Sample records for sac alert area

  1. SAC ALERT AREA AND FLIGHT LINE BUILDINGS, LOOKING TOWARD RESERVE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SAC ALERT AREA AND FLIGHT LINE BUILDINGS, LOOKING TOWARD RESERVE FIRE TEAM FACILITY (BUILDING 3001) (CENTER). VIEW TO SOUTHEAST. - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY

  2. 11. SAC command center, main operations area, underground structure, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. SAC command center, main operations area, underground structure, building 501, undated - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  3. 9. SAC command center, main operations area, underground structure, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. SAC command center, main operations area, underground structure, building 501, undated - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  4. 10. SAC command center, main operations area, underground structure, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. SAC command center, main operations area, underground structure, building 501, circa 1980 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  5. 12. SAC command center, main operations area, underground structure, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. SAC command center, main operations area, underground structure, building 501, circa 1960 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  6. Providing accurate near real-time fire alerts for Protected Areas through NASA FIRMS: Opportunities and Challenges

    NASA Astrophysics Data System (ADS)

    Ilavajhala, S.; Davies, D.; Schmaltz, J. E.; Wong, M.; Murphy, K. J.

    2013-12-01

    The NASA Fire Information for Resource Management System (FIRMS) is at the forefront of providing global near real-time (NRT) MODIS thermal anomalies / hotspot location data to end-users . FIRMS serves the data via an interactive Web GIS named Web Fire Mapper, downloads of NRT active fire, archive data downloads for MODIS hotspots dating back to 1999 and a hotspot email alert system The FIRMS Email Alerts system has been successfully alerting users of fires in their area of interest in near real-time and/or via daily and weekly email summaries, with an option to receive MODIS hotspot data as a text file (CSV) attachment. Currently, there are more than 7000 email alert subscriptions from more than 100 countries. Specifically, the email alerts system is designed to generate and send an email alert for any region or area on the globe, with a special focus on providing alerts for protected areas worldwide. For many protected areas, email alerts are particularly useful for early fire detection, monitoring on going fires, as well as allocating resources to protect wildlife and natural resources of particular value. For protected areas, FIRMS uses the World Database on Protected Areas (WDPA) supplied by United Nations Environment Program - World Conservation Monitoring Centre (UNEP-WCMC). Maintaining the most up-to-date, accurate boundary geometry for the protected areas for the email alerts is a challenge as the WDPA is continuously updated due to changing boundaries, merging or delisting of certain protected areas. Because of this dynamic nature of the protected areas database, the FIRMS protected areas database is frequently out-of-date with the most current version of WDPA database. To maintain the most up-to-date boundary information for protected areas and to be in compliance with the WDPA terms and conditions, FIRMS needs to constantly update its database of protected areas. Currently, FIRMS strives to keep its database up to date by downloading the most recent

  7. Recrystallization Behavior in SAC305 and SAC305 + 3.0POSS Solder Joints Under Thermal Shock

    NASA Astrophysics Data System (ADS)

    Han, Jing; Gu, Penghao; Ma, Limin; Guo, Fu; Liu, Jianping

    2018-04-01

    Sn-3.0Ag-0.5Cu (SAC305) and SAC305 + 3.0 polyhedral oligomeric silsesquioxanes (POSS) ball grid array (BGA) assemblies have been prepared, observed, and subjected to thermal shock. The microstructure and grain orientation evolution of the solder joints located at the same position of the package were characterized by scanning electron microscopy and electron backscattering diffraction, respectively. The results showed that the microstructure of the solder joints was refined by addition of POSS particles. In addition, compared with the single-grained or tricrystal joints normally observed in SAC305 BGA solder joints, the frequency of single-grained as-reflowed SAC305 + 3.0POSS BGA joints was greatly reduced, and the solder joints were typically composed of multicrystals with orientations separated by high-angle grain boundaries. These multicrystal joints appear to be obtained by dominant tricrystals or double tricrystals with deviation of the preferred [110] and [1\\bar{1}0] growth directions of Sn dendrites in Sn-Ag-based solder alloys during solidification from the melt. After 928 thermal shock cycles, the SAC305 solder joint had large-area recrystallization and cracks in contrast to the SAC305 + 3.0POSS solder joint located at the same position of the package, indicating that addition of POSS to SAC305 solder joints may contribute to postponement of recrystallization and subsequent crack initiation and propagation along recrystallized grain boundaries by pinning grain boundaries and movement of dislocations. This finding also confirms the double tricrystal solidification twinning nucleation behavior in Pb-free solder joints.

  8. Investigation of corrosion on SAC 305, SAC 0307 and SAC 0307-0.03 P-0.005 Ni solder paste alloys in simulated body fluid (SBF)

    NASA Astrophysics Data System (ADS)

    Sarveswaran, C.; Salleh, Emee Marina; Jalar, A.; Samsudin, Z.; Ali, M. Yusuf Tura; Ani, F. Che; Othman, N. K.

    2017-05-01

    The electrochemical migration (ECM) behaviour of SAC 305, SAC 0307 and SAC 0307-0.03 P-0.005 Ni has been investigated by using simulated body fluid (SBF) solution. Water drop test (WDT) was performed to compute the mean-time-to-failure (MTTF) of each sample while its electrical behaviour was examined using four-point probe test station. The microstructure of each solder paste alloy was observed using field emission scanning electron microscope (FESEM) with energy dispersive X-ray spectroscopy (EDX) to analyse the elemental composition of the solder alloy. The MTTF result shows that SAC 305 has the fastest time-to-failure (TTF) due to short circuit. The corrosion susceptibility of SAC 305 was higher compared with SAC 0307-0.03P-0.005Ni. This was because of the influence of dopant phosphorus and nickel incorporation in the SAC 0307-0.03 P-0.005 Ni. The four point-probe test station reveals that SAC 305 is a good electric conductor whilst SAC 0307-0.03 P-0.005 Ni is a poor electric conductor. The rate of dendritic growth was influenced by the alloying element of the solder. Therefore, SAC 0307-0.03 P-0.005 Ni have a good corrosion resistance in SBF medium.

  9. Quantitative analysis in spontaneous canine anal sac gland adenomas and carcinomas.

    PubMed

    Simeonov, Radostin; Simeonova, Galina

    2008-12-01

    Stained cytological specimens from 7 canine anal sac gland adenomas and 11 canine anal sac gland carcinomas were analyzed by computer-assisted nuclear morphometry. In each case, the nuclei of at least 100 neoplastic cells were measured, and the mean nuclear area (MNA), mean nuclear perimeter (MNP), mean nuclear diameter (MND) and nuclear roundness (NR) were calculated. The study aimed to evaluate (1) the possibility of using nuclear cytomorphometry as an auxiliary diagnostic method to differentiate between canine anal sac gland adenomas and adenocarcinomas, and (2) the prognostic value of nuclear morphometry in canine anal sac gland adenocarcinomas. The results indicated that (1) MNA, MNP, MND and NR could be used as effective auxiliary tools for differential diagnosis between canine anal sac gland adenomas and adenocarcinomas, and (2) MNA, MNP and MND are reliable prognostic indicators for canine anal sac gland adenocarcinomas.

  10. Modeling the Rate-Dependent Durability of Reduced-Ag SAC Interconnects for Area Array Packages Under Torsion Loads

    NASA Astrophysics Data System (ADS)

    Srinivas, Vikram; Menon, Sandeep; Osterman, Michael; Pecht, Michael G.

    2013-08-01

    Solder durability models frequently focus on the applied strain range; however, the rate of applied loading, or strain rate, is also important. In this study, an approach to incorporate strain rate dependency into durability estimation for solder interconnects is examined. Failure data were collected for SAC105 solder ball grid arrays assembled with SAC305 solder that were subjected to displacement-controlled torsion loads. Strain-rate-dependent (Johnson-Cook model) and strain-rate-independent elastic-plastic properties were used to model the solders in finite-element simulation. Test data were then used to extract damage model constants for the reduced-Ag SAC solder. A generalized Coffin-Manson damage model was used to estimate the durability. The mechanical fatigue durability curve for reduced-silver SAC solder was generated and compared with durability curves for SAC305 and Sn-Pb from the literature.

  11. With Free Google Alert Services

    ERIC Educational Resources Information Center

    Gunn, Holly

    2005-01-01

    Alert services are a great way of keeping abreast of topics that interest you. Rather than searching the Web regularly to find new content about your areas of interest, an alert service keeps you informed by sending you notices when new material is added to the Web that matches your registered search criteria. Alert services are examples of push…

  12. Measurement of Lacrimal Sac Fossa Using Orbital Computed Tomography.

    PubMed

    Kang, Dongwan; Park, Jinhwan; Na, Jaehoon; Lee, Hwa; Baek, Sehyun

    2017-01-01

    To evaluate the clinical usefulness of measuring the lacrimal sac fossa length using orbital computed tomography in normal Koreans. The authors retrospectively evaluated 140 patients (70 males and 70 females) who underwent orbital computed tomography at Guro Hospital and who had no history of orbital disease or orbital trauma. Computed tomography scans of the right orbit, including the proportion of the lacrimal bone and maxillary bone that comprise the lacrimal sac fossa, were evaluated at 3 different axial planes (lower, middle, and upper levels). Additionally, the mid-point thickness and maximum thickness of the maxillary bone were measured. Finally, the authors also evaluated the relationship between nasal bone height and maxillary bone thickness in the lacrimal sac fossa. Maxillary bone thickness in the lacrimal sac fossa was thicker in males than in females at mid-point thickness and maximum thickness (P < 0.05). However, there was no significant difference in the size of the lacrimal sac fossa and the proportion of the maxillary bone between males and females.In comparisons between maxillary cross-sections, bone thickness was greater toward the upper level of the lacrimal sac fossa (P = 0.008), and the proportion of the maxillary bone was also greater (P = 0.006).Aging had a significant positive correlation with maxillary bone thickness at all 3 axial planes (P < 0.05), but there was no relationship between age and maxillary bone proportion. Nasal bone height and maxillary bone thickness were also not significantly related. In comprising the lacrimal sac fossa, the maxillary bone accounted for a bigger proportion than the lacrimal bone. Male maxillary bone thickness was greater than female thickness. The authors also observed that maxillary bone thickness increased toward the upper areas of the lacrimal sac fossa and with increasing subject age. Understanding the form and variation of a normal lacrimal sac fossa is helpful for preparing for a

  13. [Papilloma of the lacrimal sac].

    PubMed

    Burduk, Paweł K; Seredyka-Burduk, Małgorzata; Kaźmierczak, Wojciech; Dalke, Krzysztof; Marszałek, Andrzej

    2013-01-01

    The benign lesions of the lacrimal sac are very rare. The most typical epithelial tumor is squamous papilloma. This tumors often present with symptoms of dacryostenosis and dacriocystitis. Human papillomavirus (HPV) infection is known to be causative agent in the development of epithelial tumor. Lacrimal sac tumors could transform to malignant neoplasms, especially if they are developed of coexisting HPV infection. We present a patient with a squamous papilloma of the lacrimal sac and discussed the method of treatment. The patient was suffered from epiphora and recurrent dacriocystitis. An endoscopic surgery with dacriocystorhinostomy and local resection of the tumor could be an effective method of choice. The usage of a shaver for wide removal of the lacrimal sac wall is recommended to prevent local recurrence. The histopathology examination showed squamous papilloma. The patient is free of the disease over 8 months of follow up. Primary lacrimal sac papilloma require long term follow up for recurrence or malignant transformation. HPV infection could be associated with the development of lacrimal sac papillomas. Copyright © 2012 Polish Otorhinolaryngology - Head and Neck Surgery Society. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.

  14. Anal sac adenocarcinoma in a Siamese cat.

    PubMed

    Mellanby, R J; Foale, R; Friend, E; Woodger, N; Herrtage, M E; Dobson, J D

    2002-12-01

    A 12-year-old male neutered Siamese cat presented with a history of inappetance and lethargy and an enlarged left anal sac. The anal sac was surgically excised and histopathology confirmed the diagnosis of anal sac adenocarcinoma. Perianal tumours are rare in the cat and anal sac adenocarcinoma has not been previously reported. This is in contrast to the dog where anal sac adenocarcinoma is a well recognised albeit uncommon tumour.

  15. Squamous cell carcinoma of the anal sac in five dogs.

    PubMed

    Esplin, D G; Wilson, S R; Hullinger, G A

    2003-05-01

    Tumors of the perianal area of dogs are common and include multiple tumor types. Whereas perianal adenomas occur often, adenocarcinomas of the apocrine glands of the anal sac occur less frequently. A review of the literature revealed no reports of squamous cell carcinomas arising from the epithelial lining of the anal sac. Squamous cell carcinomas originating from the lining of the anal sac were diagnosed in five dogs. Microscopically, the tumors consisted of variably sized invasive nests and cords of epithelial cells displaying squamous differentiation. Four of the five dogs were euthanatized because of problems associated with local infiltration by the tumors. In the fifth dog, there was no evidence of tumor 7 months after surgical removal, but further follow up was not available.

  16. SAC-C Mission and the Morning Constellation

    NASA Astrophysics Data System (ADS)

    Colomb, F. R.; Alonso, C.; Hofmann, C.; Frulla, L.; Nollmann, I.; Milovich, J.; Kuba, J.; Ares, F.; Kalemkarian, M.

    2002-01-01

    SAC-C is an international Earth observing satellite mission conceived as a partnership between CONAE and NASA, but with additional support in instrumentation and satellite development from the Danish DSRI, the Italian ASI, the French CNES and the Brazilian INPE. A Delta II rocket successfully launched it on November 21st, 2000, from Vandenberg AFB, California, USA. SAC-C has been designed primarily to fulfill the requirements of countries with large extension of territory or scarcely populated like Argentina. Its design is a good compromise between resolution and swath width that makes SAC-C an appropriate tool for global and high dynamic phenomena studies. There are ten instruments on board of SAC-C that will perform different studies, the Multispectral Medium Resolution Scanner (MMRS), provided by CONAE, Argentina, will help in the studies about desertification processes evaluation and their evolution in time (i.e., Patagonia, Argentina), to identify and predict agriculture production, to monitor flood areas and to make studies in coastal and fluvial areas. The MMRS will be associated with a High Resolution Technological Camera (HRTC), also provided by CONAE that will permit improvement in the MMRS resolution in the areas where it will be required. A High Sensitivity Technological Camera (HSTC) is also included in the mission. SAC-C also carries instruments to monitor the condition and dynamics of the terrestrial and marine biosphere and environment (GPS OccuLtation and Passive reflection Experiment (GOLPE)) from NASA/JPL. The Magnetic Mapping Payload, (MMP) developed by the Danish Space Research Institute helps to better understand the Earth's magnetic field and related Sun -Earth interactions .Italian Star Tracker (IST) and Italian Navigation Experiment (INES) developed by the Italian Space Agency, constitute a technological payload that will permit testing a fully autonomous system for attitude and orbit determination. Influence of space radiation on advanced

  17. Endolymphatic Sac Decompression With Intra-Sac Dexamethasone Injection in Menière's Disease.

    PubMed

    Bojrab, Dennis I; LaRouere, Michael J; Bojrab, Dennis I; Babu, Seilesh C; Sargent, Eric W; Chan, Eleanor Y; Hong, Robert S

    2018-06-01

    Endolymphatic sac decompression surgery (ELSD) may be used to treat patients who have Menière's 's disease refractory to medical therapy. In this study, we investigated whether or not the injection of steroid into the endolymphatic sac at the time of ELSD provides additional benefit to patient outcomes. Randomized prospective single-blinded placebo-controlled study. Tertiary center. Patients with Menière's disease with poorly controlled vertigo despite medical therapy and serviceable hearing that were offered ELSD. Patients randomized into two groups, with control group (n = 17) undergone ELSD without steroid injection and experimental group undergone ELSD with steroid injection (n = 18) MAIN OUTCOME MEASURE(S):: Audiogram, dizziness handicap inventory, tinnitus handicap inventory, frequency of vertigo spells, functional level scale, and quality of life were obtained at multiple intervals from preoperatively to 24 months postoperatively. ELSD resulted in a statistically significant improvement in vertigo control whether or not steroid was injected into the endolymphatic sac at the time of surgery. However, no additional benefit was observed with the addition of intra-sac steroid injection. No statistical difference in pure-tone average, tinnitus handicap inventory, dizziness handicap inventory, or quality of life was observed between the steroid and nonsteroid surgical groups up to 24 months postoperatively. ELSD is an effective treatment for Menière's disease refractory to medical therapy; however, the addition of intra-sac steroid injection at the time of surgery does not seem to result in a further improvement in patient outcomes.

  18. COX-2 expression in canine anal sac adenocarcinomas and in non-neoplastic canine anal sacs.

    PubMed

    Knudsen, C S; Williams, A; Brearley, M J; Demetriou, J L

    2013-09-01

    Anal sac adenocarcinoma (ASAC) is a clinically significant canine neoplasm characterized by early lymphatic invasion. Up-regulation of cyclooxygenase isoform 2 (COX-2) has been confirmed in several animal and human neoplastic tissues. The aim of the current study was primarily to evaluate COX-2 expression in canine ASAC and compare it to COX-2 expression in non-neoplastic canine anal sac tissue using immunohistochemistry with scoring for percentage positivity and intensity. Twenty-five ASAC samples and 22 normal anal sacs were available for evaluation. All canine ASAC samples and the normal anal sac tissues stained positively for COX-2. However, while normal anal sac tissue showed strong staining of the ductal epithelial cells, ASAC samples showed staining of the neoplastic glandular epithelial cells, with varying percentage positivity and intensity between ASAC samples. COX-2 immunoreactivity of ASAC samples was of low intensity in 52% and high in 12% of the cases; the remaining samples were of intermediate intensity. Seventy-six per cent of the ASAC had over 50% of the neoplastic glandular cells staining positive. These results confirm that COX-2 is expressed in the neoplastic glandular epithelial cells in canine ASAC and suggest a potential role for COX-2 inhibitors in the management of ASAC. Furthermore, the results indicate that COX-2 is expressed in ductal epithelial cells of the normal anal sac. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Improving Conflict Alert Performance Using Moving Target Detector Data.

    DTIC Science & Technology

    1982-06-01

    2 L136 IIIII I lIlS 1 1 10 11120 125 11111I ~1.6 MICROCOPY RESOLUTION TEST CHART NATIONAL BUREAU Of SIANDARDg 19bi A DOT/FAA/RD-82/47 DOT/FAA/CT-81...Differences for Stochastic Case 23 7 Illustration of Scenarios for Warning Time Tests 30 8 Illustration of Scenarios Used for Nuisance Alert 35 Area...Nuisance Alert Area Analysis of Scenario 3 with a Target 64 Velocity of 480 Knots and SPMB= SPPB =2.8 nmi 12 Nuisance Alert Area Analysis of Scenario 3

  20. Advanced alerting features: displaying new relevant data and retracting alerts.

    PubMed Central

    Kuperman, G. J.; Hiltz, F. L.; Teich, J. M.

    1997-01-01

    We added two advanced features to our automated alerting system. The first feature identifies and displays, at the time an alert is reviewed, relevant data filed between the login time of a specimen leading to an alerting result and the time the alert is reviewed. Relevant data is defined as data of the same kind as generated the alert. The other feature retracts alerts when the alerting value is edited and no longer satisfies the alerting criteria. We evaluated the two features for a 14-week period (new relevant data) and a 6-week period (retraction). Of a total of 1104 alerts in the 14-week evaluation, 286 (25.9%) had new relevant data displayed at alert review time. Of the 286, 75.2% were due to additions of comments to the original piece of alerting data; 24.1% were due to new or pending laboratory results of the same type that generated the alert. Two alerts (out of 490) were retracted in a 6 week period. We conclude that in our system, new clinically relevant data is often added between the time of specimen login and the time that an alerting result from that specimen is reviewed. Retractions occur rarely but are important to detect and communicate. PMID:9357625

  1. Efficacy of Several Pesticide Products on Brown Widow Spider (Araneae: Theridiidae) Egg Sacs and Their Penetration Through the Egg Sac Silk.

    PubMed

    Vetter, Richard S; Tarango, Jacob; Campbell, Kathleen A; Tham, Christine; Hayashi, Cheryl Y; Choe, Dong-Hwan

    2016-02-01

    Information on pesticide effects on spiders is less common than for insects; similar information for spider egg sacs is scarcer in the open literature. Spider egg sacs are typically covered with a protective silk layer. When pesticides are directly applied to egg sacs, the silk might prevent active ingredients from reaching the eggs, blocking their insecticidal effect. We investigated the impact of six water-based pesticide sprays and four oil-based aerosol products against egg sacs of brown widow spiders, Latrodectus geometricus C. L. Koch. All water-based spray products except one failed to provide significant mortality to egg sacs, resulting in successful spiderling emergence from treated egg sacs at a similar rate to untreated egg sacs. In contrast to water-based sprays, oil-based aerosols provided almost complete control, with 94-100% prevention of spiderling emergence. Penetration studies using colored pesticide products indicated that oil-based aerosols were significantly more effective in penetrating egg sac silk than were the water-based sprays, delivering the active ingredients on most (>99%) of the eggs inside the sac. The ability of pesticides to penetrate spider egg sac silk and deliver lethal doses of active ingredients to the eggs is discussed in relation to the chemical nature of egg sac silk proteins. Our study suggests that pest management procedures primarily relying on perimeter application of water-based sprays might not provide satisfactory control of brown widow spider eggs. Determination of the most effective active ingredients and carrier characteristics warrant further research to provide more effective control options for spider egg sacs. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy

    DTIC Science & Technology

    2012-03-01

    for the consumer at the mo- ment but will soon become a commoditized, basic requirement. For example, as the baby boomers grow older, mobile services...Commercial Mobile Alert Service (CMAS) Alerting Pipeline Taxonomy The WEA Project Team March 2012 SPECIAL REPORT CMU/SEI-2012-TR-019 CERT...report presents a taxonomy developed for the Commercial Mobile Alert Service (CMAS). The CMAS Alerting Pipeline Taxonomy is a hierarchical classification

  3. Aquarius SAC-D Launch

    NASA Image and Video Library

    2011-06-09

    A Delta II rocket launches with the Aquarius/SAC-D spacecraft payload from Space Launch Complex 2 at Vandenberg Air Force Base, Calif. on Friday, June 10, 2011. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  4. Aquarius SAC-D Launch

    NASA Image and Video Library

    2011-06-10

    A Delta II rocket launches with the Aquarius/SAC-D spacecraft payload from Space Launch Complex 2 at Vandenberg Air Force Base, Calif. on Friday, June 10, 2011. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, set to launch June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  5. Aquarius SAC-D Launch

    NASA Image and Video Library

    2011-06-08

    The Delta II rocket with it's Aquarius/SAC-D spacecraft payload is seen shortly after the service structure is rolled back on Thursday, June 9, 2011, at Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, set to launch June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  6. Aquarius SAC-D Launch

    NASA Image and Video Library

    2011-06-08

    The Delta II rocket with it's Aquarius/SAC-D spacecraft payload is seen as the service structure is rolled back on Thursday, June 9, 2011, at Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, set to launch June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  7. Thermodynamic Alerter for Microbursts (TAMP)

    NASA Technical Reports Server (NTRS)

    Eccles, Peter J.

    1991-01-01

    The following subject areas are covered: microburst detection, location and measurement; thermal alerter for microbursts prototypes (TAMP); sensor-transmitters (Senstrans) design; TAMP installation; and DAPAD software.

  8. SAC-A satellite

    NASA Image and Video Library

    1998-12-14

    S88-E-5161 (12-14-98) --- Before beginning their pre-sleep period on their next to last day in space, the STS-88 astronauts deployed a small 590-pound satellite called SAC-A for the Argentinean National Committee of Space Activities. Equipped with five technology experiments, including one to track the movement of whales off the coast of Argentina, SAC-A was ejected from a canister in Endeavour's cargo bay at 10:31 p.m. Central time as the shuttle few over the northern Indian Ocean. The satellite is expected to remain in orbit from five to nine months sending back data to Argentine researchers back on Earth. The photo was taken with an electronic still camera (ESC) at 04:35:48 GMT, Dec. 14.

  9. Macrofauna community inside and outside of the Darwin Mounds SAC, NE Atlantic

    NASA Astrophysics Data System (ADS)

    Serpetti, N.; Gontikaki, E.; Narayanaswamy, B. E.; Witte, U.

    2012-11-01

    Over the past two decades, growing concerns have been raised regarding the effects of towed fishing gears, such as trawls and dredges, on deep-sea biodiversity and ecosystem functioning. Trawling disturbs the benthic communities both physically and biologically, and can eliminate the most vulnerable organisms and modify habitat structure; chronically disturbed communities are often dominated by opportunistic species. The European Union is under obligation to designate a network of offshore Special Areas of Conservation (SACs) and Marine Protected Areas (MPAs) by the end of 2012 based on the perceived expectation that these networks will help protect marine biodiversity and that within these areas, faunal abundance and diversity will be higher than the surrounding fished areas. The Darwin Mounds, only discovered in 1998, are located in the Rockall Trough, NE Atlantic at a depth of ~ 1000 m. Deep-water trawling regularly took place in the region of the Darwin Mounds; however in 2004 the mounds were designated as the first offshore SAC in UK and the area is now closed to bottom trawling. As part of the HERMIONE programme the influence of human impact on the Oceans was one of the key themes and in June 2011, an investigation of the macrofaunal community structure at comparable sites both inside and outside of the Darwin Mound SAC was undertaken. Macrofaunal communities were found to differ significantly, with the difference mostly driven by changes in the abundance of polychaetes, crustaceans and nematodes whilst no significant differences were seen for the other phyla. Whereas overall macrofaunal abundance was higher outside the SAC compared to within, this pattern varies considerably between phyla. Diversity indices showed no significant differences between protected and unprotected sites. This could indicate that a few years of preservation are not enough time to determine a recovery by the macrofaunal community of cold-water ecosystems and that a continued

  10. Temporally separated bilateral anal sac gland carcinomas in four dogs.

    PubMed

    Bowlt, K L; Friend, E J; Delisser, P; Murphy, S; Polton, G

    2013-08-01

    Anal sac gland carcinoma arising from the apocrine secretory epithelium in the anal sac wall, is locally invasive and highly metastatic. The majority of anal sac gland carcinomas are unilateral on presentation, but bilateral tumours have been identified. This case series presents the outcome of four unique cases of unilateral anal sac gland carcinoma which subsequently developed contralateral anal sac gland carcinoma 50 to 390 days after removal of the initial tumour. Median survival was 1035 days after initial diagnosis and 807 days after diagnosis of the second anal sac gland carcinoma. © 2013 British Small Animal Veterinary Association.

  11. Intranasal anatomy of the nasolacrimal sac in endoscopic dacryocystorhinostomy.

    PubMed

    Wormald, P J; Kew, J; Van Hasselt, A

    2000-09-01

    Intranasal surface anatomy is fundamental to the technique of endoscopic dacryocystorhinostomy. In the current literature the lacrimal sac is described as being situated anterior to the anterior end of the middle turbinate with between 0% and 20% of the sac above the insertion of the middle turbinate on the lateral nasal wall (the axilla of the middle turbinate). The aim of this study was to use CT dacryocystograms (DCGs) and CT scans to establish the relationship of the lacrimal sac to the lateral nasal wall. Forty-seven individual lacrimal sacs were measured in relation to the common canaliculus, and 76 were measured in relation to the insertion of the middle turbinate. Measurements taken from the long axis of the sac showed the mean height of the sac above the middle turbinate insertion was 8.8 mm (SD = 0.2, 95% CI = 1.3) and below it was 4.1 mm (SD = 2.3, 95% CI = 1.1). The average measurement of the sac above the com-mon canaliculus on CT DCGs was 5.3 mm (SD = 1.7, 95% CI = 0.56), whereas the average measurement below the common canaliculus was 7.7 mm (SD = 2, 95% CI = 1.3) (n = 47 CT DCGs). The findings in this study show that a major portion of the sac is locat-ed above the insertion of the anterior end of the middle turbinate and, in addition, that a significant part of the sac lies above the entry point of the common canaliculus. Knowledge of these findings can ensure that the sac is adequately exposed during dacryocystorhinostomy by removal of sufficient bone and mucosa above the anterior insertion of the middle turbinate.

  12. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts

    PubMed Central

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras

    2016-01-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time—the time elapsed from when an interruptive alert is generated to when it is dismissed—could be calculated by using historical alert data from log files. Drug–drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1–4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < .001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < .001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. PMID:26499101

  13. Transvaginal ultrasound in threatened abortions with empty gestational sacs.

    PubMed

    Tongsong, T; Wanapirak, C; Srisomboon, J; Sirichotiyakul, S; Polsrisuthikul, T; Pongsatha, S

    1994-09-01

    To determine whether transvaginal ultrasound criteria alone can distinguish viable from non-viable gestational sacs at a single examination. A prospective descriptive study was undertaken and analysis performed on 211 pregnancies complicated by threatened abortion and empty gestation sacs diagnosed by transvaginal ultrasound. The main outcome measure was the final diagnosis of viable or non-viable gestation on subsequent transvaginal sonography. The study shows that a single transvaginal ultrasound examination is useful in differentiating viable from non-viable gestation sacs. The mean sac diameter (MSD) was found to be the most useful criterion for determining non-viability. An MSD of > or = 17 mm that lacked an embryo and an MSD of > or = 13 mm without visible yolk sac were reliable predictors of non-viable gestation sacs at a single examination with 100% specificity and 100% positive predictive value. An MSD > or = 13 mm without visible yolk sac was the most sensitive criterion. Using MSD criteria, 73% of non-viable gestations could be reliably identified without any false-positive diagnoses. Deformed shape, low position and thin decidual reaction are strong indicators of non-viable gestations but are not 100% accurate. There is still a significant proportion of empty sacs, where no accurate distinction between viable and non-viable can be made according to one criterion at a single examination and in these cases serial examinations should be carried out before any active management is advocated. In most cases, transvaginal sonographic criteria alone can distinguish viable from non-viable empty gestational sacs at a single examination.

  14. SAC Headquarters Underground Command Center Cutaway Axonometric Offutt ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SAC Headquarters Underground Command Center - Cutaway Axonometric - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  15. Alert dwell time: introduction of a measure to evaluate interruptive clinical decision support alerts.

    PubMed

    McDaniel, Robert B; Burlison, Jonathan D; Baker, Donald K; Hasan, Murad; Robertson, Jennifer; Hartford, Christine; Howard, Scott C; Sablauer, Andras; Hoffman, James M

    2016-04-01

    Metrics for evaluating interruptive prescribing alerts have many limitations. Additional methods are needed to identify opportunities to improve alerting systems and prevent alert fatigue. In this study, the authors determined whether alert dwell time-the time elapsed from when an interruptive alert is generated to when it is dismissed-could be calculated by using historical alert data from log files. Drug-drug interaction (DDI) alerts from 3 years of electronic health record data were queried. Alert dwell time was calculated for 25,965 alerts, including 777 unique DDIs. The median alert dwell time was 8 s (range, 1-4913 s). Resident physicians had longer median alert dwell times than other prescribers (P < 001). The 10 most frequent DDI alerts (n = 8759 alerts) had shorter median dwell times than alerts that only occurred once (P < 001). This metric can be used in future research to evaluate the effectiveness and efficiency of interruptive prescribing alerts. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Ultrasound parameters of normal lacrimal sac and chronic dacryocystitis.

    PubMed

    Machado, Marco Antonio de Campos; Silva, João Amaro Ferrari; Garcia, Eduardo Alonso; Allemann, Norma

    2017-06-01

    To compared the ultrasound findings of the lacrimal sac between subjects with normal lacrimal systems those with chronic dacryocystitis. A retrospective study of 10 subjects with a normal lacrimal system (Group 1) and 10 with chronic dacryocystitis (Group 2) diagnosed according to B-mode ultrasound with a 10-MHz transducer and the direct-contact technique (AVISO, Quantel Medical) for lacrimal sac assessment. We analyzed the dimensions, features, and content of the sacs. Characteristics of the population: female: 6, Group 1; 8, Group 2; mean age 48.4 years (SD=19.9; range, 22-80 years), Group 1; 50.5 years (SD=15.5; range, 25-75 years), Group 2. The dimensions of the lacrimal sac were as follows: anteroposterior 1.86 and 10.99 mm in Groups 1 and 2, respectively, p<0.0001; vertical 9.79 and 14.13 mm in Groups 1 and 2, respectively, p=0.049. Qualitative evaluation of the lacrimal sac contents showed hypoechogenic content in Group 1 (10, 100%) and hyperechogenic punctiform content in Group 2 (10, 100%) with partial filling in seven cases (70%). Ultrasonography can differentiate normal lacrimal sacs from sacs compromised by chronic dacryocystitis, thus being useful as an adjunct to clinical examination and surgical planning.

  17. CHEMICAL SAFETY ALERTS-

    EPA Science Inventory

    Chemical Safety Alerts are short publications which explain specific hazards that have become evident through chemical accident investigation efforts. EPA has produced over a dozen Alerts to date. This year's Alert: Managing Chemical Reactivity Hazards

  18. INTERIOR OF BUILDING, SHOWING PIPELINES. view TO NORTH Plattsburgh ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR OF BUILDING, SHOWING PIPELINES. view TO NORTH - Plattsburgh Air Force Base, Industrial Wastewater Treatment & Disposal Facility, Off LeMay Road, outside SAC Alert Area, Plattsburgh, Clinton County, NY

  19. Wireless Emergency Alerts (WEA) Cybersecurity Risk Management Strategy for Alert Originators

    DTIC Science & Technology

    2014-03-01

    formerly known as the Commercial Mobile Alert Service ( CMAS ) RDT&E program, is a collaborative partnership that includes the cellular industry, the...Examples illustrate a STRIDE analysis of the generic mission 1 The CMAS Alerting Pipeline Taxonomy describes in detail a hierarchical classification...SEI-2013-SR-018 | 1 1 Introduction The Wireless Emergency Alerts (WEA) service, formerly known as the Commercial Mobile Alert Service ( CMAS ), is a

  20. Technologic Distractions (Part 1): Summary of Approaches to Manage Alert Quantity With Intent to Reduce Alert Fatigue and Suggestions for Alert Fatigue Metrics.

    PubMed

    Kane-Gill, Sandra L; O'Connor, Michael F; Rothschild, Jeffrey M; Selby, Nicholas M; McLean, Barbara; Bonafide, Christopher P; Cvach, Maria M; Hu, Xiao; Konkani, Avinash; Pelter, Michele M; Winters, Bradford D

    2017-09-01

    To provide ICU clinicians with evidence-based guidance on tested interventions that reduce or prevent alert fatigue within clinical decision support systems. Systematic review of PubMed, Embase, SCOPUS, and CINAHL for relevant literature from 1966 to February 2017. Focus on critically ill patients and included evaluations in other patient care settings, as well. Identified interventions designed to reduce or prevent alert fatigue within clinical decision support systems. Study selection was based on one primary key question to identify effective interventions that attempted to reduce alert fatigue and three secondary key questions that covered the negative effects of alert fatigue, potential unintended consequences of efforts to reduce alert fatigue, and ideal alert quantity. Data were abstracted by two reviewers independently using a standardized abstraction tool. Surveys, meeting abstracts, "gray" literature, studies not available in English, and studies with non-original data were excluded. For the primary key question, articles were excluded if they did not provide a comparator as key question 1 was designed as a problem, intervention, comparison, and outcome question. We anticipated that reduction in alert fatigue, including the concept of desensitization may not be directly measured and thus considered interventions that reduced alert quantity as a surrogate marker for alert fatigue. Twenty-six articles met the inclusion criteria. Approaches for managing alert fatigue in the ICU are provided as a result of reviewing tested interventions that reduced alert quantity with the anticipated effect of reducing fatigue. Suggested alert management strategies include prioritizing alerts, developing sophisticated alerts, customizing commercially available alerts, and including end user opinion in alert selection. Alert fatigue itself is studied less frequently, as an outcome, and there is a need for more precise evaluation. Standardized metrics for alert fatigue is

  1. Triggering Interventions for Influenza: The ALERT Algorithm

    PubMed Central

    Reich, Nicholas G.; Cummings, Derek A. T.; Lauer, Stephen A.; Zorn, Martha; Robinson, Christine; Nyquist, Ann-Christine; Price, Connie S.; Simberkoff, Michael; Radonovich, Lewis J.; Perl, Trish M.

    2015-01-01

    Background. Early, accurate predictions of the onset of influenza season enable targeted implementation of control efforts. Our objective was to develop a tool to assist public health practitioners, researchers, and clinicians in defining the community-level onset of seasonal influenza epidemics. Methods. Using recent surveillance data on virologically confirmed infections of influenza, we developed the Above Local Elevated Respiratory Illness Threshold (ALERT) algorithm, a method to identify the period of highest seasonal influenza activity. We used data from 2 large hospitals that serve Baltimore, Maryland and Denver, Colorado, and the surrounding geographic areas. The data used by ALERT are routinely collected surveillance data: weekly case counts of laboratory-confirmed influenza A virus. The main outcome is the percentage of prospective seasonal influenza cases identified by the ALERT algorithm. Results. When ALERT thresholds designed to capture 90% of all cases were applied prospectively to the 2011–2012 and 2012–2013 influenza seasons in both hospitals, 71%–91% of all reported cases fell within the ALERT period. Conclusions. The ALERT algorithm provides a simple, robust, and accurate metric for determining the onset of elevated influenza activity at the community level. This new algorithm provides valuable information that can impact infection prevention recommendations, public health practice, and healthcare delivery. PMID:25414260

  2. On the robustness of SAC silencing in closed mitosis

    NASA Astrophysics Data System (ADS)

    Ruth, Donovan; Liu, Jian

    Mitosis equally partitions sister chromatids to two daughter cells. This is achieved by properly attaching these chromatids via their kinetochores to microtubules that emanate from the spindle poles. Once the last kinetochore is properly attached, the spindle microtubules pull the sister chromatids apart. Due to the dynamic nature of microtubules, however, kinetochore-microtubule attachment often goes wrong. When this erroneous attachment occurs, it locally activates an ensemble of proteins, called the spindle assembly checkpoint proteins (SAC), which halts the mitotic progression until all the kinetochores are properly attached by spindle microtubules. The timing of SAC silencing thus determines the fidelity of chromosome segregation. We previously established a spatiotemporal model that addresses the robustness of SAC silencing in open mitosis for the first time. Here, we focus on closed mitosis by examining yeast mitosis as a model system. Though much experimental work has been done to study the SAC in cells undergoing closed mitosis, the processes responsible are not well understood. We leverage and extend our previous model to study SAC silencing mechanism in closed mitosis. We show that a robust signal of the SAC protein accumulation at the spindle pole body can be achieved. This signal is a nonlinear increasing function of number of kinetochore-microtubule attachments, and can thus serve as a robust trigger to time the SAC silencing. Together, our mechanism provides a unified framework across species that ensures robust SAC silencing and fidelity of chromosome segregation in mitosis. Intramural research program in NHLBI at NIH.

  3. Revealing the functional neuroanatomy of intrinsic alertness using fMRI: methodological peculiarities.

    PubMed

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander T; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that--as a methodological artifact--left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing the

  4. Revealing the Functional Neuroanatomy of Intrinsic Alertness Using fMRI: Methodological Peculiarities

    PubMed Central

    Clemens, Benjamin; Zvyagintsev, Mikhail; Sack, Alexander; Heinecke, Armin; Willmes, Klaus; Sturm, Walter

    2011-01-01

    Clinical observations and neuroimaging data revealed a right-hemisphere fronto-parietal-thalamic-brainstem network for intrinsic alertness, and additional left fronto-parietal activity during phasic alertness. The primary objective of this fMRI study was to map the functional neuroanatomy of intrinsic alertness as precisely as possible in healthy participants, using a novel assessment paradigm already employed in clinical settings. Both the paradigm and the experimental design were optimized to specifically assess intrinsic alertness, while at the same time controlling for sensory-motor processing. The present results suggest that the processing of intrinsic alertness is accompanied by increased activity within the brainstem, thalamus, anterior cingulate gyrus, right insula, and right parietal cortex. Additionally, we found increased activation in the left hemisphere around the middle frontal gyrus (BA 9), the insula, the supplementary motor area, and the cerebellum. Our results further suggest that rather minute aspects of the experimental design may induce aspects of phasic alertness, which in turn might lead to additional brain activation in left-frontal areas not normally involved in intrinsic alertness. Accordingly, left BA 9 activation may be related to co-activation of the phasic alertness network due to the switch between rest and task conditions functioning as an external warning cue triggering the phasic alertness network. Furthermore, activation of the intrinsic alertness network during fixation blocks due to enhanced expectancy shortly before the switch to the task block might, when subtracted from the task block, lead to diminished activation in the typical right hemisphere intrinsic alertness network. Thus, we cautiously suggest that – as a methodological artifact – left frontal activations might show up due to phasic alertness involvement and intrinsic alertness activations might be weakened due to contrasting with fixation blocks, when assessing

  5. Real-time alerts and reminders using information systems.

    PubMed

    Wanderer, Jonathan P; Sandberg, Warren S; Ehrenfeld, Jesse M

    2011-09-01

    Adoption of information systems throughout the hospital environment has enabled the development of real-time physiologic alerts and clinician reminder systems. These clinical tools can be made available through the deployment of anesthesia information management systems (AIMS). Creating usable alert systems requires understanding of technical considerations. Various successful implementations are reviewed, encompassing cost reduction, improved revenue capture, timely antibiotic administration, and postoperative nausea and vomiting prophylaxis. Challenges to the widespread use of real-time alerts and reminders include AIMS adoption rates and the difficulty in choosing appropriate areas and approaches for information systems support. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Diagnostic imaging features of normal anal sacs in dogs and cats.

    PubMed

    Jung, Yechan; Jeong, Eunseok; Park, Sangjun; Jeong, Jimo; Choi, Ul Soo; Kim, Min-Su; Kim, Namsoo; Lee, Kichang

    2016-09-30

    This study was conducted to provide normal reference features for canine and feline anal sacs using ultrasound, low-field magnetic resonance imaging (MRI) and radiograph contrast as diagnostic imaging tools. A total of ten clinically normal beagle dogs and eight clinically normally cats were included. General radiography with contrast, ultrasonography and low-field MRI scans were performed. The visualization of anal sacs, which are located at distinct sites in dogs and cats, is possible with a contrast study on radiography. Most surfaces of the anal sacs tissue, occasionally appearing as a hyperechoic thin line, were surrounded by the hypoechoic external sphincter muscle on ultrasonography. The normal anal sac contents of dogs and cats had variable echogenicity. Signals of anal sac contents on low-field MRI varied in cats and dogs, and contrast medium using T1-weighted images enhanced the anal sac walls more obviously than that on ultrasonography. In conclusion, this study provides the normal features of anal sacs from dogs and cats on diagnostic imaging. Further studies including anal sac evaluation are expected to investigate disease conditions.

  7. Diagnostic imaging features of normal anal sacs in dogs and cats

    PubMed Central

    Jung, Yechan; Jeong, Eunseok; Park, Sangjun; Jeong, Jimo; Choi, Ul Soo; Kim, Min-Su; Kim, Namsoo

    2016-01-01

    This study was conducted to provide normal reference features for canine and feline anal sacs using ultrasound, low-field magnetic resonance imaging (MRI) and radiograph contrast as diagnostic imaging tools. A total of ten clinically normal beagle dogs and eight clinically normally cats were included. General radiography with contrast, ultrasonography and low-field MRI scans were performed. The visualization of anal sacs, which are located at distinct sites in dogs and cats, is possible with a contrast study on radiography. Most surfaces of the anal sacs tissue, occasionally appearing as a hyperechoic thin line, were surrounded by the hypoechoic external sphincter muscle on ultrasonography. The normal anal sac contents of dogs and cats had variable echogenicity. Signals of anal sac contents on low-field MRI varied in cats and dogs, and contrast medium using T1-weighted images enhanced the anal sac walls more obviously than that on ultrasonography. In conclusion, this study provides the normal features of anal sacs from dogs and cats on diagnostic imaging. Further studies including anal sac evaluation are expected to investigate disease conditions. PMID:26645338

  8. SAC: Sheffield Advanced Code

    NASA Astrophysics Data System (ADS)

    Griffiths, Mike; Fedun, Viktor; Mumford, Stuart; Gent, Frederick

    2013-06-01

    The Sheffield Advanced Code (SAC) is a fully non-linear MHD code designed for simulations of linear and non-linear wave propagation in gravitationally strongly stratified magnetized plasma. It was developed primarily for the forward modelling of helioseismological processes and for the coupling processes in the solar interior, photosphere, and corona; it is built on the well-known VAC platform that allows robust simulation of the macroscopic processes in gravitationally stratified (non-)magnetized plasmas. The code has no limitations of simulation length in time imposed by complications originating from the upper boundary, nor does it require implementation of special procedures to treat the upper boundaries. SAC inherited its modular structure from VAC, thereby allowing modification to easily add new physics.

  9. OVERALL VIEW OF CONTROL BUILDING AND SECURITY GATE. VIEW TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    OVERALL VIEW OF CONTROL BUILDING AND SECURITY GATE. VIEW TO NORTH. - Plattsburgh Air Force Base, Security Police Entry Control Building, Off Perimeter Road in SAC Alert Area, Plattsburgh, Clinton County, NY

  10. Specific lignin accumulation in granulated juice sacs of Citrus maxima.

    PubMed

    Wu, Jia-Ling; Pan, Teng-Fei; Guo, Zhi-Xiong; Pan, Dong-Ming

    2014-12-17

    Juice sac granulation occurring in pummelo fruits [Citrus maxima (Burm.) Merr.] is an undesirable trait, and the underlying mechanism remains unresolved. Previous studies have shown that lignin metabolism is closely associated with the process of juice sac granulation. Here, a method suitable for lignin isolation from pummelo tissues is established. Acetylated lignins from different pummelo tissues and cultivars were analyzed by HSQC NMR. The results showed that lignins in granulated juice sacs were characterized by an extremely high abundance of guaiacyl units (91.13-96.82%), in contrast to lignins from other tissues, including leaves, stems, and segment membranes. The abnormally accumulated lignins in granulated juice sacs were specific and mainly polymerized from coniferyl alcohol. No significant difference was found in lignin types among various cultivars. These findings indicated that the mechanism of juice sac granulation might be similar among various cultivars, although very different degrees of juice sac granulation can be observed.

  11. Flood warnings in coastal areas: how do social and behavioural patterns influence alert services?

    NASA Astrophysics Data System (ADS)

    Pescaroli, G.; Magni, M.

    2015-01-01

    Many studies discuss the economic and technical aspects of flood warnings. Less attention has been given to the social and psychological patterns that affect alert services. In particular, the literature focuses on warnings activated in river basins or marine environments without providing clear evidence of relevance to Mediterranean coastal areas, even though these are subjected to growing flood risk related to climate change. This paper is a first attempt to bridge this gap. Our research develops an in- depth analysis of the village of Cesenatico on the Adriatic Sea coast. Here the municipality adopted two complementary warning systems: a siren and an alert via Short Message Service (SMS). The analysis focuses on a survey conducted in 2011 and 2012 with 228 participants. The relationships between social and behavioural variables and warning services are investigated, and so are flood preparedness and information dissemination. Qualitative evidence from informal interviews is used to support the understanding of key responses. The conclusions show how different social and behavioural patterns can influence the effectiveness and use of warning systems, regardless of the technology adopted and the structural mitigation measures implemented. Education, training and accountability are seen to be critical elements for improvement. Finally, the statistical output is used to suggest new questions and new directions for research.

  12. SOUTHEAST (FRONT) AND NORTHEAST (SIDE) ELEVATIONS OF BUILDING. VIEW TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SOUTHEAST (FRONT) AND NORTHEAST (SIDE) ELEVATIONS OF BUILDING. VIEW TO WEST - Plattsburgh Air Force Base, Industrial Wastewater Treatment & Disposal Facility, Off LeMay Road, outside SAC Alert Area, Plattsburgh, Clinton County, NY

  13. NORTHEAST (SIDE) AND NORTHWEST (REAR) ELEVATIONS OF BUILDING. VIEW TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTHEAST (SIDE) AND NORTHWEST (REAR) ELEVATIONS OF BUILDING. VIEW TO SOUTH - Plattsburgh Air Force Base, Industrial Wastewater Treatment & Disposal Facility, Off LeMay Road, outside SAC Alert Area, Plattsburgh, Clinton County, NY

  14. SOUTHEAST (FRONT) AND SOUTHWEST (SIDE) ELEVATIONS OF BUILDING. view TO ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SOUTHEAST (FRONT) AND SOUTHWEST (SIDE) ELEVATIONS OF BUILDING. view TO NORTH - Plattsburgh Air Force Base, Industrial Wastewater Treatment & Disposal Facility, Off LeMay Road, outside SAC Alert Area, Plattsburgh, Clinton County, NY

  15. XPS of oxygen atoms on Ag(111) and Ag(110) surfaces: accurate study with SAC/SAC-CI combined with dipped adcluster model.

    PubMed

    Ishikawa, Atsushi; Nakatsuji, Hiroshi

    2013-08-05

    O1s core-electron binding energies (CEBE) of the atomic oxygens on different Ag surfaces were investigated by the symmetry adapted cluster-configuration interaction (SAC-CI) method combined with the dipped adcluster model, in which the electron exchange between bulk metal and adsorbate is taken into account properly. Electrophilic and nucleophilic oxygens (O(elec) and O(nuc)) that might be important for olefin epoxidation in a low-oxygen coverage condition were focused here. We consider the O1s CEBE as a key property to distinguish the surface oxygen states, and series of calculation was carried out by the Hartree-Fock, Density functional theory, and SAC/SAC-CI methods. The experimental information and our SAC/SAC-CI results indicate that O(elec) is the atomic oxygen adsorbed on the fcc site of Ag(111) and that O(nuc) is the one on the reconstructed added-row site of Ag(110) and that one- and two-electron transfers occur, respectively, to the O(elec) and O(nuc) adclusters from the silver surface. Copyright © 2013 Wiley Periodicals, Inc.

  16. Jetliner Alert Systems

    NASA Technical Reports Server (NTRS)

    1983-01-01

    NASA research and design has significantly improved crew alert systems. The Engine Indication and Crew Alerting System (EICAS), developed by Psycho-Linguistic Research Associates, is technologically advanced and able to order alerts by priority. Ames has also developed computer controlled voice synthesizers for readouts during difficult landing approaches. This is available to airplane manufacturers.

  17. 70. SAC command post construction, building 500, undated Offutt ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    70. SAC command post construction, building 500, undated - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  18. 59. SAC Plaque, front lawn, building 500, looking east ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    59. SAC Plaque, front lawn, building 500, looking east - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  19. INITIATE: An Intelligent Adaptive Alert Environment.

    PubMed

    Jafarpour, Borna; Abidi, Samina Raza; Ahmad, Ahmad Marwan; Abidi, Syed Sibte Raza

    2015-01-01

    Exposure to a large volume of alerts generated by medical Alert Generating Systems (AGS) such as drug-drug interaction softwares or clinical decision support systems over-whelms users and causes alert fatigue in them. Some of alert fatigue effects are ignoring crucial alerts and longer response times. A common approach to avoid alert fatigue is to devise mechanisms in AGS to stop them from generating alerts that are deemed irrelevant. In this paper, we present a novel framework called INITIATE: an INtellIgent adapTIve AlerT Environment to avoid alert fatigue by managing alerts generated by one or more AGS. We have identified and categories the lifecycle of different alerts and have developed alert management logic as per the alerts' lifecycle. Our framework incorporates an ontology that represents the alert management strategy and an alert management engine that executes this strategy. Our alert management framework offers the following features: (1) Adaptability based on users' feedback; (2) Personalization and aggregation of messages; and (3) Connection to Electronic Medical Records by implementing a HL7 Clinical Document Architecture parser.

  20. Alert generation and cockpit presentation for an integrated microburst alerting system

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Hansman, R. John, Jr.

    1991-01-01

    Alert generation and cockpit presentation issues for low level wind shear (microburst) alerts are investigated. Alert generation issues center on the development of a hazard criterion which allows integration of both ground based and airborne wind shear detection systems to form an accurate picture of the aviation hazard posed by a particular wind shear situation. A methodology for the testing of a hazard criteria through flight simulation has been developed, and has been used to examine the effectiveness and feasibility of several possible criteria. Also, an experiment to evaluate candidate graphical cockpit displays for microburst alerts using a piloted simulator has been designed.

  1. Detecting alerts, notifying the physician, and offering action items: a comprehensive alerting system.

    PubMed Central

    Kuperman, G. J.; Teich, J. M.; Bates, D. W.; Hiltz, F. L.; Hurley, J. M.; Lee, R. Y.; Paterno, M. D.

    1996-01-01

    We developed and evaluated a system to automatically identify serious clinical conditions in inpatients. The system notifies the patient's covering physician via his pager that an alert is present and offers potential therapies for the patient's condition (action items) at the time he views the alert information. Over a 6 month period, physicians responded to 1214 (70.2%) of 1730 alerts for which they were paged; they responded to 1002 (82.5% of the 1214) in less than 15 minutes. They said they would take action in 71.5% of the alerts, and they placed an order directly from the alert display screen in 39.4%. Further study is needed to determine if this alerting system improves processes or outcomes of care. PMID:8947756

  2. Aquarius and the Aquarius/SAC-D Mission

    NASA Technical Reports Server (NTRS)

    LeVine, D. M.; Lagerloef, G. S. E.; Torrusio, S.

    2010-01-01

    Aquarius is a combination L-band radiometer and scatterometer designed to map the salinity field at the ocean surface from space. It will be flown on the Aquarius/SAC-D mission, a partnership between the USA space agency (NASA) and Argentine space agency (CONAE). The mission is composed of two parts: (a) The Aquarius instrument being developed as part of NASA.s Earth System Science Pathfinder (ESSP) program; and (b) SAC-D the fourth spacecraft service platform in the CONAE Satellite de Aplicaciones Cientificas (SAC) program. The primary focus of the mission is to monitor the seasonal and interannual variations of the salinity field in the open ocean. The mission also meets the needs of the Argentine space program for monitoring the environment and for hazard detection and includes several instruments related to these goals.

  3. 2. VIEW OF SOUTH END OF STRUCTURE NO. 540 (ALERT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. VIEW OF SOUTH END OF STRUCTURE NO. 540 (ALERT AIRCRAFT PARKING APRON) LOOKING SOUTHEAST FROM THE MASTER SURVEILLANCE AND CONTROL TOWER (BUILDING 8990) WITH CREW READINESS BUILDING (BUILDING 8970) IN BACKGROUND. - Loring Air Force Base, Alert Area, Southeastern portion of base, east of southern end of runway, Limestone, Aroostook County, ME

  4. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Conrado Varotto, CONAE Executive and Technical Director, Buenos Aires, talks during the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  5. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Conrado Varotto, CONAE Executive and Technical Director, Buenos Aires, looks on as other panelest speak during the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  6. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Hector Timerman, Foreign Minister of Argentina, Buenos Aires, talks during the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  7. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Michael Freilich, NASA Earth Science Division Director, NASA Headquarters, talks during the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  8. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Charles Gay, Deputy Associate Administrator, NASA Science Mission Directorate, talks during the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  9. Successful ShakeAlert Performance for the Napa Quake

    NASA Astrophysics Data System (ADS)

    Allen, R. M.; Given, D. D.; Heaton, T. H.; Vidale, J. E.

    2014-12-01

    ShakeAlert, the demonstration earthquake early warning system, developed by the USGS, UC Berkeley, Caltech, ETH, and the University of Washington, functioned as expected for the August 24, 2014, M6.0 Napa earthquake. The first ShakeAlert was generated by the ElarmS algorithm 5.1 sec after the origin time of the earthquake, and 3.3 sec after the P-wave arrived at the closest station 6.5 km from the epicenter. This initial alert, based on P-wave triggers from four stations, estimated the magnitude to be 5.7. The warning was received at the UC Berkeley Seismological Laboratory 5 seconds before the S-wave and about 10 sec prior to the onset of the strongest shaking. ShakeAlert beta-testers across the San Francisco Bay Area simultaneously received the alert, including the San Francisco 911 center with 8 sec warning, and the BART train system. BART has implemented an automated train-stopping system that was activated (although no trains were running at 3:20 am). With the available network geometry and communications, the blind zone of the first alert had a radius of 16 km. The four stations that contributed to the first alert all encapsulate data into 1-second packets, but the latency in transmitting data to the processing center ranged from 0.27 to 2.62 seconds. If all the stations were to deliver data in 0.27 seconds, then the alert would have been available 2.3 sec sooner and the blind zone would be reduced to about 8 km. This would also mean that the city of Napa would have received about 1 second of warning. The magnitude estimate and event location were accurate from the initial alert onwards. The magnitude estimate did first increase to 5.8 and then dip to 5.4 2.6 sec after the initial alert, stayed at that level for 2 sec, and then returned to 5.7. The final magnitude estimate was 6.0, consistent with the ANSS catalog.

  10. Sleep, alertness and alertness management among commercial airline pilots on short-haul and long-haul flights.

    PubMed

    Sallinen, Mikael; Sihvola, Maria; Puttonen, Sampsa; Ketola, Kimmo; Tuori, Antti; Härmä, Mikko; Kecklund, Göran; Åkerstedt, Torbjörn

    2017-01-01

    Airline pilots' sleep and on-duty alertness are important focus areas in commercial aviation. Until now, studies pertaining to this topic have mainly focused on specific characteristics of flights and thus a comprehensive picture of the matter is not well established. In addition, research knowledge of what airline pilots actually do to maintain their alertness while being on duty is scarce. To address these gaps in research knowledge, we conducted a field study on a representative sample of the airline pilots of a medium-sized airline. The sample consisted of 90 pilots, of whom 30 flew long-haul (LH) routes, 30 short-haul (SH) routes, and 30 flew both. A total of 86 pilots completed the measurements that lasted for almost two months per pilot. The measurements resulted in a total of 965 flight duty periods (FDPs) including SH flights and 627 FDPs including LH flights. During the measurement periods, sleep was measured by a diary and actigraphs, on-duty alertness by the Karolinska Sleepiness Scale (KSS) in all flight phases, and on-duty alertness management strategies by the diary. Results showed that SH and LH FDPs covering the whole domicile night (00:00-06:00 at home base) were most consistently associated with reduced sleep-wake ratio and subjective alertness. Approximately every 3rd FDP falling into this category involved a reduced sleep-wake ratio (1:3 or lower) and every 2nd a reduced level of subjective alertness (KSS rating 8-9 in at least one flight phase). The corresponding frequencies for the SH and LH FDPs that partly covered the domicile night were every 10th and every 5th FDP and for the pure non-night FDPs every 30th and every 36th FDP, respectively. The results also showed that the pilots tended to increase the use of effective on-duty alertness management strategies (consuming alertness-promoting products and taking strategic naps) in connection with the FDPs that overlapped the domicile night. Finally, the results showed that the frequency of

  11. Flood warnings in coastal areas: how do experience and information influence responses to alert services?

    NASA Astrophysics Data System (ADS)

    Pescaroli, G.; Magni, M.

    2015-04-01

    Many studies discuss the economic and technical aspects of flood warnings. Less attention has been given to the social and behavioural patterns that affect alert services. In particular, the literature focuses on warnings activated in river basins or marine environments without providing clear evidence on Mediterranean coastal areas, even though these are subjected to growing flood risk related to climate change. This paper is a first attempt to bridge this gap. Our research develops an in-depth analysis of the village of Cesenatico on the Adriatic Sea coast. Here the municipality adopted two complementary warning systems: a siren and an alert via short message service (SMS). The analysis focuses on a survey conducted in 2011 and 2012 with 228 participants. The relationships between social and behavioural variables and warning services are investigated as well as flood preparedness and information dissemination. Qualitative evidence from informal interviews is used to support the understanding of key responses. The conclusions show how different social and behavioural patterns can influence the effectiveness and use of warning systems, regardless of the technology adopted and the structural mitigation measures implemented. Education, training and accountability are seen to be critical elements for implementation. Finally, the statistical output is used to suggest new questions and new directions for research.

  12. Visual Alert System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    A visual alert system resulted from circuitry developed by Applied Cybernetics Systems for Langley as part of a space related telemetry system. James Campman, Applied Cybernetics president, left the company and founded Grace Industries, Inc. to manufacture security devices based on the Langley technology. His visual alert system combines visual and audible alerts for hearing impaired people. The company also manufactures an arson detection device called the electronic nose, and is currently researching additional applications of the NASA technology.

  13. The PIKfyve–ArPIKfyve–Sac3 triad in human breast cancer: Functional link between elevated Sac3 phosphatase and enhanced proliferation of triple negative cell lines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikonomov, Ognian C., E-mail: oikonomo@med.wayne.edu; Filios, Catherine, E-mail: cfilios@med.wayne.edu; Sbrissa, Diego, E-mail: dsbrissa@med.wayne.edu

    2013-10-18

    Highlights: •We assess PAS complex proteins and phosphoinositide levels in breast cancer cells. •Sac3 and ArPIKfyve are markedly elevated in triple-negative breast cancer cells. •Sac3 silencing inhibits proliferation in triple-negative breast cancer cell lines. •Phosphoinositide profiles are altered in breast cancer cells. •This is the first evidence linking high Sac3 with breast cancer cell proliferation. -- Abstract: The phosphoinositide 5-kinase PIKfyve and 5-phosphatase Sac3 are scaffolded by ArPIKfyve in the PIKfyve–ArPIKfyve–Sac3 (PAS) regulatory complex to trigger a unique loop of PtdIns3P–PtdIns(3,5)P{sub 2} synthesis and turnover. Whereas the metabolizing enzymes of the other 3-phosphoinositides have already been implicated in breast cancer,more » the role of the PAS proteins and the PtdIns3P–PtdIns(3,5)P{sub 2} conversion is unknown. To begin elucidating their roles, in this study we monitored the endogenous levels of the PAS complex proteins in cell lines derived from hormone-receptor positive (MCF7 and T47D) or triple-negative breast cancers (TNBC) (BT20, BT549 and MDA-MB-231) as well as in MCF10A cells derived from non-tumorigenic mastectomy. We report profound upregulation of Sac3 and ArPIKfyve in the triple negative vs. hormone-sensitive breast cancer or non-tumorigenic cells, with BT cell lines showing the highest levels. siRNA-mediated knockdown of Sac3, but not that of PIKfyve, significantly inhibited proliferation of BT20 and BT549 cells. In these cells, knockdown of ArPIKfyve had only a minor effect, consistent with a primary role for Sac3 in TNBC cell proliferation. Intriguingly, steady-state levels of PtdIns(3,5)P{sub 2} in BT20 and T47D cells were similar despite the 6-fold difference in Sac3 levels between these cell lines. However, steady-state levels of PtdIns3P and PtdIns5P, both regulated by the PAS complex, were significantly reduced in BT20 vs. T47D or MCF10A cell lines, consistent with elevated Sac3 affecting

  14. Alert status of nuclear weapons

    NASA Astrophysics Data System (ADS)

    Kristensen, Hans M.

    2017-11-01

    Nuclear Alert Forces. Four nuclear-armed states deploy nuclear warheads on alert, ready to be used on relatively short notice: United States, Russia, France and Britain. Combined, the four countries deploy an estimated 1,869 nuclear alert warheads. Russia and the United States deploy 1,749 alert warheads combined, or 94% of all alert warheads. Despite some debate about possible need to increase readiness of nuclear forces (China, Pakistan), the five other nuclear-armed states (China, Pakistan, India, Israel and North Korea) are thought to store their warheads separate from launchers under normal circumstances. The overall number of alert warheads has remained relatively stable during the past five years.

  15. 71. SAC command post construction, building 500, January 20, 1987 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    71. SAC command post construction, building 500, January 20, 1987 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  16. 66. SAC command post lobby, building 500, undated, looking southeast ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    66. SAC command post lobby, building 500, undated, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  17. 63. Aerial view of SAC command post construction, looking west ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    63. Aerial view of SAC command post construction, looking west - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  18. 69. Vice President Ford entering SAC command post, February, 1974 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    69. Vice President Ford entering SAC command post, February, 1974 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  19. Optimizing drug-dose alerts using commercial software throughout an integrated health care system.

    PubMed

    Saiyed, Salim M; Greco, Peter J; Fernandes, Glenn; Kaelber, David C

    2017-11-01

    All default electronic health record and drug reference database vendor drug-dose alerting recommendations (single dose, daily dose, dose frequency, and dose duration) were silently turned on in inpatient, outpatient, and emergency department areas for pediatric-only and nonpediatric-only populations. Drug-dose alerts were evaluated during a 3-month period. Drug-dose alerts fired on 12% of orders (104 098/834 911). System-level and drug-specific strategies to decrease drug-dose alerts were analyzed. System-level strategies included: (1) turning off all minimum drug-dosing alerts, (2) turning off all incomplete information drug-dosing alerts, (3) increasing the maximum single-dose drug-dose alert threshold to 125%, (4) increasing the daily dose maximum drug-dose alert threshold to 125%, and (5) increasing the dose frequency drug-dose alert threshold to more than 2 doses per day above initial threshold. Drug-specific strategies included changing drug-specific maximum single and maximum daily drug-dose alerting parameters for the top 22 drug categories by alert frequency. System-level approaches decreased alerting to 5% (46 988/834 911) and drug-specific approaches decreased alerts to 3% (25 455/834 911). Drug-dose alerts varied between care settings and patient populations. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Divers Alert Network

    MedlinePlus

    ... is Your Dive Safety Association Divers Alert Network DAN is Divers Alert Network, the diving industry’s largest ... Serving scuba divers for more than 30 years, DAN provides emergency assistance, medical information resources, educational opportunities ...

  1. 62. Aerial view of SAC command post, building 500, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    62. Aerial view of SAC command post, building 500, looking east - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  2. 13. SAC command center, weather center, underground structure, building 501, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. SAC command center, weather center, underground structure, building 501, undated - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  3. Alert Exchange Process Protocol

    NASA Technical Reports Server (NTRS)

    Groen, Frank

    2015-01-01

    The National Aeronautics and Space Administration of the United States of America (NASA), and the European Space Agency (ESA), and the Japanese Aerospace Exploration Agency (JAXA), acknowledging that NASA, ESA and JAXA have a mutual interest in exchanging Alerts and Alert Status Lists to enhance the information base for each system participant while fortifying the general level of cooperation between the policy agreement subscribers, and each Party will exchange Alert listings on regular basis and detailed Alert information on a need to know basis to the extent permitted by law.

  4. 67. Aerial view of SAC command post, building 500, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    67. Aerial view of SAC command post, building 500, looking northeast, undated - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  5. 64. SAC command post lobby, building 500, November 8, 1956, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    64. SAC command post lobby, building 500, November 8, 1956, looking east - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  6. 61. SAC control center command post construction, March 2, 1956, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    61. SAC control center command post construction, March 2, 1956, looking northeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  7. 4. Sac shield at entry of command center, building 501, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. Sac shield at entry of command center, building 501, looking west - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  8. 3. Threequarter view of building 500 looking southeast from SAC ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Three-quarter view of building 500 looking southeast from SAC Boulevard - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  9. 60. SAC emblem on side of missile, front lawn, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    60. SAC emblem on side of missile, front lawn, building 500, looking west - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  10. 68. Aerial view of SAC command post, building 500, looking ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    68. Aerial view of SAC command post, building 500, looking northeast, spring, 1957 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  11. Aquarius/SAC-D Observatory Being Crated for Shipment to Brazil

    NASA Image and Video Library

    2011-04-19

    NASA Aquarius/SAC-D being prepared for shipment to Brazil National Institute for Space Research Integration and Testing Lab. At INPE, the Aquarius/SAC-D observatory will undergo its final environmental testing.

  12. 49. SAC Chief of Staff office, second floor, Awing, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    49. SAC Chief of Staff office, second floor, A-wing, building 500, looking northwest - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  13. 46. SAC Commander in Chief entry, second floor, Awing, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. SAC Commander in Chief entry, second floor, A-wing, building 500, looking north - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  14. 47. SAC Commander in Chief office, second floor, Awing, building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. SAC Commander in Chief office, second floor, A-wing, building 500, looking northwest - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  15. 43. Main entry to SAC Control offices, second floor, Awing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. Main entry to SAC Control offices, second floor, A-wing, building 500, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  16. 8. SAC command center underground structure, building 501, basement entry, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. SAC command center underground structure, building 501, basement entry, machine room, April 11, 1955 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Command Center, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  17. 48. SAC Deputy Commander in Chief office, second floor, Awing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. SAC Deputy Commander in Chief office, second floor, A-wing, building 500, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  18. 65. SAC Minuteman Missile "shell", mounted for permanent display in ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    65. SAC Minuteman Missile "shell", mounted for permanent display in front lawn, building 500, looking east - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  19. Prioritizing earthquake and tsunami alerting efforts

    NASA Astrophysics Data System (ADS)

    Allen, R. M.; Allen, S.; Aranha, M. A.; Chung, A. I.; Hellweg, M.; Henson, I. H.; Melgar, D.; Neuhauser, D. S.; Nof, R. N.; Strauss, J. A.

    2015-12-01

    The timeline of hazards associated with earthquakes ranges from seconds for the strong shaking at the epicenter, to minutes for strong shaking at more distant locations in big quakes, to tens of minutes for a local tsunami. Earthquake and tsunami warning systems must therefore include very fast initial alerts, while also taking advantage of available time in bigger and tsunami-generating quakes. At the UC Berkeley Seismological Laboratory we are developing a suite of algorithms to provide the fullest possible information about earthquake shaking and tsunami inundation from seconds to minutes after a quake. The E-larmS algorithm uses the P-wave to rapidly detect an earthquake and issue a warning. It is currently issuing alerts to test users in as little as 3 sec after the origin time. Development of a new waveform detector may lead to even faster alerts. G-larmS uses permanent deformation estimates from GNSS stations to estimate the geometry and extent of rupture underway providing more accurate ground shaking estimates in big (M>~7) earthquakes. It performed well in the M6.0 2014 Napa earthquake. T-larmS is a new algorithm designed to extend alert capabilities to tsunami inundation. Rapid estimates of source characteristics for subduction zones event can not only be used to warn of the shaking hazard, but also the local tsunami inundation hazard. These algorithms are being developed, implemented and tested with a focus on the western US, but are also now being tested in other parts of the world including Israel, Turkey, Korea and Chile. Beta users in the Bay Area are receiving the alerts and beginning to implement automated actions. They also provide feedback on users needs, which has led to the development of the MyEEW smartphone app. This app allows beta users to receive the alerts on their cell phones. All these efforts feed into our ongoing assessment of directions and priorities for future development and implementation efforts.

  20. Squamous cell carcinoma of the anal sacs in three dogs.

    PubMed

    Mellett, S; Verganti, S; Murphy, S; Bowlt, K

    2015-03-01

    Anal sac squamous cell carcinoma is rare in dogs. Five cases have been previously reported, treatment of which involved surgery alone. This report describes three further cases of canine anal sac squamous cell carcinoma which underwent medical (meloxicam) management alone, resulting in survival of up to seven months. No metastases were identified. Squamous cell carcinoma, although extremely uncommon, should be considered as a possible differential diagnosis when a dog is presented for investigation of an anal sac mass. © 2014 British Small Animal Veterinary Association.

  1. 72. SAC control center underground structure lower floor plan, drawing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    72. SAC control center underground structure lower floor plan, drawing number 32-02-03, dated 1 February 1955 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  2. Cul-de-Sac Kids

    ERIC Educational Resources Information Center

    Hochschild, Thomas R., Jr.

    2013-01-01

    Previous research indicates that adults who live on cul-de-sac streets are more likely to have positive experiences with neighbors than residents of other street types (Brown and Werner, 1985; Hochschild Jr, 2011; Mayo Jr, 1979; Willmott, 1963). The present research ascertains whether street design has an impact on children's neighborhood…

  3. The vocal sac of Hylodidae (Amphibia, Anura): Phylogenetic and functional implications of a unique morphology.

    PubMed

    Elias-Costa, Agustin J; Montesinos, Rachel; Grant, Taran; Faivovich, Julián

    2017-11-01

    Anuran vocal sacs are elastic chambers that recycle exhaled air during vocalizations and are present in males of most species of frogs. Most knowledge of the diversity of vocal sacs relates to external morphology; detailed information on internal anatomy is available for few groups of frogs. Frogs of the family Hylodidae, which is endemic to the Atlantic Forest of Brazil and adjacent Argentina and Paraguay, have three patterns of vocal sac morphology-that is, single, subgular; paired, lateral; and absent. The submandibular musculature and structure of the vocal sac mucosa (the internal wall of the vocal sac) of exemplar species of this family and relatives were studied. In contrast to previous accounts, we found that all species of Crossodactylus and Hylodes possess paired, lateral vocal sacs, with the internal mucosa of each sac being separate from the contralateral one. Unlike all other frogs for which data are available, the mucosa of the vocal sacs in these genera is not supported externally by the mm. intermandibularis and interhyoideus. Rather, the vocal sac mucosa projects through the musculature and is free in the submandibular lymphatic sac. The presence of paired, lateral vocal sacs, the internal separation of the sac mucosae, and their projection through the m. interhyoideus are synapomorphies of the family. Furthermore, the specific configuration of the m. interhyoideus allows asymmetric inflation of paired vocal sacs, a feature only reported in species of these diurnal, stream-dwelling frogs. © 2017 Wiley Periodicals, Inc.

  4. Intraoperative Sac Pressure Measurement During Endovascular Abdominal Aortic Aneurysm Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishibashi, Hiroyuki, E-mail: ishibash@aichi-med-u.ac.j; Ishiguchi, Tsuneo; Ohta, Takashi

    2010-10-15

    PurposeIntraoperative sac pressure was measured during endovascular abdominal aortic aneurysm repair (EVAR) to evaluate the clinical significance of sac pressure measurement.MethodsA microcatheter was placed in an aneurysm sac from the contralateral femoral artery, and sac pressure was measured during EVAR procedures in 47 patients. Aortic blood pressure was measured as a control by a catheter from the left brachial artery.ResultsThe systolic sac pressure index (SPI) was 0.87 {+-} 0.10 after main-body deployment, 0.63 {+-} 0.12 after leg deployment (P < 0.01), and 0.56 {+-} 0.12 after completion of the procedure (P < 0.01). Pulse pressure was 55 {+-} 21 mmHg,more » 23 {+-} 15 mmHg (P < 0.01), and 16 {+-} 12 mmHg (P < 0.01), respectively. SPI showed no significant differences between the Zenith and Excluder stent grafts (0.56 {+-} 0.13 vs. 0.54 {+-} 0.10, NS). Type I endoleak was found in seven patients (15%), and the SPI decreased from 0.62 {+-} 0.10 to 0.55 {+-} 0.10 (P = 0.10) after fixing procedures. Type II endoleak was found in 12 patients (26%) by completion angiography. The SPI showed no difference between type II endoleak positive and negative (0.58 {+-} 0.12 vs. 0.55 {+-} 0.12, NS). There were no significant differences between the final SPI of abdominal aortic aneurysms in which the diameter decreased in the follow-up and that of abdominal aortic aneurysms in which the diameter did not change (0.53 {+-} 0.12 vs. 0.57 {+-} 0.12, NS).ConclusionsSac pressure measurement was useful for instant hemodynamic evaluation of the EVAR procedure, especially in type I endoleaks. However, on the basis of this small study, the SPI cannot be used to reliably predict sac growth or regression.« less

  5. 49 CFR 229.140 - Alerters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... alerters shall provide an audio alarm upon expiration of the timing cycle interval. An alerter on a... indication to the operator at least five seconds prior to an audio alarm. The visual indication on an alerter...

  6. Functional organization of area V2 in the alert macaque.

    PubMed

    Peterhans, E; von der Heydt, R

    1993-05-01

    We studied the relation between anatomical structure and functional properties of cells in area V2 of the macaque. Visual function was assessed in the alert animal during fixation of gaze. Recording sites were reconstructed with respect to cortical lamination and the cytochrome oxidase pattern. We measured orientation and direction selectivity, end-stopping, sensitivity to binocular disparity and ocular dominance, and determined more complex functions like sensitivity to anomalous contours and lines defined by coherent motion. Orientation selectivity was found in all parts of area V2, with high frequencies in the pale and thick stripes of the cytochrome oxidase pattern, and with lower frequency in the thin stripes. Representations of anomalous contours were found in the pale and thick stripes with similar frequencies, but generally not in the thin stripes, which have been thought to process colour. Lines defined by coherent motion were most frequently represented in the thick stripes; they were less frequent in the pale stripes, and (as with anomalous contours) were not found in the thin stripes. Sensitivity to binocular disparity was found in all types of stripes, but more frequently in the thick stripes, where the exclusively binocular neurons were also concentrated. By contrast, no segregation was found for direction selectivity and end-stopping. All neuronal properties were distributed evenly across cortical laminae. We conclude that mechanisms for figure-ground segregation involve the pale and the thick stripes of the cytochrome oxidase pattern, perhaps with greater emphasis on 'shape from motion' and 'stereoscopic depth' in the thick stripes, while more elementary neuronal properties are distributed almost evenly across the stripe pattern.

  7. AmberAlert / DPS / DHSEM / AAB

    Science.gov Websites

    cooperative public service alert to aid in the safe recovery of abducted children. The Alaska AMBER Alert children to aid in their safe return. AMBER Alert Hotline: 866-AKAMBER - (866-252-6237) State of Alaska

  8. pH sensing via bicarbonate-regulated “soluble” adenylyl cyclase (sAC)

    PubMed Central

    Rahman, Nawreen; Buck, Jochen; Levin, Lonny R.

    2013-01-01

    Soluble adenylyl cyclase (sAC) is a source of the second messenger cyclic adenosine 3′, 5′ monophosphate (cAMP). sAC is directly regulated by bicarbonate (HCO−3) ions. In living cells, HCO−3 ions are in nearly instantaneous equilibrium with carbon dioxide (CO2) and pH due to the ubiquitous presence of carbonic anhydrases. Numerous biological processes are regulated by CO2, HCO−3, and/or pH, and in a number of these, sAC has been shown to function as a physiological CO2/HCO3/pH sensor. In this review, we detail the known pH sensing functions of sAC, and we discuss two highly-studied, pH-dependent pathways in which sAC might play a role. PMID:24324443

  9. 85. Command HQ. SAC control center (MOD) new work cross ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    85. Command HQ. SAC control center (MOD) new work cross section, drawing number AW-30-02-07, dated 7 February, 1962 - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  10. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Hector Timerman, Foreign Minister of Argentina, Buenos Aires, left, Michael Freilich, NASA Earth Science Division Director, NASA Headquarters, Washington, center, and Conrado Varotto, CONAE Executive and Technical Director, Buenos Aires, laugh at the start of the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  11. Ovarian yolk sac tumour in a girl - case report.

    PubMed

    Sharma, Charu; Shah, Hemanshi; Sisodiya Shenoy, Neha; Makhija, Deepa; Waghmare, Mukta

    2017-01-01

    Yolk sac tumours are rare ovarian malignancies accounting for less than 1% of malignant ovarian germ cell tumours. They are mostly seen in adolescents and young women and are usually unilateral making fertility preservation imperative. Raised alpha-feto protein level is the hallmark of this tumour. We describe stage III yolk sac tumour in a girl child.

  12. Hernia sac of indirect inguinal hernia: invagination, excision, or ligation?

    PubMed

    Othman, I; Hady, H A

    2014-04-01

    This study compares the effect of invaginating excision of hernia sac without ligation with the traditional method of high ligation of the hernia sac on postoperative pain and recurrence. This multicenter prospective randomized study included 152 patients with 167 primary indirect inguinal hernias. In group I (54 hernias), the sac was not opened and was inverted with the finger into the peritoneal cavity. In group E (56 hernias), the sac was excised at the neck without ligation. In group L (57 hernias), the sac was transfixed at the neck and excised in the traditional manner. The repair of the posterior wall of the inguinal canal was done according to Lichtenstein tension-free technique. Mean length of follow-up was 81.50 ± 22.34, 79.35 ± 26.76, and 77.83 ± 21.26 months, respectively. Postoperative seroma occurred in 1 patient (0.60%) in group E and 1 patient (0.60%) in group L. Surgical site infection occurred in 2 patients (1.20%) in group I, 1 patient (0.60%) in group E, and 2 patients (1.20%) in group L. Mean postoperative pain score was 3.04 ± 2.11, 3.98 ± 2.33 and 4.06 ± 2.43, respectively (p: 0.049). Chronic pain occurred in 3 patients in group I (1.80%), 3 patients in group E (1.80%), and 5 patients in group L (3.00%) (p: 0.749). The difference between the complications in three groups was statistically insignificant (p: 0.887). Hernia recurrence occurred in 3 patients (1.80%) in group I, 1 patient (0.60%) in group E, and 1 patient (0.60%) in group L (p: 0.429). Invagination and excision of the hernia sac do not have adverse effects on repair integrity. They limit the dissection and reduce the morbidity and risk of injury to the spermatic cord and surrounded structures. They are safer and more appropriate for repair of sliding hernia. Ligation of the hernia sac in inguinal hernia surgery is not only unnecessary and time consuming but also leads to increased postoperative pain. Recurrence rates are statistically unaffected by not ligating the sac.

  13. Optimizing the real-time ground level enhancement alert system based on neutron monitor measurements: Introducing GLE Alert Plus

    NASA Astrophysics Data System (ADS)

    Souvatzoglou, G.; Papaioannou, A.; Mavromichalaki, H.; Dimitroulakos, J.; Sarlanis, C.

    2014-11-01

    Whenever a significant intensity increase is being recorded by at least three neutron monitor stations in real-time mode, a ground level enhancement (GLE) event is marked and an automated alert is issued. Although, the physical concept of the algorithm is solid and has efficiently worked in a number of cases, the availability of real-time data is still an open issue and makes timely GLE alerts quite challenging. In this work we present the optimization of the GLE alert that has been set into operation since 2006 at the Athens Neutron Monitor Station. This upgrade has led to GLE Alert Plus, which is currently based upon the Neutron Monitor Database (NMDB). We have determined the critical values per station allowing us to issue reliable GLE alerts close to the initiation of the event while at the same time we keep the false alert rate at low levels. Furthermore, we have managed to treat the problem of data availability, introducing the Go-Back-N algorithm. A total of 13 GLE events have been marked from January 2000 to December 2012. GLE Alert Plus issued an alert for 12 events. These alert times are compared to the alert times of GOES Space Weather Prediction Center and Solar Energetic Particle forecaster of the University of Málaga (UMASEP). In all cases GLE Alert Plus precedes the GOES alert by ≈8-52 min. The comparison with UMASEP demonstrated a remarkably good agreement. Real-time GLE alerts by GLE Alert Plus may be retrieved by http://cosray.phys.uoa.gr/gle_alert_plus.html, http://www.nmdb.eu, and http://swe.ssa.esa.int/web/guest/space-radiation. An automated GLE alert email notification system is also available to interested users.

  14. Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multisignal Vital Sign Monitoring Data.

    PubMed

    Chen, Lujie; Dubrawski, Artur; Wang, Donghan; Fiterau, Madalina; Guillame-Bert, Mathieu; Bose, Eliezer; Kaynar, Ata M; Wallace, David J; Guttendorf, Jane; Clermont, Gilles; Pinsky, Michael R; Hravnak, Marilyn

    2016-07-01

    The use of machine-learning algorithms to classify alerts as real or artifacts in online noninvasive vital sign data streams to reduce alarm fatigue and missed true instability. Observational cohort study. Twenty-four-bed trauma step-down unit. Two thousand one hundred fifty-three patients. Noninvasive vital sign monitoring data (heart rate, respiratory rate, peripheral oximetry) recorded on all admissions at 1/20 Hz, and noninvasive blood pressure less frequently, and partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were vital sign deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained machine-learning algorithms. The best model was evaluated on test set alerts to enact online alert classification over time. The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve performance of 0.79 (95% CI, 0.67-0.93) for peripheral oximetry at the instant the vital sign first crossed threshold and increased to 0.87 (95% CI, 0.71-0.95) at 3 minutes into the alerting period. Blood pressure area under the curve started at 0.77 (95% CI, 0.64-0.95) and increased to 0.87 (95% CI, 0.71-0.98), whereas respiratory rate area under the curve started at 0.85 (95% CI, 0.77-0.95) and increased to 0.97 (95% CI, 0.94-1.00). Heart rate alerts were too few for model development. Machine-learning models can discern clinically relevant peripheral oximetry, blood pressure, and respiratory rate alerts from artifacts in an online monitoring dataset (area under the curve > 0.87).

  15. The Evolutionary Economics of Embryonic-Sac Fluids in Squamate Reptiles.

    PubMed

    Bonnet, Xavier; Naulleau, Guy; Shine, Richard

    2017-03-01

    The parchment-shelled eggs of squamate reptiles take up substantial water from the nest environment, enabling the conversion of yolk into neonatal tissue and buffering the embryo against the possibility of subsequent dry weather. During development, increasing amounts of water are stored in the embryonic sacs (i.e., membranes around the embryo: amnion, allantois, and chorion). The evolution of viviparity (prolonged uterine retention of developing embryos) means that embryonic-sac fluid storage now imposes a cost (increased maternal burdening), confers less benefit (because the mother buffers fetal water balance), and introduces a potential conflict among uterine siblings (for access to finite water supplies). Our data on nine species of squamate reptiles and published information on three species show that the embryonic-sac fluids comprise around 33% of neonatal mass in viviparous species versus 94% in full-term eggs of oviparous squamates. Data on parturition in 149 vipers (Vipera aspis, a viviparous species) show that larger offspring store more fluids in their fetal sacs and that an increase in litter size is associated with a decrease in fluid-sac mass per offspring. Overall, the evolutionary transition from oviparity to viviparity may have substantially altered selective forces on offspring packaging and created competition among offspring for access to water reserves during embryonic development.

  16. ToxAlerts: a Web server of structural alerts for toxic chemicals and compounds with potential adverse reactions.

    PubMed

    Sushko, Iurii; Salmina, Elena; Potemkin, Vladimir A; Poda, Gennadiy; Tetko, Igor V

    2012-08-27

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly

  17. ToxAlerts: A Web Server of Structural Alerts for Toxic Chemicals and Compounds with Potential Adverse Reactions

    PubMed Central

    2012-01-01

    The article presents a Web-based platform for collecting and storing toxicological structural alerts from literature and for virtual screening of chemical libraries to flag potentially toxic chemicals and compounds that can cause adverse side effects. An alert is uniquely identified by a SMARTS template, a toxicological endpoint, and a publication where the alert was described. Additionally, the system allows storing complementary information such as name, comments, and mechanism of action, as well as other data. Most importantly, the platform can be easily used for fast virtual screening of large chemical datasets, focused libraries, or newly designed compounds against the toxicological alerts, providing a detailed profile of the chemicals grouped by structural alerts and endpoints. Such a facility can be used for decision making regarding whether a compound should be tested experimentally, validated with available QSAR models, or eliminated from consideration altogether. The alert-based screening can also be helpful for an easier interpretation of more complex QSAR models. The system is publicly accessible and tightly integrated with the Online Chemical Modeling Environment (OCHEM, http://ochem.eu). The system is open and expandable: any registered OCHEM user can introduce new alerts, browse, edit alerts introduced by other users, and virtually screen his/her data sets against all or selected alerts. The user sets being passed through the structural alerts can be used at OCHEM for other typical tasks: exporting in a wide variety of formats, development of QSAR models, additional filtering by other criteria, etc. The database already contains almost 600 structural alerts for such endpoints as mutagenicity, carcinogenicity, skin sensitization, compounds that undergo metabolic activation, and compounds that form reactive metabolites and, thus, can cause adverse reactions. The ToxAlerts platform is accessible on the Web at http://ochem.eu/alerts, and it is constantly

  18. Sediment‐associated organic matter sources and sediment oxygen demand in a Special Area of Conservation (SAC): A case study of the River Axe, UK

    PubMed Central

    Zhang, Y.; McMillan, S.; Dixon, E. R.; Stringfellow, A.; Bateman, S.; Sear, D. A.

    2017-01-01

    Abstract Oxygen demand in river substrates providing important habitats for the early life stages of aquatic ecology, including lithophilous fish, can arise due to the oxidation of sediment‐associated organic matter. Oxygen depletion associated with this component of river biogeochemical cycling, will, in part, depend on the sources of such material. A reconnaissance survey was therefore undertaken to assess the relative contributions from bed sediment‐associated organic matter sources potentially impacting on the River Axe Special Area of Conservation (SAC), in SW England. Source fingerprinting, including Monte Carlo uncertainty analysis, suggested that the relative frequency‐weighted average median source contributions ranged between 19% (uncertainty range 0–82%) and 64% (uncertainty range 0–99%) for farmyard manures or slurries, 4% (uncertainty range 0–49%) and 35% (uncertainty range 0–100%) for damaged road verges, 2% (uncertainty range 0–100%) and 68% (uncertainty range 0–100%) for decaying instream vegetation, and 2% (full uncertainty range 0–15%) and 6% (uncertainty range 0–48%) for human septic waste. A reconnaissance survey of sediment oxygen demand (SOD) along the channel designated as a SAC yielded a mean SOD5 of 4 mg O2 g−1 dry sediment and a corresponding SOD20 of 7 mg O2 g−1 dry sediment, compared with respective ranges of 1–15 and 2–30 mg O2 g−1 dry sediment, measured by the authors for a range of river types across the UK. The findings of the reconnaissance survey were used in an agency (SW region) catchment appraisal exercise for informing targeted management to help protect the SAC. PMID:29527135

  19. Contributors to Frequent Telehealth Alerts Including False Alerts for Patients with Heart Failure: A Mixed Methods Exploration

    PubMed Central

    Radhakrishna, K.; Bowles, K.; Zettek-Sumner, A.

    2013-01-01

    Summary Background Telehealth data overload through high alert generation is a significant barrier to sustained adoption of telehealth for managing HF patients. Objective To explore the factors contributing to frequent telehealth alerts including false alerts for Medicare heart failure (HF) patients admitted to a home health agency. Materials and Methods A mixed methods design that combined quantitative correlation analysis of patient characteristic data with number of telehealth alerts and qualitative analysis of telehealth and visiting nurses’ notes on follow-up actions to patients’ telehealth alerts was employed. All the quantitative and qualitative data was collected through retrospective review of electronic records of the home heath agency. Results Subjects in the study had a mean age of 83 (SD = 7.6); 56% were female. Patient co-morbidities (p<0.05) of renal disorders, anxiety, and cardiac arrhythmias emerged as predictors of telehealth alerts through quantitative analysis (n = 168) using multiple regression. Inappropriate telehealth measurement technique by patients (54%) and home healthcare system inefficiencies (37%) contributed to most telehealth false alerts in the purposive qualitative sub-sample (n = 35) of patients with high telehealth alerts. Conclusion Encouraging patient engagement with the telehealth process, fostering a collaborative approach among all the clinicians involved with the telehealth intervention, tailoring telehealth alert thresholds to patient characteristics along with establishing patient-centered telehealth outcome goals may allow meaningful generation of telehealth alerts. Reducing avoidable telehealth alerts could vastly improve the efficiency and sustainability of telehealth programs for HF management. PMID:24454576

  20. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    From left, George Diller, NASA Public Affairs Officer; Charles Gay, Deputy Associate Administrator, NASA Science Mission Directorate; Hector Timerman, Foreign Minister of Argentina, Buenos Aires; Michael Freilich, NASA Earth Science Division Director, NASA Headquarters; and Conrado Varotto, CONAE Executive and Technical Director, Buenos Aires, are seen at the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  1. Aquarius SAC-D Post-Launch Briefing

    NASA Image and Video Library

    2011-06-10

    Seated from left, George Diller, NASA Public Affairs Officer; Charles Gay, Deputy Associate Administrator, NASA Science Mission Directorate; Hector Timerman, Foreign Minister of Argentina, Buenos Aires; Michael Freilich, NASA Earth Science Division Director, NASA Headquarters; and Conrado Varotto, CONAE Executive and Technical Director, Buenos Aires, are seen at the Aquarius/SAC-D post-launch press conference on Friday, June 10, 2011 at the NASA Resident Office, Vandenberg Air Force Base, Calif. The joint U.S./Argentinian Aquarius/Satélite de Aplicaciones Científicas (SAC)-D mission, launched earlier on Friday June 10, will map the salinity at the ocean surface, information critical to improving our understanding of two major components of Earth's climate system: the water cycle and ocean circulation. Photo Credit: (NASA/Bill Ingalls)

  2. Alarms about structural alerts.

    PubMed

    Alves, Vinicius; Muratov, Eugene; Capuzzi, Stephen; Politi, Regina; Low, Yen; Braga, Rodolpho; Zakharov, Alexey V; Sedykh, Alexander; Mokshyna, Elena; Farag, Sherif; Andrade, Carolina; Kuz'min, Victor; Fourches, Denis; Tropsha, Alexander

    2016-08-21

    Structural alerts are widely accepted in chemical toxicology and regulatory decision support as a simple and transparent means to flag potential chemical hazards or group compounds into categories for read-across. However, there has been a growing concern that alerts disproportionally flag too many chemicals as toxic, which questions their reliability as toxicity markers. Conversely, the rigorously developed and properly validated statistical QSAR models can accurately and reliably predict the toxicity of a chemical; however, their use in regulatory toxicology has been hampered by the lack of transparency and interpretability. We demonstrate that contrary to the common perception of QSAR models as "black boxes" they can be used to identify statistically significant chemical substructures (QSAR-based alerts) that influence toxicity. We show through several case studies, however, that the mere presence of structural alerts in a chemical, irrespective of the derivation method (expert-based or QSAR-based), should be perceived only as hypotheses of possible toxicological effect. We propose a new approach that synergistically integrates structural alerts and rigorously validated QSAR models for a more transparent and accurate safety assessment of new chemicals.

  3. Sensor Alerting Capability

    NASA Astrophysics Data System (ADS)

    Henriksson, Jakob; Bermudez, Luis; Satapathy, Goutam

    2013-04-01

    There is a large amount of sensor data generated today by various sensors, from in-situ buoys to mobile underwater gliders. Providing sensor data to the users through standardized services, language and data model is the promise of OGC's Sensor Web Enablement (SWE) initiative. As the amount of data grows it is becoming difficult for data providers, planners and managers to ensure reliability of data and services and to monitor critical data changes. Intelligent Automation Inc. (IAI) is developing a net-centric alerting capability to address these issues. The capability is built on Sensor Observation Services (SOSs), which is used to collect and monitor sensor data. The alerts can be configured at the service level and at the sensor data level. For example it can alert for irregular data delivery events or a geo-temporal statistic of sensor data crossing a preset threshold. The capability provides multiple delivery mechanisms and protocols, including traditional techniques such as email and RSS. With this capability decision makers can monitor their assets and data streams, correct failures or be alerted about a coming phenomena.

  4. Age and egg-sac loss determine maternal behaviour and locomotor activity of wolf spiders (Araneae, Lycosidae).

    PubMed

    Ruhland, Fanny; Chiara, Violette; Trabalon, Marie

    2016-11-01

    Wolf spiders' (Lycosidae) maternal behaviour includes a specific phase called "egg brooding" which consists of guarding and carrying an egg-sac throughout the incubation period. The transport of an egg-sac can restrict mothers' exploratory and locomotor activity, in particular when foraging. The present study details the ontogeny of maternal behaviour and assesses the influence of age of egg-sac (or embryos' developmental stage) on vagrant wolf spider Pardosa saltans females' exploration and locomotion. We observed these spiders' maternal behaviour in the laboratory and evaluated their locomotor activity using a digital activity recording device. Our subjects were virgin females (without egg-sac) and first time mothers (with her egg-sac) who were divided into three groups. The first group of mothers were tested on the day the egg-sac was built (day 0), and the females of the other two groups were tested 10 or 15days after they had built their egg-sac. We evaluated the effects of the presence and the loss of egg-sac on mothers' activity. Pardosa saltans females' behaviour depended on mothers' physiological state and/or age of egg-sac (developmental stage of embryos). Virgin females' behaviour was not modified by the presence of an egg-sac in their environment. Mothers' reactions to the presence, the loss and the recovery of their egg-sac varied during the maternal cycle. Maternal behaviour changed with age of egg-sac, but the levels of locomotor activity of mothers with egg-sacs was similar to those of virgin females. Loss of egg-sac modified the maternal behaviour and locomotor activity of all mothers; these modifications were greater on "day 15" when embryos had emerged from eggs. All mothers were able to retrieve their egg-sacs and to re-attach them to their spinnerets. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Auditory alert systems with enhanced detectability

    NASA Technical Reports Server (NTRS)

    Begault, Durand R. (Inventor)

    2008-01-01

    Methods and systems for distinguishing an auditory alert signal from a background of one or more non-alert signals. In a first embodiment, a prefix signal, associated with an existing alert signal, is provided that has a signal component in each of three or more selected frequency ranges, with each signal component in each of three or more selected level at least 3-10 dB above an estimated background (non-alert) level in that frequency range. The alert signal may be chirped within one or more frequency bands. In another embodiment, an alert signal moves, continuously or discontinuously, from one location to another over a short time interval, introducing a perceived spatial modulation or jitter. In another embodiment, a weighted sum of background signals adjacent to each ear is formed, and the weighted sum is delivered to each ear as a uniform background; a distinguishable alert signal is presented on top of this weighted sum signal at one ear, or distinguishable first and second alert signals are presented at two ears of a subject.

  6. Transient Alerts in LSST

    NASA Astrophysics Data System (ADS)

    Kantor, J.

    During LSST observing, transient events will be detected and alerts generated at the LSST Archive Center at NCSA in Champaign-Illinois. As a very high rate of alerts is expected, approaching ˜ 10 million per night, we plan for VOEvent-compliant Distributor/Brokers (http://voevent.org) to be the primary end-points of the full LSST alert streams. End users will then use these Distributor/Brokers to classify and filter events on the stream for those fitting their science goals. These Distributor/Brokers are envisioned to be operated as a community service by third parties who will have signed MOUs with LSST. The exact identification of Distributor/Brokers to receive alerts will be determined as LSST approaches full operations and may change over time, but it is in our interest to identify and coordinate with them as early as possible. LSST will also operate a limited Distributor/Broker with a filtering capability at the Archive Center, to allow alerts to be sent directly to a limited number of entities that for some reason need to have a more direct connection to LSST. This might include, for example, observatories with significant follow-up capabilities whose observing may temporarily be more directly tied to LSST observing. It will let astronomers create simple filters that limit what alerts are ultimately forwarded to them. These user defined filters will be possible to specify using an SQL-like declarative language, or short snippets of (likely Python) code. We emphasize that this LSST-provided capability will be limited, and is not intended to satisfy the wide variety of use cases that a full-fledged public Event Distributor/Broker could. End users will not be able to subscribe to full, unfiltered, alert streams coming directly from LSST. In this session, we will discuss anticipated LSST data rates, and capabilities for alert processing and distribution/brokering. We will clarify what the LSST Observatory will provide versus what we anticipate will be a

  7. Medical alert bracelet (image)

    MedlinePlus

    People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will ... People with diabetes should always wear a medical alert bracelet or necklace that emergency medical workers will ...

  8. Evidence for Avian Intrathoracic Air Sacs in a New Predatory Dinosaur from Argentina

    PubMed Central

    Sereno, Paul C.; Martinez, Ricardo N.; Wilson, Jeffrey A.; Varricchio, David J.; Alcober, Oscar A.; Larsson, Hans C. E.

    2008-01-01

    Background Living birds possess a unique heterogeneous pulmonary system composed of a rigid, dorsally-anchored lung and several compliant air sacs that operate as bellows, driving inspired air through the lung. Evidence from the fossil record for the origin and evolution of this system is extremely limited, because lungs do not fossilize and because the bellow-like air sacs in living birds only rarely penetrate (pneumatize) skeletal bone and thus leave a record of their presence. Methodology/Principal Findings We describe a new predatory dinosaur from Upper Cretaceous rocks in Argentina, Aerosteon riocoloradensis gen. et sp. nov., that exhibits extreme pneumatization of skeletal bone, including pneumatic hollowing of the furcula and ilium. In living birds, these two bones are pneumatized by diverticulae of air sacs (clavicular, abdominal) that are involved in pulmonary ventilation. We also describe several pneumatized gastralia (“stomach ribs”), which suggest that diverticulae of the air sac system were present in surface tissues of the thorax. Conclusions/Significance We present a four-phase model for the evolution of avian air sacs and costosternal-driven lung ventilation based on the known fossil record of theropod dinosaurs and osteological correlates in extant birds: (1) Phase I—Elaboration of paraxial cervical air sacs in basal theropods no later than the earliest Late Triassic. (2) Phase II—Differentiation of avian ventilatory air sacs, including both cranial (clavicular air sac) and caudal (abdominal air sac) divisions, in basal tetanurans during the Jurassic. A heterogeneous respiratory tract with compliant air sacs, in turn, suggests the presence of rigid, dorsally attached lungs with flow-through ventilation. (3) Phase III—Evolution of a primitive costosternal pump in maniraptoriform theropods before the close of the Jurassic. (4) Phase IV—Evolution of an advanced costosternal pump in maniraptoran theropods before the close of the

  9. Sac Angiography and Glue Embolization in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koike, Yuya, E-mail: r06118@hotmail.co.jp; Nishimura, Jun-ichi, E-mail: jun-ichi-n@nifty.com; Hase, Soichiro, E-mail: haseman@hotmail.co.jp

    PurposeThe purpose of this study was to demonstrate a sac angiography technique and evaluate the feasibility of N-butyl cyanoacrylate (NBCA) embolization of the ruptured abdominal aortic aneurysm (AAA) sac in emergency endovascular aneurysm repair (EVAR) in hemodynamically unstable patients.MethodsA retrospective case series of three patients in whom sac angiography was performed during emergency EVAR for ruptured AAA was reviewed. After stent graft deployment, angiography within the sac of aneurysm (sac angiography) was performed by manually injecting 10 ml of contrast material through a catheter to identify the presence and site of active bleeding. In two patients, sac angiography revealed active extravasationmore » of the contrast material, and NBCA embolization with a coaxial catheter system was performed to achieve prompt sealing.ResultsSac angiography was successful in all three patients. In the two patients who underwent NBCA embolization for aneurysm sac bleeding, follow-up computed tomography (CT) images demonstrated the accumulation of NBCA consistent with the bleeding site in preprocedural CT images.ConclusionsEVAR is associated with a potential risk of ongoing bleeding from type II or IV endoleaks into the disrupted aneurysm sac in patients with severe coagulopathy. Therefore, sac angiography and NBCA embolization during emergency EVAR may represent a possible technical improvement in the treatment of ruptured AAA in hemodynamically unstable patients.« less

  10. Established and potential physiological roles of bicarbonate-sensing soluble adenylyl cyclase (sAC) in aquatic animals

    PubMed Central

    Tresguerres, Martin; Barott, Katie L.; Barron, Megan E.; Roa, Jinae N.

    2014-01-01

    Soluble adenylyl cyclase (sAC) is a recently recognized source of the signaling molecule cyclic AMP (cAMP) that is genetically and biochemically distinct from the classic G-protein-regulated transmembrane adenylyl cyclases (tmACs). Mammalian sAC is distributed throughout the cytoplasm and it may be present in the nucleus and inside mitochondria. sAC activity is directly stimulated by HCO3−, and sAC has been confirmed to be a HCO3− sensor in a variety of mammalian cell types. In addition, sAC can functionally associate with carbonic anhydrases to act as a de facto sensor of pH and CO2. The two catalytic domains of sAC are related to HCO3−-regulated adenylyl cyclases from cyanobacteria, suggesting the cAMP pathway is an evolutionarily conserved mechanism for sensing CO2 levels and/or acid/base conditions. Reports of sAC in aquatic animals are still limited but are rapidly accumulating. In shark gills, sAC senses blood alkalosis and triggers compensatory H+ absorption. In the intestine of bony fishes, sAC modulates NaCl and water absorption. And in sea urchin sperm, sAC may participate in the initiation of flagellar movement and in the acrosome reaction. Bioinformatics and RT-PCR results reveal that sAC orthologs are present in most animal phyla. This review summarizes the current knowledge on the physiological roles of sAC in aquatic animals and suggests additional functions in which sAC may be involved. PMID:24574382

  11. The COMESEP Alert System

    NASA Astrophysics Data System (ADS)

    Crosby, Norma; Veronig, Astrid; Rodriguez, Luciano; Vrsnak, Bojan; Vennerstrom, Susanne; Malandraki, Olga; Dalla, Silvia; Srivastava, Nandita; Hesse, Michael; Odstrcil, Dusan; Robbrecht, Eva

    2014-05-01

    Tools for forecasting geomagnetic storms and solar energetic particle (SEP) radiation storms have been developed under the three-year EU FP7 COMESEP (COronal Mass Ejections and Solar Energetic Particles) collaborative project. To enhance our understanding of the 3D kinematics and interplanetary propagation of coronal mass ejections (CMEs), the structure, propagation and evolution of CMEs have been investigated. In parallel, the sources and propagation of SEPs have been examined and modeled. During the third year of the COMESEP project the produced tools have been validated and implemented into an operational space weather alert system. The COMESEP Alert System provides notifications for the space weather community. To achieve this the system relies on both models and data, the latter including near real-time data as well as historical data. Geomagnetic and SEP radiation storm alerts are based on the COMESEP definition of risk. The COMESEP Alert System has recently been launched. Receiving COMESEP alerts are free of charge, but registration is required. For more information see the project website (http://www.comesep.eu/). This work has received funding from the European Commission FP7 Project COMESEP (263252).

  12. 38 CFR Appendix A to Part 41 - Data Collection Form (Form SF-SAC)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Data Collection Form (Form SF-SAC) A Appendix A to Part 41 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS.... Appendix A to Part 41—Data Collection Form (Form SF-SAC) Note: Data Collection Form SF-SAC and instructions...

  13. Adherence to drug-drug interaction alerts in high-risk patients: a trial of context-enhanced alerting.

    PubMed

    Duke, Jon D; Li, Xiaochun; Dexter, Paul

    2013-05-01

    Drug-drug interaction (DDI) alerting is an important form of clinical decision support, yet physicians often fail to attend to critical DDI warnings due to alert fatigue. We previously described a model for highlighting patients at high risk of a DDI by enhancing alerts with relevant laboratory data. We sought to evaluate the effect of this model on alert adherence in high-risk patients. A 6-month randomized controlled trial involving 1029 outpatient physicians was performed. The target interactions were all DDIs known to cause hyperkalemia. Alerts in the intervention group were enhanced with the patient's most recent potassium and creatinine levels. The control group received unmodified alerts. High -risk patients were those with baseline potassium >5.0 mEq/l and/or creatinine ≥1.5 mg/dl (132 μmol/l). We found no significant difference in alert adherence in high-risk patients between the intervention group (15.3%) and the control group (16.8%) (p=0.71). Adherence in normal risk patients was significantly lower in the intervention group (14.6%) than in the control group (18.6%) (p<0.01). In neither group did physicians increase adherence in patients at high risk. Physicians adhere poorly to hyperkalemia-associated DDI alerts even in patients with risk factors for a clinically significant interaction, and the display of relevant laboratory data in these alerts did not improve adherence levels in the outpatient setting. Further research is necessary to determine optimal strategies for conveying patient-specific DDI risk.

  14. Alert Triage v 0.1 beta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doak, Justin E.; Ingram, Joe; Johnson, Josh

    2016-01-06

    In the cyber security operations of a typical organization, data from multiple sources are monitored, and when certain conditions in the data are met, an alert is generated in an alert management system. Analysts inspect these alerts to decide if any deserve promotion to an event requiring further scrutiny. This triage process is manual, time-consuming, and detracts from the in-depth investigation of events. We have created a software system that uses supervised machine learning to automatically prioritize these alerts. In particular we utilize active learning to make efficient use of the pool of unlabeled alerts, thereby improving the performance ofmore » our ranking models over passive learning. We have demonstrated the effectiveness of our system on a large, real-world dataset of cyber security alerts.« less

  15. Yolk sac development in lizards (Lacertilia: Scincidae): New perspectives on the egg of amniotes.

    PubMed

    Stewart, James R; Thompson, Michael B

    2017-04-01

    Embryos of oviparous reptiles develop on the surface of a large mass of yolk, which they metabolize to become relatively large hatchlings. Access to the yolk is provided by tissues growing outward from the embryo to cover the surface of the yolk. A key feature of yolk sac development is a dedicated blood vascular system to communicate with the embryo. The best known model for yolk sac development and function of oviparous amniotes is based on numerous studies of birds, primarily domestic chickens. In this model, the vascular yolk sac forms the perimeter of the large yolk mass and is lined by a specialized epithelium, which takes up, processes and transports yolk nutrients to the yolk sac blood vessels. Studies of lizard yolk sac development, dating to more than 100 years ago, report characteristics inconsistent with this model. We compared development of the yolk sac from oviposition to near hatching in embryonic series of three species of oviparous scincid lizards to consider congruence with the pattern described for birds. Our findings reinforce results of prior studies indicating that squamate reptiles mobilize and metabolize the large yolk reserves in their eggs through a process unknown in other amniotes. Development of the yolk sac of lizards differs from birds in four primary characteristics, migration of mesoderm, proliferation of endoderm, vascular development and cellular diversity within the yolk sac cavity. Notably, all of the yolk is incorporated into cells relatively early in development and endodermal cells within the yolk sac cavity align along blood vessels which course throughout the yolk sac cavity. The pattern of uptake of yolk by endodermal cells indicates that the mechanism of yolk metabolism differs between lizards and birds and that the evolution of a fundamental characteristic of embryonic nutrition diverged in these two lineages. Attributes of the yolk sac of squamates reveal the existence of phylogenetic diversity among amniote lineages

  16. Molecular detection and in vitro antioxidant activity of S-allyl-L-cysteine (SAC) extracted from Allium sativum.

    PubMed

    Sun, Y-E; Wang, W-D

    2016-06-30

    It is well known that Allium sativum has potential applications to clinical treatment of various cancers due to its remarkable ability in eliminating free radicals and increasing metabolism. An allyl-substituted cysteine derivative - S-allyl-L-cysteine (SAC) was separated and identified from Allium sativum. The extracted SAC was reacted with 1-pyrenemethanol to obtain pyrene-labelled SAC (Py-SAC) to give SAC fluorescence properties. Molecular detection of Py-SAC was conducted by steady-state fluorescence spectroscopy and time-resolved fluorescence method to quantitatively measure concentrations of Py-SAC solutions. The ability of removing 1,1-diphenyl-2-picrylhydrazyl (DPPH) and hydroxyl radical using Py-SAC was determined through oxygen radical absorbance capacity (ORAC). Results showed the activity of Py-SAC and Vitamin C (VC) with ORAC as index, the concentrations of Py-SAC and VC were 58.43 mg/L and 5.72 mg/L respectively to scavenge DPPH, and 8.16 mg/L and 1.67 mg/L to scavenge •OH respectively. Compared with VC, the clearance rates of Py-SAC to scavenge DPPH were much higher, Py-SAC could inhibit hydroxyl radical. The ability of removing radical showed a dose-dependent relationship within the scope of the drug concentration.

  17. Anal sac tumours of the dog and their response to cytoreductive surgery and chemotherapy.

    PubMed

    Emms, S G

    2005-06-01

    A retrospective study of anal sac tumours without pulmonary metastases, from the author's clinical records for the period July 1989 to July 2002, was conducted to establish the response to treatment with surgery and melphalan chemotherapy. Of 21 dogs with tumours of the anal sacs 19 had apocrine gland adenocarcinomas of anal sac origin, one had a benign papillary cystadenoma and another had a malignant melanoma. Two of the 19 dogs had bilateral anal sac adenocarcinomas. Ten of the 19 dogs with apocrine gland adenocarcinomas of anal sac origin had sublumbar lymphadenopathy. Five dogs were excluded by their owners from recommended treatment. Fourteen dogs with apocrine gland adenocarcinomas of anal sac origin were treated by surgical cytoreduction and chemotherapy with melphalan. Seven of the 14 dogs had regional lymph node metastases. Cytoreduction was by local excision of the anal sac in all 14 dogs and concurrent removal of the sublumbar retroperitoneal lymph nodes in the seven dogs with regional lymph node metastases. The median survival time of dogs with sublumbar nodal metastasis was 20 months and for dogs with tumour localised to the anal sac the median survival time was 29.3 months. There was no difference in median survival of those dogs with sublumbar metastases compared to those without. This study suggests there is a role for melphalan in the treatment of dogs with anal sac adenocarcinoma when combined with cytoreductive surgery, with treatment survival times and the local recurrence rate of the primary tumour comparing favourably with previously published treatment regimes.

  18. Warning Alert HITL Experiment Results

    NASA Technical Reports Server (NTRS)

    Monk, Kevin J.; Ferm, Lisa; Roberts, Zach

    2018-01-01

    Minimum Operational Performance Standards (MOPS) are being developed to support the integration of Unmanned Aircraft Systems (UAS) in the National Airspace (NAS). Input from subject matter experts and multiple research studies have informed display requirements for Detect-and-Avoid (DAA) systems aimed at supporting timely and appropriate pilot responses to collision hazards. Phase 1 DAA MOPS alerting is designed to inform pilots if an avoidance maneuver is necessary; the two highest alert levels - caution and warning - indicate how soon pilot action is required and whether there is adequate time to coordinate with the air traffic controller (ATC). Additional empirical support is needed to clarify the extent to which warning-level alerting impacts DAA task performance. The present study explores the differential effects of the auditory and visual cues provided by the DAA Warning alert, and performance implications compared to caution-only alerting are discussed.

  19. SAC-C mission, an example of international cooperation

    NASA Astrophysics Data System (ADS)

    Colomb, F.; Alonso, C.; Hofmann, C.; Nollmann, I.

    In comp liance with the objectives established in the National Space Program, Argentina in Space 1997-2008 ((Plan Espacial Nacional, Argentina en el Espacio 1997-2008), the National Commission on Space Activities (Comisión Nacional de Actividades Espaciales - CONAE) undertook the design, construction, and launching of the SAC-C satellite in close collaboration with NASA. The purpose of this Mission is to carry out observations of interest both for the USA and Argentina, thus contributing effectively to NASA's Earth Science Program and to CONAE's National Space Program. The SAC-C is an international Earth observing satellite mission conceived as a partnership between CONAE and NASA, with additional support in instrumentation and satellite development from the Danish DSRI, the Italian ASI, the French CNES and the Brazilian INPE. A Delta II rocket successfully launched it on November 21st, 2000, from Vandenberg AFB, California, USA. Ten instruments on board the SAC-C perform different studies related to the ground and sea ecosystems, the atmosphere and the geomagnetic field. There are also technological experiments for determination of the satellite attitude and velocity as well as for the studies of the influence of space radiation on advanced electronic components . The inclusion of SAC-C in the AM Constellation, jointly with NASA satellites Landsat 7, EO 1 and Terra, is another example of important international cooperation which synergies the output of any single Mission. The Constellation has been working since March 2001 as a single mission and several cooperative activities have been undertaken including several jointly sponsored technical workshops and collaborative spacecraft navigation experiments. A flight campaign of the NASA AVIRIS instrument was performed in Argentine during January and February 2001, for calibration of SAC-C and EO 1 cameras and the development of joint scientific works. In Cordoba Space Center a jointly operated ground GPS reference

  20. Hernia Sac Presence Portends Better Survivability of Isolated Congenital Diaphragmatic Hernia with "Liver-Up".

    PubMed

    Grizelj, Ruža; Bojanić, Katarina; Vuković, Jurica; Novak, Milivoj; Weingarten, Toby N; Schroeder, Darrell R; Sprung, Juraj

    2017-04-01

    Objective  The objective of this study was to investigate the prognostic value of a hernia sac in isolated congenital diaphragmatic hernia (CDH) with intrathoracic liver herniation ("liver-up"). Study Design  A retrospective study from the single tertiary center. Isolated "liver-up" CDH neonates referred to our institution between 2000 and 2015 were reviewed for the presence or absence of a hernia sac. Association between the presence of a hernia sac and survival was assessed. Results  Over the study period, there were 29 isolated CDH patients with "liver-up" who were treated, 7 (24%) had a sac, and 22 (76%) did not. Demographics were similar between groups. However, disease acuity, assessed from lower Apgar scores ( p  = 0.044), lower probability of survival ( p  = 0.037), and lower admission oxygenation ( p  = 0.027), was higher in neonates without a sac. Hospital survival was significantly higher for those with sac compared with those without (7/7, 100 vs. 7/22, 32%, p  = 0.002). Conclusion  The presence of a hernia sac may be associated with better survival for isolated "liver-up" CDH. As the presence of sac can be prenatally detected, it may be a useful marker to aid perinatal decision making. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Integration of Golgi trafficking and growth factor signaling by the lipid phosphatase SAC1

    PubMed Central

    Blagoveshchenskaya, Anastasia; Cheong, Fei Ying; Rohde, Holger M.; Glover, Greta; Knödler, Andreas; Nicolson, Teresa; Boehmelt, Guido; Mayinger, Peter

    2008-01-01

    When a growing cell expands, lipids and proteins must be delivered to its periphery. Although this phenomenon has been observed for decades, it remains unknown how the secretory pathway responds to growth signaling. We demonstrate that control of Golgi phosphatidylinositol-4-phosphate (PI(4)P) is required for growth-dependent secretion. The phosphoinositide phosphatase SAC1 accumulates at the Golgi in quiescent cells and down-regulates anterograde trafficking by depleting Golgi PI(4)P. Golgi localization requires oligomerization of SAC1 and recruitment of the coat protein (COP) II complex. When quiescent cells are stimulated by mitogens, SAC1 rapidly shuttles back to the endoplasmic reticulum (ER), thus releasing the brake on Golgi secretion. The p38 mitogen-activated kinase (MAPK) pathway induces dissociation of SAC1 oligomers after mitogen stimulation, which triggers COP-I–mediated retrieval of SAC1 to the ER. Inhibition of p38 MAPK abolishes growth factor–induced Golgi-to-ER shuttling of SAC1 and slows secretion. These results suggest direct roles for p38 MAPK and SAC1 in transmitting growth signals to the secretory machinery. PMID:18299350

  2. Neuroendocrine carcinoma of the apocrine glands of the anal sac in a dog.

    PubMed

    Ogawa, Bunichiro; Taniai, Eriko; Hayashi, Hitomi; Imaoka, Masako; Machida, Noboru; Mitsumori, Kunitoshi; Shibutani, Makoto

    2011-07-01

    A perianal subcutaneous tumor involving the anal sac developed in an 8-year-old male mixed Labrador Retriever dog. Histologically, this tumor showed typical features of the solid-type carcinoma of the apocrine glands of the anal sac. However, neoplastic cells were immunoreactive for cytokeratin 8, chromogranin A, vasoactive intestinal peptide, neuron-specific enolase, and synaptophysin, and negative for S-100 protein, α-smooth muscle actin, vimentin, glucagon, insulin, somatostatin, carcinoembryonic antigen, serotonin, and parathyroid hormone-related protein. Considering the distribution of chromogranin A-positive cells within the anal sac apocrine glands, this tumor was diagnosed as neuroendocrine carcinoma originating from the apocrine glands of the anal sac.

  3. Enlarged Dural Sac in Idiopathic Bronchiectasis Implicates Heritable Connective Tissue Gene Variants

    PubMed Central

    Birchard, Katherine R.; Lowe, Jared R.; Patrone, Michael V.

    2016-01-01

    Rationale: Patients with idiopathic bronchiectasis are predominantly female and have an asthenic body morphotype and frequent nontuberculous mycobacterial respiratory infections. They also demonstrate phenotypic features (scoliosis, pectus deformity, mitral valve prolapse) that are commonly seen in individuals with heritable connective tissue disorders. Objectives: To determine whether lumbar dural sac size is increased in patients with idiopathic bronchiectasis as compared with control subjects, and to assess whether dural sac size is correlated with phenotypic characteristics seen in individuals with heritable connective tissue disorders. Methods: Two readers blinded to diagnosis measured anterior–posterior and transverse dural sac diameter using L1–L5 magnetic resonance images of 71 patients with idiopathic bronchiectasis, 72 control subjects without lung disease, 29 patients with cystic fibrosis, and 24 patients with Marfan syndrome. We compared groups by pairwise analysis of means, using Tukey’s method to adjust for multiple comparisons. Dural sac diameter association with phenotypic and clinical features was also tested. Measurements and Main Results: The L1–L5 (average) anterior–posterior dural sac diameter of the idiopathic bronchiectasis group was larger than those of the control group (P < 0.001) and the cystic fibrosis group (P = 0.002). There was a strong correlation between increased dural sac size and the presence of pulmonary nontuberculous mycobacterial infection (P = 0.007) and long fingers (P = 0.003). A trend toward larger dural sac diameter was seen in those with scoliosis (P = 0.130) and those with a family history of idiopathic bronchiectasis (P = 0.149). Conclusions: Individuals with idiopathic bronchiectasis have an enlarged dural sac diameter, which is associated with pulmonary nontuberculous mycobacterial infection, long fingers, and family history of idiopathic bronchiectasis. These findings support our

  4. 45. SAC conference room 2A8, second floor, Dwing, building 500, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    45. SAC conference room 2A8, second floor, D-wing, building 500, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE

  5. Behavioral and Brain Measures of Phasic Alerting Effects on Visual Attention.

    PubMed

    Wiegand, Iris; Petersen, Anders; Finke, Kathrin; Bundesen, Claus; Lansner, Jon; Habekost, Thomas

    2017-01-01

    In the present study, we investigated effects of phasic alerting on visual attention in a partial report task, in which half of the displays were preceded by an auditory warning cue. Based on the computational Theory of Visual Attention (TVA), we estimated parameters of spatial and non-spatial aspects of visual attention and measured event-related lateralizations (ERLs) over visual processing areas. We found that the TVA parameter sensory effectiveness a , which is thought to reflect visual processing capacity, significantly increased with phasic alerting. By contrast, the distribution of visual processing resources according to task relevance and spatial position, as quantified in parameters top-down control α and spatial bias w index , was not modulated by phasic alerting. On the electrophysiological level, the latencies of ERLs in response to the task displays were reduced following the warning cue. These results suggest that phasic alerting facilitates visual processing in a general, unselective manner and that this effect originates in early stages of visual information processing.

  6. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  7. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  8. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  9. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  10. 47 CFR 80.1111 - Distress alerting.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES STATIONS IN THE... Safety Communications § 80.1111 Distress alerting. (a) The transmission of a distress alert indicates... distress message format, which is relayed through space stations. (b) The distress alert must be sent...

  11. [Naringin reduced polymethylmethacrylate-induced osteolysis in the mouse air sacs model].

    PubMed

    Li, Nian-Hu; Xu, Zhan-wang

    2015-04-01

    To evaluate the influence of naringin on PMMA-induced osteoclastic bone resorption using the mouse air sacs model. Total 48 female Balb/c mices with the age of 8 to 10 weeks were chosen in the study. Air were injected into the back in 32 mices and formed the air sacs, 6 d later, the skulls (originated from other 16 mices) were implanted to the air sacs. Thirty-two animals were divided into naringin treatment group (with 2 concentrations of 150 mg/kg and 30 mg/ kg) , DMSO group and PBS blank group, 8 animals in each group. Polymethylmethacrylate (PMMA) particles were injected into the air sacs in naringin treatment groups and DMSO group so as to irritate inflammatory reaction. Naringin with 2 concentrations of 150 mg/kg and 30 mg/kg were dissolved in DMSO of 0.2 ml, and were injected into air sacs, respectively. In PBS black group, no stimulation with PMMA particles, only injected PBS, and in DMSO group, injected DMSO without naringin. Tartrate resistant acid phosphatase (TRAP), Ca2+ release, modified Masson stain and histological analysis were performed on the 7th day after stimulation. Compared with DMSO group, naringin treatment group's cellular infiltration decreased (P < 0.01); concentration of 150 mg/kg was better than that of concentrations of 30 mg/kg (8.90 ± 1.75 vs 15.23 ± 1.86). Naringin can decrease calcium release in the lavage of the air sacs bone resorption model, especially obvious in naringin with concentration of 150 mg/kg. Naringin can ameliorate the inflammatory reaction and the subsequent bone resorption (including bone collagen loss, TRAP positive cells amount and so on) in air sacs with bone implant and PMMA particles. Naringin with concentration of 150 mg/kg appeared to be an optimal dosage to deliver the therapeutic effects. Naringin inhibits PMMA-induced osteoclastogenesis and ameliorates the PMMA-associated inflammatory reaction and the subsequent bone resorption.

  12. Prescription order risk factors for pediatric dosing alerts.

    PubMed

    Stultz, J S; Porter, K; Nahata, M C

    2015-02-01

    To determine dosing alert rates based on prescription order characteristics and identify prescription order risk factors for the occurrence of dosing alerts. A retrospective analysis of inpatient medication orders and dosing alerts occurring during October 2011 and January, April, and July 2012 at a pediatric institution. Prescription orders and alerts were categorized by: medication class, patient age, route of administration, and month of the year. There were 228,259 orders during the studied period, with 11,072 alerted orders (4.9%). The most frequently alerted medication class was the non-analgesic central nervous system agent class (14% of alerts). Age, route, medication class, and month all independently affected dosing alert rates. The alert rate was highest for immunosuppressive agents (54%), neonates (6.7%), and orders for rectal administration (9.5%). The alert rate was higher in adult patients receiving their care at a pediatric institution (5.7%) compared to children (4.7%), but after multivariate analysis, pediatric orders had higher odds for an alert (OR 1.1, 95% CI 1.05-1.16). Mercaptopurine had the highest alert rate when categorized by active ingredient (73.9%). Albuterol 2.5mg/mL continuous aerosol and heparin 1000 units in 0.9% sodium chloride injection solution were the unique medications with the highest alert rates (100.0% and 97.7%, respectively). Certain types of prescription orders have a higher risk for causing dosing alerts than others. Patient age, medication class, route of administration, and the month of year can affect dosing alert rates. Design and customization efforts should focus on these medications and prescription order characteristics that increase the risk for dosing alerts. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  13. Global multi-sensor satellite monitoring of volcanic SO2 and ash emissions in support to aviation control

    NASA Astrophysics Data System (ADS)

    Brenot, H.; Theys, N.; van Gent, J.; Van Roozendael, M.; van der A, R.; Clarisse, L.; Hurtmans, D.; Ngadi, Y.; Coheur, P.-F.; Clerbaux, C.

    2012-04-01

    The "Support to Aviation Control Service" (SACS; http://sacs.aeronomie.be) is an ESA-funded project hosted by the Belgian Institute for Space Aeronomy. The service provides near real-time (NRT) global SO2 and volcanic ash data, as well as alerts in case of volcanic eruptions. The SACS service is primarily designed to support the Volcanic Ash Advisory Centers (VAACs) in their mandate to gather information on volcanic clouds and give advice to airline and air traffic control organisations. SACS also serves other users that subscribe to the service, in particular local volcano observatories and research scientists. SACS is based on the combined use of UV-visible (SCIAMACHY, OMI, GOME-2) and infrared (AIRS, IASI) satellite instruments. When a volcanic eruption is detected, SACS issues an alert that takes the form of a notification sent by e-mail to users. This notification points to a dedicated web page where all relevant information is available and can be visualized with user-friendly tools. The strength of a multi-sensor approach relies in the use of satellite data with different overpasses times, minimizing the time-lag for detection and enhancing the reliability of such alerts. This paper will give a general presentation of the SACS service, different techniques used to detect volcanic plumes. It will also highlight the strengths and limitations of the service and measurements.

  14. Predictive Information: Status or Alert Information?

    NASA Technical Reports Server (NTRS)

    Trujillo, Anna C.; Bruneau, Daniel; Press, Hayes N.

    2008-01-01

    Previous research investigating the efficacy of predictive information for detecting and diagnosing aircraft system failures found that subjects like to have predictive information concerning when a parameter would reach an alert range. This research focused on where the predictive information should be located, whether the information should be more closely associated with the parameter information or with the alert information. Each subject saw 3 forms of predictive information: (1) none, (2) a predictive alert message, and (3) predictive information on the status display. Generally, subjects performed better and preferred to have predictive information available although the difference between status and alert predictive information was minimal. Overall, for detection and recalling what happened, status predictive information is best; however for diagnosis, alert predictive information holds a slight edge.

  15. Deposition of anal-sac secretions by captive wolves (Canis lupus)

    USGS Publications Warehouse

    Asa, C.S.; Peterson, E.K.; Seal, U.S.; Mech, L.D.

    1985-01-01

    Deposition of anal-sac secretions by captive wolves was investigated by a labelling technique using protein-bound iodine125 and food dye. Wolves deposited secretions on some but not all scats. Adult males, especially the alpha male, deposited anal-sac secretions more frequently while defecating than did females or juveniles. Secretions sometimes also were deposited independently of defecation, suggesting a dual role in communication by these substances.

  16. Decision Support Alerts for Medication Ordering in a Computerized Provider Order Entry (CPOE) System

    PubMed Central

    Beccaro, M. A. Del; Villanueva, R.; Knudson, K. M.; Harvey, E. M.; Langle, J. M.; Paul, W.

    2010-01-01

    Objective We sought to determine the frequency and type of decision support alerts by location and ordering provider role during Computerized Provider Order Entry (CPOE) medication ordering. Using these data we adjusted the decision support tools to reduce the number of alerts. Design Retrospective analyses were performed of dose range checks (DRC), drug-drug interaction and drug-allergy alerts from our electronic medical record. During seven sampling periods (each two weeks long) between April 2006 and October 2008 all alerts in these categories were analyzed. Another audit was performed of all DRC alerts by ordering provider role from November 2008 through January 2009. Medication ordering error counts were obtained from a voluntary error reporting system. Measurement/Results Between April 2006 and October 2008 the percent of medication orders that triggered a dose range alert decreased from 23.9% to 7.4%. The relative risk (RR) for getting an alert was higher at the start of the interventions versus later (RR= 2.40, 95% CI 2.28-2.52; p< 0.0001). The percentage of medication orders that triggered alerts for drug-drug interactions also decreased from 13.5% to 4.8%. The RR for getting a drug interaction alert at the start was 1.63, 95% CI 1.60-1.66; p< 0.0001. Alerts decreased in all clinical areas without an increase in reported medication errors. Conclusion We reduced the quantity of decision support alerts in CPOE using a systematic approach without an increase in reported medication errors PMID:23616845

  17. Nordic rattle: the hoarse vocalization and the inflatable laryngeal air sac of reindeer (Rangifer tarandus)

    PubMed Central

    Frey, Roland; Gebler, Alban; Fritsch, Guido; Nygrén, Kaarlo; Weissengruber, Gerald E

    2007-01-01

    Laryngeal air sacs have evolved convergently in diverse mammalian lineages including insectivores, bats, rodents, pinnipeds, ungulates and primates, but their precise function has remained elusive. Among cervids, the vocal tract of reindeer has evolved an unpaired inflatable ventrorostral laryngeal air sac. This air sac is not present at birth but emerges during ontogenetic development. It protrudes from the laryngeal vestibulum via a short duct between the epiglottis and the thyroid cartilage. In the female the growth of the air sac stops at the age of 2–3 years, whereas in males it continues to grow up to the age of about 6 years, leading to a pronounced sexual dimorphism of the air sac. In adult females it is of moderate size (about 100 cm3), whereas in adult males it is large (3000–4000 cm3) and becomes asymmetric extending either to the left or to the right side of the neck. In both adult females and males the ventral air sac walls touch the integument. In the adult male the air sac is laterally covered by the mandibular portion of the sternocephalic muscle and the skin. Both sexes of reindeer have a double stylohyoid muscle and a thyroepiglottic muscle. Possibly these muscles assist in inflation of the air sac. Head-and-neck specimens were subjected to macroscopic anatomical dissection, computer tomographic analysis and skeletonization. In addition, isolated larynges were studied for comparison. Acoustic recordings were made during an autumn round-up of semi-domestic reindeer in Finland and in a small zoo herd. Male reindeer adopt a specific posture when emitting their serial hoarse rutting calls. Head and neck are kept low and the throat region is extended. In the ventral neck region, roughly corresponding to the position of the large air sac, there is a mane of longer hairs. Neck swelling and mane spreading during vocalization may act as an optical signal to other males and females. The air sac, as a side branch of the vocal tract, can be considered as

  18. Development and implementation of sepsis alert systems

    PubMed Central

    Harrison, Andrew M.; Gajic, Ognjen; Pickering, Brian W.; Herasevich, Vitaly

    2016-01-01

    Synopsis/Summary Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Important barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload & alert fatigue, due to suboptimal alert performance. Outside the ICU, additional barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Currently available evidence does not support routine use of sepsis alert systems in clinical practice. However, continuous improvement in both the afferent (data availability and accuracy of detection algorithms) and efferent (evidence-based decision support and smoother integration into clinical workflow) limbs of sepsis alert systems will help translate theoretical advantages into measurable patient benefit. PMID:27229639

  19. Wearable PPG sensor based alertness scoring system.

    PubMed

    Dey, Jishnu; Bhowmik, Tanmoy; Sahoo, Saswata; Tiwari, Vijay Narayan

    2017-07-01

    Quantifying mental alertness in today's world is important as it enables the person to adopt lifestyle changes for better work efficiency. Miniaturized sensors in wearable devices have facilitated detection/monitoring of mental alertness. Photoplethysmography (PPG) sensors through Heart Rate Variability (HRV) offer one such opportunity by providing information about one's daily alertness levels without requiring any manual interference from the user. In this paper, a smartwatch based alertness estimation system is proposed. Data collected from PPG sensor of smartwatch is processed and fed to machine learning based model to get a continuous alertness score. Utility functions are designed based on statistical analysis to give a quality score on different stages of alertness such as awake, long sleep and short duration power nap. An intelligent data collection approach is proposed in collaboration with the motion sensor in the smartwatch to reduce battery drainage. Overall, our proposed wearable based system provides a detailed analysis of alertness over a period in a systematic and optimized manner. We were able to achieve an accuracy of 80.1% for sleep/awake classification along with alertness score. This opens up the possibility for quantifying alertness levels using a single PPG sensor for better management of health related activities including sleep.

  20. ShakeAlert Users Transition to the Production Prototype System

    NASA Astrophysics Data System (ADS)

    Strauss, J. A.; Vinci, M.; Steele, W. P.; Hellweg, M.; Allen, R. M.; DeGroot, R. M.

    2016-12-01

    The ShakeAlert Earthquake Early Warning system transitioned from the demonstration system into the fully-fledged production prototype system this year. Users were migrated over to the new system concurrent with the release of the ShakeAlert UserDisplay Version 2.5.0. The production prototype system provides robust connectivity, fail-over mechanisms to ensure that alarms are deliverd even if one connection fails, and provides a framework to connect future stations, participants, and other sources as the project expands to the full public system. We will present an overview of key user sectors that are either testing or launching pilot projects for the system within their organizations. We will outline the implementation of certain actions, and highlight accomplishments and challenges the Beta Users encounter in fully implementing ShakeAlert within their organizations. By better studying these issues, project partners can better assist the users in incorporating early warning in their operations. Opening up the system to allow for pilot projects enables ShakeAlert users to develop hardware, software, and policy solutions for actions in response to early warning alerts in a controlled environment. This is the first step on the path toward limited rollouts. The pilot groups leverage the expertise of our stakeholders to develop the `last mile' alert distribution and responses. The transition went smoothly in February 2015, for users in California, and we expect to connect with more beta users and pilot groups in this next phase. User transition is planned for Fall 2016 for users in the Pacific Northwest. Beta Users, such as municipalities, emergency response groups, and county officials, lifelines, schools, and private industry continue to meet with ShakeAlert partners to 1) further education and training on both benefits and limitations 2) strategize on implementation actions, such as opening fire house bay doors in response to an alarm, and 3) coordinate continued

  1. An Isolated Venous Sac as a Novel Site for Cell Therapy in Diabetes Mellitus

    PubMed Central

    Kakabadze, Zurab; Shanava, Koba; Ricordi, Camillo; Shapiro, A.M. James; Gupta, Sanjeev; Berishvili, Ekaterine

    2013-01-01

    Background Transplanting pancreatic islets is of significant interest for type 1 diabetes mellitus. After intraportal injection of islets, inferior engraftment and eventual loss of transplanted islets constitute major limitations. Therefore, alternative approaches will be helpful. Here, we evaluated in animals whether an isolated venous sac would support survival of transplanted islets, along with correction of hyperglycemia. Methods Pancreatic islets isolated from adult Lewis rats were transplanted either into an isolated venous sac made from lumbar vein or into the portal vein of syngeneic rats. The integrity and vascular organization of the venous sac was determined by studies of the local microcirculation. The engraftment, survival, and function of transplanted islets were analyzed by histology, including endocrine function in situ and by glycemic control in rats with streptozotocin-induced diabetes. Results Transplanted islets showed normal morphology with insulin expression in isolated venous sac during the long term. Transplanted islets received blood supply from vasa vasorum and had access to drainage through venous tributaries in the venous sac. This resulted in restoration of euglycemia in diabetic rats. Removal of islet graft-bearing venous sac in diabetic rats led to recurrence of hyperglycemia. By contrast, euglycemia was not restored in rats treated by intraportal transplantation of islets. Conclusions We demonstrated that pancreatic islets successfully engrafted and functioned in the isolated venous sac with ability to restore euglycemia in diabetic rats. Therefore, the isolated venous sac offers a new site for transplantation of pancreatic islets. This would be clinically beneficial as an alternative to intrahepatic islet transplantation. PMID:22814331

  2. Proposed Education Guidelines and Procedures: Sac and Fox Nation of Oklahoma.

    ERIC Educational Resources Information Center

    Sac and Fox Nation, OK. Education Committee.

    These educational guidelines and procedures were developed after extensive review of current education programs for the Sac and Fox Nations of Oklahoma. The guidelines, prepared by a committee of local educators appointed by a tribal business committee, examined the anticipated needs for future generations of the Sac and Fox people. The document…

  3. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...

  4. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...

  5. 21 CFR 26.20 - Alert system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Alert system. 26.20 Section 26.20 Food and Drugs... Provisions for Pharmaceutical Good Manufacturing Practices § 26.20 Alert system. (a) The details of an alert...

  6. Monitoring alert and drowsy states by modeling EEG source nonstationarity

    NASA Astrophysics Data System (ADS)

    Hsu, Sheng-Hsiou; Jung, Tzyy-Ping

    2017-10-01

    Objective. As a human brain performs various cognitive functions within ever-changing environments, states of the brain characterized by recorded brain activities such as electroencephalogram (EEG) are inevitably nonstationary. The challenges of analyzing the nonstationary EEG signals include finding neurocognitive sources that underlie different brain states and using EEG data to quantitatively assess the state changes. Approach. This study hypothesizes that brain activities under different states, e.g. levels of alertness, can be modeled as distinct compositions of statistically independent sources using independent component analysis (ICA). This study presents a framework to quantitatively assess the EEG source nonstationarity and estimate levels of alertness. The framework was tested against EEG data collected from 10 subjects performing a sustained-attention task in a driving simulator. Main results. Empirical results illustrate that EEG signals under alert versus drowsy states, indexed by reaction speeds to driving challenges, can be characterized by distinct ICA models. By quantifying the goodness-of-fit of each ICA model to the EEG data using the model deviation index (MDI), we found that MDIs were significantly correlated with the reaction speeds (r  =  -0.390 with alertness models and r  =  0.449 with drowsiness models) and the opposite correlations indicated that the two models accounted for sources in the alert and drowsy states, respectively. Based on the observed source nonstationarity, this study also proposes an online framework using a subject-specific ICA model trained with an initial (alert) state to track the level of alertness. For classification of alert against drowsy states, the proposed online framework achieved an averaged area-under-curve of 0.745 and compared favorably with a classic power-based approach. Significance. This ICA-based framework provides a new way to study changes of brain states and can be applied to

  7. Finite Element Analysis of Stresses Developed in the Blood Sac of a Left Ventricular Assist Device

    PubMed Central

    Haut Donahue, T. L.; Dehlin, W.; Gillespie, J.; Weiss, W.J.; Rosenberg, G.

    2009-01-01

    The goal of this research is to develop a 3D finite element (FE) model of a left ventricular assist device (LVAD) to predict stresses in the blood sac. The hyperelastic stress-strain curves for the segmented poly(ether polyurethane urea) blood sac were determined in both tension and compression using a servo-hydraulic testing system at various strain rates. Over the range of strain rates studied, the sac was not strain rate sensitive, however the material response was different for tension versus compression. The experimental tension and compression properties were used in a FE model that consisted of the pusher plate, blood sac and pump case. A quasi-static analysis was used to allow for nonlinearities due to contact and material deformation. The 3D FE model showed that blood sac stresses are not adversely affected by the location of the inlet and outlet ports of the device and that over the systolic ejection phase of the simulation the prediction of blood sac stresses from the full 3D model and an axisymmetric model are the same. Minimizing stresses in the blood sac will increase the longevity of the blood sac in vivo. PMID:19131267

  8. Cells of the connective tissue differentiate and migrate into pollen sacs

    NASA Astrophysics Data System (ADS)

    Iqbal, M. C. M.; Wijesekara, Kolitha B.

    2002-01-01

    In angiosperms, archesporial cells in the anther primordium undergo meiosis to form haploid pollen, the sole occupants of anther sacs. Anther sacs are held together by a matrix of parenchyma cells, the connective tissue. Cells of the connective tissue are not known to differentiate. We report the differentiation of parenchyma cells in the connective tissue of two Gordonia species into pollen-like structures (described as pseudopollen), which migrate into the anther sacs before dehiscence. Pollen and pseudopollen were distinguishable by morphology and staining. Pollen were tricolpate to spherical while pseudopollen were less rigid and transparent with a ribbed surface. Both types were different in size, shape, staining and surface architecture. The ratio of the number of pseudopollen to pollen was 1:3. During ontogeny in the connective tissue, neither cell division nor tetrad formation was observed and hence pseudopollen were presumed to be diploid. Only normal pollen germinated on a germination medium. Fixed preparations in time seemed to indicate that pseudopollen migrate from the connective tissue into the anther sac.

  9. Evaluation of Helmet Mounted Display Alerting Symbology

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe; Rutkowski, Michael (Technical Monitor)

    2000-01-01

    Proposed helicopter helmet mounted displays will be used to alert the pilot to a variety of conditions, from threats to equipment problems. The present research was performed under the NASA Safe All-weather Flight Operations Research (SAFOR) program supported by a joint Army/NASA research agreement. The purpose of the research was to examine ways to optimize the alerting effectiveness of helmet display symbology. The research used two approaches to increasing the effectiveness of alerts. One was to increase the ability of the alert to attract attention by using the entire display surface. The other was to include information about the required response in the alert itself. The investigation was conducted using the NASA Ames Research Center's six-degree-of-freedom vertical motion simulator (VMS) with a rotorcraft cockpit. Helmet display symbology was based on the AH-64's pilot night vision system (PNVS), cruise mode symbology. A standardized mission was developed, that consisted of 11 legs. The mission included four tasks, which allowed variation in the frequency of alerts. The general trend in the data points to a small benefit from both the full-screen alert and the partial information alert.

  10. Medication-related clinical decision support alert overrides in inpatients.

    PubMed

    Nanji, Karen C; Seger, Diane L; Slight, Sarah P; Amato, Mary G; Beeler, Patrick E; Her, Qoua L; Dalleur, Olivia; Eguale, Tewodros; Wong, Adrian; Silvers, Elizabeth R; Swerdloff, Michael; Hussain, Salman T; Maniam, Nivethietha; Fiskio, Julie M; Dykes, Patricia C; Bates, David W

    2018-05-01

    To define the types and numbers of inpatient clinical decision support alerts, measure the frequency with which they are overridden, and describe providers' reasons for overriding them and the appropriateness of those reasons. We conducted a cross-sectional study of medication-related clinical decision support alerts over a 3-year period at a 793-bed tertiary-care teaching institution. We measured the rate of alert overrides, the rate of overrides by alert type, the reasons cited for overrides, and the appropriateness of those reasons. Overall, 73.3% of patient allergy, drug-drug interaction, and duplicate drug alerts were overridden, though the rate of overrides varied by alert type (P < .0001). About 60% of overrides were appropriate, and that proportion also varied by alert type (P < .0001). Few overrides of renal- (2.2%) or age-based (26.4%) medication substitutions were appropriate, while most duplicate drug (98%), patient allergy (96.5%), and formulary substitution (82.5%) alerts were appropriate. Despite warnings of potential significant harm, certain categories of alert overrides were inappropriate >75% of the time. The vast majority of duplicate drug, patient allergy, and formulary substitution alerts were appropriate, suggesting that these categories of alerts might be good targets for refinement to reduce alert fatigue. Almost three-quarters of alerts were overridden, and 40% of the overrides were not appropriate. Future research should optimize alert types and frequencies to increase their clinical relevance, reducing alert fatigue so that important alerts are not inappropriately overridden.

  11. Development and Implementation of Sepsis Alert Systems.

    PubMed

    Harrison, Andrew M; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2016-06-01

    Development and implementation of sepsis alert systems is challenging, particularly outside the monitored intensive care unit (ICU) setting. Barriers to wider use of sepsis alerts include evolving clinical definitions of sepsis, information overload, and alert fatigue, due to suboptimal alert performance. Outside the ICU, barriers include differences in health care delivery models, charting behaviors, and availability of electronic data. Current evidence does not support routine use of sepsis alert systems in clinical practice. Continuous improvement in the afferent and efferent aspects will help translate theoretic advantages into measurable patient benefit. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  13. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.300 Alert aggregator. [Reserved] ...

  14. Vascularization and VEGF expression altered in bovine yolk sacs from IVF and NT technologies.

    PubMed

    Mess, Andrea Maria; Carreira, Ana Claudia Oliveira; Marinovic de Oliveira, Cláudia; Fratini, Paula; Favaron, Phelipe Oliveira; Barreto, Rodrigo da Silva Nunes; Pfarrer, Christiane; Meirelles, Flávio Vieira; Miglino, Maria Angelica

    2017-01-01

    Reproductive technologies are widely used in cattle, although many are associated with high-embryonic mortality, especially during early gestation, when the yolk sac undergoes macroscopic changes in structure. We hypothesized that vasculogenesis and angiogenesis are affected, thereby affecting embryonic and placental differentiation. To test this, we studied yolk sac development and gene expression of the vascular endothelial growth factor system (VEGF-A, VEGFR-1/Flt-1, VEGFR-2/KDR). Samples from Days 25 to 40/41 of pregnancy from control cattle (n = 8) and from pregnancies established with IVF, (n = 7) or somatic cell nuclear transfer/clones (n = 5) were examined by histology, immunohistochemistry, and quantitative reverse transcriptase PCR. Yolk sacs in IVF- and nuclear transfer-derived pregnancies were immature. Development of villi was sparse in IVF yolk sacs, whereas vascularization was barely formed in clones and was associated, in part, with thin or interrupted endothelium. Transcript levels of the genes characterized exceed minimum detection limits for all groups, except in the mentioned clone with interrupted endothelium. Levels of mRNA for VEGF-A and VEGFR-2 were significantly higher in IVF yolk sacs. Clones had substantial individual variation in gene expression (both upregulation and downregulation). Our data confirmed the broad range in expression of VEGF genes. Furthermore, overexpression in IVF yolk sacs may compensate for an immature yolk sac structure, whereas in clones, patchy expression may cause structural alterations of blood vessels. In conclusion, we inferred that disturbances of yolk sac vasculature contributed to increased early embryonic mortality of bovine pregnancies established with reproductive technologies. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Physicians’ response to computerised alerts for psychotropic drugs in older persons: a multilevel analysis of the associated alert, patient and physician characteristics

    PubMed Central

    Tamblyn, Robyn; Reidel, Kristen; Patel, Vaishali

    2012-01-01

    Objective Computerised drug alerts are expected to reduce patients’ risk of adverse drug events. However, physicians over-ride most drug alerts, because they believe that the benefit exceeds the risk. The purpose of this study was to determine the drug alert, patient and physician characteristics associated with the: (1) occurrence of psychotropic drug alerts for elderly patients and the (2) response to these alerts by their primary care physicians. Setting Primary care, Quebec, Canada. Design Prospective cohort study. Participants Sixty-one physicians using an electronic prescribing and drug alert decision-support system in their practice, and 3413 elderly patients using psychotropic drugs. Primary and secondary measures Psychotropic drug class, alert severity, patient risk for fall injuries and physician experience, practice volume and computer use were evaluated in relationship to the likelihood of having: (1) a psychotropic drug alert, (2) the prescription revised in response to an alert. Cluster-adjusted alternating logistic regression was used to assess multilevel predictors of alert occurrence and response. Results In total 13 080 psychotropic drug alerts were generated in 8931 visits. Alerts were more likely to be generated for male patients at higher risk of fall-related injury and for physicians who established the highest alert threshold. In 9.9% of alerts seen, the prescription was revised. The highest revision rate was for antipsychotic alerts (22.6%). Physicians were more likely to revise prescriptions for severe alerts (OR 2.03; 95%CI 1.39 to 2.98), if patients had cognitive impairment (OR 1.95; 95%CI 1.13 to 3.36), and if they made more visits to their physician (OR 1.05 per 5 visits; 95%CI 1 to 1.09). Conclusions Physicians view and respond to a small proportion of alerts, mainly for higher-risk patients. To reduce the risk of psychotropic drug-related fall injuries, a new generation of evidence-based drug alerts should be developed. PMID

  16. 75 FR 67201 - Flightcrew Alerting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-02

    ... airplanes concerning flightcrew alerting. These standards update definitions, prioritization, color... addressed regulations regarding definitions, prioritization, color requirements, and performance for... proposal: Reserving and limiting the use of alerting colors red, amber, or yellow on the flight deck...

  17. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  18. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  19. 47 CFR 10.300 - Alert aggregator. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Alert aggregator. [Reserved] 10.300 Section 10.300 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.300 Alert aggregator. [Reserved] ...

  20. The effect of pigeon yolk sac fluid on the growth behavior of calcium carbonate crystals.

    PubMed

    Song, Juan; Cheng, Haixia; Shen, Xinyu; Tong, Hua

    2015-03-01

    Previous experiments have proved that thermodynamically unstable calcium carbonate vaterite can exist for long periods in the yolk sac of a pigeon embryo. The aim of this article was to demonstrate the effect of in vitro mineralization of yolk sac fluid on calcium carbonate by direct precipitation. Experiments were conducted using pigeon yolk sac fluid and using lecithin extracted from pigeon yolk sac fluid as a control to investigate the regulating effects of the organic components in the embryo on the formation of the calcium carbonate precipitate. Multiple characterization methods were employed to study the various morphological patterns, sizes, crystal growth, and crystal phase transformations of the calcium carbonate precipitates as regulated by the yolk sac fluid extracted at different stages of incubation. The experimental results demonstrate that as the incubation proceeds towards the later stages, the composition and environmental features of the yolk sac fluid become more favorable for the formation of relatively unstable calcium carbonate phases with high energies of the vaterite state. The experiments conducted with extracted lecithin as the template for crystal growth yielded similar results. A large amount of organic molecules with polar functional groups carried by the yolk sac fluid have strong effects and can both initially induce the crystallization and regulate the aggregation of calcium carbonate. Furthermore, this regulation process is found to be closely related to the lecithin contained in yolk sac fluid. These observations confirm the changes in yolk sac fluid composition during incubation have significant effects on the production of vaterite, which implicates the calcium transport during embryo growth. © 2015 Poultry Science Association Inc.

  1. Aquarius/SAC-D Observatory before Departing Brazil

    NASA Image and Video Library

    2011-04-19

    After months of environmental tests at Brazil National Institute for Space Research Instituto Nacional de Pesquisas Espaciais, INPE, NASA Aquarius/SAC-D observatory is loaded into a crate for shipment to Vandenberg Air Force Base.

  2. Innate immune defense in the inner ear - mucines are expressed by the human endolymphatic sac.

    PubMed

    Møller, Martin N; Kirkeby, Svend; Cayé-Thomasen, Per

    2017-02-01

    The human endolymphatic sac has been shown recently to have immunological capacities and has thus been proposed as the main entity protecting the inner ear from pathogen invasion, equivalent to mucosa-associated lymphoid tissue (MALT). Although the sac expresses molecules of the innate immune system, the potential expression of members of the important mucin family has not been detailed. Thus, this paper explores endolymphatic sac expression of a number of mucins and mucin precursors. Twelve fresh tissue samples from the human endolymphatic sac were obtained during translabyrinthine surgery. The expression of Mucin 1, 2, 5B/AC and 16, as well as the core structure elements (mucin precursors) T-antigen, Tn-antigen and Sialyl-Tn-antigen was investigated by immunohistochemistry. The endolymphatic sac epithelium expressed MUC1 (both apically towards the endolymphatic sac (ES) lumen and basally towards the capillary network), MUC 16 and Tn-antigen. There was no labeling after incubation with antibodies against T-antigen, sialyl-Tn-antigen, MUC2 and MUC5B/AC. We conclude that the human endolymphatic sac epithelium expresses a number of mucin molecules, which supports the hypothesis of the sac as the primary immunological tissue structure of the inner ear, equivalent to MALT in other organs. The mucins may also play a role in the formation and continuous homeostasis of the inner ear fluids, as well as the pathogenesis of Meniere's disease. © 2016 Anatomical Society.

  3. Involvement of Sac1 phosphoinositide phosphatase in the metabolism of phosphatidylserine in the yeast Saccharomyces cerevisiae.

    PubMed

    Tani, Motohiro; Kuge, Osamu

    2014-04-01

    Sac1 is a phosphoinositide phosphatase that preferentially dephosphorylates phosphatidylinositol 4-phosphate. Mutation of SAC1 causes not only the accumulation of phosphoinositides but also reduction of the phosphatidylserine (PS) level in the yeast Saccharomyces cerevisiae. In this study, we characterized the mechanism underlying the PS reduction in SAC1-deleted cells. Incorporation of (32) P into PS was significantly delayed in sac1∆ cells. Such a delay was also observed in SAC1- and PS decarboxylase gene-deleted cells, suggesting that the reduction in the PS level is caused by a reduction in the rate of biosynthesis of PS. A reduction in the PS level was also observed with repression of STT4 encoding phosphatidylinositol 4-kinase or deletion of VPS34 encoding phophatidylinositol 3-kinase. However, the combination of mutations of SAC1 and STT4 or VPS34 did not restore the reduced PS level, suggesting that both the synthesis and degradation of phosphoinositides are important for maintenance of the PS level. Finally, we observed an abnormal PS distribution in sac1∆ cells when a specific probe for PS was expressed. Collectively, these results suggested that Sac1 is involved in the maintenance of a normal rate of biosynthesis and distribution of PS. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Validation of the CME Geomagnetic Forecast Alerts Under the COMESEP Alert System

    NASA Astrophysics Data System (ADS)

    Dumbović, Mateja; Srivastava, Nandita; Rao, Yamini K.; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano

    2017-08-01

    Under the European Union 7th Framework Programme (EU FP7) project Coronal Mass Ejections and Solar Energetic Particles (COMESEP, http://comesep.aeronomy.be), an automated space weather alert system has been developed to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. The COMESEP alert system uses the automated detection tool called Computer Aided CME Tracking (CACTus) to detect potentially threatening CMEs, a drag-based model (DBM) to predict their arrival, and a CME geoeffectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, the DBM calculates its arrival time at Earth and the CGFT calculates its geomagnetic risk level. The geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geoeffectiveness, as well as an estimate of the geomagnetic storm duration. We present the evaluation of the CME risk level forecast with the COMESEP alert system based on a study of geoeffective CMEs observed during 2014. The validation of the forecast tool is made by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of the DBM and CGFT (independent tools available at the Hvar Observatory website, http://oh.geof.unizg.hr). The results indicate that the success rate of the forecast in its current form is unacceptably low for a realistic operation system. Human intervention improves the forecast, but the false-alarm rate remains unacceptably high. We discuss these results and their implications for possible improvement of the COMESEP alert system.

  5. Water quality in the Little Sac River basin near Springfield, Missouri, 1999-2001

    USGS Publications Warehouse

    Smith, Brenda J.

    2002-01-01

    had a bacteria density larger than the density in the effluent. Other sources of bacteria are likely to be present in the study area in addition to the NW WTP. These potential sources include effluent from domestic septic systems and animal wastes.Nutrient concentrations in the Little Sac River immediately downstream from the NW WTP were affected by effluent from the NW WTP and possibly other sources. At two sites upstream from the NW WTP, median nitrite plus nitrate concentrations were 1.1 and 1.4 milligrams per liter. The median nitrite plus nitrate concentration for the effluent from the NW WTP was 6.4 milligrams per liter, and the median concentration decreased downstream in the Little Sac River to 2.2, 1.2, and 0.56 milligrams per liter.The effects of the effluent from the NW WTP on the water quality of the Little Sac River downstream from the NW WTP were reflected in an increase in discharge (effluent from the NW WTP can be as much as 50 percent of the flow at the site about 1.5 river miles downstream from the NW WTP), an increase in specific conductance values, an increase in several inorganic constituent concentrations, including calcium, magnesium, and sulfate, and a large increase in sodium and chloride concentrations. The effluent from the NW WTP seemed to have no effect on the pH value, temperature, and dissolved oxygen concentrations in the Little Sac River.Results of repetitive element polymerase chain reaction (rep-PCR) pattern analysis indicated that most Escherichia coli (E. coli) bacteria in water samples probably were from nonhuman sources, such as horses and cattle. The rep-PCR pattern analysis indicated that horses were an important source of E. coli downstream from the NW WTP, which was consistent with horses pastured adjacent to the sampling site. Fecal coliform bacteria loads increased upstream from the NW WTP from the most upstream site to the site immediately upstream from the NW WTP. Loads in the effluent from the NW WTP and also tho

  6. Tolerance of the archaeal Sac7d scaffold protein to alternative library designs: characterization of anti-immunoglobulin G Affitins.

    PubMed

    Béhar, Ghislaine; Bellinzoni, Marco; Maillasson, Mike; Paillard-Laurance, Lauranne; Alzari, Pedro M; He, Xuemei; Mouratou, Barbara; Pecorari, Frédéric

    2013-04-01

    Engineered protein scaffolds have received considerable attention as alternatives to antibodies in both basic and applied research, as they can offer superior biophysical properties often associated with a simpler molecular organization. Sac7d has been demonstrated as an effective scaffold for molecular recognition. Here, we used the initial L1 'flat surface' library constructed by randomization of 14 residues, to identify ligands specific for human immunoglobulin G. To challenge the plasticity of the Sac7d protein scaffold, we designed the alternative L2 'flat surface & loops' library whereof only 10 residues are randomized. Representative binders (Affitins) of the two libraries exhibited affinities in the low nanomolar range and were able to recognize different epitopes within human immunoglobulin G. These Affitins were stable up to pH 12 while largely conserving other favorable properties of Sac7d protein, such as high expression yields in Escherichia coli, solubility, thermal stability up to 80.7°C, and acidic stability (pH 0). In agreement with our library designs, mutagenesis study revealed two distinct binding areas, one including loops. Together, our results indicate that the Sac7d scaffold tolerates alternative library designs, which further expands the diversity of Affitins and may provide a general way to create tailored affinity tools for demanding applications.

  7. Development of the endolymphatic sac in chick embryos, with reference to the degradation of otoconia

    NASA Technical Reports Server (NTRS)

    Yoshihara, T.; Kaname, H.; Narita, N.; Ishii, T.; Igarashi, M.; Fermin, C. D.

    1992-01-01

    The endolymphatic sac of chick embryos (from embryonic day 7 to 1-day-old chicks) was studied light- and electron-microscopically. At stage 30-31 (embryonic day 7-7.5), the epithelial cells of the endolymphatic sac were cuboidal to columnar in shape. Microvilli were relatively well developed. The intercellular space was wide. In the endolymphatic space of the endolymphatic sac, varying shapes and sizes of otoconia-like bodies were often observed. Intracytoplasmic phagosomes containing these bodies were rarely found. After stage 37 (embryonic day 11), otoconia-like bodies in the endolymphatic sac decreased in number and size. They were almost the same as the otoconia in the macular organs, ultrastructurally. These findings indicate that the endolymphatic sac of the chick embryos may possess the function of otoconial degradation and removal of calcium from otoconia.

  8. CISN ShakeAlert: Using early warnings for earthquakes in California

    NASA Astrophysics Data System (ADS)

    Vinci, M.; Hellweg, M.; Jones, L. M.; Khainovski, O.; Schwartz, K.; Lehrer, D.; Allen, R. M.; Neuhauser, D. S.

    2009-12-01

    Educated users who have developed response plans and procedures are just as important for an earthquake early warning (EEW) system as are the algorithms and computers that process the data and produce the warnings. In Japan, for example, the implementation of the EEW system which now provides advanced alerts of ground shaking included intense outreach efforts to both institutional and individual recipients. Alerts are now used in automatic control systems that stop trains, place sensitive equipment in safe mode and isolate hazards while the public takes cover. In California, the California Integrated Seismic Network (CISN) is now developing and implementing components of a prototype system for EEW, ShakeAlert. As this processing system is developed, we invite a suite of perspective users from critical industries and institutions throughout California to partner with us in developing useful ShakeAlert products and procedures. At the same time, we will support their efforts to determine and implement appropriate responses to an early warning of earthquake shaking. As a first step, in a collaboration with BART, we have developed a basic system allowing BART’s operation center to receive realtime ground shaking information from more than 150 seismic stations operating in the San Francisco Bay Area. BART engineers are implementing a display system for this information. Later phases will include the development of improved response procedures utilizing this information. We plan to continue this collaboration to include more sophisticated information from the prototype CISN ShakeAlert system.

  9. Alertness and cognitive control: Toward a spatial grouping hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    A puzzling interaction involving alertness and cognitive control is indicated by the finding of faster performance but larger congruency effects on alert trials (on which alerting cues are presented before the task stimuli) than on no-alert trials in selective attention tasks. In the present study, the author conducted four experiments to test hypotheses about the interaction. Manipulation of stimulus spacing revealed a difference in congruency effects between alert and no-alert trials for narrowly spaced stimuli but not for widely spaced stimuli, inconsistent with the hypothesis that increased alertness is associated with more diffuse attention. Manipulation of color grouping revealed similar differences in congruency effects between alert and no-alert trials for same-color and different-color groupings of targets and distractors, inconsistent with the general hypothesis that increased alertness is associated with more perceptual grouping. To explain the results, the author proposes that increased alertness is associated specifically with more spatial grouping of stimuli, possibly by modulating the threshold for parsing stimulus displays into distinct objects.

  10. 77 FR 41331 - Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... with the Commission's Commercial Mobile Alert System (CMS), Second Report and Order (``CMAS Second... Alert System rules contained in the Commission's Second Report and Order, FCC 08- 164, published at 73...

  11. Ground water in the Cul-de-Sac Plain, Haiti

    USGS Publications Warehouse

    Taylor, George C.; Lemoine, Rémy C.

    1949-01-01

    The Cul-de-Sac Plain is perhaps the most important agricultural area in Haiti because of its nearness and accessibility to Port-au-Prince, the nation's capital, metropolis, and principal seaport. Most of the agricultural produce consumed in Port-au-Prince as well as a considerable part of that exported from Haiti is grown in the plain.Because of variable and poorly distributed rainfall, high temperature, and high evaporation, semiarid climatic conditions prevail in the plain. Irrigation is, therefore, necessary for successful farming. There are no regulatory or storage facilities on the streams that enter the plain, but the mean and low-water stream flow and the discharge of springs are almost entirely appropriated for irrigation. Ground water has been utilized for irrigation to an increasing extent by the Haitian American Sugar Company, which has put down about 100 wells in the plain since 1919.Outside the existing irrigated areas of the plain are large tracts of potentially irrigable land that are uncultivated and agriculturally unproductive for lack of water. The object of the present study was to determine the possibilities of bringing these lands into cultivation by irrigation from wells. This study was part of a larger program of the Food Supply Division, Institute of Inter-American Affairs, to increase the production of food in Haiti.From September through November 1948 the senior author, a member of the U. S. Geological Survey, spent three months in the field in an investigation of the geology and ground-water resources of the Cul-de-Sac Plain. He was ably assisted by Mr. Rémy C. Lemoine, Haitian engineer-geologist, employed by the Food Supply Division. The field work included principally the geologic mapping of' the plain and the adjacent mountain borders, a ground-water inventory of existing wells and springs, and a general evaluation of significant geologic and hydrologic features.

  12. Seismic Analysis Code (SAC): Development, porting, and maintenance within a legacy code base

    NASA Astrophysics Data System (ADS)

    Savage, B.; Snoke, J. A.

    2017-12-01

    The Seismic Analysis Code (SAC) is the result of toil of many developers over almost a 40-year history. Initially a Fortran-based code, it has undergone major transitions in underlying bit size from 16 to 32, in the 1980s, and 32 to 64 in 2009; as well as a change in language from Fortran to C in the late 1990s. Maintenance of SAC, the program and its associated libraries, have tracked changes in hardware and operating systems including the advent of Linux in the early 1990, the emergence and demise of Sun/Solaris, variants of OSX processors (PowerPC and x86), and Windows (Cygwin). Traces of these systems are still visible in source code and associated comments. A major concern while improving and maintaining a routinely used, legacy code is a fear of introducing bugs or inadvertently removing favorite features of long-time users. Prior to 2004, SAC was maintained and distributed by LLNL (Lawrence Livermore National Lab). In that year, the license was transferred from LLNL to IRIS (Incorporated Research Institutions for Seismology), but the license is not open source. However, there have been thousands of downloads a year of the package, either source code or binaries for specific system. Starting in 2004, the co-authors have maintained the SAC package for IRIS. In our updates, we fixed bugs, incorporated newly introduced seismic analysis procedures (such as EVALRESP), added new, accessible features (plotting and parsing), and improved the documentation (now in HTML and PDF formats). Moreover, we have added modern software engineering practices to the development of SAC including use of recent source control systems, high-level tests, and scripted, virtualized environments for rapid testing and building. Finally, a "sac-help" listserv (administered by IRIS) was setup for SAC-related issues and is the primary avenue for users seeking advice and reporting bugs. Attempts are always made to respond to issues and bugs in a timely fashion. For the past thirty-plus years

  13. Termination of pregnancy at very early gestation without visible yolk sac on ultrasound.

    PubMed

    Heller, Rebecca; Cameron, Sharon

    2015-04-01

    Requests for termination of pregnancy (TOP) at very early gestation (≤6 weeks) can prove challenging for abortion services as the ultrasound feature usually accepted as definitive evidence of an intrauterine pregnancy (IUP), the presence of a yolk sac within a gestational sac, may not yet be evident. In 2011 the Edinburgh TOP service introduced a protocol permitting women to proceed to treatment without further investigations provided that ultrasound showed the features of an eccentrically placed gestational sac (≥3 mm) with a decidual reaction, and there were no signs, symptoms or risk factors for ectopic pregnancy. A retrospective audit was conducted of outcomes of women presenting for TOP at ≤6 weeks' gestation over a 2-year period using the hospital computerised database. A total of 1155 women presented for TOP with an ultrasound gestational age of ≤6 weeks. Of these, 1030 (89%) had ultrasound evidence of a yolk sac. Eighty-seven women (7.5%) had an eccentrically placed gestational sac with a decidual reaction. All 87 women fulfilled our criteria to proceed to medical TOP, and 66 did so. In the remaining 21 cases, further investigations were performed before they proceeded to medical TOP. Two (0.17%) medical TOPs failed, both in women whose initial ultrasound had shown a yolk sac. Women with ultrasound features consistent with a very early IUP (≥3 mm eccentrically placed gestational sac with a decidual reaction) and without signs, symptoms or risk factors for ectopic pregnancy can proceed directly to medical TOP without the need for delay for further ultrasonography. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  14. Sac ligation in inguinal hernia repair: A meta-analysis of randomized controlled trials.

    PubMed

    Kao, Chun-Yu; Li, Ching-Li; Lin, Chao-Chun; Su, Chih-Ming; Chen, Chia-Che; Tam, Ka-Wai

    2015-07-01

    Traditionally, hernia sac ligation during inguinal hernia repair is considered mandatory to prevent postoperative development of hernia. However, ligation may induce postoperative pain. The aim of this study was to evaluate the outcomes of hernia sac ligation after inguinal hernia repair. We conducted a systematic review and meta-analysis of randomized controlled trials to investigate the outcomes of hernia sac ligation for open or laparoscopic inguinal hernia repair. Incidence of hernia recurrence was assessed following the surgery. The secondary outcomes included pain scores and postoperative complications. Five trials were selected and their results were summarized. These 5 trials were published between 1984 and 2014, and the sample sizes ranged from 50 to 467 patients. Four trials had recruited patients with inguinal hernia who underwent open repair, and one study enrolled patients who underwent laparoscopic procedures. We observed no difference in the incidence of hernia recurrence and postoperative complications between the sac ligation and nonligation groups. Postoperatively, the intensity of pain was significantly higher in the ligation group than in the nonligation group at Day 7 (Weight mean difference 1.46; 95% confident interval: 0.98-1.95). Hernia sac ligation was associated with higher postoperative pain, and did not show any benefit over sac nonligation regarding the incidence of recurrence and postoperative complications in patients undergoing open tension-free mesh repair or laparoscopic procedures. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  15. Managing the Alert Process at NewYork-Presbyterian Hospital

    PubMed Central

    Kuperman, Gilad J; Diamente, Rosanna; Khatu, Vrinda; Chan-Kraushar, Terri; Stetson, Pete; Boyer, Aurelia; Cooper, Mary

    2005-01-01

    Clinical decision support can improve the quality of care, but requires substantial knowledge management activities. At NewYork-Presbyterian Hospital in New York City, we have implemented a formal alert management process whereby only hospital committees and departments can request alerts. An explicit requestor, who will help resolve the details of the alert logic and the alert message must be identified. Alerts must be requested in writing using a structured alert request form. Alert requests are reviewed by the Alert Committee and then forwarded to the Information Systems department for a software development estimate. The model required that clinical committees and departments become more actively involved in the development of alerts than had previously been necessary. In the 12 months following implementation, 10 alert requests were received. The model has been well received. A lot of the knowledge engineering work has been distributed and burden has been removed from scarce medical informatics resources. PMID:16779073

  16. Direct Effects of Microalgae and Protists on Herring (Clupea harengus) Yolk Sac Larvae

    PubMed Central

    Illing, Björn; Moyano, Marta; Niemax, Jan; Peck, Myron A.

    2015-01-01

    This study investigated effects of microalgae (Rhodomonas baltica) and heterotrophic protists (Oxyrrhis marina) on the daily growth, activity, condition and feeding success of Atlantic herring (Clupea harengus) larvae from hatch, through the end of the endogenous (yolk sac) period. Yolk sac larvae were reared in the presence and absence of microplankton and, each day, groups of larvae were provided access to copepods. Larvae reared with microalgae and protists exhibited precocious (2 days earlier) and ≥ 60% increased feeding incidence on copepods compared to larvae reared in only seawater (SW). In the absence and presence of microalgae and protists, life span and growth trajectories of yolk sac larvae were similar and digestive enzyme activity (trypsin) and nutritional condition (RNA-DNA ratio) markedly declined in all larvae directly after yolk sac depletion. Thus, microplankton promoted early feeding but was not sufficient to alter life span and growth during the yolk sac phase. Given the importance of early feeding, field programs should place greater emphasis on the protozooplankton-ichthyoplankton link to better understand match-mismatch dynamics and bottom-up drivers of year class success in marine fish. PMID:26035592

  17. Direct Effects of Microalgae and Protists on Herring (Clupea harengus) Yolk Sac Larvae.

    PubMed

    Illing, Björn; Moyano, Marta; Niemax, Jan; Peck, Myron A

    2015-01-01

    This study investigated effects of microalgae (Rhodomonas baltica) and heterotrophic protists (Oxyrrhis marina) on the daily growth, activity, condition and feeding success of Atlantic herring (Clupea harengus) larvae from hatch, through the end of the endogenous (yolk sac) period. Yolk sac larvae were reared in the presence and absence of microplankton and, each day, groups of larvae were provided access to copepods. Larvae reared with microalgae and protists exhibited precocious (2 days earlier) and ≥ 60% increased feeding incidence on copepods compared to larvae reared in only seawater (SW). In the absence and presence of microalgae and protists, life span and growth trajectories of yolk sac larvae were similar and digestive enzyme activity (trypsin) and nutritional condition (RNA-DNA ratio) markedly declined in all larvae directly after yolk sac depletion. Thus, microplankton promoted early feeding but was not sufficient to alter life span and growth during the yolk sac phase. Given the importance of early feeding, field programs should place greater emphasis on the protozooplankton-ichthyoplankton link to better understand match-mismatch dynamics and bottom-up drivers of year class success in marine fish.

  18. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 8 2014-01-01 2014-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. ...

  19. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 8 2013-01-01 2013-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. ...

  20. Conditional outlier detection for clinical alerting.

    PubMed

    Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F

    2010-11-13

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates.

  1. Archaeological Survey and Site Testing in Sloughing Easement Areas along the Sac River Downstream from Stockton Dam, Missouri.

    DTIC Science & Technology

    1986-01-01

    Inventories from Sites Outside of the Easement 288 28. Summary of Artifact Frequencies by Functional Category 290 29. Proportions of General Tool...farming community to that of a resort town, with its week-end and holiday crowds of skiers , fishermen, and sightseers. Also but on a more permanent...the Sac River drainage and adjacent drainages has identified a number of specific problems and gaps In our knowledge of the prehistory of the region

  2. 12 CFR 1022.121 - Active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 8 2012-01-01 2012-01-01 false Active duty alerts. 1022.121 Section 1022.121... Consumer Reporting Agencies Regarding Identity Theft § 1022.121 Active duty alerts. (a) Duration. The duration of an active duty alert shall be twelve months. (b) [Reserved] ...

  3. The Seismic Alert System of Mexico (SASMEX): Performance and Evolution

    NASA Astrophysics Data System (ADS)

    Espinosa Aranda, J.

    2013-05-01

    Cities, trough VHF and UHF radio signals, Fiber Optics, and Satellite technologies, to reach more reliability and availability SASMEX functions and services. To increase the seismic early warning efficiency the Mexico City Historical Center Authorities, promoted the installation of the NOAA VHF radio transmitters system to cover the Mexico City valley, operating with the Specific Area Message Encoding (SAME) called NWR-SAME, and with the Emergency Alert Systems (EAS) protocol of United States. As an enhancement of the NOAA receiver protocol, it was innovated to permit fast Public Alert issue, in no more than 2 sec. The new receiver applied in Mexico is called SARMEX™. Local and federal authorities acquired 90,000 SARMEX™ receivers to be distributed manly in public schools of Mexican cities covered by the SASMEX™ signals; the measure with the aim to promote better natural hazard prevention attitude in the Mexican young population segment.

  4. 48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...

  5. 48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...

  6. 48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...

  7. 48 CFR 301.603-72 - FAC-C and HHS SAC certification requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false FAC-C and HHS SAC... Responsibilities 301.603-72 FAC-C and HHS SAC certification requirements. (a) The FAC-C certification program is... thereunder are not required to re-take training courses, but shall follow FAC-C training requirements when...

  8. Hypercalcemia associated with an adenocarcinoma derived from the apocrine glands of the anal sac.

    PubMed

    Meuten, D J; Cooper, B J; Capen, C C; Chew, D J; Kociba, G J

    1981-07-01

    Clinical, gross, and light microscopic findings are described for 36 dogs, 33 females and three males, with adenocarcinomas arising from the apocrine glands of the anal sac. All tumors had light microscopic features of malignancy and 22 of 23 metastasized to iliac and lumbar lymph nodes. Nine dogs had disseminated metastases, but bone metastases were found in only one dog. Differentiated neoplasms formed secretory acini and tubules lined by tall columnar or cuboidal epithelium. Most neoplasms were histologically bimorphic, with glandular areas and solid nests. Parathyroid glands were atrophic. Hypercalcemia (mean = 16.1 mg/dl) was present in 20 of 22 dogs (90%) and hypophosphatemia (mean = 3.2 mg/dl) in 12 of 17 (71%). Remission of hypercalcemia by tumor ablation and recurrence of hypercalcemia with tumor regrowth suggested that the tumor produced a substance that caused hypercalcemia. This unique clinicopathologic syndrome is characterized by hypercalcemia in old, predominantly female, dogs with an adenocarcinoma arising from the apocrine glands of the anal sac.

  9. The effect of phasic auditory alerting on visual perception.

    PubMed

    Petersen, Anders; Petersen, Annemarie Hilkjær; Bundesen, Claus; Vangkilde, Signe; Habekost, Thomas

    2017-08-01

    Phasic alertness refers to a short-lived change in the preparatory state of the cognitive system following an alerting signal. In the present study, we examined the effect of phasic auditory alerting on distinct perceptual processes, unconfounded by motor components. We combined an alerting/no-alerting design with a pure accuracy-based single-letter recognition task. Computational modeling based on Bundesen's Theory of Visual Attention was used to examine the effect of phasic alertness on visual processing speed and threshold of conscious perception. Results show that phasic auditory alertness affects visual perception by increasing the visual processing speed and lowering the threshold of conscious perception (Experiment 1). By manipulating the intensity of the alerting cue, we further observed a positive relationship between alerting intensity and processing speed, which was not seen for the threshold of conscious perception (Experiment 2). This was replicated in a third experiment, in which pupil size was measured as a physiological marker of alertness. Results revealed that the increase in processing speed was accompanied by an increase in pupil size, substantiating the link between alertness and processing speed (Experiment 3). The implications of these results are discussed in relation to a newly developed mathematical model of the relationship between levels of alertness and the speed with which humans process visual information. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Alert Workplace From Healthcare Workers' Perspective: Behavioral and Environmental Strategies to Improve Vigilance and Alertness in Healthcare Settings.

    PubMed

    Sagah Zadeh, Rana; Shepley, Mardelle; Sadatsafavi, Hessam; Owora, Arthur Hamie; Krieger, Ana C

    2018-04-01

    This study aims to identify the behavioral and environmental strategies that healthcare workers view as helpful for managing sleepiness, improving alertness, and therefore optimizing workplace safety. Reduced alertness is a common issue in healthcare work environments and is associated with impaired cognitive performance and decision-making ability as well as increased errors and injuries. We surveyed 136 healthcare professionals at a primary care clinic, an acute care hospital, and a mental health clinic. Nonstructured, semistructured, and structured questionnaires were used to elicit relevant information which was analyzed using qualitative content analysis and logistic regression models, respectively. In order by frequency of endorsement: dietary intervention; physical mobility; cognitive, sensory, or social stimulation; personal lifestyle strategies; and rest/nap opportunities were reported as behavioral strategies used to address workplace alertness. Compared to other environmental features, daylight and thermal comfort were perceived to be more important to addressing workplace alertness ( p < .05). By optimizing the physical environment and organizational policies and providing education programs, we have an opportunity to support healthcare professionals in managing sleepiness and maintaining alertness at work. In addition, such system level interventions may reduce unhealthy choices such as frequent caffeine intake to keep alert. The development of multidisciplinary evidence-based guidelines is needed to address sleepiness and alertness to improve workplace safety in healthcare facilities.

  11. Conditional Outlier Detection for Clinical Alerting

    PubMed Central

    Hauskrecht, Milos; Valko, Michal; Batal, Iyad; Clermont, Gilles; Visweswaran, Shyam; Cooper, Gregory F.

    2010-01-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management actions using past patient cases stored in an electronic health record (EHR) system. Our hypothesis is that patient-management actions that are unusual with respect to past patients may be due to a potential error and that it is worthwhile to raise an alert if such a condition is encountered. We evaluate this hypothesis using data obtained from the electronic health records of 4,486 post-cardiac surgical patients. We base the evaluation on the opinions of a panel of experts. The results support that anomaly-based alerting can have reasonably low false alert rates and that stronger anomalies are correlated with higher alert rates. PMID:21346986

  12. Validation of the CME Geomagnetic forecast alerts under COMESEP alert system

    NASA Astrophysics Data System (ADS)

    Dumbovic, Mateja; Srivastava, Nandita; Khodia, Yamini; Vršnak, Bojan; Devos, Andy; Rodriguez, Luciano

    2017-04-01

    An automated space weather alert system has been developed under the EU FP7 project COMESEP (COronal Mass Ejections and Solar Energetic Particles: http://comesep.aeronomy.be) to forecast solar energetic particles (SEP) and coronal mass ejection (CME) risk levels at Earth. COMESEP alert system uses automated detection tool CACTus to detect potentially threatening CMEs, drag-based model (DBM) to predict their arrival and CME geo-effectiveness tool (CGFT) to predict their geomagnetic impact. Whenever CACTus detects a halo or partial halo CME and issues an alert, DBM calculates its arrival time at Earth and CGFT calculates its geomagnetic risk level. Geomagnetic risk level is calculated based on an estimation of the CME arrival probability and its likely geo-effectiveness, as well as an estimate of the geomagnetic-storm duration. We present the evaluation of the CME risk level forecast with COMESEP alert system based on a study of geo-effective CMEs observed during 2014. The validation of the forecast tool is done by comparing the forecasts with observations. In addition, we test the success rate of the automatic forecasts (without human intervention) against the forecasts with human intervention using advanced versions of DBM and CGFT (self standing tools available at Hvar Observatory website: http://oh.geof.unizg.hr). The results implicate that the success rate of the forecast is higher with human intervention and using more advanced tools. This work has received funding from the European Commission FP7 Project COMESEP (263252). We acknowledge the support of Croatian Science Foundation under the project 6212 „Solar and Stellar Variability".

  13. Primary Mucoepidermoid Carcinoma of the Lacrimal Sac -  a Case Report and Literature Review.

    PubMed

    Janakiram, T N; Sagar, S; Sharma, S B; Subramaniam, V

    Lacrimal sac tumors are very rare and are often missed because patients present with features consistent with chronic dacryocystitis. Squamous cell carcinoma is the common-est lacrimal sac malignancy. Although primary mucoepidermoid carcinomas of the lacrimal sac are rare, they are locally aggressive. Furthermore, their proximity to vital structures and the skull base makes them potentially life-threatening. Multidisciplinary management is required, and wide excision followed by chemoradiation is the recommended treatment. Here, we report a 65-year-old male who presented with watering eyes and a mass in the region of the medial canthus. A dia-gnosis of primary mucoepidermoid carcinoma of the lacrimal sac was made, and the case was managed successfully with radical surgery and reconstruction. The tumor was resected using the extended Lynch-Howarth incision and the resulting defect was reconstructed using a forehead flap. Histopathological examination of the excised specimen revealed mucoepidermoid carcinoma. Immunohistochemical analysis revealed that the speci-men was positive for epithelial growth factor receptor and Ki-67 protein. The patient was referred for post-operative chemoradiation. The literature is reviewed and pathological features, including immunohistochemistry are discussed. Primary mucoepidermoid carcinoma of the lacrimal sac is a rare, locally aggressive tumor that is often mistaken for dacryocystitis. The treatment of choice is radical surgery followed by chemoradiation. lacrimal sac -  mucoepidermoid carcinoma -  epithelial growth factor receptor -  Ki-67 protein.

  14. Speech Auditory Alerts Promote Memory for Alerted Events in a Video-Simulated Self-Driving Car Ride.

    PubMed

    Nees, Michael A; Helbein, Benji; Porter, Anna

    2016-05-01

    Auditory displays could be essential to helping drivers maintain situation awareness in autonomous vehicles, but to date, few or no studies have examined the effectiveness of different types of auditory displays for this application scenario. Recent advances in the development of autonomous vehicles (i.e., self-driving cars) have suggested that widespread automation of driving may be tenable in the near future. Drivers may be required to monitor the status of automation programs and vehicle conditions as they engage in secondary leisure or work tasks (entertainment, communication, etc.) in autonomous vehicles. An experiment compared memory for alerted events-a component of Level 1 situation awareness-using speech alerts, auditory icons, and a visual control condition during a video-simulated self-driving car ride with a visual secondary task. The alerts gave information about the vehicle's operating status and the driving scenario. Speech alerts resulted in better memory for alerted events. Both auditory display types resulted in less perceived effort devoted toward the study tasks but also greater perceived annoyance with the alerts. Speech auditory displays promoted Level 1 situation awareness during a simulation of a ride in a self-driving vehicle under routine conditions, but annoyance remains a concern with auditory displays. Speech auditory displays showed promise as a means of increasing Level 1 situation awareness of routine scenarios during an autonomous vehicle ride with an unrelated secondary task. © 2016, Human Factors and Ergonomics Society.

  15. Alertness function of thalamus in conflict adaptation.

    PubMed

    Wang, Xiangpeng; Zhao, Xiaoyue; Xue, Gui; Chen, Antao

    2016-05-15

    Conflict adaptation reflects the ability to improve current conflict resolution based on previously experienced conflict, which is crucial for our goal-directed behaviors. In recent years, the roles of alertness are attracting increasing attention when discussing the generation of conflict adaptation. However, due to the difficulty of manipulating alertness, very limited progress has been made in this line. Inspired by that color may affect alertness, we manipulated background color of experimental task and found that conflict adaptation significantly presented in gray and red backgrounds but did not in blue background. Furthermore, behavioral and functional magnetic resonance imaging results revealed that the modulation of color on conflict adaptation was implemented through changing alertness level. In particular, blue background eliminated conflict adaptation by damping the alertness regulating function of thalamus and the functional connectivity between thalamus and inferior frontal gyrus (IFG). In contrast, in gray and red backgrounds where alertness levels are typically high, the thalamus and the right IFG functioned normally and conflict adaptations were significant. Therefore, the alertness function of thalamus is determinant to conflict adaptation, and thalamus and right IFG are crucial nodes of the neural circuit subserving this ability. Present findings provide new insights into the neural mechanisms of conflict adaptation. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Automatic segmentation and classification of gestational sac based on mean sac diameter using medical ultrasound image

    NASA Astrophysics Data System (ADS)

    Khazendar, Shan; Farren, Jessica; Al-Assam, Hisham; Sayasneh, Ahmed; Du, Hongbo; Bourne, Tom; Jassim, Sabah A.

    2014-05-01

    Ultrasound is an effective multipurpose imaging modality that has been widely used for monitoring and diagnosing early pregnancy events. Technology developments coupled with wide public acceptance has made ultrasound an ideal tool for better understanding and diagnosing of early pregnancy. The first measurable signs of an early pregnancy are the geometric characteristics of the Gestational Sac (GS). Currently, the size of the GS is manually estimated from ultrasound images. The manual measurement involves multiple subjective decisions, in which dimensions are taken in three planes to establish what is known as Mean Sac Diameter (MSD). The manual measurement results in inter- and intra-observer variations, which may lead to difficulties in diagnosis. This paper proposes a fully automated diagnosis solution to accurately identify miscarriage cases in the first trimester of pregnancy based on automatic quantification of the MSD. Our study shows a strong positive correlation between the manual and the automatic MSD estimations. Our experimental results based on a dataset of 68 ultrasound images illustrate the effectiveness of the proposed scheme in identifying early miscarriage cases with classification accuracies comparable with those of domain experts using K nearest neighbor classifier on automatically estimated MSDs.

  17. Circular dichroism spectra of uridine derivatives: ChiraSac study.

    PubMed

    Miyahara, Tomoo; Nakatsuji, Hiroshi; Wada, Takehiko

    2014-04-24

    The experimental circular dichroism (CD) spectra of uridine and NH2-uridine that were different in the intensity and shape were studied in the light of the ChiraSac method. The theoretical CD spectra at several different conformations using the symmetry-adapted-cluster configuration-interaction (SAC-CI) theory largely depended on the conformational angle, but those of the anti-conformers and the Boltzmann average reproduced the experimentally obtained CD spectra of both uridine and NH2-uridine. The differences in the CD spectra between the two uridine derivatives were analyzed by using the angle θ between the electric transition dipole moment (ETDM) and the magnetic transition dipole moment (MTDM).

  18. Slope-Area Computation Program Graphical User Interface 1.0—A Preprocessing and Postprocessing Tool for Estimating Peak Flood Discharge Using the Slope-Area Method

    USGS Publications Warehouse

    Bradley, D. Nathan

    2012-01-01

    The slope-area method is a technique for estimating the peak discharge of a flood after the water has receded (Dalrymple and Benson, 1967). This type of discharge estimate is called an “indirect measurement” because it relies on evidence left behind by the flood, such as high-water marks (HWMs) on trees or buildings. These indicators of flood stage are combined with measurements of the cross-sectional geometry of the stream, estimates of channel roughness, and a mathematical model that balances the total energy of the flow between cross sections. This is in contrast to a “direct” measurement of discharge during the flood where cross-sectional area is measured and a current meter or acoustic equipment is used to measure the water velocity. When a direct discharge measurement cannot be made at a gage during high flows because of logistics or safety reasons, an indirect measurement of a peak discharge is useful for defining the high-flow section of the stage-discharge relation (rating curve) at the stream gage, resulting in more accurate computation of high flows. The Slope-Area Computation program (SAC; Fulford, 1994) is an implementation of the slope-area method that computes a peak-discharge estimate from inputs of water-surface slope (from surveyed HWMs), channel geometry, and estimated channel roughness. SAC is a command line program written in Fortran that reads input data from a formatted text file and prints results to another formatted text file. Preparing the input file can be time-consuming and prone to errors. This document describes the SAC graphical user interface (GUI), a crossplatform “wrapper” application that prepares the SAC input file, executes the program, and helps the user interpret the output. The SAC GUI is an update and enhancement of the slope-area method (SAM; Hortness, 2004; Berenbrock, 1996), an earlier spreadsheet tool used to aid field personnel in the completion of a slope-area measurement. The SAC GUI reads survey data

  19. Safety Alerts: An Observational Study in Portugal.

    PubMed

    Soares, Sara; Roque, Fátima; Teixeira Rodrigues, António; Figueiras, Adolfo; Herdeiro, Maria Teresa

    2015-09-01

    The information that is available when marketing authorizations are approved is limited. Pharmacovigilance has an important role during the postauthorization period, and alerts published by national authorities allow health care professionals to be informed about new data on safety profiles. This study therefore sought to analyze all safety alerts published by the Portuguese National Authority of Medicines and Health Products I.P. (INFARMED). We conducted an observational study of all alerts published on the INFARMED website from January 2002 through December 2014. From the data included in the alerts, the following information was abstracted: active substance name (and trade name), event that led to the alert, and the resulting safety measures. Active substances were classified according to the Anatomical Therapeutic Chemical (ATC) code. A total of 562 alerts were published, and 304 were eligible for inclusion. The musculoskeletal system was the ATC code with more alerts (n = 53), followed by the nervous system (n = 42). Communication of the information and recommendations to the health care professionals and the public in general was the most frequent safety measure (n = 128), followed by changes in the Summary of the Product Characteristics and package information leaflet (n = 66). During the study period, 26 marketing authorizations were temporarily suspended and 10 were revoked. The knowledge of the alerts published during the postmarketing period is very useful to the health care professionals for improving prescription and use of medicines and to the scientific community for the development of new researches. Copyright © 2015 Elsevier HS Journals, Inc. All rights reserved.

  20. Sac1--Vps74 structure reveals a mechanism to terminate phosphoinositide signaling in the Golgi apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai, Yiying; Deng, Yongqiang; Horenkamp, Florian

    2014-08-25

    Sac1 is a phosphoinositide phosphatase of the endoplasmic reticulum and Golgi apparatus that controls organelle membrane composition principally via regulation of phosphatidylinositol 4-phosphate signaling. We present a characterization of the structure of the N-terminal portion of yeast Sac1, containing the conserved Sac1 homology domain, in complex with Vps74, a phosphatidylinositol 4-kinase effector and the orthologue of human GOLPH3. The interface involves the N-terminal subdomain of the Sac1 homology domain, within which mutations in the related Sac3/Fig4 phosphatase have been linked to Charcot–Marie–Tooth disorder CMT4J and amyotrophic lateral sclerosis. Disruption of the Sac1–Vps74 interface results in a broader distribution of phosphatidylinositolmore » 4-phosphate within the Golgi apparatus and failure to maintain residence of a medial Golgi mannosyltransferase. The analysis prompts a revision of the membrane-docking mechanism for GOLPH3 family proteins and reveals how an effector of phosphoinositide signaling serves a dual function in signal termination.« less

  1. IP telephony based danger alert communication system and its implementation

    NASA Astrophysics Data System (ADS)

    Rezac, Filip; Safarik, Jakub; Voznak, Miroslav; Tomala, Karel; Partila, Pavol

    2013-05-01

    This article discusses a danger alert system created as a part of the research project at Department of Telecommunications of Technical University of Ostrava. The aim of the system is to distribute pre-recorded voice messages in order to alert the called party in danger. This article describes individual technologies, which the application uses for its operation as well as issues relating to hardware requirements and transfer line bandwidth load. The article also describes new algorithms, which had to be developed in order to ensure the reliability of the system. Our intent is focused on disaster management, the message, which should be delivered within specified time span, is typed in the application and text-to-speech module ensures its transformation to a speech format, after that a particular scenario or warned area is selected and a target group is automatically unloaded. For this purpose, we have defined XML format for delivery of phone numbers which are located in the target area and these numbers are obtained from mobile BTS's (Base transmission stations). The benefit of such communication compared to others, is the fact, that it uses a phone call and, therefore, it is possible to get feedback who accepted the message and to improve efficiency of alert system. Finally, the list of unanswered calls is exported and these users can be informed via SMS.

  2. Selective Intra-procedural AAA sac Embolization During EVAR Reduces the Rate of Type II Endoleak.

    PubMed

    Mascoli, C; Freyrie, A; Gargiulo, M; Gallitto, E; Pini, R; Faggioli, G; Serra, C; De Molo, C; Stella, A

    2016-05-01

    The pre-treatment presence of at least six efferent patent vessels (EPV) from the AAA sac and/or AAA thrombus volume ratio (VR%) <40% are considered to be positive predictive factors for persistent type II endoleak (ELIIp). The aim of the present study was to evaluate the effectiveness of sac embolization during EVAR in patients with pre-operative morphological risk factors (p-MRF) for ELIIp. Patients undergoing EVAR and intra-procedural AAA sac embolization (Group A, 2012-2013) were retrospectively selected and compared with a control group of patients with the same p-MRF, who underwent EVAR without intra-procedural sac embolization (Group B, 2008-2010). The presence of ELIIp was evaluated by duplex ultrasound at 0 and 6 months, and by contrast enhanced ultrasound at 12 months. The association between AAA diameter, age, COPD, smoking, anticoagulant therapy, and AAA sac embolization with ELIIp was evaluated using multiple logistic regression. The primary endpoint was the effectiveness of the intra-procedural AAA sac embolization for ELIIp prevention. Secondary endpoints were AAA sac evolution and freedom from ELIIp and embolization related re-interventions at 6-12 months. Seventy patients were analyzed: 26 Group A and 44 Group B; the groups were homogeneous for clinical/morphological characteristics. In Group A the median number of coils positioned in AAA sac was 4.1 (IQR 1). There were no complications related to the embolization procedures. A significantly lower number of ELIIp was detected in Group A than in Group B (8/26 vs. 33/44, respectively, p < .001) at discharge, and this was confirmed at 6-12 months (7/26 vs. 30/44 respectively, p = .001, and 5/25 vs. 32/44, respectively, p < .001). On multivariate analysis, intra-procedural AAA sac embolization was the only factor independently associated with freedom from ELIIp at 6 (OR 0.196, 95% CI 0.06-0.63; p = .007) and 12 months (OR 0.098, 95% CI 0.02-0.35; p < .001). No differences in median AAA sac

  3. Pilot Non-Conformance to Alerting System Commands

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy R.; Hansman, R. John

    1997-01-01

    Instances of pilot non-conformance to alerting system commands have been identified in previous studies. Pilot non-conformance changes the final behavior of the system, and therefore may reduce actual performance from that anticipated. A simulator study has examined pilot non-conformance, using the task of collision avoidance during closely spaced parallel approaches as a case study. Consonance between the display and the alerting system was found to significantly improve subject agreement with automatic alerts. Based on these results, a more general discussion of the factors involved in pilot conformance is given, and design guidelines for alerting systems are given.

  4. The Common Alerting Protocol (CAP) adaption in National Early Warning Alerting Systems of China

    NASA Astrophysics Data System (ADS)

    Li, Chao

    2017-04-01

    The Common Alerting Protocol (CAP) [1] is an XML-based data format for exchanging public warnings and emergencies between alerting technologies. In China, from local communities to entire nations, there was a patchwork of specialized hazard public alerting systems. And each system was often designed just for certain emergency situations and for certain communications media. Application took place in the NEWAS (National Early Warning Alerting Systems) [2]project where CAP serves as central message to integrate all kind of hazard situations, including the natural calamity, accident disaster, public health emergency , social safety etc. Officially operated on May 2015, NEWAS now has completed docking work with 14 departments including civil administration, safety supervision, forestry, land, water conservancy, earthquake, traffic, meteorology, agriculture, tourism, food and drug supervision, public security and oceanic administration. Thus, several items in CAP has been modified, redefined and extended according to the various grading standards and publishing strategies, as well as the characteristics of Chinese Geocoding. NEWAS successfully delivers information to end users through 4 levels (i.e. State, province, prefecture and county) structure and by various means. [1] CAP, http://www.oasis-emergency.org/cap [2] http://www.12379.cn/

  5. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  6. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  7. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  8. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  9. 47 CFR 10.310 - Federal alert gateway. [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Federal alert gateway. [Reserved] 10.310 Section 10.310 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.310 Federal alert gateway. [Reserved] ...

  10. Wireless Emergency Alerts: New York City Demonstration

    DTIC Science & Technology

    2013-06-01

    CMU/SEI-2012-SR-016 | 16  Consider factors affecting continuity of operations, such as support of remote employ- ees, mobile alerting...visitors and tourists , we’ll be even safer when authorities can broadcast warnings to everyone in a geographic area regardless of where they came from or...using technology to help keep people safe. [Office of the Mayor 2011b] Mayor Bloomberg declared his intention to make this new service available to New

  11. Alertness and cognitive control: Testing the early onset hypothesis.

    PubMed

    Schneider, Darryl W

    2018-05-01

    Previous research has revealed a peculiar interaction between alertness and cognitive control in selective-attention tasks: Congruency effects are larger on alert trials (on which an alerting cue is presented briefly in advance of the imperative stimulus) than on no-alert trials, despite shorter response times (RTs) on alert trials. One explanation for this finding is the early onset hypothesis, which is based on the assumptions that increased alertness shortens stimulus-encoding time and that cognitive control involves gradually focusing attention during a trial. The author tested the hypothesis in 3 experiments by manipulating alertness and stimulus quality (which were intended to shorten and lengthen stimulus-encoding time, respectively) in an arrow-based flanker task involving congruent and incongruent stimuli. Replicating past findings, the alerting manipulation led to shorter RTs but larger congruency effects on alert trials than on no-alert trials. The stimulus-quality manipulation led to longer RTs and larger congruency effects for degraded stimuli than for intact stimuli. These results provide mixed support for the early onset hypothesis, but the author discusses how data and theory might be reconciled if stimulus quality affects stimulus-encoding time and the rate of evidence accumulation in the decision process. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Aquarius/SAC-D mission overview

    NASA Astrophysics Data System (ADS)

    Sen, Amit; Kim, Yunjin; Caruso, Daniel; Lagerloef, Gary; Colomb, Raul; Yueh, Simon; Le Vine, David

    2006-09-01

    Aquarius/SAC-D is a cooperative international mission developed between the National Aeronautics and Space Administration (NASA) of United States of America (USA) and the Comisión Nacional de Actividades Espaciales (CONAE) of Argentina. The overall mission objective is to contribute to the understanding of the total Earth system and the consequences of the natural and man-made changes in the environment of the planet. Major themes are: ocean surface salinity, carbon, water cycle, geo-hazards, and cryosphere.

  13. Anatomy and histology of the newly discovered adipose sac structure within the labia majora: international original research.

    PubMed

    Ostrzenski, Adam; Krajewski, Pawel; Davis, Kern

    2016-09-01

    To determine whether there is any new anatomical structure present within the labia majora. A case serial study was executed on eleven consecutive fresh human female cadavers. Stratum-by-stratum dissections of the labia majora were performed. Twenty-two anatomic dissections of labia majora were completed. Eosin and Hematoxylin agents were used to stain newly discovered adipose sac's tissues of the labia majora and the cylinder-like structures, which cover condensed adipose tissues. The histology of these two structures was compared. All dissected labia majora demonstrated the presence of the anatomic existence of the adipose sac structure. Just under the dermis of the labia majora, the adipose sac was located, which was filled with lobules containing condensed fatty tissues in the form of cylinders. The histological investigation established that the well-organized fibro-connective-adipose tissues represented the adipose sac. The absence of descriptions of the adipose sac within the labia majora in traditional anatomic and gynecologic textbooks was noted. In this study group, the newly discovered adipose sac is consistently present within the anatomical structure of the labia majora. The well-organized fibro-connective-adipose tissue represents microscopic characteristic features of the adipose sac.

  14. Rectal sac distention is induced by 20-hydroxyecdysone in the pupa of Bombyx mori.

    PubMed

    Suzuki, Takumi; Sakurai, Sho; Iwami, Masafumi

    2009-03-01

    Holometabolous insects do not excrete but store metabolic wastes during the pupal period. The waste is called meconium and is purged after adult emergence. Although the contents of meconium are well-studied, the developmental and physiological regulation of meconium accumulation is poorly understood. In Bombyx mori, meconium is accumulated in the rectal sac; thereby, the rectal sac distends at the late pupal stage. Here, we show that rectal sac distention occurs between 4 and 5 days after pupation. The distention is halted by brain-removal just after larval-pupal ecdysis but not by brain-removal 1 day after pupation. In the pupae, brain-removal just after ecdysis kept the hemolymph ecdysteroid titer low during early and mid-pupal stages. An injection of 20-hydroxyecdysone (20E) evoked the distention that was halted by brain-removal in a dose-dependent manner. Therefore, brain-removal caused the lack of ecdysteroid, and rectal sac distention did not appear in the brain-removed pupae because of the lack of ecdysteroid. We conclude that rectal sac distention is one of the developmental events regulated by 20E during the pupal period in B. mori.

  15. 76 FR 80780 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules governing the Emergency Alert System (EAS) rules to extend the deadline for EAS Participants to be able to receive Common Alerting Protocol (CAP)- formatted EAS alerts to...

  16. An IDS Alerts Aggregation Algorithm Based on Rough Set Theory

    NASA Astrophysics Data System (ADS)

    Zhang, Ru; Guo, Tao; Liu, Jianyi

    2018-03-01

    Within a system in which has been deployed several IDS, a great number of alerts can be triggered by a single security event, making real alerts harder to be found. To deal with redundant alerts, we propose a scheme based on rough set theory. In combination with basic concepts in rough set theory, the importance of attributes in alerts was calculated firstly. With the result of attributes importance, we could compute the similarity of two alerts, which will be compared with a pre-defined threshold to determine whether these two alerts can be aggregated or not. Also, time interval should be taken into consideration. Allowed time interval for different types of alerts is computed individually, since different types of alerts may have different time gap between two alerts. In the end of this paper, we apply proposed scheme on DAPRA98 dataset and the results of experiment show that our scheme can efficiently reduce the redundancy of alerts so that administrators of security system could avoid wasting time on useless alerts.

  17. Driver alertness and fatigue : summary of completed research projects, 1995-98

    DOT National Transportation Integrated Search

    2000-01-01

    This document describes projects in the Federal Motor Carrier Safety Administration's (FMCSA) Driver Alertness and Fatigue Research and Technology (R&T) focus area that were completed during the years 1995 to 1998 under the former Office of Motor Car...

  18. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  19. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL WIRELESS EMERGENCY ALERTS System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  20. Outlier Detection for Patient Monitoring and Alerting

    PubMed Central

    Hauskrecht, Milos; Batal, Iyad; Valko, Michal; Visweswaran, Shyam; Cooper, Gregory F.; Clermont, Gilles

    2012-01-01

    We develop and evaluate a data-driven approach for detecting unusual (anomalous) patient-management decisions using past patient cases stored in electronic health records (EHRs). Our hypothesis is that a patient-management decision that is unusual with respect to past patient care may be due to an error and that it is worthwhile to generate an alert if such a decision is encountered. We evaluate this hypothesis using data obtained from EHRs of 4,486 post-cardiac surgical patients and a subset of 222 alerts generated from the data. We base the evaluation on the opinions of a panel of experts. The results of the study support our hypothesis that the outlier-based alerting can lead to promising true alert rates. We observed true alert rates that ranged from 25% to 66% for a variety of patient-management actions, with 66% corresponding to the strongest outliers. PMID:22944172

  1. Alerts in mobile healthcare applications: requirements and pilot study.

    PubMed

    Kafeza, Eleanna; Chiu, Dickson K W; Cheung, S C; Kafeza, Marina

    2004-06-01

    Recent advances in mobile technologies have greatly extended traditional communication technologies to mobile devices. At the same time, healthcare environments are by nature "mobile" where doctors and nurses do not have fixed workspaces. Irregular and exceptional events are generated in daily hospital routines, such as operations rescheduling, laboratory/examination results, and adverse drug events. These events may create requests that should be delivered to the appropriate person at the appropriate time. Those requests that are classified as urgent are referred to as alerts. Efficient routing and monitoring of alerts are keys to quality and cost-effective healthcare services. Presently, these are generally handled in an ad hoc manner. In this paper, we propose the use of a healthcare alert management system to handle these alert messages systematically. We develop a model for specifying alerts that are associated with medical tasks and a set of parameters for their routing. We design an alert monitor that matches medical staff and their mobile devices to receive alerts, based on the requirements of these alerts. We also propose a mechanism to handle and reroute, if necessary, an alert message when it has not been acknowledged within a specific deadline.

  2. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM System Architecture § 10.320 Provider alert gateway requirements. This section specifies the functions...

  3. Perceptual evaluation of visual alerts in surveillance videos

    NASA Astrophysics Data System (ADS)

    Rogowitz, Bernice E.; Topkara, Mercan; Pfeiffer, William; Hampapur, Arun

    2015-03-01

    Visual alerts are commonly used in video monitoring and surveillance systems to mark events, presumably making them more salient to human observers. Surprisingly, the effectiveness of computer-generated alerts in improving human performance has not been widely studied. To address this gap, we have developed a tool for simulating different alert parameters in a realistic visual monitoring situation, and have measured human detection performance under conditions that emulated different set-points in a surveillance algorithm. In the High-Sensitivity condition, the simulated alerts identified 100% of the events with many false alarms. In the Lower-Sensitivity condition, the simulated alerts correctly identified 70% of the targets, with fewer false alarms. In the control condition, no simulated alerts were provided. To explore the effects of learning, subjects performed these tasks in three sessions, on separate days, in a counterbalanced, within subject design. We explore these results within the context of cognitive models of human attention and learning. We found that human observers were more likely to respond to events when marked by a visual alert. Learning played a major role in the two alert conditions. In the first session, observers generated almost twice as many False Alarms as in the No-Alert condition, as the observers responded pre-attentively to the computer-generated false alarms. However, this rate dropped equally dramatically in later sessions, as observers learned to discount the false cues. Highest observer Precision, Hits/(Hits + False Alarms), was achieved in the High Sensitivity condition, but only after training. The successful evaluation of surveillance systems depends on understanding human attention and performance.

  4. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  5. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  6. 16 CFR 613.1 - Duration of active duty alerts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Duration of active duty alerts. 613.1 Section 613.1 Commercial Practices FEDERAL TRADE COMMISSION THE FAIR CREDIT REPORTING ACT DURATION OF ACTIVE DUTY ALERTS § 613.1 Duration of active duty alerts. The duration of an active duty alert shall be...

  7. Earthquake early Warning ShakeAlert system: West coast wide production prototype

    USGS Publications Warehouse

    Kohler, Monica D.; Cochran, Elizabeth S.; Given, Douglas; Guiwits, Stephen; Neuhauser, Doug; Hensen, Ivan; Hartog, Renate; Bodin, Paul; Kress, Victor; Thompson, Stephen; Felizardo, Claude; Brody, Jeff; Bhadha, Rayo; Schwarz, Stan

    2017-01-01

    Earthquake early warning (EEW) is an application of seismological science that can give people, as well as mechanical and electrical systems, up to tens of seconds to take protective actions before peak earthquake shaking arrives at a location. Since 2006, the U.S. Geological Survey has been working in collaboration with several partners to develop EEW for the United States. The goal is to create and operate an EEW system, called ShakeAlert, for the highest risk areas of the United States, starting with the West Coast states of California, Oregon, and Washington. In early 2016, the Production Prototype v.1.0 was established for California; then, in early 2017, v.1.2 was established for the West Coast, with earthquake notifications being distributed to a group of beta users in California, Oregon, and Washington. The new ShakeAlert Production Prototype was an outgrowth from an earlier demonstration EEW system that began sending test notifications to selected users in California in January 2012. ShakeAlert leverages the considerable physical, technical, and organizational earthquake monitoring infrastructure of the Advanced National Seismic System, a nationwide federation of cooperating seismic networks. When fully implemented, the ShakeAlert system may reduce damage and injury caused by large earthquakes, improve the nation’s resilience, and speed recovery.

  8. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Ship Security Alert System (SSAS). 80.277... Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety..., “RTCM Standard 11020.0—Ship Security Alert Systems (SSAS) using the Cospas-Sarsat System,” Version 1.0...

  9. Solutions Network Formulation Report. Reducing Light Pollution in U.S. Coastal Regions Using the High Sensitivity Cameras on the SAC-C and Aquarius/SAC-D Satellites

    NASA Technical Reports Server (NTRS)

    Andrews, Jane C.; Knowlton, Kelly

    2007-01-01

    Light pollution has significant adverse biological effects on humans, animals, and plants and has resulted in the loss of our ability to view the stars and planets of the universe. Over half of the U.S. population resides in coastal regions where it is no longer possible to see the stars and planets in the night sky. Forty percent of the entire U.S. population is never exposed to conditions dark enough for their eyes to convert to night vision capabilities. In coastal regions, urban lights shine far out to sea where they are augmented by the output from fishing boat, cruise ship and oil platform floodlights. The proposed candidate solution suggests using HSCs (high sensitivity cameras) onboard the SAC-C and Aquarius/SAC-D satellites to quantitatively evaluate light pollution at high spatial resolution. New products modeled after pre-existing, radiance-calibrated, global nighttime lights products would be integrated into a modified Garstang model where elevation, mountain screening, Rayleigh scattering, Mie scattering by aerosols, and atmospheric extinction along light paths and curvature of the Earth would be taken into account. Because the spatial resolution of the HSCs on SAC-C and the future Aquarius/SAC-D missions is greater than that provided by the DMSP (Defense Meteorological Satellite Program) OLS (Operational Linescan System) or VIIRS (Visible/Infrared Imager/Radiometer Suite), it may be possible to obtain more precise light intensity data for analytical DSSs and the subsequent reduction in coastal light pollution.

  10. The Zwicky Transient Facility Public Alert Stream

    NASA Astrophysics Data System (ADS)

    Masci, F.; Kulkarni, S. R.; Graham, M.; Prince, T.; Helou, G.

    2018-06-01

    The Zwicky Transient Facility (ZTF; ATel #11266) announces the start of public alerts. These alerts will originate from the ZTF public surveys (Bellm & Kulkarni 2017; Nature Astronomy 1, 71) as described at www.ztf.caltech.edu/page/msip Alerts are generated by the ZTF Science Data System housed at IPAC-Caltech (www.ipac.caltech.edu) using a realtime image-subtraction pipeline (Masci et al. 2018; www.ztf.caltech.edu/page/technical).

  11. Wireless clinical alerts for physiologic, laboratory and medication data.

    PubMed Central

    Shabot, M. M.; LoBue, M.; Chen, J.

    2000-01-01

    A fully interfaced clinical information system (CIS) contains physiologic, laboratory, blood gas, medication and other data that can be used as the information base for a comprehensive alerting system. Coupled with an event driven rules engine, a CIS can generate clinical alerts which may both prevent medical errors and assist caregivers in responding to critical events in a timely way. The authors have developed a clinical alerting system which delivers alerts and reminders to clinicians in real time via a alphanumeric display pagers. This paper will describe the system, the type and number of alerts generated, and the impact on clinical practice. A major issue remains in measuring the impact of wireless alerts on patient outcomes. PMID:11079992

  12. [Chemotherapy of yolk sac tumor heterotransplanted to nude mice (author's transl)].

    PubMed

    Sawada, M; Hayakawa, K; Matsui, Y; Nishiura, H; Okudaira, Y

    1980-10-01

    Chemotherapy of yolk sac tumor heterotransplanted to nude mice was studied. 1. Yolk sac tumor of the ovary taken from a 38-year -old woman was transplanted to BALB/c female nude mice. The transplantable tumor cells produce a solid tumor, designated as YST-1 tumor. The YST-1 tumor cells preserve the histological appearance of a human yolk sac tumor and produce x-fetoprotein. The tumors on passage 8 were used for experimental chemotherapy. 2. Anticancer drugs clinically known to be effective for ovarian cancer, such as Adriamycin, Carbazilquinone, 5-Fluorouracil, Cyclophosphamide, Mitomycin C, Chromomycin A3, Vinblastine and Bleomycin were administered intraperitoneally to tumor-bearing nude mice. Tumor size was measured two or three times a week during the course of experiments. Therapeutic effects were evaluated by tumor size and relative tumor size before and after experiments. Among these drugs, Vinblastine and Bleomycin combination showed the significant effect arresting the growth of YST-1 tumor.

  13. A low-cost wireless system for autonomous generation of road safety alerts

    NASA Astrophysics Data System (ADS)

    Banks, B.; Harms, T.; Sedigh Sarvestani, S.; Bastianini, F.

    2009-03-01

    This paper describes an autonomous wireless system that generates road safety alerts, in the form of SMS and email messages, and sends them to motorists subscribed to the service. Drivers who regularly traverse a particular route are the main beneficiaries of the proposed system, which is intended for sparsely populated rural areas, where information available to drivers about road safety, especially bridge conditions, is very limited. At the heart of this system is the SmartBrick, a wireless system for remote structural health monitoring that has been presented in our previous work. Sensors on the SmartBrick network regularly collect data on water level, temperature, strain, and other parameters important to safety of a bridge. This information is stored on the device, and reported to a remote server over the GSM cellular infrastructure. The system generates alerts indicating hazardous road conditions when the data exceeds thresholds that can be remotely changed. The remote server and any number of designated authorities can be notified by email, FTP, and SMS. Drivers can view road conditions and subscribe to SMS and/or email alerts through a web page. The subscription-only form of alert generation has been deliberately selected to mitigate privacy concerns. The proposed system can significantly increase the safety of travel through rural areas. Real-time availability of information to transportation authorities and law enforcement officials facilitates early or proactive reaction to road hazards. Direct notification of drivers further increases the utility of the system in increasing the safety of the traveling public.

  14. Insider Alert 1.0 Beta Version

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, Robert

    2004-02-01

    Insider Alert 1.0 Beta Version supports interactive selection and graphical display of data generated by the Sandia Cognitive Framework, which simulates the examination of security data by experts of various specialties. Insider Alert also encompasses the configuration and data files input to the Cognitive Framework for this application. Insider Alert 1.0 Beta Version is a computer program for analyzing data indicative of possible espionage or improper handling of data by employees at Sandia National Laboratories (or other facilities with comparable policies and procedures for managing sensitive information) It prioritizes and displays information for review by security analysts.

  15. Analysis of Alerting System Failures in Commercial Aviation Accidents

    NASA Technical Reports Server (NTRS)

    Mumaw, Randall J.

    2017-01-01

    The role of an alerting system is to make the system operator (e.g., pilot) aware of an impending hazard or unsafe state so the hazard can be avoided or managed successfully. A review of 46 commercial aviation accidents (between 1998 and 2014) revealed that, in the vast majority of events, either the hazard was not alerted or relevant hazard alerting occurred but failed to aid the flight crew sufficiently. For this set of events, alerting system failures were placed in one of five phases: Detection, Understanding, Action Selection, Prioritization, and Execution. This study also reviewed the evolution of alerting system schemes in commercial aviation, which revealed naive assumptions about pilot reliability in monitoring flight path parameters; specifically, pilot monitoring was assumed to be more effective than it actually is. Examples are provided of the types of alerting system failures that have occurred, and recommendations are provided for alerting system improvements.

  16. Alerts Visualization and Clustering in Network-based Intrusion Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dr. Li; Gasior, Wade C; Dasireddy, Swetha

    2010-04-01

    Today's Intrusion detection systems when deployed on a busy network overload the network with huge number of alerts. This behavior of producing too much raw information makes it less effective. We propose a system which takes both raw data and Snort alerts to visualize and analyze possible intrusions in a network. Then we present with two models for the visualization of clustered alerts. Our first model gives the network administrator with the logical topology of the network and detailed information of each node that involves its associated alerts and connections. In the second model, flocking model, presents the network administratormore » with the visual representation of IDS data in which each alert is represented in different color and the alerts with maximum similarity move together. This gives network administrator with the idea of detecting various of intrusions through visualizing the alert patterns.« less

  17. Physiological requirements for 20-hydroxyecdysone-induced rectal sac distention in the pupa of the silkworm, Bombyx mori.

    PubMed

    Suzuki, Takumi; Sakurai, Sho; Iwami, Masafumi

    2010-06-01

    Successful insect development is achieved via appropriate fluctuation of ecdysteroid levels. When an insect's ecdysteroid level is disrupted, physiological and developmental defects occur. In the pupa of the silkworm, Bombyx mori, the rectal sac is an essential organ that operates as a repository for degraded ecdysteroids, and it can be distended by administration of 20-hydroxyecdysone (20E). Our previous study showed that rectal sac distention appears 4 days after 20E administration. Hemolymph ecdysteroid levels, however, decrease to lower level during this period. Thus, the timing of the rectal sac distention does not match with that of ecdysteroid elevation. Here, we examine how 20E induces rectal sac distention. A ligature experiment and ecdysteroid quantification showed that continuous 20E stimulation induces rectal sac distention. Thorax tissue contributed to the continuous 20E stimulation needed to induce distention. Ecdysteroid released from the thorax tissue may be converted to 20E by ecdysone 20-hydroxylase to produce continuous 20E stimulation. Thus, the ecdysone metabolic pathway plays a critical role in rectal sac distention. Copyright 2010 Elsevier Ltd. All rights reserved.

  18. Electromigration effect on intermetallic growth and Young's modulus in SAC solder joint

    NASA Astrophysics Data System (ADS)

    Xu, Luhua; Pang, John H. L.; Ren, Fei; Tu, K. N.

    2006-12-01

    Solid-state intermetallic compound (IMC) growth behavior plays and important role in solder joint reliability of electronic packaging assemblies. The directional impact of electromigration (EM) on the growth of interfacial IMCs in Ni/SAC/Ni, Cu/SAC/Ni single BGA ball solder joint, and fine pitch ball-grid-array (FPBGA) at the anode and cathode sides is reported in this study. When the solder joint was subjected to a current density of 5,000 A/cm2 at 125°C or 150°C, IMC layer growth on the anode interface was faster than that on the cathode interface, and both were faster than isothermal aging due to the Joule heating effect. The EM affects the IMC growth rate, as well as the composition and mechanical properties. The Young’s modulus and hardness were measured by the nanoindentation continuous stiffness measurement (CSM) from planar IMC surfaces after EM exposure. Different values were observed at the anode and cathode. The energy-dispersive x-ray (EDX) line scan analysis was conducted at the interface from the cathode to anode to study the presence of species; Ni was found in the anode IMC at SAC/Cu in the Ni/SAC/Cu joint, but not detected when the current was reverse. Electron-probe microanalysis (EPMA) measurement on the Ni/SAC/Ni specimen also confirmed the polarized Ni and Cu distributions in cathode and anode IMCs, which were (Ni0.57Cu0.43)3Sn4 and (Cu0.73Ni0.27)6Sn5, respectively. Thus, the Young’s moduli of the IMC are 141 and 175 GPa, respectively.

  19. Development and morphology of the inverted yolk sac in the guinea pig (Cavia porcellus).

    PubMed

    Vasconcelos, Bruno Gomes; Favaron, Phelipe Oliveira; Miglino, Maria Angelica; Mess, Andrea Maria

    2013-10-01

    Although the guinea pig is an important animal model for human placentation, aspects of fetal nutrition are not fully understood, especially in regard to the yolk sac that is regarded to be essential for early development of the embryo. We investigated differentiation by means of histology, histochemistry, immunohistochemistry, and transmission electron microscopy. Data suggest that the guinea pig's yolk sac was not sufficiently developed to facilitate substantial fetal nutrition in early pregnancy. On Day 12, it was a flat, inverted, but avascular structure. This was followed by differentiation to form the typical, highly villous and vascularized condition of advanced gestation. Finally, the yolk sac degenerated toward term. We suggest that the guinea pig and other caviomorphs rely predominantly on hemotrophic nutrition via the placenta even in very early pregnancy. In contrast to the general pattern of mammals, histiotrophic nutrition via yolk sac routes seems to be most essential during mid-gestation. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Context-Sensitive Clinical Alert Packages Written in Arden Syntax.

    PubMed

    Zeckl, Julia; Adlassnig, Katharina; Fossler, Renate; Blacky, Alexander; de Bruin, Jeroen S; Koller, Walter; Rappelsberger, Andrea; Adlassnig, Klaus-Peter

    2017-01-01

    An increasing body of raw patient data is generated on each day of a patient's stay at a hospital. It is of paramount importance that critical patient information be extracted from these large data volumes and presented to the patient's clinical caregivers as early as possible. Contemporary clinical alert systems attempt to provide this service with moderate success. The efficacy of the systems is limited by the fact that they are too general to fit specific patient populations or healthcare institutions. In this study we present an extendable alerting framework implemented in Arden Syntax, which can be configured to the needs and preferences of healthcare institutions and individual patient caregivers. We illustrate the potential of this alerting framework via an alert package that analyzes hematological laboratory results with data from intensive care units at the Vienna General Hospital, Austria. The results show the effectiveness of this alert package and its ability to generate key alerts while avoiding over-alerting.

  1. The SAC Mentality: The Origins of Strategic Air Command’s Organizational Culture, 1948-51

    DTIC Science & Technology

    2015-04-01

    following World War II left SAC in a dire predicament as it faced shortages in several critical areas. In May 1946, the AAF autho- rized the command...convictions. McMullen believed in cross-training crew members and assigning them to multiple billets to compensate for manpower short- ages. The constant...atomic outfit from the Pacific theater. According to LeMay, they cleaned the supply warehouses , stocked the parts and supplies the unit needed, and

  2. Clinical Decision Support Alert Appropriateness: A Review and Proposal for Improvement

    PubMed Central

    McCoy, Allison B.; Thomas, Eric J.; Krousel-Wood, Marie; Sittig, Dean F.

    2014-01-01

    Background Many healthcare providers are adopting clinical decision support (CDS) systems to improve patient safety and meet meaningful use requirements. Computerized alerts that prompt clinicians about drug-allergy, drug-drug, and drug-disease warnings or provide dosing guidance are most commonly implemented. Alert overrides, which occur when clinicians do not follow the guidance presented by the alert, can hinder improved patient outcomes. Methods We present a review of CDS alerts and describe a proposal to develop novel methods for evaluating and improving CDS alerts that builds upon traditional informatics approaches. Our proposal incorporates previously described models for predicting alert overrides that utilize retrospective chart review to determine which alerts are clinically relevant and which overrides are justifiable. Results Despite increasing implementations of CDS alerts, detailed evaluations rarely occur because of the extensive labor involved in manual chart reviews to determine alert and response appropriateness. Further, most studies have solely evaluated alert overrides that are appropriate or justifiable. Our proposal expands the use of web-based monitoring tools with an interactive dashboard for evaluating CDS alert and response appropriateness that incorporates the predictive models. The dashboard provides 2 views, an alert detail view and a patient detail view, to provide a full history of alerts and help put the patient's events in context. Conclusion The proposed research introduces several innovations to address the challenges and gaps in alert evaluations. This research can transform alert evaluation processes across healthcare settings, leading to improved CDS, reduced alert fatigue, and increased patient safety. PMID:24940129

  3. An Obstacle Alerting System for Agricultural Application

    NASA Technical Reports Server (NTRS)

    DeMaio, Joe

    2003-01-01

    Wire strikes are a significant cause of helicopter accidents. The aircraft most at risk are aerial applicators. The present study examines the effectiveness of a wire alert delivered by way of the lightbar, a GPS-based guidance system for aerial application. The alert lead-time needed to avoid an invisible wire is compared with that to avoid a visible wire. A flight simulator was configured to simulate an agricultural application helicopter. Two pilots flew simulated spray runs in fields with visible wires, invisible wires, and no wires. The wire alert was effective in reducing wire strikes. A lead-time of 3.5 sec was required for the alert to be effective. The lead- time required was the same whether the pilot could see the wire or not.

  4. The effect of automated alerts on preoperative anemia management.

    PubMed

    Dilla, Andrew; Wisniewski, Mary Kay; Waters, Jonathan H; Triulzi, Darrell J; Yazer, Mark H

    2015-04-01

    This study evaluated the role of an automated anemia notification system that alerted providers about anemic pre-operative patients. After scheduling surgery, the alert program continuously searched the patient's laboratory data for hemoglobin value(s) in the medical record. When an anemic patient according to the World Health Oganization's criteria was identified, an email was sent to the patient's surgeon, and/or assistant, and/or patient's primary care physician suggesting that the anemia be managed before surgery. Thirteen surgeons participated in this pilot study. In 11 months, there were 70 pre-surgery anemia alerts generated on 69 patients. The surgeries were 60 orthopedic, 7 thoracic, 2 general surgery, and 1 urological. The alerts were sent 15 ± 10 days before surgery. No pre-operative anemia treatment could be found in 37 of 69 (54%) patients. Some form of anemia management was found in 32 of 69 (46%) patients. Of the 23 patients who received iron, only 3 of 23 (13%) of these patients started iron shortly after the alert was generated. The alert likely resulted in the postponement of one surgery for anemia correction. Although anemia diagnosis and management can be complex, it was hoped that receipt of the alert would lead to the management of all anemic patients. Alerts are only effective if they are received and read by a healthcare provider empowered to treat the patient or to make an appropriate referral. Automated preoperative alerts alone are not likely to alter surgeons' anemia management practices. These alerts need to be part of a comprehensive anemia management strategy.

  5. Experimental evaluation of candidate graphical microburst alert displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig; Hansman, R. John

    1992-01-01

    The topics addressed are: (1) experimental evaluation of candidate graphical microburst displays; (2) microburst detection and alerting; (3) previous part-task simulator experiment-comparison of presentation modes; (4) presentation mode comparison-results; (5) advantages of graphical mode of presentation; (6) graphical microburst alert experiment-objectives; and graphical microburst alert experiment-overview; and (7) candidate display design.

  6. Effect of Epoxy on Mechanical Property of SAC305 Solder Joint with Various Surface Finishes Under 3-Point Bend Test.

    PubMed

    Jeong, Haksan; Myung, Woo-Ram; Sung, Yong-Gue; Kim, Kyung-Yeol; Jung, Seung-Boo

    2018-09-01

    Microstructures and mechanical property of Sn-3.0Ag-0.5Cu (SAC305) and epoxy Sn-3.0Ag-0.5Cu (epoxy SAC) solder joints were investigated with various surface finishes; organic solderability preservative (OSP), electroless nickel immersion gold (ENIG) and electroless nickel electroless palladium immersion gold (ENEPIG). Bending property of solder joints was evaluated by 3-point bend test method. Microstructure and chemical composition of solder joints was characterized by scanning electron microscope (SEM) and energy dispersive X-ray spectroscopy (EDX), respectively. Epoxy did not effect on intermetallic compound (IMC) morphology. Scalloped shaped Cu6Sn5 IMC was observed at OSP surface finish. Chunky-like shaped and needle-like shaped (Ni,Cu)6Sn5 IMC were observed at the solder/ENIG joint and solder/ENEPIG joint, respectively. The bending cycles of SAC305/OSP joint, SAC305/ENIG joints and SAC305/ENEPIG joints were 720, 440 and 481 cycle numbers. The bending cycles of epoxy SAC and three types surface finished solder joints were over 1000 bending cycles. Under OSP surface finish, bending cycles of epoxy SAC solder was approximately 1.5 times higher than those of SAC305 solder joint. Bending cycles of epoxy SAC solder was over twice times higher than those of SAC305 solder with ENIG and ENEPIG surface finishes. The bending property of epoxy solder joint was enhanced due to epoxy fillet held the solder joint.

  7. Subjective alertness rhythms in elderly people

    NASA Technical Reports Server (NTRS)

    Monk, T. H.; Buysse, D. J.; Reynolds, C. F. 3rd; Kupfer, D. J.; Houck, P. R.

    1996-01-01

    The aim of this study was to evaluate age-related changes in the circadian rhythm of subjective alertness and to explore the circadian mechanisms underlying such changes. Using a visual analogue scale (VAS) instrument, 25 older men and women (71 y and older; 15 female, 10 male) rated their subjective alertness about 7 times per day during 5 baseline days of temporal isolation during which habitual bedtimes and waketimes were enforced. Comparisons were made with 13 middle-aged men (37-52 y) experiencing the same protocol. Advancing age (particularly in the men) resulted in less rhythmic alertness patterns, as indicated by lower amplitudes and less reliability of fitted 24-h sinusoids. This appeared in spite of the absence of any reliable age-related diminution in circadian temperature rhythm amplitude, thus suggesting the effect was not due to SCN weakness per se, but to weakened transduction of SCN output. In a further experiment, involving 36 h of constant wakeful bedrest, differences in the amplitude of the alertness rhythm were observed between 9 older men (79 y+), 7 older women (79 y+), and 17 young controls (9 males, 8 females, 19-28 y) suggesting that with advancing age (particularly in men) there is less rhythmic input into subjective alertness from the endogenous circadian pacemaker. These results may explain some of the nocturnal insomnia and daytime hypersomnia that afflict many elderly people.

  8. Surgery of metastatic anal sac adenocarcinoma in five dogs.

    PubMed

    Hobson, Howard Phil; Brown, Marjorie Raquel; Rogers, Kenita S

    2006-04-01

    To identify survival and morbidity information after surgery for metastases from apocrine gland anal sac adenocarcinomas (AGACA). Retrospective study. Five dogs with AGACA. Medical records of dogs that had surgery for treatment of metastatic AGACA between 1993 and 2003 were reviewed. Criteria for inclusion required that dogs had lymphadenectomy, with or without further debulking, as part of their treatment for metastatic AGACA and that the tissue was histologically confirmed as consistent with the primary AGACA. Signalment, history, physical examination findings, clinicopathologic data, imaging findings, surgical complications, number of surgeries, survival times, and cause of death were recorded. All dogs had a complete blood count, serum biochemical profile, serum electrolytes, 3-projection thoracic radiographs, abdominal radiographs and/or abdominal ultrasonography, and histologic confirmation of metastatic AGACA invading the regional lymph nodes and caudal abdomen. No surgical complications occurred. Three dogs were euthanatized; median survival, 20.6 months. One dog was alive for 19 months postoperatively. One dog had 5 sequential surgical procedures: 1 iliac lymphadenectomy and 4 debulking procedures of metastatic neoplastic tissue around and dorsal to the iliac vessels extending into the pelvic cavity, and was alive 54 months after initial surgery. Dogs with anal sac adenocarcinoma metastases to the iliac lymph nodes can experience long-term survival after surgical excision of the metastatic lesion. Lymphadenectomy may afford long-term survival to patients with metastatic anal sac adenocarcinoma.

  9. Combining anti-cancer drugs with artificial sweeteners: synthesis and anti-cancer activity of saccharinate (sac) and thiosaccharinate (tsac) complexes cis-[Pt(sac)2(NH3)2] and cis-[Pt(tsac)2(NH3)2].

    PubMed

    Al-Jibori, Subhi A; Al-Jibori, Ghassan H; Al-Hayaly, Lamaan J; Wagner, Christoph; Schmidt, Harry; Timur, Suna; Baris Barlas, F; Subasi, Elif; Ghosh, Shishir; Hogarth, Graeme

    2014-12-01

    The new platinum(II) complexes cis-[Pt(sac)2(NH3)2] (sac=saccharinate) and cis-[Pt(tsac)2(NH3)2] (tsac=thiosaccharinate) have been prepared, the X-ray crystal structure of cis-[Pt(sac)2(NH3)2] x H2O reveals that both saccharinate anions are N-bound in a cis-arrangement being inequivalent in both the solid-state and in solution at room temperature. Preliminary anti-cancer activity has been assessed against A549 human alveolar type-II like cell lines with the thiosaccharinate complex showing good activity. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. P63 Positive Mucoepidermoid Tumor of the Lacrimal Sac with Associated Papilloma.

    PubMed

    Iordanous, Yiannis; Belrose, Jillian C; Cadieux, Dani C; Chakrabarti, Subrata; Farmer, James P; Allen, Larry H

    2015-01-01

    We report a case of a 44-year-old man who presented with a left medial canthal mass and epiphora. Imaging was suggestive of a mass continuous with the nasolacrimal sac. Subsequent surgical exploration revealed a mass adherent to bone with invasion of the lacrimal system. Histological examination revealed a squamous/transitional cell papilloma overlying a low-grade mucoepidermoid carcinoma (MEC). Complete surgical resection was completed and pathology confirmed the diagnosis. This is the first case in which a MEC has been reported concurrently with an overlying papilloma, providing support for the hypothesis that MECs arise from papillomas in the lacrimal sac. Additionally, the tissue stained positive for p63, which is congruent with MEC immunoreactivity in the salivary gland. The description of these unique histopathological findings may assist in definitive diagnosis and improve our understanding of the pathophysiology underlying lacrimal sac MEC tumors.

  11. The NAS Alert System: A look at the first eight years

    USGS Publications Warehouse

    Fuller, Pamela L.; Neilson, Matt; Huge, Dane H.

    2013-01-01

    The U.S. Geological Survey's Nonindigenous Aquatic Species (NAS) database program (http://nas.er.usgs.gov) tracks the distribution of introduced aquatic organisms across the United States. Awareness of, and timely response to, novel species introductions by those involved in nonindigenous aquatic species management and research requires a framework for rapid dissemination of occurrence data as it is incorporated into the NAS database. In May 2004, the NAS program developed an alert system to notify registered users of new introductions as part of a national early detection/rapid response system. This article summarizes information on system users and dispatched alerts from the system's inception through the end of 2011. The NAS alert system has registered over 1,700 users, with approximately 800 current subscribers. A total of 1,189 alerts had been transmitted through 2011. More alerts were sent for Florida (134 alerts) than for any other state. Fishes comprise the largest taxonomic group of alerts (440), with mollusks, plants, and crustaceans each containing over 100 alerts. Most alerts were for organisms that were intentionally released (414 alerts), with shipping, escape from captivity, and hitchhiking also representing major vectors. To explore the archive of sent alerts and to register, the search and signup page for the alert system can be found online at http://nas.er.usgs.gov/AlertSystem/default.aspx.

  12. Increased appropriateness of customized alert acknowledgement reasons for overridden medication alerts in a computerized provider order entry system.

    PubMed

    Dekarske, Brian M; Zimmerman, Christopher R; Chang, Robert; Grant, Paul J; Chaffee, Bruce W

    2015-12-01

    Computerized provider order entry systems commonly contain alerting mechanisms for patient allergies, incorrect doses, or drug-drug interactions when ordering medications. Providers have the option to override (bypass) these alerts and continue with the order unchanged. This study examines the effect of customizing medication alert override options on the appropriateness of override selection related to patient allergies, drug dosing, and drug-drug interactions when ordering medications in an electronic medical record. In this prospective, randomized crossover study, providers were randomized into cohorts that required a reason for overriding a medication alert from a customized or non-customized list of override reasons and/or by free-text entry. The primary outcome was to compare override responses that appropriately correlate with the alert type between the customized and non-customized configurations. The appropriateness of a subset of free-text responses that represented an affirmative and active acknowledgement of the alert without further explanation was classified as "indeterminate." Results were analyzed in three different ways by classifying indeterminate answers as either appropriate, inappropriate, or excluded entirely. Secondary outcomes included the appropriateness of override reasons when comparing cohorts and individual providers, reason selection based on order within the override list, and the determination of the frequency of free-text use, nonsensical responses, and multiple selection responses. Twenty-two clinicians were randomized into 2 cohorts and a total of 1829 alerts with a required response were generated during the study period. The customized configuration had a higher rate of appropriateness when compared to the non-customized configuration regardless of how indeterminate responses were classified (p<0.001). When comparing cohorts, appropriateness was significantly higher in the customized configuration regardless of the

  13. Provider acceptance of an automated electronic alert for acute kidney injury

    PubMed Central

    Oh, Janice; Bia, Joshua R.; Ubaid-Ullah, Muhamad; Testani, Jeffrey M.; Wilson, Francis Perry

    2016-01-01

    Background Clinical decision support systems, including electronic alerts, ideally provide immediate and relevant patient-specific information to improve clinical decision-making. Despite the growing capabilities of such alerts in conjunction with an expanding electronic medical record, there is a paucity of information regarding their perceived usefulness. We surveyed healthcare providers' opinions concerning the practicality and efficacy of a specific text-based automated electronic alert for acute kidney injury (AKI) in a single hospital during a randomized trial of AKI alerts. Methods Providers who had received at least one electronic AKI alert in the previous 6 months, as part of a separate randomized controlled trial (clinicaltrials.gov #01862419), were asked to complete a survey concerning their opinions about this specific AKI alert system. Individual approval of the alert system was defined by a provider's desire to continue receiving the alert after termination of the trial. Results A total of 98 individuals completed the survey, including 62 physicians, 27 pharmacists and 7 non-physician providers. Sixty-nine percent of responders approved the alert, with no significant difference among the various professions (P = 0.28). Alert approval was strongly correlated with the belief that the alerts improved patient care (P < 0.0001), and negatively correlated with the belief that alerts did not provide novel information (P = 0.0001). With each additional 30 days of trial duration, odds of approval decreased by 20% (3–35%) (P = 0.02). Conclusions The alert system was generally well received, although approval waned with time. Approval was correlated with the belief that this type of alert improved patient care. These findings suggest that perceived efficacy is critical to the success of future alert trials. PMID:27478598

  14. [Health alert management and emerging risk].

    PubMed

    Pillonel, J

    2010-12-01

    Following health crisis that have occurred in the nineties (contaminated blood, mad cow, asbestos, etc.) and more recently those generated by the heat wave in 2003 or by emerging infectious pathogens (SARS, West Nile, Chikungunya, H5N1, H1N1…), a real health vigilance system has been progressively developed in France. After a brief historical overview of the health alert system, this article will give the guiding principles of its current organization in France and will present two examples of recent health alerts (Chikungunya in the Reunion Island in 2005-2006 and hepatitis A outbreak in the Côtes-d'Armor in August 2007), that have needed the implementation of preventive measures regarding the blood donor selection. These two examples have shown that the position of the alert in the French health vigilance system needs to be very close to the event. In that case, health alert is a very useful tool for decision making especially when measures have to be taken to prevent transfusion-transmitted pathogens. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  15. Geo-targeted Weather Alerts Coming to Millions of Mobile Devices

    NASA Astrophysics Data System (ADS)

    Gerber, M.

    2011-12-01

    The Personal Localized Alert Network (PLAN), aka Commercial Mobile Alert System (CMAS), is readying for roll out and will be broadcasting emergency public alerts to millions of cell phones by the middle of 2012. Learn how the National Weather Serivce (NWS) is supplying PLAN with geo-referenced weather alert information in the industry standard Common Alerting Protocol (CAP) format and how you can access this same information for integration with mobile devices, other consumer electronics, and decision support systems. Information will also be provided on the NWS' new collaborative venue that encourages wide participation in the evolution and use of NWS CAP alerts in a variety of applications.

  16. Radar-based alert system to operate a sewerage network: relevance and operational effectiveness after several years of use.

    PubMed

    Faure, D; Payrastre, O; Auchet, P

    2005-01-01

    Since January 2000, the sewerage network of a very urbanised catchment area in the Greater Nancy Urban Community has been operated according to the alarms generated in real time by a storm alert system using weather radar data. This alert system is based on an automatic identification of intense rain cells in the radar images. This paper presents the characteristics of this alert system and synthesises the main results of two complementary studies realised in 2002 in order to estimate the relevance and the operational effectiveness of the alert system. The first study consisted in an off-line analysis of almost 50,000 intense rain cells detected in four years of historical radar data. The second study was an analysis of the experience feedback after two years of operational use of this alert system. The results of these studies are discussed in function of the initial operational objectives.

  17. Anisotropic shrinkage of insect air sacs revealed in vivo by X-ray microtomography

    NASA Astrophysics Data System (ADS)

    Xu, Liang; Chen, Rongchang; Du, Guohao; Yang, Yiming; Wang, Feixiang; Deng, Biao; Xie, Honglan; Xiao, Tiqiao

    2016-09-01

    Air sacs are thought to be the bellows for insect respiration. However, their exact mechanism of action as a bellows remains unclear. A direct way to investigate this problem is in vivo observation of the changes in their three-dimensional structures. Therefore, four-dimensional X-ray phase contrast microtomography is employed to solve this puzzle. Quantitative analysis of three-dimensional image series reveals that the compression of the air sac during respiration in bell crickets exhibits obvious anisotropic characteristics both longitudinally and transversely. Volumetric changes of the tracheal trunks in the prothorax further strengthen the evidence of this finding. As a result, we conclude that the shrinkage and expansion of the insect air sac is anisotropic, contrary to the hypothesis of isotropy, thereby providing new knowledge for further research on the insect respiratory system.

  18. sAC as a model for understanding the impact of endosymbiosis on cell signaling.

    PubMed

    Blackstone, Neil W

    2014-12-01

    As signaling pathways evolve, selection for new functions guides the co-option of existing material. Major transitions in the history of life, including the evolution of eukaryotes and multicellularity, exemplify this process. These transitions provided both strong selection and a plenitude of available material for the evolution of signaling pathways. Mechanisms that evolved to mediate conflict during the evolution of eukaryotes may subsequently have been co-opted during the many independent derivations of multicellularity. The soluble adenylyl cyclase (sAC) signaling pathway illustrates this hypothesis. Class III adenylyl cyclases, which include sAC, are found in bacteria, including the α-proteobacteria. These adenylyl cyclases are the only ones present in eukaryotes but appear to be absent in archaeans. This pattern suggests that the mitochondrial endosymbiosis brought sAC signaling to eukaryotes as part of an intact module. After transfer to the proto-nuclear genome, this module was then co-opted into numerous new functions. In the evolution of eukaryotes, sAC signaling may have mediated conflicts by maintaining metabolic homeostasis. In the evolution of multicellularity, in different lineages sAC may have been co-opted into parallel tasks originally related to conflict mediation. Elucidating the history of the sAC pathway may be relatively straightforward because it is ubiquitous and linked to near universal metabolic by-products (CO₂/HCO(3)(-)). Other signaling pathways (e.g., those involving STAT and VEGF) present a greater challenge but may suggest a complementary pattern. The impact of the mitochondrial endosymbiosis on cell signaling may thus have been profound. This article is part of a Special Issue entitled: The role of soluble adenylyl cyclase in health and disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Novel homozygous variants in ATCAY, MCOLN1, and SACS in complex neurological disorders.

    PubMed

    Manzoor, Humera; Brüggemann, Norbert; Hussain, Hafiz Muhammad Jafar; Bäumer, Tobias; Hinrichs, Frauke; Wajid, Muhammad; Münchau, Alexander; Naz, Sadaf; Lohmann, Katja

    2018-06-01

    Neurological disorders comprise a large group of clinically and genetically heterogeneous disorders, many of which have a genetic cause. In addition to a detailed neurological examination, exome sequencing is being increasingly used as a complementary diagnostic tool to identify the underlying genetic cause in patients with unclear, supposedly genetically determined disorders. To identify the genetic cause of a complex movement disorder in five consanguineous Pakistani families. We included five consanguineous Pakistani families with complex recessively inherited movement disorders. Clinical investigation including videotaping was carried out in a total of 59 family members (4-21 per family) and MRI in six patients. Exome sequencing was performed in 4-5 family members per pedigree to explore the underlying genetic cause. Patients presented a wide spectrum of neurological symptoms including ataxia and/or dystonia. We identified three novel homozygous, segregating variants in ATCAY (p.Pro200Profs*20), MCOLN1 (p.Ile184Thr), and SACS (p.Asn3040Lysfs*4) in three of the families. Thus, we were able to identify the likely cause of the disease in a considerable number of families (60%) with the relatively simple and nowadays widely available method of exome sequencing. Of note, close collaboration of neurologists and geneticists was instrumental for proper data interpretation. We expand the phenotypic, genotypic, and ethnical spectrum of mutations in these genes. Our findings alert neurologists that rare genetic causes should be considered in complex phenotypes regardless of ethnicity. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Computing and Engineering in Afterschool. Afterschool Alert. Issue Brief No. 62

    ERIC Educational Resources Information Center

    Afterschool Alliance, 2013

    2013-01-01

    This Afterschool Alert Issue Brief explores how afterschool programs are offering innovative, hands-on computing and engineering education opportunities. Both these subjects have emerged as priority areas within the "STEM" fields. Computing is one of the fastest growing industries, and yet current rates of college graduation in computer…

  1. 77 FR 26701 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Federal Communications Commission (Commission) amends its rules governing the Emergency Alert... the manner in which EAS Participants must be able to receive alert messages formatted in the Common...

  2. Computerized Alerts Improve Outpatient Laboratory Monitoring of Transplant Patients

    PubMed Central

    Staes, Catherine J.; Evans, R. Scott; Rocha, Beatriz H.S.C.; Sorensen, John B.; Huff, Stanley M.; Arata, Joan; Narus, Scott P.

    2008-01-01

    Authors evaluated the impact of computerized alerts on the quality of outpatient laboratory monitoring for transplant patients. For 356 outpatient liver transplant patients managed at LDS Hospital, Salt Lake City, this observational study compared traditional laboratory result reporting, using faxes and printouts, to computerized alerts implemented in 2004. Study alerts within the electronic health record notified clinicians of new results and overdue new orders for creatinine tests and immunosuppression drug levels. After implementing alerts, completeness of reporting increased from 66 to >99 %, as did positive predictive value that a report included new information (from 46 to >99 %). Timeliness of reporting and clinicians' responses improved after implementing alerts (p <0.001): median times for clinicians to receive and complete actions decreased to 9 hours from 33 hours using the prior traditional reporting system. Computerized alerts led to more efficient, complete, and timely management of laboratory information. PMID:18308982

  3. Prototype Conflict Alerting Logic for Free Flight

    NASA Technical Reports Server (NTRS)

    Yang, Lee C.; Kuchar, James K.

    1997-01-01

    This paper discusses the development of a prototype alerting system for a conceptual Free Flight environment. The concept assumes that datalink between aircraft is available and that conflicts are primarily resolved on the flight deck. Four alert stages are generated depending on the likelihood of a conflict. If the conflict is not resolved by the flight crews, Air Traffic Control is notified to take over separation authority. The alerting logic is based on probabilistic analysis through modeling of aircraft sensor and trajectory uncertainties. Monte Carlo simulations were used over a range of encounter situations to determine conflict probability. The four alert stages were then defined based on probability of conflict and on the number of avoidance maneuvers available to the flight crew. Preliminary results from numerical evaluations and from a piloted simulator study at NASA Ames Research Center are summarized.

  4. Participatory design for drug-drug interaction alerts.

    PubMed

    Luna, Daniel; Otero, Carlos; Almerares, Alfredo; Stanziola, Enrique; Risk, Marcelo; González Bernaldo de Quirós, Fernán

    2015-01-01

    The utilization of decision support systems, in the point of care, to alert drug-drug interactions has been shown to improve quality of care. Still, the use of these systems has not been as expected, it is believed, because of the difficulties in their knowledge databases; errors in the generation of the alerts and the lack of a suitable design. This study expands on the development of alerts using participatory design techniques based on user centered design process. This work was undertaken in three stages (inquiry, participatory design and usability testing) it showed that the use of these techniques improves satisfaction, effectiveness and efficiency in an alert system for drug-drug interactions, a fact that was evident in specific situations such as the decrease of errors to meet the specified task, the time, the workload optimization and users overall satisfaction in the system.

  5. 78 FR 22270 - Special Fraud Alert: Physician-Owned Entities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-15

    ...] Special Fraud Alert: Physician-Owned Entities AGENCY: Office of Inspector General (OIG), HHS. ACTION... Physician-Owned Entities. Specifically, the Special Fraud Alert addressed physician-owned entities that... publication of the Special Fraud Alert on Physician-Owned Entities, an inadvertent error appeared in the DATES...

  6. 77 FR 33661 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-07

    ... Emergency Alert System AGENCY: Federal Communications Commission. ACTION: Final rule; announcement of... Commission's Review of the Emergency Alert System, Fifth Report and Order (Order). This document is... Expiration Date: November 30, 2012. Title: Part 11--Emergency Alert System, Fifth Report and Order, FCC 12-7...

  7. The Internet Alert Project: spreading the word about high-risk sexual activities advertised on the Internet.

    PubMed

    Kachur, R E

    2004-11-01

    The Internet is an emerging venue for facilitating high-risk sexual behavior; in particular, use of the Internet to seek out sex partners has been shown to be associated with high-risk sexual behaviors, such as an increase in number of sexual partners and an increase in anal sex, which can increase the risk of contracting and transmitting sexually transmitted diseases (STDs) including HIV. In an effort to assist health departments around the country, the Internet Alert Project was developed to provide Centers for Disease Control and Prevention (CDC) project officers and field staff with information about Internet-advertised, high-risk sexual activities in areas that do not have access to sexually explicit material on the Internet. An evaluation was conducted to determine the utility of the Internet Alert Project, its effect on knowledge and awareness of recipients and on public health efforts. Results of the evaluation show the alerts are a useful and valuable tool. The alerts have helped to increase knowledge about sexually-related uses of the Internet and have also driven public health efforts in the field. The results also indicate the need for project areas to access information found on the Internet in order to keep up with the ever-changing behaviors of at-risk populations.

  8. Building a Communication, Education, an Outreach Program for the ShakeAlert National Earthquake Early Warning Program - Recommendations for Public Alerts Via Cell Phones

    NASA Astrophysics Data System (ADS)

    DeGroot, R. M.; Long, K.; Strauss, J. A.

    2017-12-01

    The United States Geological Survey (USGS) and its partners are developing the ShakeAlert Earthquake Early Warning System for the West Coast of the United States. To be an integral part of successful implementation, ShakeAlert engagement programs and materials must integrate with and leverage broader earthquake risk programs. New methods and products for dissemination must be multidisciplinary, cost effective, and consistent with existing hazards education and communication efforts. The ShakeAlert Joint Committee for Communication, Education, and Outreach (JCCEO), is identifying, developing, and cultivating partnerships with ShakeAlert stakeholders including Federal, State, academic partners, private companies, policy makers, and local organizations. Efforts include developing materials, methods for delivery, and reaching stakeholders with information on ShakeAlert, earthquake preparedness, and emergency protective actions. It is essential to develop standards to ensure information communicated via the alerts is consistent across the public and private sector and achieving a common understanding of what actions users take when they receive a ShakeAlert warning. In February 2017, the JCCEO convened the Warning Message Focus Group (WMFG) to provide findings and recommendations to the Alliance for Telecommunications Industry Solutions on the use of earthquake early warning message content standards for public alerts via cell phones. The WMFG represents communications, education, and outreach stakeholders from various sectors including ShakeAlert regional coordinators, industry, emergency managers, and subject matter experts from the social sciences. The group knowledge was combined with an in-depth literature review to ensure that all groups who could receive the message would be taken into account. The USGS and the participating states and agencies acknowledge that the implementation of ShakeAlert is a collective effort requiring the participation of hundreds of

  9. 48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...

  10. 48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...

  11. 48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...

  12. 48 CFR 301.603-74 - Requirement for retention of FAC-C and HHS SAC certification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of FAC-C and HHS SAC certification. 301.603-74 Section 301.603-74 Federal Acquisition Regulations..., Contracting Authority, and Responsibilities 301.603-74 Requirement for retention of FAC-C and HHS SAC certification. To maintain FAC-C certification, all warranted Contracting Officers, regardless of series, as...

  13. Development of the inverted visceral yolk sac in three species of caviids (Rodentia, Caviomorpha, Caviidae).

    PubMed

    Miglino, M A; Franciolli, A L R; de Oliveira, M F; Ambrósio, C E; Bonatelli, M; Machado, M R F; Mess, A

    2008-08-01

    Guinea pig related rodents possess numerous derived placental characters. We attempt to identify diversity within the visceral yolk sac and its association with the chorioallantoic placenta in three species of caviids, two of them possessing a capsule formed by the decidua that covers the chorioallantoic placenta. The results verify that in early pregnancy all three species have an inverted yolk sac placenta. In advanced pregnancy the species differ: Galea spixii, as representative without a capsule, bear a yolk sac in apposition to the chorioallantoic placenta with signs of exchange activity until term. Galea is similar to other caviomorphs in this respect. In Dasyprocta leporina and Cuniculus paca, the representatives possessing a capsule, the yolk sac endoderm lacks signs of substance exchange. Evidently, the presence of a capsule prevents such an interaction. The variations established here must be considered if animal models for human placentation are required which have restricted access to the chorioallantoic placenta from the outside.

  14. A Novel Design for Drug-Drug Interaction Alerts Improves Prescribing Efficiency.

    PubMed

    Russ, Alissa L; Chen, Siying; Melton, Brittany L; Johnson, Elizabette G; Spina, Jeffrey R; Weiner, Michael; Zillich, Alan J

    2015-09-01

    Drug-drug interactions (DDIs) are common in clinical care and pose serious risks for patients. Electronic health records display DDI alerts that can influence prescribers, but the interface design of DDI alerts has largely been unstudied. In this study, the objective was to apply human factors engineering principles to alert design. It was hypothesized that redesigned DDI alerts would significantly improve prescribers' efficiency and reduce prescribing errors. In a counterbalanced, crossover study with prescribers, two DDI alert designs were evaluated. Department of Veterans Affairs (VA) prescribers were video recorded as they completed fictitious patient scenarios, which included DDI alerts of varying severity. Efficiency was measured from time-stamped recordings. Prescribing errors were evaluated against predefined criteria. Efficiency and prescribing errors were analyzed with the Wilcoxon signed-rank test. Other usability data were collected on the adequacy of alert content, prescribers' use of the DDI monograph, and alert navigation. Twenty prescribers completed patient scenarios for both designs. Prescribers resolved redesigned alerts in about half the time (redesign: 52 seconds versus original design: 97 seconds; p<.001). Prescribing errors were not significantly different between the two designs. Usability results indicate that DDI alerts might be enhanced by facilitating easier access to laboratory data and dosing information and by allowing prescribers to cancel either interacting medication directly from the alert. Results also suggest that neither design provided adequate information for decision making via the primary interface. Applying human factors principles to DDI alerts improved overall efficiency. Aspects of DDI alert design that could be further enhanced prior to implementation were also identified.

  15. Penguin lungs and air sacs: implications for baroprotection, oxygen stores and buoyancy.

    PubMed

    Ponganis, P J; St Leger, J; Scadeng, M

    2015-03-01

    The anatomy and volume of the penguin respiratory system contribute significantly to pulmonary baroprotection, the body O2 store, buoyancy and hence the overall diving physiology of penguins. Therefore, three-dimensional reconstructions from computerized tomographic (CT) scans of live penguins were utilized to measure lung volumes, air sac volumes, tracheobronchial volumes and total body volumes at different inflation pressures in three species with different dive capacities [Adélie (Pygoscelis adeliae), king (Aptenodytes patagonicus) and emperor (A. forsteri) penguins]. Lung volumes scaled to body mass according to published avian allometrics. Air sac volumes at 30 cm H2O (2.94 kPa) inflation pressure, the assumed maximum volume possible prior to deep dives, were two to three times allometric air sac predictions and also two to three times previously determined end-of-dive total air volumes. Although it is unknown whether penguins inhale to such high volumes prior to dives, these values were supported by (a) body density/buoyancy calculations, (b) prior air volume measurements in free-diving ducks and (c) previous suggestions that penguins may exhale air prior to the final portions of deep dives. Based upon air capillary volumes, parabronchial volumes and tracheobronchial volumes estimated from the measured lung/airway volumes and the only available morphometry study of a penguin lung, the presumed maximum air sac volumes resulted in air sac volume to air capillary/parabronchial/tracheobronchial volume ratios that were not large enough to prevent barotrauma to the non-collapsing, rigid air capillaries during the deepest dives of all three species, and during many routine dives of king and emperor penguins. We conclude that volume reduction of airways and lung air spaces, via compression, constriction or blood engorgement, must occur to provide pulmonary baroprotection at depth. It is also possible that relative air capillary and parabronchial volumes are

  16. Laparoscopic repair of hernia in children: Comparison between ligation and nonligation of sac.

    PubMed

    Pant, Nitin; Aggarwal, Satish Kumar; Ratan, Simmi K

    2014-04-01

    The essence of the current techniques of laparoscopic hernia repair in children is suture ligation of the neck of the hernia sac at the deep ring with or without its transection. Some studies show that during open hernia repair, after transection at the neck it can be left unsutured without any consequence. This study was aimed to see if the same holds true for laparoscopic hernia repair. Sixty patients (52 boys and eight girls, 12-144 months) with indirect inguinal hernia were randomized for laparoscopic repair either by transection of the sac alone (Group I) or transection plus suture ligation of sac at the neck (Group II). Outcome was assessed in terms of time taken for surgery, recurrence, and other complications. Thirty-eight hernia units in 28 patients were repaired by transection alone (Group I) and 34 hernia units in 29 patients were repaired by transection and suture ligation (Group II). Three patients were found to have no hernia on laparoscopy. Recurrence rate and other complications were not significantly different in the two groups. All recurrences occurred in hernias with ring size more than 10 mm. Laparoscopic repair of hernia by circumferential incision of the peritoneum at the deep ring is as effective as incision plus ligation of the sac.

  17. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  18. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  19. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  20. 47 CFR 80.277 - Ship Security Alert System (SSAS).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Ship Security Alert System (SSAS). 80.277... SERVICES STATIONS IN THE MARITIME SERVICES Equipment Authorization for Compulsory Ships § 80.277 Ship Security Alert System (SSAS). (a) Vessels equipped with a Ship Security Alert System pursuant to the Safety...

  1. Environmental Assessment for Demolition of SAC Alert Facility

    DTIC Science & Technology

    2008-05-01

    the installation and may improve the quality of storm water leaving the installation. No negative impact to storm water quality is anticipated...and drainage and storm water quality would be anticipated to Improve. Implementing the proposed action would have the potential to impact surface

  2. Provider management strategies of abnormal test result alerts: a cognitive task analysis.

    PubMed

    Hysong, Sylvia J; Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Electronic medical records (EMRs) facilitate abnormal test result communication through "alert" notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results.

  3. Ovarian mixed germ cell tumor with yolk sac and teratomatous components in a dog.

    PubMed

    Robinson, Nicholas A; Manivel, J Carlos; Olson, Erik J

    2013-05-01

    Mixed germ cell tumors of the ovary have rarely been reported in veterinary species. A 3-year-old intact female Labrador Retriever dog was presented for lethargy, abdominal distention, and a midabdominal mass. An exploratory laparotomy revealed a large (23 cm in diameter) left ovarian tumor and multiple small (2-3 cm in diameter) pale tan masses on the peritoneum and abdominal surface of the diaphragm. Histological examination of the left ovary revealed a mixed germ cell tumor with a yolk sac component with rare Schiller-Duval bodies and a teratomatous component comprised primarily of neural differentiation. The abdominal metastases were solely comprised of the yolk sac component. The yolk sac component was diffusely immunopositive for cytokeratin with scattered cells reactive for α-fetoprotein and placental alkaline phosphatase. Within the teratomatous component, the neuropil was diffusely immunopositive for S100, neuron-specific enolase, and neurofilaments with a few glial fibrillary acidic protein immunopositive cells. Ovarian germ cell tumors may be pure and consist of only 1 germ cell element or may be mixed and include more than 1 germ cell element, such as teratoma and yolk sac tumor.

  4. Modeling, Analyzing, and Mitigating Dissonance Between Alerting Systems

    NASA Technical Reports Server (NTRS)

    Song, Lixia; Kuchar, James K.

    2003-01-01

    Alerting systems are becoming pervasive in process operations, which may result in the potential for dissonance or conflict in information from different alerting systems that suggests different threat levels and/or actions to resolve hazards. Little is currently available to help in predicting or solving the dissonance problem. This thesis presents a methodology to model and analyze dissonance between alerting systems, providing both a theoretical foundation for understanding dissonance and a practical basis from which specific problems can be addressed. A state-space representation of multiple alerting system operation is generalized that can be tailored across a variety of applications. Based on the representation, two major causes of dissonance are identified: logic differences and sensor error. Additionally, several possible types of dissonance are identified. A mathematical analysis method is developed to identify the conditions for dissonance originating from logic differences. A probabilistic analysis methodology is developed to estimate the probability of dissonance originating from sensor error, and to compare the relative contribution to dissonance of sensor error against the contribution from logic differences. A hybrid model, which describes the dynamic behavior of the process with multiple alerting systems, is developed to identify dangerous dissonance space, from which the process can lead to disaster. Methodologies to avoid or mitigate dissonance are outlined. Two examples are used to demonstrate the application of the methodology. First, a conceptual In-Trail Spacing example is presented. The methodology is applied to identify the conditions for possible dissonance, to identify relative contribution of logic difference and sensor error, and to identify dangerous dissonance space. Several proposed mitigation methods are demonstrated in this example. In the second example, the methodology is applied to address the dissonance problem between two air

  5. In vitro analysis of type II endoleaks and aneurysm sac pressurization on longitudinal stent-graft displacement.

    PubMed

    Knowles, Martyn; Pellisar, Tiago; Murphy, Erin H; Stanley, Gregory A; Hashmi, Abraham F; Arko, M Zachary; Arko, Frank R

    2011-08-01

    To evaluate the effects of type II endoleaks and sac pressurization on stent-graft displacement following endovascular aneurysm repair (EVAR). Experimental silicone infrarenal aneurysm (6-cm) models were "treated" with a Talent stent-graft deployed with 20-mm proximal and distal landing zones. Inflow and outflow vessels were created as part of the silicone model to control flow into the aneurysm sac. All aneurysm models were uniform, with a diameter neck of 31 mm, a neck length of 20 mm, and iliac artery diameters of 16 mm. The aortic model was secured in a water bath to a pulsatile pump under physiological conditions; the output phase ratio (%systole/%diastole) was set at 65/35 with a pump rate of 80 beats per minute. Commercially available bifurcated stent-grafts were then displaced in vitro utilizing a linear motion apparatus attached to a force gauge. The mean arterial pressure (MAP) and pulse pressure (PP) at the aortic inflow were 60.1 ± 3.1 and 38.3 ± 7.8 mmHg, respectively. Peak force to cause initial stent-graft migration with and without a type II endoleak was recorded and compared. In aneurysm sacs with no endoleak, the MAP and sac PP were 32 ± 6.4 and 6 ± 1.3 mmHg, respectively (p<0.01). In aneurysm sacs with a type II endoleak, the MAP and sac PP were 54.1 ± 9.7 and 16.1 ± 4.1 mmHg, respectively (p<0.02). Peak force to initiate migration was 16.0 ± 1.41 N (range 15-18) with no endoleak vs. 23.2 ± 2.2 N (range 20-25) in those with a type IIa endoleak and 23.5 ± 2.5 N (range 20-26) in those with a type IIb endoleak (p<0.001). Type II endoleaks are associated with a significantly increased sac pressure. Increased sac pressurization from type II endoleaks results in a significantly greater force to displace a stent-graft longitudinally. Type II endoleaks may therefore inhibit migration and offer a benefit following EVAR; however, clinical correlation of these results is required.

  6. Modeling Pilot State in Next Generation Aircraft Alert Systems

    NASA Technical Reports Server (NTRS)

    Carlin, Alan S.; Alexander, Amy L.; Schurr, Nathan

    2011-01-01

    The Next Generation Air Transportation System will introduce new, advanced sensor technologies into the cockpit that must convey a large number of potentially complex alerts. Our work focuses on the challenges associated with prioritizing aircraft sensor alerts in a quick and efficient manner, essentially determining when and how to alert the pilot This "alert decision" becomes very difficult in NextGen due to the following challenges: 1) the increasing number of potential hazards, 2) the uncertainty associated with the state of potential hazards as well as pilot slate , and 3) the limited time to make safely-critical decisions. In this paper, we focus on pilot state and present a model for anticipating duration and quality of pilot behavior, for use in a larger system which issues aircraft alerts. We estimate pilot workload, which we model as being dependent on factors including mental effort, task demands. and task performance. We perform a mathematically rigorous analysis of the model and resulting alerting plans. We simulate the model in software and present simulated results with respect to manipulation of the pilot measures.

  7. Evaluation of Antimicrobial Stewardship-Related Alerts Using a Clinical Decision Support System.

    PubMed

    Ghamrawi, Riane J; Kantorovich, Alexander; Bauer, Seth R; Pallotta, Andrea M; Sekeres, Jennifer K; Gordon, Steven M; Neuner, Elizabeth A

    2017-11-01

    Background: Information technology, including clinical decision support systems (CDSS), have an increasingly important and growing role in identifying opportunities for antimicrobial stewardship-related interventions. Objective: The aim of this study was to describe and compare types and outcomes of CDSS-built antimicrobial stewardship alerts. Methods: Fifteen alerts were evaluated in the initial antimicrobial stewardship program (ASP) review. Preimplementation, alerts were reviewed retrospectively. Postimplementation, alerts were reviewed in real-time. Data collection included total number of actionable alerts, recommendation acceptance rates, and time spent on each alert. Time to de-escalation to narrower spectrum agents was collected. Results: In total, 749 alerts were evaluated. Overall, 306 (41%) alerts were actionable (173 preimplementation, 133 postimplementation). Rates of actionable alerts were similar for custom-built and prebuilt alert types (39% [53 of 135] vs 41% [253 of 614], P = .68]. In the postimplementation group, an intervention was attempted in 97% of actionable alerts and 70% of interventions were accepted. The median time spent per alert was 7 minutes (interquartile range [IQR], 5-13 minutes; 15 [12-17] minutes for actionable alerts vs 6 [5-7] minutes for nonactionable alerts, P < .001). In cases where the antimicrobial was eventually de-escalated, the median time to de-escalation was 28.8 hours (95% confidence interval [CI], 10.0-69.1 hours) preimplementation vs 4.7 hours (95% CI, 2.4-22.1 hours) postimplementation, P < .001. Conclusions: CDSS have played an important role in ASPs to help identify opportunities to optimize antimicrobial use through prebuilt and custom-built alerts. As ASP roles continue to expand, focusing time on customizing institution specific alerts will be of vital importance to help redistribute time needed to manage other ASP tasks and opportunities.

  8. Effects of granulation on organic acid metabolism and its relation to mineral elements in Citrus grandis juice sacs.

    PubMed

    Wang, Xian-You; Wang, Ping; Qi, Yi-Ping; Zhou, Chen-Ping; Yang, Lin-Tong; Liao, Xin-Yan; Wang, Liu-Qing; Zhu, Dong-Huang; Chen, Li-Song

    2014-02-15

    We investigated the effects of granulation on organic acid metabolism and its relation to mineral elements in 'Guanximiyou' pummelo (Citrus grandis) juice sacs. Granulated juice sacs had decreased concentrations of citrate and isocitrate, thus lowering juice sac acidity. By contrast, malate concentration was higher in granulated juice sacs than in normal ones. The reduction in citrate concentration might be caused by increased degradation, as indicated by enhanced aconitase activity, whilst the increase in malate concentration might be caused by increased biosynthesis, as indicated by enhanced phosphoenolpyruvate carboxylase (PEPC). Real time quantitative reverse transcription PCR (qRT-PCR) analysis showed that the activities of most acid-metabolizing enzymes were regulated at the transcriptional level, whilst post-translational modifications might influence the PEPC activity. Granulation led to increased accumulation of mineral elements (especially phosphorus, magnesium, sulphur, zinc and copper) in juice sacs, which might be involved in the incidence of granulation in pummelo fruits. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Ultrastructure of the endolymphatic sac in the larva of the japanese red-bellied newt Cynops pyrrhogaster

    NASA Technical Reports Server (NTRS)

    Gao, W.; Wiederhold, M.; Hejl, R.

    1998-01-01

    The ultrastructure of the endolymphatic sac (ES) of the late stage larva of the Japanese red-bellied newt, Cynops pyrrhogaster (stage 57), was examined by light and transmission electron microscopy. The two endolymphatic sacs are located at the dorsal-medial side of the otic vesicle on the dorsal-lateral side of the midbrain in the cranial cavity. The wall of the sac is composed of a layer of cubical epithelial cells with loose, interposed intercellular spaces. The sac contains a large luminal cavity, in which endolymph and numerous otoconia are present. The epithelial cells of different portions of the sac have a similar structure. These cells contain an abundance of cytoplasmic organelles, including ribosomes, Golgi complexes, and numerous vesicles. Two types of vesicles are found in the epithelial cells: the "floccular" vesicle and the "granular" vesicle. The floccular vesicles are located in the supra- and lateral-nuclear cytoplasm and contain floccular material. The granular vesicles have a fine granular substance and are usually situated apposed to the apical cell membrane. The granular vesicles are suggested to be secreted into the lumen, while the floccular vesicles are thought to be absorbed from the lumen and conveyed to the intercellular spaces by the epithelial cells. The apical surfaces of the epithelial cells bear numerous microvilli. Apparently floating cells, which bear long microvilli on the free surfaces, are observed in the lumen of the ES. Based on the fine structure, the function of the endolymphatic sac of the newt Cynops pyrrhogaster is discussed.

  10. Altered callose deposition during embryo sac formation of multi-pistil mutant (mp1) in Medicago sativa.

    PubMed

    Zhou, H C; Jin, L; Li, J; Wang, X J

    2016-06-03

    Whether callose deposition is the cause or result of ovule sterility in Medicago sativa remains controversial, because it is unclear when and where changes in callose deposition and dissolution occur during fertile and sterile embryo sac formation. Here, alfalfa spontaneous multi-pistil mutant (mp1) and wild-type plants were used to compare the dynamics of callose deposition during embryo sac formation using microscopy. The results showed that both mutant and wild-type plants experienced megasporogenesis and megagametogenesis, and there was no significant difference during megasporogenesis. In contrast to the wild-type plants, in which the mature embryo sac was observed after three continuous cycles of mitosis, functional megaspores of mutant plants developed abnormally after the second round of mitosis, leading to degeneration of synergid, central, and antipodal cells. Callose deposition in both mutant and wild-type plants was first observed in the walls of megasporocytes, and then in the megaspore tetrad walls. After meiosis, the callose wall began to degrade as the functional megaspore underwent mitosis, and almost no callose was observed in the mature embryo sac in wild-type plants. However, callose deposition was observed in mp1 plants around the synergid, and increased with the development of the embryo sac, and was mainly deposited at the micropylar end. Our results indicate that synergid, central, and antipodal cells, which are surrounded by callose, may degrade owing to lack of nutrition. Callose accumulation around the synergid and at the micropylar end may hinder signals required for the pollen tube to enter the embryo sac, leading to abortion.

  11. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City

    PubMed Central

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-01-01

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers’ and cyclists’ Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper. PMID:26230695

  12. V-Alert: Description and Validation of a Vulnerable Road User Alert System in the Framework of a Smart City.

    PubMed

    Hernandez-Jayo, Unai; De-la-Iglesia, Idoia; Perez, Jagoba

    2015-07-29

    V-Alert is a cooperative application to be deployed in the frame of Smart Cities with the aim of reducing the probability of accidents involving Vulnerable Road Users (VRU) and vehicles. The architecture of V-Alert combines short- and long-range communication technologies in order to provide more time to the drivers and VRU to take the appropriate maneuver and avoid a possible collision. The information generated by mobile sensors (vehicles and cyclists) is sent over this heterogeneous communication architecture and processed in a central server, the Drivers Cloud, which is in charge of generating the messages that are shown on the drivers' and cyclists' Human Machine Interface (HMI). First of all, V-Alert has been tested in a simulated scenario to check the communications architecture in a complex scenario and, once it was validated, all the elements of V-Alert have been moved to a real scenario to check the application reliability. All the results are shown along the length of this paper.

  13. Vienna SAC-SOS: Analysis of the European VLBI Sessions

    NASA Astrophysics Data System (ADS)

    Ros, C. T.; Pavetich, P.; Nilsson, T.; Böhm, J.; Schuh, H.

    2012-12-01

    The Institute of Geodesy and Geophysics (IGG) of the Vienna University of Technology as an IVS Special Analysis Center for Specific Observing Sessions (SAC-SOS) has analyzed the European VLBI sessions using the software VieVS. Between 1990 and 2011, 115 sessions have been carried out. The analyzed baselines have lengths ranging from approximately 445 to 4580 km, and they show good repeatabilities, apart from the ones containing station Simeiz. The station velocities have also been investigated. The stations situated in the stable part of Europe have not shown significant relative movements w.r.t. Wettzell, whereas the stations located in the northern areas have the largest vertical motions as a result of the post glacial isostatic rebound of the zone. The stations placed in Italy, around the Black Sea, in Siberia, and near the Arctic Circle show the largest relative horizontal motions because they belong to different geodynamical units.

  14. Commercial Motor Vehicle Driver Fatigue And Alertness Study Executive Summary

    DOT National Transportation Integrated Search

    1996-11-01

    THE DRIVER FATIGUE AND ALERTNESS STUDY (DFAS) WAS THE LARGEST AND MOST COMPREHENSIVE OVER-THE-ROAD STUDY EVER CONDUCTED ON DRIVER FATIGUE AND ALERTNESS IN NORTH AMERICA. IT PROVIDES EXTENSIVE INFORMATION ON THE ALERTNESS, DRIVING PERFORMANCE, AND PHY...

  15. Provider management strategies of abnormal test result alerts: a cognitive task analysis

    PubMed Central

    Sawhney, Mona K; Wilson, Lindsay; Sittig, Dean F; Espadas, Donna; Davis, Traber; Singh, Hardeep

    2010-01-01

    Objective Electronic medical records (EMRs) facilitate abnormal test result communication through “alert” notifications. The aim was to evaluate how primary care providers (PCPs) manage alerts related to critical diagnostic test results on their EMR screens, and compare alert-management strategies of providers with high versus low rates of timely follow-up of results. Design 28 PCPs from a large, tertiary care Veterans Affairs Medical Center (VAMC) were purposively sampled according to their rates of timely follow-up of alerts, determined in a previous study. Using techniques from cognitive task analysis, participants were interviewed about how and when they manage alerts, focusing on four alert-management features to filter, sort and reduce unnecessary alerts on their EMR screens. Results Provider knowledge of alert-management features ranged between 4% and 75%. Almost half (46%) of providers did not use any of these features, and none used more than two. Providers with higher versus lower rates of timely follow-up used the four features similarly, except one (customizing alert notifications). Providers with low rates of timely follow-up tended to manually scan the alert list and process alerts heuristically using their clinical judgment. Additionally, 46% of providers used at least one workaround strategy to manage alerts. Conclusion Considerable heterogeneity exists in provider use of alert-management strategies; specific strategies may be associated with lower rates of timely follow-up. Standardization of alert-management strategies including improving provider knowledge of appropriate tools in the EMR to manage alerts could reduce the lack of timely follow-up of abnormal diagnostic test results. PMID:20064805

  16. Evaluation of Refractivity Profiles from CHAMP and SAC-C GPS Radio Occultation

    NASA Technical Reports Server (NTRS)

    Poli, Paul; Ao, Chi On; Joiner, Joanna; delaTorreJuarez, Manuel; Hoff, Raymond

    2002-01-01

    The GeoForschungsZentrum's Challenging Minisatellite Payload for Geophysical Research and Application (CHAMP, Germany-US) and the Comision Nacional de Actividades Especiales' Satelite de Aplicaciones Cientificas-C (SAC-C, Argentina-US) missions are the first missions to carry a second-generation Blackjack Global Positioning System (GPS) receiver. One of the new features of this receiver is its ability to sense the lower troposphere closer to the surface than the proof-of-concept GPS Meteorology experiment (GPS/MET). Since their launch, CHAMP and SAC-C have collected thousands of GPS radio occultations, representing a wealth of measurements available for data assimilation and Numerical Weather Prediction (NWP). In order to evaluate the refractivity data derived by the Jet Propulsion Laboratory (JPL) from raw radio occultation measurements, we use Data Assimilation Office (DAO) 6-hour forecasts as an independent state of the atmosphere. We compare CHAMP and SAC-C refractivity (processed by JPL) with refractivity calculated from the DAO global fields of temperature, water vapor content and humidity. We show statistics of the differences as well as histograms of the differences.

  17. Project "Hypertension Alert."

    ERIC Educational Resources Information Center

    Sailors, Emma Lou

    1983-01-01

    "Hypertension Alert," a 1979-80 blood pressure screening-awareness project of the Yonkers, New York Public Schools, is described. Data is analyzed in tables for ethnic composition, and range of blood pressure readings for the high school, junior high school, and elementary school students tested. (Author/JMK)

  18. 47 CFR 80.334 - False distress alerts.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...

  19. 47 CFR 80.334 - False distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...

  20. 47 CFR 80.334 - False distress alerts.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...

  1. 47 CFR 80.334 - False distress alerts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...

  2. 47 CFR 80.334 - False distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....S. Coast Guard; (d) Was repeated; or (e) Was transmitted using a false identity. [68 FR 46968, Aug... § 80.334 False distress alerts. A distress alert is false if it was transmitted without any indication that a mobile unit or person was in distress and required immediate assistance. Transmitting a false...

  3. An unusual foreign body in the preputial sac.

    PubMed Central

    Jaiswal, A K

    1992-01-01

    A 28 year old Indian male presented with an unusual foreign body, a penicillin bottle containing tincture of iodine, in the preputial sac. The purpose of introducing the bottle was to tickle his glans penis as a form of masturbation. The bottle was so firmly impacted that it could be removed only under general anaesthesia. Images PMID:1427809

  4. Differential effects of phasic and tonic alerting on the efficiency of executive attention.

    PubMed

    Asanowicz, Dariusz; Marzecová, Anna

    2017-05-01

    The study examined how alerting and executive attention interact in a task involving conflict resolution. We proposed a tentative scenario in which an initial exogenous phasic alerting phase is followed by an endogenous tonic alerting phase, and hypothesized that these two processes may have distinct effects on conflict resolution. Phasic alerting was expected to increase the conflict, whereas tonic alerting was expected to decrease the conflict. Three experiments were conducted using different variants of the flanker task with visual alerting cues and varied cue-target intervals (SOA), to differentiate between effects of phasic alerting (short SOA) and tonic alerting (long SOA). The results showed that phasic alerting consistently decreased the efficiency of conflict resolution indexed by response time and accuracy, whereas tonic alerting increased the accuracy of conflict resolution, but at a cost in the speed of processing the conflict. The third experiment additionally showed that the effects of phasic alerting may be modulated by the psychophysical strength of alerting cues. Discussed are possible mechanisms that could account for the observed interactions between alerting and conflict resolution, as well as some discrepancies between the current and previous studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. β-Globin-Expressing Definitive Erythroid Progenitor Cells Generated from Embryonic and Induced Pluripotent Stem Cell-Derived Sacs.

    PubMed

    Fujita, Atsushi; Uchida, Naoya; Haro-Mora, Juan J; Winkler, Thomas; Tisdale, John

    2016-06-01

    Human embryonic stem (ES) cells and induced pluripotent stem (iPS) cells represent a potential alternative source for red blood cell transfusion. However, when using traditional methods with embryoid bodies, ES cell-derived erythroid cells predominantly express embryonic type ɛ-globin, with lesser fetal type γ-globin and very little adult type β-globin. Furthermore, no β-globin expression is detected in iPS cell-derived erythroid cells. ES cell-derived sacs (ES sacs) have been recently used to generate functional platelets. Due to its unique structure, we hypothesized that ES sacs serve as hemangioblast-like progenitors capable to generate definitive erythroid cells that express β-globin. With our ES sac-derived erythroid differentiation protocol, we obtained ∼120 erythroid cells per single ES cell. Both primitive (ɛ-globin expressing) and definitive (γ- and β-globin expressing) erythroid cells were generated from not only ES cells but also iPS cells. Primitive erythropoiesis is gradually switched to definitive erythropoiesis during prolonged ES sac maturation, concurrent with the emergence of hematopoietic progenitor cells. Primitive and definitive erythroid progenitor cells were selected on the basis of glycophorin A or CD34 expression from cells within the ES sacs before erythroid differentiation. This selection and differentiation strategy represents an important step toward the development of in vitro erythroid cell production systems from pluripotent stem cells. Further optimization to improve expansion should be required for clinical application. Stem Cells 2016;34:1541-1552. © 2016 AlphaMed Press.

  6. Correlation of two bioadhesion assays: the everted sac technique and the CAHN microbalance.

    PubMed

    Santos, C A; Jacob, J S; Hertzog, B A; Freedman, B D; Press, D L; Harnpicharnchai, P; Mathiowitz, E

    1999-08-27

    This contribution correlates two in vitro methods utilized to determine bioadhesion. One method, the everted intestinal sac technique, is a passive test for bioadhesion involving several polymer microspheres and a section of everted intestinal tissue. The other method, the CAHN microbalance, employs a CAHN dynamic contact angle analyzer with modified software to record the tensile forces measured as a single polymer microsphere is pulled from intestinal tissue. This study demonstrates that CAHN and everted sac experiments yield similar results when used to quantify the bioadhesive nature of polymer microsphere systems. A polymer showing high adhesion in one method also demonstrates high bioadhesion in the other method; polymers that exhibit high fracture strength and tensile work measurements with the CAHN microbalance also yield high binding percentages with the everted sac method. The polymers tested and reported here are poly(caprolactone) and different copolymer ratios of poly(fumaric-co-sebacic anhydride). The results of this correlation demonstrate that each method alone is a valuable indicator of bioadhesion.

  7. Whisker Formation on SAC305 Soldered Assemblies

    NASA Astrophysics Data System (ADS)

    Meschter, S.; Snugovsky, P.; Bagheri, Z.; Kosiba, E.; Romansky, M.; Kennedy, J.; Snugovsky, L.; Perovic, D.

    2014-11-01

    This article describes the results of a whisker formation study on SAC305 assemblies, evaluating the effects of lead-frame materials and cleanliness in different environments: low-stress simulated power cycling (50-85°C thermal cycling), thermal shock (-55°C to 85°C), and high temperature/high humidity (85°C/85% RH). Cleaned and contaminated small outline transistors, large leaded quad flat packs (QFP), plastic leaded chip carrier packages, and solder balls with and without rare earth elements (REE) were soldered to custom designed test boards with Sn3Ag0.5Cu (SAC305) solder. After assembly, all the boards were cleaned, and half of them were recontaminated (1.56 µg/cm2 Cl-). Whisker length, diameter, and density were measured. Detailed metallurgical analysis on components before assembly and on solder joints before and after testing was performed. It was found that whiskers grow from solder joint fillets, where the thickness is less than 25 µm, unless REE was present. The influence of lead-frame and solder ball material, microstructure, cleanliness, and environment on whisker characteristics is discussed. This article provides detailed metallurgical observations and select whisker length data obtained during this multiyear testing program.

  8. Evaluation of health alerts from an early illness warning system in independent living.

    PubMed

    Rantz, Marilyn J; Scott, Susan D; Miller, Steven J; Skubic, Marjorie; Phillips, Lorraine; Alexander, Greg; Koopman, Richelle J; Musterman, Katy; Back, Jessica

    2013-06-01

    Passive sensor networks were deployed in independent living apartments to monitor older adults in their home environments to detect signs of impending illness and alert clinicians so they can intervene and prevent or delay significant changes in health or functional status. A retrospective qualitative deductive content analysis was undertaken to refine health alerts to improve clinical relevance to clinicians as they use alerts in their normal workflow of routine care delivery to older adults. Clinicians completed written free-text boxes to describe actions taken (or not) as a result of each alert; they also rated the clinical significance (relevance) of each health alert on a scale of 1 to 5. Two samples of the clinician's written responses to the health alerts were analyzed after alert algorithms had been adjusted based on results of a pilot study using health alerts to enhance clinical decision-making. In the first sample, a total of 663 comments were generated by seven clinicians in response to 385 unique alerts; there are more comments than alerts because more than one clinician rated the same alert. The second sample had a total of 142 comments produced by three clinicians in response to 88 distinct alerts. The overall clinical relevance of the alerts, as judged by the content of the qualitative comments by clinicians for each alert, improved from 33.3% of the alerts in the first sample classified as clinically relevant to 43.2% in the second. The goal is to produce clinically relevant alerts that clinicians find useful in daily practice. The evaluation methods used are described to assist others as they consider building and iteratively refining health alerts to enhance clinical decision making.

  9. A framework for evaluating the appropriateness of clinical decision support alerts and responses

    PubMed Central

    Waitman, Lemuel R; Lewis, Julia B; Wright, Julie A; Choma, David P; Miller, Randolph A; Peterson, Josh F

    2011-01-01

    Objective Alerting systems, a type of clinical decision support, are increasingly prevalent in healthcare, yet few studies have concurrently measured the appropriateness of alerts with provider responses to alerts. Recent reports of suboptimal alert system design and implementation highlight the need for better evaluation to inform future designs. The authors present a comprehensive framework for evaluating the clinical appropriateness of synchronous, interruptive medication safety alerts. Methods Through literature review and iterative testing, metrics were developed that describe successes, justifiable overrides, provider non-adherence, and unintended adverse consequences of clinical decision support alerts. The framework was validated by applying it to a medication alerting system for patients with acute kidney injury (AKI). Results Through expert review, the framework assesses each alert episode for appropriateness of the alert display and the necessity and urgency of a clinical response. Primary outcomes of the framework include the false positive alert rate, alert override rate, provider non-adherence rate, and rate of provider response appropriateness. Application of the framework to evaluate an existing AKI medication alerting system provided a more complete understanding of the process outcomes measured in the AKI medication alerting system. The authors confirmed that previous alerts and provider responses were most often appropriate. Conclusion The new evaluation model offers a potentially effective method for assessing the clinical appropriateness of synchronous interruptive medication alerts prior to evaluating patient outcomes in a comparative trial. More work can determine the generalizability of the framework for use in other settings and other alert types. PMID:21849334

  10. Regulation of ascorbic acid metabolism by blue LED light irradiation in citrus juice sacs.

    PubMed

    Zhang, Lancui; Ma, Gang; Yamawaki, Kazuki; Ikoma, Yoshinori; Matsumoto, Hikaru; Yoshioka, Terutaka; Ohta, Satoshi; Kato, Masaya

    2015-04-01

    In the present study, the effects of red and blue LED lights on the accumulation of ascorbic acid (AsA) were investigated in the juice sacs of three citrus varieties, Satsuma mandarin, Valencia orange, and Lisbon lemon. The results showed that the blue LED light treatment effectively increased the AsA content in the juice sacs of the three citrus varieties, whereas the red LED light treatment did not. By increasing the blue LED light intensity, the juice sacs of the three citrus varieties accumulated more AsA. Moreover, continuous irradiation with blue LED light was more effective than pulsed irradiation for increasing the AsA content in the juice sacs of the three citrus varieties. Gene expression results showed that the modulation of AsA accumulation by blue LED light was highly regulated at the transcription level. The up-regulation of AsA biosynthetic genes (CitVTC1, CitVTC2, CitVTC4, and CitGLDH), AsA regeneration genes (CitMDAR1, CitMDAR2, and CitDHAR) and two GSH-producing genes (CitGR and CitchGR) contributed to these increases in the AsA content in the three citrus varieties. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Electronic Immunization Alerts and Spillover Effects on Other Preventive Care.

    PubMed

    Kim, Julia M; Rivera, Maria; Persing, Nichole; Bundy, David G; Psoter, Kevin J; Ghazarian, Sharon R; Miller, Marlene R; Solomon, Barry S

    2017-08-01

    The impact of electronic health record (EHR) immunization clinical alert systems on the delivery of other preventive services remains unknown. We assessed for spillover effects of an EHR immunization alert on delivery of 6 other preventive services, in children 18 to 30 months of age needing immunizations. We conducted a secondary data analysis, with additional primary data collection, of a randomized, historically controlled trial to improve immunization rates with EHR alerts, in an urban, primary care clinic. No significant differences were found in screening for anemia, lead, development, nutrition, and injury prevention counseling in children prompting EHR immunization alerts (n = 129), compared with controls (n = 135). Significant increases in oral health screening in patients prompting EHR alerts (odds ratio = 4.8, 95% CI = 1.8-13.0) were likely due to practice changes over time. An EHR clinical alert system targeting immunizations did not have a spillover effect on the delivery of other preventive services.

  12. Air sac nematode Monopetalonema alcedinis in a Belted Kingfisher (Megaceryle alcyon) in Maryland, USA.

    PubMed

    Bronson, Ellen; Kelly, Kathleen; Hoberg, Eric P

    2014-10-01

    Sporadic and geographically widespread reports of parasites affecting the Belted Kingfisher (Megaceryle alcyon) have been published but few have described details of the pathology. A female, adult kingfisher was found dead in a heavily wooded area of a zoo in Maryland, USA. At necropsy, numerous sexually dimorphic, 4.4-40.5-cm adult Monopetalonema alcedinis nematodes were found tightly wound within the coelomic cavity between organs and completely filling the caudal thoracic and abdominal air sacs. Abundant, 30-60-µm diameter, larvated, thick-walled ova were found in the bronchi and parabronchi, within the mesentery, and in the serosa of multiple coelomic organs. Monopetalonema alcedinis is a characteristic member of the superfamily Diplotriaenoidea, a group of nematodes occurring in birds and reptiles. Infective larvae within an invertebrate intermediate host are ingested and penetrate the intestine, traveling to the lungs and then into the air sacs, where the adult females release eggs. The ova are coughed up by the avian host and passed in feces. Specimens of M. alcedinis have been found in the Belted Kingfisher, although typically intensity of infection is low and infections remain asymptomatic. In contrast, we report the second documented case of high numbers of M. alcedinis resulting in pathologic changes in which parasitism contributed to host mortality.

  13. PleurAlert: an augmented chest drainage system with electronic sensing, automated alerts and internet connectivity.

    PubMed

    Leeson, Cory E; Weaver, Robert A; Bissell, Taylor; Hoyer, Rachel; McClain, Corinne; Nelson, Douglas A; Samosky, Joseph T

    2012-01-01

    We have enhanced a common medical device, the chest tube drainage container, with electronic sensing of fluid volume, automated detection of critical alarm conditions and the ability to automatically send alert text messages to a nurse's cell phone. The PleurAlert system provides a simple touch-screen interface and can graphically display chest tube output over time. Our design augments a device whose basic function dates back 50 years by adding technology to automate and optimize a monitoring process that can be time consuming and inconvenient for nurses. The system may also enhance detection of emergency conditions and speed response time.

  14. A new method for determining a sector alert

    DOT National Transportation Integrated Search

    2008-09-29

    The Traffic Flow Management System (TFMS) currently declares an alert for any 15-minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP) for any airport, sector, or fix. For a sector, TFMS predicts the demand for each ...

  15. 47 CFR 11.56 - EAS Participants receive CAP-formatted alerts.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false EAS Participants receive CAP-formatted alerts... SYSTEM (EAS) Emergency Operations § 11.56 EAS Participants receive CAP-formatted alerts. Notwithstanding anything herein to the contrary, all EAS Participants must be able to receive CAP-formatted EAS alerts no...

  16. Maximizing Trust in the Wireless Emergency Alerts (WEA) Service

    DTIC Science & Technology

    2014-02-01

    Homeland Security under Contract No. FA8721-05-C-0003 with Carnegie Mellon University for the operation of the Software En - gineering Institute, a...AOs will protect their alert-generating systems from misuse. A compro- mised alert-generating system could overload the IPAWS-OPEN message validation...greater accessibility, such as accessing the WEA service re- motely from the scene of an incident. Although we are currently unaware of any alerting

  17. Acute alerting effects of light: A systematic literature review.

    PubMed

    Souman, Jan L; Tinga, Angelica M; Te Pas, Susan F; van Ee, Raymond; Vlaskamp, Björn N S

    2018-01-30

    Periodic, well timed exposure to light is important for our health and wellbeing. Light, in particular in the blue part of the spectrum, is thought to affect alertness both indirectly, by modifying circadian rhythms, and directly, giving rise to acute effects. We performed a systematic review of empirical studies on direct, acute effects of light on alertness to evaluate the reliability of these effects. In total, we identified 68 studies in which either light intensity, spectral distribution, or both were manipulated, and evaluated the effects on behavioral measures of alertness, either subjectively or measured in reaction time performance tasks. The results show that increasing the intensity of polychromatic white light has been found to increase subjective ratings of alertness in a majority of studies, though a substantial proportion of studies failed to find significant effects, possibly due to small sample sizes or high baseline light intensities. The effect of the color temperature of white light on subjective alertness is less clear. Some studies found increased alertness with higher color temperatures, but other studies reported no detrimental effects of filtering out the short wavelengths from the spectrum. Similarly, studies that used monochromatic light exposure showed no systematic pattern for the effects of blue light compared to longer wavelengths. Far fewer studies investigated the effects of light intensity or spectrum on alertness as measured with reaction time tasks and of those, very few reported significant effects. In general, the small sample sizes used in studies on acute alerting effects of light make it difficult to draw definitive conclusions and better powered studies are needed, especially studies that allow for the construction of dose-response curves. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Unusual presentation of Enterobius vermicularis in conjunctival sac.

    PubMed

    Mallick, Sanjay Kumar; Sengupta, Ranadeep; Banerjee, Arup Kumar

    2015-10-01

    We report an unusual case of extraintestinal infection with adult Enterobius vermicularis worms in the conjunctival sac of a two-and-a-half year old boy from Alipurduar, West Bengal, India. Only two other similar cases have been reported in the English literature, one from Assam, India in 1976, and the other from Illinois and California in 2011. © The Author(s) 2014.

  19. The national web-based outbreak rapid alert system in Norway: eight years of experience, 2006-2013.

    PubMed

    Guzman-Herrador, B; Vold, L; Berg, T; Berglund, T M; Heier, B; Kapperud, G; Lange, H; Nygård, K

    2016-01-01

    In 2005, the Norwegian Institute of Public Health established a web-based outbreak rapid alert system called Vesuv. The system is used for mandatory outbreak alerts from municipal medical officers, healthcare institutions, and food safety authorities. As of 2013, 1426 outbreaks have been reported, involving 32913 cases. More than half of the outbreaks occurred in healthcare institutions (759 outbreaks, 53·2%). A total of 474 (33·2%) outbreaks were associated with food or drinking water. The web-based rapid alert system has proved to be a helpful tool by enhancing reporting and enabling rapid and efficient information sharing between different authorities at both the local and national levels. It is also an important tool for event-based reporting, as required by the International Health Regulations (IHR) 2005. Collecting information from all the outbreak alerts and reports in a national database is also useful for analysing trends, such as occurrence of certain microorganisms, places or sources of infection, or route of transmission. This can facilitate the identification of specific areas where more general preventive measures are needed.

  20. Evaluating Alerting and Guidance Performance of a UAS Detect-And-Avoid System

    NASA Technical Reports Server (NTRS)

    Lee, Seung Man; Park, Chunki; Thipphavong, David P.; Isaacson, Douglas R.; Santiago, Confesor

    2016-01-01

    A key challenge to the routine, safe operation of unmanned aircraft systems (UAS) is the development of detect-and-avoid (DAA) systems to aid the UAS pilot in remaining "well clear" of nearby aircraft. The goal of this study is to investigate the effect of alerting criteria and pilot response delay on the safety and performance of UAS DAA systems in the context of routine civil UAS operations in the National Airspace System (NAS). A NAS-wide fast-time simulation study was conducted to assess UAS DAA system performance with a large number of encounters and a broad set of DAA alerting and guidance system parameters. Three attributes of the DAA system were controlled as independent variables in the study to conduct trade-off analyses: UAS trajectory prediction method (dead-reckoning vs. intent-based), alerting time threshold (related to predicted time to LoWC), and alerting distance threshold (related to predicted Horizontal Miss Distance, or HMD). A set of metrics, such as the percentage of true positive, false positive, and missed alerts, based on signal detection theory and analysis methods utilizing the Receiver Operating Characteristic (ROC) curves were proposed to evaluate the safety and performance of DAA alerting and guidance systems and aid development of DAA system performance standards. The effect of pilot response delay on the performance of DAA systems was evaluated using a DAA alerting and guidance model and a pilot model developed to support this study. A total of 18 fast-time simulations were conducted with nine different DAA alerting threshold settings and two different trajectory prediction methods, using recorded radar traffic from current Visual Flight Rules (VFR) operations, and supplemented with DAA-equipped UAS traffic based on mission profiles modeling future UAS operations. Results indicate DAA alerting distance threshold has a greater effect on DAA system performance than DAA alerting time threshold or ownship trajectory prediction method

  1. Diagnostic accuracy of a screening electronic alert tool for severe sepsis and septic shock in the emergency department.

    PubMed

    Alsolamy, Sami; Al Salamah, Majid; Al Thagafi, Majed; Al-Dorzi, Hasan M; Marini, Abdellatif M; Aljerian, Nawfal; Al-Enezi, Farhan; Al-Hunaidi, Fatimah; Mahmoud, Ahmed M; Alamry, Ahmed; Arabi, Yaseen M

    2014-12-05

    Early recognition of severe sepsis and septic shock is challenging. The aim of this study was to determine the diagnostic accuracy of an electronic alert system in detecting severe sepsis or septic shock among emergency department (ED) patients. An electronic sepsis alert system was developed as a part of a quality-improvement project for severe sepsis and septic shock. The system screened all adult ED patients for a combination of systemic inflammatory response syndrome and organ dysfunction criteria (hypotension, hypoxemia or lactic acidosis). This study included all patients older than 14 years who presented to the ED of a tertiary care academic medical center from Oct. 1, 2012 to Jan. 31, 2013. As a comparator, emergency medicine physicians or the critical care physician identified the patients with severe sepsis or septic shock. In the ED, vital signs were manually entered into the hospital electronic heath record every hour in the critical care area and every two hours in other areas. We also calculated the time from the alert to the intensive care unit (ICU) referral. Of the 49,838 patients who presented to the ED, 222 (0.4%) were identified to have severe sepsis or septic shock. The electronic sepsis alert had a sensitivity of 93.18% (95% CI, 88.78% - 96.00%), specificity of 98.44 (95% CI, 98.33% - 98.55%), positive predictive value of 20.98% (95% CI, 18.50% - 23.70%) and negative predictive value of 99.97% (95% CI, 99.95% - 99.98%) for severe sepsis and septic shock. The alert preceded ICU referral by a median of 4.02 hours (Q1 - Q3: 1.25-8.55). Our study shows that electronic sepsis alert tool has high sensitivity and specificity in recognizing severe sepsis and septic shock, which may improve early recognition and management.

  2. Adoption of medication alert systems in hospital outpatient departments in Taiwan.

    PubMed

    Kuo, Yu-Chun; Cheng, Shou-Hsia

    2017-06-01

    The adoption of medication alert systems in the health care sector varies among regions. In Taiwan, the health authority introduced policies in 2005 to encourage the adoption of medication alert systems in hospitals. This study aimed to understand the adoption of medication alert systems in the outpatient departments of hospitals in Taiwan using a nationwide survey. A questionnaire was developed and mailed to 380 accredited general hospitals in Taiwan in 2013. The information collected from the questionnaire concerning the outpatient department included (1) the time of adoption of a medication alert system; (2) the operation of individual alert functions: availability, management, and stability; and (3) hospital characteristics: accreditation level, teaching status, ownership, and number of beds. A total of 216 hospitals completed and returned the questionnaire, corresponding to a response rate of 56.8%. The adoption rate of medication alert systems in hospital outpatient departments increased from less than 10% in 1997-95.83% in 2012. Approximately two-thirds of the hospitals developed and maintained the alert systems independently or collaboratively with vendors. Teaching and large hospitals tended to develop more advanced alert functions such as drug-drug interaction functions. Improving the safety and quality of pharmaceutical services and meeting the policy requirements are reasons for hospitals to establish medication alert systems. The adoption rate of medication alert systems reached 95% in accredited general hospitals in Taiwan. Government policy and available health information professionals and vendors may somewhat contribute to the high adoption rate. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Alertness Modulates Conflict Adaptation and Feature Integration in an Opposite Way

    PubMed Central

    Chen, Jia; Huang, Xiting; Chen, Antao

    2013-01-01

    Previous studies show that the congruency sequence effect can result from both the conflict adaptation effect (CAE) and feature integration effect which can be observed as the repetition priming effect (RPE) and feature overlap effect (FOE) depending on different experimental conditions. Evidence from neuroimaging studies suggests that a close correlation exists between the neural mechanisms of alertness-related modulations and the congruency sequence effect. However, little is known about whether and how alertness mediates the congruency sequence effect. In Experiment 1, the Attentional Networks Test (ANT) and a modified flanker task were used to evaluate whether the alertness of the attentional functions had a correlation with the CAE and RPE. In Experimental 2, the ANT and another modified flanker task were used to investigate whether alertness of the attentional functions correlate with the CAE and FOE. In Experiment 1, through the correlative analysis, we found a significant positive correlation between alertness and the CAE, and a negative correlation between the alertness and the RPE. Moreover, a significant negative correlation existed between CAE and RPE. In Experiment 2, we found a marginally significant negative correlation between the CAE and the RPE, but the correlation between alertness and FOE, CAE and FOE was not significant. These results suggest that alertness can modulate conflict adaptation and feature integration in an opposite way. Participants at the high alerting level group may tend to use the top-down cognitive processing strategy, whereas participants at the low alerting level group tend to use the bottom-up processing strategy. PMID:24250824

  4. How Regrouping Alerts in Computerized Physician Order Entry Layout Influences Physicians' Prescription Behavior: Results of a Crossover Randomized Trial.

    PubMed

    Wipfli, Rolf; Ehrler, Frederic; Bediang, Georges; Bétrancourt, Mireille; Lovis, Christian

    2016-06-02

    As demonstrated in several publications, low positive predictive value alerts in computerized physician order entry (CPOE) induce fatigue and may interrupt physicians unnecessarily during prescription of medication. Although it is difficult to increase the consideration of medical alerts by physician through an improvement of their predictive value, another approach consists to act on the way they are presented. The interruption management model inspired us to propose an alternative alert display strategy of regrouping the alerts in the screen layout, as a possible solution for reducing the interruption in physicians' workflow. In this study, we compared 2 CPOE designs based on a particular alert presentation strategy: one design involved regrouping the alerts in a single place on the screen, and in the other, the alerts were located next to the triggering information. Our objective was to evaluate experimentally whether the new design led to fewer interruptions in workflow and if it affected alert handling. The 2 CPOE designs were compared in a controlled crossover randomized trial. All interactions with the system and eye movements were stored for quantitative analysis. The study involved a group of 22 users consisting of physicians and medical students who solved medical scenarios containing prescription tasks. Scenario completion time was shorter when the alerts were regrouped (mean 117.29 seconds, SD 36.68) than when disseminated on the screen (mean 145.58 seconds, SD 75.07; P=.045). Eye tracking revealed that physicians fixated longer on alerts in the classic design (mean 119.71 seconds, SD 76.77) than in the centralized alert design (mean 70.58 seconds, SD 33.53; P=.001). Visual switches between prescription and alert areas, indicating interruption, were reduced with centralized alerts (mean 41.29, SD 21.26) compared with the classic design (mean 57.81, SD 35.97; P=.04). Prescription behavior (ie, prescription changes after alerting), however, did not change

  5. 47 CFR 10.320 - Provider alert gateway requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Provider alert gateway requirements. 10.320 Section 10.320 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL COMMERCIAL MOBILE ALERT SYSTEM... that each Participating Commercial Mobile Service provider is required to support and perform at its...

  6. Real-time monitoring of the human alertness level

    NASA Astrophysics Data System (ADS)

    Alvarez, Robin; del Pozo, Francisco; Hernando, Elena; Gomez, Eduardo; Jimenez, Antonio

    2003-04-01

    Many accidents are associated with a driver or machine operator's alertness level. Drowsiness often develops as a result of repetitive or monotonous tasks, uninterrupted by external stimuli. In order to enhance safety levels, it would be most desirable to monitor the individual's level of attention. In this work, changes in the power spectrum of the electroencephalographic signal (EEG) are associated with the subject's level of attention. This study reports on the initial research carried out in order to answer the following important questions: (i) Does a trend exist in the shape of the power spectrum, which will indicate the state of a subject's alertness state (drowsy, relaxed or alert)? (ii) What points on the cortex are most suitable to detect drowsiness and/or high alertness? (iii) What parameters in the power spectrum are most suitable to establish a workable alertness classification in human subjects? In this work, we answer these questions and combine power spectrum estimation and artificial neural network techniques to create a non-invasive and real - time system able to classify EEG into three levels of attention: High, Relaxed and Drowsiness. The classification is made every 10 seconds o more, a suitable time span for giving an alarm signal if the individual is with insufficient level of alertness. This time span is set by the user. The system was tested on twenty subjects. High and relaxed attention levels were measured in randomise hours of the day and drowsiness attention level was measured in the morning after one night of sleep deprivation.

  7. Pilot Non-Conformance to Alerting System Commands During Closely Spaced Parallel Approaches

    NASA Technical Reports Server (NTRS)

    Pritchett, Amy Ruth; Hansman, R. John; Corker, Kevin (Technical Monitor)

    1997-01-01

    Cockpit alerting systems monitor potentially hazardous situations, both inside and outside the aircraft. When a hazard is projected to occur, the alerting system displays alerts and/or command decisions to the pilot. However, pilots have been observed to not conform to alerting system commands by delaying their response or by not following the automatic commands exactly. This non-conformance to the automatic alerting system can reduce its benefit. Therefore, a need exists to understand the causes and effects of pilot non-conformance in order to develop automatic alerting systems whose commands the pilots are more likely to follow. These considerations were examined through flight simulator evaluations of the collision avoidance task during closely spaced parallel approaches. This task provided a useful case-study because the effects of non-conformance can be significant, given the time-critical nature of the task. A preliminary evaluation of alerting systems identified non-conformance in over 40% of the cases and a corresponding drop in collision avoidance performance. A follow-on experiment found subjects' alerting and maneuver selection criteria were consistent with different strategies than those used by automatic systems, indicating the pilot may potentially disagree with the alerting system if the pilot attempts to verify automatic alerts and commanded avoidance maneuvers. A final experiment found supporting automatic alerts with the explicit display of its underlying criteria resulted in more consistent subject reactions. In light of these experimental results, a general discussion of pilot non-conformance is provided. Contributing factors in pilot non-conformance include a lack of confidence in the automatic system and mismatches between the alerting system's commands and the pilots' own decisions based on the information available to them. The effects of non-conformance on system performance are discussed. Possible methods of reconciling mismatches are

  8. Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors

    PubMed Central

    Shah, Priya; Wyatt, Jeremy C; Makubate, Boikanyo; Cross, Frank W

    2011-01-01

    Objective Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. Design A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. Measurements The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. Results Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). Conclusions Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes. PMID:21836158

  9. Using Supervised Machine Learning to Classify Real Alerts and Artifact in Online Multi-signal Vital Sign Monitoring Data

    PubMed Central

    Chen, Lujie; Dubrawski, Artur; Wang, Donghan; Fiterau, Madalina; Guillame-Bert, Mathieu; Bose, Eliezer; Kaynar, Ata M.; Wallace, David J.; Guttendorf, Jane; Clermont, Gilles; Pinsky, Michael R.; Hravnak, Marilyn

    2015-01-01

    OBJECTIVE Use machine-learning (ML) algorithms to classify alerts as real or artifacts in online noninvasive vital sign (VS) data streams to reduce alarm fatigue and missed true instability. METHODS Using a 24-bed trauma step-down unit’s non-invasive VS monitoring data (heart rate [HR], respiratory rate [RR], peripheral oximetry [SpO2]) recorded at 1/20Hz, and noninvasive oscillometric blood pressure [BP] less frequently, we partitioned data into training/validation (294 admissions; 22,980 monitoring hours) and test sets (2,057 admissions; 156,177 monitoring hours). Alerts were VS deviations beyond stability thresholds. A four-member expert committee annotated a subset of alerts (576 in training/validation set, 397 in test set) as real or artifact selected by active learning, upon which we trained ML algorithms. The best model was evaluated on alerts in the test set to enact online alert classification as signals evolve over time. MAIN RESULTS The Random Forest model discriminated between real and artifact as the alerts evolved online in the test set with area under the curve (AUC) performance of 0.79 (95% CI 0.67-0.93) for SpO2 at the instant the VS first crossed threshold and increased to 0.87 (95% CI 0.71-0.95) at 3 minutes into the alerting period. BP AUC started at 0.77 (95%CI 0.64-0.95) and increased to 0.87 (95% CI 0.71-0.98), while RR AUC started at 0.85 (95%CI 0.77-0.95) and increased to 0.97 (95% CI 0.94–1.00). HR alerts were too few for model development. CONCLUSIONS ML models can discern clinically relevant SpO2, BP and RR alerts from artifacts in an online monitoring dataset (AUC>0.87). PMID:26992068

  10. Crystal plasticity finite element analysis of deformation behaviour in SAC305 solder joint

    NASA Astrophysics Data System (ADS)

    Darbandi, Payam

    Due to the awareness of the potential health hazards associated with the toxicity of lead (Pb), actions have been taken to eliminate or reduce the use of Pb in consumer products. Among those, tin (Sn) solders have been used for the assembly of electronic systems. Anisotropy is of significant importance in all structural metals, but this characteristic is unusually strong in Sn, making Sn based solder joints one of the best examples of the influence of anisotropy. The effect of anisotropy arising from the crystal structure of tin and large grain microstructure on the microstructure and the evolution of constitutive responses of microscale SAC305 solder joints is investigated. Insights into the effects of key microstructural features and dominant plastic deformation mechanisms influencing the measured relative activity of slip systems in SAC305 are obtained from a combination of optical microscopy, orientation imaging microscopy (OIM), slip plane trace analysis and crystal plasticity finite element (CPFE) modeling. Package level SAC305 specimens were subjected to shear deformation in sequential steps and characterized using optical microscopy and OIM to identify the activity of slip systems. X-ray micro Laue diffraction and high energy monochromatic X-ray beam were employed to characterize the joint scale tensile samples to provide necessary information to be able to compare and validate the CPFE model. A CPFE model was developed that can account for relative ease of activating slip systems in SAC305 solder based upon the statistical estimation based on correlation between the critical resolved shear stress and the probability of activating various slip systems. The results from simulations show that the CPFE model developed using the statistical analysis of activity of slip system not only can satisfy the requirements associated with kinematic of plastic deformation in crystal coordinate systems (activity of slip systems) and global coordinate system (shape changes

  11. Application of a functional marker for the effect of cryoprotectant agents on gorgonian coral (Junceella juncea and J. fragilis) sperm sacs.

    PubMed

    Tsai, S; Kuit, V; Lin, Z G; Lin, C

    2014-01-01

    The establishment of coral sperm repositories which retain good post-rewarming viability and fertility play a vital role in species conservation. This study aimed at obtaining baseline information regarding the effects of cryoprotectant agents (CPAs) on gorgonian coral (Junceella juncea and J. fragilis) sperm sacs. The adenosine triphosphate assay was used to determine the energy level of the gorgonian sperm sacs as an indicator of sperm viability after exposure to cryoprotectants. The 'no observed effect concentrations' (NOECs) of methanol, dimethyl sulfoxide (DMSO), polypropylene glycol (PG), ethylene glycol (EG) and glycerol for J. juncea sperm sacs were 3 M, 3 M, 1 M, 2 M and 1 M respectively after 20 min exposure; whilst the NOECs for J. fragilis oocytes were 2 M, 3 M, 1 M, 2 M and 2 M, respectively. Methanol and DMSO had the least impact. PG was the most toxic CPA after 10 min exposure. ATP content of J. juncea and J. fragilis sperm sacs did not differ significantly from the control with incubation times of 10-20 min with 2 M EG. However, ATP content dropped significantly after exposing sperm sacs to 2 M EG for 40 min with average values of 2.34 +/- 0.12 and 1.97 +/- 0.48 microg/ml respectively. ATP content for J. juncea and J. fragilis sperm sacs was significantly decreased to 1.79 +/- 0.31 and 2.40 +/- 0.36 microg/ml after 20 min incubation in 2 M PG when compared to the control with 2.98 +/- 0.16 and 4.14 +/- 0.42 microg/ml respectively. Normalized ATP content for sperm sacs of two different gorgonian coral after incubation in methanol, DMSO, PG, EG and glycerol showed that J. juncea sperm sacs were slightly less tolerant to CPAs compared to J. fragilis sperm sacs. DMSO or methanol can be considered as efficient CPAs for gorgonian sperm sacs cryopreservation. The ATP luminescence assay provided sensitive and rapid quantification of mitochondrial activity in gorgonian coral sperm sacs. The study on the impact of CPA will contribute to the development of a

  12. 78 FR 16806 - The Commercial Mobile Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-19

    ... FEDERAL COMMUNICATIONS COMMISSION 47 CFR Part 10 [PS Docket No. 07-287; DA 13-280] The Commercial Mobile Alert System AGENCY: Federal Communications Commission. ACTION: Final rule. SUMMARY: In this document, the Commission amends its rules to change the name of the Commercial Mobile Alert System (CMAS...

  13. Distal Regeneration Involves the Age Dependent Activity of Branchial Sac Stem Cells in the Ascidian Ciona intestinalis.

    PubMed

    Jeffery, William R

    2015-02-01

    Tunicates have high capacities for regeneration but the underlying mechanisms and their relationship to life cycle progression are not well understood. Here we investigate the regeneration of distal structures in the ascidian tunicate Ciona intestinalis . Analysis of regenerative potential along the proximal-distal body axis indicated that distal organs, such as the siphons, their pigmented sensory organs, and the neural complex, could only be replaced from body fragments containing the branchial sac. Distal regeneration involves the formation of a blastema composed of cells that undergo cell proliferation prior to differentiation and cells that differentiate without cell proliferation. Both cell types originate in the branchial sac and appear in the blastema at different times after distal injury. Whereas the branchial sac stem cells are present in young animals, they are depleted in old animals that have lost their regeneration capacity. Thus Ciona adults contain a population of age-related stem cells located in the branchial sac that are a source of precursors for distal body regeneration.

  14. Experimental evaluation of candidate graphical microburst alert displays

    NASA Technical Reports Server (NTRS)

    Wanke, Craig R.; Hansman, R. John

    1992-01-01

    A piloted flight simulator experiment was conducted to evaluate issues related to the display of microburst alerts on electronic cockpit instrumentation. Issues addressed include display clarity, usefulness of multilevel microburst intensity information, and whether information from multiple sensors should be presented separately or 'fused' into combined alerts. Nine active airline pilots of 'glass cockpit' aircraft participated in the study. Microburst alerts presented on a moving map display were found to be visually clear and useful to pilots. Also, multilevel intensity information coded by colors or patterns was found to be important for decision making purposes. Pilot opinion was mixed on whether to 'fuse' data from multiple sensors, and some resulting design tradeoffs were identified. The positional information included in the graphical alert presentation was found useful by the pilots for planning lateral missed approach maneuvers, but may result in deviations which could interfere with normal airport operations. A number of flight crew training issues were also identified.

  15. SacLab: A toolbox for saccade analysis to increase usability of eye tracking systems in clinical ophthalmology practice.

    PubMed

    Cercenelli, Laura; Tiberi, Guido; Corazza, Ivan; Giannaccare, Giuseppe; Fresina, Michela; Marcelli, Emanuela

    2017-01-01

    Many open source software packages have been recently developed to expand the usability of eye tracking systems to study oculomotor behavior, but none of these is specifically designed to encompass all the main functions required for creating eye tracking tests and for providing the automatic analysis of saccadic eye movements. The aim of this study is to introduce SacLab, an intuitive, freely-available MATLAB toolbox based on Graphical User Interfaces (GUIs) that we have developed to increase the usability of the ViewPoint EyeTracker (Arrington Research, Scottsdale, AZ, USA) in clinical ophthalmology practice. SacLab consists of four processing modules that enable the user to easily create visual stimuli tests (Test Designer), record saccadic eye movements (Data Recorder), analyze the recorded data to automatically extract saccadic parameters of clinical interest (Data Analyzer) and provide an aggregate analysis from multiple eye movements recordings (Saccade Analyzer), without requiring any programming effort by the user. A demo application of SacLab to carry out eye tracking tests for the analysis of horizontal saccades was reported. We tested the usability of SacLab toolbox with three ophthalmologists who had no programming experience; the ophthalmologists were briefly trained in the use of SacLab GUIs and were asked to perform the demo application. The toolbox gained an enthusiastic feedback from all the clinicians in terms of intuitiveness, ease of use and flexibility. Test creation and data processing were accomplished in 52±21s and 46±19s, respectively, using the SacLab GUIs. SacLab may represent a useful tool to ease the application of the ViewPoint EyeTracker system in clinical routine in ophthalmology. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Stretch induced endothelin-1 secretion by adult rat astrocytes involves calcium influx via stretch-activated ion channels (SACs)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ostrow, Lyle W., E-mail: lostrow1@jhmi.edu; Suchyna, Thomas M.; Sachs, Frederick

    2011-06-24

    Highlights: {yields} Endothelin-1 expression by adult rat astrocytes correlates with cell proliferation. {yields} Stretch-induced ET-1 is inhibited by GsMtx-4, a specific inhibitor of Ca{sup 2+} permeant SACs. {yields} The less specific SAC inhibitor streptomycin also inhibits ET-1 secretion. {yields} Stretch-induced ET-1 production depends on a calcium influx. {yields} SAC pharmacology may provide a new class of therapeutic agents for CNS pathology. -- Abstract: The expression of endothelins (ETs) and ET-receptors is often upregulated in brain pathology. ET-1, a potent vasoconstrictor, also inhibits the expression of astrocyte glutamate transporters and is mitogenic for astrocytes, glioma cells, neurons, and brain capillary endothelia.more » We have previously shown that mechanical stress stimulates ET-1 production by adult rat astrocytes. We now show in adult astrocytes that ET-1 production is driven by calcium influx through stretch-activated ion channels (SACs) and the ET-1 production correlates with cell proliferation. Mechanical stimulation using biaxial stretch (<20%) of a rubber substrate increased ET-1 secretion, and 4 {mu}M GsMTx-4 (a specific inhibitor of SACs) inhibited secretion by 30%. GsMTx-4 did not alter basal ET-1 levels in the absence of stretch. Decreasing the calcium influx by lowering extracellular calcium also inhibited stretch-induced ET-1 secretion without effecting ET-1 secretion in unstretched controls. Furthermore, inhibiting SACs with the less specific inhibitor streptomycin also inhibited stretch-induced ET-1 secretion. The data can be explained with a simple model in which ET-1 secretion depends on an internal Ca{sup 2+} threshold. This coupling of mechanical stress to the astrocyte endothelin system through SACs has treatment implications, since all pathology deforms the surrounding parenchyma.« less

  17. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting.

    PubMed

    Harrison, Andrew M; Thongprayoon, Charat; Aakre, Christopher A; Jeng, Jack Y; Dziadzko, Mikhail A; Gajic, Ognjen; Pickering, Brian W; Herasevich, Vitaly

    2017-01-01

    Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. The alert acknowledgement rate from the severe sepsis alert system was 3% ( N  = 148) and 51% ( N  = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min ( N  = 5) and median 2 min ( N  = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting.

  18. Comparison of methods of alert acknowledgement by critical care clinicians in the ICU setting

    PubMed Central

    Harrison, Andrew M.; Thongprayoon, Charat; Aakre, Christopher A.; Jeng, Jack Y.; Dziadzko, Mikhail A.; Gajic, Ognjen; Pickering, Brian W.

    2017-01-01

    Background Electronic Health Record (EHR)-based sepsis alert systems have failed to demonstrate improvements in clinically meaningful endpoints. However, the effect of implementation barriers on the success of new sepsis alert systems is rarely explored. Objective To test the hypothesis time to severe sepsis alert acknowledgement by critical care clinicians in the ICU setting would be reduced using an EHR-based alert acknowledgement system compared to a text paging-based system. Study Design In one arm of this simulation study, real alerts for patients in the medical ICU were delivered to critical care clinicians through the EHR. In the other arm, simulated alerts were delivered through text paging. The primary outcome was time to alert acknowledgement. The secondary outcomes were a structured, mixed quantitative/qualitative survey and informal group interview. Results The alert acknowledgement rate from the severe sepsis alert system was 3% (N = 148) and 51% (N = 156) from simulated severe sepsis alerts through traditional text paging. Time to alert acknowledgement from the severe sepsis alert system was median 274 min (N = 5) and median 2 min (N = 80) from text paging. The response rate from the EHR-based alert system was insufficient to compare primary measures. However, secondary measures revealed important barriers. Conclusion Alert fatigue, interruption, human error, and information overload are barriers to alert and simulation studies in the ICU setting. PMID:28316887

  19. Alertness management in two-person long-haul flight operations

    NASA Technical Reports Server (NTRS)

    Rosekind, M. R.; Gander, P. H.

    1992-01-01

    Long-haul flight operations involve cumulative sleep loss, circadian disruption, and extended and irregular duty schedules. These factors reduce pilot alertness and performance on the flightdeck. Conceptually and operationally, alertness management in flight operations can be divided into preventive strategies and operational countermeasures. Preventive strategies are utilized prior to a duty period to mitigate or reduce the effects of sleep loss, circadian disruption and fatigue during subsequent flight operations. Operational countermeasures are used during operations as acute techniques for maintaining performance and alertness. Results from previous NASA Ames field studies document the sleep loss and circadian disruption in three-person long-haul flying and illustrate the application of preventive strategies and operational countermeasures. One strategy that can be used in both a preventive and operational manner is strategic napping. The application and effectiveness of strategic napping in long-haul operations will be discussed. Finally, long-haul flying in two-person highly automated aircraft capable of extended range operations will create new challenges to maintaining pilot alertness and performance. Alertness management issues in this flight environment will be explored.

  20. Bone histological correlates for air sacs and their implications for understanding the origin of the dinosaurian respiratory system.

    PubMed

    Lambertz, Markus; Bertozzo, Filippo; Sander, P Martin

    2018-01-01

    Air sacs are an important component of the avian respiratory system, and corresponding structures also were crucial for the evolution of sauropod dinosaur gigantism. Inferring the presence of air sacs in fossils so far is restricted to bones preserving internal pneumatic cavities and foramina as osteological correlates. We here present bone histological correlates for air sacs as a new potential identification tool for these elements of the respiratory system. The analysis of several avian and non-avian dinosaur samples revealed delicate fibres in secondary trabecular and secondary endosteal bone that in the former case (birds) is known or in the latter (non-avian dinosaurs) assumed to have been in contact with air sacs, respectively. The bone histology of this 'pneumosteal tissue' is markedly different from those regions where muscles attached presenting classical Sharpey's fibres. The pneumatized bones of several non-dinosaurian taxa do not exhibit the characteristics of this 'pneumosteum'. Our new histology-based approach thus can be instrumental in reconstructing the origin of air sacs among dinosaurs and hence for our understanding of this remarkable evolutionary novelty of the respiratory system. © 2018 The Author(s).

  1. Education and Training Module in Alertness Management

    NASA Technical Reports Server (NTRS)

    Mallis, M. M.; Brandt, S. L.; Oyung, R. L.; Reduta, D. D.; Rosekind, M. R.

    2006-01-01

    The education and training module (ETM) in alertness management has now been integrated as part of the training regimen of the Pilot Proficiency Awards Program ("WINGS") of the Federal Aviation Administration. Originated and now maintained current by the Fatigue Countermeasures Group at NASA Ames Research Center, the ETM in Alertness Management is designed to give pilots the benefit of the best and most recent research on the basics of sleep physiology, the causes of fatigue, and strategies for managing alertness during flight operations. The WINGS program is an incentive program that encourages pilots at all licensing levels to participate in recurrent training, upon completion of which distinctive lapel or tie pins (wings) and certificates of completion are awarded. In addition to flight training, all WINGS applicants must attend at least one FAA-sponsored safety seminar, FAA-sanctioned safety seminar, or industry recurrent training program. The Fatigue Countermeasures Group provides an FAA-approved industry recurrent training program through an on-line General Aviation (GA) WINGS ETM in alertness management to satisfy this requirement. Since 1993, the Fatigue Countermeasures Group has translated fatigue and alertness information to operational environments by conducting two-day ETM workshops oriented primarily toward air-carrier operations subject to Part 121 of the Federal Aviation Regulations pertaining to such operations. On the basis of the information presented in the two-day ETM workshops, an ETM was created for GA pilots and was transferred to a Web-based version. To comply with the requirements of the WINGS Program, the original Web-based version has been modified to include hypertext markup language (HTML) content that makes information easily accessible, in-depth testing of alertness-management knowledge, new interactive features, and increased informational resources for GA pilots. Upon successful completion of this training module, a participant

  2. On the origin of avian air sacs.

    PubMed

    Farmer, C G

    2006-11-01

    For many vertebrates the lung is the largest and lightest organ in the body cavity and for these reasons can greatly affect an organism's shape, density, and its distribution of mass; characters that are important to locomotion. In this paper non-respiratory functions of the lung are considered along with data on the respiratory capacities and gas exchange abilities of birds and crocodilians to infer the evolutionary history of the respiratory systems of dinosaurs, including birds. From a quadrupedal ancestry theropod dinosaurs evolved a bipedal posture. Bipedalism is an impressive balancing act, especially for tall animals with massive heads. During this transition selection for good balance and agility may have helped shape pulmonary morphology. Respiratory adaptations arising for bipedalism are suggested to include a reduction in costal ventilation and the use of cuirassal ventilation with a caudad expansion of the lung into the dorsal abdominal cavity. The evolution of volant animals from bipeds required yet again a major reorganization in body form. With this transition avian air sacs may have been favored because they enhanced balance and agility in flight. Finally, I propose that these hypotheses can be tested by examining the importance of the air sacs to balance and agility in extant animals and that these data will enhance our understanding of the evolution of the respiratory system in archosaurs.

  3. Malignant anal sac melanoma in dogs: eleven cases (2000 to 2015).

    PubMed

    Vinayak, A; Frank, C B; Gardiner, D W; Thieman-Mankin, K M; Worley, D R

    2017-04-01

    To report the signalment, clinical presentation, treatments pursued and outcomes of dogs with malignant anal sac melanoma. Medical records from five institutions from January 2000 through December 2015 were reviewed and dogs with cytologically- or histologically-confirmed malignant anal sac melanoma were identified. Signalment, clinical signs, staging, cytology, histopathologic analysis, surgical and non-surgical treatments were extracted from the medical records. The referring veterinarians and owners were contacted for follow-up data. Eleven dogs were included and survival data was available for all. The most common clinical signs were bloody anal sac discharge and perianal licking. Initial treatments pursued included surgery (n=8), chemotherapy (n=1), and palliative treatment with pain medications and stool softeners (n=2). In an adjuvant setting, melanoma vaccine was pursued following surgery in three dogs and chemotherapy in one dog. Regardless of treatment, progression-free survival (mean 92 · 5 days) and overall survival times (median 107 days) were short. Dogs in this case series had a guarded to poor prognosis regardless of treatment. Ten of 11 dogs were euthanased due to local or distant disease progression. Only 1 of 11 dogs was alive one year after diagnosis. An understanding of tumour behaviour in this location could lead to improved survival times with earlier diagnosis and treatment. © 2017 British Small Animal Veterinary Association.

  4. An Evaluation of Alert Services: Quantity versus Quality

    ERIC Educational Resources Information Center

    Zandian, Fatemeh; Riahinia, Nosrat; Azimi, Ali; Poursalehi, Nastaran

    2010-01-01

    Purpose: Online information vendors currently offer a variety of additional services; among these are alert services which present requested information on recent publications to registered users. This paper aims to investigate a variety of alert services provided by four online information vendors. Design/methodology/approach: A comparison of the…

  5. [Detection of Brucella with an automatic hemoculture system: Bact/Alert].

    PubMed

    Casas, J; Partal, Y; Llosá, J; Leiva, J; Navarro, J M; de la Rosa, M

    1994-12-01

    The ability of in vitro and in vivo detection of Brucella spp. with the Bact/Alert system was studied. Three strains of Brucella melitensis and two of Brucella abortus were used. Different dilutions of the five strains were performed in trypticase soy broth (TSB), achieving concentrations of 1 cfu/ml, 5 cfu/ml, 10 cfu/ml and 100 cfu/ml. Ten ml of each dilution and strain were inoculated into 5 aerobic bottles Bact/Alert and 5 biphasic Hemóline bottles. Furthermore, over a 9 month period, 8,216 bottles of Bact/Alert bottles from hospitalized patients and from the emergency department were processed in the authors' laboratory. The mean detection time for Brucella growth was from 2 to 3 days with the Bact/Alert system, and 14 days in the biphasic bottles. Former bottles processed in the authors' laboratory, 11 aerobic bottles belonged to 5 patients in whom brucelosis was confirmed by bloodculture. The Bact/Alert system detected Brucella melitensis in only on bottle at 2.9 days of incubation. In 7 bottles Bact/Alert detected B. melitensis by a blind pass of these bottles at 10 to 20 days of incubation. These results suggest that the Bact/Alert system does not totally solve the diagnosis of brucellosis. Blind passes of the bloodcultures are required.

  6. The agile alert system for gamma-ray transients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.

    2014-01-20

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a newmore » algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.« less

  7. The AGILE Alert System for Gamma-Ray Transients

    NASA Astrophysics Data System (ADS)

    Bulgarelli, A.; Trifoglio, M.; Gianotti, F.; Tavani, M.; Parmiggiani, N.; Fioretti, V.; Chen, A. W.; Vercellone, S.; Pittori, C.; Verrecchia, F.; Lucarelli, F.; Santolamazza, P.; Fanari, G.; Giommi, P.; Beneventano, D.; Argan, A.; Trois, A.; Scalise, E.; Longo, F.; Pellizzoni, A.; Pucella, G.; Colafrancesco, S.; Conforti, V.; Tempesta, P.; Cerone, M.; Sabatini, P.; Annoni, G.; Valentini, G.; Salotti, L.

    2014-01-01

    In recent years, a new generation of space missions has offered great opportunities for discovery in high-energy astrophysics. In this article we focus on the scientific operations of the Gamma-Ray Imaging Detector (GRID) on board the AGILE space mission. AGILE-GRID, sensitive in the energy range of 30 MeV-30 GeV, has detected many γ-ray transients of both galactic and extragalactic origin. This work presents the AGILE innovative approach to fast γ-ray transient detection, which is a challenging task and a crucial part of the AGILE scientific program. The goals are to describe (1) the AGILE Gamma-Ray Alert System, (2) a new algorithm for blind search identification of transients within a short processing time, (3) the AGILE procedure for γ-ray transient alert management, and (4) the likelihood of ratio tests that are necessary to evaluate the post-trial statistical significance of the results. Special algorithms and an optimized sequence of tasks are necessary to reach our goal. Data are automatically analyzed at every orbital downlink by an alert pipeline operating on different timescales. As proper flux thresholds are exceeded, alerts are automatically generated and sent as SMS messages to cellular telephones, via e-mail, and via push notifications from an application for smartphones and tablets. These alerts are crosschecked with the results of two pipelines, and a manual analysis is performed. Being a small scientific-class mission, AGILE is characterized by optimization of both scientific analysis and ground-segment resources. The system is capable of generating alerts within two to three hours of a data downlink, an unprecedented reaction time in γ-ray astrophysics.

  8. Low-lying π∗ resonances associated with cyano groups: A CAP/SAC-CI study

    NASA Astrophysics Data System (ADS)

    Ehara, Masahiro; Kanazawa, Yuki; Sommerfeld, Thomas

    2017-01-01

    The complex absorbing potential (CAP)/symmetry-adapted cluster-configuration interaction (SAC-CI) method is applied to low-lying π∗ resonance states of molecules containing one or two cyano (CN) groups. Benchmark calculations are carried out comparing the non-variational and approximate variational approach of SAC-CI and studying the selection threshold of operators. Experimental resonance positions from electron transmission spectroscopy (ETS) are reproduced provided the anticipated deviations due to vibronic effects are taken into account. Moreover, the calculated positions and widths agree well with those obtained in previous electron scattering calculations for HCN, CH3CN and their isonitriles. Based on our results, we suggest a reassignment of the experimental ETS of fumaronitrile and malononitrile. Our present results demonstrate again that the CAP/SAC-CI method reliably predicts low-lying π∗ resonances, and regarding the total numbers of molecules and resonances investigated, it is fair to say that it is presently the most extensively used high-level method in the temporary anion field.

  9. Collaborative knowledge acquisition for the design of context-aware alert systems.

    PubMed

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L; Bernstam, Elmer Victor

    2012-01-01

    To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Five internal medicine residents reviewed 18 anemia alerts, while 'talking aloud'. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules.

  10. Analysis of UAS DAA Alerting in Fast-Time Simulations without DAA Mitigation

    NASA Technical Reports Server (NTRS)

    Thipphavong, David P.; Santiago, Confesor; Isaacson, Douglas R.; Lee, Seung Man; Park, Chunki; Refai, Mohamad Said; Snow, James

    2015-01-01

    Realization of the expected proliferation of Unmanned Aircraft System (UAS) operations in the National Airspace System (NAS) depends on the development and validation of performance standards for UAS Detect and Avoid (DAA) Systems. The RTCA Special Committee 228 is charged with leading the development of draft Minimum Operational Performance Standards (MOPS) for UAS DAA Systems. NASA, as a participating member of RTCA SC-228 is committed to supporting the development and validation of draft requirements for DAA alerting system performance. A recent study conducted using NASA's ACES (Airspace Concept Evaluation System) simulation capability begins to address questions surrounding the development of draft MOPS for DAA alerting systems. ACES simulations were conducted to study the performance of alerting systems proposed by the SC-228 DAA Alerting sub-group. Analysis included but was not limited to: 1) correct alert (and timeliness), 2) false alert (and severity and duration), 3) missed alert, and 4) probability of an alert type at the time of loss of well clear. The performance of DAA alerting systems when using intent vs. dead-reckoning for UAS ownship trajectories was also compared. The results will be used by SC-228 to inform decisions about the surveillance standards of UAS DAA systems and future requirements development and validation efforts.

  11. Static Analysis Alert Audits: Lexicon and Rules

    DTIC Science & Technology

    2016-11-04

    collaborators • Includes a standard set of well-defined determinations for static analysis alerts • Includes a set of auditing rules to help auditors make...consistent decisions in commonly-encountered situations Different auditors should make the same determination for a given alert! Improve the quality and...scenarios • Establish assumptions auditors can make • Overall: help make audit determinations more consistent We developed 12 rules • Drew on our own

  12. Torsion of an Indirect Hernia Sac Causing Acute Scrotal Swelling in a Child

    PubMed Central

    Ahn, Jae Hyun; Kim, Hyeon Woo; Park, Hyun Jun; Lee, Sang Don; Chung, Moon Kee

    2012-01-01

    Torsion of a hernia sac is an extremely rare condition that presents as acute scrotum in children. We report a case of a 6-year-old boy who presented with an acute scrotum and was found during surgical exploration to have torsion of an indirect hernia sac associated with hydrocele. Upon scrotal exploration, deterioration of the scrotum due to inflammatory changes was found. A necrotic cyst was recognized within a communicating hydrocele of the scrotum and was twisted at an angle of about 360°. All urologists should be aware of this special condition in the differential diagnosis of acute scrotum. PMID:23596604

  13. Skylab short-lived event alert program

    NASA Technical Reports Server (NTRS)

    Citron, R. A.

    1974-01-01

    During the three manned Skylab missions, the Center for Short-Lived Phenomena (CSLP) reported a total of 39 significant events to the Johnson Space Center (JSC) as part of the Skylab Short-Lived Event Alert Program. The telegraphed daily status reports included the names and locations of the events, the track number and revolution number during which the event could be observed, the time (GMT) to within plus or minus 2 sec when Skylab was closest to the event area, and the light condition (daylight or darkness) at that time and place. The messages sent to JSC during the Skylab 4 mission also included information pertaining to ground-truth studies and observations being conducted on the events. Photographic priorities were assigned for each event.

  14. A Case of Recurrent Schneiderian Papilloma of the Lacrimal Sac Invading the Nasal Cavity

    PubMed Central

    Jang, Ji Hye; Choe, Mi Sun

    2009-01-01

    A 44-year-old man presented with a history of chronic epiphora, discharge from the right eye, and a palpable mass in the medial canthal area. Irrigation of the lacrimal system revealed bloody discharge. Orbital magnetic resonance imaging (MRI) showed a well-defined heterogeneous enhanced mass filling the lacrimal sac and upper nasolacrimal duct (NLD). A wide excision and surgical biopsy were performed. Histopathology showed the tumor to be an exophytic Schneiderian papilloma with moderate to severe dysplasia. Three months later, the mass was found to be invading the nasal cavity through the NLD. Endoscopic histopathological evaluation confirmed that it was identical to the originally identified papilloma. PMID:19568358

  15. R&D Alert. Volume 7, Number 2, 2005

    ERIC Educational Resources Information Center

    White, Noel, Ed.

    2005-01-01

    "R&D Alert" covers issues affecting schools in the Western Regional Educational Laboratory's four-state region--Arizona, California, Nevada, and Utah--and throughout the United States. This issue of "R&D Alert" shares what WestEd is learning from a sample of their latest work, focusing on three points in the process:…

  16. Gestational sac and embryonic growth are not useful as criteria to define miscarriage: a multicenter observational study.

    PubMed

    Abdallah, Y; Daemen, A; Guha, S; Syed, S; Naji, O; Pexsters, A; Kirk, E; Stalder, C; Gould, D; Ahmed, S; Bottomley, C; Timmerman, D; Bourne, T

    2011-11-01

    We studied changes in mean gestational sac diameter (MSD) and embryonic crown-rump length (CRL) in intrauterine pregnancies of uncertain viability (IPUVs). We aimed to establish cut-off values for MSD and CRL growth that could be definitively associated with either viability or miscarriage, and to establish the relationship between growth in MSD and appearance of embryonic structures in the gestational sac. One thousand and sixty consecutive IPUVs were recruited prospectively from four London University hospitals: 462 with no yolk sac or embryo, 419 with a yolk sac but no embryo, and 179 with an embryo but no heartbeat visible. IPUV was defined as an empty gestational sac with or without a yolk sac but no embryo seen with MSD < 20 or < 30 mm (depending on center) or an embryo with no heartbeat and CRL < 6 mm or < 8 mm (depending on center). Scans were repeated 7-14 days later. The endpoint was viability at first-trimester screening ultrasonography between 11 and 14 weeks. Change in MSD and CRL between the first and second scans of each pregnancy was compared with respect to viability and appearance of embryonic structures using the two-sample t-test. The study included 359 pregnancies in which a gestational sac with or without embryo was identified at the follow-up scan 7-14 days later. Of these, 192 were viable and 167 non-viable at the 11-14-week scan. MSD growth was significantly higher in viable than non-viable pregnancies (mean 1.003 vs. 0.503 mm/day; P < 0.001, 95% CI of difference 0.403-0.596). A difference in CRL growth was found between the two groups (mean 0.673 vs. 0.148 mm/day; P < 0.001, 95% CI of difference 0.345-0.703). MSD growth of 0.6 mm/day was associated with a specificity for diagnosing miscarriage of 90.1%, a sensitivity of 61.7% and 19 false-positive test results. A cut-off of CRL growth rate of 0.2 mm/day gave a sensitivity of 76.3% and there were no false-positive test results for miscarriage. On repeat scan the failure of either a yolk sac

  17. Pleiotropic Alterations in Lipid Metabolism in Yeast sac1 Mutants: Relationship to “Bypass Sec14p” and Inositol Auxotrophy

    PubMed Central

    Rivas, Marcos P.; Kearns, Brian G.; Xie, Zhigang; Guo, Shuling; Sekar, M. Chandra; Hosaka, Kohei; Kagiwada, Satoshi; York, John D.; Bankaitis, Vytas A.

    1999-01-01

    SacIp dysfunction results in bypass of the requirement for phosphatidylinositol transfer protein (Sec14p) function in yeast Golgi processes. This effect is accompanied by alterations in inositol phospholipid metabolism and inositol auxotrophy. Elucidation of how sac1 mutants effect “bypass Sec14p” will provide insights into Sec14p function in vivo. We now report that, in addition to a dramatic accumulation of phosphatidylinositol-4-phosphate, sac1 mutants also exhibit a specific acceleration of phosphatidylcholine biosynthesis via the CDP-choline pathway. This phosphatidylcholine metabolic phenotype is sensitive to the two physiological challenges that abolish bypass Sec14p in sac1 strains; i.e. phospholipase D inactivation and expression of bacterial diacylglycerol (DAG) kinase. Moreover, we demonstrate that accumulation of phosphatidylinositol-4-phosphate in sac1 mutants is insufficient to effect bypass Sec14p. These data support a model in which phospholipase D activity contributes to generation of DAG that, in turn, effects bypass Sec14p. A significant fate for this DAG is consumption by the CDP-choline pathway. Finally, we determine that CDP-choline pathway activity contributes to the inositol auxotrophy of sac1 strains in a novel manner that does not involve obvious defects in transcriptional expression of the INO1 gene. PMID:10397762

  18. Changes in endolymphatic hydrops visualized by magnetic resonance imaging after sac surgery.

    PubMed

    Zhang, Yuan; Cui, Yong-Hua; Hu, Ying; Mao, Zhong-Yao; Wang, Qiu-Xia; Pan, Chu; Liu, Ai-Guo

    2016-10-01

    The purpose of the study was to observe changes in endolymphatic hydrops by using intratympanic injection of gadolinium and magnetic resonance imaging (MRI) before and after endolymphatic sac surgery in patients with unilateral Meniere's disease. Thirteen patients with unilateral Meniere's disease undergoing endolymphatic sac surgery were retrospectively and prospectively analyzed. Three-dimensional fluid-attenuated inversion recovery or three-dimensional real inversion recovery MRI was performed 24 h after an intratympanic injection of gadolinium to grade the presence of endolymphatic hydrops. Among the 13 patients with hydrops confirmed by preoperative MRI, vestibular hydrops had no significant change in all patients; cochlear hydrops became negative in 2 patients, and remained unchanged in the other 11 patients after surgery. Definite vertigo attacks were substantially controlled in one patient and completely controlled in 12 patients during a follow-up period of 8-34 months after surgery. The hearing levels were improved in 3 patients, remained unchanged in 7 patients, and decreased in 3 patients. In conclusion, endolymphatic sac surgery does not always alleviate endolymphatic hydrops in patients with Meniere's disease. Relief from vertigo cannot always be attributed to the remission of hydrops. A change in hearing levels cannot be explained by hydrops status alone.

  19. Pilot evaluation of a method to assess prescribers' information processing of medication alerts.

    PubMed

    Russ, Alissa L; Melton, Brittany L; Daggy, Joanne K; Saleem, Jason J

    2017-02-01

    Prescribers commonly receive alerts during medication ordering. Prescribers work in a complex, time-pressured environment; to enhance the effectiveness of safety alerts, the effort needed to cognitively process these alerts should be minimized. Methods to evaluate the extent to which computerized alerts support prescribers' information processing are lacking. To develop a methodological protocol to assess the extent to which alerts support prescribers' information processing at-a-glance; specifically, the incorporation of information into their working memory. We hypothesized that the method would be feasible and that we would be able to detect a significant difference in prescribers' information processing with a revised alert display that incorporates warning design guidelines compared to the original alert display. A counterbalanced, within-subject study was conducted with 20 prescribers in a human-computer interaction laboratory. We tested a single alert that was displayed in two different ways. Prescribers were informed that an alert would appear for 10s. After the alert was shown, a white screen was displayed, and prescribers were asked to verbally describe what they saw; indicate how many total warnings; and describe anything else they remembered about the alert. We measured information processing via the accuracy of prescribers' free recall and their ability to identify that three warning messages were present. Two analysts independently evaluated participants' responses against a comprehensive catalog of alert elements and then discussed discrepancies until reaching consensus. This feasibility study demonstrated that the method seemed to be effective for evaluating prescribers' information processing of medication alert displays. With this method, we were able to detect significant differences in prescribers' recall of alert information. The proportion of total data elements that prescribers were able to accurately recall was significantly greater for the

  20. Tracking wakefulness as it fades: Micro-measures of alertness.

    PubMed

    Jagannathan, Sridhar R; Ezquerro-Nassar, Alejandro; Jachs, Barbara; Pustovaya, Olga V; Bareham, Corinne A; Bekinschtein, Tristan A

    2018-08-01

    A major problem in psychology and physiology experiments is drowsiness: around a third of participants show decreased wakefulness despite being instructed to stay alert. In some non-visual experiments participants keep their eyes closed throughout the task, thus promoting the occurrence of such periods of varying alertness. These wakefulness changes contribute to systematic noise in data and measures of interest. To account for this omnipresent problem in data acquisition we defined criteria and code to allow researchers to detect and control for varying alertness in electroencephalography (EEG) experiments under eyes-closed settings. We first revise a visual-scoring method developed for detection and characterization of the sleep-onset process, and adapt the same for detection of alertness levels. Furthermore, we show the major issues preventing the practical use of this method, and overcome these issues by developing an automated method (micro-measures algorithm) based on frequency and sleep graphoelements, which are capable of detecting micro variations in alertness. The validity of the micro-measures algorithm was verified by training and testing using a dataset where participants are known to fall asleep. In addition, we tested generalisability by independent validation on another dataset. The methods developed constitute a unique tool to assess micro variations in levels of alertness and control trial-by-trial retrospectively or prospectively in every experiment performed with EEG in cognitive neuroscience under eyes-closed settings. Copyright © 2018. Published by Elsevier Inc.

  1. Self-Alert Training: Volitional Modulation of Autonomic Arousal Improves Sustained Attention

    ERIC Educational Resources Information Center

    O'Connell, Redmond G.; Bellgrove, Mark A.; Dockree, Paul M.; Lau, Adam; Fitzgerald, Michael; Robertson, Ian H.

    2008-01-01

    The present study examines a new alertness training strategy (Self-Alert Training, SAT) designed to explore the relationship between the top-down control processes governing arousal and sustained attention. In order to maximally target frontal control systems SAT combines a previously validated behavioural self-alerting technique [Robertson, I.…

  2. Collaborative knowledge acquisition for the design of context-aware alert systems

    PubMed Central

    Joffe, Erel; Havakuk, Ofer; Herskovic, Jorge R; Patel, Vimla L

    2012-01-01

    Objective To present a framework for combining implicit knowledge acquisition from multiple experts with machine learning and to evaluate this framework in the context of anemia alerts. Materials and Methods Five internal medicine residents reviewed 18 anemia alerts, while ‘talking aloud’. They identified features that were reviewed by two or more physicians to determine appropriate alert level, etiology and treatment recommendation. Based on these features, data were extracted from 100 randomly-selected anemia cases for a training set and an additional 82 cases for a test set. Two staff internists assigned an alert level, etiology and treatment recommendation before and after reviewing the entire electronic medical record. The training set of 118 cases (100 plus 18) and the test set of 82 cases were explored using RIDOR and JRip algorithms. Results The feature set was sufficient to assess 93% of anemia cases (intraclass correlation for alert level before and after review of the records by internists 1 and 2 were 0.92 and 0.95, respectively). High-precision classifiers were constructed to identify low-level alerts (precision p=0.87, recall R=0.4), iron deficiency (p=1.0, R=0.73), and anemia associated with kidney disease (p=0.87, R=0.77). Discussion It was possible to identify low-level alerts and several conditions commonly associated with chronic anemia. This approach may reduce the number of clinically unimportant alerts. The study was limited to anemia alerts. Furthermore, clinicians were aware of the study hypotheses potentially biasing their evaluation. Conclusion Implicit knowledge acquisition, collaborative filtering and machine learning were combined automatically to induce clinically meaningful and precise decision rules. PMID:22744961

  3. Alerts Analysis and Visualization in Network-based Intrusion Detection Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Dr. Li

    2010-08-01

    The alerts produced by network-based intrusion detection systems, e.g. Snort, can be difficult for network administrators to efficiently review and respond to due to the enormous number of alerts generated in a short time frame. This work describes how the visualization of raw IDS alert data assists network administrators in understanding the current state of a network and quickens the process of reviewing and responding to intrusion attempts. The project presented in this work consists of three primary components. The first component provides a visual mapping of the network topology that allows the end-user to easily browse clustered alerts. Themore » second component is based on the flocking behavior of birds such that birds tend to follow other birds with similar behaviors. This component allows the end-user to see the clustering process and provides an efficient means for reviewing alert data. The third component discovers and visualizes patterns of multistage attacks by profiling the attacker s behaviors.« less

  4. Wireless clinical alerts and patient outcomes in the surgical intensive care unit.

    PubMed

    Major, Kevin; Shabot, M Michael; Cunneen, Scott

    2002-12-01

    Errors in medicine have gained public interest since the Institute of Medicine published its 1999 report on this subject. Although errors of commission are frequently cited, errors of omission can be equally serious. A computerized surgical intensive care unit (SICU) information system when coupled to an event-driven alerting engine has the potential to reduce errors of omission for critical intensive care unit events. Automated alerts and patient outcomes were prospectively collected for all patients admitted to a tertiary-care SICU for a 2-year period. During the study period 3,973 patients were admitted to the SICU and received 13,608 days of care. A total of 15,066 alert pages were sent including alerts for physiologic condition (6,163), laboratory data (4,951), blood gas (3,774), drug allergy (130), and toxic drug levels (48). Admission Simplified Acute Physiology Score and Acute Physiology and Chronic Health Evaluation II score, SICU lengths of stay, and overall mortality rates were significantly higher in patients who triggered the alerting system. Patients triggering the alert paging system were 49.4 times more likely to die in the SICU compared with patients who did not generate an alert. Even after transfer to floor care the patients who triggered the alerting system were 5.7 times more likely to die in the hospital. An alert page identifies patients who will stay in the SICU longer and have a significantly higher chance of death compared with patients who do not trigger the alerting system.

  5. An Investigation of Drug-Drug Interaction Alert Overrides at a Pediatric Hospital.

    PubMed

    Humphrey, Kate; Jorina, Maria; Harper, Marvin; Dodson, Brenda; Kim, Seung-Yeon; Ozonoff, Al

    2018-05-01

    Drug-drug interactions (DDIs) can result in patient harm. DDI alerts are intended to help prevent harm; when the majority of alerts presented to providers are being overridden, their value is diminished. Our objective was to evaluate the overall rates of DDI alert overrides and how rates varied by specialty, clinician type, and patient complexity. A retrospective study of DDI alert overrides that occurred during 2012 and 2013 within the inpatient setting described at the medication-, hospital-, provider-, and patient encounter-specific levels was performed at an urban, quaternary-care, pediatric hospital. There were >41 000 DDI alerts presented to clinicians; ∼90% were overridden. The 5 DDI pairs that were most frequently presented and overridden included the following: potassium chloride-spironolactone, methadone-ondansetron, ketorolac-ibuprofen, cyclosporine-fluconazole, and potassium chloride-enalapril, each with an alert override rate of ≥0.89. Override rates across provider groups ranged between 0.84 and 0.97. In general, patients with high complexity had a higher frequency of alert overrides, but the rates of alert overrides for each DDI pairing did not differ significantly. High rates of DDI alert overrides occur across medications, provider groups, and patient encounters. Methods to decrease DDI alerts which are likely to be overridden exist, but it is also clear that more robust and intelligent tools are needed. Characteristics exist at the medication, hospital, provider, and patient levels that can be used to help specialize and enhance information transmission. Copyright © 2018 by the American Academy of Pediatrics.

  6. Using Heuristic Evaluation to Improve Sepsis Alert Usability.

    PubMed

    Pertiwi, Ariani Arista Putri; Fraczkowski, Dan; Stogis, Sheryl L; Lopez, Karen Dunn

    2018-06-01

    Sepsis, life-threatening organ dysfunction in response to infection, is an alarmingly common and aggressive illness in US hospitals, especially for intensive care patients. Preventing sepsis deaths rests on the clinicians' ability to promptly recognize and treat sepsis. To aid early recognition, many organizations have employed clinician-facing electronic sepsis alert systems. However, the effectiveness of the alert relies on heavily on the visual interface, textual information, and overall usability. This article reports a usability inspection of a sepsis alert system. The authors found violations in 12 of the 14 usability principles and promote use of this method in practice to systematically identify usability problems. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Distal regeneration involves the age dependent activity of branchial sac stem cells in the ascidian Ciona intestinalis

    PubMed Central

    2014-01-01

    Abstract Tunicates have high capacities for regeneration but the underlying mechanisms and their relationship to life cycle progression are not well understood. Here we investigate the regeneration of distal structures in the ascidian tunicate Ciona intestinalis. Analysis of regenerative potential along the proximal−distal body axis indicated that distal organs, such as the siphons, their pigmented sensory organs, and the neural complex, could only be replaced from body fragments containing the branchial sac. Distal regeneration involves the formation of a blastema composed of cells that undergo cell proliferation prior to differentiation and cells that differentiate without cell proliferation. Both cell types originate in the branchial sac and appear in the blastema at different times after distal injury. Whereas the branchial sac stem cells are present in young animals, they are depleted in old animals that have lost their regeneration capacity. Thus Ciona adults contain a population of age‐related stem cells located in the branchial sac that are a source of precursors for distal body regeneration. PMID:25893097

  8. Reduced Effectiveness of Interruptive Drug-Drug Interaction Alerts after Conversion to a Commercial Electronic Health Record.

    PubMed

    Wright, Adam; Aaron, Skye; Seger, Diane L; Samal, Lipika; Schiff, Gordon D; Bates, David W

    2018-05-15

    Drug-drug interaction (DDI) alerts in electronic health records (EHRs) can help prevent adverse drug events, but such alerts are frequently overridden, raising concerns about their clinical usefulness and contribution to alert fatigue. To study the effect of conversion to a commercial EHR on DDI alert and acceptance rates. Two before-and-after studies. 3277 clinicians who received a DDI alert in the outpatient setting. Introduction of a new, commercial EHR and subsequent adjustment of DDI alerting criteria. Alert burden and proportion of alerts accepted. Overall interruptive DDI alert burden increased by a factor of 6 from the legacy EHR to the commercial EHR. The acceptance rate for the most severe alerts fell from 100 to 8.4%, and from 29.3 to 7.5% for medium severity alerts (P < 0.001). After disabling the least severe alerts, total DDI alert burden fell by 50.5%, and acceptance of Tier 1 alerts rose from 9.1 to 12.7% (P < 0.01). Changing from a highly tailored DDI alerting system to a more general one as part of an EHR conversion decreased acceptance of DDI alerts and increased alert burden on users. The decrease in acceptance rates cannot be fully explained by differences in the clinical knowledge base, nor can it be fully explained by alert fatigue associated with increased alert burden. Instead, workflow factors probably predominate, including timing of alerts in the prescribing process, lack of differentiation of more and less severe alerts, and features of how users interact with alerts.

  9. Lipids of the anal sac secretions of the red fox, Vulpes vulpes and of the lion, Panthera leo.

    PubMed

    Albone, E S; Grönnerberg, T O

    1977-07-01

    Lion anal sac secretion were found to be richer in lipids and to contain more complex less uniform mixtures of lower moleculas weight lipids then the anal sac of the red fox. In the lion, homologous series of 1-alkylglycerols and 2-hydroxy-fatty acids were identified. Phenylacetic, 3-phenylpropionic, and related hydroxylated acids were also observed. Gas-liquid chromatography profiles of fox anal sac secretion lower molecular weight lipids were found to be less variable in their major constituents and to be dominated by relatively few large peaks, mainly (derivatized) fatty acids. Indole was also identified. Free cholesterol, and occasionally, stanols were observed in fox and lion secretions. In the red fox, total cholesterol levels averaged 0.93 mg/g (% free, 56.4), n = 5. Findings are discussed in relation to histological and anatomical similarities and differences between the anal sacs of the lion and the fox and in the context of the role of these secretions in chemical communication.

  10. Regulatory alerts for dietary supplements in Canada and the United States, 2005-13.

    PubMed

    Abe, Andrew M; Hein, Darren J; Gregory, Philip J

    2015-06-01

    Dietary supplement regulatory alerts published by the Food and Drug Administration (FDA) and Health Canada were evaluated and characterized. FDA MedWatch and Health Canada websites were reviewed to identify regulatory alerts regarding dietary supplements from January 1, 2005, through December 31, 2013. Alerts were analyzed to identify product characteristics that may be predictive of product quality issues and potential patient harm. A total of 1560 dietary supplement-related regulatory alerts were identified. Of those, 1287 (83%) were identified through Health Canada, and 273 (18%) were identified through FDA MedWatch. The country of origin of dietary supplements associated with regulatory alerts was not provided in most regulatory alerts; however, when their origin was provided, the United States was the most common. Dietary supplements intended for sexual enhancement were the subject of 33% of all regulatory alerts identified. Products purchased online were the most likely to be associated with a regulatory alert. Dietary supplements intended for sexual enhancement, weight loss, and bodybuilding or athletic performance appeared to pose the greatest risk for patient harm due to product contamination with a pharmaceutical such as a phosphodiesterase-5 inhibitor or sibutramine. Analysis of Canadian and U.S. regulatory alerts concerning dietary supplements revealed that more than 80% of the composite alerts were issued by Health Canada. The most common intended uses of supplements for which alerts were issued were sexual enhancement, weight loss, and bodybuilding or athletic performance. The most common reason for alerts was the presence of a pharmaceutical contaminant. Copyright © 2015 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  11. The Student Actions Coding Sheet (SACS): An instrument for illuminating the shifts toward student-centered science classrooms

    NASA Astrophysics Data System (ADS)

    Erdogan, Ibrahim; Campbell, Todd; Hashidah Abd-Hamid, Nor

    2011-07-01

    This study describes the development of an instrument to investigate the extent to which student-centered actions are occurring in science classrooms. The instrument was developed through the following five stages: (1) student action identification, (2) use of both national and international content experts to establish content validity, (3) refinement of the item pool based on reviewer comments, (4) pilot testing of the instrument, and (5) statistical reliability and item analysis leading to additional refinement and finalization of the instrument. In the field test, the instrument consisted of 26 items separated into four categories originally derived from student-centered instruction literature and used by the authors to sort student actions in previous research. The SACS was administered across 22 Grade 6-8 classrooms by 22 groups of observers, with a total of 67 SACS ratings completed. The finalized instrument was found to be internally consistent, with acceptable estimates from inter-rater intraclass correlation reliability coefficients at the p < 0.01 level. After the final stage of development, the SACS instrument consisted of 24 items separated into three categories, which aligned with the factor analysis clustering of the items. Additionally, concurrent validity of the SACS was established with the Reformed Teaching Observation Protocol. Based on the analyses completed, the SACS appears to be a useful instrument for inclusion in comprehensive assessment packages for illuminating the extent to which student-centered actions are occurring in science classrooms.

  12. Practitioners’ Views on Computerized Drug–Drug Interaction Alerts in the VA System

    PubMed Central

    Ko, Yu; Abarca, Jacob; Malone, Daniel C.; Dare, Donna C.; Geraets, Doug; Houranieh, Antoun; Jones, William N.; Nichol, W. Paul; Schepers, Gregory P.; Wilhardt, Michelle

    2007-01-01

    Objectives To assess Veterans Affairs (VA) prescribers’ and pharmacists’ opinions about computer-generated drug–drug interaction (DDI) alerts and obtain suggestions for improving DDI alerts. Design A mail survey of 725 prescribers and 142 pharmacists from seven VA medical centers across the United States. Measurements A questionnaire asked respondents about their sources of drug and DDI information, satisfaction with the combined inpatient and outpatient computerized prescriber order entry (CPOE) system, attitude toward DDI alerts, and suggestions for improving DDI alerts. Results The overall response rate was 40% (prescribers: 36%; pharmacists: 59%). Both prescribers and pharmacists indicated that the CPOE system had a neutral to positive impact on their jobs. DDI alerts were not viewed as a waste of time and the majority (61%) of prescribers felt that DDI alerts had increased their potential to prescribe safely. However, only 30% of prescribers felt DDI alerts provided them with what they needed most of the time. Both prescribers and pharmacists agreed that DDI alerts should be accompanied by management alternatives (73% and 82%, respectively) and more detailed information (65% and 89%, respectively). When asked about suggestions for improving DDI alerts, prescribers most preferred including management options whereas pharmacists most preferred making it more difficult to override lethal interactions. Prescribers and pharmacists reported primarily relying on electronic references for general drug information (62% and 55%, respectively) and DDI information (51% and 79%, respectively). Conclusion Respondents reported neutral to positive views regarding the effect of CPOE on their jobs. Their opinions suggest DDI alerts are useful but still require additional work to increase their clinical utility. PMID:17068346

  13. Wide variation and patterns of physicians' responses to drug-drug interaction alerts.

    PubMed

    Cho, Insook; Lee, Yura; Lee, Jae-Ho; Bates, David W

    2018-05-08

    Providing physicians with alerts about potentially harmful drug-drug interactions (DDIs) is only moderately effective due to high alert override rates. To understand high override behavior on DDI alerts, we investigated how physicians respond to DDIs and their behavior patterns and variations. Retrospective system log data analysis and records review (sampling 2% of total overrides). A large tertiary academic hospital. About 560 physicians and their override responses to DDI alerts generated from 1 September to 31 December 2014. Not applicable. DDI alert frequency and override rate. We found significant variation in both the number of alerts and override rates at the levels of physicians, departments and drug-class pairs. Physician-level variations were wider for residents than for faculty staff (number of alerts: t = 254.17, P = 0.011; override rates: t = -4.77, P < 0.0001). Using the number of alerts and their override rate, we classified physicians into four groups: inexperienced incautious users, inexperienced cautious users, experienced cautious users and experienced incautious users. Medical department influenced both alert numbers and override rates. Nearly 90% of the overrides involved only five drug-class combinations, which had a wide range of appropriateness in the chart review. The variations at drug-class levels suggest issues with system design and the DDI rules. Department-level variation may be best addressed at the department level, and the rest of the variation appears related to individual physician responses, suggesting the need for interventions at an individual level.

  14. CISN ShakeAlert Earthquake Early Warning System Monitoring Tools

    NASA Astrophysics Data System (ADS)

    Henson, I. H.; Allen, R. M.; Neuhauser, D. S.

    2015-12-01

    CISN ShakeAlert is a prototype earthquake early warning system being developed and tested by the California Integrated Seismic Network. The system has recently been expanded to support redundant data processing and communications. It now runs on six machines at three locations with ten Apache ActiveMQ message brokers linking together 18 waveform processors, 12 event association processes and 4 Decision Module alert processes. The system ingests waveform data from about 500 stations and generates many thousands of triggers per day, from which a small portion produce earthquake alerts. We have developed interactive web browser system-monitoring tools that display near real time state-of-health and performance information. This includes station availability, trigger statistics, communication and alert latencies. Connections to regional earthquake catalogs provide a rapid assessment of the Decision Module hypocenter accuracy. Historical performance can be evaluated, including statistics for hypocenter and origin time accuracy and alert time latencies for different time periods, magnitude ranges and geographic regions. For the ElarmS event associator, individual earthquake processing histories can be examined, including details of the transmission and processing latencies associated with individual P-wave triggers. Individual station trigger and latency statistics are available. Detailed information about the ElarmS trigger association process for both alerted events and rejected events is also available. The Google Web Toolkit and Map API have been used to develop interactive web pages that link tabular and geographic information. Statistical analysis is provided by the R-Statistics System linked to a PostgreSQL database.

  15. Usability flaws of medication-related alerting functions: A systematic qualitative review.

    PubMed

    Marcilly, Romaric; Ammenwerth, Elske; Vasseur, Francis; Roehrer, Erin; Beuscart-Zéphir, Marie-Catherine

    2015-06-01

    Medication-related alerting functions may include usability flaws that limit their optimal use. A first step on the way to preventing usability flaws is to understand the characteristics of these usability flaws. This systematic qualitative review aims to analyze the type of usability flaws found in medication-related alerting functions. Papers were searched via PubMed, Scopus and Ergonomics Abstracts databases, along with references lists. Paper selection, data extraction and data analysis was performed by two to three Human Factors experts. Meaningful semantic units representing instances of usability flaws were the main data extracted. They were analyzed through qualitative methods: categorization following general usability heuristics and through an inductive process for the flaws specific to medication-related alerting functions. From the 6380 papers initially identified, 26 met all eligibility criteria. The analysis of the papers identified a total of 168 instances of usability flaws that could be classified into 13 categories of usability flaws representing either violations of general usability principles (i.e. they could be found in any system, e.g. guidance and workload issues) or infractions specific to medication-related alerting functions. The latter refer to issues of low signal-to-noise ratio, incomplete content of alerts, transparency, presentation mode and timing, missing alert features, tasks and control distribution. The list of 168 instances of usability flaws of medication-related alerting functions provides a source of knowledge for checking the usability of medication-related alerting functions during their design and evaluation process and ultimately constructs evidence-based usability design principles for these functions. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Determining Inappropriate Medication Alerts from "Inaccurate Warning" Overrides in the Intensive Care Unit.

    PubMed

    Rehr, Christine A; Wong, Adrian; Seger, Diane L; Bates, David W

    2018-04-01

     This article aims to understand provider behavior around the use of the override reason "Inaccurate warning," specifically whether it is an effective way of identifying unhelpful medication alerts.  We analyzed alert overrides that occurred in the intensive care units (ICUs) of a major academic medical center between June and November 2016, focused on the following high-significance alert types: dose, drug-allergy alerts, and drug-drug interactions (DDI). Override appropriateness was analyzed by two independent reviewers using predetermined criteria.  A total of 268 of 26,501 ICU overrides (1.0%) used the reason "Inaccurate warning," with 93 of these overrides associated with our included alert types. Sixty-one of these overrides (66%) were identified to be appropriate. Twenty-one of 30 (70%) dose alert overrides were appropriate. Forty of 48 drug-allergy alert overrides (83%) were appropriate, for reasons ranging from prior tolerance ( n  = 30) to inaccurate ingredient matches ( n  = 5). None of the 15 DDI overrides were appropriate.  The "Inaccurate warning" reason was selectively used by a small proportion of providers and overrides using this reason identified important opportunities to reduce excess alerts. Potential opportunities include improved evaluation of dosing mechanisms based on patient characteristics, inclusion of institutional dosing protocols to alert logic, and evaluation of a patient's prior tolerance to a medication that they have a documented allergy for. This resource is not yet routinely used for alert tailoring at our institution but may prove to be a valuable resource to evaluate available alerts. Schattauer GmbH Stuttgart.

  17. Runway Safety Monitor Algorithm for Runway Incursion Detection and Alerting

    NASA Technical Reports Server (NTRS)

    Green, David F., Jr.; Jones, Denise R. (Technical Monitor)

    2002-01-01

    The Runway Safety Monitor (RSM) is an algorithm for runway incursion detection and alerting that was developed in support of NASA's Runway Incursion Prevention System (RIPS) research conducted under the NASA Aviation Safety Program's Synthetic Vision System element. The RSM algorithm provides pilots with enhanced situational awareness and warnings of runway incursions in sufficient time to take evasive action and avoid accidents during landings, takeoffs, or taxiing on the runway. The RSM currently runs as a component of the NASA Integrated Display System, an experimental avionics software system for terminal area and surface operations. However, the RSM algorithm can be implemented as a separate program to run on any aircraft with traffic data link capability. The report documents the RSM software and describes in detail how RSM performs runway incursion detection and alerting functions for NASA RIPS. The report also describes the RIPS flight tests conducted at the Dallas-Ft Worth International Airport (DFW) during September and October of 2000, and the RSM performance results and lessons learned from those flight tests.

  18. Expression of thyroid hormone regulator genes in the yolk sac membrane of the developing chicken embryo

    PubMed Central

    TOO, Hanny Cho; SHIBATA, Mitsuhiro; YAYOTA, Masato; DARRAS, Veerle M.; IWASAWA, Atsushi

    2017-01-01

    Thyroid hormones (THs) are essential for the correct development of nearly every structure in the body from the very early stages of development, yet the embryonic thyroid gland is not functional at these stages. To clarify the roles of the egg yolk as a source of THs, the TH content in the yolk and the expression of TH regulator genes in the yolk sac membrane were evaluated throughout the 21-day incubation period of chicken embryos. The yolk TH content (22.3 ng triiodothyronine and 654.7 ng thyroxine per total yolk on day 4 of incubation) decreased almost linearly along with development. Real-time PCR revealed gene expression of transthyretin, a principal TH distributor in the chicken, and of a TH-inactivating iodothyronine deiodinase (DIO3), until the second week of incubation when the embryonic pituitary-thyroid axis is generally thought to start functioning. The TH-activating deiodinase (DIO2) and transmembrane transporter of thyroxine (SLCO1C1) genes were expressed in the last week of incubation, which coincided with a marked increase of circulating thyroxine and a reduction in the yolk sac weight. DIO1, which can remove iodine from inactive THs, was expressed throughout the incubation period. It is assumed that the chicken yolk sac inactivates THs contained abundantly in the yolk and supplies the hormones to the developing embryo in appropriate concentrations until the second week of incubation, while THs may be activated in the yolk sac membrane in the last week of incubation. Additionally, the yolk sac could serve as a source of iodine for the embryo. PMID:28652559

  19. Delivering Alert Messages to Members of a Work Force

    NASA Technical Reports Server (NTRS)

    Loftis, Julia; Nickens, Stephanie; Pell, Melissa; Pell, Vince

    2008-01-01

    Global Alert Resolution Network (GARNET) is a software system for delivering emergency alerts as well as less-urgent messages to members of the Goddard Space Flight Center work force via an intranet or the Internet, and can be adapted to similar use in other large organizations.

  20. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...

  1. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...

  2. 47 CFR 80.1113 - Transmission of a distress alert.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SERVICES STATIONS IN THE MARITIME SERVICES Global Maritime Distress and Safety System (GMDSS) Operating...-shore distress alerts are used to alert Rescue Coordination Centers via coast stations or coast earth... (from a ship earth station or a satellite EPIRB) and terrestrial services (from ship stations and EPIRBs...

  3. Total laparorobotic repair of abdominal aortic aneurysm with sac exclusion obliteration and aortobifemoral bypass.

    PubMed

    Wu, Timothy; Prema, Jateen; Zagaja, Gregory; Shalhav, Arieh; Bassiouny, Hisham S

    2009-01-01

    A 65-year-old man with coronary artery disease, hypertension, and peripheral vascular disease was found to have an asymptomatic abdominal aortic aneurysm (AAA) of 5.5 cm on surveillance for his peripheral vascular disease. Cardiac stress testing demonstrated no evidence of myocardial ischemia, and he opted to undergo open repair of his aneurysm. Laparorobotic repair of the infrarenal AAA using the da Vinci robotic system was performed with an aortobifemoral bypass. We describe a novel technique for AAA exclusion using a cerclage method, which greatly facilitates repair of infrarenal AAAs using laparorobotic techniques. Laparorobotic repair of infrarenal AAA can be greatly facilitated by AAA sac exclusion and obliteration without the need to ligate all lumbar arteries or to open the aneurysm. This virtually avoids blood loss from the sac and minimizes the possibility for open conversion as a result of poor visualization. Minimally invasive aortic intervention for aneurysmal disease using laparascopic methods has been reported in the literature. Problems associated with this technique include a prolonged learning curve and difficulty completing intracorporeal anastomoses. Robotic surgery provides an advantage over laparoscopic surgery in its ability to provide greater degrees of freedom in a relatively small field of view along with superior high-definition, three-dimensional visualization. To date, there have been no known reports of using robotic surgery in the United States as a sole method for repair of AAA. We report our technique of combining robotic surgery with a novel procedure for sac exclusion and obliteration to successfully repair AAA without the need for opening the aneurysm sac and endoaneurysmorrhaphy.

  4. Closing the Loop in ICU Decision Support: Physiologic Event Detection, Alerts, and Documentation

    PubMed Central

    Norris, Patrick R.; Dawant, Benoit M.

    2002-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users’ alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility.

  5. Closing the loop in ICU decision support: physiologic event detection, alerts, and documentation.

    PubMed Central

    Norris, P. R.; Dawant, B. M.

    2001-01-01

    Automated physiologic event detection and alerting is a challenging task in the ICU. Ideally care providers should be alerted only when events are clinically significant and there is opportunity for corrective action. However, the concepts of clinical significance and opportunity are difficult to define in automated systems, and effectiveness of alerting algorithms is difficult to measure. This paper describes recent efforts on the Simon project to capture information from ICU care providers about patient state and therapy in response to alerts, in order to assess the value of event definitions and progressively refine alerting algorithms. Event definitions for intracranial pressure and cerebral perfusion pressure were studied by implementing a reliable system to automatically deliver alerts to clinical users alphanumeric pagers, and to capture associated documentation about patient state and therapy when the alerts occurred. During a 6-month test period in the trauma ICU at Vanderbilt University Medical Center, 530 alerts were detected in 2280 hours of data spanning 14 patients. Clinical users electronically documented 81% of these alerts as they occurred. Retrospectively classifying documentation based on therapeutic actions taken, or reasons why actions were not taken, provided useful information about ways to potentially improve event definitions and enhance system utility. PMID:11825238

  6. Post-crisis analysis of an ineffective tsunami alert: the 2010 earthquake in Maule, Chile.

    PubMed

    Soulé, Bastien

    2014-04-01

    Considering its huge magnitude and its location in a densely populated area of Chile, the Maule seism of 27 February 2010 generated a low amount of victims. However, post-seismic tsunamis were particularly devastating on that day; surprisingly, no full alert was launched, not at the national, regional or local level. This earthquake and associated tsunamis are of interest in the context of natural hazards management as well as crisis management planning. Instead of focusing exclusively on the event itself, this article places emphasis on the process, systems and long-term approach that led the tsunami alert mechanism to be ineffectual. Notably, this perspective reveals interrelated forerunner signs of vulnerability. © 2014 The Author(s). Disasters © Overseas Development Institute, 2014.

  7. Factors influencing alert acceptance: a novel approach for predicting the success of clinical decision support

    PubMed Central

    Seidling, Hanna M; Phansalkar, Shobha; Seger, Diane L; Paterno, Marilyn D; Shaykevich, Shimon; Haefeli, Walter E

    2011-01-01

    Background Clinical decision support systems can prevent knowledge-based prescription errors and improve patient outcomes. The clinical effectiveness of these systems, however, is substantially limited by poor user acceptance of presented warnings. To enhance alert acceptance it may be useful to quantify the impact of potential modulators of acceptance. Methods We built a logistic regression model to predict alert acceptance of drug–drug interaction (DDI) alerts in three different settings. Ten variables from the clinical and human factors literature were evaluated as potential modulators of provider alert acceptance. ORs were calculated for the impact of knowledge quality, alert display, textual information, prioritization, setting, patient age, dose-dependent toxicity, alert frequency, alert level, and required acknowledgment on acceptance of the DDI alert. Results 50 788 DDI alerts were analyzed. Providers accepted only 1.4% of non-interruptive alerts. For interruptive alerts, user acceptance positively correlated with frequency of the alert (OR 1.30, 95% CI 1.23 to 1.38), quality of display (4.75, 3.87 to 5.84), and alert level (1.74, 1.63 to 1.86). Alert acceptance was higher in inpatients (2.63, 2.32 to 2.97) and for drugs with dose-dependent toxicity (1.13, 1.07 to 1.21). The textual information influenced the mode of reaction and providers were more likely to modify the prescription if the message contained detailed advice on how to manage the DDI. Conclusion We evaluated potential modulators of alert acceptance by assessing content and human factors issues, and quantified the impact of a number of specific factors which influence alert acceptance. This information may help improve clinical decision support systems design. PMID:21571746

  8. PubMedAlertMe - Standalone Windows-based PubMed SDI Software Application

    PubMed Central

    Ma’ayan, Avi

    2008-01-01

    PubMedAlertMe is a Windows-based software system for automatically receiving e-mail alert messages about recent publications listed on PubMed. The e-mail messages contain links to newly available abstracts listed on PubMed describing publications that were selectively returned from a specified list of queries. Links are also provided to directly export citations to EndNote, and links are provided to directly forward articles to colleagues. The program is standalone. Thus, it does not require a remote mail server or user registration. PubMedAlertMe is free software, and can be downloaded from: http://amp.pharm.mssm.edu/PubMedAlertMe/PubMedAlertMe_setup.zip PMID:18402930

  9. Feature Selection Using Information Gain for Improved Structural-Based Alert Correlation

    PubMed Central

    Siraj, Maheyzah Md; Zainal, Anazida; Elshoush, Huwaida Tagelsir; Elhaj, Fatin

    2016-01-01

    Grouping and clustering alerts for intrusion detection based on the similarity of features is referred to as structurally base alert correlation and can discover a list of attack steps. Previous researchers selected different features and data sources manually based on their knowledge and experience, which lead to the less accurate identification of attack steps and inconsistent performance of clustering accuracy. Furthermore, the existing alert correlation systems deal with a huge amount of data that contains null values, incomplete information, and irrelevant features causing the analysis of the alerts to be tedious, time-consuming and error-prone. Therefore, this paper focuses on selecting accurate and significant features of alerts that are appropriate to represent the attack steps, thus, enhancing the structural-based alert correlation model. A two-tier feature selection method is proposed to obtain the significant features. The first tier aims at ranking the subset of features based on high information gain entropy in decreasing order. The‏ second tier extends additional features with a better discriminative ability than the initially ranked features. Performance analysis results show the significance of the selected features in terms of the clustering accuracy using 2000 DARPA intrusion detection scenario-specific dataset. PMID:27893821

  10. Time to Detection with BacT/Alert FA Plus Compared to BacT/Alert FA Blood Culture Media.

    PubMed

    Nutman, A; Fisher Even-Tsur, S; Shapiro, G; Braun, T; Schwartz, D; Carmeli, Y

    2016-09-01

    Rapid identification of the causative pathogen in patients with bacteremia allows adjustment of antibiotic therapy and improves patient outcomes. We compared in vitro and real-life time to detection (TTD) of two blood culture media, BacT/Alert FA (FA) and BacT/Alert FA Plus (FA Plus), for the nine most common species of bacterial pathogens recovered from blood samples. Experimental data from simulated cultures was compared with microbiology records of TTD for both culture media with growth of the species of interest in clinical blood cultures. In the experimental conditions, median TTD was 3.8 hours (23.9 %) shorter using FA Plus media. The magnitude of reduction differed between species. Similarly, in real life data, FA Plus had shorter TTD than FA media; however, the difference between culture media was smaller, and median TTD was only 1 hour (8.5 %) less. We found shorter TTD with BacT/Alert FA Plus culture media, both experimentally and in real-life conditions and unrelated to antibiotic neutralization, highlighting the importance of appropriate blood culture media selection.

  11. Fine structures of the ejaculatory sac and sperm pump of the scorpionfly Panorpa liui Hua (Mecoptera: Panorpidae).

    PubMed

    Shen, Jian; Hua, Baozhen

    2013-08-01

    Male adults of Panorpidae possess a special sperm pump, through which the males transfer liquid sperm to the females. However, the structures of the sperm pump and the transfer mechanism have not been satisfactorily elucidated hitherto. In this paper the structures of the ejaculatory sac and sperm pump of the scorpionfly Panorpa liui Hua were investigated using light microscopy and scanning electron microscopy. The ejaculatory sac is located between the basal end of the paired vasa deferentia and the aedeagus, comprising a small anterior part and a large posterior part. The anterior part is simple and functions only as a channel for sperm transfer. The epithelial cells of the large posterior part likely have secretory functions. The sperm pump is formed by the posterior region of the ejaculatory sac and derivates of the genital field, which enclose the pumping chamber, a piston and the associated muscles. The orifice of the ejaculatory duct lies ventrad of the piston. The piston of the sperm pump is heavily sclerotized and controlled by two antagonistic muscle pairs. A pair of simple tubular accessory glands opens to the pumping chamber. Two well-developed sex pheromone glands are located on the ventral side of the ejaculatory sac, and are composed of two fan-shaped lamellae. The epithelium of the sex pheromone glands is single-layered, and forms densely filamentous processes. The ejaculation mechanism is briefly discussed based on the morphology of ejaculatory sac and sperm pump. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Evidence of the most stretchable egg sac silk stalk, of the European spider of the year Meta menardi.

    PubMed

    Lepore, Emiliano; Marchioro, Andrea; Isaia, Marco; Buehler, Markus J; Pugno, Nicola M

    2012-01-01

    Spider silks display generally strong mechanical properties, even if differences between species and within the same species can be observed. While many different types of silks have been tested, the mechanical properties of stalks of silk taken from the egg sac of the cave spider Meta menardi have not yet been analyzed. Meta menardi has recently been chosen as the "European spider of the year 2012", from the European Society of Arachnology. Here we report a study where silk stalks were collected directly from several caves in the north-west of Italy. Field emission scanning electron microscope (FESEM) images showed that stalks are made up of a large number of threads, each of them with diameter of 6.03 ± 0.58 µm. The stalks were strained at the constant rate of 2 mm/min, using a tensile testing machine. The observed maximum stress, strain and toughness modulus, defined as the area under the stress-strain curve, are 0.64 GPa, 751% and 130.7 MJ/m(3), respectively. To the best of our knowledge, such an observed huge elongation has never been reported for egg sac silk stalks and suggests a huge unrolling microscopic mechanism of the macroscopic stalk that, as a continuation of the protective egg sac, is expected to be composed by fibres very densely and randomly packed. The Weibull statistics was used to analyze the results from mechanical testing, and an average value of Weibull modulus (m) is deduced to be in the range of 1.5-1.8 with a Weibull scale parameter (σ(0)) in the range of 0.33-0.41 GPa, showing a high coefficient of correlation (R(2) = 0.97).

  13. Cytologically atypical anal sac adenocarcinoma in a dog.

    PubMed

    Sakai, Hiroki; Murakami, Mami; Mishima, Hiroyuki; Hoshino, Yuki; Mori, Takashi; Maruo, Kohji; Yanai, Tokuma

    2012-06-01

    A 10-year-old intact female Shetland Sheepdog with tenesmus had a subcutaneous mass at the left ventral aspect of the anus. On cytologic examination, 2 types of cells were observed. Most of the cells were oval to polygonal and had elliptical or elongate nuclei and a moderate amount of pale to basophilic cytoplasm. The remaining cells had round to oval nuclei and pale to basophilic cytoplasm. Cells of both types were loosely adhered to each other and were arranged in rosette-like structures. Both neoplastic cell types had fine homogenous chromatin and either a small indistinct nucleolus or no visible nucleolus. Mild anisokaryosis and anisocytosis were observed. Histologically, the mass consists of glandular structures formed by cuboidal cells admixed with bundles of spindle cells. Eosinophilic PAS- and Alcian blue-positive secretory material was found in the center of some glandular structures. Both neoplastic cell types had positive staining with paradoxical concanavalin A and expressed cytokeratin, but not vimentin, S-100, α-smooth muscle actin, or desmin. Based on location and histologic and immunohistochemical features, the final diagnosis was adenocarcinoma of the apocrine gland of the anal sac, which should be included as a cytologic differential diagnosis when spindle cells and typical epithelial cells are observed in masses in the region of the anal sac of dogs. © 2012 American Society for Veterinary Clinical Pathology.

  14. Sounding the Alert: Designing an Effective Voice for Earthquake Early Warning

    NASA Astrophysics Data System (ADS)

    Burkett, E. R.; Given, D. D.

    2015-12-01

    The USGS is working with partners to develop the ShakeAlert Earthquake Early Warning (EEW) system (http://pubs.usgs.gov/fs/2014/3083/) to protect life and property along the U.S. West Coast, where the highest national seismic hazard is concentrated. EEW sends an alert that shaking from an earthquake is on its way (in seconds to tens of seconds) to allow recipients or automated systems to take appropriate actions at their location to protect themselves and/or sensitive equipment. ShakeAlert is transitioning toward a production prototype phase in which test users might begin testing applications of the technology. While a subset of uses will be automated (e.g., opening fire house doors), other applications will alert individuals by radio or cellphone notifications and require behavioral decisions to protect themselves (e.g., "Drop, Cover, Hold On"). The project needs to select and move forward with a consistent alert sound to be widely and quickly recognized as an earthquake alert. In this study we combine EEW science and capabilities with an understanding of human behavior from the social and psychological sciences to provide insight toward the design of effective sounds to help best motivate proper action by alert recipients. We present a review of existing research and literature, compiled as considerations and recommendations for alert sound characteristics optimized for EEW. We do not yet address wording of an audible message about the earthquake (e.g., intensity and timing until arrival of shaking or possible actions), although it will be a future component to accompany the sound. We consider pitch(es), loudness, rhythm, tempo, duration, and harmony. Important behavioral responses to sound to take into account include that people respond to discordant sounds with anxiety, can be calmed by harmony and softness, and are innately alerted by loud and abrupt sounds, although levels high enough to be auditory stressors can negatively impact human judgment.

  15. Fecal sacs attract insects to the nest and provoke an activation of the immune system of nestlings.

    PubMed

    Ibáñez-Álamo, Juan Diego; Ruiz-Raya, Francisco; Rodríguez, Laura; Soler, Manuel

    2016-01-01

    Nest sanitation is a widespread but rarely studied behavior in birds. The most common form of nest sanitation behavior, the removal of nestling feces, has focused the discussion about which selective pressures determine this behavior. The parasitism hypothesis, which states that nestling fecal sacs attract parasites that negatively affect breeding birds, was proposed 40 years ago and is frequently cited as a demonstrated fact. But, to our knowledge, there is no previous experimental test of this hypothesis. We carried out three different experiments to investigate the parasitism hypothesis. First, we used commercial McPhail traps to test for the potential attraction effect of nestling feces alone on flying insects. We found that traps with fecal sacs attracted significantly more flies (Order Diptera), but not ectoparasites, than the two control situations. Second, we used artificial blackbird (Turdus merula) nests to investigate the combined attraction effect of feces and nest materials on arthropods (not only flying insects). Flies, again, were the only group of arthropods significantly attracted by fecal sacs. We did not detect an effect on ectoparasites. Third, we used active blackbird nests to investigate the potential effect of nestling feces in ecto- and endoparasite loads in real nestlings. The presence of fecal sacs near blackbird nestlings did not increase the number of louse flies or chewing lice, and unexpectedly reduced the number of nests infested with mites. The endoparasite prevalence was also not affected. In contrast, feces provoked an activation of the immune system as the H/L ratio of nestlings living near excrements was significantly higher than those kept under the two control treatments. Surprisingly, our findings do not support the parasitism hypothesis, which suggests that parasites are not the main reason for fecal sac removal. In contrast, the attraction of flies to nestling feces, the elevation of the immune response of chicks, and the

  16. 76 FR 81904 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-29

    ... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... Special Fraud Alerts. DATES: To assure consideration, public comments must be delivered to the address... and Special Fraud Alerts. Please assist us by referencing the file code OIG-120-N. Inspection of...

  17. Alerting or Somnogenic Light: Pick Your Color.

    PubMed

    Bourgin, Patrice; Hubbard, Jeffrey

    2016-08-01

    In mammals, light exerts pervasive effects on physiology and behavior in two ways: indirectly through clock synchronization and the phase adjustment of circadian rhythms, and directly through the promotion of alertness and sleep, respectively, in diurnal and nocturnal species. A recent report by Pilorz and colleagues describes an even more complex role for the acute effects of light. In mice, blue light acutely causes behavioral arousal, whereas green wavelengths promote sleep. These opposing effects are mediated by melanopsin-based phototransduction through different neural pathways. These findings reconcile nocturnal and diurnal species through a common alerting response to blue light. One can hypothesize that the opposite responses to natural polychromatic light in night- or day-active animals may reflect higher sensitivity of nocturnal species to green, and diurnals to blue wavelengths, resulting in hypnogenic and alerting effects, respectively. Additional questions remain to be clarified. How do different light wavelengths affect other behaviors such as mood and cognition? How do those results apply to humans? How does light pose either a risk or benefit, depending on whether one needs to be asleep or alert? Indeed, in addition to timing, luminance levels, and light exposure duration, these findings stress the need to understand how best to adapt the color spectrum of light to our needs and to take this into account for the design of daily lighting concepts-a key challenge for today's society, especially with the emergence of LED light technology.

  18. Alerts of forest disturbance from MODIS imagery

    NASA Astrophysics Data System (ADS)

    Hammer, Dan; Kraft, Robin; Wheeler, David

    2014-12-01

    This paper reports the methodology and computational strategy for a forest cover disturbance alerting system. Analytical techniques from time series econometrics are applied to imagery from the Moderate Resolution Imaging Spectroradiometer (MODIS) sensor to detect temporal instability in vegetation indices. The characteristics from each MODIS pixel's spectral history are extracted and compared against historical data on forest cover loss to develop a geographically localized classification rule that can be applied across the humid tropical biome. The final output is a probability of forest disturbance for each 500 m pixel that is updated every 16 days. The primary objective is to provide high-confidence alerts of forest disturbance, while minimizing false positives. We find that the alerts serve this purpose exceedingly well in Pará, Brazil, with high probability alerts garnering a user accuracy of 98 percent over the training period and 93 percent after the training period (2000-2005) when compared against the PRODES deforestation data set, which is used to assess spatial accuracy. Implemented in Clojure and Java on the Hadoop distributed data processing platform, the algorithm is a fast, automated, and open source system for detecting forest disturbance. It is intended to be used in conjunction with higher-resolution imagery and data products that cannot be updated as quickly as MODIS-based data products. By highlighting hotspots of change, the algorithm and associated output can focus high-resolution data acquisition and aid in efforts to enforce local forest conservation efforts.

  19. Advantages and Disadvantages of Educational Email Alerts for Family Physicians: Viewpoint

    PubMed Central

    Badran, Hani; Grad, Roland

    2015-01-01

    Background Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. Objective The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians’ knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants’ suggestions to improve email alert services for CME. Methods We conducted a qualitative descriptive study using the “Knowledge, Attitude, Behavior” model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. Results All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. Conclusions The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts. PMID:25803184

  20. Advantages and disadvantages of educational email alerts for family physicians: viewpoint.

    PubMed

    Badran, Hani; Pluye, Pierre; Grad, Roland

    2015-02-27

    Electronic knowledge resources constitute an important channel for accredited Continuing Medical Education (CME) activities. However, email usage for educational purposes is controversial. On the one hand, family physicians become aware of new information, confirm what they already know, and obtain reassurance by reading educational email alerts. Email alerts can also encourage physicians to search Web-based resources. On the other hand, technical difficulties and privacy issues are common obstacles. The purpose of this discussion paper, informed by a literature review and a small qualitative study, was to understand family physicians' knowledge, attitudes, and behavior in regard to email in general and educational emails in particular, and to explore the advantages and disadvantages of educational email alerts. In addition, we documented participants' suggestions to improve email alert services for CME. We conducted a qualitative descriptive study using the "Knowledge, Attitude, Behavior" model. We conducted semi-structured face-to-face interviews with 15 family physicians. We analyzed the collected data using inductive-deductive thematic qualitative data analysis. All 15 participants scanned and prioritized their email, and 13 of them checked their email daily. Participants mentioned (1) advantages of educational email alerts such as saving time, convenience and valid information, and (2) disadvantages such as an overwhelming number of emails and irrelevance. They offered suggestions to improve educational email. The advantages of email alerts seem to compensate for their disadvantages. Suggestions proposed by family physicians can help to improve educational email alerts.

  1. A Novel Technique to Detect Code for SAC-OCDMA System

    NASA Astrophysics Data System (ADS)

    Bharti, Manisha; Kumar, Manoj; Sharma, Ajay K.

    2018-04-01

    The main task of optical code division multiple access (OCDMA) system is the detection of code used by a user in presence of multiple access interference (MAI). In this paper, new method of detection known as XOR subtraction detection for spectral amplitude coding OCDMA (SAC-OCDMA) based on double weight codes has been proposed and presented. As MAI is the main source of performance deterioration in OCDMA system, therefore, SAC technique is used in this paper to eliminate the effect of MAI up to a large extent. A comparative analysis is then made between the proposed scheme and other conventional detection schemes used like complimentary subtraction detection, AND subtraction detection and NAND subtraction detection. The system performance is characterized by Q-factor, BER and received optical power (ROP) with respect to input laser power and fiber length. The theoretical and simulation investigations reveal that the proposed detection technique provides better quality factor, security and received power in comparison to other conventional techniques. The wide opening of eye in case of proposed technique also proves its robustness.

  2. Identification of Patients Expected to Benefit from Electronic Alerts for Acute Kidney Injury.

    PubMed

    Biswas, Aditya; Parikh, Chirag R; Feldman, Harold I; Garg, Amit X; Latham, Stephen; Lin, Haiqun; Palevsky, Paul M; Ugwuowo, Ugochukwu; Wilson, F Perry

    2018-06-07

    Electronic alerts for heterogenous conditions such as AKI may not provide benefit for all eligible patients and can lead to alert fatigue, suggesting that personalized alert targeting may be useful. Uplift-based alert targeting may be superior to purely prognostic-targeting of interventions because uplift models assess marginal treatment effect rather than likelihood of outcome. This is a secondary analysis of a clinical trial of 2278 adult patients with AKI randomized to an automated, electronic alert system versus usual care. We used three uplift algorithms and one purely prognostic algorithm, trained in 70% of the data, and evaluated the effect of targeting alerts to patients with higher scores in the held-out 30% of the data. The performance of the targeting strategy was assessed as the interaction between the model prediction of likelihood to benefit from alerts and randomization status. The outcome of interest was maximum relative change in creatinine from the time of randomization to 3 days after randomization. The three uplift score algorithms all gave rise to a significant interaction term, suggesting that a strategy of targeting individuals with higher uplift scores would lead to a beneficial effect of AKI alerting, in contrast to the null effect seen in the overall study. The prognostic model did not successfully stratify patients with regards to benefit of the intervention. Among individuals in the high uplift group, alerting was associated with a median reduction in change in creatinine of -5.3% ( P =0.03). In the low uplift group, alerting was associated with a median increase in change in creatinine of +5.3% ( P =0.005). Older individuals, women, and those with a lower randomization creatinine were more likely to receive high uplift scores, suggesting that alerts may benefit those with more slowly developing AKI. Uplift modeling, which accounts for treatment effect, can successfully target electronic alerts for AKI to those most likely to benefit

  3. Expression of PDGFR-β and Kit in canine anal sac apocrine gland adenocarcinoma using tissue immunohistochemistry.

    PubMed

    Brown, R J; Newman, S J; Durtschi, D C; Leblanc, A K

    2012-03-01

    Canine anal sac apocrine gland adenocarcinoma (ASAGAC) is an uncommon but highly invasive and metastatic malignancy. Toceranib phosphate (Palladia) is a receptor tyrosine kinase (RTK) inhibitor that targets several members of the split kinase RTK family. These membrane receptors are important for cell cycling, apoptosis and angiogenesis, all of which can contribute to carcinogenesis. The objective of this study was to evaluate archived, paraffin-embedded canine ASAGAC and normal canine anal sacs for immunohistochemical detection of Kit and platelet-derived growth factor receptor beta (PDGFR-β). Two of 77 neoplasms (2.6%) expressed Kit. Fifteen of the neoplasms (19.5%) were positive for PDGFR-β expression. None of the normal canine anal sac epithelium expressed Kit or PDGFR-β. Because of these results, further investigation should be considered to determine the role of RTKs in the clinical course and treatment of canine ASAGAC. © 2011 Blackwell Publishing Ltd.

  4. 75 FR 4760 - Review of the Emergency Alert System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-29

    ...; State, Local or Tribal Governments; Non-profit entities. Number of Respondents: 3,569,028. Estimated... hours. Total Annual Cost: $3,086,044. Privacy Impact Assessment: No impact(s). Nature and Extent of... retransmitted the alert; and (3) if they were not able to receive and/ or transmit the alert, their `best effort...

  5. The DOPA decarboxylase (DDC) gene is associated with alerting attention.

    PubMed

    Zhu, Bi; Chen, Chuansheng; Moyzis, Robert K; Dong, Qi; Chen, Chunhui; He, Qinghua; Li, Jin; Li, Jun; Lei, Xuemei; Lin, Chongde

    2013-06-03

    DOPA decarboxylase (DDC) is involved in the synthesis of dopamine, norepinephrine and serotonin. It has been suggested that genes involved in the dopamine, norepinephrine, and cholinergic systems play an essential role in the efficiency of human attention networks. Attention refers to the cognitive process of obtaining and maintaining the alert state, orienting to sensory events, and regulating the conflicts of thoughts and behavior. The present study tested seven single nucleotide polymorphisms (SNPs) within the DDC gene for association with attention, which was assessed by the Attention Network Test to detect three networks of attention, including alerting, orienting, and executive attention, in a healthy Han Chinese sample (N=451). Association analysis for individual SNPs indicated that four of the seven SNPs (rs3887825, rs7786398, rs10499695, and rs6969081) were significantly associated with alerting attention. Haplotype-based association analysis revealed that alerting was associated with the haplotype G-A-T for SNPs rs7786398-rs10499695-rs6969081. These associations remained significant after correcting for multiple testing by max(T) permutation. No association was found for orienting and executive attention. This study provides the first evidence for the involvement of the DDC gene in alerting attention. A better understanding of the genetic basis of distinct attention networks would allow us to develop more effective diagnosis, treatment, and prevention of deficient or underdeveloped alerting attention as well as its related prevalent neuropsychiatric disorders. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes

    PubMed Central

    Los, Evan A.; Ramsey, Katrina L.; Guttmann-Bauman, Ines; Ahmann, Andrew J.

    2016-01-01

    Background: We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Methods: Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Results: Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog’s ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). Conclusions: This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin. PMID:27573791

  7. Reliability of Trained Dogs to Alert to Hypoglycemia in Patients With Type 1 Diabetes.

    PubMed

    Los, Evan A; Ramsey, Katrina L; Guttmann-Bauman, Ines; Ahmann, Andrew J

    2017-05-01

    We examined the reliability of trained dogs to alert to hypoglycemia in individuals with type 1 diabetes. Patients with type 1 diabetes who currently used diabetes alert dogs participated in this exploratory study. Subjects reported satisfaction, perceived dog glucose sensing ability and reasons for obtaining a trained dog. Reliability of dog alerts was assessed using capillary blood glucose (CBG) and blinded continuous glucose monitoring (CGM) as comparators in 8 subjects (age 4-48). Hypoglycemia was defined as CBG or CGM <70 mg/dL. Dog users were very satisfied (8.9/10 on a Likert-type scale) and largely confident (7.9/10) in their dog's ability to detect hypoglycemia. Detection of hypoglycemia was the primary reason for obtaining a trained dog. During hypoglycemia, spontaneous dog alerts occurred at a rate 3.2 (2.0-5.2, 95% CI) times higher than during euglycemia (70-179 mg/dL). Dogs provided timely alerts in 36% (sensitivity) of all hypoglycemia events (n = 45). Due to inappropriate alerts, the PPV of a dog alert for hypoglycemia was 12%. When there was concurrence of a hypoglycemic event between the dog alert and CGM (n = 30), CGM would have alerted prior to the dog in 73% of events (median 22-minute difference). This is the first study evaluating reliability of trained dogs to alert to hypoglycemia under real-life conditions. Trained dogs often alert a human companion to otherwise unknown hypoglycemia; however due to high false-positive rate, a dog alert alone is unlikely to be helpful in differentiating hypo-/hyper-/euglycemia. CGM often detects hypoglycemia before a trained dog by a clinically significant margin.

  8. Double sac sign and intradecidual sign in early pregnancy: interobserver reliability and frequency of occurrence.

    PubMed

    Doubilet, Peter M; Benson, Carol B

    2013-07-01

    To assess the interobserver agreement, frequency of occurrence, and prognostic importance of the double sac sign (DSS), intradecidual sign (IDS), and other sonographic findings in early intrauterine pregnancies. We retrospectively identified all sonograms obtained between January 1, 2006, and December 31, 2011, in which: (1) the scan demonstrated an intrauterine fluid collection without a yolk sac or embryo; (2) a follow-up scan confirmed an intrauterine pregnancy; and (3) the first-trimester outcome was known. Each coinvestigator characterized the 199 study sonograms as demonstrating or not demonstrating a DSS or an IDS, based on judgment about whether the scan met published criteria defining these signs. Interobserver agreement was poor for the DSS (κ= 0.24) and IDS (κ= 0.23). Scans frequently demonstrated neither sign: 150 cases (75.4%) if we considered a sign to be present when both investigators graded it as present and 69 cases (34.7%) using the looser criterion that either graded it as present. The presence of a DSS or an IDS was unrelated to the β-human chorionic gonadotropin (β-hCG) value (P > .05, t test, all comparisons). An inner echogenic ring was present in 158 cases (79.4%), and the decidua was brighter peripherally than centrally in 102 (51.3%). The first-trimester outcome was unrelated to the presence of a DSS or an IDS, presence of an inner echogenic ring, or decidual appearance (P > .05, χ(2), all comparisons). The sonographic appearance of early gestational sacs, before visualization of a yolk sac or embryo, is highly variable. The DSS and IDS are often absent; there is poor interobserver agreement regarding these signs; and the prognosis is unrelated to their presence or absence. A round or oval intrauterine fluid collection in a woman with positive β-hCG should be treated as a gestational sac until proven otherwise, regardless of whether it demonstrates a DSS or an IDS.

  9. The Montsec Observatory and the Gaia science alerts

    NASA Astrophysics Data System (ADS)

    Carrasco, J. M.; Burgaz, U.; Vilardell, F.; Jordi, C.

    2017-03-01

    The continuous and reiterative scan of the whole sky performed by Gaia ESA's mission during its (at least) 5 years of mission allows to detect transient events (e.g., supernovae, microlensing events, cataclysmic variables, etc) almost in real time among the daily millions of observations. The pipeline in charge to discover these alerts does a quick look analysis of the daily data stream, identify those sources increasing their brightness with respect to previous Gaia observations and also analyse their spectrophotometry to decide if those sources are good candidates to be published as a Gaia Photometric Science Alerts. These events are publicly announced for follow-up observations (both photometric and spectroscopic are needed). Observatories around the world confirm, classify and study them in detail. Observations are put in common and analysed together in a common interface in order to get a single analysis as detailed and precise as possible. Our team in Barcelona contributes to this Gaia science alerts follow-up programme with the 0.8 m robotic telescope Joan Oró (TJO), at the Montsec Observatory (OAdM), located at Sant Esteve de la Sarga (Lleida, Spain) performing photometric observations to derive the lightcurves of the most interesting alerts accessible from the observatory. Until now we have contributed with about 4500 images in multicolour Johnson-Cousins passbands obtained with TJO for a total of 38 Gaia science alerts, becoming the third most contributing observatory in the programme. Here we summarise the procedure to select new targets to be observed by TJO, submit follow-up observations and we explain the analysis we did for some interesting obtained lightcurves.

  10. Reaching out to clinicians: implementation of a computerized alert system.

    PubMed

    Degnan, Dan; Merryfield, Dave; Hultgren, Steve

    2004-01-01

    Several published articles have identified that providing automated, computer-generated clinical alerts about potentially critical clinical situations should result in better quality of care. In 1999, the pharmacy department at a community hospital network implemented and refined a commercially available, computerized clinical alert system. This case report discusses the implementation process, gives examples of how the system is used, and describes results following implementation. The use of the clinical alert system in this hospital network resulted in improved patient safety as well as in greater efficiency and decreased costs.

  11. Differential gene expression profiles in the venom gland/sac of Eumenes pomiformis (Hymenoptera: Eumenidae).

    PubMed

    Baek, Ji Hyeong; Lee, Si Hyeock

    2010-06-01

    To search for novel transcripts encoding biologically active venom components, a subtractive cDNA library specific to the venom gland and sac (gland/sac) of a solitary hunting wasp species, Eumenes pomiformis Fabricius (1781), was constructed by suppression subtractive hybridization. A total of 541 expressed sequence tags (ESTs) were clustered and assembled into 102 contigs (31 multiple sequences and 71 singletons). In total, 37 cDNAs were found in the library via BLASTx searching and manual annotation. Eight contigs (337 ESTs) encoding short venom peptides (10 to 16 amino acids) occupied 62% of the library. The deduced amino acid sequence (78 amino acids) of a novel venom peptide transcript shared sequence similarity with trypsin inhibitors and dendrotoxin-like venom peptides known to be K(+) channel blockers, implying that this novel peptide may play a role in the paralysis of prey. In addition to phospholipase A2 and hyaluronidase, which are known to be the main components of wasp venoms, several transcripts encoding enzymes, including three metallopeptidases and a decarboxylase likely involved in the processing and activation of venomous proteins, peptides, amines, and neurotransmitters, were also isolated from the library. The presence of a transcript encoding a putative insulin/insulin-like peptide binding protein suggests that solitary hunting wasps use their venom to control their prey, leading to larval growth cessation. The abundance of these venom components in the venom gland/sac and in the alimentary canal was confirmed by quantitative real-time PCR. Discovery of venom gland/sac-specific transcripts should promote further studies on biologically active components in the venom of solitary hunting wasps. Copyright 2010 Elsevier Ltd. All rights reserved.

  12. SAC-CI methodology applied to molecular spectroscopy and photo-biology

    NASA Astrophysics Data System (ADS)

    Hasegawa, J.; Miyahara, T.; Nakashima, H.; Nakatsuji, H.

    2012-06-01

    The SAC-CI method was applied to the spectroscopy of radical cations and anions of various organic molecules. It was also applied to photo-biology, in particular, to elucidate the bio-molecular color-tuning mechanism of human visions and to the circular dichroism spectroscopy that is used to understand the helical structures of DNA and RNA.

  13. Promoting Safety in Hypnosis: A Clinical Instrument for the Assessment of Alertness.

    PubMed

    Howard, Hedy A

    2017-04-01

    Hypnosis has long demonstrated its power to facilitate various approaches to psychotherapy. Like other potent modalities, hypnosis may produce unwanted effects. Although its negative sequelae are usually mild and transient, more serious complications may occur. Recently, attention has been drawn to the powerful role of failures of dehypnosis or alerting/realerting in producing unwanted effects. Traditionally, alerting has been viewed as a relatively uncomplicated process that requires little more than the simple suggestion that the subject will return or awaken from trance, and exiting from trance has generally been considered the cessation of the phenomena suggested during induction and thereafter. Newer findings challenge these assumptions and suggest that restoring the subject to a prehypnotic baseline level of alertness is of equal or greater importance. Here, I describe the Howard Alertness Scale (HAS), with which subjects can be made aware of their baseline levels of alertness to help them understand the unique ways that their trance states differ from their normal alert states, and assess and measure their subjective perception of alertness before and after hypnosis. Furthermore, regular use of the HAS holds potential to enhance both the therapeutic alliance and the patient's sense of safety and mastery. The development and use of the HAS is discussed along with three vignettes illustrating its clinical application.

  14. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  15. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  16. 47 CFR 80.1117 - Procedure for receipt and acknowledgement of distress alerts.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... radiotelephony of receipt of a distress alert from a ship station or a ship earth station must be given in the... telegraphy of receipt of a distress alert from a ship earth station must be given by the coast earth station... distress alerts. 80.1117 Section 80.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED...

  17. 78 FR 78807 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-27

    ... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... revised safe harbors and Special Fraud Alerts. Please assist us by referencing the file code OIG-122-N...

  18. 77 FR 76434 - Solicitation of New Safe Harbors and Special Fraud Alerts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-28

    ... of New Safe Harbors and Special Fraud Alerts AGENCY: Office of Inspector General (OIG), HHS. ACTION... statute (section 1128B(b) of the Social Security Act), as well as developing new OIG Special Fraud Alerts... revised safe harbors and Special Fraud Alerts. Please assist us by referencing the file code OIG-121-N...

  19. Automated inhaled nitric oxide alerts for adult extracorporeal membrane oxygenation patient identification.

    PubMed

    Belenkiy, Slava M; Batchinsky, Andriy I; Park, Timothy S; Luellen, David E; Serio-Melvin, Maria L; Cancio, Leopoldo C; Pamplin, Jeremy C; Chung, Kevin K; Salinas, Josè; Cannon, Jeremy W

    2014-09-01

    Recently, automated alerts have been used to identify patients with respiratory failure based on set criteria, which can be gleaned from the electronic medical record (EMR). Such an approach may also be useful for identifying patients with severe adult respiratory distress syndrome (ARDS) who may benefit from extracorporeal membrane oxygenation (ECMO). Inhaled nitric oxide (iNO) is a common rescue therapy for severe ARDS which can be easily tracked in the EMR, and some patients started on iNO may have indications for initiating ECMO. This case series summarizes our experience with using automated electronic alerts for ECMO team activation focused particularly on an alert triggered by the initiation of iNO. After a brief trial evaluation, our Smart Alert system generated an automated page and e-mail alert to ECMO team members whenever a nonzero value for iNO appeared in the respiratory care section of our EMR. If iNO was initiated for severe respiratory failure, a detailed evaluation by the ECMO team determined if ECMO was indicated. For those patients managed with ECMO, we tabulated baseline characteristics, indication for ECMO, and outcomes. From September 2012 to July 2013, 45 iNO alerts were generated on 42 unique patients. Six patients (14%) met criteria for ECMO. Of these, four were identified exclusively by the iNO alert. At the time of the alert, the median PaO₂-to-FIO₂ ratio was 64 mm Hg (range, 55-107 mm Hg), the median age-adjusted oxygenation index was 73 (range, 51-96), and the median Murray score was 3.4 (range, 3-3.75), indicating severe respiratory failure. Median time from iNO alert to ECMO initiation was 81 hours (range, -2-292 hours). Survival to hospital discharge was 83% in those managed with ECMO. Automated alerts may be useful for identifying patients with severe ARDS who may be ECMO candidates. Diagnostic test, level V.

  20. Wireless alerting system using vibration for vehicles dashboard

    NASA Astrophysics Data System (ADS)

    Raj, Sweta; Rai, Shweta; Magaramagara, Wilbert; Sivacoumar, R.

    2017-11-01

    This paper aims at improving the engine life of any vehicle through a continuous measurement and monitoring of vital engine operational parameters and providing an effective alerting to drivers for any abnormality. Vehicles currently are using audio and visible alerting signals through alarms and light as a warning to the driver but these are not effective in noisy environments and during daylight. Through the use of the sense of feeling a driver can be alerted effectively. The need to no other vehicle parameter needs to be aided through the mobile display (phone).Thus a system is designed and implements to measure engine temperature, RPM, Oil level and Coolant level using appropriate sensors and a wireless communication (Bluetooth) is established to actuate a portable vibration control device and to read the different vehicle sensor readings through an android application for display and diagnosis.

  1. [Clear cell carcinoma of the ovary simulating a yolk sac tumor].

    PubMed

    Bahri, Ibticem; Boudawara, Tahya; Khabir, Abdelmajid; Beyrouti, Mohamed Issam; Frikha, Mounir; Jlidi, Rachid

    2003-04-01

    Clear cell carcinoma (CCC) of the ovary is uncommon. In young patients, this tumor may simulate a yolk sac tumor. In this case, the morphologic distinction between these tumors is often difficult but the immunohistochemical staining for CA125 and alpha foeto protein (AFP) and the response to chemotherapy are particularly helpful to resolve this problem of differential diagnosis. We report a case of a 17 year old patient who was operated for a tumor of the right ovary. The diagnosis of a yolk sac tumor was first suggested. However, because of the non response to chemotherapy, a second laparotomy was performed; the definitive pathologic examination concluded to the diagnosis of a CCC of the ovary. The young age and the immunohistochemical staining for AFP are unusual and misleading features for a CCC. Our objective about this particular case is to discuss the anatomoclinical aspects of the CCC of the ovary and to prove the role of immunohistochemistry in the differential diagnosis.

  2. Dynamic malware containment under an epidemic model with alert

    NASA Astrophysics Data System (ADS)

    Zhang, Tianrui; Yang, Lu-Xing; Yang, Xiaofan; Wu, Yingbo; Tang, Yuan Yan

    2017-03-01

    Alerting at the early stage of malware invasion turns out to be an important complement to malware detection and elimination. This paper addresses the issue of how to dynamically contain the prevalence of malware at a lower cost, provided alerting is feasible. A controlled epidemic model with alert is established, and an optimal control problem based on the epidemic model is formulated. The optimality system for the optimal control problem is derived. The structure of an optimal control for the proposed optimal control problem is characterized under some conditions. Numerical examples show that the cost-efficiency of an optimal control strategy can be enhanced by adjusting the upper and lower bounds on admissible controls.

  3. Development of an "Alert Framework" Based on the Practices in the Medical Front.

    PubMed

    Sakata, Takuya; Araki, Kenji; Yamazaki, Tomoyoshi; Kawano, Koichi; Maeda, Minoru; Kushima, Muneo; Araki, Sanae

    2018-05-09

    At the University of Miyazaki Hospital (UMH), we have accumulated and semantically structured a vast amount of medical information since the activation of the electronic health record system approximately 10 years ago. With this medical information, we have decided to develop an alert system for aiding in medical treatment. The purpose of this investigation is to not only to integrate an alert framework into the electronic heath record system, but also to formulate a modeling method of this knowledge. A trial alert framework was developed for the staff in various occupational categories at the UMH. Based on findings of subsequent interviews, a more detailed and upgraded alert framework was constructed, resulting in the final model. Based on our current findings, an alert framework was developed with four major items. Based on the analysis of the medical practices from the trial model, it has been concluded that there are four major risk patterns that trigger the alert. Furthermore, the current alert framework contains detailed definitions which are easily substituted into the database, leading to easy implementation of the electronic health records.

  4. Strategies for Managing Smart Pump Alarm and Alert Fatigue: A Narrative Review.

    PubMed

    Shah, Parth K; Irizarry, Jamie; O'Neill, Sean

    2018-06-08

    Although smart infusion pumps are intended to prevent medication errors by alerting users about doses that exceed set thresholds, a large number of clinically insignificant alarms and alerts create the potential for alert and alarm fatigue. We searched the PubMed, Scopus, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) databases for peer-reviewed literature (January 1, 2004-August 31, 2017) on managing smart pump alerts, alarms, and related fatigue. Twenty-nine articles that met the inclusion criteria were reviewed and organized into themes. Smart pumps give users two types of signals: alarms that indicate mechanical issues such as occlusion, air in the line, or low battery; and clinical alerts that indicate that a programmed dose exceeds a predefined safety limit. Mechanical alarms occur with greater frequency than clinical alerts, but alarms and alerts vary widely by pump model, patient population, time of day, month, and type of drug. Several causes of clinically insignificant alerts and alarms may be actionable, and strategies proposed in the literature include development of a multidisciplinary team to oversee the quality improvement effort with involvement of end users, standardization of medication administration practices, widening of drug limit library thresholds when clinically appropriate, maintaining up-to-date drug limit libraries, and interoperability. Whereas many strategies have been proposed, and case studies have been reported, none have been rigorously evaluated. In addition, more research is needed related to managing occlusion and air-in-line alarms, especially for complicated infusions. Future work should focus on the evaluation of specific and replicable alert and alarm reduction strategies with a greater emphasis on quantitative metrics. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  5. Developing an Early-Alert System to Promote Student Visits to Tutor Center

    ERIC Educational Resources Information Center

    Cai, Qijie; Lewis, Carrie L.; Higdon, Jude

    2015-01-01

    An early-alert system (MavCLASS) was developed and piloted in a large gateway math class with 611 freshman students to identify academically at-risk students and provide alert messages. It was found that there was significant association between the alert messages students received and their visits to the university's tutor center. Further, the…

  6. Treatment with thiamine hydrochloride and astaxanthine for the prevention of yolk-sac mortality in Baltic salmon fry (M74 syndrome).

    PubMed

    Koski, P; Pakarinen, M; Nakari, T; Soivio, A; Hartikainen, K

    1999-09-14

    Two practical methods are reported for treating feral Baltic salmon with thiamine hydrochloride against M74 syndrome (abnormally high yolk-sac fry mortality of the Baltic salmon). Both bathing of the yolk-sac fry in thiamine hydrochloride (1000 mg l-1, 1 h) and a single intraperitoneal injection given to the female brood fish (100 mg kg-1 fish) during the summer 3 mo before stripping were shown to elevate the whole body total thiamine concentration in the fry. Both treatments were also shown to be effective in preventing mortality due to M74 syndrome. The effect of bathing the yolk-sac fry was shown to be dose-dependent. The results support the view that there is a causal relationship between the thiamine status of the yolk-sac fry and M74 mortality. An intraperitoneal injection of astaxanthine suspension administered to the female brood fish (11 mg kg-1 fish) in the summer 3 mo before stripping elevated the astaxanthine concentration in the eggs but did not affect mortality due to M74 syndrome. An interaction between astaxanthine and thiamine may occur in the developing embryo or yolk-sac fry, however. No association could be demonstrated between the various thiamine hydrochloride treatment practices and hepatic cytochrome P450 dependent 7-ethoxyresorufin-O-deethylase (EROD) activity in the yolk-sac fry. An injection of thiamine hydrochloride into the peritoneal cavity of wild Baltic salmon females could be used to raise thiamine concentrations in their offspring in the rivers. The effect on smolt production in Finnish Baltic salmon rivers needs to be investigated further, however.

  7. Generalized Philosophy of Alerting with Applications for Parallel Approach Collision Prevention

    NASA Technical Reports Server (NTRS)

    Winder, Lee F.; Kuchar, James K.

    2000-01-01

    The goal of the research was to develop formal guidelines for the design of hazard avoidance systems. An alerting system is automation designed to reduce the likelihood of undesirable outcomes that are due to rare failures in a human-controlled system. It accomplishes this by monitoring the system, and issuing warning messages to the human operators when thought necessary to head off a problem. On examination of existing and recently proposed logics for alerting it appears that few commonly accepted principles guide the design process. Different logics intended to address the same hazards may take disparate forms and emphasize different aspects of performance, because each reflects the intuitive priorities of a different designer. Because performance must be satisfactory to all users of an alerting system (implying a universal meaning of acceptable performance) and not just one designer, a proposed logic often undergoes significant piecemeal modification before gamma general acceptance. This report is an initial attempt to clarify the common performance goals by which an alerting system is ultimately judged. A better understanding of these goals will hopefully allow designers to reach the final logic in a quicker, more direct and repeatable manner. As a case study, this report compares three alerting logics for collision prevention during independent approaches to parallel runways, and outlines a fourth alternative incorporating elements of the first three, but satisfying stated requirements. Three existing logics for parallel approach alerting are described. Each follows from different intuitive principles. The logics are presented as examples of three "philosophies" of alerting system design.

  8. Bar Code Medication Administration Technology: Characterization of High-Alert Medication Triggers and Clinician Workarounds.

    PubMed

    Miller, Daniel F; Fortier, Christopher R; Garrison, Kelli L

    2011-02-01

    Bar code medication administration (BCMA) technology is gaining acceptance for its ability to prevent medication administration errors. However, studies suggest that improper use of BCMA technology can yield unsatisfactory error prevention and introduction of new potential medication errors. To evaluate the incidence of high-alert medication BCMA triggers and alert types and discuss the type of nursing and pharmacy workarounds occurring with the use of BCMA technology and the electronic medication administration record (eMAR). Medication scanning and override reports from January 1, 2008, through November 30, 2008, for all adult medical/surgical units were retrospectively evaluated for high-alert medication system triggers, alert types, and override reason documentation. An observational study of nursing workarounds on an adult medicine step-down unit was performed and an analysis of potential pharmacy workarounds affecting BCMA and the eMAR was also conducted. Seventeen percent of scanned medications triggered an error alert of which 55% were for high-alert medications. Insulin aspart, NPH insulin, hydromorphone, potassium chloride, and morphine were the top 5 high-alert medications that generated alert messages. Clinician override reasons for alerts were documented in only 23% of administrations. Observational studies assessing for nursing workarounds revealed a median of 3 clinician workarounds per administration. Specific nursing workarounds included a failure to scan medications/patient armband and scanning the bar code once the dosage has been removed from the unit-dose packaging. Analysis of pharmacy order entry process workarounds revealed the potential for missed doses, duplicate doses, and doses being scheduled at the wrong time. BCMA has the potential to prevent high-alert medication errors by alerting clinicians through alert messages. Nursing and pharmacy workarounds can limit the recognition of optimal safety outcomes and therefore workflow processes

  9. 76 FR 62321 - Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-07

    ... Communication & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) Units AGENCY... certain Aviation Communication & Surveillance Systems (ACSS) traffic alert and collision avoidance system...) traffic alert and collision avoidance system (TCAS) units with part numbers identified in ACSS Technical...

  10. Metastatic anal sac adenocarcinoma in a dog presenting for acute paralysis.

    PubMed

    Brisson, Brigitte A; Whiteside, Douglas P; Holmberg, David L

    2004-08-01

    A 4-year old, female spayed terrier was referred for hind end paresis that rapidly progressed to paralysis. Spinal radiographs revealed vertebral collapse and bony lysis. Myelography confirmed spinal cord compression and surgical exploration found an extradural soft tissue mass. Metastatic anal sac adenocarcinoma was diagnosed at postmortem examination.

  11. IR panoramic alerting sensor concepts and applications

    NASA Astrophysics Data System (ADS)

    de Jong, Arie N.; Schwering, Piet B. W.

    2003-09-01

    During the last decade, protection of military and civilian operational platforms against weapons like guns, grenades, missiles, Unmanned Combat Aerial (and surface) Vehicles (UCAV's) and mines, has been an issue of increased importance due to the improved kill-probability of these threats. The standard countermeasure package of armour, guns, decoys, jammers, camouflage nets and smokes is inadequate when not accompanied by a suitable sensor package, primarily consisting of an alerting device, triggering consecutive steps in the countermeasure-chain. In this process of alert four different detection techniques are considered: pre-alert, giving the directions of possible attack, detection of an action of attack, identification of the threat and finally the precise localization (3-D). The design of the alerting device is greatly depending on the platform, on which it will be used, the associated and affordable cost and the nature of the threat. A number of sensor packages, considered, developed and evaluated at TNO-FEL is presented for simple, medium size and large and expensive platforms. In recent years the requirements for these sensors have become more and more strigent due to the growing number of scenarios. The attack can practically be from any direction, implying the need for a large Field of Regard (FOR), the attack range can vary considerably and the type of threat can be very diverse, implying great flexibility and dynamic range and rapid response of the sensor. Especially the localization at short ranges is a challenging issue. Various configurations including advantages and drawbacks are discussed.

  12. Postural control system influences intrinsic alerting state.

    PubMed

    Barra, Julien; Auclair, Laurent; Charvillat, Agnès; Vidal, Manuel; Pérennou, Dominic

    2015-03-01

    Numerous studies using dual-task paradigms (postural and cognitive) have shown that postural control requires cognitive resources. However, the influence of postural control on attention components has never been directly addressed. Using the attention network test (ANT), which assesses specifically each of the 3 components of attention-alertness, orientation, and executive control-within a single paradigm, we investigated the effect of postural balance demand on these 3 components. Forty-two participants completed the ANT in 3 postural conditions: (a) supine, a very stable position; (b) sitting on a chair, an intermediate position; and (c) standing with feet lined up heel to toe, a very instable position known as the Romberg position. Our results revealed that the difficulty of postural control does modulate alerting in such a way that it improves with the level of instability of the position. Regarding the orienting and executive control components of attention, performance was not different when participants were standing upright or seated, whereas in the supine position, performance dropped. The strong and specific interaction between postural control and the alerting system suggests that these mechanisms may share parts of the underlying neural circuits. We discuss the possible implication of the locus coeruleus, known to be involved in both postural balance and alerting. Also, our findings concerning orienting and executive control systems suggest that supine posture could have a specific effect on cognitive activities. These effects are discussed in terms of particularities resulting from the supine position. PsycINFO Database Record (c) 2015 APA, all rights reserved.

  13. The effect of happiness and sadness on alerting, orienting, and executive attention.

    PubMed

    Finucane, Anne M; Whiteman, Martha C; Power, Mick J

    2010-05-01

    According to the attention network approach, attention is best understood in terms of three functionally and neuroanatomically distinct networks-alerting, orienting, and executive attention. An important question is whether the experience of emotion differentially influences the efficiency of these networks. This study examines 180 participants were randomly assigned to a happy, sad, or control condition and undertook a modified version of the Attention Network Test. The results showed no effect of happiness or sadness on alerting, orienting, or executive attention. However, sad participants showed reduced intrinsic alertness. This suggests that sadness reduces general alertness rather than impairing the efficiency of specific attention networks.

  14. Using electronic health record alerts to provide public health situational awareness to clinicians

    PubMed Central

    Lurio, Joseph; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations. PMID:20190067

  15. Using electronic health record alerts to provide public health situational awareness to clinicians.

    PubMed

    Lurio, Joseph; Morrison, Frances P; Pichardo, Michelle; Berg, Rachel; Buck, Michael D; Wu, Winfred; Kitson, Kwame; Mostashari, Farzad; Calman, Neil

    2010-01-01

    Alerting providers to public health situations requires timeliness and context-relevance, both lacking in current systems. Incorporating decision support tools into electronic health records may provide a way to deploy public health alerts to clinicians at the point of care. A timely process for responding to Health Alert Network messages sent by the New York City Department of Health and Mental Hygiene was developed by a network of community health centers. Alerts with order sets and recommended actions were created to notify primary care providers of local disease outbreaks. The process, effect, and lessons learned from alerts for Legionella, toxogenic E coli, and measles outbreaks are described. Electronic alerts have the potential to improve management of diseases during an outbreak, including appropriate laboratory testing, management guidance, and diagnostic assistance as well as to enhance bi-directional data exchange between clinical and public health organizations.

  16. Acquired fistula of the lacrimal sac and laisser-faire approach. Description of the natural history of acquired fistulas between the lacrimal sac and the skin occurring before planned endonasal dacryocystorhinostomy (DCR) and without any treatment of the fistula.

    PubMed

    Pison, A; Fau, J-L; Racy, E; Fayet, B

    2016-10-01

    The formation of a fistula between the lacrimal sac and the skin is a classic outcome of resistant lacrimal sac abscesses. There is currently no consensus about treatment in such cases. The goal of this study was to describe the natural history of acquired fistulas between the lacrimal sac and the skin, occurring before planned endonasal dacryocystorhinostomy (DCR) and without any treatment of the fistula. This prospective study was only descriptive and included patients between 1999 and 2012. The patients included were adults with a nasolacrimal duct (NLD) obstruction that was planned to be treated with endonasal DCR. A resistant lacrimal sac abscess appeared a few days before the planned surgery, and fistulized spontaneously despite medical treatment. The surgery was not delayed. The DCR was endoscopic. Nothing was done for the fistula. Its healing was spontaneous. The exclusion criteria were the following: congenital fistulas, post-traumatic and/or iatrogenic fistulas, fistulas which had regressed by the day of the surgery, postoperative follow-up less than 5 months, post-traumatic and/or iatrogenic fistulas, any history of previous DCR or any other lacrimal surgery, children. Twenty adults (25 cases) were included in the analysis. Mean age was 79 years old (from 41 to 90). The mean follow-up was 41 months (from 5 to 108 months). The fistula spontaneously disappeared in all cases, less than one month after it had appeared and in a permanent fashion. No unsightly scar developed. Spontaneously acquired fistulas between the lacrimal sac and the skin may occur in the natural course of abscessed acute dacryocystitis. Our study showed spontaneous healing of the fistula post-endoscopic DCR. Fistula excision in fistulous acute dacryocystitis does not seem essential to its healing. The laisser-faire approach appears adequate for aesthetic outcomes as well as for functional outcomes of DCR. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. Three-dimensional morphological analysis of intracranial aneurysms: a fully automated method for aneurysm sac isolation and quantification.

    PubMed

    Larrabide, Ignacio; Cruz Villa-Uriol, Maria; Cárdenes, Rubén; Pozo, Jose Maria; Macho, Juan; San Roman, Luis; Blasco, Jordi; Vivas, Elio; Marzo, Alberto; Hose, D Rod; Frangi, Alejandro F

    2011-05-01

    Morphological descriptors are practical and essential biomarkers for diagnosis and treatment selection for intracranial aneurysm management according to the current guidelines in use. Nevertheless, relatively little work has been dedicated to improve the three-dimensional quantification of aneurysmal morphology, to automate the analysis, and hence to reduce the inherent intra and interobserver variability of manual analysis. In this paper we propose a methodology for the automated isolation and morphological quantification of saccular intracranial aneurysms based on a 3D representation of the vascular anatomy. This methodology is based on the analysis of the vasculature skeleton's topology and the subsequent application of concepts from deformable cylinders. These are expanded inside the parent vessel to identify different regions and discriminate the aneurysm sac from the parent vessel wall. The method renders as output the surface representation of the isolated aneurysm sac, which can then be quantified automatically. The proposed method provides the means for identifying the aneurysm neck in a deterministic way. The results obtained by the method were assessed in two ways: they were compared to manual measurements obtained by three independent clinicians as normally done during diagnosis and to automated measurements from manually isolated aneurysms by three independent operators, nonclinicians, experts in vascular image analysis. All the measurements were obtained using in-house tools. The results were qualitatively and quantitatively compared for a set of the saccular intracranial aneurysms (n = 26). Measurements performed on a synthetic phantom showed that the automated measurements obtained from manually isolated aneurysms where the most accurate. The differences between the measurements obtained by the clinicians and the manually isolated sacs were statistically significant (neck width: p <0.001, sac height: p = 0.002). When comparing clinicians

  18. Evidence of the Most Stretchable Egg Sac Silk Stalk, of the European Spider of the Year Meta menardi

    PubMed Central

    Lepore, Emiliano; Marchioro, Andrea; Isaia, Marco; Buehler, Markus J.; Pugno, Nicola M.

    2012-01-01

    Spider silks display generally strong mechanical properties, even if differences between species and within the same species can be observed. While many different types of silks have been tested, the mechanical properties of stalks of silk taken from the egg sac of the cave spider Meta menardi have not yet been analyzed. Meta menardi has recently been chosen as the “European spider of the year 2012”, from the European Society of Arachnology. Here we report a study where silk stalks were collected directly from several caves in the north-west of Italy. Field emission scanning electron microscope (FESEM) images showed that stalks are made up of a large number of threads, each of them with diameter of 6.03±0.58 µm. The stalks were strained at the constant rate of 2 mm/min, using a tensile testing machine. The observed maximum stress, strain and toughness modulus, defined as the area under the stress-strain curve, are 0.64 GPa, 751% and 130.7 MJ/m3, respectively. To the best of our knowledge, such an observed huge elongation has never been reported for egg sac silk stalks and suggests a huge unrolling microscopic mechanism of the macroscopic stalk that, as a continuation of the protective egg sac, is expected to be composed by fibres very densely and randomly packed. The Weibull statistics was used to analyze the results from mechanical testing, and an average value of Weibull modulus (m) is deduced to be in the range of 1.5–1.8 with a Weibull scale parameter (σ 0) in the range of 0.33–0.41 GPa, showing a high coefficient of correlation (R2 = 0.97). PMID:22347380

  19. Saccades and memory: baseline associations of the King-Devick and SCAT2 SAC tests in professional ice hockey players.

    PubMed

    Galetta, Matthew S; Galetta, Kristin M; McCrossin, Jim; Wilson, James A; Moster, Stephen; Galetta, Steven L; Balcer, Laura J; Dorshimer, Gary W; Master, Christina L

    2013-05-15

    The Sports Concussion Assessment Tool 2 (SCAT2) and King-Devick (K-D) tests have both been proposed as sideline tools to detect sports-related concussion. We performed an exploratory analysis to determine the relation of SCAT2 components, particularly the Standardized Assessment of Concussion (SAC), to K-D test scores in a professional ice hockey team cohort during pre-season baseline testing. We also examined changes in scores for two athletes who developed concussion and had rinkside testing. A modified SCAT2 (no balance testing) and the K-D test, a brief measure of rapid number naming, were administered to 27 members of a professional ice hockey team during the 2011-2012 pre-season. Athletes with concussion also underwent rinkside testing. Lower (worse) scores for the SCAT2 SAC Immediate Memory Score and the overall SAC score were associated with greater (worse) times required to complete the K-D test at baseline. On average, for every 1-point reduction in SAC Immediate Memory Score, we found a corresponding increase (worsening) of K-D time score of 7.3s (95% CI 4.9, 9.7, p<0.001, R(2)=0.62, linear regression, accounting for age). For the overall SAC score, 1-point reductions were associated with K-D score worsening of 2.2s (95% CI 0.6, 3.8, p=0.01, R(2)=0.25, linear regression). In two players tested rinkside immediately following concussion, K-D test scores worsened from baseline by 4.2 and 6.4s. These athletes had no differences found for SCAT2 SAC components, but reported symptoms of concussion. In this study of professional athletes, scores for the K-D test, a measure for which saccadic (fast) eye movements are required for the task of rapid number naming, were associated with reductions in Immediate Memory at a pre-season baseline. Both working memory and saccadic eye movements share closely related anatomical structures, including the dorsolateral prefrontal cortex (DLPFC). A composite of brief rapid sideline tests, including SAC and K-D (and balance

  20. A fresh look at runway incursions: onboard surface movement awareness and alerting system based on SVS

    NASA Astrophysics Data System (ADS)

    Vernaleken, Christoph; Mihalic, Lamir; Güttler, Mathias; Klingauf, Uwe

    2006-05-01

    Increasing traffic density on the aerodrome surface due to the continuous worldwide growth in the number of flight operations does not only cause capacity and efficiency problems, but also increases the risk of serious incidents and accidents on the airport movement area. Of these, Runway Incursions are the by far most safety-critical. In fact, the worst-ever accident in civil aviation, the collision of two Boeing B747s on Tenerife in 1977 with 583 fatalities, was caused by a Runway Incursion. Therefore, various Runway Safety programs have recently been initiated around the globe, often focusing on ground-based measures such as improved surveillance. However, as a lack of flight crew situational awareness is a key causal factor in many Runway Incursion incidents and accidents, there is a strong need for an onboard solution, which should be capable of interacting cooperatively with ground-based ATM systems, such as A-SMGCS where available. This paper defines the concept of preventive and reactive Runway Incursion avoidance and describes a Surface Movement Awareness & Alerting System (SMAAS) designed to alert the flight crew if they are at risk of infringing a runway. Both the SVS flight deck displays and the corresponding alerting algorithms utilize an ED 99A/RTCA DO-272A compliant aerodrome database, as well as airport operational, traffic and clearance data received via ADS-B or other data links, respectively. The displays provide the crew with enhanced positional, operational, clearance and traffic awareness, and they are used to visualize alerts. A future enhancement of the system will provide intelligent alerting for conflicts caused by surrounding traffic.

  1. Notification of real-time clinical alerts generated by pharmacy expert systems.

    PubMed Central

    Miller, J. E.; Reichley, R. M.; McNamee, L. A.; Steib, S. A.; Bailey, T. C.

    1999-01-01

    We developed and implemented a strategy for notifying clinical pharmacists of alerts generated in real-time by two pharmacy expert systems: one for drug dosing and the other for adverse drug event prevention. Display pagers were selected as the preferred notification method and a concise, yet readable, format for displaying alert data was developed. This combination of real-time alert generation and notification via display pagers was shown to be efficient and effective in a 30-day trial. PMID:10566374

  2. [Non-linear research of alertness levels under sleep deprivation].

    PubMed

    Xue, Ranting; Zhou, Peng; Gao, Xiang; Dong, Xinming; Wang, Xiaolu; Ming, Dong; Qi, Hongzhi; Wang, Xuemin

    2014-06-01

    We applied Lempel-Ziv complexity (LZC) combined with brain electrical activity mapping (BEAM) to study the change of alertness under sleep deprivation in our research. Ten subjects were involved in 36 hours sleep deprivation (SD), during which spontaneous electroencephalogram (EEG) experiments and auditory evoked EEG experiments-Oddball were recorded once every 6 hours. Spontaneous and evoked EEG data were calculated and BEAMs were structured. Results showed that during the 36 hours of SD, alertness could be divided into three stages, i. e. the first 12 hours as the high stage, the middle 12 hours as the rapid decline stage and the last 12 hours as the low stage. During the period SD, LZC of Spontaneous EEG decreased over the whole brain to some extent, but remained consistent with the subjective scales. By BEAMs of event related potential, LZC on frontal cortex decreased, but kept consistent with the behavioral responses. Therefore, LZC can be effective to reflect the change of brain alertness. At the same time LZC could be used as a practical index to monitor real-time alertness because of its simple computation and fast calculation.

  3. Long-term outcomes and sac volume shrinkage after endovascular popliteal artery aneurysm repair.

    PubMed

    Piazza, M; Menegolo, M; Ferrari, A; Bonvini, S; Ricotta, J J; Frigatti, P; Grego, F; Antonello, M

    2014-08-01

    The aim was to evaluate long-term outcomes and sac volume shrinkage after endovascular popliteal artery aneurysm repair (EVPAR). This study was a retrospective review of all EVPAR cases between 1999 and 2012. Sac volume shrinkage, long-term patency, limb salvage, and survival were evaluated using Kaplan-Meier estimates. The association of anatomical and clinical characteristics with patency was evaluated using multivariate analysis. Forty-six EVPAR were carried out in 42 patients (mean age 78 years, 86% male; mean sac volume 45.5 ± 3.5 mL). In 93% of cases (n = 43) the procedure was elective, while in 7% of cases it was for rupture (n = 2) or acute thrombosis (n = 1). Of the 43 patients who underwent elective repair, 58% were asymptomatic and 42% symptomatic (14 claudication, 3 rest pain, and 1 compression symptoms). Technical success was 98%. Mean duration of follow-up was 56 ± 21 months. Primary patency at 1, 3, and 5 years was 82% (SE 2), 79% (SE 4), and 76% (SE 4), while secondary patency was 90% (SE 5), 85% (SE 4), and 82% (SE 1) respectively; at 5 years there was 98% limb salvage and an 84% survival rate. During follow-up 11 limbs had stent graft failure: six required conversion, one underwent amputation, and four continued with mild claudication. Of those with graft failure, 63% (7/11) occurred within the first year of follow-up. The mean aneurysm sac volume shrinkage between preoperative and 5-year post-procedure measurement was significant (45.5 ± 3.5 mL vs. 23.0 ± 5.0 mL; p < .001). Segment coverage >20 cm was a negative predictor for patency (HR 2.76; 95% CI 0.23; p = .032). EVPAR provides successful aneurysm exclusion with good long-term patency, excellent limb salvage, and survival rates. Close surveillance is nevertheless required, particularly during the first postoperative year. Patients requiring long segment coverage (>20 cm) may be at increased risk for failure. Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier

  4. Gaining consensus on family carer needs when caring for someone dying at home to develop the Carers' Alert Thermometer (CAT): a modified Delphi study.

    PubMed

    Knighting, Katherine; O'Brien, Mary R; Roe, Brenda; Gandy, Rob; Lloyd-Williams, Mari; Nolan, Mike; Jack, Barbara A

    2016-01-01

    To report a multi-phase modified Delphi study conducted with carers and professionals to identify the priority areas for inclusion in an alert screening tool for carers providing support to someone dying at home. Internationally, there is a growing emphasis on increasing choice for patients who wish to die at home which relies heavily on care provided by the unpaid family carers. Family carers can have high levels of unmet needs comprising their psychological and physical health and their ability to provide effective care and support. Development of an alert tool to identify carers' needs in everyday practice required identification and consensus of the priority areas of need for inclusion. Multi-phase modified Delphi study and instrument development. Qualitative and quantitative data collection took place between 2011-2013 with 111 carers and 93 professionals to identify carers' needs and gain consensus on the priority areas for inclusion in the alert tool. An expert panel stage and final evidence review post-Delphi were used. The Delphi panels had high levels of agreement and consensus. Ten areas of carer need across two themes of 'the current caring situation' and 'the carer's own health and well-being' were prioritized for inclusion in the alert tool. An optional end-of-life planning question was included following the final stages. The results provide evidence of carers' needs to be assessed, areas for consideration in the education of those who support carers and someone dying at home and targeting of services, while demonstrating the usefulness and adaptability of the Delphi method. © 2015 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.

  5. Evaluation of medication alerts in electronic health records for compliance with human factors principles

    PubMed Central

    Phansalkar, Shobha; Zachariah, Marianne; Seidling, Hanna M; Mendes, Chantal; Volk, Lynn; Bates, David W

    2014-01-01

    Introduction Increasing the adoption of electronic health records (EHRs) with integrated clinical decision support (CDS) is a key initiative of the current US healthcare administration. High over-ride rates of CDS alerts strongly limit these potential benefits. As a result, EHR designers aspire to improve alert design to achieve better acceptance rates. In this study, we evaluated drug–drug interaction (DDI) alerts generated in EHRs and compared them for compliance with human factors principles. Methods We utilized a previously validated questionnaire, the I-MeDeSA, to assess compliance with nine human factors principles of DDI alerts generated in 14 EHRs. Two reviewers independently assigned scores evaluating the human factors characteristics of each EHR. Rankings were assigned based on these scores and recommendations for appropriate alert design were derived. Results The 14 EHRs evaluated in this study received scores ranging from 8 to 18.33, with a maximum possible score of 26. Cohen's κ (κ=0.86) reflected excellent agreement among reviewers. The six vendor products tied for second and third place rankings, while the top system and bottom five systems were home-grown products. The most common weaknesses included the absence of characteristics such as alert prioritization, clear and concise alert messages indicating interacting drugs, actions for clinical management, and a statement indicating the consequences of over-riding the alert. Conclusions We provided detailed analyses of the human factors principles which were assessed and described our recommendations for effective alert design. Future studies should assess whether adherence to these recommendations can improve alert acceptance. PMID:24780721

  6. Management of Patient-Reported Outcome (PRO) Alerts in Clinical Trials: A Cross Sectional Survey.

    PubMed

    Kyte, Derek; Ives, Jonathan; Draper, Heather; Calvert, Melanie

    2016-01-01

    Assessment of patient-reported outcomes (PROs) provides valuable information to inform patient-centered care, but may also reveal 'PRO alerts': psychological distress or physical symptoms that may require an immediate response. Ad-hoc management of PRO alerts in clinical trials may result in suboptimal patient care or potentially bias trial results. To gain greater understanding of current practice in PRO alert management we conducted a national survey of personnel involved in clinical trials with a PRO endpoint. We conducted a national cross-sectional survey of 767 UK-based research nurses, data managers/coordinators, trial managers and chief/principal investigators involved in clinical trials using PROs. Respondents were self-selected volunteers from a non-randomised sample of eligible individuals recruited via 55 UK Clinical Research Collaboration Registered Clinical Trials Units and 19 Comprehensive Local Research Networks. Questions centred on the proportion of trial personnel encountering alerts, how staff responded to PRO alerts and whether current guidance was deemed sufficient to support research personnel. We undertook descriptive analyses of the quantitative data and directed thematic analysis of free-text comments. 20% of research nurses did not view completed PRO questionnaires and were not in a position to discover alerts, 39-50% of the remaining respondent group participants reported encountering PRO alerts. Of these, 83% of research nurses and 54% of data managers/trial coordinators reported taking action to assist the trial participant, but less than half were able to record the intervention in the trial documentation. Research personnel reported current PRO alert guidance/training was insufficient. Research personnel are intermittently exposed to PRO alerts. Some intervene to help trial participants, but are not able to record this intervention in the trial documentation, risking co-intervention bias. Other staff do not check PRO information

  7. Metastatic anal sac adenocarcinoma in a dog presenting for acute paralysis

    PubMed Central

    2004-01-01

    Abstract A 4-year old, female spayed terrier was referred for hind end paresis that rapidly progressed to paralysis. Spinal radiographs revealed vertebral collapse and bony lysis. Myelography confirmed spinal cord compression and surgical exploration found an extradural soft tissue mass. Metastatic anal sac adenocarcinoma was diagnosed at postmortem examination. PMID:15368742

  8. Dopamine in motivational control: rewarding, aversive, and alerting

    PubMed Central

    Bromberg-Martin, Ethan S.; Matsumoto, Masayuki; Hikosaka, Okihide

    2010-01-01

    SUMMARY Midbrain dopamine neurons are well known for their strong responses to rewards and their critical role in positive motivation. It has become increasingly clear, however, that dopamine neurons also transmit signals related to salient but non-rewarding experiences such as aversive and alerting events. Here we review recent advances in understanding the reward and non-reward functions of dopamine. Based on this data, we propose that dopamine neurons come in multiple types that are connected with distinct brain networks and have distinct roles in motivational control. Some dopamine neurons encode motivational value, supporting brain networks for seeking, evaluation, and value learning. Others encode motivational salience, supporting brain networks for orienting, cognition, and general motivation. Both types of dopamine neurons are augmented by an alerting signal involved in rapid detection of potentially important sensory cues. We hypothesize that these dopaminergic pathways for value, salience, and alerting cooperate to support adaptive behavior. PMID:21144997

  9. Effect of aluminum on bidirectional calcium flux in rat everted intestinal sacs.

    PubMed

    Adler, A J; Zara, C; Berlyne, G M

    1989-09-01

    The effect of aluminum on intestinal calcium absorption was determined in male Sprague-Dawley rats using an everted intestinal sac technique. Bidirectional calcium flux in the duodena and ilea of normal rats was assessed by means of dual calcium isotopes. Two micromolar aluminum significantly inhibited net calcium absorption (J net) in the duodenum through suppression of mucosato-serosa flux (J m----s). Jm----s was reduced from 2.21 +/- 0.50 mumol Ca.h-1.g wet wt-1 in controls to 0.93 +/- 0.35 mumol Ca.h-1.g-1 in aluminum exposed sacs, and Jnet was reduced from 1.88 +/- 0.14 mumol Ca.h-1.g-1 to 0.55 +/- 0.41 mumol Ca.h-1.g-1 (P less than 0.001). Serosa-to-mucosa calcium flux (Js----m) was not similarly influenced by aluminum. Inhibition of Jm----s occurred whether aluminum was initially present on the mucosal or serosal side of the duodenal sac and inhibition of Jnet calcium by 2 muM A1 occurred at all ambient concentrations of calcium studied. In the ileum, aluminum had no effect on any component of calcium flux. Aluminum did not induce any suppression of glucose transport in either the duodenum or ileum, suggesting that the effect on calcium transport is relatively specific. These results suggest that aluminum inhibits calcium absorption in the duodenum through an effect on active mucosa-to-serosa transport, but has no effect on ileal calcium absorption, which in the rat is not mediated by an active process.

  10. A Critical Review of Research on the Alert Program®

    ERIC Educational Resources Information Center

    Gill, Kamaldeep; Thompson-Hodgetts, Sandra; Rasmussen, Carmen

    2018-01-01

    To evaluate the strength of evidence for the effectiveness, feasibility, and appropriateness of the Alert Program®. Multiple databases were systematically searched for peer-reviewed, English-language articles that evaluated the Alert Program®. Six articles met the inclusion criteria. The strength of evidence ranged from weak to moderate using the…

  11. Silver Alerts and the Problem of Missing Adults with Dementia

    ERIC Educational Resources Information Center

    Carr, Dawn; Muschert, Glenn W.; Kinney, Jennifer; Robbins, Emily; Petonito, Gina; Manning, Lydia; Brown, J. Scott

    2010-01-01

    In the months following the introduction of the National AMBER (America's Missing: Broadcast Emergency Response) Alert plan used to locate missing and abducted children, Silver Alert programs began to emerge. These programs use the same infrastructure and approach to find a different missing population, cognitively impaired older adults. By late…

  12. Immunohistochemical characterization of neuroendocrine differentiation of canine anal sac glandular tumours.

    PubMed

    Suzuki, K; Morita, R; Hojo, Y; Nomura, K; Shibutani, M; Mitsumori, K

    2013-01-01

    Histological features and expression of neuroendocrine markers were examined in 69 samples of canine anal sac glandular carcinomas (ASGCs). The tumours were classified into solid, rosette and tubular types and mixtures of these types. Tumour-associated death in dogs with solid tumours and mixed tumours with solid components was higher than in dogs with rosette and tubular type tumours. Chromogranin A immunoreactivity was observed in 28 of 69 samples (40.6%) irrespective of histological type and was localized to the marginal areas of the tumour nest and the basal areas of the tubular and rosette structures. Neuron-specific enolase immunoreactivity in neoplastic epithelial cells was observed in 32 cases (46.4%) and was less frequently observed in the tubular type (14.3%). Synaptophysin expression was present in 15.9% of cases and was least frequent in the tubular type. Twenty-one of the 69 samples expressed more than two neuroendocrine markers and were classified as carcinomas with neuroendocrine differentiation. There was no relationship between neuroendocrine differentiation and clinical outcome. These results suggest that some ASGCs have neuroendocrine differentiation regardless of histological pattern, but clinical outcome is more related to the histological pattern than to neuroendocrine differentiation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Primary Care Providers' Opening of Time-Sensitive Alerts Sent to Commercial Electronic Health Record InBaskets.

    PubMed

    Cutrona, Sarah L; Fouayzi, Hassan; Burns, Laura; Sadasivam, Rajani S; Mazor, Kathleen M; Gurwitz, Jerry H; Garber, Lawrence; Sundaresan, Devi; Houston, Thomas K; Field, Terry S

    2017-11-01

    Time-sensitive alerts are among the many types of clinical notifications delivered to physicians' secure InBaskets within commercial electronic health records (EHRs). A delayed alert review can impact patient safety and compromise care. To characterize factors associated with opening of non-interruptive time-sensitive alerts delivered into primary care provider (PCP) InBaskets. We analyzed data for 799 automated alerts. Alerts highlighted actionable medication concerns for older patients post-hospital discharge (2010-2011). These were study-generated alerts sent 3 days post-discharge to InBaskets for 75 PCPs across a multisite healthcare system, and represent a subset of all urgent InBasket notifications. Using EHR access and audit logs to track alert opening, we performed bivariate and multivariate analyses calculating associations between patient characteristics, provider characteristics, contextual factors at the time of alert delivery (number of InBasket notifications, weekday), and alert opening within 24 h. At the time of alert delivery, the PCPs had a median of 69 InBasket notifications and had received a median of 379.8 notifications (IQR 295.0, 492.0) over the prior 7 days. Of the 799 alerts, 47.1% were opened within 24 h. Patients with longer hospital stays (>4 days) were marginally more likely to have alerts opened (OR 1.48 [95% CI 1.00-2.19]). Alerts delivered to PCPs whose InBaskets had a higher number of notifications at the time of alert delivery were significantly less likely to be opened within 24 h (top quartile >157 notifications: OR 0.34 [95% CI 0.18-0.61]; reference bottom quartile ≤42). Alerts delivered on Saturdays were also less likely to be opened within 24 h (OR 0.18 [CI 0.08-0.39]). The number of total InBasket notifications and weekend delivery may impact the opening of time-sensitive EHR alerts. Further study is needed to support safe and effective approaches to care team management of InBasket notifications.

  14. Real-Time Mapping alert system; user's manual

    USGS Publications Warehouse

    Torres, L.A.

    1996-01-01

    The U.S. Geological Survey has an extensive hydrologic network that records and transmits precipitation, stage, discharge, and other water- related data on a real-time basis to an automated data processing system. Data values are recorded on electronic data collection platforms at field monitoring sites. These values are transmitted by means of orbiting satellites to receiving ground stations, and by way of telecommunication lines to a U.S. Geological Survey office where they are processed on a computer system. Data that exceed predefined thresholds are identified as alert values. These alert values can help keep water- resource specialists informed of current hydrologic conditions. The current alert status at monitoring sites is of critical importance during floods, hurricanes, and other extreme hydrologic events where quick analysis of the situation is needed. This manual provides instructions for using the Real-Time Mapping software, a series of computer programs developed by the U.S. Geological Survey for quick analysis of hydrologic conditions, and guides users through a basic interactive session. The software provides interactive graphics display and query of real-time information in a map-based, menu-driven environment.

  15. Healthcare-associated infection surveillance and bedside alerts.

    PubMed

    Adlassnig, Klaus-Peter; Berger, Angelika; Koller, Walter; Blacky, Alexander; Mandl, Harald; Unterasinger, Lukas; Rappelsberger, Andrea

    2014-01-01

    Expectations and requirements concerning the identification and surveillance of healthcare-associated infections (HAIs) are increasing, calling for differentiated automated approaches. In an attempt to bridge the "definition swamp" of these infections and serve the needs of different users, we improved the monitoring of nosocomial infections (MONI) software to create better surveillance reports according to consented national and international definitions, as well as produce infection overviews on complex clinical matters including alerts for the clinician's ward and bedside work. MONI contains and processes surveillance definitions for intensive-care-unit-acquired infections from the European Centre for Disease Prevention and Control, Sweden, as well as the Centers for Disease Control and Prevention, USA. The latest release of MONI also includes KISS criteria of the German National Reference Center for Surveillance of Nosocomial Infections. In addition to these "classic" surveillance criteria, clinical alert criteria--which are similar but not identical to the surveillance criteria--were established together with intensivists. This is an important step to support both infection control and clinical personnel; and--last but not least--to foster co-evolution of the two groups of definitions: surveillance and alerts.

  16. Steatorrhoea in rats with an intestinal cul-de-sac

    PubMed Central

    Hoet, P. P.; Eyssen, H.

    1964-01-01

    Steatorrhoea in rats with an intestinal cul-de-sac is mainly due to malabsorption of alimentary fats but faecal lipids of endogenous origin are also increased. Steatorrhoea depends on the site of the blind loop in the small intestine and is mainly caused by bacterial proliferation in the lumen of the gut. The aetiological role of Gram-positive anaerobic microbes, especially Clostridium welchii, is suggested. ImagesFIG. 3FIG. 4FIG. 5FIG. 6 PMID:14209913

  17. Conditional suicide system of Escherichia coli released into soil that uses the Bacillus subtilis sacB gene.

    PubMed Central

    Recorbet, G; Robert, C; Givaudan, A; Kudla, B; Normand, P; Faurie, G

    1993-01-01

    The sacB gene from Bacillus subtilis confers sucrose sensitivity upon gram-negative bacteria. The gene was investigated for use as a potential conditional suicide system for Escherichia coli released into soil. To ensure against the loss of the cell death function encoded under nonselective conditions, the nptI-sacR-B suicide cassette was inserted into the E. coli chromosome by using a circular nonreplicative integration vector. Stability studies yielded no loss of the suicide cassette in the integrated E. coli EL1026 strain. sacB induction in the absence of a selective pressure resulted in a lysis efficiency of up to 99.9%. The microcosm experiments confirmed the ability of the suicide cassette to limit the growth and reduce the survival of E. coli strains released into soil. Sucrose addition to sterile soil resulted in a 10(-3)-fold reduction of the final E. coli population density. sacB induction prevented the proliferation and triggered the rapid disappearance of E. coli from natural soil. Mutation to sucrose tolerance occurred at a frequency of 10(-5), making E. coli EL1026 a potential counterselectable donor strain for gene transfer studies. Specificity and potential adaptability to a wide range of gram-negative bacteria are additional conveniences of this conditional suicide system for the containment and counterselection of engineered microorganisms. PMID:8517732

  18. Conditional suicide system of Escherichia coli released into soil that uses the Bacillus subtilis sacB gene.

    PubMed

    Recorbet, G; Robert, C; Givaudan, A; Kudla, B; Normand, P; Faurie, G

    1993-05-01

    The sacB gene from Bacillus subtilis confers sucrose sensitivity upon gram-negative bacteria. The gene was investigated for use as a potential conditional suicide system for Escherichia coli released into soil. To ensure against the loss of the cell death function encoded under nonselective conditions, the nptI-sacR-B suicide cassette was inserted into the E. coli chromosome by using a circular nonreplicative integration vector. Stability studies yielded no loss of the suicide cassette in the integrated E. coli EL1026 strain. sacB induction in the absence of a selective pressure resulted in a lysis efficiency of up to 99.9%. The microcosm experiments confirmed the ability of the suicide cassette to limit the growth and reduce the survival of E. coli strains released into soil. Sucrose addition to sterile soil resulted in a 10(-3)-fold reduction of the final E. coli population density. sacB induction prevented the proliferation and triggered the rapid disappearance of E. coli from natural soil. Mutation to sucrose tolerance occurred at a frequency of 10(-5), making E. coli EL1026 a potential counterselectable donor strain for gene transfer studies. Specificity and potential adaptability to a wide range of gram-negative bacteria are additional conveniences of this conditional suicide system for the containment and counterselection of engineered microorganisms.

  19. Infant Responsiveness, Alertness, Hemoglobin and Growth in Rural Sidama, Ethiopia

    PubMed Central

    Aubuchon-Endsley, Nicki L.; Grant, Stephanie L.; Thomas, David G.; Kennedy, Tay S.; Berhanu, Getenesh; Stoecker, Barbara J.; Hubbs-Tait, Laura; Hambidge, K. Michael

    2011-01-01

    Several recent studies have supported relations between infant behavior (alertness and responsiveness) and nutrition (e.g. Dempsey 2008, Wachs et al 2005) in addition to investigating infant behavior within the context of changes in iron status over time (e.g. Black et al. 2004, Murray-Kolb & Beard 2009). Existing research is typically limited to investigation of the effects of a single vitamin or mineral and no studies have been found that examined the influence that early alertness and responsiveness have on growth in early infancy, despite the fact that relations between behavior and nutritional status may be bidirectional (Hulthén 2003). The current study used a sample of Ethiopian infants and investigated anthropometrics, hemoglobin, the frequency of alertness, and the frequency of responsiveness at 6 and 9 months of age. Six-month weight-for-age predicted 9-month frequency of alertness, while 6-month hemoglobin predicted 9-month frequency of responsiveness. Compared to responsive infants, non-responsive infants at 6 months remained more non-responsive at 9 months, though weight-for-age for both groups converged at 9 months. Results support relations between nutrition and behavior (alertness and responsiveness) and provide evidence of a potentially useful tool (the Laboratory Temperament Assessment Battery [Lab-TAB]) that was adapted to evaluate these relations in Ethiopia. PMID:22233352

  20. Optimizing the response to surveillance alerts in automated surveillance systems.

    PubMed

    Izadi, Masoumeh; Buckeridge, David L

    2011-02-28

    Although much research effort has been directed toward refining algorithms for disease outbreak alerting, considerably less attention has been given to the response to alerts generated from statistical detection algorithms. Given the inherent inaccuracy in alerting, it is imperative to develop methods that help public health personnel identify optimal policies in response to alerts. This study evaluates the application of dynamic decision making models to the problem of responding to outbreak detection methods, using anthrax surveillance as an example. Adaptive optimization through approximate dynamic programming is used to generate a policy for decision making following outbreak detection. We investigate the degree to which the model can tolerate noise theoretically, in order to keep near optimal behavior. We also evaluate the policy from our model empirically and compare it with current approaches in routine public health practice for investigating alerts. Timeliness of outbreak confirmation and total costs associated with the decisions made are used as performance measures. Using our approach, on average, 80 per cent of outbreaks were confirmed prior to the fifth day of post-attack with considerably less cost compared to response strategies currently in use. Experimental results are also provided to illustrate the robustness of the adaptive optimization approach and to show the realization of the derived error bounds in practice. Copyright © 2011 John Wiley & Sons, Ltd.

  1. Diversion Alert: 1-Year Evaluation Across Northern New England, 2013–2014

    PubMed Central

    Desrosiers, Clare

    2016-01-01

    This report describes Diversion Alert, a unique online tool aimed at reducing misuse and diversion of prescription drugs, and reports the results of a 1-year evaluation of Diversion Alert’s impact in Maine. We used a quasi-experimental research design to compare survey data in Maine with those of neighboring states (New Hampshire and Vermont, 2013 and 2014). Compared with their counterparts in New Hampshire and Vermont who did not use Diversion Alert, prescribers and pharmacists in Maine who used Diversion Alert increased their communication with patients and other providers involved in their patients’ care, became aware of patients arrested for prescription drugs possession or diversion, used best practices associated with prevention or detection of addiction and diversion more frequently, and attributed positive changes in their prescribing practices to Diversion Alert. In combination with other state and federal programs, Diversion Alert may be an effective tool to help prevent the misuse of opioid medications. PMID:27880633

  2. SAC3B, a central component of the mRNA export complex TREX-2, is required for prevention of epigenetic gene silencing in Arabidopsis

    PubMed Central

    Yang, Yu; La, Honggui; Tang, Kai; Miki, Daisuke; Yang, Lan; Wang, Bangshing; Duan, Cheng-Guo; Nie, Wenfeng; Wang, Xingang; Wang, Siwen; Pan, Yufeng; Tran, Elizabeth J.; An, Lizhe; Zhang, Huiming; Zhu, Jian-Kang

    2017-01-01

    Epigenetic regulation is important for organismal development and response to the environment. Alteration in epigenetic status has been known mostly from the perspective of enzymatic actions of DNA methylation and/or histone modifications. In a genetic screen for cellular factors involved in preventing epigenetic silencing, we isolated an Arabidopsis mutant defective in SAC3B, a component of the conserved TREX-2 complex that couples mRNA transcription with nuleo-cytoplasmic export. Arabidopsis SAC3B dysfunction causes gene silencing at transgenic and endogenous loci, accompanied by elevation in the repressive histone mark H3K9me2 and by reduction in RNA polymerase Pol II occupancy. SAC3B dysfunction does not alter promoter DNA methylation level of the transgene d35S::LUC, although the DNA demethylase ROS1 is also required for d35S::LUC anti-silencing. THP1 and NUA were identified as SAC3B-associated proteins whose mutations also caused d35S::LUC silencing. RNA-DNA hybrid exists at the repressed loci but is unrelated to gene suppression by the sac3b mutation. Genome-wide analyses demonstrated minor but clear involvement of SAC3B in regulating siRNAs and DNA methylation, particularly at a group of TAS and TAS-like loci. Together our results revealed not only a critical role of mRNA-export factors in transcriptional anti-silencing but also the contribution of SAC3B in shaping plant epigenetic landscapes. PMID:27672037

  3. A new approach to monitoring and alerting congestion in airspace sectors

    DOT National Transportation Integrated Search

    2014-09-28

    The Federal Aviation Administration (FAA) Traffic Flow Management System (TFMS)currently declares an alert for any 15 minute interval in which the predicted demand exceeds the Monitor/Alert Parameter (MAP)for any airport, sector, or fix. For airports...

  4. Phasic and tonic alerting in mild cognitive impairment: A preliminary study.

    PubMed

    Martella, Diana; Manzanares, Salvadora; Campoy, Guillermo; Roca, Javier; Antúnez, Carmen; Fuentes, Luis J

    2014-01-01

    In this preliminary study we assessed the functioning of the different attentional networks in mild cognitive impairment (MCI) patients, taking as theoretical framework the Posner's cognitive neuroscience approach. Two groups of participants were tested in a single short experiment: 20 MCI patients (6 amnestic, 6 non-amnestic and 8 multiple-domain) and 18 healthy matched controls (HC). For attentional assessment we used a version of the Attention Network Test (the ANTI-V) that provided not only a score of the orienting, the executive, and the alerting networks and their interactions, but also an independent measure of vigilance (tonic alerting). The results showed that all subtypes of MCI patients exhibited a selective impairment in the tonic component of alerting, as indexed by a decrease in the d' sensitivity index, and their performance in executive network increased up to the HC group level when phasic alerting was provided by a warning tone. Our findings suggest that a core attentional deficit, especially the endogenous component of alerting, may significantly contribute to the behavioral and cognitive deficits associated with MCI. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

    NASA Technical Reports Server (NTRS)

    Panangadan, Anand V. (Inventor); Monacos, Steve P. (Inventor)

    2015-01-01

    A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

  6. For whom the bell tolls: Silver Alerts raise concerns regarding individual rights and governmental interests.

    PubMed

    Wasser, Tobias D; Fox, Patrick K

    2013-01-01

    The Silver Alert system was initially created to help protect missing persons who have cognitive impairments, particularly the elderly. The Silver Alert is modeled after the Amber Alert, created to help locate and safeguard missing children. Unlike the Amber Alert, however, in most states the Silver Alert applies to the elderly, adults with a mental impairment, or both, depending on the state. The goal of the Silver Alert system is the quick dissemination of information about missing persons to law enforcement personnel as well as to the general public. Previously, states notified law enforcement personnel of missing persons through teletype to other public safety jurisdictions to enlist their assistance in the retrieval of the missing person. Silver Alert programs substantially expand the notification to include the general public, who receive information through radio and television broadcasts as well as highway billboards. The programs serve a legitimate governmental interest by protecting a vulnerable population from possible harm. Yet, the implementation of these alerts can have unintended consequences, including the possible violation of an individual's right to privacy. Such consequences require careful consideration.

  7. Diurnal Spectral Sensitivity of the Acute Alerting Effects of Light

    PubMed Central

    Rahman, Shadab A.; Flynn-Evans, Erin E.; Aeschbach, Daniel; Brainard, George C.; Czeisler, Charles A.; Lockley, Steven W.

    2014-01-01

    Study Objectives: Previous studies have demonstrated short-wavelength sensitivity for the acute alerting response to nocturnal light exposure. We assessed daytime spectral sensitivity in alertness, performance, and waking electroencephalogram (EEG). Design: Between-subjects (n = 8 per group). Setting: Inpatient intensive physiologic monitoring unit. Participants: Sixteen healthy young adults (mean age ± standard deviation = 23.8 ± 2.7 y). Interventions: Equal photon density exposure (2.8 × 1013 photons/cm2/s) to monochromatic 460 nm (blue) or 555 nm (green) light for 6.5 h centered in the middle of the 16-h episode of wakefulness during the biological day. Results were compared retrospectively to 16 individuals who were administered the same light exposure during the night. Measurements and Results: Daytime and nighttime 460-nm light exposure significantly improved auditory reaction time (P < 0.01 and P < 0.05, respectively) and reduced attentional lapses (P < 0.05), and improved EEG correlates of alertness compared to 555-nm exposure. Whereas subjective sleepiness ratings did not differ between the two spectral conditions during the daytime (P > 0.05), 460-nm light exposure at night significantly reduced subjective sleepiness compared to 555-nm light exposure at night (P < 0.05). Moreover, nighttime 460-nm exposure improved alertness to near-daytime levels. Conclusions: The alerting effects of short-wavelength 460-nm light are mediated by counteracting both the circadian drive for sleepiness and homeostatic sleep pressure at night, but only via reducing the effects of homeostatic sleep pressure during the day. Citation: Rahman SA; Flynn-Evans EE; Aeschbach D; Brainard GC; Czeisler CA; Lockley SW. Diurnal spectral sensitivity of the acute alerting effects of light. SLEEP 2014;37(2):271-281. PMID:24501435

  8. Solar radiation alert system : final report.

    DOT National Transportation Integrated Search

    2009-03-01

    The Solar Radiation Alert (SRA) system continuously evaluates measurements of high-energy protons made by instruments on GOES satellites. If the measurements indicate a substantial elevation of effective dose rates at aircraft flight altitudes, the C...

  9. CEI-PEA Alert, Summer 2006

    ERIC Educational Resources Information Center

    Center for Educational Innovation - Public Education Association, 2006

    2006-01-01

    The "CEI-PEA Alert" is an advocacy newsletter that deals with topics of interest to all concerned with the New York City public schools. This issue includes: (1) Practical Skills & High Academic Standards: Career Technical Education; (2) Parents: Help Your Children Gain "Soft Skills" for the Workforce; (3) Culinary Arts…

  10. Reduction in alert fatigue in an assisted electronic prescribing system, through the Lean Six Sigma methodology.

    PubMed

    Cuéllar Monreal, Mª Jesús; Reig Aguado, Jorge; Font Noguera, Isabel; Poveda Andrés, José Luis

    2017-01-01

    To reduce the alert fatigue in our Assisted Electronic Prescribing System (AEPS), through the Lean Six Sigma (LSS) methodology. An observational (transversal) and retrospective study, in a general hospital with 850 beds and AEPS. The LSS methodology was followed in order to evaluate the alert fatigue situation in the AEPS system, to implement improvements, and to assess outcomes. The alerts generated during two trimesters studied (before and after the intervention) were analyzed. In order to measure the qualitative indicators, the most frequent alert types were analyzed, as well as the molecules responsible for over 50% of each type of alert. The action by the prescriber was analyzed in a sample of 496 prescriptions that generated such alerts. For each type of alert and molecule, there was a prioritization of the improvements to be implemented according to the alert generated and its quality. A second survey evaluated the pharmacist action for the alerts most highly valued by physicians. The problem, the objective, the work team and the project schedule were defined. A survey was designed in order to understand the opinion of the client about the alert system in the program. Based on the surveys collected (n = 136), the critical characteristics and the quanti/qualitative indicators were defined. Sixty (60) fields in the alert system were modified, corresponding to 32 molecules, and this led to a 28% reduction in the total number of alerts. Regarding quality indicators, false po sitive results were reduced by 25% (p < 0.05), 100% of those alerts ignored with justification were sustained, and there were no significant differences in user adherence to the system. The project improvements and outcomes were reviewed by the work team. LSS methodology has demonstrated being a valid tool for the quantitative and qualitative improvement of the alert system in an Assisted Electronic Prescription Program, thus reducing alert fatigue. Copyright AULA MEDICA EDICIONES 2014

  11. Characterization of calcium carbonate crystals in pigeon yolk sacs with different incubation times.

    PubMed

    Song, Juan; Cheng, Haixia; Shen, Xinyu; Hu, Jingxiao; Tong, Hua

    2014-05-01

    Calcium carbonate crystals are known to form in the yolk sacs of fertile pigeon eggs at late stages of incubation. The composition and structure of these crystals were investigated, the crystallization environment was inspected, and the physical chemistry constants of the yolk fluid were determined through the incubation period. Polarized light microscopy was used to observe the generation and distribution of calcium carbonate crystals in the yolk sac. In addition, X-ray diffraction was employed to analyze the composition and crystal phase of the yolk sac. A decalcification and deproteination method was established to analyze the ultrastructure and composition of the crystals, as well as the internal relationship between inorganic and organic phases of the crystals. Additionally, scanning electron microscopy, transmission electron microscopy, X-ray energy dispersive spectroscopy, and Fourier transform infrared spectroscopy were used to evaluate the characteristics of the crystals. Our results demonstrated that the calcium carbonate crystals were mainly composed of vaterite and calcite, with vaterite being the major component. Vaterite, a type of biomaterial generated by an organic template control, presented as a concentric hierarchical spherical structure. The organic nature of the biomaterial prevented vaterite from transforming into calcite, which is more thermodynamically stable than vaterite. Additionally, the configuration, size, and aggregation of vaterite were also mediated by the organic template. This bio-vaterite was found during the incubation period and is valuable in calcium transport during embryonic development. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Electronic Health Record Alert-Related Workload as a Predictor of Burnout in Primary Care Providers.

    PubMed

    Gregory, Megan E; Russo, Elise; Singh, Hardeep

    2017-07-05

    Electronic health records (EHRs) have been shown to increase physician workload. One EHR feature that contributes to increased workload is asynchronous alerts (also known as inbox notifications) related to test results, referral responses, medication refill requests, and messages from physicians and other health care professionals. This alert-related workload results in negative cognitive outcomes, but its effect on affective outcomes, such as burnout, has been understudied. To examine EHR alert-related workload (both objective and subjective) as a predictor of burnout in primary care providers (PCPs), in order to ultimately inform interventions aimed at reducing burnout due to alert workload. A cross-sectional questionnaire and focus group of 16 PCPs at a large medical center in the southern United States. Subjective, but not objective, alert workload was related to two of the three dimensions of burnout, including physical fatigue (p = 0.02) and cognitive weariness (p = 0.04), when controlling for organizational tenure. To reduce alert workload and subsequent burnout, participants indicated a desire to have protected time for alert management, fewer unnecessary alerts, and improvements to the EHR system. Burnout associated with alert workload may be in part due to subjective differences at an individual level, and not solely a function of the objective work environment. This suggests the need for both individual and organizational-level interventions to improve alert workload and subsequent burnout. Additional research should confirm these findings in larger, more representative samples.

  13. Randomized control trial of computer-based training targeting alertness in older adults: the ALERT trial protocol.

    PubMed

    VanVleet, Thomas; Voss, Michelle; Dabit, Sawsan; Mitko, Alex; DeGutis, Joseph

    2018-05-03

    Healthy aging is associated with a decline in multiple functional domains including perception, attention, short and long-term memory, reasoning, decision-making, as well as cognitive and motor control functions; all of which are significantly modulated by an individual's level of alertness. The control of alertness also significantly declines with age and contributes to increased lapses of attention in everyday life, ranging from minor memory slips to a lack of vigilance and increased risk of falls or motor-vehicle accidents. Several experimental behavioral therapies designed to remediate age-related cognitive decline have been developed, but differ widely in content, method and dose. Preliminary studies demonstrate that Tonic and Phasic Alertness Training (TAPAT) can improve executive functions in older adults and may be a useful adjunct treatment to enhance benefits gained in other clinically validated treatments. The purpose of the current trial (referred to as the Attention training for Learning Enhancement and Resilience Trial or ALERT) is to compare TAPAT to an active control training condition, include a larger sample of patients, and assess both cognitive and functional outcomes. We will employ a multi-site, longitudinal, blinded randomized controlled trial (RCT) design with a target sample of 120 patients with age-related cognitive decline. Patients will be asked to complete 36 training sessions remotely (30 min/day, 5 days a week, over 3 months) of either the experimental TAPAT training program or an active control computer games condition. Patients will be assessed on a battery of cognitive and functional outcomes at four time points, including: a) immediately before training, b) halfway through training, c) within forty-eight hours post completion of total training, and d) after a three-month no-contact period post completion of total training, to assess the longevity of potential training effects. The strengths of this protocol are that it tests an

  14. Human Chorionic Gonadotropine in Cul-de-sac Fluid in Tubal Ectopic Pregnacy; A New Diagnostic Approach.

    PubMed

    Karahasanoglu, Ayse; Uzun, Isil; Ozdemir, Mucize; Yazicioglu, Fehmi

    2016-04-01

    Although new diagnostic abilities are being utilised increasingly yet early detection of tubal pregnancy remains a challenge. The use of highly sensitive hCG kits has facilitated the early diagnosis of a pregnancy. But it takes time to determine the localisation of the pregnancy. Early diagnosis of ectopic pregnancy may reduce the morbidity of ectopic pregnancy. This study was conducted to analyse the cul-de-sac and serum βhCG ratio in tubal ectopic pregnancy cases which may be a new diagnostic approach for ectopic pregnancy. Between January 2004 and July 2011, 263 patients with ectopic pregnancy were included in the study. Risk factors of patients and treatment modalities were evaluated. hCG was measured in peripheral serum and peritoneal fluid, obtained by puncture of Douglas pouch in 52 patients with tubal ectopic pregnancy. hCG level was determined in the cul-de-sac fluid and in the maternal serum for comparison. Tubectomy (5.3%), history of abortion (9.5%), history of previous surgery (14.8%), previous cesarean section (8%) and pelvic infamatorry disease (15.9 %) were the important risk factors for ectopic pregnancy in our cases. In 51 of 52 patients with tubal pregnancy, the cul-de-sac hCG vaule and the serum hCG value ratio was >1. It is concluded that the ratio of hCG in cul-de -sac and serum can be used for the verification of tubal ectopic pregnancy in addition to other diagnostic methods. This may help rapid confirmation of the diagnosis of ectopic pregnancy.

  15. 75 FR 26196 - Publication of OIG Updated Special Fraud Alert on Telemarketing by Durable Medical Equipment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... Special Fraud Alert on Telemarketing by Durable Medical Equipment Suppliers AGENCY: Office of Inspector... Special Fraud Alert. Specifically, the Updated Special Fraud Alert addressed the statutory provision...) 205-0007. SUPPLEMENTARY INFORMATION: In our publication of the OIG Updated Special Fraud Alert on...

  16. Parts, Materials, and Processes Experience Summary. Volume 1; [Catalog of ALERT and Other Information on Basic Design, Reliability, Quality and Applications Programs

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The ALERT program, a system for communicating common problems with parts, materials, and processes, is condensed and catalogued. Expanded information on selected topics is provided by relating the problem area (failure) to the cause, the investigations and findings, the suggestions for avoidance (inspections, screening tests, proper part applications), and failure analysis procedures. The basic objective of ALERT is the avoidance of the recurrence of parts, materials, and processed problems, thus improving the reliability of equipment produced for and used by the government.

  17. Good "Geofences" Make Good Neighbors in Age of Mobile Alerts

    ERIC Educational Resources Information Center

    Bender, Jim

    2013-01-01

    For every institution of higher education, the safety and protection of its campus community is of primary importance. Recent events have shown an increase in campus crime, assaults and even a tragic loss of life. Apps such as Ping4alerts! allow campuses to send hyperlocal smartphone alerts related to public safety, school closings, local events,…

  18. Earthquake Early Warning ShakeAlert System: Testing and certification platform

    USGS Publications Warehouse

    Cochran, Elizabeth S.; Kohler, Monica D.; Given, Douglas; Guiwits, Stephen; Andrews, Jennifer; Meier, Men-Andrin; Ahmad, Mohammad; Henson, Ivan; Hartog, Renate; Smith, Deborah

    2017-01-01

    Earthquake early warning systems provide warnings to end users of incoming moderate to strong ground shaking from earthquakes. An earthquake early warning system, ShakeAlert, is providing alerts to beta end users in the western United States, specifically California, Oregon, and Washington. An essential aspect of the earthquake early warning system is the development of a framework to test modifications to code to ensure functionality and assess performance. In 2016, a Testing and Certification Platform (TCP) was included in the development of the Production Prototype version of ShakeAlert. The purpose of the TCP is to evaluate the robustness of candidate code that is proposed for deployment on ShakeAlert Production Prototype servers. TCP consists of two main components: a real‐time in situ test that replicates the real‐time production system and an offline playback system to replay test suites. The real‐time tests of system performance assess code optimization and stability. The offline tests comprise a stress test of candidate code to assess if the code is production ready. The test suite includes over 120 events including local, regional, and teleseismic historic earthquakes, recentering and calibration events, and other anomalous and potentially problematic signals. Two assessments of alert performance are conducted. First, point‐source assessments are undertaken to compare magnitude, epicentral location, and origin time with the Advanced National Seismic System Comprehensive Catalog, as well as to evaluate alert latency. Second, we describe assessment of the quality of ground‐motion predictions at end‐user sites by comparing predicted shaking intensities to ShakeMaps for historic events and implement a threshold‐based approach that assesses how often end users initiate the appropriate action, based on their ground‐shaking threshold. TCP has been developed to be a convenient streamlined procedure for objectively testing algorithms, and it has

  19. Disrupted Structural and Functional Networks and Their Correlation with Alertness in Right Temporal Lobe Epilepsy: A Graph Theory Study.

    PubMed

    Jiang, Wenyu; Li, Jianping; Chen, Xuemei; Ye, Wei; Zheng, Jinou

    2017-01-01

    Previous studies have shown that temporal lobe epilepsy (TLE) involves abnormal structural or functional connectivity in specific brain areas. However, limited comprehensive studies have been conducted on TLE associated changes in the topological organization of structural and functional networks. Additionally, epilepsy is associated with impairment in alertness, a fundamental component of attention. In this study, structural networks were constructed using diffusion tensor imaging tractography, and functional networks were obtained from resting-state functional MRI temporal series correlations in 20 right temporal lobe epilepsy (rTLE) patients and 19 healthy controls. Global network properties were computed by graph theoretical analysis, and correlations were assessed between global network properties and alertness. The results from these analyses showed that rTLE patients exhibit abnormal small-world attributes in structural and functional networks. Structural networks shifted toward more regular attributes, but functional networks trended toward more random attributes. After controlling for the influence of the disease duration, negative correlations were found between alertness, small-worldness, and the cluster coefficient. However, alertness did not correlate with either the characteristic path length or global efficiency in rTLE patients. Our findings show that disruptions of the topological construction of brain structural and functional networks as well as small-world property bias are associated with deficits in alertness in rTLE patients. These data suggest that reorganization of brain networks develops as a mechanism to compensate for altered structural and functional brain function during disease progression.

  20. Reader Survey for INSECT ALERTS.

    ERIC Educational Resources Information Center

    Miller, Mason E.; Sauer, Richard J.

    To determine what might be done to improve "Insect Alerts," which is a newsletter that carries "information on insect biology, abundance, activity and interpretation of control need," put out through the Michigan Cooperative Extension Service 26 weeks a year, a survey was conducted. A mail questionnaire was sent to all 120 county extension…