OpenSatKit Enables Quick Startup for CubeSat Missions
NASA Technical Reports Server (NTRS)
McComas, David; Melton, Ryan
2017-01-01
The software required to develop, integrate, and operate a spacecraft is substantial regardless of whether its a large or small satellite. Even getting started can be a monumental task. To solve this problem, NASAs Core Flight System (cFS), NASA's 42 spacecraft dynamics simulator, and Ball Aerospaces COSMOS ground system have been integrated together into a kit called OpenSatKit that provides a complete and open source software solution for starting a new satellite mission. Users can have a working system with flight software, dynamics simulation, and a ground command and control system up and running within hours.Every satellite mission requires three primary categories of software to function. The first is Flight Software (FSW) which provides the onboard control of the satellites and its payload(s). NASA's cFS provides a great platform for developing this software. Second, while developing a satellite on earth, it is necessary to simulate the satellites orbit, attitude, and actuators, to ensure that the systems that control these aspects will work correctly in the real environment. NASAs 42 simulator provides these functionalities. Finally, the ground has to be able to communicate with the satellite, monitor its performance and health, and display its data. Additionally, test scripts have to be written to verify the system on the ground. Ball Aerospace's COSMOS command and control system provides this functionality. Once the OpenSatKit is up and running, the next step is to customize the platform and get it running on the end target. Starting from a fully working system makes porting the cFS from Linux to a users platform much easier. An example Raspberry Pi target is included in the kit so users can gain experience working with a low cost hardware target. All users can benefit from OpenSatKit but the greatest impact and benefits will be to SmallSat missions with constrained budgets and small software teams. This paper describes OpenSatKits system design, the steps necessary to run the system to target the Raspberry Pi, and future plans. OpenSatKit is a free fully functional spacecraft software system that we hope will greatly benefit the SmallSat community.
Li, Jin-ming; Zheng, Huai-jing; Wang, Lu-nan; Deng, Wei
2003-04-01
To establish a model for one choosing controls with a suitable concentration for internal quality control (IQC) with qualitative ELISA detection, and a consecutive plotting method on Levey-Jennings control chart when reagent kit lot is changed. First, a series of control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg respectively were assessed for within-run and between-run precision according to NCCLs EP5 document. Then, a linear regression equation (y=bx + a) with best correlation coefficient (r > 0.99) was established based on S/CO values of the series of control serum. Finally, one could choose controls with S/CO value calculated from the equation (y = bx + a) minus the product of the S/CO value multiplying three-fold between-run CV to be still more than 1.0 for IQC use. For consecutive plotting on Levey-Jennings control chart when ELISA kit lot was changed, the new lot kits were used to detect the same series of HBsAg control serum as above. Then, a new linear regression equation (y2 = b2x2 + a2) with best correlation coefficient was obtained. The old one (y1 =b1x1 + a1) could be obtained based on the mean values from above precision assessment. The S/CO value of a control serum detected by new lot kit could be changed to that detected by old kit lot based on the factor of y2/y1. Therefore, the plotting on primary Levey-Jennings control chart could be continued. The within-run coefficient of variation CV of the ELISA method for control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg were 11.08%, 9.49%, 9.83%, 9.18% and 7.25%, respectively, and between-run CV were 13.25%, 14.03%, 15.11%, 13.29% and 9.92%. The linear regression equation with best correlation coefficient from a test at random was y = 3.509x + 0.180. The suitable concentration of control serum for IQC could be 0.5ng/ml or 1.0ng/ml. The linear regression equation from the old lot and other two new lots of the ELISA kits were y1 = 3.550(x1) + 0.226, y2 = 3.238(x2) +0.388, and y3 =3.428(x3) + 0.148, respectively. Then, the transferring factors of 0.960 (y2/y1) and 0.908 (y3/y1) were obtained. The results shows that the model established for IQC control serum concentration selecting and for consecutive plotting on control chart when the reagent lot is changed is effective and practical.
Buffer substitution in malaria rapid diagnostic tests causes false-positive results
2010-01-01
Background Malaria rapid diagnostic tests (RDTs) are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution) or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands) showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74%) RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20), and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs). Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness) of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results. PMID:20650003
NASA Astrophysics Data System (ADS)
Anisimov, D. N.; Dang, Thai Son; Banerjee, Santo; Mai, The Anh
2017-07-01
In this paper, an intelligent system use fuzzy-PD controller based on relation models is developed for a two-wheeled self-balancing robot. Scaling factors of the fuzzy-PD controller are optimized by a Cross-Entropy optimization method. A linear Quadratic Regulator is designed to bring a comparison with the fuzzy-PD controller by control quality parameters. The controllers are ported and run on STM32F4 Discovery Kit based on the real-time operating system. The experimental results indicate that the proposed fuzzy-PD controller runs exactly on embedded system and has desired performance in term of fast response, good balance and stabilize.
Central Mechanisms and Treatment of Blast-Induced Auditory and Vestibular Injuries
2018-01-01
Standards and control samples were run simultaneously for validation. Western blotting: Twenty micrograms of the protein extracts were fractionated by...removed after being administered with isoflurane and slice (400 µm) was cut in coronal section using a vibrating blade microtome (Leica VT1000S, Leica...P21958 (ThermoFisher scientific). The eluate was run to a SDS-PAGE gel and was silver stained using a complete kit (24600, ThermoFisher Scientific
30 CFR 7.405 - Critical characteristics.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Cable Splice Kits § 7.405 Critical characteristics. (a) A sample from each production run, batch, or lot of manufactured electric cable, signaling cable, or splice made from a splice kit shall be flame... cable or splice and a sample of the cable or splice kit assembly shall be visually inspected or tested...
30 CFR 7.405 - Critical characteristics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Cable Splice Kits § 7.405 Critical characteristics. (a) A sample from each production run, batch, or lot of manufactured electric cable, signaling cable, or splice made from a splice kit shall be flame... cable or splice and a sample of the cable or splice kit assembly shall be visually inspected or tested...
Kruk, Tamara; Ratnam, Sam; Preiksaitis, Jutta; Lau, Allan; Hatchette, Todd; Horsman, Greg; Van Caeseele, Paul; Timmons, Brian; Tipples, Graham
2012-10-01
We conducted a multicenter trial in Canada to assess the value of using trueness controls (TC) for rubella virus IgG and hepatitis B virus surface antibody (anti-HBs) serology to determine test performance across laboratories over time. TC were obtained from a single source with known international units. Seven laboratories using different test systems and kit lots included the TC in routine assay runs of the analytes. TC measurements of 1,095 rubella virus IgG and 1,195 anti-HBs runs were plotted on Levey-Jennings control charts for individual laboratories and analyzed using a multirule quality control (MQC) scheme as well as a single three-standard-deviation (3-SD) rule. All rubella virus IgG TC results were "in control" in only one of the seven laboratories. Among the rest, "out-of-control" results ranged from 5.6% to 10% with an outlier at 20.3% by MQC and from 1.1% to 5.6% with an outlier at 13.4% by the 3-SD rule. All anti-HBs TC results were "in control" in only two laboratories. Among the rest, "out-of-control" results ranged from 3.3% to 7.9% with an outlier at 19.8% by MQC and from 0% to 3.3% with an outlier at 10.5% by the 3-SD rule. In conclusion, through the continuous monitoring of assay performance using TC and quality control rules, our trial detected significant intra- and interlaboratory, test system, and kit lot variations for both analytes. In most cases the assay rejections could be attributable to the laboratories rather than to kit lots. This has implications for routine diagnostic screening and clinical practice guidelines and underscores the value of using an approach as described above for continuous quality improvement in result reporting and harmonization for these analytes.
StochKit2: software for discrete stochastic simulation of biochemical systems with events.
Sanft, Kevin R; Wu, Sheng; Roh, Min; Fu, Jin; Lim, Rone Kwei; Petzold, Linda R
2011-09-01
StochKit2 is the first major upgrade of the popular StochKit stochastic simulation software package. StochKit2 provides highly efficient implementations of several variants of Gillespie's stochastic simulation algorithm (SSA), and tau-leaping with automatic step size selection. StochKit2 features include automatic selection of the optimal SSA method based on model properties, event handling, and automatic parallelism on multicore architectures. The underlying structure of the code has been completely updated to provide a flexible framework for extending its functionality. StochKit2 runs on Linux/Unix, Mac OS X and Windows. It is freely available under GPL version 3 and can be downloaded from http://sourceforge.net/projects/stochkit/. petzold@engineering.ucsb.edu.
Increasing Flight Software Reuse with OpenSatKit
NASA Technical Reports Server (NTRS)
McComas, David C.
2018-01-01
In January 2015 the NASA Goddard Space Flight Center (GSFC) released the Core Flight System (cFS) as open source under the NASA Open Source Agreement (NOSA) license. The cFS is based on flight software (FSW) developed for 12 spacecraft spanning nearly two decades of effort and it can provide about a third of the FSW functionality for a low-earth orbiting scientific spacecraft. The cFS is a FSW framework that is portable, configurable, and extendable using a product line deployment model. However, the components are maintained separately so the user must configure, integrate, and deploy them as a cohesive functional system. This can be very challenging especially for organizations such as universities building cubesats that have minimal experience developing FSW. Supporting universities was one of the primary motivators for releasing the cFS under NOSA. This paper describes the OpenSatKit that was developed to address the cFS deployment challenges and to serve as a cFS training platform for new users. It provides a fully functional out-of-the box software system that includes NASA's cFS, Ball Aerospace's command and control system COSMOS, and a NASA dynamic simulator called 42. The kit is freely available since all of the components have been released as open source. The kit runs on a Linux platform, includes 8 cFS applications, several kit-specific applications, and built in demos illustrating how to use key application features. It also includes the software necessary to port the cFS to a Raspberry Pi and instructions for configuring COSMOS to communicate with the target. All of the demos and test scripts can be rerun unchanged with the cFS running on the Raspberry Pi. The cFS uses a 3-tiered layered architecture including a platform abstraction layer, a Core Flight Executive (cFE) middle layer, and an application layer. Similar to smart phones, the cFS application layer is the key architectural feature for users to extend the FSW functionality to meet their mission-specific requirements. The platform abstraction layer and the cFE layers go a step further than smart phones by providing a platform-agnostic Application Programmer Interface (API) that allows applications to run unchanged on different platforms. OpenSatKit can serve two significant architectural roles that will further help the adoption of the cFS and help create a community of users that can share assets. First, the kit is being enhanced to automate the integration of applications with the goal of creating a virtual cFS "App Store".. Second, a platform certification test suite can be developed that would allow users to verify the port of the cFS to a new platform. This paper will describe the current state of these efforts and future plans.
A Simple Vertical Slab Gel Electrophoresis Apparatus.
ERIC Educational Resources Information Center
Carter, J. B.; And Others
1983-01-01
Describes an inexpensive, easily constructed, and safe vertical slab gel kit used routinely for sodium dodecyl sulphate-polyacrylamide gel electrophoresis research and student experiments. Five kits are run from a single transformer. Because toxic solutions are used, students are given plastic gloves and closely supervised during laboratory…
Li, Peihua; Ye, Huiming; Liu, Jiangwu; Jin, Hongwei; Lin, Yongzhi; Yan, Shuidi; Yu, Yang; Gao, Lei; Xu, Feihai; Zhang, Zhongying
2018-01-01
Tumor marker carbohydrate antigen 15-3 (CA15-3) is used as a biomarker to aid to diagnose and monitor the prognosis of breast cancer patients. A new quantitative determination kit for CA15-3 with chemiluminescent assay was developed by Xiamen InnoDx Biotech Co., Ltd, China. Therefore, we conducted the report to evaluate the performance of the kit. According to the "Guiding principles on performance analysis of diagnostic reagents in vitro", the calibration curve, limit of detection, reportable range, accuracy, precision, anti-interference capability, cross-reaction and comparison by measuring EDTA plasma and serum were carried out. In addition, the kit was performed in parallel to electrochemiluminescence immunoassay kit (Roche) to analyze the correlation between the two kits. Regression equation of calibration curve of the kit was Y=0.7914X+4.1032 (R 2 =.990). Limit of detection was 0.0347 U/mL. The reportable range was 0.5-2400 U/mL. Recovery ratio was 100.0%-104.8%. Coefficient of variations (CVs) of within-run and between-run were 4.8%-7.6% and 5.8%-7.4% respectively. No remarkable interferences (all Bias% were less than ±10%) were detected when samples contained hemoglobin ≤183.8 μmol/L, bilirubin ≤340 μmol/L, triglyceride ≤18.1 mmol/L, or rheumatoid factor ≤400 U/mL. No cross-reaction was present in the kit. Moreover, compared with the results from electrochemiluminescence immunoassay kit (Roche) in 345 serum samples, there was a satisfied correlation coefficient of 0.977 (P<.01), and the kit was simultaneously fit for the detection of EDTA plasma and serum samples. The new kit validated satisfactorily, and it can be used for detecting CA15-3 in clinical practice. © 2017 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.
Software development kit for a compact cryo-refrigerator
NASA Astrophysics Data System (ADS)
Gardiner, J.; Hamilton, J.; Lawton, J.; Knight, K.; Wilson, A.; Spagna, S.
2017-12-01
This paper introduces a Software Development Kit (SDK) that enables the creation of custom software applications that automate the control of a cryo-refrigerator (Quantum Design model GA-1) in third party instruments. A remote interface allows real time tracking and logging of critical system diagnostics such as pressures, temperatures, valve states and run modes. The helium compressor scroll capsule speed and Gifford-McMahon (G-M) cold head speed can be manually adjusted over a serial communication line via a CAN interface. This configuration optimizes cooling power, while reducing wear on moving components thus extending service life. Additionally, a proportional speed control mode allows for automated throttling of speeds based on temperature or pressure feedback from a 3rd party device. Warm up and cool down modes allow 1st and 2nd stage temperatures to be adjusted without the use of external heaters.
Byers, Lauren Averett; Horn, Leora; Ghandi, Jitendra; Kloecker, Goetz; Owonikoko, Taofeek; Waqar, Saiama Naheed; Krzakowski, Maciej; Cardnell, Robert J.; Fujimoto, Junya; Taverna, Pietro; Azab, Mohammad; Camidge, David Ross
2017-01-01
Background Amuvatinib (MP-470) is a multi-targeted kinase inhibitor with potent activity against c-Kit, synergistic with DNA-damaging agents. We evaluated amuvatinib in combination with platinum-etoposide (EP) chemotherapy by objective response rate, survival, and tolerability in platinum-refractory small cell lung cancer (SCLC) patients. Methods This study used a Simon 2-stage design requiring ≥3 centrally confirmed responses in the first 21 subjects. Subjects received EP with 300 mg amuvatinib orally three times daily in cycles of 21 days. A three-day amuvatinib run-in period before EP occurred in Cycle 1. Subjects received the same EP chemotherapy regimen given prior to progression/relapse. Results Among 23 subjects treated, we observed four PRs (17.4%) per RECIST 1.1, only two of which were centrally confirmed (8.7%, response duration 119, 151 days). Three subjects (13%) had confirmed stable disease. c-Kit H-score was ≥100 in two subjects whose respective durations of disease control were 151 and 256 days. Conclusions The addition of amuvatinib to EP chemotherapy in unselected, platinum-refractory SCLC did not meet the primary endpoint of ≥3 confirmed responses in stage 1. However, high c-Kit expression in two subjects with durable disease control suggests the potential for further study of amuvatinib in SCLC patients with high c-Kit expression. PMID:29113403
Byers, Lauren Averett; Horn, Leora; Ghandi, Jitendra; Kloecker, Goetz; Owonikoko, Taofeek; Waqar, Saiama Naheed; Krzakowski, Maciej; Cardnell, Robert J; Fujimoto, Junya; Taverna, Pietro; Azab, Mohammad; Camidge, David Ross
2017-10-06
Amuvatinib (MP-470) is a multi-targeted kinase inhibitor with potent activity against c-Kit, synergistic with DNA-damaging agents. We evaluated amuvatinib in combination with platinum-etoposide (EP) chemotherapy by objective response rate, survival, and tolerability in platinum-refractory small cell lung cancer (SCLC) patients. This study used a Simon 2-stage design requiring ≥3 centrally confirmed responses in the first 21 subjects. Subjects received EP with 300 mg amuvatinib orally three times daily in cycles of 21 days. A three-day amuvatinib run-in period before EP occurred in Cycle 1. Subjects received the same EP chemotherapy regimen given prior to progression/relapse. Among 23 subjects treated, we observed four PRs (17.4%) per RECIST 1.1, only two of which were centrally confirmed (8.7%, response duration 119, 151 days). Three subjects (13%) had confirmed stable disease. c-Kit H-score was ≥100 in two subjects whose respective durations of disease control were 151 and 256 days. The addition of amuvatinib to EP chemotherapy in unselected, platinum-refractory SCLC did not meet the primary endpoint of ≥3 confirmed responses in stage 1. However, high c-Kit expression in two subjects with durable disease control suggests the potential for further study of amuvatinib in SCLC patients with high c-Kit expression.
Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong
2012-04-18
To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.
Increasing Flight Software Reuse with OpenSatKit
NASA Technical Reports Server (NTRS)
McComas, David
2018-01-01
In January 2015 the NASA Goddard Space Flight Center (GSFC) released the Core Flight System (cFS) as open source under the NASA Open Source Agreement (NOSA) license. The cFS is based on flight software (FSW) developed for 12 spacecraft spanning nearly two decades of effort and it can provide about a third of the FSW functionality for a low-earth orbiting scientific spacecraft. The cFS is a FSW framework that is portable, configurable, and extendable using a product line deployment model. However, the components are maintained separately so the user must configure, integrate, and deploy them as a cohesive functional system. This can be very challenging especially for organizations such as universities building cubesats that have minimal experience developing FSW. Supporting universities was one of the primary motivators for releasing the cFS under NOSA. This paper describes the OpenSatKit that was developed to address the cFS deployment challenges and to serve as a cFS training platform for new users. It provides a fully functional out-of-the box software system that includes NASA's cFS, Ball Aerospaceâ€"TM"s command and control system COSMOS, and a NASA dynamic simulator called 42. The kit is freely available since all of the components have been released as open source. The kit runs on a Linux platform, includes 8 cFS applications, several kit-specific applications, and built in demos illustrating how to use key application features. It also includes the software necessary to port the cFS to a Raspberry Pi and instructions for configuring COSMOS to communicate with the target. All of the demos and test scripts can be rerun unchanged with the cFS running on the Raspberry Pi. The cFS uses a 3-tiered layered architecture including a platform abstraction layer, a Core Flight Executive (cFE) middle layer, and an application layer. Similar to smart phones, the cFS application layer is the key architectural feature for userâ€"TM"s to extend the FSW functionality to meet their mission-specific requirements. The platform abstraction layer and the cFE layers go a step further than smart phones by providing a platform-agnostic Application Programmer Interface (API) that allows applications to run unchanged on different platforms. OpenSatKit can serve two significant architectural roles that will further help the adoption of the cFS and help create a community of users that can share assets. First, the kit is being enhanced to automate the integration of applications with the goal of creating a virtual cFS 'App Store'. Second, a platform certification test suite can be developed that would allow users to verify the port of the cFS to a new platform. This paper will describe the current state of these efforts and future plans.
Development and validation of an ELISA kit (YF MAC-HD) to detect IgM to yellow fever virus.
Basile, Alison Jane; Goodman, Christin; Horiuchi, Kalanthe; Laven, Janeen; Panella, Amanda J; Kosoy, Olga; Lanciotti, Robert S; Johnson, Barbara W
2015-12-01
Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas. Published by Elsevier B.V.
KiT: a MATLAB package for kinetochore tracking.
Armond, Jonathan W; Vladimirou, Elina; McAinsh, Andrew D; Burroughs, Nigel J
2016-06-15
During mitosis, chromosomes are attached to the mitotic spindle via large protein complexes called kinetochores. The motion of kinetochores throughout mitosis is intricate and automated quantitative tracking of their motion has already revealed many surprising facets of their behaviour. Here, we present 'KiT' (Kinetochore Tracking)-an easy-to-use, open-source software package for tracking kinetochores from live-cell fluorescent movies. KiT supports 2D, 3D and multi-colour movies, quantification of fluorescence, integrated deconvolution, parallel execution and multiple algorithms for particle localization. KiT is free, open-source software implemented in MATLAB and runs on all MATLAB supported platforms. KiT can be downloaded as a package from http://www.mechanochemistry.org/mcainsh/software.php The source repository is available at https://bitbucket.org/jarmond/kit and under continuing development. Supplementary data are available at Bioinformatics online. jonathan.armond@warwick.ac.uk. © The Author 2016. Published by Oxford University Press.
Women Shaping the Future. The Future of Work Discussion Kit.
ERIC Educational Resources Information Center
Pine, Janet; Jackson, Sue; MacNeill, Kate
Designed to inform and empower women to participate in debates and decisions about the future of work in Australia, this kit provides everything needed to run a discussion session on the future of work with women in the community. It consists of a guide for users, workshop guide, topic sheets, and background reading. The guide for users introduces…
Optimization Routine for Generating Medical Kits for Spaceflight Using the Integrated Medical Model
NASA Technical Reports Server (NTRS)
Graham, Kimberli; Myers, Jerry; Goodenow, Deb
2017-01-01
The Integrated Medical Model (IMM) is a MATLAB model that provides probabilistic assessment of the medical risk associated with human spaceflight missions.Different simulations or profiles can be run in which input conditions regarding both mission characteristics and crew characteristics may vary. For each simulation, the IMM records the total medical events that occur and “treats” each event with resources drawn from import scripts. IMM outputs include Total Medical Events (TME), Crew Health Index (CHI), probability of Evacuation (pEVAC), and probability of Loss of Crew Life (pLOCL).The Crew Health Index is determined by the amount of quality time lost (QTL). Previously, an optimization code was implemented in order to efficiently generate medical kits. The kits were optimized to have the greatest benefit possible, given amass and/or volume constraint. A 6-crew, 14-day lunar mission was chosen for the simulation and run through the IMM for 100,000 trials. A built-in MATLAB solver, mixed-integer linear programming, was used for the optimization routine. Kits were generated in 10% increments ranging from 10%-100% of the benefit constraints. Conditions wheremass alone was minimized, volume alone was minimized, and where mass and volume were minimizedjointly were tested.
DOE Office of Scientific and Technical Information (OSTI.GOV)
von Laszewski, G.; Foster, I.; Gawor, J.
In this paper we report on the features of the Java Commodity Grid Kit. The Java CoG Kit provides middleware for accessing Grid functionality from the Java framework. Java CoG Kit middleware is general enough to design a variety of advanced Grid applications with quite different user requirements. Access to the Grid is established via Globus protocols, allowing the Java CoG Kit to communicate also with the C Globus reference implementation. Thus, the Java CoG Kit provides Grid developers with the ability to utilize the Grid, as well as numerous additional libraries and frameworks developed by the Java community tomore » enable network, Internet, enterprise, and peer-to peer computing. A variety of projects have successfully used the client libraries of the Java CoG Kit to access Grids driven by the C Globus software. In this paper we also report on the efforts to develop server side Java CoG Kit components. As part of this research we have implemented a prototype pure Java resource management system that enables one to run Globus jobs on platforms on which a Java virtual machine is supported, including Windows NT machines.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
von Laszewski, G.; Gawor, J.; Lane, P.
In this paper we report on the features of the Java Commodity Grid Kit (Java CoG Kit). The Java CoG Kit provides middleware for accessing Grid functionality from the Java framework. Java CoG Kit middleware is general enough to design a variety of advanced Grid applications with quite different user requirements. Access to the Grid is established via Globus Toolkit protocols, allowing the Java CoG Kit to also communicate with the services distributed as part of the C Globus Toolkit reference implementation. Thus, the Java CoG Kit provides Grid developers with the ability to utilize the Grid, as well asmore » numerous additional libraries and frameworks developed by the Java community to enable network, Internet, enterprise and peer-to-peer computing. A variety of projects have successfully used the client libraries of the Java CoG Kit to access Grids driven by the C Globus Toolkit software. In this paper we also report on the efforts to develop serverside Java CoG Kit components. As part of this research we have implemented a prototype pure Java resource management system that enables one to run Grid jobs on platforms on which a Java virtual machine is supported, including Windows NT machines.« less
Automated homogeneous liposome immunoassay systems for anticonvulsant drugs.
Kubotsu, K; Goto, S; Fujita, M; Tuchiya, H; Kida, M; Takano, S; Matsuura, S; Sakurabayashi, I
1992-06-01
We developed automated homogeneous immunoassays, based on immunolysis of liposomes, for measuring phenytoin, phenobarbital, and carbamazepine from serum. Liposome lysis was detected spectrophotometrically from entrapped glucose-6-phosphate dehydrogenase activity. The procedure was fully automated on a routine automated clinical analyzer. Within-run, between-run, dilution, and recovery tests showed good accuracies and reproducibilities. Bilirubin, hemoglobin, triglycerides, and Intrafat did not affect assay results. The results obtained by liposome immunoassays for phenytoin, phenobarbital, and carbamazepine correlated well with those obtained by enzyme-multiplied immunoassay (Syva EMIT) kits (r = 0.995, 0.986, and 0.988, respectively) and fluorescence polarization immunoassay (Abbott TDx) kits (r = 0.990, 0.991, and 0.975, respectively). The proposed method should be useful for monitoring anticonvulsant drug concentrations in blood.
SensorKit: An End-to-End Solution for Environmental Sensor Networking
NASA Astrophysics Data System (ADS)
Silva, F.; Graham, E.; Deschon, A.; Lam, Y.; Goldman, J.; Wroclawski, J.; Kaiser, W.; Benzel, T.
2008-12-01
Modern day sensor network technology has shown great promise to transform environmental data collection. However, despite the promise, these systems have remained the purview of the engineers and computer scientists who design them rather than a useful tool for the environmental scientists who need them. SensorKit is conceived of as a way to make wireless sensor networks accessible to The People: it is an advanced, powerful tool for sensor data collection that does not require advanced technological know-how. We are aiming to make wireless sensor networks for environmental science as simple as setting up a standard home computer network by providing simple, tested configurations of commercially-available hardware, free and easy-to-use software, and step-by-step tutorials. We designed and built SensorKit using a simplicity-through-sophistication approach, supplying users a powerful sensor to database end-to-end system with a simple and intuitive user interface. Our objective in building SensorKit was to make the prospect of using environmental sensor networks as simple as possible. We built SensorKit from off the shelf hardware components, using the Compact RIO platform from National Instruments for data acquisition due to its modular architecture and flexibility to support a large number of sensor types. In SensorKit, we support various types of analog, digital and networked sensors. Our modular software architecture allows us to abstract sensor details and provide users a common way to acquire data and to command different types of sensors. SensorKit is built on top of the Sensor Processing and Acquisition Network (SPAN), a modular framework for acquiring data in the field, moving it reliably to the scientist institution, and storing it in an easily-accessible database. SPAN allows real-time access to the data in the field by providing various options for long haul communication, such as cellular and satellite links. Our system also features reliable data storage and transmission, using a custody transfer mechanism that ensures data is retained until successful delivery to the scientist can be confirmed. The ability for the scientist to communicate in real-time with the sensor network in the field enables remote sensor reconfiguration and system health and status monitoring. We use a spiral approach of design, test, deploy and revise, and, by going to the field frequently and getting feedback from field scientists, we have been able to include additional functionality that is useful to the scientist while ensuring SensorKit remains intuitive to operate. Users can configure, control, and monitor SensorKit using a number of tools we have developed. An intuitive user interface running on a desktop or laptop allows scientists to setup the system, add and configure sensors, and specify when and how the data will be collected. We also have a mobile version of our interface that runs on a PDA and lets scientists calibrate sensors and "tune" the system while in the field, allowing for data validation before leaving the field and returning to the research lab. SensorKit also features SensorBase, an intuitive user interface built on top of a standard SQL database, which allows scientists to store and share their data with other researchers. SensorKit has been used for diverse scientific applications and deployed throughout the world: from studying mercury cycling in rice paddies in China, to ecological research in the neotropical rainforests of Costa Rica, to monitoring the contamination of salt lakes in Argentina.
Performance evaluation of a chemiluminescence microparticle immunoassay for CK-MB.
Lin, Zhi-Yuan; Fang, Yi-Zhen; Jin, Hong-Wei; Lin, Hua-Yue; Dai, Zhang; Luo, Qing; Li, Hong-Wei; Lin, Yan-Ling; Huang, Shui-Zhen; Gao, Lei; Xu, Fei-Hai; Zhang, Zhong-Ying
2018-03-31
To verify and evaluate the performance characteristics of a creatine kinase phosphokinase isoenzymes MB (CK-MB) assay kit, which produced by Xiamen Innodx Biotech Co. Ltd. Evaluation was carried out according to "Guidelines for principle of analysis performance evaluation of in vitro diagnostic reagent." The performance parameters included detection limit, linearity range, reportable range, recovery test, precision verification, interference test, cross-reactivity, matrix effect, and method comparison. The detection limit was 0.1 ng/mL. The assay had clinical linearity over range of 0.1 ng/mL-500 ng/mL. Reportable range was from 0.1 ng/mL to 1000 ng/mL. The average percent of recovery was 99.66%. The coefficient of variation (CV) for within-run and between-run of low CK-MB sample was 5.55% and 6.16%, respectively. As for high-level sample, it was 7.88% and 7.80%. In medical decision level, the relative deviation (Bias) of all interference tests was lower than 15%. When the sample had mild-hemolysis; hemoglobin ≤15 g/L; triglyceride ≤17 mmol/L; bilirubin ≤427.5 μmol/L; rheumatoid factor ≤206U/mL, there was no significant interference to be found. Moreover, assay kit had no cross-reaction with CK-MM and CK-BB. At last, total diagnostic accuracy of kit was 93.24%, when compared with refer kit. Overall the results of the verification study indicated the performance of kit is met the requirements of the clinical test. © 2018 Wiley Periodicals, Inc.
Therapeutic drug monitoring of infliximab: performance evaluation of three commercial ELISA kits.
Schmitz, Ellen M H; van de Kerkhof, Daan; Hamann, Dörte; van Dongen, Joost L J; Kuijper, Philip H M; Brunsveld, Luc; Scharnhorst, Volkher; Broeren, Maarten A C
2016-07-01
Therapeutic drug monitoring (TDM) of infliximab (IFX, Remicade®) can aid to optimize therapy efficacy. Many assays are available for this purpose. However, a reference standard is lacking. Therefore, we evaluated the analytical performance, agreement and clinically relevant differences of three commercially available IFX ELISA kits on an automated processing system. The kits of Theradiag (Lisa Tracker Infliximab), Progenika (Promonitor IFX) and apDia (Infliximab ELISA) were implemented on an automated processing system. Imprecision was determined by triplicate measurements of patient samples on five days. Agreement was evaluated by analysis of 30 patient samples and four spiked samples by the selected ELISA kits and the in-house IFX ELISA of Sanquin Diagnostics (Amsterdam, The Netherlands). Therapeutic consequences were evaluated by dividing patients into four treatment groups using cut-off levels of 1, 3 and 7 μg/mL and determining assay concordance. Within-run and between-run imprecision were acceptable (≤12% and ≤17%, respectively) within the quantification range of the selected ELISA kits. The apDia assay had the best precision and agreement to target values. Statistically significant differences were found between all assays except between Sanquin Diagnostics and the Lisa Tracker assay. The Promonitor assay measured the lowest IFX concentrations, the apDia assay the highest. When patients were classified in four treatment categories, 70% concordance was achieved. Although all assays are suitable for TDM, significant differences were observed in both imprecision and agreement. Therapeutic consequences were acceptable when patients were divided in treatment categories, but this could be improved by assay standardization.
21 CFR 864.9650 - Quality control kit for blood banking reagents.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...
21 CFR 864.9650 - Quality control kit for blood banking reagents.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...
21 CFR 864.9650 - Quality control kit for blood banking reagents.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...
21 CFR 864.9650 - Quality control kit for blood banking reagents.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Quality control kit for blood banking reagents... Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a) Identification. A quality control kit for blood banking reagents is a device that consists of sera, cells...
... the crook of your elbow. Getting Your Supplies Ready To open a sterile pad or kit: Wash your hands with soap and running water for at least 1 minute. Wash the backs, palms, fingers, and between ...
XMOS XC-2 Development Board for Mechanical Control and Data Collection
NASA Technical Reports Server (NTRS)
Jarnot, Robert F.; Bowden, William J.
2011-01-01
The scanning microwave limb sounder (SMLS) will use technological improvements in low-noise mixers to provide precise data on the Earth s atmospheric composition with high spatial resolution. This project focuses on the design and implementation of a realtime control system needed for airborne engineering tests of the SMLS. The system must coordinate the actuation of optical components using four motors with encoder readback, while collecting synchronized telemetric data from a GPS receiver and 3-axis gyrometric system. A graphical user interface for testing the control system was also designed using Python. Although the system could have been implemented with an FPGA(fieldprogrammable gate array)-based setup, a processor development kit manufactured by XMOS was chosen. The XMOS architecture allows parallel execution of multiple tasks on separate threads, making it ideal for this application. It is easily programmed using XC (a subset of C). The necessary communication interfaces were implemented in software, including Ethernet, with significant cost and time reduction compared to an FPGA-based approach. A simple approach to control the chopper, calibration mirror, and gimbal for the airborne SMLS was needed. The XMOS board allows for multiple threads and real-time data acquisition. The XC-2 development kit is an attractive choice for synchronized, real-time, event-driven applications. The XMOS is based on the transputer microprocessor architecture developed for parallel computing, which is being revamped in this new platform. The XMOS device has multiple cores capable of running parallel applications on separate threads. The threads communicate with each other via user-defined channels capable of transmitting data within the device. XMOS provides a C-based development environment using XC, which eliminates the need for custom tool kits associated with FPGA programming. The XC-2 has four cores and necessary hardware for Ethernet I/O.
Qualitative and quantitative assessment of Illumina's forensic STR and SNP kits on MiSeq FGx™.
Sharma, Vishakha; Chow, Hoi Yan; Siegel, Donald; Wurmbach, Elisa
2017-01-01
Massively parallel sequencing (MPS) is a powerful tool transforming DNA analysis in multiple fields ranging from medicine, to environmental science, to evolutionary biology. In forensic applications, MPS offers the ability to significantly increase the discriminatory power of human identification as well as aid in mixture deconvolution. However, before the benefits of any new technology can be employed, a thorough evaluation of its quality, consistency, sensitivity, and specificity must be rigorously evaluated in order to gain a detailed understanding of the technique including sources of error, error rates, and other restrictions/limitations. This extensive study assessed the performance of Illumina's MiSeq FGx MPS system and ForenSeq™ kit in nine experimental runs including 314 reaction samples. In-depth data analysis evaluated the consequences of different assay conditions on test results. Variables included: sample numbers per run, targets per run, DNA input per sample, and replications. Results are presented as heat maps revealing patterns for each locus. Data analysis focused on read numbers (allele coverage), drop-outs, drop-ins, and sequence analysis. The study revealed that loci with high read numbers performed better and resulted in fewer drop-outs and well balanced heterozygous alleles. Several loci were prone to drop-outs which led to falsely typed homozygotes and therefore to genotype errors. Sequence analysis of allele drop-in typically revealed a single nucleotide change (deletion, insertion, or substitution). Analyses of sequences, no template controls, and spurious alleles suggest no contamination during library preparation, pooling, and sequencing, but indicate that sequencing or PCR errors may have occurred due to DNA polymerase infidelities. Finally, we found utilizing Illumina's FGx System at recommended conditions does not guarantee 100% outcomes for all samples tested, including the positive control, and required manual editing due to low read numbers and/or allele drop-in. These findings are important for progressing towards implementation of MPS in forensic DNA testing.
Elbeik, Tarek; Dalessandro, Ralph; Loftus, Richard A; Beringer, Scott
2007-11-01
Comparative cost models were developed to assess cost-per-reportable result and annual costs for HIV-1 and HCV bDNA and AmpliPrep/TaqMan Test (PCR). Model cost components included kit, disposables, platform and related equipment, equipment service plan, equipment maintenance, equipment footprint, waste and labor. Model assessment was most cost-effective when run by bDNA with 36 or more clinical samples and PCR with 30 or fewer clinical samples. Lower costs are attained with maximum samples (84-168) run daily. Highest cost contributors include kit, platform and PCR proprietary disposables. Understanding component costs and the most economic use of HIV-1 and HCV viral load will aid in attaining lowest costs through selection of the appropriate assay and effective negotiations.
Kim, Myeong Hee; Cha, Choong Hwan; An, Dongheui; Choi, Sung Eun; Oh, Heung Bum
2008-04-01
Hepatitis B virus (HBV) DNA quantification is necessary for starting and monitoring of antiviral therapy in patients with chronic hepatitis B. This study was intended to assess the clinical performance of Abbott RealTime HBV Quantification kit (Abbott Laboratories, USA). The performance was evaluated in terms of precision, linearity, detection sensitivity, cross-reactivity, and carry-over. A correlation with the Real-Q HBV Quantification kit (BioSewoom Inc., Korea) was also examined using serum samples from 64 patients diagnosed with chronic hepatitis B and underwent lamivudine therapy in Asan Medical Center. We verified the trueness of the system by comparing the outputs with the assigned values of the BBI panel (BBI Diagnostics, USA). Within-run and between-run coefficients of variation (CV) were 3.56-4.71% and 3.03-4.98%, respectively. Linearity was manifested ranging from 53 to 10(9)copies/mL and the detection sensitivity was verified to be 51 copies/mL. None of hepatitis C virus showed cross-reactivity. No cross-contamination occurred when negative and positive samples were alternatively placed in a row. It showed a good correlation with the Real-Q HBV (r(2)=0.9609) and the test results for the BBI panel were also well agreed to the assigned values (r(2)=0.9933). The performance of Abbott RealTime HBV Quantification kit was excellent; thus, it should be widely used in starting and monitoring of antiviral therapy in Korean patients with chronic hepatitis B.
Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah
2005-01-01
Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.
Athanasiou, Labrini V; Petanides, Theodoros A; Chatzis, Manolis K; Kasabalis, Dimitrios; Apostolidis, Kosmas N; Saridomichelakis, Manolis N
2014-03-01
Antibodies against Leishmania spp. are detected in most dogs with clinical signs of leishmaniasis due to Leishmania infantum. Accurate, rapid in-clinic serological tests may permit immediate confirmation of the diagnosis and implementation of therapeutic measures. The aim of the current study was to evaluate the diagnostic accuracy of 2 commercial, rapid in-clinic serological tests for the detection of anti-Leishmania antibodies in sera of dogs, the Snap Canine Leishmania Antibody Test kit (IDEXX Laboratories Inc., Westbrook, Maine) and the ImmunoRun Antibody Detection kit (Biogal Galed Labs, Kibbutz Galed, Israel), using indirect fluorescent antibody test (IFAT) as the reference method. A total of 109 sera collected from 65 seropositive and 44 seronegative dogs were used. The sensitivities of the Snap and ImmunoRun kits were 89.23% (95% confidence interval: 79.05-95.54%) and 86.15% (95% confidence interval: 75.33-93.45%), respectively, and the specificity of both tests was 100%. A good agreement between each of the rapid in-clinic serological tests and IFAT and between the 2 rapid in-clinic serological tests was witnessed. Both rapid in-clinic serological tests showed an adequate diagnostic accuracy and can be used for the fast detection of antibodies against L. infantum in dogs.
cAMP levels in fast- and slow-twitch skeletal muscle after an acute bout of aerobic exercise
NASA Technical Reports Server (NTRS)
Sheldon, A.; Booth, F. W.; Kirby, C. R.
1993-01-01
The present study examined whether exercise duration was associated with elevated and/or sustained elevations of postexercise adenosine 3',5'-cyclic monophosphate (cAMP) by measuring cAMP levels in skeletal muscle for up to 4 h after acute exercise bouts of durations that are known to either produce (60 min) or not produce (10 min) mitochondrial proliferation after chronic training. Treadmill-acclimatized, but untrained, rats were run at 22 m/min for 0 (control), 10, or 60 min and were killed at various postexercise (0, 0.5, 1, 2, and 4 h) time points. Fast-twitch white and red (quadriceps) and slow-twitch (soleus) muscles were quickly excised, frozen in liquid nitrogen, and assayed for cAMP with a commercial kit. Unexpectedly, cAMP contents in all three muscles were similar to control (nonexercise) at most (21 of 30) time points after a single 10- or 60-min run. Values at 9 of 30 time points were significantly different from control (P < 0.05); i.e., 3 time points were significantly higher than control and 6 were significantly less than control. These data suggest that the cAMP concentration of untrained skeletal muscle after a single bout of endurance-type exercise is not, by itself, associated with exercise duration.
Serials Control and Deselection Projects. SPEC Kit 147.
ERIC Educational Resources Information Center
Association of Research Libraries, Washington, DC. Office of Management Studies.
This Systems and Procedures Exchange Center (SPEC) Kit on serials control and deselection projects provides a timely review of the efforts of research libraries to control the increasing costs of serial subscriptions. This kit contains documents from 13 libraries: University of California at Los Angeles and Riverside; Universities of Florida,…
21 CFR 864.9650 - Quality control kit for blood banking reagents.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for blood banking reagents... SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Products Used In Establishments That Manufacture Blood and Blood Products § 864.9650 Quality control kit for blood banking reagents. (a...
Find a Radon Test Kit or Measurement and Mitigation Professional
Find a qualified radon service professional to fix or mitigate your home. If you have questions about a radon, you should contact your state radon contact and/or contact one or both of the two privately-run National Radon Proficiency Programs
CSF biomarker variability in the Alzheimer’s Association quality control program
Mattsson, Niklas; Andreasson, Ulf; Persson, Staffan; Carrillo, Maria C.; Collins, Steven; Chalbot, Sonia; Cutler, Neal; Dufour-Rainfray, Diane; Fagan, Anne M.; Heegaard, Niels H. H.; Hsiung, Ging-Yuek Robin; Hyman, Bradley; Iqbal, Khalid; Lachno, D. Richard; Lleó, Alberto; Lewczuk, Piotr; Molinuevo, José L.; Parchi, Piero; Regeniter, Axel; Rissman, Robert; Rosenmann, Hanna; Sancesario, Giuseppe; Schröder, Johannes; Shaw, Leslie M.; Teunissen, Charlotte E.; Trojanowski, John Q.; Vanderstichele, Hugo; Vandijck, Manu; Verbeek, Marcel M.; Zetterberg, Henrik; Blennow, Kaj; Käser, Stephan A.
2013-01-01
Background The cerebrospinal fluid (CSF) biomarkers amyloid beta 1–42, total tau, and phosphorylated tau are used increasingly for Alzheimer’s disease (AD) research and patient management. However, there are large variations in biomarker measurements among and within laboratories. Methods Data from the first nine rounds of the Alzheimer’s Association quality control program was used to define the extent and sources of analytical variability. In each round, three CSF samples prepared at the Clinical Neurochemistry Laboratory (Mölndal, Sweden) were analyzed by single-analyte enzyme-linked immunosorbent assay (ELISA), a multiplexing xMAP assay, or an immunoassay with electrochemoluminescence detection. Results A total of 84 laboratories participated. Coefficients of variation (CVs) between laboratories were around 20% to 30%; within-run CVs, less than 5% to 10%; and longitudinal within-laboratory CVs, 5% to 19%. Interestingly, longitudinal within-laboratory CV differed between biomarkers at individual laboratories, suggesting that a component of it was assay dependent. Variability between kit lots and between laboratories both had a major influence on amyloid beta 1–42 measurements, but for total tau and phosphorylated tau, between-kit lot effects were much less than between-laboratory effects. Despite the measurement variability, the between-laboratory consistency in classification of samples (using prehoc-derived cutoffs for AD) was high (>90% in 15 of 18 samples for ELISA and in 12 of 18 samples for xMAP). Conclusions The overall variability remains too high to allow assignment of universal biomarker cutoff values for a specific intended use. Each laboratory must ensure longitudinal stability in its measurements and use internally qualified cutoff levels. Further standardization of laboratory procedures and improvement of kit performance will likely increase the usefulness of CSF AD biomarkers for researchers and clinicians. PMID:23622690
Kang, Keren; Dzakah, Emmanuel E; Huang, Yongping; Xie, Mingquan; Luo, Xiaochun; Li, Wenmei; Wang, Jihua
2015-05-30
The low sensitivity and specificity of Plasmodium falciparum diagnostic tests pose a serious health threat to people living in endemic areas. The objective of the study was to develop a rapid assay for the detection of histidine-rich protein 2 (HRP2) of P. falciparum in whole blood by immunofluorescence chromatographic technology. A total of 1163 positive and negative blood samples were screened. The double-antibody sandwich assay was used to establish the kit and its performance was evaluated for sensitivity, specificity, accuracy, precision, stability, and clinical effectiveness. The cut-off level of detection of the kit was 25 parasites/μl. Common interfering substances in human blood specimens, such as bilirubin, triglyceride and cholesterol had no significant effect on HRP2 antigen detection. The precision of the kit was run with different concentration of standard calibrators and the values were less than 10 %. The performance of this diagnostic kit in the detection of the calibrators has shown that a shelf life of about 12 months gives a more reliable result. Among clinical samples tested, the HRP2 test kit and the reference products had good coincidence rate in a parallel experiment and this test kit had a more sensitive detecting level to the target protein than the reference kits used in this study. The specificity and sensitivity for this test were 99.6 % (800/803) and 99.7 % (1160/1163), respectively. A novel HRP2 immunofluorescence detection method was developed in this study. Overall performance evaluation indicated that the kit has a rapid, high sensitivity and on-spot method for detecting P. falciparum.
46 CFR 184.710 - First-aid kits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...
46 CFR 184.710 - First-aid kits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...
46 CFR 184.710 - First-aid kits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...
46 CFR 184.710 - First-aid kits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...
46 CFR 184.710 - First-aid kits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...
Chen, Evan C; Karl, Taylor A; Kalisky, Tomer; Gupta, Santosh K; O'Brien, Catherine A; Longacre, Teri A; van de Rijn, Matt; Quake, Stephen R; Clarke, Michael F; Rothenberg, Michael E
2015-09-01
Receptor tyrosine kinase (RTK) inhibitors have advanced colon cancer treatment. We investigated the role of the RTK KIT in development of human colon cancer. An array of 137 patient-derived colon tumors and their associated xenografts were analyzed by immunohistochemistry to measure levels of KIT and its ligand KITLG. KIT and/or KITLG was stably knocked down by expression of small hairpin RNAs from lentiviral vectors in DLD1, HT29, LS174T, and COLO320 DM colon cancer cell lines, and in UM-COLON#8 and POP77 xenografts; cells transduced with only vector were used as controls. Cells were analyzed by real-time quantitative reverse transcription polymerase chain reaction, single-cell gene expression analysis, flow cytometry, and immunohistochemical, immunoblot, and functional assays. Xenograft tumors were grown from control and KIT-knockdown DLD1 and UM-COLON#8 cells in immunocompromised mice and compared. Some mice were given the RTK inhibitor imatinib after injection of cancer cells; tumor growth was measured based on bioluminescence. We assessed tumorigenicity using limiting dilution analysis. KIT and KITLG were expressed heterogeneously by a subset of human colon tumors. Knockdown of KIT decreased proliferation of colon cancer cell lines and growth of xenograft tumors in mice compared with control cells. KIT knockdown cells had increased expression of enterocyte markers, decreased expression of cycling genes, and, unexpectedly, increased expression of LGR5 associated genes. No activating mutations in KIT were detected in DLD1, POP77, or UM-COLON#8 cells. However, KITLG-knockdown DLD1 cells formed smaller xenograft tumors than control cells. Gene expression analysis of single CD44(+) cells indicated that KIT can promote growth via KITLG autocrine and/or paracrine signaling. Imatinib inhibited growth of KIT(+) colon cancer organoids in culture and growth of xenograft tumors in mice. Cancer cells with endogenous KIT expression were more tumorigenic in mice. KIT and KITLG are expressed by a subset of human colon tumors. KIT signaling promotes growth of colon cancer cells and organoids in culture and xenograft tumors in mice via its ligand, KITLG, in an autocrine or paracrine manner. Patients with KIT-expressing colon tumors can benefit from KIT RTK inhibitors. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
Chen, Evan C.; Karl, Taylor A.; Kalisky, Tomer; Gupta, Santosh K.; O’Brien, Catherine A.; Longacre, Teri A.; van de Rijn, Matt; Quake, Stephen R.; Clarke, Michael F.; Rothenberg, Michael E.
2015-01-01
Background & Aims Receptor tyrosine kinase (RTK) inhibitors have advanced colon cancer treatment. We investigated the role of the RTK KIT in development of human colon cancer. Methods An array of 137 patient-derived colon tumors and their associated xenografts were analyzed by immunohistochemistry to measure levels of KIT and its ligand KITLG. KIT and/or KITLG was stably knocked down by expression of small hairpin RNAs from lentiviral vectors in DLD1, HT29, LS174T, and COLO320 colon cancer cell lines, and in UM-COLON#8 and POP77 xenografts; cells transduced with only vector were used as controls. Cells were analyzed by real-time quantitative reverse transcription PCR, single-cell gene expression analysis, flow cytometry, and immunohistochemical, immunoblot, and functional assays. Xenograft tumors were grown from control and KIT-knockdown DLD1 and UM-COLON#8 cells in immunocompromised mice and compared. Some mice were given the RTK inhibitor imatinib following injection of cancer cells; tumor growth was measured based on bioluminescence. We assessed tumorigenicity using limiting dilution analysis. Results KIT and KITLG were expressed heterogeneously by a subset of human colon tumors. Knockdown of KIT decreased proliferation of colon cancer cell lines and growth of xenograft tumors in mice, compared with control cells. KIT knockdown cells had increased expression of enterocyte markers, decreased expression of cycling genes, and, unexpectedly, increased expression of LGR5-associated genes. No activating mutations in KIT were detected in DLD1, POP77, or UM-COLON#8 cell lines. However, KITLG-knockdown DLD1 cells formed smaller xenograft tumors than control cells. Gene expression analysis of single CD44+ cells indicated that KIT may promote growth via KITLG autocrine and/or paracrine signaling. Imatinib inhibited growth of KIT+ colon cancer organoids in culture and growth of xenograft tumors in mice. Cancer cells with endogenous KIT expression were more tumorigenic in mice. Conclusions KIT and KITLG are expressed by a subset of human colon tumors. KIT signaling promotes growth of colon cancer cells and organoids in culture and xenograft tumors in mice via its ligand, KITLG, in an autocrine or paracrine manner. Patients with KIT-expressing colon tumors may benefit from KIT RTK inhibitors. PMID:26026391
LogiKit - assisting complex logic specification and implementation for embedded control systems
NASA Astrophysics Data System (ADS)
Diglio, A.; Nicolodi, B.
2002-07-01
LogiKit provides an overall lifecycle solution. LogiKit is a powerful software engineering case toolkit for requirements specification, simulation and documentation. LogiKit also provides an automatic ADA software design, code and unit test generator.
Modular Mount Control System for Telescopes
NASA Astrophysics Data System (ADS)
Mooney, J.; Cleis, R.; Kyono, T.; Edwards, M.
The Space Observatory Control Kit (SpOCK) is the hardware, computers and software used to run small and large telescopes in the RDS division of the Air Force Research Laboratories (AFRL). The system is used to track earth satellites, celestial objects, terrestrial objects and aerial objects. The system will track general targets when provided with state vectors in one of five coordinate systems. Client-toserver and server-to-gimbals communication occurs via human-readable s-expressions that may be evaluated by the computer language called Racket. Software verification is achieved by scripts that exercise these expressions by sending them to the server, and receiving the expressions that the server evaluates. This paper describes the adaptation of a modular mount control system developed primarily for LEO satellite imaging on large and small portable AFRL telescopes with a goal of orbit determination and the generation of satellite metrics.
NASA Technical Reports Server (NTRS)
Schneider, Michelle
2003-01-01
This viewgraph representation provides an overview of the Telescience Resource Kit. The Telescience Resource Kit is a pc-based telemetry and command system that will be used by scientists and engineers to monitor and control experiments located on-board the International Space Station (ISS). Topics covered include: ISS Payload Telemetry and Command Flow, kit computer applications, kit telemetry capabilities, command capabilities, and training/testing capabilities.
Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P
2016-01-01
The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%), followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%). The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.
Accuracy of user-friendly blood typing kits tested under simulated military field conditions.
Bienek, Diane R; Charlton, David G
2011-04-01
Rapid user-friendly ABO-Rh blood typing kits (Eldon Home Kit 2511, ABO-Rh Combination Blood Typing Experiment Kit) were evaluated to determine their accuracy when used under simulated military field conditions and after long-term storage at various temperatures and humidities. Rates of positive tests between control groups, experimental groups, and industry standards were measured and analyzed using the Fisher's exact chi-square method to identify significant differences (p < or = 0.05). When Eldon Home Kits 2511 were used in various operational conditions, the results were comparable to those obtained with the control group and with the industry standard. The performance of the ABO-Rh Combination Blood Typing Experiment Kit was adversely affected by prolonged storage in temperatures above 37 degrees C. The diagnostic performance of commercial blood typing kits varies according to product and environmental storage conditions.
Activities of the Korean Institute of Tuberculosis
Ryoo, Sungweon; Kim, Hee Jin
2014-01-01
The Korean National Tuberculosis Association (KNTA) set up the Korean Institute of Tuberculosis (KIT) in 1970 to foster research and technical activities pertaining to tuberculosis (TB). The KNTA/KIT had successfully conducted a countrywide TB prevalence survey from 1965 to 1995 at 5-year intervals. The survey results (decline in TB rates) established Korea as a country that had successfully implemented national control programs for TB. The KIT developed the Korea Tuberculosis Surveillance System and the Laboratory Management Information System, both of which were transferred to the Korea Centers for Disease Control and Prevention after its establishment. The KIT functions as a central and supranational reference TB laboratory for microbiological and epidemiological research and provides training and education for health-care workers and medical practitioners. Recently, the KIT has expanded its activities to countries such as Ethiopia, Laos, and Timor-Leste to support TB control and prevention. The KIT will continue to support research activities and provide technical assistance in diagnosing the infection until it is completely eliminated in Korea. PMID:25861580
46 CFR 169.725 - First aid kit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...
46 CFR 169.725 - First aid kit.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...
46 CFR 169.725 - First aid kit.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...
46 CFR 169.725 - First aid kit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...
46 CFR 169.725 - First aid kit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...
Takahashi, Toshiaki; Friedmacher, Florian; Zimmer, Julia; Puri, Prem
2016-05-01
Persistent pulmonary hypertension(PPH) in congenital diaphragmatic hernia (CDH) is caused by increased vascular cell proliferation and endothelial cell (EC) dysfunction, thus leading to obstructive changes in the pulmonary vasculature. C-Kit and its ligand, stem cell factor(SCF), are expressed by ECs in the developing lung mesenchyme, suggesting an important role during lung vascular formation. Conversely, absence of c-Kit expression has been demonstrated in ECs of dysplastic alveolar capillaries. We hypothesized that c-Kit and SCF expression is increased in the pulmonary vasculature of nitrofen-induced CDH. Timed-pregnant rats received nitrofen or vehicle on gestational day 9(D9). Fetuses were sacrificed on D15, D18, and D21, and divided into control and CDH group. Pulmonary gene expression levels of c-Kit and SCF were analyzed by qRT-PCR. Immunofluorescence double staining for c-Kit and SCF was combined with CD34 to evaluate protein expression in ECs of the pulmonary vasculature. Relative mRNA levels of c-Kit and SCF were significantly increased in lungs of CDH fetuses on D15, D18, and D21 compared to controls. Confocal laser scanning microscopy confirmed markedly increased vascular c-Kit and SCF expression in mesenchymal ECs of CDH lungs on D15, D18, and D21 compared to controls. Increased expression of c-Kit and SCF in the pulmonary vasculature of nitrofen-induced CDH lungs suggest that increased c-Kit signaling during lung vascular formation may contribute to vascular remodeling and thus to PPH. Copyright © 2016 Elsevier Inc. All rights reserved.
c-Kit modifies the inflammatory status of smooth muscle cells
Song, Lei; Martinez, Laisel; Zigmond, Zachary M.; Hernandez, Diana R.; Lassance-Soares, Roberta M.; Selman, Guillermo
2017-01-01
Background c-Kit is a receptor tyrosine kinase present in multiple cell types, including vascular smooth muscle cells (SMC). However, little is known about how c-Kit influences SMC biology and vascular pathogenesis. Methods High-throughput microarray assays and in silico pathway analysis were used to identify differentially expressed genes between primary c-Kit deficient (KitW/W–v) and control (Kit+/+) SMC. Quantitative real-time RT-PCR and functional assays further confirmed the differences in gene expression and pro-inflammatory pathway regulation between both SMC populations. Results The microarray analysis revealed elevated NF-κB gene expression secondary to the loss of c-Kit that affects both the canonical and alternative NF-κB pathways. Upon stimulation with an oxidized phospholipid as pro-inflammatory agent, c-Kit deficient SMC displayed enhanced NF-κB transcriptional activity, higher phosphorylated/total p65 ratio, and increased protein expression of NF-κB regulated pro-inflammatory mediators with respect to cells from control mice. The pro-inflammatory phenotype of mutant cells was ameliorated after restoring c-Kit activity using lentiviral transduction. Functional assays further demonstrated that c-Kit suppresses NF-κB activity in SMC in a TGFβ-activated kinase 1 (TAK1) and Nemo-like kinase (NLK) dependent manner. Discussion Our study suggests a novel mechanism by which c-Kit suppresses NF-κB regulated pathways in SMC to prevent their pro-inflammatory transformation. PMID:28626608
c-Kit modifies the inflammatory status of smooth muscle cells.
Song, Lei; Martinez, Laisel; Zigmond, Zachary M; Hernandez, Diana R; Lassance-Soares, Roberta M; Selman, Guillermo; Vazquez-Padron, Roberto I
2017-01-01
c-Kit is a receptor tyrosine kinase present in multiple cell types, including vascular smooth muscle cells (SMC). However, little is known about how c-Kit influences SMC biology and vascular pathogenesis. High-throughput microarray assays and in silico pathway analysis were used to identify differentially expressed genes between primary c-Kit deficient (Kit W/W-v ) and control (Kit +/+ ) SMC. Quantitative real-time RT-PCR and functional assays further confirmed the differences in gene expression and pro-inflammatory pathway regulation between both SMC populations. The microarray analysis revealed elevated NF-κB gene expression secondary to the loss of c-Kit that affects both the canonical and alternative NF-κB pathways. Upon stimulation with an oxidized phospholipid as pro-inflammatory agent, c-Kit deficient SMC displayed enhanced NF-κB transcriptional activity, higher phosphorylated/total p65 ratio, and increased protein expression of NF-κB regulated pro-inflammatory mediators with respect to cells from control mice. The pro-inflammatory phenotype of mutant cells was ameliorated after restoring c-Kit activity using lentiviral transduction. Functional assays further demonstrated that c-Kit suppresses NF-κB activity in SMC in a TGFβ-activated kinase 1 (TAK1) and Nemo-like kinase (NLK) dependent manner. Our study suggests a novel mechanism by which c-Kit suppresses NF-κB regulated pathways in SMC to prevent their pro-inflammatory transformation.
Zakharova, Liudmila; Nural-Guvener, Hikmet; Feehery, Lorraine; Popovic-Sljukic, Snjezana
2015-01-01
Cardiac c-Kit+ cells have a modest cardiogenic potential that could limit their efficacy in heart disease treatment. The present study was designed to augment the cardiogenic potential of cardiac c-Kit+ cells through class I histone deacetylase (HDAC) inhibition and evaluate their therapeutic potency in the chronic heart failure (CHF) animal model. Myocardial infarction (MI) was created by coronary artery occlusion in rats. c-Kit+ cells were treated with mocetinostat (MOCE), a specific class I HDAC inhibitor. At 3 weeks after MI, CHF animals were retrogradely infused with untreated (control) or MOCE-treated c-Kit+ cells (MOCE/c-Kit+ cells) and evaluated at 3 weeks after cell infusion. We found that class I HDAC inhibition in c-Kit+ cells elevated the level of acetylated histone H3 (AcH3) and increased AcH3 levels in the promoter regions of pluripotent and cardiac-specific genes. Epigenetic changes were accompanied by increased expression of cardiac-specific markers. Transplantation of CHF rats with either control or MOCE/c-Kit+ cells resulted in an improvement in cardiac function, retardation of CHF remodeling made evident by increased vascularization and scar size, and cardiomyocyte hypertrophy reduction. Compared with CHF infused with control cells, infusion of MOCE/c-Kit+ cells resulted in a further reduction in left ventricle end-diastolic pressure and total collagen and an increase in interleukin-6 expression. The low engraftment of infused cells suggests that paracrine effects might account for the beneficial effects of c-Kit+ cells in CHF. In conclusion, selective inhibition of class I HDACs induced expression of cardiac markers in c-Kit+ cells and partially augmented the efficacy of these cells for CHF repair. Significance The study has shown that selective class 1 histone deacetylase inhibition is sufficient to redirect c-Kit+ cells toward a cardiac fate. Epigenetically modified c-Kit+ cells improved contractile function and retarded remodeling of the congestive heart failure heart. This study provides new insights into the efficacy of cardiac c-Kit+ cells in the ischemic heart failure model. PMID:26240433
15 CFR 742.2 - Proliferation of chemical and biological weapons.
Code of Federal Regulations, 2011 CFR
2011-01-01
... medical, analytical, diagnostic, and food testing kits that consist of pre-packaged materials of defined... health purposes: (1) Test kits containing no more than 300 grams of any chemical controlled by ECCN 1C350... part 745 of the EAR). Such test kits are controlled by ECCN 1C395 for CB and CW reasons, to States not...
15 CFR 742.2 - Proliferation of chemical and biological weapons.
Code of Federal Regulations, 2013 CFR
2013-01-01
... medical, analytical, diagnostic, and food testing kits that consist of pre-packaged materials of defined... health purposes: (1) Test kits containing no more than 300 grams of any chemical controlled by ECCN 1C350... part 745 of the EAR). Such test kits are controlled by ECCN 1C395 for CB and CW reasons, to States not...
15 CFR 742.2 - Proliferation of chemical and biological weapons.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., analytical, diagnostic, and food testing kits that consist of pre-packaged materials of defined composition... purposes: (1) Test kits containing no more than 300 grams of any chemical controlled by ECCN 1C350.b or .c... the EAR). Such test kits are controlled by ECCN 1C395 for CB and CW reasons, to States not Party to...
Jin, Huang; Chun-Lian, Tang; Zu-Wu, Tu; Li, Tang; Ke-Hui, Zhang; Qian, Li; Jun, Ye
2018-04-18
To prepare freeze-drying control materials of IgG antibody against Schistosoma japonicum for detection kits. The serum samples of schistosomiasis patients from endemic areas and normal people without history of schistosome infection or contact with infested water in Hubei Province were collected. All the sera were detected by the method approved by China Food and Drug Administration and selected for preparation of quality control samples. Totally twelve positive quality control materials, ten negative quality control materials, and one sensitive and one precision quality control materials were screened. According to the positive serum level, the positive degrees of quality control materials were divided into strong, medium and weak levels. The stability could be valid for one year. The freeze-drying quality control materials of IgG antibody against S. japonicum for detection kits are prepared. They are easy to use and have good stability, and therefore, they may meet the requirement of quality control for the detection of schistosomiasis diagnostics kits.
Directional and Attitude Stability Control Kit
2014-07-01
Pre-MRAP Vehicle Rollover Stats1 7/6/2014 DASK - Directional and Attitude Stability Control Kit 7 1: Joint Military Vehicle Working Group Army... contained in this report are those of the author(s) and should not contrued as an official Department of the Army position, policy or decision, unless so...Control Kit 3 8/14/2012 9 Statement of Problem Studied • We address the problem of maneuver-induced rollovers of ground vehicles in theatre. A bolt
Kit W-sh Mutation Prevents Cancellous Bone Loss during Calcium Deprivation.
Lotinun, Sutada; Suwanwela, Jaijam; Poolthong, Suchit; Baron, Roland
2018-01-01
Calcium is essential for normal bone growth and development. Inadequate calcium intake increases the risk of osteoporosis and fractures. Kit ligand/c-Kit signaling plays an important role in regulating bone homeostasis. Mice with c-Kit mutations are osteopenic. The present study aimed to investigate whether impairment of or reduction in c-Kit signaling affects bone turnover during calcium deprivation. Three-week-old male WBB6F1/J-Kit W /Kit W-v /J (W/W v ) mice with c-Kit point mutation, Kit W-sh /HNihrJaeBsmJ (W sh /W sh ) mice with an inversion mutation in the regulatory elements upstream of the c-Kit promoter region, and their wild-type controls (WT) were fed either a normal (0.6% calcium) or a low calcium diet (0.02% calcium) for 3 weeks. μCT analysis indicated that both mutants fed normal calcium diet had significantly decreased cortical thickness and cancellous bone volume compared to WT. The low calcium diet resulted in a comparable reduction in cortical bone volume and cortical thickness in the W/W v and W sh /W sh mice, and their corresponding controls. As expected, the low calcium diet induced cancellous bone loss in the W/W v mice. In contrast, W sh /W sh cancellous bone did not respond to this diet. This c-Kit mutation prevented cancellous bone loss by antagonizing the low calcium diet-induced increase in osteoblast and osteoclast numbers in the W sh /W sh mice. Gene expression profiling showed that calcium deficiency increased Osx, Ocn, Alp, type I collagen, c-Fms, M-CSF, and RANKL/OPG mRNA expression in controls; however, the W sh mutation suppressed these effects. Our findings indicate that although calcium restriction increased bone turnover, leading to osteopenia, the decreased c-Kit expression levels in the W sh /W sh mice prevented the low calcium diet-induced increase in cancellous bone turnover and bone loss but not the cortical bone loss.
Method and platform standardization in MRM-based quantitative plasma proteomics.
Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H
2013-12-16
There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.
Loss of c-Kit function impairs arteriogenesis in a mouse model of hindlimb ischemia.
Hernandez, Diana R; Artiles, Adriana; Duque, Juan C; Martinez, Laisel; Pinto, Mariana T; Webster, Keith A; Velazquez, Omaida C; Vazquez-Padron, Roberto I; Lassance-Soares, Roberta M
2018-04-01
Arteriogenesis is a process whereby collateral vessels remodel usually in response to increased blood flow and/or wall stress. Remodeling of collaterals can function as a natural bypass to alleviate ischemia during arterial occlusion. Here we used a genetic approach to investigate possible roles of tyrosine receptor c-Kit in arteriogenesis. Mutant mice with loss of c-Kit function (Kit W/W-v ), and controls were subjected to hindlimb ischemia. Blood flow recovery was evaluated pre-, post-, and weekly after ischemia. Foot ischemic damage and function were assessed between days 1 to 14 post-ischemia while collaterals remodeling were measured 28 days post-ischemia. Both groups of mice also were subjected to wild type bone marrow cells transplantation 3 weeks before hindlimb ischemia to evaluate possible contributions of defective bone marrow c-Kit expression on vascular recovery. Kit W/W-v mice displayed impaired blood flow recovery, greater ischemic damage and foot dysfunction after ischemia compared to controls. Kit W/W-v mice also demonstrated impaired collateral remodeling consistent with flow recovery findings. Because arteriogenesis is a biological process that involves bone marrow-derived cells, we investigated which source of c-Kit signaling (bone marrow or vascular) plays a major role in arteriogenesis. Kit W/W-v mice transplanted with bone marrow wild type cells exhibited similar phenotype of impaired blood flow recovery, greater tissue ischemic damage and foot dysfunction as nontransplanted Kit W/W-v mice. This study provides evidence that c-Kit signaling is required during arteriogenesis. Also, it strongly suggests a vascular role for c-Kit signaling because rescue of systemic c-Kit activity by bone marrow transplantation did not augment the functional recovery of Kit W/W-v mouse hindlimbs. Copyright © 2017 Elsevier Inc. All rights reserved.
In the Zone--Bringing Science to the Olympic Games for Students in 2012
ERIC Educational Resources Information Center
Holmes, Leah; Atkinson, Melissa; Schofield, Jonathan
2012-01-01
The Wellcome Trust is running a national engagement and education initiative inspired by the London 2012 Olympic and Paralympic Games. "In the Zone" involves sending practical science kits to every UK school and college. Here, we discuss the development of the school activities and how the feedback from pilot schools helped to shape the…
Figueira, Marília I; Cardoso, Henrique J; Correia, Sara; Maia, Cláudio J; Socorro, Sílvia
2017-10-01
The tyrosine kinase receptor c-KIT and its ligand, the stem cell factor (SCF) are expressed in several tissues of male and female reproductive tract, playing an important role in the regulation of basic biological processes. The activation of c-KIT by SCF controls, cell survival and death, cell differentiation and migration. Also, the SCF/c-KIT system has been implicated in carcinogenesis of reproductive tissues due to its altered expression pattern or overactivation in consequence of gain-of-functions mutations. Over the years, it has also been shown that hormones, the primary regulators of reproductive function and causative agents in the case of hormone-dependent cancers, are also able to control the SCF/c-KIT tissue levels. Therefore, it is liable to suppose that disturbed SCF/c-KIT expression driven by (de)regulated hormone actions can be a relevant step towards carcinogenesis. The present review describes the SCF and c-KIT expression in cancers of reproductive tissues, discussing the implications of the hormonal regulation of the SCF/c-KIT system in cancer development. Understanding the relationship between hormonal imbalance and the SCF/c-KIT expression and activity would be relevant in the context of novel therapeutic approaches in reproductive cancers. Copyright © 2017 Elsevier B.V. All rights reserved.
Telescience Resource Kit (TReK)
NASA Technical Reports Server (NTRS)
Lippincott, Jeff
2015-01-01
Telescience Resource Kit (TReK) is one of the Huntsville Operations Support Center (HOSC) remote operations solutions. It can be used to monitor and control International Space Station (ISS) payloads from anywhere in the world. It is comprised of a suite of software applications and libraries that provide generic data system capabilities and access to HOSC services. The TReK Software has been operational since 2000. A new cross-platform version of TReK is under development. The new software is being released in phases during the 2014-2016 timeframe. The TReK Release 3.x series of software is the original TReK software that has been operational since 2000. This software runs on Windows. It contains capabilities to support traditional telemetry and commanding using CCSDS (Consultative Committee for Space Data Systems) packets. The TReK Release 4.x series of software is the new cross platform software. It runs on Windows and Linux. The new TReK software will support communication using standard IP protocols and traditional telemetry and commanding. All the software listed above is compatible and can be installed and run together on Windows. The new TReK software contains a suite of software that can be used by payload developers on the ground and onboard (TReK Toolkit). TReK Toolkit is a suite of lightweight libraries and utility applications for use onboard and on the ground. TReK Desktop is the full suite of TReK software -most useful on the ground. When TReK Desktop is released, the TReK installation program will provide the option to choose just the TReK Toolkit portion of the software or the full TReK Desktop suite. The ISS program is providing the TReK Toolkit software as a generic flight software capability offered as a standard service to payloads. TReK Software Verification was conducted during the April/May 2015 timeframe. Payload teams using the TReK software onboard can reference the TReK software verification. TReK will be demonstrated on-orbit running on an ISS provided T61p laptop. Target Timeframe: September 2015 -2016. The on-orbit demonstration will collect benchmark metrics, and will be used in the future to provide live demonstrations during ISS Payload Conferences. Benchmark metrics and demonstrations will address the protocols described in SSP 52050-0047 Ku Forward section 3.3.7. (Associated term: CCSDS File Delivery Protocol (CFDP)).
78 FR 23688 - Airworthiness Directives; Bell Helicopter Textron Canada Inc. Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... would require replacing certain part-numbered engine auto-relight kit control boxes. This proposed AD is... range requirements, which could cause the control box to malfunction, disabling the engine auto-relight... helicopters with an engine auto-relight kit control box assembly (control box assembly) part number 206-375...
Disposable collection kit for rapid and reliable collection of saliva.
Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek
2015-01-01
To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R(2) > 0.96). The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. © 2015 Wiley Periodicals, Inc.
2013-01-01
Background Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists’ capacity to use these immunoassays to evaluate human clinical trials. Results The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose–response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Conclusions Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license. PMID:23631706
Eckels, Josh; Nathe, Cory; Nelson, Elizabeth K; Shoemaker, Sara G; Nostrand, Elizabeth Van; Yates, Nicole L; Ashley, Vicki C; Harris, Linda J; Bollenbeck, Mark; Fong, Youyi; Tomaras, Georgia D; Piehler, Britt
2013-04-30
Immunoassays that employ multiplexed bead arrays produce high information content per sample. Such assays are now frequently used to evaluate humoral responses in clinical trials. Integrated software is needed for the analysis, quality control, and secure sharing of the high volume of data produced by such multiplexed assays. Software that facilitates data exchange and provides flexibility to perform customized analyses (including multiple curve fits and visualizations of assay performance over time) could increase scientists' capacity to use these immunoassays to evaluate human clinical trials. The HIV Vaccine Trials Network and the Statistical Center for HIV/AIDS Research and Prevention collaborated with LabKey Software to enhance the open source LabKey Server platform to facilitate workflows for multiplexed bead assays. This system now supports the management, analysis, quality control, and secure sharing of data from multiplexed immunoassays that leverage Luminex xMAP® technology. These assays may be custom or kit-based. Newly added features enable labs to: (i) import run data from spreadsheets output by Bio-Plex Manager™ software; (ii) customize data processing, curve fits, and algorithms through scripts written in common languages, such as R; (iii) select script-defined calculation options through a graphical user interface; (iv) collect custom metadata for each titration, analyte, run and batch of runs; (v) calculate dose-response curves for titrations; (vi) interpolate unknown concentrations from curves for titrated standards; (vii) flag run data for exclusion from analysis; (viii) track quality control metrics across runs using Levey-Jennings plots; and (ix) automatically flag outliers based on expected values. Existing system features allow researchers to analyze, integrate, visualize, export and securely share their data, as well as to construct custom user interfaces and workflows. Unlike other tools tailored for Luminex immunoassays, LabKey Server allows labs to customize their Luminex analyses using scripting while still presenting users with a single, graphical interface for processing and analyzing data. The LabKey Server system also stands out among Luminex tools for enabling smooth, secure transfer of data, quality control information, and analyses between collaborators. LabKey Server and its Luminex features are freely available as open source software at http://www.labkey.com under the Apache 2.0 license.
Development and evaluation of the RT-PCR kit for the rabies virus diagnosis.
Dedkov, Vladimir G; Deviatkin, A A; Poleschuk, E M; Safonova, M V; Markelov, M L; Shipulin, G A
To improve the diagnosis, surveillance, and control for the rabies virus, a kit for hybridization-triggered fluorescence detection of rabies virus DNA by the RT-PCR technique was developed and evaluated. The analytical sensitivity of the kit was 4*10 GE per ml. High specificity of the kit was shown using representative sampling of viral, bacterial, and human nucleic acids.
Elevated expression of the proto-oncogene c-kit in patients with mastocytosis.
Nagata, H; Worobec, A S; Semere, T; Metcalfe, D D
1998-02-01
The stem cell factor (SCF)c-kit receptor interaction plays a critical role in the development and survival of mast cells. Several studies have also associated c-kit receptor mutations with the human diseases, mastocytosis and piebaldism. Overexpression of c-kit has been reported to be associated with myeloproliferative disorders and myelodysplastic syndromes. Using peripheral blood mononuclear cells (PBMCs) from 11 patients with indolent mastocytosis (category I), mastocytosis with an associated hematologic disorder (category II), or aggressive mastocytosis (category III); a patient with CMML unassociated with mastocytosis, and PBMCs from 13 normal subjects, we examined the level of expression of c-kit mRNA along with other c-kit isoforms to determine if overexpression of the c-kit receptor was associated with mastocytosis. Using quantitative competitive PCR, c-kit mRNA levels on average were found to be statistically elevated in the five patients with mastocytosis with an associated hematologic disorder and in the patient with aggressive mastocytosis as compared with controls, but not elevated in patients with indolent mastocytosis. The relative mRNA expression for the two c-kit isoforms was not significantly different in the mastocytosis patients compared with controls. This demonstration of the overexpression of c-kit mRNA in mastocytosis, and particularly those patients with clinical evidence of myelodysplastic syndrome, adds evidence to support the conclusion that mastocytosis, at least in some patients, is a feature of myelodysplasia; and suggests that determination of c-kit mRNA expression in PBMCs may provide an additional approach to assessing prognosis.
Guthoff, Rudolf F; Wienss, Holger; Hahnel, Christian; Wree, Andreas
2005-07-01
Evaluation of a new method to visualize distribution and morphology of human corneal nerves (Adelta- and C-fibers) by means of fluorescence staining, confocal laser scanning microscopy, and 3-dimensional (3D) reconstruction. Trephinates of corneas with a diagnosis of Fuchs corneal dystrophy were sliced into layers of 200 microm thickness using a Draeger microkeratome (Storz, Germany). The anterior lamella was stained with the Life/Dead-Kit (Molecular Probes Inc.), examined by the confocal laser scanning microscope "Odyssey XL," step size between 0.5 and 1 microm, and optical sections were digitally 3D-reconstructed. Immediate staining of explanted corneas by the Life/Dead-Kit gave a complete picture of the nerves in the central human cornea. Thin nerves running parallel to the Bowman layer in the subepithelial plexus perforate the Bowman layer orthogonally through tube-like structures. Passing the Bowman layer, Adelta- and C-fibers can be clearly distinguished by fiber diameter, and, while running in the basal epithelial plexus, by their spatial arrangement. Adelta-fibers run straight and parallel to the Bowman layer underneath the basal cell layer. C-fibers, after a short run parallel to the Bowman layer, send off multiple branches penetrating epithelial cell layers orthogonally, ending blindly in invaginations of the superficial cells. In contrast to C-fibers, Adelta-fibers show characteristic bulbous formations when kinking into the basal epithelial plexus. Ex-vivo fluorescence staining of the cornea and 3D reconstructions of confocal scans provide a fast and easily reproducible tool to visualize nerves of the anterior living cornea at high resolution. This may help to clarify gross variations of nerve fiber patterns under various clinical and experimental conditions.
Disposable Collection Kit for Rapid and Reliable Collection of Saliva
Yamaguchi, Masaki; Tezuka, Yuki; Takeda, Kazunori; Shetty, Vivek
2015-01-01
Objectives To describe and evaluate disposable saliva collection kit for rapid, reliable, and reproducible collection of saliva samples. Methods The saliva collection kit comprised of a saliva absorbent swab and an extractor unit was used to retrieve whole saliva samples from 10 subjects. The accuracy and precision of the extracted volumes (3, 10, and 30 μl) were compared to similar volumes drawn from control samples obtained by passive drool. Additionally, the impact of kit collection method on subsequent immunoassay results was verified by assessing salivary cortisol levels in the samples and comparing them to controls. Results The recovered volumes for the whole saliva samples were 3.85 ± 0.28, 10.79 ± 0.95, and 31.18 ± 1.72 μl, respectively (CV = 8.76%) and 2.91 ± 0.19, 9.75 ± 0.43, and 29.64 ± 0.91 μl, respectively, (CV = 6.36%) for the controls. There was a close correspondence between the salivary cortisol levels from the saliva samples obtained by the collection kit and the controls (R2 > 0.96). Conclusions The disposable saliva collection kit allows accurate and repeatable collection of fixed amounts of whole saliva and does not interfere with subsequent measurements of salivary cortisol. The simple collection process, lack of elaborate specimen recovery steps, and the short turnaround time (<3 min) should render the kit attractive to test subjects and researchers alike. Am. J. Hum. Biol. 27:720–723, 2015. © 2015 The Authors American Journal of Human Biology Published by Wiley Periodicals, Inc. PMID:25754371
NASA Astrophysics Data System (ADS)
2009-03-01
WE RECOMMEND The Age of Wonder This book tells the stories of inspiring 19th-century scientists Antimatter A fast read that gives an intriguing tour of the antimatter world Science Fiction-Science Fact A video from a set of resources about the facts in science fiction WORTH A LOOK Portoscope Lightweight ×30 microscope that is easy on the purse Four Laws that Drive the Universe In just 124 pages Peter Atkins explains thermodynamics Coffee Saver Starter Kit A tool that can demonstrate the effect of reduced air pressure Graphite Levitation Kit Compact set that demonstrates diamagnetic behaviour Critical Reading A study guide on how to read scientific papers HANDLE WITH CARE Around the World in 80 Images Navigate through images from Envistat, country by country WEB WATCH This month's issue features real-time simulation program Krucible 2.0, which enables learners to run virtual experiments
Medics as a channel for worksite health promotion in remote global locations.
Bisits Bullen, Piroska A
2012-01-01
In the energy and mining sectors, it is common for employees to work in geographically remote locations, often with a medic for emergency response. This study evaluated an intervention to increase the number of medics conducting health promotion in remote worksites. Interviews were conducted to gather data for informing intervention and survey development. The intervention was evaluated in a quasiexperimental posttest-only comparison group design using survey data collected at baseline and again after 12 months. The intervention was implemented in remote worksites (N = 201). There were 96 worksites in the intervention condition and 105 sites in the control condition. The target population was medics, including nurses, doctors, and paramedics, operating in remote worksites in 44 countries. The intervention was a series of campaign tool kits. The tool kits were adapted to the remote environment and could be customized for culture, language, and education level. The survey assessed frequency of health promotion activities, satisfaction with the intervention, and barriers to implementation. Survey data were analyzed using descriptive statistics and χ(2) tests. Interview results were coded to identify themes. Most medics (88%) in the intervention group reported running "tool box talks" (short education sessions) on at least a monthly basis, compared with 78% in the comparison group (p = .056). The trend was similar for displaying posters (71% vs. 55%; p = .021) and advocating for policy changes (84% vs. 71%; p = .027). Medic satisfaction was high. Difficulty distributing tool kits was the main barrier to implementation. When provided with appropriate tools, medics may be an ideal channel for health promotion in remote worksites.
Bastani, Roshan; Danao, Leda L.; Antonio, Cynthia; Garcia, Gabriel M.; Crespi, Catherine M.
2010-01-01
Objectives. We conducted 1 of the first community-based trials to develop a multicomponent intervention that would increase colorectal cancer screening among an Asian American population. Methods. Filipino Americans (n = 548) nonadherent to colorectal cancer (CRC) screening guidelines were randomized into an intervention group that received an education session on CRC screening and free fecal occult blood test (FOBT) kits; a second intervention group that received an education session but no free FOBT kits; and a control group that received an education session on the health benefits of physical activity. Results. Self-reported CRC screening rates during the 6-month follow-up period were 30%, 25%, and 9% for participants assigned to intervention with FOBT kit, intervention without the kit, and control group, respectively. Participants in either of the 2 intervention groups were significantly more likely to report screening at follow-up than were participants in the control group. Conclusions. A multicomponent intervention that includes an educational group session in a community setting can significantly increase CRC screening among Filipino Americans, even when no free FOBT kits are distributed. PMID:20864724
Service Test of the Airfield Specialized Trailer System
1966-10-31
universal trailer is a lightweight, air-transportable, four- wheel trailer. It is capable of transferring loads to compatible main- tenance and storage...transverse beams). The suspension sys- tem is a specially designed, three-point system which protects loads from excessive wheel displacement when...lightweight steel and can accommodate hoist and lift facilities. Sockets are provided to permit attachment of several accessory kits (running gear caster
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
An OpenStudio Measure is a script that can manipulate an OpenStudio model and associated data to apply energy conservation measures (ECMs), run supplemental simulations, or visualize simulation results. The OpenStudio software development kit (SDK) and accessibility of the Ruby scripting language makes measure authorship accessible to both software developers and energy modelers. This paper discusses the life cycle of an OpenStudio Measure from development, testing, and distribution, to application.
Improved Quantification of Plasma Catecholamines by the Radioenzymic Kit Method.
1982-11-01
Diagnostics under the tradename CAT -A-KIT. In the Up- john procedure (2) each "unknown" and control specimen is analyzed with and without addition of an...the purpose of this report includes the follow- ing: (a) to recount difficulties we initially encountered in the prescribed use of CAT -A-KITs for...with each CAT -A-KIT, (c) to describe our departure from the prescribed procedure, (d) to validate that departure through intermethod/ interlaboratory
Arsenic exposure in drinking water: an unrecognized health threat in Peru.
George, Christine Marie; Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H
2014-08-01
To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick(™) (EQ) kit for measuring water arsenic concentrations in the field. Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1-93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance.
Effectiveness of a multimedia outreach kit for families of wounded veterans.
Walker, David Ian; Cardin, Jean-François; Chawla, Neelu; Topp, David; Burton, Thomaseo; Macdermid Wadsworth, Shelley
2014-04-01
Young children in military families with a member who has a life changing injury can experience emotional difficulties and behavior changes. This study evaluated a Sesame Workshop multimedia kit called: Talk, Listen, Connect: Changes (TLC-II(C); 2008). The kit, which included video and print materials, aimed to help caregivers (i.e., at-home partner, at-home relative or family member of a current or discharged military member) assist young children as they adjusted to their parent's injury. We expected that the materials would be used and their quality evaluated. We hypothesized that use of the materials would produce improvements in caregiver and child outcomes as well as reductions in perceptions of disruption in the home. We also predicted that kit-use would have a positive impact on the family. One-hundred and fifty three families with children aged 2-8 years were randomly assigned to receive the kit being evaluated (TLC-II(C)) or a control kit (Healthy Habits for Life (HHL)), also developed by Sesame Workshop. Group outcomes were compared four weeks following receipt of the kits using multivariate analysis of variance. All materials were well used and highly rated. All caregivers reported less social isolation, less child aggression, and significantly less disruptive home environments after kit use. Test group caregivers reported significantly greater reductions in depressive symptoms and significant increases in children's social competence over time in comparison to the control group. These results signal important improvements among families as a consequence of using either test or control materials. As a preventative intervention designed for families with an injured member, TLC-II(C) was particularly effective at improving coping. Copyright © 2014 Elsevier Inc. All rights reserved.
Omid Early Intervention Resource Kit for Children with Autism Spectrum Disorders and Their Families
ERIC Educational Resources Information Center
Samadi, Sayyed Ali; Mahmoodizadeh, Ameneh
2014-01-01
Omid early intervention resource kit containing information booklets on autism spectrum disorders (ASD) and related issues, five packs of tangible selected playthings and communication facilitating aids was developed and evaluated with 65 Iranian parents. Beside a pretest before the resource kit deliverance, parents in the control group took part…
Liu, Zhen; Li, Shuo; Liu, Lingling; Guo, Zhikun; Wang, Pengfei
2016-09-01
The present study aimed to investigate the dynamic expression of the c-kit and nanog genes in rats with left ventricular remodelling induced by adriamycin (ADR), and explore its internal association and mechanism of action. Sprague-Dawley male rats were randomly divided into a normal control group and a heart failure model group. Heart failure was induced by a single intraperitoneal injection of ADR (4 mg/kg) weekly for six weeks. The normal control group was given the same amount of saline. At the eighth week, rat cardiac function was examined to demonstrate the formation of heart failure. The rat hearts were harvested frozen and sectioned, and the expression levels of the nanog and c-kit genes in the myocardial tissue samples were detected using immunohistochemistry, immunofluorescence and reverse transcription-polymerase chain reaction (RT-PCR). Hematoxylin and eosin staining demonstrated various pathological changes in the myocardial cells in the heart failure model group, whereas myocardial infarction was not observed in the normal control group. Immunohistochemistry and immunofluorescence demonstrated that nanog-positive cells were predominantly expressed in the vascular endothelium, with a few myocardial cells and stem cells in normal myocardium. The expression levels of c-kit and nanog in the myocardium of the rats with heart failure decreased significantly. c-kit-positive cells clustered together in the epicardium and its vicinity, and c-kit expression significantly decreased in the myocardium of rats with heart failure, as compared with normal rats. In both groups, some cells co-expressed both the c-kit and nanog genes. The RT-PCR results demonstrated that the expression levels of the two genes in the heart failure model group were significantly lower compared with those in the normal control group (P<0.05). In conclusion, the c-kit- and nanog-positive stem cells decreased in the myocardium of the rats with left ventricular remodelling induced by ADR. Their abnormal expression was significantly correlated with left ventricular remodelling, thereby indicating an internal association (influences of two indexes in the experimental group and control group) between them.
Singh, Satyendra; Klarmann, Kimberly D.; Coppola, Vincenzo; Keller, Jonathan R.; Tessarollo, Lino
2016-01-01
c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies. PMID:27835883
Puverel, Sandrine; Kiris, Erkan; Singh, Satyendra; Klarmann, Kimberly D; Coppola, Vincenzo; Keller, Jonathan R; Tessarollo, Lino
2016-12-20
c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies.
Jiang, Feng; Hu, Wei; Zhang, Bicheng; Xu, Jing; Shui, Yongjie; Zhou, Xiaofeng; Ren, Xiaoqiu; Chen, Xiaozhong; Shen, Li; Wei, Qichun
2016-10-01
In the era of intensity-modulated radiotherapy, distant metastasis is currently the main cause of treatment failure for nasopharyngeal carcinoma (NPC). Additional therapeutic strategies are required to control the metastasis and improve survival. One strategy is targeted therapy, for example against c-Kit. In the current study, the frequency of c-Kit expression was determined immunohistochemically in 106 NPC patients. c-Kit expression changes during the course of radiation therapy were detected in 41 cases via weekly biopsy. Twelve cases (11.3%) had c-Kit expression scores of 3 + and 16 (15.1%) had scores of 2 + . Thus, c-Kit overexpression (2 + or 3 + ) was observed in 28 (26.4%) patients. There were 35 (33.0%) and 43 (40.6%) patients with c-Kit expression scores of 1 + and 0, respectively. Furthermore, a trend of decreased c-Kit expression was observed after commencing radiotherapy according to the 41 NPC patients who were biopsied weekly. Therefore, c-Kit overexpression was identified to be common in NPC, and evaluating c-Kit as a therapeutic target for metastatic NPC via c-Kit overexpression subsequent to first line treatment may be of interest. To the best of our knowledge, the present study is the first to demonstrate a trend of decreased c-Kit expression during the course of radiotherapy.
Using Control Heuristics as a Means to Explore the Educational Potential of Robotics Kits
ERIC Educational Resources Information Center
Gaudiello, Ilaria; Zibetti, Elisabetta
2013-01-01
The educational potential of robotics kits as a form of control technology will remain undervalued until meaningful observation parameters are identified to enable a better understanding of children?s control strategies. For this reason, this paper aims primarily to identify and classify the heuristics spontaneously applied by 6-10 year old…
Gebreyohannes, Yemarshet K; Schöffski, Patrick; Van Looy, Thomas; Wellens, Jasmien; Vreys, Lise; Cornillie, Jasmien; Vanleeuw, Ulla; Aftab, Dana T; Debiec-Rychter, Maria; Sciot, Raf; Wozniak, Agnieszka
2016-12-01
In the majority of gastrointestinal stromal tumors (GIST), oncogenic signaling is driven by KIT mutations. Advanced GIST is treated with tyrosine kinase inhibitors (TKI) such as imatinib. Acquired resistance to TKI is mainly caused by secondary KIT mutations, but can also be attributed to a switch of KIT dependency to another receptor tyrosine kinase (RTK). We tested the efficacy of cabozantinib, a novel TKI targeting KIT, MET, AXL, and vascular endothelial growth factor receptors (VEGFR), in patient-derived xenograft (PDX) models of GIST, carrying different KIT mutations. NMRI nu/nu mice (n = 52) were bilaterally transplanted with human GIST: UZLX-GIST4 (KIT exon 11 mutation, imatinib sensitive), UZLX-GIST2 (KIT exon 9, imatinib dose-dependent resistance), or UZLX-GIST9 (KIT exon 11 and 17 mutations, imatinib resistant). Mice were grouped as control (untreated), imatinib (50 mg/kg/bid), and cabozantinib (30 mg/kg/qd) and treated orally for 15 days. Cabozantinib resulted in significant tumor regression in UZLX-GIST4 and -GIST2 and delayed tumor growth in -GIST9. In all three models, cabozantinib inhibited the proliferative activity, which was completely absent in UZLX-GIST4 and significantly reduced in -GIST2 and -GIST9. Increased apoptotic activity was observed only in UZLX-GIST4. Cabozantinib inhibited the KIT signaling pathway in UZLX-GIST4 and -GIST2. In addition, compared with both control and imatinib, cabozantinib significantly reduced microvessel density in all models. In conclusion, cabozantinib showed antitumor activity in GIST PDX models through inhibition of tumor growth, proliferation, and angiogenesis, in both imatinib-sensitive and imatinib-resistant models. Mol Cancer Ther; 15(12); 2845-52. ©2016 AACR. ©2016 American Association for Cancer Research.
Mayado, A; Teodosio, C; Dasilva-Freire, N; Jara-Acevedo, M; Garcia-Montero, A C; Álvarez-Twose, I; Sánchez-Muñoz, L; Matito, A; Caldas, C; Muñoz-González, J I; Henriques, A; Sánchez-Gallego, J I; Escribano, L; Orfao, A
2018-01-13
Recent studies show that most systemic mastocytosis (SM) patients, including indolent SM (ISM) with (ISMs+) and without skin lesions (ISMs-), carry the KIT D816V mutation in PB leukocytes. We investigated the potential association between the degree of involvement of BM hematopoiesis by the KIT D816V mutation and the distribution of different maturation-associated compartments of bone marrow (BM) and peripheral blood (PB) CD34 + hematopoietic precursors (HPC) in ISM and identified the specific PB cell compartments that carry this mutation. The distribution of different maturation-associated subsets of BM and PB CD34 + HPC from 64 newly diagnosed (KIT-mutated) ISM patients and 14 healthy controls was analyzed by flow cytometry. In 18 patients, distinct FACS-purified PB cell compartments were also investigated for the KIT mutation. ISM patients showed higher percentages of both BM and PB MC-committed CD34 + HPC vs controls, particularly among ISM cases with MC-restricted KIT mutation (ISM MC ); this was associated with progressive blockade of maturation of CD34 + HPC to the neutrophil lineage from ISM MC to multilineage KIT-mutated cases (ISM ML ). Regarding the frequency of KIT-mutated cases and cell populations in PB, variable patterns were observed, the percentage of KIT-mutated PB CD34 + HPC, eosinophils, neutrophils, monocytes and T cells increasing from ISMs- MC and ISMs+ MC to ISM ML patients. The presence of the KIT D816V mutation in PB of ISM patients is associated with (early) involvement of circulating CD34 + HPC and multiple myeloid cell subpopulations, KIT-mutated PB CD34 + HPC potentially contributing to early dissemination of the disease. © 2018 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.
Development of a platform-independent receiver control system for SISIFOS
NASA Astrophysics Data System (ADS)
Lemke, Roland; Olberg, Michael
1998-05-01
Up to now receiver control software was a time consuming development usually written by receiver engineers who had mainly the hardware in mind. We are presenting a low-cost and very flexible system which uses a minimal interface to the real hardware, and which makes it easy to adapt to new receivers. Our system uses Tcl/Tk as a graphical user interface (GUI), SpecTcl as a GUI builder, Pgplot as plotting software, a simple query language (SQL) database for information storage and retrieval, Ethernet socket to socket communication and SCPI as a command control language. The complete system is in principal platform independent but for cost saving reasons we are using it actually on a PC486 running Linux 2.0.30, which is a copylefted Unix. The only hardware dependent part are the digital input/output boards, analog to digital and digital to analog convertors. In the case of the Linux PC we are using a device driver development kit to integrate the boards fully into the kernel of the operating system, which indeed makes them look like an ordinary device. The advantage of this system is firstly the low price and secondly the clear separation between the different software components which are available for many operating systems. If it is not possible, due to CPU performance limitations, to run all the software in a single machine,the SQL-database or the graphical user interface could be installed on separate computers.
The Automated Instrumentation and Monitoring System (AIMS) reference manual
NASA Technical Reports Server (NTRS)
Yan, Jerry; Hontalas, Philip; Listgarten, Sherry
1993-01-01
Whether a researcher is designing the 'next parallel programming paradigm,' another 'scalable multiprocessor' or investigating resource allocation algorithms for multiprocessors, a facility that enables parallel program execution to be captured and displayed is invaluable. Careful analysis of execution traces can help computer designers and software architects to uncover system behavior and to take advantage of specific application characteristics and hardware features. A software tool kit that facilitates performance evaluation of parallel applications on multiprocessors is described. The Automated Instrumentation and Monitoring System (AIMS) has four major software components: a source code instrumentor which automatically inserts active event recorders into the program's source code before compilation; a run time performance-monitoring library, which collects performance data; a trace file animation and analysis tool kit which reconstructs program execution from the trace file; and a trace post-processor which compensate for data collection overhead. Besides being used as prototype for developing new techniques for instrumenting, monitoring, and visualizing parallel program execution, AIMS is also being incorporated into the run-time environments of various hardware test beds to evaluate their impact on user productivity. Currently, AIMS instrumentors accept FORTRAN and C parallel programs written for Intel's NX operating system on the iPSC family of multi computers. A run-time performance-monitoring library for the iPSC/860 is included in this release. We plan to release monitors for other platforms (such as PVM and TMC's CM-5) in the near future. Performance data collected can be graphically displayed on workstations (e.g. Sun Sparc and SGI) supporting X-Windows (in particular, Xl IR5, Motif 1.1.3).
Combined KIT and FGFR2b Signaling Regulates Epithelial Progenitor Expansion during Organogenesis
Lombaert, Isabelle M.A.; Abrams, Shaun R.; Li, Li; Eswarakumar, Veraragavan P.; Sethi, Aditya J.; Witt, Robert L.; Hoffman, Matthew P.
2013-01-01
Summary Organ formation and regeneration require epithelial progenitor expansion to engineer, maintain, and repair the branched tissue architecture. Identifying the mechanisms that control progenitor expansion will inform therapeutic organ (re)generation. Here, we discover that combined KIT and fibroblast growth factor receptor 2b (FGFR2b) signaling specifically increases distal progenitor expansion during salivary gland organogenesis. FGFR2b signaling upregulates the epithelial KIT pathway so that combined KIT/FGFR2b signaling, via separate AKT and mitogen-activated protein kinase (MAPK) pathways, amplifies FGFR2b-dependent transcription. Combined KIT/FGFR2b signaling selectively expands the number of KIT+K14+SOX10+ distal progenitors, and a genetic loss of KIT signaling depletes the distal progenitors but also unexpectedly depletes the K5+ proximal progenitors. This occurs because the distal progenitors produce neurotrophic factors that support gland innervation, which maintains the proximal progenitors. Furthermore, a rare population of KIT+FGFR2b+ cells is present in adult glands, in which KIT signaling also regulates epithelial-neuronal communication during homeostasis. Our findings provide a framework to direct regeneration of branched epithelial organs. PMID:24371813
40 CFR 1045.655 - What special provisions apply for installing and removing altitude kits?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply for installing and removing altitude kits? 1045.655 Section 1045.655 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
40 CFR 1045.655 - What special provisions apply for installing and removing altitude kits?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What special provisions apply for installing and removing altitude kits? 1045.655 Section 1045.655 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
40 CFR 1045.655 - What special provisions apply for installing and removing altitude kits?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What special provisions apply for installing and removing altitude kits? 1045.655 Section 1045.655 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
40 CFR 1045.655 - What special provisions apply for installing and removing altitude kits?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What special provisions apply for installing and removing altitude kits? 1045.655 Section 1045.655 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
40 CFR 1045.655 - What special provisions apply for installing and removing altitude kits?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What special provisions apply for installing and removing altitude kits? 1045.655 Section 1045.655 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
21 CFR 866.2480 - Quality control kit for culture media.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Quality control kit for culture media. 866.2480 Section 866.2480 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2480 Quality...
Chauvot de Beauchêne, Isaure; Allain, Ariane; Panel, Nicolas; Laine, Elodie; Trouvé, Alain; Dubreuil, Patrice; Tchertanov, Luba
2014-01-01
Receptor tyrosine kinase KIT controls many signal transduction pathways and represents a typical allosterically regulated protein. The mutation-induced deregulation of KIT activity impairs cellular physiological functions and causes serious human diseases. The impact of hotspots mutations (D816H/Y/N/V and V560G/D) localized in crucial regulatory segments, the juxtamembrane region (JMR) and the activation (A-) loop, on KIT internal dynamics was systematically studied by molecular dynamics simulations. The mutational outcomes predicted in silico were correlated with in vitro and in vivo activation rates and drug sensitivities of KIT mutants. The allosteric regulation of KIT in the native and mutated forms is described in terms of communication between the two remote segments, JMR and A-loop. A strong correlation between the communication profile and the structural and dynamical features of KIT in the native and mutated forms was established. Our results provide new insight on the determinants of receptor KIT constitutive activation by mutations and resistance of KIT mutants to inhibitors. Depiction of an intra-molecular component of the communication network constitutes a first step towards an integrated description of vast communication pathways established by KIT in physiopathological contexts. PMID:25079768
Ha, Tam Cam; Yong, Sook Kwin; Yeoh, Kheng-Wei; Kamberakis, Kay; Yeo, Richard Ming Chert; Koh, Gerald Choon-Huat
2014-11-01
The purpose of the study was to investigate whether fecal occult blood test (FOBT) home-delivery and individual education or combined with family education increases FOBT uptake rates in Singapore. This is a randomized controlled intervention study of Singaporean residents aged 50 years and above, conducted in May 2012 till May 2013. Eligible individuals in randomly selected households were screened, and one member was randomly selected and allocated to one of the four arms: Group A (individual and family education, FOBT kits provided), Group B (individual education only, FOBT kits provided), Group C (no education, FOBT kits provided) and Group D (no education or FOBT kits provided). Overall response rate was 74.7 %. The FOBT return rates for groups A, B, C and D were 24.5 % [CI 16.2-34.4 %], 25.3 % [CI 16.4-36.0 %], 10.7 % [CI 4.7-19.9 %] and 2.2 % [CI 0.3-7.7 %], respectively. Respondents who were provided education and home-delivered FOBT kits were 15 times more likely to return FOBT kits [Group A: OR 15.0 (3.4-66.2); Group B: OR 15.5 (3.5-68.8)] and those provided with home-delivered FOBT without education were five times more likely to return FOBT kits [Group C: OR 5.8 (1.2-28.3)] than those without education and FOBT kits (Group D). There was no significant difference in return of FOBT kits whether education was provided to subject with or without a family member. Home delivery of FOBT kits increased FOBT return rates and individual education combined with home-delivered FOBT increased FOBT return rates even further. However, additional combination with family education did not increase FOBT rates further.
Detection of KIT Genotype in Pigs by TaqMan MGB Real-Time Quantitative Polymerase Chain Reaction.
Li, Xiuxiu; Li, Xiaoning; Luo, Rongrong; Wang, Wenwen; Wang, Tao; Tang, Hui
2018-05-01
The dominant white phenotype in domestic pigs is caused by two mutations in the KIT gene: a 450 kb duplication containing the entire KIT gene together with flanking sequences and one splice mutation with a G:A substitution in intron 17. The purpose of this study was to establish a simple, rapid method to determine KIT genotype in pigs. First, to detect KIT copy number variation (CNV), primers for exon 2 of the KIT gene, along with a TaqMan minor groove binder (MGB) probe, were designed. The single-copy gene, estrogen receptor (ESR), was used as an internal control. A real-time fluorescence-based quantitative PCR (FQ-PCR) protocol was developed to accurately detect KIT CNVs. Second, to detect the splice mutation ratio of the G:A substitution in intron 17, a 175 bp region, including the target mutation, was amplified from genomic DNA. Based on the sequence of the resulting amplified fragment, an MGB probe set was designed to detect the ratio of splice mutation to normal using FQ-PCR. A series of parallel amplification curves with the same internal distances were obtained using gradually diluted DNA as templates. The CT values among dilutions were significantly different (p < 0.001) and the coefficients of variation from each dilution were low (from 0.13% to 0.26%). The amplification efficiencies for KIT and ESR were approximately equal, indicating ESR was an appropriate control gene. Furthermore, use of the MGB probe set resulted in detection of the target mutation at a high resolution and stability; standard curves illustrated that the amplification efficiencies of KIT1 (G) and KIT2 (A) were approximately equal (98.8% and 97.2%). In conclusion, a simple, rapid method, with high specificity and stability, for the detection of the KIT genotype in pigs was established using TaqMan MGB probe real-time quantitative PCR.
Ravignani, Andrea; Olivera, Vicente Matellán; Gingras, Bruno; Hofer, Riccardo; Hernández, Carlos Rodríguez; Sonnweber, Ruth-Sophie; Fitch, W. Tecumseh
2013-01-01
The possibility of achieving experimentally controlled, non-vocal acoustic production in non-human primates is a key step to enable the testing of a number of hypotheses on primate behavior and cognition. However, no device or solution is currently available, with the use of sensors in non-human animals being almost exclusively devoted to applications in food industry and animal surveillance. Specifically, no device exists which simultaneously allows: (i) spontaneous production of sound or music by non-human animals via object manipulation, (ii) systematical recording of data sensed from these movements, (iii) the possibility to alter the acoustic feedback properties of the object using remote control. We present two prototypes we developed for application with chimpanzees (Pan troglodytes) which, while fulfilling the aforementioned requirements, allow to arbitrarily associate sounds to physical object movements. The prototypes differ in sensing technology, costs, intended use and construction requirements. One prototype uses four piezoelectric elements embedded between layers of Plexiglas and foam. Strain data is sent to a computer running Python through an Arduino board. A second prototype consists in a modified Wii Remote contained in a gum toy. Acceleration data is sent via Bluetooth to a computer running Max/MSP. We successfully pilot tested the first device with a group of chimpanzees. We foresee using these devices for a range of cognitive experiments. PMID:23912427
Ravignani, Andrea; Matellán Olivera, Vicente; Gingras, Bruno; Hofer, Riccardo; Rodríguez Hernández, Carlos; Sonnweber, Ruth-Sophie; Fitch, W Tecumseh
2013-07-31
The possibility of achieving experimentally controlled, non-vocal acoustic production in non-human primates is a key step to enable the testing of a number of hypotheses on primate behavior and cognition. However, no device or solution is currently available, with the use of sensors in non-human animals being almost exclusively devoted to applications in food industry and animal surveillance. Specifically, no device exists which simultaneously allows: (i) spontaneous production of sound or music by non-human animals via object manipulation, (ii) systematical recording of data sensed from these movements, (iii) the possibility to alter the acoustic feedback properties of the object using remote control. We present two prototypes we developed for application with chimpanzees (Pan troglodytes) which, while fulfilling the aforementioned requirements, allow to arbitrarily associate sounds to physical object movements. The prototypes differ in sensing technology, costs, intended use and construction requirements. One prototype uses four piezoelectric elements embedded between layers of Plexiglas and foam. Strain data is sent to a computer running Python through an Arduino board. A second prototype consists in a modified Wii Remote contained in a gum toy. Acceleration data is sent via Bluetooth to a computer running Max/MSP. We successfully pilot tested the first device with a group of chimpanzees. We foresee using these devices for a range of cognitive experiments.
Evaluation of Commercially Available Chikungunya Virus Immunoglobulin M Detection Assays
Johnson, Barbara W.; Goodman, Christin H.; Holloway, Kimberly; de Salazar, P. Martinez; Valadere, Anne M.; Drebot, Michael A.
2016-01-01
Commercial chikungunya virus (CHIKV)–specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA had high performance at CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. PMID:26976887
2008-07-31
Lipofectamine-mediated transfection of pcDNA3/c-Kit. Chemosensitivity to the c-Kit modulating drugs, imatinib and alpha - fetoprotein -derived peptide (AFPep), was...Cancer Res. 10:3528-3534. 7. Bennett JA, Mesfin FB, Andersen TT, Gierthy JF, and Jacobson HI. (2002). A peptide derived from α- fetoprotein prevents
Yip, Cyril C Y; Sridhar, Siddharth; Cheng, Andrew K W; Fung, Ami M Y; Cheng, Vincent C C; Chan, Kwok-Hung; Yuen, Kwok-Yung
2017-08-01
HHV-6 reactivation in immunocompromised patients is common and may be associated with serious morbidity and mortality; therefore, early detection and initiation of therapy might be of benefit. Real-time PCR assays allow for early identification of HHV-6 reactivation to assist in providing a timely response. Thus, we compared the performance of an in-house developed HHV-6 quantitative PCR assay with a commercially available kit, the RealStar ® HHV-6 PCR Kit. The analytical sensitivity, analytical specificity, linearity, precision and accuracy of the in-house developed HHV-6 qPCR assay were evaluated. The diagnostic performance of the in-house HHV-6 qPCR assay was compared with the RealStar ® HHV-6 PCR Kit, using 72 clinical specimens and 17 proficiency testing samples. Linear regression analysis of the quantitative results showed a dynamic range from 2 to 10 log 10 copies/ml and a coefficient of determination (R 2 ) of 0.999 for the in-house assay. A dilution series demonstrated a limit of detection and a limit of quantification of 1.7 log 10 and 2 log 10 copies/ml, respectively. The precision of the assay was highly reproducible among runs with coefficients of variance (CV) ranging from 0.27% to 4.37%. A comparison of 27 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house HHV-6 qPCR assay and the RealStar ® HHV-6 PCR Kit (R 2 =0.926; P<0.0001), with an average bias of -0.24 log 10 copies/ml. The in-house developed HHV-6 qPCR method is a sensitive and reliable assay with lower cost for the detection and quantification of HHV-6 DNA when compared to the RealStar ® HHV-6 PCR Kit. Copyright © 2017 Elsevier B.V. All rights reserved.
Lock Acquisition and Sensitivity Analysis of Advanced LIGO Interferometers
NASA Astrophysics Data System (ADS)
Martynov, Denis
Laser interferometer gravitational wave observatory (LIGO) consists of two complex large-scale laser interferometers designed for direct detection of gravitational waves from distant astrophysical sources in the frequency range 10Hz - 5kHz. Direct detection of space-time ripples will support Einstein's general theory of relativity and provide invaluable information and new insight into physics of the Universe. The initial phase of LIGO started in 2002, and since then data was collected during the six science runs. Instrument sensitivity improved from run to run due to the effort of commissioning team. Initial LIGO has reached designed sensitivity during the last science run, which ended in October 2010. In parallel with commissioning and data analysis with the initial detector, LIGO group worked on research and development of the next generation of detectors. Major instrument upgrade from initial to advanced LIGO started in 2010 and lasted until 2014. This thesis describes results of commissioning work done at the LIGO Livingston site from 2013 until 2015 in parallel with and after the installation of the instrument. This thesis also discusses new techniques and tools developed at the 40m prototype including adaptive filtering, estimation of quantization noise in digital filters and design of isolation kits for ground seismometers. The first part of this thesis is devoted to the description of methods for bringing the interferometer into linear regime when collection of data becomes possible. States of longitudinal and angular controls of interferometer degrees of freedom during lock acquisition process and in low noise configuration are discussed in details. Once interferometer is locked and transitioned to low noise regime, instrument produces astrophysics data that should be calibrated to units of meters or strain. The second part of this thesis describes online calibration technique set up in both observatories to monitor the quality of the collected data in real time. Sensitivity analysis was done to understand and eliminate noise sources of the instrument. The coupling of noise sources to gravitational wave channel can be reduced if robust feedforward and optimal feedback control loops are implemented. Static and adaptive feedforward noise cancellation techniques applied to Advanced LIGO interferometers and tested at the 40m prototype are described in the last part of this thesis. Applications of optimal time domain feedback control techniques and estimators to aLIGO control loops are also discussed. Commissioning work is still ongoing at the sites. First science run of advanced LIGO is planned for September 2015 and will last for 3-4 months. This run will be followed by a set of small instrument upgrades that will be installed on a time scale of few months. Second science run will start in spring 2016 and last for about six months. Since current sensitivity of advanced LIGO is already more than a factor of 3 higher compared to initial detectors and keeps improving on a monthly basis, the upcoming science runs have a good chance for the first direct detection of gravitational waves.
An easy-to-build remote laboratory with data transfer using the Internet School Experimental System
NASA Astrophysics Data System (ADS)
Schauer, František; Lustig, František; Dvořák, Jiří; Ožvoldová, Miroslava
2008-07-01
The present state of information communication technology makes it possible to devise and run computer-based e-laboratories accessible to any user with a connection to the Internet, equipped with very simple technical means and making full use of web services. Thus, the way is open for a new strategy of physics education with strongly global features, based on experiment and experimentation. We name this strategy integrated e-learning, and remote experiments across the Internet are the foundation for this strategy. We present both pedagogical and technical reasoning for the remote experiments and outline a simple system based on a server-client approach, and on web services and Java applets. We give here an outline of the prospective remote laboratory system with data transfer using the Internet School Experimental System (ISES) as hardware and ISES WEB Control kit as software. This approach enables the simple construction of remote experiments without building any hardware and virtually no programming, using a paste and copy approach with typical prebuilt blocks such as a camera view, controls, graphs, displays, etc. We have set up and operate at present seven experiments, running round the clock, with more than 12 000 connections since 2005. The experiments are widely used in practical teaching of both university and secondary level physics. The recording of the detailed steps the experimentor takes during the measurement enables detailed study of the psychological aspects of running the experiments. The system is ready for a network of universities to start covering the basic set of physics experiments. In conclusion we summarize the results achieved and experiences of using remote experiments built on the ISES hardware system.
Arsenic exposure in drinking water: an unrecognized health threat in Peru
Sima, Laura; Arias, M Helena Jahuira; Mihalic, Jana; Cabrera, Lilia Z; Danz, David; Checkley, William; Gilman, Robert H
2014-01-01
Abstract Objective To assess the extent of arsenic contamination of groundwater and surface water in Peru and, to evaluate the accuracy of the Arsenic Econo-Quick™ (EQ) kit for measuring water arsenic concentrations in the field. Methods Water samples were collected from 151 water sources in 12 districts of Peru, and arsenic concentrations were measured in the laboratory using inductively-coupled plasma mass spectrometry. The EQ field kit was validated by comparing a subset of 139 water samples analysed by laboratory measurements and the EQ kit. Findings In 86% (96/111) of the groundwater samples, arsenic exceeded the 10 µg/l arsenic concentration guideline given by the World Health Organization (WHO) for drinking water. In 56% (62/111) of the samples, it exceeded the Bangladeshi threshold of 50 µg/l; the mean concentration being 54.5 µg/l (range: 0.1–93.1). In the Juliaca and Caracoto districts, in 96% (27/28) of groundwater samples arsenic was above the WHO guideline; and in water samples collected from the section of the Rímac river running through Lima, all had arsenic concentrations exceeding the WHO limit. When validated against laboratory values, the EQ kit correctly identified arsenic contamination relative to the guideline in 95% (106/111) of groundwater and in 68% (19/28) of surface water samples. Conclusion In several districts of Peru, drinking water shows widespread arsenic contamination, exceeding the WHO arsenic guideline. This poses a public health threat requiring further investigation and action. For groundwater samples, the EQ kit performed well relative to the WHO arsenic limit and therefore could provide a vital tool for water arsenic surveillance. PMID:25177071
Nathalie, Zahra; Hadi, Sibte; Goodwin, William
2012-09-01
Forensic DNA profiling uses a series of commercial kits that co-amplify several loci in one reaction; the products of the PCR are fluorescently labelled and analysed using CE. Before CE, an aliquot of the PCR is mixed with formamide and an internal lane size standard. Using the SGM Plus amplification kit, we have developed two internal non-amplified controls of 80 bp and 380 bp that are labelled with ROX fluorescent dye and added to the PCR. Combined with two internal amplification controls of 90 bp and 410 bp, they provide additional controls for the PCR, electrokinetic injection, and CE and also function as an internal size standard. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rapid Detection of the Varicella Zoster Virus
NASA Technical Reports Server (NTRS)
Lewis, Michelle P.; Harding, Robert
2011-01-01
1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody in blood. Other tests include running a sample in a polymerase chain reaction analyzer, enzyme immunoassay, latex agglutination, indirect fluorescent antibody and fluorescent antibody to membrane antigen assay. These existing tests require laboratory analysis by trained personnel, expensive equipment, invasive procedures and a longer period of time to obtain test results.
Osarogiagbon, Raymond U; Miller, Laura E; Ramirez, Robert A; Wang, Christopher G; O'Brien, Thomas F; Yu, Xinhua; Khandekar, Alim; Schoettle, Glenn P; Robbins, Samuel G; Robbins, Edward T; Gibson, Jeffrey B
2012-08-01
Pathologic examination of mediastinal lymph nodes (MLNs) after resection of non-small-cell lung cancer is critical in the determination of prognosis and postoperative management. Although systematic nodal dissection is recommended, the quality of pathologic lymph-node staging often falls short of recommendations in practice. We tested the feasibility of improving pathologic lymph-node staging of resectable non-small-cell lung cancer by using a prelabeled specimen-collection kit. Case-control study with comparison of 51 resections, using a special lymph-node collection kit, with 51 controls matched for surgeon, extent of resection, pathologist, and T category. Appropriate statistical methods were used for all comparisons. The median number of MLNs examined increased from one in the control group, to six in the case group (p < 0.001). The percentage of resections attaining the National Comprehensive Cancer Network-recommended quality of MLN examination, and the proportion that would have been eligible for recent landmark postresection adjuvant therapy trials increased significantly (p < 0.001). The duration of surgery and postoperative complication rates were similar between cases and controls. Eighteen percent of kit cases had positive MLN, compared with 8% of controls. The use of a specialized specimen-collection kit for MLN examination was feasible, markedly improved MLN staging, and showed a trend toward increased detection of patients with MLN metastasis, with only a modest increase in duration of surgery, and no increase in perioperative morbidity, mortality, or hospital length of stay.
NASA Astrophysics Data System (ADS)
Johari, A. H.; Muslim
2018-05-01
Experiential learning model using simple physics kit has been implemented to get a picture of improving attitude toward physics senior high school students on Fluid. This study aims to obtain a description of the increase attitudes toward physics senior high school students. The research method used was quasi experiment with non-equivalent pretest -posttest control group design. Two class of tenth grade were involved in this research 28, 26 students respectively experiment class and control class. Increased Attitude toward physics of senior high school students is calculated using an attitude scale consisting of 18 questions. Based on the experimental class test average of 86.5% with the criteria of almost all students there is an increase and in the control class of 53.75% with the criteria of half students. This result shows that the influence of experiential learning model using simple physics kit can improve attitude toward physics compared to experiential learning without using simple physics kit.
A strip chart recorder pattern recognition tool kit for Shuttle operations
NASA Technical Reports Server (NTRS)
Hammen, David G.; Moebes, Travis A.; Shelton, Robert O.; Savely, Robert T.
1993-01-01
During Space Shuttle operations, Mission Control personnel monitor numerous mission-critical systems such as electrical power; guidance, navigation, and control; and propulsion by means of paper strip chart recorders. For example, electrical power controllers monitor strip chart recorder pen traces to identify onboard electrical equipment activations and deactivations. Recent developments in pattern recognition technologies coupled with new capabilities that distribute real-time Shuttle telemetry data to engineering workstations make it possible to develop computer applications that perform some of the low-level monitoring now performed by controllers. The number of opportunities for such applications suggests a need to build a pattern recognition tool kit to reduce software development effort through software reuse. We are building pattern recognition applications while keeping such a tool kit in mind. We demonstrated the initial prototype application, which identifies electrical equipment activations, during three recent Shuttle flights. This prototype was developed to test the viability of the basic system architecture, to evaluate the performance of several pattern recognition techniques including those based on cross-correlation, neural networks, and statistical methods, to understand the interplay between an advanced automation application and human controllers to enhance utility, and to identify capabilities needed in a more general-purpose tool kit.
Devesse, Laurence; Ballard, David; Davenport, Lucinda; Riethorst, Immy; Mason-Buck, Gabriella; Syndercombe Court, Denise
2018-05-01
By using sequencing technology to genotype loci of forensic interest it is possible to simultaneously target autosomal, X and Y STRs as well as identity, ancestry and phenotypic informative SNPs, resulting in a breadth of data obtained from a single run that is considerable when compared to that generated with standard technologies. It is important however that this information aligns with the genotype data currently obtained using commercially available kits for CE-based investigations such that results are compatible with existing databases and hence can be of use to the forensic community. In this work, 400 samples were typed using commercially available STR kits and CE, as well as using the Ilumina ForenSeq™ DNA Signature Prep Kit and MiSeq ® FGx to assess concordance of autosomal STRs and population variability. Results show a concordance rate between the two technologies exceeding 99.98% while numerous novel sequence based alleles are described. In order to make use of the sequence variation observed, sequence specific allele frequencies were generated for White British and British Chinese populations. Copyright © 2017 Elsevier B.V. All rights reserved.
Lakshminarayana, Rashmi; Eble, Alex; Bhakta, Preetha; Frost, Chris; Boone, Peter; Elbourne, Diana; Mann, Vera
2013-01-01
The aim of the STRIPES trial was to assess the effectiveness of providing supplementary, remedial teaching and learning materials (and an additional 'kit' of materials for girls) on a composite of language and mathematics test scores for children in classes two, three and four in public primary schools in villages in the Nagarkurnool division of Andhra Pradesh, India. STRIPES was a cluster randomised trial in which 214 villages were allocated either to the supplementary teaching intervention (n = 107) or to serve as controls (n = 107). 54 of the intervention villages were further randomly allocated to receive additional kit for girls. The study was not blinded. Analysis was conducted on the intention to treat principle, allowing for clustering. Composite test scores were significantly higher in the intervention group (107 villages; 2364 children) than in the control group (106 villages; 2014 children) at the end of the trial (mean difference on a percentage scale 15.8; 95% CI 13.1 to 18.6; p<0.001; 0.75 Standard Deviation (SD) difference). Composite test scores were not significantly different in the 54 villages (614 girls) with the additional kits for girls compared to the 53 villages (636 girls) without these kits at the end of the trial (mean difference on a percentage scale 0.5; 95% CI -4.34 to 5.4; p = 0.84). The cost per 0.1 SD increase in composite test score for intervention without kits is Rs. 382.97 (£4.45, $7.13), and Rs.480.59 (£5.58, $8.94) for the intervention with kits. A 18 month programme of supplementary remedial teaching and learning materials had a substantial impact on language and mathematics scores of primary school students in rural Andhra Pradesh, yet providing a 'kit' of materials to girls in these villages did not lead to any measured additional benefit. Controlled-Trials.com ISRCTN69951502.
Patel, Anuj V; Abrams, Samuel M; Gaydos, Charlotte A; Jett-Goheen, Mary; Latkin, Carl A; Rothman, Richard E; Hsieh, Yu-Hsiang
2018-06-14
Up to 60% of patients decline routine HIV testing offer in US emergency departments (EDs). The objective of this study is to determine whether the provision of HIV self-testing (HIVST) kit would increase engagement of HIV testing among these HIV test 'Decliners'. Patients who declined a test offered in an ED-based triage nurse-driven HIV screening programme were enrolled and randomised to either the HIVST or the control group. The patients in the HIVST group received HIVST kits to take home, were encouraged to report test results to an established internet-based STI/HIV testing recruitment website 'I Want the Kit' (IWTK) and received five referral cards for their peers to request HIVST kits from IWTK. The control group received pamphlets about publicly available HIV testing sites. HIV testing from both groups after enrolment was determined via telephone follow-up at 1 month. Testing rate ratio (RR) was determined using χ 2 tests. Fifty-two patients were randomised to the HIVST group and 48 to the control group. Among all 64 patients completing any follow-up, 14/29 (48%) patients in the HIVST group tested themselves at home with the provided kit. Four of these had never had an HIV test. Only 2/35 (6%) in the control group reported having an HIV test after enrolment (RR: 8.45 (95% CI: 2.09 to 34.17)). 57% (8/14) in the HIVST group reported test results to IWTK. Provision of HIVST kits supplements ED-based screening programme and significantly improved engagement of HIV testing among those test 'Decliners' in the ED. NCT03021005, results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Voltage linear transformation circuit design
NASA Astrophysics Data System (ADS)
Sanchez, Lucas R. W.; Jin, Moon-Seob; Scott, R. Phillip; Luder, Ryan J.; Hart, Michael
2017-09-01
Many engineering projects require automated control of analog voltages over a specified range. We have developed a computer interface comprising custom hardware and MATLAB code to provide real-time control of a Thorlabs adaptive optics (AO) kit. The hardware interface includes an op amp cascade to linearly shift and scale a voltage range. With easy modifications, any linear transformation can be accommodated. In AO applications, the design is suitable to drive a range of different types of deformable and fast steering mirrors (FSM's). Our original motivation and application was to control an Optics in Motion (OIM) FSM which requires the customer to devise a unique interface to supply voltages to the mirror controller to set the mirror's angular deflection. The FSM is in an optical servo loop with a wave front sensor (WFS), which controls the dynamic behavior of the mirror's deflection. The code acquires wavefront data from the WFS and fits a plane, which is subsequently converted into its corresponding angular deflection. The FSM provides +/-3° optical angular deflection for a +/-10 V voltage swing. Voltages are applied to the mirror via a National Instruments digital-to-analog converter (DAC) followed by an op amp cascade circuit. This system has been integrated into our Thorlabs AO testbed which currently runs at 11 Hz, but with planned software upgrades, the system update rate is expected to improve to 500 Hz. To show that the FSM subsystem is ready for this speed, we conducted two different PID tuning runs at different step commands. Once 500 Hz is achieved, we plan to make the code and method for our interface solution freely available to the community.
Bidmon, Nicole; Kind, Sonja; Welters, Marij J P; Joseph-Pietras, Deborah; Laske, Karoline; Maurer, Dominik; Hadrup, Sine Reker; Schreibelt, Gerty; Rae, Richard; Sahin, Ugur; Gouttefangeas, Cécile; Britten, Cedrik M; van der Burg, Sjoerd H
2018-07-01
Cell-based assays to monitor antigen-specific T-cell responses are characterized by their high complexity and should be conducted under controlled conditions to lower multiple possible sources of assay variation. However, the lack of standard reagents makes it difficult to directly compare results generated in one lab over time and across institutions. Therefore TCR-engineered reference samples (TERS) that contain a defined number of antigen-specific T cells and continuously deliver stable results are urgently needed. We successfully established a simple and robust TERS technology that constitutes a useful tool to overcome this issue for commonly used T-cell immuno-assays. To enable users to generate large-scale TERS, on-site using the most commonly used electroporation (EP) devices, an RNA-based kit approach, providing stable TCR mRNA and an optimized manufacturing protocol were established. In preparation for the release of this immuno-control kit, we established optimal EP conditions on six devices and initiated an extended RNA stability study. Furthermore, we coordinated on-site production of TERS with 4 participants. Finally, a proficiency panel was organized to test the unsupervised production of TERS at different laboratories using the kit approach. The results obtained show the feasibility and robustness of the kit approach for versatile in-house production of cellular control samples. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Stability of user-friendly blood typing kits stored under typical military field conditions.
Bienek, Diane R; Chang, Cheow K; Charlton, David G
2009-10-01
To help preserve in-theater strength within deployed military units, commercially available, rapid, user-friendly ABO-Rh blood typing kits were evaluated to determine their stability in storage conditions commonly encountered by the warfighter. Methods for environmental exposure testing were based on MIL-STD-810F. When Eldon Home Kits 2511 were exposed to various temperature/relative humidity conditions, the results were comparable to those obtained with the control group and those obtained with industry-standard methods. For the ABO-Rh Combination Blood Typing Experiment Kits, 2 of the exposure treatments rendered them unusable. In addition, a third set of exposure treatments adversely affected the kits, resulting in approximately 30% blood type misclassifications. Collectively, this evaluation of commercial blood typing kits revealed that diagnostic performance can vary between products, lots, and environmental storage conditions.
Loss of c-KIT expression in thyroid cancer cells.
Franceschi, Sara; Lessi, Francesca; Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria
2017-01-01
Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression.
Loss of c-KIT expression in thyroid cancer cells
Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria
2017-01-01
Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression. PMID:28301608
Ecological Risk Assessment of Explosive Residues in Rodents, Reptiles, Amphibians, and Fish
2004-03-01
oligonucleotide primers were designed according to the sequence for pendrin in Mus musculus . PCR was carried out using a Failsafe kit (Epicentre, WI). PCR...Project No. T9700 PERCHLORATE ANALYTICAL Phase V As a calibration curve is run each time a set of samples is analyzed, we routinely include an... Reset FINAL REPORT FY2002 SERDP Project: ER-1235 TABLE OF CONTENTS Topic Page IDENTIFICATION OF PERCHLORATE-CONTAMINATED AND REFERENCE SITES
[Validation of Differential Extraction Kit in forensic sexual assault cases].
Wu, Dan; Cao, Yu; Xu, Yan; He, Bai-Fang; Bi, Gang; Zhou, Huai-Gu
2009-12-01
To evaluate the validity of Differential Extraction Kit in isolating spermatozoa and epithelial cell DNA from mixture samples. Selective lysis of spermatid and epithelial cells combined with paramagnetic particle method were applied to extract the DNA from the mock samples under controlled conditions and forensic case samples, and template DNA were analyzed by STR genotype method. This Differential Extraction Kit is efficient to obtain high quality spermatid and epithelial cell DNA from the mixture samples with different proportion of sperm to epithelial cell. The Differential Extraction Kit can be applied in DNA extraction for mixed stain from forensic sexual assault samples.
Resveratrol Improves Cell Cycle Arrest in Chronic Prostatitis Rats, by C-kit/SCF Suppression.
He, Yi; Zeng, Huizhi; Yu, Yang; Zhang, Jiashu; Zeng, Xiaona; Gong, Fengtao; Liu, Qi; Yang, Bo
2017-08-01
Chronic prostatitis (CP) with complex pathogenesis is difficult for treatment. c-kit has been associated with the control of cell proliferation of prostate cells. This study aims to evaluate the role of resveratrol, an activator of Sirt1, in regulating the expression of c-kit in CP and investigate the consequent effects on cell cycle. Rat model of CP was established through subcutaneous injections of diphtheria-pertussis-tetanus vaccine and subsequently treated with resveratrol. Hematoxylin and eosin staining was performed to identify the histopathological changes in prostates. Western blotting and immunohistochemical staining examined the expression level of c-kit, stem cell factor (SCF), Sirt1, and cell cycle-associated proteins. The model group exhibited severe diffuse chronic inflammation, characterized by leukocyte infiltration and papillary frond protrusion into the gland cavities, and a notable increase in prostatic epithelial height. Gland lumen diameter was also significantly smaller; the activity of c-kit/SCF in the CP rats was increased significantly compared to the control group. Meanwhile, the cell cycle proteins are dysregulated significantly in CP rats. Resveratrol treatment significantly improved these factors by Sirt1 activation. Dysregulation of cell cycle was involved in the pathological processes of CP, which was improved after resveratrol treatment by the downregulation of c-kit/SCF by activating Sirt1.
Nociceptive tuning by stem cell factor/c-Kit signaling.
Milenkovic, Nevena; Frahm, Christina; Gassmann, Max; Griffel, Carola; Erdmann, Bettina; Birchmeier, Carmen; Lewin, Gary R; Garratt, Alistair N
2007-12-06
The molecular mechanisms regulating the sensitivity of sensory circuits to environmental stimuli are poorly understood. We demonstrate here a central role for stem cell factor (SCF) and its receptor, c-Kit, in tuning the responsiveness of sensory neurons to natural stimuli. Mice lacking SCF/c-Kit signaling displayed profound thermal hypoalgesia, attributable to a marked elevation in the thermal threshold and reduction in spiking rate of heat-sensitive nociceptors. Acute activation of c-Kit by its ligand, SCF, resulted in a reduced thermal threshold and potentiation of heat-activated currents in isolated small-diameter neurons and thermal hyperalgesia in mice. SCF-induced thermal hyperalgesia required the TRP family cation channel TRPV1. Lack of c-Kit signaling during development resulted in hypersensitivity of discrete mechanoreceptive neuronal subtypes. Thus, c-Kit can now be grouped with a small family of receptor tyrosine kinases, including c-Ret and TrkA, that control the transduction properties of sensory neurons.
Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young; Koo, Sun Hoe
2012-01-01
Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. The lower detection limits ranged from 10(1) copies/µL to 5×10(1) copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens.
Shin, So Youn; Kwon, Kye Chul; Park, Jong Woo; Kim, Ji Myung; Shin, So Young
2012-01-01
Background Bacterial meningitis is an infectious disease with high rates of mortality and high frequency of severe sequelae. Early identification of causative bacterial and viral pathogens is important for prompt and proper treatment of meningitis and for prevention of life-threatening clinical outcomes. In the present study, we evaluated the value of the Seeplex Meningitis ACE Detection kit (Seegene Inc., Korea), a newly developed multiplex PCR kit employing dual priming oligonucleotide methods, for diagnosing acute meningitis. Methods Analytical sensitivity of the kit was studied using reference strains for each pathogen targeted by the kit, while it's analytical specificity was studied using the human genome DNA and 58 clinically well-identified reference strains. For clinical validation experiment, we used 27 control cerebrospinal fluid (CSF) samples and 78 clinical CSF samples collected from patients at the time of diagnosis of acute meningitis. Results The lower detection limits ranged from 101 copies/µL to 5×101 copies/µL for the 12 viral and bacterial pathogens targeted. No cross-reaction was observed. In the validation study, high detection rate of 56.4% was obtained. None of the control samples tested positive, i.e., false-positive results were absent. Conclusions The Seeplex Meningitis ACE Detection kit showed high sensitivity, specificity, and detection rate for the identification of pathogens in clinical CSF samples. This kit may be useful for rapid identification of important acute meningitis-causing pathogens. PMID:22259778
The stem cell factor (SCF)/c-KIT signalling in testis and prostate cancer.
Cardoso, Henrique J; Figueira, Marília I; Socorro, Sílvia
2017-12-01
The stem cell factor (SCF) is a cytokine that specifically binds the tyrosine kinase receptor c-KIT. The SCF/c-KIT interaction leads to receptor dimerization, activation of kinase activity and initiation of several signal transduction pathways that control cell proliferation, apoptosis, differentiation and migration in several tissues. The activity of SCF/c-KIT system is linked with the phosphatidylinositol 3-kinase (PI3-K), the Src, the Janus kinase/signal transducers and activators of transcription (JAK/STAT), the phospholipase-C (PLC-γ) and the mitogen-activated protein kinase (MAPK) pathways. Moreover, it has been reported that cancer cases display an overactivation of c-KIT due to the presence of gain-of-function mutations or receptor overexpression, which renders c-KIT a tempting target for cancer treatment. In the case of male cancers the most documented activated pathways are the PI3-K and Src, both enhancing abnormal cell proliferation. It is also known that the Src activity in prostate cancer cases depends on the presence of tr-KIT, the cytoplasmic truncated variant of c-KIT that is specifically expressed in tumour tissues and, thus, a very interesting target for drug development. The present review provides an overview of the signalling pathways activated by SCF/c-KIT and discusses the potential application of c-KIT inhibitors for treatment of testicular and prostatic cancers.
Hodi, F Stephen; Corless, Christopher L; Giobbie-Hurder, Anita; Fletcher, Jonathan A; Zhu, Meijun; Marino-Enriquez, Adrian; Friedlander, Philip; Gonzalez, Rene; Weber, Jeffrey S; Gajewski, Thomas F; O'Day, Steven J; Kim, Kevin B; Lawrence, Donald; Flaherty, Keith T; Luke, Jason J; Collichio, Frances A; Ernstoff, Marc S; Heinrich, Michael C; Beadling, Carol; Zukotynski, Katherine A; Yap, Jeffrey T; Van den Abbeele, Annick D; Demetri, George D; Fisher, David E
2013-09-10
Amplifications and mutations in the KIT proto-oncogene in subsets of melanomas provide therapeutic opportunities. We conducted a multicenter phase II trial of imatinib in metastatic mucosal, acral, or chronically sun-damaged (CSD) melanoma with KIT amplifications and/or mutations. Patients received imatinib 400 mg once per day or 400 mg twice per day if there was no initial response. Dose reductions were permitted for treatment-related toxicities. Additional oncogene mutation screening was performed by mass spectroscopy. Twenty-five patients were enrolled (24 evaluable). Eight patients (33%) had tumors with KIT mutations, 11 (46%) with KIT amplifications, and five (21%) with both. Median follow-up was 10.6 months (range, 3.7 to 27.1 months). Best overall response rate (BORR) was 29% (21% excluding nonconfirmed responses) with a two-stage 95% CI of 13% to 51%. BORR was significantly greater than the hypothesized null of 5% and statistically significantly different by mutation status (7 of 13 or 54% KIT mutated v 0% KIT amplified only). There were no statistical differences in rates of progression or survival by mutation status or by melanoma site. The overall disease control rate was 50% but varied significantly by KIT mutation status (77% mutated v 18% amplified). Four patients harbored pretreatment NRAS mutations, and one patient acquired increased KIT amplification after treatment. Melanomas that arise on mucosal, acral, or CSD skin should be assessed for KIT mutations. Imatinib can be effective when tumors harbor KIT mutations, but not if KIT is amplified only. NRAS mutations and KIT copy number gain may be mechanisms of therapeutic resistance to imatinib.
2009-01-01
Background Identical blood samples tested using different kits can give markedly different hepatitis B virus (HBV) DNA levels, which can cause difficulty in the interpretation of viral load. A universal double-stranded DNA control or standard that can be used in all commercial HBV DNA nucleic acid amplification assay kits is urgently needed. By aligning all HBV genotypes (A-H), we found that the surface antigen gene and precore-core gene regions of HBV are the most conserved regions among the different HBV genotypes. We constructed a chimeric fragment by overlapping extension polymerase chain reaction and obtained a 1,349-bp HBVC+S fragment. We then packaged the fragment into lambda phages using a traditional lambda phage cloning procedure. Results The obtained armored DNA was resistant to DNase I digestion and was stable, noninfectious to humans, and could be easily extracted using commercial kits. More importantly, the armored DNA may be used with all HBV DNA nucleic acid amplification assay kits. Conclusions The lambda phage packaging system can be used as an excellent expression platform for armored DNA. The obtained armored DNA possessed all characteristics of an excellent positive control or standard. In addition, this armored DNA is likely to be appropriate for all commercial HBV DNA nucleic acid amplification detection kits. Thus, the constructed armored DNA can probably be used as a universal positive control or standard in HBV DNA assays. PMID:20025781
Hang, Dong; Yuan, Hua; Liu, Li; Wang, Lihua; Miao, Limin; Zhu, Meng; Du, Jiangbo; Dai, Juncheng; Hu, Zhibin; Chen, Ning; Shen, Hongbing; Ma, Hongxia
2017-01-01
KITLG/KIT pathway plays a vital role in multiple types of human cancer including head and neck squamous cell carcinoma (HNSCC). Genetic variations in KITLG and KIT may affect the expression or function of these genes, thereby modifying cancer risk. In this study, we evaluated the association of KITLG and KIT polymorphisms with HNSCC risk among Chinese population. Twenty-two tagging SNPs in KITLG and KIT genes were genotyped in a case-control study with 576 HNSCC patients and 1552 healthy controls. Logistic regression analyses revealed that an upstream SNP rs6554198 [additive model: adjusted odds ratio (OR) = 0.85, 95% confidence interval (CI) = 0.74-0.97, P = 0.019] and two intron SNPs rs2237025 (additive model: adjusted OR = 0.82, 95%CI = 0.70-0.95, P = 0.007), and rs17084687 (additive model: adjusted OR = 0.85, 95%CI = 0.73-0.99, P = 0.042) of KIT were significantly associated with the decreased risk of HNSCC. Combined analysis of the three SNPs showed that subjects carrying the protective alleles had decreased risk of HNSCC in a dose-response manner (P trend = 0.001). Furthermore, interaction analyses revealed a significant multiplicative interaction between rs17084687 and drinking on HNSCC risk (P = 0.012). Luciferase activity assay indicated that the allele A of potentially functional rs6554198 led to significantly lower transcription activity of KIT compared to the risk allele G. Summarily, our findings suggested that SNPs in KIT gene may play a role in genetic susceptibility to HNSCC, which may improve our understanding of the pathogenic mechanisms of this disease. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Xue, Hong; Wang, Feng Yun; Kang, Qian; Tang, Xu Dong
2018-06-20
The proto-oncogene c-kit, as a marker of interstitial cells of Cajal (ICCs) in the gastrointestinal tract, plays an important role in the ICCs. Although limited evidences showed c-kit is present in the colonic epithelium but its roles remain unclear. In the present study, we aimed to investigate the expression, location and function of c-kit in the intestinal epithelium. Immunofluorescence, western blotting, and RT-PCR were performed to detect the expression and location of c-kit in the intestinal mucosa of WT mice. We investigated intestinal epithelial proliferation and migration in vivo by performing 5-Bromodeoxyuridine (BrdU) incorporation and Ki-67 staining in WT and Wads m/m mice. An Ussing chamber with fluorescein-isothiocyanate dextran 4000 was used to detect the transepithelial electric resistance (TER), short circuit current (ISC) and permeability across ex vivo colon segments under control and endotoxaemia conditions. We demonstrated that c-kit was located and expressed in the gut crypt compartment in WT mice, which was demonstrated in the c-kit mutant mice (Wads m/m ). In addition, both the number of proliferating cells and the percentage of the distance migrated were lower in the Wads m/m mice than those in the WT mice. Moreover, the intestinal permeability, TER and tight junction were unaltered in the Wads m/m mice under endotoxic conditions compared with those in both the control condition and the WT mice. Altogether, these observations imply that the expression of c-kit in the colonic epithelium is involved in the proliferation and permeability of the colonic epithelium. Copyright © 2018. Published by Elsevier GmbH.
Mason, Kathleen L; Gonzalez, Michael V; Chung, Chungwon; Mousel, Michelle R; White, Stephen N; Taylor, Joshua B; Scoles, Glen A
2017-09-01
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identified using nested PCR (nPCR) as the gold standard. Negative bovine control sera supplied with the kit were used to calculate % inhibition (%I), designated bovine control ELISA (BcELISA), and this was compared to %I calculated from negative ovine sera derived from hand-raised, pathogen-free sheep, designated ovine control ELISA (OcELISA). The receiver operating characteristics area under the curve was 1.0 with a p value <0.001 regardless of the source of the control sera. The cutoff values for negative BcELISA and OcELISA were <30%I and <27%I, respectively. Our work confirmed that this Anaplasma antibody cELISA kit version 2 can be used with the serum controls supplied in the kit to test for A. ovis antibody in domestic sheep. Furthermore, this work confirmed the historically high infection prevalence (>93%) at the U.S. Sheep Experiment Station (Dubois, Idaho), in spite of efforts to reduce the possibility for iatrogenic transmission there, suggesting high levels of tick-borne transmission.
Dolan, Paul; Rudisill, Caroline
2014-01-01
Financial incentives have been used in a variety of settings to motivate behaviors that might not otherwise be undertaken. They have been highlighted as particularly useful in settings that require a single behavior, such as appointment attendance or vaccination. They also have differential effects based on socioeconomic status in some applications (e.g. smoking). To further investigate these claims, we tested the effect of providing different types of non-cash financial incentives on the return rates of chlamydia specimen samples amongst 16–24 year-olds in England. In 2011 and 2012, we ran a two-stage randomized experiment involving 2988 young people (1489 in Round 1 and 1499 in Round 2) who requested a chlamydia screening kit from Freetest.me, an online and text screening service run by Preventx Limited. Participants were randomized to control, or one of five types of financial incentives in Round 1 or one of four financial incentives in Round 2. We tested the effect of five types of incentives on specimen sample return; reward vouchers of differing values, charity donation, participation in a lottery, choices between a lottery and a voucher and including vouchers of differing values in the test kit prior to specimen return. Financial incentives of any type, did not make a significant difference in the likelihood of specimen return. The more deprived individuals were, as calculated using Index of Multiple Deprivation (IMD), the less likely they were to return a sample. The extent to which incentive structures influenced sample return was not moderated by IMD score. Non-cash financial incentives for chlamydia testing do not seem to affect the specimen return rate in a chlamydia screening program where test kits are requested online, mailed to requestors and returned by mail. They also do not appear more or less effective in influencing test return depending on deprivation level. PMID:24373390
Dolan, Paul; Rudisill, Caroline
2014-03-01
Financial incentives have been used in a variety of settings to motivate behaviors that might not otherwise be undertaken. They have been highlighted as particularly useful in settings that require a single behavior, such as appointment attendance or vaccination. They also have differential effects based on socioeconomic status in some applications (e.g. smoking). To further investigate these claims, we tested the effect of providing different types of non-cash financial incentives on the return rates of chlamydia specimen samples amongst 16-24 year-olds in England. In 2011 and 2012, we ran a two-stage randomized experiment involving 2988 young people (1489 in Round 1 and 1499 in Round 2) who requested a chlamydia screening kit from Freetest.me, an online and text screening service run by Preventx Limited. Participants were randomized to control, or one of five types of financial incentives in Round 1 or one of four financial incentives in Round 2. We tested the effect of five types of incentives on specimen sample return; reward vouchers of differing values, charity donation, participation in a lottery, choices between a lottery and a voucher and including vouchers of differing values in the test kit prior to specimen return. Financial incentives of any type, did not make a significant difference in the likelihood of specimen return. The more deprived individuals were, as calculated using Index of Multiple Deprivation (IMD), the less likely they were to return a sample. The extent to which incentive structures influenced sample return was not moderated by IMD score. Non-cash financial incentives for chlamydia testing do not seem to affect the specimen return rate in a chlamydia screening program where test kits are requested online, mailed to requestors and returned by mail. They also do not appear more or less effective in influencing test return depending on deprivation level. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
The stem cell growth factor receptor KIT is not expressed on interstitial cells in bladder.
Gevaert, Thomas; Ridder, Dirk De; Vanstreels, Els; Daelemans, Dirk; Everaerts, Wouter; Aa, Frank Van Der; Pintelon, Isabel; Timmermans, Jean-Pierre; Roskams, Tania; Steiner, Clara; Neuhaus, Jochen
2017-06-01
The mast/stem cell growth factor receptor KIT has long been assumed to be a specific marker for interstitial cells of Cajal (ICC) in the bladder, with possible druggable perspectives. However, several authors have challenged the presence of KIT + ICC in recent years. The aim of this study was therefore to attempt to clarify the conflicting reports on KIT expression in the bladder of human beings, rat, mouse and guinea pig and to elucidate the possible role of antibody-related issues and interspecies differences in this matter. Fresh samples were obtained from human, rat, mouse and guinea pig cystectomies and processed for single/double immunohistochemistry/immunofluorescence. Specific antibodies against KIT, mast cell tryptase (MCT), anoctamin-1 (ANO1) and vimentin were used to characterize the cell types expressing KIT. Gut (jejunum) tissue was used as an external antibody control. Our results revealed KIT expression on mast cells but not on ICC in human, rat, mouse and guinea pig bladder. Parallel immunohistochemistry showed KIT expression on ICC in human, rat, mouse and guinea pig gut, which confirmed the selectivity of the KIT antibody clones. In conclusion, we have shown that KIT + cells in human, rat, mouse and guinea pig bladder are mast cells and not ICC. The present report is important as it opposes the idea that KIT + ICC are present in bladder. In this perspective, functional concepts of KIT + ICC being involved in sensory and/or motor aspects of bladder physiology should be revised. © 2016 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Impact and Effectiveness of a Stand-Alone NRT Starter Kit in a Statewide Tobacco Cessation Program.
Kerr, Amy N; Schillo, Barbara A; Keller, Paula A; Lachter, Randi B; Lien, Rebecca K; Zook, Heather G
2018-01-01
To examine 2-week nicotine replacement therapy (NRT) starter kit quit outcomes and predictors and the impact of adding this new service on treatment reach. Observational study of a 1-year cohort of QUITPLAN Services enrollees using registration and utilization data and follow-up outcome survey data of a subset of enrollees who received NRT starter kits. ClearWay Minnesota's QUITPLAN Services provides a quit line that is available to uninsured and underinsured Minnesotans and NRT starter kits (a free 2-week supply of patches, gum, or lozenges) that are available to all Minnesota tobacco users. A total of 15 536 adult QUITPLAN Services enrollees and 818 seven-month follow-up survey NRT starter kit respondents. Treatment reach for all services and tobacco quit outcomes and predictors for starter kit recipients. Descriptive analyses, χ 2 analyses, and logistic regression. Treatment reach increased 3-fold after adding the 2-week NRT starter kit service option to QUITPLAN Services compared to the prior year (1.86% vs 0.59%). Among all participants enrolling in QUITPLAN services during a 1-year period, 83.8% (13 026/15 536) registered for a starter kit. Among starter kit respondents, 25.6% reported being quit for 30 days at the 7-month follow-up. After controlling for other factors, using all NRT and selecting more cessation services predicted quitting. An NRT starter kit brought more tobacco users to QUITPLAN services, demonstrating interest in cessation services separate from phone counseling. The starter kit produced high quit rates, comparable to the quit line in the same time period. Cessation service providers may want to consider introducing starter kits to reach more tobacco users and ultimately improve population health.
Lyberg, Katarina; Ali, Hani Abdulkadir; Grootens, Jennine; Kjellander, Matilda; Tirfing, Malin; Arock, Michel; Hägglund, Hans; Nilsson, Gunnar; Ungerstedt, Johanna
2017-02-07
Systemic mastocytosis (SM) is a clonal bone marrow disorder, where therapeutical options are limited. Over 90% of the patients carry the D816V point mutation in the KIT receptor that renders this receptor constitutively active. We assessed the sensitivity of primary mast cells (MC) and mast cell lines HMC1.2 (D816V mutated), ROSA (KIT WT) and ROSA (KIT D816V) cells to histone deacetylase inhibitor (HDACi) treatment. We found that of four HDACi, suberoyl anilide hydroxamic acid (SAHA) was the most effective in killing mutated MC. SAHA downregulated KIT, followed by major MC apoptosis. Primary SM patient MC cultured ex vivo were even more sensitive to SAHA than HMC1.2 cells, whereas primary MC from healthy subjects were less affected. There was a correlation between cell death and SM disease severity, where cell death was more pronounced in the case of aggressive SM, with almost 100% cell death among MC from the mast cell leukemia patient. Additionally, ROSA (KIT D816V) was more affected by HDACi than ROSA (KIT WT) cells. Using ChIP qPCR, we found that the level of active chromatin mark H3K18ac/H3 decreased significantly in the KIT region. This epigenetic silencing was seen only in the KIT region and not in control genes upstream and downstream of KIT, indicating that the downregulation of KIT is exerted by specific epigenetic silencing. In conclusion, KIT D816V mutation sensitized MC to HDACi mediated killing, and SAHA may be of value as specific treatment for SM, although the specific mechanism of action requires further investigation.
Lyberg, Katarina; Ali, Hani Abdulkadir; Grootens, Jennine; Kjellander, Matilda; Tirfing, Malin; Arock, Michel; Hägglund, Hans
2017-01-01
Systemic mastocytosis (SM) is a clonal bone marrow disorder, where therapeutical options are limited. Over 90% of the patients carry the D816V point mutation in the KIT receptor that renders this receptor constitutively active. We assessed the sensitivity of primary mast cells (MC) and mast cell lines HMC1.2 (D816V mutated), ROSA (KIT WT) and ROSA (KIT D816V) cells to histone deacetylase inhibitor (HDACi) treatment. We found that of four HDACi, suberoyl anilide hydroxamic acid (SAHA) was the most effective in killing mutated MC. SAHA downregulated KIT, followed by major MC apoptosis. Primary SM patient MC cultured ex vivo were even more sensitive to SAHA than HMC1.2 cells, whereas primary MC from healthy subjects were less affected. There was a correlation between cell death and SM disease severity, where cell death was more pronounced in the case of aggressive SM, with almost 100% cell death among MC from the mast cell leukemia patient. Additionally, ROSA (KIT D816V) was more affected by HDACi than ROSA (KIT WT) cells. Using ChIP qPCR, we found that the level of active chromatin mark H3K18ac/H3 decreased significantly in the KIT region. This epigenetic silencing was seen only in the KIT region and not in control genes upstream and downstream of KIT, indicating that the downregulation of KIT is exerted by specific epigenetic silencing. In conclusion, KIT D816V mutation sensitized MC to HDACi mediated killing, and SAHA may be of value as specific treatment for SM, although the specific mechanism of action requires further investigation. PMID:28038453
Le Dimna, M; Vrancken, R; Koenen, F; Bougeard, S; Mesplède, A; Hutet, E; Kuntz-Simon, G; Le Potier, M F
2008-01-01
Two real-time RT-PCR kits, developed by LSI (TaqVet CSF) and ADIAGENE (Adiavet CSF), obtained an agreement to be commercialised in France, subject to conditions, defined by the French Classical Swine Fever (CSF) National Reference Laboratory. The producers were asked to introduce an internal control to check the RNA extraction efficacy. The different criteria assessed were sensitivity, "pestivirus specificity", reproducibility and ease of handling, using 189 different samples. These samples were either CSFV inactivated strains or blood/serum/organs collected from CSFV experimentally infected pigs or naturally infected wild boars. The reproducibility of the assays was confirmed by the analysis of a batch-to-batch panel control that was used for inter-laboratory tests involving nine laboratories. The two kits were also tested for the use in mass diagnostics and the results proved the kits to be suited using pools of blood, serum and tonsils. Moreover, a field evaluation, carried out on spleen samples collected from the CSF surveillance of wild boars in an area known to be infected and from domestic pigs at a slaughterhouse, confirmed the high sensitivity and specificity of the two kits. This step-by-step evaluation procedure confirmed that the two commercial CSF real-time RT-PCR kits have a higher predictive value than the current diagnostic standard, Virus Isolation.
Use of a Novel Airway Kit and Simulation in Resident Training on Emergent Pediatric Airways.
Melzer, Jonathan M; Hamersley, Erin R S; Gallagher, Thomas Q
2017-06-01
Objective Development of a novel pediatric airway kit and implementation with simulation to improve resident response to emergencies with the goal of improving patient safety. Methods Prospective study with 9 otolaryngology residents (postgraduate years 1-5) from our tertiary care institution. Nine simulated pediatric emergency airway drills were carried out with the existing system and a novel portable airway kit. Response times and time to successful airway control were noted with both the extant airway system and the new handheld kit. Results were analyzed to ensure parametric data and compared with t tests. A Bonferroni adjustment indicated that an alpha of 0.025 was needed for significance. Results Use of the airway kit significantly reduced the mean time of resident arrival by 47% ( P = .013) and mean time of successful intubation by 50% ( P = .007). Survey data indicated 100% improved resident comfort with emergent airway scenarios with use of the kit. Discussion Times to response and meaningful intervention were significantly reduced with implementation of the handheld airway kit. Use of simulation training to implement the new kit improved residents' comfort and airway skills. This study describes an affordable novel mobile airway kit and demonstrates its ability to improve response times. Implications for Practice The low cost of this airway kit makes it a tenable option even for smaller hospitals. Simulation provides a safe and effective way to familiarize oneself with novel equipment, and, when possible, realistic emergent airway simulations should be used to improve provider performance.
Unremitting Cell Proliferation in the Secretory Phase of Eutopic Endometriosis
Franco-Murillo, Yanira; Miranda-Rodríguez, José Antonio; Rendón-Huerta, Erika; Montaño, Luis F.; Cornejo, Gerardo Velázquez; Gómez, Lucila Poblano; Valdez-Morales, Francisco Javier; Gonzalez-Sanchez, Ignacio
2014-01-01
Objective: Endometriosis is linked to altered cell proliferation and stem cell markers c-kit/stem cell factor (SCF) in ectopic endometrium. Our aim was to investigate whether c-kit/SCF also plays a role in eutopic endometrium. Design: Eutopic endometrium obtained from 35 women with endometriosis and 25 fertile eumenorrheic women was analyzed for in situ expression of SCF/c-kit, Ki67, RAC-alpha serine/threonine-protein kinase (Akt), phosphorylated RAC-alpha serine/threonin-protein kinase (pAkt), Glycogen synthase kinase 3 beta (GSK3β), and phosphorylated glycogen synthase kinase 3 beta (pGSK3β), throughout the menstrual cycle. Results: Expression of Ki67 and SCF was higher in endometriosis than in control tissue (P < .05) and greater in secretory rather than proliferative (P < .01) endometrium in endometriosis. Expression of c-kit was also higher in endometriosis although similar in both phases. Expression of Akt and GSK3β was identical in all samples and cycle phases, whereas pAkt and pGSK3β, opposed to control tissue, remained overexpressed in the secretory phase in endometriosis. Conclusion: Unceasing cell proliferation in the secretory phase of eutopic endometriosis is linked to deregulation of c-kit/SCF-associated signaling pathways. PMID:25194152
He, Yi; Zeng, Huizhi; Yu, Yang; Zhang, Jiashu; Zeng, Xiaona; Gong, Fengtao; Duan, Xingping; Liu, Qi; Yang, Bo
2017-07-19
The regulation mechanism of inflammation inducing prostate carcinogenesis remains largely unknown. Therefore, we investigated the role of the c-kit/SCF pathway, which has been associated with the control of prostate carcinogenesis, in chronic prostatitis (CP) rats and evaluated the anti-prostatitis effect of resveratrol. We performed hemolysin and eosin staining to evaluate the histopathological changes in prostates. Multiple approaches evaluated the expression levels of c-kit, stem cell factor (SCF), Sirt1, and carcinogenesis-associated proteins. The CP group exhibited severe diffuse chronic inflammation. Meanwhile, the prostate cells appeared atypia; the activity of c-kit/SCF was upregulated, and carcinogenesis-associated proteins are dysregulated significantly in CP rats. Resveratrol treatment significantly improved these factors by Sirt1 activation. In summary, CP could further cause prostate carcinogenesis, which may be associated with activated c-kit/SCF signaling. Resveratrol treatment could improve the progression of CP via the downregulation of c-kit/SCF by activating Sirt1.
NASA Astrophysics Data System (ADS)
Solano-Altamirano, J. M.; Hernández-Pérez, Julio M.
2015-11-01
DensToolKit is a suite of cross-platform, optionally parallelized, programs for analyzing the molecular electron density (ρ) and several fields derived from it. Scalar and vector fields, such as the gradient of the electron density (∇ρ), electron localization function (ELF) and its gradient, localized orbital locator (LOL), region of slow electrons (RoSE), reduced density gradient, localized electrons detector (LED), information entropy, molecular electrostatic potential, kinetic energy densities K and G, among others, can be evaluated on zero, one, two, and three dimensional grids. The suite includes a program for searching critical points and bond paths of the electron density, under the framework of Quantum Theory of Atoms in Molecules. DensToolKit also evaluates the momentum space electron density on spatial grids, and the reduced density matrix of order one along lines joining two arbitrary atoms of a molecule. The source code is distributed under the GNU-GPLv3 license, and we release the code with the intent of establishing an open-source collaborative project. The style of DensToolKit's code follows some of the guidelines of an object-oriented program. This allows us to supply the user with a simple manner for easily implement new scalar or vector fields, provided they are derived from any of the fields already implemented in the code. In this paper, we present some of the most salient features of the programs contained in the suite, some examples of how to run them, and the mathematical definitions of the implemented fields along with hints of how we optimized their evaluation. We benchmarked our suite against both a freely-available program and a commercial package. Speed-ups of ˜2×, and up to 12× were obtained using a non-parallel compilation of DensToolKit for the evaluation of fields. DensToolKit takes similar times for finding critical points, compared to a commercial package. Finally, we present some perspectives for the future development and growth of the suite.
Use of anoctamin 1 (ANO1) to evaluate interstitial cells of Cajal in Hirschsprung's disease.
Coyle, David; Kelly, Danielle A M; O'Donnell, Anne Marie; Gillick, John; Puri, Prem
2016-02-01
Interstitial cells of Cajal (ICCs) are pacemaker cells involved in facilitating neurotransmission and the generation of slow electrical waves necessary for colonic peristalsis. Their distribution has been found to be abnormal in the aganglionic and ganglionic colon in Hirschsprung's disease (HSCR) using c-kit-labelling. Anoctamin-1 (ANO1) is a Ca(2+)-activated Cl(-) channel thought to be specifically expressed on ICCs. Unlike c-kit, it plays a key role in ICC pacemaker activity. We aimed to investigate the utility of ANO1 in evaluating the colonic ICC network in HSCR. We collected full-length pull-through specimens from children with HSCR (n = 10). Control colon specimens were collected at colostomy closure in children with anorectal malformation (n = 6). The distribution of ANO1 and c-kit expression was evaluated using immunofluorescence and confocal microscopy. ANO1 expression was quantified using Western blot analysis. ANO1 was not expressed on 23 % of c-kit immuno-positive cells in the circular muscle; however, 100 % of ANO1-positive ICCs were c-kit positive. The distribution of ANO1-positive ICCs was sparse in aganglionic colon, with a modest reduction in ICCs seen in the ganglionic colon in HSCR compared to controls (p = 0.044). ANO1 protein expression was reduced in aganglionic colon but similar in ganglionic colon relative to controls. ANO1 is preferential to c-kit in evaluating the ICC network in HSCR due to its specificity and functional importance. Abnormal distribution of ANO1-positive ICCs in the ganglionic colon in HSCR may contribute to persistent bowel symptoms in some patients after pull-through surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
This software is an iOS (Apple) Augmented Reality (AR) application that runs on the iPhone and iPad. It is designed to scan in a photograph or graphic and "play" an associated video. This release, SNLSimMagic, was built using Wikitude Augmented Reality (AR) software development kit (SDK) integrated into Apple iOS SDK application and the Cordova libraries. These codes enable the generation of runtime targets using cloud recognition and developer-defined target features which are then accessed by means of a custom application.
Evaluation of sequencing approaches for high-throughput ...
Whole-genome in vitro transcriptomics has shown the capability to identify mechanisms of action and estimates of potency for chemical-mediated effects in a toxicological framework, but with limited throughput and high cost. We present the evaluation of three toxicogenomics platforms for potential application to high-throughput screening: 1. TempO-Seq utilizing custom designed paired probes per gene; 2. Targeted sequencing (TSQ) utilizing Illumina’s TruSeq RNA Access Library Prep Kit containing tiled exon-specific probe sets; 3. Low coverage whole transcriptome sequencing (LSQ) using Illumina’s TruSeq Stranded mRNA Kit. Each platform was required to cover the ~20,000 genes of the full transcriptome, operate directly with cell lysates, and be automatable with 384-well plates. Technical reproducibility was assessed using MAQC control RNA samples A and B, while functional utility for chemical screening was evaluated using six treatments at a single concentration after 6 hr in MCF7 breast cancer cells: 10 µM chlorpromazine, 10 µM ciclopriox, 10 µM genistein, 100 nM sirolimus, 1 µM tanespimycin, and 1 µM trichostatin A. All RNA samples and chemical treatments were run with 5 technical replicates. The three platforms achieved different read depths, with the TempO-Seq having ~34M mapped reads per sample, while TSQ and LSQ averaged 20M and 11M aligned reads per sample, respectively. Inter-replicate correlation averaged ≥0.95 for raw log2 expression values i
ERIC Educational Resources Information Center
Sarmiento, Kelly; Mitchko, Jane; Klein, Cynthia; Wong, Sharon
2010-01-01
Background: To reduce the number of sports-related concussions, the Centers for Disease Control and Prevention (CDC), with the support of partners and experts in the field, has developed a tool kit for high school coaches with practical, easy-to-use concussion-related information. This study explores the success of the tool kit in changing…
Design of an NF-kB Activation-Coupled Apoptotic Molecule for Prostate Cancer Therapy
2008-07-31
p65-LS) hetero-dimer. We used this immunocomplex for caspase activity assay using a colorimetric caspase activity assay kit ( Biovision ). The...by a Caspase-3 colorimetric assay kit ( BioVision ). The purified Caspase-3 (10 ng) was used as a positive control in the assay. As shown in Figure...caspase-3 activity assay with a caspase-3 activity assay kit ( BioVision ). The activity of caspase-3 is in an arbitrary unit. 16 c), co-expressed
Culbertson holds a syringe kit in Destiny during Expedition Three
2001-08-29
ISS003-E-5475 (29 August 2001) --- Astronaut Frank L. Culbertson, Expedition Three mission commander, holds a syringe kit to be used in the Quad Tissue Culture Module Assemblies (QTCMA) for the Biotechnology Specimen Temperature Controller (BSTC) experiment in the U.S. Laboratory.
Antonescu, Cristina R; Viale, Agnes; Sarran, Lisa; Tschernyavsky, Sylvia J; Gonen, Mithat; Segal, Neil H; Maki, Robert G; Socci, Nicholas D; DeMatteo, Ronald P; Besmer, Peter
2004-05-15
Gastrointestinal stromal tumors (GISTs) are specific KIT expressing and KIT-signaling driven mesenchymal tumors of the human digestive tract, many of which have KIT-activating mutations. Previous studies have found a relatively homogeneous gene expression profile in GIST, as compared with other histological types of sarcomas. Transcriptional heterogeneity within clinically or molecularly defined subsets of GISTs has not been previously reported. We tested the hypothesis that the gene expression profile in GISTs might be related to KIT genotype and possibly to other clinicopathological factors. An HG-U133A Affymetrix chip (22,000 genes) platform was used to determine the variability of gene expression in 28 KIT-expressing GIST samples from 24 patients. A control group of six intra-abdominal leiomyosarcomas was also included for comparison. Statistical analyses (t tests) were performed to identify discriminatory gene lists among various GIST subgroups. The levels of expression of various GIST subsets were also linked to a modified version of the growth factor/KIT signaling pathway to analyze differences at various steps in signal transduction. Genes involved in KIT signaling were differentially expressed among wild-type and mutant GISTs. High gene expression of potential drug targets, such as VEGF, MCSF, and BCL2 in the wild-type group, and Mesothelin in exon 9 GISTs were found. There was a striking difference in gene expression between stomach and small bowel GISTs. This finding was validated in four separate tumors, two gastric and two intestinal, from a patient with familial GIST with a germ-line KIT W557R substitution. GISTs have heterogeneous gene expression depending on KIT genotype and tumor location, which is seen at both the genomic level and the KIT signaling pathway in particular. These findings may explain their variable clinical behavior and response to therapy.
Roberts, Kathryn G.; Smith, Amanda M.; McDougall, Fiona; Carpenter, Helen; Horan, Martin; Neviani, Paolo; Powell, Jason A.; Thomas, Daniel; Guthridge, Mark A.; Perrotti, Danilo; Sim, Alistair T.R.; Ashman, Leonie K.; Verrills, Nicole M.
2010-01-01
Oncogenic mutations of the receptor tyrosine kinase c-KIT play an important role in the pathogenesis of gastrointestinal stromal tumors (GIST), systemic mastocytosis, and some acute myeloid leukemias (AML). Whilst juxtamembrane mutations commonly detected in GIST are sensitive to tyrosine kinase inhibitors, the kinase domain mutations frequently encountered in systemic mastocytosis and AML confer resistance and are largely unresponsive to targeted inhibition by the existing agent imatinib. In this study we show that myeloid cells expressing activated c-KIT mutants that are imatinib-sensitive (V560G) or –resistant (D816V) can inhibit the tumor suppressor activity of protein phosphatase 2A (PP2A). This effect was associated with reduced expression of PP2A structural (A) and regulatory subunits (B55α; B56α; B56γ and B56δ). Overexpression of PP2A-Aα in D816V c-KIT cells induced apoptosis and inhibited proliferation. In addition, pharmacological activation of PP2A by FTY720 reduced proliferation, inhibited clonogenic potential and induced apoptosis of mutant c-KIT+ cells, whilst having no effect on WT c-KIT cells or empty vector controls. FTY720 treatment caused dephosphorylation of the D816V c-KIT receptor and its downstream signaling targets pAkt, pSTAT5 and pERK1/2. Additionally, in vivo administration of FTY720 delayed the growth of V560G and D816V c-KIT tumors, inhibited splenic and bone marrow infiltration, and prolonged survival. Our findings show that PP2A inhibition is essential for c-KIT-mediated tumorigenesis, and that reactivating PP2A may offer an attractive strategy to treat drug-resistant c-KIT+ cancers. PMID:20551067
Zhao, Meng-Chuan; Li, Gui-Xia; Zhang, Dan; Zhou, Hang-Yu; Wang, Hao; Yang, Shuo; Wang, Le; Feng, Zhi-Shan; Ma, Xue-Jun
2017-06-01
Respiratory Pathogen 13 Detection Kit (13× kit) is able to simultaneously detect 11 respiratory viruses, Mycoplasma pneumoniae (MP) and Chlamydia in a single reaction. Using 572 Nasopharyngeal aspirates collected from hospitalized children, the clinical performance of 13× kit for detecting 11 respiratory viruses was evaluated in comparison with a routinely used 2-tube multiplex reverse transcription PCR assay (2-tube assay) at provincial Centers for Disease Control and Prevention in China. The clinical performance of 13× kit for detecting MP and Chlamydia was evaluated by commercial real-time quantitative PCR (qPCR) kits or sequencing. For tested viruses, the assay concordance was 95.98% and the kappa coefficient was 0.89. All the MP and Chlamydia positive samples detected by 13× kit were confirmed as true positives. The utilization of the 13× kit in clinical settings will be helpful for doctors to assess clinical outcome according to virus type or multiple infections, and to limit the use of antibiotics. Copyright © 2017 Elsevier Inc. All rights reserved.
You Be the Chemist [Multimedia Kit].
ERIC Educational Resources Information Center
National Association of Chemical Distributors, Arlington, VA. Educational Foundation.
This multimedia kit includes a teacher's manual, video, and activity packet. The unique interactive course uses safe, controlled dynamic experiments to teach kids about chemistry, the proper handling of chemicals, and responsible product stewardship. Students are asked to hypothesize about chemical substances, collect and analyze data, and share…
An indigenously developed nitrite kit to aid in the diagnosis of urinary tract infection.
Sood, S; Upadhyaya, P; Kapil, A; Lodha, R; Jain, Y; Bagga, A
1999-09-01
To evaluate the utility of an indigenously developed nitrite kit for the rapid diagnosis of urinary tract infection (UTI) METHODS: 1018 urine specimens were collected from all cases where there was clinical suspicion of UTI. Samples were cultured as per standard microbiological protocol. Presence of nitrites was indicated by the development of purple color on addition of color developing solution and compared with the set of graded positive and negative controls also provided in the Kit. The results of the nitrite kit were compared with the semi-quantitative urine culture as the gold standard. The sensitivity, specificity, positive predictive and negative predictive values were 47%, 87%, 31% and 93%, respectively. Nitrite kit as a screening test can decrease the work load in the clinical bacteriology laboratory. More importantly in a field set up that is devoid of culture facilities, it can be used to correctly predict the absence of UTI.
Zheng, Si-Li; Li, Zhi-Yong; Zhang, Zheng; Wang, Dong-Sheng; Xu, Jian; Miao, Chao-Yu
2018-04-01
Metrnl is a newly discovered secreted protein with neurotrophic activity and metabolic effect, while in earlier studies its circulating level in human was not explored. We evaluated two commercial enzyme-linked immunosorbent assay kits (DY7867-05, R&D Systems and SK00478-02, Aviscera Bioscience) for the detection of human circulating Metrnl. The DY7867-05 kit showed superiority over the SK00478-02 kit since it generated better curve fitting degree, smaller variation among tests, higher inter-assay reproducibility and better specificity, and could effectively detect human Metrnl in six types of blood samples. Subsequent analysis was performed using the DY7867-05 kit. Sample storage conditions were investigated. No gender difference in circulating Metrnl levels was found, while people with newly diagnosed type 2 diabetes mellitus (T2DM) had significantly lower Metrnl levels compared to the healthy controls.
Midrio, P; Faussone-Pellegrini, M S; Vannucchi, M G; Flake, A W
2004-10-01
A pacemaker system is required for peristalsis generation. The interstitial cells of Cajal (ICC) are considered the intestinal pacemaker, and are identified by expression of the c-kit gene--encoded protein. Gastroschisis is characterized by a severe gastrointestinal dysmotility in newborns. In spite of this clinical picture, few studies have focused on smooth muscle cells (SMC) morphology and none on ICC. Therefore, their morphology has been studied in fetuses at term in the rat model of gastroschisis. At 18.5 day's gestation (E18.5), 10 rat fetuses were killed, 10 underwent surgical creation of gastroschisis, and 10 underwent manipulation only. The small intestine of the latter 2 groups was harvested at E21.5. Specimens were processed for H&E, c-kit and actin (alpha smooth muscle antibody [alpha-SMA]) immunohistochemistry, and transmission electron microscopy (TEM). In the controls, SMC were c-kit+ and alpha-SMA+, with labeling intensity increasing by age. At E21.5, some cells around the Auerbach's plexus were more intensely c-kit+, and differentiating ICC were seen under TEM at this level. Gastroschisis fetuses had no c-kit+ cells referable to ICC. In the more damaged loops, SMC were very faintly c-kit+ and alpha-SMA+. Under TEM, there were few differentiated SMC and no presumptive ICC. In the less-damaged loops, SMC were faintly c-kit+ and alpha-SMA+ and had ultrastructural features intermediate between those of E18.5 and E21.5 controls; ICC were very immature. ICC and SMC differentiation is delayed in gastroschisis with the most damaged loops showing the most incomplete picture. These findings might help in understanding the delayed onset of peristalsis and the variable time-course of the recover seen in babies affected by gastroschisis.
Zahra, Nathalie; Goodwin, William
2016-01-01
Biological samples recovered for forensic investigations are often degraded and/or have low amounts of DNA; in addition, in some instances the samples may be contaminated with chemicals that can act as PCR inhibitors. As a consequence this can make interpretation of the results challenging with the possibility of having partial profiles and false negative results. Because of the impact of DNA analysis on forensic investigations, it is important to monitor the process of DNA profiling, in particular the amplification reaction. In this chapter we describe a method for the in-house generation and use of internal amplification controls (IACs) with DNA profiling kits to monitor the success of the PCR proces. In the example we show the use of the SGM Plus® kit. These controls can also be used to aid the interpretation of the DNA profile.
Souza Freitas, Valéria; de Andrade Santos, Pedro Paulo; de Almeida Freitas, Roseana; Pereira Pinto, Leão; de Souza, Lélia Batista
2011-09-01
The aim of this study was to evaluate mast cell (MC) density and migration and their association with matrix metalloproteinase (MMP) 9 expression in squamous cell carcinoma (SCC) and actinic cheilitis (AC). Tryptase, c-Kit, and MMP-9 expression was evaluated in 20 cases of SCC, 20 cases of AC, and 7 cases of normal lip (control samples) by immunohistochemistry techniques. Tryptase(+) and c-Kit(+) MC densities were significantly higher in SCCs than in ACs and control samples (P < .001). However, no significant difference was found when comparing tryptase(+) and c-Kit(+) MC densities between ACs and control samples (P values .185 and .516, respectively). MMP-9 was strongly expressed in SCCs and moderately expressed in ACs and control samples. A highly significant association was found between tryptase(+) MC density and the expression of MMP-9 (P < .001). The increase in MC density associated with the strong expression of MMP-9 may favor SCC progression. Copyright © 2011 Mosby, Inc. All rights reserved.
National High Blood Pressure 12-Month Kit. May 1988.
ERIC Educational Resources Information Center
National Heart and Lung Inst. (DHHS/NIH), Bethesda, MD. National High Blood Pressure Education Program.
Part I of this kit provides information for program planners and health professionals on ways to overcome barriers to health care among the medically underserved, promote high blood pressure control through the media and other community channels, and improve adherence to treatment among hypertensive patients. It lists additional resources for…
ERIC Educational Resources Information Center
Woito, Robert, Ed.
This kit presents a comprehensive introduction for students to arms control and disarmament issues. Included are copies of published and unpublished articles for each topic. Section I provides a self-survey to enable students to assess their own attitudes, values, and knowledge. The survey poses questions for which students select one of several…
Xu, Ruoyang; Shieh, Y Carol; Stewart, Diana S
2017-01-01
Real-time reverse transcriptase-polymerase chain reaction (RT-PCR) offers a rapid and sensitive molecular method for detection of enteric viruses. Unfortunately, these assays are often hampered by the low virus titre found in foods and PCR inhibition due to matrix carryover during RNA extraction. Four commercial RNA extraction kits (Qiagen's QIAamp Viral RNA Mini and UltraSens Virus kits, MoBio UltraClean Tissue & Cells RNA Isolation kit, and Ambion MagMAX Viral RNA Isolation kit) were evaluated for their ability to extract and purify MS2 bacteriophage RNA, an enteric virus surrogate, from inoculated green onions, a food which has been associated with viral gastroenteritis outbreaks. Inoculated green onion wash concentrates and green onion pieces with and without Qiagen QIAshredder homogenization were assayed in the kit comparison. MS2 detection and PCR inhibition were evaluated using a duplex real-time RT-PCR for MS2 and an exogenous internal amplification control (IAC) assay. Without homogenization, MS2 inoculated at 40pfu/g was detected in at least 4 lots of green onion wash concentrates using the silica-membrane spin-column kits. Inhibition was a factor for the magnetic silica-based MagMAX kit, which resulted in detection of MS2 in 1 of 5. Addition of QIAshredder homogenization prior to extraction did not adversely affect the silica-membrane kit results but improved the MS2 detection by MagMAX to 5 of 5 lots. Use of a 1:10 dilution of primary RNA extracts also improved detection. The QIAamp Viral RNA Mini and MagMAX kits were further compared for detection of MS2 from green onion pieces inoculated at 20 and 5pfu/g. Using homogenization, the MagMAX kit detected 20pfu/g in only 1 of 2 green onion lots, whereas the QIAamp Viral RNA kit detected 2 of 2 lots at 5 pfu/g without homogenization. Published by Elsevier B.V.
Miao, Bin; Zhang, Shuwen; Wang, Hong; Yang, Tiecheng; Zhou, Deshan; Wang, Bao-en
2013-08-01
The purpose of this study was to investigate the mechanism by which magnolol treatment prevents lipopolysaccharide (LPS)-induced septic dysmotility in mice. Sepsis was induced by intravenous tail vein injection of LPS (4 mg/kg body weight). Animals were divided into three groups: the magnolol-treated septic group, the placebo-treated septic group, and the control group. Intestinal transit and circular smooth muscle contraction were measured 12 h after LPS injection, and immunocytochemisty was performed to study the morphology of interstitial cells of Cajal (ICCs). Stem cell factor (SCF) expression and c-kit phosphorylation were determined by Western blot analysis, and the mRNA levels of inducible NO synthase (iNOS) were determined by RT-PCR. Nitric oxide (NO) content, superoxide dismutase (SOD) activity, and malondialdehyde (MDA) concentration were detected using commercial kits. Intestinal transit and muscular contractility were significantly lower in the LPS-treated group than in the control group. Immunocytochemical experiments showed that the total number of ICCs, and the total and average lengths of the ICC processes were significantly decreased in the LPS-treated group compared with those in the control group. In LPS-treated animals, magnolol pretreatment significantly accelerated intestinal transit, increased circular muscle contraction, and prevented ICC morphology changes. Phosphorylation of c-kit and expression of SCF were significantly downregulated in LPS-treated animals compared with control animals. Magnolol pretreatment prevented sepsis-induced decreases in c-kit phosphorylation and SCF expression in LPS-treated animals. Magnolol pretreatment prevented the sepsis-induced increase in NO concentration, iNOS expression, and MDA concentration, and decrease in SOD activity in LPS-treated animals. Our results suggest that magnolol treatment prevents sepsis-induced intestinal dysmotility by regulating SCF/c-kit and NO signaling to maintain functional ICCs.
Alain, S; Lachaise, V; Hantz, S; Denis, F
2010-04-01
The broad use of cytomegalovirus (CMV) viral load quantification in blood to follow immunosuppressed patients need standardized assays. Choice of whole blood allows follow-up for several viruses and simplifies pretreatment and storage of samples. We therefore evaluated the LightCycler CMV Quant Kit (Roche Diagnostics) assay on whole blood after a manual extraction (High Pure viral nucleic acid kit, Roche Diagnostics), using as a reference an in-house Taqman assay (LC1UL83) which has been validated in various clinical situations. A panel obtained by serial dilutions of a virion stock in CMV whole blood, a commercial plasma quality control (VQC, Argène, France) crude or diluted in whole blood, infected cells extracts and 46 clinical samples from transplanted patients were tested simultaneously by both techniques. For plasma quality controls, both PCR assays are correlated VQC (R(2)=0.93). On whole blood or infected cells dilutions, correlation shows an overestimation by the LC1UL83 assay (mean 1.2 log copies/ml) over 3 log though R(2)=0.94. Results with CMV Quant Kit are closer to expected values. Results on clinical samples are close to quality controls with a lower variation of quantification (0.76 log copies/ml). CMV Quant Kit performs well when compared with a clinically validated PCR. Quality control results showed discrepancies between plasma and whole blood, demonstrating the need for whole blood standardized panels to compare the methods. This underlines the need to follow a patient with the same technique during his follow-up. Copyright 2009 Elsevier Masson SAS. All rights reserved.
Kitchener, H; Gittins, M; Cruickshank, M; Moseley, C; Fletcher, S; Albrow, R; Gray, A; Brabin, L; Torgerson, D; Crosbie, E J; Sargent, A; Roberts, C
2018-06-01
Objectives To measure the feasibility and effectiveness of interventions to increase cervical screening uptake amongst young women. Methods A two-phase cluster randomized trial conducted in general practices in the NHS Cervical Screening Programme. In Phase 1, women in practices randomized to intervention due for their first invitation to cervical screening received a pre-invitation leaflet and, separately, access to online booking. In Phase 2, non-attenders at six months were randomized to one of: vaginal self-sample kits sent unrequested or offered; timed appointments; nurse navigator; or the choice between nurse navigator or self-sample kits. Primary outcome was uplift in intervention vs. control practices, at 3 and 12 months post invitation. Results Phase 1 randomized 20,879 women. Neither pre-invitation leaflet nor online booking increased screening uptake by three months (18.8% pre-invitation leaflet vs. 19.2% control and 17.8% online booking vs. 17.2% control). Uptake was higher amongst human papillomavirus vaccinees at three months (OR 2.07, 95% CI 1.69-2.53, p < 0.001). Phase 2 randomized 10,126 non-attenders, with 32-34 clusters for each intervention and 100 clusters as controls. Sending self-sample kits increased uptake at 12 months (OR 1.51, 95% CI 1.20-1.91, p = 0.001), as did timed appointments (OR 1.41, 95% CI 1.14-1.74, p = 0.001). The offer of a nurse navigator, a self-sample kits on request, and choice between timed appointments and nurse navigator were ineffective. Conclusions Amongst non-attenders, self-sample kits sent and timed appointments achieved an uplift in screening over the short term; longer term impact is less certain. Prior human papillomavirus vaccination was associated with increased screening uptake.
Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data.
Barre, Arnaud; Armand, Stéphane
2014-04-01
C3D file format is widely used in the biomechanical field by companies and laboratories to store motion capture systems data. However, few software packages can visualize and modify the integrality of the data in the C3D file. Our objective was to develop an open-source and multi-platform framework to read, write, modify and visualize data from any motion analysis systems using standard (C3D) and proprietary file formats (used by many companies producing motion capture systems). The Biomechanical ToolKit (BTK) was developed to provide cost-effective and efficient tools for the biomechanical community to easily deal with motion analysis data. A large panel of operations is available to read, modify and process data through C++ API, bindings for high-level languages (Matlab, Octave, and Python), and standalone application (Mokka). All these tools are open-source and cross-platform and run on all major operating systems (Windows, Linux, MacOS X). Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Nagata, H; Worobec, A S; Oh, C K; Chowdhury, B A; Tannenbaum, S; Suzuki, Y; Metcalfe, D D
1995-01-01
Both stem cells and mast cells express c-kit and proliferate after exposure to c-kit ligand. Mutations in c-kit may enhance or interfere with the ability of c-kit receptor to initiate the intracellular pathways resulting in cell proliferation. These observations suggested to us that mastocytosis might in some patients result from mutations in c-kit. cDNA synthesized from peripheral blood mononuclear cells of patients with indolent mastocytosis, mastocytosis with an associated hematologic disorder, aggressive mastocytosis, solitary mastocytoma, and chronic myelomonocytic leukemia unassociated with mastocytosis was thus screened for a mutation of c-kit. This analysis revealed that four of four mastocytosis patients with an associated hematologic disorder with predominantly myelodysplastic features had an A-->T substitution at nt 2468 of c-kit mRNA that causes an Asp-816-->Val substitution. One of one patient examined who had mastocytosis with an associated hematologic disorder had the corresponding mutation in genomic DNA. Identical or similar amino acid substitutions in mast cell lines result in ligand-independent autophosphorylation of the c-kit receptor. This mutation was not identified in the patients within the other disease categories or in 67 of 67 controls. The identification of the point mutation Asp816Val in c-kit in patients with mastocytosis with an associated hematologic disorder provides insight not only into the pathogenesis of this form of mastocytosis but also into how hematopoiesis may become dysregulated and may serve to provide a means of confirming the diagnosis, assessing prognosis, and developing intervention strategies. Images Fig. 1 Fig. 2 Fig. 3 PMID:7479840
Nagata, H; Worobec, A S; Oh, C K; Chowdhury, B A; Tannenbaum, S; Suzuki, Y; Metcalfe, D D
1995-11-07
Both stem cells and mast cells express c-kit and proliferate after exposure to c-kit ligand. Mutations in c-kit may enhance or interfere with the ability of c-kit receptor to initiate the intracellular pathways resulting in cell proliferation. These observations suggested to us that mastocytosis might in some patients result from mutations in c-kit. cDNA synthesized from peripheral blood mononuclear cells of patients with indolent mastocytosis, mastocytosis with an associated hematologic disorder, aggressive mastocytosis, solitary mastocytoma, and chronic myelomonocytic leukemia unassociated with mastocytosis was thus screened for a mutation of c-kit. This analysis revealed that four of four mastocytosis patients with an associated hematologic disorder with predominantly myelodysplastic features had an A-->T substitution at nt 2468 of c-kit mRNA that causes an Asp-816-->Val substitution. One of one patient examined who had mastocytosis with an associated hematologic disorder had the corresponding mutation in genomic DNA. Identical or similar amino acid substitutions in mast cell lines result in ligand-independent autophosphorylation of the c-kit receptor. This mutation was not identified in the patients within the other disease categories or in 67 of 67 controls. The identification of the point mutation Asp816Val in c-kit in patients with mastocytosis with an associated hematologic disorder provides insight not only into the pathogenesis of this form of mastocytosis but also into how hematopoiesis may become dysregulated and may serve to provide a means of confirming the diagnosis, assessing prognosis, and developing intervention strategies.
Kaminski, Alexander; Ma, Nan; Donndorf, Peter; Lindenblatt, Nicole; Feldmeier, Gregor; Ong, Lee-Lee; Furlani, Dario; Skrabal, Christian A; Liebold, Andreas; Vollmar, Brigitte; Steinhoff, Gustav
2008-01-01
In the era of intravascular approaches for regenerative cell therapy, the underlying mechanisms of stem cell migration to non-marrow tissue have not been clarified. We hypothesized that next to a local inflammatory response implying adhesion molecule expression, endothelial nitric oxide synthase (eNOS)-dependent signaling is required for stromal- cell-derived factor-1 alpha (SDF-1alpha)-induced adhesion of c-kit+ cells to the vascular endothelium. SDF-1alpha/tumor necrosis factor-alpha (TNF-alpha)-induced c-kit+-cell shape change and migration capacity was studied in vitro using immunohistochemistry and Boyden chamber assays. In vivo interaction of c-kit+ cells from bone marrow with the endothelium in response to SDF-1alpha/TNF-alpha stimulation was visualized in the cremaster muscle microcirculation of wild-type (WT) and eNOS (-/-) mice using intravital fluorescence microscopy. In addition, NOS activity was inhibited with N-nitro-L-arginine-methylester-hydrochloride in WT mice. To reveal c-kit+-specific adhesion behavior, endogenous leukocytes (EL) and c-kit+ cells from peripheral blood served as control. Moreover, intercellular adhesion molecule-1 (ICAM-1) and CXCR4 were blocked systemically to determine their role in inflammation-related c-kit+-cell adhesion. In vitro, SDF-1alpha enhanced c-kit+-cell migration. In vivo, SDF-1alpha alone triggered endothelial rolling-not firm adherence-of c-kit+ cells in WT mice. While TNF-alpha alone had little effect on adhesion of c-kit+ cells, it induced maximum endothelial EL adherence. However, after combined treatment with SDF-1alpha+TNF-alpha, endothelial adhesion of c-kit+ cells increased independent of their origin, while EL adhesion was not further incremented. Systemic treatment with anti-ICAM-1 and anti-CXCR4-monoclonal antibody completely abolished endothelial c-kit+-cell adhesion. In N-nitro-L-arginine-methylester-hydrochloride-treated WT mice as well as in eNOS (-/-) mice, firm endothelial adhesion of c-kit+ cells was entirely abrogated, while EL adhesion was significantly increased. The chemokine SDF-1alpha mediates firm adhesion c-kit+ cells only in the presence of TNF-alpha stimulation via an ICAM-1- and CXCR4-dependent mechanism. The presence of eNOS appears to be a crucial and specific factor for firm c-kit+-cell adhesion to the vascular endothelium.
2010-01-01
Research in plant molecular biology involves DNA purification on a daily basis. Although different commercial kits enable convenient extraction of high-quality DNA from E. coli cells, PCR and agarose gel samples as well as plant tissues, each kit is designed for a particular type of DNA extraction work, and the cost of purchasing these kits over a long run can be considerable. Furthermore, a simple method for the isolation of binary plasmid from Agrobacterium tumefaciens cells with satisfactory yield is lacking. Here we describe an easy protocol using homemade silicon dioxide matrix and seven simple solutions for DNA extraction from E. coli and A. tumefaciens cells, PCR and restriction digests, agarose gel slices, and plant tissues. Compared with the commercial kits, this protocol allows rapid DNA purification from diverse sources with comparable yield and purity at negligible cost. Following this protocol, we have demonstrated: (1) DNA fragments as small as a MYC-epitope tag coding sequence can be successfully recovered from an agarose gel slice; (2) Miniprep DNA from E. coli can be eluted with as little as 5 μl water, leading to high DNA concentrations (>1 μg/μl) for efficient biolistic bombardment of Arabidopsis seedlings, polyethylene glycol (PEG)-mediated Arabidopsis protoplast transfection and maize protoplast electroporation; (3) Binary plasmid DNA prepared from A. tumefaciens is suitable for verification by restriction analysis without the need for large scale propagation; (4) High-quality genomic DNA is readily isolated from several plant species including Arabidopsis, tobacco and maize. Thus, the silicon dioxide matrix-based DNA purification protocol offers an easy, efficient and economical way to extract DNA for various purposes in plant research. PMID:20180960
Murayama, Asako; Sugiyama, Nao; Watashi, Koichi; Masaki, Takahiro; Suzuki, Ryosuke; Aizaki, Hideki; Mizuochi, Toshiaki; Wakita, Takaji
2012-01-01
An accurate and reliable quantitative assay for hepatitis C virus (HCV) is essential for measuring viral propagation and the efficacy of antiviral therapy. There is a growing need for domestic reference panels for evaluation of clinical assay kits because the performance of these kits may vary with region-specific genotypes or polymorphisms. In this study, we established a reference panel by selecting 80 donated blood specimens in Japan that tested positive for HCV. Using this panel, we quantified HCV viral loads using two HCV RNA kits and five core antigen (Ag) kits currently available in Japan. The data from the two HCV RNA assay kits showed excellent correlation. All RNA titers were distributed evenly across a range from 3 to 7 log IU/ml. Although the data from the five core Ag kits also correlated with RNA titers, the sensitivities of individual kits were not sufficient to quantify viral load in all samples. As calculated by the correlation with RNA titers, the theoretical lower limits of detection by these core Ag assays were higher than those for the detection of RNA. Moreover, in several samples in our panel, core Ag levels were underestimated compared to RNA titers. Sequence analysis in the HCV core region suggested that polymorphisms at amino acids 47 to 49 of the core Ag were responsible for this underestimation. The panel established in this study will be useful for estimating the quality of currently available and upcoming HCV assay kits; such quality control is essential for clinical usage of these kits. PMID:22495557
Moura, David S; Ramos, Rafael; Fernandez-Serra, Antonio; Serrano, Teresa; Cruz, Julia; Alvarez-Alegret, Ramiro; Ortiz-Duran, Rosa; Vicioso, Luis; Gomez-Dorronsoro, Maria Luisa; Garcia Del Muro, Xavier; Martinez-Trufero, Javier; Rubio-Casadevall, Jordi; Sevilla, Isabel; Lainez, Nuria; Gutierrez, Antonio; Serrano, Cesar; Lopez-Alvarez, Maria; Hindi, Nadia; Taron, Miguel; López-Guerrero, José Antonio; Martin-Broto, Javier
2018-04-03
There are limited findings available on KIT-negative GIST-like (KNGL) population. Also, KIT expression may be post-transcriptionally regulated by miRNA221 and miRNA222. Hence, the aim of this study is to characterize KNGL population, by differential gene expression, and to analyze miRNA221/222 expression and their prognostic value in KNGL patients. KIT , PDGFRA , DOG1 , IGF1R , MIR221 and MIR222 expression levels were determined by qRT-PCR. We also analyzed KIT and PDGFRA mutations, DOG1 expression, by immunohistochemistry, along with clinical and pathological data. Disease-free survival (DFS) and overall survival (OS) differences were calculated using Log-rank test. Hierarchical cluster analyses from gene expression data identified two groups: group I had KIT , DOG1 and PDGFRA overexpression and IGF1R underexpression and group II had overexpression of IGF1R and low expression of KIT , DOG1 and PDGFRA . Group II had a significant worse OS ( p = 0.013) in all the series, and showed a tendency for worse OS ( p = 0.11), when analyzed only the localized cases. MiRNA222 expression was significantly lower in a control subset of KIT-positive GIST ( p < 0.001). OS was significantly worse in KNGL cases with higher expression of MIR221 ( p = 0.028) or MIR222 ( p = 0.014). We identified two distinct KNGL subsets, with a different prognostic value. Increased levels of miRNA221/222, which are associated with worse OS, could explain the absence of KIT protein expression of most KNGL tumors.
Delyon, Julie; Chevret, Sylvie; Jouary, Thomas; Dalac, Sophie; Dalle, Stephane; Guillot, Bernard; Arnault, Jean-Philippe; Avril, Marie-Françoise; Bedane, Christophe; Bens, Guido; Pham-Ledard, Anne; Mansard, Sandrine; Grange, Florent; Machet, Laurent; Meyer, Nicolas; Legoupil, Delphine; Saiag, Philippe; Idir, Zakia; Renault, Victor; Deleuze, Jean-François; Hindie, Elif; Battistella, Maxime; Dumaz, Nicolas; Mourah, Samia; Lebbe, Celeste
2018-01-01
Mutated oncogenic KIT is a therapeutic target in melanoma. We conducted a multicenter phase II trial on the KIT inhibitor nilotinib in patients with unresectable melanoma harboring KIT alteration. The primary endpoint was the response rate (complete response or partial response following Response Evaluation Criteria in Solid Tumors criteria) at 6 months. Pharmacodynamic studies using KIT sequencing, qPCR array, and immunostaining of downstream KIT effectors were performed during treatment. Twenty-five patients were included and received 400 mg oral nilotinib twice daily. At 6 months, nilotinib induced tumor response in four patients. The best overall response rate was 20% and the disease control rate was 56%, limited to patients harboring exon 11 or 13 mutations. Four patients exhibited durable response, including three persisting (3.6 and 2.8 years for two patients with stage IIIC and 2.5 years for one with IVM1b melanoma). A reduction in signal transducer and activator of transcription (STAT) 3 phosphorylation and its effectors (BCL-2, MCL-1) in tumors during follow-up was significantly associated with clinical response. In the KIT-mutated melanoma cell line M230, nilotinib reduced STAT3 signaling and STAT inhibitors were as efficient as KIT inhibitors in reducing cell proliferation. Our study evidences a significant association between STAT3 inhibition and response to nilotinib, and provides a rationale for future research assessing STAT inhibitors in KIT-mutated melanoma. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Zhu, Bo; Li, Lan-ying; Lü, Guo-yi; Xue, Yu-liang; Ye, Tie-hu
2010-04-01
To explore the effects of naloxone on the expression of c-kit receptor (c-kit R) and its ligand stem cell factor (SCF) in human embryo neuronal hypoxic injury. Serum-free cerebral cortical cultures prepared from embryonic human brains were deprived of both oxygen and glucose which would set up an environment more likely with that of in vivo ischemic injury. Neurons in 24-well culture plates were randomly divided into four groups: control group, hypoxia group, naloxone 0.5 microg/ml group and naloxone 10 microg/ml group. MTT assay and biological analysis were performed to study the cell death and the changes of extracellular concentrations of lactate dehydrogenase (LDH) after combined oxygen-glucose deprivation. Neurons in 25 ml culture flasks were also randomly allocated into four groups as previously described. Intracellular total RNA were extracted at different time points: pre-hypoxia, immediately after hypoxia, and 3, 6, 12, and 24 hours after reoxygenation. The changes of SCF/c-kit R mRNA expression in hypoxic neurons treated with different concentrations of naloxone pre and post oxygen-glucose deprivation were determined with RT-PCR. The cell vitality detected by MTT assay decreased significantly in hypoxia group and naloxone 0.5 microg/ml group when compared with control group (P<0.01), while no significant difference was found between naloxone 0.5 microg/ml group and hypoxia group or between naloxone 10 microg/ml group and control group. Extracellular concentration of LDH significantly increased in hypoxia group (P<0.05), while no difference was found between naloxone 0.5 microg/ml group and control group, between naloxone 0.5 microg/ml and hypoxia group, or between naloxone 10 microg/ml and control group (all P>0.05). Immediately after oxygen-glucose deprivation, the expression of SCF/c-kit R mRNA increased significantly (P<0.01). Among those the expression of SCF presented a distribution of double-peak value within 24 hours. After treated with different concentrations of naloxone, the peak value of each group were delayed to appear and went down with the increasing of naloxone concentration. The peak values in all treated groups were significantly different from that in control group (P<0.01). The expression of SCF/c-kit R mRNA increases at the early stage after combined oxygen-glucose deprivation. Naloxone 0.5 microg/ml can attenuate cell injuries and regulate the expression of SCF/c-kit R. Naloxone may protect neurons by modulating the expressions of some cytokines.
Pilot Fullerton points Hasselblad camera out forward flight deck window W6
NASA Technical Reports Server (NTRS)
1982-01-01
Pilot Fullerton, wearing communications kit assembly (ASSY) mini headset (HDST), points Hasselblad camera out forward flight deck pilots station window W6. Forward flight deck control panels F4, F8, and R1, flight mirror assy, Volume R5 Kit, and pilots ejection seat (S2) headrest appear in view.
Heidari, Banafsheh; Rahmati-Ahmadabadi, Maryam; Akhondi, Mohammad Mehdi; Zarnani, Amir Hassan; Jeddi-Tehrani, Mahmood; Shirazi, Abolfazl; Naderi, Mohammad Mehdi; Behzadi, Bahareh
2012-10-01
Presently the techniques for making transgenic animals are cumbersome, required costly instruments and trained man-power. The ability of spermatogonial stem cells (SSCs) to integrate foreign genes has provided the opportunity for developing alternate methods for generation of transgenic animals. One of the big challenges in this field is development of the methods to identify and purify donor SSCs by antibody mediated cell sorting. The present study was aimed to identify goat subpopulations of SSCs using polyclonal antibodies against PGP9.5 and c-kit molecular markers as well as the growth characteristics of SSCs during short term culture. One month old goats' testicular samples were subjected for immunohistochemical and immunocytochemical evaluations. The enzymatically isolated SSCs were cultured in DMEM plus FCS supplemented with (treatment) or without (control) growth factors (GDNF, LIF, FGF, and EGF) for 2 weeks. At the end of culture the morphological characteristics of SSCs colonies and immunocytochemical staining were evaluated. The number and size of colonies in treatment groups were significantly (P < 0.01) higher than corresponding values in controls. The presence of PGP 9.5 and c-kit antigens was confirmed in immunocytochemical evaluation. In immunocytochemical evaluation, the proportion of c-kit and PGP9.5 positive cells were significantly (P < 0.001) higher in control and treatment groups, respectively. The presence of PGP9.5 and c-kit antigens was confirmed in goat SSCs. Moreover, culture medium supplementation with growth factors could effectively retain the undifferentiation status of SSCs, reflected as a higher population of PGP9.5 positive cells, after short term culture.
The eBioKit, a stand-alone educational platform for bioinformatics.
Hernández-de-Diego, Rafael; de Villiers, Etienne P; Klingström, Tomas; Gourlé, Hadrien; Conesa, Ana; Bongcam-Rudloff, Erik
2017-09-01
Bioinformatics skills have become essential for many research areas; however, the availability of qualified researchers is usually lower than the demand and training to increase the number of able bioinformaticians is an important task for the bioinformatics community. When conducting training or hands-on tutorials, the lack of control over the analysis tools and repositories often results in undesirable situations during training, as unavailable online tools or version conflicts may delay, complicate, or even prevent the successful completion of a training event. The eBioKit is a stand-alone educational platform that hosts numerous tools and databases for bioinformatics research and allows training to take place in a controlled environment. A key advantage of the eBioKit over other existing teaching solutions is that all the required software and databases are locally installed on the system, significantly reducing the dependence on the internet. Furthermore, the architecture of the eBioKit has demonstrated itself to be an excellent balance between portability and performance, not only making the eBioKit an exceptional educational tool but also providing small research groups with a platform to incorporate bioinformatics analysis in their research. As a result, the eBioKit has formed an integral part of training and research performed by a wide variety of universities and organizations such as the Pan African Bioinformatics Network (H3ABioNet) as part of the initiative Human Heredity and Health in Africa (H3Africa), the Southern Africa Network for Biosciences (SAnBio) initiative, the Biosciences eastern and central Africa (BecA) hub, and the International Glossina Genome Initiative.
The eBioKit, a stand-alone educational platform for bioinformatics
Conesa, Ana; Bongcam-Rudloff, Erik
2017-01-01
Bioinformatics skills have become essential for many research areas; however, the availability of qualified researchers is usually lower than the demand and training to increase the number of able bioinformaticians is an important task for the bioinformatics community. When conducting training or hands-on tutorials, the lack of control over the analysis tools and repositories often results in undesirable situations during training, as unavailable online tools or version conflicts may delay, complicate, or even prevent the successful completion of a training event. The eBioKit is a stand-alone educational platform that hosts numerous tools and databases for bioinformatics research and allows training to take place in a controlled environment. A key advantage of the eBioKit over other existing teaching solutions is that all the required software and databases are locally installed on the system, significantly reducing the dependence on the internet. Furthermore, the architecture of the eBioKit has demonstrated itself to be an excellent balance between portability and performance, not only making the eBioKit an exceptional educational tool but also providing small research groups with a platform to incorporate bioinformatics analysis in their research. As a result, the eBioKit has formed an integral part of training and research performed by a wide variety of universities and organizations such as the Pan African Bioinformatics Network (H3ABioNet) as part of the initiative Human Heredity and Health in Africa (H3Africa), the Southern Africa Network for Biosciences (SAnBio) initiative, the Biosciences eastern and central Africa (BecA) hub, and the International Glossina Genome Initiative. PMID:28910280
Chen, Lei L; Zhu, Jing; Schumacher, Jonathan; Wei, Chongjuan; Ramdas, Latha; Prieto, Victor G; Jimenez, Arnie; Velasco, Marco A; Tripp, Sheryl R; Andtbacka, Robert H I; Gouw, Launce; Rodgers, George M; Zhang, Liansheng; Chan, Benjamin K; Cassidy, Pamela B; Benjamin, Robert S; Leachman, Sancy A; Frazier, Marsha L
2017-01-01
We demonstrate that SCF-KIT signaling induces synthesis and secretion of endothelin-3 (ET3) in human umbilical vein endothelial cells and melanoma cells in vitro, gastrointestinal stromal tumors, human sun-exposed skin, and myenteric plexus of human colon post-fasting in vivo. This is the first report of a physiological mechanism of ET3 induction. Integrating our finding with supporting data from literature leads us to discover a previously unreported pathway of nitric oxide (NO) generation derived from physiological endothelial NO synthase (eNOS) or neuronal NOS (nNOS) activation (referred to as the KIT-ET3-NO pathway). It involves: (1) SCF-expressing cells communicate with neighboring KIT-expressing cells directly or indirectly (cleaved soluble SCF). (2) SCF-KIT signaling induces timely local ET3 synthesis and secretion. (3) ET3 binds to ETBR on both sides of intercellular space. (4) ET3-binding-initiated-ETBR activation increases cytosolic Ca2+, activates cell-specific eNOS or nNOS. (5) Temporally- and spatially-precise NO generation. NO diffuses into neighboring cells, thus acts in both SCF- and KIT-expressing cells. (6) NO modulates diverse cell-specific functions by NO/cGMP pathway, controlling transcriptional factors, or other mechanisms. We demonstrate the critical physiological role of the KIT-ET3-NO pathway in fulfilling high demand (exceeding basal level) of endothelium-dependent NO generation for coping with atherosclerosis, pregnancy, and aging. The KIT-ET3-NO pathway most likely also play critical roles in other cell functions that involve dual requirement of SCF-KIT signaling and NO. New strategies (e.g. enhancing the KIT-ET3-NO pathway) to harness the benefit of endogenous eNOS and nNOS activation and precise NO generation for correcting pathophysiology and restoring functions warrant investigation.
Zhu, Jing; Schumacher, Jonathan; Wei, Chongjuan; Ramdas, Latha; Prieto, Victor G.; Jimenez, Arnie; Velasco, Marco A.; Tripp, Sheryl R.; Andtbacka, Robert H. I.; Gouw, Launce; Rodgers, George M.; Zhang, Liansheng; Chan, Benjamin K.; Cassidy, Pamela B.; Benjamin, Robert S.; Leachman, Sancy A.; Frazier, Marsha L.
2017-01-01
We demonstrate that SCF-KIT signaling induces synthesis and secretion of endothelin-3 (ET3) in human umbilical vein endothelial cells and melanoma cells in vitro, gastrointestinal stromal tumors, human sun-exposed skin, and myenteric plexus of human colon post-fasting in vivo. This is the first report of a physiological mechanism of ET3 induction. Integrating our finding with supporting data from literature leads us to discover a previously unreported pathway of nitric oxide (NO) generation derived from physiological endothelial NO synthase (eNOS) or neuronal NOS (nNOS) activation (referred to as the KIT-ET3-NO pathway). It involves: (1) SCF-expressing cells communicate with neighboring KIT-expressing cells directly or indirectly (cleaved soluble SCF). (2) SCF-KIT signaling induces timely local ET3 synthesis and secretion. (3) ET3 binds to ETBR on both sides of intercellular space. (4) ET3-binding-initiated-ETBR activation increases cytosolic Ca2+, activates cell-specific eNOS or nNOS. (5) Temporally- and spatially-precise NO generation. NO diffuses into neighboring cells, thus acts in both SCF- and KIT-expressing cells. (6) NO modulates diverse cell-specific functions by NO/cGMP pathway, controlling transcriptional factors, or other mechanisms. We demonstrate the critical physiological role of the KIT-ET3-NO pathway in fulfilling high demand (exceeding basal level) of endothelium-dependent NO generation for coping with atherosclerosis, pregnancy, and aging. The KIT-ET3-NO pathway most likely also play critical roles in other cell functions that involve dual requirement of SCF-KIT signaling and NO. New strategies (e.g. enhancing the KIT-ET3-NO pathway) to harness the benefit of endogenous eNOS and nNOS activation and precise NO generation for correcting pathophysiology and restoring functions warrant investigation. PMID:28880927
Petti, Filippo; Thelemann, April; Kahler, Jen; McCormack, Siobhan; Castaldo, Linda; Hunt, Tony; Nuwaysir, Lydia; Zeiske, Lynn; Haack, Herbert; Sullivan, Laura; Garton, Andrew; Haley, John D
2005-08-01
OSI-930, a potent thiophene inhibitor of the Kit, KDR, and platelet-derived growth factor receptor tyrosine kinases, was used to selectively inhibit tyrosine phosphorylation downstream of juxtamembrane mutant Kit in the mast cell leukemia line HMC-1. Inhibition of Kit kinase activity resulted in a rapid dephosphorylation of Kit and inhibition of the downstream signaling pathways. Attenuation of Ras-Raf-Erk (phospho-Erk, phospho-p38), phosphatidyl inositol-3' kinase (phospho-p85, phospho-Akt, phospho-S6), and signal transducers and activators of transcription signaling pathways (phospho-STAT3/5/6) were measured by affinity liquid chromatography tandem mass spectrometry, by immunoblot, and by tissue microarrays of fixed cell pellets. To more globally define additional components of Kit signaling temporally altered by kinase inhibition, a novel multiplex quantitative isobaric peptide labeling approach was used. This approach allowed clustering of proteins by temporal expression patterns. Kit kinase, which dephosphorylates rapidly upon kinase inhibition, was shown to regulate both Shp-1 and BDP-1 tyrosine phosphatases and the phosphatase-interacting protein PSTPIP2. Interactions with SH2 domain adapters [growth factor receptor binding protein 2 (Grb2), Cbl, Slp-76] and SH3 domain adapters (HS1, cortactin, CD2BP3) were attenuated by inhibition of Kit kinase activity. Functional crosstalk between Kit and the non-receptor tyrosine kinases Fes/Fps, Fer, Btk, and Syk was observed. Inhibition of Kit modulated phosphorylation-dependent interactions with pathways controlling focal adhesion (paxillin, leupaxin, p130CAS, FAK1, the Src family kinase Lyn, Wasp, Fhl-3, G25K, Ack-1, Nap1, SH3P12/ponsin) and septin-actin complexes (NEDD5, cdc11, actin). The combined use of isobaric protein quantitation and expression clustering, immunoblot, and tissue microarray strategies allowed temporal measurement signaling pathways modulated by mutant Kit inhibition in a model of mast cell leukemia.
1998-10-01
Stay Breast Cancer Surgery Self -Test Kit: Rapid Diagnosis of Urogenital Infections in Military Women PRINCIPAL INVESTIGATOR: Gwen K. Wyatt, R.N...the home and phone contacts) consisting of individual physical and psychological support, self -care, and education; and the control group, who receive...intervention and control group perceptions on the dimensions of physical functioning, anxiety status, quality of life, and self -care knowledge. C. Compare the
TGF-Beta Antibody for Prostate Cancer: Role of ERK
2011-07-01
St. Louis, MO). rotein concentration was assayed and adjusted to 1 mg/mL ith the lysis/wash buffer. An aliquot of 600 L of cell lysates as precleared...kit. Precleared lysate was immunoprecip- ated by the crosslinked antibody and agarose mixture for over- ight on 4°C. Control agarose resin in the kit...was used as a egative control when western-blot analysis was conducted. estern Blot Analysis ell lysates were prepared by using cell lysis buffer
Opportunistic data locality for end user data analysis
NASA Astrophysics Data System (ADS)
Fischer, M.; Heidecker, C.; Kuehn, E.; Quast, G.; Giffels, M.; Schnepf, M.; Heiss, A.; Petzold, A.
2017-10-01
With the increasing data volume of LHC Run2, user analyses are evolving towards increasing data throughput. This evolution translates to higher requirements for efficiency and scalability of the underlying analysis infrastructure. We approach this issue with a new middleware to optimise data access: a layer of coordinated caches transparently provides data locality for high-throughput analyses. We demonstrated the feasibility of this approach with a prototype used for analyses of the CMS working groups at KIT. In this paper, we present our experience both with the approach in general, and our prototype in specific.
Experimental investigation of a supersonic micro turbine running with hexamethyldisiloxane
NASA Astrophysics Data System (ADS)
Weiß Andreas, P.; Josef, Hauer; Tobias, Popp; Markus, Preißinger
2017-09-01
Experimentally determined efficiency characteristics of a supersonic micro turbine are discussed in the present paper. The micro turbine is a representative of a "micro-turbine-generator-construction-kit" for ORC small scale waste heat recovery. The isentropic total-to-static efficiency of the 12 kW turbine reaches an excellent design point performance of 73.4 %. Furthermore, its off-design operating behavior is very advantageous for small waste heat recovery plants: the turbine efficiency keeps a high level over a wide range of pressure ratio and rotational speed.
Imatinib mesylate inhibits Leydig cell tumor growth: evidence for in vitro and in vivo activity.
Basciani, Sabrina; Brama, Marina; Mariani, Stefania; De Luca, Gabriele; Arizzi, Mario; Vesci, Loredana; Pisano, Claudio; Dolci, Susanna; Spera, Giovanni; Gnessi, Lucio
2005-03-01
Leydig cell tumors are usually benign tumors of the male gonad. However, if the tumor is malignant, no effective treatments are currently available. Leydig cell tumors express platelet-derived growth factor (PDGF), kit ligand and their respective receptors, PDGFR and c-kit. We therefore evaluated the effects of imatinib mesylate (imatinib), a selective inhibitor of the c-kit and PDGFR tyrosine kinases, on the growth of rodent Leydig tumor cell lines in vivo and in vitro, and examined, in human Leydig cell tumor samples, the expression of activated PDGFR and c-kit and the mutations in exons of the c-kit gene commonly associated with solid tumors. Imatinib caused concentration-dependent decreases in the viability of Leydig tumor cell lines, which coincided with apoptosis and inhibition of proliferation and ligand-stimulated phosphorylation of c-kit and PDGFRs. Mice bearing s.c. allografts of a Leydig tumor cell line treated with imatinib p.o., had an almost complete inhibition of tumor growth, less tumor cell proliferation, increased apoptosis, and a lesser amount of tumor-associated mean vessel density compared with controls. No drug-resistant tumors appeared during imatinib treatment but tumors regrew after drug withdrawal. Human Leydig cell tumors showed an intense expression of the phosphorylated form of c-kit and a less intense expression of phosphorylated PDGFRs. No activating mutations in common regions of mutation of the c-kit gene were found. Our studies suggest that Leydig cell tumors might be a potential target for imatinib therapy.
Peng, Yunping; Wu, Junlin; Wang, Jihua; Li, Wenmei; Yu, Shujuan
2012-04-01
Malaria has been recognized as a human disease for thousands of years and remains one of the most common diseases affecting humans worldwide. Therefore, a method for rapidly detecting Plasmodium falciparum is necessary and useful. We have developed Wondfo rapid diagnostic kit based on nano-gold immunochromatography assay for the detection of P. falciparum in patient specimen. In the present study, we demonstrated the sensitivity and specificity of the rapid diagnostic kit in which nano-gold labeling techniques and the monoclonal antibodies against histidine-rich protein-2 of P. falciparum were used to establish two-antibody sandwich immunochromatographic assay for detecting P. falciparum. By using microscopic examination of blood smears as control, the sensitivity, specificity, and feasibility of Wondfo rapid diagnostic kit was determined in the prompt and accurate diagnosis of malaria. In this study, 1,558 blood samples were collected from outpatient clinics in China and detected by both Wondfo kit and microscopic examination. The Wondfo kit did not show cross-reaction with microfilaria, Toxoplasma gondii, and other parasites in the blood. The patient samples positive for rheumatoid factor, HIV, tuberculosis, and syphilis did not show false positivity when testing with Wondfo kit. The detection sensitivity and specificity of Wondfo rapid diagnostic kit were 95.49% and 99.53%, respectively. These results indicate that our rapid diagnostic assay may be useful for detecting P. falciparum in patient specimen.
Regulation of a mammalian gene bearing a CpG island promoter and a distal enhancer.
Berrozpe, Georgina; Bryant, Gene O; Warpinski, Katherine; Ptashne, Mark
2013-08-15
A quantitative nucleosome occupancy assay revealed rules for nucleosome disposition in yeast and showed how disposition affects regulation of the GAL genes. Here, we show how those findings apply to the control of Kit, a mammalian gene. The Kit promoter lies in a CpG island, and its enhancer (active in mast cells) lies some 150 kb upstream. Nucleosomes form with especially high avidities at the Kit promoter, a reaction that, we surmise, ensures extremely low basal expression. In mast cells, transcriptional activators displace nucleosomes that are less tightly formed at the Kit enhancer. In turn, the active enhancer replaces a single Kit promoter nucleosome with the transcriptional machinery, thereby inducing transcription over 1,000-fold. As at the yeast GAL genes, the inhibitory effects of nucleosomes facilitate high factors of induction by mammalian activators working in the absence of specific repressors. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Phase 1 Development Report for the SESSA Toolkit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Knowlton, Robert G.; Melton, Brad J; Anderson, Robert J.
The Site Exploitation System for Situational Awareness ( SESSA ) tool kit , developed by Sandia National Laboratories (SNL) , is a comprehensive de cision support system for crime scene data acquisition and Sensitive Site Exploitation (SSE). SESSA is an outgrowth of another SNL developed decision support system , the Building R estoration Operations Optimization Model (BROOM), a hardware/software solution for data acquisition, data management, and data analysis. SESSA was designed to meet forensic crime scene needs as defined by the DoD's Military Criminal Investigation Organiza tion (MCIO) . SESSA is a very comprehensive toolki t with a considerable amountmore » of database information managed through a Microsoft SQL (Structured Query Language) database engine, a Geographical Information System (GIS) engine that provides comprehensive m apping capabilities, as well as a an intuitive Graphical User Interface (GUI) . An electronic sketch pad module is included. The system also has the ability to efficiently generate necessary forms for forensic crime scene investigations (e.g., evidence submittal, laboratory requests, and scene notes). SESSA allows the user to capture photos on site, and can read and generate ba rcode labels that limit transcription errors. SESSA runs on PC computers running Windows 7, but is optimized for touch - screen tablet computers running Windows for ease of use at crime scenes and on SSE deployments. A prototype system for 3 - dimensional (3 D) mapping and measur e ments was also developed to complement the SESSA software. The mapping system employs a visual/ depth sensor that captures data to create 3D visualizations of an interior space and to make distance measurements with centimeter - level a ccuracy. Output of this 3D Model Builder module provides a virtual 3D %22walk - through%22 of a crime scene. The 3D mapping system is much less expensive and easier to use than competitive systems. This document covers the basic installation and operation of th e SESSA tool kit in order to give the user enough information to start using the tool kit . SESSA is currently a prototype system and this documentation covers the initial release of the tool kit . Funding for SESSA was provided by the Department of Defense (D oD), Assistant Secretary of Defense for Research and Engineering (ASD(R&E)) Rapid Fielding (RF) organization. The project was managed by the Defense Forensic Science Center (DFSC) , formerly known as the U.S. Army Criminal Investigation Laboratory (USACIL) . ACKNOWLEDGEMENTS The authors wish to acknowledge the funding support for the development of the Site Exploitation System for Situational Awareness (SESSA) toolkit from the Department of Defense (DoD), Assistant Secretary of Defense for Research and Engineering (ASD(R&E)) Rapid Fielding (RF) organization. The project was managed by the Defense Forensic Science Center (DFSC) , formerly known as the U.S. Army Criminal Investigation Laboratory (USACIL). Special thanks to Mr. Garold Warner, of DFSC, who served as the Project Manager. Individuals that worked on the design, functional attributes, algorithm development, system arc hitecture, and software programming include: Robert Knowlton, Brad Melton, Robert Anderson, and Wendy Amai.« less
NASA Technical Reports Server (NTRS)
Schneider, Michelle; Lippincott, Jeff; Chubb, Steve; Whitaker, Jimmy; Rice, Jim; Gillis, Robert; Sims, Chris; Sellers, Donna; Bailey, Darrell (Technical Monitor)
2002-01-01
The Telescience Resource Kit (TReK) is a PC based ground control system. It can be used by a single individual or in a group environment to monitor and control spacecraft systems and payloads. Capabilities include data receipt, data processing, data storage, data management, and data transmission. Commercial-Off-The-Shelf (COTS) hardware and software have been employed to reduce development costs, operations and maintenance costs, and to effectively take advantage of new commercial products as they become available. The TReK system is currently being used to monitor and control payloads aboard the International Space Station. It is located at sites around the world.
Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu
2011-01-01
The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.
Personal Choices, Personal Power. Career Survival Kit for Teen Education and Employment.
ERIC Educational Resources Information Center
Lindner, A. Frances
This workbook is one component of the Career Survival Kit prepared for teenage parents in Wisconsin. The workbook is designed to help teen parents identify their choices in preventing another pregnancy. It presents some thoughts about sexual decisions and responsibility. Birth control methods are described to help teens decide the best method for…
Second Step: A Violence-Prevention Curriculum. Preschool-Kindergarten (Ages 4-6). Teacher's Guide.
ERIC Educational Resources Information Center
Committee for Children, Seattle, WA.
"Second Step" for preschoolers and kindergartners is a curriculum kit designed to reduce impulsive and aggressive behavior in young children and to increase their levels of social competence by teaching skills in empathy, impulse control, and anger management. The kit, which is part of a series that includes curricula for grades 1-3,…
NASA Astrophysics Data System (ADS)
Li, Lu; Zhou, Pin; Zhang, Hongbo; Meng, Xianglong; Li, Juexiu; Sun, Tonghua
2017-06-01
Rare earth oxides (RE = Ce, La, Sm and Gd) doped ZnO supported on KIT-6 sorbents (RE-ZnO/KIT-6) were synthesized by sol-gel method and their performance for deep removal of H2S (bellow 0.1 ppmv) from gas stream at medium temperature was tested. The RE dopants (except Ce) significantly enhance the deep desulfurization capacity of ZnO/KIT-6 sorbent and maintained higher sulfur uptake capacities upon multiple cycles of regeneration by a simple thermal oxidation in 10 v% of O2 in N2 atmosphere. The results of SAXS, XRD, N2 physisorption, TEM, FIIR, and XPS implied that the KIT-6 structure of loading metal oxides remained intact. It was found that RE could hinder the ZnO crystal ripening during calcination resulted in smaller ZnO particles, enhance the interaction of ZnO and silica matrix to improve the dispersion of active phase on KIT-6. Furthermore, by increasing the outlayer electron density of Zn atom and oxygen transfer ability, the synergistic effect considered to be favorable for RE-ZnO/KIT-6 sulfidation. Even though the performance of improving ZnO dispersion was weaker than that of Sm and Gd, La-ZnO/KIT-6 performs the best deep desulfurizers by changing the surface chemical atmosphere for ZnO. Steam in the gas stream inhibited the capture of H2S by ZnO in the sorbents, in the case of La-ZnO/KIT-6, the steam content should control as lower as 5 v% to ensure the desulfurization efficiency and precision.
A Frameshift Mutation in KIT is Associated with White Spotting in the Arabian Camel
Holl, Heather; Isaza, Ramiro; Mohamoud, Yasmin; Ahmed, Ayeda; Almathen, Faisal; Youcef, Cherifi; Gaouar, Semir; Antczak, Douglas F.; Brooks, Samantha
2017-01-01
While the typical Arabian camel is characterized by a single colored coat, there are rare populations with white spotting patterns. White spotting coat patterns are found in virtually all domesticated species, but are rare in wild species. Theories suggest that white spotting is linked to the domestication process, and is occasionally associated with health disorders. Though mutations have been found in a diverse array of species, fewer than 30 genes have been associated with spotting patterns, thus providing a key set of candidate genes for the Arabian camel. We obtained 26 spotted camels and 24 solid controls for candidate gene analysis. One spotted and eight solid camels were whole genome sequenced as part of a separate project. The spotted camel was heterozygous for a frameshift deletion in KIT (c.1842delG, named KITW1 for White spotting 1), whereas all other camels were wild-type (KIT+/KIT+). No additional mutations unique to the spotted camel were detected in the EDNRB, EDN3, SOX10, KITLG, PDGFRA, MITF, and PAX3 candidate white spotting genes. Sanger sequencing of the study population identified an additional five KITW1/KIT+ spotted camels. The frameshift results in a premature stop codon five amino acids downstream, thus terminating KIT at the tyrosine kinase domain. An additional 13 spotted camels tested KIT+/KIT+, but due to phenotypic differences when compared to the KITW1/KIT+ camels, they likely represent an independent mutation. Our study suggests that there are at least two causes of white spotting in the Arabian camel, the newly described KITW1 allele and an uncharacterized mutation. PMID:28282952
Potter, Michael B.; Phengrasamy, La; Hudes, Esther S.; McPhee, Stephen J.; Walsh, Judith M.E.
2009-01-01
PURPOSE We wanted to determine whether providing home fecal occult blood test (FOBT) kits to eligible patients during influenza inoculation (flu shot) clinics can contribute to higher colorectal cancer screening (CRCS) rates. METHODS The study was time randomized. On 8 dates of an annual flu shot clinic at the San Francisco General Hospital, patients were offered flu shots as usual (control group) and on 9 other dates, patients were offered both flu shots and FOBT kits (intervention group). RESULTS The study included 514 patients aged 50 to 79 years, with 246 in the control group and 268 in the intervention group. At the conclusion of flu season, FOBT screening rates increased by 4.4 percentage points from 52.9% at baseline to 57.3% (P = .07) in the control group, and increased by 29.8 percentage points from 54.5% to 84.3% (P <.001) in the intervention group, with the change among intervention participants 25.4 percentage points greater than among control participants (P value for change difference <.001). Among patients initially due for CRCS, 20.7% in the control group and 68.0% in the intervention group were up-to-date at the conclusion of the study (P <.001). In multivariate analyses, the odds ratio for becoming up-to-date with screening in the intervention group (vs the control group) was 11.3 (95% CI, 5.8–22.0). CONCLUSIONS Offering FOBT kits during flu shot clinics dramatically increased the CRCS rate for flu shot clinic attendees. Pairing home FOBT kits with annual flu shots may be a useful strategy to improve CRCS rates in other primary care or public health settings. PMID:19139445
LAMP kit for diagnosis of non-falciparum malaria in Plasmodium ovale infected patients.
Cuadros, Juan; Martin Ramírez, Alexandra; González, Iveth J; Ding, Xavier C; Perez Tanoira, Ramon; Rojo-Marcos, Gerardo; Gómez-Herruz, Peña; Rubio, Jose Miguel
2017-01-07
Microscopy and rapid diagnosis tests have a limited sensitivity in diagnosis of malaria by Plasmodium ovale. The LAMP kit (LoopAMP®) can be used in the field without special equipment and could have an important role in malaria control programmes in endemic areas and for malaria diagnosis in returned travellers. The performance of the Pan primer of the kit in detecting malaria by P. ovale was compared with the results of standard nPCR in samples of patients returning from P. ovale endemic areas. Plasmodium ovale positive samples (29, tested by PCR and/or microscopy) and malaria negative specimens (398, tested by microscopy and PCR) were collected in different hospitals of Europe from June 2014 to March 2016 and frozen at -20 °C. Boil and spin method was used to extract DNA from all samples and amplification was performed with LoopAMP® MALARIA kit (Eiken Chemical, Japan) in an automated turbidimeter (Eiken 500). The results of LAMP read by turbidimetry and with the naked eye were compared. The kit showed a sensitivity of 100% and a specificity of 97.24% with positive and negative predictive values of 72.5 and 100%, respectively. Naked eyed readings were in accordance with turbidimetry readings (sensitivity, 92.5%, specificity, 98.96% and positive and negative predictive values, respectively, 90.24 and 99.22%). The limit of detection of LAMP assay for P. ovale was between 0.8 and 2 parasites/µl. The Pan primer of the Malaria kit LoopAMP® can detect P. ovale at very low-levels and showed a predictive negative value of 100%. This tool can be useful in malaria control and elimination programmes and in returned travellers from P. ovale endemic areas. Naked eye readings are equivalent to automated turbidimeter readings in specimens obtained with EDTA.
Dörries, Hans-Henno; Remus, Ivonne; Grönewald, Astrid; Grönewald, Cordt; Berghof-Jäger, Kornelia
2010-03-01
The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.
Singh, Richa Polka; Damle, Satyawan Gangaram; Chawla, Amrita
2011-11-01
To compare the levels of mutans streptococci and lactobacilli in saliva of school children, before and after consumption of probiotic and control ice-cream. A double-blind, cross-over, placebo-controlled trial was carried out in forty, 12-14 year-old children, with no clinically detectable caries. The selected children were randomized equally into two groups I and II. Following an initial run-in period of 1 week, children in group I and II were given ice-creams 'A' and 'B', respectively, for 10 days. Being a cross-over study, the ice-creams were interchanged in the two groups after a 2-week wash-out period. Saliva samples at baseline and follow-up were assessed using Dentocult SM and Dentocult LB kits. On statistical evaluation, it was seen that probiotic ice-cream brought about a statistically significant reduction (p-value = 0.003) in salivary mutans streptococci levels with no significant effect on lactobacilli levels. In conclusion, probiotic ice-cream containing Bifidobacterium lactis Bb-12 ATCC27536 and Lactobacillus acidophilus La-5 can reduce the levels of certain caries-associated micro-organisms in saliva.
Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.
1994-01-01
A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645
Fan, Ying; Wu, Shuo-Dong; Fu, Bei-Bei; Weng, Chao; Wang, Xin-Peng
2014-01-01
To study the changes of interstitial cells of Cajal (ICCs) and expression of c-kt and scf mRNA in terminal ileum tissue during cholesterol gallstone formation in guinea pigs fed on high cholesterol diet, forty guinea pigs were divided into the gallstone group and the control group. The animals in the gallstone group were fed on a high cholesterol diet (HCD), while those in the control group fed on a standard diet (StD). The guinea pigs were sacrificed at the 8th week. The expression of c-kit and scf in terminal ileum were determined by RT-PCR and the morphological characteristics and number of ICCs were observed and calculated by using immunohistochemistry. RT-PCR showed that, compared with the control group, the c-kit and scf mRNA expression levels in the gallstone group were significantly declined. In the animal assay, the decreased number of ICCs was present obviously in the gallstone group. We concluded from the study that decreased number of ICCs, decreased expression of c-kit and scf in terminal ileum are present in guinea pigs fed on high cholesterol diet. The c-kit/scf pathway inhibition might be involved in the decline of intestinal transit function during cholesterol gallstone formation. PMID:24995081
Combating Terrorism Technical Support Office. 2008 Review
2009-01-15
threat object displayed at the operator control unit of the robotic platform. Remote Utility Conversion Kit The Remote Utility Conversion Kit (RUCK) is a...three- dimensional and isometric simulations and games. Develop crowd models, adversarial behavior models, network-based simulations, mini-simulations...Craft-Littoral The modular unmanned surface craft-littoral ( MUSCL ) is a spin- off of EOD/LIC’s Unmanned Reconnaissance Observation Craft, developed
ERIC Educational Resources Information Center
Keihner, Angie Jo; Meigs, Reba; Sugerman, Sharon; Backman, Desiree; Garbolino, Tanya; Mitchell, Patrick
2011-01-01
Objective: Examine the effect of the "California Children's Power Play! Campaign's School Idea & Resource Kits" for fourth/fifth grades on the psychosocial determinants of fruit and vegetable (FV) intake and physical activity (PA). Methods: Randomized, controlled trial (n = 31 low-resource public schools; 1,154 children). Ten…
NASA Technical Reports Server (NTRS)
Hammel, R. L. (Editor); Smith, A. G. (Editor)
1974-01-01
The design and application of a supplementary power and heat rejection kit for the Spacelab are discussed. Two subsystems of electric power and thermal control were analyzed to define the requirements for the power and heat rejection kit (PHRK). Twelve exemplary experiments were defined and power timelines were developed. From these timeline, the experiment requirements for sustained power, peak power, and energy were determined. The electrical power subsystem of the PHRK will consist of two fuel cells, oxygen and hydrogen reactant tank assemblies, water storage tanks, plumbing, cabling, and inverters to convert the nominal 28 volt dc fuel cell output to ac power.
[Multisite validation of CDT measurement by the %CDT TIA and the Tina Quant %CDT kits].
Boehrer, J L; Cano, Y; Capolaghi, B; Desch, G; Dosbaa, I; Estepa, L; Hennache, B; Schellenberg, F
2007-01-01
The measurement of CDT (Carbohydrate Deficient Transferrin) is an essential biological tool in the diagnosis and follow-up of alcohol abuse. It is also employed as a marker of abstinence for the restitution of driving licences. However, the precision of measurement, and the between laboratory homogeneity of the results are still discussed. The ion exchange followed by immunodetermination of CDT is available in two products, the Tina Quant %CDT (Roche, Mannheim, Germany) and the %CDT TIA (Bio-Rad, Hercules, United States). This multicentre study was undertaken: 1) to evaluate the analytical characteristics of these kits and the homogeneity of the results from one laboratory to another, independently of the method used, 2) to validate the differences between the proposed normal values of both kits, 3) to study the possibility of using commercial control sera as external quality control. Four analytical systems were included in the study (Roche Modular/Hitachi 717, Beckman Coulter Immage and LX20, Dade Behring BNII). Determinations were carried out on pools of sera, commercial control sera, kit controls, and 30 serums of patients. These latter were also analyzed in capillary electrophoresis in order to establish correlations between the techniques. The calibrations were stable over one 2 weeks period. The repeatability of measurements spread out from 3,1% to 24,7%, for a mean value lower than 10%. The commercial control sera provided reliable results, with values adapted to a routine quality control use. The results of the Bio-Rad applications were lower by approximately 20% than those of the Roche application, which justifies the difference of the normal values (2,6% versus 3%), and an identical classification of the patients in at least 27 of the 30 samples. We conclude that the analytical quality of the compared techniques, even if it could be improved, is sufficient to guarantee a good reliability of the results. An external quality control could be proposed by using the control sera that we tested.
Preliminary characterization of digestive enzymes in freshwater mussels
Sauey, Blake W.; Amberg, Jon J.; Cooper, Scott T.; Grunwald, Sandra K.; Newton, Teresa J.; Haro, Roger J.
2015-01-01
Resource managers lack an effective chemical tool to control the invasive zebra mussel Dreissena polymorpha. Zebra mussels clog water intakes for hydroelectric companies, harm unionid mussel species, and are believed to be a reservoir of avian botulism. Little is known about the digestive physiology of zebra mussels and unionid mussels. The enzymatic profile of the digestive glands of zebra mussels and native threeridge (Amblema plicata) and plain pocketbook mussels (Lampsilis cardium) are characterized using a commercial enzyme kit, api ZYM, and validated the kit with reagent-grade enzymes. A linear correlation was shown for only one of nineteen enzymes, tested between the api ZYM kit and a specific enzyme kit. Thus, the api ZYM kit should only be used to make general comparisons of enzyme presence and to observe trends in enzyme activities. Enzymatic trends were seen in the unionid mussel species, but not in zebra mussels sampled 32 days apart from the same location. Enzymatic classes, based on substrate, showed different trends, with proteolytic and phospholytic enzymes having the most change in relative enzyme activity.
Growth control of genetically modified cells using an antibody/c-Kit chimera.
Kaneko, Etsuji; Kawahara, Masahiro; Ueda, Hiroshi; Nagamune, Teruyuki
2012-05-01
Gene therapy has been regarded as an innovative potential treatment against serious congenital diseases. However, applications of gene therapy remain limited, partly because its clinical success depends on therapeutic gene-transduced cells acquiring a proliferative advantage. To address this problem, we have developed the antigen-mediated genetically modified cell amplification (AMEGA) system, which uses chimeric receptors to enable the selective proliferation of gene-transduced cells. In this report, we describe mimicry of c-Kit signaling and its application to the AMEGA system. We created an antibody/c-Kit chimera in which the extracellular domain of c-Kit is replaced with an anti-fluorescein single-chain Fv antibody fragment and the extracellular D2 domain of the erythropoietin receptor. A genetically modified mouse pro-B cell line carrying this chimera showed selective expansion in the presence of fluorescein-conjugated BSA (BSA-FL) as a growth inducer. By further engineering the transmembrane domain of the chimera to reduce interchain interaction we attained stricter ligand-dependency. Since c-Kit is an important molecule in the expansion of hematopoietic stem cells (HSCs), this antibody/c-Kit chimera could be a promising tool for gene therapy targeting HSCs. Copyright © 2011 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
Lewnard, Joseph A.; Ndeffo Mbah, Martial L.; Alfaro-Murillo, Jorge A.; Altice, Frederick L.; Bawo, Luke; Nyenswah, Tolbert G.; Galvani, Alison P.
2014-01-01
Background A substantial scale-up in public health response is needed to control the unprecedented Ebola virus disease (EVD) epidemic in West Africa. Current international commitments seek to expand intervention capacity in three areas: new EVD Treatment Centers (ETCs); case ascertainment through contact tracing; and household protective kit allocation. Methods We developed a transmission model of Ebola virus that we fitted to reported EVD cases and deaths in Montserrado County, Liberia. We used this model to evaluate effectiveness of expanding ETCs, improving case ascertainment, and allocating protective kits for controlling the outbreak in Montserrado. Findings We estimated the basic reproductive number for EVD in Montserrado to be 2·49 [2·38–2·60]. We expect that allocating 4,800 additional ETC beds and increasing case ascertainment fivefold in November can avert 77312 [68400–85870] cases relative to the status quo by 15 December. Complementing these measures with protective kit allocation increases the expectation as high as 97940 [90096–105606] cases. If deployed by 15 October, equivalent interventions would have been expected to avert 137432 [129736–145874] cases. If delayed to 15 November, we expect the interventions will at best avert 53957 [49963–60490] cases. Interpretation The number of ETC beds needed to effectively control EVD in Montserrado substantially exceeds the total pledged by the United States to West Africa. Accelerated case ascertainment is required to maximize effectiveness of expanding ETC capacity. Distributing protective kits can further augment EVD prevention. Our findings highlight the rapidly closing window of opportunity for controlling the outbreak and averting a catastrophic toll of EVD cases and deaths. Funding NIH: U01-GM087719, U01-GM105627, K24-DA017072 PMID:25455986
Christy, Shannon M; Davis, Stacy N; Williams, Kimberly R; Zhao, Xiuhua; Govindaraju, Swapomthi K; Quinn, Gwendolyn P; Vadaparampil, Susan T; Lin, Hui-Yi; Sutton, Steven K; Roethzeim, Richard R; Shibata, David; Meade, Cathy D; Gwede, Clement K
2016-11-15
Intervention studies among individuals in diverse community settings are needed to reduce health disparities in colorectal cancer (CRC) screening and mortality rates. The current study compared the efficacy of 2 intervention conditions promoting CRC screening among black individuals. Black individuals ages 50 to 75 years (N = 330) were recruited in community settings in 4 Tampa Bay counties. After obtaining consent and conducting a baseline interview to assess sociodemographic and health-related variables, participants received either a culturally targeted CRC photonovella booklet plus a fecal immunochemical test (FIT) kit or a standard CRC screening brochure plus an FIT kit. The primary outcome was FIT kit screening uptake. FIT screening uptake at 6 months was 86.7% overall (90.3% in the brochure group and 81.9% in the photonovella group). Controlling for baseline between-group differences, there was no influence of intervention on FIT kit uptake (P = .756). Significant predictors of not returning an FIT kit included being unable to work (P = .010), having higher religious belief scores (P = .015), and living farther from the cancer center (P = .015). Providing FIT kits and educational print materials to black individuals in community settings resulted in high rates of CRC screening. The study also identified subgroups of participants who were less likely to return an FIT kit and provides insight for future interventions. Cancer 2016;122:3288-3296. © 2016 American Cancer Society. © 2016 American Cancer Society.
Shen, Cheng-Cheng; Chen, Bing; Gu, Jian-Teng; Ning, Jiao-Lin; Zeng, Jing; Yi, Bin; Lu, Kai-Zhi
2018-03-01
Recent studies have shown that pulmonary angiogenesis is an important pathological process in the development of hepatopulmonary syndrome (HPS), and growing evidence has indicated that Stromal cell-derived factor 1/C-X-C chemokine receptor type 4 (SDF-1/CXCR4) axis is involved in pulmonary vascular disease by mediating the accumulation of c-kit+ cells. This study aimed to test the effect of AMD3100, an antagonist of CXCR4, in HPS pulmonary angiogenesis. Common bile duct ligation (CBDL) rats were used as experimental HPS model and were treated with AMD3100 (1.25mg/kg/day, i.p.) or 0.9% saline for 3weeks. The sham rats underwent common bile duct exposure without ligation. The c-kit+ cells accounts and its angiogenic-related functions, prosurvival signals, pulmonary angiogenesis and arterial oxygenation were analysed in these groups. Our results showed that pulmonary SDF-1/CXCR4, Akt, Erk and VEGF/VEGFR2 were significantly activated in CBDL rats, and the numbers of circulating and pulmonary c-kit+ cells were increased in CBDL rats compared with control rats. Additionally, the angiogenic-related functions of c-kit+ cells and pulmonary microvessel counts were also elevated in CBDL rats. CXCR4 inhibition reduced pulmonary c-kit+ cells and microvessel counts and improved arterial oxygenation within 3weeks in CBDL rats. The pulmonary prosurvival signals and pro-angiogenic activity of c-kit+ cells were also down-regulated in AMD3100-treated rats. In conclusion, AMD3100 treatment attenuated pulmonary angiogenesis in CBDL rats and prevented the development of HPS via reductions in pulmonary c-kit+ cells and inhibition of the prosurvival signals. Our study provides new insights in HPS treatment. Copyright © 2017. Published by Elsevier B.V.
A Frameshift Mutation in KIT is Associated with White Spotting in the Arabian Camel.
Holl, Heather; Isaza, Ramiro; Mohamoud, Yasmin; Ahmed, Ayeda; Almathen, Faisal; Youcef, Cherifi; Gaouar, Semir; Antczak, Douglas F; Brooks, Samantha
2017-03-09
While the typical Arabian camel is characterized by a single colored coat, there are rare populations with white spotting patterns. White spotting coat patterns are found in virtually all domesticated species, but are rare in wild species. Theories suggest that white spotting is linked to the domestication process, and is occasionally associated with health disorders. Though mutations have been found in a diverse array of species, fewer than 30 genes have been associated with spotting patterns, thus providing a key set of candidate genes for the Arabian camel. We obtained 26 spotted camels and 24 solid controls for candidate gene analysis. One spotted and eight solid camels were whole genome sequenced as part of a separate project. The spotted camel was heterozygous for a frameshift deletion in KIT (c.1842delG, named KITW1 for White spotting 1), whereas all other camels were wild-type (KIT+/KIT+). No additional mutations unique to the spotted camel were detected in the EDNRB, EDN3, SOX10, KITLG, PDGFRA, MITF, and PAX3 candidate white spotting genes. Sanger sequencing of the study population identified an additional five kITW1/KIT+ spotted camels. The frameshift results in a premature stop codon five amino acids downstream, thus terminating KIT at the tyrosine kinase domain. An additional 13 spotted camels tested KIT+/KIT+, but due to phenotypic differences when compared to the KITW1/KIT+ camels, they likely represent an independent mutation. Our study suggests that there are at least two causes of white spotting in the Arabian camel, the newly described KITW1 allele and an uncharacterized mutation.
Bienek, Diane R; Charlton, David G
2012-05-01
Being able to test for the presence of blood pathogens at forward locations could reduce morbidity and mortality in the field. Rapid, user-friendly blood typing kits for detecting Human Immunodeficiency Virus (HIV), Hepatitis C Virus (HCV), and Hepatitis B Virus (HBV) were evaluated to determine their accuracy after storage at various temperatures/humidities. Rates of positive tests of control groups, experimental groups, and industry standards were compared (Fisher's exact chi2, p < or = 0.05). Compared to the control group, 2 of 10 HIV detection devices were adversely affected by exposure to high temperature/high humidity or high temperature/low humidity. With one exception, none of the environmentally exposed HCV or HBV detection devices exhibited significant differences compared to those stored under control conditions. For HIV, HCV, and HBV devices, there were differences compared to the industry standard. Collectively, this evaluation of pathogen detection kits revealed that diagnostic performance varies among products and storage conditions, and that the tested products cannot be considered to be approved for use to screen blood, plasma, cell, or tissue donors.
Leontiou, Chrysanthia A.; Hadjidaniel, Michael D.; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C.
2015-01-01
Introduction Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Methods Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. Results The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Conclusion Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions. PMID:26247357
Leontiou, Chrysanthia A; Hadjidaniel, Michael D; Mina, Petros; Antoniou, Pavlos; Ioannides, Marios; Patsalis, Philippos C
2015-01-01
Epigenetic alterations, including DNA methylation, play an important role in the regulation of gene expression. Several methods exist for evaluating DNA methylation, but bisulfite sequencing remains the gold standard by which base-pair resolution of CpG methylation is achieved. The challenge of the method is that the desired outcome (conversion of unmethylated cytosines) positively correlates with the undesired side effects (DNA degradation and inappropriate conversion), thus several commercial kits try to adjust a balance between the two. The aim of this study was to compare the performance of four bisulfite conversion kits [Premium Bisulfite kit (Diagenode), EpiTect Bisulfite kit (Qiagen), MethylEdge Bisulfite Conversion System (Promega) and BisulFlash DNA Modification kit (Epigentek)] regarding conversion efficiency, DNA degradation and conversion specificity. Performance was tested by combining fully methylated and fully unmethylated λ-DNA controls in a series of spikes by means of Sanger sequencing (0%, 25%, 50% and 100% methylated spikes) and Next-Generation Sequencing (0%, 3%, 5%, 7%, 10%, 25%, 50% and 100% methylated spikes). We also studied the methylation status of two of our previously published differentially methylated regions (DMRs) at base resolution by using spikes of chorionic villus sample in whole blood. The kits studied showed different but comparable results regarding DNA degradation, conversion efficiency and conversion specificity. However, the best performance was observed with the MethylEdge Bisulfite Conversion System (Promega) followed by the Premium Bisulfite kit (Diagenode). The DMRs, EP6 and EP10, were confirmed to be hypermethylated in the CVS and hypomethylated in whole blood. Our findings indicate that the MethylEdge Bisulfite Conversion System (Promega) was shown to have the best performance among the kits. In addition, the methylation level of two of our DMRs, EP6 and EP10, was confirmed. Finally, we showed that bisulfite amplicon sequencing is a suitable approach for methylation analysis of targeted regions.
NASA Technical Reports Server (NTRS)
1988-01-01
M.H. Marks Enterprises' Power Factor Controller (PFC) matches voltage with motor's actual need. Plugged into a motor, PFC continuously determines motor load by sensing shifts between voltage and current flow. When it senses a light load, it cuts voltage to the minimum needed. It offers potential energy savings ranging from eight percent up to 65 percent depending on the application. Myles Marks started out with the notion of writing an article for Popular Electronics magazine at the same time offering to furnish kits to readers interested in assembling PFC's. Within two weeks from publication he had orders for 500 kits and orders are still coming three years later.
Zhang, Wenchang; Wu, Tingting; Zhang, Chenyun; Luo, Lingfeng; Xie, Meimei; Huang, Huiling
2017-10-05
Since the 1990s, the rising problem that gonad reproductive toxicity on adult female after exposing to cadmium (Cd), an environmental endocrine disruptor, has attracted high attention at home and abroad,and was systematically studied. Our research focuses on a further problem is that early cadmium exposure (during birth to before puberty) impact on development and function of ovarian cells and its possible mechanism. Our research focuses on the changes of ovarian cells growth and development after the newborn rat ovaries with cadmium exposure in vitro, and different expression of ovarian cells development-related factors, SCF/c-kit and changes of their DNA methylation status. We obtained ovaries from 4-day-old SD rats and cultured them in DMEM/F12 mixed with α-MEM media in vitro. Different doses of cadmium were designed as control, 0.5, 5, 10 and 50μM, and then the constituent ratio of ovarian follicle and follicular oocytes diameter were observed with microscope after 4-h exposure. We found that the increased constituent ratio of original follicle and decreased diameter of all levels of follicular oocytes(compared with control, with statistically significant differences, P<0.01).After the measurement of expression of SCF/c-kit by qRT-PCR and Western Blotting, the mRNA and protein expression of SCF/c-kit in ovarian were both decreased. We further found that the increased constituent ratio of growth follicle and increased diameter of oocytes under the treatment of adding SCF in cell culture media. Finally, MALDI-TOF-MS method showed DNA-low methylation status of SCF/c-kit promoter region after Cd exposure. Overall, we concluded that the exposure of cadimium (5-50μM) on newborn rats ovaries could inhibit follicle development.SCF/c-kit system might mediate follicle development damage caused by cadmium, which is associated with DNA hypomethylation of SCF/c-kit promoter region may be worthy of further study. Copyright © 2017. Published by Elsevier B.V.
JMS Proxy and C/C++ Client SDK
NASA Technical Reports Server (NTRS)
Wolgast, Paul; Pechkam, Paul
2007-01-01
JMS Proxy and C/C++ Client SDK (JMS signifies "Java messaging service" and "SDK" signifies "software development kit") is a software package for developing interfaces that enable legacy programs (here denoted "clients") written in the C and C++ languages to communicate with each other via a JMS broker. This package consists of two main components: the JMS proxy server component and the client C library SDK component. The JMS proxy server component implements a native Java process that receives and responds to requests from clients. This component can run on any computer that supports Java and a JMS client. The client C library SDK component is used to develop a JMS client program running in each affected C or C++ environment, without need for running a Java virtual machine in the affected computer. A C client program developed by use of this SDK has most of the quality-of-service characteristics of standard Java-based client programs, including the following: Durable subscriptions; Asynchronous message receipt; Such standard JMS message qualities as "TimeToLive," "Message Properties," and "DeliveryMode" (as the quoted terms are defined in previously published JMS documentation); and Automatic reconnection of a JMS proxy to a restarted JMS broker.
Comparison of three control methods for an autonomous vehicle
NASA Astrophysics Data System (ADS)
Deshpande, Anup; Mathur, Kovid; Hall, Ernest
2010-01-01
The desirability and challenge of developing a completely autonomous vehicle and the rising need for more efficient use of energy by automobiles motivate this research- a study for an optimum solution to computer control of energy efficient vehicles. The purpose of this paper is to compare three control methods - mechanical, hydraulic and electric that have been used to convert an experimental all terrain vehicle to drive by wire which would eventually act as a test bed for conducting research on various technologies for autonomous operation. Computer control of basic operations in a vehicle namely steering, braking and speed control have been implemented and will be described in this paper. The output from a 3 axis motion controller is used for this purpose. The motion controller is interfaced with a software program using WSDK (Windows Servo Design Kit) as an intermediate tuning layer for tuning and parameter settings in autonomous operation. The software program is developed in C++. The voltage signal sent to the motion controller can be varied through the control program for desired results in controlling the steering motor, activating the hydraulic brakes and varying the vehicle's speed. The vehicle has been tested for its basic functionality which includes testing of street legal operations and also a 1000 mile test while running in a hybrid mode. The vehicle has also been tested for control when it is interfaced with devices such as a keyboard, joystick and sensors under full autonomous operation. The vehicle is currently being tested in various safety studies and is being used as a test bed for experiments in control courses and research studies. The significance of this research is in providing a greater understanding of conventional driving controls and the possibility of improving automobile safety by removing human error in control of a motor vehicle.
NASA Astrophysics Data System (ADS)
Lang, A.; Wesely, N.; Soós, B.; Sléber, B.; Majnovics, Z.; Ettingshausen, M.; Bodnár, L.; Németh, A.; Roos, M.
2011-10-01
In our school works a course in robotics where students build and program robots from a LEGO MINDSTORMS kit. We took part in the Hunveyor- Husar project with a Mars rover based on a rover model kit, of which the operating arms are built out of LEGO and controlled by an MINDSTORMS NXT computer. We presented our rover on the EPSC in Rome last September 2010 We presented our rover on the EPSC in Rome in September 2010. At that same conference the "Rosetta's Comet Touchdown" educational kit was officially presented. We were very interested and in conversation with the people from the project, we agreed that our school in Sopron would also participate in testing the kit. . The kit comes with a set of Interdisciplinary Activity Sheets (IAS, downloadable from Vimeo channel1) and a great feature is that the proposed activities in the IAS cover three areas: science, art/history and engineering. The 31 students from our class divided up in groups and each group chose a different topic: History of comets in Hungarian culture; Designing a T-shirt; Research on comets; Hungary in the Rosetta mission; Animation of Rosetta's orbit in space; building a LEGO MINDSTORM model; a film was made of the activities . In this presentation we report in particular the activities of the LEGO building team.
Liu, Chao; Ouyang, Wei; Xia, Jingyan; Sun, Xiaoru; Zhao, Liying; Xu, Feng
2018-06-05
Mast cells (MCs) play a key role in immune process response to invading pathogens. This study assessed the involvement of MCs in controlling Staphylococcus aureus infection in a cutaneous infection model of MC-deficient (KitW-sh/W-sh) mice. KitW-sh/W-sh mice developed significantly larger skin lesions after the cutaneous S. aureus challenge, when compared to wild-type (WT) mice, while MC dysfunction reduced the inflammation response to S. aureus. The levels of tumor necrosis factor (TNF)-α in skin tissues were significantly decreased in KitW-sh/W-sh mice upon infection. Moreover, the exogenous administration of MCs or recombinant TNF-α effectively restored the immune response against S. aureus in KitW-sh/W-sh mice via the recruitment of neutrophils to the infected site. These results indicate that the effects of MC deficiency are largely attributed to the decrease in production of TNF-α in cutaneous S. aureus infection. In addition, S. aureus-induced MC activation was dependent on the c-kit receptor-activated phosphoinositide 3-kinase (PI3K)/AKT/P65-nuclear factor (NF-κB) pathway, which was confirmed by treatment with Masitinib (a c-kit receptor inhibitor), Wortmannin (a PI3K inhibitor), and pyrrolidine dithiocarbamate (a NF-κB inhibitor), respectively. The present study identifies the critical role of MCs in the host defense against S. aureus infection.
Ahmadi, Saharnaz; Farokhi, Maryam; Padidar, Parisa; Falahati, Mojtaba
2015-01-01
In this study the effect of surface modification of mesoporous silica nanoparticles (MSNs) on its adsorption capacities and protein stability after immobilization of beta-lactoglobulin B (BLG-B) was investigated. For this purpose, non-functionalized (KIT-6) and aminopropyl-functionalized cubic Ia3d mesoporous silica ([n-PrNH2-KIT-6]) nanoparticles were used as nanoporous supports. Aminopropyl-functionalized mesoporous nanoparticles exhibited more potential candidates for BLG-B adsorption and minimum BLG leaching than non-functionalized nanoparticles. It was observed that the amount of adsorbed BLG is dependent on the initial BLG concentration for both KIT-6 and [n-PrNH2-KIT-6] mesoporous nanoparticles. Also larger amounts of BLG-B on KIT-6 was immobilized upon raising the temperature of the medium from 4 to 55 °C while such increase was undetectable in the case of immobilization of BLG-B on the [n-PrNH2-KIT-6]. At temperatures above 55 °C the amounts of adsorbed BLG on both studied nanomaterials decreased significantly. By Differential scanning calorimetry or DSC analysis the heterogeneity of the protein solution and increase in Tm may indicate that immobilization of BLG-B onto the modified KIT-6 results in higher thermal stability compared to unmodified one. The obtained results provide several crucial factors in determining the mechanism(s) of protein adsorption and stability on the nanostructured solid supports and the development of engineered nano-biomaterials for controlled drug-delivery systems and biomimetic interfaces for the immobilization of living cells. PMID:26230687
Dhingra, Vandana Kumar; Saini, Sunil; Basu, Sandip
2015-01-01
We describe and discuss the various medical, social and financial aspects of setting up, and optimizing, working conditions of a tertiary Nuclear Medicine Department. This department was established in a North Indian state which comprises 93% of hilly area. During the first three years after establishment we have developed infrastructure, cooperation with other departments, improved radiation safety and cost effectiveness of our work and designed future perspectives. The facility was established in a cancer center of a tertiary care hospital where a medical college infrastructure was developed. National guidelines formulated by the Atomic Energy Regulatory Board (AERB) were followed. Our department served a population area of 10.08 million inhabitants. Over the first three years 2,400 patients underwent diagnostic scans and 106 patients underwent low dose radioiodine treatment for thyrotoxicosis. To optimize resources and at the same time, enhance their effectivity, we procured our (99)Mo/ (99m)Tc generator every other week and arranged our daily programme accordingly. Fractionation of cold kits allowed us to perform low cost in-vivo procedures on a daily basis and to save the department's running costs by 30%-50%. We run continuing education nuclear medicine programmes for referring physicians, medical students and paramedical workers which were included in routine practice which led to a consistent growth in patients referral. The need for a positron emission tomography/computed tomography (PET/CT) scan and high dose treatment department for thyroid cancer was strongly felt. Our nuclear medicine department in a peripheral region of a developing country applied better logistics by procuring new generator every fortnight, fractionating the cold kits and by organizing complete teaching programmes.
DEMONSTRATION AND QUALITY ASSURANCE PROJECT ...
The demonstration of technologies for determining the presence of dioxin in soil and sediment is being conducted under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in Saginaw, Michigan, at Green Point Environmental Learning Center from approximately April 26 to May 6, 2004. The primary purpose of the demonstration is to evaluate innovative monitoring technologies. The technologies listed below will be demonstrated. .AhRC PCRTM Kit, Hybrizyme Corporation .Ah-IMMUNOASSY@ Kit, Paralsian, Inc. .Coplanar PCB Immunoassay Kit, Abraxis LLC .DF-l Dioxin/Furan Immunoassay Kit, CAPE Technologies L.L.C. .CALUX@ by Xenobiotic Detection Systems, Inc- .Dioxin ELISA Kit, Wako Pure Chemical Industries LTD. This demonstration plan describes the procedures that will be used to verify the performance and cost of these technologies. The plan incorporates the quality assurance and quality control elements needed to generate data of sufficient quality to document each technology's performance and cost. A separate innovative technology verification report (ITVR) will.be prepared for each technology. The ITVRs will present the demonstration findings associated with the demonstration objectives. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Yin, Dan-Dan; Luo, Jun-Hui; Zhao, Zhu-Ye; Liao, Ying-Jun; Li, Ying
2018-05-01
Renal interstitial fibrosis is a final pathway that is observed in various types of kidney diseases, including diabetic kidney disease (DKD). The present study investigated the effect of tranilast on renal interstitial fibrosis and the association between its role and mast cell infiltration in a rat model of DKD. A total of 30 healthy 6‑week‑old male Sprague‑Dawley rats were randomly divided into the following four groups: Normal control group; DKD model group; low‑dose tranilast group (200 mg/kg/day); and high‑dose tranilast group (400 mg/kg/day). The morphological alterations of tubulointerstitial fibrosis were evaluated by Masson's trichrome staining, while mast cell infiltration into the renal tubular interstitium was measured by toluidine blue staining and complement C3a receptor 1 (C3aR) immunohistochemical staining (IHC). The expression of fibronectin (FN), collagen I (Col‑I), stem cell factor (SCF) and proto‑oncogene c‑kit (c‑kit) was detected by IHC, western blotting and reverse transcription‑quantitative‑polymerase chain reaction. The results demonstrated that tubulointerstitial fibrosis and mast cell infiltration were observed in DKD model rats, and this was improved dose‑dependently in the tranilast treatment groups. The expression of FN, Col‑I, SCF and c‑kit mRNA and protein was upregulated in the tubulointerstitium of DKD model rats compared with the normal control rats, and tranilast inhibited the upregulated expression of these markers. Furthermore, the degree of SCF and c‑kit expression demonstrated a significant positive correlation with C3aR‑positive mast cells and the markers of renal interstitial fibrosis. The results of the present study indicate that mast cell infiltration may promote renal interstitial fibrosis via the SCF/c‑kit signaling pathway. Tranilast may prevent renal interstitial fibrosis through inhibition of mast cell infiltration mediated through the SCF/c-kit signaling pathway.
Woodhall, Sarah C; Nichols, Tom; Alexander, Sarah; da Silva, Filomeno Coelho; Mercer, Catherine H; Ison, Catherine; Gill, O Noel; Soldan, Kate
2015-09-01
Chlamydia prevalence in the general population is a potential outcome measure for the evaluation of chlamydia control programmes. We carried out a pilot study to determine the feasibility of using a postal survey for population-based chlamydia prevalence monitoring. Postal invitations were sent to a random sample of 2000 17-year-old to 18-year-old women registered with a general practitioner in two pilot areas in England. Recipients were randomised to receive either a self-sampling kit (n=1000), a self-sampling kit and offer of £5 voucher on return of sample (n=500) or a self-sampling kit on request (n=500). Participants returned a questionnaire and self-taken vulvovaginal swab sample for unlinked anonymous Chlamydia trachomatis testing. Non-responders were sent a reminder letter 3 weeks after initial invitation. We calculated the participation rate (number of samples returned/number of invitations sent) and cost per sample returned (including cost of consumables and postage) in each group. A total of 155/2000 (7.8%) samples were returned with consent for testing. Participation rates varied by invitation group: 7.8% in the group who were provided with a self-sampling kit, 14% in the group who were also offered a voucher and 1.0% in the group who were not sent a kit. The cost per sample received was lowest (£36) in the group who were offered both a kit and a voucher. The piloted survey methodology achieved low participation rates. This approach is not suitable for population-based monitoring of chlamydia prevalence among young women in England. (UKCRN ID 10913). Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
On-farm biosecurity practices and causes of preweaning mortality in Canadian commercial mink kits.
Compo, Nicole; Pearl, David L; Tapscott, Brian; Storer, Amanda; Hammermueller, Jutta; Brash, Marina; Turner, Patricia V
2017-09-08
Mink are an important animal commodity group in Canada and excessive kit mortality represents a significant loss to production. National biosecurity standards have been developed for Canadian mink farms, but it is unclear how well these standards have been implemented as there are no studies correlating management practices of mink producers with causes of death in mink kits. To that end, we surveyed Ontario mink producers on their biosecurity and management practices and conducted almost 5660 post mortem examinations on found-dead, preweaned kits to characterize mink farm biosecurity practices and causes of death in preweaned kits. We found that very few biosecurity and management practices were uniformly used by producers, despite good awareness of appropriate practices. Use of personal protective equipment was implemented by fewer than 50% of respondents, while control of mink shed access, disinfection of feed containers after use, and use of a rodent control program were the only practices implemented by greater than 70% of respondents. Only 18% of producers reported regular use of antimicrobials in feed or water, although 91% stated they used antimicrobials for treatment of bacterial diseases on a regular basis. On post mortem examination, no gross abnormalities were noted in 71% of the kits, 45% were thought to be stillborn or aborted, 27% had some form of abnormal fluid distribution in the body, and 2% had a congenital malformation. A subset of 69 gastrointestinal tract samples was submitted for bacterial culture, of which 45 samples yielded sufficient growth. Most interesting was the identification of Salmonella enterica serovar Heidelberg in 11% of samples. The results of this study will provide a benchmark for Canadian mink producers and their veterinarians, defining the areas to which greater attention should be given to ensure more rigorous biosecurity practices are in place. Ultimately, these improvements in practices may contribute to increased mink production and animal well-being.
Stability of Formulations Contained in the Pharmaceutical Payload Aboard Space Missions
NASA Technical Reports Server (NTRS)
Putcha, Lakshmi; Du, Brian; Daniels, Vernie; Boyd, Jason L.; Crady, Camille; Satterfield, Rick
2008-01-01
Efficacious pharmaceuticals with adequate shelf life are essential for successful space medical operations in support of space exploration missions. Physical and environmental factors unique to space missions such as vibration, G forces and ionizing radiation may adversely affect stability of pharmaceuticals intended for standard care of astronauts aboard space missions. Stable pharmaceuticals, therefore, are of paramount importance for assuring health and wellness of astronauts in space. Preliminary examination of stability of formulations from Shuttle and International Space Station (ISS) medical kits revealed that some of these medications showed physical and chemical degradation after flight raising concern of reduced therapeutic effectiveness with these medications in space. A research payload experiment was conducted with a select set of formulations stowed aboard a shuttle flight and on ISS. The payload consisted of four identical pharmaceutical kits containing 31 medications in different dosage forms that were transported to the International Space Station (ISS) aboard the Space Shuttle, STS 121. One of the four kits was stored on the shuttle and the other three were stored on the ISS for return to Earth at six months intervals on a pre-designated Shuttle flight for each kit; the shuttle kit was returned to Earth on the same flight. Standard stability indicating physical and chemical parameters were measured for all pharmaceuticals returned from the shuttle and from the first ISS increment payload along with ground-based matching controls. Results were compared between shuttle, ISS and ground controls. Evaluation of data from the three paradigms indicates that some of the formulations exhibited significant degradation in space compared to respective ground controls; a few formulations were unstable both on the ground and in space. An increase in the number of pharmaceuticals from ISS failing USP standards was noticed compared to those from the shuttle flight. A comprehensive evaluation of results is in progress.
49 CFR 173.161 - Chemical kits and first aid kits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...
Enabling a Scientific Cloud Marketplace: VGL (Invited)
NASA Astrophysics Data System (ADS)
Fraser, R.; Woodcock, R.; Wyborn, L. A.; Vote, J.; Rankine, T.; Cox, S. J.
2013-12-01
The Virtual Geophysics Laboratory (VGL) provides a flexible, web based environment where researchers can browse data and use a variety of scientific software packaged into tool kits that run in the Cloud. Both data and tool kits are published by multiple researchers and registered with the VGL infrastructure forming a data and application marketplace. The VGL provides the basic work flow of Discovery and Access to the disparate data sources and a Library for tool kits and scripting to drive the scientific codes. Computation is then performed on the Research or Commercial Clouds. Provenance information is collected throughout the work flow and can be published alongside the results allowing for experiment comparison and sharing with other researchers. VGL's "mix and match" approach to data, computational resources and scientific codes, enables a dynamic approach to scientific collaboration. VGL allows scientists to publish their specific contribution, be it data, code, compute or work flow, knowing the VGL framework will provide other components needed for a complete application. Other scientists can choose the pieces that suit them best to assemble an experiment. The coarse grain workflow of the VGL framework combined with the flexibility of the scripting library and computational toolkits allows for significant customisation and sharing amongst the community. The VGL utilises the cloud computational and storage resources from the Australian academic research cloud provided by the NeCTAR initiative and a large variety of data accessible from national and state agencies via the Spatial Information Services Stack (SISS - http://siss.auscope.org). VGL v1.2 screenshot - http://vgl.auscope.org
49 CFR 173.161 - Chemical kits and first aid kits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Applicability. Chemical kits and first aid kits... assigned to the chemical kit and first aid kit as a whole must be the most stringent packing group assigned...
NASA Astrophysics Data System (ADS)
Ampiah-Bonney, Richmond Jerry
Two manifolds were designed to determine phosphate concentrations. The linear range for the 2-channel manifold was 0 to 30 mg L-1, and that for the 3-channel manifold was 0 to 400 mg L-1. Optimized conditions for the determination of arsenic with molybdenum-blue method were 0.5% w/v ascorbic acid, 0.4 M sulfuric acid in the molybdate solution and 80°C reaction temperature. A method for determination of arsenic using pervaporation flow injection hydride generation with visible spectrophotometry was developed. The method was sensitive for low arsenic concentrations (≤ 10 mug L-1), with sensitivity decreasing as arsenic concentration increased. There was no heating required, and the pervaporation membrane transferred only arsine. The analytical performance of two arsenic test kits was assessed. The Alpha Environmental kit cannot be recommended for arsenic measurement in water. The Hach kit was reliable for measuring arsenic concentrations greater than 70 mug L-1. A modified reaction tube was constructed that allowed NaBH4 solution to be delivered into the reaction mixture to replace zinc powder in the Hach kit, with no loss of gases. A more quantitative way of measuring arsenic using the Hach kit was developed by measuring the B-value of the color of jpeg images of test strips taken by a desktop scanner. Leersia oryzoides grown in soil amended with 110 mg kg-1arsenic extracted up to 305 mug g-1 and 272 mug g-1 arsenic into its shoots and roots respectively, giving a shoot:root quotient (SRQ) of 1.12 and phytoextraction coefficients (PEC) up to 1.3 in greenhouse experiments. Five supervised arsenic-related projects were reported. All except one of these reports fell short of the standards acceptable for a publishable manuscript. Factors such as high expectations, competitive entrance requirements and good motivation were responsible for the publishable report. For the remaining reports, problems with working in a team, relatively low expectations and lack of motivation were responsible. A laboratory-based research subject was successfully investigated in middle school classrooms. The program had been run for four consecutive years. Collaboration with the classroom teacher ensured that the program agreed with the school curriculum. All participants recommended continuation of this program.
CDC Vital Signs: Blood Pressure Control -- Helping Patients Take Their Medicine
... Kit Read the MMWR Science Clips Blood Pressure Control Helping Patients Take Their Medicine Language: English (US) ... pressure and only about half have it under control (less than 140/90 mmHg). Blood pressure medicine ( ...
Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P
2008-07-27
A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.
The identification of specialized pacemaking cells in the anal sphincters.
Shafik, Ahmed; El Sibai, Olfat; Ahmed, Ismail
2006-07-01
Interstitial cells of Cajal (ICC) are claimed to generate the electrical activity in the colon and stomach. As the external (EAS) and internal (IAS) anal sphincters exhibit resting electrical activity, we hypothesized the presence of ICC in these sphincters. This hypothesis was investigated in the current study. Specimens from the EAS and IAS were taken from normal areas of the anorectum which had been surgically excised by abdominoperineal operation for rectal cancer of 28 patients (16 men, 12 women, mean age 42.2+/-4.8 years). The specimens were subjected to c-kit immunohistochemistry. Controls for the specificity of the antisera consisted of tissue incubation with normal rabbit serum substituted for the primary antiserum. Fusiform, c-kit positive, ICC-like cells were detected in the anal sphincters; they had dendritic processes. They were clearly distinguishable from the non-branching, c-kit negative smooth and striated muscle cells of the anal sphincters. The specimens contained also c-kit positive mast cells, but they had a rounded body with no dendritic processes. Immunoreactivity was absent in negative controls in which the primary antibody was omitted. We have identified, for the first time, cells in EAS and IAS with morphological and immunological phenotypes similar to ICCs of the gut. These cells appear to be responsible for initiating the slow waves recorded from the anal sphincters and for controlling their activity. A deficiency or absence of these cells may affect the anal motile activity. Studies are needed to explore the role of these cells in anal motility disorders.
Goecker, Zachary C; Swiontek, Stephen E; Lakhtakia, Akhlesh; Roy, Reena
2016-06-01
The development techniques employed to visualize fingerprints collected from crime scenes as well as post-development ageing may result in the degradation of the DNA present in low quantities in such evidence samples. Amplification of the DNA samples with short tandem repeat (STR) amplification kits may result in partial DNA profiles. A comparative study of two commercially available quantification kits, Quantifiler(®) Trio and InnoQuant™, was performed on latent fingerprint samples that were either (i) developed using one of three different techniques and then aged in ambient conditions or (ii) undeveloped and then aged in ambient conditions. The three fingerprint development techniques used were: cyanoacrylate fuming, dusting with black powder, and the columnar-thin-film (CTF) technique. In order to determine the differences between the expected quantities and actual quantities of DNA, manually degraded samples generated by controlled exposure of DNA standards to ultraviolet radiation were also analyzed. A total of 144 fingerprint and 42 manually degraded DNA samples were processed in this study. The results indicate that the InnoQuant™ kit is capable of producing higher degradation ratios compared to the Quantifiler(®) Trio kit. This was an expected result since the degradation ratio is a relative value specific for a kit based on the length and extent of amplification of the two amplicons that vary from one kit to the other. Additionally, samples with lower concentrations of DNA yielded non-linear relationships of degradation ratio with the duration of aging, whereas samples with higher concentrations of DNA yielded quasi-linear relationships. None of the three development techniques produced a noticeably different degradation pattern when compared to undeveloped fingerprints, and therefore do not impede downstream DNA analysis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Flores, Shahida; Sun, Jie; King, Jonathan; Budowle, Bruce
2014-05-01
The GlobalFiler™ Express PCR Amplification Kit uses 6-dye fluorescent chemistry to enable multiplexing of 21 autosomal STRs, 1 Y-STR, 1 Y-indel and the sex-determining marker amelogenin. The kit is specifically designed for processing reference DNA samples in a high throughput manner. Validation studies were conducted to assess the performance and define the limitations of this direct amplification kit for typing blood and buccal reference DNA samples on various punchable collection media. Studies included thermal cycling sensitivity, reproducibility, precision, sensitivity of detection, minimum detection threshold, system contamination, stochastic threshold and concordance. Results showed that optimal amplification and injection parameters for a 1.2mm punch from blood and buccal samples were 27 and 28 cycles, respectively, combined with a 12s injection on an ABI 3500xL Genetic Analyzer. Minimum detection thresholds were set at 100 and 120RFUs for 27 and 28 cycles, respectively, and it was suggested that data from positive amplification controls provided a better threshold representation. Stochastic thresholds were set at 250 and 400RFUs for 27 and 28 cycles, respectively, as stochastic effects increased with cycle number. The minimum amount of input DNA resulting in a full profile was 0.5ng, however, the optimum range determined was 2.5-10ng. Profile quality from the GlobalFiler™ Express Kit and the previously validated AmpFlSTR(®) Identifiler(®) Direct Kit was comparable. The validation data support that reliable DNA typing results from reference DNA samples can be obtained using the GlobalFiler™ Express PCR Amplification Kit. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Mallia, Madhava B; Shinto, Ajit Sugunan; Kameswaran, Mythili; Kamaleshwaran, Koramadai Karuppusamy; Kalarikal, Radhakrishnan; Aswathy, K K; Banerjee, Sharmila
2016-05-01
(188)Re-HEDP is an established radiopharmaceutical used for pain palliation in patients with osseous metastasis. Considering commercial availability of (188)W/(188)Re generator, the accessibility to a lyophilized kit would make preparation of this radiopharmaceutical feasible at the hospital radiopharmacy having access to a generator. A protocol for the preparation of a single-vial lyophilized hydroxyethane 1,1-diphosphonic acid (HEDP) kit was developed and its consistency was checked by preparing six batches. Each sterile lyophilized kit prepared as per the protocol contained 9 mg of HEDP, 3 mg of gentisic acid, and 4 mg of SnCl2.2H2O. Randomly selected kits from all six batches were subjected to thorough quality control tests that were passed by all batches. (188)Re-HEDP could be prepared by addition of 1 mL of freshly eluted Na(188)ReO4 (up to 3700 MBq) containing 1 μmol of carrier ReO4(-) (perrhenate) and heating at 100°C for 15 minutes. (188)Re-HEDP with >95% radiochemical purity could be consistently prepared using the lyophilized kits. Sterile (188)Re-HEDP prepared using the lyophilized kit was evaluated in patients with osseous metastasis. Post-therapy images of the patient were compared with (99m)Tc-MDP bone scan and found to be satisfactory. The bone-to-background as well as tumor-to-normal bone uptake ratio was found to be significant. All patients who received therapy reported significant pain relief within a week to 10 days post-administration of (188)Re-HEDP.
Catomeris, Peter; Baxter, Nancy N; Boss, Sheila C; Paszat, Lawrence F; Rabeneck, Linda; Randell, Edward; Serenity, Mardie L; Sutradhar, Rinku; Tinmouth, Jill
2018-01-01
- Although promising for colorectal cancer screening, hemoglobin (Hb) stability remains a concern with fecal immunochemical tests. This study implemented a novel, standardized method to compare Hb stability across various fecal immunochemical tests. The method can be used to inform decisions when selecting a kit for use in colorectal cancer screening. In so doing, this work addressed a critical need for standardization in this field. - To compare the stability of Hb across 5 different immunochemical kits and one guaiac kit. - The stability of Hb was analyzed in collection devices inoculated with Hb-spiked feces and (1) stored at various temperatures (frozen, refrigerated, ambient, and elevated) for more than 60 days; (2) after undergoing 3 controlled, freeze-thaw cycles; and (3) after being transported by courier or postal services in uncontrolled temperature conditions from 3 locations in Ontario, Canada, to a central testing center. - The stability of Hb varied with time and temperature and by kit. Lower Hb recoveries occurred with increasing temperature and increasing time from sample collection to testing. Refrigeration provided the best stability, although results varied across kits (eg, from 4.2 days to >60 days before a prespecified threshold [<70% probability of the test results remaining positive] was reached). Freeze-thaw stability varied across kits and cycles (Hb recoveries: NS Plus [Alfresa Pharma, Chuo-ku, Osaka, Japan], 91.7% to 95.4%; OC Diana [Eiken Chemical, Taito-ku, Tokyo, Japan], 57.6% to 74.9%). Agreement regarding Hb levels before and after transportation varied across kits (from 57% to 100%). - Important differences in Hb stability were found across the included fecal immunochemical tests. These findings should inform practice-based and population-based colorectal cancer screening.
Ballard, Ariane; Le May, Sylvie; Khadra, Christelle; Lachance Fiola, Jacinthe; Charette, Sylvie; Charest, Marie-Claude; Gagnon, Hélène; Bailey, Benoit; Villeneuve, Edith; Tsimicalis, Argerie
2017-12-01
To assess the feasibility, usefulness, and acceptability of using distraction kits, tailored to age, for procedural pain management of young children visiting the emergency department and requiring a needle-related procedure. A pre-experimental design was piloted. A kit, tailored to age (infants-toddlers: 3 months-2 years; preschoolers: 3-5 years), was provided to parents before their child's needle-related procedure. Data was collected to assess feasibility, usefulness, and acceptability of the kits by parents and nurses. Pain was measured pre-, peri-, and postprocedure using the Face, Legs, Activity, Cry, Consolability scale. A total of 25 infants and toddlers (mean age: 1.4 ± .7 years) and 25 preschoolers (mean age: 4.0 ± .9) participated in the study. Parents and nurses considered the kits useful and acceptable for distraction in the emergency department, especially in the postprocedural period. Addition of more animated and interactive toys to the kits was suggested. In the infants-toddlers group, mean pain scores were 1.6 ± 2.5 preprocedure, 7.1 ± 3.0 periprocedure, and 2.5 ± 2.5 postprocedure. In the preschoolers group, mean pain scores were 1.6 ± 3.0 preprocedure, 4.8 ± 3.4 periprocedure, and 2.0 ± 3.2 postprocedure. Distraction kits were deemed useful and acceptable by parents and emergency nurses. They are an interesting nonpharmacologic option for nurses to distract children, giving them a sense of control over their pain and improving their hospital experience. Future research should address the feasibility of distraction kits for a broader population of patients and a variety of painful procedures. Copyright © 2017 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
Sznajder, M; Leduc, S; Janvrin, M; Bonnin, M; Aegerter, P; Baudier, F; Chevallier, B; Macarthur, C
2003-01-01
Objectives: Home delivery of counselling and safety devices to prevent child injuries could help parents to adopt safe behaviour. The aim of this study was to test a safety kit designed and used in Quebec (Canada). Design and subjects: One hundred families from four towns in the Paris suburbs were visited at home by nurses or doctors when their child reached 6–9 months. Selection criteria were: primipara, medical problem, psychological, and/or socioeconomic difficulties. Interventions: During the first visit, 50 families (group 1) received counselling and a kit including preventive devices and pamphlets about indoor injuries and ways to avoid them. The other 50 families (group 2) received counselling but not the kit. A second home visit was made 6–8 weeks later. Main outcome measures: The number of safety improvements was calculated 6–8 weeks after a first home visit. Perceived usefulness of the kit was collected from families and from interviewers. Results: Between the first and the second visits, safety improvement was significantly higher in the group with the kit. This was mainly related to the risk of fall (p<0.02), fire and burns (p<0.001), poisoning (p<0.01), and suffocation (p<0.001). For improvement related to devices provided in the kit, the difference between the groups was significant: 64.4% improvement in group 1 versus 41.2% in group 2 (p<0.01). The relative risk (RR) of safety improvement between groups was 1.56 (95% confidence interval (CI) 1.35 to 1.80). Even for improvements not related to the kit the difference remained significant: 31.2% in group 1 versus 20.2% in group 2 (p<0.05); RR = 1.54 (95% CI 1.22 to 1.93). Conclusion: Routine home visits by social services offer a good opportunity to tackle child injury prevention. Free delivery of prevention kits and counselling allow families to modify their behaviour and homes so as to reduce risks. PMID:12966017
76 FR 66994 - Manufacturer of Controlled Substances; Notice of Application
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-28
... following basic classes of controlled substances: Drug Schedule Marihuana (7360) I Cocaine (9041) II The Institute will manufacture marihuana, and cocaine derivatives for use by their customers in analytical kits...
SKYLAB (SL)-4 - POSTLAUNCH - JSC
1973-11-21
S73-37030 (November 1973) --- The procedures for repairing the coolant system aboard the Airlock Module of the Skylab space station in Earth orbit are discussed by flight controllers in the Mission Operations Control Room in the Mission Control Center at Johnson Space Center. Skylab 4 flight director Neil Hutchinson is on the right. Astronaut Russell L. Schweickart is wearing the sports shirt. Astronaut Bruce McCandless II, a Skylab 4 CAPCOM, is seated next to Schweickart. Items of equipment in the foreground are similar to components of a special coolant re-servicing kit which was taken to Earth orbit by the Skylab 4 crewmen. The kit consists of a tank containing 42 pounds of COOLANOL, a series of saddle valves, bolts and spacers, and leak-check hoses. The re-supply tank is a modified command module reaction control subsystem (RCS) fuel tank. Photo credit: NASA
2010-04-01
mouse macrophage nucleofector kit (Program-Y-01) was used. For EL4 cells mouse cell transfection kit (Program-C-09) was used. As controls...direct synergy between immunotherapy and chemotherapy in vitro. We found that pre-treatment of tumor target cells with doxorubicin or paclitaxel...significantly increased cytotoxic effect of T-lymphocytes. Importantly, that effect was antigen-specific, since it was observed only in tumor cells loaded
ERIC Educational Resources Information Center
Dunn, Lloyd M.; Mueller, Max W.
The differential effects of the experimental revision of Level 1 of the Peabody Language Development Kits (PLDK) on the Illinois Test of Psycholinguistic Abilities (ITPA) profiles of disadvantaged first-grade children were studied. Contrasted with 203 control subjects were 529 experimental subjects who received a daily 30-minute oral language…
Biggins, D.E.; Godbey, J.L.; Horton, B.M.; Livieri, T.M.
2011-01-01
Black-footed ferrets (Mustela nigripes) apparently were extirpated from all native habitats by 1987, and their repatriation requires a combination of captive breeding, reintroductions, and translocations among sites. Improvements in survival rates of released ferrets have resulted from experience in quasi-natural environments during their rearing. Reestablishment of a self-sustaining wild population by 1999 provided the 1st opportunity to initiate new populations by translocating wild-born individuals. Using radiotelemetry, we compared behaviors and survival of 18 translocated wild-born ferrets and 18 pen-experienced captive-born ferrets after their release into a prairie dog colony not occupied previously by ferrets. Translocated wild-born ferrets moved significantly less and had significantly higher short-term survival rates than their captive-born counterparts. Using markrecapture methods, we also assessed potential impacts to the established donor population of removing 37% of its estimated annual production of kits. Annual survival rates for 30 ferret kits remaining at the donor subcomplex were higher than rates for 54 ferret kits at the control subcomplex (unmanipulated) for males (+82%) and females (+32%). Minimum survival of translocated kits did not differ significantly from survival of those at the control subcomplex. Direct translocation of young, wild-born ferrets from site to site appears to be an efficient method to establish new populations. ?? 2011 American Society of Mammalogists.
Evaluation of digital PCR for absolute RNA quantification.
Sanders, Rebecca; Mason, Deborah J; Foy, Carole A; Huggett, Jim F
2013-01-01
Gene expression measurements detailing mRNA quantities are widely employed in molecular biology and are increasingly important in diagnostic fields. Reverse transcription (RT), necessary for generating complementary DNA, can be both inefficient and imprecise, but remains a quintessential RNA analysis tool using qPCR. This study developed a Transcriptomic Calibration Material and assessed the RT reaction using digital (d)PCR for RNA measurement. While many studies characterise dPCR capabilities for DNA quantification, less work has been performed investigating similar parameters using RT-dPCR for RNA analysis. RT-dPCR measurement using three, one-step RT-qPCR kits was evaluated using single and multiplex formats when measuring endogenous and synthetic RNAs. The best performing kit was compared to UV quantification and sensitivity and technical reproducibility investigated. Our results demonstrate assay and kit dependent RT-dPCR measurements differed significantly compared to UV quantification. Different values were reported by different kits for each target, despite evaluation of identical samples using the same instrument. RT-dPCR did not display the strong inter-assay agreement previously described when analysing DNA. This study demonstrates that, as with DNA measurement, RT-dPCR is capable of accurate quantification of low copy RNA targets, but the results are both kit and target dependent supporting the need for calibration controls.
Mouse Sperm Cryopreservation and Recovery using the I·Cryo Kit
Liu, Ling; Sansing, Steven R.; Morse, Iva S.; Pritchett-Corning, Kathleen R.
2011-01-01
Thousands of new genetically modified (GM) strains of mice have been created since the advent of transgenesis and knockout technologies. Many of these valuable animals exist only as live animals, with no backup plan in case of emergency. Cryopreservation of embryos can provide this backup, but is costly, can be a lengthy procedure, and generally requires a large number of animals for success. Since the discovery that mouse sperm can be successfully cryopreserved with a basic cryoprotective agent (CPA) consisting of 18% raffinose and 3% skim milk, sperm cryopreservation has become an acceptable and cost-effective procedure for archiving, distributing and recovery of these valuable strains. Here we demonstrate a newly developed I•Cryo kit for mouse sperm cryopreservation. Sperm from five commonly-used strains of inbred mice were frozen using this kit and then recovered. Higher protection ratios of sperm motility (> 60%) and rapid progressive motility (> 45%) compared to the control (basic CPA) were seen for sperm frozen with this kit in 5 inbred mouse strains. Two cell stage embryo development after IVF with the recovered sperm was improved consistently in all 5 mouse strains examined. Over a 1.5 year period, 49 GM mouse lines were archived by sperm cryopreservation with the I•Cryo kit and later recovered by IVF. PMID:22214993
Feng, Hua; Wang, Fang; Wang, Changmiao
2016-07-01
To study the c-Kit expression in the gallbladder of cholesterol lithogenic guinea pig model and the effect of Artemisia capillaris Thunb on interstitial cells of Cajal (ICCs). A total of 45 guinea pigs were randomly assigned into three groups: the control group (guinea pigs fed a standard diet, normal group); the model group (guinea pigs fed a cholesterol gallstone-inducing diet); and the Chinese medicine group (guinea pigs fed the cholesterol gallstone-inducing diet and treated with A. capillaris through intragastric administration, therapy group). Each group had 15 guinea pigs. The gallbladders of the guinea pigs were harvested after 8 weeks. C-Kit expression was detected using an immunohistochemistry staining, real-time PCR, and Western blot analyses. The effect of A. capillaris on ICCs was evaluated by muscle strip contraction experiments. C-Kit expression significantly decreased in the gallbladder of model group, but increased in the Chinese medicine group. The Contractility of guinea pig gallbladder muscle strip significantly improved in the Chinese medicine group. Our results indicated that A. capillaris improves gallbladder impairment by up-regulating c-Kit expression, and it also can improve the contractile response of in vitro guinea pig gallbladder muscle strips.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-10
... classes of controlled substances: Drug Schedule Marihuana (7360) I Cocaine (9041) II The Institute will manufacture marihuana, and cocaine derivatives for use by their customers in analytical kits, reagents, and...
ERIC Educational Resources Information Center
Hausman, Ralph M.; Apffel, James A.
The differential effects of the final revision of Levels 1 and 2 of the Peabody Language Development Kits (PLDK) on the Illinois Test of Psycholinguistic Abilities (ITPA) profiles of young disadvantaged black children were studied. Contrasted with 90 control subjects were 90 experimental subjects who received a daily 30-minute oral language…
Radotinib induces high cytotoxicity in c-KIT positive acute myeloid leukemia cells.
Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk
2017-06-05
Previously, we reported that radotinib, a BCR-ABL1 tyrosine kinase inhibitor, induced cytotoxicity in acute myeloid leukemia (AML) cells. However, the effects of radotinib in the subpopulation of c-KIT-positive AML cells were unclear. We observed that low-concentration radotinib had more potent cytotoxicity in c-KIT-positive cells than c-KIT-negative cells from AML patients. To address this issue, cell lines with high c-KIT expression, HEL92.1.7, and moderate c-KIT expression, H209, were selected. HEL92.1.7 cells were grouped into intermediate and high c-KIT expression populations. The cytotoxicity of radotinib against the HEL92.1.7 cell population with intermediate c-KIT expression was not different from that of the population with high c-KIT expression. When H209 cells were grouped into c-KIT expression-negative and c-KIT expression-positive populations, radotinib induced cytotoxicity in the c-KIT-positive population, but not the c-KIT-negative population. Thus, radotinib induces cytotoxicity in c-KIT-positive cells, regardless of the c-KIT expression intensity. Therefore, radotinib induces significant cytotoxicity in c-KIT-positive AML cells, suggesting that radotinib is a potential target agent for the treatment of c-KIT-positive malignancies including AML. Copyright © 2017 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-16
... under Export Control Classification Number (``ECCN'') 0A982, controlled for Crime Control reasons, and..., classified under ECCN 0A982, controlled for Crime Control reasons, and valued at approximately $112, from the... kit, items classified under ECCN 0A982, controlled for Crime Control reasons, and valued at...
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Run-on/run-off control systems. 258.26 Section 258.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Operating Criteria § 258.26 Run-on/run-off control systems. (a...
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Run-on/run-off control systems. 258.26 Section 258.26 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Operating Criteria § 258.26 Run-on/run-off control systems. (a...
Techni-kits and Techni-kit Building Systems
NASA Technical Reports Server (NTRS)
Callender, E. D.; Hartsough, C.; Morris, R. V.; Yamamoto, Y.
1985-01-01
Techni-kits consists of theories, methods, standards and computer based tools that assist in design of information-intensive systems. Techni-kit "building system" is techni-kit that builds techni-kits.
Chao, Ming-Yu; Liu, Kung-Tien; Hsia, Yi-Chih; Liao, Mei-Hsiu; Shen, Lie-Hang
2011-01-01
Technetium-99m ethyl cysteinate dimer (Tc-99m-ECD) is an essential imaging agent used in evaluating the regional cerebral blood flow in patients with cerebrovascular diseases. Determination of active pharmaceutical ingredient, that is, L-Cysteine, N, N′-1,2-ethanediylbis-, diethyl ester, dihydrochloride (ECD) in ECD Kit is a relevant requirement for the pharmaceutical quality control in processes of mass fabrication. We here presented a direct solid sample determination method of ECD in ECD Kit without sample dissolution to avoid the rapid degradation of ECD. An elemental analyzer equipped with a nondispersive infrared detector and a calibration curve of coal standard was used for the quantitation of sulfur in ECD Kit. No significant matrix effect was found. The peak area of coal standard against the amount of sulfur was linear over the range of 0.03–0.10 mg, with a correlation coefficient (r) of 0.9993. Method validation parameters were achieved to demonstrate the potential of this method. PMID:21687539
Analysis of Platelet-Rich Plasma Extraction
Fitzpatrick, Jane; Bulsara, Max K.; McCrory, Paul Robert; Richardson, Martin D.; Zheng, Ming Hao
2017-01-01
Background: Platelet-rich plasma (PRP) has been extensively used as a treatment in tissue healing in tendinopathy, muscle injury, and osteoarthritis. However, there is variation in methods of extraction, and this produces different types of PRP. Purpose: To determine the composition of PRP obtained from 4 commercial separation kits, which would allow assessment of current classification systems used in cross-study comparisons. Study Design: Controlled laboratory study. Methods: Three normal adults each donated 181 mL of whole blood, some of which served as a control and the remainder of which was processed through 4 PRP separation kits: GPS III (Biomet Biologics), Smart-Prep2 (Harvest Terumo), Magellan (Arteriocyte Medical Systems), and ACP (Device Technologies). The resultant PRP was tested for platelet count, red blood cell count, and white blood cell count, including differential in a commercial pathology laboratory. Glucose and pH measurements were obtained from a blood gas autoanalyzer machine. Results: Three kits taking samples from the “buffy coat layer” were found to have greater concentrations of platelets (3-6 times baseline), while 1 kit taking samples from plasma was found to have platelet concentrations of only 1.5 times baseline. The same 3 kits produced an increased concentration of white blood cells (3-6 times baseline); these consisted of neutrophils, leukocytes, and monocytes. This represents high concentrations of platelets and white blood cells. A small drop in pH was thought to relate to the citrate used in the sample preparation. Interestingly, an unexpected increase in glucose concentrations, with 3 to 6 times greater than baseline levels, was found in all samples. Conclusion: This study reveals the variation of blood components, including platelets, red blood cells, leukocytes, pH, and glucose in PRP extractions. The high concentrations of cells are important, as the white blood cell count in PRP samples has frequently been ignored, being considered insignificant. The lack of standardization of PRP preparation for clinical use has contributed at least in part to the varying clinical efficacy in PRP use. Clinical Relevance: The variation of platelet and other blood component concentrations between commercial PRP kits may affect clinical treatment outcomes. There is a need for standardization of PRP for clinical use. PMID:28210651
Fontanesi, Luca; Vargiolu, Manuela; Scotti, Emilio; Latorre, Rocco; Faussone Pellegrini, Maria Simonetta; Mazzoni, Maurizio; Asti, Martina; Chiocchetti, Roberto; Romeo, Giovanni; Clavenzani, Paolo; De Giorgio, Roberto
2014-01-01
The English spotting coat color locus in rabbits, also known as Dominant white spotting locus, is determined by an incompletely dominant allele (En). Rabbits homozygous for the recessive wild-type allele (en/en) are self-colored, heterozygous En/en rabbits are normally spotted, and homozygous En/En animals are almost completely white. Compared to vital en/en and En/en rabbits, En/En animals are subvital because of a dilated ("mega") cecum and ascending colon. In this study, we investigated the role of the KIT gene as a candidate for the English spotting locus in Checkered Giant rabbits and characterized the abnormalities affecting enteric neurons and c-kit positive interstitial cells of Cajal (ICC) in the megacolon of En/En rabbits. Twenty-one litters were obtained by crossing three Checkered Giant bucks (En/en) with nine Checkered Giant (En/en) and two en/en does, producing a total of 138 F1 and backcrossed rabbits. Resequencing all coding exons and portions of non-coding regions of the KIT gene in 28 rabbits of different breeds identified 98 polymorphisms. A single nucleotide polymorphism genotyped in all F1 families showed complete cosegregation with the English spotting coat color phenotype (θ=0.00 LOD =75.56). KIT gene expression in cecum and colon specimens of En/En (pathological) rabbits was 5-10% of that of en/en (control) rabbits. En/En rabbits showed reduced and altered c-kit immunolabelled ICC compared to en/en controls. Morphometric data on whole mounts of the ascending colon showed a significant decrease of HuC/D (P<0.05) and substance P (P<0.01) immunoreactive neurons in En/En vs. en/en. Electron microscopy analysis showed neuronal and ICC abnormalities in En/En tissues. The En/En rabbit model shows neuro-ICC changes reminiscent of the human non-aganglionic megacolon. This rabbit model may provide a better understanding of the molecular abnormalities underlying conditions associated with non-aganglionic megacolon.
Fontanesi, Luca; Vargiolu, Manuela; Scotti, Emilio; Latorre, Rocco; Faussone Pellegrini, Maria Simonetta; Mazzoni, Maurizio; Asti, Martina; Chiocchetti, Roberto; Romeo, Giovanni; Clavenzani, Paolo; De Giorgio, Roberto
2014-01-01
The English spotting coat color locus in rabbits, also known as Dominant white spotting locus, is determined by an incompletely dominant allele (En). Rabbits homozygous for the recessive wild-type allele (en/en) are self-colored, heterozygous En/en rabbits are normally spotted, and homozygous En/En animals are almost completely white. Compared to vital en/en and En/en rabbits, En/En animals are subvital because of a dilated (“mega”) cecum and ascending colon. In this study, we investigated the role of the KIT gene as a candidate for the English spotting locus in Checkered Giant rabbits and characterized the abnormalities affecting enteric neurons and c-kit positive interstitial cells of Cajal (ICC) in the megacolon of En/En rabbits. Twenty-one litters were obtained by crossing three Checkered Giant bucks (En/en) with nine Checkered Giant (En/en) and two en/en does, producing a total of 138 F1 and backcrossed rabbits. Resequencing all coding exons and portions of non-coding regions of the KIT gene in 28 rabbits of different breeds identified 98 polymorphisms. A single nucleotide polymorphism genotyped in all F1 families showed complete cosegregation with the English spotting coat color phenotype (θ = 0.00 LOD = 75.56). KIT gene expression in cecum and colon specimens of En/En (pathological) rabbits was 5–10% of that of en/en (control) rabbits. En/En rabbits showed reduced and altered c-kit immunolabelled ICC compared to en/en controls. Morphometric data on whole mounts of the ascending colon showed a significant decrease of HuC/D (P<0.05) and substance P (P<0.01) immunoreactive neurons in En/En vs. en/en. Electron microscopy analysis showed neuronal and ICC abnormalities in En/En tissues. The En/En rabbit model shows neuro-ICC changes reminiscent of the human non-aganglionic megacolon. This rabbit model may provide a better understanding of the molecular abnormalities underlying conditions associated with non-aganglionic megacolon. PMID:24736498
Emergency cricothyrotomy in confined space airway emergencies: a comparison.
Givens, Gregory C; Shelton, Stephen L; Brown, Eric A
2011-08-01
In confined-space airway emergencies, prehospital personnel may need to perform cricothyrotomy when conventional airway techniques cannot be utilized or have failed. This study is a prospective, cross-over, randomized controlled trial that compares two widely-known techniques using two commercially available kits. Twenty residents at Palmetto Health Richland Department of Emergency Medicine participated in the study. Their performance was assessed using the time required to placement and correctness of placement for each device. The residents performed the procedures on an Air-Man™ manikin that had been situated in a confined space.The residents also indicated which kit they would prefer in a confined-space, emergency airway situation. All of the devices were placed in the airway. The mean time to placement for the Melker™ and Quicktrach™ kits was 108.5 seconds and 23.9 seconds, respectively. This yielded a mean difference of 84.5 seconds, which provided a t-statistic of 8.88 (p < 0.0001).There was no evidence of a carry-over effect (p = 0.292) or a period effect (p = 0.973). All residents preferred using the Quicktrach™ kit. Use of the Quicktrach™ kit resulted in the fastest time to placement, was placed correctly in the airway, and was preferred by each of the residents. Its small, simple,and sturdy design, with few parts and easy manipulation, allow the Quicktrach™ to be a valuable option in prehospital situations involving confined spaces. The Melker™ kit, with its many parts, and need for greater manipulation, is not as easily utilized or preferred in a confined space scenario.
The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-Rotors
NASA Technical Reports Server (NTRS)
Scott, Rollin L.
2014-01-01
During the course of the Kennedy Space Center Summer Internship, two main experiments were performed: The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-copters. The objectives of the Vacuum-Compacted Regolith Gripping Mechanism, often abbreviated as the Granular Gripper, are to exhibit Space Technology, such as a soft robotic hand, lift different apparatuses used to excavate regolith, and conserve energy while executing its intended task. The project is being conducted to test how much weight the Granular Gripper can hold. With the use of an Animatronic Robotic Hand, Arduino Uno, and other components, the system was calibrated before actually conducting the intended weight test. The maximum weight each finger could hold with the servos running, in the order of pinky, ring, middle, and index fingers, are as follows: 1.340N, 1.456 N, 0.9579 N, and 1.358 N. Using the small vacuum pump system, the maximum weight each finger could hold, in the same order, was: 4.076 N, 6.159 N, 5.454 N, and 4.052 N. The maximum torques on each of the fingers when the servos were running, in the same respective order, was: 0.0777 Nm, 0.0533 Nm, 0.0648 Nm, and 0.0532 Nm. The maximum torques on the individual fingers, when the small vacuum pump was in effect, in the same order as above, was: 0.2318 Nm, 0.3032 Nm, 0.2741 Nm, and 0.1618 Nm. In testing all the fingers with the servos running, the total weight was 5.112 N and the maximum torque on the all the fingers was 0.2515 Nm. However, when the small vacuum pump system was used, the total weight was 19.741 N and the maximum torque on the all the fingers was 0.9713 Nm. The conclusion that was drawn stated that using the small vacuum pump system proved nearly 4 times more effective when testing how much weigh the hand could hold. The resistance provided by the compacted sand in the glove allowed more weight to be held by the hand and glove. Also, when the servos turned off and the hand still retaining its position, energy is being saved because the vacuum created the same resistance the running servos did without using power. The Unmanned Flights via Quad-rotors are built because multi-rotor dynamics are an important starting point and fair analog for space craft control systems and they make good terrestrial development platforms for various aspects of control for space crafts. The project is being conducted to see what the thrust response is going to be when a pulse width modulation command is sent to the control system since the quad-rotors are PWM controlled. A simulation environment in constructed so that one can quickly iterate and test different designs such as control systems, PID control vs. LDR control, and state estimation. Using two DIY Quad Kits, APM 2.6, testing apparatus (called a data acquisition system) to test the quad-rotors, and a simulation program such as Simulink, two quad-rotors are built and controlled via a simulation program, which is designed to be as realistic as possible and not idealistic. Due to the quad-rotors not being completely built nor ready for testing, there are no results or conclusions to report.
Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto
2017-10-01
Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.
Denis, B; Broc, G; Sauleau, E A; Gendre, I; Gana, K; Perrin, P
2017-02-01
Despite the involvement of general practitioners, the mailing of several recall letters and of the faecal occult blood test (FOBT) kit, the uptake remains insufficient in the French colorectal cancer-screening programme. Some studies have demonstrated a greater efficacy of tailored telephone counselling over usual care, untailored invitation mailing and FOBT kit mailing. We evaluated the feasibility and the effectiveness of telephone counselling on participation in the population-based FOBT colorectal cancer-screening programme implemented in Alsace (France). Underusers were randomized into a control group with untailored invitation and FOBT kit mailing (n=19,756) and two intervention groups for either a computer-assisted telephone interview (n=9367), system for tailored promotion of colorectal cancer screening, or a telephone-based motivational interview (n=9374). Only 5691 (19.9%) people were actually counseled, so that there was no difference in participation between the intervention groups taken together (13.9%, 95% confidence interval [CI] [13.5-14.4]) and the control group (13.9%, 95% CI [13.4-14.4]) (P=1.0) in intent-to-treat analysis. However, in per-protocol analysis, participation was significantly higher in the two intervention groups than in the control group (12.9%, 95% CI [12.6-13.2]) (P<0.01), with no difference between computer-assisted telephone interview (24.6%, 95% CI [22.7-26.4]) and motivational interview (23.6%, 95% CI [21.8-25.4]) (P=0.44). There was no difference of effectiveness between tailored telephone counselling and untailored invitation and FOBT kit mailing on participation of underusers in an organized population-based colorectal cancer screening programme. A greater efficacy of telephone counselling, around twice that of invitation and FOBT kit mailing, was observed only in people who could actually be counseled, without difference between computer-assisted telephone interview and motivational interview. However, technical failures hampered telephone counselling, so that there was no difference in intent-to-treat analysis. The rate of technical success of telephone interviews should be evaluated, and enhanced if insufficient, before implementation of telephone counselling in population-based cancer screening programmes. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Obata, Y; Horikawa, K; Takahashi, T; Akieda, Y; Tsujimoto, M; Fletcher, J A; Esumi, H; Nishida, T; Abe, R
2017-01-01
Gastrointestinal stromal tumors (GISTs) are caused by gain-of-function mutations in the Kit receptor tyrosine kinase. Most primary GIST patients respond to the Kit inhibitor imatinib, but this drug often becomes ineffective because of secondary mutations in the Kit kinase domain. The characteristic intracellular accumulation of imatinib-sensitive and -resistant Kit protein is well documented, but its relationship to oncogenic signaling remains unknown. Here, we show that in cancer tissue from primary GIST patients as well as in cell lines, mutant Kit accumulates on the Golgi apparatus, whereas normal Kit localizes to the plasma membrane (PM). In imatinib-resistant GIST with a secondary Kit mutation, Kit localizes predominantly on the Golgi apparatus. Both imatinib-sensitive and imatinib-resistant Kit (Kit(mut)) become fully auto-phosphorylated only on the Golgi and only if in a complex-glycosylated form. Kit(mut) accumulates on the Golgi during the early secretory pathway, but not after endocytosis. The aberrant kinase activity of Kit(mut) prevents its export from the Golgi to the PM. Furthermore, Kit(mut) on the Golgi signals and activates the phosphatidylinositol 3-kinase–Akt (PI3K–Akt) pathway, signal transducer and activator of transcription 5 (STAT5), and the Mek–Erk pathway. Blocking the biosynthetic transport of Kit(mut) to the Golgi from the endoplasmic reticulum inhibits oncogenic signaling. PM localization of Kit(mut) is not required for its signaling. Activation of Src-family tyrosine kinases on the Golgi is essential for oncogenic Kit signaling. These results suggest that the Golgi apparatus serves as a platform for oncogenic Kit signaling. Our study demonstrates that Kit(mut)’s pathogenicity is related to its mis-localization, and may offer a new strategy for treating imatinib-resistant GISTs. PMID:28192400
Protein kinase C-δ-mediated recycling of active KIT in colon cancer.
Park, Misun; Kim, Won Kyu; Song, Meiying; Park, Minhee; Kim, Hyunki; Nam, Hye Jin; Baek, Sung Hee; Kim, Hoguen
2013-09-15
Abnormal signaling through receptor tyrosine kinase (RTK) moieties is important in tumorigenesis and drug targeting of colorectal cancers. Wild-type KIT (WT-KIT), a RTK that is activated upon binding with stem cell factor (SCF), is highly expressed in some colon cancers; however, little is known about the functional role of SCF-dependent KIT activation in colon cancer pathogenesis. We aimed to elucidate the conditions and roles of WT-KIT activation in colon cancer tumorigenesis. Colorectal cancers with KIT expression were characterized by immunoblotting and immunohistochemistry. The biologic alterations after KIT-SCF binding were analyzed with or without protein kinase C (PKC) activation. We found that WT-KIT was expressed in a subset of colon cancer cell lines and was activated by SCF, leading to activation of downstream AKT and extracellular signal-regulated kinase (ERK) signaling pathways. We also showed that KIT expression gradually decreased, after prolonged SCF stimulation, due to lysosomal degradation. Degradation of WT-KIT after SCF binding was significantly rescued when PKC was activated. We also showed the involvement of activated PKC-δ in the recycling of WT-KIT. We further showed that a subset of colorectal cancers exhibit expressions of both WT-KIT and activated PKC-δ and that expression of KIT is correlated with poor patient survival (P = 0.004). Continuous downstream signal activation after KIT-SCF binding is accomplished through PKC-δ-mediated recycling of KIT. This sustained KIT activation may contribute to tumor progression in a subset of colon cancers with KIT expression and might provide the rationale for a therapeutic approach targeting KIT. ©2013 AACR.
3D vision upgrade kit for TALON robot
NASA Astrophysics Data System (ADS)
Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Pezzaniti, J. Larry; Chenault, David B.; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Pettijohn, Brad
2010-04-01
In this paper, we report on the development of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. The 3D vision system was integrated onto a TALON IV Robot and Operator Control Unit (OCU) such that stock components could be electrically disconnected and removed, and upgrade components coupled directly to the mounting and electrical connections. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.
Serpi, Raisa; Tolonen, Anna‐Maria; Tenhunen, Olli; Pieviläinen, Oskari; Kubin, Anna‐Maria; Vaskivuo, Tommi; Soini, Ylermi; Kerkelä, Risto; Leskinen, Hanna; Ruskoaho, Heikki
2009-01-01
Abstract There is strong evidence for the use of angiotensin converting enzyme inhibitors and beta‐blockers to reduce morbidity and mortality in patients with myocardial infarction (MI), whereas the effect of angiotensin receptor blockers is less clear. We evaluated the effects of an angiotensin receptor blocker losartan and a beta‐blocker metoprolol on left ventricular (LV) remodeling, c‐kit+ cells, proliferation, fibrosis, apoptosis, and angiogenesis using a model of coronary ligation in rats. Metoprolol treatment for 2 weeks improved LV systolic function. In contrast, losartan triggered deleterious structural remodeling and functional deterioration of LV systolic function, ejection fraction being 41% and fractional shortening 47% lower in losartan group than in controls 2 weeks after MI. The number of c‐kit+ cells as well as expression of Ki‐67 was increased by metoprolol. Losartan‐induced thinning of the anterior wall and ventricular dilation were associated with increased apoptosis and fibrosis, while losartan had no effect on the expression of c‐kit or Ki‐67. Metoprolol or losartan had no effect on microvessel density. These results demonstrate that beta‐blocker treatment attenuated adverse remodeling via c‐kit+ cells and proliferation, whereas angiotensin receptor blocker‐induced worsening of LV systolic function was associated with increased apoptosis and fibrosis in the peri‐infarct region. PMID:20443934
The Qiagen Investigator® Quantiplex HYres as an alternative kit for DNA quantification.
Frégeau, Chantal J; Laurin, Nancy
2015-05-01
The Investigator® Quantiplex HYres kit was evaluated as a potential replacement for dual DNA quantification of casework samples. This kit was determined to be highly sensitive with a limit of quantification and limit of detection of 0.0049ng/μL and 0.0003ng/μL, respectively, for both human and male DNA, using full or half reaction volumes. It was also accurate in assessing the amount of male DNA present in 96 mock and actual casework male:female mixtures (various ratios) processed in this exercise. The close correlation between the male/human DNA ratios expressed in percentages derived from the Investigator® Quantiplex HYres quantification results and the male DNA proportion calculated in mixed AmpFlSTR® Profiler® Plus or AmpFlSTR® Identifiler® Plus profiles, using the Amelogenin Y peak and STR loci, allowed guidelines to be developed to facilitate decisions regarding when to submit samples to Y-STR rather than autosomal STR profiling. The internal control (IC) target was shown to be more sensitive to inhibitors compared to the human and male DNA targets included in the Investigator® Quantiplex HYres kit serving as a good quality assessor of DNA extracts. The new kit met our criteria of enhanced sensitivity, accuracy, consistency, reliability and robustness for casework DNA quantification. Crown Copyright © 2015. Published by Elsevier Ireland Ltd. All rights reserved.
Cardiac c-Kit Biology Revealed by Inducible Transgenesis.
Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A
2018-06-22
Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart, upregulating c-Kit expression in response to pathological stress. c-Kit myocardial biology is more complex and varied than previously appreciated or documented, demonstrating validity in multiple points of coexisting yet heretofore seemingly irreconcilable published findings. © 2018 American Heart Association, Inc.
[Comparison of Dengue viral nonstructural protein 1 antigen testing kits].
Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F
2018-02-06
Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.
Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A
2008-01-01
To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.
Evaluation of the kinase domain of c-KIT in canine cutaneous mast cell tumors
Webster, Joshua D; Kiupel, Matti; Yuzbasiyan-Gurkan, Vilma
2006-01-01
Background Mutations in the c-KIT proto-oncogene have been implicated in the progression of several neoplastic diseases, including gastrointestinal stromal tumors and mastocytosis in humans, and cutaneous mast cell tumors (MCTs) in canines. Mutations in human mastocytosis patients primarily occur in c-KIT exon 17, which encodes a portion of its kinase domain. In contrast, deletions and internal tandem duplication (ITD) mutations are found in the juxtamembrane domain of c-KIT in approximately 15% of canine MCTs. In addition, ITD c-KIT mutations are significantly associated with aberrant KIT protein localization in canine MCTs. However, some canine MCTs have aberrant KIT localization but lack ITD c-KIT mutations, suggesting that other mutations or other factors may be responsible for aberrant KIT localization in these tumors. Methods In order to characterize the prevalence of mutations in the phospho-transferase portion of c-KIT's kinase domain in canine MCTs exons 16–20 of 33 canine MCTs from 33 dogs were amplified and sequenced. Additionally, in order to determine if mutations in c-KIT exon 17 are responsible for aberrant KIT localization in MCTs that lack juxtamembrane domain c-KIT mutations, c-KIT exon 17 was amplified and sequenced from 18 canine MCTs that showed an aberrant KIT localization pattern but did not have ITD c-KIT mutations. Results No mutations or polymorphisms were identified in exons 16–20 of any of the MCTs examined. Conclusion In conclusion, mutations in the phospho-transferase portion of c-KIT's kinase domain do not play an important role in the progression of canine cutaneous MCTs, or in the aberrant localization of KIT in canine MCTs. PMID:16579858
Vicinanza, Carla; Aquila, Iolanda; Scalise, Mariangela; Cristiano, Francesca; Marino, Fabiola; Cianflone, Eleonora; Mancuso, Teresa; Marotta, Pina; Sacco, Walter; Lewis, Fiona C; Couch, Liam; Shone, Victoria; Gritti, Giulia; Torella, Annalaura; Smith, Andrew J; Terracciano, Cesare Mn; Britti, Domenico; Veltri, Pierangelo; Indolfi, Ciro; Nadal-Ginard, Bernardo; Ellison-Hughes, Georgina M; Torella, Daniele
2017-12-01
Multipotent adult resident cardiac stem cells (CSCs) were first identified by the expression of c-kit, the stem cell factor receptor. However, in the adult myocardium c-kit alone cannot distinguish CSCs from other c-kit-expressing (c-kit pos ) cells. The adult heart indeed contains a heterogeneous mixture of c-kit pos cells, mainly composed of mast and endothelial/progenitor cells. This heterogeneity of cardiac c-kit pos cells has generated confusion and controversy about the existence and role of CSCs in the adult heart. Here, to unravel CSC identity within the heterogeneous c-kit-expressing cardiac cell population, c-kit pos cardiac cells were separated through CD45-positive or -negative sorting followed by c-kit pos sorting. The blood/endothelial lineage-committed (Lineage pos ) CD45 pos c-kit pos cardiac cells were compared to CD45 neg (Lineage neg /Lin neg ) c-kit pos cardiac cells for stemness and myogenic properties in vitro and in vivo. The majority (~90%) of the resident c-kit pos cardiac cells are blood/endothelial lineage-committed CD45 pos CD31 pos c-kit pos cells. In contrast, the Lin neg CD45 neg c-kit pos cardiac cell cohort, which represents ⩽10% of the total c-kit pos cells, contain all the cardiac cells with the properties of adult multipotent CSCs. These characteristics are absent from the c-kit neg and the blood/endothelial lineage-committed c-kit pos cardiac cells. Single Lin neg c-kit pos cell-derived clones, which represent only 1-2% of total c-kit pos myocardial cells, when stimulated with TGF-β/Wnt molecules, acquire full transcriptome and protein expression, sarcomere organisation, spontaneous contraction and electrophysiological properties of differentiated cardiomyocytes (CMs). Genetically tagged cloned progeny of one Lin neg c-kit pos cell when injected into the infarcted myocardium, results in significant regeneration of new CMs, arterioles and capillaries, derived from the injected cells. The CSC's myogenic regenerative capacity is dependent on commitment to the CM lineage through activation of the SMAD2 pathway. Such regeneration was not apparent when blood/endothelial lineage-committed c-kit pos cardiac cells were injected. Thus, among the cardiac c-kit pos cell cohort only a very small fraction has the phenotype and the differentiation/regenerative potential characteristics of true multipotent CSCs.
Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.
Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H
2017-12-12
Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.
Validation of Mission Plans Through Simulation
NASA Astrophysics Data System (ADS)
St-Pierre, J.; Melanson, P.; Brunet, C.; Crabtree, D.
2002-01-01
The purpose of a spacecraft mission planning system is to automatically generate safe and optimized mission plans for a single spacecraft, or more functioning in unison. The system verifies user input syntax, conformance to commanding constraints, absence of duty cycle violations, timing conflicts, state conflicts, etc. Present day constraint-based systems with state-based predictive models use verification rules derived from expert knowledge. A familiar solution found in Mission Operations Centers, is to complement the planning system with a high fidelity spacecraft simulator. Often a dedicated workstation, the simulator is frequently used for operator training and procedure validation, and may be interfaced to actual control stations with command and telemetry links. While there are distinct advantages to having a planning system offer realistic operator training using the actual flight control console, physical verification of data transfer across layers and procedure validation, experience has revealed some drawbacks and inefficiencies in ground segment operations: With these considerations, two simulation-based mission plan validation projects are under way at the Canadian Space Agency (CSA): RVMP and ViSION. The tools proposed in these projects will automatically run scenarios and provide execution reports to operations planning personnel, prior to actual command upload. This can provide an important safeguard for system or human errors that can only be detected with high fidelity, interdependent spacecraft models running concurrently. The core element common to these projects is a spacecraft simulator, built with off-the- shelf components such as CAE's Real-Time Object-Based Simulation Environment (ROSE) technology, MathWork's MATLAB/Simulink, and Analytical Graphics' Satellite Tool Kit (STK). To complement these tools, additional components were developed, such as an emulated Spacecraft Test and Operations Language (STOL) interpreter and CCSDS TM/TC encoders and decoders. This paper discusses the use of simulation in the context of space mission planning, describes the projects under way and proposes additional venues of investigation and development.
NASA Astrophysics Data System (ADS)
Alessio, F.; Barandela, M. C.; Callot, O.; Duval, P.-Y.; Franek, B.; Frank, M.; Galli, D.; Gaspar, C.; Herwijnen, E. v.; Jacobsson, R.; Jost, B.; Neufeld, N.; Sambade, A.; Schwemmer, R.; Somogyi, P.
2010-04-01
LHCb has designed and implemented an integrated Experiment Control System. The Control System uses the same concepts and the same tools to control and monitor all parts of the experiment: the Data Acquisition System, the Timing and the Trigger Systems, the High Level Trigger Farm, the Detector Control System, the Experiment's Infrastructure and the interaction with the CERN Technical Services and the Accelerator. LHCb's Run Control, the main interface used by the experiment's operator, provides access in a hierarchical, coherent and homogeneous manner to all areas of the experiment and to all its sub-detectors. It allows for automated (or manual) configuration and control, including error recovery, of the full experiment in its different running modes. Different instances of the same Run Control interface are used by the various sub-detectors for their stand-alone activities: test runs, calibration runs, etc. The architecture and the tools used to build the control system, the guidelines and components provided to the developers, as well as the first experience with the usage of the Run Control will be presented
2004-10-01
using flow cytometry after staining with CBA kit produced by BD-Pharmingen. The CBA kit can simultaneously test 5 inflammatory cytokines that include...or TLR4 transfected cells using flow cytometry . CHOK1 and CHOR1.1 cells were plated out in a 24-well dish and transfected 24 h later with either TLR2...with PE-labeled anti-hTLR2 antibody or PE-isotype control antibody (eBiosciences, CA), and cells were analyzed by flow cytometry . 39 The expression
Modulating Leukemia-Initiating Cell Quiescence to Improve Leukemia Treatment
2015-09-01
T- cells and in innate immunity (Lacorazza et al., 2002). It controls the proliferation and homing of CD8+ T- cells via the Kruppel-like factors...Lin2Sca12IL7R2Kit1FccRII/ IIIhighCD34high), megakaryocyte-erythroid progenitor cell (MEP) (Lin2Sca12IL7R2Kit1FccRII/IIIlowCD34low), and common lymphoid ...to this model, the first wave gives rise exclusively to innate immune B cells in early embryonic life and may be derived from progenitor cells
Receptor tyrosine kinase (c-Kit) inhibitors: a potential therapeutic target in cancer cells
Abbaspour Babaei, Maryam; Kamalidehghan, Behnam; Saleem, Mohammad; Huri, Hasniza Zaman; Ahmadipour, Fatemeh
2016-01-01
c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit for future cancer therapy. In addition, it has c-Kit inhibitor drug properties and their functions have been listed in tables and demonstrated in schematic pictures. This review also has collected previous studies that targeted c-Kit as a novel strategy for cancer therapy. This paper further emphasizes the advantages of this approach, as well as the limitations that must be addressed in the future. Finally, although c-Kit is an attractive target for cancer therapy, based on the outcomes of treatment of patients with c-Kit inhibitors, it is unlikely that Kit inhibitors alone can lead to cure. It seems that c-Kit mutations alone are not sufficient for tumorogenesis, but do play a crucial role in cancer occurrence. PMID:27536065
EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations
NASA Technical Reports Server (NTRS)
Rucker, Michelle A.; Hood, Drew; Walker, Mary; Venkateswaran, Kasthuri J.; Schuerger, Andrew C.
2018-01-01
When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.
Seward, Nadine; Prost, Audrey; Copas, Andrew; Corbin, Marine; Li, Leah; Colbourn, Tim; Osrin, David; Neuman, Melissa; Azad, Kishwar; Kuddus, Abdul; Nair, Nirmala; Tripathy, Prasanta; Manandhar, Dharma; Costello, Anthony; Cortina-Borja, Mario
2015-01-01
Background Globally, puerperal sepsis accounts for an estimated 8–12% of maternal deaths, but evidence is lacking on the extent to which clean delivery practices could improve maternal survival. We used data from the control arms of four cluster-randomised controlled trials conducted in rural India, Bangladesh and Nepal, to examine associations between clean delivery kit use and hand washing by the birth attendant with maternal mortality among home deliveries. Methods We tested associations between clean delivery practices and maternal deaths, using a pooled dataset for 40,602 home births across sites in the three countries. Cross-sectional data were analysed by fitting logistic regression models with and without multiple imputation, and confounders were selected a priori using causal directed acyclic graphs. The robustness of estimates was investigated through sensitivity analyses. Results Hand washing was associated with a 49% reduction in the odds of maternal mortality after adjusting for confounding factors (adjusted odds ratio (AOR) 0.51, 95% CI 0.28–0.93). The sensitivity analysis testing the missing at random assumption for the multiple imputation, as well as the sensitivity analysis accounting for possible misclassification bias in the use of clean delivery practices, indicated that the association between hand washing and maternal death had been over estimated. Clean delivery kit use was not associated with a maternal death (AOR 1.26, 95% CI 0.62–2.56). Conclusions Our evidence suggests that hand washing in delivery is critical for maternal survival among home deliveries in rural South Asia, although the exact magnitude of this effect is uncertain due to inherent biases associated with observational data from low resource settings. Our findings indicating kit use does not improve maternal survival, suggests that the soap is not being used in all instances that kit use is being reported. PMID:26295838
Nishi, N; Osawa, M; Ishikawa, R; Nishikawa, M; Tsumura, H; Inoue, H; Sudo, T
1995-09-01
It is known that treatment of mice with 5-fluorouracil (5-FU, 150 mg/kg) confers radioprotection. To investigate this effect, we performed bone marrow transplantation (BMT) using C57BL/6-Ly5 congenic mice treated with 5-FU five days prior to experiments. The mononuclear cells (MNC) in 5-FU-treated bone marrow (BM) were 10 times more radioprotective than those in untreated BM. Moreover, the number of BM MNC expressing c-kit on their surface from 5-FU-treated mice was markedly decreased relative to those from untreated controls. These results showed that the surface characteristics of cells that contributed to this radio-protective effect differ from those of stem cells as reported recently. BM MNC of mice treated with 5-FU were separated on the basis of expression of the lineage-specific antigens (Lin), c-kit, and Ly6A/E. When injected into lethally irradiated mice, 1,000 Lin+ and Lin-c-kit+Ly6A/E+ cells showed radioprotective effects such that 100% and 60% survived, respectively. Flow cytometric analysis 165 days after BMT showed that 88.8% and 65.1% of peripheral blood (PB) in mice transplanted with Lin+ and Lin-c-kit+Ly6A/E+ was derived from donor mice, respectively. After six months, donor-derived Lin-c-kit+Ly6A/E+ cells which showed radioprotective effects on a secondary irradiated host were detected from mice transplanted with Lin+ cells from 5-FU-treated mice. Taken together, these findings demonstrated that stem cells expressing Lin+ present in the BM of mice treated with 5-FU other than Lin-c-kit+Ly6A/E+ cells and these Lin+ cells play an important role in the recovery of myeloablative mice.
Gaudin, Valérie; Rault, Annie; Hedou, Celine; Soumet, Christophe; Verdon, Eric
2017-09-01
Efficient screening methods are needed to control antibiotic residues in eggs. A microbiological kit (Explorer® 2.0 test (Zeu Inmunotech, Spain)) and an immunobiosensor kit (Microarray II (AM® II) on Evidence Investigator™ system (Randox, UK)) have been evaluated and validated for screening of antibiotic residues in eggs, according to the European decision EC/2002/657 and to the European guideline for the validation of screening methods. The e-reader™ system, a new automatic incubator/reading system, was coupled to the Explorer 2.0 test. The AM II kit can detect residues of six different families of antibiotics in different matrices including eggs. For both tests, a different liquid/liquid extraction of eggs had to be developed. Specificities of the Explorer 2.0 and AM II kit were equal to 8% and 0% respectively. The detection capabilities were determined for 19 antibiotics, with representatives from different families, for Explorer 2.0 and 12 antibiotics for the AM II kit. For the nine antibiotics having a maximum residue limit (MRL) in eggs, the detection capabilities CCβ of Explorer 2.0 were below the MRL for four antibiotics, equal to the MRL for two antibiotics and between 1 and 1.5 MRLs for the three remaining antibiotics (tetracyclines). For the antibiotics from other families, the detection capabilities were low for beta-lactams and sulfonamides and satisfactory for dihydrostreptomycin (DHS) and fluoroquinolones, which are usually difficult to detect with microbiological tests. The CCβ values of the AM II kit were much lower than the respective MRLs for three detected antibiotics (tetracycline, oxytetracycline, tylosin). Concerning the nine other antibiotics, the detection capabilities determined were low. The highest CCβ was obtained for streptomycin (100 µg kg -1 ).
Kozlowski, Maya; Larose, Louise; Lee, Fai; Le, Duc Mingh; Rottapel, Robert; Siminovitch, Katherine A.
1998-01-01
The SH2 domain-containing SHP-1 tyrosine phosphatase has been shown to negatively regulate a broad spectrum of growth factor- and cytokine-driven mitogenic signaling pathways. Included among these is the cascade of intracellular events evoked by stem cell factor binding to c-Kit, a tyrosine kinase receptor which associates with and is dephosphorylated by SHP-1. Using a series of glutathione S-transferase (GST) fusion proteins containing either tyrosine-phosphorylated segments of the c-Kit cytosolic region or the SH2 domains of SHP-1, we have shown that SHP-1 interacts with c-Kit by binding selectively to the phosphorylated c-Kit juxtamembrane region and that the association of c-Kit with the larger of the two SHP-1 isoforms may be mediated through either the N-terminal or C-terminal SHP-1 SH2 domain. The results of binding assays with mutagenized GST-Kit juxtamembrane fusion proteins and competitive inhibition assays with phosphopeptides encompassing each c-Kit juxtamembrane region identified the tyrosine residue at position 569 as the major site for binding of SHP-1 to c-Kit and suggested that tyrosine 567 contributes to, but is not required for, this interaction. By analysis of Ba/F3 cells retrovirally transduced to express c-Kit receptors, phenylalanine substitution of c-Kit tyrosine residue 569 was shown to be associated with disruption of c-Kit–SHP-1 binding and induction of hyperproliferative responses to stem cell factor. Although phenylalanine substitution of c-Kit tyrosine residue 567 in the Ba/F3–c-Kit cells did not alter SHP-1 binding to c-Kit, the capacity of a second c-Kit-binding tyrosine phosphatase, SHP-2, to associate with c-Kit was markedly reduced, and the cells again showed hyperproliferative responses to stem cell factor. These data therefore identify SHP-1 binding to tyrosine 569 on c-Kit as an interaction pivotal to SHP-1 inhibitory effects on c-Kit signaling, but they indicate as well that cytosolic protein tyrosine phosphatases other than SHP-1 may also negatively regulate the coupling of c-Kit engagement to proliferation. PMID:9528781
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... storm; (2) A run-off control system from the active portion of the landfill to collect and control at least the water volume resulting from a 24-hour, 25-year storm. (b) Run-off from the active portion of...
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... storm; (2) A run-off control system from the active portion of the landfill to collect and control at least the water volume resulting from a 24-hour, 25-year storm. (b) Run-off from the active portion of...
40 CFR 258.26 - Run-on/run-off control systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... storm; (2) A run-off control system from the active portion of the landfill to collect and control at least the water volume resulting from a 24-hour, 25-year storm. (b) Run-off from the active portion of...
Designing and implementing nervous system simulations on LEGO robots.
Blustein, Daniel; Rosenthal, Nikolai; Ayers, Joseph
2013-05-25
We present a method to use the commercially available LEGO Mindstorms NXT robotics platform to test systems level neuroscience hypotheses. The first step of the method is to develop a nervous system simulation of specific reflexive behaviors of an appropriate model organism; here we use the American Lobster. Exteroceptive reflexes mediated by decussating (crossing) neural connections can explain an animal's taxis towards or away from a stimulus as described by Braitenberg and are particularly well suited for investigation using the NXT platform.(1) The nervous system simulation is programmed using LabVIEW software on the LEGO Mindstorms platform. Once the nervous system is tuned properly, behavioral experiments are run on the robot and on the animal under identical environmental conditions. By controlling the sensory milieu experienced by the specimens, differences in behavioral outputs can be observed. These differences may point to specific deficiencies in the nervous system model and serve to inform the iteration of the model for the particular behavior under study. This method allows for the experimental manipulation of electronic nervous systems and serves as a way to explore neuroscience hypotheses specifically regarding the neurophysiological basis of simple innate reflexive behaviors. The LEGO Mindstorms NXT kit provides an affordable and efficient platform on which to test preliminary biomimetic robot control schemes. The approach is also well suited for the high school classroom to serve as the foundation for a hands-on inquiry-based biorobotics curriculum.
Baker, Erin J.; Kellogg, Christina A.
2014-01-01
Coral microbiology is an expanding field, yet there is no standard DNA extraction protocol. Although many researchers depend on commercial extraction kits, no specific kit has been optimized for use with coral samples. Both soil and plant DNA extraction kits from MO BIO Laboratories, Inc., have been used by many research groups for this purpose. MO BIO recently replaced their PowerPlant® kit with an improved PowerPlantPro kit, but it was unclear how these changes would affect the kit’s use with coral samples. In order to determine which kit produced the best results, we conducted a comparison between the original PowerPlant kit, the new PowerPlantPro kit, and an alternative kit, PowerSoil, using samples from several different coral genera. The PowerPlantPro kit had the highest DNA yields, but the lack of 16S rRNA gene amplification in many samples suggests that much of the yield may be coral DNA rather than microbial DNA. The most consistent positive amplifications came from the PowerSoil kit.
STS-33 MS Carter operates translation hand control (THC) on aft flight deck
NASA Technical Reports Server (NTRS)
1989-01-01
STS-33 Mission Specialist (MS) Manley L. Carter, Jr operates translation hand control (THC) at the aft flight deck onorbit station while peering out overhead window W7. Carter's communications kit assembly headset microphone extends across his face.
Improvising a Posterior Nasal Pack with Equipment in a Basic First Aid Kit.
Royer, Allison K; Royer, Mark C
2016-09-01
Posterior epistaxis is a serious condition that can be difficult to treat in a wilderness setting. The initial standard of care involves packing the affected nostril with a 7 to 9 cm nasal pack to tamponade the bleed. These packs are often unavailable outside of the emergency or operating room. This study set out to determine whether a posterior nasal pack could be constructed from the supplies present in a basic first aid kit in order to control massive nasal hemorrhage in a wilderness setting. A basic first aid kit was utilized to construct a posterior nasal pack that was inserted into an anatomical model and visibly compared with the Rapid Rhino (Posterior, 7.5 cm; Smith & Nephew, Austin, TX) nasal packing. The shape, size, and anatomical areas of compression (ie, into nasopharynx and posterior aspect of inferior turbinate) of this pack was similar to the commercially available posterior nasal pack. Placement in an anatomical model appears to provide similar compression as the commercially available posterior pack. This technique may provide short-term hemorrhage control in cases of serious posterior nasal hemorrhage where standard treatment options are not available. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.
Furitsu, T; Tsujimura, T; Tono, T; Ikeda, H; Kitayama, H; Koshimizu, U; Sugahara, H; Butterfield, J H; Ashman, L K; Kanayama, Y
1993-01-01
The c-kit proto-oncogene encodes a receptor tyrosine kinase. Binding of c-kit ligand, stem cell factor (SCF) to c-kit receptor (c-kitR) is known to activate c-kitR tyrosine kinase, thereby leading to autophosphorylation of c-kitR on tyrosine and to association of c-kitR with substrates such as phosphatidylinositol 3-kinase (PI3K). In a human mast cell leukemia cell line HMC-1, c-kitR was found to be constitutively phosphorylated on tyrosine, activated, and associated with PI3K without the addition of SCF. The expression of SCF mRNA transcript in HMC-1 cells was not detectable by means of PCR after reverse transcription (RT-PCR) analysis, suggesting that the constitutive activation of c-kitR was ligand independent. Sequencing of whole coding region of c-kit cDNA revealed that c-kit genes of HMC-1 cells were composed of a normal, wild-type allele and a mutant allele with two point mutations resulting in intracellular amino acid substitutions of Gly-560 for Val and Val-816 for Asp. Amino acid sequences in the regions of the two mutations are completely conserved in all of mouse, rat, and human c-kit. In order to determine the causal role of these mutations in the constitutive activation, murine c-kit mutants encoding Gly-559 and/or Val-814, corresponding to human Gly-560 and/or Val-816, were constructed by site-directed mutagenesis and expressed in a human embryonic kidney cell line, 293T cells. In the transfected cells, both c-kitR (Gly-559, Val-814) and c-kitR (Val-814) were abundantly phosphorylated on tyrosine and activated in immune complex kinase reaction in the absence of SCF, whereas tyrosine phosphorylation and activation of c-kitR (Gly-559) or wild-type c-kitR was modest or little, respectively. These results suggest that conversion of Asp-816 to Val in human c-kitR may be an activating mutation and responsible for the constitutive activation of c-kitR in HMC-1 cells. Images PMID:7691885
NASA Astrophysics Data System (ADS)
Cha, Moon Hoe
2007-02-01
The NearFar program is a package for carrying out an interactive nearside-farside decomposition of heavy-ion elastic scattering amplitude. The program is implemented in Java to perform numerical operations on the nearside and farside angular distributions. It contains a graphical display interface for the numerical results. A test run has been applied to the elastic O16+Si28 scattering at E=1503 MeV. Program summaryTitle of program: NearFar Catalogue identifier: ADYP_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADYP_v1_0 Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Licensing provisions: none Computers: designed for any machine capable of running Java, developed on PC-Pentium-4 Operating systems under which the program has been tested: Microsoft Windows XP (Home Edition) Program language used: Java Number of bits in a word: 64 Memory required to execute with typical data: case dependent No. of lines in distributed program, including test data, etc.: 3484 Number of bytes distributed program, including test data, etc.: 142 051 Distribution format: tar.gz Other software required: A Java runtime interpreter, or the Java Development Kit, version 5.0 Nature of physical problem: Interactive nearside-farside decomposition of heavy-ion elastic scattering amplitude. Method of solution: The user must supply a external data file or PPSM parameters which calculates theoretical values of the quantities to be decomposed. Typical running time: Problem dependent. In a test run, it is about 35 s on a 2.40 GHz Intel P4-processor machine.
Shi, Xiarong; Sousa, Leiliane P.; Mandel-Bausch, Elizabeth M.; Tome, Francisco; Reshetnyak, Andrey V.; Hadari, Yaron; Schlessinger, Joseph; Lax, Irit
2016-01-01
Large genomic sequencing analysis as part of precision medicine efforts revealed numerous activating mutations in receptor tyrosine kinases, including KIT. Unfortunately, a single approach is not effective for inhibiting cancer cells or treating cancers driven by all known oncogenic KIT mutants. Here, we show that each of the six major KIT oncogenic mutants exhibits different enzymatic, cellular, and dynamic properties and responds distinctly to different KIT inhibitors. One class of KIT mutants responded well to anti-KIT antibody treatment alone or in combination with a low dose of tyrosine kinase inhibitors (TKIs). A second class of KIT mutants, including a mutant resistant to imatinib treatment, responded well to a combination of TKI with anti-KIT antibodies or to anti-KIT toxin conjugates, respectively. We conclude that the preferred choice of precision medicine treatments for cancers driven by activated KIT and other RTKs may rely on clear understanding of the dynamic properties of oncogenic mutants. PMID:27482095
Megakaryocytes compensate for Kit insufficiency in murine arthritis.
Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A
2017-05-01
The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.
Relationship of urinary isoprostanes to prostate cancer occurrence.
Brys, Magdalena; Morel, Agnieszka; Forma, Ewa; Krzeslak, Anna; Wilkosz, Jacek; Rozanski, Waldemar; Olas, Beata
2013-01-01
To estimate the oxidative stress in patients with prostate cancer and in a control group, we used the biomarker of lipid peroxidation-isoprostanes (8-isoPGF(2)) and the level of selected antioxidants (glucose and uric acid [UA]). The level of urinary isoprostanes was determined in patients and controls using an immunoassay kit according to the manufacturer's instruction. The levels of UA and glucose were also determined in serum by the use of UA Assay Kit and Glucose Assay Kit. We observed a statistically increased the level of isoprostanes in urine of patients with prostate cancer in compared with a control group. The concentration of tested antioxidants in blood from patients with prostate cancer was also higher than in healthy subjects. Moreover, our experiments indicate that the correlation between the increased amount of UA and the lipid peroxidation exists in prostate cancer patients (in all tested groups). Prostate cancer risk by urinary isoprostanes level was analyzed, and a positive association was found (relative risk for highest vs. lowest quartile of urinary isoprostanes = 1.6; 95 % confidence interval 1.2-2.4; p for trend = 0.03). We suggest that reactive oxygen species induce peroxidation of unsaturated fatty acid in patients with prostate cancer, and the level of isoprostanes may be used as a non-invasive marker for determination of oxidative stress. We also propose that UA may enhance the oxidative stress in patients with prostate cancer.
Signal transduction by normal isoforms and W mutant variants of the Kit receptor tyrosine kinase.
Reith, A D; Ellis, C; Lyman, S D; Anderson, D M; Williams, D E; Bernstein, A; Pawson, T
1991-09-01
Germline mutations at the Dominant White Spotting (W) and Steel (Sl) loci have provided conclusive genetic evidence that c-kit mediated signal transduction pathways are essential for normal mouse development. We have analysed the interactions of normal and mutant W/c-kit gene products with cytoplasmic signalling proteins, using transient c-kit expression assays in COS cells. In addition to the previously identified c-kit gene product (Kit+), a second normal Kit isoform (KitA+) containing an in-frame insertion, Gly-Asn-Asn-Lys, within the extracellular domain, was detected in murine mast cell cultures and mid-gestation placenta. Both Kit+ and KitA+ isoforms showed increased autophosphorylation and enhanced association with phosphatidylinositol (PI) 3' kinase and PLC gamma 1, when stimulated with recombinant soluble Steel factor. No association or increase in phosphorylation of GAP and two GAP-associated proteins, p62 and p190, was observed. The two isoforms had distinct activities in the absence of exogenous soluble Steel factor; Kit+, but not KitA+, showed constitutive tyrosine phosphorylation that was accompanied by a low constitutive level of association with PI-3' kinase and PLC gamma 1. Introduction of the point substitutions associated with W37 (Glu582----Lys) or W41 (Val831----Met) mutant alleles into c-kit expression constructs abolished (W37) or reduced (W41) the Steel factor-induced association of the Kit receptor with signalling proteins in a manner proportional to the overall severity of the corresponding W mutant phenotype. These data suggest a diversity of normal Kit signalling pathways and indicate that W mutant phenotypes result from primary defects in the Kit receptor that affect its interaction with cytoplasmic signalling proteins.
The pivotal role of fibrocytes and mast cells in mediating fibrotic reactions to biomaterials
Thevenot, Paul T.; Baker, David W.; Weng, Hong; Sun, Man-Wu; Tang, Liping
2011-01-01
Almost all biomaterial implants are surrounded by a fibrotic capsule, although the mechanism of biomaterial-mediated fibrotic reactions is mostly unclear. To search for the types of cells responsible for triggering the tissue responses, we used poly-L glycolic acid polymers capable of releasing various reagents. We first identified that CD45+ /Collagen 1+ fibrocytes are recruited and resided within the fibrotic capsule at the implant interface. Interestingly, we found that the recruitment of fibrocytes and the extent of fibrotic tissue formation (collagen type I production) were substantially enhanced and reduced by the localized release of compound 48/80 and cromolyn, respectively. Since it is well established that compound 48/80 and cromolyn alter mast cell reactions, we hypothesized that mast cells are responsible for triggering fibrocyte recruitment and subsequent fibrotic capsule formation surrounding biomaterial implants. To directly test this hypothesis, similar studies were carried out using mast cell deficient mice, WBB6F1/J-KitW/KitW-v/, and their congenic controls. Indeed, mast cell deficient mice prompted substantially less fibrocyte and myofibroblast responses in comparison to C-57 wild type mice controls. Most interestingly, subcutaneous mast cell reconstitution of WBB6F1/J-KitW/KitW-v/J mice almost completely restored the fibrocyte response in comparison to the C-57 wild type response. These results indicate that the initial biomaterial interaction resulting in the stimulation of mast cells and degranulation byproducts not only stimulates the inflammatory cascade but significantly alters the downstream fibrocyte response and degree of fibrosis. PMID:21864899
78 FR 54751 - Airworthiness Directives; Bell Helicopter Textron Canada Inc. Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-06
... certain part-numbered engine auto-relight kit control boxes. This AD was prompted by a design review that revealed the control box chipset did not meet the required temperature range requirements, which could cause the control box to malfunction, disabling the engine auto-relight system. The actions of this AD...
Parvin, C A
1993-03-01
The error detection characteristics of quality-control (QC) rules that use control observations within a single analytical run are investigated. Unlike the evaluation of QC rules that span multiple analytical runs, most of the fundamental results regarding the performance of QC rules applied within a single analytical run can be obtained from statistical theory, without the need for simulation studies. The case of two control observations per run is investigated for ease of graphical display, but the conclusions can be extended to more than two control observations per run. Results are summarized in a graphical format that offers many interesting insights into the relations among the various QC rules. The graphs provide heuristic support to the theoretical conclusions that no QC rule is best under all error conditions, but the multirule that combines the mean rule and a within-run standard deviation rule offers an attractive compromise.
Germline mutations of KIT in gastrointestinal stromal tumor (GIST) and mastocytosis.
Ke, Hengning; Kazi, Julhash U; Zhao, Hui; Sun, Jianmin
2016-01-01
Somatic mutations of KIT are frequently found in mastocytosis and gastrointestinal stromal tumor (GIST), while germline mutations of KIT are rare, and only found in few cases of familial GIST and mastocytosis. Although ligand-independent activation is the common feature of KIT mutations, the phenotypes mediated by various germline KIT mutations are different. Germline KIT mutations affect different tissues such as interstitial cells of Cajal (ICC), mast cells or melanocytes, and thereby lead to GIST, mastocytosis, or abnormal pigmentation. In this review, we summarize germline KIT mutations in familial mastocytosis and GIST and discuss the possible cellular context dependent transforming activity of KIT mutations.
The challenges of lean manufacturing implementation in kitting assembly
NASA Astrophysics Data System (ADS)
Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.
2017-10-01
Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.
No GIST-type c-kit gain of function mutations in neuroblastic tumours
Korja, M; Finne, J; Salmi, T T; Haapasalo, H; Tanner, M; Isola, J
2005-01-01
Aims: Neuroblastic tumours (NTs) have been shown to respond to imatinib treatment in vivo and in vitro, possibly via inactivating the c-kit receptor. The purpose of this study was to identify gastrointestinal stromal tumour (GIST)-type c-kit gene associated mutations in exons 9, 11, 13, and 17 in NTs to recognise a subset of tumours that would probably respond to imatinib treatment. Methods: Expression of the c-kit protein was detected immunohistochemically in a total of 37 archival paraffin wax embedded NTs using polyclonal rabbit antihuman c-kit antibody. After immunohistochemistry, c-kit gene associated chromosomal mutations in all cases of NT were detected with denaturing high performance liquid chromatography (HPLC). Results: Denaturing HLPC analysis did not reveal GIST-type mutations in four immunohistochemically detected c-kit positive or in 33 c-kit negative NTs. Conclusions: c-kit receptor expression and GIST-type c-kit gene mutations are rare events in NTs. Oncogenic activation of c-kit in NTs presumably differs from that of GISTs, which may influence their responsiveness to imatinib treatment. Whether c-kit has an essential role in the pathogenesis of NTs remains to be investigated. PMID:15976348
Using generic tool kits to build intelligent systems
NASA Technical Reports Server (NTRS)
Miller, David J.
1994-01-01
The Intelligent Systems and Robots Center at Sandia National Laboratories is developing technologies for the automation of processes associated with environmental remediation and information-driven manufacturing. These technologies, which focus on automated planning and programming and sensor-based and model-based control, are used to build intelligent systems which are able to generate plans of action, program the necessary devices, and use sensors to react to changes in the environment. By automating tasks through the use of programmable devices tied to computer models which are augmented by sensing, requirements for faster, safer, and cheaper systems are being satisfied. However, because of the need for rapid cost-effect prototyping and multi-laboratory teaming, it is also necessary to define a consistent approach to the construction of controllers for such systems. As a result, the Generic Intelligent System Controller (GISC) concept has been developed. This concept promotes the philosophy of producing generic tool kits which can be used and reused to build intelligent control systems.
2011-01-01
Background Several proteins that promote angiogenesis are overexpressed in hepatocellular carcinoma (HCC) and have been implicated in disease pathogenesis. Sunitinib has antiangiogenic activity and is an oral multitargeted inhibitor of vascular endothelial growth factor receptors (VEGFRs)-1, -2, and -3, platelet-derived growth factor receptors (PDGFRs)-α and -β, stem-cell factor receptor (KIT), and other tyrosine kinases. In a phase II study of sunitinib in advanced HCC, we evaluated the plasma pharmacodynamics of five proteins related to the mechanism of action of sunitinib and explored potential correlations with clinical outcome. Methods Patients with advanced HCC received a starting dose of sunitinib 50 mg/day administered orally for 4 weeks on treatment, followed by 2 weeks off treatment. Plasma samples from 37 patients were obtained at baseline and during treatment and were analyzed for vascular endothelial growth factor (VEGF)-A, VEGF-C, soluble VEGFR-2 (sVEGFR-2), soluble VEGFR-3 (sVEGFR-3), and soluble KIT (sKIT). Results At the end of the first sunitinib treatment cycle, plasma VEGF-A levels were significantly increased relative to baseline, while levels of plasma VEGF-C, sVEGFR-2, sVEGFR-3, and sKIT were significantly decreased. Changes from baseline in VEGF-A, sVEGFR-2, and sVEGFR-3, but not VEGF-C or sKIT, were partially or completely reversed during the first 2-week off-treatment period. High levels of VEGF-C at baseline were significantly associated with Response Evaluation Criteria in Solid Tumors (RECIST)-defined disease control, prolonged time to tumor progression (TTP), and prolonged overall survival (OS). Baseline VEGF-C levels were an independent predictor of TTP by multivariate analysis. Changes from baseline in VEGF-A and sKIT at cycle 1 day 14 or cycle 2 day 28, and change in VEGF-C at the end of the first off-treatment period, were significantly associated with both TTP and OS, while change in sVEGFR-2 at cycle 1 day 28 was an independent predictor of OS. Conclusions Baseline plasma VEGF-C levels predicted disease control (based on RECIST) and were positively associated with both TTP and OS in this exploratory analysis, suggesting that this VEGF family member may have utility in predicting clinical outcome in patients with HCC who receive sunitinib. Trial registration ClinicalTrials.gov: NCT00247676 PMID:21787417
Pim1 kinase regulates c-Kit gene translation.
An, Ningfei; Cen, Bo; Cai, Houjian; Song, Jin H; Kraft, Andrew; Kang, Yubin
2016-01-01
Receptor tyrosine kinase, c-Kit (CD117) plays a pivotal role in the maintenance and expansion of hematopoietic stem/progenitor cells (HSPCs). Additionally, over-expression and/or mutational activation of c-Kit have been implicated in numerous malignant diseases including acute myeloid leukemia. However, the translational regulation of c-Kit expression remains largely unknown. We demonstrated that loss of Pim1 led to specific down-regulation of c-Kit expression in HSPCs of Pim1 -/- mice and Pim1 -/- 2 -/- 3 -/- triple knockout (TKO) mice, and resulted in attenuated ERK and STAT3 signaling in response to stimulation with stem cell factor. Transduction of c-Kit restored the defects in colony forming capacity seen in HSPCs from Pim1 -/- and TKO mice. Pharmacologic inhibition and genetic modification studies using human megakaryoblastic leukemia cells confirmed the regulation of c-Kit expression by Pim1 kinase: i.e., Pim1-specific shRNA knockdown down-regulated the expression of c-Kit whereas overexpression of Pim1 up-regulated the expression of c-Kit. Mechanistically, inhibition or knockout of Pim1 kinase did not affect the transcription of c-Kit gene. Pim1 kinase enhanced c-Kit 35 S methionine labeling and increased the incorporation of c-Kit mRNAs into the polysomes and monosomes, demonstrating that Pim1 kinase regulates c-Kit expression at the translational level. Our study provides the first evidence that Pim1 regulates c-Kit gene translation and has important implications in hematopoietic stem cell transplantation and cancer treatment.
Early kit mortality and growth in farmed mink are affected by litter size rather than nest climate.
Schou, T M; Malmkvist, J
2017-09-01
We investigated the effects of nest box climate on early mink kit mortality and growth. We hypothesised that litters in warm nest boxes experience less hypothermia-induced mortality and higher growth rates during the 1st week of life. This study included data from 749, 1-year-old breeding dams with access to nesting materials. Kits were weighed on days 1 and 7, dead kits were collected daily from birth until day 7 after birth, and nest climate was measured continuously from days 1 to 6. We tested the influences of the following daily temperature (T) and humidity (H) parameters on the number of live-born kit deaths and kit growth: T mean, T min, T max, T var (fluctuation) and H mean. The nest microclimate experienced by the kits was buffered against the ambient climate, with higher temperatures and reduced climate fluctuation. Most (77.0%) live-born kit deaths in the 1st week occurred on days 0 and 1. Seven of 15 climate parameters on days 1 to 3 had significant effects on live-born kit mortality. However, conflicting effects among days, marginal effects and late effects indicated that climate was not the primary cause of kit mortality. Five of 30 climate parameters had significant effects on kit growth. Few and conflicting effects indicated that the climate effect on growth was negligible. One exception was that large nest temperature fluctuations on day 1 were associated with reduced deaths of live-born kit (P<0.001) and increased kit growth (P=0.003). Litter size affected kit vitality; larger total litter size at birth was associated with greater risks of kit death (P<0.001) and reduced growth (P<0.001). The number of living kits in litters had the opposite effect, as kits in large liveborn litters had a reduced risk of death (P<0.001) and those with large mean litter size on days 1 to 7 had increased growth (P=0.026). Nest box temperature had little effect on early kit survival and growth, which could be due to dams' additional maternal behaviour. Therefore, we cannot confirm that temperature is the primary reason for kit mortality, under the conditions of plenty straw access for maternal nest building. Instead, prenatal and/or parturient litter size is the primary factor influencing early kit vitality. The results indicate that the focus should be on litter size and dam welfare around the times of gestation and birth to increase early kit survival in farmed mink.
The clinical significance of c-Kit mutations in metastatic oral mucosal melanoma in China.
Ma, Xuhui; Wu, Yunteng; Zhang, Tian; Song, Hao; Jv, Houyu; Guo, Wei; Ren, Guoxin
2017-10-10
c-Kit mutations are frequently detected in mucosal melanomas, but their clinical significance in metastatic oral mucosal melanomas (OMM) remains unclear. The main purpose of this study was to investigate the clinical and pathological features of metastatic OMMs with c-Kit mutations and the efficiency of the tyrosine kinase inhibitor imatinib in treating metastatic OMMs. We found thatresidual primary lesion and neck lymph nodes could act as independent prognostic factors in metastatic OMM patients. c-Kit mutations were detected in 22 out of 139 (15.8%) metastatic OMM patients. Under chemotherapy, the overall survival (OS) of c-Kit mutant patients was significantly shorter than that of wild-type patients. The Ki67 expression was significantly higher in c-Kit mutant patients than in wild-type patients. In distant metastatic OMM patients with c-Kit mutations, the treatment with c-Kit inhibitor resulted in a better OS. In conclusion, residual primary lesion, cervical lymph nodes and c-Kit mutations act as adverse prognostic factors of metastatic OMMs. The Kit inhibitor imatinib could benefit metastatic OMM patients with c-Kit mutations.
40 CFR 1060.104 - What running loss emission control requirements apply?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What running loss emission control... STATIONARY EQUIPMENT Emission Standards and Related Requirements § 1060.104 What running loss emission control requirements apply? (a) Engines and equipment must meet running loss requirements as follows: (1...
Run-to-Run Optimization Control Within Exact Inverse Framework for Scan Tracking.
Yeoh, Ivan L; Reinhall, Per G; Berg, Martin C; Chizeck, Howard J; Seibel, Eric J
2017-09-01
A run-to-run optimization controller uses a reduced set of measurement parameters, in comparison to more general feedback controllers, to converge to the best control point for a repetitive process. A new run-to-run optimization controller is presented for the scanning fiber device used for image acquisition and display. This controller utilizes very sparse measurements to estimate a system energy measure and updates the input parameterizations iteratively within a feedforward with exact-inversion framework. Analysis, simulation, and experimental investigations on the scanning fiber device demonstrate improved scan accuracy over previous methods and automatic controller adaptation to changing operating temperature. A specific application example and quantitative error analyses are provided of a scanning fiber endoscope that maintains high image quality continuously across a 20 °C temperature rise without interruption of the 56 Hz video.
Jourdil, Jean-François; Némoz, Benjamin; Gautier-Veyret, Elodie; Romero, Charlotte; Stanke-Labesque, Françoise
2018-03-30
Adalimumab (ADA) and infliximab (IFX) are therapeutic monoclonal antibodies (TMabs) targeting tumor necrosis factor-alpha (TNFα). They are used to treat inflammatory diseases. Clinical trials have suggested that therapeutic drug monitoring for ADA or IFX could improve treatment response and cost-effectiveness. However, ADA and IFX were quantified by ELISA in all these studies, and the discrepancies between the results obtained raise questions about their reliability.We describe here the validation of a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of ADA and IFX in human samples. Full-length antibodies labeled with stable isotopes were added to plasma samples as an internal standard. Samples were then prepared using Mass Spectrometry Immuno Assay (MSIA) followed by trypsin digestion prior ADA and IFX quantification by LC-MS/MS.ADA and IFX were quantified in serum from patients treated with ADA (n=21) or IFX (n=22), and the concentrations obtained were compared with those obtained with a commercial ELISA kit. The chromatography run lasted 8.6 minutes and the quantification range was 1 to 26 mg/L. The method was reproducible, repeatable and accurate. For both levels of internal quality control, for ADA and IFX inter and intra-day coefficients of variation and accuracies were all within 15%, in accordance with FDA recommendations. No significant cross-contamination effect was noted.Good agreement was found between LC-MS/MS and ELISA results, for both ADA and IFX. This LC-MS/MS method can be used for the quantification of ADA and IFX in a single analytical run and for the optimization of LC-MS/MS resource use in clinical pharmacology laboratories.
Carvalho, Maria Isabel; Pires, Isabel; Dias, Marlene; Prada, Justina; Gregório, Hugo; Lobo, Luis; Queiroga, Felisbina
2015-01-01
In this study 80 malignant CMT were submitted to immunohistochemical detection of CD3, c-kit, VEGF, and CD31, together with clinicopathological parameters of tumor aggressiveness. CD3+ T-cells and c-kit overexpression revealed a positive correlation with VEGF (r = 0.503, P < 0.0001; r = 0.284, P = 0.023 for CD3 and c-kit, resp.) and CD31 (r = 0.654, P < 0.0001; r = 0.365, P = 0.003 for CD3 and c-kit, resp.). A significant association (P = 0.039) and a positive correlation (r = 0.263, P = 0.039) between CD3 and c-kit were also observed. High CD3/VEGF, c-kit/VEGF, and CD3/c-kit tumors were associated with elevated grade of malignancy (P < 0.0001 for all groups), presence of intravascular emboli (P < 0.0001 for CD3/VEGF and CD3/c-kit; P = 0.002 for c-kit/VEGF), and presence of lymph node metastasis (P < 0.0001 for all groups). Tumors with high CD3/VEGF (P = 0.006), c-kit/VEGF (P < 0.0001), and CD3/c-kit (P = 0.002) were associated with poor prognosis. Interestingly high c-kit/VEGF tumors retained their significance by multivariate analysis arising as independent prognostic factor. PMID:26346272
Yu, Yang; Jiang, Jiang; He, Yi; Wang, Wei; Shen, Chen; Yang, Bo
2017-08-01
Chronic prostatitis (CP) is a common urological disorder, with bladder voiding dysfunction being the primary clinical manifestation. Resveratrol is polyphenolic compound isolated from numerous plants, with widely‑reported anti-inflammatory properties. The present study aimed to investigate whether resveratrol may improve overactive bladder in rats with CP and to investigate the underlying molecular mechanisms. Furthermore, the potential pharmacological synergy between resveratrol and solifenacin was also investigated as a potential treatment for CP. Following the successful establishment of a rat model of CP by subcutaneously injecting DPT vaccine, rats were treated with resveratrol or a combination of resveratrol + solifenacin. Bladder pressure and volume tests were performed to investigate the effect of resveratrol and solifenacin on urinary dysfunction in rats with chronic prostatitis. Western blot analysis and immunohistochemical staining were used to examine the expression of c‑Kit receptor, stem cell factor (SCF), AKT and phosphorylated‑AKT (p‑AKT) in the bladder tissue. The results of the bladder pressure and volume test indicated that the maximum capacity of the bladder, residual urine volume and maximum voiding pressure in the control group were 0.57 ml, 0.17 ml and 29.62 cm H2O, respectively. These values were increased by 71, 27 and 206% in rats in the CP group compared with the control group. Following treatment with resveratrol, the results in the resveratrol group were reduced by 25.77, 44.23 and 13.32% compared with the CP group. The results of western blot analysis, immunohistochemical staining and immunofluorescence labeling demonstrate that the protein expression of SCF, c‑Kit and p‑AKT in the bladder of rats in the CP group was 4.32, 6.13 and 6.31 times higher compared with the control group, respectively. Following treatment with resveratrol, protein expression was significantly reduced. However, no significant differences were observed between the protein expression of the SCF, c‑Kit and p‑AKT in the bladder between the resveratrol and combination groups. In conclusion, resveratrol may improve overactive bladder by downregulating the protein expression of SCF, c‑Kit and p‑AKT in the bladder of rats with CP. Furthermore, a combination of resveratrol and solifenacin may have potential pharmacological synergy as a treatment for patients with CP.
An Interactive Tool for Discrete Phase Analysis in Two-Phase Flows
NASA Technical Reports Server (NTRS)
Dejong, Frederik J.; Thoren, Stephen J.
1993-01-01
Under a NASA MSFC SBIR Phase 1 effort an interactive software package has been developed for the analysis of discrete (particulate) phase dynamics in two-phase flows in which the discrete phase does not significantly affect the continuous phase. This package contains a Graphical User Interface (based on the X Window system and the Motif tool kit) coupled to a particle tracing program, which allows the user to interactively set up and run a case for which a continuous phase grid and flow field are available. The software has been applied to a solid rocket motor problem, to demonstrate its ease of use and its suitability for problems of engineering interest, and has been delivered to NASA Marshall Space Flight Center.
Pawlak, Dariusz; Rangger, Christine; Kolenc Peitl, Petra; Garnuszek, Piotr; Maurin, Michał; Ihli, Laura; Kroselj, Marko; Maina, Theodosia; Maecke, Helmut; Erba, Paola; Kremser, Leopold; Hubalewska-Dydejczyk, Alicja; Mikołajczak, Renata; Decristoforo, Clemens
2016-03-31
A variety of radiolabelled minigastrin analogues targeting the cholecystokinin 2 (CCK2) receptor were developed and compared in a concerted preclinical testing to select the most promising radiotracer for diagnosis and treatment of medullary thyroid carcinoma (MTC). DOTA-DGlu-DGlu-DGlu-DGlu-DGlu-DGlu-Ala-Tyr-Gly-Trp-Met-Asp-Phe-NH2 (CP04) after labelling with (111)In displayed excellent characteristics, such as high stability, receptor affinity, specific and persistent tumour uptake and low kidney retention in animal models. Therefore, it was selected for further clinical evaluation within the ERA-NET project GRAN-T-MTC. Here we report on the development of a pharmaceutical freeze-dried formulation of the precursor CP04 for a first multi-centre clinical trial with (111)In-CP04 in MTC patients. The kit formulation was optimised by adjustment of buffer, additives and radiolabelling conditions. Three clinical grade batches of a final kit formulation with two different amounts of peptide (10 or 50 μg) were prepared and radiolabelled with (111)In. Quality control and stability assays of both the kits and the resulting radiolabelled compound were performed by HPLC analysis. Use of ascorbic acid buffer (pH4.5) allowed freeze-drying of the kit formulation with satisfactory pellet-formation. Addition of methionine and gentisic acid as well as careful selection of radiolabelling temperature was required to avoid extensive oxidation of the Met(11)-residue. Trace metal contamination, in particular Zn, was found to be a major challenge during the pharmaceutical filling process in particular for the 10 μg formulation. The final formulations contained 10 or 50 μg CP04, 25mg ascorbic acid, 0.5mg gentisic acid and 5mg L-methionine. The radiolabelling performed by incubation of 200-250 MBq (111)InCl3 at 90 °C for 15 min resulted in reproducible radiochemical purity (RCP) >94%. Kit-stability was proven for >6 months at +5 °C and at +25 °C. The radiolabelled product was stable for >4h at +25 °C. A kit formulation to prepare (111)In-CP04 for clinical application was developed, showing high stability of the kit as well as high RCP of the final product. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M
2015-03-01
This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.
A meta-analysis of prognostic value of KIT mutation status in gastrointestinal stromal tumors
Jiang, Zhiqiang; Zhang, Jian; Li, Zhi; Liu, Yingjun; Wang, Daohai; Han, Guangsen
2016-01-01
Numerous types of KIT mutations have been reported in gastrointestinal stromal tumors (GISTs); however, controversy still exists regarding their clinicopathological significance. In this study, we reviewed the publicly available literature to assess the data by a meta-analysis to characterize KIT mutations and different types of KIT mutations in prognostic prediction in patients with GISTs. Twenty-eight studies that included 4,449 patients were identified and analyzed. We found that KIT mutation status was closely correlated with size of tumors and different mitosis indexes, but not with tumor location. KIT mutation was also observed to be significantly correlated with tumor recurrence, metastasis, as well as the overall survival of patients. Interestingly, there was higher risk of progression in KIT exon 9-mutated patients than in exon 11-mutated patients. Five-year relapse-free survival (RFS) rate was significantly higher in KIT exon 11-deleted patients than in those with other types of KIT exon 11 mutations. In addition, RFS for 5 years was significantly worse in patients bearing KIT codon 557–558 deletions than in those bearing other KIT exon 11 deletions. Our results strongly support the hypothesis that KIT mutation status is another evaluable factor for prognosis prediction in GISTs. PMID:27350754
Targeting c-KIT (CD117) by dasatinib and radotinib promotes acute myeloid leukemia cell death.
Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jeong, Yoo Kyung; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk
2017-11-10
Dasatinib and radotinib are oral BCR-ABL tyrosine kinase inhibitors that were developed as drugs for the treatment of chronic myeloid leukemia. We report here that the c-KIT (CD117) targeting with dasatinib and radotinib promotes acute myeloid leukemia (AML) cell death, and c-KIT endocytosis is essential for triggering c-KIT-positive AML cell death by dasatinib and radotinib during the early stages. In addition, dasatinib and radotinib reduce heat shock protein 90β (HSP90β) expression and release Apaf-1 in c-KIT-positive AML cells. Finally, this activates a caspase-dependent apoptotic pathway in c-KIT-positive AML cells. Moreover, the inhibition of c-KIT endocytosis by dynamin inhibitor (DY) reversed cell viability and c-KIT expression by dasatinib and radotinib. HSP90β expression was recovered by DY in c-KIT-positive AML cells as well. Furthermore, the effect of radotinib on c-KIT and HSP90β showed the same pattern in a xenograft animal model using HEL92.1.7 cells. Therefore, dasatinib and radotinib promote AML cell death by targeting c-KIT. Taken together, these results indicate that dasatinib and radotinib treatment have a potential role in anti-leukemic therapy on c-KIT-positive AML cells.
KIT Inhibition by Imatinib in Patients with Severe Refractory Asthma
Cahill, Katherine N.; Katz, Howard R.; Cui, Jing; Lai, Juying; Kazani, Shamsah; Crosby-Thompson, Allison; Garofalo, Denise; Castro, Mario; Jarjour, Nizar; DiMango, Emily; Erzurum, Serpil; Trevor, Jennifer L.; Shenoy, Kartik; Chinchilli, Vernon M.; Wechsler, Michael E.; Laidlaw, Tanya M.; Boyce, Joshua A.; Israel, Elliot
2017-01-01
BACKGROUND Mast cells are present in the airways of patients who have severe asthma despite glucocorticoid treatment; these cells are associated with disease characteristics including poor quality of life and inadequate asthma control. Stem cell factor and its receptor, KIT, are central to mast-cell homeostasis. We conducted a proof-of-principle trial to evaluate the effect of imatinib, a KIT inhibitor, on airway hyper-responsiveness, a physiological marker of severe asthma, as well as on airway mast-cell numbers and activation in patients with severe asthma. METHODS We conducted a randomized, double-blind, placebo-controlled, 24-week trial of imatinib in patients with poorly controlled severe asthma who had airway hyperresponsiveness despite receiving maximal medical therapy. The primary end point was the change in airway hyperresponsiveness, measured as the concentration of methacholine required to decrease the forced expiratory volume in 1 second by 20% (PC20). Patients also underwent bronchoscopy. RESULTS Among the 62 patients who underwent randomization, imatinib treatment reduced airway hyperresponsiveness to a greater extent than did placebo. At 6 months, the methacholine PC20 increased by a mean (±SD) of 1.73±0.60 doubling doses in the imatinib group, as compared with 1.07±0.60 doubling doses in the placebo group (P = 0.048). Imatinib also reduced levels of serum tryptase, a marker of mast-cell activation, to a greater extent than did placebo (decrease of 2.02±2.32 vs. 0.56±1.39 ng per milliliter, P = 0.02). Airway mast-cell counts declined in both groups. Muscle cramps and hypophosphatemia were more common in the imatinib group than in the placebo group. CONCLUSIONS In patients with severe asthma, imatinib decreased airway hyperresponsiveness, mast-cell counts, and tryptase release. These results suggest that KIT-dependent processes and mast cells contribute to the pathobiologic basis of severe asthma. (Funded by the National Institutes of Health and others; ClinicalTrials.gov number, NCT01097694.) PMID:28514613
NASA Astrophysics Data System (ADS)
Astutik, J.
2017-02-01
Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of food additives.
Integrated Real-Time Control and Imaging System for Microbiorobotics and Nanobiostructures
2016-01-11
kit with a control board and ALP 4.1 basic controller suite. The digital micromirror device is the highest resolution 16:9 aspect ratio system. This...in Figure 1, consisted of the following: (1) digital micromirror device (DMD) and controller, (2) an inverted epifluorescence microscope with a flat...accompanying control board and ALP 4.1 basic controller suite. The digital micromirror device is currently the highest commercially available
[Development of surgical antibioprophylaxis kits: evaluation of the impact on prescribing habits].
Aouizerate, P; Guizard, M
2002-01-01
In our hospital, surgical antibioprophylaxis (ATBP) was too often administered too late, thus raising the infectious risk. Antibiotic stocks of the anaesthesia department were also systematically used, instead of nominal prescriptions of these drugs. The pharmacy could neither charge antibiotics to each surgical department nor quantify and differentiate ATBP from curative antibiotic therapy. The pharmacy and anaesthesia departments therefore set out to standardize surgical ATBP, in order to adapt this treatment to each surgical indication, and particularly in the case of allergy to beta-lactamase antibiotics (second line treatment kits). Consequently, prescription forms were developed and supplied to each surgery department, as well as ATBP kits. The kits were prepared and distributed by the pharmacy, and comprised boxes containing antibiotics in sufficient quantities to respect the protocols approved by the French Society of Anaesthesia and Resuscitation (SFAR). A protocol describing prescriptions, dispensation and administration has been presented to physicians and nurses. Fifteen surgical departments were included in our study and 30 different kits were prepared. From 1998 to 2001, 5586 surgical operations required administration of a kit (second line treatment kits in 5% of cases): 1848 (33%) in visceral surgery; 764 (13.8%) in urology; 802 (14%) in orthopaedics; 13 (0.2%) in vascular and thoracic surgery; 1236 (22%) in ear-nose-throat (ENT), periodontics and ophtalmology, and 923 (17%) in gynaecology and obstetrics. 93% of filled prescriptions forms were spontaneously returned to the pharmacy, the others were obtained during the renewal of kit stocks. The cost (over 4 years) of ATBP was quantified: 157,871 F for the 15 departments included, 26,123 F in visceral surgery, 13,520 F in urology, 73,741 F in orthopaedics, 569 F in vascular surgery, 39,720 F in ENT/ophthalmology/periodontics and 4,198 F in gynaecology and obstetrics. According to the Altemeier classification, 2226 class I, 3151 class II, and 209 class III surgical operations were performed. Since the kits have been brought into use, the committee for the protection against nosocomial infections (CLIN) has observed a reduction in the incidence of post-operative infections, according to the Altemeier classification: from 1.6% to 0.5% in class I, from 6.5% to 4.3% in class II, and from 11% to 8.5% in class III. The difference was statistically significant only for classes I (p < 0.01) and II (p < 0.001), and unchanged for class III (p = 0.3). No analysis was carried out for class IV (curative treatments). Both nurses and physicians have greatly appreciated the implementation of this organization. The advantage in terms of post-operative infections, administration exhaustiveness and stock management is obvious. The prescribed kits were systematically appropriate for the surgical interventions. In orthopaedics, cefamandole was used over 24 h (188 kits) in ligament plasty and osteotomy, or for 48 h (499 kits) in prosthetic surgery; 24 amoxicillin/clavulanic acid (first line) and 9 clindamycin/gentamicin (second line) single dose kits have been prescribed in traumatic indications. In ophthalmology, kits were only prescribed in endophtalmitis (24 ofloxacin/fosfomycin single amount kits), implant replacement or cornea graft (1076 ofloxacin 24 h kits) and cataract surgery in diabetic patients (12 ofloxacin single amount kits). In ENT and periodontics, 124 surgical operations required cefazolin single dose kits. In vascular surgery, 5 pefloxacin/gentamicin 48 h kits and 1 amoxicillin/clavulanic acid 48 h kit were used in contaminated limb amputation, 1 cefamandole 48 h kit in class I surgery and 1 vancomycin 24 h kit (betalactamase antibiotic allergy); in thoracic surgery, 1 cefamandole 24 h kit was used for a thoracic wound. In visceral surgery, 9 different kits have been used, depending on the opening (class II) or not (class I) of the digestive tract. 797 cefazolin (first line) and 68 clindamycin/gentamicin (second line) single dose kits were used in class I surgery, and 689 amoxicillin/clavulanic acid single dose (SD) kits in class II surgery. Specific protocols consisted of 18 ceftriaxone/metronidazole and 48 metronidazole/gentamicin SD kits in oesophagus surgery, 11 ceftriaxone and 17 gentamicin SD kits in biliary endoscopy, 137 metronidazole SD kits in proctology and 34 amoxicillin/gentamicin 6 h kits for prevention of endocarditis. In urology, 133 cefotaxime and 20 pefloxacin/gentamicin SD kits were precribed in renal lithiasis, 102 amoxicillin/clavulanic acid SD kits in cystectomy, 27 amoxicillin/gentamicin 6 h kits in endocarditis prevention and 58 cefamandole SD kits in all other indications. In gynaecology and obstetrics, 534 cefazoline and 19 clindamycin/gentamicin (second line) SD kits were used, and 370 doxycyclin SD kits were prescribed in pregnancy termination. Some departments (orthopaedics and visceral surgery) adapted the protocols to their needs, specifically with regard to treatment duration. However, these situations were quickly corrected. A constant follow-up and update of this system, associated with routine audits, should allow the maintenance and possibly the improvement of these results, hence shortening treatment duration.
Neural network-based run-to-run controller using exposure and resist thickness adjustment
NASA Astrophysics Data System (ADS)
Geary, Shane; Barry, Ronan
2003-06-01
This paper describes the development of a run-to-run control algorithm using a feedforward neural network, trained using the backpropagation training method. The algorithm is used to predict the critical dimension of the next lot using previous lot information. It is compared to a common prediction algorithm - the exponentially weighted moving average (EWMA) and is shown to give superior prediction performance in simulations. The manufacturing implementation of the final neural network showed significantly improved process capability when compared to the case where no run-to-run control was utilised.
49 CFR 173.165 - Polyester resin kits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 2 2012-10-01 2012-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... resin kits consisting of a base material component (Class 3, Packing Group II or III) and an activator...
Islam, Rafiqul; Kar, Sumit; Islam, Clarinda; Farmen, Raymond
2018-06-01
There has been an increased use of commercial kits for biomarker measurement, commensurate with the increased demand for biomarkers in drug development. However, in most cases these kits do not meet the quality attributes for use in regulated environment. The process for adaptation of these kits can be frustrating, time consuming and resource intensive. In addition, a lack of harmonized guidance for the validation of biomarker poses a significant challenge in the adaptation of kits in a regulated environment. The purpose of this perspective is to propose a tiered approach to commercial drug development kits with clearly defined quality attributes and to demonstrate how these kits can be adapted to perform analytical validation in a regulated environment.
The Use of Kits in the Analysis of Tissue Lipids Requires Validation.
Rider, T; LeBoeuf, R C; Tso, Patrick; Jandacek, R J
2016-04-01
The ready availability and ease of use of kits for the measurement of serum lipids has greatly facilitated these measurements. In many cases it would be convenient to use these kits in the determination of lipid concentrations in tissues. The successful application of serum kits in tissue analysis requires that two important issues be considered. First, the solvent system for the extraction of the lipids and the solvent used for analysis by the kit must be compatible with the reactions in the kit. Second, the concentration range in the analyzed solution must be within the range for which the kit is used. We report here that lipids in liver and adipose tissues may be significantly underestimated by the use of some kits. We recommend that the use of kits for tissue analysis of lipids be validated for the specific analysis.
Oncogenic activation of v-kit involves deletion of a putative tyrosine-substrate interaction site.
Herbst, R; Munemitsu, S; Ullrich, A
1995-01-19
The transforming gene of the Hardy-Zuckerman-4 strain of feline sarcoma virus, v-kit, arose by transduction of the cellular c-kit gene, which encodes the receptor tyrosine kinase (RTK) p145c-kit. To gain insight into the molecular basis of the v-kit transforming potential, we characterized the feline c-kit by cDNA cloning. Comparison of the feline v-kit and c-kit sequences revealed, in addition to deletions of the extracellular and transmembrane domains, three additional mutations in the v-kit oncogene product: deletion of tyrosine-569 and valine-570, the exchange of aspartate at position 761 to glycine, and replacement of the C-terminal 50 amino acids by five unrelated residues. Examinations of individual v-kit mutations in the context of chimeric receptors yielded inhibitory effects for some mutants on both autophosphorylation and substrate phosphorylation functions. In contrast, deletion of tyrosine-569 and valine-570 significantly enhanced transforming and mitogenic activities of p145c-kit, while the other mutations had no significant effects. Conservation in subclass III RTKs and the identification of the corresponding residue in beta PDGF-R, Y579, as a binding site for src family tyrosine kinases suggests an important role for Y568 in kit signal regulation and the definition of its oncogenic potential. Repositioning of Y571 by an inframe two codon deletion may be the crucial alteration resulting in enhancement of v-kit oncogenic activity.
Hara, Yasushi; Obata, Yuuki; Horikawa, Keita; Tasaki, Yasutaka; Suzuki, Kyohei; Murata, Takatsugu; Shiina, Isamu; Abe, Ryo
2017-01-01
Gain-of-function mutations in Kit receptor tyrosine kinase result in the development of a variety of cancers, such as mast cell tumours, gastrointestinal stromal tumours (GISTs), acute myeloid leukemia, and melanomas. The drug imatinib, a selective inhibitor of Kit, is used for treatment of mutant Kit-positive cancers. However, mutations in the Kit kinase domain, which are frequently found in neoplastic mast cells, confer an imatinib resistance, and cancers expressing the mutants can proliferate in the presence of imatinib. Recently, we showed that in neoplastic mast cells that endogenously express an imatinib-resistant Kit mutant, Kit causes oncogenic activation of the phosphatidylinositol 3-kinase-Akt (PI3K-Akt) pathway and the signal transducer and activator of transcription 5 (STAT5) but only on endolysosomes and on the endoplasmic reticulum (ER), respectively. Here, we show a strategy for inhibition of the Kit-PI3K-Akt pathway in neoplastic mast cells by M-COPA (2-methylcoprophilinamide), an inhibitor of this secretory pathway. In M-COPA-treated cells, Kit localization in the ER is significantly increased, whereas endolysosomal Kit disappears, indicating that M-COPA blocks the biosynthetic transport of Kit from the ER. The drug greatly inhibits oncogenic Akt activation without affecting the association of Kit with PI3K, indicating that ER-localized Kit-PI3K complex is unable to activate Akt. Importantly, M-COPA but not imatinib suppresses neoplastic mast cell proliferation through inhibiting anti-apoptotic Akt activation. Results of our M-COPA treatment assay show that Kit can activate Erk not only on the ER but also on other compartments. Furthermore, Tyr568/570, Tyr703, Tyr721, and Tyr936 in Kit are phosphorylated on the ER, indicating that these five tyrosine residues are all phosphorylated before mutant Kit reaches the plasma membrane (PM). Our study provides evidence that Kit is tyrosine-phosphorylated soon after synthesis on the ER but is unable to activate Akt and also demonstrates that M-COPA is efficacious for growth suppression of neoplastic mast cells.
Hara, Yasushi; Obata, Yuuki; Horikawa, Keita; Tasaki, Yasutaka; Suzuki, Kyohei; Murata, Takatsugu; Shiina, Isamu; Abe, Ryo
2017-01-01
Gain-of-function mutations in Kit receptor tyrosine kinase result in the development of a variety of cancers, such as mast cell tumours, gastrointestinal stromal tumours (GISTs), acute myeloid leukemia, and melanomas. The drug imatinib, a selective inhibitor of Kit, is used for treatment of mutant Kit-positive cancers. However, mutations in the Kit kinase domain, which are frequently found in neoplastic mast cells, confer an imatinib resistance, and cancers expressing the mutants can proliferate in the presence of imatinib. Recently, we showed that in neoplastic mast cells that endogenously express an imatinib-resistant Kit mutant, Kit causes oncogenic activation of the phosphatidylinositol 3-kinase-Akt (PI3K-Akt) pathway and the signal transducer and activator of transcription 5 (STAT5) but only on endolysosomes and on the endoplasmic reticulum (ER), respectively. Here, we show a strategy for inhibition of the Kit-PI3K-Akt pathway in neoplastic mast cells by M-COPA (2-methylcoprophilinamide), an inhibitor of this secretory pathway. In M-COPA-treated cells, Kit localization in the ER is significantly increased, whereas endolysosomal Kit disappears, indicating that M-COPA blocks the biosynthetic transport of Kit from the ER. The drug greatly inhibits oncogenic Akt activation without affecting the association of Kit with PI3K, indicating that ER-localized Kit-PI3K complex is unable to activate Akt. Importantly, M-COPA but not imatinib suppresses neoplastic mast cell proliferation through inhibiting anti-apoptotic Akt activation. Results of our M-COPA treatment assay show that Kit can activate Erk not only on the ER but also on other compartments. Furthermore, Tyr568/570, Tyr703, Tyr721, and Tyr936 in Kit are phosphorylated on the ER, indicating that these five tyrosine residues are all phosphorylated before mutant Kit reaches the plasma membrane (PM). Our study provides evidence that Kit is tyrosine-phosphorylated soon after synthesis on the ER but is unable to activate Akt and also demonstrates that M-COPA is efficacious for growth suppression of neoplastic mast cells. PMID:28403213
The National Birth Defects Prevention Study: a review of the methods
Reefhuis, Jennita; Gilboa, Suzanne M.; Anderka, Marlene; Browne, Marilyn L.; Feldkamp, Marcia L.; Hobbs, Charlotte A.; Jenkins, Mary M.; Langlois, Peter H.; Newsome, Kimberly B.; Olshan, Andrew F.; Romitti, Paul A.; Shapira, Stuart K.; Shaw, Gary M.; Tinker, Sarah C.; Honein, Margaret A.
2015-01-01
Background The National Birth Defects Prevention Study (NBDPS) is a large population-based multi-center case-control study of major birth defects in the United States. Methods Data collection took place from 1998 through 2013 on pregnancies ending between October 1997 and December 2011. Cases could be live born, stillborn or induced terminations, and were identified from birth defects surveillance programs in Arkansas, California, Georgia, Iowa, Massachusetts, New Jersey, New York, North Carolina, Texas and Utah. Controls were live born infants without major birth defects identified from the same geographical regions and time periods as cases via either vital records or birth hospitals. Computer-assisted telephone interviews were completed with women between 6 weeks and 24 months after the estimated date of delivery. After completion of interviews, families received buccal cell collection kits for the mother, father and infant (if living). Results There were 47,832 eligible cases and 18,272 eligible controls. Among these, 32,187 (67%) and 11,814 (65%) respectively, provided interview information about their pregnancies. Buccal cell collection kits with a cytobrush for at least one family member were returned by 19,065 case and 6,211 control families (65% and 59% of those who were sent a kit). More than 500 projects have been proposed by the collaborators and over 200 manuscripts published using data from the NBDPS through December 2014. Conclusion The NBDPS has made substantial contributions to the field of birth defects epidemiology through its rigorous design, including case classification, detailed questionnaire and specimen collection, large study population, and collaborative activities across Centers. PMID:26033852
The National Birth Defects Prevention Study: A review of the methods.
Reefhuis, Jennita; Gilboa, Suzanne M; Anderka, Marlene; Browne, Marilyn L; Feldkamp, Marcia L; Hobbs, Charlotte A; Jenkins, Mary M; Langlois, Peter H; Newsome, Kimberly B; Olshan, Andrew F; Romitti, Paul A; Shapira, Stuart K; Shaw, Gary M; Tinker, Sarah C; Honein, Margaret A
2015-08-01
The National Birth Defects Prevention Study (NBDPS) is a large population-based multicenter case-control study of major birth defects in the United States. Data collection took place from 1998 through 2013 on pregnancies ending between October 1997 and December 2011. Cases could be live born, stillborn, or induced terminations, and were identified from birth defects surveillance programs in Arkansas, California, Georgia, Iowa, Massachusetts, New Jersey, New York, North Carolina, Texas, and Utah. Controls were live born infants without major birth defects identified from the same geographical regions and time periods as cases by means of either vital records or birth hospitals. Computer-assisted telephone interviews were completed with women between 6 weeks and 24 months after the estimated date of delivery. After completion of interviews, families received buccal cell collection kits for the mother, father, and infant (if living). There were 47,832 eligible cases and 18,272 eligible controls. Among these, 32,187 (67%) and 11,814 (65%), respectively, provided interview information about their pregnancies. Buccal cell collection kits with a cytobrush for at least one family member were returned by 19,065 case and 6,211 control families (65% and 59% of those who were sent a kit). More than 500 projects have been proposed by the collaborators and over 200 manuscripts published using data from the NBDPS through December 2014. The NBDPS has made substantial contributions to the field of birth defects epidemiology through its rigorous design, including case classification, detailed questionnaire and specimen collection, large study population, and collaborative activities across Centers. © 2015 Wiley Periodicals, Inc.
Steering law for parallel mounted double-gimbaled control moment gyros
NASA Technical Reports Server (NTRS)
Kennel, H. F.
1975-01-01
Parallel mounting of double-gimbaled control moment gyros (DG CMG) is discussed in terms of simplification of the steering law. The steering law/parallel mounted DG CMG is considered to be a 'CMG kit' applicable to any space vehicle where the need for DG CMG's has been established.
40 CFR 1054.115 - What other requirements apply?
Code of Federal Regulations, 2010 CFR
2010-07-01
... POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, SMALL NONROAD SPARK-IGNITION ENGINES AND EQUIPMENT... § 1054.145(c), engines must meet applicable emission standards at all specified atmospheric pressures, except that for atmospheric pressures below 94.0 kPa you may rely on an altitude kit for all testing if...
STS-33 MS Carter operates translation hand control (THC) on aft flight deck
1989-11-27
STS033-93-011 (27 Nov 1989) --- Astronaut Manley L. Carter, Jr., STS-33 mission specialist, operates translation hand control (THC) at the aft flight deck on orbit station while peering out overhead window W7. Carter's communications kit assembly headset microphone extends across his face.
A national survey of home-based care kits for palliative HIV/AIDS care in South Africa.
Mabude, Z A; Beksinska, M E; Ramkissoon, A; Wood, S; Folsom, M
2008-09-01
The objective of this study was to assess home-based care (HBC) kits and programs in South Africa to evaluate the feasibility of scaling up kit production and distribution. South African HBC organizations received structured questionnaires; key informant interviews and a literature review were completed to assess systems for production, distribution and supply of HBC kits. Meetings with stakeholders were held in two Provinces to share and analyze the study findings. The study team distributed questionnaires to 466 organizations and conducted interviews with representatives from 45 organizations, the Provincial Department of Health (DoH) and manufacturers of kits. All identifiable HBC organizations in South Africa were included in the survey. As a result 215 HBC organizations returned questionnaires; including non-governmental organizations (56%), community-based organizations (32%) and organizations affiliated with government health departments. Two types of kits were available: a home kit and a professional kit. The demand for HBC kits exceeded availability, kit contents and availability varied considerably and the supply chain was irregular. Kit production and distribution systems were fragmented. Replenishment of kit items was problematic. End-users are mostly caregivers who have not received adequate training on their use. The study shows that substantial work has been done by HBC organizations in South Africa to respond to the need for palliative care supplies within resource constraints. The growing demand for kits exceeds the supply. There is a need to improve the supply chain management of HBC kits, strengthen referral systems and links between community-based organizations and government departments, expand training opportunities for care givers, and develop monitoring and evaluation systems.
Single-cell analysis of the fate of c-kit-positive bone marrow cells
NASA Astrophysics Data System (ADS)
Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D.; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa
2017-10-01
The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.
Single-cell analysis of the fate of c-kit-positive bone marrow cells.
Czarna, Anna; Sanada, Fumihiro; Matsuda, Alex; Kim, Junghyun; Signore, Sergio; Pereira, João D; Sorrentino, Andrea; Kannappan, Ramaswamy; Cannatà, Antonio; Hosoda, Toru; Rota, Marcello; Crea, Filippo; Anversa, Piero; Leri, Annarosa
2017-01-01
The plasticity of c-kit-positive bone marrow cells (c-kit-BMCs) in tissues different from their organ of origin remains unclear. We tested the hypothesis that c-kit-BMCs are functionally heterogeneous and only a subgroup of these cells possesses cardiomyogenic potential. Population-based assays fall short of identifying the properties of individual stem cells, imposing on us the introduction of single cell-based approaches to track the fate of c-kit-BMCs in the injured heart; they included viral gene-tagging, multicolor clonal-marking and transcriptional profiling. Based on these strategies, we report that single mouse c-kit-BMCs expand clonally within the infarcted myocardium and differentiate into specialized cardiac cells. Newly-formed cardiomyocytes, endothelial cells, fibroblasts and c-kit-BMCs showed in their genome common sites of viral integration, providing strong evidence in favor of the plasticity of a subset of BMCs expressing the c-kit receptor. Similarly, individual c-kit-BMCs, which were infected with multicolor reporters and injected in infarcted hearts, formed cardiomyocytes and vascular cells organized in clusters of similarly colored cells. The uniform distribution of fluorescent proteins in groups of specialized cells documented the polyclonal nature of myocardial regeneration. The transcriptional profile of myogenic c-kit-BMCs and whole c-kit-BMCs was defined by RNA sequencing. Genes relevant for engraftment, survival, migration, and differentiation were enriched in myogenic c-kit-BMCs, a cell subtype which could not be assigned to a specific hematopoietic lineage. Collectively, our findings demonstrate that the bone marrow comprises a category of cardiomyogenic, vasculogenic and/or fibrogenic c-kit-positive cells and a category of c-kit-positive cells that retains an undifferentiated state within the damaged heart.
Hattori, Mai; Ishikawa, Osamu; Oikawa, Daisuke; Amano, Hiroo; Yasuda, Masahito; Kaira, Kyoichi; Ishida-Yamamoto, Akemi; Nakano, Hajime; Sawamura, Daisuke; Terawaki, Shin-Ichi; Wakamatsu, Kaori; Tokunaga, Fuminori; Shimizu, Akira
2018-03-21
Piebaldism is a pigmentary disorder characterized by a white forelock and depigmented patches. Although the loss-of-function mutations in the KIT gene underlie the disease, the intracellular dynamics of the mutant KIT are largely unknown. We herein report a Japanese family with piebaldism in which the affected members showed a mild phenotype. The objective of this study is to investigate the functions and intracellular dynamics of the mutant KIT protein. We performed genetic analyses of the KIT gene using peripheral blood cells. We analyzed the intracellular localization of the mutant KIT protein in HEK293T cells transfected with wild-type (Wt) and/or mutant KIT genes. Immunoprecipitation analyses, immunoblotting and immunofluorescence studies were performed using antibodies against KIT and downstream signaling proteins. Glycosidase digestion analysis was performed to clarify the intracellular localization of KIT protein. A genetic analysis revealed a novel heterozygous mutation c.645_650delTGTGTC which results in the in-frame deletion of Val 216 and Ser 217 in the extracellular domain of KIT. Immunoprecipitation analyses confirmed that the wild and mutant KIT formed a heterodimer after treatment with stem cell factor (SCF); however, the phosphorylation of the downstream signaling factors was decreased. In an immunofluorescence study, the mutant KIT accumulated predominantly in the endoplasmic reticulum (ER) and was sparsely expressed on the cell surface. A glycosidase digestion study revealed that the mutant KIT is predominantly localized in the ER. These data reveal an aberrant function and intracellular localization of mutant KIT protein in piebaldism. Copyright © 2018 Japanese Society for Investigative Dermatology. Published by Elsevier B.V. All rights reserved.
Su, Feng; Zhang, Wentian; Liu, Jianfang
2015-01-01
It has been validated that c-kit positive (c-kit+) cells in infarcted myocardium are from bone marrow (BM). Given the recent study that in the heart, estrogen receptor alpha (ERα) is involved in adaptive mechanisms by supporting cardiomyocytes survival via post-infarct cardiac c-kit+ cells, we tested a novel hypothesis that membrane ERα (mERа) supports survival of BM c-kit+ cells and enhance protective paracrine function for cardiac repair. Our data showed that myocardial infarction (MI) leads to an increase in c-kit+ first in bone marrow and then specifically within the infarcted myocardium. Also up-regulated mERа in post-infarct BM c-kit+ cells was found in day 3 post MI. In vitro co-culture system, mERа+ enhances the beneficial effects of BM c-kit+ cells by increasing their viability and reducing apoptosis. Post-infarct c-kit+ mERа+ cells population expresses predominant ERα and holds self-renewal as well as cardiac differentiation potentials after MI. In vivo, BM c-kit+ cells reduced infarct size, fibrosis and improved cardiac function. In conclusion, BM c-kit+ mERа+ exerted significantly cardiac protection after MI. A potential important implication of this study is that the manipulation of BM c-kit+ stem cells with ERа-dependent fashion may be helpful in recovering functional performance after cardiac tissue injury. PMID:26191121
Bosbach, Benedikt; Rossi, Ferdinand; Yozgat, Yasemin; Loo, Jennifer; Zhang, Jennifer Q; Berrozpe, Georgina; Warpinski, Katherine; Ehlers, Imke; Veach, Darren; Kwok, Andrew; Manova, Katia; Antonescu, Cristina R; DeMatteo, Ronald P; Besmer, Peter
2017-10-03
Gastrointestinal stromal tumors (GISTs) predominantly harbor activating mutations in the receptor tyrosine kinase KIT. To genetically dissect in vivo the requirement of different signal transduction pathways emanating from KIT for tumorigenesis, the oncogenic Kit V558Δ mutation was combined with point mutations abrogating specific phosphorylation sites on KIT. Compared with single-mutant Kit V558Δ/+ mice, double-mutant Kit V558Δ;Y567F/Y567F knock-in mice lacking the SRC family kinase-binding site on KIT (pY567) exhibited attenuated MAPK signaling and tumor growth. Surprisingly, abrogation of the PI3K-binding site (pY719) in Kit V558Δ;Y719F/Y719F mice prevented GIST development, although the interstitial cells of Cajal (ICC), the cells of origin of GIST, were normal. Pharmacologic inhibition of the PI3K pathway in tumor-bearing Kit V558Δ/+ mice with the dual PI3K/mTOR inhibitor voxtalisib, the pan-PI3K inhibitor pilaralisib, and the PI3K-alpha-restricted inhibitor alpelisib each diminished tumor proliferation. The addition of the MEK inhibitor PD-325901 or binimetinib further decreased downstream KIT signaling. Moreover, combining PI3K and MEK inhibition was effective against imatinib-resistant Kit V558Δ;T669I/+ tumors.
Bosbach, Benedikt; Rossi, Ferdinand; Yozgat, Yasemin; Loo, Jennifer; Zhang, Jennifer Q.; Berrozpe, Georgina; Warpinski, Katherine; Ehlers, Imke; Kwok, Andrew; Manova, Katia; Antonescu, Cristina R.; DeMatteo, Ronald P.; Besmer, Peter
2017-01-01
Gastrointestinal stromal tumors (GISTs) predominantly harbor activating mutations in the receptor tyrosine kinase KIT. To genetically dissect in vivo the requirement of different signal transduction pathways emanating from KIT for tumorigenesis, the oncogenic KitV558Δ mutation was combined with point mutations abrogating specific phosphorylation sites on KIT. Compared with single-mutant KitV558Δ/+ mice, double-mutant KitV558Δ;Y567F/Y567F knock-in mice lacking the SRC family kinase-binding site on KIT (pY567) exhibited attenuated MAPK signaling and tumor growth. Surprisingly, abrogation of the PI3K-binding site (pY719) in KitV558Δ;Y719F/Y719F mice prevented GIST development, although the interstitial cells of Cajal (ICC), the cells of origin of GIST, were normal. Pharmacologic inhibition of the PI3K pathway in tumor-bearing KitV558Δ/+ mice with the dual PI3K/mTOR inhibitor voxtalisib, the pan-PI3K inhibitor pilaralisib, and the PI3K-alpha–restricted inhibitor alpelisib each diminished tumor proliferation. The addition of the MEK inhibitor PD-325901 or binimetinib further decreased downstream KIT signaling. Moreover, combining PI3K and MEK inhibition was effective against imatinib-resistant KitV558Δ;T669I/+ tumors. PMID:28923937
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
40 CFR 745.88 - Recognized test kits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have... publicizes its recognition of the first test kit that meets both the negative response and positive response...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
21 CFR 868.1100 - Arterial blood sampling kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...
46 CFR 121.710 - First-aid kits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...
19 CFR 122.132 - Sealing of aircraft liquor kits.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
46 CFR 121.710 - First-aid kits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...
19 CFR 122.132 - Sealing of aircraft liquor kits.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 19 Customs Duties 1 2011-04-01 2011-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...
21 CFR 870.1350 - Catheter balloon repair kit.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...
46 CFR 121.710 - First-aid kits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...
46 CFR 121.710 - First-aid kits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...
19 CFR 122.132 - Sealing of aircraft liquor kits.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 19 Customs Duties 1 2013-04-01 2013-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...
19 CFR 122.132 - Sealing of aircraft liquor kits.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 19 Customs Duties 1 2012-04-01 2012-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...
19 CFR 122.132 - Sealing of aircraft liquor kits.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 19 Customs Duties 1 2014-04-01 2014-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...
DEMONSTRATION BULLETIN: CLOR-N-SOIL PCB TEST KIT L2000 PCB/CHLORIDE ANALYZER - DEXSIL CORP.
DEXSIL CORP(Environmental Test Kits)The Dexsil Corporation (Dexsil) produces two test kits that detect polychlorinated biphenyls (PCB) in soil: the Dexsil Clor-N-Soil PCB Screening Kit, and the Dexsil L2000 PCB/Chloride Analyzer. The Dexsil Clor-N-Soil PCB Screening Kit extr...
Sun, Yuning; Xu, Rongfeng; Huang, Jia; Yao, Yuyu; Pan, Xiaodong; Chen, Zhongpu; Ma, Genshan
2018-02-21
C-kit-positive cardiac stem cells (CSCs) have been shown to be a promising candidate treatment for myocardial infarction and heart failure. Insulin-like growth factor (IGF)-1 is an anabolic growth hormone that regulates cellular proliferation, differentiation, senescence, and death in various tissues. Although IGF-1 promotes the migration and proliferation of c-kit-positive mouse CSCs, the underlying mechanism remains unclear. Cells were isolated from adult mouse hearts, and c-kit-positive CSCs were separated using magnetic beads. The cells were cultured with or without IGF-1, and c-kit expression was measured by Western blotting. IGF-1 induced CSC proliferation and migration, as measured through Cell Counting Kit-8 (CCK-8) and Transwell assays, respectively. The miR-193a expression was measured by quantitative real-time PCR (qPCR) assays. IGF-1 enhanced c-kit expression in c-kit-positive CSCs. The activities of the phosphoinositol 3-kinase (PI3K)/AKT signaling pathway and DNA methyltransferases (DNMTs) were enhanced, and their respective inhibitors LY294002 and 5-azacytidine (5-AZA) blunted c-kit expression. Based on the results of quantitative real-time PCR (qPCR) assays, the expression of miR-193a, which is embedded in a CpG island, was down-regulated in the IGF-1-stimulated group and negatively correlated with c-kit expression, whereas c-kit-positive CSCs infected with lentivirus carrying micro-RNA193a displayed reduced c-kit expression, migration and proliferation. IGF-1 upregulated c-kit expression in c-kit-positive CSCs resulting in enhanced CSC proliferation and migration by activating the PI3K/AKT/DNMT signaling pathway to epigenetically silence miR-193a, which negatively modifies the c-kit expression level.
Investigation of c-KIT and Ki67 expression in normal, preneoplastic and neoplastic canine prostate.
Fonseca-Alves, Carlos Eduardo; Kobayashi, Priscilla Emiko; Palmieri, Chiara; Laufer-Amorim, Renée
2017-12-06
c-KIT expression has been related to bone metastasis in human prostate cancer, but whether c-KIT expression can be similarly classified in canine prostatic tissue is unknown. This study assessed c-KIT and Ki67 expression in canine prostate cancer (PC). c-KIT gene and protein expression and Ki67 expression were evaluated in forty-four canine prostatic tissues by immunohistochemistry, RT-qPCR and western blot. Additionally, we have investigated c-KIT protein expression by immunoblotting in two primary canine prostate cancer cell lines. Eleven normal prostates, 12 proliferative inflammatory atrophy (PIA) prostates, 18 PC, 3 metastatic lesions and two prostate cancer cell cultures (PC1 and PC2) were analysed. The prostatic tissue exhibited varying degrees of membranous, cytoplasmic or membranous/cytoplasmic c-KIT staining. Four normal prostates, 4 PIA and 5 prostatic carcinomas showed positive c-KIT expression. No c-KIT immunoexpression was observed in metastases. Canine prostate cancer and PIA samples contained a higher number of Ki67-positive cells compared to normal samples. The median relative quantification (RQ) for c-KIT expression in normal, PIA and prostate cancer and metastatic samples were 0.6 (0.1-2.5), 0.7 (0.09-2.1), 0.7 (0.09-5.1) and 0.1 (0.07-0.6), respectively. A positive correlation between the number of Ki67-positive cells and c-KIT transcript levels was observed in prostate cancer samples. In the cell line, PC1 was negative for c-KIT protein expression, while PC2 was weakly positive. The present study identified a strong correlation between c-KIT expression and proliferative index, suggesting that c-KIT may influence cell proliferation. Therefore, c-KIT heterogeneous protein expression among the samples (five positive and thirteen negative prostate cancer samples) indicates a personalized approach for canine prostate cancer.
NASA Technical Reports Server (NTRS)
Williams, David E.; Spector, Lawrence N.
2009-01-01
Node 1 (Unity) flew to International Space Station (ISS) on Flight 2A. Node 1 was the first module of the United States On-Orbit Segment (USOS) launched to ISS. The Node 1 ISS Environmental Control and Life Support (ECLS) design featured limited ECLS capability. The main purpose of Node 1 was to provide internal storage by providing four stowage rack locations within the module and to allow docking of multiple modules and a truss segment to it. The ECLS subsystems inside Node 1 were routed through the element prior to launch to allow for easy integration of the attached future elements, particularly the Habitation Module which was planned to be located at the nadir docking port of Node 1. After Node 1 was on-orbit, the Program decided not to launch the Habitation Module and instead, to replace it with Node 3 (Tranquility). In 2007, the Program became concerned with a potential Russian docking port approach issue for the Russian FGB nadir docking port after Node 3 is attached to Node 1. To solve this concern the Program decided to relocate Node 3 from Node 1 nadir to Node 1 port. To support the movement of Node 3 the Program decided to build a modification kit for Node 1, an on-orbit feedthrough leak test device, and new vestibule jumpers to support the ECLS part of the relocation. This paper provides a design overview of the modification kit, a summary of the Node 1 ECLS re-verification to support the Node 3 relocation from Node 1 nadir to Node 1 port, and a status of the ECLS modification kit installation into Node 1.
Choline Alleviates Parenteral Nutrition-Associated Duodenal Motility Disorder in Infant Rats.
Zhu, Jie; Wu, Yang; Guo, Yonggao; Tang, Qingya; Lu, Ting; Cai, Wei; Huang, Haiyan
2016-09-01
Parenteral nutrition (PN) has been found to influence duodenal motility in animals. Choline is an essential nutrient, and its deficiency is related to PN-associated organ diseases. Therefore, this study was aimed to investigate the role of choline supplementation in an infant rat model of PN-associated duodenal motility disorder. Three-week-old Sprague-Dawley male rats were fed chow and water (controls), PN solution (PN), or PN plus intravenous choline (600 mg/kg) (PN + choline). Rats underwent jugular vein cannulation for infusion of PN solution or 0.9% saline (controls) for 7 days. Duodenal oxidative stress status, concentrations of plasma choline, phosphocholine, and betaine and serum tumor necrosis factor (TNF)-α were assayed. The messenger RNA (mRNA) and protein expression of c-Kit proto-oncogene protein (c-Kit) and membrane-bound stem cell factor (mSCF) together with the electrophysiological features of slow waves in the duodenum were also evaluated. Rats on PN showed increased reactive oxygen species; decreased total antioxidant capacity in the duodenum; reduced plasma choline, phosphocholine, and betaine; and enhanced serum TNF-α concentrations, which were reversed by choline intervention. In addition, PN reduced mRNA and protein expression of mSCF and c-Kit, which were inversed under choline administration. Moreover, choline attenuated depolarized resting membrane potential and declined the frequency and amplitude of slow waves in duodenal smooth muscles of infant rats induced by PN, respectively. The addition of choline to PN may alleviate the progression of duodenal motor disorder through protecting smooth muscle cells from injury, promoting mSCF/c-Kit signaling, and attenuating impairment of interstitial cells of Cajal in the duodenum during PN feeding. © 2015 American Society for Parenteral and Enteral Nutrition.
Kelvin, Elizabeth A; George, Gavin; Mwai, Eva; Nyaga, Eston; Mantell, Joanne E; Romo, Matthew L; Odhiambo, Jacob O; Starbuck, Lila; Govender, Kaymarlin
2018-01-01
We conducted a randomized controlled trial among 305 truck drivers from two North Star Alliance roadside wellness clinics in Kenya to see if offering HIV testing choices would increase HIV testing uptake. Participants were randomized to be offered (1) a provider-administered rapid blood (finger-prick) HIV test (i.e., standard of care [SOC]) or (2) a Choice between SOC or a self-administered oral rapid HIV test with provider supervision in the clinic. Participants in the Choice arm who refused HIV testing in the clinic were offered a test kit for home use with phone-based posttest counseling. We compared HIV test uptake using the Mantel Haenszel odds ratio (OR) adjusting for clinic. Those in the Choice arm had higher odds of HIV test uptake than those in the SOC arm (OR = 1.5), but the difference was not statistically significant (p = 0.189). When adding the option to take an HIV test kit for home use, the Choice arm had significantly greater odds of testing uptake (OR = 2.8, p = 0.002). Of those in the Choice arm who tested, 26.9% selected the SOC test, 64.6% chose supervised self-testing in the clinic, and 8.5% took a test kit for home use. Participants varied in the HIV test they selected when given choices. Importantly, when participants who refused HIV testing in the clinic were offered a test kit for home use, an additional 8.5% tested. Offering truck drivers a variety of HIV testing choices may increase HIV testing uptake in this key population.
Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra
2017-03-21
Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.
Coexistence of gastrointestinal stromal tumors and gastric adenocarcinomas.
Yan, Yan; Li, Ziyu; Liu, Yiqiang; Zhang, Lianhai; Li, Jiyou; Ji, Jiafu
2013-04-01
The purpose of this study is to detect the clinicopathology of gastrointestinal stromal tumors (GISTs) occurring synchronously with gastric adenocarcinomas and to unveil the potential underlying relationship between the synchronous GIST and gastric adenocarcinoma. This study included 15 patients with incidental GISTs found during operations for gastric adenocarcinoma and 30 patients who underwent gastrectomy for gastric cancer without discovering GIST between January 2005 and December 2010 at the Beijing Cancer Institute. We collected the clinicopathological data and analyzed the KIT/PDGFRA mutational status of GISTs, corresponding gastric adenocarcinoma specimens, and the normal tissue around the cancer lesions. Additionally, as a control group, the mutational status of the patients with gastric adenocarcinoma and no other tumors was assayed. Overall, 18 GISTs were found in 15 gastric adenocarcinoma patients. Multiple GIST lesions were found in three cases (20 %). The patients' age ranged from 46 to 85 years, with an average of 67.6 years. The average size of the GISTs was 0.85 cm. All mesenchymal lesions showed low proliferative activity, were of low or very low risk, and were identified as CD117-positive by immunostaining. In GIST lesions, mutations in KIT were detected in 7 out of 13 cases, and of these mutations, 6 were found in exon 11 (46.2 %), and 1 was found in exon 9 (7.7 %). A total of five deletions and one point mutation were in exon 11, and one insertion was in exon 9. Mutations were not detected in exon 17 or 13 of KIT. There was no remarkable mutation analyzed in the gastric adenocarcinoma lesions or normal tissues from either the test or control groups. Clinicopathological profiles and molecular analysis of KIT/PDGFRA showed no obvious relationship between gastric cancer and GISTs in tumor genesis, such as similar oncogene mutations.
NASA Technical Reports Server (NTRS)
Williams, David E.; Spector Lawrence N.
2010-01-01
Node 1 (Unity) flew to International Space Station (ISS) on Flight 2A. Node 1 was the first module of the United States On-Orbit Segment (USOS) launched to ISS. The Node 1 ISS Environmental Control and Life Support (ECLS) design featured limited ECLS capability. The main purpose of Node 1 was to provide internal storage by providing four stowage rack locations within the module and to allow docking of multiple modules and a truss segment to it. The ECLS subsystems inside Node 1 were routed through the element prior to launch to allow for easy integration of the attached future elements, particularly the Habitation Module which was planned to be located at the nadir docking port of Node 1. After Node I was on-orbit, the Program decided not to launch the Habitation Module and instead, to replace it with Node 3 (Tranquility). In 2007, the Program became concerned with a potential Russian docking port approach issue for the Russian FGB nadir docking port after Node 3 is attached to Node 1. To solve this concern the Program decided to relocate Node 3 from Node I nadir to Node 1 port. To support the movement of Node 3 the Program decided to build a modification kit for Node 1, an on-orbit feedthrough leak test device, and new vestibule jumpers to support the ECLS part of the relocation. This paper provides a design overview of the modification kit for Node 1, a summary of the Node 1 ECLS re-verification to support the Node 3 relocation from Node 1 nadir to Node 1 port, and a status of the ECLS modification kit installation into Node 1.
Gupta, Divya; Chandrashekar, Laxmisha; Larizza, Lidia; Colombo, Elisa A; Fontana, Laura; Gervasini, Cristina; Thappa, Devinder M; Rajappa, Medha; Rajendiran, Kalai Selvi; Sreenath, Gubbi Shamanna; Kate, Vikram
2017-02-01
Familial lentiginosis syndromes are characterized by a wide array of manifestations resulting from activation of molecular pathways which control growth, proliferation, and differentiation of a broad range of tissues. Familial gastrointestinal stromal tumors (GISTs) are often accompanied by additional features like hyperpigmentation, mastocytosis, and dysphagia. They have been described with mutations in c-kit (most commonly), platelet-derived growth factor receptor A, neurofibromatosis-1, and succinate dehydrogenase genes. We report on molecular characterization and tumor histopathology of two siblings in whom lentigines and café-au-lait macules were present along with multifocal GIST. Immuhistochemical analysis of CD34 and CD117 was performed on GIST biopsy samples from both siblings, while c-kit mutational analysis was done by PCR and direct sequencing on DNA from peripheral blood leukocytes of all family members and from paraffin-embedded gastric biopsy specimens of affected siblings. Histopathology revealed positive expression of CD117 and CD34. Mutational analysis showed the germline c.1676T>C mutation in c-kit exon 11, (p.(Val559Ala)), in the peripheral blood of both siblings and a second exon 11 mutation, c.1669T>A (p.(Trp557Arg)) in the tumor biopsy of one of them. Initiation of imatinib treatment resulted in striking resolution of their hyperpigmentation and a stable gastrointestinal disease in one of them. A c-kit mutational test in familial GISTs is indicated before initiation of imatinib therapy, as it can help predict tumor response to treatment. © 2017 The International Society of Dermatology.
Nagarale, Girish; Ravindra, S; Thakur, Srinath; Setty, Swati
2010-10-01
C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis.
Nagarale, Girish; Ravindra, S.; Thakur, Srinath; Setty, Swati
2010-01-01
Background: C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. Aim: The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. Materials and Methods: A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. Results: CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Conclusion: Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis. PMID:21731244
Disruption of c-Kit Signaling in Kit(W-sh/W-sh) Growing Mice Increases Bone Turnover.
Lotinun, Sutada; Krishnamra, Nateetip
2016-08-16
c-Kit tyrosine kinase receptor has been identified as a regulator of bone homeostasis. The c-Kit loss-of-function mutations in WBB6F1/J-Kit(W/W-v) mice result in low bone mass. However, these mice are sterile and it is unclear whether the observed skeletal phenotype is secondary to a sex hormone deficiency. In contrast, C57BL/6J-Kit(W-sh)/(W-sh) (W(sh)/W(sh)) mice, which carry an inversion mutation affecting the transcriptional regulatory elements of the c-Kit gene, are fertile. Here, we showed that W(sh)/W(sh) mice exhibited osteopenia with elevated bone resorption and bone formation at 6- and 9-week-old. The c-Kit W(sh) mutation increased osteoclast differentiation, the number of committed osteoprogenitors, alkaline phosphatase activity and mineralization. c-Kit was expressed in both osteoclasts and osteoblasts, and c-Kit expression was decreased in W(sh)/W(sh)osteoclasts, but not osteoblasts, suggesting an indirect effect of c-Kit on bone formation. Furthermore, the osteoclast-derived coupling factor Wnt10b mRNA was increased in W(sh)/W(sh) osteoclasts. Conditioned medium from W(sh)/W(sh) osteoclasts had elevated Wnt10b protein levels and induced increased alkaline phosphatase activity and mineralization in osteoblast cultures. Antagonizing Wnt10b signaling with DKK1 or Wnt10b antibody inhibited these effects. Our data suggest that c-Kit negatively regulates bone turnover, and disrupted c-Kit signaling couples increased bone resorption with bone formation through osteoclast-derived Wnt 10 b.
Exacerbated experimental autoimmune encephalomyelitis in mast-cell-deficient Kit W-sh/W-sh mice.
Piconese, Silvia; Costanza, Massimo; Musio, Silvia; Tripodo, Claudio; Poliani, Pietro L; Gri, Giorgia; Burocchi, Alessia; Pittoni, Paola; Gorzanelli, Andrea; Colombo, Mario P; Pedotti, Rosetta
2011-04-01
Mast cell (MC)-deficient c-Kit mutant Kit(W/W-v) mice are protected against experimental autoimmune encephalomyelitis (EAE), an animal model of multiple sclerosis, suggesting a detrimental role for MCs in this disease. To further investigate the role of MCs in EAE, we took advantage of a recently characterized model of MC deficiency, Kit(W-sh/W-sh). Surprisingly, we observed that myelin oligodendrocyte glycoprotein (MOG)(35-55)-induced chronic EAE was exacerbated in Kit(W-sh/W-sh) compared with Kit(+/+) mice. Kit(W-sh/W-sh) mice showed more inflammatory foci in the central nervous system (CNS) and increased T-cell response against myelin. To understand whether the discrepant results obtained in Kit(W-sh/W-sh) and in Kit(W/W-v) mice were because of the different immunization protocols, we induced EAE in these two strains with varying doses of MOG(35-55) and adjuvants. Although Kit(W-sh/W-sh) mice exhibited exacerbated EAE under all immunization protocols, Kit(W/W-v) mice were protected from EAE only when immunized with high, but not low, doses of antigen and adjuvants. Kit(W-sh/W-sh) mice reconstituted systemically, but not in the CNS, with bone marrow-derived MCs still developed exacerbated EAE, indicating that protection from disease could be exerted by MCs mainly in the CNS, and/or by other cells possibly dysregulated in Kit(W-sh/W-sh) mice. In summary, these data suggest to reconsider MC contribution to EAE, taking into account the variables of using different experimental models and immunization protocols.
Rocke, Tonie E; Smith, Susan; Marinari, Paul; Kreeger, Julie; Enama, Jeffrey T; Powell, Bradford S
2008-01-01
Previous studies have established that vaccination of black-footed ferrets (Mustela nigripes) with F1-V fusion protein by subcutaneous (SC) injection protects the animals against plague upon injection of the bacterium Yersinia pestis. This study demonstrates that the F1-V antigen can also protect ferrets against plague contracted via ingestion of a Y. pestis-infected mouse, a probable route for natural infection. Eight black-footed ferret kits were vaccinated with F1-V protein by SC injection at approximately 60 days-of-age. A booster vaccination was administered 3 mo later via SC injection. Four additional ferret kits received placebos. The animals were challenged 6 wk after the boost by feeding each one a Y. pestis-infected mouse. All eight vaccinates survived challenge, while the four controls succumbed to plague within 3 days after exposure. To determine the duration of antibody postvaccination, 18 additional black-footed ferret kits were vaccinated and boosted with F1-V by SC injection at 60 and 120 days-of-age. High titers to both F1 and V (mean reciprocal titers of 18,552 and 99,862, respectively) were found in all vaccinates up to 2 yr postvaccination, whereas seven control animals remained antibody negative throughout the same time period.
Discovery of amido-benzisoxazoles as potent c-Kit inhibitors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kunz, Roxanne K.; Rumfelt, Shannon; Chen, Ning
2010-01-12
Deregulation of the receptor tyrosine kinase c-Kit is associated with an increasing number of human diseases, including certain cancers and mast cell diseases. Interference of c-Kit signaling with multi-kinase inhibitors has been shown clinically to successfully treat gastrointestinal stromal tumors and mastocytosis. Targeted therapy of c-Kit activity may provide therapeutic advantages against off-target effects for non-oncology applications. A new structural class of c-Kit inhibitors is described, including in vitro c-Kit potency, kinase selectivity, and the observed binding mode.
ERIC Educational Resources Information Center
Schwerin, Alan
1994-01-01
Describes procedures for a hands-on activity for students that involves the construction of radio-controlled model sailplane (or glider) kits, exposure to basic aerodynamic theory and concepts, and some flight school on a midsized field. (ZWH)
Code of Federal Regulations, 2010 CFR
2010-04-01
... to promote evacuation of the contents of the lower colon. The device consists of a container for... irrigation system (§ 876.5220). (b) Classification. Class I (general controls). The device is exempt from the...
Desneux, Jérémy; Pourcher, Anne-Marie
2014-01-01
Four commercial DNA extraction kits and a minor modification in the DNA elution procedure were evaluated for the quantitation of bacteria in pig manure samples. The PowerSoil®, PowerFecal®, NucleoSpin® Soil kits and QIAamp® DNA Stool Mini kit were tested on raw manure samples and on lagoon effluents for their ability to quantify total bacteria and a subdominant bacteria specific of pig manure contamination: Lactobacillus amylovorus. The NucleoSpin® Soil kit (NS kit), and to a lesser extent the PowerFecal® kit were the most efficient methods. Regardless of the kit utilized, the modified elution procedure increased DNA yield in the lagoon effluent by a factor of 1.4 to 1.8. When tested on 10 piggery effluent samples, compared to the QIAamp kit, the NS kit combined with the modified elution step, increased by a factor up to 1.7 log10 the values of the concentration of L. amylovorus. Regardless of the type of manure, the best DNA quality and the highest concentrations of bacteria were obtained using the NS kit combined with the modification of the elution procedure. The method recommended here significantly improved quantitation of subdominant bacteria in manure. PMID:24838631
Mazzia, C; Porcher, C; Julé, Y; Christen, M O; Henry, M
2000-05-01
C-kit immunocytochemistry was performed on ultrathin sections of human distal colon. Our attention was focused on relationships between c-kit immunoreactive interstitial cells (c-kit ICs) and muscular cells and nervous elements located in the external muscular layers of the colonic wall. C-kit ICs established membrane apposition with both nerve fibers and smooth muscle cells of, respectively, the longitudinal and circular muscle layers, the myenteric area, and the extremus submucosus plexus. C-kit ICs also surrounded the external submucosus plexus and established membrane appositions with nerve elements located inside the myenteric ganglia. These membrane appositions were observed either at the level of the c-kit IC bodies or at that of their cytoplasmic processes. In some cases, membrane appositions were observed concomitantly between the c-kit ICs, nerve fibers, and smooth muscle cells. In all the regions studied, the c-kit ICs were also found to be located in the close vicinity of blood vessels and to have established close contacts with non-immunoreactive fibroblast-like cells. The results of the present study shed essential light on the relationships of c-kit ICs with the neighboring muscle cells and nerve elements, and confirm that the intercalated c-kit ICs well fit with the so-called "interstitial cells of Cajal".
Rupar, Kaja; Moharram, Sausan A; Kazi, Julhash U; Rönnstrand, Lars
2018-04-23
KIT is a receptor tyrosine kinase (RTK) involved in several cellular processes such as regulation of proliferation, survival and differentiation of early hematopoietic cells, germ cells and melanocytes. Activation of KIT results in phosphorylation of tyrosine residues in the receptor, and recruitment of proteins that mediate downstream signaling and also modulate receptor signaling. Here we show that the SRC-like adaptor protein 2 (SLAP2) binds to wild-type KIT in a ligand-dependent manner and is furthermore found constitutively associated with the oncogenic mutant KIT-D816V. Peptide fishing analysis mapped pY568 and pY570 as potential SLAP2 association sites in KIT, which overlaps with the SRC binding sites in KIT. Expression of SLAP2 in cells expressing the transforming mutant KIT-D816V led to reduced cell viability and reduced colony formation. SLAP2 also partially blocked phosphorylation of several signal transduction molecules downstream of KIT such as AKT, ERK, p38 and STAT3. Finally, SLAP2 expression enhanced ubiquitination of KIT and its subsequent degradation. Taken together, our data demonstrate that SLAP2 negatively modulates KIT-D816V-mediated transformation by enhancing degradation of the receptor.
Toothpaste allergy as a cause of cheilitis in Israeli patients.
Lavy, Yaron; Slodownik, Dan; Trattner, Akiva; Ingber, Arieh
2009-01-01
Allergic contact cheilitis may appear after exposure to different substances, including dental materials, toothpastes, cosmetics, foods and medications. To compare the rate of toothpaste allergy between patients with and without cheilitis and to examine the yield of our proposed toothpaste patch test kit for use in patients with cheilitis. A patch test kit containing 11 substances used in toothpastes was formed. The study sample consisted of 44 patients, 24 with cheilitis (study group) and 20 with contact dermatitis but without cheilitis (control group). Eleven patients in the study group (45%) were found to be allergic to toothpaste, compared to only one patient (5%) in the control group (p < .05). The rate of toothpaste allergy among patients with cheilitis might be higher than previously reported. Patch-testing with our toothpaste series is recommended in the evaluation of cheilitis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doebber, I.; Dean, J.; Dominick, J.
2014-03-01
As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft 2 exchangemore » store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).« less
Auto-converging stereo cameras for 3D robotic tele-operation
NASA Astrophysics Data System (ADS)
Edmondson, Richard; Aycock, Todd; Chenault, David
2012-06-01
Polaris Sensor Technologies has developed a Stereovision Upgrade Kit for TALON robot to provide enhanced depth perception to the operator. This kit previously required the TALON Operator Control Unit to be equipped with the optional touchscreen interface to allow for operator control of the camera convergence angle adjustment. This adjustment allowed for optimal camera convergence independent of the distance from the camera to the object being viewed. Polaris has recently improved the performance of the stereo camera by implementing an Automatic Convergence algorithm in a field programmable gate array in the camera assembly. This algorithm uses scene content to automatically adjust the camera convergence angle, freeing the operator to focus on the task rather than adjustment of the vision system. The autoconvergence capability has been demonstrated on both visible zoom cameras and longwave infrared microbolometer stereo pairs.
Adderson, Elisabeth E.; Boudreaux, Jan W.; Cummings, Jessica R.; Pounds, Stanley; Wilson, Deborah A.; Procop, Gary W.; Hayden, Randall T.
2008-01-01
We compared the relative levels of effectiveness of three commercial identification kits and three nucleic acid amplification tests for the identification of coryneform bacteria by testing 50 diverse isolates, including 12 well-characterized control strains and 38 organisms obtained from pediatric oncology patients at our institution. Between 33.3 and 75.0% of control strains were correctly identified to the species level by phenotypic systems or nucleic acid amplification assays. The most sensitive tests were the API Coryne system and amplification and sequencing of the 16S rRNA gene using primers optimized for coryneform bacteria, which correctly identified 9 of 12 control isolates to the species level, and all strains with a high-confidence call were correctly identified. Organisms not correctly identified were species not included in the test kit databases or not producing a pattern of reactions included in kit databases or which could not be differentiated among several genospecies based on reaction patterns. Nucleic acid amplification assays had limited abilities to identify some bacteria to the species level, and comparison of sequence homologies was complicated by the inclusion of allele sequences obtained from uncultivated and uncharacterized strains in databases. The utility of rpoB genotyping was limited by the small number of representative gene sequences that are currently available for comparison. The correlation between identifications produced by different classification systems was poor, particularly for clinical isolates. PMID:18160450
Kajimoto, Noriko; Nakai, Norihiro; Ohkouchi, Mizuka; Hashikura, Yuka; Liu-Kimura, Ning-Ning; Isozaki, Koji; Hirota, Seiichi
2015-01-01
Sporadic mast cell neoplasms and gastrointestinal stromal tumors (GISTs) often have various types of somatic gain-of-function mutations of the c-kit gene which encodes a receptor tyrosine kinase, KIT. Several types of germline gain-of-function mutations of the c-kit gene have been detected in families with multiple GISTs. All three types of model mice for the familial GISTs with germline c-kit gene mutations at exon 11, 13 or 17 show development of GIST, while they are different from each other in skin mast cell number. Skin mast cell number in the model mice with exon 17 mutation was unchanged compared to the corresponding wild-type mice. In the present study, we characterized various types of mast cells derived from the model mice with exon 17 mutation (KIT-Asp818Tyr) corresponding to human familial GIST case with human KIT-Asp820Tyr to clarify the role of the c-kit gene mutation in mast cells. Bone marrow-derived cultured mast cells (BMMCs) derived from wild-type mice, heterozygotes and homozygotes were used for the experiments. Immortalized BMMCs, designated as IMC-G4 cells, derived from BMMCs of a homozygote during long-term culture were also used. Ultrastructure, histamine contents, proliferation profiles and phosphorylation of various signaling molecules in those cells were examined. In IMC-G4 cells, presence of additional mutation(s) of the c-kit gene and effect of KIT inhibitors on both KIT autophosphorylation and cell proliferation were also analyzed. We demonstrated that KIT-Asp818Tyr did not affect ultrastructure and proliferation profiles but did histamine contents in BMMCs. IMC-G4 cells had an additional novel c-kit gene mutation of KIT-Tyr421Cys which is considered to induce neoplastic transformation of mouse mast cells and the mutation appeared to be resistant to a KIT inhibitor of imatinib but sensitive to another KIT inhibitor of nilotinib. IMC-G4 cells might be a useful mast cell line to investigate mast cell biology. PMID:26722383
46 CFR 121.710 - First-aid kits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit... kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A...
Bi-objective optimization of a multiple-target active debris removal mission
NASA Astrophysics Data System (ADS)
Bérend, Nicolas; Olive, Xavier
2016-05-01
The increasing number of space debris in Low-Earth Orbit (LEO) raises the question of future Active Debris Removal (ADR) operations. Typical ADR scenarios rely on an Orbital Transfer Vehicle (OTV) using one of the two following disposal strategies: the first one consists in attaching a deorbiting kit, such as a solid rocket booster, to the debris after rendezvous; with the second one, the OTV captures the debris and moves it to a low-perigee disposal orbit. For multiple-target ADR scenarios, the design of such a mission is very complex, as it involves two optimization levels: one for the space debris sequence, and a second one for the "elementary" orbit transfer strategy from a released debris to the next one in the sequence. This problem can be seen as a Time-Dependant Traveling Salesman Problem (TDTSP) with two objective functions to minimize: the total mission duration and the total propellant consumption. In order to efficiently solve this problem, ONERA has designed, under CNES contract, TOPAS (Tool for Optimal Planning of ADR Sequence), a tool that implements a Branch & Bound method developed in previous work together with a dedicated algorithm for optimizing the "elementary" orbit transfer. A single run of this tool yields an estimation of the Pareto front of the problem, which exhibits the trade-off between mission duration and propellant consumption. We first detail our solution to cope with the combinatorial explosion of complex ADR scenarios with 10 debris. The key point of this approach is to define the orbit transfer strategy through a small set of parameters, allowing an acceptable compromise between the quality of the optimum solution and the calculation cost. Then we present optimization results obtained for various 10 debris removal scenarios involving a 15-ton OTV, using either the deorbiting kit or the disposal orbit strategy. We show that the advantage of one strategy upon the other depends on the propellant margin, the maximum duration allowed for the mission and the orbit inclination domain. For high inclination orbits near 98 deg, the disposal orbit strategy is more appropriate for short duration missions, while the deorbiting kit strategy ensures a better propellant margin. Conversely, for lower inclination orbits near 65 deg, the deorbiting kit strategy appears to be the only possible with a 10 debris set. We eventually explain the consistency of these results with regards to astrodynamics.
Tranberg, Mette; Bech, Bodil Hammer; Blaakær, Jan; Jensen, Jørgen Skov; Svanholm, Hans; Andersen, Berit
2016-11-03
The effectiveness of cervical cancer screening programs is challenged by suboptimal participation and coverage. Offering cervico-vaginal self-sampling for human papillomavirus testing (HPV self-sampling) to non-participants can increase screening participation. However, the effect varies substantially among studies, especially depending on the approach used to offer HPV self-sampling. The present trial evaluates the effect on participation in an organized screening program of a HPV self-sampling kit mailed directly to the home of the woman or mailed to the woman's home on demand only, compared with the standard second reminder for regular screening. The CHOiCE trial is a parallel, randomized, controlled, open-label trial. It will include 9327 women aged 30-64 years who are living in the Central Denmark Region and who have not participated in cervical cancer screening after an invitation and one reminder. The women will be equally randomized into three arms: 1) Directly mailed a second reminder including a HPV self-sampling kit; 2) Mailed a second reminder offering a HPV self-sampling kit, to be ordered by e-mail, text message, phone, or through a webpage; and 3) Mailed a second reminder for a practitioner-collected sample (control group). The primary outcome will be the proportion of women in the intervention groups who participate by returning their HPV self-sampling kit or have a practitioner-collected sample compared with the proportion of women who have a practitioner-collected sample in the control group at 90 and 180 days after mail out of the second reminders. Per-protocol and intention-to-treat analyses will be performed. The secondary outcome will be the proportion of women with a positive HPV self-collected sample who attend follow-up testing at 30, 60, or 90 days after mail out of the results. The CHOiCE trial will provide strong and important evidence allowing us to determine if and how HPV self-sampling can be used to increase participation in cervical cancer screening. This trial therefore has the potential to improve prevention and reduce the number of deaths caused by cervical cancer. Current Controlled Trials NCT02680262 . Registered 10 February 2016.
Genetic lineage tracing identifies in situ Kit-expressing cardiomyocytes
Liu, Qiaozhen; Yang, Rui; Huang, Xiuzhen; Zhang, Hui; He, Lingjuan; Zhang, Libo; Tian, Xueying; Nie, Yu; Hu, Shengshou; Yan, Yan; Zhang, Li; Qiao, Zengyong; Wang, Qing-Dong; Lui, Kathy O; Zhou, Bin
2016-01-01
Cardiac cells marked by c-Kit or Kit, dubbed cardiac stem cells (CSCs), are in clinical trials to investigate their ability to stimulate cardiac regeneration and repair. These studies were initially motivated by the purported cardiogenic activity of these cells. Recent lineage tracing studies using Kit promoter to drive expression of the inducible Cre recombinase showed that these CSCs had highly limited cardiogenic activity, inadequate to support efficient cardiac repair. Here we reassess the lineage tracing data by investigating the identity of cells immediately after Cre labeling. Our instant lineage tracing approach identifies Kit-expressing cardiomyocytes, which are labeled immediately after tamoxifen induction. In combination with long-term lineage tracing experiments, these data reveal that the large majority of long-term labeled cardiomyocytes are pre-existing Kit-expressing cardiomyocytes rather than cardiomyocytes formed de novo from CSCs. This study presents a new interpretation for the contribution of Kit+ cells to cardiomyocytes and shows that Kit genetic lineage tracing over-estimates the cardiogenic activity of Kit+ CSCs. PMID:26634606
Obata, Yuuki; Toyoshima, Shota; Wakamatsu, Ei; Suzuki, Shunichi; Ogawa, Shuhei; Esumi, Hiroyasu; Abe, Ryo
2014-01-01
Kit is a receptor-type tyrosine kinase found on the plasma membrane. It can transform mast cells through activating mutations. Here, we show that a mutant Kit from neoplastic mast cells from mice, Kit(D814Y), is permanently active and allows cells to proliferate autonomously. It does so by activating two signalling pathways from different intracellular compartments. Mutant Kit from the cell surface accumulates on endolysosomes through clathrin-mediated endocytosis, which requires Kit’s kinase activity. Kit(D814Y) is constitutively associated with phosphatidylinositol 3-kinase, but the complex activates Akt only on the cytoplasmic surface of endolysosomes. It resists destruction because it is under-ubiquitinated. Kit(D814Y) also appears in the endoplasmic reticulum soon after biosynthesis, and there, can activate STAT5 aberrantly. These mechanisms of oncogenic signalling are also seen in rat and human mast cell leukemia cells. Thus, oncogenic Kit signalling occurs from different intracellular compartments, and the mutation acts by altering Kit trafficking as well as activation. PMID:25493654
Structural Basis for Activation of the Receptor Tyrosine Kinase KIT by Stem Cell Factor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuzawa,S.; Opatowsky, Y.; Zhang, Z.
2007-01-01
Stem Cell Factor (SCF) initiates its multiple cellular responses by binding to the ectodomain of KIT, resulting in tyrosine kinase activation. We describe the crystal structure of the entire ectodomain of KIT before and after SCF stimulation. The structures show that KIT dimerization is driven by SCF binding whose sole role is to bring two KIT molecules together. Receptor dimerization is followed by conformational changes that enable lateral interactions between membrane proximal Ig-like domains D4 and D5 of two KIT molecules. Experiments with cultured cells show that KIT activation is compromised by point mutations in amino acids critical for D4-D4more » interaction. Moreover, a variety of oncogenic mutations are mapped to the D5-D5 interface. Since key hallmarks of KIT structures, ligand-induced receptor dimerization, and the critical residues in the D4-D4 interface, are conserved in other receptors, the mechanism of KIT stimulation unveiled in this report may apply for other receptor activation.« less
Stability of Dosage Forms in the Pharmaceutical Payload Aboard Space Missions
NASA Technical Reports Server (NTRS)
Du, Brian J.; Daniels, Vernie; Boyd, Jason L.; Crady, Camille; Satterfield, Rick; Younker, Diane R.; Putcha, Lakshmi
2009-01-01
Efficacious pharmaceuticals with adequate shelf lives are essential for successful space medical operations. Stability of pharmaceuticals, therefore, is of paramount importance for assuring the health and wellness of astronauts on future space exploration missions. Unique physical and environmental factors of space missions may contribute to the instability of pharmaceuticals, e.g., radiation, humidity and temperature variations. Degradation of pharmaceutical formulations can result in inadequate efficacy and/or untoward toxic effects, which could compromise astronaut safety and health. Methods: Four identical pharmaceutical payload kits containing 31 medications in different dosage forms (liquid, tablet, capsule, ointment and suppository) were transported to the International Space Station aboard the Space Shuttle (STS-121). One of the 4 kits was stored on the Shuttle and the other 3 were stored on the International Space Station (ISS) for return to Earth at 6-month interval aboard a pre-designated Shuttle flight for each kit. The kit stored on the Shuttle was returned to Earth aboard STS-121 and 2 kits from ISS were returned on STS 117 and STS-122. Results: Analysis of standard physical and chemical parameters of degradation was completed for pharmaceuticals returned by STS-121 after14 days, STS - 117 after11 months and STS 122 after 19 months storage aboard ISS. Analysis of all flight samples along with ground-based matching controls was completed and results were compiled. Conclusion: Evaluation of results from the shuttle (1) and ISS increments (2) indicate that the number of formulations degraded in space increased with duration of storage in space and was higher in space compared to their ground-based counterparts. Rate of degradation for some of the formulations tested was faster in space than on Earth. Additionally, some of the formulations included in the medical kits were unstable, more so in space than on the ground. These results indicate that the space flight environment may adversely affect the shelf life of pharmaceuticals aboard space missions.
Da Silva Figueiredo Celestino Gomes, Priscila; Panel, Nicolas; Laine, Elodie; Pascutti, Pedro Geraldo; Solary, Eric; Tchertanov, Luba
2014-01-01
The colony stimulating factor-1 receptor (CSF-1R) and the stem cell factor receptor KIT, type III receptor tyrosine kinases (RTKs), are important mediators of signal transduction. The normal functions of these receptors can be compromised by gain-of-function mutations associated with different physiopatological impacts. Whereas KIT D816V/H mutation is a well-characterized oncogenic event and principal cause of systemic mastocytosis, the homologous CSF-1R D802V has not been identified in human cancers. The KIT D816V oncogenic mutation triggers resistance to the RTK inhibitor Imatinib used as first line treatment against chronic myeloid leukemia and gastrointestinal tumors. CSF-1R is also sensitive to Imatinib and this sensitivity is altered by mutation D802V. Previous in silico characterization of the D816V mutation in KIT evidenced that the mutation caused a structure reorganization of the juxtamembrane region (JMR) and facilitated its departure from the kinase domain (KD). In this study, we showed that the equivalent CSF-1R D802V mutation does not promote such structural effects on the JMR despite of a reduction on some key H-bonds interactions controlling the JMR binding to the KD. In addition, this mutation disrupts the allosteric communication between two essential regulatory fragments of the receptors, the JMR and the A-loop. Nevertheless, the mutation-induced shift towards an active conformation observed in KIT D816V is not observed in CSF-1R D802V. The distinct impact of equivalent mutation in two homologous RTKs could be associated with the sequence difference between both receptors in the native form, particularly in the JMR region. A local mutation-induced perturbation on the A-loop structure observed in both receptors indicates the stabilization of an inactive non-inhibited form, which Imatinib cannot bind. PMID:24828813
Fang, Ruiqi; Tian, Panliang; Yang, Xianfeng
2018-01-01
The development of efficient encapsulation strategies has attracted intense interest for preparing highly active and stable heterogeneous metal catalysts. However, issues related to low loadings, costly precursors and complex synthesis processes restrict their potential applications. Herein, we report a novel and general strategy to encapsulate various ultrafine metal-oxides nanoparticles (NPs) into the mesoporous KIT-6. The synthesis is facile, which only involves self-assembly of a metal–organic framework (MOF) precursor in the silica mesopores and a subsequent calcination process to transform the MOF into metal-oxide NPs. After the controlled calcination, the metal-oxide NPs produced from MOF decomposition are exclusively confined and uniformly distributed in the mesopores of KIT-6 with high metal loadings. Benefitting from the encapsulation effects, as-synthesized Co@KIT-6 materials exhibit superior catalytic activity and recycling stability in biomass-derived HMF oxidation under mild reaction conditions. PMID:29675231
He, Yi; Zeng, Hui-Zhi; Yu, Yang; Zhang, Jia-Shu; Duan, Xingping; Zeng, Xiao-Na; Gong, Feng-Tao; Liu, Qi; Yang, Bo
2017-09-01
We investigated whether prostate fibrosis was associated with urinary dysfunction in chronic prostatitis (CP) and whether resveratrol improved urinary dysfunction and the underlying molecular mechanism. Rat model of CP was established via subcutaneous injections of DPT vaccine and subsequently treated with resveratrol. Bladder pressure and volume tests investigated the effect of resveratrol on urinary dysfunction in CP rats. Western blotting and immunohistochemical staining examined the expression level of C-kit/SCF and TGF-β/Wnt/β-catenin. Compared to the control group, the maximum capacity of the bladder, residual urine volume and maximum voiding pressure, the activity of C-kit/SCF and TGF-β/Wnt/β-catenin pathways were increased significantly in the CP group. Resveratrol treatment significantly improved these factors. CP induced significantly prostate fibrosis, which exhibits a close relationship with urinary dysfunction. Resveratrol improved fibrosis, which may be associated with the suppression of C-kit/SCF and TGF-β/Wnt/β-catenin pathway. Copyright © 2017 Elsevier B.V. All rights reserved.
Diagnostic performance of the "MESACUP anti-Skin profile TEST".
Horváth, Orsolya N; Varga, Rita; Kaneda, Makoto; Schmidt, Enno; Ruzicka, Thomas; Sárdy, Miklós
2016-01-01
The "MESACUP anti-Skin profile TEST" is a new, commercially available ELISA kit to detect circulating IgG autoantibodies against desmoglein 1, desmoglein 3, BP180, BP230, and type VII collagen, both simultaneously and more rapidly than previous assays. The aim of this study was to evaluate the diagnostic accuracy of this kit for the diagnosis of pemphigus foliaceus, pemphigus vulgaris, bullous pemphigoid and epidermolysis bullosa acquisita. Dual-centre retrospective study in which 138 patients with autoimmune blistering diseases were compared to 40 controls Using the MESACUP anti-Skin profile TEST, both sensitivities and specificities for desmoglein 1, desmoglein 3, BP180, BP230, and type VII collagen autoantibodies were similar to those obtained using previous, specific ELISA systems and 88% of the results were concordant without any significant difference. The MESACUP anti-Skin profile TEST had a similar performance to previously produced ELISA systems. The novel kit can be used for rapid diagnosis of most common autoimmune blistering diseases and is especially suitable for identifying overlapping disorders.
A biotic video game smart phone kit for formal and informal biophysics education
NASA Astrophysics Data System (ADS)
Kim, Honesty; Lee, Seung Ah; Riedel-Kruse, Ingmar
2015-03-01
Novel ways for formal and informal biophysics education are important. We present a low-cost biotic game design kit that incorporates microbial organisms into an interactive gaming experience: A 3D-printable microscope containing four LEDs controlled by a joystick enable human players to provide directional light stimuli to the motile single-celled organism Euglena gracilis. These cellular behaviors are displayed on the integrated smart phone. Real time cell-tracking couples these cells into interactive biotic video game play, i.e., the human player steers Euglena to play soccer with virtual balls and goals. The player's learning curve in mastering this fun game is intrinsically coupled to develop a deeper knowledge about Euglena's cell morphology and the biophysics of its phototactic behavior. This kit is dual educational - via construction and via play - and it provides an engaging theme for a formal biophysics devices class as well as to be presented in informal outreach activities; its low cost and open soft- and hardware should enable wide adoption.
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Effect of planecta and ROSE™ on the frequency characteristics of blood pressure-transducer kits.
Fujiwara, Shigeki; Kawakubo, Yoshifumi; Mori, Satoshi; Tachihara, Keiichi; Toyoguchi, Izumi; Yokoyama, Takeshi
2015-12-01
Pressure-transducer kits have frequency characteristics such as natural frequency and damping coefficient, which affect the monitoring accuracy. The aim of the present study was to investigate the effect of planecta ports and a damping device (ROSE™, Argon Medical Devices, TX, USA) on the frequency characteristics of pressure-transducer kits. The FloTrac sensor kit (Edwards Lifesciences, CA, USA) and the DTXplus transducer kit (Argon Medical Devices) were prepared with planecta ports, and their frequency characteristics were tested with or without ROSE™. The natural frequency and damping coefficient of each kit were obtained using frequency characteristics analysis software and evaluated by plotting them on the Gardner's chart. By inserting a planecta port, the natural frequency markedly decreased in both the FloTrac sensor kit (from 40 to 22 Hz) and the DTXplus transducer kit (from 35 to 22 Hz). In both kits with one planecta port, the damping coefficient markedly increased by insertion of ROSE™ from 0.2 to 0.5, optimising frequency characteristics. In both kits with two planecta ports, however, the natural frequency decreased from 22 to 12 Hz. The damping coefficient increased from 0.2 to 0.8 by insertion of ROSE™; however, optimisation was not achieved even by ROSE™ insertion. Planecta ports decrease the natural frequency of the kit. ROSE™ is useful to optimise the frequency characteristics in the kits without or with one planecta port. However, optimisation is difficult with two or more planecta ports, even with the ROSE™ device.
KIT Mutations Are Common in Testicular Seminomas
Kemmer, Kathleen; Corless, Christopher L.; Fletcher, Jonathan A.; McGreevey, Laura; Haley, Andrea; Griffith, Diana; Cummings, Oscar W.; Wait, Cecily; Town, Ajia; Heinrich, Michael C.
2004-01-01
Expression of KIT tyrosine kinase is critical for normal germ cell development and is observed in the majority of seminomas. Activating mutations in KIT are common in gastrointestinal stromal tumors and mastocytosis. In this study we examined the frequency and spectrum of KIT mutations in 54 testicular seminomas, 1 ovarian dysgerminoma and 37 non-seminomatous germ cell tumors (NSGCT). Fourteen seminomas (25.9%) contained exon 17 point mutations including D816V (6 cases), D816H (3 cases), Y823D (2 cases), and single examples of Y823C, N822K, and T801I. No KIT mutations were found in the ovarian dysgerminoma or the NSGCTs. In transient transfection assays, mutant isoforms D816V, D816H, Y823D, and N822K were constitutively phosphorylated in the absence of the natural ligand for KIT, stem cell factor (SCF). In contrast, activation of T801I and wild-type KIT required SCF. Mutants N822K and Y823D were inhibited by imatinib mesylate (Gleevec, previously STI571) whereas D816V and D816H were both resistant to imatinib mesylate. Biochemical evidence of KIT activation, as assessed by KIT phosphorylation and KIT association with phosphatidylinositol (PI) 3-kinase in tumor cell lysates, was largely confined to seminomas with a genomic KIT mutation. These findings suggest that activating KIT mutations may contribute to tumorigenesis in a subset of seminomas, but are not involved in NSGCT. PMID:14695343
FES kinase participates in KIT-ligand induced chemotaxis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voisset, Edwige, E-mail: Edwige.Voisset@inserm.fr; Institut Paoli-Calmettes, Marseille; Universite de la Mediterranee, Aix-Marseille II
2010-02-26
FES is a cytoplasmic tyrosine kinase activated by several membrane receptors, originally identified as a viral oncogene product. We have recently identified FES as a crucial effector of oncogenic KIT mutant receptor. However, FES implication in wild-type KIT receptor function was not addressed. We report here that FES interacts with KIT and is phosphorylated following activation by its ligand SCF. Unlike in the context of oncogenic KIT mutant, FES is not involved in wild-type KIT proliferation signal, or in cell adhesion. Instead, FES is required for SCF-induced chemotaxis. In conclusion, FES kinase is a mediator of wild-type KIT signalling implicatedmore » in cell migration.« less
KIT pathway alterations in mucosal melanomas of the vulva and other sites.
Omholt, Katarina; Grafström, Eva; Kanter-Lewensohn, Lena; Hansson, Johan; Ragnarsson-Olding, Boel K
2011-06-15
A significant proportion of mucosal melanomas contain alterations in KIT. The aim of this study was to characterize the pattern of KIT, NRAS, and BRAF mutations in mucosal melanomas at specific sites and to assess activation of the KIT downstream RAF/MEK/extracellular signal-regulated kinase (ERK) and phosphoinositide 3-kinase (PI3K)/AKT pathways in mucosal melanoma specimens. Seventy-one primary mucosal melanomas from various sites were studied. Mutation analysis was done by DNA sequencing. Expression of KIT, phosphorylated (p)-ERK, and p-AKT was evaluated by immunohistochemistry. KIT mutations were detected in 35% (8 of 23) of vulvar, 9% (2 of 22) of anorectal, 7% (1 of 14) of nasal cavity, and 20% (1 of 5) of penile melanomas. No KIT mutations were found in 7 vaginal melanomas. The difference in KIT mutation frequency between vulvar and nonvulvar cases was statistically significant (P = 0.014). The overall frequencies of NRAS and BRAF mutations were 10% and 6%, respectively. Notably, vaginal melanomas showed a NRAS mutation rate of 43%. KIT gene amplification (≥4 copies), as assessed by quantitative real-time PCR, was observed in 19% of cases. KIT expression was associated with KIT mutation status (P < 0.001) and was more common in vulvar than nonvulvar tumors (P = 0.016). Expression of p-ERK and p-AKT was observed in 42% and 59% of tumors, respectively, and occurred irrespective of KIT/NRAS/BRAF mutation status. NRAS mutation was associated with worse overall survival in univariate analysis. Results show that KIT mutations are more common in vulvar melanomas than other types of mucosal melanomas and that both the RAF/MEK/ERK and PI3K/AKT pathways are activated in mucosal melanoma specimens. ©2011 AACR.
Khatiwoda, Prasana; Proeschold-Bell, Rae Jean; Meade, Christina S; Park, Lawrence P; Proescholdbell, Scott
2018-01-01
BACKGROUND Naloxone-an opioid antagonist that reverses the effects of opioids-is increasingly being distributed in non-medical settings. We sought to identify the facilitators of, and barriers to, opioid users using naloxone kits in North Carolina. METHODS In 2015, we administered a 15-item survey to a convenience sample of 100 treatment seekers at 4 methadone/buprenorphine Medication Assisted Therapy (MAT) clinics in North Carolina. RESULTS Seventy-four percent of participants reported having ever gotten a naloxone kit; this percentage was higher for females (81%) than males (63%) ( P = .06). The primary reason given for not having a kit was not knowing where to get one. Only 6% had heard of kits from the media and only 5% received one from a medical provider. Among kit recipients, 56% of both females and males reported mostly or sometimes carrying the kit, with additional participants reporting always. Reasons for not carrying a kit were no longer being around drugs, forgetting it, and the kit being too large. Men discussed the difficulties of carrying the naloxone kits, which are currently too large to fit in a pocket. Ninety-four percent of naloxone users reported intending to call emergency services in case of an overdose emergency. LIMITATIONS Study limitations included a small sample, participants limited to MAT clinics, and a predominantly white sample. CONCLUSIONS MAT treatment seekers reported a willingness to carry and use naloxone kits. Education, outreach, media, and medical providers need to promote naloxone kits. A smaller kit may increase the likelihood of men carrying one. ©2018 by the North Carolina Institute of Medicine and The Duke Endowment. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nobuhisa, Ikuo; Ohtsu, Naoki; Okada, Seiji
The aorta-gonad-mesonephros (AGM) region is a primary source of definitive hematopoietic cells in the midgestation mouse embryo. In cultures of dispersed AGM regions, adherent cells containing endothelial cells are observed first, and then non-adherent hematopoietic cells are produced. Here we report on the characterization of hematopoietic cells that emerge in the AGM culture. Based on the expression profiles of CD45 and c-Kit, we defined three cell populations: CD45{sup low} c-Kit{sup +} cells that had the ability to form hematopoietic cell colonies in methylcellulose media and in co-cultures with stromal cells; CD45{sup low} c-Kit{sup -} cells that showed a granulocyte morphology;more » CD45{sup high} c-Kit{sup low/-} that exhibited a macrophage morphology. In co-cultures of OP9 stromal cells and freshly prepared AGM cultures, CD45{sup low} c-Kit{sup +} cells from the AGM culture had the abilities to reproduce CD45{sup low} c-Kit{sup +} cells and differentiate into CD45{sup low} c-Kit{sup -} and CD45{sup high} c-Kit{sup low/-} cells, whereas CD45{sup low} c-Kit{sup -} and CD45{sup high} c-Kit{sup low/-} did not produce CD45{sup low} c-Kit{sup +} cells. Furthermore, CD45{sup low} c-Kit{sup +} cells displayed a long-term repopulating activity in adult hematopoietic tissue when transplanted into the liver of irradiated newborn mice. These results indicate that CD45{sup low} c-Kit{sup +} cells from the AGM culture have the potential to reconstitute multi-lineage hematopoietic cells.« less
Evaluation of four commercial quantitative real-time PCR kits with inhibited and degraded samples.
Holmes, Amy S; Houston, Rachel; Elwick, Kyleen; Gangitano, David; Hughes-Stamm, Sheree
2018-05-01
DNA quantification is a vital step in forensic DNA analysis to determine the optimal input amount for DNA typing. A quantitative real-time polymerase chain reaction (qPCR) assay that can predict DNA degradation or inhibitors present in the sample prior to DNA amplification could aid forensic laboratories in creating a more streamlined and efficient workflow. This study compares the results from four commercial qPCR kits: (1) Investigator® Quantiplex® Pro Kit, (2) Quantifiler® Trio DNA Quantification Kit, (3) PowerQuant® System, and (4) InnoQuant® HY with high molecular weight DNA, low template samples, degraded samples, and DNA spiked with various inhibitors.The results of this study indicate that all kits were comparable in accurately predicting quantities of high quality DNA down to the sub-picogram level. However, the InnoQuant(R) HY kit showed the highest precision across the DNA concentration range tested in this study. In addition, all kits performed similarly with low concentrations of forensically relevant PCR inhibitors. However, in general, the Investigator® Quantiplex® Pro Kit was the most tolerant kit to inhibitors and provided the most accurate quantification results with higher concentrations of inhibitors (except with salt). PowerQuant® and InnoQuant® HY were the most sensitive to inhibitors, but they did indicate significant levels of PCR inhibition. When quantifying degraded samples, each kit provided different degradation indices (DI), with Investigator® Quantiplex® Pro indicating the largest DI and Quantifiler® Trio indicating the smallest DI. When the qPCR kits were paired with their respective STR kit to genotype highly degraded samples, the Investigator® 24plex QS and GlobalFiler® kits generated more complete profiles when the small target concentrations were used for calculating input amount.
Foda, Abd Al-Rahman Mohammad; Mohamed, Mie Ali
2015-10-01
c-KIT and DOG-1 are 2 highly expressed proteins in gastrointestinal stromal tumors. Few studies had investigated c-KIT, but not DOG-1, expression in colorectal carcinoma (CRC). This study aims to investigate expressions of c-KIT and DOG-1 in colorectal mucinous carcinoma and nonmucinous carcinoma using manual tissue microarray technique. In this work, we studied tumor tissue specimens from 150 patients with colorectal mucinous (MA) and nonmucinous adenocarcinoma (NMA). High-density manual tissue microarrays were constructed using modified mechanical pencil tip technique, and immunohistochemistry for c-KIT and DOG-1 was done. We found that aberrant c-KIT expression was detected in 12 cases (8%); 6 cases (4%) showed strong expression. Aberrant DOG-1 expression was detected in 15 cases (10%); among them, only 4 cases (2.7%) showed strong expression. Nonmucinous adenocarcinoma showed a significantly high expression of c-KIT, but not DOG-1, than MA. Aberrant c-KIT and DOG-1 expressions were significantly unrelated but were associated with excessive microscopic abscess formation. Neither c-KIT nor DOG-1 expression showed a significant impact on disease-free survival or overall survival. In conclusion, aberrant c-KIT and DOG-1 expressions in CRC are rare events, either in NMA or MA. Nonmucinous adenocarcinoma showed a significantly higher expression of c-KIT, but not DOG-1, than MA. The expressions of both in CRC are significantly unrelated but are associated with microscopic abscess formation. Neither c-KIT nor DOG-1 expression showed a significant impact on disease-free survival or overall survival. So, c-KIT and DOG-1 immunostaining is not a cost-effective method of identifying patients with CRC who may benefit from treatment with tyrosine kinase inhibitors. Copyright © 2015 Elsevier Inc. All rights reserved.
Molecular Alterations of KIT Oncogene in Gliomas
Gomes, Ana L.; Reis-Filho, Jorge S.; Lopes, José M.; Martinho, Olga; Lambros, Maryou B. K.; Martins, Albino; Schmitt, Fernando; Pardal, Fernando; Reis, Rui M.
2007-01-01
Gliomas are the most common and devastating primary brain tumours. Despite therapeutic advances, the majority of gliomas do not respond either to chemo or radiotherapy. KIT, a class III receptor tyrosine kinase (RTK), is frequently involved in tumourigenic processes. Currently, KIT constitutes an attractive therapeutic target. In the present study we assessed the frequency of KIT overexpression in gliomas and investigated the genetic mechanisms underlying KIT overexpression. KIT (CD117) immunohistochemistry was performed in a series of 179 gliomas of various grades. KIT activating gene mutations (exons 9, 11, 13 and 17) and gene amplification analysis, as defined by chromogenic in situ hybridization (CISH) and quantitative real-time PCR (qRT-PCR) were performed in CD117 positive cases. Tumour cell immunopositivity was detected in 15.6% (28/179) of cases, namely in 25% (1/4) of pilocytic astrocytomas, 25% (5/20) of diffuse astrocytomas, 20% (1/5) of anaplastic astrocytomas, 19.5% (15/77) of glioblastomas and one third (3/9) of anaplastic oligoastrocytomas. Only 5.7% (2/35) of anaplastic oligodendrogliomas showed CD117 immunoreactivity. No association was found between tumour CD117 overexpression and patient survival. In addition, we also observed CD117 overexpression in endothelial cells, which varied from 0–22.2% of cases, being more frequent in high-grade lesions. No KIT activating mutations were identified. Interestingly, CISH and/or qRT-PCR analysis revealed the presence of KIT gene amplification in 6 glioblastomas and 2 anaplastic oligoastrocytomas, corresponding to 33% (8/24) of CD117 positive cases. In conclusion, our results demonstrate that KIT gene amplification rather than gene mutation is a common genetic mechanism underlying KIT expression in subset of malignant gliomas. Further studies are warranted to determine whether glioma patients exhibiting KIT overexpression and KIT gene amplification may benefit from therapy with anti-KIT RTK inhibitors. PMID:17726262
Kalinsky, Kevin; Lee, Sandra; Rubin, Krista M; Lawrence, Donald P; Iafrarte, Anthony J; Borger, Darell R; Margolin, Kim A; Leitao, Mario M; Tarhini, Ahmad A; Koon, Henry B; Pecora, Andrew L; Jaslowski, Anthony J; Cohen, Gary I; Kuzel, Timothy M; Lao, Christopher D; Kirkwood, John M
2017-07-15
KIT-directed tyrosine kinase inhibitors such as imatinib have demonstrated benefits in KIT-mutant (KIT+) mucosal, acral, vulvovaginal, and chronically sun-damaged (CSD) melanoma. Dasatinib has superior preclinical activity in comparison with other tyrosine kinase inhibitors against cells with the most common KIT mutation, exon 11 L576P . The ECOG-ACRIN E2607 trial assessed dasatinib in patients with these melanoma subtypes. Patients received 70 mg of oral dasatinib twice daily. The primary objective for this 2-stage phase 2 trial was response rate. Stage I was open to KIT+ and wild-type KIT (KIT-) mucosal, acral, and CSD melanoma (n = 57). Stage II accrued only KIT+ tumors (n = 30). To enrich the trial for KIT+ tumors, vulvovaginal melanoma was added, and CSD melanoma was removed from eligibility. Secondary objectives included progression-free survival (PFS), overall survival (OS), and safety. From May 2009 to December 2010, the first stage enrolled 57 patients. Among the evaluable patients, 3 of 51 (5.9%) achieved a partial response: all were KIT-. Stage II closed early because of slow accrual (November 2011 to December 2015). In stage II, 4 of 22 evaluable patients (18.2%) had a partial response; the median duration was 4.2 months. The median PFS was 2.1 months (n = 73; 95% confidence interval [CI], 1.5-2.9 months). The median OS was 7.5 months (95% CI, 6.0-11.9 months). In exploratory analyses, no differences were seen in PFS or OS with the KIT status or subtype. Dasatinib was discontinued because of adverse events in 9 of 75 patients (12%). The dasatinib response rate among KIT+ melanoma patients was low. In view of its clinical activity, it is recommended that imatinib remain the KIT tyrosine kinase inhibitor of choice for unresectable KIT+ melanoma. Cancer 2017;123:2688-97. © 2017 American Cancer Society. © 2017 American Cancer Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nobuhisa, Ikuo, E-mail: nobuhisa.scr@mri.tmd.ac.jp; Department of Cell Fate Modulation, Institute of Molecular Embryology and Genetics/Graduate School of Pharmaceutical Sciences, Kumamoto University, Kumamoto, 860-0811; Yamasaki, Shoutarou
Long-term reconstituting hematopoietic stem cells first arise from the aorta of the aorta-gonad-mesonephros (AGM) region in a mouse embryo. We have previously reported that in cultures of the dispersed AGM region, CD45{sup low}c-Kit{sup +} cells possess the ability to reconstitute multilineage hematopoietic cells, but investigations are needed to show that this is not a cultured artifact and to clarify when and how this population is present. Based on the expression profile of CD45 and c-Kit in freshly dissociated AGM cells from embryonic day 9.5 (E9.5) to E12.5 and aorta cells in the AGM from E13.5 to E15.5, we defined sixmore » cell populations (CD45{sup -}c-Kit{sup -}, CD45{sup -}c-Kit{sup low}, CD45{sup -}c-Kit{sup high}, CD45{sup low}c-Kit{sup high}, CD45{sup high}c-Kit{sup high}, and CD45{sup high}c-Kit{sup very} {sup low}). Among these six populations, CD45{sup low}c-Kit{sup high} cells were most able to form hematopoietic cell colonies, but their ability decreased after E11.5 and was undetectable at E13.5 and later. The CD45{sup low}c-Kit{sup high} cells showed multipotency in vitro. We demonstrated further enrichment of hematopoietic activity in the Hoechst dye-effluxing side population among the CD45{sup low}c-Kit{sup high} cells. Here, we determined that CD45{sup low}c-Kit{sup high} cells arise from the lateral plate mesoderm using embryonic stem cell-derived differentiation system. In conclusion, CD45{sup low}c-Kit{sup high} cells are the major hematopoietic cells of mouse AGM.« less
Final results of the Space Exposed Experiment Developed for Students (SEEDS) P-0004-2
NASA Technical Reports Server (NTRS)
Grigsby, Doris K.
1992-01-01
Space Exposed Experiment Developed for Students (SEEDS), resulted in the distribution of over 132,000 SEED kits in 1990. The kits contained Rutger's tomato seeds that had flown on the Long Duration Exposure Facility (LDEF) as well as seeds that had been stored in a climate controlled warehouse for the same period of time. Students compared germination and growth rate characteristics of the two seeds groups and returned data to NASA for analysis. The scientific information gained was valuable as students shared the excitement of taking part in a national project. Of greater importance was the subsequent interest generated in science education.
Bone-induced c-kit expression in prostate cancer: a driver of intraosseous tumor growth
Mainetti, Leandro E.; Zhe, Xiaoning; Diedrich, Jonathan; Saliganan, Allen D.; Cho, Won Jin; Cher, Michael L.; Heath, Elisabeth; Fridman, Rafael; Kim, Hyeong-Reh Choi; Bonfil, R. Daniel
2014-01-01
Loss of BRCA2 function stimulates prostate cancer (PCa) cell invasion and is associated with more aggressive and metastatic tumors in PCa patients. Concurrently, the receptor tyrosine kinase c-kit is highly expressed in skeletal metastases of PCa patients and induced in PCa cells placed into the bone microenvironment in experimental models. However, the precise requirement of c-kit for intraosseous growth of PCa and its relation to BRCA2 expression remain unexplored. Here, we show that c-kit expression promotes migration and invasion of PCa cells. Alongside, we found that c-kit expression in PCa cells parallels BRCA2 downregulation. Gene rescue experiments with human BRCA2 transgene in c-kit-transfected PCa cells resulted in reduction of c-kit protein expression and migration and invasion, suggesting a functional significance of BRCA2 downregulation by c-kit. The inverse association between c-kit and BRCA2 gene expressions in PCa cells was confirmed using laser capture microdissection in experimental intraosseous tumors and bone metastases of PCa patients. Inhibition of bone-induced c-kit expression in PCa cells transduced with lentiviral short hairpin RNA reduced intraosseous tumor incidence and growth. Overall, our results provide evidence of a novel pathway that links bone-induced c-kit expression in PCa cells to BRCA2 downregulation and supports bone metastasis. PMID:24798488
Factors for C-Kit Expression in Cardiac Outgrowth Cells and Human Heart Tissue.
Matsushita, Satoshi; Minematsu, Kazuo; Yamamoto, Taira; Inaba, Hirotaka; Kuwaki, Kenji; Shimada, Akie; Yokoyama, Yasutaka; Amano, Atsushi
2017-12-12
We determined the factors associated with the expression of c-kit in the heart and the proliferation of c-kit-positive (c-kit pos ) cardiac stem cells among the outgrowth cells cultured from human cardiac explants.Samples of the right atrium (RA), left atrium (LA), and left ventricle obtained from patients during open-heart surgery were processed for cell culture of outgrowth cells and tissue analysis. The total number of growing cells and the population of c-kit pos cells were measured and compared with c-kit expression in native tissues and characteristics of the patients according to the region of the heart.We analyzed 452 samples from 334 patients. Atrial fibrillation (AF) in the patients reduced the number of outgrowth cells from the RA and LA, and aging was a co-factor for the LA. The c-kit pos population from the RA was associated with serum brain natriuretic peptide (BNP). C-kit expression in native tissue was also associated with BNP expression. However, we observed no relationship in expression between outgrowth cells and native tissue. In addition, the RA tissue provided the highest number of c-kit pos cells, and the left ventricle provided the lowest.C-kit was weakly expressed in response to damage. In addition, no correlation between outgrowth cells and native tissue was found for c-kit expression.
Obata, Yuuki; Horikawa, Keita; Shiina, Isamu; Takahashi, Tsuyoshi; Murata, Takatsugu; Tasaki, Yasutaka; Suzuki, Kyohei; Yonekura, Keita; Esumi, Hiroyasu; Nishida, Toshirou; Abe, Ryo
2018-02-28
Most gastrointestinal stromal tumours (GISTs) are caused by constitutively active mutations in Kit tyrosine kinase. The drug imatinib, a specific Kit inhibitor, improves the prognosis of metastatic GIST patients, but these patients become resistant to the drug by acquiring secondary mutations in the Kit kinase domain. We recently reported that a Kit mutant causes oncogenic signals only on the Golgi apparatus in GISTs. In this study, we show that in GIST, 2-methylcoprophilinamide (M-COPA, also known as "AMF-26"), an inhibitor of biosynthetic protein trafficking from the endoplasmic reticulum (ER) to the Golgi, suppresses Kit autophosphorylation at Y703/Y721/Y730/Y936, resulting in blockade of oncogenic signalling. Results of our M-COPA treatment assay show that Kit Y703/Y730/Y936 in the ER are dephosphorylated by protein tyrosine phosphatases (PTPs), thus the ER-retained Kit is unable to activate downstream molecules. ER-localized Kit Y721 is not phosphorylated, but not due to PTPs. Importantly, M-COPA can inhibit the activation of the Kit kinase domain mutant, resulting in suppression of imatinib-resistant GIST proliferation. Our study demonstrates that Kit autophosphorylation is spatio-temporally regulated and may offer a new strategy for treating imatinib-resistant GISTs. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1982-01-01
On middeck port side, Pilot Overmyer, looks down at freefloating object. On his left, attached to port side wall, are a dessert package, a prepackaged meal, control panel ML86B, and water dispenser kit with water gun.
Levitation Kits Demonstrate Superconductivity.
ERIC Educational Resources Information Center
Worthy, Ward
1987-01-01
Describes the "Project 1-2-3" levitation kit used to demonstrate superconductivity. Summarizes the materials included in the kit. Discusses the effect demonstrated and gives details on how to obtain kits. Gives an overview of the documentation that is included. (CW)
NASA Astrophysics Data System (ADS)
2012-01-01
WE RECOMMEND Air swimmers Helium balloon swims like a fish Their Arrows will Darken the Sun: The Evolution and Science of Ballistics Ballistics book hits the spot Physics Experiments for your Bag Handy experiments for your lessons Quantum Physics for Poets Book shows the economic importance of physics SEP colour wheel kit Wheels investigate colour theory SEP colour mixing kit Cheap colour mixing kit uses red, green and blue LEDs iHandy Level iPhone app superbly measures angles Photonics Explorer kit Free optics kit given to schools WORTH A LOOK DrDAQ DrDAQ software gets an upgrade WEB WATCH Websites show range of physics
FUNCTIONAL DEREGULATION OF KIT: LINK TO MAST CELL PROLIFERATIVE DISEASES AND OTHER NEOPLASMS
Cruse, Glenn; Metcalfe, Dean D.; Olivera, Ana
2014-01-01
SYNOPSIS Signaling through the receptor tyrosine kinase KIT mediates differentiation, proliferation and survival of hematopoietic precursor cells and mast cells. Constitutive KIT signaling due to somatic point mutations in c-Kit is an important occurrence in the development of mast cell proliferation disorders and other hematological malignancies. In this review, we discuss the common gain-of-function mutations found in these malignancies, particularly in mast cell proliferation disorders, and summarize the current understanding of the molecular mechanisms by which transforming point mutations in KIT may affect KIT structure and function and lead to altered downstream signaling and cellular transformation. Drugs targeting KIT have shown mixed success in the treatment of these diseases. A brief overview of the most common KIT inhibitors currently used, the reasons for the varied clinical results of such inhibitors and a discussion of potential new strategies are provided. PMID:24745671
Accelerator controls at CERN: Some converging trends
NASA Astrophysics Data System (ADS)
Kuiper, B.
1990-08-01
CERN's growing services to the high-energy physics community using frozen resources has led to the implementation of "Technical Boards", mandated to assist the management by making recommendations for rationalizations in various technological domains. The Board on Process Control and Electronics for Accelerators, TEBOCO, has emphasized four main lines which might yield economy in resources. First, a common architecture for accelerator controls has been agreed between the three accelerator divisions. Second, a common hardware/software kit has been defined, from which the large majority of future process interfacing may be composed. A support service for this kit is an essential part of the plan. Third, high-level protocols have been developed for standardizing access to process devices. They derive from agreed standard models of the devices and involve a standard control message. This should ease application development and mobility of equipment. Fourth, a common software engineering methodology and a commercial package of application development tools have been adopted. Some rationalization in the field of the man-machine interface and in matters of synchronization is also under way.
EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations
NASA Technical Reports Server (NTRS)
Rucker, Michelle A.; Hood, Drew; Walker, Mary; Venkateswaran, Kasthuri J.; Schuerger, Andrew C.
2018-01-01
When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.
Pharmacists' views on and experiences with bowel cancer screening kits in Auckland, New Zealand.
Martini, Nataly; Basdew, Kamlika; Kammona, Ala; Shen, Amy; Taylor, Caragh; McIntosh, Timothy R; Barnes, Joanne
2014-08-01
To explore the views of New Zealand pharmacists on bowel cancer screening, particularly with regards to faecal occult blood testing (FOBT) kits, self-perceived knowledge on FOBT kits and barriers, motivators and experiences with selling and counselling consumers with respect to FOBT kits. Semi-structured interviews were conducted face to face or by telephone with 20 community pharmacists in the Auckland region. Interviews were recorded and transcribed verbatim and data were coded and analysed using NVivo software to identify key themes. Participant pharmacists believed that they were well placed to provide advice on FOBT kits to consumers. Barriers to selling the kits included cost and perceived lack of test sensitivity of the kits, poor consumer demand, pharmacists' lack of training and information, and a belief that selling FOBT kits was outside the pharmacists' scope of practice. Motivators to selling the kits included customer convenience, ease of use, confidence in the kits and embracing new roles for pharmacists. Pharmacists were concerned that use of the kits may increase the burden on the public health system through customer anxiety over test results; however, they agreed that there was a need for bowel cancer screening and awareness and that people concerned about bowel cancer should make visiting their general practitioner a priority. Pharmacists' views were mixed. Pharmacists' training and competence with respect to the provision of bowel cancer kits, and how a bowel cancer screening service can be developed to optimise public health outcomes, need to be addressed. © 2013 Royal Pharmaceutical Society.
Repeatability and validity of a field kit for estimation of cholinesterase in whole blood.
London, L; Thompson, M L; Sacks, S; Fuller, B; Bachmann, O M; Myers, J E
1995-01-01
OBJECTIVES--To evaluate a spectrophotometric field kit (Test-Mate-OP) for repeatability and validity in comparison with reference laboratory methods and to model its anticipated sensitivity and specificity based on these findings. METHODS--76 farm workers between the age of 20 and 55, of whom 30 were pesticide applicators exposed to a range of organophosphates in the preceding 10 days, had blood taken for plasma cholinesterase (PCE) and erythrocyte cholinesterase (ECE) measurement by field kit or laboratory methods. Paired blinded duplicate samples were taken from subgroups in the sample to assess repeatability of laboratory and field kit methods. Field kits were also used to test venous blood in one subgroup. The variance obtained for the field kit tests was then applied to two hypothetical scenarios that used published action guidelines to model the kit's sensitivity and specificity. RESULTS--Repeatability for PCE was much poorer and for ECE slightly poorer than that of laboratory measures. A substantial upward bias for field kit ECE relative to laboratory measurements was found. Sensitivity of the kit to a 40% drop in PCE was 67%, whereas that for ECE was 89%. Specificity of the kit with no change in mean of the population was 100% for ECE and 91% for PCE. CONCLUSION--Field kit ECE estimation seems to be sufficiently repeatable for surveillance activities, whereas PCE does not. Repeatability of both tests seems to be too low for use in epidemiological dose-response investigations. Further research is indicated to characterise the upward bias in ECE estimation on the kit. PMID:7697143
UAF: a generic OPC unified architecture framework
NASA Astrophysics Data System (ADS)
Pessemier, Wim; Deconinck, Geert; Raskin, Gert; Saey, Philippe; Van Winckel, Hans
2012-09-01
As an emerging Service Oriented Architecture (SOA) specically designed for industrial automation and process control, the OPC Unied Architecture specication should be regarded as an attractive candidate for controlling scientic instrumentation. Even though an industry-backed standard such as OPC UA can oer substantial added value to these projects, its inherent complexity poses an important obstacle for adopting the technology. Building OPC UA applications requires considerable eort, even when taking advantage of a COTS Software Development Kit (SDK). The OPC Unied Architecture Framework (UAF) attempts to reduce this burden by introducing an abstraction layer between the SDK and the application code in order to achieve a better separation of the technical and the functional concerns. True to its industrial origin, the primary requirement of the framework is to maintain interoperability by staying close to the standard specications, and by expecting the minimum compliance from other OPC UA servers and clients. UAF can therefore be regarded as a software framework to quickly and comfortably develop and deploy OPC UA-based applications, while remaining compatible to third party OPC UA-compliant toolkits, servers (such as PLCs) and clients (such as SCADA software). In the rst phase, as covered by this paper, only the client-side of UAF has been tackled in order to transparently handle discovery, session management, subscriptions, monitored items etc. We describe the design principles and internal architecture of our open-source software project, the rst results of the framework running at the Mercator Telescope, and we give a preview of the planned server-side implementation.
Designing and Implementing Nervous System Simulations on LEGO Robots
Blustein, Daniel; Rosenthal, Nikolai; Ayers, Joseph
2013-01-01
We present a method to use the commercially available LEGO Mindstorms NXT robotics platform to test systems level neuroscience hypotheses. The first step of the method is to develop a nervous system simulation of specific reflexive behaviors of an appropriate model organism; here we use the American Lobster. Exteroceptive reflexes mediated by decussating (crossing) neural connections can explain an animal's taxis towards or away from a stimulus as described by Braitenberg and are particularly well suited for investigation using the NXT platform.1 The nervous system simulation is programmed using LabVIEW software on the LEGO Mindstorms platform. Once the nervous system is tuned properly, behavioral experiments are run on the robot and on the animal under identical environmental conditions. By controlling the sensory milieu experienced by the specimens, differences in behavioral outputs can be observed. These differences may point to specific deficiencies in the nervous system model and serve to inform the iteration of the model for the particular behavior under study. This method allows for the experimental manipulation of electronic nervous systems and serves as a way to explore neuroscience hypotheses specifically regarding the neurophysiological basis of simple innate reflexive behaviors. The LEGO Mindstorms NXT kit provides an affordable and efficient platform on which to test preliminary biomimetic robot control schemes. The approach is also well suited for the high school classroom to serve as the foundation for a hands-on inquiry-based biorobotics curriculum. PMID:23728477
Satzger, Imke; Küttler, Uta; Völker, Bernward; Schenck, Florian; Kapp, Alexander; Gutzmer, Ralf
2010-01-01
Previously an increased frequency of KIT aberrations in mucosal melanomas was reported, whereas c-KIT in most types of cutaneous melanomas does not appear to be of pathogenetic importance. Imatinib has become the standard of care in other cancers with KIT mutations such as gastrointestinal stromal tumors. Recently 12 cases of metastatic melanoma and KIT-activating mutations have been published to be successfully treated with c-KIT blockers such as imatinib, sunitinib, dasatinib or sorafenib. We report here on one of our patients with KIT-activating mutation in metastatic anal mucosal melanoma, who showed a response to imatinib therapy and summarize the available literature regarding this new therapeutic option. Copyright 2009 S. Karger AG, Basel.
Evaluation of a Commercial Latex Agglutination Test Kit for Cryptococcal Antigen
Kaufman, Leo; Cowart, Glenda; Blumer, Sharon; Stine, Amy; Wood, Ross
1974-01-01
Two dozen Crypto-LA kits for detecting Cryptococcus neoformans capsular polysaccharide antigens were evaluated. Ten kits proved reliable for detecting and titering antigen in clinical materials. Fourteen kits were found to be inadequate. PMID:4596394
miR-137 downregulates c-kit expression in acute myeloid leukemia.
Hu, Yanping; Dong, Xiaolong; Chu, Guoming; Lai, Guangrui; Zhang, Bijun; Wang, Leitong; Zhao, Yanyan
2017-06-01
The oncogene c-kit plays a vital role in the pathogenesis of acute myeloid leukemia (AML). However, the mechanism of microRNAs targeting c-kit in AML has not been determined in detail. Moreover, the role miR-137 in tumor cell proliferation remains controversial. The aim of this work was to verify whether miR-137 targets c-kit and to research the biological effects of restoring miR-137 expression in leukemia cells. We found that miR-137 binds specifically to the 3'-UTR of c-kit and suppresses the expression and activities of c-kit. There is a negative correlation between miR-137 and c-kit expression in both patients and cell lines determined by screening large clinical samples. We found that miR-137 can inhibit proliferation, promote apoptosis, and induce differentiation of c-kit+ AML cells. We determined that miR-137 can participate in the leukemogenesis by regulating c-kit, which could be used as a therapeutic target for acute myeloid leukemia. Copyright © 2017 Elsevier Ltd. All rights reserved.
Verdoodt, F; Jentschke, M; Hillemanns, P; Racey, C S; Snijders, P J F; Arbyn, M
2015-11-01
Population coverage for cervical cancer screening is an important determinant explaining differences in the incidence of cervical cancer between countries. Offering devices for self-sampling has the potential to increase participation of hard-to-reach women. A systematic review and meta-analysis were performed to evaluate the participation after an invitation including a self-sampling device (self-sampling arm) versus an invitation to have a sample taken by a health professional (control arm), sent to under-screened women. Sixteen randomised studies were found eligible. In an intention-to-treat analysis, the pooled participation in the self-sampling arm was 23.6% (95% confidence interval (CI)=20.2-27.3%), when self-sampling kits were sent by mail to all women, versus 10.3% (95% CI=6.2-15.2%) in the control arm (participation difference: 12.6% [95% CI=9.3-15.9]). When women had to opt-in to receive the self-sampling device, as used in three studies, the pooled participation was not higher in the self-sampling compared to the control arm (participation difference: 0.2% [95% CI=-4.5-4.9%]). An increased participation was observed in the self-sampling arm compared to the control arm, if self-sampling kits were sent directly to women at their home address. However, the size of the effect varied substantially among studies. Since participation was similar in both arms when women had to opt-in, future studies are warranted to discern opt-in scenarios that are most acceptable to women. Copyright © 2015 Elsevier Ltd. All rights reserved.
Aoki, Kimiko; Tanaka, Hiroyuki; Ueki, Makoto
2017-08-01
When the tampering of a urine sample is suspected in doping control, personal identification of the sample needs to be determined by short tandem repeat (STR) analysis using DNA. We established a method for extracting DNA from urine samples stored at -20 °C without using any additives or procedures, which is consistent with how samples are required to be managed for doping control. The method, using the Puregene® Blood Core kit followed by NucleoSpin® gDNA Clean-up or NucleoSpin® gDNA Clean-up XS kit, does not need any special instrument and can provide a purified extract with high-quality DNA from up to 40 mL of urine suitable for STR analysis using an AmpFlSTR® Identifiler® PCR amplification kit. Storing urine at -20 °C is detrimental to the stability of DNA. The DNA concentration of preserved urine could not be predicted by specific gravity or creatinine level at the time of urine collection. The DNA concentration of a purified extract (10 μL) was required to be >0.06 ng/μL to ensure a successful STR analysis. Thus, the required extraction volumes of urine preserved for 3-7 years at -20 °C were estimated to be 30 mL and 20 mL to succeed in at least 86% of men and 91% of women, respectively. Considering the long half-life of DNA during long-term preservation, our extraction method is applicable to urine samples stored even for 10 years, which is currently the storage duration allowed (increased from 8 years) before re-examination in doping control. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Psychometric Properties of the Concept Assessment Kit-Conservation.
ERIC Educational Resources Information Center
Lehnert, Linda; And Others
1986-01-01
This study investigated the psychometric properties of the Educational and Industrial Testing Service Concept Assessment Kit-Conservation (EITS Kit). Presented are an overview of the concept of conservation, a description of the EITS Kit, and results of the study. (MT)
Rastawicki, Waldemar; Rokosz, Natalia; Jagielski, Marek
2011-01-01
The Binax and the Biotest urinary antigen kits for detection of L. pneumophila antigen were compared by testing of selected 67 urine samples obtained from EWGLI as reference samples in External Quality Assessment Scheme. Thirty nine were positive with the Binax kit (100% of sensitivity), and 33 were positive with the Biotest (84.6% of sensitivity). The test specificities were 100% for the both kits. It was concluded that the Binax kit was more suitable for the routine diagnosis of Legionella infections than the Biotest kit.
Data on quantification of signaling pathways activated by KIT and PDGFRA mutants.
Bahlawane, Christelle; Schmitz, Martine; Letellier, Elisabeth; Arumugam, Karthik; Nicot, Nathalie; Nazarov, Petr V; Haan, Serge
2016-12-01
The present data are related to the article entitled "Insights into ligand stimulation effects on gastro-intestinal stromal tumors signaling" (C. Bahlawane, M. Schmitz, E. Letellier, K. Arumugam, N. Nicot, P.V. Nazarov, S. Haan, 2016) [1]. Constitutive and ligand-derived signaling pathways mediated by KIT and PDGFRA mutated proteins found in gastrointestinal stromal tumors (GIST) were compared. Expression of mutant proteins was induced by doxycycline in an isogenic background (Hek293 cells). Kit was identified by FACS at the cell surface and found to be quickly degraded or internalized upon SCF stimulation for both Kit Wild type and Kit mutant counterparts. Investigation of the main activated pathways in GIST unraveled a new feature specific for oncogenic KIT mutants, namely their ability to be further activated by Kit ligand, the stem cell factor (scf). We were also able to identify the MAPK pathway as the most prominent target for a common inhibition of PDGFRA and KIT oncogenic signaling. Western blotting and micro-array analysis were applied to analyze the capacities of the mutant to induce an effective STATs response. Among all Kit mutants, only Kit Ex11 deletion mutant was able to elicit an effective STATs response whereas all PDGFRA were able to do so.
Statistical modeling of dental unit water bacterial test kit performance.
Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E
2007-01-01
While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.
[Investigation on the incidence of genital herpes in different professional groups in Qingdao].
Quan, L
1993-10-01
Genital herpes is one of 8 legally reportable sexually transmitted diseases (STD) in China. Using a HSV antigen ELISA kit we detected and typed HSV antigen in 1,148 clinical specimens collected from the genital organs (penis, cervix, vagina and vulva) of 446 men and 702 women in Qindao and divided into 11 different professional and 2 special groups (patients with cervical cancer and pregnant women). The highest positive rate of HSV antigen was found among long-distance transport drivers (48.0%). The second and third high positive rates were among waiters and waitresses in private, restaurants (39.2%) and patients with cervical cancer (38.2%). The positive rates among self-employed retailers and employees in private inns and restaurants were notably higher than those among employees in state-run shops, restaurants and hotels. And, the positive rate among workers was higher than that among peasants. There was no notable difference between the positive rate of HSV antigen among men (24.2%) and that among women (21.5%). But the incidence of HSV-2 infection was much higher than that of HSV-1 infection. The results indicate that some special professional groups have high rates of genital HSV infection. More attention needs to be paid to these special groups in order to control sexually transmitted herpes diseases.
[Forensic Application of HuaxiaTM Platinum Kit].
Wang, Y L; Sheng, X; Li, M; Chen, Y L; Lin, Y; Chen, L Q
2017-04-01
To investigate the genetic polymorphism of 23 autosomal STR loci of Huaxia™ Platinum kit in Chinese Han population, and to evaluate the forensic efficiency of Huaxia™ Platinum kit. A total of 500 unrelated healthy individuals from Han population were genotyped with Huaxia™ Platinum kit. The frequency distribution and the parameter of population genetics of STR loci were analysed statistically. Huaxia™ Platinum kit was compared with other 7 commercial STR kits commonly seen at home and abroad in the number of STR loci, interior label, fluorescent mark, total number of alleles in Ladder and system effectiveness. All the 23 autosomal STR loci were consistent with Hardy-Weinberg equilibrium ( P >0.05). The discrimination power was 0.791 5-0.986 2. The polymorphism information content (PIC) was 0.559 0-0.914 0. The combined discrimination power (CDP) was 1-4.1×10⁻²⁸, while combined probability of paternity exclusion in trio (CPET) and in duo (CPED) were 1-4.1×10⁻¹⁰ and 1-8.4×10⁻⁷, respectively. Compared with other 7 kits, Huaxia™ Platinum kit contained the most number of alleles within the Ladder. All the 23 autosomal STR loci of Huaxia™ Platinum kit with highly polymorphic in Han population can be used for paternity testing and individual identification. Compared with other 7 kits, it appears that Huaxia™ Platinum kit can provide more genetic information. Copyright© by the Editorial Department of Journal of Forensic Medicine
Elevated Apoptosis in the Liver of Dairy Cows with Ketosis.
Du, Xiliang; Chen, Liang; Huang, Dan; Peng, Zhicheng; Zhao, Chenxu; Zhang, Yuming; Zhu, Yiwei; Wang, Zhe; Li, Xinwei; Liu, Guowen
2017-01-01
Dairy cows with ketosis are characterized by oxidative stress and hepatic damage. The aim of this study was to investigate hepatic oxidative stress and the apoptotic status of ketotic cows, as well as the underlying apoptosis pathway. The blood aspartate aminotransferase (AST), alanine aminotransferase (ALT), glutamate dehydrogenase (GLDH) and gamma-glutamyl transferase (GGT) activities and the haptoglobin (HP), serum amyloid A (SAA) and serum apoptotic cytokeratin 18 neo-epitope M30 (CK18 M30) concentrations were determined by commercially available kits and ELISA kits, respectively. Liver histology, TUNEL and Oil red O staining were performed in liver tissue samples. TG contents were measured using an enzymatic kit; Caspase 3 assays were carried out using the Caspase 3 activity assay kit; oxidation and antioxidant markers were measured using biochemical kits; apoptosis pathway were determined by qRT-PCR and western blot. Ketotic cows displayed hepatic fat accumulation. The hepatic malondialdehyde (MDA) content was significantly increased, but the activities of catalase (CAT), superoxide dismutase (SOD) and glutathione peroxidase (GSH-Px) were markedly decreased in ketotic cows compared with control cows, indicating that ketotic cows displayed severe oxidative stress. Significantly higher serum levels of the hepatic damage markers AST, ALT, GGT and GLDH were observed in ketotic cows than in control cows. The blood concentration of the apoptotic marker CK18 M30 and the number of TUNEL-positive cells in the liver of ketotic cows were 1.19- and 2.61-fold, respectively, higher than the values observed in control cows. Besides, Caspase 3 activity was significantly increased in the liver of ketosis cows. Importantly, the levels of phosphorylated c-Jun N-terminal kinase (JNK) and p38 mitogen-activated protein kinase (p38MAPK) were significantly increased but the level of phosphorylated extracellular signal-regulated kinase1/2 (ERK1/2) was markedly decreased, which further promoted tumor protein 53 (p53) expression and inhibited nuclear factor E2-related factor 2 (Nrf2) expression. The apoptosis-related molecules p21, MDM2, Caspase 3, Caspase 9 and Bax were expressed at significantly higher levels in ketotic cows than in healthy cows, whereas the anti-apoptosis molecule Bcl-2 was expressed at significantly lower levels. Based on these results, ketotic cows display severe hepatic oxidative stress. The hepatic MAPK-p53-Nrf2 apoptotic pathway is over induced and partially mediated apoptotic damage in the liver. © 2017 The Author(s). Published by S. Karger AG, Basel.
Commander Lousma adjusts MLR controls on middeck
1982-03-30
STS003-22-127 (22-30 March 1982) --- Astronaut Jack R. Lousma, STS-3 commander, wearing communications kit assembly (assy) mini-headset, adjusts controls on Monodisperse Latex Reactor (MLR) experiment located in forward middeck lockers MF57H and MF57K. To reach MLR support electronics assy controls, Lousma squeezes in between forward lockers and Development Flight Instrument (DFI) unit on starboard bulkhead. Photo credit: NASA
Khuda, Sefat E; Sharma, Girdhari M; Gaines, Dennis; Do, Andrew B; Pereira, Marion; Chang, Michael; Ferguson, Martine; Williams, Kristina M
2016-08-01
Since the number of recalls involving undeclared allergens is commonly associated with bakery and snack foods, we aimed to determine the frequency of egg allergens in a large number of these products using two commercial enzyme-linked immunosorbent assay (ELISA) methods. Samples were chosen that either had no egg identified on the product label or which had an egg precautionary statement. Among all samples, egg protein was detected in 5% of products using a Morinaga (MO) kit and 1% of products using a R-Biopharm (RB) kit. For bakery samples, egg protein was detected in 6% of 363 samples with no precautionary labelling (6% by MO and 1% by RB kit) and 12% of 80 samples which had precautionary labelling. For snack samples, egg protein was detected in 2% of 371 samples with no precautionary labelling (2% by MO and < 1% by RB kit) and 5% of 21 samples which had precautionary labelling. The disagreement rates between two methods were 5.2% for bakery products and 2.6% for snack products. The sample repeatability was at an acceptable level for bakery (< 12.5%) and snack foods (< 7.5%) for each method. The relative standard deviation between test kits was high (103.1%) for bakery foods. Four bakery products without precautionary labelling had a higher level of egg protein per serving compared with the eliciting dose (ED10 of 3.7 mg protein) for egg allergic patients. These results highlight the fact that detection methodology plays a vital role for accurate labelling control and mitigation of risk for egg allergic consumers.
Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano; Bastien, Patrick
2015-01-01
The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. Copyright © 2015, American Society for Microbiology. All Rights Reserved.
Filisetti, Denis; Sterkers, Yvon; Brenier-Pinchart, Marie-Pierre; Cassaing, Sophie; Dalle, Frédéric; Delhaes, Laurence; Pelloux, Hervé; Touafek, Fériel; Varlet-Marie, Emmanuelle; Yera, Hélène; Candolfi, Ermano
2014-01-01
The detection of Toxoplasma gondii in amniotic fluid is an essential tool for the prenatal diagnosis of congenital toxoplasmosis and is currently essentially based on the use of PCR. Although some consensus is emerging, this molecular diagnosis suffers from a lack of standardization and an extreme diversity of laboratory-developed methods. Commercial kits for the detection of T. gondii by PCR were recently developed and offer certain advantages; however, they must be assessed in comparison with optimized reference PCR assays. The present multicentric study aimed to compare the performances of the Bio-Evolution T. gondii detection kit and laboratory-developed PCR assays set up in eight proficient centers in France. The study compared 157 amniotic fluid samples and found concordances of 99% and 100% using 76 T. gondii-infected samples and 81 uninfected samples, respectively. Moreover, taking into account the classification of the European Research Network on Congenital Toxoplasmosis, the overall diagnostic sensitivity of all assays was identical and calculated to be 86% (54/63); specificity was 100% for all assays. Finally, the relative quantification results were in good agreement between the kit and the laboratory-developed assays. The good performances of this commercial kit are probably in part linked to the use of a number of good practices: detection in multiplicate, amplification of the repetitive DNA target rep529, and the use of an internal control for the detection of PCR inhibitors. The only drawbacks noted at the time of the study were the absence of uracil-N-glycosylase and small defects in the reliability of the production of different reagents. PMID:25339393
Sow, Doudou; Dieng, Yémou; Haouchine, Djamal; Niang, Khadim; Niang, Thiane; Sylla, Khadime; Tine, Roger Clément; Ndiaye, Magatte; Ndiaye, Jean Louis; Faye, Babacar; Faye, Omar; Gaye, Oumar; Dieng, Thérèse; Izri, Arezki
2017-09-01
In the context of controlling intestinal parasites, accurate diagnosis is essential. Our objective was to evaluate the performance of new diagnostic kits compared to conventional microscopic methods in identifying intestinal parasites. Faeces collected in rural area in Senegal were subjected to several detection techniques. Thus, the sensitivity, specificity, positive and negative predictive values of new diagnostic techniques were compared to conventional merthiolate-iodine-formalin, conventional Bailenger and modified Ritchie. Furthermore, the kappa coefficient was calculated to evaluate the correlation between the new kit and those of modified Ritchie. Out of the 117 patients examined, 102 presented with a parasite, or prevalence of 87.1%. The Fumouze techniques proved to be as effective as the conventional methods in detecting flagellates and helminths with sensitivities ranging from 97 to 100%. However, conventional techniques were slightly more sensitive in identifying Endolimax nana and Blastocystis hominis . The correlation was nearly perfect (k = 0.83 and 1), respectively between Bailenger Fumouze, Iodesine Fumouze and modified Ritchie in identifying helminths while it was just acceptable (k = 0.27 and 0.28) in identifying B. hominis . The modified Ritchie technique routinely used in our laboratory remains a good diagnostic tool. However, the use of kit techniques was interesting when reading the pellet after concentration and the Colour KOP staining was a considerable contribution to the diagnosis of the vegetative forms. Therefore, it would be interesting to determine the cost of a stool test using Fumouze kit techniques to provide the most cost effective way.
Nguyen, Lam Thanh; Nakaishi, Kazunari; Motojima, Keiko; Ohkawara, Ayako; Minato, Erina; Maruyama, Junki; Hiono, Takahiro; Matsuno, Keita; Okamatsu, Masatoshi; Kimura, Takashi; Takada, Ayato; Kida, Hiroshi; Sakoda, Yoshihiro
2017-01-01
Highly pathogenic avian influenza viruses (HPAIVs) of H5 subtype have persistently caused outbreaks in domestic poultry and wild birds worldwide and sporadically infected humans. Rapid and accurate diagnosis is one of the key strategies for the control of H5 HPAIVs. However, the sensitivity of the diagnosis of H5 HPAIVs has gradually reduced due to extensive antigenic variation during their evolution. Particularly, the previously developed immunochromatographic diagnosis kit for H5 viruses, Linjudge Flu A/H5, exhibits reduced detection of H5 HPAIVs isolated in recent years. In the present study, we established a new advanced H5 rapid immunochromatographic detection kit (New Linjudge Flu A/H5) by a combination of two anti-H5 hemagglutinin monoclonal antibodies, A64/1 previously applied in the Linjudge Flu A/H5 and A32/2, a novel monoclonal antibody generated from a clade 2.3.4.4 H5 HPAIV. The new kit broadly detected all classical and recent H5 influenza viruses and showed a higher specificity and sensitivity than the original Linjudge Flu A/H5 with recently circulating H5 HPAIVs. Furthermore, the applicability of the New Linjudge Flu A/H5 was demonstrated by detecting antigens from the swabs and tissue homogenates of naturally infected birds and experimentally infected chickens with H5N6 HPAIVs belonging to the genetic clade 2.3.4.4. Our study, therefore, can provide an effective point-of-care rapid antigen detection kit for the surveillance of H5 avian influenza viruses and as a prompt countermeasure against the current widespread of the clade 2.3.4.4 H5 HPAIVs in domestic and wild birds.
Haase, B; Rieder, S; Leeb, T
2015-06-01
White spotting phenotypes have been intensively studied in horses, and although similar phenotypes occur in the donkey, little is known about the molecular genetics underlying these patterns in donkeys. White spotting in donkeys can range from only a few white areas to almost complete depigmentation and is characterised by a loss of pigmentation usually progressing from a white spot in the hip area. Completely white-born donkeys are rare, and the phenotype is characterised by the complete absence of pigment resulting in pink skin and a white coat. A dominant mode of inheritance has been demonstrated for spotting in donkeys. Although the mode of inheritance for the completely white phenotype in donkeys is not clear, the phenotype shows similarities to dominant white in horses. As variants in the KIT gene are known to cause a range of white phenotypes in the horse, we investigated the KIT gene as a potential candidate gene for two phenotypes in the donkey, white spotting and white. A mutation analysis of all 21 KIT exons identified a missense variant in exon 4 (c.662A>C; p.Tyr221Ser) present only in a white-born donkey. A second variant affecting a splice donor site (c.1978+2T>A) was found exclusively in donkeys with white spotting. Both variants were absent in 24 solid-coloured controls. To the authors' knowledge, this is the first study investigating genetic mechanisms underlying white phenotypes in donkeys. Our results suggest that two independent KIT alleles are probably responsible for white spotting and white in donkeys. © 2015 Stichting International Foundation for Animal Genetics.
Akin, C; Schwartz, L B; Kitoh, T; Obayashi, H; Worobec, A S; Scott, L M; Metcalfe, D D
2000-08-15
Systemic mastocytosis is a disease of mast cell proliferation that may be associated with hematologic disorders. There are no features on examination that allow the diagnosis of systemic disease, and mast cell-derived mediators, which may be elevated in urine or blood, may also be elevated in individuals with severe allergic disorders. Thus, the diagnosis usually depends on results of bone marrow biopsy. To facilitate evaluation, surrogate markers of the extent and severity of the disease are needed. Because of the association of mastocytosis with hematologic disease, plasma levels were measured for soluble KIT (sKIT) and soluble interleukin-2 receptor alpha chain (sCD25), which are known to be cleaved in part from the mast cell surface and are elevated in some hematologic malignancies. Results revealed that levels of both soluble receptors are increased in systemic mastocytosis. Median plasma sKIT concentrations as expressed by AU/mL (1 AU = 1.4 ng/mL) were as follows: controls, 176 (n = 60); urticaria pigmentosa without systemic involvement, 194 (n = 8); systemic indolent mastocytosis, 511 (n = 30); systemic mastocytosis with an associated hematologic disorder, 1320 (n = 7); aggressive mastocytosis, 3390 (n = 3). Plasma sCD25 levels were elevated in systemic mastocytosis; the highest levels were associated with extensive bone marrow involvement. Levels of sKIT correlated with total tryptase levels, sCD25 levels, and bone marrow pathology. These results demonstrate that sKIT and sCD25 are useful surrogate markers of disease severity in patients with mastocytosis and should aid in diagnosis, in the selection of those needing a bone marrow biopsy, and in the documentation of disease progression. (Blood. 2000;96:1267-1273)
Low-cost field test kits for arsenic detection in water.
Das, Joyati; Sarkar, Priyabrata; Panda, Jigisha; Pal, Priyabrata
2014-01-01
Arsenic, a common contaminant of groundwater, affects human health adversely. According to the World Health Organization (WHO), the maximum recommended contamination level of arsenic in drinking water is 10 μg/L. The purpose of this research was to develop user-friendly kits for detection of arsenic to measure at least up to 10 μg/L in drinking water, so that a preventive measure could be taken. Two different kits for detection of total arsenic in water are reported here. First, the arsenic in drinking water was converted to arsine gas by a strong reducing agent. The arsine produced was then detected by paper strips via generation of color due to reaction with either mercuric bromide (KIT-1) or silver nitrate (KIT-2). These were previously immobilized on the detector strip. The first one gave a yellow color and the second one grey. Both of these kits could detect arsenic contamination within a range of 10 μg/L-250 μg/L. The detection time for both the kits was only 7 min. The kits exhibited excellent performance compared to other kits available in the market with respect to detection time, ease of operation, cost and could be easily handled by a layman. The field trials with these kits gave very satisfactory results. A study on interference revealed that these kits could be used in the presence of 24 common ions present in the arsenic contaminated water. Though the kits were meant for qualitative assay, the results with unknown concentrations of real samples, when compared with atomic absorption spectrophotometer (AAS) were in good agreement as revealed by the t-test.
Immunomagnetic Separation of Cryptosporidium parvum from Source Water Samples of Various Turbidities
Bukhari, Z.; McCuin, R. M.; Fricker, C. R.; Clancy, J. L.
1998-01-01
Immunomagnetic separation (IMS) procedures which specifically capture Cryptosporidium oocysts and have the potential to isolate oocysts from debris have become commercially available. We compared two IMS kits (kit DB [Dynabeads anti-Cryptosporidium; product no. 730.01; Dynal A.S., Oslo, Norway] and kit IC1 [Crypto Scan IMS; product no. R10; Clearwater Diagnostics Company, LLC, Portland, Maine]) and a modification of kit IC1 (kit IC2 [Crypto Scan IMS; product no. R10; Clearwater Diagnostics Company, LLC]) at three turbidity levels (50, 500, and 5,000 nephelometric turbidity units [ntu]) by using water matrices obtained from different geographical locations. In deionized water, kit DB yielded recoveries between 68 and 83%, whereas the recoveries obtained with kits IC1 and IC2 were more variable and ranged from 0.2 to 74.5%. In water matrices with turbidity levels up to 500 ntu, the oocyst recoveries were more variable with kit DB; however, the recoveries were similar to those obtained in deionized water. In contrast, there were notable reductions in oocyst recoveries in the turbid matrices with kits IC1 and IC2, and the highest recovery (8.3%) was obtained with a 50-ntu sample. An examination of the effects of age on oocyst recovery with kit DB revealed that oocysts up to 16 weeks old yielded recoveries similar to the recoveries observed with fresh oocysts. These data indicate that all IMS kits do not perform equally well, and it is important to conduct in-house quality assurance work before a commercially available IMS kit is selected to replace flotation procedures for recovery of Cryptosporidium oocysts. PMID:9797313
Elwick, Kyleen; Mayes, Carrie; Hughes-Stamm, Sheree
2018-05-01
In cases such as mass disasters or missing persons, human remains are challenging to identify as they may be fragmented, burnt, been buried, decomposed, and/or contain inhibitory substances. This study compares the performance of a relatively new STR kit in the US market (Investigator® 24plex QS kit; Qiagen) with the GlobalFiler® PCR Amplification kit (Thermo Fisher Scientific) when genotyping highly inhibited and low level DNA samples. In this study, DNA samples ranging from 1 ng to 7.8 pg were amplified to define the sensitivity of two systems. In addition, DNA (1 ng and 0.1 ng input amounts) was spiked with various concentrations of five inhibitors common to human remains (humic acid, melanin, hematin, collagen, calcium). Furthermore, bone (N = 5) and tissue samples from decomposed human remains (N = 6) were used as mock casework samples for comparative analysis with both STR kits. The data suggest that the GlobalFiler® kit may be slightly more sensitive than the Investigator® kit. On average STR profiles appeared to be more balanced and average peak heights were higher when using the GlobalFiler® kit. However, the data also show that the Investigator® kit may be more tolerant to common PCR inhibitors. While both STR kits showed a decrease in alleles as the inhibitor concentration increased, more complete profiles were obtained when the Investigator® kit was used. Of the 11 bone and decomposed tissue samples tested, 8 resulted in more complete and balanced STR profiles when amplified with the GlobalFiler® kit. Copyright © 2018 Elsevier B.V. All rights reserved.
c-kit expression profile and regulatory factors during spermatogonial stem cell differentiation
2013-01-01
Background It has been proven that c-kit is crucial for proliferation, migration, survival and maturation of spermatogenic cells. A periodic expression of c-kit is observed from primordial germ cells (PGCs) to spermatogenetic stem cells (SSCs), However, the expression profile of c-kit during the entire spermatogenesis process is still unclear. This study aims to reveal and compare c-kit expression profiles in the SSCs before and after the anticipated differentiation, as well as to examine its relationship with retinoic acid (RA) stimulation. Results We have found that there are more than 4 transcripts of c-kit expressed in the cell lines and in the testes. The transcripts can be divided into short and long categories. The long transcripts include the full-length canonical c-kit transcript and the 3′ end short transcript. Short transcripts include the 3.4 kb short transcript and several truncated transcripts (1.9-3.2 kb). In addition, the 3.4 kb transcript (starting from intron 9 and covering exons 10 ~ 21) is discovered to be specifically expressed in the spermatogonia. The extracellular domain of Kit is obtained in the spermatogonia stage, but the intracellular domain (50 kDa) is constantly expressed in both SSCs and spermatogonia. The c-kit expression profiles in the testis and the spermatogonial stem cell lines vary after RA stimulation. The wave-like changes of the quantitative expression pattern of c-kit (increase initially and decrease afterwards) during the induction process are similar to that of the in vivo male germ cell development process. Conclusions There are dynamic transcription and translation changes of c-kit before and after SSCs’ anticipated differentiation and most importantly, RA is a significant upstream regulatory factor for c-kit expression. PMID:24161026
Comparison of lesional skin c-KIT mutations with clinical phenotype in patients with mastocytosis.
Chan, I J; Tharp, M D
2018-06-01
Activating c-KIT mutations cause abnormal mast cell growth and appear to play a role in mastocytosis. However, the correlation of c-KIT mutations with disease phenotypes is poorly characterized. To evaluate the correlation of c-KIT mutations with clinical presentations and laboratory findings. Total cellular RNA was isolated from the skin lesions of 43 adults and 7 children with mastocytosis, and PCR amplicons of cDNA were sequenced for c-KIT mutations. The most common activating mutation, KIT-D816V, was identified in 72% of adults and 57% of children. Additional activating mutations, namely, V560G and the internal tandem duplications (ITDs) 502-503dupAY, were detected in 12% of adults and 8% of children. V560G occurred more commonly in our patients than previously reported, and it appeared to be associated with more advanced disease. Otherwise, the presence or absence of activating mutations did not correlate with skin lesion morphology, disease extent or total serum tryptase levels. Four adults had expression only of wild-type KIT, while two others had expression of a truncated KIT lacking tyrosine kinase activity; yet these patients were clinically indistinguishable from those patients with activating c-KIT mutations. Activating c-KIT mutations exist in a significant portion of patients with mastocytosis, but not all patients showed expression of these mutations. Except for V560G, the presence or absence of activating c-KIT mutations did not predict the extent of disease. These observations suggest that although activating c-KIT mutations are associated with mast cell growth, other genes probably play a role in the cause of mastocytosis. © 2018 British Association of Dermatologists.
40 CFR 59.506 - How do I demonstrate compliance if I manufacture multi-component kits?
Code of Federal Regulations, 2011 CFR
2011-07-01
... multi-component kits as defined in § 59.503, then the Kit PWR must not exceed the Total Reactivity Limit. (b) You must calculate the Kit PWR and the Total Reactivity Limit as follows: (1) KIT PWR = (PWR(1) × W1) + (PWR(2) × W2) +. ...+ (PWR(n) × Wn) (2) Total Reactivity Limit = (RL1 × W1) + (RL2 × W2...
40 CFR 59.506 - How do I demonstrate compliance if I manufacture multi-component kits?
Code of Federal Regulations, 2014 CFR
2014-07-01
... multi-component kits as defined in § 59.503, then the Kit PWR must not exceed the Total Reactivity Limit. (b) You must calculate the Kit PWR and the Total Reactivity Limit as follows: (1) KIT PWR = (PWR(1) × W1) + (PWR(2) × W2) +. ...+ (PWR(n) × Wn) (2) Total Reactivity Limit = (RL1 × W1) + (RL2 × W2...
40 CFR 59.506 - How do I demonstrate compliance if I manufacture multi-component kits?
Code of Federal Regulations, 2012 CFR
2012-07-01
... multi-component kits as defined in § 59.503, then the Kit PWR must not exceed the Total Reactivity Limit. (b) You must calculate the Kit PWR and the Total Reactivity Limit as follows: (1) KIT PWR = (PWR(1) × W1) + (PWR(2) × W2) +. ...+ (PWR(n) × Wn) (2) Total Reactivity Limit = (RL1 × W1) + (RL2 × W2...
40 CFR 59.506 - How do I demonstrate compliance if I manufacture multi-component kits?
Code of Federal Regulations, 2013 CFR
2013-07-01
... multi-component kits as defined in § 59.503, then the Kit PWR must not exceed the Total Reactivity Limit. (b) You must calculate the Kit PWR and the Total Reactivity Limit as follows: (1) KIT PWR = (PWR(1) × W1) + (PWR(2) × W2) +. ...+ (PWR(n) × Wn) (2) Total Reactivity Limit = (RL1 × W1) + (RL2 × W2...
Computational Methods for Feedback Controllers for Aerodynamics Flow Applications
2007-08-15
Iteration #, and y-translation by: »> Fy=[unf(:,8);runA(:,8);runB(:,8);runC(:,8);runD(:,S); runE (:,8)]; >> Oy-[unf(:,23) ;runA(:,23) ;runB(:,23) ;runC(:,23...runD(:,23) ; runE (:,23)]; >> Iter-[unf(:,1);runA(U ,l);runB(:,l);runC(:,l) ;runD(:,l); runE (:,l)]; >> plot(Fy) Cobalt version 4.0 €blso!,,tic,,. ř-21
Mahmoudi, Nagissa; Slater, Greg F; Fulthorpe, Roberta R
2011-08-01
Molecular characterization of the microbial populations of soils and sediments contaminated with polycyclic aromatic hydrocarbons (PAHs) is often a first step in assessing intrinsic biodegradation potential. However, soils are problematic for molecular analysis owing to the presence of organic matter, such as humic acids. Furthermore, the presence of contaminants, such as PAHs, can cause further challenges to DNA extraction, quantification, and amplification. The goal of our study was to compare the effectiveness of four commercial soil DNA extraction kits (UltraClean Soil DNA Isolation kit, PowerSoil DNA Isolation kit, PowerMax Soil DNA Isolation kit, and FastDNA SPIN kit) to extract pure, high-quality bacterial and eukaryotic DNA from PAH-contaminated soils. Six different contaminated soils were used to determine if there were any biases among the kits due to soil properties or level of contamination. Extracted DNA was used as a template for bacterial 16S rDNA and eukaryotic 18S rDNA amplifications, and PCR products were subsequently analyzed using denaturing gel gradient electrophoresis (DGGE). We found that the FastDNA SPIN kit provided significantly higher DNA yields for all soils; however, it also resulted in the highest levels of humic acid contamination. Soil texture and organic carbon content of the soil did not affect the DNA yield of any kit. Moreover, a liquid-liquid extraction of the DNA extracts found no residual PAHs, indicating that all kits were effective at removing contaminants in the extraction process. Although the PowerSoil DNA Isolation kit gave relatively low DNA yields, it provided the highest quality DNA based on successful amplification of both bacterial and eukaryotic DNA for all six soils. DGGE fingerprints among the kits were dramatically different for both bacterial and eukaryotic DNA. The PowerSoil DNA Isolation kit revealed multiple bands for each soil and provided the most consistent DGGE profiles among replicates for both bacterial and eukaryotic DNA.
Brahimi-Adouane, Sabrina; Bachet, Jean-Baptiste; Tabone-Eglinger, Séverine; Subra, Frédéric; Capron, Claude; Blay, Jean-Yves; Emile, Jean-François
2013-06-01
Gain of function mutations of KIT are frequent in some human tumors, and are sensible to tyrosine kinase inhibitors. In most tumors, oncogenic mutations are heterozygous, however most in vitro data of KIT activation have been obtained with hemizygous mutation. This study aimed to investigate the maturation and activation of wild-type (WT) and mutant (M) forms of KIT in hemizygous and heterozygous conditions. WT and two types of exon 11 deletions M forms of human KIT were expressed in NIH3T3 cell lines. Membrane expression of KIT was quantified by flow cytometry. Quantification of glycosylated forms of KIT and phosphorylated forms of AKT and ERK were performed by western blot. Simultaneous activation of WT KIT and treatment with endoplasmic reticulum (ER) inhibitors, tunicamycin or brefeldin A induced a complete inhibition of membrane expression of the 145 kDa form of KIT. By contrast activation or ER inhibitors alone, only partly inhibited this form. ER inhibitors also inhibited KIT activation-dependent phosphorylation of AKT and ERK1/2. Brefeldin A induced a complete down regulation of the 145 kDa form in hemizygous M, and induced an intra-cellular accumulation of the 125 kDa form in WT but not in hemizygous M. Heterozygous cells had glycosylation and response to ER inhibitors patterns more similar to WT than to hemizygous M. Phosphorylated AKT was reduced in hemizygous cells in comparison to WT KIT cells and heterozygous cells, and in the presence of brefeldin A in all cell lines. Effects of ER inhibitors are significantly different in hemizygous and heterozygous mutants. Differences in intra-cellular trafficking of KIT forms result in differences in downstream signaling pathways, and activation of PI3K/AKT pathway appears to be tied to the presence of the mature 145 kDa form of KIT at the membrane surface. Copyright © 2012 Federation of European Biochemical Societies. Published by Elsevier B.V. All rights reserved.
Park, Cheol Keun; Kim, Won Kyu; Kim, Hoguen
2017-10-01
KIT overexpression is frequently observed in adenoid cystic carcinomas (AdCCs), chromophobe renal cell carcinomas (ChRCCs), and gastrointestinal stromal tumours (GISTs). Persistent KIT activation has been reported to be mediated by protein kinase C (PKC)-δ in a subset of colon cancers with wild-type KIT overexpression, and by PKC-θ in GISTs with mutant KIT overexpression. To elucidate the clinical implications of PKC-δ and PKC-θ expression in KIT-expressing tumours, we investigated the expression of KIT, PKC-δ and PKC-θ in AdCCs and ChRCCs in comparison with GISTs. KIT expression, PKC-δ expression and PKC-θ expression were analysed in whole sections from 41 AdCCs, 40 ChRCCs and 56 GISTs by immunohistochemistry. Membranous expression of KIT was found in 34 AdCCs and all ChRCCs, whereas cytoplasmic expression of KIT was found in 46 GISTs. In AdCCs, PKC-δ expression was associated with histological grade (P = 0.049), lymphovascular invasion (P = 0.004), perineural invasion (P = 0.002), and KIT positivity (P = 0.002). PKC-δ positivity was associated with shorter relapse-free survival (RFS) (P = 0.017) and a tendency for there to be shorter overall survival (OS) (P = 0.090) in patients with AdCCs. No clinicopathological associations were observed between PKC-δ and KIT expression in ChRCCs. In GISTs, PKC-θ expression was associated with higher mitotic count (P = 0.011) and high grade according to the modified National Institutes of Health criteria (P < 0.001). PKC-θ positivity was associated with shorter RFS (P = 0.016) and a tendency for there to be shorter OS (P = 0.051) in patients with GISTs. PKC-δ expression is associated with KIT expression and the prognosis of patients with AdCCs, suggesting that PKC-δ may be a potential therapeutic target for AdCCs. © 2017 The Authors. Histopathology published by John Wiley & Sons Ltd.
Activated c-Kit receptor in the heart promotes cardiac repair and regeneration after injury
Di Siena, S; Gimmelli, R; Nori, S L; Barbagallo, F; Campolo, F; Dolci, S; Rossi, P; Venneri, M A; Giannetta, E; Gianfrilli, D; Feigenbaum, L; Lenzi, A; Naro, F; Cianflone, E; Mancuso, T; Torella, D; Isidori, A M; Pellegrini, M
2016-01-01
The role of endogenous c-Kit receptor activation on cardiac cell homeostasis and repair remains largely unexplored. Transgenic mice carrying an activating point mutation (TgD814Y) in the kinase domain of the c-Kit gene were generated. c-KitTgD814Y receptor was expressed in the heart during embryonic development and postnatal life, in a similar timing and expression pattern to that of the endogenous gene, but not in the hematopoietic compartment allowing the study of a cardiac-specific phenotype. c-KitTgD814Y mutation produced a constitutive active c-Kit receptor in cardiac tissue and cells from transgenic mice as demonstrated by the increased phosphorylation of ERK1/2 and AKT, which are the main downstream molecular effectors of c-Kit receptor signaling. In adult transgenic hearts, cardiac morphology, size and total c-Kit+ cardiac cell number was not different compared with wt mice. However, when c-KitTgD814Y mice were subjected to transmural necrotic heart damage by cryoinjury (CI), all transgenic survived, compared with half of wt mice. In the sub-acute phase after CI, transgenic and wt mice showed similar heart damage. However, 9 days after CI, transgenic mice exhibited an increased number of c-Kit+CD31+ endothelial progenitor cells surrounding the necrotic area. At later follow-up, a consistent reduction of fibrotic area, increased capillary density and increased cardiomyocyte replenishment rate (as established by BrdU incorporation) were observed in transgenic compared with wt mice. Consistently, CD45−c-Kit+ cardiac stem cells isolated from transgenic c-KitTgD814Y mice showed an enhanced endothelial and cardiomyocyte differentiation potential compared with cells isolated from the wt. Constitutive activation of c-Kit receptor in mice is associated with an increased cardiac myogenic and vasculogenic reparative potential after injury, with a significant improvement of survival. PMID:27468693
Siemens, Helge; Jackstadt, Rene; Kaller, Markus; Hermeking, Heiko
2013-01-01
The c-Kit receptor tyrosine kinase is commonly over-expressed in different types of cancer. p53 activation is known to result in the down-regulation of c-Kit. However, the underlying mechanism has remained unknown. Here, we show that the p53-induced miR-34 microRNA family mediates repression of c-Kit by p53 via a conserved seed-matching sequence in the c-Kit 3'-UTR. Ectopic miR-34a resulted in a decrease in Erk signaling and transformation, which was dependent on the down-regulation of c-Kit expression. Furthermore, ectopic expression of c-Kit conferred resistance of colorectal cancer (CRC) cells to treatment with 5-fluorouracil (5-FU), whereas ectopic miR-34a sensitized the cells to 5-FU. After stimulation with c-Kit ligand/stem cell factor (SCF) Colo320 CRC cells displayed increased migration/invasion, whereas ectopic miR-34a inhibited SCF-induced migration/invasion. Activation of a conditional c-Kit allele induced several stemness markers in DLD-1 CRC cells. In primary CRC samples elevated c-Kit expression also showed a positive correlation with markers of stemness, such as Lgr5, CD44, OLFM4, BMI-1 and β-catenin. On the contrary, activation of a conditional miR-34a allele in DLD-1 cells diminished the expression of c-Kit and several stemness markers (CD44, Lgr5 and BMI-1) and suppressed sphere formation. MiR-34a also suppressed enhanced sphere-formation after exposure to SCF. Taken together, our data establish c-Kit as a new direct target of miR-34 and demonstrate that this regulation interferes with several c-Kit-mediated effects on cancer cells. Therefore, this regulation may be potentially relevant for future diagnostic and therapeutic approaches. PMID:24009080
DEVELOPMENT OF AN IDENTIFICATION KIT FOR SPILLED HAZARDOUS MATERIALS
The Chemical Systems Laboratory (CSL) has developed a field kit to identify spilled hazardous materials in inland waters and on the ground. The Hazardous Materials Spills Identification Kit is a two-component kit consisting of an inverter/shortwave UV lamp unit for photochemical ...
HNU-HANBY PCP IMMUNOASSAY TEST KIT - INNOVATIVE TECHNOLOGY EVALUATION REPORT
The HNU-Hanby pentachlorophenol (PCP) test kit rapidly analyzes for PCP in soil samples. The test kit can only detect those PCP carriers that contain aromatic compounds. The test kit estimates PCP concentrations in soil samples indirectly by measuring petroleum hydrocarbon carrie...
Kandhakumari, Gandhi; Stephen, Selvaraj
2017-01-01
At present, three rapid kits are available globally for the confirmation of Mycobacterium tuberculosis complex (MTBC) in cultures by MPT64 antigen (MPT64 Ag) detection. These include Capilia TB, SD Bioline, and BD MGIT TBc Identification (TBcID). The third kit is yet to be validated in India. We have tested this kit and compared with SD Bioline using conventional tests as gold standard. Seventy-one MTBC (70 M. tuberculosis and one Mycobacterium bovis) and four nontuberculous mycobacteria (NTM) were isolated from 649 clinical specimens in MGIT 960 and/or Lowenstein-Jensen slants (LJ). MPT64 Ag was detected by both TBcID and SD Bioline kits in all the 71 clinical isolates and the reference strain M. tuberculosis H37Rv. All NTM species tested were negative by the two different kits. Thus, TBcID kit showed 100% concordance in terms of sensitivity and specificity. Rapid kits confirm MTBC cultures within 15 min in contrast to several weeks' time required by conventional techniques.
[Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].
Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping
2014-06-01
To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.
Gutierrez, Dario A; Muralidhar, Sathya; Feyerabend, Thorsten B; Herzig, Stephan; Rodewald, Hans-Reimer
2015-05-05
Obesity, insulin resistance, and related pathologies are associated with immune-mediated chronic inflammation. Kit mutant mice are protected from diet-induced obesity and associated co-morbidities, and this phenotype has previously been attributed to their lack of mast cells. We performed a comprehensive metabolic analysis of Kit-dependent Kit(W/Wv) and Kit-independent Cpa3(Cre/+) mast-cell-deficient mouse strains, employing diet-induced or genetic (Lep(Ob/Ob) background) models of obesity. Our results show that mast cell deficiency, in the absence of Kit mutations, plays no role in the regulation of weight gain or insulin resistance. Moreover, we provide evidence that the metabolic phenotype observed in Kit mutant mice, while independent of mast cells, is immune regulated. Our data underscore the value of definitive mast cell deficiency models to conclusively test the involvement of this enigmatic cell in immune-mediated pathologies and identify Kit as a key hematopoietic factor in the pathogenesis of metabolic syndrome. Copyright © 2015 Elsevier Inc. All rights reserved.
Nagata, H; Worobec, A S; Metcalfe, D D
1996-01-01
c-Kit is the receptor for stem cell factor (SCF) and is found on hematopoietic stem cells, mast cells, melanocytes, and germ cells. Aggregation of c-Kit by SCF regulates cell proliferation, differentiation, and survival. In the process of examining c-Kit, a polymorphism in the transmembrane domain of the protooncogene c-Kit was identified. This polymorphism consisted of an A-to-C transversion at nucleotide (nt) 1642, and was deduced to substitute leucine for methionine at codon 541. The frequency of the allele with 'C' at nt 1642 was 0.09 in 64 unrelated subjects. Analysis of a two-generation family with the polymorphism suggested that this polymorphism did not result in disease. This is the first report of a polymorphism in the transmembrane domain of c-Kit, and may be of value in understanding and following the function of c-Kit in normal subjects and in those with other abnormalities of c-Kit.
Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L
2016-07-01
Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®
Cloning and establishment of a line of rats for high levels of voluntary wheel running.
Morishima-Yamato, Masaki; Hisaoka, Fumiko; Shinomiya, Sachiko; Harada, Nagakatsu; Matoba, Hideki; Takahashi, Akira; Nakaya, Yutaka
2005-06-17
We generated an original Wistar line of rats that displayed increased levels of wheel running, which we named SPORTS (Spontaneously-Running-Tokushima-Shikoku). Male SPORTS rats ran voluntarily in a running wheel almost six times longer than male control Wistar rats, established without selection for their running activity. The running phenotype of female SPORTS rats was the same as female control Wistar rats. However, male offspring from the cross-mating between a female SPORTS rat and a male control rat also showed a similar level of hyper-running activity as the original SPORTS line. Compared to control rats, male SPORTS rats had lower levels of mean body weight, abdominal fat and plasma insulin after 4 weeks of running. It is likely that all these beneficial changes observed in the SPORTS rats reflected the increases in glucose disposal we observed in oral glucose tolerance tests carried out on the animals. We also found hyper-running caused a significant increase in skeletal muscle oxidative capacity, measured as the ratio of malate dehydrogenase to phosphofructokinase activity, an index of aerobic metabolism. These results indicate that the SPORTS rat may be a good animal model for determining the mechanisms responsible for up-regulation of running motivation, in addition to investigating changes in nutrient metabolism induced by high intensity exercise.
Pandey, Praveen; Mishra, Anupam; Tripathi, Ashoak Mani; Verma, Veerendra; Trivedi, Ritu; Singh, Hitendra Prakash; Kumar, Sunil; Patel, Brijesh; Singh, Vinay; Pandey, Shivani; Pandey, Amita; Mishra, Subhash Chandra
2017-03-01
An attempt is made to analyze the molecular behavior of juvenile nasopharyngeal angiofibroma (JNA). Case Series METHODS: Quantification of mRNAs expression was undertaken through real-time polymerase chain reaction in JNA (9-24) samples for VEGF-A, basic fibroblast growth factor (b-FGF), platelet-derived growth factor PDGF-A, KIT proto-oncogene receptor tyrosine kinase (c-Kit), Avian myelomatosis viral oncogene homolog (c-Myc), Harvey rat sarcoma viral oncogene homolog (H-Ras), tumor suppressor gene TP53, and androgen receptor and interleukin 6 (IL-6). The β-catenin expression was evaluated by western blot in 16 samples. Nasal polyp was taken as control. A significantly increased (P < 0.01) expression of c-myc, VEGFA, bFGF, PDGFA, c-kit, and TP53 was seen, along with enhanced expression of β-catenin. A massive enhancement of H-Ras expression was seen for the first time. Androgen receptor expression was no different, whereas IL-6 despite showing upregulation trend was not significant. The enhanced expressions of various markers suggest their potential role in JNA. Although the biological significance of c-kit, c-myc, and one of the novel markers H-Ras has yet to be defined, their significant expression may have a therapeutic importance. NA. Laryngoscope, 127:E100-E106, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.
Field determination of PCB in transformer oil. Volume 2. Clor-N-Oil PCB screening test. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, D.J.; Rouse, T.O.; Lynn, T.
1984-10-01
The requirements for handling and disposing of transformer minerals oils containing more than 50 ppM PCB are, by federal regulation, different from those for oils containing lower concentrations. A rapid and simple test to distinguish between samples containing more than or less than this concentration would simplify proper control of transformer oils. This report describes the development of a small disposable test kit that can be used on-site to screen the chlorine content of transformer oils. The kit consists of two soft plastic tubes in which thin walled glass ampules containing premeasured amounts of reagents are broken. The reaction sequencemore » in the kits converts the chlorine in PCB to chloride ion. The color of the liquid in the kit after the last step is blue to purple if the chloride content due to the initial chlorine concentration of the oil is less than 20 ppM. If the chlorine content of the oil is below 20 ppM, the PCB content must be below 50 ppM. The liquid is colorless if the chlorine content is greater than 20 ppM. In this latter case, it is necessary to determine by gas chromatography whether the PCB content is actually greater than 50 ppM or if there is some other source of chlorine in the oil.« less
Pradeep, Jothimani; Ambroise, Stanley; Gunasekaran, Dhandapany
2017-01-01
Introduction Query (Q) fever is an important zoonosis and a cause of concern for humans, due to the potential bioterrorism threat posed by the causative agent, Coxiella burnetii. Because of the danger of contracting the illness, isolation attempts are seldom made. Serological and molecular diagnostic tests are the main option. Aim To study the prevalence of acute Q fever in Puducherry and surrounding districts of Tamil Nadu, India, employing a new commercial Real-Time Polymerase Chain Reaction (RT-PCR) kit and confirming it by the gold standard Immunofluorescence Assay (IFA). Materials and Methods Acute phase blood samples from 72 consecutive febrile patients and 24 healthy individuals were included in this prospective study. DNA was extracted from the buffy coats and preserved at -80°C. Detection of C. burnetii was carried out employing a commercial Real-Time PCR kit. Serum samples were tested for IgM (Phase I+II) and IgG (Phase I+II) by QM-120 and QG-120, Coxiella burnetii IFA Fuller Laboratories, California, USA. Sensitivity, Specificity, Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were calculated keeping IFA as the reference. Results Presumptive diagnosis of acute Q fever was made in two febrile patients by the Genesig Easy kit (2.78%). In addition to these two PCR positive cases, one more patient was positive for both Phase II IgM and Phase II IgG antibodies by the gold standard IFA. All 24 healthy controls were negative for Q fever by both PCR and IFA. The sensitivity, specificity, NPV and PPV for Genesig Easy kit PCR were: 66.67%, 100%, 100% and 98.57 % respectively against IFA as the reference. Conclusion The true prevalence of Q fever in India and other developing countries is poorly understood, owing to the difficulties in the diagnosis of this infection. Since molecular diagnostic tests have good specificity and are mandated for confirmation of single acute samples, validation of commercial Q fever PCR kits is the need of the hour. Genesig Easy kit in our hands was found to be reliable with the moderate sensitivity and high specificity. Performing both PCR (with acute specimens) and IFA (with paired sera) would be ideal for Q fever diagnosis. PMID:29207703
40 CFR 1060.104 - What running loss emission control requirements apply?
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND.... (3) Get an approved Executive Order from the California Air Resources Board showing that your system meets applicable running loss standards in California. (c) If you are subject to both running loss and...
40 CFR 1060.104 - What running loss emission control requirements apply?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND.... (3) Get an approved Executive Order from the California Air Resources Board showing that your system meets applicable running loss standards in California. (c) If you are subject to both running loss and...
40 CFR 1060.104 - What running loss emission control requirements apply?
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND.... (3) Get an approved Executive Order from the California Air Resources Board showing that your system meets applicable running loss standards in California. (c) If you are subject to both running loss and...
40 CFR 1060.104 - What running loss emission control requirements apply?
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EVAPORATIVE EMISSIONS FROM NEW AND IN-USE NONROAD AND.... (3) Get an approved Executive Order from the California Air Resources Board showing that your system meets applicable running loss standards in California. (c) If you are subject to both running loss and...
KIT gene mutations and patterns of protein expression in mucosal and acral melanoma.
Abu-Abed, Suzan; Pennell, Nancy; Petrella, Teresa; Wright, Frances; Seth, Arun; Hanna, Wedad
2012-01-01
Recently characterized KIT (CD117) gene mutations have revealed new pathways involved in melanoma pathogenesis. In particular, certain subtypes harbor mutations similar to those observed in gastrointestinal stromal tumors, which are sensitive to treatment with tyrosine kinase inhibitors. The purpose of this study was to characterize KIT gene mutations and patterns of protein expression in mucosal and acral melanoma. Formalin-fixed, paraffin-embedded tissues were retrieved from our archives. Histologic assessment included routine hematoxylin-eosin stains and immunohistochemical staining for KIT. Genomic DNA was used for polymerase chain reaction-based amplification of exons 11 and 13. We identified 59 acral and mucosal melanoma cases, of which 78% showed variable levels of KIT expression. Sequencing of exons 11 and 13 was completed on all cases, and 4 (6.8%) mutant cases were isolated. We successfully optimized conditions for the detection of KIT mutations and showed that 8.6% of mucosal and 4.2% of acral melanoma cases at our institution harbor KIT mutations; all mutant cases showed strong, diffuse KIT protein expression. Our case series represents the first Canadian study to characterize KIT gene mutations and patterns of protein expression in acral and mucosal melanoma.
Conditional Deletion of Kit in Melanocytes: White Spotting Phenotype Is Cell Autonomous.
Aoki, Hitomi; Tomita, Hiroyuki; Hara, Akira; Kunisada, Takahiro
2015-07-01
It is well established that cell-intrinsic signaling through the receptor tyrosine kinase KIT is critical for the development of neural crest-derived melanocytes. Nevertheless, it is not entirely clear whether Kit acts exclusively in a melanocyte-autonomous manner or in addition indirectly through other cell types. To address this question in vivo, we generated a targeted allele of Kit that allowed for CRE recombinase-mediated deletion of the transmembrane domain of KIT. Mice carrying one copy of the targeted allele and expressing CRE under the melanoblast/melanocyte-specific tyrosinase promoter exhibited a white spotting phenotype that was even more extensive compared with that found in mice heterozygous for a Kit-null allele. This phenotype is unlikely the result of sequestration of KIT ligand by neighboring cells or by potentially secreted forms of KIT because the spotting phenotype could not be rescued by overexpression of KITL. Likewise, overexpression of endothelin-3 or hepatocyte growth factor was unable to rescue melanocytes in these mice. Although the severity of the observed phenotype remains to be explained, the findings indicate that melanocyte-selective impairment of Kit is sufficient to interfere with normal melanocyte development.
The usefulness of c-Kit in the immunohistochemical assessment of melanocytic lesions
Pilloni, L.; Bianco, P.; Difelice, E.; Cabras, S.; Castellanos, M.E.; Atzori, L.; Ferreli, C.; Mulas, P.; Nemolato, S.; Faa, G.
2011-01-01
C-Kit (CD117), the receptor for the stem cell factor, a growth factor for melanocyte migration and proliferation, has shown differential immunostaining in various benign and malignant melanocytic lesions. The purpose of this study is to compare c-Kit immunostaining in benign nevi and in primary and metastatic malignant melanomas, to determine whether c-Kit can aid in the differential diagnosis of these lesions. c-Kit immunostaining was performed in 60 cases of pigmented lesions, including 39 benign nevi (5 blue nevi, 5 intra-dermal nevi, 3 junctional nevi, 15 cases of primary compound nevus, 11 cases of Spitz nevus), 18 cases of primary malignant melanoma and 3 cases of metastatic melanoma. The vast majority of nevi and melanomas examined in this study were positive for c-Kit, with minimal differences between benign and malignant lesions. C-Kit cytoplasmatic immunoreactivity in the intraepidermal proliferating nevus cells, was detected in benign pigmented lesions as well as in malignant melanoma, increasing with the age of patients (P=0.007) in both groups. The patient’s age at presentation appeared to be the variable able to cluster benign and malignant pigmented lesions. The percentage of c-Kit positive intraepidermal nevus cells was better associated with age despite other variables (P=0.014). The intensity and percentage of c-Kit positivity in the proliferating nevus cells in the dermis was significantly increased in malignant melanocytic lesions (P=0.015 and P=0.008) compared to benign lesions (compound melanocytic nevi, Spitz nevi, intradermal nevi, blue nevi). Immunostaning for c-Kit in metastatic melanomas was negative. Interestingly in two cases of melanoma occurring on a pre-existent nevus, the melanoma tumor cells showed strong cytoplasmatic and membranous positivity for c-kit, in contrast with the absence of any immunoreactivity in pre-existent intradermal nevus cells. C-Kit does not appear to be a strong immunohistochemical marker for distinguishing melanoma from melanocytic nevi, if we consider c-Kit expression in intraepidermal proliferating cells. The c-Kit expression in proliferating melanocytes in the dermis could help in the differential diagnosis between a superficial spreading melanoma (with dermis invasion) and a compound nevus or an intradermal nevus. Finally, c-Kit could be a good diagnostic tool for distinguishing benign compound nevi from malignant melanocytic lesions with dermis invasion and to differentiate metastatic melanoma from primary melanoma. PMID:22193299
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 1 2012-10-01 2012-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 1 2011-10-01 2011-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...
DEMONSTRATION BULLETIN: HNU-HANBY PCP IMMUNOASSAY TEST KIT - HNU - SYSTEMS, INC.
The HNU-Hanby test kit rapidly analyzes for petroleum hydrocarbons in soil and water samples. The test kit can be used to estimate pentachlorophenol (PCP) concentrations in samples when the carrier solvent is a petroleum hydrocarbon. The test kit estimates PCP concentrations in ...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 1 2013-10-01 2013-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 1 2014-10-01 2014-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...
Mast cells promote melanoma colonization of lungs.
Öhrvik, Helena; Grujic, Mirjana; Waern, Ida; Gustafson, Ann-Marie; Ernst, Nancy; Roers, Axel; Hartmann, Karin; Pejler, Gunnar
2016-10-18
Mast cells have been implicated in malignant processes, mainly through clinical correlative studies and by experiments performed using animals lacking mast cells due to defective c-kit signaling. However, mast cell-deficient mouse models based on c-kit defects have recently been questioned for their relevance. Here we addressed the effect of mast cells in a tumor setting by using transgenic Mcpt5-Cre+ R-DTA+ mice, in which the deficiency of mast cells is independent of c-kit defects. Melanoma cells (B16.F10) were administered either subcutaneously or intravenously into Mcpt5-Cre+ R-DTA+ mice or Mcpt5-Cre- R-DTA+ littermate controls, followed by the assessment of formed tumors. In the subcutaneous model, mast cells were abundant in the tumor stroma of control mice but were absent in Mcpt5-Cre+ R-DTA+ mice. However, the absence of mast cells did not affect tumor size. In contrast, after intravenous administration of B16.F10 cells, melanoma colonization of the lungs was markedly reduced in Mcpt5-Cre+ R-DTA+ vs. Mcpt5-Cre- R-DTA+ animals. Decreased melanoma colonization of the lungs in Mcpt5-Cre+ R-DTA+ animals was accompanied by increased inflammatory cell recruitment into the bronchoalveolar lavage fluid, suggesting that mast cells suppress inflammation in this setting. Further, qPCR analysis revealed significant alterations in the expression of Twist and E-cadherin in lungs of Mcpt5-Cre+ R-DTA+ vs. control Mcpt5-Cre- R-DTA+ animals, suggesting an impact of mast cells on epithelial-mesenchymal transition. In conclusion, this study reveals that mast cells promote melanoma colonization of the lung.