Sample records for safe low-cost method

  1. Commercial Motion Sensor Based Low-Cost and Convenient Interactive Treadmill.

    PubMed

    Kim, Jonghyun; Gravunder, Andrew; Park, Hyung-Soon

    2015-09-17

    Interactive treadmills were developed to improve the simulation of overground walking when compared to conventional treadmills. However, currently available interactive treadmills are expensive and inconvenient, which limits their use. We propose a low-cost and convenient version of the interactive treadmill that does not require expensive equipment and a complicated setup. As a substitute for high-cost sensors, such as motion capture systems, a low-cost motion sensor was used to recognize the subject's intention for speed changing. Moreover, the sensor enables the subject to make a convenient and safe stop using gesture recognition. For further cost reduction, the novel interactive treadmill was based on an inexpensive treadmill platform and a novel high-level speed control scheme was applied to maximize performance for simulating overground walking. Pilot tests with ten healthy subjects were conducted and results demonstrated that the proposed treadmill achieves similar performance to a typical, costly, interactive treadmill that contains a motion capture system and an instrumented treadmill, while providing a convenient and safe method for stopping.

  2. Rock breaking methods to replace blasting

    NASA Astrophysics Data System (ADS)

    Zhou, Huisheng; Xie, Xinghua; Feng, Yuqing

    2018-03-01

    The method of breaking rock by blasting has a high efficiency and the cost is relatively low, but the associated vibration, flyrock, production of toxic gases since the 1970’s, the Western developed countries began to study the safety of breaking rock. This paper introduces different methods and their progress to safely break rock. Ideally, safe rock breaking would have little vibration, no fly stone, and no toxic gases, which can be widely used in municipal engineering, road excavation, high-risk mining, quarrying and complex environment.

  3. Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet

    NASA Technical Reports Server (NTRS)

    Baker, Paul; Repaci, Max; Sames, David

    1998-01-01

    Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.

  4. Vial OrganicTM-Organic Chemistry Labs for High School and Junior College

    NASA Astrophysics Data System (ADS)

    Russo, Thomas J.; Meszaros, Mark

    1999-01-01

    Vial Organic is the most economical, safe, and time-effective method of performing organic chemistry experiments. Activities are carried out in low-cost, sealed vials. Vial Organic is extremely safe because only micro quantities of reactants are used, reactants are contained in tightly sealed vials, and only water baths are used for temperature control. Vial Organic laboratory activities are easily performed within one 50-minute class period. When heat is required, a simple hot-water bath is prepared from a beaker of water and an inexpensive immersion heater. The low cost, ease of use, and relatively short time requirement will allow organic chemistry to be experienced by more students with less confusion and intimidation.

  5. The Effectiveness of Different Interventions to Promote Poison Prevention Behaviours in Households with Children: A Network Meta-Analysis

    PubMed Central

    Achana, Felix A.; Sutton, Alex J.; Kendrick, Denise; Wynn, Persephone; Young, Ben; Jones, David R.; Hubbard, Stephanie J.; Cooper, Nicola J.

    2015-01-01

    Background There is evidence from 2 previous meta-analyses that interventions to promote poison prevention behaviours are effective in increasing a range of poison prevention practices in households with children. The published meta-analyses compared any intervention against a “usual care or no intervention” which potentially limits the usefulness of the analysis to decision makers. We aim to use network meta-analysis to simultaneously evaluate the effectiveness of different interventions to increase prevalence of safe storage of i) Medicines only, ii) Other household products only, iii) Poisons (both medicines and non-medicines), iv) Poisonous plants; and v) Possession of poison control centre (PCC) telephone number in households with children. Methods Data on the effectiveness of poison prevention interventions was extracted from primary studies identified in 2 newly-undertaken systematic reviews. Effect estimates were pooled across studies using a random effects network meta-analysis model. Results 28 of the 47 primary studies identified were included in the analysis. Compared to usual care intervention, the intervention with education and low cost/free equipment elements was most effective in promoting safe storage of medicines (odds ratio 2.51, 95% credible interval 1.01 to 6.00) while interventions with education, low cost/free equipment, home safety inspection and fitting components were most effective in promoting safe storage of other household products (2.52, 1.12 to 7.13), safe storage of poisons (11.10, 1.60 to 141.50) and possession of PCC number (38.82, 2.19 to 687.10). No one intervention package was more effective than the others in promoting safe storage of poisonous plants. Conclusion The most effective interventions varied by poison prevention practice, but education alone was not the most effective intervention for any poison prevention practice. Commissioners and providers of poison prevention interventions should tailor the interventions they commission or provide to the poison prevention practices they wish to promote. Highlights Network meta-analysis is useful for comparing multiple injury-prevention interventions. More intensive poison prevention interventions were more effective than education alone. Education and low cost/free equipment was most effective in promoting safe storage of medicines. Education, low cost/free equipment, home safety inspection and fitting was most effective in promoting safe storage of household products and poisons. Education, low cost/free equipment and home inspection were most effective in promoting possession of a poison control centre number. None of the intervention packages was more effective than the others in promoting safe storage of poisonous plants. PMID:25894385

  6. Setting priorities for safe motherhood interventions in resource-scarce settings.

    PubMed

    Prata, Ndola; Sreenivas, Amita; Greig, Fiona; Walsh, Julia; Potts, Malcolm

    2010-01-01

    Guide policy-makers in prioritizing safe motherhood interventions. Three models (LOW, MED, HIGH) were constructed based on 34 sub-Saharan African countries to assess the relative cost-effectiveness of available safe motherhood interventions. Cost and effectiveness data were compiled and inserted into the WHO Mother Baby Package Costing Spreadsheet. For each model we assessed the percentage in maternal mortality reduction after implementing all interventions, and optimal combinations of interventions given restricted budgets of US$ 0.50, US$ 1.00, US$ 1.50 per capital maternal health expenditures respectively for LOW, MED, and HIGH models. The most cost-effective interventions were family planning and safe abortion (fpsa), antenatal care including misoprostol distribution for postpartum hemorrhage prevention at home deliveries (anc-miso), followed by sepsis treatment (sepsis) and facility-based postpartum hemorrhage management (pph). The combination of interventions that avert the greatest number of maternal deaths should be prioritized and expanded to cover the greatest number of women at risk. Those which save the most number of lives in each model are 'fpsa, anc-miso' and 'fpsa, sepsis, safe delivery' for LOW; 'fpsa, anc-miso' and 'fpsa, sepsis, safe delivery' for MED; and 'fpsa, anc-miso, sepsis, eclampsia treatment, safe delivery' for HIGH settings. Safe motherhood interventions save a significant number of newborn lives.

  7. Low-cost, solution processable carbon nanotube supercapacitors and their characterization

    NASA Astrophysics Data System (ADS)

    Lehtimäki, Suvi; Tuukkanen, Sampo; Pörhönen, Juho; Moilanen, Pasi; Virtanen, Jorma; Honkanen, Mari; Lupo, Donald

    2014-06-01

    We report ecological and low-cost carbon nanotube (CNT) supercapacitors fabricated using a simple, scalable solution processing method, where the use of a highly porous and electrically conductive active material eliminates the need for a current collector. Electrodes were fabricated on a poly(ethylene terephthalate) substrate from a printable multi-wall CNT ink, where the CNTs are solubilized in water using xylan as a dispersion agent. The dispersion method facilitates a very high concentration of CNTs in the ink. Supercapacitors were assembled using a paper separator and an aqueous NaCl electrolyte and the devices were characterized with a galvanostatic discharge method defined by an industrial standard. The capacitance of the 2 cm^2 devices was 6 mF/cm^2 (2.3 F/g) and equivalent series resistance 80 Ω . Low-cost supercapacitors fabricated from safe and environmentally friendly materials have potential applications as energy storage devices in ubiquitous and autonomous intelligence as well as in disposable low-end products.

  8. CuIn(S,Se)(2) thin films prepared from a novel thioacetic acid-based solution and their photovoltaic application.

    PubMed

    Xie, Yian; Liu, Yufeng; Wang, Yaoming; Zhu, Xiaolong; Li, Aimin; Zhang, Lei; Qin, Mingsheng; Lü, Xujie; Huang, Fuqiang

    2014-04-28

    Low-cost and high-yield preparation of CuInSe2 films is the bottleneck for promising CuInSe2-based thin film solar cells. Here, we developed a simple, safe and cost-effective method using thioacetic acid to fabricate the absorber films of CuIn(S,Se)2 (CISSe). Dissolution of Cu2O and In(OH)3 in thioacetic acid was attributed to the strong coordination ability of S. The adhesive precursor solution can be prepared without any heating, centrifugation and inert gas protection, superior to the previously reported methods. The precursor CISSe layer was easily deposited in air by spin coating to ensure low cost. Uniform and compact CISSe thin films with well-crystallized and pure-phased CISSe grains were obtained after one step annealing. The as-prepared CISSe thin films were successfully applied to solar cells and a energy conversion efficiency of 6.75% was achieved. This facile preparation provides a low-cost and easy method to fabricate Cu-based thin film solar cells.

  9. Two-Dimensional Wavelike Spinel Lithium Titanate for Fast Lithium Storage

    PubMed Central

    Liu, Jiehua; Wei, Xiangfeng; Liu, Xue-Wei

    2015-01-01

    Safe fast-charging lithium-ion batteries (LIBs) have huge potential market size on demand according to their shortened charging time for high-power devices. Zero-strain spinel Li4Ti5O12 is one of ideal candidates for safe high-power batteries owing to its good cycling performance, low cost and safety. However, the inherent insulating characteristic of LTO seriously limits its high-rate capability. In this work, we successfully synthesize novel wavelike spinel LTO nanosheets using a facile ‘co-hydrolysis’ method, which is superior to molten-salt approach and traditional solvothermal method in some respects. The unique 2D structures have single-crystal framework with shortened path for Li ion transport. As a result, the N-doped 2D wavelike LTO with 0.6 wt.% of ‘carbon joint’ not only exhibits exciting capacity of ~180 and ~150 mA h g−1 for fast lithium storage at high discharge/charge rates of 1.7 and 8.5 A g−1 (10C and 50C) respectively, but also shows excellent low-temperature performance at −20°C. In addition, the cost may be further decreased due to recycled functional reagents. This novel nanostructured 2D LTO anode material makes it possible to develop safe fast-charging high-power lithium ion batteries. PMID:25985465

  10. Establishing a safe, rapid, convenient and low-cost antiviral assay of interferon bioactivity based on recombinant VSV expressing GFP.

    PubMed

    Chen, Weiye; Wen, Zhiyuan; Zhang, Jialin; Li, Cuicui; Huang, Kehe; Bu, Zhigao

    2018-02-01

    The methods of the quantitative assay of the antiviral activity of interferons (IFNs) (type I, II or III) are very important during carrying out of the research of them, since they were found. Here a recombinant vesicular stomatitis virus expressing green fluorescent protein (GFP) (VSV/GFP) and MDBK cells were used to develop an antiviral assay (AVA) for IFNs. This method was carried out on a 96-well cell culture plate, and the half reduction of virus replication was quantified by assaying GFP. To quantify GFP, cell lysis buffer was directly added to the wells infected with VSV/GFP to lyse cells, the VSV/GFP was then inactivated, and relative fluorescence unit (RFU) of GFP was measured and used to calculate the antiviral activity. This method needed only one step instead of three steps in the staining method with naphthol blue black, medium with phenol red can be used, and it had good reproducibility. The GFP-containing samples could be stored at 4°C in a wet box for at least 1 week without affecting the assay results. In addition, the results obtained with this method were similar to those obtained with the staining method. In conclusion, a safe, rapid, convenient and low-cost AVA of IFN based on recombinant VSV/GFP was established. Copyright © 2017. Published by Elsevier B.V.

  11. Quantitative Determination of Citric and Ascorbic Acid in Powdered Drink Mixes

    ERIC Educational Resources Information Center

    Sigmann, Samuella B.; Wheeler, Dale E.

    2004-01-01

    A procedure by which the reactions are used to quantitatively determine the amount of total acid, the amount of total ascorbic acid and the amount of citric acid in a given sample of powdered drink mix, are described. A safe, reliable and low-cost quantitative method to analyze consumer product for acid content is provided.

  12. The Simulation of the Recharging Method Based on Solar Radiation for an Implantable Biosensor.

    PubMed

    Li, Yun; Song, Yong; Kong, Xianyue; Li, Maoyuan; Zhao, Yufei; Hao, Qun; Gao, Tianxin

    2016-09-10

    A method of recharging implantable biosensors based on solar radiation is proposed. Firstly, the models of the proposed method are developed. Secondly, the recharging processes based on solar radiation are simulated using Monte Carlo (MC) method and the energy distributions of sunlight within the different layers of human skin have been achieved and discussed. Finally, the simulation results are verified experimentally, which indicates that the proposed method will contribute to achieve a low-cost, convenient and safe method for recharging implantable biosensors.

  13. The Simulation of the Recharging Method Based on Solar Radiation for an Implantable Biosensor

    PubMed Central

    Li, Yun; Song, Yong; Kong, Xianyue; Li, Maoyuan; Zhao, Yufei; Hao, Qun; Gao, Tianxin

    2016-01-01

    A method of recharging implantable biosensors based on solar radiation is proposed. Firstly, the models of the proposed method are developed. Secondly, the recharging processes based on solar radiation are simulated using Monte Carlo (MC) method and the energy distributions of sunlight within the different layers of human skin have been achieved and discussed. Finally, the simulation results are verified experimentally, which indicates that the proposed method will contribute to achieve a low-cost, convenient and safe method for recharging implantable biosensors. PMID:27626422

  14. Monitoring Moving Queries inside a Safe Region

    PubMed Central

    Al-Khalidi, Haidar; Taniar, David; Alamri, Sultan

    2014-01-01

    With mobile moving range queries, there is a need to recalculate the relevant surrounding objects of interest whenever the query moves. Therefore, monitoring the moving query is very costly. The safe region is one method that has been proposed to minimise the communication and computation cost of continuously monitoring a moving range query. Inside the safe region the set of objects of interest to the query do not change; thus there is no need to update the query while it is inside its safe region. However, when the query leaves its safe region the mobile device has to reevaluate the query, necessitating communication with the server. Knowing when and where the mobile device will leave a safe region is widely known as a difficult problem. To solve this problem, we propose a novel method to monitor the position of the query over time using a linear function based on the direction of the query obtained by periodic monitoring of its position. Periodic monitoring ensures that the query is aware of its location all the time. This method reduces the costs associated with communications in client-server architecture. Computational results show that our method is successful in handling moving query patterns. PMID:24696652

  15. An Undergraduate Investigation into the 10-23 DNA Enzyme that Cleaves RNA: DNA Can Cut It in the Biochemistry Laboratory

    ERIC Educational Resources Information Center

    Flynn-Charlebois, Amber; Burns, Jamie; Chapelliquen, Stephanie; Sanmartino, Holly

    2011-01-01

    A low-cost biochemistry experiment is described that demonstrates current techniques in the use of catalytic DNA molecules and introduces a nonradioactive, nonfluorescent, inexpensive, fast, and safe method for monitoring these nucleic acid reactions. The laboratory involves the exploration of the 10-23 DNA enzyme as it cleaves a specific RNA…

  16. Learning to dislike safe water products: results from a randomized controlled trial of the effects of direct and peer experience on willingness to pay.

    PubMed

    Luoto, Jill; Mahmud, Minhaj; Albert, Jeff; Luby, Stephen; Najnin, Nusrat; Unicomb, Leanne; Levine, David I

    2012-06-05

    Low-cost point-of-use (POU) safe water products have the potential to reduce waterborne illness, but adoption by the global poor remains low. We performed an eight-month randomized trial of four low-cost household water treatment products in Dhaka, Bangladesh. Intervention households (n = 600) received repeated educational messages about the importance of drinking safe water along with consecutive two-month free trials with each of four POU products in random order. Households randomly assigned to the control group (n = 200) did not receive free products or repeated educational messages. Households' willingness to pay for these products was quite low on average (as measured by bids in an incentive-compatible real-money auction), although a modest share was willing to pay the actual or expected retail price for low-cost chlorine-based products. Furthermore, contrary to our hypotheses that both one's own personal experience and the influence of one's peers would increase consumers' willingness to pay, direct experience significantly decreased mean bids by 18-55% for three of the four products and had no discernible effect on the fourth. Neighbor experience also did not increase bids. Widespread dissemination of safe water products is unlikely until we better understand the preferences and aspirations of these at-risk populations.

  17. The effectiveness of different interventions to promote poison prevention behaviours in households with children: a network meta-analysis.

    PubMed

    Achana, Felix A; Sutton, Alex J; Kendrick, Denise; Wynn, Persephone; Young, Ben; Jones, David R; Hubbard, Stephanie J; Cooper, Nicola J

    2015-01-01

    There is evidence from 2 previous meta-analyses that interventions to promote poison prevention behaviours are effective in increasing a range of poison prevention practices in households with children. The published meta-analyses compared any intervention against a "usual care or no intervention" which potentially limits the usefulness of the analysis to decision makers. We aim to use network meta-analysis to simultaneously evaluate the effectiveness of different interventions to increase prevalence of safe storage of i) Medicines only, ii) Other household products only, iii) Poisons (both medicines and non-medicines), iv) Poisonous plants; and v) Possession of poison control centre (PCC) telephone number in households with children. Data on the effectiveness of poison prevention interventions was extracted from primary studies identified in 2 newly-undertaken systematic reviews. Effect estimates were pooled across studies using a random effects network meta-analysis model. 28 of the 47 primary studies identified were included in the analysis. Compared to usual care intervention, the intervention with education and low cost/free equipment elements was most effective in promoting safe storage of medicines (odds ratio 2.51, 95% credible interval 1.01 to 6.00) while interventions with education, low cost/free equipment, home safety inspection and fitting components were most effective in promoting safe storage of other household products (2.52, 1.12 to 7.13), safe storage of poisons (11.10, 1.60 to 141.50) and possession of PCC number (38.82, 2.19 to 687.10). No one intervention package was more effective than the others in promoting safe storage of poisonous plants. The most effective interventions varied by poison prevention practice, but education alone was not the most effective intervention for any poison prevention practice. Commissioners and providers of poison prevention interventions should tailor the interventions they commission or provide to the poison prevention practices they wish to promote. Network meta-analysis is useful for comparing multiple injury-prevention interventions. More intensive poison prevention interventions were more effective than education alone. Education and low cost/free equipment was most effective in promoting safe storage of medicines. Education, low cost/free equipment, home safety inspection and fitting was most effective in promoting safe storage of household products and poisons. Education, low cost/free equipment and home inspection were most effective in promoting possession of a poison control centre number. None of the intervention packages was more effective than the others in promoting safe storage of poisonous plants.

  18. Injury and Illness Costs in the Certified Safe Farm Study

    ERIC Educational Resources Information Center

    Donham, Kelley J.; Rautiainen, Risto H.; Lange, Jeffrey L.; Schneiders, Sara

    2007-01-01

    Context: The Certified Safe Farm (CSF) intervention program aims to reduce occupational injuries and illnesses, and promote wellness to reduce health care and related costs to farmers, insurers, and other stakeholders. Purpose: To evaluate the cost effectiveness of CSF. Methods: Farms (316) located in a 9-county area of northwestern Iowa were…

  19. An Automated, Gravity-driven CSF Drainage System Decreases Complications and Lowers Costs

    PubMed Central

    Lieberson, Robert E; Meyer, William; Trang, Tung

    2017-01-01

    Background: FlowSafeTM (BeckerSmith Medical, Irvine, CA, USA) is a novel, robotic, external lumbar drainage (ELD) system, which was designed to control cerebrospinal fluid (CSF) drainage, reduce complications, and decrease treatment costs. Methods: Forty-seven consecutive neurosurgical patients requiring ELD were treated using the FlowSafe system. Results: In 39 of 40 patients with traumatic and surgical dural openings, potential CSF leaks were avoided. In seven patients with suspected normal pressure hydrocephalus, post-infectious ventriculomegaly, or pseudotumor cerebrum, we were able to assess the likelihood of improvement with shunting. The system, therefore, produced what we considered to be the “desired result” in 46 of 47 patients (98%). Our one treatment failure (2%) involved a patient with unrecognized hydrocephalus who, following a Chiari repair with a dural patch graft, was drained for six days. A persistent CSF leak eventually required a reoperation. Two patients (4%) described low-pressure headaches during treatment. Both responded to temporarily suspending or reducing the drainage rate. We saw no complications. Required nursing interventions were minimal.  Conclusions: The FlowSafe system was safe and effective. In our experience, there were fewer complications compared to currently available ELD systems. The FlowSafe was well tolerated by our patients. The near elimination of nursing interventions should allow lumbar drainage to be delivered in less costly, non-intensive care unit settings. Larger trials will be needed. PMID:28331772

  20. Frugal Biotech Applications of Low-Temperature Plasma.

    PubMed

    Machala, Zdenko; Graves, David B

    2018-06-01

    Gas discharge low-temperature air plasma can be utilized for a variety of applications, including biomedical, at low cost. We term these applications 'frugal plasma' - an example of frugal innovation. We demonstrate how simple, robust, low-cost frugal plasma devices can be used to safely disinfect instruments, surfaces, and water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Safe and consistent method of spot-welding platinum thermocouple wires and foils for high temperature measurements.

    PubMed

    Orr, G; Roth, M

    2012-08-01

    A low-voltage (mV) electronically triggered spot welding system for fabricating fine thermocouples and thin sheets used in high-temperature characterization of materials' properties is suggested. The system is based on the capacitance discharge method with a timed trigger for obtaining reliable and consistent welds. In contrast to existing techniques based on employing high voltage DC supplies for charging the capacitor or supplies with positive and negative rails, this method uses a simple, standard dual power supply available at most of the physical laboratories or can be acquired at a low cost. In addition, an efficient and simple method of fabricating non-sticking electrodes that do not contaminate the weld area is suggested and implemented.

  2. New geothermal heat extraction process to deliver clean power generation

    ScienceCinema

    McGrail, Pete

    2017-12-27

    A new method for capturing significantly more heat from low-temperature geothermal resources holds promise for generating virtually pollution-free electrical energy. Scientists at the Department of Energys Pacific Northwest National Laboratory will determine if their innovative approach can safely and economically extract and convert heat from vast untapped geothermal resources. The goal is to enable power generation from low-temperature geothermal resources at an economical cost. In addition to being a clean energy source without any greenhouse gas emissions, geothermal is also a steady and dependable source of power.

  3. Static electricity powered copper oxide nanowire microbicidal electroporation for water disinfection.

    PubMed

    Liu, Chong; Xie, Xing; Zhao, Wenting; Yao, Jie; Kong, Desheng; Boehm, Alexandria B; Cui, Yi

    2014-10-08

    Safe water scarcity occurs mostly in developing regions that also suffer from energy shortages and infrastructure deficiencies. Low-cost and energy-efficient water disinfection methods have the potential to make great impacts on people in these regions. At the present time, most water disinfection methods being promoted to households in developing countries are aqueous chemical-reaction-based or filtration-based. Incorporating nanomaterials into these existing disinfection methods could improve the performance; however, the high cost of material synthesis and recovery as well as fouling and slow treatment speed is still limiting their application. Here, we demonstrate a novel flow device that enables fast water disinfection using one-dimensional copper oxide nanowire (CuONW) assisted electroporation powered by static electricity. Electroporation relies on a strong electric field to break down microorganism membranes and only consumes a very small amount of energy. Static electricity as the power source can be generated by an individual person's motion in a facile and low-cost manner, which ensures its application anywhere in the world. The CuONWs used were synthesized through a scalable one-step air oxidation of low-cost copper mesh. With a single filtration, we achieved complete disinfection of bacteria and viruses in both raw tap and lake water with a high flow rate of 3000 L/(h·m(2)), equivalent to only 1 s of contact time. Copper leaching from the nanowire mesh was minimal.

  4. Hybrids - Best of both worlds. [liquid and solid propellants mated for safe reliable and low cost launch vehicles

    NASA Technical Reports Server (NTRS)

    Goldberg, Ben E.; Wiley, Dan R.

    1991-01-01

    An overview is presented of hybrid rocket propulsion systems whereby combining solids and liquids for launch vehicles could produce a safe, reliable, and low-cost product. The primary subsystems of a hybrid system consist of the oxidizer tank and feed system, an injector system, a solid fuel grain enclosed in a pressure vessel case, a mixing chamber, and a nozzle. The hybrid rocket has an inert grain, which reduces costs of development, transportation, manufacturing, and launch by avoiding many safety measures that must be taken when operating with solids. Other than their use in launch vehicles, hybrids are excellent for simulating the exhaust of solid rocket motors for material development.

  5. Acceptability and Use of Portable Drinking Water and Hand Washing Stations in Health Care Facilities and Their Impact on Patient Hygiene Practices, Western Kenya

    PubMed Central

    Otieno, Ronald; Odhiambo, Aloyce; Faith, Sitnah H.

    2015-01-01

    Many health care facilities (HCF) in developing countries lack access to reliable hand washing stations and safe drinking water. To address this problem, we installed portable, low-cost hand washing stations (HWS) and drinking water stations (DWS), and trained healthcare workers (HCW) on hand hygiene, safe drinking water, and patient education techniques at 200 rural HCFs lacking a reliable water supply in western Kenya. We performed a survey at baseline and a follow-up evaluation at 15 months to assess the impact of the intervention at a random sample of 40 HCFs and 391 households nearest to these HCFs. From baseline to follow-up, there was a statistically significant increase in the percentage of dispensaries with access to HWSs with soap (42% vs. 77%, p<0.01) and access to safe drinking water (6% vs. 55%, p<0.01). Female heads of household in the HCF catchment area exhibited statistically significant increases from baseline to follow-up in the ability to state target times for hand washing (10% vs. 35%, p<0.01), perform all four hand washing steps correctly (32% vs. 43%, p = 0.01), and report treatment of stored drinking water using any method (73% vs. 92%, p<0.01); the percentage of households with detectable free residual chlorine in stored drinking water did not change (6%, vs. 8%, p = 0.14). The installation of low-cost, low-maintenance, locally-available, portable hand washing and drinking water stations in rural HCFs without access to 24-hour piped water helped assure that health workers had a place to wash their hands and provide safe drinking water. This HCF intervention may have also contributed to the improvement of hand hygiene and reported safe drinking water behaviors among households nearest to HCFs. PMID:25961293

  6. Acceptability and use of portable drinking water and hand washing stations in health care facilities and their impact on patient hygiene practices, Western kenya.

    PubMed

    Bennett, Sarah D; Otieno, Ronald; Ayers, Tracy L; Odhiambo, Aloyce; Faith, Sitnah H; Quick, Robert

    2015-01-01

    Many health care facilities (HCF) in developing countries lack access to reliable hand washing stations and safe drinking water. To address this problem, we installed portable, low-cost hand washing stations (HWS) and drinking water stations (DWS), and trained healthcare workers (HCW) on hand hygiene, safe drinking water, and patient education techniques at 200 rural HCFs lacking a reliable water supply in western Kenya. We performed a survey at baseline and a follow-up evaluation at 15 months to assess the impact of the intervention at a random sample of 40 HCFs and 391 households nearest to these HCFs. From baseline to follow-up, there was a statistically significant increase in the percentage of dispensaries with access to HWSs with soap (42% vs. 77%, p<0.01) and access to safe drinking water (6% vs. 55%, p<0.01). Female heads of household in the HCF catchment area exhibited statistically significant increases from baseline to follow-up in the ability to state target times for hand washing (10% vs. 35%, p<0.01), perform all four hand washing steps correctly (32% vs. 43%, p = 0.01), and report treatment of stored drinking water using any method (73% vs. 92%, p<0.01); the percentage of households with detectable free residual chlorine in stored drinking water did not change (6%, vs. 8%, p = 0.14). The installation of low-cost, low-maintenance, locally-available, portable hand washing and drinking water stations in rural HCFs without access to 24-hour piped water helped assure that health workers had a place to wash their hands and provide safe drinking water. This HCF intervention may have also contributed to the improvement of hand hygiene and reported safe drinking water behaviors among households nearest to HCFs.

  7. A large-scale behavior change intervention to prevent Nipah transmission in Bangladesh: components and costs.

    PubMed

    Nahar, Nazmun; Asaduzzaman, Mohammad; Sultana, Rebeca; Garcia, Fernando; Paul, Repon C; Abedin, Jaynal; Sazzad, Hossain M S; Rahman, Mahmudur; Gurley, Emily S; Luby, Stephen P

    2017-06-26

    Nipah virus infection (NiV) is a bat-borne zoonosis transmitted to humans through consumption of NiV-contaminated raw date palm sap in Bangladesh. The objective of this analysis was to measure the cost of an NiV prevention intervention and estimate the cost of scaling it up to districts where spillover had been identified. We implemented a behavior change communication intervention in two districts, testing different approaches to reduce the risk of NiV transmission using community mobilization, interpersonal communication, posters and TV public service announcements on local television during the 2012-2014 sap harvesting seasons. In one district, we implemented a "no raw sap" approach recommending to stop drinking raw date palm sap. In another district, we implemented an "only safe sap" approach, recommending to stop drinking raw date palm sap but offering the option of drinking safe sap. This is sap covered with a barrier, locally called bana, to interrupt bats' access during collection. We conducted surveys among randomly selected respondents two months after the intervention to measure the proportion of people reached. We used an activity-based costing method to calculate the cost of the intervention. The implementation cost of the "no raw sap" intervention was $30,000 and the "only safe sap" intervention was $55,000. The highest cost was conducting meetings and interpersonal communication efforts. The lowest cost was broadcasting the public service announcements on local TV channels. To scale up a similar intervention in 30 districts where NiV spillover has occurred, would cost between $2.6 and $3.5 million for one season. Placing the posters would cost $96,000 and only broadcasting the public service announcement through local channels in 30 districts would cost $26,000. Broadcasting a TV public service announcement is a potential low cost option to advance NiV prevention. It could be supplemented with posters and targeted interpersonal communication, in districts with a high risk of NiV spillover.

  8. Quantification, dissipation behavior and risk assessment of ethion in green pea by gas chromatography-electron capture detector.

    PubMed

    Jan, Ishrat; Dar, Alamgir A; Mubashir, Sofi; Alam Wani, Ashraf; Mukhtar, Malik; Sofi, Khurshid A; Dar, Irshad H; Sofi, Javid A

    2018-05-01

    Residue investigation was carried out to scrutinize the persistence, dissipation behavior, half-life, and risk assessment of ethion on green pea fruit by spraying ethion at the fruiting stage followed by another application at 10 day intervals. The samples were extracted by using a quick, easy, low-cost, effective, rugged, and safe method, and the residues of ethion were analyzed by gas chromatography with electron capture detection. Here we report a novel, accurate, and cost-effective gas chromatography method for the determination of average deposits of ethion on green pea. The initial deposits were found to be 4.65 mg/kg following the application of insecticide. Residues of ethion reached below the detection limit of 0.10 mg/kg after 25 days at recommended dosage. The half-life of ethion was found to be 4.62 days. For risk assessment studies, the 25th day will be safe for consumers for the consumption of green peas. The developed method is simple, sensitive, selective, and repeatable and can be extended for ethion-based standardization of herbal formulations containing green pea and its use in pesticide industries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Cost-effectiveness analyses of self-harm strategies aimed at reducing the mortality of pesticide self-poisonings in Sri Lanka: a study protocol

    PubMed Central

    Madsen, Lizell Bustamante; Eddleston, Michael; Hansen, Kristian Schultz; Pearson, Melissa; Agampodi, Suneth; Jayamanne, Shaluka; Konradsen, Flemming

    2015-01-01

    Introduction An estimated 803 900 people worldwide died as a result of self-harm in 2012. The deliberate ingestion of pesticides has been identified as the method most frequently used to commit fatal self-harm globally. In Sri Lanka, it is estimated that up to 60% of all suicides are committed using this method. The aim of the present study is to assess the cost-effectiveness of an ongoing safe storage intervention currently taking place in a rural Sri Lankan district and to model the cost-effectiveness of implementing the safe storage intervention as well as four potential interventions (legislative, medical management, follow-up contact and mobile phone contact) on a national level. Methods and analysis Study design for all the strategies is a cost-effectiveness analysis. A governmental perspective is adopted. The time horizon for tracking the associated costs and health outcomes of the safe storage intervention on district level runs over 3 years. The time horizon is extended to 5 years when modelling a full national roll-out of the respective interventions. The discounting of costs and health outcomes are undertaken at the recommended real rate of 3%. Threshold analyses of the modelled strategies are employed to assess the strategies potential for cost-effectiveness, running scenarios with health outcome improvements ranging from 1% to 100%. Sensitivity analyses are also performed. The main outcome measures of the safe storage intervention are incremental cost-effectiveness ratios. Ethics and dissemination Ethical approval was granted for the safe storage project from the University of Peradeniya, Sri Lanka, in March of 2008. An amendment for the present study was granted from Rajarata University of Sri Lanka in November of 2013. Findings will be disseminated to public and private stakeholders in local and national government in Sri Lanka as well as the wider academic audience through peer-reviewed publications and international conferences. Trial registration number The safe storage cluster trial is registered with the Clinical Trials, ref: NCT1146496 (http://clinicaltrialsfeeds.org/clinical-trials/show/NCT1146496). PMID:25724984

  10. Machine cost analysis using the traditional machine-rate method and ChargeOut!

    Treesearch

    E. M. (Ted) Bilek

    2009-01-01

    Forestry operations require ever more use of expensive capital equipment. Mechanization is frequently necessary to perform cost-effective and safe operations. Increased capital should mean more sophisticated capital costing methodologies. However the machine rate method, which is the costing methodology most frequently used, dates back to 1942. CHARGEOUT!, a recently...

  11. A new service model for the treatment of severe anorexia nervosa in the community: the Anorexia Nervosa Intensive Treatment Team

    PubMed Central

    Munro, Calum; Thomson, Victoria; Corr, Jean; Randell, Louise; Davies, Jennie E.; Gittoes, Claire; Honeyman, Vicky; Freeman, Chris P.

    2014-01-01

    Aims and method A community intensive treatment service for severe anorexia nervosa is described. The service is multidisciplinary but driven by a focus on psychological formulation. Psychological and dietetic interventions are grounded in a process of active risk management. Evaluations of safety, cost and acceptability of the service are described. Results Patients are highly satisfied with their care. A relatively low mortality rate for such a high-risk population was observed. In-patient bed use and costs were substantially reduced. Clinical implications There is a case for greater use of intensive community care for patients with severe anorexia nervosa, as it can be acceptable to patients, relatively safe and cost less than admission. PMID:25285220

  12. Costs of postabortion care in public sector health facilities in Malawi: a cross-sectional survey.

    PubMed

    Benson, Janie; Gebreselassie, Hailemichael; Mañibo, Maribel Amor; Raisanen, Keris; Johnston, Heidi Bart; Mhango, Chisale; Levandowski, Brooke A

    2015-12-17

    Health systems could obtain substantial cost savings by providing safe abortion care rather than providing expensive treatment for complications of unsafely performed abortions. This study estimates current health system costs of treating unsafe abortion complications and compares these findings with newly-projected costs for providing safe abortion in Malawi. We conducted in-depth surveys of medications, supplies, and time spent by clinical personnel dedicated to postabortion care (PAC) for three treatment categories (simple, severe non-surgical, and severe surgical complications) and three uterine evacuation (UE) procedure types (manual vacuum aspiration (MVA), dilation and curettage (D&C) and misoprostol-alone) at 15 purposively-selected public health facilities. Per-case treatment costs were calculated and applied to national, annual PAC caseload data. The median cost per D&C case ($63) was 29% higher than MVA treatment ($49). Costs to treat severe non-surgical complications ($63) were almost five times higher than those of a simple PAC case ($13). Severe surgical complications were especially costly to treat at $128. PAC treatment in public facilities cost an estimated $314,000 annually. Transition to safe, legal abortion would yield an estimated cost reduction of 20%-30%. The method of UE and severity of complications have a large impact on overall costs. With a liberalized abortion law and implementation of induced abortion services with WHO-recommended UE methods, current PAC costs to the health system could markedly decrease.

  13. Enhanced ultrasound for advanced diagnostics, ultrasound tomography for volume limb imaging and prosthetic fitting

    NASA Astrophysics Data System (ADS)

    Anthony, Brian W.

    2016-04-01

    Ultrasound imaging methods hold the potential to deliver low-cost, high-resolution, operator-independent and nonionizing imaging systems - such systems couple appropriate algorithms with imaging devices and techniques. The increasing demands on general practitioners motivate us to develop more usable and productive diagnostic imaging equipment. Ultrasound, specifically freehand ultrasound, is a low cost and safe medical imaging technique. It doesn't expose a patient to ionizing radiation. Its safety and versatility make it very well suited for the increasing demands on general practitioners, or for providing improved medical care in rural regions or the developing world. However it typically suffers from sonographer variability; we will discuss techniques to address user variability. We also discuss our work to combine cylindrical scanning systems with state of the art inversion algorithms to deliver ultrasound systems for imaging and quantifying limbs in 3-D in vivo. Such systems have the potential to track the progression of limb health at a low cost and without radiation exposure, as well as, improve prosthetic socket fitting. Current methods of prosthetic socket fabrication remain subjective and ineffective at creating an interface to the human body that is both comfortable and functional. Though there has been recent success using methods like magnetic resonance imaging and biomechanical modeling, a low-cost, streamlined, and quantitative process for prosthetic cup design and fabrication has not been fully demonstrated. Medical ultrasonography may inform the design process of prosthetic sockets in a more objective manner. This keynote talk presents the results of progress in this area.

  14. Assessment of bio-safety of low-cost polyurethane urologic stents used in developing countries.

    PubMed

    Roy, Nobhojit; Waingankar, Santosh; Aggarwal, Gaurav

    2012-04-01

    Ureteral stents, despite their ubiquitous use, have not been evaluated for their safety and strength after removal from the patient. While literature is available from the industry with regards to manufacturing and specifications of stents, what happens to a stent after it is inserted into the body, still needs to be explored. We conducted a methodical study of 153 consecutive patients with urological problems who were stented with inexpensive polyurethane stents. Once removed from the patients, the stents were analyzed for breakload, tensile strength, elongation, pH, decomposition temperature, residue as well as diameter change. There was no significant change in the physical and mechanical properties of the stent after clinical use and the variance was within the acceptable range of biomaterials. There was minimal leaching of material and color change in all stents. The cheap polyurethane stents were found to be safe for use in patients, for the short time periods of in situ stenting. The degradation of physical and chemical properties of the stent was not significant. Thus it can be safely said that the stents currently in widespread use are cost-effective and physically safe for short spans of time.

  15. Inexpensive and Safe DNA Gel Electrophoresis Using Household Materials

    ERIC Educational Resources Information Center

    Ens, S.; Olson, A. B.; Dudley, C.; Ross, N. D., III; Siddiqi, A. A.; Umoh, K. M.; Schneegurt, M. A.

    2012-01-01

    Gel electrophoresis is the single most important molecular biology technique and it is central to life sciences research, but it is often too expensive for the secondary science classroom or homeschoolers. A simple safe low-cost procedure is described here that uses household materials to construct and run DNA gel electrophoresis. Plastic…

  16. Quick, easy, cheap, effective, rugged, and safe sample preparation approach for pesticide residue analysis using traditional detectors in chromatography: A review.

    PubMed

    Rahman, Md Musfiqur; Abd El-Aty, A M; Kim, Sung-Woo; Shin, Sung Chul; Shin, Ho-Chul; Shim, Jae-Han

    2017-01-01

    In pesticide residue analysis, relatively low-sensitivity traditional detectors, such as UV, diode array, electron-capture, flame photometric, and nitrogen-phosphorus detectors, have been used following classical sample preparation (liquid-liquid extraction and open glass column cleanup); however, the extraction method is laborious, time-consuming, and requires large volumes of toxic organic solvents. A quick, easy, cheap, effective, rugged, and safe method was introduced in 2003 and coupled with selective and sensitive mass detectors to overcome the aforementioned drawbacks. Compared to traditional detectors, mass spectrometers are still far more expensive and not available in most modestly equipped laboratories, owing to maintenance and cost-related issues. Even available, traditional detectors are still being used for analysis of residues in agricultural commodities. It is widely known that the quick, easy, cheap, effective, rugged, and safe method is incompatible with conventional detectors owing to matrix complexity and low sensitivity. Therefore, modifications using column/cartridge-based solid-phase extraction instead of dispersive solid-phase extraction for cleanup have been applied in most cases to compensate and enable the adaptation of the extraction method to conventional detectors. In gas chromatography, the matrix enhancement effect of some analytes has been observed, which lowers the limit of detection and, therefore, enables gas chromatography to be compatible with the quick, easy, cheap, effective, rugged, and safe extraction method. For liquid chromatography with a UV detector, a combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction was found to reduce the matrix interference and increase the sensitivity. A suitable double-layer column/cartridge-based solid-phase extraction might be the perfect solution, instead of a time-consuming combination of column/cartridge-based solid-phase extraction and dispersive solid-phase extraction. Therefore, replacing dispersive solid-phase extraction with column/cartridge-based solid-phase extraction in the cleanup step can make the quick, easy, cheap, effective, rugged, and safe extraction method compatible with traditional detectors for more sensitive, effective, and green analysis. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Ultrahigh vacuum and low-temperature cleaning of oxide surfaces using a low-concentration ozone beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pratt, A.; Department of Physics, University of York, Heslington, York YO10 5DD; Graziosi, P.

    We present a novel method of delivering a low-concentration (<15%) ozone beam to an ultra-high vacuum environment for the purpose of cleaning and dosing experimental samples through oxidation processing. The system described is safe, low-cost, and practical and overcomes the limitations of ozone transport in the molecular flow environment of high or ultrahigh vacuum whilst circumventing the use of pure ozone gas which is potentially highly explosive. The effectiveness of this method in removing surface contamination is demonstrated through comparison of high-temperature annealing of a simple oxide (MgO) in ozone and oxygen environments as monitored using quadrupole mass spectroscopy andmore » Auger electron spectroscopy. Additionally, we demonstrate the potential of ozone for obtaining clean complex oxide surfaces without the need for high-temperature annealing which may significantly alter surface structure.« less

  18. The individual level cost of pregnancy termination in Zambia: a comparison of safe and unsafe abortion.

    PubMed

    Leone, Tiziana; Coast, Ernestina; Parmar, Divya; Vwalika, Bellington

    2016-09-01

    Zambia has one of the most liberal abortion laws in sub-Saharan Africa. However, rates of unsafe abortion remain high with negative health and economic consequences. Little is known about the economic burden on women of abortion care-seeking in low income countries. The majority of studies focus on direct costs (e.g. hospital fees). This article estimates the individual-level economic burden of safe and unsafe abortion care-seeking in Zambia, incorporating all indirect and direct costs. It uses data collected in 2013 from a tertiary hospital in Lusaka, (n = 112) with women who had an abortion. Three treatment routes are identified: (1) safe abortion at the hospital, (2) unsafe clandestine medical abortion initiated elsewhere with post-abortion care at the hospital and (3) unsafe abortion initiated elsewhere with post-abortion care at the hospital. Based on these three typologies, we use descriptive analysis and linear regression to estimate the costs for women of seeking safe and unsafe abortion and to establish whether the burden of abortion care-seeking costs is equally distributed across the sample. Around 39% of women had an unsafe abortion, incurring substantial economic costs before seeking post-abortion care. Adolescents and poorer women are more likely to use unsafe abortion. Unsafe abortion requiring post-abortion care costs women 27% more than a safe abortion. When accounting for uncertainty this figure increases dramatically. For safe and unsafe abortions, unofficial provider payments represent a major cost to women.This study demonstrates that despite a liberal legislation, Zambia still needs better dissemination of the law to women and providers and resources to ensure abortion service access. The policy implications of this study include: the role of pharmacists and mid-level providers in the provision of medical abortion services; increased access to contraception, especially for adolescents; and elimination of demands for unofficial provider payments. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Doing more for less: identifying opportunities to expand public sector access to safe abortion in South Africa through budget impact analysis.

    PubMed

    Lince-Deroche, Naomi; Harries, Jane; Constant, Deborah; Morroni, Chelsea; Pleaner, Melanie; Fetters, Tamara; Grossman, Daniel; Blanchard, Kelly; Sinanovic, Edina

    2018-02-01

    To estimate the costs of public-sector abortion provision in South Africa and to explore the potential for expanding access at reduced cost by changing the mix of technologies used. We conducted a budget impact analysis using public sector abortion statistics and published cost data. We estimated the total costs to the public health service over 10 years, starting in South Africa's financial year 2016/17, given four scenarios: (1) holding service provision constant, (2) expanding public sector provision, (3) changing the abortion technologies used (i.e. the method mix), and (4) expansion plus changing the method mix. The public sector performed an estimated 20% of the expected total number of abortions in 2016/17; 26% and 54% of all abortions were performed illegally or in the private sector respectively. Costs were lowest in scenarios where method mix shifting occurred. Holding the proportion of abortions performed in the public-sector constant, shifting to more cost-effective service provision (more first-trimester services with more medication abortion and using the combined regimen for medical induction in the second trimester) could result in savings of $28.1 million in the public health service over the 10-year period. Expanding public sector provision through elimination of unsafe abortions would require an additional $192.5 million. South Africa can provide more safe abortions for less money in the public sector through shifting the methods provided. More research is needed to understand whether the cost of expanding access could be offset by savings from averting costs of managing unsafe abortions. South Africa can provide more safe abortions for less money in the public sector through shifting to more first-trimester methods, including more medication abortion, and shifting to a combined mifepristone plus misoprostol regimen for second trimester medical induction. Expanding access in addition to method mix changes would require additional funds. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Method for making a low density polyethylene waste form for safe disposal of low level radioactive material

    DOEpatents

    Colombo, P.; Kalb, P.D.

    1984-06-05

    In the method of the invention low density polyethylene pellets are mixed in a predetermined ratio with radioactive particulate material, then the mixture is fed through a screw-type extruder that melts the low density polyethylene under a predetermined pressure and temperature to form a homogeneous matrix that is extruded and separated into solid monolithic waste forms. The solid waste forms are adapted to be safely handled, stored for a short time, and safely disposed of in approved depositories.

  1. The Program Cost of a Brief Video Intervention Shown in Sexually Transmitted Disease Clinic Waiting Rooms.

    PubMed

    Gift, Thomas L; OʼDonnell, Lydia N; Rietmeijer, Cornelis A; Malotte, Kevin C; Klausner, Jeffrey D; Margolis, Andrew D; Borkowf, Craig B; Kent, Charlotte K; Warner, Lee

    2016-01-01

    Patients in sexually transmitted disease (STD) clinic waiting rooms represent a potential audience for delivering health messages via video-based interventions. A controlled trial at 3 sites found that patients exposed to one intervention, Safe in the City, had a significantly lower incidence of STDs compared with patients in the control condition. An evaluation of the intervention's cost could help determine whether such interventions are programmatically viable. The cost of producing the Safe in the City intervention was estimated using study records, including logs, calendars, and contract invoices. Production costs were divided by the 1650 digital video kits initially fabricated to get an estimated cost per digital video. Clinic costs for showing the video in waiting rooms included staff time costs for equipment operation and hardware depreciation and were estimated for the 21-month study observation period retrospectively. The intervention cost an estimated $416,966 to develop, equaling $253 per digital video disk produced. Per-site costs to show the video intervention were estimated to be $2699 during the randomized trial. The cost of producing and implementing Safe in the City intervention suggests that similar interventions could potentially be produced and made available to end users at a price that would both cover production costs and be low enough that the end users could afford them.

  2. Intelligent navigation and accurate positioning of an assist robot in indoor environments

    NASA Astrophysics Data System (ADS)

    Hua, Bin; Rama, Endri; Capi, Genci; Jindai, Mitsuru; Tsuri, Yosuke

    2017-12-01

    Intact robot's navigation and accurate positioning in indoor environments are still challenging tasks. Especially in robot applications, assisting disabled and/or elderly people in museums/art gallery environments. In this paper, we present a human-like navigation method, where the neural networks control the wheelchair robot to reach the goal location safely, by imitating the supervisor's motions, and positioning in the intended location. In a museum similar environment, the mobile robot starts navigation from various positions, and uses a low-cost camera to track the target picture, and a laser range finder to make a safe navigation. Results show that the neural controller with the Conjugate Gradient Backpropagation training algorithm gives a robust response to guide the mobile robot accurately to the goal position.

  3. A high-voltage rechargeable magnesium-sodium hybrid battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yifei; An, Qinyou; Cheng, Yingwen

    2017-04-01

    Growing global demand of safe and low-cost energy storage technology triggers strong interests in novel battery concepts beyond state-of-art Li-ion batteries. Here we report a high-voltage rechargeable Mg–Na hybrid battery featuring dendrite-free deposition of Mg anode and Na-intercalation cathode as a low-cost and safe alternative to Li-ion batteries for large-scale energy storage. A prototype device using a Na3V2(PO4)3 cathode, a Mg anode, and a Mg–Na dual salt electrolyte exhibits the highest voltage (2.60 V vs. Mg) and best rate performance (86% capacity retention at 10C rate) among reported hybrid batteries. Synchrotron radiation-based X-ray absorption near edge structure (XANES), atomic-pair distributionmore » function (PDF), and high-resolution X-ray diffraction (HRXRD) studies reveal the chemical environment and structural change of Na3V2(PO4)3 cathode during the Na ion insertion/deinsertion process. XANES study shows a clear reversible shift of vanadium K-edge and HRXRD and PDF studies reveal a reversible two-phase transformation and V–O bond length change during cycling. The energy density of the hybrid cell could be further improved by developing electrolytes with a higher salt concentration and wider electrochemical window. This work represents a significant step forward for practical safe and low-cost hybrid batteries.« less

  4. A high-voltage rechargeable magnesium-sodium hybrid battery

    DOE PAGES

    Li, Yifei; An, Qinyou; Cheng, Yingwen; ...

    2017-02-13

    There is a growing global demand for safe and low-cost energy storage technology which triggers strong interests in novel battery concepts beyond state-of-art Li-ion batteries. We report a high-voltage rechargeable Mg–Na hybrid battery featuring dendrite-free deposition of Mg anode and Na-intercalation cathode as a low-cost and safe alternative to Li-ion batteries for large-scale energy storage. A prototype device using a Na 3V 2(PO 4) 3 cathode, a Mg anode, and a Mg–Na dual salt electrolyte exhibits the highest voltage (2.60 V vs. Mg) and best rate performance (86% capacity retention at 10 C rate) among reported hybrid batteries. Synchrotron radiation-basedmore » X-ray absorption near edge structure (XANES), atomic-pair distribution function (PDF), and high-resolution X-ray diffraction (HRXRD) studies reveal the chemical environment and structural change of Na 3V 2(PO 4) 3 cathode during the Na ion insertion/deinsertion process. XANES study shows a clear reversible shift of vanadium K-edge and HRXRD and PDF studies reveal a reversible two-phase transformation and V–O bond length change during cycling. The energy density of the hybrid cell could be further improved by developing electrolytes with a higher salt concentration and wider electrochemical window. Our work represents a significant step forward for practical safe and low-cost hybrid batteries.« less

  5. Factors Associated with the Hospitalization of Low-risk Patients with Community-acquired Pneumonia in a Cluster-Randomized Trial

    PubMed Central

    2006-01-01

    Medical evidence suggests that it is safe and less costly to treat low-risk patients with pneumonia in the outpatient setting. We analyzed the risk factors for hospitalization of low-risk patients defined by comparing 1,044 outpatients and 845 inpatients from 32 hospital emergency departments. Hospitalization was justified for one-third of inpatients, while one-fifth of inpatients had no identifiable risk factors for hospitalization. These findings suggest that while a sizeable proportion of patients defined as low risk have an appropriate indication for hospitalization, an even larger proportion of low-risk patients could safely be treated in the outpatient setting.

  6. Design of low-cost general purpose microcontroller based neuromuscular stimulator.

    PubMed

    Koçer, S; Rahmi Canal, M; Güler, I

    2000-04-01

    In this study, a general purpose, low-cost, programmable, portable and high performance stimulator is designed and implemented. For this purpose, a microcontroller is used in the design of the stimulator. The duty cycle and amplitude of the designed system can be controlled using a keyboard. The performance test of the system has shown that the results are reliable. The overall system can be used as the neuromuscular stimulator under safe conditions.

  7. A Low-Cost Simulation Model for R-Wave Synchronized Atrial Pacing in Pediatric Patients with Postoperative Junctional Ectopic Tachycardia

    PubMed Central

    Michel, Miriam; Egender, Friedemann; Heßling, Vera; Dähnert, Ingo; Gebauer, Roman

    2016-01-01

    Background Postoperative junctional ectopic tachycardia (JET) occurs frequently after pediatric cardiac surgery. R-wave synchronized atrial (AVT) pacing is used to re-establish atrioventricular synchrony. AVT pacing is complex, with technical pitfalls. We sought to establish and to test a low-cost simulation model suitable for training and analysis in AVT pacing. Methods A simulation model was developed based on a JET simulator, a simulation doll, a cardiac monitor, and a pacemaker. A computer program simulated electrocardiograms. Ten experienced pediatric cardiologists tested the model. Their performance was analyzed using a testing protocol with 10 working steps. Results Four testers found the simulation model realistic; 6 found it very realistic. Nine claimed that the trial had improved their skills. All testers considered the model useful in teaching AVT pacing. The simulation test identified 5 working steps in which major mistakes in performance test may impede safe and effective AVT pacing and thus permitted specific training. The components of the model (exclusive monitor and pacemaker) cost less than $50. Assembly and training-session expenses were trivial. Conclusions A realistic, low-cost simulation model of AVT pacing is described. The model is suitable for teaching and analyzing AVT pacing technique. PMID:26943363

  8. Aqueous Solution-Phase Selenized CuIn(S,Se)2 Thin Film Solar Cells Annealed under Inert Atmosphere.

    PubMed

    Oh, Yunjung; Yang, Wooseok; Kim, Jimin; Woo, Kyoohee; Moon, Jooho

    2015-10-14

    A nonvacuum solution-based approach can potentially be used to realize low cost, roll-to-roll fabrication of chalcopyrite CuIn(S,Se)2 (CISSe) thin film solar cells. However, most solution-based fabrication methods involve highly toxic solvents and inevitably require sulfurization and/or postselenization with hazardous H2S/H2Se gases. Herein, we introduce novel aqueous-based Cu-In-S and Se inks that contain an amine additive for producing a high-quality absorber layer. CISSe films were fabricated by simple deposition of Cu-In-S ink and Se ink followed by annealing under an inert atmosphere. Compositional and phase analyses confirmed that our simple aqueous ink-based method facilitated in-site selenization of the CIS layer. In addition, we investigated the molecular structures of our aqueous inks to determine how crystalline chalcopyrite absorber layers developed without sulfurization and/or postselenization. CISSe thin film solar cells annealed at 550 °C exhibited an efficiency of 4.55% under AM 1.5 illumination. The low-cost, nonvacuum method to deposit chalcopyrite absorber layers described here allows for safe and simple processing of thin film solar cells.

  9. Facile synthesis of graphene by pyrolysis of poly(methyl methacrylate) on nickel particles in the confined microzones

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, Ningning; Yang, Wei; Suzhou Key Laboratory of Urban Public Safety, Suzhou Institute of University of Science and Technology of China, Suzhou, Jiangsu, 215123

    2012-12-15

    Graphical abstract: Display Omitted Highlights: ► The GNWs with few defects were synthesized by pyrolyzing PMMA on nickel particles. ► PMMA as carbon source was easily prepared and safe to handle. ► Nickel microparticles were directly used as catalysts without any pre-treatment. ► The method can be used for the low cost and bulk production of graphene. -- Abstract: In this work, multi-layer graphene has been prepared by pyrolyzing poly(methyl methacrylate) (PMMA) on nickel microparticles in the confined microzones formed by organophilic montmorillonite (OMT). Gram-scale of product can be obtained per day by using this method. The obtained graphene wasmore » evaluated by scanning and transmission electron microscopy, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy and thermogravimetric analysis. Pyrolytic conditions such as the system composition of the composites, reaction temperature and the size of catalyst are important parameters affecting the morphology and yield of the final product. Based on the experimental observations and reported literatures, a possible formation process is discussed. The synthesis method of graphene is simple, low-cost, and scalable, which is promising for the application in many fields.« less

  10. Rfinity

    ScienceCinema

    Aaron R. Turner

    2017-12-09

    An innovation that offers a low-cost, plug-n-play option that enables virtually any wireless telecommunications device to safely store sensitive personal information and perform secure transactions. INL researchers include Steven McCown, Aaron Turner, Kur

  11. Rfinity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aaron R. Turner

    An innovation that offers a low-cost, plug-n-play option that enables virtually any wireless telecommunications device to safely store sensitive personal information and perform secure transactions. INL researchers include Steven McCown, Aaron Turner, Kur

  12. The advance of non-invasive detection methods in osteoarthritis

    NASA Astrophysics Data System (ADS)

    Dai, Jiao; Chen, Yanping

    2011-06-01

    Osteoarthritis (OA) is one of the most prevalent chronic diseases which badly affected the patients' living quality and economy. Detection and evaluation technology can provide basic information for early treatment. A variety of imaging methods in OA were reviewed, such as conventional X-ray, computed tomography (CT), ultrasound (US), magnetic resonance imaging (MRI) and near-infrared spectroscopy (NIRS). Among the existing imaging modalities, the spatial resolution of X-ray is extremely high; CT is a three-dimensional method, which has high density resolution; US as an evaluation method of knee OA discriminates lesions sensitively between normal cartilage and degenerative one; as a sensitive and nonionizing method, MRI is suitable for the detection of early OA, but the cost is too expensive for routine use; NIRS is a safe, low cost modality, and is also good at detecting early stage OA. In a word, each method has its own advantages, but NIRS is provided with broader application prospect, and it is likely to be used in clinical daily routine and become the golden standard for diagnostic detection.

  13. Cost and financial sustainability of a household-based water treatment and storage intervention in Zambia.

    PubMed

    Banerjee, Anyana; McFarland, Deborah A; Singh, Ritu; Quick, Robert

    2007-09-01

    Providing safe water to >1 billion people in need is a major challenge. To address this need, the Safe Water System (SWS) - household water treatment with dilute bleach, safe water storage, and behavior change - has been implemented in >20 countries. To assess the potential sustainability of the SWS, we analyzed costs in Zambia of "Clorin" brand product sold in bottles sufficient for a month of water treatment at a price of $0.09. We analyzed production, marketing, distribution, and overhead costs of Clorin before and after sales reached nationwide scale, and analyzed Clorin sales revenue. The average cost per bottle of Clorin production, marketing and distribution at start-up in 1999 was $1.88 but decreased by 82% to $0.33 in 2003, when >1.7 million bottles were sold. The financial loss per bottle decreased from $1.72 in 1999 to $0.24 in 2003. Net program costs in 2003 were $428,984, or only $0.04 per person-month of protection. A sensitivity analysis showed that if the bottle price increased to $0.18, the project would be self-sustaining at maximum capacity. This analysis demonstrated that efficiencies in the SWS supply chain can be achieved through social marketing. Even with a subsidy, overall program costs per beneficiary are low.

  14. Facile Access to Graphene Oxide from Ferro-Induced Oxidation

    NASA Astrophysics Data System (ADS)

    Yu, Chao; Wang, Cai-Feng; Chen, Su

    2016-01-01

    Methods allowing the oxidation of graphite to graphene oxide (GO) are vital important for the production of graphene from GO. This oxidation reaction has mainly relied on strong acid strategy for 174 years, which circumvents issues associated with toxicity of reagent and product, complex post-treatment, high cost and waste generation. Here, we report a green route for performing this oxidization reaction via a ferro-induced strategy, with use of water, potassium ferrate (Fe(VI)) and hydrogen peroxide (H2O2) as reagents, to produce about 65% yield of GO (vs. 40% for Hummers’ method, the most commonly used concentrated acid strategy) and non-toxic by-products. Moreover, GO produced from this new method shows equivalent performance to those reported previously. This H2SO4-free strategy makes it possible to process graphite into GO in a safe, low-cost, time-saving, energy-efficient and eco-friendly pathway, opening a promising avenue for the large-scale production of GO and GO-based materials.

  15. Facile Access to Graphene Oxide from Ferro-Induced Oxidation.

    PubMed

    Yu, Chao; Wang, Cai-Feng; Chen, Su

    2016-01-28

    Methods allowing the oxidation of graphite to graphene oxide (GO) are vital important for the production of graphene from GO. This oxidation reaction has mainly relied on strong acid strategy for 174 years, which circumvents issues associated with toxicity of reagent and product, complex post-treatment, high cost and waste generation. Here, we report a green route for performing this oxidization reaction via a ferro-induced strategy, with use of water, potassium ferrate (Fe(VI)) and hydrogen peroxide (H2O2) as reagents, to produce about 65% yield of GO (vs. 40% for Hummers' method, the most commonly used concentrated acid strategy) and non-toxic by-products. Moreover, GO produced from this new method shows equivalent performance to those reported previously. This H2SO4-free strategy makes it possible to process graphite into GO in a safe, low-cost, time-saving, energy-efficient and eco-friendly pathway, opening a promising avenue for the large-scale production of GO and GO-based materials.

  16. Facile Access to Graphene Oxide from Ferro-Induced Oxidation

    PubMed Central

    Yu, Chao; Wang, Cai-Feng; Chen, Su

    2016-01-01

    Methods allowing the oxidation of graphite to graphene oxide (GO) are vital important for the production of graphene from GO. This oxidation reaction has mainly relied on strong acid strategy for 174 years, which circumvents issues associated with toxicity of reagent and product, complex post-treatment, high cost and waste generation. Here, we report a green route for performing this oxidization reaction via a ferro-induced strategy, with use of water, potassium ferrate (Fe(VI)) and hydrogen peroxide (H2O2) as reagents, to produce about 65% yield of GO (vs. 40% for Hummers’ method, the most commonly used concentrated acid strategy) and non-toxic by-products. Moreover, GO produced from this new method shows equivalent performance to those reported previously. This H2SO4-free strategy makes it possible to process graphite into GO in a safe, low-cost, time-saving, energy-efficient and eco-friendly pathway, opening a promising avenue for the large-scale production of GO and GO-based materials. PMID:26818784

  17. Safe and private pedestrian detection by a low-cost fiber optic specklegram

    NASA Astrophysics Data System (ADS)

    Rodriguez-Cuevas, A.; Rodriguez-Cobo, L.; Lomer, M.; Lopez-Higuera, J. M.

    2017-04-01

    Surveillance is becoming more and more important in the recent years. In many cities, cameras have been set to look after parks, streets, roads, facilities and so on, however this fact is rising concerns about privacy. In this work, an alternative surveillance method which gather at once security and privacy has been propose and tested. Based on fiber optic specklegram technology; a system consisting of a fiber optic, a coherent light source and a photodetector has been placed under a carpet for detecting people walking over it and its accuracy, regarding measuring the steps, have been measured. Results suggest that using low exposed geometries along the carpet and basic processing methods, it is possible to detect with more than 95% of accuracy the number of steps done by the person walking over the carpet.

  18. A study to derive a clinical decision rule for triage of emergency department patients with chest pain: design and methodology

    PubMed Central

    Hess, Erik P; Wells, George A; Jaffe, Allan; Stiell, Ian G

    2008-01-01

    Background Chest pain is the second most common chief complaint in North American emergency departments. Data from the U.S. suggest that 2.1% of patients with acute myocardial infarction and 2.3% of patients with unstable angina are misdiagnosed, with slightly higher rates reported in a recent Canadian study (4.6% and 6.4%, respectively). Information obtained from the history, 12-lead ECG, and a single set of cardiac enzymes is unable to identify patients who are safe for early discharge with sufficient sensitivity. The 2007 ACC/AHA guidelines for UA/NSTEMI do not identify patients at low risk for adverse cardiac events who can be safely discharged without provocative testing. As a result large numbers of low risk patients are triaged to chest pain observation units and undergo provocative testing, at significant cost to the healthcare system. Clinical decision rules use clinical findings (history, physical exam, test results) to suggest a diagnostic or therapeutic course of action. Currently no methodologically robust clinical decision rule identifies patients safe for early discharge. Methods/design The goal of this study is to derive a clinical decision rule which will allow emergency physicians to accurately identify patients with chest pain who are safe for early discharge. The study will utilize a prospective cohort design. Standardized clinical variables will be collected on all patients at least 25 years of age complaining of chest pain prior to provocative testing. Variables strongly associated with the composite outcome acute myocardial infarction, revascularization, or death will be further analyzed with multivariable analysis to derive the clinical rule. Specific aims are to: i) apply standardized clinical assessments to patients with chest pain, incorporating results of early cardiac testing; ii) determine the inter-observer reliability of the clinical information; iii) determine the statistical association between the clinical findings and the composite outcome; and iv) use multivariable analysis to derive a highly sensitive clinical decision rule to guide triage decisions. Discussion The study will derive a highly sensitive clinical decision rule to identify low risk patients safe for early discharge. This will improve patient care, lower healthcare costs, and enhance flow in our busy and overcrowded emergency departments. PMID:18254973

  19. Biological sand filters: low-cost bioremediation technique for production of clean drinking water.

    PubMed

    Lea, Michael

    2014-05-01

    Approximately 1.1 billion people in rural and peri-urban communities of developing countries do not have access to safe drinking water. The mortality from diarrheal-related diseases amounts to ∼2.2 million people each year from the consumption of unsafe water. Most of them are children under 5 years of age--250 deaths an hour from microbiologically contaminated water. There is conclusive evidence that one low-cost household bioremediation intervention, use of biological sand filters, is capable of dramatically improving the microbiological quality of drinking water. This unit will describe this relatively new and proven bioremediation technology's ability to empower at-risk populations to use naturally occurring biological principles and readily available materials as a sustainable way to achieve the health benefits of safe drinking water. Copyright © 2014 John Wiley & Sons, Inc.

  20. Biological sand filters: low-cost bioremediation technique for production of clean drinking water.

    PubMed

    Lea, Michael

    2008-05-01

    Approximately 1.1 billion people in rural and peri-urban communities of developing countries do not have access to safe drinking water. The mortality from diarrheal-related diseases amounts to approximately 2.2 million people each year from the consumption of unsafe water. Most of them are children under 5 years of age-250 deaths an hour from microbiologically contaminated water. There is conclusive evidence that one low-cost household bioremediation intervention, biological sand filters, are capable of dramatically improving the microbiological quality of drinking water. This unit will describe this relatively new and proven bioremediation technology's ability to empower at-risk populations to use naturally occurring biology and readily available materials as a sustainable way to achieve the health benefits of safe drinking water. Copyright 2008 by John Wiley & Sons, Inc.

  1. Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico

    PubMed Central

    Seamans, Yancy; Harner-Jay, Claudia M

    2007-01-01

    Background Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy – simple ligation and excision (L and E) – appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. Methods The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). Results In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08 – $0.55. Conclusion Based on the results presented, more effective methods of vasectomy – including FI, thermal cautery, and thermal cautery combined with FI – are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods. PMID:17629921

  2. Stockpiling and Comprehensive Utilization of Red Mud Research Progress

    PubMed Central

    Liu, Dong-Yan; Wu, Chuan-Sheng

    2012-01-01

    With increasing production of red mud, the environmental problems caused by it are increasingly serious, and thus the integrated treatment of red mud is imminent. This article provides an overview of the composition and the basic characteristics of red mud. The research progress of safe stockpiling and comprehensive utilization of red mud is summarized. The safe stockpiling of red mud can be divided into two aspects: the design and safe operation of the stocking yard. The comprehensive utilization of red mud can be further divided into three aspects: the effective recycling of components, resource utilization and application in the field of environmental protection. This paper points out that the main focus of previous studies on red mud stockpiling is cost reproduction and land tenure. The recovery of resources from red mud has a high value-added, but low level industrialization. The use of red mud as a building material and filler material is the most effective way to reduce the stockpiling of red mud. Red mud used for environmental remediation materials is a new hotspot and worth promoting for its simple processing and low cost.

  3. Cost-Effectiveness Analysis of Fosfomycin for Treatment of Uncomplicated Urinary Tract Infections in Ontario

    PubMed Central

    Dahan, Sybil; Iliza, Ange Christelle; LeLorier, Jacques

    2017-01-01

    Background and Objective. Bacterial resistance to antibiotics traditionally used to treat uncomplicated urinary tract infections (uUTIs) is rising in Canada. We compared the cost-per-patient in Ontario of including fosfomycin (an antibiotic with a low resistance profile) as an option for first-line empirical treatment of uUTIs with current cost of treatment with sulfonamides, fluoroquinolones, and nitrofurantoin. Methods. A decision-tree model was used to perform a cost-minimization analysis. All possible outcomes of a uUTI caused by bacterial species treated with either sulfonamides, fluoroquinolones, nitrofurantoin, or fosfomycin were included. Results. In the base case analysis, the cost-per-patient for treating uUTI with fosfomycin was $105.12. This is similar to the cost-per-patient for each of the other currently reimbursed antibiotics (e.g., $96.19 for sulfonamides, $98.85 for fluoroquinolones, and $99.09 for nitrofurantoins). The weighted average cost-per-patient for treating uUTI was not substantially elevated with the inclusion of fosfomycin in the treatment landscape ($98.41 versus $98.29 with and without fosfomycin, resp.). The sensitivity analyses revealed that most (88.34%) of the potential variation in cost was associated with the probability of progressing to pyelonephritis and hospitalization for pyelonephritis. Conclusion. Fosfomycin in addition to being a safe and effective agent to treat uUTI has a low resistance profile, offers a single-dose treatment administration, and is similar in cost to other reimbursed antibiotics. PMID:28316632

  4. Biochar-based water treatment systems as a potential low-cost and sustainable technology for clean water provision.

    PubMed

    Gwenzi, Willis; Chaukura, Nhamo; Noubactep, Chicgoua; Mukome, Fungai N D

    2017-07-15

    Approximately 600 million people lack access to safe drinking water, hence achieving Sustainable Development Goal 6 (Ensure availability and sustainable management of water and sanitation for all by 2030) calls for rapid translation of recent research into practical and frugal solutions within the remaining 13 years. Biochars, with excellent capacity to remove several contaminants from aqueous solutions, constitute an untapped technology for drinking water treatment. Biochar water treatment has several potential merits compared to existing low-cost methods (i.e., sand filtration, boiling, solar disinfection, chlorination): (1) biochar is a low-cost and renewable adsorbent made using readily available biomaterials and skills, making it appropriate for low-income communities; (2) existing methods predominantly remove pathogens, but biochars remove chemical, biological and physical contaminants; (3) biochars maintain organoleptic properties of water, while existing methods generate carcinogenic by-products (e.g., chlorination) and/or increase concentrations of chemical contaminants (e.g., boiling). Biochars have co-benefits including provision of clean energy for household heating and cooking, and soil application of spent biochar improves soil quality and crop yields. Integrating biochar into the water and sanitation system transforms linear material flows into looped material cycles, consistent with terra preta sanitation. Lack of design information on biochar water treatment, and environmental and public health risks constrain the biochar technology. Seven hypotheses for future research are highlighted under three themes: (1) design and optimization of biochar water treatment; (2) ecotoxicology and human health risks associated with contaminant transfer along the biochar-soil-food-human pathway, and (3) life cycle analyses of carbon and energy footprints of biochar water treatment systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Rivaroxaban: An Affordable and Effective Alternative in Cancer-Related Thrombosis?

    PubMed Central

    Hoff, Paulo Marcelo Gehm; Braghiroli, Maria Ignez; Paterlini, Ana Carolina Carvalho Rocha; Souza, Karla Teixeira; Faria, Luiza Dib Batista Bugiato; Ferreira, Fernando Sergio Blumm; Machado, Karime Kalil; Fernandes, Gustavo dos Santos

    2017-01-01

    Background Venous thromboembolic events (VTEs) are common and potentially fatal complications in cancer patients, and they are responsible for the second most common cause of death. Low molecular weight heparin (LMWH) is the gold-standard treatment, but the costs involved limit its use, especially in developing countries. Recently, the oral anticoagulant rivaroxaban, which directly inhibits factor Xa, was approved for VTE treatment. Methods We conducted a retrospective analysis from January 2009 to February 2014 with patients who had cancer and VTE who were receiving rivaroxaban. We compared the efficacy, safety, and cost of rivaroxaban and low molecular weight heparin (LMWH) alone or followed by vitamin K antagonists. Results Forty-one patients were identified, with a median age of 62.5 years. The most frequent tumor histology was adenocarcinoma (78%), which was most often found in the colon (26.8%). Most participants had advanced disease and an implanted central venous catheter. Patients’ VTE risk-assessment scores were low (12.5%), intermediate (50%), and high (35.5%). Pulmonary thromboembolism was reported in 41.4% of patients, but inferior limb thrombosis was reported only in 14.6%; 43.9% of patients received enoxaparin before starting rivaroxaban. Rivaroxaban was used for a median time of 5.5 months. Nonmajor bleeding was reported in 12.2% of patients, and rethrombosis was reported in 12.2%. In our study, rivaroxaban was as safe and effective as enoxaparin/vitamin K antagonists (P = .54 and P = .25, respectively) or LMWH (P = .46 and P = .29, respectively). Conclusion Although our study was a retrospective analysis, our results suggest that in this cohort of oncologic patients, rivaroxaban was safe and effective. Its oral route and lower cost make it an attractive alternative to LMWH, improving management of patients with cancer in low-income countries. Additional studies are necessary to confirm our data. PMID:28717737

  6. Cost-outcome analysis in injury prevention and control: eighty-four recent estimates for the United States.

    PubMed

    Miller, T R; Levy, D T

    2000-06-01

    The objectives of this study were to review cost-outcome analyses in injury prevention and control and estimate associated benefit-cost ratios and cost per quality-adjusted life-year. Medline and Internet search, bibliographic review, and federal agency contacts identified published and unpublished studies from 1987 to 1998 for the United States. Studies of low quality and analyses of occupational, air, rail, and water transport safety programs were excluded. Selected results were recomputed to increase discount rate, benefit category, and benefit estimate comparability and to update injury incidence rates. More than half of the 84 injury prevention measures reviewed yielded net societal cost savings. Twelve measures had costs that exceeded benefits. Of 33 road safety measures analyzed, 19 yielded net cost savings. Of 34 violence prevention approaches studied, 19 yielded net cost savings, whereas 8 had costs that exceeded benefits. Interventions with the highest benefit-cost ratios included juvenile delinquent therapy programs, fire-safe cigarettes, federal road and traffic safety program funding, lane markers painted on roads, post-mounted reflectors on hazardous curves, safety belts in front seats, safety belt laws with primary enforcement, child safety seats, child bicycle helmets, enforcement of laws against serving alcohol to the intoxicated, substance abuse treatment, brief medical interventions with heavy drinkers, and a comprehensive safe communities program in a low-income neighborhood. Studies of cost-saving measures do not exist for several injury types. Injury prevention often can reduce medical costs and save lives. Wider implementation of proven measures is warranted.

  7. Cost-effectiveness of oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin in the emergency department.

    PubMed

    Rudis, Maria I; Touchette, Daniel R; Swadron, Stuart P; Chiu, Amy P; Orlinsky, Michael

    2004-03-01

    Oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin are all commonly used for loading phenytoin in the emergency department (ED). The cost-effectiveness of each was compared for patients presenting with seizures and subtherapeutic phenytoin concentrations. A simple decision tree was developed to determine the treatment costs associated with each of 3 loading techniques. We determined effectiveness by comparing adverse event rates and by calculating the time to safe ED discharge. Time to safe ED discharge was defined as the time at which therapeutic concentrations of phenytoin (>or=10 mg/L) were achieved with an absence of any adverse events that precluded discharge. The comparative cost-effectiveness of alternatives to oral phenytoin was determined by combining net costs and number of adverse events, expressed as cost per adverse events avoided. Cost-effectiveness was also determined by comparing the net costs of each loading technique required to achieve the time to safe ED discharge, expressed as cost per hour of ED time saved. The outcomes and costs were primarily derived from a prospective, randomized controlled trial, augmented by time-motion studies and alternate-cost sources. Costs included the cost of drugs, supplies, and personnel. Analyses were also performed in scenarios incorporating labor costs and savings from using a lower-urgency area of the ED. The mean number of adverse events per patient for oral phenytoin, intravenous phenytoin, and intravenous fosphenytoin was 1.06, 1.93, and 2.13, respectively. Mean time to safe ED discharge in the 3 groups was 6.4 hours, 1.7 hours, and 1.3 hours. Cost per patient was 2.83 dollars, 21.16 dollars, and 175.19 dollars, respectively, and did not differ substantially in the Labor and Triage (lower-urgency area of ED) scenarios. When the measure of effectiveness was adverse events, oral phenytoin dominated intravenous phenytoin and intravenous fosphenytoin, with a lower cost and number of adverse events. With time to safe ED discharge as the outcome measure, the incremental cost-effectiveness ratios were 3.90 dollars and 387.27 dollars per hour of ED time saved for oral phenytoin versus intravenous phenytoin and for intravenous fosphenytoin versus intravenous phenytoin, respectively. Oral phenytoin is the most cost-effective loading method in most settings. Intravenous phenytoin is preferred if one is willing to pay an additional 20.65 dollars to 44.25 dollars per patient and willing to have more adverse events for a quicker average time to safe ED discharge. It is unlikely that intravenous fosphenytoin is justifiable in any setting.

  8. Modelling cost-effectiveness of different vasectomy methods in India, Kenya, and Mexico.

    PubMed

    Seamans, Yancy; Harner-Jay, Claudia M

    2007-07-13

    Vasectomy is generally considered a safe and effective method of permanent contraception. The historical effectiveness of vasectomy has been questioned by recent research results indicating that the most commonly used method of vasectomy--simple ligation and excision (L and E)--appears to have a relatively high failure rate, with reported pregnancy rates as high as 4%. Updated methods such as fascial interposition (FI) and thermal cautery can lower the rate of failure but may require additional financial investments and may not be appropriate for low-resource clinics. In order to better compare the cost-effectiveness of these different vasectomy methods, we modelled the costs of different vasectomy methods using cost data collected in India, Kenya, and Mexico and effectiveness data from the latest published research. The costs associated with providing vasectomies were determined in each country through interviews with clinic staff. Costs collected were economic, direct, programme costs of fixed vasectomy services but did not include large capital expenses or general recurrent costs for the health care facility. Estimates of the time required to provide service were gained through interviews and training costs were based on the total costs of vasectomy training programmes in each country. Effectiveness data were obtained from recent published studies and comparative cost-effectiveness was determined using cost per couple years of protection (CYP). In each country, the labour to provide the vasectomy and follow-up services accounts for the greatest portion of the overall cost. Because each country almost exclusively used one vasectomy method at all of the clinics included in the study, we modelled costs based on the additional material, labour, and training costs required in each country. Using a model of a robust vasectomy program, more effective methods such as FI and thermal cautery reduce the cost per CYP of a vasectomy by $0.08-$0.55. Based on the results presented, more effective methods of vasectomy--including FI, thermal cautery, and thermal cautery combined with FI--are more cost-effective than L and E alone. Analysis shows that for a programme in which a minimum of 20 clients undergo vasectomies per month, the cost per CYP is reduced in all three countries by updated vasectomy methods.

  9. Cost-effectiveness of a new short-stay unit to "rule out" acute myocardial infarction in low risk patients.

    PubMed

    Gaspoz, J M; Lee, T H; Weinstein, M C; Cook, E F; Goldman, P; Komaroff, A L; Goldman, L

    1994-11-01

    This study attempted to determine the safety and costs of a new short-stay unit for low risk patients who may be admitted to a hospital to rule out myocardial infarction or ischemia. One strategy to reduce the costs of ruling out acute myocardial infarction in low risk patients is to develop alternatives to coronary care units. The short-term and 6-month clinical outcomes and costs for 592 patients admitted to a short-stay coronary observation unit at Brigham and Women's Hospital with a low (< or = 10%) probability of acute myocardial infarction were compared with those for 924 consecutive comparison patients who were eligible for the same unit but were admitted to other hospital settings or discharged home. Actual costs were calculated using detailed cost-accounting methods that incorporated nursing intensity weights. The rate of major complications, recurrent myocardial infarction or cardiac death during 6 months after the initial presentation of the 592 patients admitted to the coronary observation unit was similar to that of the 924 comparison patients before and after adjustment for clinical factors influencing triage and initial diagnoses (adjusted relative risk 0.86, 95% confidence interval 0.49 to 1.53). Their median total costs (25th, 75th percentile) at 6 months ($1,927; 1,455, 3,650) were significantly lower than for comparison patients admitted to the wards $4,712; 1,868, 11,187), to stepdown or intermediate care units ($4,031; 2,069, 9,169) or to the coronary care unit ($9,201; 3,171, 20,011) but were higher than for comparison patients discharged home from the emergency department ($403; 403,927) before and after the same adjustments (all adjusted p < 0.0001). These data suggest that the coronary observation unit may be a safe and cost-saving alternative to current triage strategies for patients with a low risk of acute myocardial infarction admitted from the emergency department. Its replication in other hospitals should be tested.

  10. Women's perceptions about abortion in their communities: perspectives from western Kenya.

    PubMed

    Marlow, Heather M; Wamugi, Sylvia; Yegon, Erick; Fetters, Tamara; Wanaswa, Leah; Msipa-Ndebele, Sinikiwe

    2014-05-01

    Unsafe abortion in Kenya is a leading cause of maternal morbidity and mortality. In October 2012, we sought to understand the methods married women aged 24-49 and young, unmarried women aged ≤ 20 used to induce abortion, the providers they utilized and the social, economic and cultural norms that influenced women's access to safe abortion services in Bungoma and Trans Nzoia counties in western Kenya. We conducted five focus groups with young women and five with married women in rural and urban communities in each county. We trained local facilitators to conduct the focus groups in Swahili or English. All focus groups were audiotaped, transcribed, translated, computerized, and coded for analysis. Abortion outside public health facilities was mentioned frequently. Because of the need for secrecy to avoid condemnation, uncertainty about the law, and perceived higher cost of safer abortion methods, women sought unsafe abortions from community midwives, drug sellers and/or untrained providers at lower cost. Many groups believed that abortion was safer at higher gestational ages, but that there was no such thing as a safe abortion method. Our aim was to inform the design of a community-based intervention on safe abortion for women. Barriers to seeking safe services such as high cost, perceived illegality, and fear of insults and abuse at public facilities among both age groups must be addressed. Copyright © 2014 Reproductive Health Matters. Published by Elsevier Ltd. All rights reserved.

  11. Addressing Challenges to the Shared Use of School Recreational Facilities

    ERIC Educational Resources Information Center

    Spengler, John O.; Connaughton, Daniel P.; Carroll, Michael S.

    2011-01-01

    The shared use of school recreational facilities holds the potential to offer activity opportunities for many people, especially those in low-income, minority, and under-resourced communities. School facilities are usually easily accessible and offer safe, free or low cost, and convenient recreation and sport opportunities. However, a number of…

  12. Synthesis of (E)-2-Styrylchromones and Flavones by Base-Catalyzed Cyclodehydration of the Appropriate β-Diketones Using Water as Solvent.

    PubMed

    Pinto, Joana; Silva, Vera L M; Silva, Ana M G; Silva, Artur M S

    2015-06-22

    A low cost, safe, clean and environmentally benign base-catalyzed cyclodehydration of appropriate β-diketones affording (E)-2-styrylchromones and flavones in good yields is disclosed. Water was used as solvent and the reactions were heated using classical and microwave heating methods, under open and closed vessel conditions. β-Diketones having electron-donating and withdrawing substituents were used to evaluate the reaction scope. The reaction products were isolated in high purity by simple filtration and recrystallization from ethanol, when using 800 mg of the starting diketone under classical reflux heating conditions.

  13. Measuring User Compliance and Cost Effectiveness of Safe Drinking Water Programs: A Cluster-Randomized Study of Household Ultraviolet Disinfection in Rural Mexico.

    PubMed

    Reygadas, Fermín; Gruber, Joshua S; Dreizler, Lindsay; Nelson, Kara L; Ray, Isha

    2018-03-01

    Low adoption and compliance levels for household water treatment and safe storage (HWTS) technologies have made it challenging for these systems to achieve measurable health benefits in the developing world. User compliance remains an inconsistently defined and poorly understood feature of HWTS programs. In this article, we develop a comprehensive approach to understanding HWTS compliance. First, our Safe Drinking Water Compliance Framework disaggregates and measures the components of compliance from initial adoption of the HWTS to exclusive consumption of treated water. We apply this framework to an ultraviolet (UV)-based safe water system in a cluster-randomized controlled trial in rural Mexico. Second, we evaluate a no-frills (or "Basic") variant of the program as well as an improved (or "Enhanced") variant, to test if subtle changes in the user interface of HWTS programs could improve compliance. Finally, we perform a full-cost analysis of both variants to assess their cost effectiveness (CE) in achieving compliance. We define "compliance" strictly as the habit of consuming safe water. We find that compliance was significantly higher in the groups where the UV program variants were rolled out than in the control groups. The Enhanced variant performed better immediately postintervention than the Basic, but compliance (and thus CE) degraded with time such that no effective difference remained between the two versions of the program.

  14. Feasibility of hospital-based blood banking: a Tanzanian case study.

    PubMed

    Jacobs, B; Mercer, A

    1999-12-01

    The demand for blood transfusion is high in sub-Saharan Africa because of the high prevalence of anaemia and pregnancy related complications, but the practice is estimated to account for 10% of HIV infections in some regions. The main response to this problem by the international donor community is to establish vertically implemented blood transfusion services producing suitable (safe) blood at a cost of US$25-40 per unit. However, the economic sustainability of such interventions is questionable and it is argued here that hospital-based blood transfusion services operating at a basic adequate level are sufficient for low-income African countries. The results of a project aimed at improving such services in Tanzania are presented. The main findings are: (1) the cost per suitable blood unit produced was US$12.4; (2) at an HIV test sensitivity of 93.5% during the study period, discounted financial benefits of the interventions exceeded costs by a factor of between 17.2 and 37.1; (3) the cost per undiscounted year of life saved by use of these interventions was US$2.7-2.8; and (4) safe blood transfusion practices can be assured at an annual cost of US$0.07 per capita. Recommendations are made to ensure safe blood transfusion practices at hospital-based blood banks in Tanzania.

  15. Terahertz Measurement of the Water Content Distribution in Wood Materials

    NASA Astrophysics Data System (ADS)

    Bensalem, M.; Sommier, A.; Mindeguia, J. C.; Batsale, J. C.; Pradere, C.

    2018-02-01

    Recently, THz waves have been shown to be an effective technique for investigating the water diffusion within porous media, such as biomaterial or insulation materials. This applicability is due to the sufficient resolution for such applications and the safe levels of radiation. This study aims to achieve contactless absolute water content measurements at a steady state case in semi-transparent solids (wood) using a transmittance THz wave range setup. First, a calibration method is developed to validate an analytical model based on the Beer-Lambert law, linking the absorption coefficient, the density of the solid, and its water content. Then, an estimation of the water content on a local scale in a transient-state case (drying) is performed. This study shows that THz waves are an effective contactless, safe, and low-cost technique for the measurement of water content in a porous medium, such as wood.

  16. Prediction of coronary artery disease in patients undergoing operations for mitral valve degeneration

    NASA Technical Reports Server (NTRS)

    Lin, S. S.; Lauer, M. S.; Asher, C. R.; Cosgrove, D. M.; Blackstone, E.; Thomas, J. D.; Garcia, M. J.

    2001-01-01

    OBJECTIVES: We sought to develop and validate a model that estimates the risk of obstructive coronary artery disease in patients undergoing operations for mitral valve degeneration and to demonstrate its potential clinical utility. METHODS: A total of 722 patients (67% men; age, 61 +/- 12 years) without a history of myocardial infarction, ischemic electrocardiographic changes, or angina who underwent routine coronary angiography before mitral valve prolapse operations between 1989 and 1996 were analyzed. A bootstrap-validated logistic regression model on the basis of clinical risk factors was developed to identify low-risk (< or =5%) patients. Obstructive coronary atherosclerosis was defined as 50% or more luminal narrowing in one or more major epicardial vessels, as determined by means of coronary angiography. RESULTS: One hundred thirty-nine (19%) patients had obstructive coronary atherosclerosis. Independent predictors of coronary artery disease include age, male sex, hypertension, diabetes mellitus,and hyperlipidemia. Two hundred twenty patients were designated as low risk according to the logistic model. Of these patients, only 3 (1.3%) had single-vessel disease, and none had multivessel disease. The model showed good discrimination, with an area under the receiver-operating characteristic curve of 0.84. Cost analysis indicated that application of this model could safely eliminate 30% of coronary angiograms, corresponding to cost savings of $430,000 per 1000 patients without missing any case of high-risk coronary artery disease. CONCLUSION: A model with standard clinical predictors can reliably estimate the prevalence of obstructive coronary atherosclerosis in patients undergoing mitral valve prolapse operations. This model can identify low-risk patients in whom routine preoperative angiography may be safely avoided.

  17. Patient-centered technological assessment and monitoring of depression for low-income patients.

    PubMed

    Wu, Shinyi; Vidyanti, Irene; Liu, Pai; Hawkins, Caitlin; Ramirez, Magaly; Guterman, Jeffrey; Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Ell, Kathleen

    2014-01-01

    Depression is a significant challenge for ambulatory care because it worsens health status and outcomes, increases health care utilizations and costs, and elevates suicide risk. An automatic telephonic assessment (ATA) system that links with tasks and alerts to providers may improve quality of depression care and increase provider productivity. We used ATA system in a trial to assess and monitor depressive symptoms of 444 safety-net primary care patients with diabetes. We assessed system properties, evaluated preliminary clinical outcomes, and estimated cost savings. The ATA system is feasible, reliable, valid, safe, and likely cost-effective for depression screening and monitoring for low-income primary care population.

  18. A novel method of personnel cooling in an operating theatre environment.

    PubMed

    Casha, Aaron R; Manché, Alexander; Camilleri, Liberato; Gauci, Marilyn; Grima, Joseph N; Borg, Michael A

    2014-10-01

    An optimized theatre environment, including personal temperature regulation, can help maintain concentration, extend work times and may improve surgical outcomes. However, devices, such as cooling vests, are bulky and may impair the surgeon's mobility. We describe the use of a low-cost, low-energy 'bladeless fan' as a personal cooling device. The safety profile of this device was investigated by testing air quality using 0.5- and 5-µm particle counts as well as airborne bacterial counts on an operating table simulating a wound in a thoracic operation in a busy theatre environment. Particle and bacterial counts were obtained with both an empty and full theatre, with and without the 'bladeless fan'. The use of the 'bladeless fan' within the operating theatre during the simulated operation led to a minor, not statistically significant, lowering of both the particle and bacterial counts. In conclusion, the 'bladeless fan' is a safe, effective, low-cost and low-energy consumption solution for personnel cooling in a theatre environment that maintains the clean room conditions of the operating theatre. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Acceptability of the rainwater harvesting system to the slum dwellers of Dhaka City.

    PubMed

    Islam, M M; Chou, F N-F; Kabir, M R

    2010-01-01

    Urban area like Dhaka City, in Bangladesh, has scarcity of safe drinking water which is one of the prominent basic needs for human kind. This study explored the acceptability of harvested rainwater in a densely populated city like Dhaka, using a simple and low cost technology. A total of 200 random people from four slums of water-scarce Dhaka City were surveyed to determine the dwellers' perception on rainwater and its acceptability as a source of drinking water. The questionnaire was aimed at finding the socio-economic condition and the information on family housing, sanitation, health, existing water supply condition, knowledge about rainwater, willingness to accept rainwater as a drinking source etc. A Yield before Spillage (YBS) model was developed to know the actual rainwater availability and storage conditions which were used to justify the effective tank size. Cost-benefit analysis and feasibility analysis were performed using the survey results and the research findings. The survey result and overall study found that the low cost rainwater harvesting technique was acceptable to the slum dwellers as only the potential alternative source of safe drinking water.

  20. Low Earth Orbit Raider (LER) winged air launch vehicle concept

    NASA Technical Reports Server (NTRS)

    Feaux, Karl; Jordan, William; Killough, Graham; Miller, Robert; Plunk, Vonn

    1989-01-01

    The need to launch small payloads into low earth orbit has increased dramatically during the past several years. The Low Earth orbit Raider (LER) is an answer to this need. The LER is an air-launched, winged vehicle designed to carry a 1500 pound payload into a 250 nautical mile orbit. The LER is launched from the back of a 747-100B at 35,000 feet and a Mach number of 0.8. Three staged solid propellant motors offer safe ground and flight handling, reliable operation, and decreased fabrication cost. The wing provides lift for 747 separation and during the first stage burn. Also, aerodynamic controls are provided to simplify first stage maneuvers. The air-launch concept offers many advantages to the consumer compared to conventional methods. Launching at 35,000 feet lowers atmospheric drag and other loads on the vehicle considerably. Since the 747 is a mobile launch pad, flexibility in orbit selection and launch time is unparalleled. Even polar orbits are accessible with a decreased payload. Most importantly, the LER launch service can come to the customer, satellites and experiments need not be transported to ground based launch facilities. The LER is designed to offer increased consumer freedom at a lower cost over existing launch systems. Simplistic design emphasizing reliability at low cost allows for the light payloads of the LER.

  1. Sterilization in the United States

    PubMed Central

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  2. Comparison and cost analysis of drinking water quality monitoring requirements versus practice in seven developing countries.

    PubMed

    Crocker, Jonny; Bartram, Jamie

    2014-07-18

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country's ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries.

  3. Magnetron sputtering source

    DOEpatents

    Makowiecki, Daniel M.; McKernan, Mark A.; Grabner, R. Fred; Ramsey, Philip B.

    1994-01-01

    A magnetron sputtering source for sputtering coating substrates includes a high thermal conductivity electrically insulating ceramic and magnetically attached sputter target which can eliminate vacuum sealing and direct fluid cooling of the cathode assembly. The magnetron sputtering source design results in greater compactness, improved operating characteristics, greater versatility, and low fabrication cost. The design easily retrofits most sputtering apparatuses and provides for safe, easy, and cost effective target replacement, installation, and removal.

  4. Safety evaluations under the proposed US Safe Cosmetics and Personal Care Products Act of 2013: animal use and cost estimates.

    PubMed

    Knight, Jean; Rovida, Costanca

    2014-01-01

    The proposed Safe Cosmetics and Personal Care Products Act of 2013 calls for a new evaluation program for cosmetic ingredients in the US, with the new assessments initially dependent on expanded animal testing. This paper considers possible testing scenarios under the proposed Act and estimates the number of test animals and cost under each scenario. It focuses on the impact for the first 10 years of testing, the period of greatest impact on animals and costs. The analysis suggests the first 10 years of testing under the Act could evaluate, at most, about 50% of ingredients used in cosmetics. Testing during this period would cost about $ 1.7-$ 9 billion and 1-11.5 million animals. By test year 10, alternative, high-throughput test methods under development are expected to be available, replacing animal testing and allowing rapid evaluation of all ingredients. Given the high cost in dollars and animal lives of the first 10 years for only about half of ingredients, a better choice may be to accelerate development of high-throughput methods. This would allow evaluation of 100% of cosmetic ingredients before year 10 at lower cost and without animal testing.

  5. Progress and future direction for the interim safe storage and disposal of Hanford high-level waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzer, J.E.; Wodrich, D.D.; Bacon, R.F.

    This paper describes the progress made at the largest environmental cleanup program in the United States. Substantial advances in methods to start interim safe storage of Hanford Site high-level wastes, waste characterization to support both safety- and disposal-related information needs, and proceeding with cost-effective disposal by the U.S. Department of Energy (DOE) and its Hanford Site contractors, have been realized. Challenges facing the Tank Waste Remediation System (TWRS) Program, which is charged with the dual and parallel missions of interim safe storage and disposal of the high-level tank waste stored at the Hanford Site, are described. In these times ofmore » budget austerity, implementing an ongoing program that combines technical excellence and cost effectiveness is the near-term challenge. The technical initiatives and progress described in this paper are made more cost effective by DOE`s focus on work force productivity improvement, reduction of overhead costs, and reduction, integration and simplification of DOE regulations and operations requirements to more closely model those used in the private sector.« less

  6. Multispectral digital holographic microscopy with applications in water quality assessment

    NASA Astrophysics Data System (ADS)

    Kazemzadeh, Farnoud; Jin, Chao; Yu, Mei; Amelard, Robert; Haider, Shahid; Saini, Simarjeet; Emelko, Monica; Clausi, David A.; Wong, Alexander

    2015-09-01

    Safe drinking water is essential for human health, yet over a billion people worldwide do not have access to safe drinking water. Due to the presence and accumulation of biological contaminants in natural waters (e.g., pathogens and neuro-, hepato-, and cytotoxins associated with algal blooms) remain a critical challenge in the provision of safe drinking water globally. It is not financially feasible and practical to monitor and quantify water quality frequently enough to identify the potential health risk due to contamination, especially in developing countries. We propose a low-cost, small-profile multispectral (MS) system based on Digital Holographic Microscopy (DHM) and investigate methods for rapidly capturing holographic data of natural water samples. We have developed a test-bed for an MSDHM instrument to produce and capture holographic data of the sample at different wavelengths in the visible and the near Infra-red spectral region, allowing for resolution improvement in the reconstructed images. Additionally, we have developed high-speed statistical signal processing and analysis techniques to facilitate rapid reconstruction and assessment of the MS holographic data being captured by the MSDHM instrument. The proposed system is used to examine cyanobacteria as well as Cryptosporidium parvum oocysts which remain important and difficult to treat microbiological contaminants that must be addressed for the provision of safe drinking water globally.

  7. Study of fail-safe abort system for an actively cooled hypersonic aircraft, volume 2

    NASA Technical Reports Server (NTRS)

    Peeples, M. E.; Herring, R. L.

    1976-01-01

    Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.

  8. The initial electrocardiogram during admission for myocardial infarction. Use as a predictor of clinical course and facility utilization.

    PubMed

    Stark, M E; Vacek, J L

    1987-05-01

    The first electrocardiogram obtained on presentation for suspected myocardial infarction was examined for its usefulness in predicting clinical course and facility use. We studied 221 patients consecutively admitted to a nonuniversity hospital coronary care unit. High-risk patients were identified if the electrocardiographic diagnoses included myocardial infarction, ischemia, left ventricular hypertrophy, left bundle-branch block, or paced rhythm. These 63 patients (29% of total) had significantly greater incidences of serious events, need for procedures, and death than low-risk patients whose initial electrocardiograms did not carry the above diagnoses. Patients with a low-risk initial electrocardiogram may not require the facilities of a coronary care unit and perhaps could be safely observed in an intermediate care area. However, many hospitals do not have an intermediate care facility available, and in those that do, daily costs may not be markedly different than for treatment in a coronary care unit. Whether these low-risk patients could be safely treated in general medicine beds, where potential cost savings would be much greater, is unknown.

  9. Vaccinating Health Care Workers Against Influenza: The Ethical and Legal Rationale for a Mandate

    PubMed Central

    Wu, Joel T.; Poland, Gregory A.; Jacobson, Robert M.; Koenig, Barbara A.; Tilburt, Jon C.

    2011-01-01

    Despite improvements in clinician education, symptom awareness, and respiratory precautions, influenza vaccination rates for health care workers have remained unacceptably low for more than three decades, adversely affecting patient safety. When public health is jeopardized, and a safe, low-cost, and effective method to achieve patient safety exists, health care organizations and public health authorities have a responsibility to take action and change the status quo. Mandatory influenza vaccination for health care workers is supported not only by scientific data but also by ethical principles and legal precedent. The recent influenza pandemic provides an opportunity for policymakers to reconsider the benefits of mandating influenza vaccination for health care workers, including building public trust, enhancing patient safety, and strengthening the health care workforce. PMID:21228284

  10. Vaccinating health care workers against influenza: the ethical and legal rationale for a mandate.

    PubMed

    Ottenberg, Abigale L; Wu, Joel T; Poland, Gregory A; Jacobson, Robert M; Koenig, Barbara A; Tilburt, Jon C

    2011-02-01

    Despite improvements in clinician education, symptom awareness, and respiratory precautions, influenza vaccination rates for health care workers have remained unacceptably low for more than three decades, adversely affecting patient safety. When public health is jeopardized, and a safe, low-cost, and effective method to achieve patient safety exists, health care organizations and public health authorities have a responsibility to take action and change the status quo. Mandatory influenza vaccination for health care workers is supported not only by scientific data but also by ethical principles and legal precedent. The recent influenza pandemic provides an opportunity for policymakers to reconsider the benefits of mandating influenza vaccination for health care workers, including building public trust, enhancing patient safety, and strengthening the health care workforce.

  11. Safe household water treatment and storage using ceramic drip filters: a randomised controlled trial in Bolivia.

    PubMed

    Clasen, T; Brown, J; Suntura, O; Collin, S

    2004-01-01

    A randomised controlled field trial was conducted to evaluate the effectiveness of ceramic drip filters to improve the microbiological quality of drinking water in a low-income community in rural Bolivia. In four rounds of water sampling over five months, 100% of the samples were free of thermotolerant (faecal) coliforms (TTC) compared to an arithmetic mean TTC count of 1517, 406, 167 and 245 among control households which continued to use their customary sources of drinking water. The filter systems produced water that consistently met WHO drinking-water standards despite levels of turbidity that presented a challenge to other low-cost POU treatment methods. The filter systems also demonstrated an ability to maintain the high quality of the treated water against subsequent re-contamination in the home.

  12. Patient-Centered Technological Assessment and Monitoring of Depression for Low-Income Patients

    PubMed Central

    Wu, Shinyi; Vidyanti, Irene; Liu, Pai; Hawkins, Caitlin; Ramirez, Magaly; Guterman, Jeffrey; Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Ell, Kathleen

    2014-01-01

    Depression is a significant challenge for ambulatory care because it worsens health status and outcomes, increases health care utilizations and costs, and elevates suicide risk. An automatic telephonic assessment (ATA) system that links with tasks and alerts to providers may improve quality of depression care and increase provider productivity. We used ATA system in a trial to assess and monitor depressive symptoms of 444 safety-net primary care patients with diabetes. We assessed system properties, evaluated preliminary clinical outcomes, and estimated cost savings. The ATA system is feasible, reliable, valid, safe, and likely cost-effective for depression screening and monitoring for low-income primary care population. PMID:24525531

  13. Magnetron sputtering source

    DOEpatents

    Makowiecki, D.M.; McKernan, M.A.; Grabner, R.F.; Ramsey, P.B.

    1994-08-02

    A magnetron sputtering source for sputtering coating substrates includes a high thermal conductivity electrically insulating ceramic and magnetically attached sputter target which can eliminate vacuum sealing and direct fluid cooling of the cathode assembly. The magnetron sputtering source design results in greater compactness, improved operating characteristics, greater versatility, and low fabrication cost. The design easily retrofits most sputtering apparatuses and provides for safe, easy, and cost effective target replacement, installation, and removal. 12 figs.

  14. Latin American Clinical Epidemiology Network Series - Paper 4: Economic evaluation of Kangaroo Mother Care: cost utility analysis of results from a randomized controlled trial conducted in Bogotá.

    PubMed

    Ruiz, Juan Gabriel; Charpak, Nathalie; Castillo, Mario; Bernal, Astrid; Ríos, John; Trujillo, Tammy; Córdoba, María Adelaida

    2017-06-01

    Although kangaroo mother care (KMC) has been shown to be safe and effective in randomized controlled trials (RCTs), there are no published complete economic evaluations including the three components of the full intervention. A cost utility analysis performed on the results of an RCT conducted in Bogotá, Colombia between 1993 and 1996. Hospital and ambulatory costs were estimated by microcosting in a sample of preterm infants from a University Hospital in Bogotá in 2011 and at a KMC clinic in the same period. Utility scores were assigned by experts by means of (1) direct ordering and scoring discrete health states and (2) constructing a multi-attribute utility function. Ninety-five percent confidence intervals (CIs) for the incremental cost-utility ratios (ICURs) were computed by the Fiellers theorem method. One-way sensitivity analysis on price estimates for valuing costs was performed. ICUR at 1 year of corrected age was $ -1,546 per extra quality-adjusted life year gained using the KMC method (95% CI $ -7,963 to $ 4,910). In Bogotá, the use of KMC is dominant: more effective and cost-saving. Although results from an economic analysis should not be extrapolated to different systems and communities, this dominant result suggests that KMC could be cost-effective in similar low and middle income countries settings. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Precise determination of the refractive index of suspended particles: light transmission as a function of refractive index mismatch

    NASA Astrophysics Data System (ADS)

    McClymer, J. P.

    2016-08-01

    Many fluids appear white because refractive index differences lead to multiple scattering. In this paper, we use safe, low-cost commercial index matching fluids to quantitatively study light transmission as a function of index mismatch, reduce multiple scattering to allow single scattering probes, and to precisely determine the index of refraction of suspended material. The transmission profile is compared with Rayleigh-Gans and Mie theory predictions. The procedure is accessible as a student laboratory project, while providing advantages over other standard methods of measuring the refractive index of an unknown nanoparticle, making it valuable to researchers.

  16. Comparison between two methodologies for urban drainage decision aid.

    PubMed

    Moura, P M; Baptista, M B; Barraud, S

    2006-01-01

    The objective of the present work is to compare two methodologies based on multicriteria analysis for the evaluation of stormwater systems. The first methodology was developed in Brazil and is based on performance-cost analysis, the second one is ELECTRE III. Both methodologies were applied to a case study. Sensitivity and robustness analyses were then carried out. These analyses demonstrate that both methodologies have equivalent results, and present low sensitivity and high robustness. These results prove that the Brazilian methodology is consistent and can be used safely in order to select a good solution or a small set of good solutions that could be compared with more detailed methods afterwards.

  17. Batteries for electric road vehicles.

    PubMed

    Goodenough, John B; Braga, M Helena

    2018-01-15

    The dependence of modern society on the energy stored in a fossil fuel is not sustainable. An immediate challenge is to eliminate the polluting gases emitted from the roads of the world by replacing road vehicles powered by the internal combustion engine with those powered by rechargeable batteries. These batteries must be safe and competitive in cost, performance, driving range between charges, and convenience. The competitive performance of an electric car has been demonstrated, but the cost of fabrication, management to ensure safety, and a short cycle life have prevented large-scale penetration of the all-electric road vehicle into the market. Low-cost, safe all-solid-state cells from which dendrite-free alkali-metal anodes can be plated are now available; they have an operating temperature range from -20 °C to 80 °C and they permit the design of novel high-capacity, high-voltage cathodes providing fast charge/discharge rates. Scale-up to large multicell batteries is feasible.

  18. Some Case Studies on Metal-Microbe Interactions to Remediate Heavy Metals- Contaminated Soils in Korea

    NASA Astrophysics Data System (ADS)

    Chon, Hyo-Taek

    2015-04-01

    Conventional physicochemical technologies to remediate heavy metals-contaminated soil have many problems such as low efficiency, high cost and occurrence of byproducts. Recently bioremediation technology is getting more and more attention. Bioremediation is defined as the use of biological methods to remediate and/or restore the contaminated land. The objectives of bioremediation are to degrade hazardous organic contaminants and to convert hazardous inorganic contaminants to less toxic compounds of safe levels. The use of bioremediation in the treatment of heavy metals in soils is a relatively new concept. Bioremediation using microbes has been developed to remove toxic heavy metals from contaminated soils in laboratory scale to the contaminated field sites. Recently the application of cost-effective and environment-friendly bioremediation technology to the heavy metals-contaminated sites has been gradually realized in Korea. The merits of bioremediation include low cost, natural process, minimal exposure to the contaminants, and minimum amount of equipment. The limitations of bioremediation are length of remediation, long monitoring time, and, sometimes, toxicity of byproducts for especially organic contaminants. From now on, it is necessary to prove applicability of the technologies to contaminated sites and to establish highly effective, low-cost and easy bioremediation technology. Four categories of metal-microbe interactions are generally biosorption, bioreduction, biomineralization and bioleaching. In this paper, some case studies of the above metal-microbe interactions in author's lab which were published recently in domestic and international journals will be introduced and summarized.

  19. Exploratory Development on an Electronic Safing and Arming Device for Ordnance Fuzing

    DTIC Science & Technology

    1983-02-01

    to the bridges. Two units were subjected to MIL-STD-331, Test 101, Jolt. The EBMs were placed in the S & A cavity of an M739 fuze body for this test...of the program was to explore a concept for a safe, reliable, general purpose, low cost, electronic, A ’ zsafing and arming ( S & A ) system for use in...breadboard model hardware of the electronic S & A device. The electronic S & A devicu consists of an explosive barrier moduls (EBM) explosive train

  20. Aqueous cathode for next-generation alkali-ion batteries.

    PubMed

    Lu, Yuhao; Goodenough, John B; Kim, Youngsik

    2011-04-20

    The lithium-ion batteries that ushered in the wireless revolution rely on electrode strategies that are being stretched to power electric vehicles. Low-cost, safe electrical-energy storage that enables better use of alternative energy sources (e.g., wind, solar, and nuclear) requires an alternative strategy. We report a demonstration of the feasibility of a battery having a thin, solid alkali-ion electrolyte separating a water-soluble redox couple as the cathode and lithium or sodium in a nonaqueous electrolyte as the anode. The cell operates without a catalyst and has high storage efficiency. The possibility of a flow-through mode for the cathode allows flexibility of the cell design for safe, large-capacity electrical-energy storage at an acceptable cost.

  1. The Statin–Iron Nexus: Anti-Inflammatory Intervention for Arterial Disease Prevention

    PubMed Central

    DePalma, Ralph G.; Shamayeva, Galina; Chow, Bruce K.

    2013-01-01

    Objectives. We postulated the existence of a statin–iron nexus by which statins improve cardiovascular disease outcomes at least partially by countering proinflammatory effects of excess iron stores. Methods. Using data from a clinical trial of iron (ferritin) reduction in advanced peripheral arterial disease, the Iron and Atherosclerosis Study, we compared effects of ferritin levels versus high-density lipoprotein to low-density lipoprotein ratios (both were randomization variables) on clinical outcomes in participants receiving and not receiving statins. Results. Statins increased high-density lipoprotein to low-density lipoprotein ratios and reduced ferritin levels by noninteracting mechanisms. Improved clinical outcomes were associated with lower ferritin levels but not with improved lipid status. Conclusions. There are commonalities between the clinical benefits of statins and the maintenance of physiologic iron levels. Iron reduction may be a safe and low-cost alternative to statins. PMID:23409890

  2. Cost of abortions in Zambia: A comparison of safe abortion and post abortion care.

    PubMed

    Parmar, Divya; Leone, Tiziana; Coast, Ernestina; Murray, Susan Fairley; Hukin, Eleanor; Vwalika, Bellington

    2017-02-01

    Unsafe abortion is a significant but preventable cause of maternal mortality. Although induced abortion has been legal in Zambia since 1972, many women still face logistical, financial, social, and legal obstacles to access safe abortion services, and undergo unsafe abortion instead. This study provides the first estimates of costs of post abortion care (PAC) after an unsafe abortion and the cost of safe abortion in Zambia. In the absence of routinely collected data on abortions, we used multiple data sources: key informant interviews, medical records and hospital logbooks. We estimated the costs of providing safe abortion and PAC services at the University Teaching Hospital, Lusaka and then projected these costs to generate indicative cost estimates for Zambia. Due to unavailability of data on the actual number of safe abortions and PAC cases in Zambia, we used estimates from previous studies and from other similar countries, and checked the robustness of our estimates with sensitivity analyses. We found that PAC following an unsafe abortion can cost 2.5 times more than safe abortion care. The Zambian health system could save as much as US$0.4 million annually if those women currently treated for an unsafe abortion instead had a safe abortion.

  3. The Role of Probabilistic Design Analysis Methods in Safety and Affordability

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.

    2016-01-01

    For the last several years, NASA and its contractors have been working together to build space launch systems to commercialize space. Developing commercial affordable and safe launch systems becomes very important and requires a paradigm shift. This paradigm shift enforces the need for an integrated systems engineering environment where cost, safety, reliability, and performance need to be considered to optimize the launch system design. In such an environment, rule based and deterministic engineering design practices alone may not be sufficient to optimize margins and fault tolerance to reduce cost. As a result, introduction of Probabilistic Design Analysis (PDA) methods to support the current deterministic engineering design practices becomes a necessity to reduce cost without compromising reliability and safety. This paper discusses the importance of PDA methods in NASA's new commercial environment, their applications, and the key role they can play in designing reliable, safe, and affordable launch systems. More specifically, this paper discusses: 1) The involvement of NASA in PDA 2) Why PDA is needed 3) A PDA model structure 4) A PDA example application 5) PDA link to safety and affordability.

  4. Assessing point-of-use ultraviolet disinfection for safe water in urban developing communities.

    PubMed

    Barstow, Christina K; Dotson, Aaron D; Linden, Karl G

    2014-12-01

    Residents of urban developing communities often have a tap in their home providing treated and sometimes filtered water but its microbial quality cannot be guaranteed. Point-of-use (POU) disinfection systems can provide safe drinking water to the millions who lack access to clean water in urban communities. While many POU systems exist, there are several concerns that can lead to low user acceptability, including low flow rate, taste and odor issues, high cost, recontamination, and ineffectiveness at treating common pathogens. An ultraviolet (UV) POU system was constructed utilizing developing community-appropriate materials and simple construction techniques based around an inexpensive low-wattage, low pressure UV bulb. The system was tested at the bench scale to characterize its hydrodynamic properties and microbial disinfection efficacy. Hydraulically the system most closely resembled a plug flow reactor with minor short-circuiting. The system was challenge tested and validated for a UV fluence of 50 mJ/cm(2) and greater, over varying flow rates and UV transmittances, corresponding to a greater than 4 log reduction of most pathogenic bacteria, viruses, and protozoa of public health concern. This study presents the designed system and testing results to demonstrate the potential architecture of a low-cost, open-source UV system for further prototyping and field-testing.

  5. 41 CFR 102-35.30 - What actions must I take or am I authorized to take regardless of the property disposition method?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Public Contracts and Property Management Federal Property Management Regulations System (Continued... of the disposition method used: (a) You must maintain property in a safe, secure, and cost-effective...

  6. Fission Surface Power for the Exploration and Colonization of Mars

    NASA Technical Reports Server (NTRS)

    Houts, Mike; Porter, Ron; Gaddis, Steve; Van Dyke, Melissa; Martin, Jim; Godfroy, Tom; Bragg-Sitton, Shannon; Garber, Anne; Pearson, Boise

    2006-01-01

    The colonization of Mars will require abundant energy. One potential energy source is nuclear fission. Terrestrial fission systems are highly developed and have the demonstrated ability to safely produce tremendous amounts of energy. In space, fission systems not only have the potential to safely generate tremendous amounts of energy, but could also potentially be used on missions where alternatives are not practical. Programmatic risks such as cost and schedule are potential concerns with fission surface power (FSP) systems. To be mission enabling, FSP systems must be affordable and programmatic risk must be kept acceptably low to avoid jeopardizing exploration efforts that may rely on FSP. Initial FSP systems on Mars could be "workhorse" units sized to enable the establishment of a Mars base and the early growth of a colony. These systems could be nearly identical to FSP systems used on the moon. The systems could be designed to be safe, reliable, and have low development and recurring costs. Systems could also be designed to fit on relatively small landers. One potential option for an early Mars FSP system would be a 100 kWt class, NaK cooled system analogous to space reactors developed and flown under the U.S. "SNAP" program or those developed and flown by the former Soviet Union ("BUK" reactor). The systems could use highly developed fuel and materials. Water and Martian soil could be used to provide shielding. A modern, high-efficiency power conversion subsystem could be used to reduce required reactor thermal power. This, in turn, would reduce fuel burnup and radiation damage .effects by reducing "nuclear" fuels and materials development costs. A realistic, non-nuclear heated and fully integrated technology demonstration unit (TDU) could be used to reduce cost and programmatic uncertainties prior to initiating a flight program.

  7. Safe Life Propulsion Design Technologies (3rd Generation Propulsion Research and Technology)

    NASA Technical Reports Server (NTRS)

    Ellis, Rod

    2000-01-01

    The tasks outlined in this viewgraph presentation on safe life propulsion design technologies (third generation propulsion research and technology) include the following: (1) Ceramic matrix composite (CMC) life prediction methods; (2) Life prediction methods for ultra high temperature polymer matrix composites for reusable launch vehicle (RLV) airframe and engine application; (3) Enabling design and life prediction technology for cost effective large-scale utilization of MMCs and innovative metallic material concepts; (4) Probabilistic analysis methods for brittle materials and structures; (5) Damage assessment in CMC propulsion components using nondestructive characterization techniques; and (6) High temperature structural seals for RLV applications.

  8. Feasibility and potential effect of a low-cost virtual reality system on reducing pain and anxiety in adult burn injury patients during physiotherapy in a developing country.

    PubMed

    Morris, Linzette Deidré; Louw, Quinette Abegail; Crous, Lynette Christine

    2010-08-01

    The purpose of this study was to ascertain the feasibility and potential effect of a low-cost VR system (eMagin Z800 3DVisor), used in conjunction with pharmacological analgesia, on reducing pain and anxiety in adult burn patients undergoing physiotherapy treatment, compared to pharmacologic analgesia alone at a South African hospital. Single-blind, within-subject study design. Pain and anxiety outcome measures were measured by a blinded assessor using the Numeric Pain Rating Scale and Burn Specific Pain and Anxiety Scale. Box-and-whisker plot method, Chi-square tests as well as the Student's paired t-test were used to analyze data. Eleven eligible adult burn patients consented to participate in this study (3 female, 8 male; median age 33 years: range 23-54 years). A marginal (p=0.06) to insignificant (p=0.13) difference between the two sessions (analgesia with VR and analgesia without VR) in reducing pain was found. No significant difference (p=0.58) was found between the two sessions (analgesia with VR and analgesia without VR) for anxiety. There seems to be a trend that the low-cost VR system, when added to routine pharmacological analgesics, is a safe technique and could be of considerable benefit if implemented into the pain management regime of burn units at a South African hospital.

  9. Study of a fail-safe abort system for an actively cooled hypersonic aircraft. Volume 1: Technical summary

    NASA Technical Reports Server (NTRS)

    Pirello, C. J.; Herring, R. L.

    1976-01-01

    Conceptual designs of a fail-safe abort system for hydrogen fueled actively cooled high speed aircraft are examined. The fail-safe concept depends on basically three factors: (1) a reliable method of detecting a failure or malfunction in the active cooling system, (2) the optimization of abort trajectories which minimize the descent heat load to the aircraft, and (3) fail-safe thermostructural concepts to minimize both the weight and the maximum temperature the structure will reach during descent. These factors are examined and promising approaches are evaluated based on weight, reliability, ease of manufacture and cost.

  10. TED-Time and life saving External Defibrillator for home-use.

    PubMed

    Weiss, Teddy A; Rosenheck, Shimon; Gorni, Shraga; Katz, Ioni; Mendelbaum, Mendel; Gilon, Dan

    2014-06-01

    Sudden Cardiac Death--SCD --is a major unmet health problem that needs urgent and prompt solution. AICDs are very expensive, risky and indicated for a small group of patients, at the highest risk. AEDs--Automatic External Defibrillators--are designed for public places and although safe, cannot enter the home-market due to their cost and need for constant, high-cost maintenance. We developed TED, a low-cost AED that derives its energy off the mains, designed for home-use, to save SCD victims' lives. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Final Report - Assessment of Testing Options for the NTR at the INL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howe, Steven D; McLing, Travis L; McCurry, Michael

    One of the main technologies that can be developed to dramatically enhance the human exploration of space is the nuclear thermal rocket (NTR). Several studies over the past thirty years have shown that the NTR can reduce the cost of a lunar outpost, reduce the risk of a human mission to Mars, enable fast transits for most missions throughout the solar system, and reduce the cost and time for robotic probes to deep space. Three separate committees of the National Research Council of the National Academy of Sciences have recommended that NASA develop the NTR. One of the primary issuesmore » in development of the NTR is the ability to verify a flight ready unit. Three main methods can be used to validate safe operation of a NTR: 1) Full power, full duration test in an above ground facility that scrubs the rocket exhaust clean of any fission products; 2) Full power , full duration test using the Subsurface Active Filtering of Exhaust (SAFE) technique to capture the exhaust in subsurface strata; 3) Test of the reactor fuel at temperature and power density in a driver reactor with subsequent first test of the fully integrated NTR in space. The first method, the above ground facility, has been studied in the past. The second method, SAFE, has been examined for application at the Nevada Test Site. The third method relies on the fact that the Nuclear Furnace series of tests in 1971 showed that the radioactive exhaust coming from graphite based fuel for the NTR could be completely scrubbed of fission products and the clean hydrogen flared into the atmosphere. Under funding from the MSFC, the Center for Space Nuclear Research (CSNR) at the Idaho National laboratory (INL) has completed a reexamination of Methods 2 and 3 for implementation at the INL site. In short, the effort performed the following: 1) Assess the geology of the INL site and determine a location suitable SAFE testing; 2) Perform calculations of gas transport throughout the geology; 3) Produce a cost estimate of a non-nuclear , sub-scale test using gas injection to validate the computational models; 4) Produce a preliminary cost estimate to build a nuclear furnace equivalent facility to test NTR fuel on a green field location on the INL site. The results show that the INL geology is substantially better suited to the SAFE testing method than the NTS site. The existence of impermeable interbeds just above the sub-surface aquifer ensure that no material from the test, radioactive or not, can enter the water table. Similar beds located just below the surface will prevent any gaseous products from reaching the surface for dispersion. The extremely high permeability of the strata between the interbeds allows rapid dispersion of the rocket exhaust. In addition, the high permeability suggests that a lower back-pressure may develop in the hole against the rocket thrust, which increases safety of operations. Finally, the cost of performing a sub-scale, non-nuclear verification experiment was determined to be $3M. The third method was assessed through discussions with INL staff resident at the site. In essence, any new Category I facility on any DOE site will cost in excess of $250M. Based on the results of this study, a cost estimate for testing a nuclear rocket at the INL site appears to be warranted. Given the fact that a new nuclear fuel may be possible that does not release any fission products, the SAFE testing option appears to be the most affordable.« less

  12. THREE PORT LAPAROSCOPIC APPENDECTOMY TECHNIQUE WITH LOW COST AND AESTHETIC ADVANTAGE

    PubMed Central

    DOMENE, Carlos Eduardo; VOLPE, Paula; HEITOR, Frederico Almeida

    2014-01-01

    Introduction Despite dating more than 30 years after the first laparoscopic appendectomy, ileocecal appendix resection is still performed by laparotomy in more than 90% of cases, in our country. Aim To describe a technique for laparoscopic removal of the ileocecal appendix with three portals, at low cost and very good aesthetic appearance. Technique Three incisions, one umbilical and two suprapubic are made; permanent material used comprises: grasping forceps, hook, scissors, needle holders, three metal trocars and four other usual instruments, and a single strand of cotton. There is no need to use of operative extractors bags, clips, endoloops, staples or bipolar or harmonic energy instruments. Allows triangulation and instrumentation in the conventional manner. Conclusion The proposed technique is safe and reproducible, easily teachable, at very low cost and can be applied in general hospitals with conventional laparoscopic equipment. PMID:25409972

  13. Comparative study of disinfectants for use in low-cost gravity driven household water purifiers.

    PubMed

    Patil, Rajshree A; Kausley, Shankar B; Balkunde, Pradeep L; Malhotra, Chetan P

    2013-09-01

    Point-of-use (POU) gravity-driven household water purifiers have been proven to be a simple, low-cost and effective intervention for reducing the impact of waterborne diseases in developing countries. The goal of this study was to compare commonly used water disinfectants for their feasibility of adoption in low-cost POU water purifiers. The potency of each candidate disinfectant was evaluated by conducting a batch disinfection study for estimating the concentration of disinfectant needed to inactivate a given concentration of the bacterial strain Escherichia coli ATCC 11229. Based on the concentration of disinfectant required, the size, weight and cost of a model purifier employing that disinfectant were estimated. Model purifiers based on different disinfectants were compared and disinfectants which resulted in the most safe, compact and inexpensive purifiers were identified. Purifiers based on bromine, tincture iodine, calcium hypochlorite and sodium dichloroisocyanurate were found to be most efficient, cost effective and compact with replacement parts costing US$3.60-6.00 for every 3,000 L of water purified and are thus expected to present the most attractive value proposition to end users.

  14. The effect of simulated flash heating pasteurisation and Holder pasteurisation on human milk oligosaccharides.

    PubMed

    Daniels, Brodie; Coutsoudis, Anna; Autran, Chloe; Amundson Mansen, Kimberly; Israel-Ballard, Kiersten; Bode, Lars

    2017-08-01

    Human milk oligosaccharides (HMOs) have important protective functions in human milk. A low-cost remote pasteurisation temperature-monitoring system has been designed using FoneAstra, a cell phone-based networked sensing system to monitor simulated flash heat pasteurisation. To compare the pasteurisation effect on HMOs of the FoneAstra FH method with the current Sterifeed Holder method used by human milk banks. Donor human milk samples (n = 48) were obtained from a human milk bank and pasteurised using the two pasteurisation methods. HMOs were purified from samples and labelled before separation using high-performance liquid chromatography. Concentrations of total HMOs, sialylated and fucosylated HMOs and individual HMOs using the two pasteurisation methods were compared using repeated-measures ANOVA. The study demonstrated no difference in total concentration of HMOs between the two pasteurisation methods and a small but significant increase in the total concentration of HMOs regardless of pasteurisation methods compared with controls (unpasteurised samples) (p<0.0001). The FoneAstra FH pasteurisation system does not negatively affect oligosaccharides in human milk and therefore is a possible alternative for providing safely sterilised human milk for low- and middle-income countries.

  15. Protective effect of Opuntia ficus-indica L. cladodes against UVA-induced oxidative stress in normal human keratinocytes.

    PubMed

    Petruk, Ganna; Di Lorenzo, Flaviana; Imbimbo, Paola; Silipo, Alba; Bonina, Andrea; Rizza, Luisa; Piccoli, Renata; Monti, Daria Maria; Lanzetta, Rosa

    2017-12-15

    Opuntia ficus-indica L. is known for its beneficial effects on human health, but still little is known on cladodes as a potent source of antioxidants. Here, a direct, economic and safe method was set up to obtain water extracts from Opuntia ficus-indica cladodes rich in antioxidant compounds. When human keratinocytes were pre-treated with the extract before being exposed to UVA radiations, a clear protective effect against UVA-induced stress was evidenced, as indicated by the inhibition of stress-induced processes, such as free radicals production, lipid peroxidation and GSH depletion. Moreover, a clear protective effect against apoptosis in pre-treated irradiated cells was evidenced. We found that eucomic and piscidic acids were responsible for the anti-oxidative stress action of cladode extract. In conclusion, a bioactive, safe, low-cost and high value-added extract from Opuntia cladodes was obtained to be used for skin health/protection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Cleaning Water Contaminated with Heavy Metal Ions Using Pyrolyzed Biochar Adsorbents

    EPA Science Inventory

    The extraction of pollutants from water using activated biochar materials is a low cost, sustainable approach for providing safe water in developing countries. The adsorption of copper ions, Cu (II), onto banana peels that were dried, pyrolyzed and activated was studied and compa...

  17. Comparison and Cost Analysis of Drinking Water Quality Monitoring Requirements versus Practice in Seven Developing Countries

    PubMed Central

    Crocker, Jonny; Bartram, Jamie

    2014-01-01

    Drinking water quality monitoring programs aim to support provision of safe drinking water by informing water quality management. Little evidence or guidance exists on best monitoring practices for low resource settings. Lack of financial, human, and technological resources reduce a country’s ability to monitor water supply. Monitoring activities were characterized in Cambodia, Colombia, India (three states), Jordan, Peru, South Africa, and Uganda according to water sector responsibilities, monitoring approaches, and marginal cost. The seven study countries were selected to represent a range of low resource settings. The focus was on monitoring of microbiological parameters, such as E. coli, coliforms, and H2S-producing microorganisms. Data collection involved qualitative and quantitative methods. Across seven study countries, few distinct approaches to monitoring were observed, and in all but one country all monitoring relied on fixed laboratories for sample analysis. Compliance with monitoring requirements was highest for operational monitoring of large water supplies in urban areas. Sample transport and labor for sample collection and analysis together constitute approximately 75% of marginal costs, which exclude capital costs. There is potential for substantive optimization of monitoring programs by considering field-based testing and by fundamentally reconsidering monitoring approaches for non-piped supplies. This is the first study to look quantitatively at water quality monitoring practices in multiple developing countries. PMID:25046632

  18. Development of an SPE/CE method for analyzing HAAs

    USGS Publications Warehouse

    Zhang, L.; Capel, P.D.; Hozalski, R.M.

    2007-01-01

    The haloacetic acid (HAA) analysis methods approved by the US Environmental Protection Agency involve extraction and derivatization of HAAs (typically to their methyl ester form) and analysis by gas chromatography (GC) with electron capture detection (ECD). Concerns associated with these methods include the time and effort of the derivatization process, use of potentially hazardous chemicals or conditions during methylation, poor recoveries because of low extraction efficiencies for some HAAs or matrix effects from sulfate, and loss of tribromoacetic acid because of decarboxylation. The HAA analysis method introduced here uses solid-phase extraction (SPE) followed by capillary electrophoresis (CE) analysis. The method is accurate, reproducible, sensitive, relatively safe, and easy to perform, and avoids the use of large amounts of solvent for liquid-liquid extraction and the potential hazards and hassles of derivatization. The cost of analyzing HAAs using this method should be lower than the currently approved methods, and utilities with a GC/ECD can perform the analysis in-house.

  19. Safe Passage Data Analysis: Interim Report

    DOT National Transportation Integrated Search

    1993-04-01

    The purpose of this report is to describe quantitatively the costs and benefits of screener : proficiency evaluation and reporting systems (SPEARS) equipment, particularly computer-based : instruction (CBI) systems, compared to current methods of tra...

  20. Efficacy of a Low-Cost Bubble CPAP System in Treatment of Respiratory Distress in a Neonatal Ward in Malawi

    PubMed Central

    Kawaza, Kondwani; Machen, Heather E.; Brown, Jocelyn; Mwanza, Zondiwe; Iniguez, Suzanne; Gest, Al; Smith, E. O'Brian; Oden, Maria; Richards-Kortum, Rebecca R.; Molyneux, Elizabeth

    2014-01-01

    Background Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP) is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care. Methods We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups. Findings 87 neonates (62 bCPAP, 25 controls) were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62) compared with 44.0% (11/25) for controls. 65.5% (19/29) of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13) of controls. 64.6% (31/48) of neonates with respiratory distress syndrome (RDS) receiving bCPAP survived to discharge, compared to 23.5% (4/17) of controls. 61.5% (16/26) of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived. Interpretation Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries. PMID:24489715

  1. Low-Cost III-V Photovoltaic Materials by Chloride Vapor Transport Deposition Using Safe Solid Precursors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boettcher, Shannon; Aloni, Shaul; Weiss, Robert

    Si-based photovoltaic devices dominate the market. As photovoltaic (PV) manufacturing costs have plummeted, technologies which increase efficiency have become critical. Si cell efficiencies are nearing theoretical limits and Si-based PV modules are unlikely to reach the 25-30% efficiency range. The use of III-V semiconductors is an obvious technical solution to improve efficiency, especially if they can be integrated directly with existing Si technology as tandems. High coefficients of light absorption along with tunable bandgaps and lattice constants have resulted in record conversion efficiencies for both one-sun and concentrator PV applications. GaAs, for example, has been used to manufacture single-junction photovoltaicsmore » with world-record efficiencies of 28.8% at one sun.2 However, costs for III-Vs must be dramatically reduced to produce cost-effective, high-efficiency PV solutions. III-V costs are controlled by two factors: semiconductor growth and the substrate. III-V growth is dominated today by metal-organic vapor phase epitaxy (MOVPE) with a lesser role played by molecular beam epitaxy (MBE). MOVPE costs are high due to the expense and low utilization (~30%) of precursors, modest growth rates (~100 nm min-1), equipment complexity, and safety infrastructure needed to handle toxic, pyrophoric gases.3 MBE costs are high due to slow growth rates and limitations of scalability. Details comparing plausible low-cost III-V growth methods are available in a review article published as a result of this project. The primary goal of this project was to demonstrate that close-spaced vapor transport (CSVT) using chloride (from HCl) as a transport agent can be used for the rapid growth of device-ready III-V layers from safe, solid-source precursors. In pursuit of this goal, we designed, built, and installed a new Cl-CSVT reactor based on insights from our previous H2O-CSVT growth system and in collaboration with equipment professionals at Malachite Technologies. This system was successfully used to grow epitaxial GaAs with controlled n-type doping, having mobilities similar to MOVPE. Detailed technical information and results can also be found in the primary publication resulting from this project. This work sets the stage for tackling the development of high-performance III-V single junctions and tandem devices directly on Si substrates, which was beyond the capabilities of our H2O-CSVT system. The design of the reactor’s source and substrate transfer system should allow for direct deposition of device structures. The collective innovations of our Cl-CSVT system might ultimately serve as an enabling process for commercialization of the technology through a collaboration with appropriate industrial partners.« less

  2. Energy Storage for the Power Grid

    ScienceCinema

    Imhoff, Carl; Vaishnav, Dave; Wang, Wei

    2018-05-30

    The iron vanadium redox flow battery was developed by researchers at Pacific Northwest National Laboratory as a solution to large-scale energy storage for the power grid. This technology provides the energy industry and the nation with a reliable, stable, safe, and low-cost storage alternative for a cleaner, efficient energy future.

  3. 25 Low-Cost Biology Investigations.

    ERIC Educational Resources Information Center

    Beller, Joel

    This book is a compilation of biology labs that are safe, simple, dependable, economical, and diverse. Some of the 25 investigations contained within this book involve organisms that are free for the taking and returned to the environment unharmed following the investigations. Students gain experience in making observations, forming hypotheses,…

  4. Food, fibre, bile acids and the pelvic floor: An integrated low risk low cost approach to managing irritable bowel syndrome

    PubMed Central

    Philpott, Hamish; Nandurkar, Sanjay; Lubel, John; Gibson, Peter R

    2015-01-01

    Patients presenting with abdominal pain and diarrhea are often labelled as suffering from irritable bowel syndrome, and medications may be used often without success. Advances in the understanding of the causes of the symptoms (including pelvic floor weakness and incontinence, bile salt malabsorption and food intolerance) mean that effective, safe and well tolerated treatments are now available. PMID:26525925

  5. An Aqueous Ca-Ion Battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gheytani, Saman; Liang, Yanliang; Wu, Feilong

    Multivalent-ion batteries are emerging as low-cost, high energy density, and safe alternatives to Li-ion batteries but are challenged by slow cation diffusion in electrode materials due to the high polarization strength of Mg- and Al-ions. In contrast, Ca-ion has a low polarization strength similar to that of Li-ion, therefore a Ca-ion battery will share the advantages while avoiding the kinetics issues related to multivalent batteries. However, there is no battery known that utilizes the Ca-ion chemistry due to the limited success in Ca-ion storage materials. Here, a safe and low-cost aqueous Ca-ion battery based on a highly reversible polyimide anodemore » and a high-potential open framework copper hexacyanoferrate cathode is demonstrated. The prototype cell shows a stable capacity and high efficiency at both high and low current rates, with an 88% capacity retention and an average 99% coloumbic efficiency after cycling at 10C for 1000 cycles. The Ca-ion storage mechanism for both electrodes as well as the origin of the fast kinetics have been investigated. Finally, additional comparison with a Mg-ion cell with identical electrodes reveals clear kinetics advantages for the Ca-ion system, which is explained by the smaller ionic radii and more facile desolvation of hydrated Ca-ions.« less

  6. An Aqueous Ca-Ion Battery.

    PubMed

    Gheytani, Saman; Liang, Yanliang; Wu, Feilong; Jing, Yan; Dong, Hui; Rao, Karun K; Chi, Xiaowei; Fang, Fang; Yao, Yan

    2017-12-01

    Multivalent-ion batteries are emerging as low-cost, high energy density, and safe alternatives to Li-ion batteries but are challenged by slow cation diffusion in electrode materials due to the high polarization strength of Mg- and Al-ions. In contrast, Ca-ion has a low polarization strength similar to that of Li-ion, therefore a Ca-ion battery will share the advantages while avoiding the kinetics issues related to multivalent batteries. However, there is no battery known that utilizes the Ca-ion chemistry due to the limited success in Ca-ion storage materials. Here, a safe and low-cost aqueous Ca-ion battery based on a highly reversible polyimide anode and a high-potential open framework copper hexacyanoferrate cathode is demonstrated. The prototype cell shows a stable capacity and high efficiency at both high and low current rates, with an 88% capacity retention and an average 99% coloumbic efficiency after cycling at 10C for 1000 cycles. The Ca-ion storage mechanism for both electrodes as well as the origin of the fast kinetics have been investigated. Additional comparison with a Mg-ion cell with identical electrodes reveals clear kinetics advantages for the Ca-ion system, which is explained by the smaller ionic radii and more facile desolvation of hydrated Ca-ions.

  7. An Aqueous Ca-Ion Battery

    DOE PAGES

    Gheytani, Saman; Liang, Yanliang; Wu, Feilong; ...

    2017-10-26

    Multivalent-ion batteries are emerging as low-cost, high energy density, and safe alternatives to Li-ion batteries but are challenged by slow cation diffusion in electrode materials due to the high polarization strength of Mg- and Al-ions. In contrast, Ca-ion has a low polarization strength similar to that of Li-ion, therefore a Ca-ion battery will share the advantages while avoiding the kinetics issues related to multivalent batteries. However, there is no battery known that utilizes the Ca-ion chemistry due to the limited success in Ca-ion storage materials. Here, a safe and low-cost aqueous Ca-ion battery based on a highly reversible polyimide anodemore » and a high-potential open framework copper hexacyanoferrate cathode is demonstrated. The prototype cell shows a stable capacity and high efficiency at both high and low current rates, with an 88% capacity retention and an average 99% coloumbic efficiency after cycling at 10C for 1000 cycles. The Ca-ion storage mechanism for both electrodes as well as the origin of the fast kinetics have been investigated. Finally, additional comparison with a Mg-ion cell with identical electrodes reveals clear kinetics advantages for the Ca-ion system, which is explained by the smaller ionic radii and more facile desolvation of hydrated Ca-ions.« less

  8. Structures for the 3rd Generation Reusable Concept Vehicle

    NASA Technical Reports Server (NTRS)

    Hrinda, Glenn A.

    2001-01-01

    A major goal of NASA is to create an advance space transportation system that provides a safe, affordable highway through the air and into space. The long-term plans are to reduce the risk of crew loss to 1 in 1,000,000 missions and reduce the cost of Low-Earth Orbit by a factor of 100 from today's costs. A third generation reusable concept vehicle (RCV) was developed to assess technologies required to meet NASA's space access goals. The vehicle will launch from Cape Kennedy carrying a 25,000 lb. payload to the International Space Station (ISS). The system is an air breathing launch vehicle (ABLV) hypersonic lifting body with rockets and uses triple point hydrogen and liquid oxygen propellant. The focus of this paper is on the structural concepts and analysis methods used in developing the third generation reusable launch vehicle (RLV). Member sizes, concepts and material selections will be discussed as well as analysis methods used in optimizing the structure. Analysis based on the HyperSizer structural sizing software will be discussed. Design trades required to optimize structural weight will be presented.

  9. Soil vapor extraction with dewatering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, N.R.

    1996-08-01

    The physical treatment technology of soil vapor extraction (SVE) is reliable, safe, robust, and able to remove significant amounts of mass at a relatively low cost. SVE combined with a pump-and-treat system to create a dewatered zone has the opportunity to remove more mass with the added cost of treating the extracted groundwater. Various limiting processes result in a significant reduction in the overall mass removal rates from a SVE system in porous media. Only pilot scale, limited duration SVE tests conducted in low permeability media have been reported in the literature. It is expected that the presence of amore » fracture network in low permeability media will add another complexity to the limiting conditions surrounding the SVE technology. 20 refs., 4 figs.« less

  10. An Economic Analysis of a Safe Resident Handling Program in Nursing Homes

    PubMed Central

    Lahiri, Supriya; Latif, Saira; Punnett, Laura

    2018-01-01

    Background Occupational injuries, especially back problems related to resident handling, are common in nursing home employees and their prevention may require substantial up-front investment. This study evaluated the economics of a safe resident handling program (SRHP), in a large chain of skilled nursing facilities, from the corporation's perspective. Methods The company provided data on program costs, compensation claims, and turnover rates (2003-2009). Workers' compensation and turnover costs before and after the intervention were compared against investment costs using the “net-cost model”. Results Among 110 centers, the overall benefit-to-cost ratio was 1.7–3.09 and the payback period was 1.98–1.06 year (using alternative turnover cost estimates). The average annualized net savings per bed for the 110 centers (using company based turnover cost estimates) was $143, with a 95% confidence interval of $22–$264. This was very similar to the average annualized net savings per full time equivalent (FTE) staff member, which was $165 (95% confidence interval $22–$308). However, at 49 centers costs exceeded benefits. Conclusions Decreased costs of worker injury compensation claims and turnover appear at least partially attributable to the SRHP. Future research should examine center-specific factors that enhance program success, and improve measures of turnover costs and healthcare productivity. PMID:23203729

  11. Strategies for Providing Low-Cost Water Immersion Therapy With Limited Resources.

    PubMed

    Brickhouse, Brenda; Isaacs, Christine; Batten, Meghann; Price, Amber

    At our university-affiliated medical center, a major renovation of the women's health and birthing unit resulted in the temporary loss of the permanent tub used for water immersion therapy during labor. Because 40 percent of the women in the nurse-midwifery practice utilize hydrotherapy, we undertook a rigorous search for an interim solution. We developed a safe and cost-effective strategy that can be easily replicated and utilized by others to provide hydrotherapy for laboring women. © 2015 AWHONN.

  12. End-user perspective of low-cost sensors for outdoor air pollution monitoring.

    PubMed

    Rai, Aakash C; Kumar, Prashant; Pilla, Francesco; Skouloudis, Andreas N; Di Sabatino, Silvana; Ratti, Carlo; Yasar, Ansar; Rickerby, David

    2017-12-31

    Low-cost sensor technology can potentially revolutionise the area of air pollution monitoring by providing high-density spatiotemporal pollution data. Such data can be utilised for supplementing traditional pollution monitoring, improving exposure estimates, and raising community awareness about air pollution. However, data quality remains a major concern that hinders the widespread adoption of low-cost sensor technology. Unreliable data may mislead unsuspecting users and potentially lead to alarming consequences such as reporting acceptable air pollutant levels when they are above the limits deemed safe for human health. This article provides scientific guidance to the end-users for effectively deploying low-cost sensors for monitoring air pollution and people's exposure, while ensuring reasonable data quality. We review the performance characteristics of several low-cost particle and gas monitoring sensors and provide recommendations to end-users for making proper sensor selection by summarizing the capabilities and limitations of such sensors. The challenges, best practices, and future outlook for effectively deploying low-cost sensors, and maintaining data quality are also discussed. For data quality assurance, a two-stage sensor calibration process is recommended, which includes laboratory calibration under controlled conditions by the manufacturer supplemented with routine calibration checks performed by the end-user under final deployment conditions. For large sensor networks where routine calibration checks are impractical, statistical techniques for data quality assurance should be utilised. Further advancements and adoption of sophisticated mathematical and statistical techniques for sensor calibration, fault detection, and data quality assurance can indeed help to realise the promised benefits of a low-cost air pollution sensor network. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Offering Women Childbirth Choices: A Case for Nurse-Midwives and Free-Standing Birth Centers.

    ERIC Educational Resources Information Center

    Heffron, Marsha S.

    2002-01-01

    Describes the use of Certified Nurse Midwives and birth centers, examining how they present a safe, alternative maternity care option for low-risk women and discussing safety issues to consider with alternative childbirth experiences, birth center licensure and accreditation, cost effectiveness of freestanding birth centers, and client…

  14. Pesticide Regulations

    Science.gov Websites

    costs and benefits of pesticides to society. They try to identify the potential risks on human health ; Environment Human Health Animal Health Safe Use Practices Food Safety Environment Air Water Soil Wildlife Ingredients Low-Risk Pesticides Organic Pesticide Ingredients Pesticide Incidents Human Exposure Pet Exposure

  15. Drying and decontamination of pistachios with sequential infrared drying, tempering and hot air drying

    USDA-ARS?s Scientific Manuscript database

    The pistachio industry is in need of improved drying technology as the current hot air drying has low energy efficiency and drying rate and high labor cost and also does not produce safe products against microbial contamination. In the current study, dehulled and water- sorted pistachios with a mois...

  16. 64.1: Display Technologies for Therapeutic Applications of Virtual Reality

    PubMed Central

    Hoffman, Hunter G.; Schowengerdt, Brian T.; Lee, Cameron M.; Magula, Jeff; Seibel, Eric J.

    2015-01-01

    A paradigm shift in image source technology for VR helmets is needed. Using scanning fiber displays to replace LCD displays creates lightweight, safe, low cost, wide field of view, portable VR goggles ideal for reducing pain during severe burn wound care in hospitals and possibly in austere combat-transport environments. PMID:26146424

  17. Modeling the Impact of Uganda’s Safe Male Circumcision Program: Implications for Age and Regional Targeting

    PubMed Central

    Kripke, Katharine; Vazzano, Andrea; Kirungi, William; Musinguzi, Joshua; Opio, Alex; Ssempebwa, Rhobbinah; Nakawunde, Susan; Kyobutungi, Sheila; Akao, Juliet N.; Magala, Fred; Mwidu, George; Castor, Delivette

    2016-01-01

    Background Uganda aims to provide safe male circumcision (SMC) to 80% of men ages 15–49 by 2016. To date, only 2 million men have received SMC of the 4.2 million men required. In response to age and regional trends in SMC uptake, the country sought to re-examine its targets with respect to age and subnational region, to assess the program’s progress, and to refine the implementation approach. Methods and Findings The Decision Makers’ Program Planning Tool, Version 2.0 (DMPPT 2.0), was used in conjunction with incidence projections from the Spectrum/AIDS Impact Module (AIM) to conduct this analysis. Population, births, deaths, and HIV incidence and prevalence were used to populate the model. Baseline male circumcision prevalence was derived from the 2011 AIDS Indicator Survey. Uganda can achieve the most immediate impact on HIV incidence by circumcising men ages 20–34. This group will also require the fewest circumcisions for each HIV infection averted. Focusing on men ages 10–19 will offer the greatest impact over a 15-year period, while focusing on men ages 15–34 offers the most cost-effective strategy over the same period. A regional analysis showed little variation in cost-effectiveness of scaling up SMC across eight regions. Scale-up is cost-saving in all regions. There is geographic variability in program progress, highlighting two regions with low baseline rates of circumcision where additional efforts will be needed. Conclusion Focusing SMC efforts on specific age groups and regions may help to accelerate Uganda’s SMC program progress. Policy makers in Uganda have already used model outputs in planning efforts, proposing males ages 10–34 as a priority group for SMC in the 2014 application to the Global Fund’s new funding model. As scale-up continues, the country should also consider a greater effort to expand SMC in regions with low MC prevalence. PMID:27410234

  18. Research on the theory and application of adsorbed natural gas used in new energy vehicles: A review

    NASA Astrophysics Data System (ADS)

    Nie, Zhengwei; Lin, Yuyi; Jin, Xiaoyi

    2016-09-01

    Natural gas, whose primary constituent is methane, has been considered a convincing alternative for the growth of the energy supply worldwide. Adsorbed natural gas (ANG), the most promising methane storage method, has been an active field of study in the past two decades. ANG constitutes a safe and low-cost way to store methane for natural gas vehicles at an acceptable energy density while working at substantially low pressures (3.5-4.0 MPa), allowing for conformable store tank. This work serves to review the state-of-the-art development reported in the scientific literature on adsorbents, adsorption theories, ANG conformable tanks, and related technologies on ANG vehicles. Patent literature has also been searched and discussed. The review aims at illustrating both achievements and problems of the ANG technologies- based vehicles, as well as forecasting the development trends and critical issues to be resolved of these technologies.

  19. The costs and cost effectiveness of providing first-trimester, medical and surgical safe abortion services in KwaZulu-Natal Province, South Africa

    PubMed Central

    Devjee, Jaymala; Moodley, Jack

    2017-01-01

    Background Despite a liberal abortion law, access to safe abortion services in South Africa is challenging for many women. Medication abortion was introduced in 2013, but its reach remains limited. We aimed to estimate the costs and cost effectiveness of providing first-trimester medication abortion and manual vacuum aspiration (MVA) services to inform planning for first-trimester service provision in South Africa and similar settings. Methods We obtained data on service provision and outcomes from an operations research study where medication abortion was introduced alongside existing MVA services in public hospitals in KwaZulu-Natal province. Clinical data were collected through interviews with first-trimester abortion clients and summaries completed by nurses performing the procedures. In parallel, we performed micro-costing at three of the study hospitals. Using a model built in Excel, we estimated the average cost per medical and surgical procedure and determined the cost per complete abortion performed. Results are presented in 2015 US dollars. Results A total of 1,129 women were eligible for a first trimester abortion at the three study sites. The majority (886, 78.5%) were eligible to choose their abortion procedure; 94.1% (n = 834) chose medication abortion. The total average cost per medication abortion was $63.91 (52.32–75.51). The total average cost per MVA was higher at $69.60 (52.62–86.57); though the cost ranges for the two procedures overlapped. Given average costs, the cost per complete medication abortion was lower than the cost per complete MVA despite three (0.4%) medication abortion women being hospitalized and two (0.3%) having ongoing pregnancies at study exit. Personnel costs were the largest component of the total average cost of both abortion methods. Conclusion This analysis supports the scale-up of medication abortion alongside existing MVA services in South Africa. Women can be offered a choice of methods, including medication abortion with MVA as a back-up, without increasing costs. PMID:28369061

  20. FLPP NGL Structural Subsystems Activity

    NASA Astrophysics Data System (ADS)

    Jaredson, D.; Ramusat, G.; Appel, S.; Cardone, T.; Persson, J.; Baiocco, P.; Lavelle, F.; Bouilly, Th.

    2012-07-01

    The ESA Future Launchers Preparatory Programme (FLPP) is the basis for new paradigms, investigating the key elements, logic and roadmaps to prepare the development of the safe, reliable and low cost next European Launch Vehicle (LV) for access to space (dubbed NGL - Next Generation LV), with an initial operational capability mid-next decade. In addition to carry cargo to conventional GTO or SSO, the European NGL has to be flexible enough to cope with new pioneering institutional missions as well as the evolving commercial payloads market. This achievement is broached studying three main areas relevant to ELVs: System concepts, Propulsion and Core Technology During the preliminary design activity, a number of design alternatives concerning NGL main structural subsystems have been investigated. Technology is one of the ways to meet the NGL challenges to either improve the performances or to reduce the cost or both. The relevant requirements allow to steer a ‘top-down’ approach for their conception and to propose the most effective technologies. Furthermore, all these technology developments represent a significant ‘bottom-up’ approach investment and concern a large range of activities. The structural subsystems portfolio of the FLPP ‘Core Technology’ activity encompasses major cutting-edge challenges for maturation of the various subsystems leading to reduce overall structural mass, increasing structural margins for robustness, metallic and composite containment of cryogenic propellants, significantly reducing fabrication and operations cost, etc. to derive performing upper and booster stages. Application of concurrent engineering methods will allow developments of performing technology demonstrators in terms of need, demonstration objective, size and cost yielding to safe, low-risk technical approaches for a future development. Potential ability of these advanced structural LV technologies to satisfy the system requirements of the NGL and their current and targeted technology readiness (i.e. TRL 6 by 2016) are being assessed to check whether a future flawless development could be performed within a given budget and schedule. The paper outlines the various technology developments for the pressurised and unpressurised structure subsystems and describes the implementation methodology, some of the current technology works performed and achieved accomplishments up to now. This is in strong connection with the “system” activity dealing with the same matter [1].

  1. Performance monitoring for safe and livable communities : fusing data, to improve arterial operations for all users.

    DOT National Transportation Integrated Search

    2014-10-01

    Measuring or analyzing transportation system performance occupies a large transportation professionals time. So, improving performance : measurement methods in terms of accuracy and cost are important contributions. This research documents develop...

  2. A Modified Cooling Method and Its Application in "Drosophila" Experiments

    ERIC Educational Resources Information Center

    Qu, Wen-hui; Zhu, Tong-bo; Yang, Da-Xiang

    2015-01-01

    Chilling is a cost-effective and safe method of immobilising flies in "Drosophila" experiments. However, should condensation form on the plate, it would be fatal to the flies. Here we describe a modified cooling method using reusable commercial ice pack(s) (ca. 400 ml, 2-3 cm tall) rather than crushed ice. The ice pack is covered with a…

  3. 78 FR 32558 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-31

    ...This action announces the U.S. Environmental Protection Agency's (EPA's) approval of alternative testing methods for use in measuring the levels of contaminants in drinking water and determining compliance with national primary drinking water regulations. The Safe Drinking Water Act (SDWA) authorizes EPA to approve the use of alternative testing methods through publication in the Federal Register. EPA is using this streamlined authority to make 84 additional methods available for analyzing drinking water samples. This expedited approach provides public water systems, laboratories, and primacy agencies with more timely access to new measurement techniques and greater flexibility in the selection of analytical methods, thereby reducing monitoring costs while maintaining public health protection.

  4. Power sources for search and rescue 406 MHz beacons

    NASA Technical Reports Server (NTRS)

    Attia, Alan I.; Perrone, David E.

    1987-01-01

    The results of a study directed at the selection of a commercially available, safe, low cost, light weight and long storage life battery for search and rescue (Sarsat) 406 MHz emergency beacons are presented. In the course of this work, five electrochemical systems (lithium-manganese dioxide, lithium-carbon monofluoride, lithium-silver vanadium oxide, alkaline cells, and cadmium-mercuric oxide) were selected for limited experimental studies to determine their suitability for this application. Two safe, commercially available batteries (lithium-manganese dioxide and lithium-carbon monofluoride) which meet the near term requirements and several alternatives for the long term were identified.

  5. Demonstration of the Low-Cost Virtual Collaborative Environment (VCE)

    NASA Technical Reports Server (NTRS)

    Bowers, David; Montes, Leticia; Ramos, Angel; Joyce, Brendan; Lumia, Ron

    1997-01-01

    This paper demonstrates the feasibility of a low-cost approach of remotely controlling equipment. Our demonstration system consists of a PC, the PUMA 560 robot with Barrett hand, and commercially available controller and teleconferencing software. The system provides a graphical user interface which allows a user to program equipment tasks and preview motions i.e., simulate the results. Once satisfied that the actions are both safe and accomplish the task, the remote user sends the data over the Internet to the local site for execution on the real equipment. A video link provides visual feedback to the remote sight. This technology lends itself readily to NASA's upcoming Mars expeditions by providing remote simulation and control of equipment.

  6. Novel Low-Cost Sensor for Human Bite Force Measurement

    PubMed Central

    Fastier-Wooller, Jarred; Phan, Hoang-Phuong; Dinh, Toan; Nguyen, Tuan-Khoa; Cameron, Andrew; Öchsner, Andreas; Dao, Dzung Viet

    2016-01-01

    This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement. PMID:27509496

  7. The costs and cost effectiveness of providing first-trimester, medical and surgical safe abortion services in KwaZulu-Natal Province, South Africa.

    PubMed

    Lince-Deroche, Naomi; Fetters, Tamara; Sinanovic, Edina; Devjee, Jaymala; Moodley, Jack; Blanchard, Kelly

    2017-01-01

    Despite a liberal abortion law, access to safe abortion services in South Africa is challenging for many women. Medication abortion was introduced in 2013, but its reach remains limited. We aimed to estimate the costs and cost effectiveness of providing first-trimester medication abortion and manual vacuum aspiration (MVA) services to inform planning for first-trimester service provision in South Africa and similar settings. We obtained data on service provision and outcomes from an operations research study where medication abortion was introduced alongside existing MVA services in public hospitals in KwaZulu-Natal province. Clinical data were collected through interviews with first-trimester abortion clients and summaries completed by nurses performing the procedures. In parallel, we performed micro-costing at three of the study hospitals. Using a model built in Excel, we estimated the average cost per medical and surgical procedure and determined the cost per complete abortion performed. Results are presented in 2015 US dollars. A total of 1,129 women were eligible for a first trimester abortion at the three study sites. The majority (886, 78.5%) were eligible to choose their abortion procedure; 94.1% (n = 834) chose medication abortion. The total average cost per medication abortion was $63.91 (52.32-75.51). The total average cost per MVA was higher at $69.60 (52.62-86.57); though the cost ranges for the two procedures overlapped. Given average costs, the cost per complete medication abortion was lower than the cost per complete MVA despite three (0.4%) medication abortion women being hospitalized and two (0.3%) having ongoing pregnancies at study exit. Personnel costs were the largest component of the total average cost of both abortion methods. This analysis supports the scale-up of medication abortion alongside existing MVA services in South Africa. Women can be offered a choice of methods, including medication abortion with MVA as a back-up, without increasing costs.

  8. [The current role of warfarin].

    PubMed

    Michalcová, Jana; Buliková, Alena; Zavřelová, Jiřina; Prudková, Marie; Penka, Miroslav

    Well-managed warfarin therapy remains an important method of anticoagulation in the 21st century, despite the introduction of new antithrombotics into the clinical practice. The main advantages of warfarin are decades of treatment experience, the possibility to monitor its anticoagulant effect using the INR and the last, but not least, the low cost. Currently, approximately 75 % of anticoagulated patients in the Czech Republic are treated with warfarin and warfarin remains the only option for oral anticoagulant therapy in certain clinical conditions (particularly in patients with valvular atrial fibrillation or mechanical heart valves). For physicians across specialties it is still indispensable to master the basics of safe and effective warfarin therapy, including the management of treatment complications.Key words: anticoagulant therapy - INR - thrombosis - warfarin.

  9. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  10. Dietary Supplements are Not all Safe and Not all Food: How the Low Cost of Dietary Supplements Preys on the Consumer.

    PubMed

    Sax, Joanna K

    2015-01-01

    Dietary supplements are regulated as food, even though the safety and efficacy of some supplements are unknown. These products are often promoted as 'natural.' This leads many consumers to fail to question the supplements' safety, and some consumers even equate 'natural' with safe. But, 'natural' does not mean safe. For example, many wild berries and mushrooms are dangerous although they are natural. Another example is tobacco--a key ingredient in cigarettes: it is natural, but overwhelming studies have established the harm of cigarette smoke. The Food and Drug Administration (FDA) requires safety and efficacy testing prior to market entry for drugs. In contrast, the FDA only has limited ability to regulate the entry of new dietary supplements into the marketplace because supplements are treated as food. Two main arguments support the current regulatory structure of dietary supplements: (1) cost and (2) access. But lower cost and increased access to dietary supplements do not necessary have any relationship to safety and efficacy. Manufacturers' marketing techniques tout the health benefits of their supplements. Meanwhile, consumers are ingesting supplements without scientific studies indicating whether or not they are harmful. The FDA Food Safety and Modernization Act, signed into law on January 4, 2011, did not address the safety concerns regarding dietary supplements. This article discusses the regulatory deficiencies concerning dietary supplements and proposes novel solutions to address this specific sector of the food supply. This article advocates for the use of scientific data to support a multi-tiered classification system to ensure that dietary supplements on the market are safe.

  11. Cable-driven elastic parallel humanoid head with face tracking for Autism Spectrum Disorder interventions.

    PubMed

    Su, Hao; Dickstein-Fischer, Laurie; Harrington, Kevin; Fu, Qiushi; Lu, Weina; Huang, Haibo; Cole, Gregory; Fischer, Gregory S

    2010-01-01

    This paper presents the development of new prismatic actuation approach and its application in human-safe humanoid head design. To reduce actuator output impedance and mitigate unexpected external shock, the prismatic actuation method uses cables to drive a piston with preloaded spring. By leveraging the advantages of parallel manipulator and cable-driven mechanism, the developed neck has a parallel manipulator embodiment with two cable-driven limbs embedded with preloaded springs and one passive limb. The eye mechanism is adapted for low-cost webcam with succinct "ball-in-socket" structure. Based on human head anatomy and biomimetics, the neck has 3 degree of freedom (DOF) motion: pan, tilt and one decoupled roll while each eye has independent pan and synchronous tilt motion (3 DOF eyes). A Kalman filter based face tracking algorithm is implemented to interact with the human. This neck and eye structure is translatable to other human-safe humanoid robots. The robot's appearance reflects a non-threatening image of a penguin, which can be translated into a possible therapeutic intervention for children with Autism Spectrum Disorders.

  12. Economic value of safe water for the infrastructurally disadvantaged urban household: A case study in Delhi, India

    NASA Astrophysics Data System (ADS)

    Dasgupta, Purnamita; Dasgupta, Rajib

    2004-11-01

    Delhi has witnessed rapid urbanization during the past 50 years, with ever increasing growth in population and economic activity leading to water stress in several parts of the city. This paper looks at the valuation of water as an economic resource in the context of a low-income, infrastructurally disadvantaged urban household, through the results of a primary survey. In doing so, it examines several issues, often interlinked, concerning the quality and quantity of water being "accessed" by households. While there is no one perfect way of estimating household demand for improved water services, the study uses the contingent valuation approach and evaluates the findings in terms of the health benefits from safe water and the costs of provision of safe supplies.

  13. Demonstrating the Efficacy of the FoneAstra Pasteurization Monitor for Human Milk Pasteurization in Resource-Limited Settings

    PubMed Central

    Coutsoudis, Anna; Israel-Ballard, Kiersten; Chaudhri, Rohit; Perin, Noah; Mlisana, Koleka

    2015-01-01

    Abstract Human milk provides crucial nutrition and immunologic protection for infants. When a mother's own milk is unavailable, donated human milk, pasteurized to destroy bacteria and viruses, is a lifesaving replacement. Flash-heat pasteurization is a simple, low-cost, and commonly used method to make milk safe, but currently there is no system to monitor milk temperature, which challenges quality control. FoneAstra, a smartphone-based mobile pasteurization monitor, removes this barrier by guiding users through pasteurization and documenting consistent and safe practice. This study evaluated FoneAstra's efficacy as a quality control system, particularly in resource-limited settings, by comparing bacterial growth in donor milk flash-heated with and without the device at a neonatal intensive care unit in Durban, South Africa. Materials and Methods: For 100 samples of donor milk, one aliquot each of prepasteurized milk, milk flash-heated without FoneAstra, and milk pasteurized with FoneAstra was cultured on routine agar for bacterial growth. Isolated bacteria were identified and enumerated. Results: In total, 300 samples (three from each donor sample) were analyzed. Bacterial growth was found in 86 of the 100 samples before any pasteurization and one of the 100 postpasteurized samples without FoneAstra. None of the samples pasteurized using FoneAstra showed bacterial growth. Conclusions: Both pasteurization methods were safe and effective. FoneAstra, however, provides the additional benefits of user-guided temperature monitoring and data tracking. By improving quality assurance and standardizing the pasteurization process, FoneAstra can support wide-scale implementation of human milk banks in resource-limited settings, increasing access and saving lives. PMID:25668396

  14. Kangaroo mother care for low birthweight infants: a randomized controlled trial in different settings.

    PubMed

    Cattaneo, A; Davanzo, R; Worku, B; Surjono, A; Echeverria, M; Bedri, A; Haksari, E; Osorno, L; Gudetta, B; Setyowireni, D; Quintero, S; Tamburlini, G

    1998-09-01

    A randomized controlled trial was carried out for 1 y in three tertiary and teaching hospitals, in Addis Ababa (Ethiopia), Yogyakarta (Indonesia) and Merida (Mexico), to study the effectiveness, feasibility, acceptability and cost of kangaroo mother care (KMC) when compared to conventional methods of care (CMC). About 29% of 649 low birthweight infants (LBWI; 1000-1999 g) died before eligibility. Of the survivors, 38% were excluded for various reasons, 149 were randomly assigned to KMC (almost exclusive skin-to-skin care after stabilization), and 136 to CMC (warm room or incubator care). There were three deaths in each group and no difference in the incidence of severe disease. Hypothermia was significantly less common in KMC infants in Merida (13.5 vs 31.5 episodes/100 infants/d) and overall (10.8 vs 14.6). Exclusive breastfeeding at discharge was more common in KMC infants in Merida (80% vs 16%) and overall (88% vs 70%). KMC infants had a higher mean daily weight gain (21.3 g vs 17.7 g) and were discharged earlier (13.4 vs 16.3 d after enrolment). KMC was considered feasible and presented advantages over CMC in terms of maintenance of equipment. Mothers expressed a clear preference for KMC and health workers found it safe and convenient. KMC was cheaper than CMC in terms of salaries (US$ 11,788 vs US$ 29,888) and other running costs (US$ 7501 vs US$ 9876). This study confirms that hospital KMC for stabilized LBWI 1000-1999 g is at least as effective and safe as CMC, and shows that it is feasible in different settings, acceptable to mothers of different cultures, and less expensive. Where exclusive breastfeeding is uncommon among LBWI, KMC may bring about an increase in its prevalence and duration, with consequent benefits for health and growth. For hospitals in low-income countries KMC may represent an appropriate use of scarce resources.

  15. Decoupling of Getting Up Detection Device Using Ultrasonic Radar by Changing Duty Ratio of Transmission Wave

    NASA Astrophysics Data System (ADS)

    Yamada, Yo; Tanaka, Kanya; Haruyama, Kazuo; Wakasa, Yuji; Akashi, Takuya

    The decline in the quality of patient's safety control is a problem, because the number of caretakers is reduced by the acceleration of demographic aging in an elder care facility. Especially, the detection of getting up from the bed is very important for preventing patients from falling and wandering unbreakable. In our previous study, we have developed the getting up detection device with an ultrasonic radar, which is safe, cheap, and break-proof. However, if there are many patients in a ward, it is difficult to use some ultrasonic radars. The reason is that if some ultrasonic radars, which have the same frequency, are used in same ward, the ultrasonic signals are coherent with each other. To solve this problem, we propose a novel incoherent method. This method is achieved by improving the software in the device at a low cost.

  16. Barriers and Facilitators to Adolescents' Use of Long-Acting Reversible Contraceptives.

    PubMed

    Pritt, Nicole M; Norris, Alison H; Berlan, Elise D

    2017-02-01

    Most pregnancies among teenagers are unintended and many can be attributed to contraception misuse or nonuse. The etonogestrel implant and intrauterine devices, referred to as long-acting reversible contraceptives, or LARCs, are the most effective reversible contraceptive methods. These methods are safe for use by adolescents, yet the number of LARC users remains low among adolescents in the United States. In this review we examine recent literature about barriers and facilitators to LARC use among adolescent women. Factors that influence decision-making and provision are organized into 4 categories: (1) cost and clinical operations; (2) adolescent awareness and attitudes; (3) confidentiality, consent, and parental attitudes; and (4) health care provider knowledge, attitudes, and counseling. Knowledge deficits and misconceptions among adolescents and their health care providers are key barriers to adolescent LARC use. Copyright © 2016 North American Society for Pediatric and Adolescent Gynecology. Published by Elsevier Inc. All rights reserved.

  17. The cost of postabortion care and legal abortion in Colombia.

    PubMed

    Prada, Elena; Maddow-Zimet, Isaac; Juarez, Fatima

    2013-09-01

    Although Colombia partially liberalized its abortion law in 2006, many abortions continue to occur outside the law and result in complications. Assessing the costs to the health care system of safe, legal abortions and of treating complications of unsafe, illegal abortions has important policy implications. The Post-Abortion Care Costing Methodology was used to produce estimates of direct and indirect costs of postabortion care and direct costs of legal abortions in Colombia. Data on estimated costs were obtained through structured interviews with key informants at a randomly selected sample of facilities that provide abortion-related care, including 25 public and private secondary and tertiary facilities and five primary-level private facilities that provide specialized reproductive health services. The median direct cost of treating a woman with abortion complications ranged from $44 to $141 (in U.S. dollars), representing an annual direct cost to the health system of about $14 million per year. A legal abortion at a secondary or tertiary facility was costly (medians, $213 and $189, respectively), in part because of the use of dilation and curettage, as well as because of administrative barriers. At specialized facilities, where manual vacuum aspiration and medication abortion are used, the median cost of provision was much lower ($45). Provision of postabortion care and legal abortion services at higher-level facilities results in unnecessarily high health care costs. These costs can be reduced significantly by providing services in a timely fashion at primary-level facilities and by using safe, noninvasive and less costly abortion methods.

  18. Effect of the PiAstra Benchtop Flash-Heating Pasteurizer on Immune Factors of Donor Human Milk.

    PubMed

    Daniels, Brodie; Reimers, Penny; King, Tracy; Schmidt, Stefan; Coutsoudis, Anna

    2018-05-01

    PiAstra is a simulated flash-heat (FH) pasteurization temperature monitoring system designed using Raspberry Pi technology for the pasteurization of human milk. This study analyzed the effect of the PiAstra FH method on human milk immune components (immunoglobulin A [IgA] and lactoferrin activity). Donor milk samples (N = 45) were obtained from a human milk bank, and pasteurized. Concentrations of IgA and lactoferrin activity were compared to their unpasteurized controls using the Student's t test. The PiAstra FH method retained 34.2% of IgA (p < 0.0001) and 40.4% of lactoferrin activity (p < 0.0001) when compared to unpasteurized controls. The retention of IgA by the PiAstra is similar to previous FH studies, while retention of lactoferrin activity was higher than previous FH studies. The high-technology, low-cost PiAstra system, which is able to retain vital immune components of human milk, provides safe donor milk for low-resourced settings. This enables the use of pasteurized donor milk when human milk is not available, potentially saving vulnerable infant lives.

  19. FNAC: its role, limitations and perspective in the preoperative diagnosis of breast cancer.

    PubMed

    Zagorianakou, P; Fiaccavento, S; Zagorianakou, N; Makrydimas, G; Stefanou, D; Agnantis, N J

    2005-01-01

    Fine-needle aspiration cytology (FNAC) was first described and performed in 1930. Thirty years later, it gained acceptance first in Europe and about a decade later in North America. The method is generally considered as a rapid, reliable, safe diagnostic tool to distinguish non-neoplastic from neoplastic breast lesions. In developed countries, in the last 20 years, mammographic screening programmes, which have been used extensively, are designed to detect the earliest possible breast cancer. The FNAC report is extremely important because it gives the necessary information for the management of patients, in order to proceed with more invasive diagnostic methods or surgical treatment, and to decide what kind of operation to perform. In the preoperative phase, FNAC has taken a fundamental role of both palpable and nonpalpable lesions, using ultrasound or stereotactic guidance. New developed techniques, breast biopsy instrumentation (ABBI) and mammotome have the advantage of complete removal of breast lesions, but this is not possible in all the examined cases. In developing countries, economical restrictions, low budget for health care and screening programmes put the patients at a disadvantage because of the high cost of sophisticated diagnostic methods, thus we recommend that FNAC be used as a routine diagnostic method because of its low cost compared with the others and this policy maximizes the availability of health care to women with breast cancer. We conclude that FNAC plays an important and essential role in the management of patients with breast lesions and also offers a great potential for prediction of patient outcome, disease response to therapy and assessment of risk of developing breast cancer. The reliability and efficiency of the method depends on the quality of the samples and the experience of the medical staff that performs the aspiration.

  20. Evaluating noninvasive genetic sampling techniques to estimate large carnivore abundance.

    PubMed

    Mumma, Matthew A; Zieminski, Chris; Fuller, Todd K; Mahoney, Shane P; Waits, Lisette P

    2015-09-01

    Monitoring large carnivores is difficult because of intrinsically low densities and can be dangerous if physical capture is required. Noninvasive genetic sampling (NGS) is a safe and cost-effective alternative to physical capture. We evaluated the utility of two NGS methods (scat detection dogs and hair sampling) to obtain genetic samples for abundance estimation of coyotes, black bears and Canada lynx in three areas of Newfoundland, Canada. We calculated abundance estimates using program capwire, compared sampling costs, and the cost/sample for each method relative to species and study site, and performed simulations to determine the sampling intensity necessary to achieve abundance estimates with coefficients of variation (CV) of <10%. Scat sampling was effective for both coyotes and bears and hair snags effectively sampled bears in two of three study sites. Rub pads were ineffective in sampling coyotes and lynx. The precision of abundance estimates was dependent upon the number of captures/individual. Our simulations suggested that ~3.4 captures/individual will result in a < 10% CV for abundance estimates when populations are small (23-39), but fewer captures/individual may be sufficient for larger populations. We found scat sampling was more cost-effective for sampling multiple species, but suggest that hair sampling may be less expensive at study sites with limited road access for bears. Given the dependence of sampling scheme on species and study site, the optimal sampling scheme is likely to be study-specific warranting pilot studies in most circumstances. © 2015 John Wiley & Sons Ltd.

  1. ESMO International Consortium Study on the availability, out-of-pocket costs and accessibility of antineoplastic medicines in countries outside of Europe

    PubMed Central

    Cherny, N I; Sullivan, R; Torode, J; Saar, M; Eniu, A

    2017-01-01

    Abstract Background The availability and affordability of safe, effective, high-quality, affordable anticancer therapies are a core requirement for effective national cancer control plans. Method Online survey based on a previously validated approach. The aims of the study were to evaluate (i) the availability on national formulary of licensed antineoplastic medicines across the globe, (ii) patient out-of-pocket costs for the medications, (iii) the actual availability of the medication for a patient with a valid prescription, (iv) information relating to possible factors adversely impacting the availability of antineoplastic agents and (v) the impact of the country’s level of economic development on these parameters. A total of 304 field reporters from 97 countries were invited to participate. The preliminary set of data was posted on the ESMO website for open peer review and amendments have been incorporated into the final report. Results Surveys were submitted by 135 reporters from 63 countries and additional peer-review data were submitted by 54 reporters from 19 countries. There are substantial differences in the formulary availability, out-of-pocket costs and actual availability for many anticancer medicines. The most substantial issues are in lower-middle- and low-income countries. Even among medications on the WHO Model List of Essential Medicines (EML) the discrepancies are profound and these relate to high out-of-pocket costs (in low-middle-income countries 32.0% of EML medicines are available only at full cost and 5.2% are not available at all, and for low-income countries, the corresponding figures are even worse at 57.7% and 8.3%, respectively). Conclusions There is wide global variation in formulary availability, out-of-pocket expenditures and actual availability for most licensed anticancer medicines. Low- and low-middle-income countries have significant lack of availability and high out-of-pocket expenditures for cancer medicines on the WHO EML, with much less availability of new, more expensive targeted agents compared with high-income countries. PMID:28950323

  2. Helping Clinicians Prevent Pregnancy among Sexually Active Adolescents: U.S. Medical Eligibility Criteria for Contraceptive Use and U.S. Selected Practice Recommendations for Contraceptive Use.

    PubMed

    Godfrey, Emily M

    2015-08-01

    The United States has made substantial progress in reducing teenage birth rates in recent decades, but rates remain high. Teen pregnancy can increase the risk of poor health outcomes and lead to decreased educational attainment, increased poverty, and welfare use, as well as increased cost to taxpayers. One of the most effective ways to prevent teenage pregnancy is through the use of effective birth control methods. The Centers for Disease Control (CDC) and Prevention has made the prevention of teenage pregnancy 1 of its 10 winnable battles. The CDC has released 2 evidence-based clinical guideline documents regarding contraceptive use for adolescents and adults. The first guideline, US Medical Eligibility Criteria for Contraceptive Use, 2010, helps clinicians recognize when a contraceptive method may not be safe to use for a particular adolescent but also when not to withhold a contraceptive method that is safe to use. The second document, US Selected Practice Recommendations for Contraceptive Use, 2013, provides guidance for how to use contraceptive methods safely and effectively once they are deemed safe. Health care providers are encouraged to use these documents to provide safe and effective contraceptive care to patients seeking family planning, including adolescents. Copyright © 2015 North American Society for Pediatric and Adolescent Gynecology. All rights reserved.

  3. Can active proton interrogation find shielded nuclear threats at human-safe radiation levels?

    NASA Astrophysics Data System (ADS)

    Liew, Seth Van

    2017-05-01

    A new method of low-dose proton radiography is presented. The system is composed of an 800 MeV proton source, bending magnets, and compact detectors, and is designed for drive-through cargo scanning. The system has been simulated using GEANT4. Material identification algorithms and pixel sorting methods are presented that allow the system to perform imaging at doses low enough to scan passenger vehicles and people. Results are presented on imaging efficacy of various materials and cluttered cargoes. The identification of shielded nuclear materials at human-safe doses has been demonstrated.

  4. EOS imaging versus current radiography: A health technology assessment study

    PubMed Central

    Mahboub-Ahari, Alireza; Hajebrahimi, Sakineh; Yusefi, Mahmoud; Velayati, Ashraf

    2016-01-01

    Background: EOS is a 2D/3D muscle skeletal diagnostic imaging system. The device has been developed to produce a high quality 2D, full body radiographs in standing, sitting and squatting positions. Three dimensional images can be reconstructed via sterEOS software. This Health Technology Assessment study aimed to investigate efficacy, effectiveness and cost-effectiveness of new emerged EOS imaging system in comparison with conventional x-ray radiographic techniques. Methods: All cost and outcome data were assessed from Iran's Ministry of Health Perspective. Data for clinical effectiveness was extracted using a rigorous systematic review. As clinical outcomes the rate of x-ray emission and related quality of life were compared with Computed Radiography (CR) and Digital Radiography (DR). Standard costing method was conducted to find related direct medical costs. In order to examine robustness of the calculated Incremental Cost Effectiveness Ratios (ICERs) we used two-way sensitivity analysis. GDP Per capita of Islamic Republic of Iran (2012) adopted as cost-effectiveness threshold. Results: Review of related literature highlighted the lack of rigorous evidence for clinical outcomes. Ultra low dose EOS imaging device is known as a safe intervention because of FDA, CE and CSA certificates. The rate of emitted X-ray was 2 to 18 fold lower for EOS compared to the conventional techniques (p<0.001). The Incremental Cost Effectiveness Ratio for EOS relative to CR calculated $50706 in baseline analysis (the first scenario) and $50714, $9446 respectively for the second and third scenarios. Considering the value of neither $42146 as upper limit, nor the first neither the second scenario could pass the cost-effectiveness threshold for Iran. Conclusion: EOS imaging technique might not be considered as a cost-effective intervention in routine practice of health system, especially within in-patient wards. Scenario analysis shows that, only in an optimum condition such as lower assembling costs and higher utilization rates, the device can be recruited for research and therapeutic purposes in pediatric orthopedic centers. PMID:27390701

  5. Demonstrating the efficacy of the FoneAstra pasteurization monitor for human milk pasteurization in resource-limited settings.

    PubMed

    Naicker, Mageshree; Coutsoudis, Anna; Israel-Ballard, Kiersten; Chaudhri, Rohit; Perin, Noah; Mlisana, Koleka

    2015-03-01

    Human milk provides crucial nutrition and immunologic protection for infants. When a mother's own milk is unavailable, donated human milk, pasteurized to destroy bacteria and viruses, is a lifesaving replacement. Flash-heat pasteurization is a simple, low-cost, and commonly used method to make milk safe, but currently there is no system to monitor milk temperature, which challenges quality control. FoneAstra, a smartphone-based mobile pasteurization monitor, removes this barrier by guiding users through pasteurization and documenting consistent and safe practice. This study evaluated FoneAstra's efficacy as a quality control system, particularly in resource-limited settings, by comparing bacterial growth in donor milk flash-heated with and without the device at a neonatal intensive care unit in Durban, South Africa. For 100 samples of donor milk, one aliquot each of prepasteurized milk, milk flash-heated without FoneAstra, and milk pasteurized with FoneAstra was cultured on routine agar for bacterial growth. Isolated bacteria were identified and enumerated. In total, 300 samples (three from each donor sample) were analyzed. Bacterial growth was found in 86 of the 100 samples before any pasteurization and one of the 100 postpasteurized samples without FoneAstra. None of the samples pasteurized using FoneAstra showed bacterial growth. Both pasteurization methods were safe and effective. FoneAstra, however, provides the additional benefits of user-guided temperature monitoring and data tracking. By improving quality assurance and standardizing the pasteurization process, FoneAstra can support wide-scale implementation of human milk banks in resource-limited settings, increasing access and saving lives.

  6. If nuclear energy is the answer, why doesn't everyone agree?

    NASA Astrophysics Data System (ADS)

    Roberts, J. W.

    2018-03-01

    Nuclear energy produces low carbon, safe and reliable electricity so is it now time for the UK to invest in this proven technology or are the misplaced perceptions regarding its safety, cost and the quantities of radioactive waste produced causing us to overlook nuclear as a major component of our electricity mix? This paper discusses these issues and whether the negative opinion of nuclear energy which could hold back it’s wider development in the UK, is justified in the 21st century. For the safe, secure and economic future of electricity can we afford to ignore the positive contributions nuclear energy can make any longer?

  7. CuCo2O4 nanoplate film as a low-cost, highly active and durable catalyst towards the hydrolytic dehydrogenation of ammonia borane for hydrogen production

    NASA Astrophysics Data System (ADS)

    Liu, Quanbing; Zhang, Shengjie; Liao, Jinyun; Feng, Kejun; Zheng, Yuying; Pollet, Bruno G.; Li, Hao

    2017-07-01

    Catalytic dehydrogenation of ammonia borane is one of the most promising routes for the production of clean hydrogen as it is seen as a highly efficient and safe method. However, its large-scale industrial application is either limited by the high cost of the catalyst (usually a noble metal based catalyst) or by the low activity and poor reusability (usually a non-noble metal catalyst). In this study, we have successfully prepared three low-cost CuCo2O4 nanocatalysts, namely: (i) Ti supported CuCo2O4 film made of CuCo2O4 nanoplates, (ii) Ti supported CuCo2O4 film made of CuCo2O4 nanosheets, and (iii) unsupported CuCo2O4 nanoparticles. Among the three catalysts used for the hydrolytic dehydrogeneration of ammonia borane, the CuCo2O4 nanoplate film exhibits the highest catalytic activity with a turnover frequency (TOF) of ∼44.0 molhydrogen min-1 molcat-1. This is one of the largest TOF value for noble-metal-free catalysts ever reported in the literature. Moreover, the CuCo2O4 nanoplate film almost keeps its original catalytic activity after eight cycles, indicative of its high stability and good reusability. Owing to its advantages, the CuCo2O4 nanoplate film can be a promising catalyst for the hydrolytic dehydrogenation of ammonia borane, which may find important applications in the field of hydrogen energy.

  8. Cost analysis of the History, ECG, Age, Risk factors, and initial Troponin (HEART) Pathway randomized control trial.

    PubMed

    Riley, Robert F; Miller, Chadwick D; Russell, Gregory B; Harper, Erin N; Hiestand, Brian C; Hoekstra, James W; Lefebvre, Cedric W; Nicks, Bret A; Cline, David M; Askew, Kim L; Mahler, Simon A

    2017-01-01

    The HEART Pathway is a diagnostic protocol designed to identify low-risk patients presenting to the emergency department with chest pain that are safe for early discharge. This protocol has been shown to significantly decrease health care resource utilization compared with usual care. However, the impact of the HEART Pathway on the cost of care has yet to be reported. We performed a cost analysis of patients enrolled in the HEART Pathway trial, which randomized participants to either usual care or the HEART Pathway protocol. For low-risk patients, the HEART Pathway recommended early discharge from the emergency department without further testing. We compared index visit cost, cost at 30 days, and cardiac-related health care cost at 30 days between the 2 treatment arms. Costs for each patient included facility and professional costs. Cost at 30 days included total inpatient and outpatient costs, including the index encounter, regardless of etiology. Cardiac-related health care cost at 30 days included the index encounter and costs adjudicated to be cardiac-related within that period. Two hundred seventy of the 282 patients enrolled in the trial had cost data available for analysis. There was a significant reduction in cost for the HEART Pathway group at 30 days (median cost savings of $216 per individual), which was most evident in low-risk (Thrombolysis In Myocardial Infarction score of 0-1) patients (median savings of $253 per patient) and driven primarily by lower cardiac diagnostic costs in the HEART Pathway group. Using the HEART Pathway as a decision aid for patients with undifferentiated chest pain resulted in significant cost savings. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. If Nuclear Energy Is the Answer, Why Doesn't Everyone Agree?

    ERIC Educational Resources Information Center

    Roberts, J. W.

    2018-01-01

    Nuclear energy produces low carbon, safe and reliable electricity so is it now time for the UK to invest in this proven technology or are the misplaced perceptions regarding its safety, cost and the quantities of radioactive waste produced causing us to overlook nuclear as a major component of our electricity mix? This paper discusses these issues…

  10. Ultrastrong Polyoxyzole Nanofiber Membranes for Dendrite-Proof and Heat-Resistant Battery Separators.

    PubMed

    Hao, Xiaoming; Zhu, Jian; Jiang, Xiong; Wu, Haitao; Qiao, Jinshuo; Sun, Wang; Wang, Zhenhua; Sun, Kening

    2016-05-11

    Polymeric nanomaterials emerge as key building blocks for engineering materials in a variety of applications. In particular, the high modulus polymeric nanofibers are suitable to prepare flexible yet strong membrane separators to prevent the growth and penetration of lithium dendrites for safe and reliable high energy lithium metal-based batteries. High ionic conductance, scalability, and low cost are other required attributes of the separator important for practical implementations. Available materials so far are difficult to comply with such stringent criteria. Here, we demonstrate a high-yield exfoliation of ultrastrong poly(p-phenylene benzobisoxazole) nanofibers from the Zylon microfibers. A highly scalable blade casting process is used to assemble these nanofibers into nanoporous membranes. These membranes possess ultimate strengths of 525 MPa, Young's moduli of 20 GPa, thermal stability up to 600 °C, and impressively low ionic resistance, enabling their use as dendrite-suppressing membrane separators in electrochemical cells. With such high-performance separators, reliable lithium-metal based batteries operated at 150 °C are also demonstrated. Those polyoxyzole nanofibers would enrich the existing library of strong nanomaterials and serve as a promising material for large-scale and cost-effective safe energy storage.

  11. Automated Testing Experience of the Linear Aerospike SR-71 Experiment (LASRE) Controller

    NASA Technical Reports Server (NTRS)

    Larson, Richard R.

    1999-01-01

    System controllers must be fail-safe, low cost, flexible to software changes, able to output health and status words, and permit rapid retest qualification. The system controller designed and tested for the aerospike engine program was an attempt to meet these requirements. This paper describes (1) the aerospike controller design, (2) the automated simulation testing techniques, and (3) the real time monitoring data visualization structure. Controller cost was minimized by design of a single-string system that used an off-the-shelf 486 central processing unit (CPU). A linked-list architecture, with states (nodes) defined in a user-friendly state table, accomplished software changes to the controller. Proven to be fail-safe, this system reported the abort cause and automatically reverted to a safe condition for any first failure. A real time simulation and test system automated the software checkout and retest requirements. A program requirement to decode all abort causes in real time during all ground and flight tests assured the safety of flight decisions and the proper execution of mission rules. The design also included health and status words, and provided a real time analysis interpretation for all health and status data.

  12. A decision analytic model to investigate the cost-effectiveness of poisoning prevention practices in households with young children.

    PubMed

    Achana, Felix; Sutton, Alex J; Kendrick, Denise; Hayes, Mike; Jones, David R; Hubbard, Stephanie J; Cooper, Nicola J

    2016-08-03

    Systematic reviews and a network meta-analysis show home safety education with or without the provision of safety equipment is effective in promoting poison prevention behaviours in households with children. This paper compares the cost-effectiveness of home safety interventions to promote poison prevention practices. A probabilistic decision-analytic model simulates healthcare costs and benefits for a hypothetical cohort of under 5 year olds. The model compares the cost-effectiveness of home safety education, home safety inspections, provision of free or low cost safety equipment and fitting of equipment. Analyses are conducted from a UK National Health Service and Personal Social Services perspective and expressed in 2012 prices. Education without safety inspection, provision or fitting of equipment was the most cost-effective strategy for promoting safe storage of medicines with an incremental cost-effectiveness ratio of £2888 (95 % credible interval (CrI) £1990-£5774) per poison case avoided or £41,330 (95%CrI £20,007-£91,534) per QALY gained compared with usual care. Compared to usual care, home safety interventions were not cost-effective in promoting safe storage of other household products. Education offers better value for money than more intensive but expensive strategies for preventing medicinal poisonings, but is only likely to be cost-effective at £30,000 per QALY gained for families in disadvantaged areas and for those with more than one child. There was considerable uncertainty in cost-effectiveness estimates due to paucity of evidence on model parameters. Policy makers should consider both costs and effectiveness of competing interventions to ensure efficient use of resources.

  13. The ‘cut and push’ technique: is it really safe?

    PubMed Central

    Peacock, Oliver; Singh, Rajeev; Cole, Andrew; Speake, William

    2012-01-01

    Percutaneous endoscopic gastrostomy (PEG) feeding is routinely used as an endoscopic and effective method for providing enteral nutrition in those whose oral access has been diminished or lost. One technique for removal of the PEG is cutting the tube at the skin level and allowing the tube and internal flange to pass spontaneously. This is known as the ‘cut and push’ method. Several studies have concluded that the ‘cut and push’ method is a safe and cost-effective method. This case demonstrates a rare cause of small bowel obstruction following the ‘cut and push’ method for PEG replacement, with only a few other cases been reported. This method of removal should be avoided in patients with previous abdominal surgery. It is important that the PEG flange is retrieved endoscopically or an alternative PEG tube (designed to be completely removed through the skin) is used to prevent this complication occurring in such individuals. PMID:22847571

  14. Relationships Analysis and Public Perception of the Healthy Plastic as One Solution to Healthy Living

    NASA Astrophysics Data System (ADS)

    Hartatik; Hartono, R.; Purnomo, A.; Riasti, B. K.; Munawaroh, H.

    2017-02-01

    Direct Plastics are used for various human purposes, ranging from household to industry. Tableware and drink made of plastic is very practical to use, easy to clean, durable and cost far less than tableware made of the other material. However, must also be considered in terms of security in the use of plastic containers for food storage because there are adverse effects. There are seven types of plastic based material used, namely Polyethylene, Terephthalate, High Density Polyethylene, Polyvinyl Chloride or V/PVC, Low Density Polyethylene or LDPE, Polypropylene, Polystyrene, Plastics others including polycarbonate. Experts claims that the plastic code numbers 2, 4 and 5 are used for equipment safely eat/drink because it is more stable and safe if used correctly. In this study will analyze the relationship between the recent education, family income to perception and behavior in the use of plastics in food storage daily as one solution to healthy living. The population of this research is all the people in the Solo area particularly housewife and all the people in the productive age. Data were obtained through a survey with cluster random sampling method. Statistical method used is a parametric method and Chi Square test This method is used as an alternative method of parametric when some assumptions are not met. Based on the results of Chi Square test with α = 15% was concluded that recent education and income related to the behavior of people using plastic products as one of the solutions to Healthy Living.

  15. Alternative antimicrobial commercial egg washing procedures

    USDA-ARS?s Scientific Manuscript database

    Commercial table eggs are washed prior to packaging. Standard wash procedures use an alkaline pH and warm water. If a cool water method could be developed that would still provide a microbiologically safe egg, the industry may save energy costs associated with water heating. Four wash procedures ...

  16. FINDING POTENTIALLY UNSAFE NUTRITIONAL SUPPLEMENTS FROM USER REVIEWS WITH TOPIC MODELING.

    PubMed

    Sullivan, Ryan; Sarker, Abeed; O'Connor, Karen; Goodin, Amanda; Karlsrud, Mark; Gonzalez, Graciela

    2016-01-01

    Although dietary supplements are widely used and generally are considered safe, some supplements have been identified as causative agents for adverse reactions, some of which may even be fatal. The Food and Drug Administration (FDA) is responsible for monitoring supplements and ensuring that supplements are safe. However, current surveillance protocols are not always effective. Leveraging user-generated textual data, in the form of Amazon.com reviews for nutritional supplements, we use natural language processing techniques to develop a system for the monitoring of dietary supplements. We use topic modeling techniques, specifically a variation of Latent Dirichlet Allocation (LDA), and background knowledge in the form of an adverse reaction dictionary to score products based on their potential danger to the public. Our approach generates topics that semantically capture adverse reactions from a document set consisting of reviews posted by users of specific products, and based on these topics, we propose a scoring mechanism to categorize products as "high potential danger", "average potential danger" and "low potential danger." We evaluate our system by comparing the system categorization with human annotators, and we find that the our system agrees with the annotators 69.4% of the time. With these results, we demonstrate that our methods show promise and that our system represents a proof of concept as a viable low-cost, active approach for dietary supplement monitoring.

  17. Approaches to acceptable risk

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whipple, C

    Several alternative approaches to address the question {open_quotes}How safe is safe enough?{close_quotes} are reviewed and an attempt is made to apply the reasoning behind these approaches to the issue of acceptability of radiation exposures received in space. The approaches to the issue of the acceptability of technological risk described here are primarily analytical, and are drawn from examples in the management of environmental health risks. These include risk-based approaches, in which specific quantitative risk targets determine the acceptability of an activity, and cost-benefit and decision analysis, which generally focus on the estimation and evaluation of risks, benefits and costs, inmore » a framework that balances these factors against each other. These analytical methods tend by their quantitative nature to emphasize the magnitude of risks, costs and alternatives, and to downplay other factors, especially those that are not easily expressed in quantitative terms, that affect acceptance or rejection of risk. Such other factors include the issues of risk perceptions and how and by whom risk decisions are made.« less

  18. Pediatric robotic urologic surgery-2014

    PubMed Central

    Kearns, James T.; Gundeti, Mohan S.

    2014-01-01

    We seek to provide a background of the current state of pediatric urologic surgery including a brief history, procedural outcomes, cost considerations, future directions, and the state of robotic surgery in India. Pediatric robotic urology has been shown to be safe and effective in cases ranging from pyeloplasty to bladder augmentation with continent urinary diversion. Complication rates are in line with other methods of performing the same procedures. The cost of robotic surgery continues to decrease, but setting up pediatric robotic urology programs can be costly in terms of both monetary investment and the training of robotic surgeons. The future directions of robot surgery include instrument and system refinements, augmented reality and haptics, and telesurgery. Given the large number of children in India, there is huge potential for growth of pediatric robotic urology in India. Pediatric robotic urologic surgery has been established as safe and effective, and it will be an important tool in the future of pediatric urologic surgery worldwide. PMID:25197187

  19. "Doing the heavy lifting: health care workers take back their backs".

    PubMed

    Morse, Tim; Fekieta, Renee; Rubenstein, Harriet; Warren, Nick; Alexander, Darryl; Wawzyniecki, Patricia

    2008-01-01

    Health care workers have the highest musculoskeletal disorder prevalence and incidence of any occupational/industry group, and patient handling tasks are so biomechanically demanding that they cannot be made safe through the commonly used, technique-oriented methods such as "back school" training programs. Although there is standard-setting activity for "no-lift" programs in some states, there is still no federal standard. Health care worker unions and nurses' associations have begun to take action through training members in equipment need, use, and acceptance in programs to encourage adoption of no-lifting programs. Acceptance of lifting equipment is increasing due to recognition of the high human and economic costs of MSD, consistent documentation of cost savings from no-lift programs, major improvements in lifting equipment, and shortages of health care staff. An action-oriented training program for health care workers is described that provides knowledge about the 1) Scope of the current problem of back injuries in health care, 2) Costs of injuries, both to workers and to the hospital, 3) Elements of a safe patient-handling program, and 4) Success stories. The program also builds skills through: 1) Hands-on experience with safe lifting equipment, and 2) Assessing organizational and union readiness and planning for action at the workplace.

  20. Cost-benefit analysis of copper recovery in remediation projects: A case study from Sweden.

    PubMed

    Volchko, Yevheniya; Norrman, Jenny; Rosén, Lars; Karlfeldt Fedje, Karin

    2017-12-15

    Contamination resulting from past industrial activity is a problem throughout the world and many sites are severely contaminated by metals. Advances in research in recent years have resulted in the development of technologies for recovering metal from metal-rich materials within the framework of remediation projects. Using cost-benefit analysis (CBA), and explicitly taking uncertainties into account, this paper evaluates the potential social profitability of copper recovery as part of four remediation alternatives at a Swedish site. One alternative involves delivery of copper-rich ash to a metal production company for refining. The other three alternatives involve metal leaching from materials and sale of the resulting metal sludge for its further processing at a metal production company using metallurgical methods. All the alternatives are evaluated relative to the conventional excavation and disposal method. Metal recovery from the ash, metal sludge sale, and disposal of the contaminated soil and the ash residue at the local landfill site, was found to be the best remediation alternative. However, given the present conditions, its economic potential is low relative to the conventional excavation and disposal method but higher than direct disposal of the copper-rich ash for refining. Volatile copper prices, the high cost of processing equipment, the highly uncertain cost of the metal leaching and washing process, coupled with the substantial project risks, contribute most to the uncertainties in the CBA results for the alternatives involving metal leaching prior to refining. However, investment in processing equipment within the framework of a long-term investment project, production of safe, reusable soil residue, and higher copper prices on the metal market, can make metal recovery technology socially profitable. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A New Radiofrequency Ablation Procedure to Treat Sacroiliac Joint Pain.

    PubMed

    Cheng, Jianguo; Chen, See Loong; Zimmerman, Nicole; Dalton, Jarrod E; LaSalle, Garret; Rosenquist, Richard

    2016-01-01

    Low back pain may arise from disorders of the sacroiliac joint in up to 30% of patients. Radiofrequency ablation (RFA) of the nerves innervating the sacroiliac joint has been shown to be a safe and efficacious strategy. We aimed to develop a new RFA technique to relieve low back pain secondary to sacroiliac joint disorders. Methodology development with validation through prospective observational non-randomized trial (PONRT). Academic multidisciplinary health care system, Ohio, USA. We devised a guide-block to facilitate accurate placement of multiple electrodes to simultaneously ablate the L5 dorsal ramus and lateral branches of the S1, S2, and S3 dorsal rami. This was achieved by bipolar radiofrequency ablation (b-RFA) to create a strip lesion from the lateral border of the base of the sacral superior articular process (L5-S1 facet joint) to the lateral border of the S3 sacral foramen. We applied this technique in 31 consecutive patients and compared the operating time, x-ray exposure time and dose, and clinical outcomes with patients (n = 62) who have been treated with the cooled radiofrequency technique. Patients' level of pain relief was reported as < 50%, 50 - 80%, and > 80% pain relief at one, 3, 6, and 12 months after the procedure. The relationship between RFA technique and duration of pain relief was evaluated using interval-censored multivariable Cox regression. The new technique allowed reduction of operating time by more than 50%, x-ray exposure time and dose by more than 80%, and cost by more than $1,000 per case. The percent of patients who achieved > 50% pain reduction was significantly higher in the b-RFA group at 3, 6, and 12 months follow-up, compared to the cooled radiofrequency group. No complications were observed in either group. Although the major confounding factors were taken into account in the analysis, use of historical controls does not balance observed and unobserved potential confounding variables between groups so that the reported results are potentially confounded. Compared to the cooled radiofrequency ablation (c-RFA) technique, the new b-RFA technique reduced operating time by more than 50%, decreased x-ray exposure by more than 80%, and cut the cost by more than $1000 per case. The new method was associated with significantly improved clinical outcomes despite the limitations of the study design. Thus this new technique appeared to be safe, efficacious, and cost-effective. Key words: Sacroiliac joint pain, sacroiliac joint, low back pain, radiofrequency ablation (RFA), bipolar radiofrequency ablation (b-RFA), cooled radiofrequency ablation (c-RFA), cost-effectiveness.

  2. IT investments can add business value.

    PubMed

    Williams, Terry G

    2002-05-01

    Investment in information technology (IT) is costly, but necessary to enable healthcare organizations to improve their infrastructure and achieve other improvement initiatives. Such an investment is even more costly, however, if the technology does not appropriately enable organizations to perform business processes that help them accomplish their mission of providing safe, high-quality care cost-effectively. Before committing to a costly IT investment, healthcare organizations should implement a decision-making process that can help them choose, implement, and use technology that will provide sustained business value. A seven-step decision-making process that can help healthcare organizations achieve this result involves performing a gap analysis, assessing and aligning organizational goals, establishing distributed accountability, identifying linked organizational-change initiatives, determining measurement methods, establishing appropriate teams to ensure systems are integrated with multidisciplinary improvement methods, and developing a plan to accelerate adoption of the IT product.

  3. Develop a Low Cost, Safe and Environmentally Benign High Energy and High Rate Reserve Battery

    DTIC Science & Technology

    2004-09-30

    Methylimidazolium hexafluorophosphate BMItrif 1-Butyl-3-Methylimidazolium trifluoromethanesulfonate EC Ethylene carbonate EMC Ethyl methyl carbonate DEC...ionic liquid, a new field in lithium -based batteries, merits special recognition. The contribution of Dr. Mark Salomon with respect to the...applications. In particular, the anode is typically metallic lithium , and the cathode depolarizer is, most commonly, thionyl chloride (SOCl2) or sulfuryl

  4. Empowering Students to Investigate Their Energy Consumption with a Safe, Easy-to-Use, Low-Cost Electrical Energy Meter

    ERIC Educational Resources Information Center

    Darling, Gerald

    2012-01-01

    Middle school students hear about energy continuously: in the news, in many of their classes, and at home. Most students realize that recent wars have been fought over energy resources, and many will accept that overreliance on fossil fuels is changing the global climate. Students understand that as the world population surges past seven billion,…

  5. Laparoscopic Common Bile Duct Exploration Four-Task Training Model: Construct Validity

    PubMed Central

    Otaño, Natalia; Rodríguez, Omaira; Sánchez, Renata; Benítez, Gustavo; Schweitzer, Michael

    2012-01-01

    Background: Training models in laparoscopic surgery allow the surgical team to practice procedures in a safe environment. We have proposed the use of a 4-task, low-cost inert model to practice critical steps of laparoscopic common bile duct exploration. Methods: The performance of 3 groups with different levels of expertise in laparoscopic surgery, novices (A), intermediates (B), and experts (C), was evaluated using a low-cost inert model in the following tasks: (1) intraoperative cholangiography catheter insertion, (2) transcystic exploration, (3) T-tube placement, and (4) choledochoscope management. Kruskal-Wallis and Mann-Whitney tests were used to identify differences among the groups. Results: A total of 14 individuals were evaluated: 5 novices (A), 5 intermediates (B), and 4 experts (C). The results involving intraoperative cholangiography catheter insertion were similar among the 3 groups. As for the other tasks, the expert had better results than the other 2, in which no significant differences occurred. The proposed model is able to discriminate among individuals with different levels of expertise, indicating that the abilities that the model evaluates are relevant in the surgeon's performance in CBD exploration. Conclusions: Construct validity for tasks 2 and 3 was demonstrated. However, task 1 was no capable of distinguishing between groups, and task 4 was not statistically validated. PMID:22906323

  6. Development of new structural health monitoring techniques

    NASA Astrophysics Data System (ADS)

    Fekrmandi, Hadi

    During the past two decades, many researchers have developed methods for the detection of structural defects at the early stages to operate the aerospace vehicles safely and to reduce the operating costs. The Surface Response to Excitation (SuRE) method is one of these approaches developed at FIU to reduce the cost and size of the equipment. The SuRE method excites the surface at a series of frequencies and monitors the propagation characteristics of the generated waves. The amplitude of the waves reaching to any point on the surface varies with frequency; however, it remains consistent as long as the integrity and strain distribution on the part is consistent. These spectral characteristics change when cracks develop or the strain distribution changes. The SHM methods may be used for many applications, from the detection of loose screws to the monitoring of manufacturing operations. A scanning laser vibrometer was used in this study to investigate the characteristics of the spectral changes at different points on the parts. The study started with detecting a load on a plate and estimating its location. The modifications on the part with manufacturing operations were detected and the Part-Based Manufacturing Process Performance Monitoring (PbPPM) method was developed. Hardware was prepared to demonstrate the feasibility of the proposed methods in real time. Using low-cost piezoelectric elements and the non-contact scanning laser vibrometer successfully, the data was collected for the SuRE and PbPPM methods. Locational force, loose bolts and material loss could be easily detected by comparing the spectral characteristics of the arriving waves. On-line methods used fast computational methods for estimating the spectrum and detecting the changing operational conditions from sum of the squares of the variations. Neural networks classified the spectrums when the desktop -- DSP combination was used. The results demonstrated the feasibility of the SuRE and PbPPM methods.

  7. Fluid-driven origami-inspired artificial muscles.

    PubMed

    Li, Shuguang; Vogt, Daniel M; Rus, Daniela; Wood, Robert J

    2017-12-12

    Artificial muscles hold promise for safe and powerful actuation for myriad common machines and robots. However, the design, fabrication, and implementation of artificial muscles are often limited by their material costs, operating principle, scalability, and single-degree-of-freedom contractile actuation motions. Here we propose an architecture for fluid-driven origami-inspired artificial muscles. This concept requires only a compressible skeleton, a flexible skin, and a fluid medium. A mechanical model is developed to explain the interaction of the three components. A fabrication method is introduced to rapidly manufacture low-cost artificial muscles using various materials and at multiple scales. The artificial muscles can be programed to achieve multiaxial motions including contraction, bending, and torsion. These motions can be aggregated into systems with multiple degrees of freedom, which are able to produce controllable motions at different rates. Our artificial muscles can be driven by fluids at negative pressures (relative to ambient). This feature makes actuation safer than most other fluidic artificial muscles that operate with positive pressures. Experiments reveal that these muscles can contract over 90% of their initial lengths, generate stresses of ∼600 kPa, and produce peak power densities over 2 kW/kg-all equal to, or in excess of, natural muscle. This architecture for artificial muscles opens the door to rapid design and low-cost fabrication of actuation systems for numerous applications at multiple scales, ranging from miniature medical devices to wearable robotic exoskeletons to large deployable structures for space exploration. Copyright © 2017 the Author(s). Published by PNAS.

  8. Fluid-driven origami-inspired artificial muscles

    PubMed Central

    Li, Shuguang; Vogt, Daniel M.; Rus, Daniela; Wood, Robert J.

    2017-01-01

    Artificial muscles hold promise for safe and powerful actuation for myriad common machines and robots. However, the design, fabrication, and implementation of artificial muscles are often limited by their material costs, operating principle, scalability, and single-degree-of-freedom contractile actuation motions. Here we propose an architecture for fluid-driven origami-inspired artificial muscles. This concept requires only a compressible skeleton, a flexible skin, and a fluid medium. A mechanical model is developed to explain the interaction of the three components. A fabrication method is introduced to rapidly manufacture low-cost artificial muscles using various materials and at multiple scales. The artificial muscles can be programed to achieve multiaxial motions including contraction, bending, and torsion. These motions can be aggregated into systems with multiple degrees of freedom, which are able to produce controllable motions at different rates. Our artificial muscles can be driven by fluids at negative pressures (relative to ambient). This feature makes actuation safer than most other fluidic artificial muscles that operate with positive pressures. Experiments reveal that these muscles can contract over 90% of their initial lengths, generate stresses of ∼600 kPa, and produce peak power densities over 2 kW/kg—all equal to, or in excess of, natural muscle. This architecture for artificial muscles opens the door to rapid design and low-cost fabrication of actuation systems for numerous applications at multiple scales, ranging from miniature medical devices to wearable robotic exoskeletons to large deployable structures for space exploration. PMID:29180416

  9. Fluid-driven origami-inspired artificial muscles

    NASA Astrophysics Data System (ADS)

    Li, Shuguang; Vogt, Daniel M.; Rus, Daniela; Wood, Robert J.

    2017-12-01

    Artificial muscles hold promise for safe and powerful actuation for myriad common machines and robots. However, the design, fabrication, and implementation of artificial muscles are often limited by their material costs, operating principle, scalability, and single-degree-of-freedom contractile actuation motions. Here we propose an architecture for fluid-driven origami-inspired artificial muscles. This concept requires only a compressible skeleton, a flexible skin, and a fluid medium. A mechanical model is developed to explain the interaction of the three components. A fabrication method is introduced to rapidly manufacture low-cost artificial muscles using various materials and at multiple scales. The artificial muscles can be programed to achieve multiaxial motions including contraction, bending, and torsion. These motions can be aggregated into systems with multiple degrees of freedom, which are able to produce controllable motions at different rates. Our artificial muscles can be driven by fluids at negative pressures (relative to ambient). This feature makes actuation safer than most other fluidic artificial muscles that operate with positive pressures. Experiments reveal that these muscles can contract over 90% of their initial lengths, generate stresses of ˜600 kPa, and produce peak power densities over 2 kW/kg—all equal to, or in excess of, natural muscle. This architecture for artificial muscles opens the door to rapid design and low-cost fabrication of actuation systems for numerous applications at multiple scales, ranging from miniature medical devices to wearable robotic exoskeletons to large deployable structures for space exploration.

  10. A study of methods for lowering aerial environmental survey cost

    NASA Technical Reports Server (NTRS)

    Stansberry, J. R.

    1973-01-01

    The results are presented of a study of methods for lowering the cost of environmental aerial surveys. A wide range of low cost techniques were investigated for possible application to current pressing urban and rural problems. The objective of the study is to establish a definition of the technical problems associated with conducting aerial surveys using various low cost techniques, to conduct a survey of equipment which may be used in low cost systems, and to establish preliminary estimates of cost. A set of candidate systems were selected and described for the environmental survey tasks.

  11. Human Factors for Nursing: From In-Situ Testing to Mobile Usability Engineering.

    PubMed

    Kushniruk, Andre W; Borycki, Elizabeth M; Solvoll, Terje; Hullin, Carola

    2016-01-01

    The tutorial goal is to familiarize participants with human aspects of health informatics and human-centered approaches to the design, evaluation and deployment of both usable and safe healthcare information systems. The focus will be on demonstrating and teaching practical and low-cost methods for evaluating mobile applications in nursing. Basic background to testing methods will be provided, followed by live demonstration of the methods. Then the audience will break into small groups to explore the application of the methods to applications of interest (there will be a number of possible applications that will be available for applications in areas such as electronic health records and decision support, however, if the groups have applications of specific interest to them that will be possible). The challenges of conducting usability testing, and in particular mobile usability testing will be discussed along with practical solutions. The target audience includes practicing nurses and nurse researchers, nursing informatics specialists, nursing students, nursing managers and health informatics professionals interested in improving the usability and safety of healthcare applications.

  12. Airframe Technology Development for Next Generation Launch Vehicles

    NASA Technical Reports Server (NTRS)

    Glass, David E.

    2004-01-01

    The Airframe subproject within NASA's Next Generation Launch Technology (NGLT) program has the responsibility to develop airframe technology for both rocket and airbreathing vehicles for access to space. The Airframe sub-project pushes the state-of-the-art in airframe technology for low-cost, reliable, and safe space transportation. Both low and medium technology readiness level (TRL) activities are being pursued. The key technical areas being addressed include design and integration, hot and integrated structures, cryogenic tanks, and thermal protection systems. Each of the technologies in these areas are discussed in this paper.

  13. The role of radionuclide imaging in the triage of patients with chest pain in the emergency department.

    PubMed

    Abbott, B G; Wackers, F J

    2000-02-01

    The triage of patients presenting to the emergency department with chest pain and a normal or nondiagnostic ECG poses a significant diagnostic challenge to emergency physicians and cardiologists, leading to unnecessary hospital admissions and substantial associated costs. Radionuclide myocardial perfusion imaging can potentially play an important role in this setting, by providing both a safe and efficient means to risk stratify patients with a low-to-moderate likelihood of unstable angina. The proposed algorithm may serve as a strategy to improve utilization of hospital resources while safely identifying the subgroup of patients with acute chest discomfort who do not need to be admitted to the hospital.

  14. Low-cost extrapolation method for maximal LTE radio base station exposure estimation: test and validation.

    PubMed

    Verloock, Leen; Joseph, Wout; Gati, Azeddine; Varsier, Nadège; Flach, Björn; Wiart, Joe; Martens, Luc

    2013-06-01

    An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The method is applicable in situ. It only requires a basic spectrum analyser with appropriate field probes without the need of expensive dedicated LTE decoders. The method is validated both in laboratory and in situ, for a single-input single-output antenna LTE system and a 2×2 multiple-input multiple-output system, with low deviations in comparison with signals measured using dedicated LTE decoders.

  15. Usability and Feasibility of an Internet-Based Virtual Pedestrian Environment to Teach Children to Cross Streets Safely

    PubMed Central

    Schwebel, David C.; McClure, Leslie A.; Severson, Joan

    2013-01-01

    Child pedestrian injury is a preventable global health challenge. Successful training efforts focused on child behavior, including individualized streetside training and training in large virtual pedestrian environments, are laborious and expensive. This study considers the usability and feasibility of a virtual pedestrian environment “game” application to teach children safe street-crossing behavior via the internet, a medium that could be broadly disseminated at low cost. Ten 7- and 8-year-old children participated. They engaged in an internet-based virtual pedestrian environment and completed a brief assessment survey. Researchers rated children's behavior while engaged in the game. Both self-report and researcher observations indicated the internet-based system was readily used by the children without adult support. The youth understood how to engage in the system and used it independently and attentively. The program also was feasible. It provided multiple measures of pedestrian safety that could be used for research or training purposes. Finally, the program was rated by children as engaging and educational. Researcher ratings suggested children used the program with minimal fidgeting or boredom. The pilot test suggests an internet-based virtual pedestrian environment offers a usable, feasible, engaging, and educational environment for child pedestrian safety training. If future research finds children learn the cognitive and perceptual skills needed to cross streets safely within it, internet-based training may provide a low-cost medium to broadly disseminate child pedestrian safety training. The concept may be generalized to other domains of health-related functioning such as teen driving safety, adolescent sexual risk-taking, and adolescent substance use. PMID:24678263

  16. Test results of smart aircraft fastener for KC-135 structural integrity

    NASA Astrophysics Data System (ADS)

    Schoess, Jeffrey N.; Seifert, Greg

    1998-07-01

    Hidden and inaccessible corrosion in aircraft structures is the number one logistics problem for the US Air Force, with an estimated maintenance cost in excess of $LR 1.0B per year in 1990-equivalent dollars. The Smart Aircraft Fastener Evaluation (SAFE) system was developed to provide early warning detection of corrosion-related symptoms in hidden locations of aircraft structures. The SAFE system incorporates an in situ measurement approach that measures and autonomously records several environmental conditions within a Hi-Lok aircraft fastener that could cause corrosion. The SAFE system integrates a miniature electrochemical microsensor array and a time-of-wetness sensor with an ultra low power 8-bit microcontroller and 4- Mbyte solid-state FLASH archival memory to measure evidence of active corrosion. A summary of the technical approach and a detailed analysis of the KC-135 lap joint test coupon results are presented.

  17. Smart fastener for KC-135 structural integrity monitoring

    NASA Astrophysics Data System (ADS)

    Schoess, Jeffrey N.; Seifert, Greg

    1997-06-01

    Hidden and inaccessible corrosion in aircraft structures is the number-one logistics problem for the U.S. Air Force, with an estimated maintenance cost in excess of $DOL1.0 billion per year in 1990-equivalent dollars. The Smart Aircraft Fastener Evaluation (SAFE) system is being developed to provide early warning detection of corrosion- related symptoms in hidden locations of aircraft structures. The SAFE incorporates an in situ measurement approach that measures and autonomously records several environmental conditions (i.e., pH, temperature, chloride, free potential, time-of-wetness) within a Hi-Lok aircraft fastener that could cause corrosion to occur. The SAFE system integrates a miniature electrochemical microsensor array and a time-of- wetness sensor with an ultra-low-power 8-bit microcontroller and 5-Mbyte solid-state FLASH archival memory to measure the evidence of active corrosion. A summary of the technical approach, system design definition, software architecture, and future field test plans will be presented.

  18. Near-Infrared Laser Adjuvant for Influenza Vaccine

    PubMed Central

    Kashiwagi, Satoshi; Yuan, Jianping; Forbes, Benjamin; Hibert, Mathew L.; Lee, Eugene L. Q.; Whicher, Laura; Goudie, Calum; Yang, Yuan; Chen, Tao; Edelblute, Beth; Collette, Brian; Edington, Laurel; Trussler, James; Nezivar, Jean; Leblanc, Pierre; Bronson, Roderick; Tsukada, Kosuke; Suematsu, Makoto; Dover, Jeffrey; Brauns, Timothy; Gelfand, Jeffrey; Poznansky, Mark C.

    2013-01-01

    Safe and effective immunologic adjuvants are often essential for vaccines. However, the choice of adjuvant for licensed vaccines is limited, especially for those that are administered intradermally. We show that non-tissue damaging, near-infrared (NIR) laser light given in short exposures to small areas of skin, without the use of additional chemical or biological agents, significantly increases immune responses to intradermal influenza vaccination without augmenting IgE. The NIR laser-adjuvanted vaccine confers increased protection in a murine influenza lethal challenge model as compared to unadjuvanted vaccine. We show that NIR laser treatment induces the expression of specific chemokines in the skin resulting in recruitment and activation of dendritic cells and is safe to use in both mice and humans. The NIR laser adjuvant technology provides a novel, safe, low-cost, simple-to-use, potentially broadly applicable and clinically feasible approach to enhancing vaccine efficacy as an alternative to chemical and biological adjuvants. PMID:24349390

  19. Efficient Storing Energy Harvested by Triboelectric Nanogenerators Using a Safe and Durable All-Solid-State Sodium-Ion Battery.

    PubMed

    Hou, Huidan; Xu, Qingkai; Pang, Yaokun; Li, Lei; Wang, Jiulin; Zhang, Chi; Sun, Chunwen

    2017-08-01

    Storing energy harvested by triboelectric nanogenerators (TENGs) from ambient mechanical motion is still a great challenge for achieving low-cost and environmental benign power sources. Here, an all-solid-state Na-ion battery with safe and durable performance used for efficient storing pulsed energy harvested by the TENG is demonstrated. The solid-state sodium-ion batteries are charged by galvanostatic mode and pulse mode with the TENG, respectively. The all-solid-state sodium-ion battery displays excellent cyclic performance up to 1000 cycles with a capacity retention of about 85% even at a high charge and discharge current density of 48 mA g -1 . When charged by the TENG, an energy conversion efficiency of 62.3% is demonstrated. The integration of TENGs with the safe and durable all-solid-state sodium-ion batteries is potential for providing more stable power output for self-powered systems.

  20. Development of a biocompatible creatinine-based niosomal delivery system for enhanced oral bioavailability of clarithromycin.

    PubMed

    Ullah, Shafi; Shah, Muhammad Raza; Shoaib, Mohammad; Imran, Muhammad; Elhissi, Abdelbary M A; Ahmad, Farid; Ali, Imdad; Shah, Syed Wadood Ali

    2016-11-01

    Nonionic surfactant vesicles have gained increasing scientific attention for hydrophobic drugs delivery due to their biocompatibility, stability and low cost. The aim of the present study was to synthesize and evaluate a novel creatinine-based nonionic surfactant in terms of its ability to generate biocompatible niosomal system for the delivery of Clarithromycin. The surfactant was synthesized by reacting creatinine with lauroyl chloride followed by characterization using 1 HNMR and MS. The drug-loaded niosomal vesicles of the surfactant were characterized for drug encapsulation efficiency (EE) using LC-MS, vesicle size using dynamic light scattering (DLS) and vesicle shape using atomic force microscopy (AFM). The surfactant was also investigated for blood hemolysis, in vitro cytotoxicity against different cell lines and in vivo acute toxicity in mice. Furthermore, the in vivo bioavailability of Clarithromycin encapsulated in the novel niosomal formulation was investigated using rabbits and quantified through validated LC-MS/MS method. Findings showed that vesicles were able to entrap up to 67.82 ± 1.27% of the drug, and were rounded in shape with a size around 202.73 ± 5.30 nm and low polydispersity. The surfactant caused negligible blood hemolysis, very low cytotoxicity and was found to be safe up to 2500 mg/kg body weight using mice. The niosomal formulation showed twofold enhanced oral bioavailability of Clarithromycin as compared to commercial formulations of the drug. The study has shown that the creatinine-based niosomes developed in our laboratory were biocompatible, safe and increased the oral bioavailability of the model hydrophobic Clarithromycin using experimental animals.

  1. Safety effects of low-cost engineering measures. An observational study in a Portuguese multilane road.

    PubMed

    Vieira Gomes, Sandra; Cardoso, João Lourenço

    2012-09-01

    Single carriageway multilane roads are not, in general, a very safe type of road, mainly because of the high number of seriously injured victims in head-on collisions, when compared with dual carriageway multilane roads, with a median barrier. In this paper the results of a study on the effect of the application of several low cost engineering measures, aimed at road infrastructure correction and road safety improvement on a multilane road (EN6), are presented. The study was developed by the National Laboratory of Civil Engineering (LNEC) for the Portuguese Road Administration and involved a comparison of selected aspects of motorized traffic behaviour (traffic volumes and speeds) measured in several sections of EN6, as well as monitoring of road safety developments in the same road. The applied low cost engineering measures allowed a reduction of 10% in the expected annual number of personal injury accidents and a 70% decrease in the expected annual number of head-on collisions; the expected annual frequency of accidents involving killed and seriously injured persons was reduced by 26%. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Recent Enhancements to the National Transonic Facility (Mixed Mode Operations)

    NASA Technical Reports Server (NTRS)

    Kilgore, W. Allen; Chan, David; Balakrishna, S.; Wahls, Richard A.

    2006-01-01

    The U.S. National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the development of a Mixed-mode of operations that combine Air-mode operations with Nitrogen-mode operations. This implementation and operational results of this new Mixed-mode expands the ambient temperature transonic region of testing beyond the Air-mode limitations at a significantly reduced cost over Nitrogen Mode operation.

  3. Agile Development Methods for Space Operations

    NASA Technical Reports Server (NTRS)

    Trimble, Jay; Webster, Chris

    2012-01-01

    Main stream industry software development practice has gone from a traditional waterfall process to agile iterative development that allows for fast response to customer inputs and produces higher quality software at lower cost. How can we, the space ops community, adopt state of the art software development practice, achieve greater productivity at lower cost, and maintain safe and effective space flight operations? At NASA Ames, we are developing Mission Control Technologies Software, in collaboration with Johnson Space Center (JSC) and, more recently, the Jet Propulsion Laboratory (JPL).

  4. Paper-basd surface enhanced Raman spectroscopy of pnenobarbital sodium for point-of-care therapeutic drug monitoring

    NASA Astrophysics Data System (ADS)

    Yokoyama, Moe; Yamada, Kenji; Nishimura, Takahiro; Kido, Michiko; Jeong, Hieyong; Ohno, Yuko

    2015-03-01

    Therapeutic drug monitoring (TDM) contributes to safe and effective pharmacotherapy in clinical fields. A simple, rapid, low-cost, and minimally-invasive drug measurement method attracts much interest for point-of-care TDM. Tear fluids can be collected minimally-invasively compared to blood sampling and there is a correlation between a drug concentration in tears and that in bloods. Surface enhanced Raman spectroscopy (SERS) with paper-based substrate is useful for point-of-care TDM owing to inexpensiveness and high-sensitivity. Paper is also a safe tear collection tool. Then we are studying on a paper-based SERS of tear specimen for point-of-care TDM. In this paper, to improve sensitivity in measuring drug concentration in tear fluids, we fabricated a SERS substrate by coating gold nano-rods on a paper substrate and evaluated whether the fabricated substrate can enhance Raman scattering. Sodium phenobarbital (PB), an anti-convulsant agent, was used as a target. In experiment, the fabricated substrate indicated the lower detection limit of PB in a solution than a plain paper substrate. This result showed the potential of the paper based SERS substrate to measure drug concentration in tears simply and inexpensively.

  5. Safe Sleep Practices of Kansas Birthing Hospitals

    PubMed Central

    Ahlers-Schmidt, Carolyn R.; Schunn, Christy; Sage, Cherie; Engel, Matthew; Benton, Mary

    2018-01-01

    Background Sleep-related death is tied with congenital anomalies as the leading cause of infant mortality in Kansas, and external risk factors are present in 83% of these deaths. Hospitals can impact caregiver intentions to follow risk-reduction strategies. This project assessed the current practices and policies of Kansas hospitals with regard to safe sleep. Methods A cross-sectional survey of existing safe sleep practices and policies in Kansas hospitals was performed. Hospitals were categorized based on reported delivery volume and data were compared across hospital sizes. Results Thirty-one of 73 (42%) contacted hospitals responded. Individual survey respondents represented various hospital departments including newborn/well-baby (68%), neonatal intensive care unit (3%) and other non-nursery departments or administration (29%). Fifty-eight percent of respondents reported staff were trained on infant safe sleep; 44% of these held trainings annually. High volume hospitals tended to have more annual training than low or mid volume birth hospitals. Thirty-nine percent reported a safe sleep policy, though most of these (67%) reported never auditing compliance. The top barrier to safe sleep education, regardless of delivery volume, was conflicting patient and family member beliefs. Conclusions Hospital promotion of infant safe sleep is being conducted in Kansas to varying degrees. High and mid volume birth hospitals may need to work more on formal auditing of safe sleep practices, while low volume hospitals may need more staff training. Low volume hospitals also may benefit from access to additional caregiver education materials. Finally, it is important to note hospitals should not be solely responsible for safe sleep education. PMID:29844848

  6. Responding to Climate Change at the Poles: Findings from the National Research Council's Reports on Climate Intervention

    NASA Astrophysics Data System (ADS)

    Russell, L. M.; McNutt, M. K.; Abdalati, W.; Caldeira, K.; Doney, S. C.; Falkowski, P. G.; Fetter, S.; Fleming, J. R.; Hamburg, S.; Morgan, G.; Penner, J.; Pierrehumbert, R.; Rasch, P. J.; Snow, J. T.; Wilcox, J.

    2015-12-01

    Earlier this year the National Research Council of the US National Academy of Sciences released a pair of reports on two strategies of climate intervention in order to reduce the risks of negative impacts from climate change. The first of the pair of reports discusses the opportunities and challenges in carbon capture and long-term, safe sequestration. The second report discusses several approaches to reflecting sunlight to cool Earth, including the risks, time scales, costs, and socio-economic, and political considerations. The primary conclusion from these pair of reports is that mitigation and adaptation are still our best choices in terms of cost and low risk for reducing harmful effects from climate change: there is no "silver bullet." Given that the polar regions of the planet are the most sensitive to climate change, the reports also touched on the potential for regional climate intervention. The majority of the methods that are currently under discussion and for which there is a body of peer-reviewed research would have global impacts, with but few exceptions.

  7. Negative predictive value and potential cost savings of acute nuclear myocardial perfusion imaging in low risk patients with suspected acute coronary syndrome: A prospective single blinded study

    PubMed Central

    Forberg, Jakob L; Hilmersson, Catarina E; Carlsson, Marcus; Arheden, Håkan; Björk, Jonas; Hjalte, Krister; Ekelund, Ulf

    2009-01-01

    Background Previous studies from the USA have shown that acute nuclear myocardial perfusion imaging (MPI) in low risk emergency department (ED) patients with suspected acute coronary syndrome (ACS) can be of clinical value. The aim of this study was to evaluate the utility and hospital economics of acute MPI in Swedish ED patients with suspected ACS. Methods We included 40 patients (mean age 55 ± 2 years, 50% women) who were admitted from the ED at Lund University Hospital for chest pain suspicious of ACS, and who had a normal or non-ischemic ECG and no previous myocardial infarction. All patients underwent MPI from the ED, and the results were analyzed only after patient discharge. The current diagnostic practice of admitting the included patients for observation and further evaluation was compared to a theoretical "MPI strategy", where patients with a normal MPI test would have been discharged home from the ED. Results Twenty-seven patients had normal MPI results, and none of them had ACS. MPI thus had a negative predictive value for ACS of 100%. With the MPI strategy, 2/3 of the patients would thus have been discharged from the ED, resulting in a reduction of total hospital cost by some 270 EUR and of bed occupancy by 0.8 days per investigated patient. Conclusion Our findings in a Swedish ED support the results of larger American trials that acute MPI has the potential to safely reduce the number of admissions and decrease overall costs for low-risk ED patients with suspected ACS. PMID:19545365

  8. Estimating dietary costs of low-income women in California: a comparison of 2 approaches.

    PubMed

    Aaron, Grant J; Keim, Nancy L; Drewnowski, Adam; Townsend, Marilyn S

    2013-04-01

    Currently, no simplified approach to estimating food costs exists for a large, nationally representative sample. The objective was to compare 2 approaches for estimating individual daily diet costs in a population of low-income women in California. Cost estimates based on time-intensive method 1 (three 24-h recalls and associated food prices on receipts) were compared with estimates made by using less intensive method 2 [a food-frequency questionnaire (FFQ) and store prices]. Low-income participants (n = 121) of USDA nutrition programs were recruited. Mean daily diet costs, both unadjusted and adjusted for energy, were compared by using Pearson correlation coefficients and the Bland-Altman 95% limits of agreement between methods. Energy and nutrient intakes derived by the 2 methods were comparable; where differences occurred, the FFQ (method 2) provided higher nutrient values than did the 24-h recall (method 1). The crude daily diet cost was $6.32 by the 24-h recall method and $5.93 by the FFQ method (P = 0.221). The energy-adjusted diet cost was $6.65 by the 24-h recall method and $5.98 by the FFQ method (P < 0.001). Although the agreement between methods was weaker than expected, both approaches may be useful. Additional research is needed to further refine a large national survey approach (method 2) to estimate daily dietary costs with the use of this minimal time-intensive method for the participant and moderate time-intensive method for the researcher.

  9. Reinventing Batteries for Grid Storage

    ScienceCinema

    Banerjee, Sanjoy

    2017-12-09

    The City University of New York's Energy Institute, with the help of ARPA-E funding, is creating safe, low cost, rechargeable, long lifecycle batteries that could be used as modular distributed storage for the electrical grid. The batteries could be used at the building level or the utility level to offer benefits such as capture of renewable energy, peak shaving and microgridding, for a safer, cheaper, and more secure electrical grid.

  10. Can real time location system technology (RTLS) provide useful estimates of time use by nursing personnel?

    PubMed

    Jones, Terry L; Schlegel, Cara

    2014-02-01

    Accurate, precise, unbiased, reliable, and cost-effective estimates of nursing time use are needed to insure safe staffing levels. Direct observation of nurses is costly, and conventional surrogate measures have limitations. To test the potential of electronic capture of time and motion through real time location systems (RTLS), a pilot study was conducted to assess efficacy (method agreement) of RTLS time use; inter-rater reliability of RTLS time-use estimates; and associated costs. Method agreement was high (mean absolute difference = 28 seconds); inter-rater reliability was high (ICC = 0.81-0.95; mean absolute difference = 2 seconds); and costs for obtaining RTLS time-use estimates on a single nursing unit exceeded $25,000. Continued experimentation with RTLS to obtain time-use estimates for nursing staff is warranted. © 2013 Wiley Periodicals, Inc.

  11. Background Error Covariance Estimation using Information from a Single Model Trajectory with Application to Ocean Data Assimilation into the GEOS-5 Coupled Model

    NASA Technical Reports Server (NTRS)

    Keppenne, Christian L.; Rienecker, Michele M.; Kovach, Robin M.; Vernieres, Guillaume; Koster, Randal D. (Editor)

    2014-01-01

    An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory. SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.

  12. Background Error Covariance Estimation Using Information from a Single Model Trajectory with Application to Ocean Data Assimilation

    NASA Technical Reports Server (NTRS)

    Keppenne, Christian L.; Rienecker, Michele; Kovach, Robin M.; Vernieres, Guillaume

    2014-01-01

    An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory.SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.

  13. Synthesis of Cu2ZnSnS4 thin films by a precursor solution paste for thin film solar cell applications.

    PubMed

    Cho, Jin Woo; Ismail, Agus; Park, Se Jin; Kim, Woong; Yoon, Sungho; Min, Byoung Koun

    2013-05-22

    Cu2ZnSnS4 (CZTS) is a very promising semiconductor material when used for the absorber layer of thin film solar cells because it consists of only abundant and inexpensive elements. In addition, a low-cost solution process is applicable to the preparation of CZTS absorber films, which reduces the cost when this film is used for the production of thin film solar cells. To fabricate solution-processed CZTS thin film using an easily scalable and relatively safe method, we suggest a precursor solution paste coating method with a two-step heating process (oxidation and sulfurization). The synthesized CZTS film was observed to be composed of grains of a size of ~300 nm, showing an overall densely packed morphology with some pores and voids. A solar cell device with this film as an absorber layer showed the highest efficiency of 3.02% with an open circuit voltage of 556 mV, a short current density of 13.5 mA/cm(2), and a fill factor of 40.3%. We also noted the existence of Cd moieties and an inhomogeneous Zn distribution in the CZTS film, which may have been triggered by the presence of pores and voids in the CZTS film.

  14. Advanced-to-Revolutionary Space Technology Options - The Responsibly Imaginable

    NASA Technical Reports Server (NTRS)

    Bushnell, Dennis M.

    2013-01-01

    Paper summarizes a spectrum of low TRL, high risk technologies and systems approaches which could massively change the cost and safety of space exploration/exploitation/industrialization. These technologies and approaches could be studied in a triage fashion, the method of evaluation wherein several prospective solutions are investigated in parallel to address the innate risk of each, with resources concentrated on the more successful as more is learned. Technology areas addressed include Fabrication, Materials, Energetics, Communications, Propulsion, Radiation Protection, ISRU and LEO access. Overall and conceptually it should be possible with serious research to enable human space exploration beyond LEO both safe and affordable with a design process having sizable positive margins. Revolutionary goals require, generally, revolutionary technologies. By far, Revolutionary Energetics is the most important, has the most leverage, of any advanced technology for space exploration applications.

  15. The usefulness and costs of routine contrast studies after laparoscopic sleeve gastrectomy for detecting staple line leaks

    PubMed Central

    Terterov, Dimitry; Leung, Philemon Ho-Yan; Twells, Laurie K.; Gregory, Deborah M.; Smith, Chris; Boone, Darrell; Pace, David

    2017-01-01

    Background Although laparoscopic sleeve gastrectomy (LSG) has been shown to be a safe and effective treatment for severe obesity (body mass index ≥ 35), staple line leaks remain a major complication and account for a substantial portion of the procedure’s morbidity and mortality. Many centres performing LSG routinely obtain contrast studies on postoperative day 1 for early detection of staple line leaks. We examined the usefulness of Gastrografin swallow as an early detection test for staple line leaks on postoperative day 1 after LSG as well as the associated costs. Methods We conducted a retrospective review of a prospectively collected database that included 200 patients who underwent LSG for severe obesity between 2011 and 2014. Primary outcome measures were the incidence of staple line leaks and the results of Gastrografin swallow tests. We obtained imaging costs from appropriate hospital departments. Results Gastrografin swallow was obtained on postoperative day 1 for all 200 patients who underwent LSG. Three patients (1.5%) were found to have staple line leaks. Gastrograffin swallows yielded 1 true positive result and 2 false negatives. The false negatives were subsequently diagnosed on computed tomography (CT) scan. The sensitivity of Gastrografin swallow in this study was 33%. For 200 patients, the total direct cost of the Gastrografin swallows was $35 000. Conclusion The use of routine upper gastrointestinal contrast studies for early detection of staple line leaks has low sensitivity and is costly. We recommend selective use of CT instead. PMID:28742012

  16. Low cost high efficiency GaAs monolithic RF module for SARSAT distress beacons

    NASA Technical Reports Server (NTRS)

    Petersen, W. C.; Siu, D. P.; Cook, H. F.

    1991-01-01

    Low cost high performance (5 Watts output) 406 MHz beacons are urgently needed to realize the maximum utilization of the Search and Rescue Satellite-Aided Tracking (SARSAT) system spearheaded in the U.S. by NASA. Although current technology can produce beacons meeting the output power requirement, power consumption is high due to the low efficiency of available transmitters. Field performance is currently unsatisfactory due to the lack of safe and reliable high density batteries capable of operation at -40 C. Low cost production is also a crucial but elusive requirement for the ultimate wide scale utilization of this system. Microwave Monolithics Incorporated (MMInc.) has proposed to make both the technical and cost goals for the SARSAT beacon attainable by developing a monolithic GaAs chip set for the RF module. This chip set consists of a high efficiency power amplifier and a bi-phase modulator. In addition to implementing the RF module in Monolithic Microwave Integrated Circuit (MMIC) form to minimize ultimate production costs, the power amplifier has a power-added efficiency nearly twice that attained with current commercial technology. A distress beacon built using this RF module chip set will be significantly smaller in size and lighter in weight due to a smaller battery requirement, since the 406 MHz signal source and the digital controller have far lower power consumption compared to the 5 watt power amplifier. All the program tasks have been successfully completed. The GaAs MMIC RF module chip set has been designed to be compatible with the present 406 MHz signal source and digital controller. A complete high performance low cost SARSAT beacon can be realized with only additional minor iteration and systems integration.

  17. Financing blood transfusion services in sub-Saharan Africa: a role for user fees?

    PubMed

    Hensher, M; Jefferys, E

    2000-09-01

    The provision of a secure and safe blood supply has taken on new importance in sub-Saharan Africa with the onset of the AIDS epidemic. Blood transfusion services capable of providing safe blood are not cheap, however, and there has been some debate on the desirability and sustainability of different financing mechanisms for blood transfusion services. This paper examines patterns of financing blood transfusion in three countries--Côte d'Ivoire, Zimbabwe and Mozambique. It goes on to consider the conceptual options for financing safe blood, and to examine in detail the possible role of user fees for blood transfusion in Africa, developing a simple model of their likely burden to patients based on data from Côte d'Ivoire. The model indicates that, at best, there can only be a limited role for user fees in the financing of safe blood transfusion services, due mainly to the relatively high cost of producing a unit of safe blood. Charging individuals for the blood they receive is likely to be administratively complex and costly, could realistically recover only a fraction of the production costs involved, and is further complicated by the fact that the main recipients of blood transfusion in sub-Saharan Africa are children and pregnant women. If cost-recovery for safe blood is to be attempted, the most viable option appears to be that of charging a collective fee, levied upon all inpatients, not just on those who receive blood. Such a mechanism is not without problems, not least in its failure to offer incentives for more appropriate blood use, and it is still likely to recover only a portion of the costs of producing safe blood. Whether or not cost-recovery is instituted, there will remain an important role for public funding of blood transfusion services, and, by implication, an important role for foreign donor support.

  18. Study of the Staebler-Wronski degradation effect in a-Si:H based p-i-n solar cell

    NASA Technical Reports Server (NTRS)

    Naseem, H. A.; Brown, W. D.; Ang, S. S.

    1993-01-01

    Conversion of solar energy into electricity using environmentally safe and clean photovoltaic methods to supplement the ever increasing energy needs has been a cherished goal of many scientists and engineers around the world. Photovoltaic solar cells on the other hand, have been the power source for satellites ever since their introduction in the early sixties. For widespread terrestrial applications, however, the cost of photovoltaic systems must be reduced considerably. Much progress has been made in the recent past towards developing economically viable terrestrial systems, and the future looks highly promising. Thin film solar cells offer cost reductions mainly from their low processing cost, low material cost, and choice of low cost substrates. These are also very attractive for space applications because of their high power densities (power produced per kilogram of solar cell pay load) and high radiation resistance. Amorphous silicon based solar cells are amongst the top candidates for economically viable terrestrial and space based power generation. Despite very low federal funding during the eighties, amorphous silicon solar cell efficiencies have continually been improved - from a low 3 percent to over 13 percent now. Further improvements have been made by the use of multi-junction tandem solar cells. Efficiencies close to 15 percent have been achieved in several labs. In order to be competitive with fossil fuel generated electricity, it is believed that module efficiency of 15 percent or cell efficiency of 20 percent is required. Thus, further improvements in cell performance is imperative. One major problem that was discovered almost 15 years ago in amorphous silicon devices is the well known Staebler-Wronski Effect. Efficiency of amorphous silicon solar cells was found to degrade upon exposure to sunlight. Until now their is no consensus among the scientists on the mechanism for this degradation. Efficiency may degrade anywhere from 10 percent to almost 50 percent within the first few months of operation. In order to improve solar cell efficiencies, it is clear that the cause or causes of such degradation must be found and the processing conditions altered to minimize the loss in efficiency. This project was initiated in 1987 to investigate a possible link between metallic impurities, in particular, Ag, and this degradation. Such a link was established by one of the NASA scientists for the light induced degradation of n+/p crystalline silicon solar cells.

  19. Regulating transgenic crops sensibly: lessons from plant breeding, biotechnology and genomics.

    PubMed

    Bradford, Kent J; Van Deynze, Allen; Gutterson, Neal; Parrott, Wayne; Strauss, Steven H

    2005-04-01

    The costs of meeting regulatory requirements and market restrictions guided by regulatory criteria are substantial impediments to the commercialization of transgenic crops. Although a cautious approach may have been prudent initially, we argue that some regulatory requirements can now be modified to reduce costs and uncertainty without compromising safety. Long-accepted plant breeding methods for incorporating new diversity into crop varieties, experience from two decades of research on and commercialization of transgenic crops, and expanding knowledge of plant genome structure and dynamics all indicate that if a gene or trait is safe, the genetic engineering process itself presents little potential for unexpected consequences that would not be identified or eliminated in the variety development process before commercialization. We propose that as in conventional breeding, regulatory emphasis should be on phenotypic rather than genomic characteristics once a gene or trait has been shown to be safe.

  20. Novel low-cost thermotherapy for cutaneous leishmaniasis in Peru.

    PubMed

    Valencia, Braulio M; Miller, David; Witzig, Richard S; Boggild, Andrea K; Llanos-Cuentas, Alejandro

    2013-01-01

    Thermotherapy is an accepted alternative therapy for new-world cutaneous leishmaniasis, but current heat-delivery modalities are too costly to be made widely available to endemic populations. We adapted a low-cost heat pack named the HECT-CL device that delivers safe, reliable, and renewable conduction heat. 25 patients with cutaneous leishmaniasis completed treatment with the device at an initial temperature of 52°C ± 2°C for 3 minutes to each lesion, repeated daily for 7 days, and were followed up for 6 months by direct observation. The overall definitive clinical cure rate was 60%. Concurrently, 13 patients meeting minimally significant exclusion criteria received identical compassionate use treatment with a cumulative definitive cure rate of 68.4%, 75% for those who had experienced CL relapse after prior antimonial treatment. Therapy was well tolerated. Reversible second-degree burns occurred in two patients and no bacterial super-infections were observed. HECT-CL is a promising treatment and deserves further study to verify its safety and efficacy as adjuvant and mono- therapy.

  1. Novel Low-Cost Thermotherapy for Cutaneous Leishmaniasis in Peru

    PubMed Central

    Witzig, Richard S.; Boggild, Andrea K.; Llanos-Cuentas, Alejandro

    2013-01-01

    Thermotherapy is an accepted alternative therapy for new-world cutaneous leishmaniasis, but current heat-delivery modalities are too costly to be made widely available to endemic populations. We adapted a low-cost heat pack named the HECT-CL device that delivers safe, reliable, and renewable conduction heat. 25 patients with cutaneous leishmaniasis completed treatment with the device at an initial temperature of 52°C±2°C for 3 minutes to each lesion, repeated daily for 7 days, and were followed up for 6 months by direct observation. The overall definitive clinical cure rate was 60%. Concurrently, 13 patients meeting minimally significant exclusion criteria received identical compassionate use treatment with a cumulative definitive cure rate of 68.4%, 75% for those who had experienced CL relapse after prior antimonial treatment. Therapy was well tolerated. Reversible second-degree burns occurred in two patients and no bacterial super-infections were observed. HECT-CL is a promising treatment and deserves further study to verify its safety and efficacy as adjuvant and mono- therapy. PMID:23658851

  2. Current Advances in Detection and Treatment of Babesiosis

    PubMed Central

    Mosqueda, J; Olvera-Ramírez, A; Aguilar-Tipacamú, G; Cantó, GJ

    2012-01-01

    Babesiosis is a disease with a world-wide distribution affecting many species of mammals principally cattle and man. The major impact occurs in the cattle industry where bovine babesiosis has had a huge economic effect due to loss of meat and beef production of infected animals and death. Nowadays to those costs there must be added the high cost of tick control, disease detection, prevention and treatment. In almost a century and a quarter since the first report of the disease, the truth is: there is no a safe and efficient vaccine available, there are limited chemotherapeutic choices and few low-cost, reliable and fast detection methods. Detection and treatment of babesiosis are important tools to control babesiosis. Microscopy detection methods are still the cheapest and fastest methods used to identify Babesia parasites although their sensitivity and specificity are limited. Newer immunological methods are being developed and they offer faster, more sensitive and more specific options to conventional methods, although the direct immunological diagnoses of parasite antigens in host tissues are still missing. Detection methods based on nucleic acid identification and their amplification are the most sensitive and reliable techniques available today; importantly, most of those methodologies were developed before the genomics and bioinformatics era, which leaves ample room for optimization. For years, babesiosis treatment has been based on the use of very few drugs like imidocarb or diminazene aceturate. Recently, several pharmacological compounds were developed and evaluated, offering new options to control the disease. With the complete sequence of the Babesia bovis genome and the B. bigemina genome project in progress, the post-genomic era brings a new light on the development of diagnosis methods and new chemotherapy targets. In this review, we will present the current advances in detection and treatment of babesiosis in cattle and other animals, with additional reference to several apicomplexan parasites. PMID:22360483

  3. [Percutaneous tracheotomy].

    PubMed

    Paleczny, J; Maciejewski, D; Łoniewska-Paleczny, E; Sawczuk, M; Kaczur, A

    2000-01-01

    The purpose of this study was to compare on the basis of up to date papers currently applied methods of the percutaneous tracheostomy (PT). There are four main PT methods by: Ciaglia, Schachner, Griggs and Fantoni. In these methods a wire is introduced into the trachea serving as a guide for special forceps or series of dilatators of increasing diameter to dilate the wall and allow cannulation of the trachea. In the literature authors found a low incidence of complications after PT. Acute complications were documented in 6-18% and late complications in 1-3% of the patients. Follow-up showed no late obstructive complications at the level of stomia and very low (0.3-0.36%) mortality risk. Translaryngeal tracheostomy (TLT) by Fantoni ensures minimal risk of complications and tissue trauma. In the TLT method through a needle inserted in to the trachea a guide wire is retrogradely pushed out of the mouth and attached to special flexible tracheostomy tube by flexible plastic cone with pointed metal tip. This device is then pulled back through larynx and outwards across the trachea and neck wall by traction on the wire. TLT can also be used in infants and children and in difficult patients in whom other techniques are riskier Review of the literature suggests that the PT can be safe and also cost-effective for properly selected patients in intensive care and other hospital units.

  4. New frontiers for health information systems using Epi Info in developing countries: structured application framework for Epi Info (SAFE).

    PubMed

    Ma, J; Otten, M; Kamadjeu, R; Mir, R; Rosencrans, L; McLaughlin, S; Yoon, S

    2008-04-01

    For more than two decades, Epi Info software has been used to meet the data management, analysis, and mapping needs of public health professionals in more than 181 countries and 13 languages. Until now, most Epi Info systems have been relatively simple, mainly because of a lack of detailed and structured guidance for developing complex systems. We created the structured application framework for Epi Info (SAFE), which is a set of guidelines that allows developers to create both simple and complex information systems using accepted good programming practices. This has resulted in application code blocks that are re-useable and easy to maintain, modify, and enhance. The flexibility of SAFE allows various aggregate and case-based application modules to be rapidly created, combined, and updated to create health information systems or sub-systems enabling continuous, incremental enhancement as national and local capacity increases. SAFE and Epi Info are both cost-free and have low system requirements--characteristics that render this framework and software beneficial for developing countries.

  5. Feasibility of Space Disposal of Radioactive Nuclear Waste. 1: Executive Summary

    NASA Technical Reports Server (NTRS)

    1973-01-01

    This NASA study, performed at the request of the AEC, concludes that transporting radioactive waste (primarily long-lived isotopes) into space is feasible. Tentative solutions are presented for technical problems involving safe packaging. Launch systems (existing and planned), trajectories, potential hazards, and various destinations were evaluated. Solar system escape is possible and would have the advantage of ultimate removal of the radioactive waste from man's environment. Transportation costs would be low (comparable to less than a 5 percent increase in the cost of electricity) even though more than 100 space shuttle launches per year would be required by the year 2000.

  6. Evolution of corundum-structured III-oxide semiconductors: Growth, properties, and devices

    NASA Astrophysics Data System (ADS)

    Fujita, Shizuo; Oda, Masaya; Kaneko, Kentaro; Hitora, Toshimi

    2016-12-01

    The recent progress and development of corundum-structured III-oxide semiconductors are reviewed. They allow bandgap engineering from 3.7 to ∼9 eV and function engineering, leading to highly durable electronic devices and deep ultraviolet optical devices as well as multifunctional devices. Mist chemical vapor deposition can be a simple and safe growth technology and is advantageous for reducing energy and cost for the growth. This is favorable for the wide commercial use of devices at low cost. The III-oxide semiconductors are promising candidates for new devices contributing to sustainable social, economic, and technological development for the future.

  7. Potential low cost, safe, high efficiency propellant for future space program

    NASA Astrophysics Data System (ADS)

    Zhou, D.

    2005-03-01

    Mixtures of nanometer or micrometer sized carbon powder suspended in hydrogen and methane/hydrogen mixtures are proposed as candidates for low cost, high efficiency propellants for future space programs. While liquid hydrogen has low weight and high heat of combustion per unit mass, because of the low mass density the heat of combustion per unit volume is low, and the liquid hydrogen storage container must be large. The proposed propellants can produce higher gross heat combustion with small volume with trade off of some weight increase. Liquid hydrogen can serve as the fluid component of the propellant in the mixtures and thus used by current rocket engine designs. For example, for the same volume a mixture of 5% methane and 95% hydrogen, can lead to an increase in the gross heat of combustion by about 10% and an increase in the Isp (specific impulse) by 21% compared to a pure liquid hydrogen propellant. At liquid hydrogen temperatures of 20.3 K, methane will be in solid state, and must be formed as fine granules (or slush) to satisfy the requirement of liquid propellant engines.

  8. Microbiological effectiveness and cost of boiling to disinfect drinking water in rural Vietnam.

    PubMed

    Clasen, Thomas F; Thao, Do Hoang; Boisson, Sophie; Shipin, Oleg

    2008-06-15

    Despite certain shortcomings, boiling is still the most common means of treating water in the home and the benchmark against which alternative household-based disinfection and filtration methods must be measured. We assessed the microbiological effectiveness and cost of boiling among a vulnerable population relying on unimproved water sources and commonly practicing boiling as a means of disinfecting water. In a 12 week study among 50 households from a rural community in Vietnam, boiling was associated with a 97% reduction in geometric mean thermotolerant coliforms (TTCs) (p < 0.001). Despite high levels of faecal contamination in source water, 37% of stored water samples from self-reported boilers met the WHO standard for safe drinking water (0 TTC/100 mL), and 38.3% fell within the low risk category (1--10 TTC/100 mL). Nevertheless, 60.5% of stored drinking water samples were positive for TTC, with 22.2% falling into the medium risk category (11--100 TTC/100 mL). The estimated cost of wood used to boil water was US$ 0.272 per month for wood collectors and US$ 1.68 per month for wood purchasers, representing approximately 0.48% to 1.04%, respectively, of the average monthly income of participating households.

  9. Adaptive Inner-Loop Rover Control

    NASA Technical Reports Server (NTRS)

    Kulkarni, Nilesh; Ippolito, Corey; Krishnakumar, Kalmanje; Al-Ali, Khalid M.

    2006-01-01

    Adaptive control technology is developed for the inner-loop speed and steering control of the MAX Rover. MAX, a CMU developed rover, is a compact low-cost 4-wheel drive, 4-wheel steer (double Ackerman), high-clearance agile durable chassis, outfitted with sensors and electronics that make it ideally suited for supporting research relevant to intelligent teleoperation and as a low-cost autonomous robotic test bed and appliance. The design consists of a feedback linearization based controller with a proportional - integral (PI) feedback that is augmented by an online adaptive neural network. The adaptation law has guaranteed stability properties for safe operation. The control design is retrofit in nature so that it fits inside the outer-loop path planning algorithms. Successful hardware implementation of the controller is illustrated for several scenarios consisting of actuator failures and modeling errors in the nominal design.

  10. Estimating dietary costs of low-income women in California: a comparison of 2 approaches123

    PubMed Central

    Aaron, Grant J; Keim, Nancy L; Drewnowski, Adam

    2013-01-01

    Background: Currently, no simplified approach to estimating food costs exists for a large, nationally representative sample. Objective: The objective was to compare 2 approaches for estimating individual daily diet costs in a population of low-income women in California. Design: Cost estimates based on time-intensive method 1 (three 24-h recalls and associated food prices on receipts) were compared with estimates made by using less intensive method 2 [a food-frequency questionnaire (FFQ) and store prices]. Low-income participants (n = 121) of USDA nutrition programs were recruited. Mean daily diet costs, both unadjusted and adjusted for energy, were compared by using Pearson correlation coefficients and the Bland-Altman 95% limits of agreement between methods. Results: Energy and nutrient intakes derived by the 2 methods were comparable; where differences occurred, the FFQ (method 2) provided higher nutrient values than did the 24-h recall (method 1). The crude daily diet cost was $6.32 by the 24-h recall method and $5.93 by the FFQ method (P = 0.221). The energy-adjusted diet cost was $6.65 by the 24-h recall method and $5.98 by the FFQ method (P < 0.001). Conclusions: Although the agreement between methods was weaker than expected, both approaches may be useful. Additional research is needed to further refine a large national survey approach (method 2) to estimate daily dietary costs with the use of this minimal time-intensive method for the participant and moderate time-intensive method for the researcher. PMID:23388658

  11. Testing of low-risk patients presenting to the emergency department with chest pain: a scientific statement from the American Heart Association.

    PubMed

    Amsterdam, Ezra A; Kirk, J Douglas; Bluemke, David A; Diercks, Deborah; Farkouh, Michael E; Garvey, J Lee; Kontos, Michael C; McCord, James; Miller, Todd D; Morise, Anthony; Newby, L Kristin; Ruberg, Frederick L; Scordo, Kristine Anne; Thompson, Paul D

    2010-10-26

    The management of low-risk patients presenting to emergency departments is a common and challenging clinical problem entailing 8 million emergency department visits annually. Although a majority of these patients do not have a life-threatening condition, the clinician must distinguish between those who require urgent treatment of a serious problem and those with more benign entities who do not require admission. Inadvertent discharge of patients with acute coronary syndrome from the emergency department is associated with increased mortality and liability, whereas inappropriate admission of patients without serious disease is neither indicated nor cost-effective. Clinical judgment and basic clinical tools (history, physical examination, and electrocardiogram) remain primary in meeting this challenge and affording early identification of low-risk patients with chest pain. Additionally, established and newer diagnostic methods have extended clinicians' diagnostic capacity in this setting. Low-risk patients presenting with chest pain are increasingly managed in chest pain units in which accelerated diagnostic protocols are performed, comprising serial electrocardiograms and cardiac injury markers to exclude acute coronary syndrome. Patients with negative findings usually complete the accelerated diagnostic protocol with a confirmatory test to exclude ischemia. This is typically an exercise treadmill test or a cardiac imaging study if the exercise treadmill test is not applicable. Rest myocardial perfusion imaging has assumed an important role in this setting. Computed tomography coronary angiography has also shown promise in this setting. A negative accelerated diagnostic protocol evaluation allows discharge, whereas patients with positive findings are admitted. This approach has been found to be safe, accurate, and cost-effective in low-risk patients presenting with chest pain.

  12. Groundwater Exploration for Rural Communities in Ghana, West Africa

    NASA Astrophysics Data System (ADS)

    McKay, W. A.

    2001-05-01

    Exploration for potable water in developing countries continues to be a major activity, as there are more than one billion people without access to safe drinking water. Exploration for groundwater becomes more critical in regions where groundwater movement and occurrence is controlled by secondary features such as fractures and faults. Drilling success rates in such geological settings are generally very low, but can be improved by integrating geological, hydrogeological, aerial photo interpretation with land-based geophysical technology in the selection of drilling sites. To help alleviate water supply problems in West Africa, the Conrad N. Hilton Foundation and other donors, since 1990, have funded the World Vision Ghana Rural Water Project (GRWP) to drill wells for potable water supplies in the Greater Afram Plains (GAP) of Ghana. During the first two years of the program, drilling success rates using traditional methods ranged from 35 to 80 percent, depending on the area. The average drilling success rate for the program was approximately 50 percent. In an effort to increase the efficiency of drilling operations, the Desert Research Institute evaluated and developed techniques for application to well-siting strategies in the GAP area of Ghana. A critical project element was developing technical capabilities of in-country staff to independently implement the new strategies. Simple cost-benefit relationships were then used to evaluate the economic advantages of developing water resources using advanced siting methods. The application of advanced methods in the GAP area reveal an increase of 10 to 15 percent in the success rate over traditional methods. Aerial photography has been found to be the most useful of the imagery products covering the GAP area. An effective approach to geophysical exploration for groundwater has been the combined use of EM and resistivity methods. Economic analyses showed that the use of advanced methods is cost-effective when success rates with traditional methods are less than 70 to 90 percent. Finally, with the focus of GRWP activities shifting to Ghana's northern regions, new challenges in drilling success rates are being encountered. In certain districts, success rates as low as 35 percent are observed, raising questions about the efficacy of existing well-siting strategies in the current physical setting, and the validity of traditional cost-benefit analyses for assessing the economic aspects of water exploration in drought-stricken areas.

  13. Feasibility of Rainwater Harvesting to fulfill potable water demand using quantitative water management in low-lying delta regions of Asia

    NASA Astrophysics Data System (ADS)

    Mahmood, A.; Hossain, F.

    2016-12-01

    Low-lying deltas of Asian region are usually densely populated and located in developing countries situated at the downstream end of major rivers. Extensive dam construction by the upstream countries has now caused water scarcity in large portions of low-lying deltas. Most inhabitants depend on shallow tube well for safe drinking water that tend to suffer from water quality issues (e.g. Arsenic contamination). In addition, people also get infected from water borne diseases like Cholera and Typhoid due to lack of safe drinking water. Developing a centralized piped network based water supply system is often not a feasible option in rural regions. Due to social acceptability, environment friendliness, lower capital and maintenance cost, rainwater harvesting can be the most sustainable option to supply safe drinking water in rural areas. In this study, first we estimate the monthly rainfall variability using long precipitation climatology from satellite precipitation data. The upper and lower bounds of monthly harvestable rainwater were estimated for each satellite precipitation grid. Taking this lower bound of monthly harvestable rainwater as input, we use quantitative water management concept to determine the percent of the time of the year potable water demand can be fulfilled. Analysis indicates that a 6 m³ reservoir tank can fulfill the potable water demand of a 6 person family throughout a year in almost all parts of this region.

  14. A Low-Cost, In Situ Resistivity and Temperature Monitoring System

    EPA Science Inventory

    We present a low-cost, reliable method for long-term in situ autonomous monitoring of subsurface resistivity and temperature in a shallow, moderately heterogeneous subsurface. Probes, to be left in situ, were constructed at relatively low cost with close electrode spacing. Once i...

  15. Behavioral Determinants of Switching to Arsenic-Safe Water Wells: An Analysis of a Randomized Controlled Trial of Health Education Interventions Coupled With Water Arsenic Testing

    ERIC Educational Resources Information Center

    George, Christine Marie; Inauen, Jennifer; Perin, Jamie; Tighe, Jennifer; Hasan, Khaled; Zheng, Yan

    2017-01-01

    More than 100 million people globally are estimated to be exposed to arsenic in drinking water that exceeds the World Health Organization guideline of 10 µg/L. In an effort to develop and test a low-cost sustainable approach for water arsenic testing in Bangladesh, we conducted a randomized controlled trial which found arsenic educational…

  16. Ultrasonic Methods for Human Motion Detection

    DTIC Science & Technology

    2006-10-01

    contacts. The active method utilizes continuous wave ultrasonic Doppler sonar . Human motions have unique Doppler signatures and their combination...The present article reports results of human motion investigations with help of CW ultrasonic Doppler sonar . Low-cost, low-power ultrasonic motion...have been developed for operation in air [10]. Benefits of using ultrasonic CW Doppler sonar included the low-cost, low-electric noise, small size

  17. Pediatric electrical burns: management strategies.

    PubMed

    Zubair, M; Besner, G E

    1997-08-01

    The purpose of the present study was to analyse the course of patients hospitalised with electrical burn wounds in the past 25 years at a major children's hospital in the United States in order to devise safe and cost effective management strategies for these patients. The study was a retrospective chart review of patients with electrical injuries admitted to the hospital between 1971 and 1995. We identified 127 children who were included in the study. Injuries resulted from biting an electrical cord (oral injury) (n = 48), placing an object into an electrical socket (outlet injury) (n = 33), contacting a low voltage wire or appliance indoors (low voltage household injury) (n = 25), contacting a high voltage wire outdoors (high voltage wire injury) (n = 18), or being struck by lightning (n = 3). A retrospective review revealed that the great majority of patients with low voltage electrical injuries did not need admission to the hospital and could have been cared for on an outpatient basis. Almost every patient with high voltage injury had a justified admission due to the severity of the injury. On the basis of these results we conclude that we can safely reduce the number of admissions to the hospital for children with low voltage minor electrical injuries.

  18. Cost-effectiveness of outpatient management for febrile neutropenia in children with cancer.

    PubMed

    Teuffel, Oliver; Amir, Eitan; Alibhai, Shabbir M H; Beyene, Joseph; Sung, Lillian

    2011-02-01

    Inpatient management remains the standard of care for treatment of febrile neutropenia (FN) in children with cancer. Clinical data suggest, however, that outpatient management might be a safe and efficacious alternative for patients with low-risk FN episodes. A cost-utility model was created to compare 4 treatment strategies for low-risk FN. The base case considered pediatric cancer patients with low-risk FN. The model used a health care payer's perspective and a time horizon of 1 FN episode. Four treatment strategies were evaluated: (1) entire treatment in hospital with intravenous antibiotics (HospIV); (2) early discharge consisting of 48 hours of inpatient observation with intravenous antibiotics followed by oral outpatient treatment (EarlyDC); (3) entirely outpatient management with intravenous antibiotics (HomeIV); and (4) entirely outpatient management with oral antibiotics (HomePO). Outcome measures were quality-adjusted FN episodes (QAFNEs), costs (Canadian dollars), and incremental cost-effectiveness ratios. Parameter uncertainty was assessed with probabilistic sensitivity analyses. The most cost-effective strategy was HomeIV. It was cost-saving ($2732 vs $2757) and more effective (0.66 vs 0.55 QAFNE) as compared with HomePO. EarlyDC was slightly more effective (0.68 QAFNE) but significantly more expensive ($5579) than HomeIV, which resulted in an unacceptably high incremental cost-effectiveness ratio of more than $130 000 per QAFNE. HospIV was the least cost-effective strategy because it was more expensive ($14 493) and less effective (0.65 QAFNE) than EarlyDC. The findings of this decision-analytic model indicate that the substantially higher costs of inpatient management cannot be justified on the basis of safety and efficacy considerations or patient/parent preferences.

  19. Verification of Cold Working and Interference Levels at Fastener Holes

    DTIC Science & Technology

    2009-02-01

    of the Residual Stress Field on the Fatigue Coupons ........................................ 32 3.3.3 Fractography of Fatigue Test Coupons...predictions to fatigue experiment results (none of the literature we reviewed described fractography of cracks propagating through residual stress...ensures continued safety, readiness, and controlled maintenance costs. These methods augment and enhance traditional safe-life and damage tolerance

  20. A novel non-uniform control vector parameterization approach with time grid refinement for flight level tracking optimal control problems.

    PubMed

    Liu, Ping; Li, Guodong; Liu, Xinggao; Xiao, Long; Wang, Yalin; Yang, Chunhua; Gui, Weihua

    2018-02-01

    High quality control method is essential for the implementation of aircraft autopilot system. An optimal control problem model considering the safe aerodynamic envelop is therefore established to improve the control quality of aircraft flight level tracking. A novel non-uniform control vector parameterization (CVP) method with time grid refinement is then proposed for solving the optimal control problem. By introducing the Hilbert-Huang transform (HHT) analysis, an efficient time grid refinement approach is presented and an adaptive time grid is automatically obtained. With this refinement, the proposed method needs fewer optimization parameters to achieve better control quality when compared with uniform refinement CVP method, whereas the computational cost is lower. Two well-known flight level altitude tracking problems and one minimum time cost problem are tested as illustrations and the uniform refinement control vector parameterization method is adopted as the comparative base. Numerical results show that the proposed method achieves better performances in terms of optimization accuracy and computation cost; meanwhile, the control quality is efficiently improved. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  1. A micro-UAS to start prescribed fires

    USGS Publications Warehouse

    Beachly, Evan; Higgins, James; Laney, Christian; Elbaum, Sebastian; Detweiler, Carrick; Allen, Craig R.; Twidwell, Dirac

    2017-01-01

    Prescribed fires have many benefits, but existing ignition methods are dangerous, costly, or inefficient. This paper presents the design and evaluation of a micro-UAS that can start a prescribed fire from the air, while being operated from a safe distance and without the costs associated with aerial ignition from a manned aircraft. We evaluate the performance of the system in extensive controlled tests indoors. We verify the capabilities of the system to perform interior ignitions, a normally dangerous task, through the ignition of two prescribed fires alongside wildland firefighters.

  2. Affordable Launch Services using the Sport Orbit Transfer System

    NASA Astrophysics Data System (ADS)

    Goldstein, D. J.

    2002-01-01

    Despite many advances in small satellite technology, a low-cost, reliable method is needed to place spacecraft in their de- sired orbits. AeroAstro has developed the Small Payload ORbit Transfer (SPORTTM) system to provide a flexible low-cost orbit transfer capability, enabling small payloads to use low-cost secondary launch opportunities and still reach their desired final orbits. This capability allows small payloads to effectively use a wider variety of launch opportunities, including nu- merous under-utilized GTO slots. Its use, in conjunction with growing opportunities for secondary launches, enable in- creased access to space using proven technologies and highly reliable launch vehicles such as the Ariane family and the Starsem launcher. SPORT uses a suite of innovative technologies that are packaged in a simple, reliable, modular system. The command, control and data handling of SPORT is provided by the AeroAstro BitsyTM core electronics module. The Bitsy module also provides power regulation for the batteries and optional solar arrays. The primary orbital maneuvering capability is provided by a nitrous oxide monopropellant propulsion system. This system exploits the unique features of nitrous oxide, which in- clude self-pressurization, good performance, and safe handling, to provide a light-weight, low-cost and reliable propulsion capability. When transferring from a higher energy orbit to a lower energy orbit (i.e. GTO to LEO), SPORT uses aerobraking technol- ogy. After using the propulsion system to lower the orbit perigee, the aerobrake gradually slows SPORT via atmospheric drag. After the orbit apogee is reduced to the target level, an apogee burn raises the perigee and ends the aerobraking. At the conclusion of the orbit transfer maneuver, either the aerobrake or SPORT can be shed, as desired by the payload. SPORT uses a simple design for high reliability and a modular architecture for maximum mission flexibility. This paper will discuss the launch system and its application to small satellite launch without increasing risk. It will also discuss relevant issues such as aerobraking operations and radiation issues, as well as existing partnerships and patents for the system.

  3. Replacement of Expensive, Disposable Instruments With Old-fashioned Surgical Techniques for Improved Cost-effectiveness in Laparoscopic Hysterectomy

    PubMed Central

    Morrison, John E.

    2004-01-01

    Objective: Patients demand that health care and procedures in rural areas be provided by ambulatory surgery centers close to home. However, the reimbursement rate for such procedures in ambulatory centers is extremely low, so a standard classic intrafascial supracervical hysterectomy procedure needs to be more cost effective to be performed there. Instruments and disposable devices can make up ≥50% of hospital costs for this procedure, so any cost reduction has to focus on this aspect. Methods: We identified the 3 most expensive disposable devices: (1) an Endostapler, US $498 and 3 staple reloads, US $179 each; (2) a calibrated uterine resection tool 15 mm for encoring of the endocervical canal, US $853; and (3) a serrated edged macro morcellator for intraabdominal uterus morcellation, US $321, and substituted them using classic conservative surgical techniques. Results: From September 2001 to September 2002, we performed 26 procedures with this modified technique at an ambulatory surgery center with a follow-up of 6.7 (2 to 14) months. This modified operative technique was feasible; no conversions were necessary, and no complications occurred. Cost savings were US $2209 per procedure; additional costs were US $266.33 for suture material and an Endopouch, resulting in an overall savings of US $50 509.42. The disadvantage was an increase in operating room time of about 1 hour 20 minutes per case. Conclusion: These modifications in the classic intrafascial supracervical hysterectomy technique have proven to be feasible, safe, and highly cost effective, especially for a rural ambulatory surgery center. Long-term follow-up is necessary to further evaluate these operative modifications. PMID:15119671

  4. Costs and benefits of rapid screening of methicillin-resistant Staphylococcus aureus carriage in intensive care units: a prospective multicenter study

    PubMed Central

    2012-01-01

    Introduction Pre-emptive isolation of suspected methicillin-resistant Staphylococcus aureus (MRSA) carriers is a cornerstone of successful MRSA control policies. Implementation of such strategies is hampered when using conventional cultures with diagnostic delays of three to five days, as many non-carriers remain unnecessarily isolated. Rapid diagnostic testing (RDT) reduces the amount of unnecessary isolation days, but costs and benefits have not been accurately determined in intensive care units (ICUs). Methods Embedded in a multi-center hospital-wide study in 12 Dutch hospitals we quantified cost per isolation day avoided using RDT for MRSA, added to conventional cultures, in ICUs. BD GeneOhm™ MRSA PCR (IDI) and Xpert MRSA (GeneXpert) were subsequently used during 17 and 14 months, and their test characteristics were calculated with conventional culture results as reference. We calculated the number of pre-emptive isolation days avoided and incremental costs of adding RDT. Results A total of 163 patients at risk for MRSA carriage were screened and MRSA prevalence was 3.1% (n = 5). Duration of isolation was 27.6 and 21.4 hours with IDI and GeneXpert, respectively, and would have been 96.0 hours when based on conventional cultures. The negative predictive value was 100% for both tests. Numbers of isolation days were reduced by 44.3% with PCR-based screening at the additional costs of €327.84 (IDI) and €252.14 (GeneXpert) per patient screened. Costs per isolation day avoided were €136.04 (IDI) and €121.76 (GeneXpert). Conclusions In a low endemic setting for MRSA, RDT safely reduced the number of unnecessary isolation days on ICUs by 44%, at the costs of €121.76 to €136.04 per isolation day avoided. PMID:22314204

  5. How low can you go? The impact of reduced benefits and increased cost sharing.

    PubMed

    Lee, Jason S; Tollen, Laura

    2002-01-01

    Amid escalating health care costs and a managed care backlash, employers are considering traditional cost control methods from the pre-managed care era. We use an actuarial model to estimate the premium-reducing effects of two such methods: increasing employee cost sharing and reducing benefits. Starting from a baseline plan with rich benefits and low cost sharing, estimated premium savings as a result of eliminating five specific benefits were about 22 percent. The same level of savings was also achieved by increasing cost sharing from a 15 dollars copayment with no deductible to 20 percent coinsurance and a 250 dollars deductible. Further increases in cost sharing produced estimated savings of up to 50 percent. We discuss possible market- and individual-level effects of the proliferation of plans with high cost sharing and low benefits.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duan, Sisi; Li, Yun; Levitt, Karl N.

    Consensus is a fundamental approach to implementing fault-tolerant services through replication where there exists a tradeoff between the cost and the resilience. For instance, Crash Fault Tolerant (CFT) protocols have a low cost but can only handle crash failures while Byzantine Fault Tolerant (BFT) protocols handle arbitrary failures but have a higher cost. Hybrid protocols enjoy the benefits of both high performance without failures and high resiliency under failures by switching among different subprotocols. However, it is challenging to determine which subprotocols should be used. We propose a moving target approach to switch among protocols according to the existing systemmore » and network vulnerability. At the core of our approach is a formalized cost model that evaluates the vulnerability and performance of consensus protocols based on real-time Intrusion Detection System (IDS) signals. Based on the evaluation results, we demonstrate that a safe, cheap, and unpredictable protocol is always used and a high IDS error rate can be tolerated.« less

  7. Polymer adhesion predictions for oral dosage forms to enhance drug administration safety. Part 2: In vitro approach using mechanical force methods.

    PubMed

    Drumond, Nélio; Stegemann, Sven

    2018-06-01

    Predicting the potential for unintended adhesion of solid oral dosage forms (SODF) to mucosal tissue is an important aspect that should be considered during drug product development. Previous investigations into low strength mucoadhesion based on particle interactions methods provided evidence that rheological measurements could be used to obtain valid predictions for the development of SODF coatings that can be safely swallowed. The aim of this second work was to estimate the low mucoadhesive strength properties of different polymers using in vitro methods based on mechanical forces and to identify which methods are more precise when measuring reduced mucoadhesion. Another aim was to compare the obtained results to the ones achieved with in vitro particle interaction methods in order to evaluate which methodology can provide stronger predictions. The combined results correlate between particle interaction methods and mechanical force measurements. The polyethylene glycol grades (PEG) and carnauba wax showed the lowest adhesive potential and are predicted to support safe swallowing. Hydroxypropyl methylcellulose (HPMC) along with high molecular grades of polyvinylpyrrolidone (PVP) and polyvinyl alcohol (PVA) exhibited strong in vitro mucoadhesive strength. The combination of rheological and force tensiometer measurements should be considered when assessing the reduced mucoadhesion of polymer coatings to support safe swallowing of SODF. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Assessing the quality of cost management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fayne, V.; McAllister, A.; Weiner, S.B.

    1995-12-31

    Managing environmental programs can be effective only when good cost and cost-related management practices are developed and implemented. The Department of Energy`s Office of Environmental Management (EM), recognizing this key role of cost management, initiated several cost and cost-related management activities including the Cost Quality Management (CQM) Program. The CQM Program includes an assessment activity, Cost Quality Management Assessments (CQMAs), and a technical assistance effort to improve program/project cost effectiveness. CQMAs provide a tool for establishing a baseline of cost-management practices and for measuring improvement in those practices. The result of the CQMA program is an organization that has anmore » increasing cost-consciousness, improved cost-management skills and abilities, and a commitment to respond to the public`s concerns for both a safe environment and prudent budget outlays. The CQMA program is part of the foundation of quality management practices in DOE. The CQMA process has contributed to better cost and cost-related management practices by providing measurements and feedback; defining the components of a quality cost-management system; and helping sites develop/improve specific cost-management techniques and methods.« less

  9. Devices for preventing percutaneous exposure injuries caused by needles in healthcare personnel.

    PubMed

    Reddy, Viraj K; Lavoie, Marie-Claude; Verbeek, Jos H; Pahwa, Manisha

    2017-11-14

    Percutaneous exposure injuries from devices used for blood collection or for injections expose healthcare workers to the risk of blood borne infections such as hepatitis B and C, and human immunodeficiency virus (HIV). Safety features such as shields or retractable needles can possibly contribute to the prevention of these injuries and it is important to evaluate their effectiveness. To determine the benefits and harms of safety medical devices aiming to prevent percutaneous exposure injuries caused by needles in healthcare personnel versus no intervention or alternative interventions. We searched CENTRAL, MEDLINE, EMBASE, NHSEED, Science Citation Index Expanded, CINAHL, Nioshtic, CISdoc and PsycINFO (until 11 November 2016). We included randomised controlled trials (RCT), controlled before and after studies (CBA) and interrupted time-series (ITS) designs of the effect of safety engineered medical devices on percutaneous exposure injuries in healthcare staff. Two of the authors independently assessed study eligibility and risk of bias and extracted data. We synthesized study results with a fixed-effect or random-effects model meta-analysis where appropriate. We included six RCTs with 1838 participants, two cluster-RCTs with 795 participants and 73,454 patient days, five CBAs with approximately 22,000 participants and eleven ITS with an average of 13.8 data points. These studies evaluated safe modifications of blood collection systems, intravenous (IV) systems, injection systems, multiple devices, sharps containers and legislation on the implementation of safe devices. We estimated the needlestick injury (NSI) rate in the control groups to be about one to five NSIs per 1000 person-years. There were only two studies from low- or middle-income countries. The risk of bias was high in 20 of 24 studies. Safe blood collection systems:We found one RCT that found a safety engineered blood gas syringe having no considerable effect on NSIs (Relative Risk (RR) 0.2, 95% Confidence Interval (95% CI) 0.01 to 4.14, 550 patients, very low quality evidence). In one ITS study, safe blood collection systems decreased NSIs immediately after the introduction (effect size (ES) -6.9, 95% CI -9.5 to -4.2) but there was no further decrease over time (ES -1.2, 95% CI -2.5 to 0.1, very low quality evidence). Another ITS study evaluated an outdated recapping shield, which we did not consider further. Safe Intravenous systemsThere was very low quality evidence in two ITS studies that NSIs were reduced with the introduction of safe IV devices, whereas one RCT and one CBA study provided very low quality evidence of no effect. However, there was moderate quality evidence produced by four other RCT studies that these devices increased the number of blood splashes when the safety system had to be engaged actively (relative risk (RR) 1.6, 95% CI 1.08 to 2.36). In contrast there was low quality evidence produced by two RCTs of passive systems that showed no effect on blood splashes. Yet another RCT produced low quality evidence that a different safe active IV system also decreased the incidence of blood leakages. Safe injection devicesThere was very low quality evidence provided by one RCT and one CBA study showing that introduction of safe injection devices did not considerably change the NSI rate. One ITS study produced low quality evidence showing that the introduction of safe passive injection systems had no effect on NSI rate when compared to safe active injection systems. Multiple safe devicesThere was very low quality evidence from one CBA study and two ITS studies. According to the CBA study, the introduction of multiple safe devices resulted in a decrease in NSI,whereas the two ITS studies found no change. Safety containersOne CBA study produced very low quality evidence showing that the introduction of safety containers decreased NSI. However, two ITS studies evaluating the same intervention found inconsistent results. LegislationThere was low to moderate quality evidence in two ITS studies that introduction of legislation on the use of safety-engineered devices reduced the rate of NSIs among healthcare workers. There was also low quality evidence which showed a decrease in the trend over time for NSI rates.Twenty out of 24 studies had a high risk of bias and the lack of evidence of a beneficial effect could be due to both confounding and bias. This does not mean that these devices are not effective. For safe blood collection systems, we found very low quality evidence of inconsistent effects on NSIs. For safe passive intravenous systems, we found very low quality evidence of a decrease in NSI and a reduction in the incidence of blood leakage events but moderate quality evidence that active systems may increase exposure to blood. For safe injection needles, the introduction of multiple safety devices or the introduction of sharps containers the evidence was inconsistent or there was no clear evidence of a benefit. There was low to moderate quality evidence that introduction of legislation probably reduces NSI rates.More high-quality cluster-randomised controlled studies that include cost-effectiveness measures are needed, especially in countries where both NSIs and blood-borne infections are highly prevalent.

  10. Application of Hazard Analysis Critical Control Point in the local manufacture of ready-to-use therapeutic foods (RUTFs).

    PubMed

    Henry, C Jeya K; Xin, Janice Lim Wen

    2014-06-01

    The local manufacture of ready-to-use therapeutic foods (RUTFs) is increasing, and there is a need to develop methods to ensure their safe production. We propose the application of Hazard Analysis Critical Control Point (HACCP) principles to achieve this goal. The basic principles of HACCP in the production of RUTFs are outlined. It is concluded that the implementation of an HACCP system in the manufacture of RUTFs is not only feasible but also attainable. The introduction of good manufacturing practices, coupled with an effective HACCP system, will ensure that RUTFs are produced in a cost-effective, safe, and hygienic manner.

  11. Metastable Metal Hydrides for Hydrogen Storage

    DOE PAGES

    Graetz, Jason

    2012-01-01

    The possibility of using hydrogen as a reliable energy carrier for both stationary and mobile applications has gained renewed interest in recent years due to improvements in high temperature fuel cells and a reduction in hydrogen production costs. However, a number of challenges remain and new media are needed that are capable of safely storing hydrogen with high gravimetric and volumetric densities. Metal hydrides and complex metal hydrides offer some hope of overcoming these challenges; however, many of the high capacity “reversible” hydrides exhibit a large endothermic decomposition enthalpy making it difficult to release the hydrogen at low temperatures. Onmore » the other hand, the metastable hydrides are characterized by a low reaction enthalpy and a decomposition reaction that is thermodynamically favorable under ambient conditions. The rapid, low temperature hydrogen evolution rates that can be achieved with these materials offer much promise for mobile PEM fuel cell applications. However, a critical challenge exists to develop new methods to regenerate these hydrides directly from the reactants and hydrogen gas. This spotlight paper presents an overview of some of the metastable metal hydrides for hydrogen storage and a few new approaches being investigated to address the key challenges associated with these materials.« less

  12. Plant-made vaccines against West Nile virus are potent, safe, and economically feasible

    PubMed Central

    Chen, Qiang

    2015-01-01

    The threat of West Nile virus (WNV) epidemics with increasingly severe neuroinvasive infections demands the development and licensing of effective vaccines. To date, vaccine candidates based on inactivated, live-attenuated, or chimeric virus, and viral DNA and WNV protein subunits have been developed. Some have been approved for veterinary use or are under clinical investigation, yet no vaccine has been licensed for human use. Reaching the milestone of a commercialized human vaccine, however, may largely depend on the economics of vaccine production. Analysis suggests that currently only novel low-cost production technologies would allow vaccination to outcompete the cost of surveillance and clinical treatment. Here, we review progress using plants to address the economic challenges of WNV vaccine production. The advantages of plants as hosts for vaccine production in cost, speed and scalability, especially those of viral vector-based transient expression systems, are discussed. The progress in developing WNV subunit vaccines in plants is reviewed within the context of their expression, characterization, downstream processing, and immunogenicity in animal models. The development of vaccines based on enveloped and non-enveloped virus-like particles is also discussed. These advancements suggest that plants may provide a production platform that offers potent, safe and affordable human vaccines against WNV. PMID:25676782

  13. Plant-made vaccines against West Nile virus are potent, safe, and economically feasible.

    PubMed

    Chen, Qiang

    2015-05-01

    The threat of West Nile virus (WNV) epidemics with increasingly severe neuroinvasive infections demands the development and licensing of effective vaccines. To date, vaccine candidates based on inactivated, live-attenuated, or chimeric virus, and viral DNA and WNV protein subunits have been developed. Some have been approved for veterinary use or are under clinical investigation, yet no vaccine has been licensed for human use. Reaching the milestone of a commercialized human vaccine, however, may largely depend on the economics of vaccine production. Analysis suggests that currently only novel low-cost production technologies would allow vaccination to outcompete the cost of surveillance and clinical treatment. Here, we review progress using plants to address the economic challenges of WNV vaccine production. The advantages of plants as hosts for vaccine production in cost, speed and scalability, especially those of viral vector-based transient expression systems, are discussed. The progress in developing WNV subunit vaccines in plants is reviewed within the context of their expression, characterization, downstream processing, and immunogenicity in animal models. The development of vaccines based on enveloped and non-enveloped virus-like particles is also discussed. These advancements suggest that plants may provide a production platform that offers potent, safe and affordable human vaccines against WNV. Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendell, D.

    This talk addresses the impact that future price uncertainty and current low oil and gas prices have on the conduct and management of R&D in the upstream business. Uncertainty in future prices underscores the need to develop technology that will improve our ability to reduce technical uncertainties in investment decisions, to lower all costs and to operate in a flawless way. Low current prices result in a need to be more efficient and cost conscious in everything we do, including R&D. Since the price environment provides little tolerance for mistakes, we need the best possible definition of the hydrocarbon resourcesmore » that we find before committing to development. Furthermore, we must find and define the resource at the lowest possible cost, and develop it in an efficient way that is cost effective, safe and environmentally acceptable. The vital role of research includes improving tools for reconstructing basin histories, predicting hydrocarbon generation, migration and trapping, and improving the quality of seismic data and attribute analysis while reducing acquisition cost. Improved methods for interpreting the data and for integrating it into the evaluation and decision making process also facilitates success. We need to continually strive for the competitive advantage provided by leading edge research, while making maximum use of outsourcing and leveraging to get the most out of every research dollar spent. Systematic prioritization and highgrading of our research portfolio is particularly important in achieving this balance. Exxon understands the importance of R&D to the upstream business, and we are committed to managing our resources to provide the value added research needed to address today`s needs as well as those we know will be there down the road. Exxon has been a successful player in this industry for many decades and we believe that our future success is closely tied to our ability to continually generate key research breakthroughs in an efficient way.« less

  15. Medical abortion: understanding perspectives of rural and marginalized women from rural South India.

    PubMed

    Sri, B Subha; Ravindran, T K Sundari

    2012-09-01

    To understand how rural and other groups of marginalized women define safe abortion; their perspectives and concerns regarding medical abortion (MA); and what factors affect their access to safe abortion. Focus group discussions were held with various groups of rural and marginalized women in Tamil Nadu to understand their perspectives and concerns on abortion, especially MA. Nearly a decade after mifepristone was approved for abortion in India, most study participants had never heard of MA. When they learned of the method, most preferred it over other methods of abortion. The women also had questions and concerns about the method and recommendations on how services should be provided. Their definition of a "safe abortion" included criteria beyond medical safety. They placed a high priority on "social safety," including confidentiality and privacy. In their view, factors affecting access to safe abortion and choice of provider included cost, assurance of secrecy, promptness of service provision, and absence of provider gatekeeping and provider-imposed conditions for receiving services. Women's preference for MA shows the potential of this technology to address the problem of unsafe abortion in India. Women need better access to information and services to realize this potential, however. Women's preferences regarding information dissemination and service provision need to be taken into account if policies and programs are to be truly responsive to the needs of marginalized women. Copyright © 2012. Published by Elsevier Ireland Ltd.

  16. Global challenges in water, sanitation and health.

    PubMed

    Moe, Christine L; Rheingans, Richard D

    2006-01-01

    The year 2005 marks the beginning of the "International Decade for Action: Water for Life" and renewed effort to achieve the Millennium Development Goals (MDGS) to reduce by half the proportion of the world's population without sustainable access to safe drinking water and sanitation by 2015. Currently, UNICEF and WHO estimate that 1.1 billion people lack access to improved water supplies and 2.6 billion people lack adequate sanitation. Providing safe water and basic sanitation to meet the MDGs will require substantial economic resources, sustainable technological solutions and courageous political will. We review five major challenges to providing safe water and sanitation on a global basis: (1) contamination of water in distribution systems, (2) growing water scarcity and the potential for water reuse and conservation, (3) implementing innovative low-cost sanitation systems, (4) providing sustainable water supplies and sanitation for megacities, and (5) reducing global and regional disparities in access to water and sanitation and developing financially sustainable water and sanitation services.

  17. A novel liquid organic hydrogen carrier system based on catalytic peptide formation and hydrogenation

    PubMed Central

    Hu, Peng; Fogler, Eran; Diskin-Posner, Yael; Iron, Mark A.; Milstein, David

    2015-01-01

    Hydrogen is an efficient green fuel, but its low energy density when stored under high pressure or cryogenically, and safety issues, presents significant disadvantages; hence finding efficient and safe hydrogen carriers is a major challenge. Of special interest are liquid organic hydrogen carriers (LOHCs), which can be readily loaded and unloaded with considerable amounts of hydrogen. However, disadvantages include high hydrogen pressure requirements, high reaction temperatures for both hydrogenation and dehydrogenation steps, which require different catalysts, and high LOHC cost. Here we present a readily reversible LOHC system based on catalytic peptide formation and hydrogenation, using an inexpensive, safe and abundant organic compound with high potential capacity to store and release hydrogen, applying the same catalyst for loading and unloading hydrogen under relatively mild conditions. Mechanistic insight of the catalytic reaction is provided. We believe that these findings may lead to the development of an inexpensive, safe and clean liquid hydrogen carrier system. PMID:25882348

  18. Behaviour of one-step spray-coated carbon nanotube supercapacitor in ambient light harvester circuit with printed organic solar cell and electrochromic display.

    PubMed

    Tuukkanen, Sampo; Välimäki, Marja; Lehtimäki, Suvi; Vuorinen, Tiina; Lupo, Donald

    2016-03-09

    A printed energy harvesting and storage circuit powered by ambient office lighting and its use to power a printed display is reported. The autonomous device is composed of three printed electronic components: an organic photovoltaic module, a carbon-nanotubes-only supercapacitor and an electrochromic display element. Components are fabricated from safe and environmentally friendly materials, and have been fabricated using solution processing methods, which translate into low-cost and high-throughput manufacturing. A supercapacitor made of spray-coated carbon nanotube based ink and aqueous NaCl electrolyte was charged using a printed organic photovoltaic module exposed to office lighting conditions. The supercapacitor charging rate, self-discharge rate and display operation were studied in detail. The supercapacitor self-discharge rate was found to depend on the charging rate. The fully charged supercapacitor was used as a power source to run the electrochromic display over 50 times.

  19. Office-Based Spirometry: A New Model of Care in Preoperative Assessment for Low-Risk Lung Resections.

    PubMed

    Hudson, Jessica L; Bell, Jennifer M; Crabtree, Traves D; Kreisel, Daniel; Patterson, G Alexander; Meyers, Bryan F; Puri, Varun

    2018-01-01

    Formal pulmonary function testing with laboratory spirometry (LS) is the standard of care for risk stratification before lung resection. LS and handheld office spirometry (OS) are clinically comparable for forced expiratory volume in 1 second and forced vital capacity. We investigated the safety of preoperative risk stratification based solely on OS. Patients at low-risk for cardiopulmonary complications were enrolled in a single-center prospective study and underwent preoperative OS. Formal LS was not performed when forced expiratory volume in 1 second was more than 60% by OS. Propensity score matching was used to compare patients in the OS group to low-risk institutional database patients (2008 to 2015) who underwent LS and lung resection. Standardized mean differences determined model covariate balance. The McNemar test and log-rank test were performed, respectively, for categorical and continuous paired outcome data. There were 66 prospectively enrolled patients who received OS and underwent pulmonary resection, and 1,290 patients received preoperative LS, resulting in 52 propensity score-matched pairs (83%). There were no deaths and two 30-day readmissions per group. The major morbidity risk was similar in each group (7.7%). All analyses of discordant pair morbidity had p exceeding 0.56. There was no association between length of stay and exposure to OS vs LS (p = 0.31). The estimated annual institutional cost savings from performing OS only and avoiding LS was $38,000. Low-risk patients undergoing lung resection can be adequately and safely assessed using OS without formal LS, with significant cost savings. With upcoming bundled care reimbursement paradigms, such safe and effective strategies are likely to be more widely used. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Low-cost compact MEMS scanning ladar system for robotic applications

    NASA Astrophysics Data System (ADS)

    Moss, Robert; Yuan, Ping; Bai, Xiaogang; Quesada, Emilio; Sudharsanan, Rengarajan; Stann, Barry L.; Dammann, John F.; Giza, Mark M.; Lawler, William B.

    2012-06-01

    Future robots and autonomous vehicles require compact low-cost Laser Detection and Ranging (LADAR) systems for autonomous navigation. Army Research Laboratory (ARL) had recently demonstrated a brass-board short-range eye-safe MEMS scanning LADAR system for robotic applications. Boeing Spectrolab is doing a tech-transfer (CRADA) of this system and has built a compact MEMS scanning LADAR system with additional improvements in receiver sensitivity, laser system, and data processing system. Improved system sensitivity, low-cost, miniaturization, and low power consumption are the main goals for the commercialization of this LADAR system. The receiver sensitivity has been improved by 2x using large-area InGaAs PIN detectors with low-noise amplifiers. The FPGA code has been updated to extend the range to 50 meters and detect up to 3 targets per pixel. Range accuracy has been improved through the implementation of an optical T-Zero input line. A compact commercially available erbium fiber laser operating at 1550 nm wavelength is used as a transmitter, thus reducing the size of the LADAR system considerably from the ARL brassboard system. The computer interface has been consolidated to allow image data and configuration data (configuration settings and system status) to pass through a single Ethernet port. In this presentation we will discuss the system architecture and future improvements to receiver sensitivity using avalanche photodiodes.

  1. Demonstration of Lightweight Engineering Solutions for a Low-Cost Safe Explosive Ordnance Destruct Tool

    DTIC Science & Technology

    2007-12-01

    Staff) and Mr. Doug Learned ( Intercity Manufacturing), whose efficiency and expertise was vital in manufacturing the parts required for our tests...detonation products caused by the hollow cavity. Upon initiation of a hollow lined charge, the resulting high pressure shock wave travels outward...5.6 km/s for the brass encased charge at 2 and 3 CD. This indicates that the jet must be traveling at velocities greater than the estimates, which

  2. Development of a Health System-Based Nurse-Delivered Aromatherapy Program.

    PubMed

    Joswiak, Denise; Kinney, Mary Ellen; Johnson, Jill R; Kolste, Alison K; Griffin, Kristen H; Rivard, Rachael L; Dusek, Jeffery A

    2016-04-01

    Healthcare systems are increasingly looking to integrate aromatherapy (essential oils) as a safe, low-cost, and nonpharmacologic option for patient care to reduce pain, nausea, and anxiety and to improve sleep. This article describes the development and implementation of a healthcare system-wide program of nurse-delivered essential oil therapeutic interventions to inpatients throughout an acute care setting. In addition, we provide lessons learned for nursing administrators interested in developing similar nurse-delivered aromatherapy programs.

  3. KSC-2013-1047

    NASA Image and Video Library

    2013-01-09

    CAPE CANAVERAL, Fla. -- At a news conference NASA officials and industry partners discuss progress of the agency's Commercial Crew Program. Among those participating in the briefing is Ed Mango, NASA Commercial Crew Program manager. Through CCP, NASA is facilitating the development of U.S. commercial crew space transportation capabilities to achieve safe, reliable and cost-effective access to and from low-Earth orbit for potential future government and commercial customers. For more information, visit http://www.nasa.gov/commercialcrew Photo credit: NASA/Kim Shiflett

  4. Spraylon fluorocarbon encapsulation for silicon solar cell arrays

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A development program was performed for evaluating, modifying, and optimizing the Lockheed formulated liquid transparent filmforming Spraylon fluorocarbon protective coating for silicon solar cells and modules. The program objectives were designed to meet the requirements of the low-cost automated solar cell array fabrication process. As part of the study, a computer program was used to establish the limits of the safe working stress in the coated silicon solar cell array system under severe thermal shock.

  5. Feasibility of a Low-Cost, Interactive Gaming System to Assess Balance in Older Women.

    PubMed

    Hall, Courtney D; Clevenger, Carolyn K; Wolf, Rachel A; Lin, James S; Johnson, Theodore M; Wolf, Steven L

    2016-01-01

    The use of low-cost interactive game technology for balance rehabilitation has become more popular recently, with generally good outcomes. Very little research has been undertaken to determine whether this technology is appropriate for balance assessment. The Wii balance board has good reliability and is comparable to a research-grade force plate; however, recent studies examining the relationship between Wii Fit games and measures of balance and mobility demonstrate conflicting findings. This study found that the Wii Fit was feasible for community-dwelling older women to safely use the balance board and quickly learn the Wii Fit games. The Ski Slalom game scores were strongly correlated with several balance and mobility measures, whereas Table Tilt game scores were not. Based on these findings, the Ski Slalom game may have utility in the evaluation of balance problems in community-dwelling older adults.

  6. Graphene-Based Ultra-Light Batteries for Aircraft

    NASA Technical Reports Server (NTRS)

    Calle, Carlos I.; Kaner, Richard B.

    2014-01-01

    Develop a graphene-based ultracapacitor prototype that is flexible, thin, lightweight, durable, low cost, and safe and that will demonstrate the feasibility for use in aircraft center dot These graphene-based devices store charge on graphene sheets and take advantage of the large accessible surface area of graphene (2,600 m2/g) to increase the electrical energy that can be stored. center dot The proposed devices should have the electrical storage capacity of thin-film-ion batteries but with much shorter charge/discharge cycle times as well as longer lives center dot The proposed devices will be carbon-based and so will not have the same issues with flammability or toxicity as the standard lithium-based storage cells There are two main established methods for the storage and delivery of electrical energy: center dot Batteries - Store energy with electrochemical reactions - High energy densities - Slow charge/discharge cycles - Used in applications requiring large amounts of energy ? aircraft center dot Electrochemical capacitors - Store energy in electrochemical double layers - Fast charge/discharge cycles - Low energy densities - Used in electronics devices - Large capacitors are used in truck engine cranking

  7. The Solar Umbrella: A Low-cost Demonstration of Scalable Space Based Solar Power

    NASA Technical Reports Server (NTRS)

    Contreras, Michael T.; Trease, Brian P.; Sherwood, Brent

    2013-01-01

    Within the past decade, the Space Solar Power (SSP) community has seen an influx of stakeholders willing to entertain the SSP prospect of potentially boundless, base-load solar energy. Interested parties affiliated with the Department of Defense (DoD), the private sector, and various international entities have all agreed that while the benefits of SSP are tremendous and potentially profitable, the risk associated with developing an efficient end to end SSP harvesting system is still very high. In an effort to reduce the implementation risk for future SSP architectures, this study proposes a system level design that is both low-cost and seeks to demonstrate the furthest transmission of wireless power to date. The overall concept is presented and each subsystem is explained in detail with best estimates of current implementable technologies. Basic cost models were constructed based on input from JPL subject matter experts and assume that the technology demonstration would be carried out by a federally funded entity. The main thrust of the architecture is to demonstrate that a usable amount of solar power can be safely and reliably transmitted from space to the Earth's surface; however, maximum power scalability limits and their cost implications are discussed.

  8. The need for family planning and safe abortion services among women sex workers seeking STI care in Cambodia.

    PubMed

    Delvaux, Thérèse; Crabbé, François; Seng, Sopheap; Laga, Marie

    2003-05-01

    In Cambodia, clinics established for the prevention and management of sexually transmitted infections (STIs) in women sex workers do not address other reproductive health services. The aim of this study was to assess the need for more comprehensive sexual and reproductive health services for women sex workers in Cambodia. In January 2000, relevant documents were reviewed, interviews with key informants carried out and group interviews with women sex workers conducted. Medical records from women sex workers were also reviewed and some data collected prospectively in one government STI clinic. Interviews with the women and data from the government clinic indicated that excluding condoms, a very low proportion of women sex workers were currently using a modern contraceptive method--5% of 38 women and 1.6% of 632 women, respectively. Induced abortion was widely used but was perceived to be risky and costly. Data from a mobile team intervention and the government clinic respectively showed that 25.5% (n = 1744) and 21.9% (n = 588) of women sex workers reported at least one previous induced abortion. These findings reveal the need for accessible contraception and safe abortion services among sex workers in Cambodia, and raise the issue of the reproductive rights and reproductive health needs of women sex workers in general.

  9. Low-Cost Aqueous Coal Desulfurization

    NASA Technical Reports Server (NTRS)

    Kalvinskas, J. J.; Vasilakos, N.; Corcoran, W. H.; Grohmann, K.; Rohatgi, N. K.

    1982-01-01

    Water-based process for desulfurizing coal not only eliminates need for costly organic solvent but removes sulfur more effectively than an earlier solvent-based process. New process could provide low-cost commercial method for converting high-sulfur coal into environmentally acceptable fuel.

  10. Cost-effectiveness analysis of unsafe abortion and alternative first-trimester pregnancy termination strategies in Nigeria and Ghana.

    PubMed

    Hu, Delphine; Grossman, Daniel; Levin, Carol; Blanchard, Kelly; Adanu, Richard; Goldie, Sue J

    2010-06-01

    To explore the policy implications of increasing access to safe abortion in Nigeria and Ghana, we developed a computer-based decision analytic model which simulates induced abortion and its potential complications in a cohort of women, and comparatively assessed the cost-effectiveness of unsafe abortion and three first-trimester abortion modalities: hospital-based dilatation and curettage, hospital- and clinic-based manual vacuum aspiration (MVA), and medical abortion using misoprostol (MA). Assuming all modalities are equally available, clinic-based MVA is the most cost-effective option in Nigeria. If clinic-based MVA is not available, MA is the next best strategy. Conversely, in Ghana, MA is the most cost-effective strategy, followed by clinic-based MVA if MA is not available. From a real world policy perspective, increasing access to safe abortion in favor over unsafe abortion is the single most important factor in saving lives and societal costs, and is more influential than the actual choice of safe abortion modality.

  11. Comparative study of balloon and metal olive dilators for endoscopic management of benign anastomotic rectal strictures: clinical and cost-effectiveness outcomes.

    PubMed

    Xinopoulos, Dimitrios; Kypreos, Dimitrios; Bassioukas, Stefanos P; Korkolis, Dimitrios; Mavridis, Konstantinos; Scorilas, Andreas; Dimitroulopoulos, Dimitrios; Loukou, Argyro; Paraskevas, Emmanouel

    2011-03-01

    Postoperative anastomotic strictures frequently complicate colorectal resection. Currently, various endoscopic techniques are being employed in their management, but the establishment of an optimal therapeutic strategy is still pending. The purpose of our study is to compare through-the-scope (TTS) balloon dilators versus Eder-Puestow metal olive dilators in the treatment of postoperative benign rectal strictures, considering the clinical outcome and cost-effectiveness of each method. A total of 39 patients with benign anastomotic rectal stenosis were retrospectively studied. In group A, 15 patients underwent dilation with Eder-Puestow metal olives, while in group B 19 patients were treated by means of TTS balloon dilators. The technical and clinical success of dilation, complications, number of repeated sessions required, disease-free time intervals, and the overall cost of each procedure were evaluated. Dilations were technically successful in all patients. No major complications occurred in either group. The number of dilations needed, rate of stricture recurrence, and duration of stenosis-free time intervals were not statistically significantly different between the two groups. Both methods proved more effective in older patients, given the greater number of dilations required in younger patients of both groups and higher frequency of stricture relapse in younger balloon-dilated patients (median 64.00 years) compared with older ones (median 75.00 years) (p = 0.001). An indisputable advantage of the Eder-Puestow technique, compared with TTS balloon dilators, is the low cost of equipment (median 22.30 compared with 680 , respectively; p < 0.001). Endoscopic dilation of postoperative benign rectal strictures is equally effective and safe, especially in older patients, when performed by Eder-Puestow bougies or TTS balloon dilators. However, metal olivary tips seem to surpass balloon dilators when considering the obvious economical benefits of the first method.

  12. Lessons Learned in the Design and Use of IP1 / IP2 Flexible Packaging - 13621

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanchez, Mike; Reeves, Wendall; Smart, Bill

    2013-07-01

    For many years in the USA, Low Level Radioactive Waste (LLW), contaminated soils and construction debris, have been transported, interim stored, and disposed of, using IP1 / IP2 metal containers. The performance of these containers has been more than adequate, with few safety occurrences. The containers are used under the regulatory oversight of the US Department of Transportation (DOT), 49 Code of Federal Regulations (CFR). In the late 90's the introduction of flexible packaging for the transport, storage, and disposal of low level contaminated soils and construction debris was introduced. The development of flexible packaging came out of a needmore » for a more cost effective package, for the large volumes of waste generated by the decommissioning of many of the US Department of Energy (DOE) legacy sites across the US. Flexible packaging had to be designed to handle a wide array of waste streams, including soil, gravel, construction debris, and fine particulate dust migration. The design also had to meet all of the IP1 requirements under 49CFR 173.410, and be robust enough to pass the IP2 testing 49 CFR 173.465 required for many LLW shipments. Tens of thousands of flexible packages have been safely deployed and used across the US nuclear industry as well as for hazardous non-radioactive applications, with no recorded release of radioactive materials. To ensure that flexible packages are designed properly, the manufacturer must use lessons learned over the years, and the tests performed to provide evidence that these packages are suitable for transporting low level radioactive wastes. The design and testing of flexible packaging for LLW, VLLW and other hazardous waste streams must be as strict and stringent as the design and testing of metal containers. The design should take into consideration the materials being loaded into the package, and should incorporate the right materials, and manufacturing methods, to provide a quality, safe product. Flexible packaging can be shown to meet the criteria for safe and fit for purpose packaging, by meeting the US DOT regulations, and the IAEA Standards for IP-1 and IP-2 including leak tightness. (authors)« less

  13. Assessing the microbiological performance and potential cost of boiling drinking water in urban Zambia.

    PubMed

    Psutka, Rebecca; Peletz, Rachel; Michelo, Sandford; Kelly, Paul; Clasen, Thomas

    2011-07-15

    Boiling is the most common method of disinfecting water in the home and the benchmark against which other point-of-use water treatment is measured. In a six-week study in peri-urban Zambia, we assessed the microbiological effectiveness and potential cost of boiling among 49 households without a water connection who reported "always" or "almost always" boiling their water before drinking it. Source and household drinking water samples were compared weekly for thermotolerant coliforms (TTC), an indicator of fecal contamination. Demographics, costs, and other information were collected through surveys and structured observations. Drinking water samples taken at the household (geometric mean 7.2 TTC/100 mL, 95% CI, 5.4-9.7) were actually worse in microbiological quality than source water (geometric mean 4.0 TTC/100 mL, 95% CI, 3.1-5.1) (p < 0.001), although both are relatively low levels of contamination. Only 60% of drinking water samples were reported to have actually been boiled at the time of collection from the home, suggesting over-reporting and inconsistent compliance. However, these samples were of no higher microbiological quality. Evidence suggests that water quality deteriorated after boiling due to lack of residual protection and unsafe storage and handling. The potential cost of fuel or electricity for boiling was estimated at 5% and 7% of income, respectively. In this setting where microbiological water quality was relatively good at the source, safe-storage practices that minimize recontamination may be more effective in managing the risk of disease from drinking water at a fraction of the cost of boiling.

  14. Development of a method for detecting trace metals in aqueous solutions based on the coordination chemistry of hexahydrotriazines.

    PubMed

    Wojtecki, Rudy J; Yuen, Alexander Y; Zimmerman, Thomas G; Jones, Gavin O; Horn, Hans W; Boday, Dylan J; Hedrick, James L; García, Jeannette M

    2015-08-07

    The detection of trace amounts (<10 ppb) of heavy metals in aqueous solutions is described using 1,3,5-hexahydro-1,3,5-triazines (HTs) as chemical indicators and a low cost fluorimeter-based detection system. This method takes advantage of the inherent properties of HTs to coordinate strongly with metal ions in solution, a fundamental property that was studied using a combination of analytical tools (UV-Vis titrations, (1)H-NMR titrations and computational modeling). Based on these fundamental studies that show significant changes in the HT UV signature when a metal ion is present, HT compounds were used to prepare indicator strips that resulted in significant fluorescence changes when a metal was present. A portable and economical approach was adopted to test the concept of utilizing HTs to detect heavy metals using a fluorimeter system that consisted of a low-pressure mercury lamp, a photo-detector, a monolithic photodiode and an amplifier, which produces a voltage proportional to the magnitude of the visible fluorescence emission. Readings of the prepared HT test strips were evaluated by exposure to two different heavy metals at the safe threshold concentration described by the U.S. Environmental Protection Agency (EPA) for Cr(3+) and Ag(2+) (100 μg L(-1) and 6.25, respectively). This method of detection could be used to the presence of either metal at these threshold concentrations.

  15. Low-Cost Simulation to Teach Anesthetists' Non-Technical Skills in Rwanda.

    PubMed

    Skelton, Teresa; Nshimyumuremyi, Isaac; Mukwesi, Christian; Whynot, Sara; Zolpys, Lauren; Livingston, Patricia

    2016-08-01

    Safe anesthesia care is challenging in developing countries where there are shortages of personnel, drugs, equipment, and training. Anesthetists' Non-technical Skills (ANTS)-task management, team working, situation awareness, and decision making-are difficult to practice well in this context. Cesarean delivery is the most common surgical procedure in sub-Saharan Africa. This pilot study investigates whether a low-cost simulation model, with good psychological fidelity, can be used effectively to teach ANTS during cesarean delivery in Rwanda. Study participants were anesthesia providers working in a tertiary referral hospital in Rwanda. Baseline observations were conducted for 20 anesthesia providers during cesarean delivery using the established ANTS framework. After the first observation set was complete, participants were randomly assigned to either simulation intervention or control groups. The simulation intervention group underwent ANTS training using low-cost high psychological fidelity simulation with debriefing. No training was offered to the control group. Postintervention observations were then conducted in the same manner as the baseline observations. The primary outcome was the overall ANTS score (maximum, 16). The median (range) ANTS score of the simulation group was 13.5 (11-16). The ANTS score of the control group was 8 (8-9), with a statistically significant difference (P = .002). Simulation participants showed statistically significant improvement in subcategories and in the overall ANTS score compared with ANTS score before simulation exposure. Rwandan anesthesia providers show improvement in ANTS practice during cesarean delivery after 1 teaching session using a low-cost high psychological fidelity simulation model with debriefing.

  16. Microneedle-based vaccines

    PubMed Central

    Prausnitz, Mark R.; Mikszta, John A.; Cormier, Michel; Andrianov, Alexander K.

    2010-01-01

    The threat of pandemic influenza and other public health needs motivates development of better vaccine delivery systems. To address this need, microneedles have been developed as micron-scale needles fabricated using low-cost manufacturing methods that administer vaccine into the skin using a simple device that may be suitable for self-administration. Delivery using solid or hollow microneedles can be accomplished by (i) piercing the skin and then applying a vaccine formulation or patch onto the permeabilized skin, (ii) coating or encapsulating vaccine onto or within microneedles for rapid, or delayed, dissolution and release in the skin and (iii) injection into the skin using a modified syringe or pump. Extensive clinical experience with smallpox, TB and other vaccines has shown that vaccine delivery into the skin using conventional intradermal injection is generally safe and effective and often elicits the same immune responses at lower doses compared to intramuscular injection. Animal experiments using microneedles have shown similar benefits. Microneedles have been used to deliver whole, inactivated virus; trivalent split antigen vaccines; and DNA plasmid encoding the influenza hemagglutinin to rodents and found strong antibody responses. In addition, ChimeriVax™-JE against yellow fever was administered to non-human primates and generated protective levels of neutralizing antibodies more than seven times greater than subcutaneous delivery; DNA plasmid encoding hepatitis B surface antigen was administered to mice and generated antibody and T cell responses at least as strong as hypodermic injections; recombinant Protective Antigen of Baccilus anthracis was administered to rabbits and provided complete protection from lethal aerosol anthrax spore challenge at a lower dose than intramuscular injection; and DNA plasmid encoding four vaccinia virus genes administered to mice in combination with electroporation generated neutralizing antibodies that apparently included both Th1 and Th2 responses. Dose sparing with microneedles was specifically studied in mice with the model vaccine ovalbumin. At low dose (1 µg), specific antibody titers from microneedles were one order of magnitude greater than subcutaneous injection and two orders of magnitude greater than intramuscular injection. At higher doses, antibody responses increased for all delivery methods. At the highest levels (20–80 µg), the route of administration had no significant effect on the immune response. Concerning safety, no infections or other serious adverse events have been observed in well over 1000 microneedle insertions in human and animal subjects. Bleeding generally does not occur for short microneedles (<1 mm). Highly localized, mild and transient erythema is often observed. Microneedle pain has been reported as non-existent to mild, and always much less than a hypodermic needle control. Overall, these studies suggest that microneedles may provide a safe and effective method to deliver vaccines with possible added attributes of requiring lower vaccines doses, permitting low-cost manufacturing, and enabling simple distribution and administration. PMID:19768415

  17. Long life, low cost, rechargeable AgZn battery for non-military applications

    NASA Astrophysics Data System (ADS)

    Brown, Curtis C.

    1996-03-01

    Of the rechargeable (secondary) battery systems with mature technology, the silver oxide-zinc system (AgZn) safely offers the highest power and energy (watts and watt hours) per unit of volume and mass. As a result they have long been used for aerospace and defense applications where they have also proven their high reliability. In the past, the expense associated with the cost of silver and the resulting low production volume have limited their commercial application. However, the relative low cost of silver now make this system feasible in many applications where high energy and reliability are required. One area of commercial potential is power for a new generation of sophisticated, portable medical equipment. AgZn batteries have recently proven ``enabling technology'' for power critical, advanced medical devices. By extending the cycle calendar life to the system (offers both improved performance and lower operating cost), a combination is achieved which may enable a wide range of future electrical devices. Other areas where AgZn batteries have been used in nonmilitary applications to provide power to aid in the development of commercial equipment have been: (a) Electrically powered vehicles; (b) Remote sensing in nuclear facilities; (c) Special effects equipment for movies; (d) Remote sensing in petroleum pipe lines; (e) Portable computers; (f) Fly by wire systems for commercial aircraft; and (g) Robotics. However none of these applications have progressed to the level where the volume required will significantly lower cost.

  18. Near-infrared transillumination of the maxillary sinuses: overview of methods and preliminary clinical results

    NASA Astrophysics Data System (ADS)

    Mahmood, Usama; Dehdari, Reza; Cerussi, Albert; Nguyen, Quoc; Kelley, Timothy; Tromberg, Bruce J.; Wong, Brian J.

    2005-04-01

    Though sinusitis is a significant health problem, it remains a challenging diagnosis for many physicians mainly because of its vague, non-specific symptomology. As such, physicians must often rely on x-rays and CT, which are not only costly but also expose the patient to ionizing radiation. As an alternative to these methods of diagnosis, our laboratory constructed a near infrared (NIR) transillumination system to image the paranasal maxillary sinuses. In contrast to the more conventional form of transillumination, which uses visible light, NIR transillumination uses light with a longer wavelength which is less attenuated by soft tissues, allowing increased signal intensity and tissue penetration. Our NIR transillumination system is low-cost, consisting of a light source containing two series of light emitting diodes, which give off light at wavelengths of 810 nm and 850 nm, and a charge coupled device (CCD) camera sensitive to NIR light. The light source is simply placed in the patient"s mouth and the resultant image created by the transmittance of NIR light is captured with the CCD camera via notebook PC. Using this NIR transillumination system, we imaged the paranasal maxillary sinuses of both healthy patients (n=5) and patients with sinus disease (n=12) and compared the resultant findings with conventional CT scans. We found that air and fluid/tissue-filled spaces can be reasonably distinguished by their differing NIR opacities. Based on these findings, we believe NIR transillumination of the paranasal sinuses may provide a simple, safe, and cost effective modality in the diagnosis and management of sinus disease.

  19. Efficacy of Arnica Echinacea powder in umbilical cord care in a large cohort study.

    PubMed

    Perrone, Serafina; Coppi, Silvia; Coviello, Caterina; Cecchi, Sara; Becucci, Elisa; Tataranno, Maria Luisa; Buonocore, Giuseppe

    2012-07-01

    Today healthy newborns are discharged after 48 h-72 h of life until umbilical cord (UC) detachment. Complications due to an inappropriate management are: erythema, edema, bleeding, omphalitis and sepsis. Hence the importance of a safe, effective, easy to do, and cheap method. This study tests the effects and the efficacy of arnica echinacea powder by evaluating the time of cord detachment and the risk of side effects in a large cohort of newborns. 6323 babies were treated with Arnica Echinacea powder twice a day until cord stump detachment. Medications started in hospital ward and continued at home until stump detachment. The UC stump detachment occurred in 89.09% of newborns during the first 4 days of life. This percentage increase to 96.13% at 6 days. Our study demonstrates the efficacy and the safety of arnica echinacea in UC separation. No infections or even bacterial colonizations were found. The use of arnica echinacea reduces hospital costs as a consequence of complications. In addition arnica use is well received by medical staff and parents. In conclusion due to its potential benefits, low cost and feasibility, we recommend the use of arnica echinacea powder as routine procedure in all nurseries.

  20. Green Synthesis of InP/ZnS Core/Shell Quantum Dots for Application in Heavy-Metal-Free Light-Emitting Diodes

    NASA Astrophysics Data System (ADS)

    Kuo, Tsung-Rong; Hung, Shih-Ting; Lin, Yen-Ting; Chou, Tzu-Lin; Kuo, Ming-Cheng; Kuo, Ya-Pei; Chen, Chia-Chun

    2017-09-01

    Quantum dot light-emitting diodes (QD-LEDs) have been considered as potential display technologies with the characterizations of high color purity, flexibility, transparency, and cost efficiency. For the practical applications, the development of heavy-metal-free QD-LEDs from environment-friendly materials is the most important issue to reduce the impacts on human health and environmental pollution. In this work, heavy-metal-free InP/ZnS core/shell QDs with different fluorescence were prepared by green synthesis method with low cost, safe, and environment-friendly precursors. The InP/ZnS core/shell QDs with maximum fluorescence peak at 530 nm, superior fluorescence quantum yield of 60.1%, and full width at half maximum of 55 nm were applied as an emission layer to fabricate multilayered QD-LEDs. The multilayered InP/ZnS core/shell QD-LEDs showed the turn-on voltage at 5 V, the highest luminance (160 cd/m2) at 12 V, and the external quantum efficiency of 0.223% at 6.7 V. Overall, the multilayered InP/ZnS core/shell QD-LEDs reveal potential to be the heavy-metal-free QD-LEDs for future display applications.

  1. Performance testing of collision-avoidance system for power wheelchairs.

    PubMed

    Lopresti, Edmund F; Sharma, Vinod; Simpson, Richard C; Mostowy, L Casimir

    2011-01-01

    The Drive-Safe System (DSS) is a collision-avoidance system for power wheelchairs designed to support people with mobility impairments who also have visual, upper-limb, or cognitive impairments. The DSS uses a distributed approach to provide an add-on, shared-control, navigation-assistance solution. In this project, the DSS was tested for engineering goals such as sensor coverage, maximum safe speed, maximum detection distance, and power consumption while the wheelchair was stationary or driven by an investigator. Results indicate that the DSS provided uniform, reliable sensor coverage around the wheelchair; detected obstacles as small as 3.2 mm at distances of at least 1.6 m; and attained a maximum safe speed of 4.2 km/h. The DSS can drive reliably as close as 15.2 cm from a wall, traverse doorways as narrow as 81.3 cm without interrupting forward movement, and reduce wheelchair battery life by only 3%. These results have implications for a practical system to support safe, independent mobility for veterans who acquire multiple disabilities during Active Duty or later in life. These tests indicate that a system utilizing relatively low cost ultrasound, infrared, and force sensors can effectively detect obstacles in the vicinity of a wheelchair.

  2. Reach and Cost-Effectiveness of the PrePex Device for Safe Male Circumcision in Uganda

    PubMed Central

    Duffy, Kevin; Galukande, Moses; Wooding, Nick; Dea, Monica; Coutinho, Alex

    2013-01-01

    Introduction Modelling, supported by the USAID Health Policy Initiative and UNAIDS, performed in 2011, indicated that Uganda would need to perform 4.2 million medical male circumcisions (MMCs) to reach 80% prevalence. Since 2010 Uganda has completed 380,000 circumcisions, and has set a national target of 1 million for 2013. Objective To evaluate the relative reach and cost-effectiveness of PrePex compared to the current surgical SMC method and to determine the effect that this might have in helping to achieve the Uganda national SMC targets. Methods A cross-sectional descriptive cost-analysis study conducted at International Hospital Kampala over ten weeks from August to October 2012. Data collected during the performance of 625 circumcisions using PrePex was compared to data previously collected from 10,000 circumcisions using a surgical circumcision method at the same site. Ethical approval was obtained. Results The moderate adverse events (AE) ratio when using the PrePex device was 2% and no severe adverse events were encountered, which is comparable to the surgical method, thus the AE rate has no effect on the reach or cost-effectiveness of PrePex. The unit cost to perform one circumcision using PrePex is $30.55, 35% ($7.90) higher than the current surgical method, but the PrePex method improves operator efficiency by 60%, meaning that a team can perform 24 completed circumcisions compared to 15 by the surgical method. The cost-effectiveness of PrePex, comparing the cost of performing circumcisions to the future cost savings of potentially averted HIV infections, is just 2% less than the current surgical method, at a device cost price of $20. Conclusion PrePex is a viable SMC tool for scale-up with unrivalled potential for superior reach, however national targets can only be met with effective demand creation and availability of trained human resource. PMID:23717402

  3. Leveraging community health worker system to map a mountainous rural district in low resource setting: a low-cost approach to expand use of geographic information systems for public health.

    PubMed

    Munyaneza, Fabien; Hirschhorn, Lisa R; Amoroso, Cheryl L; Nyirazinyoye, Laetitia; Birru, Ermyas; Mugunga, Jean Claude; Murekatete, Rachel M; Ntaganira, Joseph

    2014-12-06

    Geographic Information Systems (GIS) have become an important tool in monitoring and improving health services, particularly at local levels. However, GIS data are often unavailable in rural settings and village-level mapping is resource-intensive. This study describes the use of community health workers' (CHW) supervisors to map villages in a mountainous rural district of Northern Rwanda and subsequent use of these data to map village-level variability in safe water availability. We developed a low literacy and skills-focused training in the local language (Kinyarwanda) to train 86 CHW Supervisors and 25 nurses in charge of community health at the health center (HC) and health post (HP) levels to collect the geographic coordinates of the villages using Global Positioning Systems (GPS). Data were validated through meetings with key stakeholders at the sub-district and district levels and joined using ArcMap 10 Geo-processing tools. Costs were calculated using program budgets and activities' records, and compared with the estimated costs of mapping using a separate, trained GIS team. To demonstrate the usefulness of this work, we mapped drinking water sources (DWS) from data collected by CHW supervisors from the chief of the village. DWSs were categorized as safe versus unsafe using World Health Organization definitions. Following training, each CHW Supervisor spent five days collecting data on the villages in their coverage area. Over 12 months, the CHW supervisors mapped the district's 573 villages using 12 shared GPS devices. Sector maps were produced and distributed to local officials. The cost of mapping using CHW supervisors was $29,692, about two times less than the estimated cost of mapping using a trained and dedicated GIS team ($60,112). The availability of local mapping was able to rapidly identify village-level disparities in DWS, with lower access in populations living near to lakes and wetlands (p < .001). Existing national CHW system can be leveraged to inexpensively and rapidly map villages even in mountainous rural areas. These data are important to provide managers and decision makers with local-level GIS data to rapidly identify variability in health and other related services to better target and evaluate interventions.

  4. Using Ensemble Decisions and Active Selection to Improve Low-Cost Labeling for Multi-View Data

    NASA Technical Reports Server (NTRS)

    Rebbapragada, Umaa; Wagstaff, Kiri L.

    2011-01-01

    This paper seeks to improve low-cost labeling in terms of training set reliability (the fraction of correctly labeled training items) and test set performance for multi-view learning methods. Co-training is a popular multiview learning method that combines high-confidence example selection with low-cost (self) labeling. However, co-training with certain base learning algorithms significantly reduces training set reliability, causing an associated drop in prediction accuracy. We propose the use of ensemble labeling to improve reliability in such cases. We also discuss and show promising results on combining low-cost ensemble labeling with active (low-confidence) example selection. We unify these example selection and labeling strategies under collaborative learning, a family of techniques for multi-view learning that we are developing for distributed, sensor-network environments.

  5. Comparative Evaluation of Fluoridated Mouthwash and Sodium Bicarbonate in Management of Dentin Hypersensitivity: An In Vitro SEM Study.

    PubMed

    Rikame, Vasundhara; Doshi, Yogesh; Horowitz, Robert A; Kevadia-Shah, Vidhi; Shah, Mona

    2018-01-01

    Sodium bicarbonate (ie, baking soda) can be used as an adjunct to surgical periodontal therapy to reduce dentin hypersensitivity (DH). Sodium bicarbonate mouthwash has numerous appealing attributes, including high availability, low cost, low abrasivity, water solubility, buffering capability, and, in high concentrations, antimicrobial properties. It is also safe to use. The primary underlying cause of DH is open dentinal tubules from loss of either cementum or enamel. The aim of this in vitro study was to evaluate, through scanning electron microscopic examination, the effect of sodium bicarbonate on dentinal tubule occlusion and compare it with that of fluoridated mouthwash.

  6. Benefits of advanced space suits for supporting routine extravehicular activity

    NASA Technical Reports Server (NTRS)

    Alton, L. R.; Bauer, E. H.; Patrick, J. W.

    1975-01-01

    Technology is available to produce space suits providing a quick-reaction, safe, much more mobile extravehicular activity (EVA) capability than before. Such a capability may be needed during the shuttle era because the great variety of missions and payloads complicates the development of totally automated methods of conducting operations and maintenance and resolving contingencies. Routine EVA now promises to become a cost-effective tool as less complex, serviceable, lower-cost payload designs utilizing this capability become feasible. Adoption of certain advanced space suit technologies is encouraged for reasons of economics as well as performance.

  7. KSC-2013-1052

    NASA Image and Video Library

    2013-01-09

    CAPE CANAVERAL, Fla. -- At a news conference NASA officials and industry partners discuss progress of the agency's Commercial Crew Program. Among those participating in the briefing is Garrett Reisman, Space Exploration Technologies SpaceX Commercial Crew project manager. Through CCP, NASA is facilitating the development of U.S. commercial crew space transportation capabilities to achieve safe, reliable and cost-effective access to and from low-Earth orbit for potential future government and commercial customers. For more information, visit http://www.nasa.gov/commercialcrew Photo credit: NASA/Kim Shiflett

  8. Flight test and evaluation of Omega navigation for general aviation

    NASA Technical Reports Server (NTRS)

    Hwoschinsky, P. V.

    1975-01-01

    A seventy hour flight test program was performed to determine the suitability and accuracy of a low cost Omega navigation receiver in a general aviation aircraft. An analysis was made of signal availability in two widely separated geographic areas. Comparison is made of the results of these flights with other navigation systems. Conclusions drawn from the test experience indicate that developmental system improvement is necessary before a competent fail safe or fail soft area navigation system is offered to general aviation.

  9. Pulmonary Nodule Management in Lung Cancer Screening: A Pictorial Review of Lung-RADS Version 1.0.

    PubMed

    Godoy, Myrna C B; Odisio, Erika G L C; Truong, Mylene T; de Groot, Patricia M; Shroff, Girish S; Erasmus, Jeremy J

    2018-05-01

    The number of screening-detected lung nodules is expected to increase as low-dose computed tomography screening is implemented nationally. Standardized guidelines for image acquisition, interpretation, and screen-detected nodule workup are essential to ensure a high standard of medical care and that lung cancer screening is implemented safely and cost effectively. In this article, we review the current guidelines for pulmonary nodule management in the lung cancer screening setting. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Micro-pulse, differential absorption lidar (dial) network for measuring the spatial and temporal distribution of water vapor in the lower atmosphere

    NASA Astrophysics Data System (ADS)

    Spuler, Scott; Repasky, Kevin; Hayman, Matt; Nehrir, Amin

    2018-04-01

    The National Center for Atmospheric Research (NCAR) and Montana State Univeristy (MSU) are developing a test network of five micro-pulse differential absorption lidars to continuously measure high-vertical-resolution water vapor in the lower atmosphere. The instruments are accurate, yet low-cost; operate unattended, and eye-safe - all key features to enable the larger network needed to characterize atmospheric moisture variability which influences important processes related to weather and climate.

  11. KSC-2013-1049

    NASA Image and Video Library

    2013-01-09

    CAPE CANAVERAL, Fla. -- At a news conference NASA officials and industry partners discuss progress of the agency's Commercial Crew Program. Among those participating in the briefing is Rob Meyerson, Blue Origin president and program manager. Through CCP, NASA is facilitating the development of U.S. commercial crew space transportation capabilities to achieve safe, reliable and cost-effective access to and from low-Earth orbit for potential future government and commercial customers. For more information, visit http://www.nasa.gov/commercialcrew Photo credit: NASA/Kim Shiflett

  12. Crew Transportation Plan

    NASA Technical Reports Server (NTRS)

    Zeitler, Pamela S. (Compiler); Mango, Edward J.

    2013-01-01

    The National Aeronautics and Space Administration (NASA) Commercial Crew Program (CCP) has been chartered to facilitate the development of a United States (U.S.) commercial crew space transportation capability with the goal of achieving safe, reliable, and cost effective access to and from low Earth orbit (LEO) and the International Space Station (ISS) as soon as possible. Once the capability is matured and is available to the Government and other customers, NASA expects to purchase commercial services to meet its ISS crew rotation and emergency return objectives.

  13. A Carbon Nanotube Pillar Array Ionizer for Miniature Ion Thruster Applications

    DTIC Science & Technology

    2008-12-01

    interest in using argon as a propellant. The advantages of argon go beyond its low cost to include its inertness, which makes it safe to handle and...They can be formed either as single- walled structures (SWCNTs), as shown in Figure 5, or as multi-walled structures ( MWCNTs ), as shown in Figure 6...The structure in Figure 6 is known as a Russian Doll MWCNT due to its structure of concentric individual CNTs. There is another type of MWCNT known

  14. Sterilizable syringes: excessive risk or cost-effective option?

    PubMed Central

    Battersby, A.; Feilden, R.; Nelson, C.

    1999-01-01

    In recent years, many poorer countries have chosen to use disposable instead of sterilizable syringes. Unfortunately, the infrastructure and management systems that are vital if disposables are to be used safely do not exist. WHO estimates that up to 30% of injections administered are unsafe. The traditional sterilizable syringe had many disadvantages, some of which have been minimized through better design and the use of modern materials; others have been overcome because staff are able to demonstrate that they have performed safely. For example, the time-steam saturation-temperature (TST) indicator has enabled staff to demonstrate that a sterilizing cycle has been successfully completed. Health facility staff must be able to sterilize equipment, and the sterilizable syringe remains the least costly means of administering an injection. Data from countries that have acceptable systems for processing clinical waste indicate that safe and environmentally acceptable disposal, destruction and final containment cost nearly as much as the original cost of a disposable syringe. By careful supervision of staff behaviour and good management, some countries have demonstrated that they are able to administer safe injections with sterilizable syringes at a price they can afford. PMID:10593029

  15. Damage accumulation in closed cross-section, laminated, composite structures

    NASA Technical Reports Server (NTRS)

    Bucinell, Ronald B.

    1996-01-01

    The need for safe, lightweight, less expensive, and more reliable launch vehicle components is being driven by the competitiveness of the commercial launch market. The United States has lost 2/3 of the commercial lunch market to Europe. As low cost Russian and Chinese vehicles become available, the US market share could be reduced even further. This international climate is driving the Single Stage To Orbit (SSTO) program at NASA. The goal of the SSTO program is to radically reduce the cost of safe, routine transportation to and from space with a totally reusable launch vehicle designed for low-cost aircraft-like operations. Achieving this goal will require more efficient uses of materials. Composite materials can provide this program with the material and structural efficiencies needed to stay competitive in the international launch market place. In satellite systems the high specific properties, design flexibility, improved corrosion and wear resistance, increased fatigue life, and low coefficient of thermal expansion that are characteristic of composite materials can all be used to improve the overall satellite performance. Some of the satellites that may be able to take advantage of these performance characteristics are the Tethered Satellite Systems (TOSCIFER, AIRSEDS, TSS2, SEDS1, and SEDS2), AXAF, GRO, and the next generation Hubble Space Telescope. These materials can also be utilized in projects at the NASAIMSFC Space Optics Technology and System Center of Excellence. The successful implementation of composite materials requires accurate performance characterization. Materials characterization data for composite materials is typically generated using flat coupons of finite width. At the free edge of these coupons the stress state is exacerbated by the presence of stiffness and geometric discontinuities. The exacerbated stress state has been shown to dominate the damage accumulation in these materials and to have a profound affect on the material constants. Space structures typically have closed cross-sections, absent of free edges. As a result, composite material characterization data generated using finite width flat specimens does not accurately reflect the performance of the composite materials used in a closed cross-section structural configuration. Several investigators have recognized the need to develop characterization techniques for composite materials in closed cross-sectioned structures. In these investigations test methods were developed and cylindrical specimens were evaluated. The behavior of the cylindrical specimens were observed to depart from behavior typical of flat coupons. However, no attempts were made to identify and monitor the progression of damage in these cylindrical specimens during loading. The identification and monitoring of damage is fundamental to the characterization of composite materials in closed cross-section configurations. In the study reported here, a closed cross-sectioned test method was developed to monitor damage progression in 2 in. diameter cylindrical specimens and 1.5 in. finite width flat coupons subjected to quasi-static, tensile loading conditions. Damage in these specimen configurations was monitored using pulse echo ultrasonic, acoustic emission, and X-ray techniques.

  16. Potential public sector cost-savings from over-the-counter access to oral contraceptives.

    PubMed

    Foster, Diana G; Biggs, M Antonia; Phillips, Kathryn A; Grindlay, Kate; Grossman, Daniel

    2015-05-01

    This study estimates how making oral contraceptive pills (OCPs) available without a prescription may affect contraceptive use, unintended pregnancies and associated contraceptive and pregnancy costs among low-income women. Based on published figures, we estimate two scenarios [low over-the-counter (OTC) use and high OTC use] of the proportion of low-income women likely to switch to an OTC pill and predict adoption of OCPs according to the out-of-pocket costs per pill pack. We then estimate cost-savings of each scenario by comparing the total public sector cost of providing OCPs OTC and medical care for unintended pregnancy. Twenty-one percent of low-income women at risk for unintended pregnancy are very likely to use OCPs if they were available without a prescription. Women's use of OTC OCPs varies widely by the out-of-pocket pill pack cost. In a scenario assuming no out-of-pocket costs for the over-the counter pill, an additional 11-21% of low-income women will use the pill, resulting in a 20-36% decrease in the number of women using no method or a method less effective than the pill, and a 7-25% decrease in the number of unintended pregnancies, depending on the level of use and any effect on contraceptive failure rates. If out-of-pocket costs for such pills are low, OTC access could have a significant effect on use of effective contraceptives and unintended pregnancy. Public health plans may reduce expenditures on pregnancy and contraceptive healthcare services by covering oral contraceptives as an OTC product. Interest in OTC access to oral contraceptives is high. Removing the prescription barrier, particularly if pill packs are available at low or zero out-of-pocket cost, could increase the use of effective methods of contraception and reduce unintended pregnancy and healthcare costs for contraceptive and pregnancy care. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Using the Method of Water Poverty Index (WPI) to Evaluate the Region Water Security

    NASA Astrophysics Data System (ADS)

    Fu, Q.; Kachanoski, G.

    2008-12-01

    Water security is a widely concerned issue in the world nowadays. A new method, water poverty index (WPI), has been used to evaluate the regional water security. Twelve state farms in Heilongjiang Province, Northeastern China were selected to evaluate water security status based on the data of 2006 by using WPI and mean deviation grading method. The method of WPI includes five key indexes, such as resources(R), access (A), capacity(C), utilization (U) and environment (E). Each key index includes several sub-indexes. According to the results of WPI, the grade of each farm has been calculated by using the method of mean deviation grading. Thus, the radar images can be protracted of each farm. From the radar images, the conclusions can be drawn that the WPI values of Farms 853 and Hongqiling were in very safe status, while that of Farm Raohe was in safe status, those of Farms Youyi, 597, 852, 291 and Jiangchuan were in moderate safe status, that of Farm Beixing was in low safe status and those of Farms Shuangyashan, Shuguang and Baoshan were in unsafe status. The results from this study can provide basic information for decision making on rational use of water resources and regulations for regional water safety guarantee system.

  18. pH manipulation as a novel strategy for treating mucormycosis.

    PubMed

    Trzaska, Wioleta J; Correia, Joao N; Villegas, Maria T; May, Robin C; Voelz, Kerstin

    2015-11-01

    Mucormycosis is a fatal fungal disease caused by several organisms within the order Mucorales. In recent years, traumatic injury has emerged as a novel risk factor for mucormycosis. Current antifungal therapy is ineffective, expensive, and typically requires extensive surgical debridement. There is thus a pressing need for safe prophylactic treatment that can be rapidly and easily applied to high-risk patients, such as those with major trauma injuries. Acetic acid has been used as a topical treatment for burn wounds for centuries and has proven activity against Gram-negative bacteria. Here, we demonstrate that acetic acid is also highly effective against major pathogenic groups of Mucorales, even at very low concentrations (0.3%). This antifungal effect is not seen with other acids, such as hydrochloric and lactic acid, suggesting that acetic acid activity against Mucorales spores is not solely evoked by low environmental pH. In agreement with this, we demonstrate that the antifungal activity of acetic acid arises from a combination of its ability to potently lower intracellular pH and from pH-independent toxicity. Thus, dilute acetic acid may offer a low-cost, safe, prophylactic treatment for patients at risk of invasive mucormycosis following traumatic injury. Copyright © 2015, Trzaska et al.

  19. Development of a novel in-water vaccination protocol for DNA adenine methylase deficient Salmonella enterica serovar Typhimurium vaccine in adult sheep.

    PubMed

    Mohler, V L; Heithoff, D M; Mahan, M J; Hornitzky, M A; Thomson, P C; House, J K

    2012-02-14

    Intensive livestock production is associated with an increased incidence of salmonellosis. The risk of infection and the subsequent public health concern is attributed to increased pathogen exposure and disease susceptibility due to multiple stressors experienced by livestock from farm to feedlot. Traditional parenteral vaccine methods can further stress susceptible populations and cause carcass damage, adverse reactions, and resultant increased production costs. As a potential means to address these issues, in-water delivery of live attenuated vaccines affords a low cost, low-stress method for immunization of livestock populations that is not associated with the adverse handling stressors and injection reactions associated with parenteral administration. We have previously established that in-water administration of a Salmonella enterica serovar Typhimurium dam vaccine conferred significant protection in livestock. While these experimental trials hold significant promise, the ultimate measure of the vaccine will not be established until it has undergone clinical testing in the field wherein environmental and sanitary conditions are variable. Here we show that in-water administration of a S. Typhimurium dam attenuated vaccine was safe, stable, and well-tolerated in adult sheep. The dam vaccine did not alter water consumption or vaccine dosing; remained viable under a wide range of temperatures (21-37°C); did not proliferate within fecal-contaminated trough water; and was associated with minimal fecal shedding and clinical disease as a consequence of vaccination. The capacity of Salmonella dam attenuated vaccines to be delivered in drinking water to protect livestock from virulent Salmonella challenge offers an effective, economical, stressor-free Salmonella prophylaxis for intensive livestock production systems. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Facility Systems, Ground Support Systems, and Ground Support Equipment General Design Requirements

    NASA Technical Reports Server (NTRS)

    Thaxton, Eric A.; Mathews, Roger E.

    2014-01-01

    This standard establishes requirements and guidance for design and fabrication of ground systems (GS) that includes: ground support equipment (GSE), ground support systems (GSS), and facility ground support systems (F GSS) to provide uniform methods and processes for design and development of robust, safe, reliable, maintainable, supportable, and cost-effective GS in support of space flight and institutional programs and projects.

  1. SOGC–GOC–SCC Joint Policy Statement. No. 255, March 2011. Cervical cancer prevention in low-resource settings.

    PubMed

    Elit, Laurie; Jimenez, Waldo; McAlpine, Jessica; Ghatage, Prafull; Miller, Dianne; Plante, Marie

    2011-03-01

    To help care providers understand the current status of cervical cancer in low-resource countries. The most effective and practical options for cervical screening and treatment in low-resource countries are evaluated. Improvement in rates of prevention and early detection of cervical cancer in low-resource countries. PubMed or Medline, CINAHL, and The Cochrane Library were searched for studies published in English between January 2006 and December 2009. Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Grey (unpublished) literature was identified through searching the websites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care. Recommendations for practice were ranked according to the method described in that report (Table). RECOMMENDATIONS 1. All girls 9 years old or over should have access to the cervical cancer vaccine before they become sexually active. (I-A) 2. Cervical cancer screening by visual inspection with acetic acid is suggested for low-resource settings acceptable. Cervical cytology or human papillomavirus testing may also be used when practical. (II-2B) 3. Cryotherapy is a safe, effective, and low-cost therapy that should be included in pre-invasive cervical cancer treatment. (III-B) 4. All countries should have a documented cervical cancer prevention strategy that includes public education built on existing outreach programs. (III-C) 5. Countries should define a centre or centres of excellence for the management of cervical cancer. (III-C) Because these units would serve a larger population, they would be able to identify leaders and develop their skills, and would be able to invest in costly radiation equipment. 6. All women with cervical cancer should have access to pain management. (III-C).

  2. Feasibility of the hydrogen sulfide test for the assessment of drinking water quality in post-earthquake Haiti.

    PubMed

    Weppelmann, Thomas A; Alam, Meer T; Widmer, Jocelyn; Morrissey, David; Rashid, Mohammed H; De Rochars, Valery M Beau; Morris, J Glenn; Ali, Afsar; Johnson, Judith A

    2014-12-01

    In 2010, a magnitude 7.0 earthquake struck Haiti, severely damaging the drinking and wastewater infrastructure and leaving millions homeless. Compounding this problem, the introduction of Vibrio cholerae resulted in a massive cholera outbreak that infected over 700,000 people and threatened the safety of Haiti's drinking water. To mitigate this public health crisis, non-government organizations installed thousands of wells to provide communities with safe drinking water. However, despite increased access, Haiti currently lacks the monitoring capacity to assure the microbial safety of any of its water resources. For these reasons, this study was designed to assess the feasibility of using a simple, low-cost method to detect indicators of fecal contamination of drinking water that could be implemented at the community level. Water samples from 358 sources of drinking water in the Léogâne flood basin were screened with a commercially available hydrogen sulfide test and a standard membrane method for the enumeration of thermotolerant coliforms. When compared with the gold standard method, the hydrogen sulfide test had a sensitivity of 65 % and a specificity of 93 %. While the sensitivity of the assay increased at higher fecal coliform concentrations, it never exceeded 88 %, even with fecal coliform concentrations greater than 100 colony-forming units per 100 ml. While its simplicity makes the hydrogen sulfide test attractive for assessing water quality in low-resource settings, the low sensitivity raises concerns about its use as the sole indicator of the presence or absence of fecal coliforms in individual or community water sources.

  3. Feasibility of the Hydrogen Sulfide Test for the Assessment of Drinking Water Quality in Post-Earthquake Haiti

    PubMed Central

    Weppelmann, Thomas A.; Alam, Meer T.; Widmer, Jocelyn; Morrissey, David; Rashid, Mohammed H.; Beau De Rochars, Valery M.; Morris, J. Glenn; Ali, Afsar; Johnson, Judith A.

    2014-01-01

    In 2010 a magnitude 7.0 earthquake struck Haiti, severely damaging the drinking and waste water infrastructure and leaving millions homeless. Compounding this problem, the introduction of Vibrio cholera resulted in a massive cholera outbreak that infected over 700,000 people and threatened the safety of Haiti’s drinking water. To mitigate this public health crisis, non-government organizations installed thousands of wells to provide communities with safe drinking water. However, despite increased access, Haiti currently lacks the monitoring capacity to assure the microbial safety of any of its water resources. For these reasons, this study was designed to assess the feasibility of using a simple, low cost method to detect indicators of fecal contamination of drinking water that could be implemented at the community level. Water samples from 358 sources of drinking water in the Léogâne flood basin were screened with a commercially available hydrogen sulfide test and a standard membrane method for the enumeration of thermotolerant coliforms. When compared with the gold standard method, the hydrogen sulfide test had a sensitivity of 65% and a specificity of 93%. While the sensitivity of the assay increased at higher fecal coliform concentrations, it never exceeded 88%, even with fecal coliform concentrations greater than 100 colony forming units per 100 milliliters. While its simplicity makes the hydrogen sulfide test attractive for assessing water quality in low resource settings, the low sensitivity raises concerns about its use as the sole indicator of the presence or absence of fecal coliforms in individual or community water sources. PMID:25182685

  4. The Potential Power of Bar-HRM Technology in Herbal Medicine Identification

    PubMed Central

    Sun, Wei; Li, Jing-jian; Xiong, Chao; Zhao, Bo; Chen, Shi-lin

    2016-01-01

    The substitution of low-cost or adulterated herbal products for high-priced herbs makes it important to be able to identify and trace herbal plant species and their processed products in the drug supply chain. PCR-based methods play an increasing role in monitoring the safety of herbal medicines by detecting adulteration. Recent studies have shown the potential of DNA barcoding combined with high resolution melting (Bar-HRM) analysis in herbal medicine identification. This method involves precisely monitoring the change in fluorescence caused by the release of an intercalating DNA dye from a DNA duplex as it is denatured by a gradual increase in temperature. Since the melting profile depends on the GC content, length, and strand complementarity of the amplification product, Bar-HRM analysis opens up the possibility of detecting single-base variants or species-specific differences in a short region of DNA. This review summarizes key factors affecting Bar-HRM analysis and describes how Bar-HRM is performed. We then discuss advances in Bar-HRM analysis of medicinal plant ingredients (herbal materia medica) as a contribution toward safe and effective herbal medicines. PMID:27066026

  5. The Potential Power of Bar-HRM Technology in Herbal Medicine Identification.

    PubMed

    Sun, Wei; Li, Jing-Jian; Xiong, Chao; Zhao, Bo; Chen, Shi-Lin

    2016-01-01

    The substitution of low-cost or adulterated herbal products for high-priced herbs makes it important to be able to identify and trace herbal plant species and their processed products in the drug supply chain. PCR-based methods play an increasing role in monitoring the safety of herbal medicines by detecting adulteration. Recent studies have shown the potential of DNA barcoding combined with high resolution melting (Bar-HRM) analysis in herbal medicine identification. This method involves precisely monitoring the change in fluorescence caused by the release of an intercalating DNA dye from a DNA duplex as it is denatured by a gradual increase in temperature. Since the melting profile depends on the GC content, length, and strand complementarity of the amplification product, Bar-HRM analysis opens up the possibility of detecting single-base variants or species-specific differences in a short region of DNA. This review summarizes key factors affecting Bar-HRM analysis and describes how Bar-HRM is performed. We then discuss advances in Bar-HRM analysis of medicinal plant ingredients (herbal materia medica) as a contribution toward safe and effective herbal medicines.

  6. 24 CFR 221.275 - Method of paying insurance benefits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AUTHORITIES LOW COST AND MODERATE INCOME MORTGAGE INSURANCE-SAVINGS CLAUSE Contract Rights and Obligations-Low Cost Homes § 221.275 Method of paying insurance benefits. If the application for insurance benefits is acceptable to the Commissioner, all of the insurance claim shall be paid in cash unless the mortgagee files a...

  7. Testing Of An Ultraviolet (UV)-Transparent Polymer-Based Passive Sampler for Rapid, Ultra-Low-Cost EDC Screening Applications

    EPA Science Inventory

    A new passive sampling method with rapid low-cost spectral detection has recently been developed. The method makes use of an ultraviolet (UV)-transparent polymer which serves as both a concentrator for dissolved compounds, and an optical cell for UV spectral detection. Because ...

  8. An objective and cross-sectional examination of sun-safe behaviours in New South Wales primary schools.

    PubMed

    Dudley, Dean A; Cotton, Wayne G; Winslade, Matthew J; Wright, Bradley J; Jackson, Kirsten S; Brown, Alexandra M; Rock, Vanessa

    2017-01-05

    Previous evaluations have supported the link between sun protection policies and improved sun protection behaviours. However these evaluations have relied on self-reported data. A cross-sectional design as part of an ongoing 18-month cluster-controlled trial in primary schools (n = 20) was used. Researchers conducted direct observations to record students' hat use and teachers' use of sun protective measures during recess and lunch. Researchers also recorded the volume of sunscreen consumed in each school. Only 60% of primary school children wear a sun-safe hat during their breaks when observed using objective measures. Weak correlations were observed between the wearing of a sun-safe hat and a school's socio-economic status (r = 0.26). All other independent variables measured had only very weak correlations (r < 0.19) with sun-safe hat wearing behaviour of students. Sunscreen consumption by school students during the school day is negligible. A large percentage of NSW primary schools in this study wear sun-safe hats during the school day but this is well below what has been reported in previous national surveys. Given the finite resources of schools and the correlation, though small, with SES status for these behaviours, it behoves researchers to investigate low-cost solutions to these problems. Further qualitative data will also be needed to inform the enablers and barriers for sun-safe behaviour interventions to be adopted in NSW primary schools.

  9. Evolution of Safety Analysis to Support New Exploration Missions

    NASA Technical Reports Server (NTRS)

    Thrasher, Chard W.

    2008-01-01

    NASA is currently developing the Ares I launch vehicle as a key component of the Constellation program which will provide safe and reliable transportation to the International Space Station, back to the moon, and later to Mars. The risks and costs of the Ares I must be significantly lowered, as compared to other manned launch vehicles, to enable the continuation of space exploration. It is essential that safety be significantly improved, and cost-effectively incorporated into the design process. This paper justifies early and effective safety analysis of complex space systems. Interactions and dependences between design, logistics, modeling, reliability, and safety engineers will be discussed to illustrate methods to lower cost, reduce design cycles and lessen the likelihood of catastrophic events.

  10. Sensitivity Analysis and Mitigation with Applications to Ballistic and Low-thrust Trajectory Design

    NASA Astrophysics Data System (ADS)

    Alizadeh, Iman

    The ever increasing desire to expand space mission capabilities within the limited budgets of space industries requires new approaches to the old problem of spacecraft trajectory design. For example, recent initiatives for space exploration involve developing new tools to design low-cost, fail-safe trajectories to visit several potential destinations beyond our celestial neighborhood such as Jupiter's moons, asteroids, etc. Designing and navigating spacecraft trajectories to reach these destinations safely are complex and challenging. In particular, fundamental questions of orbital stability imposed by planetary protection requirements are not easily taken into account by standard optimal control schemes. The event of temporary engine loss or an unexpected missed thrust can indeed quickly lead to impact with planetary bodies or other unrecoverable trajectories. While electric propulsion technology provides superior efficiency compared to chemical engines, the very low-control authority and engine performance degradation can impose higher risk to the mission in strongly perturbed orbital environments. The risk is due to the complex gravitational field and its associated chaotic dynamics which causes large navigation dispersions in a short time if left un-controlled. Moreover, in these situations it can be outside the low-thrust propulsion system capability to correct the spacecraft trajectory in a reasonable time frame. These concerns can lead to complete or partial mission failure or even an infeasible mission concept at the early design stage. The goal of this research is to assess and increase orbital stability of ballistic and low-thrust transfer trajectories in multi-body systems. In particular, novel techniques are presented to characterize sensitivity and improve recovery characteristics of ballistic and low-thrust trajectories in unstable orbital environments. The techniques developed are based on perturbation analysis around ballistic trajectories to determine analytically the maximum divergence directions and also optimal control theory with nonstandard cost functions along with inverse dynamics applied to low-thrust trajectories. Several mission scenarios are shown to demonstrate the applicability of the techniques in the Earth-Moon and the Jupiter-Europa system. In addition, the results provide fundamental insight into design, stability analysis and guidance, navigation and control of low-thrust trajectories to meet challenging mission requirements in support of NASA's vision for space exploration.

  11. Feasibility of incorporating functionally relevant virtual rehabilitation in sub-acute stroke care: perception of patients and clinicians.

    PubMed

    Demers, Marika; Chan Chun Kong, Daniel; Levin, Mindy F

    2018-03-11

    To determine user satisfaction and safety of incorporating a low-cost virtual rehabilitation intervention as an adjunctive therapeutic option for cognitive-motor upper limb rehabilitation in individuals with sub-acute stroke. A low-cost upper limb virtual rehabilitation application incorporating realistic functionally-relevant unimanual and bimanual tasks, specifically designed for cognitive-motor rehabilitation was developed for patients with sub-acute stroke. Clinicians and individuals with stroke interacted with the intervention for 15-20 or 20-45 minutes, respectively. The study had a mixed-methods convergent parallel design that included a focus group interview with clinicians working in a stroke program and semi-structured interviews and standardized assessments (Borg Perceived Exertion Scale, Short Feedback Questionnaire) for participants with sub-acute stroke undergoing rehabilitation. The occurrence of adverse events was also noted. Three main themes emerged from the clinician focus group and patient interviews: Perceived usefulness in rehabilitation, satisfaction with the virtual reality intervention and aspects to improve. All clinicians and the majority of participants with stroke were highly satisfied with the intervention and perceived its usefulness to decrease arm motor impairment during functional tasks. No participants experienced major adverse events. Incorporation of this type of functional activity game-based virtual reality intervention in the sub-acute phase of rehabilitation represents a way to transfer skills learned early in the clinical setting to real world situations. This type of intervention may lead to better integration of the upper limb into everyday activities. Implications for Rehabilitation • Use of a cognitive-motor low-cost virtual reality intervention designed to remediate arm motor impairments in sub-acute stroke is feasible, safe and perceived as useful by therapists and patients for stroke rehabilitation.    • Input from end-users (therapists and individuals with stroke) is critical for the development and implementation of a virtual reality intervention.

  12. Pre-exposure rabies prophylaxis: a systematic review

    PubMed Central

    Recuenco, Sergio; Navarro-Vela, Ana Maria; Deray, Raffy; Vigilato, Marco; Ertl, Hildegund; Durrheim, David; Rees, Helen; Nel, Louis H; Abela-Ridder, Bernadette; Briggs, Deborah

    2017-01-01

    Abstract Objective To review the safety and immunogenicity of pre-exposure rabies prophylaxis (including accelerated schedules, co-administration with other vaccines and booster doses), its cost–effectiveness and recommendations for use, particularly in high-risk settings. Methods We searched the PubMed, Centre for Agriculture and Biosciences International, Cochrane Library and Web of Science databases for papers on pre-exposure rabies prophylaxis published between 2007 and 29 January 2016. We reviewed field data from pre-exposure prophylaxis campaigns in Peru and the Philippines. Findings Pre-exposure rabies prophylaxis was safe and immunogenic in children and adults, also when co-administered with routine childhood vaccinations and the Japanese encephalitis vaccine. The evidence available indicates that shorter regimens and regimens involving fewer doses are safe and immunogenic and that booster intervals could be extended up to 10 years. The few studies on cost suggest that, at current vaccine and delivery costs, pre-exposure prophylaxis campaigns would not be cost-effective in most situations. Although pre-exposure prophylaxis has been advocated for high-risk populations, only Peru and the Philippines have implemented appropriate national programmes. In the future, accelerated regimens and novel vaccines could simplify delivery and increase affordability. Conclusion Pre-exposure rabies prophylaxis is safe and immunogenic and should be considered: (i) where access to postexposure prophylaxis is limited or delayed; (ii) where the risk of exposure is high and may go unrecognized; and (iii) where controlling rabies in the animal reservoir is difficult. Pre-exposure prophylaxis should not distract from canine vaccination efforts, provision of postexposure prophylaxis or education to increase rabies awareness in local communities. PMID:28250534

  13. Liquid scintillator composition optimization for use in ultra-high energy cosmic ray detector systems

    NASA Astrophysics Data System (ADS)

    Beznosko, Dmitriy; Batyrkhanov, Ayan; Iakovlev, Alexander; Yelshibekov, Khalykbek

    2017-06-01

    The Horizon-T (HT) detector system and the currently under R&D HT-KZ detector system are designed for the detection of Extensive Air Showers (EAS) with energies above ˜1016 eV (˜1017 eV for HT-KZ). The main challenges in both detector systems are the fast time resolutions needed for studying the temporary structure of EAS, and the extremely wide dynamic range needed to study the spatial distribution of charged particles in EAS disks. In order to detect the low-density of charged particles far from the EAS axis, a large-area detector is needed. Liquid scintillator with low cost would be a possible solution for such a detector, including the recently developed safe and low-cost water-based liquid scintillators. Liquid organic scintillators give a fast and high light yield (LY) for charged particle detection. It is similar to plastic scintillator in properties but is cost effective for large volumes. With liquid scintillator, one can create detection volumes that are symmetric and yet retain high LY detection. Different wavelength shifters affect the scintillation light by changing the output spectrum into the best detection region. Results of the latest studies of the components optimization in the liquid scintillator formulae are presented.

  14. Design and development of a low-cost biphasic charge-balanced functional electric stimulator and its clinical validation.

    PubMed

    Shendkar, Chandrashekhar; Lenka, Prasanna K; Biswas, Abhishek; Kumar, Ratnesh; Mahadevappa, Manjunatha

    2015-10-01

    Functional electric stimulators that produce near-ideal, charge-balanced biphasic stimulation waveforms with interphase delay are considered safer and more efficacious than conventional stimulators. An indigenously designed, low-cost, portable FES device named InStim is developed. It features a charge-balanced biphasic single channel. The authors present the complete design, mathematical analysis of the circuit and the clinical evaluation of the device. The developed circuit was tested on stroke patients affected by foot drop problems. It was tested both under laboratory conditions and in clinical settings. The key building blocks of this circuit are low dropout regulators, a DC-DC voltage booster and a single high-power current source OP-Amp with current-limiting capabilities. This allows the device to deliver high-voltage, constant current, biphasic pulses without the use of a bulky step-up transformer. The advantages of the proposed design over the currently existing devices include improved safety features (zero DC current, current-limiting mechanism and safe pulses), waveform morphology that causes less muscle fatigue, cost-effectiveness and compact power-efficient circuit design with minimal components. The device is also capable of producing appropriate ankle dorsiflexion in patients having foot drop problems of various Medical Research Council scale grades.

  15. Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools.

    PubMed

    Sá, Juliana P; Branco, Pedro T B S; Alvim-Ferraz, Maria C M; Martins, Fernando G; Sousa, Sofia I V

    2017-05-31

    Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO₂, CO, NO₂, O₃, CH₂O, total volatile organic compounds (VOC), PM₁, PM 2.5 , PM 10 , Total Suspended Particles (TSP) and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO) were found for PM 2.5 , PM 10 , CO₂ and CH₂O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO₂. However, mitigation measures were not always sufficient to decrease the pollutants' concentrations till values considered safe to protect human health.

  16. Clinical and cost-effectiveness of non-medical prescribing: A systematic review of randomised controlled trials

    PubMed Central

    Marriott, John; Graham-Clarke, Emma; Shirley, Debra; Rushton, Alison

    2018-01-01

    Objective To evaluate the clinical and cost-effectiveness of non-medical prescribing (NMP). Design Systematic review. Two reviewers independently completed searches, eligibility assessment and assessment of risk of bias. Data sources Pre-defined search terms/combinations were utilised to search electronic databases. In addition, hand searches of reference lists, key journals and grey literature were employed alongside consultation with authors/experts. Eligibility criteria for included studies Randomised controlled trials (RCTs) evaluating clinical or cost-effectiveness of NMP. Measurements reported on one or more outcome(s) of: pain, function, disability, health, social impact, patient-safety, costs-analysis, quality adjusted life years (QALYs), patient satisfaction, clinician perception of clinical and functional outcomes. Results Three RCTs from two countries were included (n = 932 participants) across primary and tertiary care settings. One RCT was assessed as low risk of bias, one as high risk of bias and one as unclear risk of bias. All RCTs evaluated clinical effectiveness with one also evaluating cost-effectiveness. Clinical effectiveness was evaluated using a range of safety and patient-reported outcome measures. Participants demonstrated significant improvement in outcomes when receiving NMP compared to treatment as usual (TAU) in all RCTs. An associated cost analysis showed NMP to be more expensive than TAU (regression coefficient p = 0.0000), however experimental groups generated increased QALYs compared to TAU. Conclusion Limited evidence with overall unclear risk of bias exists evaluating clinical and cost-effectiveness of NMP across all professions and clinical settings. GRADE assessment revealed moderate quality evidence. Evidence suggests that NMP is safe and can provide beneficial clinical outcomes. Benefits to the health economy remain unclear, with the cost-effectiveness of NMP assessed by a single pilot RCT of low risk of bias. Adequately powered low risk of bias RCTs evaluating clinical and cost effectiveness are required to evaluate NMP across clinical specialities, professions and settings. Registration PROSPERO (CRD42015017212). PMID:29509763

  17. Behavioral Responses to Epidemics in an Online Experiment: Using Virtual Diseases to Study Human Behavior

    PubMed Central

    Chen, Frederick; Griffith, Amanda; Cottrell, Allin; Wong, Yue-Ling

    2013-01-01

    We report the results of a study we conducted using a simple multiplayer online game that simulates the spread of an infectious disease through a population composed of the players. We use our virtual epidemics game to examine how people respond to epidemics. The analysis shows that people's behavior is responsive to the cost of self-protection, the reported prevalence of disease, and their experiences earlier in the epidemic. Specifically, decreasing the cost of self-protection increases the rate of safe behavior. Higher reported prevalence also raises the likelihood that individuals would engage in self-protection, where the magnitude of this effect depends on how much time has elapsed in the epidemic. Individuals' experiences in terms of how often an infection was acquired when they did not engage in self-protection are another factor that determines whether they will invest in preventive measures later on. All else being equal, individuals who were infected at a higher rate are more likely to engage in self-protective behavior compared to those with a lower rate of infection. Lastly, fixing everything else, people's willingness to engage in safe behavior waxes or wanes over time, depending on the severity of an epidemic: when prevalence is high, people are more likely to adopt self-protective measures as time goes by; when prevalence is low, a ‘self-protection fatigue’ effect sets in whereby individuals are less willing to engage in safe behavior over time. PMID:23326360

  18. Prevalence and Perceived Financial Costs of Marijuana versus Tobacco use among Urban Low-Income Pregnant Women.

    PubMed

    Beatty, Jessica R; Svikis, Dace S; Ondersma, Steven J

    2012-09-30

    To examine the relative prevalence of marijuana and tobacco use among low-income post-partum women, using self-report, urine, and hair testing data; and to further explore perceptions of the substances among postpartum women by evaluating perceived risk and monetary cost of prenatal marijuana versus tobacco use. Data from two studies were available for a total of 100 (Study 1) and 50 (Study 2) low-income, primarily African-American post-partum women. Study 1 participants completed brief self-report measures of substance use as well as urine and hair samples; study 2 participants completed a brief opinion survey regarding the risks and monetary costs of prenatal marijuana use. In Study 1, the self-reported prevalence of any tobacco or marijuana use in the past three months was 17% and 11%, respectively. However, objectively-defined marijuana use was more prevalent than self-reported tobacco use: 14% tested positive for marijuana by urinalysis, and 28% by hair analysis. Study 2 participants were more likely to believe that there is a safe level of marijuana use during pregnancy, and nearly half believed that using marijuana during pregnancy was less expensive than smoking cigarettes. Marijuana use may be as or more prevalent than tobacco use among low-income, African-American pregnant women. These findings may in part be attributable to perceptions of roughly equivalent cost and the lack of a clear public health message regarding prenatal marijuana use, combined with growing pro-marijuana advocacy. A broader public health response to address prenatal marijuana use, along with other substances of abuse, is needed.

  19. Efforts of the occupant to change physical quality of residential unit through the change of building material at low cost flats in Jakarta

    NASA Astrophysics Data System (ADS)

    Nurdiani, N.

    2018-03-01

    Low cost flats in Jakarta – Indonesia is provided by the government for low-income people in urban areas, in line with the program to redevelop or renew slum areas. Low cost flat is built with the minimum standard of building materials. The purpose of this study is to know efforts of the occupants to change of building materials at residential unit of low cost flats. The research was conducted by descriptive method at four of low cost housing in Jakarta: Rusuna Bendungan Hilir 1, Rusuna Tambora IIIA, Rusuna Bidara Cina, and Rusuna Sukapura. The results showed that physical changes which happened in low cost flats are aesthetic (residence paint color change), or improvement of physical quality of residential unit (change of building material), become dominant aspects done by residents in four rusuna.

  20. Radionuclide Migration through Sediment and Concrete: 16 Years of Investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Golovich, Elizabeth C.; Mattigod, Shas V.; Snyder, Michelle MV

    The Waste Management Project provides safe, compliant, and cost-effective waste management services for the Hanford Site and the U.S. Department of Energy (DOE) complex. Part of these services includes safe disposal of low-level waste and mixed low-level waste at the Hanford Low-Level Waste Burial Grounds in accordance with the requirements of DOE Order 435.1, Radioactive Waste Management. To partially satisfy these requirements, performance assessment analyses were completed and approved. DOE Order 435.1 also requires continuing data collection to increase confidence in the critical assumptions used in these analyses to characterize the operational features of the disposal facility that are reliedmore » on to satisfy the performance objectives identified in the order. Cement-based solidification and stabilization is considered for hazardous waste disposal because it is easily done and cost-efficient. One critical assumption is that concrete will be used as a waste form or container material at the Hanford Site to control and minimize the release of radionuclide constituents in waste into the surrounding environment. Concrete encasement would contain and isolate the waste packages from the hydrologic environment and act as an intrusion barrier. Any failure of concrete encasement may result in water intrusion and consequent mobilization of radionuclides from the waste packages. The radionuclides iodine-129, selenium-75, technetium-99, and uranium-238 have been identified as long-term dose contributors (Mann et al. 2001; Wood et al. 1995). Because of their anionic nature in aqueous solutions, these constituents of potential concern may be released from the encased concrete by mass flow and/or diffusion and migrate into the surrounding subsurface environment (Serne et al. 1989; 1992; 1993a, b; 1995). Therefore, it is necessary to assess the performance of the concrete encasement structure and the ability of the surrounding soil to retard radionuclide migration. Each of the test methods performed throughout the lifetime of the project has focused on different aspects of the concrete waste form weathering process. Diffusion of different analytes [technetium-99 (Tc-99), iodine-125 (I-125), stable iodine (I), uranium (U), and rhenium (Re)] has been quantified from experiments under both saturated and unsaturated conditions. The water-saturated conditions provide a conservative estimate of the concrete’s performance in situ, and the unsaturated conditions provide a more accurate estimate of the diffusion of contaminants from the concrete.« less

  1. Experimental iron-inactivated Pasteurella multocida A: 1 vaccine adjuvanted with bacterial DNA is safe and protects chickens from fowl cholera.

    PubMed

    Herath, Chitra; Kumar, Pankaj; Singh, Mithilesh; Kumar, Devender; Ramakrishnan, Saravanan; Goswami, Tapas Kumar; Singh, Ajit; Ram, G C

    2010-03-08

    Fowl cholera is a serious problem in large and small scale poultry production. The present study describes the development and testing of an inactivated whole-cell, low-cost, safe, and effective vaccine for fowl cholera based on a previous work (Vaccine 23:5590-5598). Pasteurella multocida A: 1 grown in the presence of low FeCl(3) concentrations, inactivated with higher concentrations of FeCl(3), and adjuvanted with bacterial DNA from P. multocida B: 2 containing immunostimulatory CpG motifs protect chickens with a lethal P. multocida A: 1 challenge. Chickens were immunized with two whole-cell inactivated vaccine doses at 4 weeks apart and challenged 4 weeks after booster immunization. Experimental vaccines were pure, easy injectable, and caused very little distress in chickens due to their aqueous consistency. Vaccines and bacterial DNA (bDNA) posed no safety problems when chickens were injected subcutaneously (s.c.) with a single, double, and overdose of these preparations. Immunized chickens produced systemic IgY antibodies (Ab) responses and vaccine adjuvanted with bDNA protected 100% chickens from lethal intrapertoneal (i.p.) P. multocida A: 1 challenge. This work suggests that use of bDNA as an adjuvant can improve the cost-effectiveness of inactivated veterinary vaccines for their use in developing countries. Our future studies will focus on safety and potency evaluation of experimental and current vaccines using bDNA as an adjuvant. Copyright 2010 Elsevier Ltd. All rights reserved.

  2. Fabrication of low cost soft tissue prostheses with the desktop 3D printer

    NASA Astrophysics Data System (ADS)

    He, Yong; Xue, Guang-Huai; Fu, Jian-Zhong

    2014-11-01

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.

  3. Fabrication of low cost soft tissue prostheses with the desktop 3D printer

    PubMed Central

    He, Yong; Xue, Guang-huai; Fu, Jian-zhong

    2014-01-01

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods. PMID:25427880

  4. Fabrication of low cost soft tissue prostheses with the desktop 3D printer.

    PubMed

    He, Yong; Xue, Guang-huai; Fu, Jian-zhong

    2014-11-27

    Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.

  5. Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?

    PubMed Central

    Chouler, Jon; Di Lorenzo, Mirella

    2015-01-01

    The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries. PMID:26193327

  6. Water Quality Monitoring in Developing Countries; Can Microbial Fuel Cells be the Answer?

    PubMed

    Chouler, Jon; Di Lorenzo, Mirella

    2015-07-16

    The provision of safe water and adequate sanitation in developing countries is a must. A range of chemical and biological methods are currently used to ensure the safety of water for consumption. These methods however suffer from high costs, complexity of use and inability to function onsite and in real time. The microbial fuel cell (MFC) technology has great potential for the rapid and simple testing of the quality of water sources. MFCs have the advantages of high simplicity and possibility for onsite and real time monitoring. Depending on the choice of manufacturing materials, this technology can also be highly cost effective. This review covers the state-of-the-art research on MFC sensors for water quality monitoring, and explores enabling factors for their use in developing countries.

  7. Low-cost, light-switched, forward-osmosis desalination system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, John C.

    The looming water crisis is the second largest issue facing humanity after energy. In order to meet the increasing demand for clean water, new efficient and low-cost methods of water purification must be developed. A promising method for dry regions with sea borders is the desalination of seawater. While there remain many disadvantages to current desalination techniques, such as environmental pollution and high cost, there is a strong opportunity for new technology development in this area. In this Phase I program, the development of a light-switchable, low-cost desalination system was explored. The system requires photoselective switching of water solubility. Ninemore » new light-switchable spiropyran-based small molecule and polymeric materials were synthesized, and methods to evaluate their desalination potential were developed and utilized. Severable promising spiropyran analogues proved to be photoswitchable, but so far sufficient photoswitchablity of solubility for a commercial desalination system was not achieved. More development is required.« less

  8. Production of ELZM mirrors: performance coupled with attractive schedule, cost, and risk factors

    NASA Astrophysics Data System (ADS)

    Leys, Antoine; Hull, Tony; Westerhoff, Thomas

    2016-08-01

    Extreme light weighted ZERODUR Mirrors (ELZM) have been developed to exploit the superb thermal characteristics of ZERODUR. Coupled with up to date mechanical and optical fabrication methods this becomes an attractive technical approach. However the process of making mirror substrates has demonstrated to be unusually rapid and especially cost-effective. ELZM is aimed at the knee of the cost as a function of light weighting curve. ELZM mirrors are available at 88% light weighted. Together with their low risk, low cost production methods, this is presented as a strong option for NASA Explorer and Probe class missions.

  9. Low-cost periodontal therapy.

    PubMed

    Slots, Jørgen

    2012-10-01

    Periodontitis is a complex infectious disease that affects low-income individuals disproportionately. Periodontitis is associated with specific bacterial species and herpesviruses, and successful prevention and treatment of the disease is contingent upon effective control of these pathogens. This article presents an efficacious, highly safe, minimally invasive, practical and low-cost periodontal therapy that involves professional and patient-administered mechanical therapy and antimicrobial agents. The major components are scaling for calculus removal, periodontal pocket irrigation with potent antiseptics, and treatment with systemic antibiotics for advanced disease. Povidone-iodine and sodium hypochlorite have all the characteristics for becoming the first-choice antiseptics in the management of periodontal diseases. Both agents show excellent antibacterial and antiviral properties, are readily available throughout the world, have been safely used in periodontal therapy for decades, offer significant benefits for individuals with very limited financial resources, and are well accepted by most dental professionals and patients. Four per cent chlorhexidine applied with a toothbrush to the most posterior part to the tongue dorsum can markedly reduce or eliminate halitosis in most individuals. Systemic antibiotics are used to treat periodontopathic bacteria that are not readily reached by topical therapy, such as pathogens within gingival tissue, within furcation defects, at the base of periodontal pockets, and on the tongue, tonsils and buccal mucosae. Valuable antibiotic therapies are amoxicillin-metronidazole (250 mg of amoxicillin and 250 mg of metronidazole, three times daily for 8 days) for young and middle-aged patients, and ciprofloxacin-metronidazole (500 mg of each, twice daily for 8 days) for elderly patients and for patients in developing countries who frequently harbor enteric rods subgingivally. Scaling to remove dental calculus and the prudent use of inexpensive antimicrobial agents can significantly retard or arrest progressive periodontitis in the great majority of patients. © 2012 John Wiley & Sons A/S.

  10. Validation of a low cost computer-based method for quantification of immunohistochemistry-stained sections.

    PubMed

    Montgomery, Jill D; Hensler, Heather R; Jacobson, Lisa P; Jenkins, Frank J

    2008-07-01

    The aim of the present study was to determine if the Alpha DigiDoc RT system would be an effective method of quantifying immunohistochemical staining as compared with a manual counting method, which is considered the gold standard. Two readers were used to count 31 samples by both methods. The results obtained using the Bland-Altman for concordance deemed no statistical difference between the 2 methods. Thus, the Alpha DigiDoc RT system is an effective, low cost method to quantify immunohistochemical data.

  11. SUDI prevention: a review of Maori safe sleep innovations for infants.

    PubMed

    Abel, Sally; Tipene-Leach, David

    2013-08-02

    Recent research and policy around sudden unexpected death in infancy (SUDI) have emphasised the place of safe sleeping practices within SUDI prevention strategies. Maori SUDI prevention workers have focussed on innovations around the safe sleep environment for some time now, as they have grappled with difficult to change and disproportionately high Maori SUDI rates. The wahakura (a flax bassinet modelled on a traditional Maori infant sleeping item) was developed in 2006 aiming to mitigate some of the risks of bedsharing with vulnerable infants, in particular infants exposed to maternal smoking in pregnancy. Early wahakura projects in Gisborne and Hawke's Bay showed high acceptability, effectiveness as an infant health promotion vehicle but difficulty maintaining a low/no cost supply for vulnerable families. The Hawke's Bay project revealed two pathways forward: the need for robust research to ensure the safety of the wahakura and the exploration of financially viable and more readily available alternatives. Work on both pathways is currently in progress around the country, signalling New Zealand's ongoing contribution to SUDI prevention and its potential contribution to knowledge and practices applicable to indigenous and other marginalised communities worldwide.

  12. Human Spaceflight Safety for the Next Generation on Orbital Space Systems

    NASA Technical Reports Server (NTRS)

    Mango, Edward J.

    2011-01-01

    The National Aeronautics and Space Administration (NASA) Commercial Crew Program (CCP) has been chartered to facilitate the development of a United States (U.S.) commercial crew space transportation capability with the goal of achieving safe, reliable, and cost effective access to and from low Earth orbit (LEO) and the International Space Station (ISS) as soon as possible. Once the capability is matured and is available to the Government and other customers, NASA expects to purchase commercial services to meet its ISS crew rotation and emergency return objectives. The primary role of the CCP is to enable and ensure safe human spaceflight and processes for the next generation of earth orbital space systems. The architecture of the Program delineates the process for investment performance in safe orbital systems, Crew Transportation System (CTS) certification, and CTS Flight Readiness. A series of six technical documents build up the architecture to address the top-level CTS requirements and standards. They include Design Reference Missions, with the near term focus on ISS crew services, Certification and Service Requirements, Technical Management Processes, and Technical and Operations Standards Evaluation Processes.

  13. Novel method to reduce fishy aftertaste in wine and seafood pairing using alcohol-treated yeast cells.

    PubMed

    Tsuji, Toshikazu; Kanai, Keiko; Yokoyama, Aki; Tamura, Takayuki; Hanamure, Kenichi; Sasaki, Kanako; Takata, Ryoji; Yoshida, Satoshi

    2012-06-20

    "Fishy aftertaste" is sometimes perceived in wine consumed with seafood. Iron in wine has been reported to be a key compound that produces fishy aftertaste. However, cost-effective methods to remove iron from wine have not been developed. Here, we describe a cost-effective and safe iron adsorbent consisting of alcohol-treated yeast (ATY) cells based on the observation that nonviable cells adsorbed iron after completion of fermentation. Treatment of cells with more than 40% (v/v) ethanol killed them without compromising their ability to adsorb iron. Drying the ATY cells did not reduce iron adsorption. Use of ATY cells together with phytic acid had a synergistic effect on iron removal. We term this means of removing iron the "ATY-PA" method. Sensory analysis indicated that fishy aftertaste in wine-seafood pairings was not perceived if the wine had been pretreated with both ATY cells and phytic acid.

  14. Current trends in treatment of obesity in Karachi and possibilities of cost minimization.

    PubMed

    Hussain, Mirza Izhar; Naqvi, Baqir Shyum

    2015-03-01

    Our study finds out drug usage trends in over weight and obese patients without any compelling indications in Karachi, looks for deviations of current practices from evidence based antihypertensive therapeutic guidelines and identifies not only cost minimization opportunities but also communication strategies to improve patients' awareness and compliance to achieve therapeutic goal. In present study two sets were used. Randomized stratified independent surveys were conducted in hospital doctors and family physicians (general practitioners), using pretested questionnaires. Sample size was 100. Statistical analysis was conducted on Statistical Package for Social Science (SPSS). Opportunities of cost minimization were also analyzed. One the basis of doctors' feedback, preference is given to non-pharmacologic management of obesity. Mass media campaign and media usage were recommended to increase patients awareness and patients' education along with strengthening family support systems was recommended for better compliance of the patients to doctor's advice. Local therapeutic guidelines for weight reduction were not found. Feedbacks showed that global therapeutic guidelines were followed by the doctors practicing in the community and hospitals in Karachi. However, high price branded drugs were used instead of low priced generic therapeutic equivalents. Patient's education is required for better awareness and improving patients' compliance. The doctors found preferring brand leaders instead of low cost options. This trend increases cost of therapy by 0.59 to 4.17 times. Therefore, there are great opportunities for cost minimization by using evidence-based clinically effective and safe medicines.

  15. Organizing for low cost space operations - Status and plans

    NASA Technical Reports Server (NTRS)

    Lee, C.

    1976-01-01

    Design features of the Space Transportation System (vehicle reuse, low cost expendable components, simple payload interfaces, standard support systems) must be matched by economical operational methods to achieve low operating and payload costs. Users will be responsible for their own payloads and will be charged according to the services they require. Efficient use of manpower, simple documentation, simplified test, checkout, and flight planning are firm goals, together with flexibility for quick response to varying user needs. Status of the Shuttle hardware, plans for establishing low cost procedures, and the policy for user charges are discussed.

  16. [Hybrid repair of postoperative ventral hernia].

    PubMed

    Gogiya, B Sh; Alyautdinov, R R; Karmazanovsky, G G; Chekmareva, I A; Kopyltsov, A A

    2018-01-01

    To develop new technique of abdominal wall repair for postoperative ventral hernia without disadvantages which are intrinsic for open and laparoscopic surgery. Combined open and laparoscopic hernia repair was used in 18 patients with postoperative ventral hernia. Open stage provided safe dissection of abdominal adhesions and defect closure by autoplasty, laparoscopic procedure consisted of prosthesis deployment without separation of abdominal wall layers. Two types of composite endoprostheses with anti-adhesive coating were used for abdominal wall repair. There were no cases of recurrence or infectious complications in long-term period (from 3 to 106 months). Hybrid repair of postoperative ventral hernia is safe and effective procedure. Further studies are necessary to assess cost-effectiveness ratio of this method in view of expensive composite endoprostheses and laparoscopic supplies.

  17. Low dose DTIC is effective and safe in pretreated patients with well differentiated neuroendocrine tumors.

    PubMed

    Mueller, Daniela; Krug, Sebastian; Majumder, Moushumee; Rinke, Anja; Gress, Thomas Matthias

    2016-08-18

    Streptozocin (STZ) based chemotherapy is recommended for patients with metastatic pancreatic neuroendocrine tumors (pNET). Temozolomide as mono- or combination therapy has been suggested to be a promising alternative. However, the treatment is costly and not approved for the treatment of pNETs. Dacarbazine (DTIC) shares the active metabolite with temozolomide and is broadly available at a low cost. The aim of this study was a retrospective evaluation of the efficacy and tolerability of a lower dose DTIC-regimen in patients with progressive advanced NETs. We retrospectively analyzed 75 patients with NETs predominantly of pancreatic origin treated at our center between 1998 and 2013. 650 mg/m(2) of DTIC were administered intravenously over 60 min every 4 weeks. Morphological response was assessed according to RECIST1.1 criteria. The median progression free survival (PFS) was calculated using Kaplan-Meier and Cox regression methods, respectively. Univariate analyses of possible prognostic markers were performed. The objective response rate (ORR) was 27 % for the entire cohort and 32 % in 50 pNET patients, respectively. Stable disease (SD) was documented in 29 patients (39 %). Median PFS (mPFS) in patients receiving DTIC was 7 months (3.9-10; 95 % confidence interval). Radiological and biochemical response were the only significant prognostic markers for longer PFS in univariate analysis. Treatment was well tolerated. Nausea was the most common side effect (31 %), only one case (1.3 %) of grade 3 toxicity (vomiting) occurred. Low dose DTIC chemotherapy is an effective and well-tolerated treatment option in patients with progressive well differentiated neuroendocrine neoplasms, especially of pancreatic origin.

  18. ARE660 Wind Generator: Low Wind Speed Technology for Small Turbine Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robert W. Preus; DOE Project Officer - Keith Bennett

    2008-04-23

    This project is for the design of a wind turbine that can generate most or all of the net energy required for homes and small businesses in moderately windy areas. The purpose is to expand the current market for residential wind generators by providing cost effective power in a lower wind regime than current technology has made available, as well as reduce noise and improve reliability and safety. Robert W. Preus’ experience designing and/or maintaining residential wind generators of many configurations helped identify the need for an improved experience of safety for the consumer. Current small wind products have unreliablemore » or no method of stopping the wind generator in fault or high wind conditions. Consumers and their neighbors do not want to hear their wind generators. In addition, with current technology, only sites with unusually high wind speeds provide payback times that are acceptable for the on-grid user. Abundant Renewable Energy’s (ARE) basic original concept for the ARE660 was a combination of a stall controlled variable speed small wind generator and automatic fail safe furling for shutdown. The stall control for a small wind generator is not novel, but has not been developed for a variable speed application with a permanent magnet alternator (PMA). The fail safe furling approach for shutdown has not been used to our knowledge.« less

  19. Safety and efficacy of Regadenoson in myocardial perfusion imaging (MPI) stress tests: A review

    NASA Astrophysics Data System (ADS)

    Ahmed, Ambereen

    2018-02-01

    Myocardial perfusion imaging (MPI) tests are often used to help diagnose coronary heart disease (CAD). The tests usually involve applying stress, such as hard physical exercise together with administration of vasodilators, to the patients. To date, many of these tests use non-selective A2A adenosine receptor agonists which, however, can be associated with highly undesirable and life-threatening side effects such as chest pain, dyspnea, severe bronchoconstriction and atrioventricular conduction anomalies. Regadenoson is a relatively new, highly selective A2A adenosine receptor agonist, suitable for use in MPI tests which exhibits far fewer adverse side effects and, unlike others testing agents, can be used without the necessity of excessive concomitant exercise. Also, the dose of regadenoson required is not dependent upon patient weight or renal impairment, and it can be rapidly administered by i.v. Injection. Regadenoson use in MPI testing thus has the potential as a simplified, relatively safe, time-saving and cost-effective method for helping diagnose CAD. The present study was designed to review several articles on the safety, efficacy, and suitability of regadenoson in MPI testing for CAD. Overall, the combined studies demonstrated that use of regadenoson in conjunction with low-level exercise in MPI is a highly efficient and relatively safe test for CAD, especially for more severe health-compromised patients.

  20. Leishmaniasis: focus on the design of nanoparticulate vaccine delivery systems.

    PubMed

    Doroud, Delaram; Rafati, Sima

    2012-01-01

    Although mass vaccination of the entire population of an endemic area would be the most cost-effective tool to diminish Leishmania burden, an effective vaccine is not yet commercially available. Practically, vaccines have failed to achieve the required level of protection, possibly owing to the lack of an appropriate adjuvant and/or delivery system. Therefore, there is still an imperative demand for an improved, safe and efficient delivery system to enhance the immunogenicity of available vaccine candidates. Nanoparticles are proficient in boosting the quality and magnitude of immune responses in a predictable fashion. Herein, we discuss how nanoparticulate vaccine delivery systems can be used to induce appropriate immune responses against leishmaniasis by controlling physicochemical properties of the vaccine. Stability, production reproducibility, low cost per dose and low risk-benefit ratios are desirable characteristics of an ideal vaccine formulation and solid lipid nanoparticles may serve as one of the most promising practical strategies to help to achieve such a leishmanial vaccine, at least in canine species in the developing world.

  1. In-Situ Characterization of Underwater Radioactive Sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpson, A.P.; Clapham, M.J.; Swinson, B.

    2008-07-01

    A fundamental requirement underpinning safe clean-up technologies for legacy spent nuclear fuel (SNF) ponds, pools and wet silos is the ability to characterize the radioactive waste form prior to retrieval. The corrosion products resulting from the long term underwater storage of spent nuclear fuel, reactor components and reprocessing debris present a major hazard to facility decontamination and decommissioning in terms of their radioactive content and physical / chemical reactivity. The ability to perform in-situ underwater non-destructive characterization of sludge and debris in a safe and cost-effective manner offers significant benefits over traditional destructive sampling methods. Several techniques are available formore » underwater measurements including (i) Gross gamma counting, (ii) Low-, Medium- and High- Resolution Gamma Spectroscopy, (iii) Passive neutron counting and (iv) Active Neutron Interrogation. The optimum technique depends on (i) the radioactive inventory (ii) mechanical access restrictions for deployment of the detection equipment, interrogation sources etc. (iii) the integrity of plant records and (iv) the extent to which Acceptable Knowledge which may be used for 'fingerprinting' the radioactive contents to a marker nuclide. Prior deployments of underwater SNF characterization equipment around the world have been reviewed with respect to recent developments in gamma and neutron detection technologies, digital electronics advancements, data transfer techniques, remote operation capabilities and improved field ruggedization. Modeling and experimental work has been performed to determine the capabilities, performance envelope and operational limitations of the future generation of non-destructive underwater sludge characterization techniques. Recommendations are given on the optimal design of systems and procedures to provide an acceptable level of confidence in the characterization of residual sludge content of legacy wet storage facilities such that retrieval and repackaging of SNF sludges may proceed safely and efficiently with support of the regulators and the public. (author)« less

  2. Biomedical microfluidic devices by using low-cost fabrication techniques: A review.

    PubMed

    Faustino, Vera; Catarino, Susana O; Lima, Rui; Minas, Graça

    2016-07-26

    One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made to develop low-cost alternatives for the fabrication of microstructures, avoiding the use of cleanroom facilities. Recently, low-cost techniques without cleanroom facilities that feature aspect ratios more than 20, for fabricating those SU-8 moulds have been gaining popularity among biomedical research community. In those techniques, Ultraviolet (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, replaces the more expensive and less available Mask Aligner that has been used in the last 15 years for SU-8 patterning. Alternatively, non-lithographic low-cost techniques, due to their ability for large-scale production, have increased the interest of the industrial and research community to develop simple, rapid and low-cost microfluidic structures. These alternative techniques include Print and Peel methods (PAP), laserjet, solid ink, cutting plotters or micromilling, that use equipment available in almost all laboratories and offices. An example is the xurography technique that uses a cutting plotter machine and adhesive vinyl films to generate the master moulds to fabricate microfluidic channels. In this review, we present a selection of the most recent lithographic and non-lithographic low-cost techniques to fabricate microfluidic structures, focused on the features and limitations of each technique. Only microfabrication methods that do not require the use of cleanrooms are considered. Additionally, potential applications of these microfluidic devices in biomedical engineering are presented with some illustrative examples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A Low-Cost Teaching Model of Inguinal Canal: A Useful Method to Teach Surgical Concepts in Hernia Repair

    ERIC Educational Resources Information Center

    Ansaloni, Luca; Catena, Fausto; Coccolini, Frederico; Ceresoli, Marco; Pinna, Antonio Daniele

    2014-01-01

    Objectives: Inguinal canal anatomy and hernia repair is difficult for medical students and surgical residents to comprehend. Methods: Using low-cost material, a 3-dimensional inexpensive model of the inguinal canal was created to allow students to learn anatomical details and landmarks and to perform their own simulated hernia repair. In order to…

  4. Vision and Control for UAVs: A Survey of General Methods and of Inexpensive Platforms for Infrastructure Inspection

    PubMed Central

    Máthé, Koppány; Buşoniu, Lucian

    2015-01-01

    Unmanned aerial vehicles (UAVs) have gained significant attention in recent years. Low-cost platforms using inexpensive sensor payloads have been shown to provide satisfactory flight and navigation capabilities. In this report, we survey vision and control methods that can be applied to low-cost UAVs, and we list some popular inexpensive platforms and application fields where they are useful. We also highlight the sensor suites used where this information is available. We overview, among others, feature detection and tracking, optical flow and visual servoing, low-level stabilization and high-level planning methods. We then list popular low-cost UAVs, selecting mainly quadrotors. We discuss applications, restricting our focus to the field of infrastructure inspection. Finally, as an example, we formulate two use-cases for railway inspection, a less explored application field, and illustrate the usage of the vision and control techniques reviewed by selecting appropriate ones to tackle these use-cases. To select vision methods, we run a thorough set of experimental evaluations. PMID:26121608

  5. Efficacy of a low-cost bubble CPAP system in treatment of respiratory distress in a neonatal ward in Malawi.

    PubMed

    Kawaza, Kondwani; Machen, Heather E; Brown, Jocelyn; Mwanza, Zondiwe; Iniguez, Suzanne; Gest, Al; O'Brian Smith, E; Oden, Maria; Richards-Kortum, Rebecca R; Molyneux, Elizabeth

    2016-09-01

    Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP) is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care. We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups. 87 neonates (62 bCPAP, 25 controls) were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62) compared with 44.0% (11/25) for controls. 65.5% (19/29) of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13) of controls. 64.6% (31/48) of neonates with respiratory distress syndrome (RDS) receiving bCPAP survived to discharge, compared to 23.5% (4/17) of controls. 61.5% (16/26) of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived. Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries.

  6. Efficacy of a low-cost bubble CPAP system in treatment of respiratory distress in a neonatal ward in Malawi.

    PubMed

    Kawaza, Kondwani; Machen, Heather E; Brown, Jocelyn; Mwanza, Zondiwe; Iniguez, Suzanne; Gest, Al; Smith, E O'Brian; Oden, Maria; Richards-Kortum, Rebecca R; Molyneux, Elizabeth

    2014-01-01

    Respiratory failure is a leading cause of neonatal mortality in the developing world. Bubble continuous positive airway pressure (bCPAP) is a safe, effective intervention for infants with respiratory distress and is widely used in developed countries. Because of its high cost, bCPAP is not widely utilized in low-resource settings. We evaluated the performance of a new bCPAP system to treat severe respiratory distress in a low resource setting, comparing it to nasal oxygen therapy, the current standard of care. We conducted a non-randomized convenience sample study to test the efficacy of a low-cost bCPAP system treating newborns with severe respiratory distress in the neonatal ward of Queen Elizabeth Central Hospital, in Blantyre, Malawi. Neonates weighing >1,000 g and presenting with severe respiratory distress who fulfilled inclusion criteria received nasal bCPAP if a device was available; if not, they received standard care. Clinical assessments were made during treatment and outcomes compared for the two groups. 87 neonates (62 bCPAP, 25 controls) were recruited. Survival rate for neonates receiving bCPAP was 71.0% (44/62) compared with 44.0% (11/25) for controls. 65.5% (19/29) of very low birth weight neonates receiving bCPAP survived to discharge compared to 15.4% (1/13) of controls. 64.6% (31/48) of neonates with respiratory distress syndrome (RDS) receiving bCPAP survived to discharge, compared to 23.5% (4/17) of controls. 61.5% (16/26) of neonates with sepsis receiving bCPAP survived to discharge, while none of the seven neonates with sepsis in the control group survived. Use of a low-cost bCPAP system to treat neonatal respiratory distress resulted in 27% absolute improvement in survival. The beneficial effect was greater for neonates with very low birth weight, RDS, or sepsis. Implementing appropriate bCPAP devices could reduce neonatal mortality in developing countries.

  7. In situ carbonation of peridotite for CO2 storage

    PubMed Central

    Kelemen, Peter B.; Matter, Jürg

    2008-01-01

    The rate of natural carbonation of tectonically exposed mantle peridotite during weathering and low-temperature alteration can be enhanced to develop a significant sink for atmospheric CO2. Natural carbonation of peridotite in the Samail ophiolite, an uplifted slice of oceanic crust and upper mantle in the Sultanate of Oman, is surprisingly rapid. Carbonate veins in mantle peridotite in Oman have an average 14C age of ≈26,000 years, and are not 30–95 million years old as previously believed. These data and reconnaissance mapping show that ≈104 to 105 tons per year of atmospheric CO2 are converted to solid carbonate minerals via peridotite weathering in Oman. Peridotite carbonation can be accelerated via drilling, hydraulic fracture, input of purified CO2 at elevated pressure, and, in particular, increased temperature at depth. After an initial heating step, CO2 pumped at 25 or 30 °C can be heated by exothermic carbonation reactions that sustain high temperature and rapid reaction rates at depth with little expenditure of energy. In situ carbonation of peridotite could consume >1 billion tons of CO2 per year in Oman alone, affording a low-cost, safe, and permanent method to capture and store atmospheric CO2.

  8. Air-to-Water Heat Pumps With Radiant Delivery in Low-Load Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Backman, C.; German, A.; Dakin, B.

    2013-12-01

    Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 tomore » test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).« less

  9. Designing informed game-based rehabilitation tasks leveraging advances in virtual reality.

    PubMed

    Lange, Belinda; Koenig, Sebastian; Chang, Chien-Yen; McConnell, Eric; Suma, Evan; Bolas, Mark; Rizzo, Albert

    2012-01-01

    This paper details a brief history and rationale for the use of virtual reality (VR) technology for clinical research and intervention, and then focuses on game-based VR applications in the area of rehabilitation. An analysis of the match between rehabilitation task requirements and the assets available with VR technology is presented. Low-cost camera-based systems capable of tracking user behavior at sufficient levels for game-based virtual rehabilitation activities are currently available for in-home use. Authoring software is now being developed that aims to provide clinicians with a usable toolkit for leveraging this technology. This will facilitate informed professional input on software design, development and application to ensure safe and effective use in the rehabilitation context. The field of rehabilitation generally stands to benefit from the continual advances in VR technology, concomitant system cost reductions and an expanding clinical research literature and knowledge base. Home-based activity within VR systems that are low-cost, easy to deploy and maintain, and meet the requirements for "good" interactive rehabilitation tasks could radically improve users' access to care, adherence to prescribed training and subsequently enhance functional activity in everyday life in clinical populations.

  10. Development of a Closed-Loop Strap Down Attitude System for an Ultrahigh Altitude Flight Experiment

    NASA Technical Reports Server (NTRS)

    Whitmore, Stephen A.; Fife, Mike; Brashear, Logan

    1997-01-01

    A low-cost attitude system has been developed for an ultrahigh altitude flight experiment. The experiment uses a remotely piloted sailplane, with the wings modified for flight at altitudes greater than 100,000 ft. Mission requirements deem it necessary to measure the aircraft pitch and bank angles with accuracy better than 1.0 deg and heading with accuracy better than 5.0 deg. Vehicle cost restrictions and gross weight limits make installing a commercial inertial navigation system unfeasible. Instead, a low-cost attitude system was developed using strap down components. Monte Carlo analyses verified that two vector measurements, magnetic field and velocity, are required to completely stabilize the error equations. In the estimating algorithm, body-axis observations of the airspeed vector and the magnetic field are compared against the inertial velocity vector and a magnetic-field reference model. Residuals are fed back to stabilize integration of rate gyros. The effectiveness of the estimating algorithm was demonstrated using data from the NASA Dryden Flight Research Center Systems Research Aircraft (SRA) flight tests. The algorithm was applied with good results to a maximum 10' pitch and bank angles. Effects of wind shears were evaluated and, for most cases, can be safely ignored.

  11. Unsynchronized scanning with a low-cost laser range finder for real-time range imaging

    NASA Astrophysics Data System (ADS)

    Hatipoglu, Isa; Nakhmani, Arie

    2017-06-01

    Range imaging plays an essential role in many fields: 3D modeling, robotics, heritage, agriculture, forestry, reverse engineering. One of the most popular range-measuring technologies is laser scanner due to its several advantages: long range, high precision, real-time measurement capabilities, and no dependence on lighting conditions. However, laser scanners are very costly. Their high cost prevents widespread use in applications. Due to the latest developments in technology, now, low-cost, reliable, faster, and light-weight 1D laser range finders (LRFs) are available. A low-cost 1D LRF with a scanning mechanism, providing the ability of laser beam steering for additional dimensions, enables to capture a depth map. In this work, we present an unsynchronized scanning with a low-cost LRF to decrease scanning period and reduce vibrations caused by stop-scan in synchronized scanning. Moreover, we developed an algorithm for alignment of unsynchronized raw data and proposed range image post-processing framework. The proposed technique enables to have a range imaging system for a fraction of the price of its counterparts. The results prove that the proposed method can fulfill the need for a low-cost laser scanning for range imaging for static environments because the most significant limitation of the method is the scanning period which is about 2 minutes for 55,000 range points (resolution of 250x220 image). In contrast, scanning the same image takes around 4 minutes in synchronized scanning. Once faster, longer range, and narrow beam LRFs are available, the methods proposed in this work can produce better results.

  12. Smart aircraft fastener evaluation (SAFE) system: a condition-based corrosion detection system for aging aircraft

    NASA Astrophysics Data System (ADS)

    Schoess, Jeffrey N.; Seifert, Greg; Paul, Clare A.

    1996-05-01

    The smart aircraft fastener evaluation (SAFE) system is an advanced structural health monitoring effort to detect and characterize corrosion in hidden and inaccessible locations of aircraft structures. Hidden corrosion is the number one logistics problem for the U.S. Air Force, with an estimated maintenance cost of $700M per year in 1990 dollars. The SAFE system incorporates a solid-state electrochemical microsensor and smart sensor electronics in the body of a Hi-Lok aircraft fastener to process and autonomously report corrosion status to aircraft maintenance personnel. The long-term payoff for using SAFE technology will be in predictive maintenance for aging aircraft and rotorcraft systems, fugitive emissions applications such as control valves, chemical pipeline vessels, and industrial boilers. Predictive maintenance capability, service, and repair will replace the current practice of scheduled maintenance to substantially reduce operational costs. A summary of the SAFE concept, laboratory test results, and future field test plans is presented.

  13. Strengthening Cost-Effectiveness Analysis for Public Health Policy.

    PubMed

    Russell, Louise B; Sinha, Anushua

    2016-05-01

    Although the U.S. spends more on medical care than any country in the world, Americans live shorter lives than the citizens of other high-income countries. Many important opportunities to improve this record lie outside the health sector and involve improving the conditions in which Americans live and work: safe design and maintenance of roads, bridges, train tracks, and airports; control of environmental pollutants; occupational safety; healthy buildings; a safe and healthy food supply; safe manufacture of consumer products; a healthy social environment; and others. Faced with the overwhelming array of possibilities, U.S. decision makers need help identifying those that can contribute the most to health. Cost-effectiveness analysis is designed to serve that purpose, but has mainly been used to assess interventions within the health sector. This paper briefly reviews the objective of cost-effectiveness analysis and its methodologic evolution and discusses the issues that arise when it is used to evaluate interventions that fall outside the health sector under three headings: structuring the analysis, quantifying/measuring benefits and costs, and valuing benefits and costs. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  14. Ubiquitous Wireless Smart Sensing and Control

    NASA Technical Reports Server (NTRS)

    Wagner, Raymond

    2013-01-01

    Need new technologies to reliably and safely have humans interact within sensored environments (integrated user interfaces, physical and cognitive augmentation, training, and human-systems integration tools). Areas of focus include: radio frequency identification (RFID), motion tracking, wireless communication, wearable computing, adaptive training and decision support systems, and tele-operations. The challenge is developing effective, low cost/mass/volume/power integrated monitoring systems to assess and control system, environmental, and operator health; and accurately determining and controlling the physical, chemical, and biological environments of the areas and associated environmental control systems.

  15. Ubiquitous Wireless Smart Sensing and Control. Pumps and Pipes JSC: Uniquely Houston

    NASA Technical Reports Server (NTRS)

    Wagner, Raymond

    2013-01-01

    Need new technologies to reliably and safely have humans interact within sensored environments (integrated user interfaces, physical and cognitive augmentation, training, and human-systems integration tools).Areas of focus include: radio frequency identification (RFID), motion tracking, wireless communication, wearable computing, adaptive training and decision support systems, and tele-operations. The challenge is developing effective, low cost/mass/volume/power integrated monitoring systems to assess and control system, environmental, and operator health; and accurately determining and controlling the physical, chemical, and biological environments of the areas and associated environmental control systems.

  16. Crew emergency return vehicle - Electrical power system design study

    NASA Technical Reports Server (NTRS)

    Darcy, E. C.; Barrera, T. P.

    1989-01-01

    A crew emergency return vehicle (CERV) is proposed to perform the lifeboat function for the manned Space Station Freedom. This escape module will be permanently docked to Freedom and, on demand, will be capable of safely returning the crew to earth. The unique requirements that the CERV imposes on its power source are presented, power source options are examined, and a baseline system is selected. It consists of an active Li-BCX DD-cell modular battery system and was chosen for the maturity of its man-rated design and its low development costs.

  17. On-line adaptive battery impedance parameter and state estimation considering physical principles in reduced order equivalent circuit battery models. Part 1. Requirements, critical review of methods and modeling

    NASA Astrophysics Data System (ADS)

    Fleischer, Christian; Waag, Wladislaw; Heyn, Hans-Martin; Sauer, Dirk Uwe

    2014-08-01

    Lithium-ion battery systems employed in high power demanding systems such as electric vehicles require a sophisticated monitoring system to ensure safe and reliable operation. Three major states of the battery are of special interest and need to be constantly monitored, these include: battery state of charge (SoC), battery state of health (capcity fade determination, SoH), and state of function (power fade determination, SoF). In a series of two papers, we propose a system of algorithms based on a weighted recursive least quadratic squares parameter estimator, that is able to determine the battery impedance and diffusion parameters for accurate state estimation. The functionality was proven on different battery chemistries with different aging conditions. The first paper investigates the general requirements on BMS for HEV/EV applications. In parallel, the commonly used methods for battery monitoring are reviewed to elaborate their strength and weaknesses in terms of the identified requirements for on-line applications. Special emphasis will be placed on real-time capability and memory optimized code for cost-sensitive industrial or automotive applications in which low-cost microcontrollers must be used. Therefore, a battery model is presented which includes the influence of the Butler-Volmer kinetics on the charge-transfer process. Lastly, the mass transport process inside the battery is modeled in a novel state-space representation.

  18. Internet-Delivered Psychological Treatments for Mood and Anxiety Disorders: A Systematic Review of Their Efficacy, Safety, and Cost-Effectiveness

    PubMed Central

    Arnberg, Filip K.; Linton, Steven J.; Hultcrantz, Monica; Heintz, Emelie; Jonsson, Ulf

    2014-01-01

    Background Greater access to evidence-based psychological treatments is needed. This review aimed to evaluate whether internet-delivered psychological treatments for mood and anxiety disorders are efficacious, noninferior to established treatments, safe, and cost-effective for children, adolescents and adults. Methods We searched the literature for studies published until March 2013. Randomized controlled trials (RCTs) were considered for the assessment of short-term efficacy and safety and were pooled in meta-analyses. Other designs were also considered for long-term effect and cost-effectiveness. Comparisons against established treatments were evaluated for noninferiority. Two reviewers independently assessed the relevant studies for risk of bias. The quality of the evidence was graded using an international grading system. Results A total of 52 relevant RCTs were identified whereof 12 were excluded due to high risk of bias. Five cost-effectiveness studies were identified and three were excluded due to high risk of bias. The included trials mainly evaluated internet-delivered cognitive behavioral therapy (I-CBT) against a waiting list in adult volunteers and 88% were conducted in Sweden or Australia. One trial involved children. For adults, the quality of evidence was graded as moderate for the short-term efficacy of I-CBT vs. waiting list for mild/moderate depression (d = 0.83; 95% CI 0.59, 1.07) and social phobia (d = 0.85; 95% CI 0.66, 1.05), and moderate for no efficacy of internet-delivered attention bias modification vs. sham treatment for social phobia (d = −0.04; 95% CI −0.24, 0.35). The quality of evidence was graded as low/very low for other disorders, interventions, children/adolescents, noninferiority, adverse events, and cost-effectiveness. Conclusions I-CBT is a viable treatment option for adults with depression and some anxiety disorders who request this treatment modality. Important questions remain before broad implementation can be supported. Future research would benefit from prioritizing adapting treatments to children/adolescents and using noninferiority designs with established forms of treatment. PMID:24844847

  19. Behavioral Determinants of Switching to Arsenic-Safe Water Wells.

    PubMed

    George, Christine Marie; Inauen, Jennifer; Perin, Jamie; Tighe, Jennifer; Hasan, Khaled; Zheng, Yan

    2017-02-01

    More than 100 million people globally are estimated to be exposed to arsenic in drinking water that exceeds the World Health Organization guideline of 10 µg/L. In an effort to develop and test a low-cost sustainable approach for water arsenic testing in Bangladesh, we conducted a randomized controlled trial which found arsenic educational interventions when combined with fee-based water arsenic testing programs led to nearly all households buying an arsenic test for their drinking water sources (93%) compared with only 53% when fee-based arsenic testing alone was offered. The aim of the present study was to build on the findings of this trial by investigating prospectively the psychological factors that were most strongly associated with switching to arsenic-safe wells in response to these interventions. Our theoretical framework was the RANAS (risk, attitude, norm, ability, and self-regulation) model of behavior change. In the multivariate logistic regression model of 285 baseline unsafe well users, switching to an arsenic-safe water source was significantly associated with increased instrumental attitude (odds ratio [OR] = 9.12; 95% confidence interval [CI] = [1.85, 45.00]), descriptive norm (OR = 34.02; 95% CI = [6.11, 189.45]), coping planning (OR = 11.59; 95% CI = [3.82, 35.19]), and commitment (OR = 10.78; 95% CI = [2.33, 49.99]). In addition, each additional minute from the nearest arsenic-safe drinking water source reduced the odds of switching to an arsenic-safe well by more than 10% (OR = 0.89; 95% CI = [0.87, 0.92]). Future arsenic mitigation programs should target these behavioral determinants of switching to arsenic-safe water sources.

  20. System identification of a small low-cost unmanned aerial vehicle using flight data from low-cost sensors

    NASA Astrophysics Data System (ADS)

    Hoffer, Nathan Von

    Remote sensing has traditionally been done with satellites and manned aircraft. While. these methods can yield useful scientificc data, satellites and manned aircraft have limitations in data frequency, process time, and real time re-tasking. Small low-cost unmanned aerial vehicles (UAVs) provide greater possibilities for personal scientic research than traditional remote sensing platforms. Precision aerial data requires an accurate vehicle dynamics model for controller development, robust flight characteristics, and fault tolerance. One method of developing a model is system identification (system ID). In this thesis system ID of a small low-cost fixed-wing T-tail UAV is conducted. The linerized longitudinal equations of motion are derived from first principles. Foundations of Recursive Least Squares (RLS) are presented along with RLS with an Error Filtering Online Learning scheme (EFOL). Sensors, data collection, data consistency checking, and data processing are described. Batch least squares (BLS) and BLS with EFOL are used to identify aerodynamic coecoefficients of the UAV. Results of these two methods with flight data are discussed.

  1. Application of low-cost adsorbents for dye removal--a review.

    PubMed

    Gupta, V K; Suhas

    2009-06-01

    Dyes are an important class of pollutants, and can even be identified by the human eye. Disposal of dyes in precious water resources must be avoided, however, and for that various treatment technologies are in use. Among various methods adsorption occupies a prominent place in dye removal. The growing demand for efficient and low-cost treatment methods and the importance of adsorption has given rise to low-cost alternative adsorbents (LCAs). This review highlights and provides an overview of these LCAs comprising natural, industrial as well as synthetic materials/wastes and their application for dyes removal. In addition, various other methods used for dye removal from water and wastewater are also complied in brief. From a comprehensive literature review, it was found that some LCAs, in addition to having wide availability, have fast kinetics and appreciable adsorption capacities too. Advantages and disadvantages of adsorbents, favourable conditions for particular adsorbate-adsorbent systems, and adsorption capacities of various low-cost adsorbents and commercial activated carbons as available in the literature are presented. Conclusions have been drawn from the literature reviewed, and suggestions for future research are proposed.

  2. An Innovative Porous Nanocomposite Material for the Removal of Phenolic Compounds from Aqueous Solutions.

    PubMed

    Turco, Antonio; Monteduro, Anna Grazia; Mazzotta, Elisabetta; Maruccio, Giuseppe; Malitesta, Cosimino

    2018-05-16

    Energy efficient, low-cost, user-friendly, and green methods for the removal of toxic phenolic compounds from aqueous solution are necessary for waste treatment in industrial applications. Herein we present an interesting approach for the utilization of oxidized carbon nanotubes (CNTs) in the removal of phenolic compounds from aqueous solution. Dried pristine CNTs were stably incorporated in a solid porous support of polydimethylsiloxane (PDMS) facilitating the handling during both oxidation process of the nanomaterial and uptake of phenolic compounds, and enabling their safe disposal, avoiding expensive post-treatment processes. The adsorption studies indicated that the materials can efficiently remove phenolic compounds from water with different affinities towards different phenolic compounds. Furthermore, the adsorption kinetics and isotherms were studied in detail. The experimental data of adsorption fitted well with Langmuir and Freundlich isotherms, and pseudo-second-order kinetics, and the results indicated that the adsorption process was controlled by a two-step intraparticle diffusion model. The incorporation of CNTs in polymeric matrices did not affect their functionality in phenol uptake. The material was also successfully used for the removal of phenolic compounds from agricultural waste, suggesting its possible application in the treatment of wastewater. Moreover, the surface of the material could be regenerated, decreasing treatment costs.

  3. COSMOS-rice technology abrogates the biotoxic effects of municipal solid waste incinerator residues.

    PubMed

    Guarienti, Michela; Cardozo, Sdenka Moscoso; Borgese, Laura; Lira, Gloria Rodrigo; Depero, Laura E; Bontempi, Elza; Presta, Marco

    2016-07-01

    Fly ashes generated by municipal solid waste incinerator (MSWI) are classified as hazardous waste and usually landfilled. For the sustainable reuse of these materials is necessary to reduce the resulting impact on human health and environment. The COSMOS-rice technology has been recently proposed for the treatment of fly ashes mixed with rice husk ash, to obtain a low-cost composite material with significant performances. Here, aquatic biotoxicity assays, including daphnidae and zebrafish embryo-based tests, were used to assess the biosafety efficacy of this technology. Exposure to lixiviated MSWI fly ash caused dose-dependent biotoxic effects on daphnidae and zebrafish embryos with alterations of embryonic development, teratogenous defects and apoptotic events. On the contrary, no biotoxic effects were observed in daphnidae and zebrafish embryos exposed to lixiviated COSMOS-rice material. Accordingly, whole-mount in situ hybridization analysis of the expression of various tissue-specific genes in zebrafish embryos provided genetic evidence about the ability of COSMOS-rice stabilization process to minimize the biotoxic effects of MSWI fly ash. These results demonstrate at the biological level that the newly developed COSMOS-rice technology is an efficient and cost-effective method to process MSWI fly ash, producing a biologically safe and reusable material. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Platelet-rich plasma injection is more effective than hyaluronic acid in the treatment of knee osteoarthritis.

    PubMed

    Say, F; Gürler, D; Yener, K; Bülbül, M; Malkoc, M

    2013-01-01

    There is increasing use of platelet-rich plasma (PRP) in orthopaedics as it is a simple, cheap and minimally invasive technique. This study aimed to compare the effects of the use of PRP and hyaluronic acid (HA) injections in the knee of patients diagnosed with and being followed-up for degenerative arthritis. This prospective study included 90 patients with complaints of knee pain with findings of mild or moderate degenerative arthritis. In the PRP group (n=45), one intra-articular injection was applied and in the HA group (n=45), three doses of intra-articular injection were applied. Clinical evaluation was made by Knee Injury and Osteoarthritis Outcome Score (KOOS) and a visual pain scale. No severe adverse events was observed. Statistically significant better results in the KOOS score and visual pain scale was determined in PRP group than HA group at 3 months and 6 months follow up. The cost of the application for the PRP group was lower than that of the HA group. The results of this study have shown the application of single dose PRP to be a safe, effective and low-cost method for treating OA. However, further studies are required for a more clear result.

  5. Green Synthesis of InP/ZnS Core/Shell Quantum Dots for Application in Heavy-Metal-Free Light-Emitting Diodes.

    PubMed

    Kuo, Tsung-Rong; Hung, Shih-Ting; Lin, Yen-Ting; Chou, Tzu-Lin; Kuo, Ming-Cheng; Kuo, Ya-Pei; Chen, Chia-Chun

    2017-09-19

    Quantum dot light-emitting diodes (QD-LEDs) have been considered as potential display technologies with the characterizations of high color purity, flexibility, transparency, and cost efficiency. For the practical applications, the development of heavy-metal-free QD-LEDs from environment-friendly materials is the most important issue to reduce the impacts on human health and environmental pollution. In this work, heavy-metal-free InP/ZnS core/shell QDs with different fluorescence were prepared by green synthesis method with low cost, safe, and environment-friendly precursors. The InP/ZnS core/shell QDs with maximum fluorescence peak at ~ 530 nm, superior fluorescence quantum yield of 60.1%, and full width at half maximum of 55 nm were applied as an emission layer to fabricate multilayered QD-LEDs. The multilayered InP/ZnS core/shell QD-LEDs showed the turn-on voltage at ~ 5 V, the highest luminance (160 cd/m 2 ) at 12 V, and the external quantum efficiency of 0.223% at 6.7 V. Overall, the multilayered InP/ZnS core/shell QD-LEDs reveal potential to be the heavy-metal-free QD-LEDs for future display applications.

  6. Essentials of skin laceration repair.

    PubMed

    Forsch, Randall T

    2008-10-15

    Skin laceration repair is an important skill in family medicine. Sutures, tissue adhesives, staples, and skin-closure tapes are options in the outpatient setting. Physicians should be familiar with various suturing techniques, including simple, running, and half-buried mattress (corner) sutures. Although suturing is the preferred method for laceration repair, tissue adhesives are similar in patient satisfaction, infection rates, and scarring risk in low skin-tension areas and may be more cost-effective. The tissue adhesive hair apposition technique also is effective in repairing scalp lacerations. The sting of local anesthesia injections can be lessened by using smaller gauge needles, administering the injection slowly, and warming or buffering the solution. Studies have shown that tap water is safe to use for irrigation, that white petrolatum ointment is as effective as antibiotic ointment in postprocedure care, and that wetting the wound as early as 12 hours after repair does not increase the risk of infection. Patient education and appropriate procedural coding are important after the repair.

  7. Microemulsion-based lycopene extraction: Effect of surfactants, co-surfactants and pretreatments.

    PubMed

    Amiri-Rigi, Atefeh; Abbasi, Soleiman

    2016-04-15

    Lycopene is a potent antioxidant that has received extensive attention recently. Due to the challenges encountered with current methods of lycopene extraction using hazardous solvents, industry calls for a greener, safer and more efficient process. The main purpose of present study was application of microemulsion technique to extract lycopene from tomato pomace. In this respect, the effect of eight different surfactants, four different co-surfactants, and ultrasound and enzyme pretreatments on lycopene extraction efficiency was examined. Experimental results revealed that application of combined ultrasound and enzyme pretreatments, saponin as a natural surfactant, and glycerol as a co-surfactant, in the bicontinuous region of microemulsion was the optimal experimental conditions resulting in a microemulsion containing 409.68±0.68 μg/glycopene. The high lycopene concentration achieved, indicates that microemulsion technique, using a low-cost natural surfactant could be promising for a simple and safe separation of lycopene from tomato pomace and possibly from tomato industrial wastes. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Eco-friendly plasmonic sensors: using the photothermal effect to prepare metal nanoparticle-containing test papers for highly sensitive colorimetric detection.

    PubMed

    Tseng, Shao-Chin; Yu, Chen-Chieh; Wan, Dehui; Chen, Hsuen-Li; Wang, Lon Alex; Wu, Ming-Chung; Su, Wei-Fang; Han, Hsieh-Cheng; Chen, Li-Chyong

    2012-06-05

    Convenient, rapid, and accurate detection of chemical and biomolecules would be a great benefit to medical, pharmaceutical, and environmental sciences. Many chemical and biosensors based on metal nanoparticles (NPs) have been developed. However, as a result of the inconvenience and complexity of most of the current preparation techniques, surface plasmon-based test papers are not as common as, for example, litmus paper, which finds daily use. In this paper, we propose a convenient and practical technique, based on the photothermal effect, to fabricate the plasmonic test paper. This technique is superior to other reported methods for its rapid fabrication time (a few seconds), large-area throughput, selectivity in the positioning of the NPs, and the capability of preparing NP arrays in high density on various paper substrates. In addition to their low cost, portability, flexibility, and biodegradability, plasmonic test paper can be burned after detecting contagious biomolecules, making them safe and eco-friendly.

  9. ANTI-VIRAL EFFECTS OF MEDICINAL PLANTS IN THE MANAGEMENT OF DENGUE: A SYSTEMATIC REVIEW

    PubMed Central

    Frederico, Éric Heleno Freira Ferreira; Cardoso, André Luiz Bandeira Dionísio; Moreira-Marconi, Eloá; de Sá-Caputo, Danúbia da Cunha; Guimarães, Carlos Alberto Sampaio; Dionello, Carla da Fontoura; Morel, Danielle Soares; Paineiras-Domingos, Laisa Liane; de Souza, Patricia Lopes; Brandão-Sobrinho-Neto, Samuel; Carvalho-Lima, Rafaelle Pacheco; Guedes-Aguiar, Eliane de Oliveira; Costa-Cavalcanti, Rebeca Graça; Kutter, Cristiane Ribeiro; Bernardo-Filho, Mario

    2017-01-01

    Background: Dengue is considered as an important arboviral disease. Safe, low-cost, and effective drugs that possess inhibitory activity against dengue virus (DENV) are mostly needed to try to combat the dengue infection worldwide. Medicinal plants have been considered as an important alternative to manage several diseases, such as dengue. As authors have demonstrated the antiviral effect of medicinal plants against DENV, the aim of this study was to review systematically the published research concerning the use of medicinal plants in the management of dengue using the PubMed database. Materials and Methods: Search and selection of publications were made using the PubMed database following the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA statement). Results: Six publications met the inclusion criteria and were included in the final selection after thorough analysis. Conclusion: It is suggested that medicinal plants’ products could be used as potential anti-DENV agents. PMID:28740942

  10. Policy considerations for improving influenza vaccination rates among pregnant women.

    PubMed

    Mollard, Elizabeth K; Guenzel, Nicholas; Brown, Peggy A; Keeler, Heidi J; Cramer, Mary E

    2014-01-01

    Influenza exposure during pregnancy can cause severe health problems for both the mother and her offspring, including an increased risk of mortality. Influenza vaccination during all trimesters of pregnancy is safe and effective, and recommended by professional organizations such as the American College of Obstetrics and Gynecology. Despite these recommendations, the U.S. vaccination rates remain low in this high-risk population. A policy analysis based on the five-part method identified by Teitelbaum and Wilensky () addresses factors to consider in identifying the best voluntary policy options to improve the vaccination rates. The authors provide discussion of the background, landscape, and stakeholder interests and the pros and cons of two voluntary policy options to increase vaccination. The policy options include: (a) financial incentives for providers and (b) an education emphasis for providers and staff. The authors conclude that based on considerations of cost, provider preference, and practicality of implementation, a continuing educational intervention is the preferred policy venue to increase vaccination rates. © 2014 Wiley Periodicals, Inc.

  11. Behaviour of one-step spray-coated carbon nanotube supercapacitor in ambient light harvester circuit with printed organic solar cell and electrochromic display

    PubMed Central

    Tuukkanen, Sampo; Välimäki, Marja; Lehtimäki, Suvi; Vuorinen, Tiina; Lupo, Donald

    2016-01-01

    A printed energy harvesting and storage circuit powered by ambient office lighting and its use to power a printed display is reported. The autonomous device is composed of three printed electronic components: an organic photovoltaic module, a carbon-nanotubes-only supercapacitor and an electrochromic display element. Components are fabricated from safe and environmentally friendly materials, and have been fabricated using solution processing methods, which translate into low-cost and high-throughput manufacturing. A supercapacitor made of spray-coated carbon nanotube based ink and aqueous NaCl electrolyte was charged using a printed organic photovoltaic module exposed to office lighting conditions. The supercapacitor charging rate, self-discharge rate and display operation were studied in detail. The supercapacitor self-discharge rate was found to depend on the charging rate. The fully charged supercapacitor was used as a power source to run the electrochromic display over 50 times. PMID:26957019

  12. High impact mass drops from helicopter: A new active seismic source method applied in an active volcanic setting

    NASA Astrophysics Data System (ADS)

    Jolly, A. D.; Chardot, L.; Neuberg, J.; Fournier, N.; Scott, B. J.; Sherburn, S.

    2012-06-01

    We obtain estimates of the seismic velocity and attenuation for White Island volcano by use of high-impact sand-bag drops from helicopter. Three drops were attempted, two at either end of a 6-station linear array within the crater floor, and the third in the volcano's crater lake. The bags were dropped from ˜310-380 m height and contained ˜700 kg of sand. The impact velocity was estimated at ˜60-70 m/s yielding a kinetic energy of about 106 Nm, giving P-wave onsets to a distance of ˜1 km. We obtained a seismic velocity estimate of Vp = 1.2 km/s for the unconsolidated crater floor and Vp = 2.2 km/s for rays traversing through consolidated rock outside the crater. Attenuation was very strong (Q < 10) for both consolidated and unconsolidated parts of the volcano. This trial shows that low cost helicopter mass drops can be successfully applied to safely determine sub-surface properties at hazardous volcanoes.

  13. User preferences and willingness to pay for safe drinking water: Experimental evidence from rural Tanzania.

    PubMed

    Burt, Zachary; Njee, Robert M; Mbatia, Yolanda; Msimbe, Veritas; Brown, Joe; Clasen, Thomas F; Malebo, Hamisi M; Ray, Isha

    2017-01-01

    Almost half of all deaths from drinking microbiologically unsafe water occur in Sub-Saharan Africa. Household water treatment and safe storage (HWTS) systems, when consistently used, can provide safer drinking water and improve health. Social marketing to increase adoption and use of HWTS depends both on the prices of and preferences for these systems. This study included 556 households from rural Tanzania across two low-income districts with low-quality water sources. Over 9 months in 2012 and 2013, we experimentally evaluated consumer preferences for six "low-cost" HWTS options, including boiling, through an ordinal ranking protocol. We estimated consumers' willingness to pay (WTP) for these options, using a modified auction. We allowed respondents to pay for the durable HWTS systems with cash, chickens or mobile money; a significant minority chose chickens as payment. Overall, our participants favored boiling, the ceramic pot filter and, where water was turbid, PuR™ (a combined flocculant-disinfectant). The revealed WTP for all products was far below retail prices, indicating that significant scale-up may need significant subsidies. Our work will inform programs and policies aimed at scaling up HWTS to improve the health of resource-constrained communities that must rely on poor-quality, and sometimes turbid, drinking water sources. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Lower currents: a new choice for routine testing.

    PubMed

    Backes, John

    2007-01-01

    U.S. NFPA and AAMI standards both recommend a 10A ground bond test and, as has been described above, both 25A and 200mA are also recommended internationally as valid test currents for the in-service testing and inspection of medical electrical equipment. The reality is that both high and low test currents are of value to biomedical engineers and technicians in different circumstances. For benchtop testing in a workshop environment, where required test currents can be applied safely, then it seems likely that high current testing will remain the preferred option. However, for in-service test applications, where the portability and versatility of the tester is a key requirement, modern electronic technology now means that low current testing can now be applied effectively and safely. In summary, by using a low-energy, high current pulse prior to 200 mA test current, the lower test current is preferred for routine field maintenance as this can mean: Increased safety of the operator. Reduced risk of damage to the in-service medical equipment. Smaller test instruments to include valid ground bond measurements. Battery operated test equipment. Increased flexibility of the test engineer due to lightweight test equipment. Cost reduction due to reduced down time of medical equipment. More economical availability of test equipment.

  15. Recent Enhancements to the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Kilgore, W. A.; Balakrishna, S.; Bobbitt, C. W.; Underwood, P.

    2003-01-01

    The National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the restoration of reliability and improved performance of the heat exchanger systems resulting in the expansion of the NTF air operations envelope. Additionally, results are presented from a continued effort to reduce model dynamics through the use of a new stiffer balance and sting

  16. Addition of CFCl 3 to Aromatic Aldehydes via in Situ Grignard Reaction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barkakaty, Balaka; Talukdar, Bandana; Lokitz, Bradley

    In the case of synthetic modification of trichlorofluoromethane (CFCl 3) to non-volatile and useful fluorinated precursors, we realized that it is a cost-effective and an environmentally benign strategy for the safe consumption/destruction of the ozone depleting potential of the reagent. In our report, we present a novel method for in situ Grignard reaction using magnesium powder and CFCl 3 for synthesis of dichlorofluoromethyl aromatic alcohols.

  17. Addition of CFCl 3 to Aromatic Aldehydes via in Situ Grignard Reaction

    DOE PAGES

    Barkakaty, Balaka; Talukdar, Bandana; Lokitz, Bradley

    2015-08-18

    In the case of synthetic modification of trichlorofluoromethane (CFCl 3) to non-volatile and useful fluorinated precursors, we realized that it is a cost-effective and an environmentally benign strategy for the safe consumption/destruction of the ozone depleting potential of the reagent. In our report, we present a novel method for in situ Grignard reaction using magnesium powder and CFCl 3 for synthesis of dichlorofluoromethyl aromatic alcohols.

  18. Nitrogen Dioxide Sterilization in Low-Resource Environments: A Feasibility Study

    PubMed Central

    Avasthi, Trisha; Trilling, Ariel

    2015-01-01

    Access to sterilization is a critical need for global healthcare, as it is one of the prerequisites for safe surgical care. Lack of sterilization capability has driven up healthcare infection rates as well as limited access to healthcare, especially in low-resource environments. Sterilization technology has for the most part been static and none of the established sterilization methods has been so far successfully adapted for use in low-resource environments on a large scale. It is evident that healthcare facilities in low-resource settings require reliable, deployable, durable, affordable, easily operable sterilization equipment that can operate independently of scarce resources. Recently commercialized nitrogen dioxide (NO2) sterilization technology was analyzed and adapted into a form factor suitable for use in low-resource environments. Lab testing was conducted in microbiological testing facilities simulating low-resource environments and in accordance with the requirements of the international sterilization standard ANSI/AAMI/ISO 14937 to assess effectiveness of the device and process. The feasibility of a portable sterilizer based on nitrogen dioxide has been demonstrated, showing that sterilization of medical instruments can occur in a form factor suitable for use in low-resource environments. If developed and deployed, NO2 sterilization technology will have the twin benefits of reducing healthcare acquired infections and limiting a major constraint for access to surgical care on a global scale. Additional benefits are achieved in reducing costs and biohazard waste generated by current health care initiatives that rely primarily on disposable kits, increasing the effectiveness and outreach of these initiatives. PMID:26098905

  19. Flight-Test Evaluation of Flutter-Prediction Methods

    NASA Technical Reports Server (NTRS)

    Lind, RIck; Brenner, Marty

    2003-01-01

    The flight-test community routinely spends considerable time and money to determine a range of flight conditions, called a flight envelope, within which an aircraft is safe to fly. The cost of determining a flight envelope could be greatly reduced if there were a method of safely and accurately predicting the speed associated with the onset of an instability called flutter. Several methods have been developed with the goal of predicting flutter speeds to improve the efficiency of flight testing. These methods include (1) data-based methods, in which one relies entirely on information obtained from the flight tests and (2) model-based approaches, in which one relies on a combination of flight data and theoretical models. The data-driven methods include one based on extrapolation of damping trends, one that involves an envelope function, one that involves the Zimmerman-Weissenburger flutter margin, and one that involves a discrete-time auto-regressive model. An example of a model-based approach is that of the flutterometer. These methods have all been shown to be theoretically valid and have been demonstrated on simple test cases; however, until now, they have not been thoroughly evaluated in flight tests. An experimental apparatus called the Aerostructures Test Wing (ATW) was developed to test these prediction methods.

  20. Reliability Assessment for Low-cost Unmanned Aerial Vehicles

    NASA Astrophysics Data System (ADS)

    Freeman, Paul Michael

    Existing low-cost unmanned aerospace systems are unreliable, and engineers must blend reliability analysis with fault-tolerant control in novel ways. This dissertation introduces the University of Minnesota unmanned aerial vehicle flight research platform, a comprehensive simulation and flight test facility for reliability and fault-tolerance research. An industry-standard reliability assessment technique, the failure modes and effects analysis, is performed for an unmanned aircraft. Particular attention is afforded to the control surface and servo-actuation subsystem. Maintaining effector health is essential for safe flight; failures may lead to loss of control incidents. Failure likelihood, severity, and risk are qualitatively assessed for several effector failure modes. Design changes are recommended to improve aircraft reliability based on this analysis. Most notably, the control surfaces are split, providing independent actuation and dual-redundancy. The simulation models for control surface aerodynamic effects are updated to reflect the split surfaces using a first-principles geometric analysis. The failure modes and effects analysis is extended by using a high-fidelity nonlinear aircraft simulation. A trim state discovery is performed to identify the achievable steady, wings-level flight envelope of the healthy and damaged vehicle. Tolerance of elevator actuator failures is studied using familiar tools from linear systems analysis. This analysis reveals significant inherent performance limitations for candidate adaptive/reconfigurable control algorithms used for the vehicle. Moreover, it demonstrates how these tools can be applied in a design feedback loop to make safety-critical unmanned systems more reliable. Control surface impairments that do occur must be quickly and accurately detected. This dissertation also considers fault detection and identification for an unmanned aerial vehicle using model-based and model-free approaches and applies those algorithms to experimental faulted and unfaulted flight test data. Flight tests are conducted with actuator faults that affect the plant input and sensor faults that affect the vehicle state measurements. A model-based detection strategy is designed and uses robust linear filtering methods to reject exogenous disturbances, e.g. wind, while providing robustness to model variation. A data-driven algorithm is developed to operate exclusively on raw flight test data without physical model knowledge. The fault detection and identification performance of these complementary but different methods is compared. Together, enhanced reliability assessment and multi-pronged fault detection and identification techniques can help to bring about the next generation of reliable low-cost unmanned aircraft.

  1. Safe and cost-effective protocol for shipment of samples from Foot-and-Mouth Disease suspected cases for laboratory diagnostic.

    PubMed

    Romey, A; Relmy, A; Gorna, K; Laloy, E; Zientara, S; Blaise-Boisseau, S; Bakkali Kassimi, L

    2018-02-01

    An essential step towards the global control and eradication of foot-and-mouth disease (FMD) is the identification of circulating virus strains in endemic regions to implement adequate outbreak control measures. However, due to the high biological risk and the requirement for biological samples to be shipped frozen, the cost of shipping samples becomes one of major obstacles hindering submission of suspected samples to reference laboratories for virus identification. In this study, we report the development of a cost-effective and safe method for shipment of FMD samples. The protocol is based on the inactivation of FMD virus (FMDV) on lateral flow device (LFD, penside test routinely used in the field for rapid immunodetection of FMDV), allowing its subsequent detection and typing by RT-PCR and recovery of live virus upon RNA transfection into permissive cells. After live FMDV collection onto LFD strip and soaking in 0.2% citric acid solution, the virus is totally inactivated. Viral RNA is still detectable by real-time RT-PCR following inactivation, and the virus strain can be characterized by sequencing of the VP1 coding region. In addition, live virus can be rescued by transfecting RNA extract from treated LFD into cells. This protocol should help promoting submission of FMD suspected samples to reference laboratories (by reducing the cost of sample shipping) and thus characterization of FMDV strains circulating in endemic regions. © 2017 Blackwell Verlag GmbH.

  2. Pathways and consequences of unsafe abortion: a comparison among women with complications after induced and spontaneous abortions in Madhya Pradesh, India.

    PubMed

    Banerjee, Sushanta K; Andersen, Kathryn L; Warvadekar, Janardan

    2012-09-01

    This study aimed to understand women's pathways of seeking care for postabortion complications in Madhya Pradesh, India. The study recruited 786 women between July and November 2007. Data were collected on service provision, abortion-related complications, care-seeking behavior, knowledge about abortion legality and availability, methods used, symptoms, referral source, and out-of-pocket costs. Women seeking care for complications from induced abortion followed more complex pathways to treatment than women with complications of spontaneous abortion. More complex pathways were associated with higher out-of-pocket costs. Improving community awareness on legal aspects, safe abortion methods, and trained providers are necessary to reduce morbidity associated with unsafe abortion. Copyright © 2012 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Epidemiology and medical cost of hospitalization due to rotavirus gastroenteritis among children under 5 years of age in the central-east of Tunisia.

    PubMed

    Soltani, M S; Salah, A Ben; Bouanene, I; Trabelsi, A; Sfar, M T; Harbi, A; Gueddiche, M N; Farhat, E Ben

    2015-09-28

    Data on the economic burden of rotavirus infection in Tunisia are needed to inform the decision to include rotavirus in routine childhood immunizations. This study aimed to describe the epidemiological profile of rotavirus disease in central-east Tunisia and to estimate its hospital cost. In the first stage - the prospective collection of epidemiological data - we enrolled all patients < 5 years old who were hospitalized for acute diarrhoea at 5 university paediatric departments in central-east Tunisia during the period 2009-2011. Rotavirus was responsible for 65 (23.3%) of the 279 cases enrolled. In the second stage, cost data were collected retrospectively using an activity-based costing method from the medical records of the children who were positively diagnosed with rotavirus. The average cost of care per child was TD 433 (SD 134). This is a significant economic burden in Tunisia, where a safe and effective vaccine is available but not yet introduced to the immunization schedule.

  4. Reduction of Escherichia Coli using ceramic disk filter decorated by nano-TiO2: A low-cost solution for household water purification.

    PubMed

    He, Yuan; Huang, Guohe; An, Chunjiang; Huang, Jing; Zhang, Peng; Chen, Xiujuan; Xin, Xiaying

    2018-03-01

    Lack of access to safe water is a challenge in many developing countries, especially in rural areas. It is urgent to develop cost-effective water purification technologies to guarantee drinking water safety in these areas. The present study investigated the reduction of Escherichia coli (E. coli) using ceramic disk filters (CDFs) decorated by nano-TiO 2. The production of CDFs coated with nano-TiO 2 in terms of rice-husk ratio, rice-husk particle size, heating hold time and nano-TiO 2 mass fraction was optimized. The results show that the optimum conditions for CDFs with nano-TiO 2 coating included rice-husk ratio of 29.03%, rice-husk particle size of 0.28mm, heating hold time of 1.41h and nano-TiO 2 mass fraction of 2.21%. Additionally, the morphological and crystal phase characteristics of CDFs were revealed after the decoration by nano-TiO 2 . The effects of temperature, influent E. coli concentration, lamp power and their interactions were explored via factorial analysis. Influent E. coli concentration and lamp power had significant effects on E. coli removal efficiency. This study provided the solid theoretical support for understanding the production and bacteria inactivation relevant to CDFs impregnated with nano-TiO 2 . The results have important implications for finding a safe and cost-effective approach to solve drinking water problems in developing countries. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. (abstract) Oblique Insonification Ultrasonic NDE of Composite Materials for Space Applications

    NASA Technical Reports Server (NTRS)

    Bar-Cohen, Y.; Lih, S. S.; Mal, A. K.

    1997-01-01

    In recent years, a great deal of research has been exerted to developing NDE methods for the characterization of the material properties of composites as well as other space structural materials. The need for information about such parameters as the elastic properties, density, and thickness are critical to the safe design and operation of such structural materials. Ultrasonics using immersion methods has played an important role in these efforts due to its capability, cost effectiveness, and ease of use. The authors designed a series of ultrasonic oblique insonification experiments in order to develop a practical field applicable NDE method for space structures.

  6. Development of a non-invasive LED based device for adipose tissue thickness measurements in vivo

    NASA Astrophysics Data System (ADS)

    Volceka, K.; Jakovels, D.; Arina, Z.; Zaharans, J.; Kviesis, E.; Strode, A.; Svampe, E.; Ozolina-Moll, L.; Butnere, M. M.

    2012-06-01

    There are a number of techniques for body composition assessment in clinics and in field-surveys, but in all cases the applied methods have advantages and disadvantages. High precision imaging methods are available, though expensive and non-portable, however, the methods devised for the mass population, often suffer from the lack of precision. Therefore, the development of a safe, mobile, non-invasive, optical method that would be easy to perform, precise and low-cost, but also would offer an accurate assessment of subcutaneous adipose tissue (SAT) both in lean and in obese persons is required. Thereof, the diffuse optical spectroscopy is advantageous over the aforementioned techniques. A prototype device using an optical method for measurement of the SAT thickness in vivo has been developed. The probe contained multiple LEDs (660nm) distributed at various distances from the photo-detector which allow different light penetration depths into the subcutaneous tissue. The differences of the reflected light intensities were used to create a non-linear model, and the computed values were compared with the corresponding thicknesses of SAT, assessed by B-mode ultrasonography. The results show that with the optical system used in this study, accurate results of different SAT thicknesses can be obtained, and imply a further potential for development of multispectral optical system to observe changes of SAT thickness as well as to determine the percentage of total body fat.

  7. Development of a low-cost double rotor axial flux motor with soft magnetic composite and ferrite permanent magnet materials

    NASA Astrophysics Data System (ADS)

    Liu, Chengcheng; Zhu, Jianguo; Wang, Youhua; Guo, Youguang; Lei, Gang; Liu, Xiaojing

    2015-05-01

    This paper proposes a low-cost double rotor axial flux motor (DRAFM) with low cost soft magnetic composite (SMC) core and ferrite permanent magnets (PMs). The topology and operating principle of DRAFM and design considerations for best use of magnetic materials are presented. A 905 W 4800 rpm DRAFM is designed for replacing the high cost NdFeB permanent magnet synchronous motor (PMSM) in a refrigerator compressor. By using the finite element method, the electromagnetic parameters and performance of the DRAFM operated under the field oriented control scheme are calculated. Through the analysis, it is shown that that the SMC and ferrite PM materials can be good candidates for low-cost electric motor applications.

  8. Reliability and Maintainability Engineering - A Major Driver for Safety and Affordability

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.

    2011-01-01

    The United States National Aeronautics and Space Administration (NASA) is in the midst of an effort to design and build a safe and affordable heavy lift vehicle to go to the moon and beyond. To achieve that, NASA is seeking more innovative and efficient approaches to reduce cost while maintaining an acceptable level of safety and mission success. One area that has the potential to contribute significantly to achieving NASA safety and affordability goals is Reliability and Maintainability (R&M) engineering. Inadequate reliability or failure of critical safety items may directly jeopardize the safety of the user(s) and result in a loss of life. Inadequate reliability of equipment may directly jeopardize mission success. Systems designed to be more reliable (fewer failures) and maintainable (fewer resources needed) can lower the total life cycle cost. The Department of Defense (DOD) and industry experience has shown that optimized and adequate levels of R&M are critical for achieving a high level of safety and mission success, and low sustainment cost. Also, lessons learned from the Space Shuttle program clearly demonstrated the importance of R&M engineering in designing and operating safe and affordable launch systems. The Challenger and Columbia accidents are examples of the severe impact of design unreliability and process induced failures on system safety and mission success. These accidents demonstrated the criticality of reliability engineering in understanding component failure mechanisms and integrated system failures across the system elements interfaces. Experience from the shuttle program also shows that insufficient Reliability, Maintainability, and Supportability (RMS) engineering analyses upfront in the design phase can significantly increase the sustainment cost and, thereby, the total life cycle cost. Emphasis on RMS during the design phase is critical for identifying the design features and characteristics needed for time efficient processing, improved operational availability, and optimized maintenance and logistic support infrastructure. This paper discusses the role of R&M in a program acquisition phase and the potential impact of R&M on safety, mission success, operational availability, and affordability. This includes discussion of the R&M elements that need to be addressed and the R&M analyses that need to be performed in order to support a safe and affordable system design. The paper also provides some lessons learned from the Space Shuttle program on the impact of R&M on safety and affordability.

  9. Solidification as low cost technology prior to land filling of industrial hazardous waste sludge.

    PubMed

    El-Sebaie, O; Ahmed, M; Ramadan, M

    2000-01-01

    The aim of this study is to stabilize and solidify two different treated industrial hazardous waste sludges, which were selected from factories situated close to Alexandria. They were selected to ensure their safe transportation and landfill disposal by reducing their potential leaching of hazardous elements, which represent significant threat to the environment, especially the quality of underground water. The selected waste sludges have been characterized. Ordinary Portland Cement (OPC), Cement Kiln Dust (CKD) from Alexandria Portland Cement Company, and Calcium Sulphate as a by-product from the dye industry were used as potential solidification additives to treat the selected treated waste sludges from tanning and dyes industry. Waste sludges as well as the solidified wastes have been leach-tested, using the General Acid Neutralization Capacity (GANC) procedure. Concentration of concerning metals in the leachates was determined to assess changes in the mobility of major contaminants. The treated tannery waste sludge has an acid neutralization capacity much higher than that of the treated dyes waste sludge. Experiment results demonstrated the industrial waste sludge solidification mix designs, and presented the reduction of contaminant leaching from two types of waste sludges. The main advantages of solidification are that it is simple and low cost processing which includes readily available low cost solidification additives that will convert industrial hazardous waste sludges into inert materials.

  10. Evaluation of Low-Cost Mitigation Measures Implemented to Improve Air Quality in Nursery and Primary Schools

    PubMed Central

    Sá, Juliana P.; Branco, Pedro T. B. S.; Alvim-Ferraz, Maria C. M.; Martins, Fernando G.; Sousa, Sofia I. V.

    2017-01-01

    Indoor air pollution mitigation measures are highly important due to the associated health impacts, especially on children, a risk group that spends significant time indoors. Thus, the main goal of the work here reported was the evaluation of mitigation measures implemented in nursery and primary schools to improve air quality. Continuous measurements of CO2, CO, NO2, O3, CH2O, total volatile organic compounds (VOC), PM1, PM2.5, PM10, Total Suspended Particles (TSP) and radon, as well as temperature and relative humidity were performed in two campaigns, before and after the implementation of low-cost mitigation measures. Evaluation of those mitigation measures was performed through the comparison of the concentrations measured in both campaigns. Exceedances to the values set by the national legislation and World Health Organization (WHO) were found for PM2.5, PM10, CO2 and CH2O during both indoor air quality campaigns. Temperature and relative humidity values were also above the ranges recommended by American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). In general, pollutant concentrations measured after the implementation of low-cost mitigation measures were significantly lower, mainly for CO2. However, mitigation measures were not always sufficient to decrease the pollutants’ concentrations till values considered safe to protect human health. PMID:28561795

  11. Innovative Airbreathing Propulsion Concepts for Access to Space

    NASA Technical Reports Server (NTRS)

    Whitlow, Jr., Woodrow; Blech, Richard A.; Blankson, Isaiah M.

    2001-01-01

    This paper will present technologies and concepts for novel aeropropulsion systems. These technologies will enhance the safety of operations, reduce life cycle costs, and contribute to reduced costs of air travel and access to space. One of the goals of the NASA program is to reduce the carbon-dioxide emissions of aircraft engines. Engine concepts that use highly efficient fuel cell/electric drive technologies in hydrogen-fueled engines will be presented in the proposed paper. Carbon-dioxide emissions will be eliminated by replacing hydrocarbon fuel with hydrogen, and reduce NOx emissions through better combustion process control. A revolutionary exoskeletal engine concept, in which the engine drum is rotated, will be shown. This concept has the potential to allow a propulsion system that can be used for subsonic through hypersonic flight. Dual fan concepts that have ultra-high bypass ratios, low noise, and low drag will be presented. Flow-controlled turbofans and control-configured turbofans also will be discussed. To increase efficiency, a system of microengines distributed along lifting surfaces and on the fuselage is being investigated. This concept will be presented in the paper. Small propulsion systems for affordable, safe personal transportation vehicles will be discussed. These low-oil/oilless systems use technologies that enable significant cost and weight reductions. Pulse detonation engine-based hybrid-cycle and combined-cycle propulsion systems for aviation and space access will be presented.

  12. Looped suture versus stapler device in pediatric laparoscopic appendectomy: a comparative outcomes and intraoperative cost analysis.

    PubMed

    Parikh, Punam P; Tashiro, Jun; Wagenaar, Amy E; Curbelo, Miosotys; Perez, Eduardo A; Neville, Holly L; Hogan, Anthony R; Sola, Juan E

    2018-04-01

    Appendiceal ligation during pediatric laparoscopic appendectomy (LA) may be performed using looped suture versus stapler. Controversy regarding the utility of either method exists. Clinical outcomes and cost analysis of LA with both methods were compared. All pediatric LA were performed from fiscal years 2013 and 2014 by two pediatric surgeons. While one surgeon used looped suture, the other used stapler exclusively. chi-Square tests were performed to analyze associations. Two hundred thirty-eight cases were analyzed where looped suture versus stapler LA was performed in 46% and 54% of patients, respectively. Operating room costs were $317.10 and $707.12/person for looped suture and stapler LA, respectively (P<0.0001). Difference in cost of $390.02/person was attributed solely to ligation type. On bivariate analysis, rate of in-hospital complications, length of stay, return-to-ER and readmission within 30 days did not significantly differ between groups. A comparative analysis of looped suture versus stapler device during LA for pediatric appendicitis revealed that postoperative complications, length of stay, ER visits and readmissions were not significantly different. Looped suture LA was significantly more cost efficient than stapler LA. In pediatric appendicitis, appendiceal ligation during LA may be performed safely and cost effectively with looped suture versus stapler. Cost effectiveness LEVEL OF EVIDENCE: III. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Natural Carbonation of Peridotite and Applications for Carbon Storage

    NASA Astrophysics Data System (ADS)

    Streit, E.; Kelemen, P.; Matter, J.

    2009-05-01

    Natural carbonation of peridotite in the Samail Ophiolite of Oman is surprisingly rapid and could be further enhanced to provide a safe, permanent method of CO2 storage through in situ formation of carbonate minerals. Carbonate veins form by low-temperature reaction between peridotite and groundwater in a shallow weathering horizon. Reaction with peridotite drives up the pH of the water, and extensive travertine terraces form where this groundwater emerges at the surface in alkaline springs. The potential sink for CO2 in peridotite is enormous: adding 1wt% CO2 to the peridotite in Oman could consume 1/4 of all atmospheric carbon, and several peridotite bodies of comparable size exist throughout the world. Thus carbonation rate and cost, not reservoir size, are the limiting factors on the usefulness of in situ mineral carbonation of peridotite for carbon storage. The carbonate veins in Oman are much younger than previously believed, yielding average 14C ages of 28,000 years. Age data plus estimated volumes of carbonate veins and terraces suggest 10,000 to 100,000 tons per year of CO2 are consumed by these peridotite weathering reactions in Oman. This rate can be enhanced by drilling, hydraulic fracture, injecting CO2-rich fluid, and increasing reaction temperature. Drilling and hydraulic fracture can increase volume of peridotite available for reaction. Additional fracture may occur due to the solid volume increase of the carbonation reaction, and field observations suggest that such reaction-assisted fracture may be responsible for hierarchical carbonate vein networks in peridotite. Natural carbonation of peridotite in Oman occurs at low pCO2, resulting in partial carbonation of peridotite, forming magnesite and serpentine. Raising pCO2 increases carbonation efficiency, forming of magnesite + talc, or at complete carbonation, magnesite + quartz, allowing ˜30wt% CO2 to be added to the peridotite. Increasing the temperature to 185°C can improve the reaction rate by a factor of more than 100,000. Thermal modeling suggests that after an initial heating stage, CO2-rich fluids injected at relatively low temperature can be heated by exothermic carbonation reactions, offsetting diffusive heat loss to maintain optimal temperatures for rapid carbonation without additional energy input. With these enhancements, in situ carbonation could consume more than 1 billion tons of CO2 per cubic kilometer of peridotite per year. Costs associated with this method include drilling, hydraulic fracture, initial heating, CO2 capture and transport, fluid injection and monitoring. The techniques for drilling, fracture and injection are routinely used by oil companies. Compared with other carbon storage methods, in situ mineral carbonation has several advantages. It offers permanent storage that is safer and easier to monitor than storage of CO2-rich fluids in porous underground reservoirs or in the ocean. It may also be less costly than ex situ mineral carbonation, which requires quarrying and transportation of peridotite, grinding and heat treatment, reactions in pressure vessels at elevated temperature, production of catalysts, and disposal of carbonated material. An alternative method, carbonation by reaction of offshore peridotite with shallow seawater rather than CO2-rich fluids, would consume less CO2, but would avoid the costs of CO2 capture and transport inherent in other CCS methods. Drilling to depths where rocks are already close to the optimal carbonation temperature would avoid pre-heating costs and circulate water by thermal convection rather than pumping fluids.

  14. The challenges of sustainable access to safe drinking water in rural areas of developing countries: case of Zawtar El-Charkieh, Southern Lebanon.

    PubMed

    Massoud, May A; Al-Abady, Abdolmonim; Jurdi, Mey; Nuwayhid, Iman

    2010-06-01

    Adequate and safe water is important for human health and well-being, economic production, and sustainable development. Failure to ensure the safety of drinking water may expose the community to the risk of outbreaks of waterborne and infectious diseases. Although drinking water is a basic human right, many people do not have access to safe and adequate drinking water or proper sanitation facilities. The authors conducted a study to assess the quantity, cost, continuity, coverage, and quality of drinking water in the village of Zawtar El-Charkieh, Lebanon. Their aim was to identify the challenges of sustainable access to safe drinking water in order to determine the short-term management actions and long-term strategies to improve water quality. Results revealed that contamination of the source, absence of any disinfection method or insufficient dose, poor maintenance operations, and aging of the networks are significant factors contributing to water contamination during the storage and distribution process. Establishing a comprehensive drinking water system that integrates water supply, quality, and management as well as associated educational programs in order to ensure the safety and sustainability of drinking water supplies is essential.

  15. The reusable launch vehicle technology program

    NASA Astrophysics Data System (ADS)

    Cook, S.

    Today's launch systems have major shortcomings that will increase in significance in the future, and thus are principal drivers for seeking major improvements in space transportation. They are too costly; insufficiently reliable, safe, and operable; and increasingly losing market share to international competition. For the United States to continue its leadership in the human exploration and wide ranging utilization of space, the first order of business must be to achieve low cost, reliable transportatin to Earth orbit. NASA's Access to Space Study, in 1993, recommended the development of a fully reusable single-stage-to-orbit (SSTO) rocket vehicle as an Agency goal. The goal of the Reusable Launch Vehicle (RLV) technology program is to mature the technologies essential for a next-generation reusable launch system capable of reliably serving National space transportation needs at substantially reduced costs. The primary objectives of the RLV technology program are to (1) mature the technologies required for the next-generation system, (2) demonstrate the capability to achieve low development and operational cost, and rapid launch turnaround times and (3) reduce business and technical risks to encourage significant private investment in the commercial development and operation of the next-generation system. Developing and demonstrating the technologies required for a Single Stage to Orbit (SSTO) rocket is a focus of the program becuase past studies indicate that it has the best potential for achieving the lowest space access cost while acting as an RLV technology driver (since it also encompasses the technology requirements of reusable rocket vehicles in general).

  16. The reusable launch vehicle technology program

    NASA Technical Reports Server (NTRS)

    Cook, S.

    1995-01-01

    Today's launch systems have major shortcomings that will increase in significance in the future, and thus are principal drivers for seeking major improvements in space transportation. They are too costly; insufficiently reliable, safe, and operable; and increasingly losing market share to international competition. For the United States to continue its leadership in the human exploration and wide ranging utilization of space, the first order of business must be to achieve low cost, reliable transportatin to Earth orbit. NASA's Access to Space Study, in 1993, recommended the development of a fully reusable single-stage-to-orbit (SSTO) rocket vehicle as an Agency goal. The goal of the Reusable Launch Vehicle (RLV) technology program is to mature the technologies essential for a next-generation reusable launch system capable of reliably serving National space transportation needs at substantially reduced costs. The primary objectives of the RLV technology program are to (1) mature the technologies required for the next-generation system, (2) demonstrate the capability to achieve low development and operational cost, and rapid launch turnaround times and (3) reduce business and technical risks to encourage significant private investment in the commercial development and operation of the next-generation system. Developing and demonstrating the technologies required for a Single Stage to Orbit (SSTO) rocket is a focus of the program becuase past studies indicate that it has the best potential for achieving the lowest space access cost while acting as an RLV technology driver (since it also encompasses the technology requirements of reusable rocket vehicles in general).

  17. Exploring parameter effects on the economic outcomes of groundwater-based developments in remote, low-resource settings

    NASA Astrophysics Data System (ADS)

    Abramson, Adam; Adar, Eilon; Lazarovitch, Naftali

    2014-06-01

    Groundwater is often the most or only feasible safe drinking water source in remote, low-resource areas, yet the economics of its development have not been systematically outlined. We applied AWARE (Assessing Water Alternatives in Remote Economies), a recently developed Decision Support System, to investigate the costs and benefits of groundwater access and abstraction for non-networked, rural supplies. Synthetic profiles of community water services (n = 17,962), defined across 13 parameters' values and ranges relevant to remote areas, were applied to the decision framework, and the parameter effects on economic outcomes were investigated. Regressions and analysis of output distributions indicate that the most important factors determining the cost of water improvements include the technological approach, the water service target, hydrological parameters, and population density. New source construction is less cost-effective than the use or improvement of existing wells, but necessary for expanding access to isolated households. We also explored three financing approaches - willingness-to-pay, -borrow, and -work - and found that they significantly impact the prospects of achieving demand-driven cost recovery. The net benefit under willingness to work, in which water infrastructure is coupled to community irrigation and cash payments replaced by labor commitments, is impacted most strongly by groundwater yield and managerial factors. These findings suggest that the cost-benefit dynamics of groundwater-based water supply improvements vary considerably by many parameters, and that the relative strengths of different development strategies may be leveraged for achieving optimal outcomes.

  18. Can low-cost motion-tracking systems substitute a Polhemus system when researching social motor coordination in children?

    PubMed

    Romero, Veronica; Amaral, Joseph; Fitzpatrick, Paula; Schmidt, R C; Duncan, Amie W; Richardson, Michael J

    2017-04-01

    Functionally stable and robust interpersonal motor coordination has been found to play an integral role in the effectiveness of social interactions. However, the motion-tracking equipment required to record and objectively measure the dynamic limb and body movements during social interaction has been very costly, cumbersome, and impractical within a non-clinical or non-laboratory setting. Here we examined whether three low-cost motion-tracking options (Microsoft Kinect skeletal tracking of either one limb or whole body and a video-based pixel change method) can be employed to investigate social motor coordination. Of particular interest was the degree to which these low-cost methods of motion tracking could be used to capture and index the coordination dynamics that occurred between a child and an experimenter for three simple social motor coordination tasks in comparison to a more expensive, laboratory-grade motion-tracking system (i.e., a Polhemus Latus system). Overall, the results demonstrated that these low-cost systems cannot substitute the Polhemus system in some tasks. However, the lower-cost Microsoft Kinect skeletal tracking and video pixel change methods were successfully able to index differences in social motor coordination in tasks that involved larger-scale, naturalistic whole body movements, which can be cumbersome and expensive to record with a Polhemus. However, we found the Kinect to be particularly vulnerable to occlusion and the pixel change method to movements that cross the video frame midline. Therefore, particular care needs to be taken in choosing the motion-tracking system that is best suited for the particular research.

  19. Prevention, screening and treatment of colorectal cancer: a global and regional generalized cost effectiveness analysis

    PubMed Central

    2010-01-01

    Background Regional generalized cost-effectiveness estimates of prevention, screening and treatment interventions for colorectal cancer are presented. Methods Standardised WHO-CHOICE methodology was used. A colorectal cancer model was employed to provide estimates of screening and treatment effectiveness. Intervention effectiveness was determined via a population state-transition model (PopMod) that simulates the evolution of a sub-regional population accounting for births, deaths and disease epidemiology. Economic costs of procedures and treatment were estimated, including programme overhead and training costs. Results In regions characterised by high income, low mortality and high existing treatment coverage, the addition of screening to the current high treatment levels is very cost-effective, although no particular intervention stands out in cost-effectiveness terms relative to the others. In regions characterised by low income, low mortality with existing treatment coverage around 50%, expanding treatment with or without screening is cost-effective or very cost-effective. Abandoning treatment in favour of screening (no treatment scenario) would not be cost effective. In regions characterised by low income, high mortality and low treatment levels, the most cost-effective intervention is expanding treatment. Conclusions From a cost-effectiveness standpoint, screening programmes should be expanded in developed regions and treatment programmes should be established for colorectal cancer in regions with low treatment coverage. PMID:20236531

  20. An aqueous, polymer-based redox-flow battery using non-corrosive, safe, and low-cost materials.

    PubMed

    Janoschka, Tobias; Martin, Norbert; Martin, Udo; Friebe, Christian; Morgenstern, Sabine; Hiller, Hannes; Hager, Martin D; Schubert, Ulrich S

    2015-11-05

    For renewable energy sources such as solar, wind, and hydroelectric to be effectively used in the grid of the future, flexible and scalable energy-storage solutions are necessary to mitigate output fluctuations. Redox-flow batteries (RFBs) were first built in the 1940s and are considered a promising large-scale energy-storage technology. A limited number of redox-active materials--mainly metal salts, corrosive halogens, and low-molar-mass organic compounds--have been investigated as active materials, and only a few membrane materials, such as Nafion, have been considered for RFBs. However, for systems that are intended for both domestic and large-scale use, safety and cost must be taken into account as well as energy density and capacity, particularly regarding long-term access to metal resources, which places limits on the lithium-ion-based and vanadium-based RFB development. Here we describe an affordable, safe, and scalable battery system, which uses organic polymers as the charge-storage material in combination with inexpensive dialysis membranes, which separate the anode and the cathode by the retention of the non-metallic, active (macro-molecular) species, and an aqueous sodium chloride solution as the electrolyte. This water- and polymer-based RFB has an energy density of 10 watt hours per litre, current densities of up to 100 milliamperes per square centimetre, and stable long-term cycling capability. The polymer-based RFB we present uses an environmentally benign sodium chloride solution and cheap, commercially available filter membranes instead of highly corrosive acid electrolytes and expensive membrane materials.

  1. An aqueous, polymer-based redox-flow battery using non-corrosive, safe, and low-cost materials

    NASA Astrophysics Data System (ADS)

    Janoschka, Tobias; Martin, Norbert; Martin, Udo; Friebe, Christian; Morgenstern, Sabine; Hiller, Hannes; Hager, Martin D.; Schubert, Ulrich S.

    2015-11-01

    For renewable energy sources such as solar, wind, and hydroelectric to be effectively used in the grid of the future, flexible and scalable energy-storage solutions are necessary to mitigate output fluctuations. Redox-flow batteries (RFBs) were first built in the 1940s and are considered a promising large-scale energy-storage technology. A limited number of redox-active materials--mainly metal salts, corrosive halogens, and low-molar-mass organic compounds--have been investigated as active materials, and only a few membrane materials, such as Nafion, have been considered for RFBs. However, for systems that are intended for both domestic and large-scale use, safety and cost must be taken into account as well as energy density and capacity, particularly regarding long-term access to metal resources, which places limits on the lithium-ion-based and vanadium-based RFB development. Here we describe an affordable, safe, and scalable battery system, which uses organic polymers as the charge-storage material in combination with inexpensive dialysis membranes, which separate the anode and the cathode by the retention of the non-metallic, active (macro-molecular) species, and an aqueous sodium chloride solution as the electrolyte. This water- and polymer-based RFB has an energy density of 10 watt hours per litre, current densities of up to 100 milliamperes per square centimetre, and stable long-term cycling capability. The polymer-based RFB we present uses an environmentally benign sodium chloride solution and cheap, commercially available filter membranes instead of highly corrosive acid electrolytes and expensive membrane materials.

  2. Residential tornado safe room from commodity wood products – design and development

    Treesearch

    Robert H. Falk; James J. Bridwell

    2018-01-01

    In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms have helped decrease the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a nonproprietary residential tornado safe...

  3. Safely Intake Number of Macridiscus sp. (Kerang Ceplos) from Tambak Lorok Waters, Semarang, Central Java, Indonesia

    NASA Astrophysics Data System (ADS)

    Meirenno Tielman, Eduard; Suprijanto, Jusup; Widowati, Ita

    2018-02-01

    The dynamics pollution that supposed to be derived from industrial activities around Tambak Lorok waters will affect the quality of waters, and also biota such as Macridiscus sp. mussels (Kerang Ceplos) that live and accumulate pollutants such as heavy metals (Pb, Cu, Al, Mn and Fe). However, Macridiscus sp. mussels which have been contaminated by heavy metals is usually sold for consumption by the people and if they consume it in excess, it will be toxic in the people’s body. So that, this study was to analyze Safely Intake Number of Macridiscus sp. from Tambak Lorok waters. This study used AAS (Atomic Absorption Spectrophotometry) method to analyze the accumulation number of the pollutant (Pb, Cu, Al, Mn and Fe). Safely Intake Number calculation is used MWI (Maximal Weekly Intake) and MTI (Maximal Tolerable Intake) calculation method. The results of AAS showed that the highest numbers of pollutant was Al (reached 534,51 mg/kg in the body of Macridiscus sp. that taken in February, 2016) and has exceeded the safely intake number (MWI Al = 1 mg/kg, based on WHO/FAO) so that it’s MTI values was low (0,08 kg/week/person). It means that Macridiscus sp. was not safe to be consumed excessively at that time.

  4. Design, processing and testing of LSI arrays: Hybrid microelectronics task

    NASA Technical Reports Server (NTRS)

    Himmel, R. P.; Stuhlbarg, S. M.; Ravetti, R. G.; Zulueta, P. J.

    1979-01-01

    Mathematical cost factors were generated for both hybrid microcircuit and printed wiring board packaging methods. A mathematical cost model was created for analysis of microcircuit fabrication costs. The costing factors were refined and reduced to formulae for computerization. Efficient methods were investigated for low cost packaging of LSI devices as a function of density and reliability. Technical problem areas such as wafer bumping, inner/outer leading bonding, testing on tape, and tape processing, were investigated.

  5. Apollo - An advanced fuel fusion power reactor for the 21st century

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulcinski, G.L.; Emmert, G.A.; Blanchard, J.P.

    1989-03-01

    A preconceptual design of a tokamak reactor fueled by a D-He-3 plasma is presented. A low aspect ratio (A=2-4) device is studied here but high aspect ratio devices (A > 6) may also be quite attractive. The Apollo D-He-3 tokamak capitalizes on recent advances in high field magnets (20 T) and utilizes rectennas to convert the synchrotron radiation directly to electricity. The overall efficiency ranges from 37 to 52% depending on whether the bremsstrahlung energy is utilized. The low neutron wall loading (0.1 MW/m/sup 2/) allows a permanent first wall to be designed and the low nuclear decay heat enablesmore » the reactor to be classed as inherently safe. The cost of electricity from Apollo is > 40% lower than electricity from a similar sized DT reactor.« less

  6. Development of a wireless displacement measurement system using acceleration responses.

    PubMed

    Park, Jong-Woong; Sim, Sung-Han; Jung, Hyung-Jo; Spencer, Billie F

    2013-07-01

    Displacement measurements are useful information for various engineering applications such as structural health monitoring (SHM), earthquake engineering and system identification. Most existing displacement measurement methods are costly, labor-intensive, and have difficulties particularly when applying to full-scale civil structures because the methods require stationary reference points. Indirect estimation methods converting acceleration to displacement can be a good alternative as acceleration transducers are generally cost-effective, easy to install, and have low noise. However, the application of acceleration-based methods to full-scale civil structures such as long span bridges is challenging due to the need to install cables to connect the sensors to a base station. This article proposes a low-cost wireless displacement measurement system using acceleration. Developed with smart sensors that are low-cost, wireless, and capable of on-board computation, the wireless displacement measurement system has significant potential to impact many applications that need displacement information at multiple locations of a structure. The system implements an FIR-filter type displacement estimation algorithm that can remove low frequency drifts typically caused by numerical integration of discrete acceleration signals. To verify the accuracy and feasibility of the proposed system, laboratory tests are carried out using a shaking table and on a three storey shear building model, experimentally confirming the effectiveness of the proposed system.

  7. Development of a Wireless Displacement Measurement System Using Acceleration Responses

    PubMed Central

    Park, Jong-Woong; Sim, Sung-Han; Jung, Hyung-Jo; Spencer, Billie F.

    2013-01-01

    Displacement measurements are useful information for various engineering applications such as structural health monitoring (SHM), earthquake engineering and system identification. Most existing displacement measurement methods are costly, labor-intensive, and have difficulties particularly when applying to full-scale civil structures because the methods require stationary reference points. Indirect estimation methods converting acceleration to displacement can be a good alternative as acceleration transducers are generally cost-effective, easy to install, and have low noise. However, the application of acceleration-based methods to full-scale civil structures such as long span bridges is challenging due to the need to install cables to connect the sensors to a base station. This article proposes a low-cost wireless displacement measurement system using acceleration. Developed with smart sensors that are low-cost, wireless, and capable of on-board computation, the wireless displacement measurement system has significant potential to impact many applications that need displacement information at multiple locations of a structure. The system implements an FIR-filter type displacement estimation algorithm that can remove low frequency drifts typically caused by numerical integration of discrete acceleration signals. To verify the accuracy and feasibility of the proposed system, laboratory tests are carried out using a shaking table and on a three storey shear building model, experimentally confirming the effectiveness of the proposed system. PMID:23881123

  8. Integration of Family Planning Services into HIV Care and Treatment Services: A Systematic Review.

    PubMed

    Haberlen, Sabina A; Narasimhan, Manjulaa; Beres, Laura K; Kennedy, Caitlin E

    2017-06-01

    Evidence on the feasibility, effectiveness, and cost-effectiveness of integrating family planning (FP) and HIV services has grown significantly since the 2004 Glion Call to Action. This systematic review adds to the knowledge base by characterizing the range of models used to integrate FP into HIV care and treatment, and synthesizing the evidence on integration outcomes among women living with HIV. Fourteen studies met our inclusion criteria, eight of which were published after the last systematic review on the topic in 2013. Overall, integration was associated with higher modern method contraceptive prevalence and knowledge, although there was insufficient evidence to evaluate its effects on unintended pregnancy or achieving safe and healthy pregnancy. Evidence for change in unmet need for FP was limited, although two of the three evaluations that measured unmet need suggested possible improvements associated with integrated services. However, improving access to FP services through integration was not always sufficient to increase the use of more effective (noncondom) modern methods among women who wanted to prevent pregnancy. Integration efforts, particularly in contexts where contraceptive use is low, must address community-wide and HIV-specific barriers to using effective FP methods alongside improving access to information, commodities, and services within routine HIV care. © 2017 The Population Council, Inc.

  9. Evaluation of a Fast and Simple Sample Preparation Method for Polybrominated Diphenyl Ether (PBDE) Flame Retardants and Dichlorodiphenyltrichloroethane (DDT) Pesticides in Fish for Analysis by ELISA Compared with GC-MS/MS.

    PubMed

    Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J

    2015-05-13

    A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.

  10. Design Methods and Practices for Fault Prevention and Management in Spacecraft

    NASA Technical Reports Server (NTRS)

    Tumer, Irem Y.

    2005-01-01

    Integrated Systems Health Management (ISHM) is intended to become a critical capability for all space, lunar and planetary exploration vehicles and systems at NASA. Monitoring and managing the health state of diverse components, subsystems, and systems is a difficult task that will become more challenging when implemented for long-term, evolving deployments. A key technical challenge will be to ensure that the ISHM technologies are reliable, effective, and low cost, resulting in turn in safe, reliable, and affordable missions. To ensure safety and reliability, ISHM functionality, decisions and knowledge have to be incorporated into the product lifecycle as early as possible, and ISHM must be considered as an essential element of models developed and used in various stages during system design. During early stage design, many decisions and tasks are still open, including sensor and measurement point selection, modeling and model-checking, diagnosis, signature and data fusion schemes, presenting the best opportunity to catch and prevent potential failures and anomalies in a cost-effective way. Using appropriate formal methods during early design, the design teams can systematically explore risks without committing to design decisions too early. However, the nature of ISHM knowledge and data is detailed, relying on high-fidelity, detailed models, whereas the earlier stages of the product lifecycle utilize low-fidelity, high-level models of systems and their functionality. We currently lack the tools and processes necessary for integrating ISHM into the vehicle system/subsystem design. As a result, most existing ISHM-like technologies are retrofits that were done after the system design was completed. It is very expensive, and sometimes futile, to retrofit a system health management capability into existing systems. Last-minute retrofits result in unreliable systems, ineffective solutions, and excessive costs (e.g., Space Shuttle TPS monitoring which was considered only after 110 flights and the Columbia disaster). High false alarm or false negative rates due to substandard implementations hurt the credibility of the ISHM discipline. This paper presents an overview of the current state of ISHM design,and a review of formal design methods to make recommendations about possible approaches to enable the ISHM capabilities to be designed-in at the system-level, from the very beginning of the vehicle design process.

  11. Key issues for low-cost FGD installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DePriest, W.; Mazurek, J.M.

    1995-12-01

    This paper will discuss various methods for installing low-cost FGD systems. The paper will include a discussion of various types of FGD systems available, both wet and dry, and will compare the relative cost of each type. Important design issues, such as use of spare equipment, materials of construction, etc. will be presented. An overview of various low-cost construction techniques (i.e., modularization) will be included. This paper will draw heavily from Sargent & Lundy`s database of past and current FGD projects together with information we gathered for several Electric Power Research Institute (EPRI) studies on the subject.

  12. A LEO Satellite Navigation Algorithm Based on GPS and Magnetometer Data

    NASA Technical Reports Server (NTRS)

    Deutschmann, Julie; Bar-Itzhack, Itzhack; Harman, Rick; Bauer, Frank H. (Technical Monitor)

    2000-01-01

    The Global Positioning System (GPS) has become a standard method for low cost onboard satellite orbit determination. The use of a GPS receiver as an attitude and rate sensor has also been developed in the recent past. Additionally, focus has been given to attitude and orbit estimation using the magnetometer, a low cost, reliable sensor. Combining measurements from both GPS and a magnetometer can provide a robust navigation system that takes advantage of the estimation qualities of both measurements. Ultimately a low cost, accurate navigation system can result, potentially eliminating the need for more costly sensors, including gyroscopes.

  13. The cost-effectiveness of influenza vaccination of healthy adults 50-64 years of age.

    PubMed

    Turner, D A; Wailoo, A J; Cooper, N J; Sutton, A J; Abrams, K R; Nicholson, K G

    2006-02-13

    Influenza can cause significant morbidity and mortality. Influenza vaccination is an effective and safe strategy in the prevention of influenza. Currently the National Health Service (NHS) vaccinates 'at-risk' individuals only. This definition includes everyone over 65 years of age but excludes individuals 50-64 years of age unless they have an additional risk factor, such as underlying heart disease or lung disease. In order to examine the cost-effectiveness of an extension of the vaccination policy to include this age group we constructed an economic model to estimate the costs and benefits of vaccination from both a health service and a societal perspective. Data to populate the model was obtained from the literature and the outcome measure used was the quality adjusted life year (QALY). Influenza vaccination prevented an estimated 4508 cases (95% CI: 2431-7606) per 100,000 vaccinees per influenza season for a net cost to the NHS of pound653,221 (95% CI: 354,575-1,072,257). The net cost increased to pound1,139,069 (95% CI 27,052-2,030,473) when non-NHS costs were included and the estimated cost-per-QALY were pound6174 and pound10,766 for NHS and all costs respectively. Extension of the current immunisation policy has the potential to generate a significant health benefit at a comparatively low cost.

  14. NASA Tech Briefs, June 2014

    NASA Technical Reports Server (NTRS)

    2014-01-01

    Topics include: Real-Time Minimization of Tracking Error for Aircraft Systems; Detecting an Extreme Minority Class in Hyperspectral Data Using Machine Learning; KSC Spaceport Weather Data Archive; Visualizing Acquisition, Processing, and Network Statistics Through Database Queries; Simulating Data Flow via Multiple Secure Connections; Systems and Services for Near-Real-Time Web Access to NPP Data; CCSDS Telemetry Decoder VHDL Core; Thermal Response of a High-Power Switch to Short Pulses; Solar Panel and System Design to Reduce Heating and Optimize Corridors for Lower-Risk Planetary Aerobraking; Low-Cost, Very Large Diamond-Turned Metal Mirror; Very-High-Load-Capacity Air Bearing Spindle for Large Diamond Turning Machines; Elevated-Temperature, Highly Emissive Coating for Energy Dissipation of Large Surfaces; Catalyst for Treatment and Control of Post-Combustion Emissions; Thermally Activated Crack Healing Mechanism for Metallic Materials; Subsurface Imaging of Nanocomposites; Self-Healing Glass Sealants for Solid Oxide Fuel Cells and Electrolyzer Cells; Micromachined Thermopile Arrays with Novel Thermo - electric Materials; Low-Cost, High-Performance MMOD Shielding; Head-Mounted Display Latency Measurement Rig; Workspace-Safe Operation of a Force- or Impedance-Controlled Robot; Cryogenic Mixing Pump with No Moving Parts; Seal Design Feature for Redundancy Verification; Dexterous Humanoid Robot; Tethered Vehicle Control and Tracking System; Lunar Organic Waste Reformer; Digital Laser Frequency Stabilization via Cavity Locking Employing Low-Frequency Direct Modulation; Deep UV Discharge Lamps in Capillary Quartz Tubes with Light Output Coupled to an Optical Fiber; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems, Version II; Advanced Sensor Technology for Algal Biotechnology; High-Speed Spectral Mapper; "Ascent - Commemorating Shuttle" - A NASA Film and Multimedia Project DVD; High-Pressure, Reduced-Kinetics Mechanism for N-Hexadecane Oxidation; Method of Error Floor Mitigation in Low-Density Parity-Check Codes; X-Ray Flaw Size Parameter for POD Studies; Large Eddy Simulation Composition Equations for Two-Phase Fully Multicomponent Turbulent Flows; Scheduling Targeted and Mapping Observations with State, Resource, and Timing Constraints;

  15. Business model innovation in the water sector in developing countries.

    PubMed

    Gebauer, Heiko; Saul, Caroline Jennings

    2014-08-01

    Various technologies have been deployed in household devices or micro-water treatment plants for mitigating fluoride and arsenic, and thereby provide safe and affordable drinking water in low-income countries. While the technologies have improved considerably, organizations still face challenges in making them financially sustainable. Financial sustainability questions the business models behind these water technologies. This article makes three contributions to business models in the context of fluoride and arsenic mitigation. Firstly, we describe four business models: A) low-value devices given away to people living in extreme poverty, B) high-value devices sold to low-income customers, C) communities as beneficiaries of micro-water treatment plants and D) entrepreneurs as franchisees for selling water services and highlight the emergence of hybrid business models. Secondly, we show current business model innovations such as cost transparency & cost reductions, secured & extended water payments, business diversification and distribution channels. Thirdly, we describe skills and competencies as part of capacity building for creating even more business model innovations. Together, these three contributions will create more awareness of the role of business models in scaling-up water treatment technologies. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Aileron controls for wind turbine applications

    NASA Technical Reports Server (NTRS)

    Miller, D. R.; Putoff, R. L.

    1984-01-01

    Horizontal axis wind turbines which utilize partial or full variable blade pitch to regulate rotor speed were examined. The weight and costs of these systems indicated a need for alternate methods of rotor control. Aileron control is an alternative which has potential to meet this need. Aileron control rotors were tested on the Mod-O wind turbine to determine their power regulation and shutdown characteristics. Test results for a 20 and 38% chord aileron control rotor are presented. Test is shown that aileron control is a viable method for safety for safely controlling rotor speed, following a loss of general load.

  17. Aileron controls for wind turbine applications

    NASA Technical Reports Server (NTRS)

    Miller, D. R.; Puthoff, R. L.

    1984-01-01

    Horizontal axis wind turbines which utilize partial or full variable blade pitch to regulate rotor speed were examined. The weight and costs of these systems indicated a need for alternate methods of rotor control. Aileron control is an alternative which has potential to meet this need. Aileron control rotors were tested on the Mod-O wind turbine to determine their power regulation and shutdown characteristics. Test results for a 20 and 38 percent chord aileron control rotor are presented. Test is shown that aileron control is a viable method for safety for safely controlling rotor speed, following a loss of general load.

  18. Absolute calibration of the Jenoptik CHM15k-x ceilometer and its applicability for quantitative aerosol monitoring

    NASA Astrophysics Data System (ADS)

    Geiß, Alexander; Wiegner, Matthias

    2014-05-01

    The knowledge of the spatiotemporal distribution of atmospheric aerosols and its optical characterization is essential for the understanding of the radiation budget, air quality, and climate. For this purpose, lidar is an excellent system as it is an active remote sensing technique. As multi-wavelength research lidars with depolarization channels are quite complex and cost-expensive, increasing attention is paid to so-called ceilometers. They are simple one-wavelength backscatter lidars with low pulse energy for eye-safe operation. As maintenance costs are low and continuous and unattended measurements can be performed, they are suitable for long-term aerosol monitoring in a network. However, the signal-to-noise ratio is low, and the signals are not calibrated. The only optical property that can be derived from a ceilometer is the particle backscatter coefficient, but even this quantity requires a calibration of the signals. With four years of measurements from a Jenoptik ceilometer CHM15k-x, we developed two methods for an absolute calibration on this system. This advantage of our approach is that only a few days with favorable meteorological conditions are required where Rayleigh-calibration and comparison with our research lidar is possible to estimate the lidar constant. This method enables us to derive the particle backscatter coefficient at 1064 nm, and we retrieved for the first time profiles in near real-time within an accuracy of 10 %. If an appropriate lidar ratio is assumed the aerosol optical depth of e.g. the mixing layer can be determined with an accuracy depending on the accuracy of the lidar ratio estimate. Even for 'simple' applications, e.g. assessment of the mixing layer height, cloud detection, detection of elevated aerosol layers, the particle backscatter coefficient has significant advantages over the measured (uncalibrated) attenuated backscatter. The possibility of continuous operation under nearly any meteorological condition with temporal resolution in the order of 30 seconds makes it also possible to apply time-height-tracking methods for detecting mixing layer heights. The combination of methods for edge detection (e.g. wavelet covariance transform, gradient method, variance method) and edge tracking techniques is used to increase the reliability of the layer detection and attribution. Thus, a feature mask of aerosols and clouds can be derived. Four years of measurements constitute an excellent basis for a climatology including a homogeneous time series of mixing layer heights, aerosol layers and cloud base heights of the troposphere. With a low overlap region of 180 m of the Jenoptik CHM15k-x even very narrow mixing layers, typical for winter conditions, can be considered.

  19. Reliability model for ductile hybrid FRP rebar using randomly dispersed chopped fibers

    NASA Astrophysics Data System (ADS)

    Behnam, Bashar Ramzi

    Fiber reinforced polymer composites or simply FRP composites have become more attractive to civil engineers in the last two decades due to their unique mechanical properties. However, there are many obstacles such as low elasticity modulus, non-ductile behavior, high cost of the fibers, high manufacturing costs, and absence of rigorous characterization of the uncertainties of the mechanical properties that restrict the use of these composites. However, when FRP composites are used to develop reinforcing rebars in concrete structural members to replace the conventional steel, a huge benefit can be achieved since FRP materials don't corrode. Two FRP rebar models are proposed that make use of multiple types of fibers to achieve ductility, and chopped fibers are used to reduce the manufacturing costs. In order to reach the most optimum fractional volume of each type of fiber, to minimize the cost of the proposed rebars, and to achieve a safe design by considering uncertainties in the materials and geometry of sections, appropriate material resistance factors have been developed, and a Reliability Based Design Optimization (RBDO), has been conducted for the proposed schemes.

  20. An innovative national health care waste management system in Kyrgyzstan.

    PubMed

    Toktobaev, Nurjan; Emmanuel, Jorge; Djumalieva, Gulmira; Kravtsov, Alexei; Schüth, Tobias

    2015-02-01

    A novel low-cost health care waste management system was implemented in all rural hospitals in Kyrgyzstan. The components of the Kyrgyz model include mechanical needle removers, segregation using autoclavable containers, safe transport and storage, autoclave treatment, documentation, recycling of sterilized plastic and metal parts, cement pits for anatomical waste, composting of garden wastes, training, equipment maintenance, and management by safety and quality committees. The gravity-displacement autoclaves were fitted with filters to remove pathogens from the air exhaust. Operating parameters for the autoclaves were determined by thermal and biological tests. A hospital survey showed an average 33% annual cost savings compared to previous costs for waste management. All general hospitals with >25 beds except in the capital Bishkek use the new system, corresponding to 67.3% of all hospital beds. The investment amounted to US$0.61 per capita covered. Acceptance of the new system by the staff, cost savings, revenues from recycled materials, documented improvements in occupational safety, capacity building, and institutionalization enhance the sustainability of the Kyrgyz health care waste management system. © The Author(s) 2015.

  1. Decontamination of Anthrax spores in critical infrastructure and critical assets.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boucher, Raymond M.; Crown, Kevin K.; Tucker, Mark David

    2010-05-01

    Decontamination of anthrax spores in critical infrastructure (e.g., subway systems, major airports) and critical assets (e.g., the interior of aircraft) can be challenging because effective decontaminants can damage materials. Current decontamination methods require the use of highly toxic and/or highly corrosive chemical solutions because bacterial spores are very difficult to kill. Bacterial spores such as Bacillus anthracis, the infectious agent of anthrax, are one of the most resistant forms of life and are several orders of magnitude more difficult to kill than their associated vegetative cells. Remediation of facilities and other spaces (e.g., subways, airports, and the interior of aircraft)more » contaminated with anthrax spores currently requires highly toxic and corrosive chemicals such as chlorine dioxide gas, vapor- phase hydrogen peroxide, or high-strength bleach, typically requiring complex deployment methods. We have developed a non-toxic, non-corrosive decontamination method to kill highly resistant bacterial spores in critical infrastructure and critical assets. A chemical solution that triggers the germination process in bacterial spores and causes those spores to rapidly and completely change to much less-resistant vegetative cells that can be easily killed. Vegetative cells are then exposed to mild chemicals (e.g., low concentrations of hydrogen peroxide, quaternary ammonium compounds, alcohols, aldehydes, etc.) or natural elements (e.g., heat, humidity, ultraviolet light, etc.) for complete and rapid kill. Our process employs a novel germination solution consisting of low-cost, non-toxic and non-corrosive chemicals. We are testing both direct surface application and aerosol delivery of the solutions. A key Homeland Security need is to develop the capability to rapidly recover from an attack utilizing biological warfare agents. This project will provide the capability to rapidly and safely decontaminate critical facilities and assets to return them to normal operations as quickly as possible, sparing significant economic damage by re-opening critical facilities more rapidly and safely. Facilities and assets contaminated with Bacillus anthracis (i.e., anthrax) spores can be decontaminated with mild chemicals as compared to the harsh chemicals currently needed. Both the 'germination' solution and the 'kill' solution are constructed of 'off-the-shelf,' inexpensive chemicals. The method can be utilized by directly spraying the solutions onto exposed surfaces or by application of the solutions as aerosols (i.e., small droplets), which can also reach hidden surfaces.« less

  2. Nutrition support teams: how they work, are set up and maintained

    PubMed Central

    Nightingale, Jeremy

    2010-01-01

    Safe cost effective nutritional support is provided by a multidisciplinary team whose activity is overseen by a Nutrition Steering Group that reports directly to the Hospital Trust Board. When a nutrition support team (NST) is first formed, a nutrition nurse specialist enables parenteral nutrition to be given safely. An NST needs to have a clearly agreed scope of practice and needs to be able to justify its presence in terms of quality and cost savings. PMID:28839571

  3. Design and evaluation of low-cost stainless steel fiberglass foam blades for large wind driven generating systems

    NASA Technical Reports Server (NTRS)

    Eggert, W. S.

    1982-01-01

    A low cost wind turbine blade based on a stainless steel fiberglass foam Budd blade design concept, was evaluated for its principle characteristics, low cost features, and its advantages and disadvantages. A blade structure was designed and construction methods and materials were selected. A complete blade tooling concepts, various technical and economic analysis, and evaluations of the blade design were performed. A comprehensive fatigue test program is conducted to provide data to verify the design stress allowables.

  4. Design and evaluation of low-cost stainless steel fiberglass foam blades for large wind driven generating systems

    NASA Astrophysics Data System (ADS)

    Eggert, W. S.

    1982-10-01

    A low cost wind turbine blade based on a stainless steel fiberglass foam Budd blade design concept, was evaluated for its principle characteristics, low cost features, and its advantages and disadvantages. A blade structure was designed and construction methods and materials were selected. A complete blade tooling concepts, various technical and economic analysis, and evaluations of the blade design were performed. A comprehensive fatigue test program is conducted to provide data to verify the design stress allowables.

  5. Modeling the Impact of Uganda's Safe Male Circumcision Program: Implications for Age and Regional Targeting.

    PubMed

    Kripke, Katharine; Vazzano, Andrea; Kirungi, William; Musinguzi, Joshua; Opio, Alex; Ssempebwa, Rhobbinah; Nakawunde, Susan; Kyobutungi, Sheila; Akao, Juliet N; Magala, Fred; Mwidu, George; Castor, Delivette; Njeuhmeli, Emmanuel

    2016-01-01

    Uganda aims to provide safe male circumcision (SMC) to 80% of men ages 15-49 by 2016. To date, only 2 million men have received SMC of the 4.2 million men required. In response to age and regional trends in SMC uptake, the country sought to re-examine its targets with respect to age and subnational region, to assess the program's progress, and to refine the implementation approach. The Decision Makers' Program Planning Tool, Version 2.0 (DMPPT 2.0), was used in conjunction with incidence projections from the Spectrum/AIDS Impact Module (AIM) to conduct this analysis. Population, births, deaths, and HIV incidence and prevalence were used to populate the model. Baseline male circumcision prevalence was derived from the 2011 AIDS Indicator Survey. Uganda can achieve the most immediate impact on HIV incidence by circumcising men ages 20-34. This group will also require the fewest circumcisions for each HIV infection averted. Focusing on men ages 10-19 will offer the greatest impact over a 15-year period, while focusing on men ages 15-34 offers the most cost-effective strategy over the same period. A regional analysis showed little variation in cost-effectiveness of scaling up SMC across eight regions. Scale-up is cost-saving in all regions. There is geographic variability in program progress, highlighting two regions with low baseline rates of circumcision where additional efforts will be needed. Focusing SMC efforts on specific age groups and regions may help to accelerate Uganda's SMC program progress. Policy makers in Uganda have already used model outputs in planning efforts, proposing males ages 10-34 as a priority group for SMC in the 2014 application to the Global Fund's new funding model. As scale-up continues, the country should also consider a greater effort to expand SMC in regions with low MC prevalence.

  6. Substantiation of artificial composite-structure roof construction in top-down cut-and-fill stoping

    NASA Astrophysics Data System (ADS)

    Rukavishnikov, GD; Neverov, SA; Neverov, AA

    2018-03-01

    It has been found efficient and safe to use top-down cut-and-fill stoping with saving of the artificial backfill cost and material through the use of a solid nonuniform material composed of two components (layers). It is shown that the artificial roof can be advanced after a stope without essential change in the stope condition as compared with the classical top-down slice method, which provides higher safety of mining.

  7. Research on the Application of Risk-based Inspection for the Boiler System in Power Plant

    NASA Astrophysics Data System (ADS)

    Li, Henan

    2017-12-01

    Power plant boiler is one of the three main equipment of coal-fired power plants, is very tall to the requirement of the safe and stable operation, in a significant role in the whole system of thermal power generation, a risk-based inspection is a kind of pursuit of security and economy of unified system management idea and method, can effectively evaluate equipment risk and reduce the operational cost.

  8. A program needs-driven approach to selecting dietary assessment methods for decision-making in food fortification programs.

    PubMed

    Coates, Jennifer; Colaiezzi, Brooke; Fiedler, John L; Wirth, James; Lividini, Keith; Rogers, Beatrice

    2012-09-01

    Dietary assessment data are essential for designing, monitoring, and evaluating food fortification and other food-based nutrition programs. Planners and managers must understand the validity, usefulness, and cost tradeoffs of employing alternative dietary assessment methods, but little guidance exists. To identify and apply criteria to assess the tradeoffs of using alternative dietary methods for meeting fortification programming needs. Twenty-five semistructured expert interviews were conducted and literature was reviewed for information on the validity, usefulness, and cost of using 24-hour recalls, Food Frequency Questionnaires/Fortification Rapid Assessment Tool (FFQ/FRAT), Food Balance Sheets (FBS), and Household Consumption and Expenditures Surveys (HCES) for program stage-specific information needs. Criteria were developed and applied to construct relative rankings of the four methods. Needs assessment: HCES offers the greatest suitability at the lowest cost for estimating the risk of inadequate intakes, but relative to 24-hour recall compromises validity. HCES should be used to identify vehicles and to estimate coverage and likely impact due to its low cost and moderate-to-high validity. Baseline assessment: 24-hour recall should be applied using a representative sample. Monitoring: A simple, low-cost FFQ can be used to monitor coverage. Impact evaluation: 24-hour recall should be used to assess changes in nutrient intakes. FBS have low validity relative to other methods for all programmatic purposes. Each dietary assessment method has strengths and weaknesses that vary by context and purpose. Method selection must be driven by the program's data needs, the suitability of the methods for the purpose, and a clear understanding of the tradeoffs involved.

  9. Closed-system drug-transfer devices plus safe handling of hazardous drugs versus safe handling alone for reducing exposure to infusional hazardous drugs in healthcare staff.

    PubMed

    Gurusamy, Kurinchi Selvan; Best, Lawrence Mj; Tanguay, Cynthia; Lennan, Elaine; Korva, Mika; Bussières, Jean-François

    2018-03-27

    Occupational exposure to hazardous drugs can decrease fertility and result in miscarriages, stillbirths, and cancers in healthcare staff. Several recommended practices aim to reduce this exposure, including protective clothing, gloves, and biological safety cabinets ('safe handling'). There is significant uncertainty as to whether using closed-system drug-transfer devices (CSTD) in addition to safe handling decreases the contamination and risk of staff exposure to infusional hazardous drugs compared to safe handling alone. To assess the effects of closed-system drug-transfer of infusional hazardous drugs plus safe handling versus safe handling alone for reducing staff exposure to infusional hazardous drugs and risk of staff contamination. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, OSH-UPDATE, CINAHL, Science Citation Index Expanded, economic evaluation databases, the World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov to October 2017. We included comparative studies of any study design (irrespective of language, blinding, or publication status) that compared CSTD plus safe handling versus safe handling alone for infusional hazardous drugs. Two review authors independently identified trials and extracted data. We calculated the risk ratio (RR) and mean difference (MD) with 95% confidence intervals (CI) using both fixed-effect and random-effects models. We assessed risk of bias according to the risk of bias in non-randomised studies of interventions (ROBINS-I) tool, used an intracluster correlation coefficient of 0.10, and we assessed the quality of the evidence using GRADE. We included 23 observational cluster studies (358 hospitals) in this review. We did not find any randomised controlled trials or formal economic evaluations. In 21 studies, the people who used the intervention (CSTD plus safe handling) and control (safe handling alone) were pharmacists or pharmacy technicians; in the other two studies, the people who used the intervention and control were nurses, pharmacists, or pharmacy technicians. The CSTD used in the studies were PhaSeal (13 studies), Tevadaptor (1 study), SpikeSwan (1 study), PhaSeal and Tevadaptor (1 study), varied (5 studies), and not stated (2 studies). The studies' descriptions of the control groups were varied. Twenty-one studies provide data on one or more outcomes for this systematic review. All the studies are at serious risk of bias. The quality of evidence is very low for all the outcomes.There is no evidence of differences in the proportion of people with positive urine tests for exposure between the CSTD and control groups for cyclophosphamide alone (RR 0.83, 95% CI 0.46 to 1.52; I² = 12%; 2 studies; 2 hospitals; 20 participants; CSTD: 76.1% versus control: 91.7%); cyclophosphamide or ifosfamide (RR 0.09, 95% CI 0.00 to 2.79; 1 study; 1 hospital; 14 participants; CSTD: 6.4% versus control: 71.4%); and cyclophosphamide, ifosfamide, or gemcitabine (RR not estimable; 1 study; 1 hospital; 36 participants; 0% in both groups).There is no evidence of a difference in the proportion of surface samples contaminated in the pharmacy areas or patient-care areas for any of the drugs except 5-fluorouracil, which was lower in the CSTD group than in the control (RR 0.65, 95% CI 0.43 to 0.97; 3 studies, 106 hospitals, 1008 samples; CSTD: 9% versus control: 13.9%).The amount of cyclophosphamide was lower in pharmacy areas in the CSTD group than in the control group (MD -49.34 pg/cm², 95% CI -84.11 to -14.56, I² = 0%, 7 studies; 282 hospitals, 1793 surface samples). Additionally, one interrupted time-series study (3 hospitals; 342 samples) demonstrated a change in the slope between pre-CSTD and CSTD (3.9439 pg/cm², 95% CI 1.2303 to 6.6576; P = 0.010), but not between CSTD and post-CSTD withdrawal (-1.9331 pg/cm², 95% CI -5.1260 to 1.2598; P = 0.20). There is no evidence of difference in the amount of the other drugs between CSTD and control groups in the pharmacy areas or patient-care areas.None of the studies report on atmospheric contamination, blood tests, or other measures of exposure to infusional hazardous drugs such as urine mutagenicity, chromosomal aberrations, sister chromatid exchanges, or micronuclei induction.None of the studies report short-term health benefits such as reduction in skin rashes, medium-term reproductive health benefits such as fertility and parity, or long-term health benefits related to the development of any type of cancer or adverse events.Five studies (six hospitals) report the potential cost savings through the use of CSTD. The studies used different methods of calculating the costs, and the results were not reported in a format that could be pooled via meta-analysis. There is significant variability between the studies in terms of whether CSTD resulted in cost savings (the point estimates of the average potential cost savings ranged from (2017) USD -642,656 to (2017) USD 221,818). There is currently no evidence to support or refute the routine use of closed-system drug transfer devices in addition to safe handling of infusional hazardous drugs, as there is no evidence of differences in exposure or financial benefits between CSTD plus safe handling versus safe handling alone (very low-quality evidence). None of the studies report health benefits.Well-designed multicentre randomised controlled trials may be feasible depending upon the proportion of people with exposure. The next best study design is interrupted time-series. This design is likely to provide a better estimate than uncontrolled before-after studies or cross-sectional studies. Future studies may involve other alternate ways of reducing exposure in addition to safe handling as one intervention group in a multi-arm parallel design or factorial design trial. Future studies should have designs that decrease the risk of bias and enable measurement of direct health benefits in addition to exposure. Studies using exposure should be tested for a relevant selection of hazardous drugs used in the hospital to provide an estimate of the exposure and health benefits of using CSTD. Steps should be undertaken to ensure that there are no other differences between CSTD and control groups, so that one can obtain a reasonable estimate of the health benefits of using CSTD.

  10. Preparation of High Purity Crystalline Silicon by Electro-Catalytic Reduction of Sodium Hexafluorosilicate with Sodium below 180°C

    PubMed Central

    Chen, Yuan; Liu, Yang; Wang, Xin; Li, Kai; Chen, Pu

    2014-01-01

    The growing field of silicon solar cells requires a substantial reduction in the cost of semiconductor grade silicon, which has been mainly produced by the rod-based Siemens method. Because silicon can react with almost all of the elements and form a number of alloys at high temperatures, it is highly desired to obtain high purity crystalline silicon at relatively low temperatures through low cost process. Here we report a fast, complete and inexpensive reduction method for converting sodium hexafluorosilicate into silicon at a relatively low reaction temperature (∼200°C). This temperature could be further decreased to less than 180°C in combination with an electrochemical approach. The residue sodium fluoride is dissolved away by pure water and hydrochloric acid solution in later purifying processes below 15°C. High purity silicon in particle form can be obtained. The relative simplicity of this method might lead to a low cost process in producing high purity silicon. PMID:25153509

  11. Compact, diode-pumped, solid-state lasers for next generation defence and security sensors

    NASA Astrophysics Data System (ADS)

    Silver, M.; Lee, S. T.; Borthwick, A.; McRae, I.; Jackson, D.; Alexander, W.

    2015-06-01

    Low-cost semiconductor laser diode pump sources have made a dramatic impact in sectors such as advanced manufacturing. They are now disrupting other sectors, such as defence and security (D&S), where Thales UK is a manufacturer of sensor systems for application on land, sea, air and man portable. In this talk, we will first give an overview of the market trends and challenges in the D&S sector. Then we will illustrate how low cost pump diodes are enabling new directions in D&S sensors, by describing two diode pumped, solid- state laser products currently under development at Thales UK. The first is a new generation of Laser Target Designators (LTD) that are used to identify targets for the secure guiding of munitions. Current systems are bulky, expensive and require large battery packs to operate. The advent of low cost diode technology, merged with our novel solid-state laser design, has created a designator that will be the smallest, lowest cost, STANAG compatible laser designator on the market. The LTD delivers greater that 50mJ per pulse up to 20Hz, and has compact dimensions of 125×70×55mm. Secondly, we describe an ultra-compact, eye-safe, solid-state laser rangefinder (LRF) with reduced size, weight and power consumption compared to existing products. The LRF measures 100×55×34mm, weighs 200g, and can range to greater than 10km with a single laser shot and at a reprate of 1Hz. This also leverages off advances in laser pump diodes, but also utilises low cost, high reliability, packaging technology commonly found in the telecoms sector. As is common in the D&S sector, the products are designed to work in extreme environments, such as wide temperature range (-40 to +71°C) and high levels of shock and vibration. These disruptive products enable next- generation laser sensors such as rangefinders, target designators and active illuminated imagers.

  12. Real-Time Support of Pediatric Diabetes Self-Care by a Transport Team

    PubMed Central

    Franklin, Brandi E.; Crisler, S. Crile; Shappley, Rebekah; Armour, Meri M.; McCommon, Dana T.; Ferry, Robert J.

    2014-01-01

    OBJECTIVE The study seeks to improve access for underserved patients via novel integration of Pedi-Flite (a critical care transport team) and to validate whether this safely enhances diabetes care and effectively expands the endocrine workforce. RESEARCH DESIGN AND METHODS The study retrospectively analyzed pager service use in a cohort of established diabetic patients (n = 979) after inception of Pedi-Flite support. Outcomes included incidence and severity of recurrent diabetic ketoacidosis (DKA) and cost savings generated from reduced referrals to the emergency department (ED) and on-call endocrinologist. We generated descriptive statistics to characterize the study population and ED visits for DKA and constructed logistic regression models to examine associations of pager use and likelihood of ED visitation and nonelective inpatient admission from an ED for DKA. RESULTS Pager users comprised 30% of the patient population. They were younger but had more established diabetes than nonusers. While pager users were 2.75 times more likely than nonusers to visit the ED for DKA (P < 0.0001), their visits were less likely to lead to inpatient admissions (odds ratio 0.58; P < 0.02). More than half (n = 587) of all calls to the pager were resolved without need for further referral. Estimates suggest that 439 ED visits and 115 admissions were avoided at a potential cost savings exceeding 760,000 USD. CONCLUSIONS Integration of a transport service provides a novel, cost-effective approach to reduce disparities in diabetes care. Advantages include scalability, applicability to other disease areas and settings, and low added costs. These findings enrich an emerging evidence base for telephonic care-management models supported by allied health personnel. PMID:23959568

  13. Real-time support of pediatric diabetes self-care by a transport team.

    PubMed

    Franklin, Brandi E; Crisler, S Crile; Shappley, Rebekah; Armour, Meri M; McCommon, Dana T; Ferry, Robert J

    2014-01-01

    OBJECTIVE The study seeks to improve access for underserved patients via novel integration of Pedi-Flite (a critical care transport team) and to validate whether this safely enhances diabetes care and effectively expands the endocrine workforce. RESEARCH DESIGN AND METHODS The study retrospectively analyzed pager service use in a cohort of established diabetic patients (n = 979) after inception of Pedi-Flite support. Outcomes included incidence and severity of recurrent diabetic ketoacidosis (DKA) and cost savings generated from reduced referrals to the emergency department (ED) and on-call endocrinologist. We generated descriptive statistics to characterize the study population and ED visits for DKA and constructed logistic regression models to examine associations of pager use and likelihood of ED visitation and nonelective inpatient admission from an ED for DKA. RESULTS Pager users comprised 30% of the patient population. They were younger but had more established diabetes than nonusers. While pager users were 2.75 times more likely than nonusers to visit the ED for DKA (P < 0.0001), their visits were less likely to lead to inpatient admissions (odds ratio 0.58; P < 0.02). More than half (n = 587) of all calls to the pager were resolved without need for further referral. Estimates suggest that 439 ED visits and 115 admissions were avoided at a potential cost savings exceeding 760,000 USD. CONCLUSIONS Integration of a transport service provides a novel, cost-effective approach to reduce disparities in diabetes care. Advantages include scalability, applicability to other disease areas and settings, and low added costs. These findings enrich an emerging evidence base for telephonic care-management models supported by allied health personnel.

  14. Comparison of Technical and Clinical Outcome of Transjugular Portosystemic Shunt Placement Between a Bare Metal Stent and a PTFE-Stentgraft Device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lauermann, J., E-mail: jostlauermann@gmail.com; Potthoff, A.; Mc Cavert, M.

    PurposeTo analyse technical and clinical success of transjugular intrahepatic portosystemic shunt (TIPS) in patients with portal hypertension and compare a stent and a stentgraft with regard to clinical and technical outcome and associated costs.Materials and Methods170 patients (56 ± 12 years, 32.9 % females) treated with TIPS due to portal hypertension were reviewed. 80 patients received a stent (group 1) and 83 a stentgraft (group 2), and seven interventions were unsuccessful. Technical data, periprocedural imaging, follow-up ultrasound and clinical data were analysed with focus on technical success, patency, clinical outcome and group differences. Cost analysis was performed.ResultsPortal hypertension was mainly caused by ethyltoxicmore » liver cirrhosis with ascites as dominant symptom (80 %). Technical success was 93.5 % with mean portosystemic gradient decrease from 16.1 ± 4.8 to 5.1 ± 2.1 mmHg. No significant differences in technical success and portosystemic gradient decrease between the groups were observed. Kaplan–Meier analysis yielded significant differences in primary patency after 14 days, 6 months and 2 years in favour of the stentgraft. Both groups showed good clinical results without significant difference in 1-year survival and hepatic encephalopathy rate. Costs to establish TIPS and to manage 2-year follow-up with constant patency and clinical success were 8876 € (group 1) and 9394 € (group 2).ConclusionTIPS is a safe and effective procedure to manage portal hypertension. Stent and stentgraft enabled good technical and clinical results with a low complication rate. Primary patency rates are clearly in favour of the stentgraft, whereas the stent was more cost effective with similar clinical results in both groups.« less

  15. Critical issues in assuring long lifetime and fail-safe operation of optical communications network

    NASA Astrophysics Data System (ADS)

    Paul, Dilip K.

    1993-09-01

    Major factors in assuring long lifetime and fail-safe operation in optical communications networks are reviewed in this paper. Reliable functionality to design specifications, complexity of implementation, and cost are the most critical issues. As economics is the driving force to set the goals as well as priorities for the design, development, safe operation, and maintenance schedules of reliable networks, a balance is sought between the degree of reliability enhancement, cost, and acceptable outage of services. Protecting both the link and the network with high reliability components, hardware duplication, and diversity routing can ensure the best network availability. Case examples include both fiber optic and lasercom systems. Also, the state-of-the-art reliability of photonics in space environment is presented.

  16. Current trends in treatment of hypertension in Karachi and cost minimization possibilities.

    PubMed

    Hussain, Izhar M; Naqvi, Baqir S; Qasim, Rao M; Ali, Nasir

    2015-01-01

    This study finds out drug usage trends in Stage I Hypertensive Patients without any compelling indications in Karachi, deviations of current practices from evidence based antihypertensive therapeutic guidelines and looks for cost minimization opportunities. In the present study conducted during June 2012 to August 2012, two sets were used. Randomized stratified independent surveys were conducted in doctors and general population - including patients, using pretested questionnaires. Sample sizes for doctors and general population were 100 and 400 respectively. Statistical analysis was conducted on Statistical Package for Social Science (SPSS). Financial impact was also analyzed. On the basis of patients' doctors' feedback, Beta Blockers, and Angiotensin Converting Enzyme Inhibitors were used more frequently than other drugs. Thiazides and low-priced generics were hardly prescribed. Beta blockers were prescribed widely and considered cost effective. This trend increases cost by two to ten times. Feedbacks showed that therapeutic guidelines were not followed by the doctors practicing in the community and hospitals in Karachi. Thiazide diuretics were hardly used. Beta blockers were widely prescribed. High priced market leaders or expensive branded generics were commonly prescribed. Therefore, there are great opportunities for cost minimization by using evidence-based clinically effective and safe medicines.

  17. The cost-effectiveness of New York City's Safe Routes to School Program.

    PubMed

    Muennig, Peter A; Epstein, Michael; Li, Guohua; DiMaggio, Charles

    2014-07-01

    We evaluated the cost-effectiveness of a package of roadway modifications in New York City funded under the Safe Routes to School (SRTS) program. We used a Markov model to estimate long-term impacts of SRTS on injury reduction and the associated savings in medical costs, lifelong disability, and death. Model inputs included societal costs (in 2013 US dollars) and observed spatiotemporal changes in injury rates associated with New York City's implementation of SRTS relative to control intersections. Structural changes to roadways were assumed to last 50 years before further investment is required. Therefore, costs were discounted over 50 consecutive cohorts of modified roadway users under SRTS. SRTS was associated with an overall net societal benefit of $230 million and 2055 quality-adjusted life years gained in New York City. SRTS reduces injuries and saves money over the long run.

  18. Composite Structures and Materials Research at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Starnes, James H., Jr.; Dexter, H. Benson; Johnston, Norman J.; Ambur, Damodar R.; Cano, roberto J.

    2003-01-01

    A summary of recent composite structures and materials research at NASA Langley Research Center is presented. Fabrication research to develop low-cost automated robotic fabrication procedures for thermosetting and thermoplastic composite materials, and low-cost liquid molding processes for preformed textile materials is described. Robotic fabrication procedures discussed include ply-by-ply, cure-on-the-fly heated placement head and out-of-autoclave electron-beam cure methods for tow and tape thermosetting and thermoplastic materials. Liquid molding fabrication processes described include Resin Film Infusion (RFI), Resin Transfer Molding (RTM) and Vacuum-Assisted Resin Transfer Molding (VARTM). Results for a full-scale composite wing box are summarized to identify the performance of materials and structures fabricated with these low-cost fabrication methods.

  19. Composite Structures and Materials Research at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Starnes, James H., Jr.; Dexter, H. Benson; Johnston, Norman J.; Ambur, Damodar R.; Cano, Roberto J.

    2001-01-01

    A summary of recent composite structures and materials research at NASA Langley Research Center is presented. Fabrication research to develop low-cost automated robotic fabrication procedures for thermosetting and thermoplastic composite materials, and low-cost liquid molding processes for preformed textile materials is described. Robotic fabrication procedures discussed include ply-by-ply, cure-on-the-fly heated placement head and out-of-autoclave electron-beam cure methods for tow and tape thermosetting and thermoplastic materials. Liquid molding fabrication processes described include Resin Film Infusion (RFI) Resin Transfer Molding (RTM) and Vacuum-Assisted Resin Transfer Molding (VARTM). Results for a full-scale composite wing box are summarized to identify the performance of materials and structures fabricated with these low-cost fabrication methods.

  20. The Array Automated Assembly Task for the Low Cost Solar Array Project, Phase 2

    NASA Technical Reports Server (NTRS)

    Campbell, R. B. (Editor); Farukhi, S. (Editor)

    1978-01-01

    During the program a process sequence was proposed and tested for the fabrication of dendritic welb silicon into solar modules. This sequence was analyzed as to yield and cost and these data suggest that the price goals of 1986 are attainable. Specifically, it was shown that a low cost POCL3 is a suitable replacement for the semiconductor grade, and that a suitable CVD oxide can be deposited from a silane/air mixture using a Silox reactor. A dip coating method was developed for depositing an antireflection coating from a metalorganic precursor. Application of photoresist to define contact grids was made cost effective through use of a dip coating technique. Electroplating of both Ag and Cu was shown feasible and cost effective for producing the conductive metal grids on the solar cells. Laser scribing was used to separate the cells from the dendrites without degradation. Ultrasonic welding methods were shown to be feasible for interconnecting the cells. A study of suitable low cost materials for encapsulation suggest that soda lime glass and phenolic filled board are preferred.

  1. Evaluation and comparison of safety, convenience and cost of administering intravenous pamidronate infusions to children in the home and ambulatory care settings.

    PubMed

    Rush, Eric T; DeHaai, Kristi; Kreikemeier, Rose M; Lutz, Richard E

    2012-01-01

    The use of bisphosphonates in children to treat low bone mineral density has increased. Safety and efficacy of pamidronate has been previously demonstrated. However, little research has been done on pamidronate infusion in the home health setting for patients with metabolic bone disease. Data were collected via a survey to assess satisfaction and convenience of infusions. Adverse events were measured by collecting calcium levels before and after infusions. Infusion costs were estimated from the standard orders from one home health agency and our infusion center. We found no difference in the rates of hypocalcemia between the two groups. The survey results showed high satisfaction for both groups, with higher scores in the home health group for convenience and stress. Home health infusions showed lower cost and less absenteeism from school and work. Home health-based pamidronate infusion appears to be safe, less expensive, and is associated with high patient satisfaction.

  2. Final report on evaluation of cyclocraft support of oil and gas operations in wetland areas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eggington, W.J.; Stevens, P.M.; John, C.J.

    1994-10-01

    The cyclocraft is a proven hybrid aircraft, capable of VTOL, lifting heavy and bulky loads, highly controllable, having high safety characteristics and low operating costs. Mission Research Corporation (MRC), under Department of Energy sponsorship, is evaluating the potential use of cyclocraft in the transport of drill rigs, mud, pipes and other materials and equipment, in a cost effective and environmentally safe manner, to support oil and gas drilling, production, and transportation operations in wetland areas. Based upon the results of an earlier parametric study, a cyclocraft design, having a payload capacity of 45 tons and designated H.1 Cyclocraft, was selectedmore » for further study, including the preparation of a preliminary design and a development plan, and the determination of operating costs. This report contains all of the results derived from the program to evaluate the use of cyclocraft in the support of oil and gas drilling and production operations in wetland areas.« less

  3. Surfactant irritation: in vitro corneosurfametry and in vivo bioengineering.

    PubMed

    Gabard, B; Chatelain, E; Bieli, E; Haas, S

    2001-02-01

    Irritant reactions to surfactants, cleansing products, soaps and detergents are common in clinical and occupational dermatology. Mildness has become a major benefit claimed, and testing for mildness now ranks among the first concerns of the manufacturing industry. A wealth of publications deals with this problem, trying to improve the methodology, reduce the costs of testing and facilitate decision-making. Differences in vivo can be measured clinically and/or instrumentally. This is difficult, as commercially available products are generally safe to use and none are harsh in the absolute sense. Nineteen different products (syndets, shampoos, personal cleansers), all claiming to be mild, were tested in vitro by a newly introduced method, corneosurfametry. For evaluating the aggressiveness of the products, the calculation of an index of irritation (IOI) was proposed. A concentration-effect curve of sodium lauryl sulfate (SLS) as standard and model surfactant was obtained. Some of the products were further tested in vivo with a flex wash test and with a soap chamber test and compared to SLS. Bioengineering methods (transepidermal water loss TEWL, skin color) were used to evaluate the results. The results of the corneosurfametry allowed us to classify the products in three categories, with increasing aggressiveness towards the stratum corneum, according to their IOIs. The in vivo tests were not able to discriminate between the products, but ranks from the results of the bioengineering measurements showed a good correlation between TEWL changes, but not between colour changes, and IOIs from corneosurfametry. Corneosurfametry emerged as a simple, low-cost and fast method for ranking commercial products according to their mildness. However, the skin bioengineering techniques showed that some products could lead to skin reactions, such as erythema, that could not be detected by the in vitro technique.

  4. Investigation of safe-life fail-safe criteria for the space shuttle

    NASA Technical Reports Server (NTRS)

    1972-01-01

    An investigation was made to determine the effects of a safe-life design approach and a fail-safe design approach on the space shuttle booster vehicle structure, and to recommend any changes to the structural design criteria. Two configurations of the booster vehicle were considered, one incorporating a delta wing (B-9U configuration) and the other a swept wing (B-16B configuration). Several major structural components of the booster were studied to determine the fatigue life, safe-life, and fail-safe capabilities of the baseline design. Each component was investigated to determine the practicability of applying a safe-life or fail-safe design philosophy, the changes such design approaches might require, and the impact of these changes on weight, cost, development plans, and performance.

  5. The use of artificial intelligence technology to predict lymph node spread in men with clinically localized prostate carcinoma.

    PubMed

    Crawford, E D; Batuello, J T; Snow, P; Gamito, E J; McLeod, D G; Partin, A W; Stone, N; Montie, J; Stock, R; Lynch, J; Brandt, J

    2000-05-01

    The current study assesses artificial intelligence methods to identify prostate carcinoma patients at low risk for lymph node spread. If patients can be assigned accurately to a low risk group, unnecessary lymph node dissections can be avoided, thereby reducing morbidity and costs. A rule-derivation technology for simple decision-tree analysis was trained and validated using patient data from a large database (4,133 patients) to derive low risk cutoff values for Gleason sum and prostate specific antigen (PSA) level. An empiric analysis was used to derive a low risk cutoff value for clinical TNM stage. These cutoff values then were applied to 2 additional, smaller databases (227 and 330 patients, respectively) from separate institutions. The decision-tree protocol derived cutoff values of < or = 6 for Gleason sum and < or = 10.6 ng/mL for PSA. The empiric analysis yielded a clinical TNM stage low risk cutoff value of < or = T2a. When these cutoff values were applied to the larger database, 44% of patients were classified as being at low risk for lymph node metastases (0.8% false-negative rate). When the same cutoff values were applied to the smaller databases, between 11 and 43% of patients were classified as low risk with a false-negative rate of between 0.0 and 0.7%. The results of the current study indicate that a population of prostate carcinoma patients at low risk for lymph node metastases can be identified accurately using a simple decision algorithm that considers preoperative PSA, Gleason sum, and clinical TNM stage. The risk of lymph node metastases in these patients is < or = 1%; therefore, pelvic lymph node dissection may be avoided safely. The implications of these findings in surgical and nonsurgical treatment are significant.

  6. DEVELOPMENT OF A METHOD TO DESIGN A LOW-CARBON SOCIETY IN SMALL COMMUNITY AND ITS APPLICATION TO PUTRAJAYA, MALAYSIA

    NASA Astrophysics Data System (ADS)

    Hayashi, Yuri; Simson, Janice. J.; Gomi, Kei; Matsuoka, Yuzuru

    In this study, we developed the method to design Low-carbon society for small communities almost without industry, with regarding of costs for countermeasures. Then we applied it to Putrajaya, Malaysia, and estimate Socio-economic indicators, energy demand, CO2 emission in year 2007 and 2025. For countermeasure case in 2025, we set three cases according to their priority; Transport, Renewable energy, Building, and calculated costs for countermeasures also. As a result, it was shown that it is possible to reduce 45% of CO2 emission by 2025 compared to 2007 level. Renewable energy priority case needs the highest cost, and Building and Transport was estimated to be the second and third highest. C-ExSS will help more realistic discussion on the policy and countermeasures for developing low-carbon society based on their costs.

  7. A Simple, Low-Cost Platform for Real-Time Isothermal Nucleic Acid Amplification

    PubMed Central

    Craw, Pascal; Mackay, Ruth E.; Naveenathayalan, Angel; Hudson, Chris; Branavan, Manoharanehru; Sadiq, S. Tariq; Balachandran, Wamadeva

    2015-01-01

    Advances in microfluidics and the introduction of isothermal nucleic acid amplification assays have resulted in a range of solutions for nucleic acid amplification tests suited for point of care and field use. However, miniaturisation of instrumentation for such assays has not seen such rapid advances and fluorescence based assays still depend on complex, bulky and expensive optics such as fluorescence microscopes, photomultiplier tubes and sensitive lens assemblies. In this work we demonstrate a robust, low cost platform for isothermal nucleic acid amplification on a microfluidic device. Using easily obtainable materials and commercial off-the-shelf components, we show real time fluorescence detection using a low cost photodiode and operational amplifier without need for lenses. Temperature regulation on the device is achieved using a heater fabricated with standard printed circuit board fabrication methods. These facile construction methods allow fabrications at a cost compatible with widespread deployment to resource poor settings. PMID:26389913

  8. Evaluation of fatigue-prone details using a low-cost thermoelastic stress analysis system.

    DOT National Transportation Integrated Search

    2016-11-01

    This study was designed to develop a novel approach for in situ evaluation of stress fields in the vicinity of fatigue-prone details on highway bridges using a low-cost microbolometer thermal imager. : The method was adapted into a field-deployable i...

  9. Laboratory Demonstration of Low-Cost Method for Producing Thin Film on Nonconductors.

    ERIC Educational Resources Information Center

    Ebong, A. U.; And Others

    1991-01-01

    A low-cost procedure for metallizing a silicon p-n junction diode by electroless nickel plating is reported. The procedure demonstrates that expensive salts can be excluded without affecting the results. The experimental procedure, measurement, results, and discussion are included. (Author/KR)

  10. Residential Tornado Safe Rooms from Commodity Wood Products: Wall Development and Impact Testing

    Treesearch

    Robert H. Falk; James J. Bridwell; John C. Hermanson

    2015-01-01

    In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms and shelters have helped reduce the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a residential tornado safe room...

  11. New simple and low-cost methods for periodic checks of Cyclone® Plus Storage Phosphor System.

    PubMed

    Edalucci, Elisabetta; Maffione, Anna Margherita; Fornasier, Maria Rosa; De Denaro, Mario; Scian, Giovanni; Dore, Franca; Rubello, Domenico

    2017-01-01

    The recent large use of the Cyclone® Plus Storage Phosphor System, especially in European countries, as imaging system for quantification of radiochemical purity of radiopharmaceuticals raised the problem of setting the periodic controls as required by European Legislation. We described simple, low-cost methods for Cyclone® Plus quality controls, which can be useful to evaluate the performance measurement of this imaging system.

  12. a Framework for Low-Cost Multi-Platform VR and AR Site Experiences

    NASA Astrophysics Data System (ADS)

    Wallgrün, J. O.; Huang, J.; Zhao, J.; Masrur, A.; Oprean, D.; Klippel, A.

    2017-11-01

    Low-cost consumer-level immersive solutions have the potential to revolutionize education and research in many fields by providing virtual experiences of sites that are either inaccessible, too dangerous, or too expensive to visit, or by augmenting in-situ experiences using augmented and mixed reality methods. We present our approach for creating low-cost multi-platform virtual and augmented reality site experiences of real world places for education and research purposes, making extensive use of Structure-from-Motion methods as well as 360° photography and videography. We discuss several example projects, for the Mayan City of Cahal Pech, Iceland's Thrihnukar volcano, the Santa Marta informal settlement in Rio, and for the Penn State Campus, and we propose a framework for creating and maintaining such applications by combining declarative content specification methods with a central linked-data based spatio-temporal information system.

  13. Studies on magnetic properties of chemically synthesized crystalline calcium ferrite nanoparticles

    NASA Astrophysics Data System (ADS)

    Debnath, A.; Bera, A.; Chattopadhyay, K. K.; Saha, B.

    2016-05-01

    Spinel-type ferrites have taken a very important role for modern electronic industry. Most of these ferrites exhibit low-loss dielectric properties, high resistivity, low eddy current and also high temperature ferromagnetism. Calcium ferrite is one such important metal oxide which is environmentally safe, chemically stable, low cost and greatly abundant. This outstanding material of calcium ferrite is synthesized by a simple chemical precipitation method using NaOH as the precipitating agent. Ferric chloride anhydrous (FeCl3) and Calcium chloride dihydrate (CaCl2.2H2O) were used as iron and calcium sources respectively. The samples were heated at 200°C for 8h to obtain homogeneous powder of Calcium ferrite. The powders were characterized by using X-ray diffraction (XRD), field emission scanning electron microscope (FESEM), Transmission electrical microscopy (TEM), and Fourier transform infrared spectroscopic (FTIR) measurements. The polycrystalline nature of the sample was confirmed by X-ray diffraction study. The magnetic properties of the sample were investigated by vibrating sample magnetometer (VSM) measurements. Magnetization curve of the prepared sample depicts that as synthesized calcium ferrite nanoparticles have saturation magnetic moment of 1.74 emu/g and the coercivity of 35.08 Oe with superparamagnetic behavior. The synthesized calcium ferrite nanoparticles with such magnetic properties will be a candidate material for different applications in electronics and exploring its functionality in the field of recently developing semiconductor device physics and spintronics.

  14. Mucuna pruriens for Parkinson's disease: Low-cost preparation method, laboratory measures and pharmacokinetics profile.

    PubMed

    Cassani, Erica; Cilia, Roberto; Laguna, Janeth; Barichella, Michela; Contin, Manuela; Cereda, Emanuele; Isaias, Ioannis U; Sparvoli, Francesca; Akpalu, Albert; Budu, Kwabena Ofosu; Scarpa, Maria Teresa; Pezzoli, Gianni

    2016-06-15

    Parkinson's disease (PD) is a progressive neurological condition. Levodopa (LD) is the gold standard therapy for PD patients. Most PD patients in low-income areas cannot afford long-term daily Levodopa therapy. The aim of our study was to investigate if Mucuna pruriens (MP), a legume with high LD content that grows in tropical regions worldwide, might be potential alternative for poor PD patients. We analyzed 25 samples of MP from Africa, Latin America and Asia. We measured the content in LD in various MP preparations (dried, roasted, boiled). LD pharmacokinetics and motor response were recorded in four PD patients, comparing MP vs. LD+Dopa-Decarboxylase Inhibitor (DDCI) formulations. Median LD concentration in dried MP seeds was 5.29%; similar results were obtained in roasted powder samples (5.3%), while boiling reduced LD content up to 70%. Compared to LD+DDCI, MP extract at similar LD dose provided less clinical benefit, with a 3.5-fold lower median AUC. Considering the lack of a DDCI, MP therapy may provide clinical benefit only when content of LD is at least 3.5-fold the standard LD+DDCI. If long-term MP proves to be safe and effective in controlled clinical trials, it may be a sustainable alternative therapy for PD in low-income countries. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Towards biomarker-based tests that can facilitate decisions about prevention and management of preeclampsia in low-resource settings.

    PubMed

    Acestor, Nathalie; Goett, Jane; Lee, Arthur; Herrick, Tara M; Engelbrecht, Susheela M; Harner-Jay, Claudia M; Howell, Bonnie J; Weigl, Bernhard H

    2016-01-01

    In recent years, an increasing amount of literature is emerging on candidate urine and blood-based biomarkers associated with incidence and severity of preeclampsia (PE) in pregnant women. While enthusiasm on the usefulness of several of these markers in predicting PE is evolving, essentially all work so far has focused on the needs of high-resource settings and high-income countries, resulting primarily in multi-parameter laboratory assays based on proteomic and metabolomics analysis techniques. These highly complex methods, however, require laboratory capabilities that are rarely available or affordable in low-resource settings (LRS). The importance of quantifying maternal and perinatal risks and identifying which pregnancies can be safely prolonged is also much greater in LRS, where intensive care facilities that can rapidly respond to PE-related health threats for women and infants are limited. For these reasons, simple, low cost, sensitive, and specific point-of-care (POC) tests are needed that can be performed by antenatal health care providers in LRS and that can facilitate decisions about detection and management of PE. Our study aims to provide a comprehensive systematic review of current and emerging blood and urine biomarkers for PE, not only on the basis of their clinical performance, but also of their suitability to be used in LRS-compatible test formats, such as lateral flow and other variants of POC rapid assays.

  16. Low-Cost Ultra-Wide Genotyping Using Roche/454 Pyrosequencing for Surveillance of HIV Drug Resistance

    PubMed Central

    Dudley, Dawn M.; Chin, Emily N.; Bimber, Benjamin N.; Sanabani, Sabri S.; Tarosso, Leandro F.; Costa, Priscilla R.; Sauer, Mariana M.; Kallas, Esper G.; O.’Connor, David H.

    2012-01-01

    Background Great efforts have been made to increase accessibility of HIV antiretroviral therapy (ART) in low and middle-income countries. The threat of wide-scale emergence of drug resistance could severely hamper ART scale-up efforts. Population-based surveillance of transmitted HIV drug resistance ensures the use of appropriate first-line regimens to maximize efficacy of ART programs where drug options are limited. However, traditional HIV genotyping is extremely expensive, providing a cost barrier to wide-scale and frequent HIV drug resistance surveillance. Methods/Results We have developed a low-cost laboratory-scale next-generation sequencing-based genotyping method to monitor drug resistance. We designed primers specifically to amplify protease and reverse transcriptase from Brazilian HIV subtypes and developed a multiplexing scheme using multiplex identifier tags to minimize cost while providing more robust data than traditional genotyping techniques. Using this approach, we characterized drug resistance from plasma in 81 HIV infected individuals collected in São Paulo, Brazil. We describe the complexities of analyzing next-generation sequencing data and present a simplified open-source workflow to analyze drug resistance data. From this data, we identified drug resistance mutations in 20% of treatment naïve individuals in our cohort, which is similar to frequencies identified using traditional genotyping in Brazilian patient samples. Conclusion The developed ultra-wide sequencing approach described here allows multiplexing of at least 48 patient samples per sequencing run, 4 times more than the current genotyping method. This method is also 4-fold more sensitive (5% minimal detection frequency vs. 20%) at a cost 3–5× less than the traditional Sanger-based genotyping method. Lastly, by using a benchtop next-generation sequencer (Roche/454 GS Junior), this approach can be more easily implemented in low-resource settings. This data provides proof-of-concept that next-generation HIV drug resistance genotyping is a feasible and low-cost alternative to current genotyping methods and may be particularly beneficial for in-country surveillance of transmitted drug resistance. PMID:22574170

  17. The Accuracy of 6 Inexpensive Pulse Oximeters Not Cleared by the Food and Drug Administration: The Possible Global Public Health Implications.

    PubMed

    Lipnick, Michael S; Feiner, John R; Au, Paul; Bernstein, Michael; Bickler, Philip E

    2016-08-01

    Universal access to pulse oximetry worldwide is often limited by cost and has substantial public health consequences. Low-cost pulse oximeters have become increasingly available with limited regulatory agency oversight. The accuracy of these devices often has not been validated, raising questions about performance. The accuracy of 6 low-cost finger pulse oximeters during stable arterial oxygen saturations (SaO2) between 70% and 100% was evaluated in 22 healthy subjects. Oximeters tested were the Contec CMS50DL, Beijing Choice C20, Beijing Choice MD300C23, Starhealth SH-A3, Jumper FPD-500A, and Atlantean SB100 II. Inspired oxygen, nitrogen, and carbon dioxide partial pressures were monitored and adjusted via a partial rebreathing circuit to achieve 10 to 12 stable target SaO2 plateaus between 70% and 100% and PaCO2 values of 35 to 45 mm Hg. Comparisons of pulse oximeter readings (SpO2) with arterial SaO2 (by Radiometer ABL90 and OSM3) were used to calculate bias (SpO2 - SaO2) mean, precision (SD of the bias), and root mean square error (ARMS). Pulse oximeter readings corresponding to 536 blood samples were analyzed. Four of the 6 oximeters tested showed large errors (up to -6.30% mean bias, precision 4.30%, 7.53 ARMS) in estimating saturation when SaO2 was reduced <80%, and half of the oximeters demonstrated large errors when estimating saturations between 80% and 90%. Two of the pulse oximeters tested (Contec CMS50DL and Beijing Choice C20) demonstrated ARMS of <3% at SaO2 between 70% and 100%, thereby meeting International Organization for Standardization (ISO) criteria for accuracy. Many low-cost pulse oximeters sold to consumers demonstrate highly inaccurate readings. Unexpectedly, the accuracy of some low-cost pulse oximeters tested here performed similarly to more expensive, ISO-cleared units when measuring hypoxia in healthy subjects. None of those tested here met World Federation of Societies of Anaesthesiologists standards, and the ideal testing conditions do not necessarily translate these findings to the clinical setting. Nonetheless, further development of accurate, low-cost oximeters for use in clinical practice is feasible and, if pursued, could improve access to safe care, especially in low-income countries.

  18. An improved method of measuring heart rate using a webcam

    NASA Astrophysics Data System (ADS)

    Liu, Yi; Ouyang, Jianfei; Yan, Yonggang

    2014-09-01

    Measuring heart rate traditionally requires special equipment and physical contact with the subject. Reliable non-contact and low-cost measurements are highly desirable for convenient and comfortable physiological self-assessment. Previous work has shown that consumer-grade cameras can provide useful signals for remote heart rate measurements. In this paper a simple and robust method of measuring the heart rate using low-cost webcam is proposed. Blood volume pulse is extracted by proper Region of Interest (ROI) and color channel selection from image sequences of human faces without complex computation. Heart rate is subsequently quantified by spectrum analysis. The method is successfully applied under natural lighting conditions. Results of experiments show that it takes less time, is much simpler, and has similar accuracy to the previously published and widely used method of Independent Component Analysis (ICA). Benefitting from non-contact, convenience, and low-costs, it provides great promise for popularization of home healthcare and can further be applied to biomedical research.

  19. Guided and unguided internet-based vestibular rehabilitation versus usual care for dizzy adults of 50 years and older: a protocol for a three-armed randomised trial

    PubMed Central

    van der Wouden, Johannes C; Bosmans, Judith E; Smalbrugge, Martin; van Diest, Willianne; Essery, Rosie; Yardley, Lucy; van der Horst, Henriëtte E; Maarsingh, Otto R

    2017-01-01

    Introduction Dizziness is a common symptom in general practice with a high prevalence among older adults. The most common cause of dizziness in general practice is peripheral vestibular disease. Vestibular rehabilitation (VR) is a safe and effective treatment for peripheral vestibular disease that entails specific exercises to maximise the central nervous system compensation for the effects of vestibular pathology. An internet-based VR intervention has recently been shown to be safe and effective. Online interventions are low cost and easily accessible, but prone to attrition and non-adherence. A combination of online and face-to-face therapy, known as blended care, may balance these advantages and disadvantages. Methods and analysis A single-blind, three-arm, randomised controlled trial among patients aged 50 years and over presenting with dizziness of vestibular origin in general practice will be performed. In this study, we will compare the clinical and cost-effectiveness of stand-alone internet-based VR and internet-based VR with physiotherapeutic support (‘blended care’) with usual care during 6 months of follow-up. We will use a translated Dutch version of a British online VR intervention. Randomisation will be stratified by dizziness severity. The primary outcome measure is the Vertigo Symptoms Scale—Short Form. Intention-to-treat analysis will be performed, adjusting for confounders. The economic evaluation will be conducted from a societal perspective. We will perform an additional analysis on the data to identify predictors of successful treatment in the same population to develop a clinical decision rule for general practitioners. Ethics and dissemination The ethical committee of the VU University Medical Center approved ethics and dissemination of the study protocol. The insights and results of this study will be widely disseminated through international peer-reviewed journals and conference presentations. Trial registration number Pre-results, NTR5712. PMID:28110290

  20. Phosphate-Mediated Remediation of Metals and Radionuclides

    DOE PAGES

    Martinez, Robert J.; Beazley, Melanie J.; Sobecky, Patricia A.

    2014-01-01

    Worldwide industrialization activities create vast amounts of organic and inorganic waste streams that frequently result in significant soil and groundwater contamination. Metals and radionuclides are of particular concern due to their mobility and long-term persistence in aquatic and terrestrial environments. As the global population increases, the demand for safe, contaminant-free soil and groundwater will increase as will the need for effective and inexpensive remediation strategies. Remediation strategies that include physical and chemical methods (i.e., abiotic) or biological activities have been shown to impede the migration of radionuclide and metal contaminants within soil and groundwater. However, abiotic remediation methods are oftenmore » too costly owing to the quantities and volumes of soils and/or groundwater requiring treatment. The in situ sequestration of metals and radionuclides mediated by biological activities associated with microbial phosphorus metabolism is a promising and less costly addition to our existing remediation methods. This review highlights the current strategies for abiotic and microbial phosphate-mediated techniques for uranium and metal remediation.« less

  1. Low-cost manufacturing of the point focus concentrating module and its key component, the Fresnel lens. Final subcontract report, 31 January 1991--6 May 1991

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saifee, T.; Konnerth, A. III

    1991-11-01

    Solar Kinetics, Inc. (SKI) has been developing point-focus concentrating PV modules since 1986. SKI is currently in position to manufacture between 200 to 600 kilowatts annually of the current design by a combination of manual and semi-automated methods. This report reviews the current status of module manufacture and specifies the required approach to achieve a high-volume manufacturing capability and low cost. The approach taken will include process development concurrent with module design for automated manufacturing. The current effort reviews the major manufacturing costs and identifies components and processes whose improvements would produce the greatest effect on manufacturability and cost reduction.more » The Fresnel lens is one such key component. Investigating specific alternative manufacturing methods and sources has substantially reduced the lens costs and has exceeded the DOE cost-reduction goals. 15 refs.« less

  2. Allele-specific methylated multiplex real-time quantitative PCR (ASMM RTQ-PCR), a powerful method for diagnosing loss of imprinting of the 11p15 region in Russell Silver and Beckwith Wiedemann syndromes.

    PubMed

    Azzi, Salah; Steunou, Virginie; Rousseau, Alexandra; Rossignol, Sylvie; Thibaud, Nathalie; Danton, Fabienne; Le Jule, Marilyne; Gicquel, Christine; Le Bouc, Yves; Netchine, Irène

    2011-02-01

    Many human syndromes involve a loss of imprinting (LOI) due to a loss (LOM) or a gain of DNA methylation (GOM). Most LOI occur as mosaics and can therefore be difficult to detect with conventional methods. The human imprinted 11p15 region is crucial for the control of fetal growth, and LOI at this locus is associated with two clinical disorders with opposite phenotypes: Beckwith-Wiedemann syndrome (BWS), characterized by fetal overgrowth and a high risk of tumors, and Russell-Silver syndrome (RSS), characterized by intrauterine and postnatal growth restriction. Until recently, we have been using Southern blotting for the diagnosis of RSS and BWS. We describe here a powerful quantitative technique, allele-specific methylated multiplex real-time quantitative PCR (ASMM RTQ-PCR), for the diagnosis of these two complex disorders. We first checked the specificity of the probes and primers used for ASMM RTQ-PCR. We then carried out statistical validation for this method, on both retrospective and prospective populations of patients. This analysis demonstrated that ASMM RTQ-PCR is more sensitive than Southern blotting for detecting low degree of LOI. Moreover, ASMM RTQ-PCR is a very rapid, reliable, simple, safe, and cost effective method. © 2011 Wiley-Liss, Inc.

  3. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    PubMed

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  4. The Reliability, Impact, and Cost-Effectiveness of Value-Added Teacher Assessment Methods

    ERIC Educational Resources Information Center

    Yeh, Stuart S.

    2012-01-01

    This article reviews evidence regarding the intertemporal reliability of teacher rankings based on value-added methods. Value-added methods exhibit low reliability, yet are broadly supported by prominent educational researchers and are increasingly being used to evaluate and fire teachers. The article then presents a cost-effectiveness analysis…

  5. A review of promising new immunoassay technology for monitoring forest herbicides

    Treesearch

    Charles K. McMahon

    1993-01-01

    Rising costs of classical instrumental methods of chemical analysis coupled with an increasing need for environmental monitoring has lead to the development of highly sensitive, low-cost immunochemical methods of analysis for the detection of environmental contaminants. These methods known simply as immunoassays are chemical assays which use antibodies as reagents. A...

  6. Automated mixed traffic vehicle control and scheduling study

    NASA Technical Reports Server (NTRS)

    Peng, T. K. C.; Chon, K.

    1976-01-01

    The operation and the expected performance of a proposed automatic guideway transit system which uses low speed automated mixed traffic vehicles (AMTVs) were analyzed. Vehicle scheduling and headway control policies were evaluated with a transit system simulation model. The effect of mixed traffic interference on the average vehicle speed was examined with a vehicle pedestrian interface model. Control parameters regulating vehicle speed were evaluated for safe stopping and passenger comfort. Some preliminary data on the cost and operation of an experimental AMTV system are included. These data were the result of a separate task conducted at JPL, and were included as background information.

  7. Assured crew return vehicle

    NASA Technical Reports Server (NTRS)

    Cerimele, Christopher J. (Inventor); Ried, Robert C. (Inventor); Peterson, Wayne L. (Inventor); Zupp, George A., Jr. (Inventor); Stagnaro, Michael J. (Inventor); Ross, Brian P. (Inventor)

    1991-01-01

    A return vehicle is disclosed for use in returning a crew to Earth from low earth orbit in a safe and relatively cost effective manner. The return vehicle comprises a cylindrically-shaped crew compartment attached to the large diameter of a conical heat shield having a spherically rounded nose. On-board inertial navigation and cold gas control systems are used together with a de-orbit propulsion system to effect a landing near a preferred site on the surface of the Earth. State vectors and attitude data are loaded from the attached orbiting craft just prior to separation of the return vehicle.

  8. Utilizing Non-Contact Stress Measurement System (NSMS) as a Health Monitor

    NASA Technical Reports Server (NTRS)

    Hayes, Terry; Hayes, Bryan; Bynum, Ken

    2011-01-01

    Continuously monitor all 156 blades throughout the entire operating envelope without adversely affecting tunnel conditions or compromise compressor shell integrity, Calculate dynamic response and identify the frequency/mode to determine individual blade deflection amplitudes, natural frequencies, phase, and damping (Q), Log static deflection to build a database of deflection values at certain compressor conditions to use as basis for real-time online Blade Stack monitor, Monitor for stall, surge, flutter, and blade damage, Operate with limited user input, low maintenance cost, safe illumination of probes, easy probe replacement, and require little or no access to compressor.

  9. Giardiasis: a return of waterborne disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spofford, W.O. Jr.

    Complacency about safe water supply has turned to concern over possible chemical contamination and waterborne disease, giardiasis, caused by a protozoan. A case study of an outbreak of giardiasis in Pennsylvania raises questions about water treatment strategies, which must necessarily vary because of differences in public water systems. While giardiasis is an unpleasant and uncomfortable disease, it is not as serious as typhoid, dysentery, and other diseases. The costs of analyzing water systems to detect and eliminate the risk of contamination may exceed the costs of the disease itself. Americans have grown used to safe drinking water, however, and maymore » conclude that the benefits are worth the cost. 2 figures, 1 table.« less

  10. Economic comparison of methods of wound closure: wound closure strips vs. sutures and wound adhesives.

    PubMed

    Zempsky, William T; Zehrer, Cindy L; Lyle, Christopher T; Hedbloom, Edwin C

    2005-09-01

    Our objective was to review and assess the treatment of low-tension wounds and evaluate the cost-effectiveness of wound closure methods. We used a health economic model to estimate cost/closure of adhesive wound closure strips, tissue adhesives and sutures. The model incorporated cost-driving variables: application time, costs and the likelihood and costs of dehiscence and infection. The model was populated with variable estimates derived from the literature. Cost estimates and cosmetic results were compared. Parameter values were estimated using national healthcare and labour statistics. Sensitivity analyses were used to verify the results. Our analysis suggests that adhesive wound closure strips had the lowest average cost per laceration ($7.54), the lowest cost per infected laceration ($53.40) and the lowest cost per laceration with dehiscence ($25.40). The costs for sutures were $24.11, $69.91 and $41.91, respectively; the costs for tissue adhesives were $28.77, $74.68 and $46.68, respectively. The cosmetic outcome for all three treatments was equivalent. We conclude adhesive wound closure strips were both a cost-saving and a cost-effective alternative to sutures and tissue adhesives in the closure of low-tension lacerations.

  11. Performance Evaluation and Community Application of Low-Cost Sensors for Ozone and Nitrogen Dioxide

    EPA Science Inventory

    This study reports on the performance of electrochemical-based low-cost sensors and their use in a community application. CairClip sensors were collocated with federal reference and equivalent methods and operated in a network of sites by citizen scientists (community members) in...

  12. Development of a Low-Cost Attitude Sensor for Agricultural Vehicles

    USDA-ARS?s Scientific Manuscript database

    The objective of this research was to develop a low-cost attitude sensor for agricultural vehicles. The attitude sensor was composed of three vibratory gyroscopes and two inclinometers. A sensor fusion algorithm was developed to estimate tilt angles (roll and pitch) by least-squares method. In the a...

  13. Paraffin-related injury in low-income South African communities: knowledge, practice and perceived risk

    PubMed Central

    Swart, Dehran; Hui, Siu-kuen Azor; Simpson, Jennifer; Hobe, Phumla

    2009-01-01

    Abstract Objective To explore what individuals at risk of injury from using paraffin (also known as kerosene) know about paraffin safety, what they do to protect themselves and their families from paraffin-related injury, and how they perceive their risk for such injury. Also, to explore interrelations between these factors and age, sex, education and income. Methods A sample of 238 individuals was randomly recruited from low-income housing districts near Cape Town, South Africa in 2007. Trained research assistants interviewed participants to explore their knowledge about paraffin-related safety and their perceived risk of injury from using paraffin. Researchers inspected participants’ homes to evaluate paraffin safety practices. Descriptive and correlational analyses were conducted. Findings Participants had relatively low levels of knowledge about paraffin-related safety. They had high levels of unsafe practice and their perceived risk of injury was moderate. Knowledge of paraffin safety and safe practices were positively correlated with each other. Greater knowledge showed a negative correlation with the perception of being at risk for injury, but safe practices showed no correlation with perceived risk of injury. Formal education, the number of children in the home and frequency of paraffin use were positively correlated with knowledge but not with safe practices. The only significant correlate to safe practices was greater income, perhaps a reflection of the impact of financial resources on paraffin safety practices. Conclusion To develop successful paraffin safety interventions, it is necessary to understand baseline levels of knowledge, practice and perceived risk of injury among at-risk populations. Our findings could be of value for designing interventions that will increase knowledge, improve safe practices and lead to the accurate perception of the risk of injury from using paraffin. PMID:19784450

  14. Glucagon Is a Safe and Inexpensive Initial Strategy in Esophageal Food Bolus Impaction.

    PubMed

    Haas, Jason; Leo, Julia; Vakil, Nimish

    2016-03-01

    Controversy exists about the utility of pharmacologic agents and endoscopic technique used for esophageal food bolus impaction. To evaluate the utility of glucagon and the technique used for endoscopic removal, including the rate of success and the adverse events of the techniques. The database of the largest healthcare provider in southeastern Wisconsin was retrospectively reviewed for patients presenting with esophageal food bolus impaction. Data extracted included glucagon administration and its success rate, outcome of radiographic studies, and the endoscopic method of removal and adverse events associated with it, including 30-day mortality. A total of 750 patients were identified with food bolus impaction from 2007 to 2012. Glucagon was administered in 440 patients and was successful in 174 (39.5%). Endoscopic removal was performed in 470 patients and was successful in 469 (99.8%). The push technique was utilized in 209 patients, reduction in the bolus size by piecemeal removal followed by the push technique was utilized in 97 patients, and the pull technique was utilized in 107 patients. There were no perforations with endoscopic removal. Only 4.5% of the X-rays performed reported a possible foreign body within the esophagus. Glucagon was a significantly less-expensive strategy than endoscopic therapy (p < 0.0001). Glucagon is low cost, is moderately effective, and may be considered as an initial strategy. Endoscopic removal regardless of technique is safe and effective. The yield of radiography is poor in the setting of food bolus impaction.

  15. Urinary catheters: history, current status, adverse events and research agenda

    PubMed Central

    Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T.

    2015-01-01

    Abstract For more than 3500 years, urinary catheters have been used to drain the bladder when it fails to empty. For people with impaired bladder function and for whom the method is feasible, clean intermittent self-catheterization is the optimal procedure. For those who require an indwelling catheter, whether short- or long-term, the self-retaining Foley catheter is invariably used, as it has been since its introduction nearly 80 years ago, despite the fact that this catheter can cause bacterial colonization, recurrent and chronic infections, bladder stones and septicaemia, damage to the kidneys, the bladder and the urethra, and contribute to the development of antibiotic resistance. In terms of medical, social and economic resources, the burden of urinary retention and incontinence, aggravated by the use of the Foley catheter, is huge. In the UK, the harm resulting from the use of the Foley catheter costs the National Health Service between £1.0–2.5 billion and accounts for ∼2100 deaths per year. Therefore, there is an urgent need for the development of an alternative indwelling catheter system. The research agenda is for the new catheter to be easy and safe to insert, either urethrally or suprapubically, to be retained reliably in the bladder and to be withdrawn easily and safely when necessary, to mimic natural physiology by filling at low pressure and emptying completely without damage to the bladder, and to have control mechanisms appropriate for all users. PMID:26383168

  16. Solar Disinfection of MODS Mycobacterial Cultures in Resource-Poor Settings

    PubMed Central

    Nathavitharana, Ruvandhi; Coronel, Jorge; Moore, David A. J.

    2007-01-01

    Introduction Safe disposal of TB culture material in which the infectious burden of clinical samples has been greatly amplified is an important challenge in resource-limited settings. The bactericidal capacity of solar cookers has been demonstrated previously for conventional bacteria and contaminated clinical waste. We investigated the use of a simple solar cooker for the sterilization of mycobacterial broth cultures from the microscopic observation drug susceptibility assay (MODS). Methods Simulated TB culture materials were prepared by inoculating 24-well MODS plates with 500 µL of a known concentration of Mycobacterium bovis BCG. In a series of experiments, samples were simultaneously placed inside a box-type solar cooker and control box and removed at timepoints between 15 minutes and 6 hours. Quantitative cultures were performed using retrieved samples to determine sterilization effect. Results All cultures from the control box were positive at or within 1–4 logs of inoculation concentration. Simulated culture plates at concentrations from 103colony-forming-units (CFU)/ml to 107 CFU/ml were completely sterilized after only one hour of cooker exposure, at temperatures between 50–102°C. At 109 CFU/ml (far in excess of diagnostic cultures), it was only possible to recover mycobacterial growth in plates removed after 15 minutes. By 30 minutes all plates were effectively sterilized. Discussion Solar disinfection provides a very effective, safe and low-cost alternative to conventional equipment used for disposal of mycobacterial culture material. Effect of climatic conditions and optimal operating procedure remain to be defined. PMID:17971863

  17. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  18. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  19. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  20. 21 CFR 530.22 - Safe levels and analytical methods for food-producing animals.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... analytical method; or (3) Establish a safe level based on other appropriate scientific, technical, or... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Safe levels and analytical methods for food... § 530.22 Safe levels and analytical methods for food-producing animals. (a) FDA may establish a safe...

  1. A simple design for microwave assisted digestion vessel with low reagent consumption suitable for food and environmental samples

    NASA Astrophysics Data System (ADS)

    Gholami, Mehrdad; Behkami, Shima; Zain, Sharifuddin Md.; Bakirdere, Sezgin

    2016-11-01

    The objective of this work is to prepare a cost-effective, low reagent consumption and high performance polytetrafluoroethylene (PTFE) vessel that is capable to work in domestic microwave for digesting food and environmental samples. The designed vessel has a relatively thicker wall compared to that of commercial vessels. In this design, eight vessels are placed in an acrylonitrile butadiene styrene (ABS) holder to keep them safe and stable. This vessel needs only 2.0 mL of HNO3 and 1.0 mL H2O2 to digest 100 mg of biological sample. The performance of this design is then evaluated with an ICP-MS instrument in the analysis of the several NIST standard reference material of milk 1849a, rice flour 1568b, spinach leave 1570a and Peach Leaves 1547 in a domestic microwave oven with inverter technology. Outstanding agreement to (SRM) values are observed by using the suggested power to time microwave program, which simulates the reflux action occurring in this closed vessel. Taking into account the high cost of commercial microwave vessels and the volume of chemicals needed for various experiments (8-10 mL), this simple vessel is cost effective and suitable for digesting food and environmental samples.

  2. Comparison of manual and automated nucleic acid extraction methods from clinical specimens for microbial diagnosis purposes.

    PubMed

    Wozniak, Aniela; Geoffroy, Enrique; Miranda, Carolina; Castillo, Claudia; Sanhueza, Francia; García, Patricia

    2016-11-01

    The choice of nucleic acids (NAs) extraction method for molecular diagnosis in microbiology is of major importance because of the low microbial load, different nature of microorganisms, and clinical specimens. The NA yield of different extraction methods has been mostly studied using spiked samples. However, information from real human clinical specimens is scarce. The purpose of this study was to compare the performance of a manual low-cost extraction method (Qiagen kit or salting-out extraction method) with the automated high-cost MagNAPure Compact method. According to cycle threshold values for different pathogens, MagNAPure is as efficient as Qiagen for NA extraction from noncomplex clinical specimens (nasopharyngeal swab, skin swab, plasma, respiratory specimens). In contrast, according to cycle threshold values for RNAseP, MagNAPure method may not be an appropriate method for NA extraction from blood. We believe that MagNAPure versatility reduced risk of cross-contamination and reduced hands-on time compensates its high cost. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Power sources for portable electronics and hybrid cars: lithium batteries and fuel cells.

    PubMed

    Scrosati, Bruno

    2005-01-01

    The activities in progress in our laboratory for the development of batteries and fuel cells for portable electronics and hybrid car applications are reviewed and discussed. In the case of lithium batteries, the research has been mainly focused on the characterization of new electrode and electrolyte materials. Results related to disordered carbon anodes and improved, solvent-free, as well as gel-type, polymer electrolytes are particularly stressed. It is shown that the use of proper gel electrolytes, in combination with suitable electrode couples, allows the development of new types of safe, reliable, and low-cost lithium ion batteries which appear to be very promising power sources for hybrid vehicles. Some of the technologies proven to be successful in the lithium battery area are readapted for use in fuel cells. In particular, this approach has been followed for the preparation of low-cost and stable protonic membranes to be proposed as an alternative to the expensive, perfluorosulfonic membranes presently used in polymer electrolyte membrane fuel cells (PEMFCs). Copyright 2005 The Japan Chemical Journal Forum and Wiley Periodicals, Inc

  4. Water-Lubricated Intercalation in V2 O5 ·nH2 O for High-Capacity and High-Rate Aqueous Rechargeable Zinc Batteries.

    PubMed

    Yan, Mengyu; He, Pan; Chen, Ying; Wang, Shanyu; Wei, Qiulong; Zhao, Kangning; Xu, Xu; An, Qinyou; Shuang, Yi; Shao, Yuyan; Mueller, Karl T; Mai, Liqiang; Liu, Jun; Yang, Jihui

    2018-01-01

    Low-cost, environment-friendly aqueous Zn batteries have great potential for large-scale energy storage, but the intercalation of zinc ions in the cathode materials is challenging and complex. Herein, the critical role of structural H 2 O on Zn 2+ intercalation into bilayer V 2 O 5 ·nH 2 O is demonstrated. The results suggest that the H 2 O-solvated Zn 2+ possesses largely reduced effective charge and thus reduced electrostatic interactions with the V 2 O 5 framework, effectively promoting its diffusion. Benefited from the "lubricating" effect, the aqueous Zn battery shows a specific energy of ≈144 Wh kg -1 at 0.3 A g -1 . Meanwhile, it can maintain an energy density of 90 Wh kg -1 at a high power density of 6.4 kW kg -1 (based on the cathode and 200% Zn anode), making it a promising candidate for high-performance, low-cost, safe, and environment-friendly energy-storage devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A Novel Intracranial Pressure Readout Circuit for Passive Wireless LC Sensor.

    PubMed

    Wang, Fa; Zhang, Xuan; Shokoueinejad, Mehdi; Iskandar, Bermans J; Medow, Joshua E; Webster, John G

    2017-10-01

    We present a wide frequency range, low cost, wireless intracranial pressure monitoring system, which includes an implantable passive sensor and an external reader. The passive sensor consists of two spiral coils and transduces the pressure change to a resonant frequency shift. The external portable reader reads out the sensor's resonant frequency over a wide frequency range (35 MHz-2.7 GHz). We propose a novel circuit topology, which tracks the system's impedance and phase change at a high frequency with low-cost components. This circuit is very simple and reliable. A prototype has been developed, and measurement results demonstrate that the device achieves a suitable measurement distance (>2 cm), sufficient sample frequency (>6 Hz), fine resolution, and good measurement accuracy for medical practice. Responsivity of this prototype is 0.92 MHz/mmHg and resolution is 0.028 mmHg. COMSOL specific absorption rate simulation proves that this system is safe. Considerations to improve the device performance have been discussed, which include the size of antenna, the power radiation, the Analog-to-digital converter (ADC) choice, and the signal processing algorithm.

  6. Multi-fidelity methods for uncertainty quantification in transport problems

    NASA Astrophysics Data System (ADS)

    Tartakovsky, G.; Yang, X.; Tartakovsky, A. M.; Barajas-Solano, D. A.; Scheibe, T. D.; Dai, H.; Chen, X.

    2016-12-01

    We compare several multi-fidelity approaches for uncertainty quantification in flow and transport simulations that have a lower computational cost than the standard Monte Carlo method. The cost reduction is achieved by combining a small number of high-resolution (high-fidelity) simulations with a large number of low-resolution (low-fidelity) simulations. We propose a new method, a re-scaled Multi Level Monte Carlo (rMLMC) method. The rMLMC is based on the idea that the statistics of quantities of interest depends on scale/resolution. We compare rMLMC with existing multi-fidelity methods such as Multi Level Monte Carlo (MLMC) and reduced basis methods and discuss advantages of each approach.

  7. A low cost method for hard x-ray grating interferometry.

    PubMed

    Du, Yang; Lei, Yaohu; Liu, Xin; Huang, Jianheng; Zhao, Zhigang; Guo, Jinchuan; Li, Ji; Niu, Hanben

    2016-12-07

    Grating interferometry is advantageous over conventional x-ray absorption imaging because it enables the detection of samples constituted by low atomic number elements (low-Z materials). Therefore, it has a potential application in biological science and medical diagnostics. The grating interferometry has some critical optics components such as absorption gratings which are conventionally manufactured by the lithography, electroplating, and molding (LIGA) technique and employing gold as the absorbent material in it. However, great challenge lies in its implementations for practical applications because of the cost and difficulty to achieve high aspect ratio absorbing grating devices. In this paper, we present a low-cost approach that involves using the micro-casting technique with bismuth (Bi) as the absorber in source grating and as well as filling cesium iodide thallium(CsI:Tl) in a periodically structured scintillator. No costly facilities as synchrotron radiation are required and cheap material is used in our approach. Our experiment using these components shows high quality complementary images can be obtained with contrast of absorption, phase and visibility. This alternative method conquers the limitation of costly grating devices for a long time and stands an important step towards the further practical application of grating interferometry.

  8. Taguchi Approach to Design Optimization for Quality and Cost: An Overview

    NASA Technical Reports Server (NTRS)

    Unal, Resit; Dean, Edwin B.

    1990-01-01

    Calibrations to existing cost of doing business in space indicate that to establish human presence on the Moon and Mars with the Space Exploration Initiative (SEI) will require resources, felt by many, to be more than the national budget can afford. In order for SEI to succeed, we must actually design and build space systems at lower cost this time, even with tremendous increases in quality and performance requirements, such as extremely high reliability. This implies that both government and industry must change the way they do business. Therefore, new philosophy and technology must be employed to design and produce reliable, high quality space systems at low cost. In recognizing the need to reduce cost and improve quality and productivity, Department of Defense (DoD) and National Aeronautics and Space Administration (NASA) have initiated Total Quality Management (TQM). TQM is a revolutionary management strategy in quality assurance and cost reduction. TQM requires complete management commitment, employee involvement, and use of statistical tools. The quality engineering methods of Dr. Taguchi, employing design of experiments (DOE), is one of the most important statistical tools of TQM for designing high quality systems at reduced cost. Taguchi methods provide an efficient and systematic way to optimize designs for performance, quality, and cost. Taguchi methods have been used successfully in Japan and the United States in designing reliable, high quality products at low cost in such areas as automobiles and consumer electronics. However, these methods are just beginning to see application in the aerospace industry. The purpose of this paper is to present an overview of the Taguchi methods for improving quality and reducing cost, describe the current state of applications and its role in identifying cost sensitive design parameters.

  9. Cost and Performance Report - Evaluating the Longevity and Hydraulic Performance of Permeable Reactive Barriers at Department of Defense Sites

    DTIC Science & Technology

    2002-12-01

    methods, such as jetting, hydraulic fracturing , and vibratory beam, have been demonstrated at some sites, as they offer some cost advantages at deep sites...while still keeping the implementation cost relatively low. Beyond these depths, innovative methods (such as jetting and hydraulic fracturing ) can...type excavator and a trench-type barrier. For sites where the affected aquifer is deeper, innovative methods, such as jetting and hydraulic

  10. Low-cost photonic sensors for carbon dioxide exchange rate measurement

    NASA Astrophysics Data System (ADS)

    Bieda, Marcin S.; Sobotka, Piotr; Lesiak, Piotr; Woliński, Tomasz R.

    2017-10-01

    Carbon dioxide (CO2) measurement has an important role in atmosphere monitoring. Usually, two types of measurements are carried out. The first one is based on gas concentration measurement while the second involves gas exchange rate measurement between earth surface and atmosphere [1]. There are several methods which allow gas concentration measurement. However, most of them require expensive instrumentation or large devices (i.e. gas chambers). In order to precisely measure either CO2 concentration or CO2 exchange rate, preferably a sensors network should be used. These sensors must have small dimensions, low power consumption, and they should be cost-effective. Therefore, this creates a great demand for a robust low-power and low-cost CO2 sensor [2,3]. As a solution, we propose a photonic sensor that can measure CO2 concentration and also can be used to measure gas exchange by using the Eddy covariance method [1].

  11. Cost Effective Recovery of Low-TDS Frac Flowback Water for Re-use

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Claire Henderson; Harish Acharya; Hope Matis

    2011-03-31

    The project goal was to develop a cost-effective water recovery process to reduce the costs and envi-ronmental impact of shale gas production. This effort sought to develop both a flowback water pre-treatment process and a membrane-based partial demineralization process for the treatment of the low-Total Dissolved Solids (TDS) portion of the flowback water produced during hydrofracturing operations. The TDS cutoff for consideration in this project is < 35,000 {approx} 45,000 ppm, which is the typical limit for economic water recovery employing reverse osmosis (RO) type membrane desalination processes. The ultimate objective is the production of clean, reclaimed water suitable formore » re-use in hydrofracturing operations. The team successfully compiled data on flowback composition and other attributes across multiple shale plays, identified the likely applicability of membrane treatment processes in those shales, and expanded the proposed product portfolio to include four options suitable for various reuse or discharge applications. Pretreatment technologies were evaluated at the lab scale and down-selected based upon their efficacy in removing key contaminants. The chosen technologies were further validated by performing membrane fouling studies with treated flowback water to demonstrate the technical feasibility of flowback treatment with RO membranes. Process flow schemes were constructed for each of the four product options based on experimental performance data from actual flowback water treatment studies. For the products requiring membrane treatment, membrane system model-ing software was used to create designs for enhanced water recovery beyond the typical seawater desalination benchmark. System costs based upon vendor and internal cost information for all process flow schemes were generated and are below target and in line with customer expectations. Finally, to account for temporal and geographic variability in flowback characteristics as well as local disposal costs and regulations, a parametric value assessment tool was created to assess the economic attractiveness of a given flowback recovery process relative to conventional disposal for any combination of anticipated flowback TDS and local disposal cost. It is concluded that membrane systems in combination with appropriate pretreatment technologies can provide cost-effective recovery of low-TDS flow-back water for either beneficial reuse or safe surface discharge.« less

  12. An accurate cost effective DFT approach to study the sensing behaviour of polypyrrole towards nitrate ions in gas and aqueous phases.

    PubMed

    Wasim, Fatima; Mahmood, Tariq; Ayub, Khurshid

    2016-07-28

    Density functional theory (DFT) calculations have been performed to study the response of polypyrrole towards nitrate ions in gas and aqueous phases. First, an accurate estimate of interaction energies is obtained by methods calibrated against the gold standard CCSD(T) method. Then, a number of low cost DFT methods are also evaluated for their ability to accurately estimate the binding energies of polymer-nitrate complexes. The low cost methods evaluated here include dispersion corrected potential (DCP), Grimme's D3 correction, counterpoise correction of the B3LYP method, and Minnesota functionals (M05-2X). The interaction energies calculated using the counterpoise (CP) correction and DCP methods at the B3LYP level are in better agreement with the interaction energies calculated using the calibrated methods. The interaction energies of an infinite polymer (polypyrrole) with nitrate ions are calculated by a variety of low cost methods in order to find the associated errors. The electronic and spectroscopic properties of polypyrrole oligomers nPy (where n = 1-9) and nPy-NO3(-) complexes are calculated, and then extrapolated for an infinite polymer through a second degree polynomial fit. Charge analysis, frontier molecular orbital (FMO) analysis and density of state studies also reveal the sensing ability of polypyrrole towards nitrate ions. Interaction energies, charge analysis and density of states analyses illustrate that the response of polypyrrole towards nitrate ions is considerably reduced in the aqueous medium (compared to the gas phase).

  13. Cost Analysis of Endovascular versus Open Repair in the Treatment of Thoracic Aortic Aneurysms

    PubMed Central

    Gillen, Jacob R.; Schaheen, Basil W.; Yount, Kenan W.; Cherry, Kenneth J.; Kern, John A.; Kron, Irving L.; Upchurch, Gilbert R.; Lau, Christine L.

    2014-01-01

    Objective For descending thoracic aortic aneurysms (TAAs), it is generally considered that endovascular stents (TEVARs) reduce operative morbidity and mortality compared to open surgical repair. However, long-term differences in patient survival have not been demonstrated, and an increased need for aortic reintervention has been observed. Many assume that TEVAR becomes less cost effective through time due to higher rates of reintervention and surveillance imaging. This study investigated mid-term outcomes and hospital costs of TEVAR compared with open TAA repair. Methods This was a retrospective, single institution review of elective thoracic aortic aneurysm repairs between 2005 and 2012. Patient demographics, operative outcomes, reintervention rates, and hospital costs were assessed. The literature was also reviewed to determine commonly observed complication and reintervention rates for TEVAR and open repair. Monte Carlo simulation was utilized to model and forecast hospital costs for TEVAR and open TAA repair up to 3 years post-intervention. Results Our cohort consisted of 131 TEVARs and 27 open repairs. TEVAR patients were significantly older (67.2 vs. 58.7, p=0.02) and trended towards a more severe comorbidity profile. Operative mortality for TEVAR and open repair was 5.3% and 3.7%, respectively (p=1.0). There was a trend towards more complications in the TEVAR group, although not statistically significant (all p>0.05). In-hospital costs were significantly greater in the TEVAR group ($52,008 vs. $37,172, p=0.001). However, cost modeling utilizing reported complication and reintervention rates from the literature overlaid with our cost data produced a higher cost for the open group in-hospital ($55,109 vs. $48,006) and at 3 years ($58,426 vs. $52,825). Interestingly, TEVAR hospital costs, not reintervention rates, were the most significant driver of cost in the TEVAR group. Conclusions Our institutional data showed a trend toward lower mortality and complication rates with open TAA repair, with significantly lower costs within this cohort compared to TEVAR. These findings were likely at least in part due to the milder comorbidity profile within these patients. In contrast, cost modeling using Monte Carlo simulation demonstrated lower costs with TEVAR compared to open repair at all time points up to 3 years post-intervention. Our institutional data shows that with appropriate patient selection, open repair can be performed safely with low complication rates comparable to TEVAR. The cost model argues that despite the costs associated with more frequent surveillance imaging and reinterventions, TEVAR remains the more cost effective option even years after TAA repair. PMID:25449008

  14. Investigation of low-cost ablative heat shield fabrication for space shuttles

    NASA Technical Reports Server (NTRS)

    Chandler, H. H.

    1972-01-01

    Improvements in the processes and design to reduce the manufacturing costs for low density ablative panels for the space shuttle are discussed. The areas that were studied included methods of loading honeycomb core, alternative reinforcement concepts, and the use of reusable subpanels. A review of previous studies on the fabrication of low-cost ablative panels and on permissible defects that do not affect thermal performance was conducted. Considerable differences in the quoted prices for ablative panels, even though the various contractors had reported similar fabrication times were discovered. How these cost differences arise from different estimating criteria and which estimating assumptions and other costs must be included in order to arrive at a realistic price are discussed.

  15. ESMO International Consortium Study on the availability, out-of-pocket costs and accessibility of antineoplastic medicines in countries outside of Europe.

    PubMed

    Cherny, N I; Sullivan, R; Torode, J; Saar, M; Eniu, A

    2017-11-01

    The availability and affordability of safe, effective, high-quality, affordable anticancer therapies are a core requirement for effective national cancer control plans. Online survey based on a previously validated approach. The aims of the study were to evaluate (i) the availability on national formulary of licensed antineoplastic medicines across the globe, (ii) patient out-of-pocket costs for the medications, (iii) the actual availability of the medication for a patient with a valid prescription, (iv) information relating to possible factors adversely impacting the availability of antineoplastic agents and (v) the impact of the country's level of economic development on these parameters. A total of 304 field reporters from 97 countries were invited to participate. The preliminary set of data was posted on the ESMO website for open peer review and amendments have been incorporated into the final report. Surveys were submitted by 135 reporters from 63 countries and additional peer-review data were submitted by 54 reporters from 19 countries. There are substantial differences in the formulary availability, out-of-pocket costs and actual availability for many anticancer medicines. The most substantial issues are in lower-middle- and low-income countries. Even among medications on the WHO Model List of Essential Medicines (EML) the discrepancies are profound and these relate to high out-of-pocket costs (in low-middle-income countries 32.0% of EML medicines are available only at full cost and 5.2% are not available at all, and for low-income countries, the corresponding figures are even worse at 57.7% and 8.3%, respectively). There is wide global variation in formulary availability, out-of-pocket expenditures and actual availability for most licensed anticancer medicines. Low- and low-middle-income countries have significant lack of availability and high out-of-pocket expenditures for cancer medicines on the WHO EML, with much less availability of new, more expensive targeted agents compared with high-income countries. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology.

  16. Enhanced fluoride adsorption by nano crystalline γ-alumina: adsorption kinetics, isotherm modeling and thermodynamic studies

    NASA Astrophysics Data System (ADS)

    Chinnakoti, Prathibha; Chunduri, Avinash L. A.; Vankayala, Ranganayakulu K.; Patnaik, Sandeep; Kamisetti, Venkataramaniah

    2017-09-01

    Nano materials in particular nano oxides with enhanced surface area and an excellent catalytic surface serve as potential adsorbents for defluoridation of water. In the present study nano γ-alumina was synthesized through a simple and low cost, surfactant assisted solution combustion method. As synthesized material was characterized by XRD and FESEM for its phase, size and morphological characteristics. Surface properties have been investigated by BET method. Nano γ-alumina was further used for a detailed adsorption study to remove fluoride from water. Batches of experiments were performed at various experimental conditions such as solution pH, adsorbent dose, initial fluoride concentration and contact time to test the defluoridation ability of γ-alumina. Fluoride Adsorption by nano sized γ-alumina was rapid and reached equilibrium within two hours. The adsorption worked well at pH 4.0, where ˜96 % of fluoride was found to be adsorbed on adsorbent. It was possible to reduce fluoride levels to as low as 0.3 mg/L (within the safe limit of WHO: ≤1.5 mg/L) from an initial fluoride levels of 10 mg/L. This could be achieved using a very small quantity, 1 g/L of γ-alumina at pH 4 within 1 h of contact time. Defluoridation capacity of nano γ-alumina was further investigated by fitting the equilibrium data to various isotherm as well as kinetic models. The present study revealed that γ-alumina could be an efficient adsorbent for treating fluoride contaminated water.

  17. Using ATP-driven bioluminescence assay to monitor microbial safety in a contemporary human cadaver laboratory.

    PubMed

    Benninger, Brion; Maier, Thomas

    2015-03-01

    The objective of this study was to utilize a cost-effective method for assessing the levels of bacterial, yeast, and mold activity during a human dissection laboratory course. Nowadays, compliance with safety regulations is policed by institutions at higher standards than ever before. Fear of acquiring an unknown infection is one of the top concerns of professional healthcare students, and it provokes anti-laboratory anxiety. Human cadavers are not routinely tested for bacteria and viruses prior to embalming. Human anatomy dissecting rooms that house embalmed cadavers are normally cleaned after the dissected cadavers have been removed. There is no evidence that investigators have ever assessed bacterial and fungal activities using adenosine triphosphate (ATP)-driven bioluminescence assays. A literature search was conducted on texts, journals, and websites regarding bacterial, yeast, and mold activities in an active cadaver laboratory. Midway into a clinical anatomy course, ATP bioluminescence assays were used to swab various sites within the dissection room, including entrance and exiting door handles, water taps, cadaver tables, counter tops, imaging material, X-ray box switches, and the cadaver surfaces. The results demonstrated very low activities on cadaver tables, washing up areas, and exiting door handles. There was low activity on counter tops and X-ray boxes. There was medium activity on the entrance door handles. These findings suggest an inexpensive and accurate method for monitoring safety compliance and microbial activity. Students can feel confident and safe in the environment in which they work. © 2014 Wiley Periodicals, Inc.

  18. Facilitators and Barriers to Safe Medication Administration to Hospital Inpatients: A Mixed Methods Study of Nurses’ Medication Administration Processes and Systems (the MAPS Study)

    PubMed Central

    McLeod, Monsey; Barber, Nicholas; Franklin, Bryony Dean

    2015-01-01

    Context Research has documented the problem of medication administration errors and their causes. However, little is known about how nurses administer medications safely or how existing systems facilitate or hinder medication administration; this represents a missed opportunity for implementation of practical, effective, and low-cost strategies to increase safety. Aim To identify system factors that facilitate and/or hinder successful medication administration focused on three inter-related areas: nurse practices and workarounds, workflow, and interruptions and distractions. Methods We used a mixed-methods ethnographic approach involving observational fieldwork, field notes, participant narratives, photographs, and spaghetti diagrams to identify system factors that facilitate and/or hinder successful medication administration in three inpatient wards, each from a different English NHS trust. We supplemented this with quantitative data on interruptions and distractions among other established medication safety measures. Findings Overall, 43 nurses on 56 drug rounds were observed. We identified a median of 5.5 interruptions and 9.6 distractions per hour. We identified three interlinked themes that facilitated successful medication administration in some situations but which also acted as barriers in others: (1) system configurations and features, (2) behaviour types among nurses, and (3) patient interactions. Some system configurations and features acted as a physical constraint for parts of the drug round, however some system effects were partly dependent on nurses’ inherent behaviour; we grouped these behaviours into ‘task focused’, and ‘patient-interaction focused’. The former contributed to a more streamlined workflow with fewer interruptions while the latter seemed to empower patients to act as a defence barrier against medication errors by being: (1) an active resource of information, (2) a passive information resource, and/or (3) a ‘double-checker’. Conclusions We have identified practical examples of system effects on work optimisation and nurse behaviours that potentially increase medication safety, and conceptualized ways in which patient involvement can increase medication safety in hospitals. PMID:26098106

  19. Turkey's High Temperature Geothermal Energy Resources and Electricity Production Potential

    NASA Astrophysics Data System (ADS)

    Bilgin, Ö.

    2012-04-01

    Turkey is in the first 7 countries in the world in terms of potential and applications. Geothermal energy which is an alternative energy resource has advantages such as low-cost, clean, safe and natural resource. Geothermal energy is defined as hot water and steam which is formed by heat that accumulated in various depths of the Earth's crust; with more than 20oC temperature and which contain more than fused minerals, various salts and gases than normal underground and ground water. It is divided into three groups as low, medium and high temperature. High-temperature fluid is used in electricity generation, low and medium temperature fluids are used in greenhouses, houses, airport runways, animal farms and places such as swimming pools heating. In this study high temperature geothermal fields in Turkey which is suitable for electricity production, properties and electricity production potential was investigated.

  20. Full Body Loading for Small Exercise Devices Project

    NASA Technical Reports Server (NTRS)

    Downs, Meghan; Hanson, Andrea; Newby, Nathaniel

    2015-01-01

    Protecting astronauts' spine, hip, and lower body musculoskeletal strength will be critical to safely and efficiently perform physically demanding vehicle egress, exploration, and habitat building activities necessary to expand human presence in the solar system. Functionally limiting decrements in musculoskeletal health are likely during Mars proving-ground and Earth-independent missions given extended transit times and the vehicle limitations for exercise devices (low-mass, small volume). Most small exercise device concepts are designed with single-cable loading, which inhibits the ability to perform full body exercises requiring two-point loading at the shoulders. Shoulder loading is critical to protect spine, hip, and lower body musculoskeletal strength. We propose a novel low-mass, low-maintenance, and rapid deploy pulley-based system that can attach to a single-cable small exercise device to enable two-point loading at the shoulders. This attachment could protect astronauts' health and save cost, space, and energy during all phases of the Journey to Mars.

Top