that was learned with the FSM video, no differences were obtained in relation to the self-regulatory measures. Thus, the FSM video enhanced motor skill acquisition, but this could not be explained by changes to the varied self-regulatory processes examined. PMID:21779270
Feedforward self-modeling enhances skill acquisition in children learning trampoline skills.
Ste-Marie, Diane M; Vertes, Kelly; Rymal, Amanda M; Martini, Rose
2011-01-01
The purpose of this research was to examine whether children would benefit from a feedforward self-modeling (FSM) video and to explore possible explanatory mechanisms for the potential benefits, using a self-regulation framework. To this end, children were involved in learning two five-skill trampoline routines. For one of the routines, a FSM video was provided during acquisition, whereas only verbal instructions were provided for the alternate routine. The FSM involved editing video footage such that it showed the learner performing the trampoline routine at a higher skill level than their current capability. Analyses of the data showed that while physical performance benefits were observed for the routine that was learned with the FSM video, no differences were obtained in relation to the self-regulatory measures. Thus, the FSM video enhanced motor skill acquisition, but this could not be explained by changes to the varied self-regulatory processes examined.
Amendola, Alessandra; Bloisi, Maria; Marsella, Patrizia; Sabatini, Rosella; Bibbò, Angela; Angeletti, Claudio; Capobianchi, Maria Rosaria
2011-09-01
Numerous studies investigating clinical significance of HIV-1 minimal residual viremia (MRV) suggest potential utility of assays more sensitive than those routinely used to monitor viral suppression. However currently available methods, based on different technologies, show great variation in detection limit and input plasma volume, and generally suffer from lack of standardization. In order to establish new tools suitable for routine quantification of minimal residual viremia in patients under virological suppression, some modifications were introduced into standard procedure of the Abbott RealTime HIV-1 assay leading to a "modified" and an "ultrasensitive" protocols. The following modifications were introduced: calibration curve extended towards low HIV-1 RNA concentration; 4 fold increased sample volume by concentrating starting material; reduced volume of internal control; adoption of "open-mode" software for quantification. Analytical performances were evaluated using the HIV-1 RNA Working Reagent 1 for NAT assays (NIBSC). Both tests were applied to clinical samples from virologically suppressed patients. The "modified" and the "ultrasensitive" configurations of the assay reached a limit of detection of 18.8 (95% CI: 11.1-51.0 cp/mL) and 4.8 cp/mL (95% CI: 2.6-9.1 cp/mL), respectively, with high precision and accuracy. In clinical samples from virologically suppressed patients, "modified" and "ultrasensitive" protocols allowed to detect and quantify HIV RNA in 12.7% and 46.6%, respectively, of samples resulted "not-detectable", and in 70.0% and 69.5%, respectively, of samples "detected <40 cp/mL" in the standard assay. The "modified" and "ultrasensitive" assays are precise and accurate, and easily adoptable in routine diagnostic laboratories for measuring MRV. Copyright © 2011 Elsevier B.V. All rights reserved.
Henriksen, Linda O; Faber, Nina R; Moller, Mette F; Nexo, Ebba; Hansen, Annebirthe B
2014-10-01
Suitable procedures for transport of blood samples from general practitioners to hospital laboratories are requested. Here we explore routine testing on samples stored and transported as whole blood in lithium-heparin or serum tubes. Blood samples were collected from 106 hospitalized patients, and analyzed on Architect c8000 or Advia Centaur XP for 35 analytes at base line, and after storage and transport of whole blood in lithium-heparin or serum tubes at 21 ± 1°C for 10 h. Bias and imprecision (representing variation from analysis and storage) were calculated from values at baseline and after storage, and differences tested by paired t-tests. Results were compared to goals set by the laboratory. We observed no statistically significant bias and results within the goal for imprecision between baseline samples and 10-h samples for albumin, alkaline phosphatase, antitrypsin, bilirubin, creatinine, free triiodothyronine, γ-glutamyl transferase, haptoglobin, immunoglobulin G, lactate dehydrogenase, prostate specific antigen, total carbon dioxide, and urea. Alanine aminotransferase, amylase, C-reactive protein, calcium, cholesterol, creatine kinase, ferritin, free thyroxine, immunoglobulin A, immunoglobulin M, orosomucoid, sodium, transferrin, and triglycerides met goals for imprecision, though they showed a minor, but statistically significant bias in results after storage. Cobalamin, folate, HDL-cholesterol, iron, phosphate, potassium, thyroid stimulating hormone and urate warranted concern, but only folate and phosphate showed deviations of clinical importance. We conclude that whole blood in lithium-heparin or serum tubes stored for 10 h at 21 ± 1°C, may be used for routine analysis without restrictions for all investigated analytes but folate and phosphate.
Fong, Sophia Yui Kau; Poulsen, Jessie; Brandl, Martin; Bauer-Brandl, Annette
2017-01-01
A novel microdialysis-dissolution/permeation (M-D/P) system was developed for the biopharmaceutical assessment of oral drug formulations. This system consists of a side-by-side diffusion chamber, a microdialysis unit fixed within the dissolution chamber for continuous sampling, and a biomimetic Permeapad® as the intestinal barrier. In the M-D/P system, the concentration of the molecularly dissolved drug (with MWCO <20kDa) was measured over time in the dissolution compartment (representing the gastrointestinal tract) while the concentration of the permeated drug was measured in the acceptor compartment (representing the blood). The kinetics of both the dissolution process and the permeation process were simultaneously quantified under circumstances that mimic physiological conditions. For the current proof-of-concept study, hydrocortisone (HCS) in the form of slowly dissolving solvate crystals and buffer and the biorelevant fasted state simulated intestinal fluids (FaSSIF), were employed as the model drug and dissolution media, respectively. The applicability of the M-D/P system to dissolution and permeation profiling of HCS in buffer and in FaSSIF has been successfully demonstrated. Compared to the conventional direct sampling method (using filter of 0.1-0.45μm), sampling by the M-D/P system exhibited distinct advantages, including (1) showing minimal disturbance of the permeation process, (2) differentiating "molecularly" dissolved drugs from "apparently" dissolved drugs during dissolution of HCS in FaSSIF, and (3) being less laborious and having better sampling temporal resolution. M-D/P system appeared to be a promising, simple and routine tool that allows for the researchers' intensive comprehension of the interplay of dissolution and permeation thus helping for better oral formulation screening and as an ultimate goal, for better dosage forms assessment. Copyright © 2016. Published by Elsevier B.V.