Space Fission Propulsion Testing and Development Progress. Phase 1
NASA Technical Reports Server (NTRS)
VanDyke, Melissa; Houts, Mike; Pedersen, Kevin; Godfroy, Tom; Dickens, Ricky; Poston, David; Reid, Bob; Salvail, Pat; Ring, Peter; Rodgers, Stephen L. (Technical Monitor)
2001-01-01
Successful development of space fission systems will require an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. Testing can be divided into two categories, non-nuclear tests and nuclear tests. Full power nuclear tests of space fission systems we expensive, time consuming, and of limited use, even in the best of programmatic environments. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. Non-nuclear tests are affordable and timely, and the cause of component and system failures can be quickly and accurately identified. MSFC is leading a Safe Affordable Fission Engine (SAFE) test series whose ultimate goal is the demonstration of a 300 kW flight configuration system using non-nuclear testing. This test series is carried out in collaboration with other NASA centers, other government agencies, industry, and universities. If SAFE-related nuclear tests are desired they will have a high probability of success and can be performed at existing nuclear facilities. The paper describes the SAFE non-nuclear test series, which includes test article descriptions, test results and conclusions, and future test plans.
Phase 1 space fission propulsion system testing and development progress
NASA Astrophysics Data System (ADS)
van Dyke, Melissa; Houts, Mike; Pedersen, Kevin; Godfroy, Tom; Dickens, Ricky; Poston, David; Reid, Bob; Salvail, Pat; Ring, Peter
2001-02-01
Successful development of space fission systems will require an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. Testing can be divided into two categories, non-nuclear tests and nuclear tests. Full power nuclear tests of space fission systems are expensive, time consuming, and of limited use, even in the best of programmatic environments. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. Non-nuclear tests are affordable and timely, and the cause of component and system failures can be quickly and accurately identified, MSFC is leading a Safe Affordable Fission Engine (SAFE) test series whose ultimate goal is the demonstration of a 300 kW flight configuration system using non-nuclear testing. This test series is carried out in collaboration with other NASA centers, other government agencies, industry, and universities. If SAFE-related nuclear tests are desired, they will have a high probability of success and can be performed at existing nuclear facilities. The paper describes the SAFE non-nuclear test series, which includes test article descriptions, test results and conclusions, and future test plans. .
NASA Technical Reports Server (NTRS)
Hrbud, Ivana; VanDyke, Melissa; Houts, Mike; Goodfellow, Keith; Schafer, Charles (Technical Monitor)
2001-01-01
The Safe Affordable Fission Engine (SAFE) test series addresses Phase 1 Space Fission Systems issues in particular non-nuclear testing and system integration issues leading to the testing and non-nuclear demonstration of a 400-kW fully integrated flight unit. The first part of the SAFE 30 test series demonstrated operation of the simulated nuclear core and heat pipe system. Experimental data acquired in a number of different test scenarios will validate existing computational models, demonstrated system flexibility (fast start-ups, multiple start-ups/shut downs), simulate predictable failure modes and operating environments. The objective of the second part is to demonstrate an integrated propulsion system consisting of a core, conversion system and a thruster where the system converts thermal heat into jet power. This end-to-end system demonstration sets a precedent for ground testing of nuclear electric propulsion systems. The paper describes the SAFE 30 end-to-end system demonstration and its subsystems.
First Generation Least Expensive Approach to Fission (FiGLEAF) Testing Results
NASA Technical Reports Server (NTRS)
VanDyke, Melissa; Houts, Mike; Pedersen, Kevin; Godfroy, Tom; Dickens, Ricky; Poston, David; Reid, Bob; Salvail. Pat; Ring, Peter; Schmidt, George R. (Technical Monitor)
2000-01-01
Successful development of space fission systems will require an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. Testing can be divided into two categories, non-nuclear tests and nuclear tests. Full power nuclear tests of space fission systems are expensive, time consuming, and of limited use, even in the best of programmatic environments. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. Non-nuclear tests are affordable and timely, and the cause of component and system failures can be quickly and accurately identified. MSFC is leading a Safe Affordable Fission Engine (SAFE) test series whose ultimate goal is the demonstration of a 300 kW flight configuration system using non-nuclear testing. This test series is carried out in collaboration with other NASA centers, other government agencies, industry, and universities. The paper describes the SAFE test series, which includes test article descriptions, test results and conclusions, and future test plans.
An End-To-End Test of A Simulated Nuclear Electric Propulsion System
NASA Technical Reports Server (NTRS)
VanDyke, Melissa; Hrbud, Ivana; Goddfellow, Keith; Rodgers, Stephen L. (Technical Monitor)
2002-01-01
The Safe Affordable Fission Engine (SAFE) test series addresses Phase I Space Fission Systems issues in it particular non-nuclear testing and system integration issues leading to the testing and non-nuclear demonstration of a 400-kW fully integrated flight unit. The first part of the SAFE 30 test series demonstrated operation of the simulated nuclear core and heat pipe system. Experimental data acquired in a number of different test scenarios will validate existing computational models, demonstrated system flexibility (fast start-ups, multiple start-ups/shut downs), simulate predictable failure modes and operating environments. The objective of the second part is to demonstrate an integrated propulsion system consisting of a core, conversion system and a thruster where the system converts thermal heat into jet power. This end-to-end system demonstration sets a precedent for ground testing of nuclear electric propulsion systems. The paper describes the SAFE 30 end-to-end system demonstration and its subsystems.
Phase 1 Space Fission Propulsion System Testing and Development Progress
NASA Technical Reports Server (NTRS)
VanDyke, Melissa; Houts, Mike; Godfroy, Tom; Dickens, Ricky; Poston, David; Kapernick, Rick; Reid, Bob; Salvail, Pat; Ring, Peter; Schafer, Charles (Technical Monitor)
2001-01-01
Successful development of space fission systems requires an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. The Safe Affordable Fission Engine (SAFE) test series, whose ultimate goal is the demonstration of a 300 kW flight configuration system, has demonstrated that realistic testing can be performed using non-nuclear methods. This test series, carried out in collaboration with other NASA centers, other government agencies, industry, and universities, successfully completed a testing program with a 30 kWt core, Stirling engine, and ion engine configuration. Additionally, a 100 kWt core is in fabrication and appropriate test facilities are being reconfigured. This paper describes the current SAFE non-nuclear tests, which includes test article descriptions, test results and conclusions, and future test plans.
DOT National Transportation Integrated Search
2012-05-01
A total of 486 transportation employees employed by a major railroad completed a series of : tests constructed for this project. These tests or instruments included the Denver Lifestyle : Questionnaire, a performance rating scale called the Employees...
What's Happening on the School Bus Performance Front?
ERIC Educational Resources Information Center
Combs, Hanford L.
The most urgent order of business in the national scene is to complete the development of a series of new performance tests for school bus bodies and chassis to establish a benchmark for safe construction that can be verified by independent testing agencies. Such performance tests should incorporate the new Federal Joint Strength Efficiency…
Drug Testing. ERIC Digest Series Number EA 35.
ERIC Educational Resources Information Center
Klauke, Amy
The issue of drug testing is the focus of this ERIC Digest. Several aspects of drug testing discussed in question-and-answer format: (1) What is the current status of drug use in the schools? (2) What legal questions arise when schools consider drug testing? (3) How might drug testing be applied in a fair, economical, and legally safe manner? (4)…
Development of Lidar Sensor Systems for Autonomous Safe Landing on Planetary Bodies
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin; Pierottet, Diego F.; Petway, Larry B.; Vanek, Michael D.
2010-01-01
Lidar has been identified by NASA as a key technology for enabling autonomous safe landing of future robotic and crewed lunar landing vehicles. NASA LaRC has been developing three laser/lidar sensor systems under the ALHAT project. The capabilities of these Lidar sensor systems were evaluated through a series of static tests using a calibrated target and through dynamic tests aboard helicopters and a fixed wing aircraft. The airborne tests were performed over Moon-like terrain in the California and Nevada deserts. These tests provided the necessary data for the development of signal processing software, and algorithms for hazard detection and navigation. The tests helped identify technology areas needing improvement and will also help guide future technology advancement activities.
Evolution of the Hubble Space Telescope Safing Systems
NASA Technical Reports Server (NTRS)
Pepe, Joyce; Myslinski, Michael
2006-01-01
The Hubble Space Telescope (HST) was launched on April 24 1990, with an expected lifespan of 15 years. Central to the spacecraft design was the concept of a series of on-orbit shuttle servicing missions permitting astronauts to replace failed equipment, update the scientific instruments and keep the HST at the forefront of astronomical discoveries. One key to the success of the Hubble mission has been the robust Safing systems designed to monitor the performance of the observatory and to react to keep the spacecraft safe in the event of equipment anomaly. The spacecraft Safing System consists of a range of software tests in the primary flight computer that evaluate the performance of mission critical hardware, safe modes that are activated when the primary control mode is deemed inadequate for protecting the vehicle, and special actions that the computer can take to autonomously reconfigure critical hardware. The HST Safing System was structured to autonomously detect electrical power system, data management system, and pointing control system malfunctions and to configure the vehicle to ensure safe operation without ground intervention for up to 72 hours. There is also a dedicated safe mode computer that constantly monitors a keep-alive signal from the primary computer. If this signal stops, the safe mode computer shuts down the primary computer and takes over control of the vehicle, putting it into a safe, low-power configuration. The HST Safing system has continued to evolve as equipment has aged, as new hardware has been installed on the vehicle, and as the operation modes have matured during the mission. Along with the continual refinement of the limits used in the safing tests, several new tests have been added to the monitoring system, and new safe modes have been added to the flight software. This paper will focus on the evolution of the HST Safing System and Safing tests, and the importance of this evolution to prolonging the science operations of the telescope.
Utilization of 3D imaging flash lidar technology for autonomous safe landing on planetary bodies
NASA Astrophysics Data System (ADS)
Amzajerdian, Farzin; Vanek, Michael; Petway, Larry; Pierrottet, Diego; Busch, George; Bulyshev, Alexander
2010-01-01
NASA considers Flash Lidar a critical technology for enabling autonomous safe landing of future large robotic and crewed vehicles on the surface of the Moon and Mars. Flash Lidar can generate 3-Dimensional images of the terrain to identify hazardous features such as craters, rocks, and steep slopes during the final stages of descent and landing. The onboard flight comptuer can use the 3-D map of terain to guide the vehicle to a safe site. The capabilities of Flash Lidar technology were evaluated through a series of static tests using a calibrated target and through dynamic tests aboard a helicopter and a fixed wing airctarft. The aircraft flight tests were perfomed over Moonlike terrain in the California and Nevada deserts. This paper briefly describes the Flash Lidar static and aircraft flight test results. These test results are analyzed against the landing application requirements to identify the areas of technology improvement. The ongoing technology advancement activities are then explained and their goals are described.
Utilization of 3-D Imaging Flash Lidar Technology for Autonomous Safe Landing on Planetary Bodies
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin; Vanek, Michael; Petway, Larry; Pierrotter, Diego; Busch, George; Bulyshev, Alexander
2010-01-01
NASA considers Flash Lidar a critical technology for enabling autonomous safe landing of future large robotic and crewed vehicles on the surface of the Moon and Mars. Flash Lidar can generate 3-Dimensional images of the terrain to identify hazardous features such as craters, rocks, and steep slopes during the final stages of descent and landing. The onboard flight computer can use the 3-D map of terrain to guide the vehicle to a safe site. The capabilities of Flash Lidar technology were evaluated through a series of static tests using a calibrated target and through dynamic tests aboard a helicopter and a fixed wing aircraft. The aircraft flight tests were performed over Moon-like terrain in the California and Nevada deserts. This paper briefly describes the Flash Lidar static and aircraft flight test results. These test results are analyzed against the landing application requirements to identify the areas of technology improvement. The ongoing technology advancement activities are then explained and their goals are described.
NETGEAR ProSAFE M4300 Series 10-GbE Switch Tutorial
2016-11-01
ARL-TN-0803 ● NOV 2016 US Army Research Laboratory NETGEAR ProSAFE M4300 Series 10-GbE Switch Tutorial by Benjamin Kenawell...Disclaimers The findings in this report are not to be construed as an official Department of the Army position unless so designated by other...NETGEAR ProSAFE M4300 Series 10-GbE Switch Tutorial by Benjamin Kenawell Science and Engineering Apprentice Program (SEAP), Adelphi, MD Brian
EMPFASIS: A Publication of the National Electronics Manufacturing Center of Excellence
2010-01-01
for moisture, salt spray, and wind driven rain protection. • Conversion to ruggedized electrical and fluid connectors. • Additional circuitry, if...computer control technology, designed for safe lead free and eutectic rework applications. Available in two models, the RD-500 series features a three-stage...shock, Temperature Humidity Bias (THB) Testing, Highly Accelerated Stress Testing (HAST), salt fog, high temperature storage, or other environmental
Safe corridors for K-wiring in phalangeal fractures.
Rex, C; Vignesh, R; Javed, M; Balaji, Subba Chandra; Premanand, C; Zakki, Syed Ashfaque
2015-01-01
Unstable phalangeal fractures are commonly treated with K-wire fixation. Operative fixation must be used judiciously and with the expectation that the ultimate outcome should be better than the outcome after nonoperative management. It is necessary to achieve a stable fracture fixation and early mobilization. In order to achieve this goal, one should closely understand the safe portals/corridors in hand for K-wire entry for fractures of the phalanges. Safe corridors were defined and tested using a pilot cadaveric and a clinical case study by assessing the outcome. In our prospective case series, 50 patients with 64 phalangeal fractures were treated with closed reduction and K-wires were inserted through safe portals identified by a pilot cadaveric study. On table active finger movement test was done and the results were analyed using radiology, disabilities of the arm, shoulder, and hand (DASH) score and total active motion (TAM). In our study, little finger (n = 28) was the most commonly involved digit. In fracture pattern, transverse (n = 20) and spiral (n = 20) types were common. Proximal phalanx (n = 38) was commonly involved and the common site being the base of the phalanx (n = 28). 47 (95%) patients had excellent TAM and the mean postoperative DASH score was 58.05. All patients achieved excellent and good scores proving the importance of the safe corridor concept. K-wiring through the safe corridor has proved to yield the best clinical results because of least tethering of soft tissues as evidenced by performing "on-table active finger movement test" at the time of surgery. We strongly recommend K-wiring through safe portals in all phalangeal fractures.
Orbiter wheel and tire certification
NASA Technical Reports Server (NTRS)
Campbell, C. C., Jr.
1985-01-01
The orbiter wheel and tire development has required a unique series of certification tests to demonstrate the ability of the hardware to meet severe performance requirements. Early tests of the main landing gear wheel using conventional slow roll testing resulted in hardware failures. This resulted in a need to conduct high velocity tests with crosswind effects for assurance that the hardware was safe for a limited number of flights. Currently, this approach and the conventional slow roll and static tests are used to certify the wheel/tire assembly for operational use.
Ethylhexylglycerin: a low-risk, but highly relevant, sensitizer in 'hypo-allergenic' cosmetics.
Aerts, Olivier; Verhulst, Lien; Goossens, An
2016-05-01
Ethylhexylglycerin is a relatively new cosmetic ingredient that is used for its surfactant, emollient, skin-conditioning and antimicrobial properties. Since 2002, it has been occasionally reported as a contact allergen. To report on 13 patients who presented with allergic contact dermatitis caused by ethylhexylglycerin, evaluated at two Belgian university patch test clinics during the period 1990-2015. The patients were patch tested with the European baseline series, a cosmetic series, and - if indicated - additional series. Both the cosmetic products used and their single ingredients were patch tested. All but one of the ethylhexylglycerin-allergic patients were female, with a median age of 43 years (range: 29-81 years), most often suffering from dermatitis on the face, and sometimes on the hands and/or axillae. As the culprit products, leave-on cosmetics were identified, including a high number of proclaimed 'hypo-allergenic' and 'preservative-free' facial creams, sun protection creams, and deodorants. Ethylhexylglycerin is a rare, but highly relevant, cosmetic sensitizer, even in those products advertised to be safe for consumers. Targeted patch testing with ethylhexylglycerin 5% pet. is very useful, and routine patch testing in a cosmetic series may be considered. Higher test concentrations might be indicated in selected cases. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Bull, John; Mah, Robert; Davis, Gloria; Conley, Joe; Hardy, Gordon; Gibson, Jim; Blake, Matthew; Bryant, Don; Williams, Diane
1995-01-01
Failures of aircraft primary flight-control systems to aircraft during flight have led to catastrophic accidents with subsequent loss of lives (e.g. , DC-1O crash, B-747 crash, C-5 crash, B-52 crash, and others). Dryden Flight Research Center (DFRC) investigated the use of engine thrust for emergency flight control of several airplanes, including the B-720, Lear 24, F-15, C-402, and B-747. A series of three piloted simulation tests have been conducted at Ames Research Center to investigate propulsion control for safely landing a medium size jet transport which has experienced a total primary flight-control failure. The first series of tests was completed in July 1992 and defined the best interface for the pilot commands to drive the engines. The second series of tests was completed in August 1994 and investigated propulsion controlled aircraft (PCA) display requirements and various command modes. The third series of tests was completed in May 1995 and investigated PCA full-flight envelope capabilities. This report describes the concept of a PCA, discusses pilot controls, displays, and procedures; and presents the results of piloted simulation evaluations of the concept by a cross-section of air transport pilots.
Apollo experience report: Manned thermal-vacuum testing of spacecraft
NASA Technical Reports Server (NTRS)
Mclane, J. C., Jr.
1974-01-01
Manned thermal-vacuum tests of the Apollo spacecraft presented many first-time problems in the areas of test philosophy, operational concepts, and program implementation. The rationale used to resolve these problems is explained and examined critically in view of actual experience. The series of 12 tests involving 1517 hours of chamber operating time resulted in the disclosure of numerous equipment and procedural deficiencies of significance to the flight mission. Test experience and results in view of subsequent flight experience confirmed that thermal-vacuum testing of integrated manned spacecraft provides a feasible, cost-effective, and safe technique with which to obtain maximum confidence in spacecraft flight worthiness early in the program.
2003-12-01
This photo gives an overhead look at an RS-88 development rocket engine being test fired at NASA's Marshall Space Flight Center in Huntsville, Alabama, in support of the Pad Abort Demonstration (PAD) test flights for NASA's Orbital Space Plane (OSP). The tests could be instrumental in developing the first crew launch escape system in almost 30 years. Paving the way for a series of integrated PAD test flights, the engine tests support development of a system that could pull a crew safely away from danger during liftoff. A series of 16 hot fire tests of a 50,000-pound thrust RS-88 rocket engine were conducted, resulting in a total of 55 seconds of successful engine operation. The engine is being developed by the Rocketdyne Propulsion and Power unit of the Boeing Company. Integrated launch abort demonstration tests in 2005 will use four RS-88 engines to separate a test vehicle from a test platform, simulating pulling a crewed vehicle away from an aborted launch. Four 156-foot parachutes will deploy and carry the vehicle to landing. Lockheed Martin is building the vehicles for the PAD tests. Seven integrated tests are plarned for 2005 and 2006.
2003-12-01
In this photo, an RS-88 development rocket engine is being test fired at NASA's Marshall Space Flight Center in Huntsville, Alabama, in support of the Pad Abort Demonstration (PAD) test flights for NASA's Orbital Space Plane (OSP). The tests could be instrumental in developing the first crew launch escape system in almost 30 years. Paving the way for a series of integrated PAD test flights, the engine tests support development of a system that could pull a crew safely away from danger during liftoff. A series of 16 hot fire tests of a 50,000-pound thrust RS-88 rocket engine were conducted, resulting in a total of 55 seconds of successful engine operation. The engine is being developed by the Rocketdyne Propulsion and Power unit of the Boeing Company. Integrated launch abort demonstration tests in 2005 will use four RS-88 engines to separate a test vehicle from a test platform, simulating pulling a crewed vehicle away from an aborted launch. Four 156-foot parachutes will deploy and carry the vehicle to landing. Lockheed Martin is building the vehicles for the PAD tests. Seven integrated tests are plarned for 2005 and 2006.
A quarantine protocol for analysis of returned extraterrestrial samples
NASA Technical Reports Server (NTRS)
Bagby, J. R.; Sweet, H. C.; Devincenzi, D. L.
1983-01-01
A protocol is presented for the analysis at an earth-orbiting quarantine facility of return samples of extraterrestrial material that might contain (nonterrestrial) life forms. The protocol consists of a series of tests designed to determine whether the sample, conceptualized as a 1-kg sample of Martian soil, is free from nonterrestrial biologically active agents and so may safely be sent to a terrestrial containment facility, or it exhibits biological activity requiring further (second-order) testing outside the biosphere. The first-order testing procedure seeks to detect the presence of any replicating organisms or toxic substances through a series of experiments including gas sampling, analysis of radioactivity, stereomicroscopic inspection, chemical analysis, microscopic examination, the search for metabolic products under growth conditions, microbiologicl assays, and the challenge of cultured cells with any agents found or with the extraterrestrial material as is. Detailed plans for the second-order testing would be developed in response to the actual data received from primary testing.
Executive Summary of Propulsion on the Orion Abort Flight-Test Vehicles
NASA Technical Reports Server (NTRS)
Jones, Daniel S.; Koelfgen, Syri J.; Barnes, Marvin W.; McCauley, Rachel J.; Wall, Terry M.; Reed, Brian D.; Duncan, C. Miguel
2012-01-01
The NASA Orion Flight Test Office was tasked with conducting a series of flight tests in several launch abort scenarios to certify that the Orion Launch Abort System is capable of delivering astronauts aboard the Orion Crew Module to a safe environment, away from a failed booster. The first of this series was the Orion Pad Abort 1 Flight-Test Vehicle, which was successfully flown on May 6, 2010 at the White Sands Missile Range in New Mexico. This paper provides a brief overview of the three propulsive subsystems used on the Pad Abort 1 Flight-Test Vehicle. An overview of the propulsive systems originally planned for future flight-test vehicles is also provided, which also includes the cold gas Reaction Control System within the Crew Module, and the Peacekeeper first stage rocket motor encased within the Abort Test Booster aeroshell. Although the Constellation program has been cancelled and the operational role of the Orion spacecraft has significantly evolved, lessons learned from Pad Abort 1 and the other flight-test vehicles could certainly contribute to the vehicle architecture of many future human-rated space launch vehicles.
NASA Technical Reports Server (NTRS)
Lubey, Daniel P.; Thiele, Sara R.; Gruseck, Madelyn L.; Evans, Carol T.
2010-01-01
Though getting astronauts safely into orbit and beyond has long been one of NASA?s chief goals, their safe return has always been equally as important. The Crew Exploration Vehicle?s (CEV) Parachute Assembly System (CPAS) is designed to safely return astronauts to Earth on the next-generation manned spacecraft Orion. As one means for validating this system?s requirements and testing its functionality, a test article known as the Parachute Compartment Drop Test Vehicle (PC-DTV) will carry a fully-loaded yet truncated CPAS Parachute Compartment (PC) in a series of drop tests. Two aerodynamic profiles for the PC-DTV currently exist, though both share the same interior structure, and both have an Orion-representative weight of 20,800 lbf. Two extraction methods have been developed as well. The first (Cradle Monorail System 2 - CMS2) uses a sliding rail technique to release the PC-DTV midair, and the second (Modified DTV Sled; MDS) features a much less constrained separation method though slightly more complex. The decision as to which aerodynamic profile and extraction method to use is still not finalized. Additional CFD and stress analysis must be undertaken in order to determine the more desirable options, though at present the "boat tail" profile and the CMS2 extraction method seem to be the favored options in their respective categories. Fabrication of the PC-DTV and the selected extraction sled is set to begin in early October 2010 with an anticipated first drop test in mid-March 2011.
Electrostatic Evaluation of the Propellant Handlers Ensemble
NASA Technical Reports Server (NTRS)
Hogue, Michael D.; Calle, Carlos I.; Buhler, Charles
2006-01-01
The Self-Contained Atmospheric Protective Ensemble (SCAPE) used in propellant handling at NASA's Kennedy Space Center (KSC) has recently completed a series of tests to determine its electrostatic properties of the coverall fabric used in the Propellant Handlers Ensemble (PHE). Understanding these electrostatic properties are fundamental to ensuring safe operations when working with flammable rocket propellants such as hydrazine, methyl hydrazine, and unsymmetrical dimethyl hydrazine. These tests include surface resistivity, charge decay, triboelectric charging, and flame incendivity. In this presentation, we will discuss the results of these tests on the current PHE as well as new fabrics and materials being evaluated for the next generation of PHE.
ERIC Educational Resources Information Center
Evans, Cal
Part of a series of monographs on safe, drug-free, and effective schools, this monograph discusses the new discipline requirements under the Individuals with Disabilities Education Act and the role of administrators in developing a range of intervention strategies to manage the behavior of students with behavior problems. Following an introductory…
NASA Technical Reports Server (NTRS)
Scibbe, H. W.; Winn, L. W.; Eusepi, M.
1976-01-01
The bearing, consisting of a 150-mm ball bearing and a centrifugally actuated, conical, fluid-film bearing, was fatigue tested. Test conditions were representative of a mainshaft ball bearing in a gas turbine engine operating at maximum thrust load to simulate aircraft takeoff conditions. Tests were conducted up to 16000 rpm and at this speed an axial load of 15568 newtons (3500 lb) was safely supported by the hybrid bearing system. Through the series-hybrid bearing principle, the effective ball bearing speed was reduced to approximately one-half of the shaft speed. It was concluded that a speed reduction of this magnitude results in a ten-fold increase in the ball bearing fatigue life. A successful evaluation of fluid-film bearing lubricant supply failure was performed repeatedly at an operating speed of 10,000 rpm. A complete and smooth changeover to full-scale ball bearing operation was effected when the oil supply to the fluid-film bearing was cut off. Reactivation of the fluid-film oil supply system resulted in a flawless return to the original mode of hybrid operation.
Executive Summary of Propulsion on the Orion Abort Flight-Test Vehicles
NASA Technical Reports Server (NTRS)
Jones, Daniel S.; Brooks, Syri J.; Barnes, Marvin W.; McCauley, Rachel J.; Wall, Terry M.; Reed, Brian D.; Duncan, C. Miguel
2012-01-01
The National Aeronautics and Space Administration Orion Flight Test Office was tasked with conducting a series of flight tests in several launch abort scenarios to certify that the Orion Launch Abort System is capable of delivering astronauts aboard the Orion Crew Module to a safe environment, away from a failed booster. The first of this series was the Orion Pad Abort 1 Flight-Test Vehicle, which was successfully flown on May 6, 2010 at the White Sands Missile Range in New Mexico. This report provides a brief overview of the three propulsive subsystems used on the Pad Abort 1 Flight-Test Vehicle. An overview of the propulsive systems originally planned for future flight-test vehicles is also provided, which also includes the cold gas Reaction Control System within the Crew Module, and the Peacekeeper first stage rocket motor encased within the Abort Test Booster aeroshell. Although the Constellation program has been cancelled and the operational role of the Orion spacecraft has significantly evolved, lessons learned from Pad Abort 1 and the other flight-test vehicles could certainly contribute to the vehicle architecture of many future human-rated space launch vehicles
NASA Technical Reports Server (NTRS)
Eusepi, M.; Winn, L. W.
1975-01-01
Results of tests made to determine the experimental performance of a series hybrid bearing are reported. The bearing consists of a 150 mm ball bearing and a centrifugally actuated, conical, fluid film bearing fitting an envelope with an outer radius of 86.4 mm (3.4 in.) and inner radius of 71 mm (2.8 in.). Tests were conducted up to 16,500 rpm, at which speed an axial load of 15,568 N (3500 lb) was safely supported by the hybrid bearing system. Through the employment of the series hybrid bearing principle, it was possible to reduce the effective ball bearing speed to approximately one-half of the shaft speed. A reduction of this magnitude should result in a tenfold increase in the ball bearing fatigue life. A successful simulation of fluid film bearing lubricant supply failure, performed repeatedly at an operating speed of 10,000 rpm, resulted in complete and smooth change over to full scale ball bearing operation when the oil supply to the fluid film bearing was discontinued. Reactivation of the fluid film supply system produced a flawless return to the original mode of hybrid operation.
Summary of CPAS Gen II Parachute Analysis
NASA Technical Reports Server (NTRS)
Morris, Aaron L.; Bledsoe, Kristin J.; Fraire, Usbaldo, Jr.; Moore, James W.; Olson, Leah M.; Ray, Eric
2011-01-01
The Orion spacecraft is currently under development by NASA and Lockheed Martin. Like Apollo, Orion will use a series of parachutes to slow its descent and splashdown safely. The Orion parachute system, known as the CEV Parachute Assembly System (CPAS), is being designed by NASA, the Engineering and Science Contract Group (ESCG), and Airborne Systems. The first generation (Gen I) of CPAS testing consisted of thirteen tests and was executed in the 2007-2008 timeframe. The Gen I tests provided an initial understanding of the CPAS parachutes. Knowledge gained from Gen I testing was used to plan the second generation of testing (Gen II). Gen II consisted of six tests: three singleparachute tests, designated as Main Development Tests, and three Cluster Development Tests. Gen II required a more thorough investigation into parachute performance than Gen I. Higher fidelity instrumentation, enhanced analysis methods and tools, and advanced test techniques were developed. The results of the Gen II test series are being incorporated into the CPAS design. Further testing and refinement of the design and model of parachute performance will occur during the upcoming third generation of testing (Gen III). This paper will provide an overview of the developments in CPAS analysis following the end of Gen I, including descriptions of new tools and techniques as well as overviews of the Gen II tests.
Anaphylaxis to Gelofusine confirmed by in vitro basophil activation test: a case series.
Apostolou, E; Deckert, K; Puy, R; Sandrini, A; de Leon, M P; Douglass, J A; Rolland, J M; O'hehir, R E
2006-03-01
The plasma expander Gelofusine (succinylated gelatin) is a recognised cause of peri-operative anaphylaxis. Current diagnosis of Gelofusine sensitivity is by skin testing, a procedure that itself carries a risk of allergic reaction. We evaluated the reliability of the in vitro basophil activation test as a diagnostic assay for Gelofusine sensitivity in subjects with a clinical history highly suggestive of Gelofusine allergy. Six patients with peri-operative anaphylaxis clinically attributed to Gelofusine were skin tested to confirm sensitivity. Control subjects included three healthy subjects and five subjects allergic to a neuromuscular blocking drug, all negative on Gelofusine skin testing. Whole blood basophil activation to Gelofusine was analysed by flow cytometry for CD63 surface expression. All of the Gelofusine sensitive patients and one of the control allergic subjects showed positive basophil activation to Gelofusine. In this series of subjects, the basophil activation test for Gelofusine allergy had a sensitivity of 100% and a specificity of 87.5%. Our findings suggest that basophil activation testing is a safe and reliable in vitro assay for prediction or confirmation of Gelofusine sensitivity in patients with high clinical suspicion of Gelofusine-induced anaphylaxis.
CPAS Preflight Drop Test Analysis Process
NASA Technical Reports Server (NTRS)
Englert, Megan E.; Bledsoe, Kristin J.; Romero, Leah M.
2015-01-01
Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.
NASA Technical Reports Server (NTRS)
Bonnice, W. F.; Motyka, P.; Wagner, E.; Hall, S. R.
1986-01-01
The performance of the orthogonal series generalized likelihood ratio (OSGLR) test in detecting and isolating commercial aircraft control surface and actuator failures is evaluated. A modification to incorporate age-weighting which significantly reduces the sensitivity of the algorithm to modeling errors is presented. The steady-state implementation of the algorithm based on a single linear model valid for a cruise flight condition is tested using a nonlinear aircraft simulation. A number of off-nominal no-failure flight conditions including maneuvers, nonzero flap deflections, different turbulence levels and steady winds were tested. Based on the no-failure decision functions produced by off-nominal flight conditions, the failure detection and isolation performance at the nominal flight condition was determined. The extension of the algorithm to a wider flight envelope by scheduling on dynamic pressure and flap deflection is examined. Based on this testing, the OSGLR algorithm should be capable of detecting control surface failures that would affect the safe operation of a commercial aircraft. Isolation may be difficult if there are several surfaces which produce similar effects on the aircraft. Extending the algorithm over the entire operating envelope of a commercial aircraft appears feasible.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-24
... and corrosion to an area within five inches of the fail-safe strap. Revision 2 of this service.... The existing AD currently requires inspections to detect cracking or corrosion of the fail-safe straps... corrective actions. Since we issued that AD, we have received additional reports of cracks in 51 fail-safe...
Pinto, Catarina; Ferreira, Cláudia; Mendes, Ana Laura; Trindade, Inês A
2017-06-01
Feelings of social safeness and connectedness have been associated with adaptive emotion regulation processes and well-being indicators. Further, literature has demonstrated that interpersonal experiences play an important role in the etiology and maintenance of body and eating psychopathology. However, the study of the role of social variables and emotion regulation processes in the engagement in inflexible eating rules and eating psychopathology is still in its early stages. The current study aims to fill some gaps within the literature and explore the mediator role of body appreciation and inflexible eating rules in the link between social safeness and disordered eating. Participants were 253 women, aged between 18 and 50 years old, who completed a series of online self-report measures. Results from the tested path analysis model showed that social safeness holds a significant effect on eating psychopathology, through the mechanisms of body appreciation and inflexible eating rules. Also, results suggested that women who present higher levels of social safeness tend to present a more positive and respectful attitude towards their body and decreased adoption of inflexible eating rules, which seem to explain lower levels of disordered eating behaviours. These findings seem to present empirical support for the development of intervention programs that promote a positive, affectionate and healthy relationship with one's body image, in order to prevent the inflexible adherence to eating rules and disordered eating behaviours.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-07
... removing corrosion from fail-safe straps. We have received Boeing Service Bulletin 767-53A0100, Revision 3.... That AD currently requires inspections to detect cracking or corrosion of the fail-safe straps between... cracks in 51 fail-safe straps on 41 airplanes; we have also received a report of a crack found in the ``T...
Safe Use of Pesticides, Guidelines. Occupational Safety and Health Series No. 38.
ERIC Educational Resources Information Center
International Labour Office, Geneva (Switzerland).
This document provides guidance on the safe use of pesticides in agricultural work. General principles are given and followed by more detailed safety requirements for the various pesticide application techniques. Finally, the medical aspects of pesticides are considered. (BB)
Mahony, Mary C; Patterson, Patricia; Hayward, Brooke; North, Robert; Green, Dawne
2015-05-01
To demonstrate, using human factors engineering (HFE), that a redesigned, pre-filled, ready-to-use, pre-asembled follitropin alfa pen can be used to administer prescribed follitropin alfa doses safely and accurately. A failure modes and effects analysis identified hazards and harms potentially caused by use errors; risk-control measures were implemented to ensure acceptable device use risk management. Participants were women with infertility, their significant others, and fertility nurse (FN) professionals. Preliminary testing included 'Instructions for Use' (IFU) and pre-validation studies. Validation studies used simulated injections in a representative use environment; participants received prior training on pen use. User performance in preliminary testing led to IFU revisions and a change to outer needle cap design to mitigate needle stick potential. In the first validation study (49 users, 343 simulated injections), in the FN group, one observed critical use error resulted in a device design modification and another in an IFU change. A second validation study tested the mitigation strategies; previously reported use errors were not repeated. Through an iterative process involving a series of studies, modifications were made to the pen design and IFU. Simulated-use testing demonstrated that the redesigned pen can be used to administer follitropin alfa effectively and safely.
Boxing training for patients with Parkinson disease: a case series.
Combs, Stephanie A; Diehl, M Dyer; Staples, William H; Conn, Lindsay; Davis, Kendra; Lewis, Nicole; Schaneman, Katie
2011-01-01
A nontraditional form of exercise recently applied for patients with Parkinson disease (PD) is boxing training. The primary purpose of this case series is to describe the effects of disease severity and duration of boxing training (short term and long term) on changes in balance, mobility, and quality of life for patients with mild or moderate to severe PD. The feasibility and safety of the boxing training program also were assessed. Six patients with idiopathic PD attended 24 to 36 boxing training sessions for 12 weeks, with the option of continuing the training for an additional 24 weeks (a seventh patient attended sessions for only 4 weeks). The 90-minute sessions included boxing drills and traditional stretching, strengthening, and endurance exercises. Outcomes were tested at the baseline and after 12, 24, and 36 weeks of boxing sessions (12-, 24-, and 36-week tests). The outcome measures were the Functional Reach Test, Berg Balance Scale, Activities-specific Balance Confidence Scale, Timed "Up & Go" Test, Six-Minute Walk Test, gait speed, cadence, stride length, step width, activities of daily living and motor examination subscales of the Unified Parkinson Disease Rating Scale, and Parkinson Disease Quality of Life Scale. Six patients completed all phases of the case series, showed improvements on at least 5 of the 12 outcome measures over the baseline at the 12-week test, and showed continued improvements at the 24- and 36-week tests. Patients with mild PD typically showed improvements earlier than those with moderate to severe PD. Despite the progressive nature of PD, the patients in this case series showed short-term and long-term improvements in balance, gait, activities of daily living, and quality of life after the boxing training program. A longer duration of training was necessary for patients with moderate to severe PD to show maximal training outcomes. The boxing training program was feasible and safe for these patients with PD.
ERIC Educational Resources Information Center
Guthrie, Patricia M.
This monograph focuses on school-based practices and programs that promote safe and drug-free schools. It begins with a description of the key characteristics of schools with effective programs and provides a model for school-wide support. Necessary steps for developing an effective system of universal prevention are listed and include: (1)…
Orion Underway Recovery Test 5 (URT-5)
2016-11-01
The USS San Diego approaches the coast of San Diego, California after completion of Underway Recovery Test 5 in the Pacific Ocean. NASA's Ground Systems Development and Operations Program and the U.S. Navy conducted a series of tests, called Underway Recovery Test 5, using the ship's well deck and a test version of the Orion crew module to prepare for recovery of Orion on its return from deep space missions. The testing allowed the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
The case for a multinational Mars Surveyor Program
NASA Astrophysics Data System (ADS)
Rea, D. G.; Carr, M. H.; Craig, M. K.
1989-10-01
A coordinated multinational Mars Surveyor Program involving a series of robotic missions is proposed in order to select worthwhile human landing sites for discoveries, for safe operations, and for testing and proving technologies for making human flight to Mars possible. Some characteristics motivating exploration of the planet are briefly discussed, including the possibility of life, geological features, and meteorological conditions. The necessity for preliminary exploration of Mars by robots prior to human exploration is discussed, and the rationale behind a multinational approach for a Mars Surveyor Program is presented.
Design and evaluation of a 3 million DN series-hybrid thrust bearing
NASA Technical Reports Server (NTRS)
Scibbe, H. W.; Winn, L. W.; Eusepi, M.
1976-01-01
The design and experimental evaluation of a series-hybrid thrust bearing, consisting of a 150-mm ball bearing and a centrifugally actuated, conical, fluid-film bearing, is presented. Tests were conducted up to 16,000 rpm and at this speed an axial load of 15,600 N (3500 lb) was safely supported by the hybrid bearing system. Through the series-hybrid bearing principle, the effective ball bearing speed was reduced to approximately one-half of the shaft speed. A speed reduction of this magnitude would result in a tenfold increase in the ball bearing fatigue life. A successful evaluation of fluid-film bearing lubricant supply failure was performed repeatedly at an operating speed of 10,000 rpm. A complete and smooth changeover to full-scale ball bearing operation was effected when the oil supply to the fluid-film bearing was cut off. Reactivation of the fluid-film oil supply system produced a flawless return to the original mode of hybrid operation.
2013-05-13
CAPE CANAVERAL, Fla. -- At NASA’s Kennedy Space Center in Florida, workers move the Orion ground test vehicle, or GTA, into the Launch Equipment Test Facility, or LETF, from the Operations and Checkout Building. At the LETF, Lockheed Martin will put the GTA through a series of pyrotechnic bolt tests. The ground test vehicle is being used for path finding operations in the O&C, including simulated manufacturing and assembly procedures. Launching atop NASA's heavy-lift Space Launch System SLS, which also is under development, the Orion Multi-Purpose Crew Vehicle MPCV will serve as the exploration vehicle that will carry astronaut crews beyond low Earth orbit. It also will provide emergency abort capabilities, sustain the crew during space travel and provide safe re-entry from deep space return velocities. For more information, visit www.nasa.gov/orion. Photo credit: Jim Grossman
2013-05-13
CAPE CANAVERAL, Fla. -- At NASA’s Kennedy Space Center in Florida, workers prepare to move the Orion ground test vehicle, or GTA, from the Operations and Checkout Building to the Launch Equipment Test Facility, or LETF. At the LETF, Lockheed Martin will put the GTA through a series of pyrotechnic bolt tests. The ground test vehicle is being used for path finding operations in the O&C, including simulated manufacturing and assembly procedures. Launching atop NASA's heavy-lift Space Launch System SLS, which also is under development, the Orion Multi-Purpose Crew Vehicle MPCV will serve as the exploration vehicle that will carry astronaut crews beyond low Earth orbit. It also will provide emergency abort capabilities, sustain the crew during space travel and provide safe re-entry from deep space return velocities. For more information, visit www.nasa.gov/orion. Photo credit: Jim Grossman
2013-05-13
CAPE CANAVERAL, Fla. -- At NASA’s Kennedy Space Center in Florida, workers move the Orion ground test vehicle, or GTA, from the Operations and Checkout Building to the Launch Equipment Test Facility, or LETF. At the LETF, Lockheed Martin will put the GTA through a series of pyrotechnic bolt tests. The ground test vehicle is being used for path finding operations in the O&C, including simulated manufacturing and assembly procedures. Launching atop NASA's heavy-lift Space Launch System SLS, which also is under development, the Orion Multi-Purpose Crew Vehicle MPCV will serve as the exploration vehicle that will carry astronaut crews beyond low Earth orbit. It also will provide emergency abort capabilities, sustain the crew during space travel and provide safe re-entry from deep space return velocities. For more information, visit www.nasa.gov/orion. Photo credit: Jim Grossman
2013-05-13
CAPE CANAVERAL, Fla. -- At NASA’s Kennedy Space Center in Florida, workers move the Orion ground test vehicle, or GTA, into the Launch Equipment Test Facility, or LETF, from the Operations and Checkout Building. At the LETF, Lockheed Martin will put the GTA through a series of pyrotechnic bolt tests. The ground test vehicle is being used for path finding operations in the O&C, including simulated manufacturing and assembly procedures. Launching atop NASA's heavy-lift Space Launch System SLS, which also is under development, the Orion Multi-Purpose Crew Vehicle MPCV will serve as the exploration vehicle that will carry astronaut crews beyond low Earth orbit. It also will provide emergency abort capabilities, sustain the crew during space travel and provide safe re-entry from deep space return velocities. For more information, visit www.nasa.gov/orion. Photo credit: Jim Grossman
2013-05-13
CAPE CANAVERAL, Fla. -- At NASA’s Kennedy Space Center in Florida, Lockheed Martin crews begin uncovering the Orion ground test vehicle in the Launch Equipment Test Facility, or LETF. The GTA was moved from the Operations and Checkout Facility to the LETF for a series of pyrotechnic bolt tests. The GTA is being used for path finding operations in the O&C, including simulated manufacturing and assembly procedures. Launching atop NASA's heavy-lift Space Launch System SLS, which also is under development, the Orion Multi-Purpose Crew Vehicle MPCV will serve as the exploration vehicle that will carry astronaut crews beyond low Earth orbit. It also will provide emergency abort capabilities, sustain the crew during space travel and provide safe re-entry from deep space return velocities. For more information, visit www.nasa.gov/orion. Photo credit: Jim Grossman
2013-05-13
CAPE CANAVERAL, Fla. -- At NASA’s Kennedy Space Center in Florida, Lockheed Martin crews uncover the Orion ground test vehicle in the Launch Equipment Test Facility, or LETF. The GTA was moved from the Operations and Checkout Facility to the LETF for a series of pyrotechnic bolt tests. The GTA is being used for path finding operations in the O&C, including simulated manufacturing and assembly procedures. Launching atop NASA's heavy-lift Space Launch System SLS, which also is under development, the Orion Multi-Purpose Crew Vehicle MPCV will serve as the exploration vehicle that will carry astronaut crews beyond low Earth orbit. It also will provide emergency abort capabilities, sustain the crew during space travel and provide safe re-entry from deep space return velocities. For more information, visit www.nasa.gov/orion. Photo credit: Jim Grossman
Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe
2013-07-01
Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
2013-05-14
CAPE CANAVERAL, Fla. -- Inside the Launch Equipment Test Facility at NASA’s Kennedy Space in Florida, a second firing of the escape hold down post has occurred during a pyrotechnic bolt test on the Orion ground test vehicle. Lockheed Martin performed tests over a series of days on the explosive bolts that separate Orion from the launch abort system. Data was collected on the effect of shock waves on Orion during the explosive bolt separation. Orion is the exploration spacecraft designed to carry crews to space beyond low Earth orbit. It will provide emergency abort capability, sustain the crew during the space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of the Orion is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on a Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Jim Grossmann
Nitrogen tetroxide vapor scrubber using a recirculating liquid
NASA Technical Reports Server (NTRS)
Reisert, T. D.
1978-01-01
Scrubbers required to reduce N2O4 contamination of nitrogen vent gas streams to a safe level to preclude health hazard to personnel and to preclude adverse environmental effects were developed. The scrubber principle involved is to absorb and neutralize the N2O4 component in a closed circuit circulating water/chemical solution in a vertical counter-flow, packed-tower configuration. The operational and performance test requirements for the scrubbers consist of demonstrating that the exit gas contamination level from the scrubbers does not exceed 150 ppm oxidizer under any flow conditions up to 400 scfm with inlet concentrations of up to 100,000 ppm oxidizer. Several problems were encountered during the performance testing that led to a series of investigations and supplementary testing. It was finally necessary to change the scrubber liquors in oxidizer scrubber to successfully achieve performance requirements. The scrubbers, the test configuration, and the various tests performed are described.
Orion Underway Recovery Test 5 (URT-5)
2016-11-01
The USS San Diego approaches Naval Base San Diego in California after completion of Underway Recovery Test 5 in the Pacific Ocean. NASA's Ground Systems Development and Operations Program and the U.S. Navy conducted a series of tests using the ship's well deck and a test version of the Orion crew module to prepare for recovery of Orion on its return from deep space missions. The testing allowed the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Orion Pad Abort 1 GN and C Design and Development
NASA Technical Reports Server (NTRS)
Medina, Edgar A.; Stachowiak, Susan J.
2010-01-01
The first flight test of the Orion Abort Flight Test project is scheduled to launch in Spring 2010. This flight test is known as Pad Abort 1 (PA-1) and it is intended to accomplish a series of flight test objectives, including demonstrating the capability of the Launch Abort System (LAS) to propel the Crew Module (CM) to a safe distance from a launch vehicle during a pad abort. The PA-1 Flight Test Article (FTA) is actively controlled by a guidance, navigation, and control (GN&C) system for much of its flight. The purpose of this paper is to describe the design, development, and analysis of the PA-1 GN&C system. A description of the technical solutions that were developed to meet the challenge of satisfying many competing requirements is presented. A historical perspective of how the Orion LAV compares to the Apollo Launch Escape Vehicle (LEV) design will also be included.
Teaching Family Caregivers to Assist Safely with Mobility.
Powell-Cope, Gail; Pippins, Karla M; Young, Heather M
2017-12-01
: This article is part of a series, Supporting Family Caregivers: No Longer Home Alone, published in collaboration with the AARP Public Policy Institute. Results of focus groups, conducted as part of the AARP Public Policy Institute's No Longer Home Alone video project, supported evidence that family caregivers aren't given the information they need to manage the complex care regimens of family members. This series of articles and accompanying videos aims to help nurses provide caregivers with the tools they need to manage their family member's health care at home.The articles in this new installment of the series explain principles for promoting safe mobility that nurses should reinforce with family caregivers. Each article also includes an informational tear sheet-Information for Family Caregivers-that contains links to instructional videos. To use this series, nurses should read the article first, so they understand how best to help family caregivers, and then encourage the caregivers to watch the videos and ask questions. For additional information, see Resources for Nurses.
Child Development Associate. Safety for Young Children.
ERIC Educational Resources Information Center
Oscar Rose Junior Coll., Midwest City, OK.
This Child Development Associate (CDA) training module, one of a series of 18, provides a guide to establishing a safe and healthy preschool environment and promoting health and safety practices among preschool children. Upon completion of the module, CDA trainees are expected to be able to create a safe learning environment for children,…
Street Wise Part 2: Educating Children for Safe Bicycling
ERIC Educational Resources Information Center
Crider, Linda B.; Hall, Amanda K.
2006-01-01
This part of the "Street Wise" series incorporates essential bicycle safety skills into a one week bike unit, designed for 3rd through 6th graders. These skills require much repetition and practice but can help children develop safe traffic behaviors that save lives, such as stopping, scanning, signaling, street crossing, and avoiding…
White gauze test: a novel technique in preventing post-hepatectomy bile leak.
Yugasaravanan, K; Affirul, C A; Zamri, Z; Azlanudin, A; Bong, J J
Post-hepatectomy bile leak may lead to undesired morbidity. Multiple methods have been employed to identify this leak but can be inconclusive and taxing. This novel white gauze test is a simple and reliable method. This is a prospective study performed from January 2010 until March 2011. All open hepatic resection were included. Dry white gauze is compressed onto the transected surface and observed for bile staining. The leaking duct is repaired immediately upon detection. The process is repeated until negative. Drain was removed on postoperative day-5. Post-operative bile leak is defined as: 1. Bilirubin concentration of the drain fluid is 3 times or higher than serum; 2. Presence of intra-abdominal bile collection on imaging and upon drainage; 3. Bile leak demonstrated on postoperative cholangiography. 42 patients were recruited. Seven (16.7%) patients were cirrhotic with Child-Pugh A. White gauze test were positive for intra-operative bile leaks in 29 patients (70%), which were primarily repaired. As a result, there was no postoperative bile leak in this series. One mortality was detected in this series due to postoperative pancreatic fistula and multi organ failure. The White Gauze Test is a useful method for the prevention of bile leakage after hepatic resection. It is safe, quick and cheap.
Technology to improve quality and accountability.
Kay, Jonathan
2006-01-01
A body of evidence has been accumulated to demonstrate that current practice is not sufficiently safe for several stages of central laboratory testing. In particular, while analytical and perianalytical steps that take place within the laboratory are subjected to quality control procedures, this is not the case for several pre- and post-analytical steps. The ubiquitous application of auto-identification technology seems to represent a valuable tool for reducing error rates. A series of projects in Oxford has attempted to improve processes which support several areas of laboratory medicine, including point-of-care testing, blood transfusion, delivery and interpretation of reports, and support of decision-making by clinicians. The key tools are auto-identification, Internet communication technology, process re-engineering, and knowledge management.
75 FR 16157 - Pharmaceutical Supply Chain; Public Workshop
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-31
... supply of high quality, safe, and effective drug products and drug ingredients depends upon a series of... patients. Through a series of plenary sessions and working group breakout sessions, the workshop will... environment. Share improvements in programs and technology. Identify any barriers to securing the entire...
ERIC Educational Resources Information Center
Quackenboss, Rita, Ed.; And Others
Presented in the resource guide for the Wisconsin curriculum for educable mentally retarded students are safety education teaching units. Learning to Live Safely" is the sixth in a series of persisting life situations. The guide lists behavioral objectives, activities, and annotated resource materials (with distributors' addresses) for…
The Women's Series: Kids Alone, Safe at Home. Child Care Choices. Tutor's Guide.
ERIC Educational Resources Information Center
Baker, Catherine
This packet consists of a tutor's guide and the first two booklets of "The Women's Series." The series is part of a program of a national literacy campaign dedicated to women who cannot read well enough to use literacy skills in everyday life. The two booklets focus on child care because that is such a major concern for so many women. They are…
Orion Underway Recovery Test 5 (URT-5)
2016-10-31
U.S. Navy divers and other personnel in a small Zodiac boat secure a tether line to an attach point on a test version of the Orion crew module during Underway Recovery Test 5 in the Pacific Ocean off the coast of California. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests using the USS San Diego's well deck, the test module, various watercraft and equipment to prepare for recovery of Orion on its return from deep space missions. The testing will allow the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
NASA Technical Reports Server (NTRS)
Hogge, Edward F.; Kulkarni, Chetan S.; Vazquez, Sixto L.; Smalling, Kyle M.; Strom, Thomas H.; Hill, Boyd L.; Quach, Cuong C.
2017-01-01
This paper addresses the problem of building trust in the online prediction of a battery powered aircraft's remaining flying time. A series of flight tests is described that make use of a small electric powered unmanned aerial vehicle (eUAV) to verify the performance of the remaining flying time prediction algorithm. The estimate of remaining flying time is used to activate an alarm when the predicted remaining time is two minutes. This notifies the pilot to transition to the landing phase of the flight. A second alarm is activated when the battery charge falls below a specified limit threshold. This threshold is the point at which the battery energy reserve would no longer safely support two repeated aborted landing attempts. During the test series, the motor system is operated with the same predefined timed airspeed profile for each test. To test the robustness of the prediction, half of the tests were performed with, and half were performed without, a simulated powertrain fault. The pilot remotely engages a resistor bank at a specified time during the test flight to simulate a partial powertrain fault. The flying time prediction system is agnostic of the pilot's activation of the fault and must adapt to the vehicle's state. The time at which the limit threshold on battery charge is reached is then used to measure the accuracy of the remaining flying time predictions. Accuracy requirements for the alarms are considered and the results discussed.
Ayyagari, Raj R; Yeh, Cliff; Arici, Melih; Mojibian, Hamid; Reiner, Eric; Pollak, Jeffrey S
2016-05-01
To evaluate the safety and efficacy of percutaneous transvesicular drainage of pathologic pelvic fluid collections, a series of 15 patients who underwent 16 transvesicular drainage catheter placements was retrospectively reviewed. All patients had collections suspicious for infection that were posterior to the bladder or superior to the bladder behind loops of bowel, and were otherwise inaccessible. All 15 collections were percutaneously accessed via the bladder with standard drainage catheters. All collections resolved completely with no complications. Percutaneous transvesicular drainage was a safe and effective technique in this series, and can be considered when no direct percutaneous access routes are available. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
2007-09-13
Tests begun at Stennis Space Center's E Complex Sept. 13 evaluated a liquid oxygen lead for engine start performance, part of the A-3 Test Facility Subscale Diffuser Risk Mitigation Project at SSC's E-3 Test Facility. Phase 1 of the subscale diffuser project, completed Sept. 24, was a series of 18 hot-fire tests using a 1,000-pound liquid oxygen and gaseous hydrogen thruster to verify maximum duration and repeatability for steam generation supporting the A-3 Test Stand project. The thruster is a stand-in for NASA's developing J-2X engine, to validate a 6 percent scale version of A-3's exhaust diffuser. Testing the J-2X at altitude conditions requires an enormous diffuser. Engineers will generate nearly 4,600 pounds per second of steam to reduce pressure inside A-3's test cell to simulate altitude conditions. A-3's exhaust diffuser has to be able to withstand regulated pressure, temperatures and the safe discharge of the steam produced during those tests. Before the real thing is built, engineers hope to work out any issues on the miniature version. Phase 2 testing is scheduled to begin this month.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the third grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of third grade students, its objectives include: (1) acquiring basic knowledge of hazards and safe storage of flammable liquids; and (2) developing positive actions to prevent fires and burns or to…
Investigating Safely: A Guide for High School Teachers
ERIC Educational Resources Information Center
Texley, Juliana; Kwan, Terry; Summers, John
2004-01-01
Just as high school science is more complex than it is at lower grade levels, so are the safety issues teachers face in their classes and labs. Reduce the risks to people and place with Investigating Safely, the third and most advanced and detailed volume in NSTA's unique series of safety guidebooks for science teachers. Some of the guides 11…
Learning about Feelings. Learning at Home Series.
ERIC Educational Resources Information Center
Linke, Pam
As part of a series of booklets designed to support parents and carers of young children in the home, this issue explores the challenges that all young children face in learning to manage their feelings and emotions so they can be safe, optimistic, and enthusiastic about life and learning. Following an introductory section emphasizing the early…
Challenges of CPAS Flight Testing
NASA Technical Reports Server (NTRS)
Ray, Eric S.; Morris, Aaron L.
2011-01-01
The Crew Exploration Vehicle Parachute Assembly System (CPAS) is being designed to land the Orion Crew Module (CM) at a safe rate of descent at splashdown via a series of Drogue, Pilot, and Main parachutes. Because Orion is considerably larger and heavier than Apollo, many of the flight test techniques developed during the Apollo program must be modified. The Apollo program had a dedicated C-133 aircraft, which was modified to allow a simple airdrop of "boilerplate" flight test vehicles. However, the CPAS program must use either commercial or military assets with minimal modifications to airframes or procedures. Conceptual envelopes from 2-Degree Of Freedom trajectories are presented for several existing and novel architectures. Ideally, the technique would deliver a representative capsule shape to the desired altitude and dynamic pressure at test initiation. However, compromises must be made on the characteristics of trajectories or the fidelity of test articles to production hardware. Most of the tests to date have used traditional pallet and weight tub or missile-shaped test vehicles. New test vehicles are being designed to better incorporate Orion structural components and deploy parachutes in a more representative fashion. The first attempt to test a capsule-shaped vehicle failed due to unexpected events while setting up the test condition through a series of complex procedures. In order to avoid the loss of another expensive test article which will delay the program, simpler deployment methods are being examined and more positive control of the vehicle will be maintained. Existing challenges include interfacing with parent aircraft, separating test vehicles, achieving test conditions, and landing within limited test ranges. All these challenges must be met within cost and schedule limits.
Wind pressure testing of tornado safe room components made from wood
Robert Falk; Deepak Shrestha
2016-01-01
To evaluate the ability of a wood tornado safe room to resist wind pressures produced by a tornado, two safe room com-ponents were tested for wind pressure strength. A tornado safe room ceiling panel and door were static-pressure-tested according to ASTM E 330 using a vacuum test system. Re-sults indicate that the panels had load capacities from 2.4 to 3.5 times that...
2013-10-24
CAPE CANAVERAL, Fla. – Inside the Orion Test and Launch Control Center at NASA’s Kennedy Space Center in Florida, engineers monitor data for the first Exploration Flight Test 1, or EFT-1, power up test. NASA’s first-ever deep space craft, Orion, was powered on for the first time, marking a major milestone in the final year of preparations for flight. Orion’s avionics system was installed on the crew module and powered up for a series of systems tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion, EFT-1, is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit www.nasa.gov/orion. Photo credit: Dimitri Gerondidakis
2013-10-24
CAPE CANAVERAL, Fla. – Inside the Orion Test and Launch Control Center at NASA’s Kennedy Space Center in Florida, an engineer prepares for the first Exploration Flight Test 1, or EFT-1, power up test. NASA’s first-ever deep space craft, Orion, was powered on for the first time, marking a major milestone in the final year of preparations for flight. Orion’s avionics system was installed on the crew module and powered up for a series of systems tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion, EFT-1, is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit www.nasa.gov/orion. Photo credit: Dimitri Gerondidakis
2013-10-24
CAPE CANAVERAL, Fla. – Inside the Orion Test and Launch Control Center at NASA’s Kennedy Space Center in Florida, engineers prepare for the first Exploration Flight Test 1, or EFT-1, power up test. NASA’s first-ever deep space craft, Orion, was powered on for the first time, marking a major milestone in the final year of preparations for flight. Orion’s avionics system was installed on the crew module and powered up for a series of systems tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion, EFT-1, is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit www.nasa.gov/orion. Photo credit: Dimitri Gerondidakis
2013-10-24
CAPE CANAVERAL, Fla. – Inside the Orion Test and Launch Control Center at NASA’s Kennedy Space Center in Florida, engineers prepare for the first Exploration Flight Test 1, or EFT-1, power up test. NASA’s first-ever deep space craft, Orion, was powered on for the first time, marking a major milestone in the final year of preparations for flight. Orion’s avionics system was installed on the crew module and powered up for a series of systems tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion, EFT-1, is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit www.nasa.gov/orion. Photo credit: Dimitri Gerondidakis
2013-10-24
CAPE CANAVERAL, Fla. – Inside the Orion Test and Launch Control Center at NASA’s Kennedy Space Center in Florida, engineers monitor data during the first Exploration Flight Test 1, or EFT-1, power up test. NASA’s first-ever deep space craft, Orion, was powered on for the first time, marking a major milestone in the final year of preparations for flight. Orion’s avionics system was installed on the crew module and powered up for a series of systems tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion, EFT-1, is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit www.nasa.gov/orion. Photo credit: Dimitri Gerondidakis
2013-10-24
CAPE CANAVERAL, Fla. – Inside the Orion Test and Launch Control Center at NASA’s Kennedy Space Center in Florida, engineers prepare for the first Exploration Flight Test 1, or EFT-1, power up test. NASA’s first-ever deep space craft, Orion, was powered on for the first time, marking a major milestone in the final year of preparations for flight. Orion’s avionics system was installed on the crew module and powered up for a series of systems tests. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of Orion, EFT-1, is scheduled to launch in 2014 atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit www.nasa.gov/orion. Photo credit: Dimitri Gerondidakis
Orion Underway Recovery Test 5 (URT-5)
2016-10-27
U.S. Navy divers and other personnel in a rigid hull Zodiac boat have attached tether lines to a test version of the Orion crew module during Underway Recovery Test 5 in the Pacific Ocean off the coast of California. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests using the USS San Diego, various watercraft and equipment to practice for recovery of Orion on its return from deep space missions. The testing will allow the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Orion Underway Recovery Test 5 (URT-5)
2016-10-28
Several rigid hull and inflatable Zodiac boats are in the water near a test version of the Orion crew module during the third day of Underway Recovery Test 5 in the Pacific Ocean off the coast of California. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests using the USS San Diego, various watercraft and equipment to prepare for recovery of Orion on its return from deep space missions. The test will allow the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Lithium-ion batteries for hearing aid applications. II. Pulse discharge and safety tests
NASA Astrophysics Data System (ADS)
Passerini, S.; Coustier, F.; Owens, B. B.
Rechargeable lithium-ion batteries were designed to meet the power requirements of hearing aid devices (HADs). The batteries were designed in a 312-button cell size, compatible with existing hearing aids. The batteries were tested to evaluate the design and the electrochemical performance, as they relate to a typical hearing aid application. The present report covers the pulse capabilities, cycle life and preliminary safety tests. The results are compared with other battery chemistries: secondary lithium-alloy and nickel-metal hydride batteries and primary Zn-air batteries. The cell AC impedance was stable over the frequency range between 1 and 50 kHz, ranging between 5 Ω at the higher frequency and 12 Ω at the lower extreme. Pulse tests were consistent with these values, as the cells were capable of providing a series of 100 mA pulses of 10-s duration. The safety tests suggest that the design is intrinsically safe with respect to the most common types of abuse conditions.
X-38 flies free from NASA's B-52 mothership, July 10, 2001
NASA Technical Reports Server (NTRS)
2001-01-01
The second free-flight test of an evolving series of X-38 prototypes took place July 10, 2001 when the X-38 was released from NASA's B-52 mothership over the Edwards Air Force Base range in California's Mojave Desert. Shortly after the photo was taken, a sequenced deployment of a drogue parachute followed by a large parafoil fabric wing slowed the X-38 to enable it to land safely on Rogers Dry Lake at Edwards. NASA engineers from the Dryden Flight Research Center at Edwards, and the Johnson Space Center, Houston, Texas, are developing a 'lifeboat' for the International Space Station based on X-38 research.
X-38 flies free from NASA's B-52 mothership, July 10, 2001
2001-07-10
The second free-flight test of an evolving series of X-38 prototypes took place July 10, 2001 when the X-38 was released from NASA's B-52 mothership over the Edwards Air Force Base range in California's Mojave Desert. Shortly after the photo was taken, a sequenced deployment of a drogue parachute followed by a large parafoil fabric wing slowed the X-38 to enable it to land safely on Rogers Dry Lake at Edwards. NASA engineers from the Dryden Flight Research Center at Edwards, and the Johnson Space Center, Houston, Texas, are developing a "lifeboat" for the International Space Station based on X-38 research.
Lithium/sulfur dioxide cell and battery safety
NASA Technical Reports Server (NTRS)
Halpert, G.; Anderson, A.
1982-01-01
The new high-energy lithium/sulfur dioxide primary electrochemical cell, having a number of advantages, has received considerable attention as a power source in the past few years. With greater experience and improved design by the manufacturers, this system can be used in a safe manner provided the guidelines for use and safety precautions described herein are followed. In addition to a description of cell design and appropriate definitions, there is a safety precautions checklist provided to guide the user. Specific safety procedures for marking, handling, transportation, and disposal are also given, as is a suggested series of tests, to assure manufacturer conformance to requirements.
Safe arming system for two-explosive munitions
Jaroska, Miles F.; Niven, William A.; Morrison, Jasper J.
1978-01-01
A system for safely and positively detonating high-explosive munitions, including a source of electrical signals, a split-phase square-loop transformer responsive solely to a unique series of signals from the source for charging an energy storage circuit through a voltage doubling circuit, and a spark-gap trigger for initiating discharge of the energy in the storage circuit to actuate a detonator and thereby fire the munitions.
New angles on energy correlation functions
Moult, Ian; Necib, Lina; Thaler, Jesse
2016-12-29
Jet substructure observables, designed to identify specific features within jets, play an essential role at the Large Hadron Collider (LHC), both for searching for signals beyond the Standard Model and for testing QCD in extreme phase space regions. In this paper, we systematically study the structure of infrared and collinear safe substructure observables, defining a generalization of the energy correlation functions to probe n-particle correlations within a jet. These generalized correlators provide a flexible basis for constructing new substructure observables optimized for specific purposes. Focusing on three major targets of the jet substructure community — boosted top tagging, boosted W/Z/Hmore » tagging, and quark/gluon discrimination — we use power-counting techniques to identify three new series of powerful discriminants: M i, N i, and U i. The Mi series is designed for use on groomed jets, providing a novel example of observables with improved discrimination power after the removal of soft radiation. The N i series behave parametrically like the N -subjettiness ratio observables, but are defined without respect to subjet axes, exhibiting improved behavior in the unresolved limit. Finally, the U i series improves quark/gluon discrimination by using higher-point correlators to simultaneously probe multiple emissions within a jet. Taken together, these observables broaden the scope for jet substructure studies at the LHC.« less
New angles on energy correlation functions
NASA Astrophysics Data System (ADS)
Moult, Ian; Necib, Lina; Thaler, Jesse
2016-12-01
Jet substructure observables, designed to identify specific features within jets, play an essential role at the Large Hadron Collider (LHC), both for searching for signals beyond the Standard Model and for testing QCD in extreme phase space regions. In this paper, we systematically study the structure of infrared and collinear safe substructure observables, defining a generalization of the energy correlation functions to probe n-particle correlations within a jet. These generalized correlators provide a flexible basis for constructing new substructure observables optimized for specific purposes. Focusing on three major targets of the jet substructure community — boosted top tagging, boosted W/Z/H tagging, and quark/gluon discrimination — we use power-counting techniques to identify three new series of powerful discriminants: M i , N i , and U i . The M i series is designed for use on groomed jets, providing a novel example of observables with improved discrimination power after the removal of soft radiation. The N i series behave parametrically like the N -subjettiness ratio observables, but are defined without respect to subjet axes, exhibiting improved behavior in the unresolved limit. Finally, the U i series improves quark/gluon discrimination by using higher-point correlators to simultaneously probe multiple emissions within a jet. Taken together, these observables broaden the scope for jet substructure studies at the LHC.
Direct Simple Shear Test Data Analysis using Jupyter Notebooks on DesignSafe-CI
NASA Astrophysics Data System (ADS)
Eslami, M.; Esteva, M.; Brandenberg, S. J.
2017-12-01
Due to the large number of files and their complex structure, managing data generated during natural hazards experiments requires scalable and specialized tools. DesignSafe-CI (https://www.designsafe-ci.org/) is a web-based research platform that provides computational tools to analyze, curate, and publish critical data for natural hazards research making it understandable and reusable. We present a use case from a series of Direct Simple Shear (DSS) experiments in which we used DS-CI to post-process, visualize, publish, and enable further analysis of the data. Current practice in geotechnical design against earthquakes relies on the soil's plasticity index (PI) to assess liquefaction susceptibility, and cyclic softening triggering procedures, although, quite divergent recommendations on recommended levels of plasticity can be found in the literature for these purposes. A series of cyclic and monotonic direct simple shear experiments was conducted on three low-plasticity fine-grained mixtures at the same plasticity index to examine the effectiveness of the PI in characterization of these types of materials. Results revealed that plasticity index is an insufficient indicator of the cyclic behavior of low-plasticity fine-grained soils, and corrections for pore fluid chemistry and clay minerology may be necessary for future liquefaction susceptibility and cyclic softening assessment procedures. Each monotonic, or cyclic experiment contains two stages; consolidation and shear, which include time series of load, displacement, and corresponding stresses and strains, as well as equivalent excess pore-water pressure. Using the DS-CI curation pipeline we categorized the data to display and describe the experiment's structure and files corresponding to each stage of the experiments. Two separate notebooks in Python 3 were created using the Jupyter application available in DS-CI. A data plotter aids visualizing the experimental data in relation to the sensor from which it was generated. The analysis notebook allows combining outcomes of multiple tests, conducting diverse analyses to find critical parameters, and developing plots at arbitrary strain levels. Using the platform aids both researchers work with the data and those reusing it.
Results of 30 kWt Safe Affordable Fission Engine (SAFE-30) primary heat transport testing
NASA Astrophysics Data System (ADS)
Pedersen, Kevin; van Dyke, Melissa; Houts, Mike; Godfroy, Tom; Martin, James; Dickens, Ricky; Williams, Eric; Harper, Roger; Salvil, Pat; Reid, Bob
2001-02-01
The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on the Safe Affordable Fission Engine-30 kilowatt (SAFE30) test article are being performed at the Marshall Space Flight Center. This paper discusses the results of these experiments to date, and describes the additional testing that will be performed. Recommendations related to the design of testable space fission power and propulsion systems are made. .
UAS-NAS Flight Test Series 3: Test Environment Report
NASA Technical Reports Server (NTRS)
Hoang, Ty; Murphy, Jim; Otto, Neil
2016-01-01
The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration in the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability (SSI), Human Systems Integration (HSI), and Communications (Comm), and Certification to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Detect and Avoid (DAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project is conducting a series of human-in-the-loop (HITL) and flight test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity, and complexity of the previous tests and technical simulations, resulting in research findings that support the development of regulations governing the access of UAS into the NAS. The integrated events started with two initial flight test used to develop and test early integrations and components of the test environment. Test subjects and a relevant test environment were brought in for the integrated HITL (or IHITL) conducted in 2014. The IHITL collected data to evaluate the effectiveness of DAA Well Clear (DWC) algorithms and the acceptability of UAS concepts integrated into the NAS. The first integrated flight test (and the subject of this report) followed the IHITL by replacing the simulation components with live aircraft. The project finishes the integrated events with a final flight test to be conducted in 2016 that provides the researchers with an opportunity to collect DWC and Collision Avoidance (CA) interoperability data during flight encounters.
Skin testing for immediate hypersensitivity to corticosteroids: a case series and literature review.
Baker, A; Empson, M; The, R; Fitzharris, P
2015-03-01
Immediate hypersensitivity to corticosteroids is reported to occur with an incidence of 0.1%. The largest previous case series reporting corticosteroid skin testing has seven patients. We identified 23 patients (mean age 50 years, 65% female) from Auckland City Hospital who underwent skin testing (ST) for suspected corticosteroid hypersensitivity between July 2005 and April 2012. We performed a retrospective clinical case note review detailing clinical history of reaction, skin test results and subsequent management. Most patients (21/23) had a standard panel of testing with prednisolone, triamcinolone, methylprednisolone, hydrocortisone and dexamethasone. Skin tests used a 10% steroid stock concentration for skin prick tests (SPT) and dilutions of 1 : 1000, 1 : 100 and 1 : 10 for subsequent intradermal testing. A weal 3 mm greater than the negative control was considered positive. A total of 23 patients were identified who had skin testing for suspected acute hypersensitivity to corticosteroids, eight of which had a history of anaphylaxis. From 28 reactions (in 23 patients), the most common route of administration was intra-articular (13), followed by oral (7), intravenous (3) and other (5). Skin tests were positive in 8/23 patients, and 7/8 of these patients had a history of corticosteroid-associated anaphylaxis. Skin tests were positive at either the skin prick test or intradermal stages. There was evidence suggesting clinical and skin test cross-reactivity between corticosteroids in one patient. One patient had a positive skin test, but negative oral challenge suggesting the skin test was false positive. Skin tests were negative in 15/23 patients. One patient had a negative prednisolone skin test and positive unblinded oral challenge, suggesting a false-negative skin test. Skin testing can provide sufficient evidence to diagnose allergy in patients with a clear history of immediate hypersensitivity to corticosteroids such as anaphylaxis. Both skin prick and intradermal tests should be used. There is evidence of cross-reactivity between steroids, so a panel is recommended. False-positive and false-negative reactions do occur; however, the frequency is unknown. Challenge remains the only definitive way to demonstrate a safe alternative to use. As the largest case series described, this article provides new evidence for the interpretation of skin tests when investigating possible immediate hypersensitivity to corticosteroids. © 2014 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Song, Jun Hee; Kim, Hak Kun; Kim, Sam Yeon
2014-07-01
Laminated fiber-reinforced composites can be applied to an insulating structure of a nuclear fusion device. It is necessary to investigate the interlaminar fracture characteristics of the laminated composites for the assurance of design and structural integrity. The three methods used to prepare the glass fiber reinforced plastic composites tested in this study were vacuum pressure impregnation, high pressure laminate (HPL), and prepreg laminate. We discuss the design criteria for safe application of composites and the shear-compressive test methods for evaluating mechanical properties of the material. Shear-compressive tests could be performed successfully using series-type test jigs that were inclined 0°, 30°, 45°, 60°, and 75° to the normal axis. Shear strength depends strongly on the applied compressive stress. The design range of allowable shear stress was extended by use of the appropriate composite fabrication method. HPL had the largest design range, and the allowable interlaminar shear stress was 0.254 times the compressive stress.
ERIC Educational Resources Information Center
Caron, Jean; Julien, Marie; Huang, Jean Hua
2008-01-01
This study presents the changes in the overall and firearm suicide rates for Quebec (Canada) before and after Bill C-17, which was implemented to secure safe storage of firearms. It covers 20,009 suicide cases reported to the coroner's office. Interrupted time series analysis is used to compare suicide rates in the two periods. Firearm suicide…
Final Report - Assessment of Testing Options for the NTR at the INL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Howe, Steven D; McLing, Travis L; McCurry, Michael
One of the main technologies that can be developed to dramatically enhance the human exploration of space is the nuclear thermal rocket (NTR). Several studies over the past thirty years have shown that the NTR can reduce the cost of a lunar outpost, reduce the risk of a human mission to Mars, enable fast transits for most missions throughout the solar system, and reduce the cost and time for robotic probes to deep space. Three separate committees of the National Research Council of the National Academy of Sciences have recommended that NASA develop the NTR. One of the primary issuesmore » in development of the NTR is the ability to verify a flight ready unit. Three main methods can be used to validate safe operation of a NTR: 1) Full power, full duration test in an above ground facility that scrubs the rocket exhaust clean of any fission products; 2) Full power , full duration test using the Subsurface Active Filtering of Exhaust (SAFE) technique to capture the exhaust in subsurface strata; 3) Test of the reactor fuel at temperature and power density in a driver reactor with subsequent first test of the fully integrated NTR in space. The first method, the above ground facility, has been studied in the past. The second method, SAFE, has been examined for application at the Nevada Test Site. The third method relies on the fact that the Nuclear Furnace series of tests in 1971 showed that the radioactive exhaust coming from graphite based fuel for the NTR could be completely scrubbed of fission products and the clean hydrogen flared into the atmosphere. Under funding from the MSFC, the Center for Space Nuclear Research (CSNR) at the Idaho National laboratory (INL) has completed a reexamination of Methods 2 and 3 for implementation at the INL site. In short, the effort performed the following: 1) Assess the geology of the INL site and determine a location suitable SAFE testing; 2) Perform calculations of gas transport throughout the geology; 3) Produce a cost estimate of a non-nuclear , sub-scale test using gas injection to validate the computational models; 4) Produce a preliminary cost estimate to build a nuclear furnace equivalent facility to test NTR fuel on a green field location on the INL site. The results show that the INL geology is substantially better suited to the SAFE testing method than the NTS site. The existence of impermeable interbeds just above the sub-surface aquifer ensure that no material from the test, radioactive or not, can enter the water table. Similar beds located just below the surface will prevent any gaseous products from reaching the surface for dispersion. The extremely high permeability of the strata between the interbeds allows rapid dispersion of the rocket exhaust. In addition, the high permeability suggests that a lower back-pressure may develop in the hole against the rocket thrust, which increases safety of operations. Finally, the cost of performing a sub-scale, non-nuclear verification experiment was determined to be $3M. The third method was assessed through discussions with INL staff resident at the site. In essence, any new Category I facility on any DOE site will cost in excess of $250M. Based on the results of this study, a cost estimate for testing a nuclear rocket at the INL site appears to be warranted. Given the fact that a new nuclear fuel may be possible that does not release any fission products, the SAFE testing option appears to be the most affordable.« less
Giessler, G A; Fischborn, G T; Schmidt, A B
2012-01-01
Microvascular clamps of various designs provide a bloodless field for a safe anastomosis but can cause intimal lesions, occupy space in confined sites and have a risk of backwalling due to vessel flattening. They are often insufficient in their haemostatic effect in plaque-filled atherosclerotic vessels. A new, CE-certified thermosensitive gel (LeGoo™) clinically proven in cardiovascular surgery allows a clampless microanastomosis technique. We operated on a series of five consecutive patients aged 24-71 years with six flaps for lower-extremity reconstruction using a clampless anastomosis technique with LeGoo™. We transplanted one fabricated chimaeric fibula plus gracilis, three gracilis muscle and one anterolateral thigh (ALT) flap. Pre- and postoperative protocols were similar to a 'standard' procedure with micro-clamps. All flaps survived completely except for a small area on fibula skin island, which was unrelated to gel use. The gel-assisted technique has a quick learning curve, according to this case series. The veins should be sutured first to prevent stasis in the flap. The gel provides circular stenting and gentle distension of the vessels for a safe and blood-free anastomotic site. It is completely dissolved after completion of the anastomosis with cold saline irrigation. Repolymerisation in the periphery will not occur, making it safe for microvascular flap surgery. From the experiences from this series and other specialities, the use of the thermosensitive gel LeGoo™ permits a safe clampless microanastomosis technique minimising mechanical vessel manipulation and compression. This makes it an attractive alternative to micro-clamps, especially for atherosclerotic arteries and confined anastomosis sites. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
A Draft Protocol for Detecting Possible Biohazards in Martian Samples Returned to Earth
NASA Technical Reports Server (NTRS)
Viso, M.; DeVincenzi, D. L.; Race, M. S.; Schad, P. J.; Stabekis, P. D.; Acevedo, S. E.; Rummel, J. D.
2002-01-01
In preparation for missions to Mars that will involve the return of samples, it is necessary to prepare for the safe receiving, handling, testing, distributing, and archiving of martian materials here on Earth. Previous groups and committees have studied selected aspects of sample return activities, but a specific protocol for handling and testing of returned -=1 samples from Mars remained to be developed. To refine the requirements for Mars sample hazard testing and to develop criteria for the subsequent release of sample materials from precautionary containment, NASA Planetary Protection Officer, working in collaboration with CNES, convened a series of workshops to produce a Protocol by which returned martian sample materials could be assessed for biological hazards and examined for evidence of life (extant or extinct), while safeguarding the samples from possible terrestrial contamination. The Draft Protocol was then reviewed by an Oversight and Review Committee formed specifically for that purpose and composed of senior scientists. In order to preserve the scientific value of returned martian samples under safe conditions, while avoiding false indications of life within the samples, the Sample Receiving Facility (SRF) is required to allow handling and processing of the Mars samples to prevent their terrestrial contamination while maintaining strict biological containment. It is anticipated that samples will be able to be shipped among appropriate containment facilities wherever necessary, under procedures developed in cooperation with international appropriate institutions. The SRF will need to provide different types of laboratory environments for carrying out, beyond sample description and curation, the various aspects of the protocol: Physical/Chemical analysis, Life Detection testing, and Biohazard testing. The main principle of these tests will be described and the criteria for release will be discussed, as well as the requirements for the SRF and its personnel.
Space Shuttle Orbiter Approach and Landing Test: Final Evaluation Report
NASA Technical Reports Server (NTRS)
1978-01-01
The Approach and Landing Test Program consisted of a series of steps leading to the demonstration of the capability of the Space Shuttle orbiter to safely approach and land under conditions similar to those planned for the final phases of an orbital flight. The tests were conducted with the orbiter mounted on top of a specially modified carrier aircraft. The first step provided airworthiness and performance verification of the carrier aircraft after modification. The second step consisted of three taxi tests and five flight tests with an inert unmanned orbiter. The third step consisted of three mated tests with an active manned orbiter. The fourth step consisted of five flights in which the orbiter was separated from the carrier aircraft. For the final two flights, the orbiter tail cone was replaced by dummy engines to simulate the actual orbital configuration. Landing gear braking and steering tests were accomplished during rollouts following the free flight landings. Ferry testing was integrated into the Approach and Landing Test Program to the extent possible. In addition, four ferry test flights were conducted with the orbiter mated to the carrier aircraft in the ferry configuration after the free-flight tests were completed.
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians load cargo into the Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians load cargo into the Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians load cargo into the Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, preparations are under way to load cargo into the Space Exploration Technologies Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians stow cargo in the Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, a cargo bag slides through the docking ring into the Space Exploration Technologies Dragon capsule for stowage for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
Orion Underway Recovery Test 5 (URT-5)
2016-10-30
U.S. Navy divers and other personnel in several rigid hull inflatable and Zodiac boats have surrounded a test version of the Orion crew module during Underway Recovery Test 5 in the Pacific Ocean off the coast of California. An orange winch line has been attached to the test module to pull it into the well deck of the USS San Diego. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests using the Navy ship, various watercraft and equipment to practice for recovery of Orion on its return from deep space missions. The testing allows the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Orion Underway Recovery Test 5 (URT-5)
2016-10-30
U. S. Navy divers and other personnel enter the well deck of the USS San Diego after another day of Underway Recovery Test 5 using a test version of the Orion crew module and several rigid hull inflatable and Zodiac boats in the Pacific Ocean off the coast of California. The test module is secured at the far end of the well deck. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests to prepare for recovery of Orion on its return from deep space missions. The testing allows the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Lassa-Vesicular Stomatitis Chimeric Virus Safely Destroys Brain Tumors
Wollmann, Guido; Drokhlyansky, Eugene; Davis, John N.; Cepko, Connie
2015-01-01
ABSTRACT High-grade tumors in the brain are among the deadliest of cancers. Here, we took a promising oncolytic virus, vesicular stomatitis virus (VSV), and tested the hypothesis that the neurotoxicity associated with the virus could be eliminated without blocking its oncolytic potential in the brain by replacing the neurotropic VSV glycoprotein with the glycoprotein from one of five different viruses, including Ebola virus, Marburg virus, lymphocytic choriomeningitis virus (LCMV), rabies virus, and Lassa virus. Based on in vitro infections of normal and tumor cells, we selected two viruses to test in vivo. Wild-type VSV was lethal when injected directly into the brain. In contrast, a novel chimeric virus (VSV-LASV-GPC) containing genes from both the Lassa virus glycoprotein precursor (GPC) and VSV showed no adverse actions within or outside the brain and targeted and completely destroyed brain cancer, including high-grade glioblastoma and melanoma, even in metastatic cancer models. When mice had two brain tumors, intratumoral VSV-LASV-GPC injection in one tumor (glioma or melanoma) led to complete tumor destruction; importantly, the virus moved contralaterally within the brain to selectively infect the second noninjected tumor. A chimeric virus combining VSV genes with the gene coding for the Ebola virus glycoprotein was safe in the brain and also selectively targeted brain tumors but was substantially less effective in destroying brain tumors and prolonging survival of tumor-bearing mice. A tropism for multiple cancer types combined with an exquisite tumor specificity opens a new door to widespread application of VSV-LASV-GPC as a safe and efficacious oncolytic chimeric virus within the brain. IMPORTANCE Many viruses have been tested for their ability to target and kill cancer cells. Vesicular stomatitis virus (VSV) has shown substantial promise, but a key problem is that if it enters the brain, it can generate adverse neurologic consequences, including death. We tested a series of chimeric viruses containing genes coding for VSV, together with a gene coding for the glycoprotein from other viruses, including Ebola virus, Lassa virus, LCMV, rabies virus, and Marburg virus, which was substituted for the VSV glycoprotein gene. Ebola and Lassa chimeric viruses were safe in the brain and targeted brain tumors. Lassa-VSV was particularly effective, showed no adverse side effects even when injected directly into the brain, and targeted and destroyed two different types of deadly brain cancer, including glioblastoma and melanoma. PMID:25878115
Therapeutic Assessment of Complex Trauma: A Single-Case Time-Series Study.
Tarocchi, Anna; Aschieri, Filippo; Fantini, Francesca; Smith, Justin D
2013-06-01
The cumulative effect of repeated traumatic experiences in early childhood incrementally increases the risk of adjustment problems later in life. Surviving traumatic environments can lead to the development of an interrelated constellation of emotional and interpersonal symptoms termed complex posttraumatic stress disorder (CPTSD). Effective treatment of trauma begins with a multimethod psychological assessment and requires the use of several evidence-based therapeutic processes, including establishing a safe therapeutic environment, reprocessing the trauma, constructing a new narrative, and managing emotional dysregulation. Therapeutic Assessment (TA) is a semistructured, brief intervention that uses psychological testing to promote positive change. The case study of Kelly, a middle-aged woman with a history of repeated interpersonal trauma, illustrates delivery of the TA model for CPTSD. Results of this single-case time-series experiment indicate statistically significant symptom improvement as a result of participating in TA. We discuss the implications of these findings for assessing and treating trauma-related concerns, such as CPTSD.
Therapeutic Assessment of Complex Trauma: A Single-Case Time-Series Study
Tarocchi, Anna; Aschieri, Filippo; Fantini, Francesca; Smith, Justin D.
2013-01-01
The cumulative effect of repeated traumatic experiences in early childhood incrementally increases the risk of adjustment problems later in life. Surviving traumatic environments can lead to the development of an interrelated constellation of emotional and interpersonal symptoms termed complex posttraumatic stress disorder (CPTSD). Effective treatment of trauma begins with a multimethod psychological assessment and requires the use of several evidence-based therapeutic processes, including establishing a safe therapeutic environment, reprocessing the trauma, constructing a new narrative, and managing emotional dysregulation. Therapeutic Assessment (TA) is a semistructured, brief intervention that uses psychological testing to promote positive change. The case study of Kelly, a middle-aged woman with a history of repeated interpersonal trauma, illustrates delivery of the TA model for CPTSD. Results of this single-case time-series experiment indicate statistically significant symptom improvement as a result of participating in TA. We discuss the implications of these findings for assessing and treating trauma-related concerns, such as CPTSD. PMID:24159267
NASA Technical Reports Server (NTRS)
Marshall, William M.; Borowski, Stanley K.; Bulman, Mel; Joyner, Russell; Martin, Charles R.
2015-01-01
Nuclear thermal propulsion (NTP) has been recognized as an enabling technology for missions to Mars and beyond. However, one of the key challenges of developing a nuclear thermal rocket is conducting verification and development tests on the ground. A number of ground test options are presented, with the Sub-surface Active Filtration of Exhaust (SAFE) method identified as a preferred path forward for the NTP program. The SAFE concept utilizes the natural soil characteristics present at the Nevada National Security Site to provide a natural filter for nuclear rocket exhaust during ground testing. A validation method of the SAFE concept is presented, utilizing a non-nuclear sub-scale hydrogen/oxygen rocket seeded with detectible radioisotopes. Additionally, some alternative ground test concepts, based upon the SAFE concept, are presented. Finally, an overview of the ongoing discussions of developing a ground test campaign are presented.
NASA Astrophysics Data System (ADS)
Wang, H.; Cheng, J.
2017-12-01
A method to Synthesis natural electric and magnetic Time series is proposed whereby the time series of local site are derived using an Impulse Response and a reference (STIR). The method is based on the assumption that the external source of magnetic fields are uniform, and the electric and magnetic fields acquired at the surface satisfy a time-independent linear relation in frequency domain.According to the convolution theorem, we can synthesize natural electric and magnetic time series using the impulse responses of inter-station transfer functions with a reference. Applying this method, two impulse responses need to be estimated: the quasi-MT impulse response tensor and the horizontal magnetic impulse response tensor. These impulse response tensors relate the local horizontal electric and magnetic components with the horizontal magnetic components at a reference site, respectively. Some clean segments of times series are selected to estimate impulse responses by using least-square (LS) method. STIR is similar with STIN (Wang, 2017), but STIR does not need to estimate the inter-station transfer functions, and the synthesized data are more accurate in high frequency, where STIN fails when the inter-station transfer functions are contaminated severely. A test with good quality of MT data shows that synthetic time-series are similar to natural electric and magnetic time series. For contaminated AMT example, when this method is used to remove noise present at the local site, the scatter of MT sounding curves are clear reduced, and the data quality are improved. *This work is funded by National Key R&D Program of China(2017YFC0804105),National Natural Science Foundation of China (41604064, 51574250), State Key Laboratory of Coal Resources and Safe Mining ,China University of Mining & Technology,(SKLCRSM16DC09)
Integrated Test and Evaluation Flight Test 3 Flight Test Plan
NASA Technical Reports Server (NTRS)
Marston, Michael Lawrence
2015-01-01
The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and technical simulations, resulting in research findings that support the development of regulations governing the access of UAS into the NAS.
Primary lithium organic electrolyte battery BA-5588
NASA Astrophysics Data System (ADS)
Rosansky, M. G.
1982-07-01
This program concerns the development, fabrication and evaluation of a Lithium organic electrolyte battery designated BA-5588 ()/U which incorporates five series connected, hermetically sealed cells housed in a plastic case. Significant effort was directed towards cell optimization through controlled experimentation and evaluation of various design parameters. Demonstration of the effectiveness of the finalized design was accomplished by the performance of various electrical and abuse tests which included environmental exposure, prolonged thermal storage, electrical discharge under various thermal profiles, short circuit and discharge to zero volts as well as forced discharge. The resulting evaluation demonstrated the batteries ability to operate safely under all of the specified abusive environments and provide 100% of the specified service life requirements.
Characterization of Offgas Generated During Calcination of Incinerator Ash Surrogates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wigent, H.L.; Vienna, J.D.; Darab, J.G.
1999-01-28
The Pacific Northwest National Laboratory (PNNL), in cooperation with the Los Alamos National Laboratory (LANL) and Safe Sites of Colorado (SSOC), developed a recommended flowsheet for the processing of plutonium-bearing incinerator ash stored at the Rocky Flats Environmental Technology Site (RFETS) (Lucy et al. 1998). This flowsheet involves a calcination pretreatment step, the purpose of which is to remove carbonaceous material from the incinerator ash. Removal of this material reduced the probability of process upsets, improved product quality, and increases ash waste loading. As part of the continued development of the recommended flowsheet, PNNL performed a series of tests tomore » characterize the offgas generated during the calcination process.« less
Simple amides of oleanolic acid as effective penetration enhancers.
Bednarczyk-Cwynar, Barbara; Partyka, Danuta; Zaprutko, Lucjusz
2015-01-01
Transdermal transport is now becoming one of the most convenient and safe pathways for drug delivery. In some cases it is necessary to use skin penetration enhancers in order to allow for the transdermal transport of drugs that are otherwise insufficiently skin-permeable. A series of oleanolic acid amides as potential transdermal penetration enhancers was formed by multistep synthesis and the synthesis of all newly prepared compounds is presented. The synthetized amides of oleanolic acid were tested for their in vitro penetration promoter activity. The above activity was evaluated by means of using the Fürst method. The relationships between the chemical structure of the studied compounds and penetration activity are presented.
Simple Amides of Oleanolic Acid as Effective Penetration Enhancers
Bednarczyk-Cwynar, Barbara; Partyka, Danuta; Zaprutko, Lucjusz
2015-01-01
Transdermal transport is now becoming one of the most convenient and safe pathways for drug delivery. In some cases it is necessary to use skin penetration enhancers in order to allow for the transdermal transport of drugs that are otherwise insufficiently skin-permeable. A series of oleanolic acid amides as potential transdermal penetration enhancers was formed by multistep synthesis and the synthesis of all newly prepared compounds is presented. The synthetized amides of oleanolic acid were tested for their in vitro penetration promoter activity. The above activity was evaluated by means of using the Fürst method. The relationships between the chemical structure of the studied compounds and penetration activity are presented. PMID:26010090
ERIC Educational Resources Information Center
Chipley, Michael; Lyon, Wesley; Smilowitz, Robert; Williams, Pax; Arnold, Christopher; Blewett, William; Hazen, Lee; Krimgold, Fred
2012-01-01
This publication, part of the new Building and Infrastructure Protection Series (BIPS) published by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) Infrastructure Protection and Disaster Management Division (IDD), serves to advance high performance and integrated design for buildings and infrastructure. This…
ERIC Educational Resources Information Center
Afterschool Alliance, 2014
2014-01-01
The Afterschool Alliance, in partnership with MetLife Foundation, is proud to present the third issue brief in their latest series of four issue briefs examining critical issues facing middle school youth and the vital role afterschool programs play in addressing these issues. This series explores afterschool and: the Common Core State Standards,…
A national evaluation of Safe Schools/Healthy Students: outcomes and influences.
Derzon, James H; Yu, Ping; Ellis, Bruce; Xiong, Sharon; Arroyo, Carmen; Mannix, Danyelle; Wells, Michael E; Hill, Gary; Rollison, Julia
2012-05-01
The Safe Schools/Healthy Students (SS/HS) Initiative has awarded over $2 billion in grants to more than 350 school districts in partnership with local mental health, law enforcement, and juvenile justice agencies. To estimate the impact of grantee characteristics, grant operations, and near-term outcomes in reducing violence and substance use, promoting mental health, and enhancing school safety, logged odds ratios (LORs) were calculated contrasting Year 3 with Baseline performance from grantee-provided data on seven outcome measures. After comparing grantee performance across outcomes and outcomes across grantees, the LORs were entered as dependent variables in a series of meta-regressions in which grantee characteristics, grant operations, and near-term outcomes were tested after controlling for pre-grant characteristics. Findings indicate that the SS/HS Initiative significantly improved most outcomes, that within-grantee performance varied greatly by outcome, and that random-effects meta-regression appreciably decreased the variance available for modeling. The approach demonstrates that the SS/HS Initiative is effective and that locally collected performance data can be used to estimate grantee success in improving youth outcomes. Copyright © 2011 Elsevier Ltd. All rights reserved.
Pulmonary embolism during and after pregnancy.
Stone, Sarah E; Morris, Timothy A
2005-10-01
Venous thromboembolic disease is among the most common causes of morbidity and mortality during pregnancy. The clinical evaluation alone is insufficient for the diagnosis of venous thromboembolic disease, and the normal pregnant state makes this evaluation even more challenging. Objective testing is the mainstay of diagnosis, including compression ultrasound, impedance plethysmography, ventilation-perfusion scanning, computed tomography scanning, and pulmonary angiography. All of these tests can be safety performed during pregnancy. If deep vein thrombosis or pulmonary embolism is diagnosed, anticoagulation should be initiated. Either (unfractionated) heparin or low molecular weight heparin is an acceptable treatment for acute venous thromboembolic disease. Both have risks and benefits, but both can be used safely during pregnancy. Intravenous heparin is the treatment of choice surrounding delivery due to its short half life. Because of the risk of adverse effects on the fetus, warfarin is not generally used during pregnancy. Unstable pulmonary embolism is difficult to treat during pregnancy, as there are minimal data regarding the safety and efficacy of thrombolytic therapy, inferior vena cava filters, and embolectomy during pregnancy. Case reports and case series suggest that thrombolytic therapy may be associated with lower risks of fetal loss than embolectomy. Venous thromboembolic disease is a significant cause of morbidity and mortality during pregnancy and the puerperal period. Objective testing is critical to establish the diagnosis and can be safely performed during pregnancy. Anticoagulation with heparin is the mainstay of therapy during the pregnancy, but patients may be transitioned to warfarin after delivery.
NASA Astrophysics Data System (ADS)
Zawawi, M. H.; Zahar, M. F.; Hashim, M. M. M.; Hazreek, Z. A. M.; Zahari, N. M.; Kamaruddin, M. A.
2018-04-01
Saline water intrusion is a serious threat to the groundwater as many part of the world utilize groundwater as their main source of fresh water supply. The usage of high salinity level of water as drinking water can lead to a very serious health hazard towards human. Saline water intrusion is a process by which induced flow of seawater into freshwater aquifer along the coastal area. It might happen due to human action and/or by natural event. The climate change and rise up of sea level may speed up the saline water intrusion process. The conventional method for distinguishing and checking saltwater interference to groundwater along the coast aquifers is to gather and test the groundwater from series of observation wells (borehole) with an end goal to give the important information about the hydrochemistry data to conclude whether the water in the well are safe to consume or not. An integrated approach of field and laboratory electrical resistivity investigation is proposed for indicating the contact region between saline and fresh groundwater. It was found that correlation for both soilbox produced almost identical curvilinear trends for 2% increment of seawater tested using sand sample. This project contributes towards predicting the saline water intrusion to the groundwater by non-destructive test that can replaced the conventional method of groundwater monitoring using series of boreholes in the coastal area
Sánchez-Hidalgo, J M; Salamanca-Bustos, J J; Arjona-Sánchez, Á; Campos-Hernández, J P; Ruiz Rabelo, J; Rodríguez-Benot, A; Requena-Tapia, M J; Briceño-Delgado, J
2018-03-01
Some factors affect the pancreas of a marginal donor, and although their influence on graft survival has been determined, there is an increasing consensus to accept marginal organs in a controlled manner to increase the pool of organs. Certain factors related to the recipient have also been proposed as having negative influence on graft prognosis. The objective of this study was to analyze the influence of these factors on the results of our simultaneous pancreas-kidney (SPK) transplantation series. Retrospective analysis of 126 SPK transplants. Donors and recipients were stratified in an optimal group (<2 expanded donor criteria) and a risk group (≥2 criteria). A pancreatic graft survival analysis was performed using a Kaplan-Meier test and log-rank test. Prognostic variables on graft survival were studied by Cox regression. Postoperative complications (graded by Clavien classification) were compared by χ 2 test or Fisher test. Median survival of pancreas was 66 months, with no significant difference between groups (P > .05). Multivariate analysis showed risk factors to be donor age, cold ischemia time, donor body mass index, receipt body mass index, and receipt panel-reactive antibody. In our series, the use of pancreatic grafts from donors with expanded criteria is safe and has increased the pool of grafts. Different variables, both donor and recipient, influence the survival of the pancreatic graft and should be taken into account in organ distribution systems. Copyright © 2017 Elsevier Inc. All rights reserved.
Orion Underway Recovery Test 5 (URT-5)
2016-10-28
U.S. Navy divers in an inflatable Zodiac boat approach a test version of the Orion crew module in the Pacific Ocean off the coast of California during the third day of Underway Recovery Test 5. NASA, Navy and contractor personnel monitor the recovery procedures from the deck of the USS San Diego. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests using the ship, various watercraft and equipment to prepare for recovery of Orion on its return from deep space missions. The test will allow the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Orion Underway Recovery Test 5 (URT-5)
2016-10-28
U.S. Navy divers and other personnel in a rigid hull inflatable boat are handling tether lines attached to a test version of the Orion crew module during Underway Recovery Test 5 in the Pacific Ocean off the coast of California. U.S. Navy divers in a smaller watercraft called a Zodiac boat are farther away. NASA's Ground Systems Development and Operations Program and the U.S. Navy are conducting a series of tests using the well deck of the USS San Diego, several watercraft and personnel to prepare for recovery of Orion on its return from deep space missions. The testing will allow the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
UAS Integration in the NAS Project: Integrated Test and Evaluation (IT&E) Flight Test 3. Revision E
NASA Technical Reports Server (NTRS)
Marston, Michael
2015-01-01
The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration into the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability, Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research is broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of Test Infrastructure is to enable development and validation of airspace integration procedures and performance standards, including the integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project will develop an adaptable, scalable, and schedulable relevant test environment capable of evaluating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project will conduct a series of Human-in-the-Loop and Flight Test activities that integrate key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events will build on the technical achievements, fidelity and complexity of the previous tests and technical simulations, resulting in research findings that support the development of regulations governing the access of UAS into the NAS.
Intramuscular injection technique: an evidence-based approach.
Ogston-Tuck, Sherri
2014-09-30
Intramuscular injections require a thorough and meticulous approach to patient assessment and injection technique. This article, the second in a series of two, reviews the evidence base to inform safer practice and to consider the evidence for nursing practice in this area. A framework for safe practice is included, identifying important points for safe technique, patient care and clinical decision making. It also highlights the ongoing debate in selection of intramuscular injection sites, predominately the ventrogluteal and dorsogluteal muscles.
Lower bound buckling loads for design of laminate composite cylinders
NASA Astrophysics Data System (ADS)
Croll, James G. A.; Wang, Hongtao
2017-01-01
Over a period of more than 45 years, an extensive research program has allowed a series of very simple propositions, relating to the safe design of shells experiencing imperfection sensitive buckling, to be recast in the form of a series of lemmas. These are briefly summarized and their practical use is illustrated in relation to the prediction of safe lower bounds to the imperfection sensitive buckling of axially loaded, fiber reinforced polymeric, laminated cylinders. With a fundamental aspect of the approach, sometimes referred to as the reduced stiffness method, being the delineation of the various shell membrane and bending stiffness (or perhaps more appropriately energy) components contributing to the buckling resistance, the method will be shown to also provide a powerful way of making rational design decisions to optimize the use of fiber reinforcement.
Thermodynamic processes associated with frostbite in the handling of liquid nitrogen
NASA Astrophysics Data System (ADS)
Johnson, W. L.; Cook, C. R.
2014-01-01
It is often taught that exposure to liquid nitrogen will cause frostbite or more severe damage to exposed skin tissue. However, it is also demonstrated that a full hand can be briefly immersed in liquid nitrogen without damage. To better understand and possibly visualize the effects of human tissue exposure to liquid nitrogen, a series of tests were conducted using simulated hands and arms composed of molded gelatin forms. The simulated hands and arms were immersed, sprayed, or splashed with liquid nitrogen both with and without state of the art personal protective equipment. Thermocouples were located within the test articles to allow for thermal mapping during the freezing process. The study is aimed to help understand frostbite hazards and the time constants involved with the handling of liquid nitrogen to improve future safety protocols for the safe handling of cryogenic fluids. Results of the testing also show the limits to handling liquid nitrogen while using various means of protection.
van der Voet, Hilko; Goedhart, Paul W; Schmidt, Kerstin
2017-11-01
An equivalence testing method is described to assess the safety of regulated products using relevant data obtained in historical studies with assumedly safe reference products. The method is illustrated using data from a series of animal feeding studies with genetically modified and reference maize varieties. Several criteria for quantifying equivalence are discussed, and study-corrected distribution-wise equivalence is selected as being appropriate for the example case study. An equivalence test is proposed based on a high probability of declaring equivalence in a simplified situation, where there is no between-group variation, where the historical and current studies have the same residual variance, and where the current study is assumed to have a sample size as set by a regulator. The method makes use of generalized fiducial inference methods to integrate uncertainties from both the historical and the current data. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians close the hatch of the Dragon capsule. The hatch was open for cargo to be stowed in the capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, the hatch of the Space Exploration Technologies Dragon capsule has been closed following stowage of cargo in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians prepare to close the hatch of the Dragon capsule. The hatch was open for cargo to be stowed in the capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
Overpressure resulting from combustion of explosive gas in an unconfined geometry
NASA Astrophysics Data System (ADS)
Urtiew, P. A.
1982-02-01
In preparation for a series of large scale spill tests of liquefied gaseous fuels, the problem of designing safe storage facilities for the fuels as part of a proposed spill test facility arose. The design had to take into account the potential hazards associated with large quantities of fuel, including the hazard of overpressures which develop during various modes of combustion or explosion. The overpressure question, the results of which are presented, was studied. All the pertinent information on overpressure that is available in the open literature is summarized and is presented in a form that can be readily converted into design criteria for the fuel storage facility. Various modes of combustion are reviewed and categorized according to their capability of producing sizable overpressures, and some comments are made on how deviations from the ideal situations considered in analytical studies will affect the results.
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, a Space Exploration Technologies technician attaches a cargo bag to the crane that will lift it toward the Dragon capsule where it will be stowed in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, a cargo bag is lowered into the hands of a Space Exploration Technologies technician who will load it into the Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
SSME Key Operations Demonstration
NASA Technical Reports Server (NTRS)
Anderson, Brian; Bradley, Michael; Ives, Janet
1997-01-01
A Space Shuttle Main Engine (SSME) test program was conducted between August 1995 and May 1996 using the Technology Test Bed (TTB) Engine. SSTO vehicle studies have indicated that increases in the propulsion system operating range can save significant weight and cost at the vehicle level. This test program demonstrated the ability of the SSME to accommodate a wide variation in safe operating ranges and therefore its applicability to the SSTO mission. A total of eight tests were completed with four at Marshall Space Flight Center's Advanced Engine Test Facility and four at the Stennis Space Center (SSC) A-2 attitude test stand. Key demonstration objectives were: 1) Mainstage operation at 5.4 to 6.9 mixture ratio; 2) Nominal engine start with significantly reduced engine inlet pressures of 50 psia LOX and 38 psia fuel; and 3) Low power level operation at 17%, 22%, 27%, 40%, 45%, and 50% of Rated Power Level. Use of the highly instrumented TTB engine for this test series has afforded the opportunity to study in great detail engine system operation not possible with a standard SSME and has significantly contributed to a greater understanding of the capabilities of the SSME and liquid rocket engines in general.
Test model designs for advanced refractory ceramic materials
NASA Technical Reports Server (NTRS)
Tran, Huy Kim
1993-01-01
The next generation of space vehicles will be subjected to severe aerothermal loads and will require an improved thermal protection system (TPS) and other advanced vehicle components. In order to ensure the satisfactory performance system (TPS) and other advanced vehicle materials and components, testing is to be performed in environments similar to space flight. The design and fabrication of the test models should be fairly simple but still accomplish test objectives. In the Advanced Refractory Ceramic Materials test series, the models and model holders will need to withstand the required heat fluxes of 340 to 817 W/sq cm or surface temperatures in the range of 2700 K to 3000 K. The model holders should provide one dimensional (1-D) heat transfer to the samples and the appropriate flow field without compromising the primary test objectives. The optical properties such as the effective emissivity, catalytic efficiency coefficients, thermal properties, and mass loss measurements are also taken into consideration in the design process. Therefore, it is the intent of this paper to demonstrate the design schemes for different models and model holders that would accommodate these test requirements and ensure the safe operation in a typical arc jet facility.
Fiore, Marco; Rimareix, Françoise; Mariani, Luigi; Domont, Julien; Collini, Paola; Le Péchoux, Cecile; Casali, Paolo G; Le Cesne, Axel; Gronchi, Alessandro; Bonvalot, Sylvie
2009-09-01
Surgery is still the standard treatment for desmoid-type fibromatosis (DF). Recently, the Institut Gustave Roussy (IGR), Villejuif, France, reported a series of patients treated with a front-line conservative approach (no surgery and no radiotherapy). The disease remained stable in more than half of patients. This study was designed to evaluate this approach on the natural history of the disease in a larger series of patients. A total of 142 patients presenting to the IGR or Istituto Nazionale Tumori (INT), Milan, Italy, were initially treated using a front-line deliberately conservative policy. Their progression-free survival (PFS) was observed and a multivariate analysis was performed for major clinical variables. Seventy-four patients presented with primary tumor, 68 with recurrence. Eighty-three patients received a "wait & see" policy (W&S), whereas 59 were initially offered medical therapy (MT), mainly hormonal therapy and chemotherapy. A family history of sporadic colorectal cancer was present in 8% of patients. The 5-year PFS was 49.9% for the W&S group and 58.6% for the medically treated patients (P = 0.3196). Similar results emerged for primary and recurrent DF. Multivariate analysis identified no clinical variables as independent predictors of PFS. In the event of progression, all patients were subsequently managed safely. A conservative policy could be a safe approach to primary and recurrent DF, which could avoid unnecessary morbidity from surgery and/or radiation therapy. Half of patients had medium-term stable disease after W&S or MT. A multidisciplinary, stepwise approach should be prospectively tested in DF.
Aviation Careers Series: Flight Attendants
DOT National Transportation Integrated Search
1996-01-29
Over the past 40 years, the American freight movement system became the envy of the world. Transportation builders, the motor carrier industry, and government regulators have all worked to keep goods moving safely and efficiently. Today freight movem...
Thunder and Lightning: A Lecture-Demonstration for All Ages.
ERIC Educational Resources Information Center
Baker, Colin
1999-01-01
Describes a series of simple but spectacular chemistry demonstrations designed to capture children's imaginations. The demonstrations take the minimum amount of time to prepare, are relatively safe to dispose of, and reliable. (Author/WRM)
2016-06-01
onto the eastern north Pacific circulation has been studied for years, the effect of El Nino Modoki in the region is still unclear. The CCS is...ready for combat. The main mission of Third Fleet is to provide safe, effective , relevant training to ensure Sailors have the essential skills to...Fleet. Understanding our environment and ocean currents with in the CCS improves the Navy’s ability to practice operating safely and effectively along
An Automated Safe-to-Mate (ASTM) Tester
NASA Technical Reports Server (NTRS)
Nguyen, Phuc; Scott, Michelle; Leung, Alan; Lin, Michael; Johnson, Thomas
2013-01-01
Safe-to-mate testing is a common hardware safety practice where impedance measurements are made on unpowered hardware to verify isolation, continuity, or impedance between pins of an interface connector. A computer-based instrumentation solution has been developed to resolve issues. The ASTM is connected to the circuit under test, and can then quickly, safely, and reliably safe-to-mate the entire connector, or even multiple connectors, at the same time.
Investigation and mitigation of condensation induced water hammer by stratified flow experiments
NASA Astrophysics Data System (ADS)
Kadakia, Hiral J.
This research primarily focuses on the possibility of using stratified flow in preventing an occurrence of condensation induced water hammer (CIWH) in horizontal pipe involving steam and subcooled water. A two-phase flow loop simulating the passive safety systems of an advanced light water reactor was constructed and a series of stratified flow experiments were carried out involving a system of subcooled water, saturated water, and steam. Special instruments were designed to measure steam flow rate and subcooled liquid velocity. These experiments showed that when flow field conditions meet certain criteria CIWH does occur. Flow conditions used in experiments were typically observed in passive safety systems of an advanced light water cooled reactor. This research summarizes a) literature research and other experimental data that signify an occurrence of CIWH, b) experiments in an effort to show an occurrence of CIWH and the ability to prevent CIWH, c) qualitative and quantitative results to underline the mechanism of CIWH, d) experiments that show CIWH can be prevented under certain conditions, and e) guidelines for the safe operating conditions. Based on initial experiment results it was observed that Bernoulli's effect can play an important role in wave formation and instability. A separate effect table top experiment was constructed with plexi-glass. A series of entrance effect tests and stratified experiments were carried out with different fluids to study wave formation and wave bridging. Special test series experiments were carried out to investigate the presence of a saturated layer. The effect of subcooled water and steam flow on wedge length and depth were recorded. These experiments helped create a model which calculates wedge and depth of wedge for a given condition of steam and subcooled water. A very good comparison between the experiment results and the model was obtained. These experiments also showed that the presence of saturated layer can mitigate the CIWH. Flow conditions require to mitigate the CIWH must be such that subcooled water is laminar and steam flow rate is less than critical. Finally, a data bank of containing large number of experiments was created and guidelines for safe filling and draining of the system involving steam and subcooled water were created. Also several suggestions are provided to stop CIWH in case it does occur.
Laparoscopic appendicectomy: safe and useful for training.
Duff, S. E.; Dixon, A. R.
2000-01-01
Debate exists about the benefits of laparoscopic appendicectomy when compared to a conventional open procedure. The majority of appendices are removed by the open route in the UK. We report a series of 132 cases of suspected appendicitis managed laparoscopically: 112 (85%) of the patients had acute appendicitis, the remaining 20 (15%) had non-appendiceal pathology. The median operative time was 30 min and there were no conversions to an open operative procedure. The median postoperative stay was two days. Complications were seen in two patients. The published evidence comparing laparoscopic and open appendicectomy is contradictory. Our series shows that laparoscopic appendicectomy is a safe procedure with low morbidity; it is also an excellent training tool in laparoscopic technique and, with sufficient experience, takes no longer than an open procedure. Negative appendicocecotomies are most common in women of fertile age and can be associated with significant morbidity; therefore, laparoscopy should be used to make the diagnosis and, if appendicitis is the cause, the appendix could safely be removed laparoscopically. However, the choice between open and laparoscopic procedure is a subjective decision for the patient and their surgeon. Laparoscopic appendicectomy cannot be regarded as the gold standard. PMID:11103154
2014-04-22
CAPE CANAVERAL, Fla. - Inside the Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, the Orion crew module is positioned on a special portable test chamber and prepared for a multi-point random vibration test. Accelerometers and strain gages have been attached to Orion in various locations. During a series of tests, each lasting only 30 seconds, Orion will be subjected to gradually increasing levels of vibrations that represent levels the vehicle would experience during launch, orbit and descent. The data is reviewed in order to assess the health of the crew module. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. The first unpiloted test flight of the Orion is scheduled to launch later this year atop a Delta IV rocket and in 2017 on NASA’s Space Launch System rocket. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Daniel Casper
Live Aircraft Encounter Visualization at FutureFlight Central
NASA Technical Reports Server (NTRS)
Murphy, James R.; Chinn, Fay; Monheim, Spencer; Otto, Neil; Kato, Kenji; Archdeacon, John
2018-01-01
Researchers at the National Aeronautics and Space Administration (NASA) have developed an aircraft data streaming capability that can be used to visualize live aircraft in near real-time. During a joint Federal Aviation Administration (FAA)/NASA Airborne Collision Avoidance System flight series, test sorties between unmanned aircraft and manned intruder aircraft were shown in real-time at NASA Ames' FutureFlight Central tower facility as a virtual representation of the encounter. This capability leveraged existing live surveillance, video, and audio data streams distributed through a Live, Virtual, Constructive test environment, then depicted the encounter from the point of view of any aircraft in the system showing the proximity of the other aircraft. For the demonstration, position report data were sent to the ground from on-board sensors on the unmanned aircraft. The point of view can be change dynamically, allowing encounters from all angles to be observed. Visualizing the encounters in real-time provides a safe and effective method for observation of live flight testing and a strong alternative to travel to the remote test range.
Understanding the Role of Deterrence in Counterterrorism Security
2009-11-01
30, No. 5, pp. 429–443. Enders, W., Sandler, T. (1993). “The Effectiveness of Anti-Terrorism Policies: Vector Autoregression Intervention Analysis ...occasional paper series . RAND occasional papers may include an informed perspective on a timely policy issue, a discussion of new research...United States safe? Are better means available for evaluating what may work or not and why? This series is designed to focus on a small set of
Scaddan, Emma; Rowell, John; O'Leary, Shaun
2017-09-01
Arthritis resulting from recurrent intra-articular bleeding in individuals with hemophilia can be severely debilitating due to joint pain and stiffness with subsequent loss of mobility and function. Very limited studies have investigated the potential benefits of joint mobilization for this condition. This case series is a preliminary investigation of safety, as well as immediate and short-term clinical benefits, associated with gentle knee and ankle joint mobilization in people with hemophilic arthropathy. A single intervention of joint mobilization was applied to the affected knees and/or ankles of 16 individuals with severe or moderate hemophilia within a public hospital setting. Adverse events, as well as immediate (pain-free passive joint range, Timed Up and Go Test with maximum pain numerical rating scale) and short-term (Lower Extremity Functional Scale) effects of the intervention were evaluated with a repeated measures ANOVA. There were no adverse events. An immediate significant increase was observed in pain-free passive ankle joint range of motion ( p < 0.05) following the joint mobilization intervention. The findings of this case series suggest that gentle joint mobilization techniques may be safely considered as part of a multimodal management approach for hemophilic arthropathy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lisowski, Darius D.; Kraus, Adam R.; Bucknor, Matthew D.
A 1/2 scale test facility has been constructed at Argonne National Laboratory to study the heat removal performance and natural circulation flow patterns in a Reactor Cavity Cooling System (RCCS). Our test facility, the Natural convection Shutdown heat removal Test Facility (NSTF), supports the broader goal of developing an inherently safe and fully passive ex-vessel decay heat removal for advanced reactor designs. The project, initiated in 2010 to support the Advanced Reactor Technologies (ART), Small Modular Reactor (SMR), and Next Generation Nuclear Plant (NGNP) programs, has been conducting experimental operations since early 2014. The following paper provides a summary ofmore » some primary design features of the 26-m tall test facility along with a description of the data acquisition suite that guides our experimental practices. Specifics of the distributed fiber optic temperature measurements will be discussed, which introduces an unparalleled level of data density that has never before been implemented in a large scale natural circulation test facility. Results from our test series will then be presented, which provide insight into the thermal hydraulic behavior at steady-state and transient conditions for varying heat flux levels and exhaust chimney configuration states. (C) 2016 Elsevier B.V. All rights reserved.« less
Fatigue Tests with Random Flight Simulation Loading
NASA Technical Reports Server (NTRS)
Schijve, J.
1972-01-01
Crack propagation was studied in a full-scale wing structure under different simulated flight conditions. Omission of low-amplitude gust cycles had a small effect on the crack rate. Truncation of the infrequently occurring high-amplitude gust cycles to a lower level had a noticeably accelerating effect on crack growth. The application of fail-safe load (100 percent limit load) effectively stopped subsequent crack growth under resumed flight-simulation loading. In another flight-simulation test series on sheet specimens, the variables studied are the design stress level and the cyclic frequency of the random gust loading. Inflight mean stresses vary from 5.5 to 10.0 kg/sq mm. The effect of the stress level is larger for the 2024 alloy than for the 7075 alloy. Three frequencies were employed: namely, 10 cps, 1 cps, and 0.1 cps. The frequency effect was small. The advantages and limitations of flight-simulation tests are compared with those of alternative test procedures such as constant-amplitude tests, program tests, and random-load tests. Various testing purposes are considered. The variables of flight-simulation tests are listed and their effects are discussed. A proposal is made for performing systematic flight-simulation tests in such a way that the compiled data may be used as a source of reference.
Drive and protection circuit for converter module of cascaded H-bridge STATCOM
NASA Astrophysics Data System (ADS)
Wang, Xuan; Yuan, Hongliang; Wang, Xiaoxing; Wang, Shuai; Fu, Yongsheng
2018-04-01
Drive and protection circuit is an important part of power electronics, which is related to safe and stable operation issues in the power electronics. The drive and protection circuit is designed for the cascaded H-bridge STATCOM. This circuit can realize flexible dead-time setting, operation status self-detection, fault priority protection and detailed fault status uploading. It can help to improve the reliability of STATCOM's operation. Finally, the proposed circuit is tested and analyzed by power electronic simulation software PSPICE (Simulation Program with IC Emphasis) and a series of experiments. Further studies showed that the proposed circuit can realize drive and control of H-bridge circuit, meanwhile it also can realize fast processing faults and have advantage of high reliability.
Debris flow impact estimation on a rigid barrier
NASA Astrophysics Data System (ADS)
Vagnon, Federico; Segalini, Andrea
2016-07-01
The aim of this paper is to analyse debris flow impact against rigid and undrained barrier in order to propose a new formulation for the estimation of acting force after the flow impact to safe design protection structures. For this reason, this work concentrates on the flow impact, by performing a series of small scale tests in a specifically created flume. Flow characteristics (flow height and velocity) and applied loads (dynamic and static) on barrier were measured using four ultrasonic devices, four load cells and a contact surface pressure gauge. The results obtained were compared with main existing models and a new equation is proposed. Furthermore, a brief review of the small scale theory was provided to analyse the scale effects that can affect the results.
ERIC Educational Resources Information Center
Penman, Kenneth A.; Niccolai, Frances R.
1985-01-01
The first of a series of articles explains the legal principles of tort liability, waiver of liability, comparative negligence, assumption of risk, and contributory negligence. Summarizes the kinds of cases going to court involving sport facility design and operation. (MLF)
Rapid Propellant Loading Approach Exploration
2010-11-01
the impact upon ground operations of three configuration options. Ground operations management was addressed through a series of studies performed...and operations management system can enable safe rapid propellant loading operations with limited operator knowledge and involvement. A single
Mahler, Simon A; Burke, Gregory L; Duncan, Pamela W; Case, Larry D; Herrington, David M; Riley, Robert F; Wells, Brian J; Hiestand, Brian C; Miller, Chadwick D
2016-01-22
Most patients presenting to US Emergency Departments (ED) with chest pain are hospitalized for comprehensive testing. These evaluations cost the US health system >$10 billion annually, but have a diagnostic yield for acute coronary syndrome (ACS) of <10%. The history/ECG/age/risk factors/troponin (HEART) Pathway is an accelerated diagnostic protocol (ADP), designed to improve care for patients with acute chest pain by identifying patients for early ED discharge. Prior efficacy studies demonstrate that the HEART Pathway safely reduces cardiac testing, while maintaining an acceptably low adverse event rate. The purpose of this study is to determine the effectiveness of HEART Pathway ADP implementation within a health system. This controlled before-after study will accrue adult patients with acute chest pain, but without ST-segment elevation myocardial infarction on electrocardiogram for two years and is expected to include approximately 10,000 patients. Outcomes measures include hospitalization rate, objective cardiac testing rates (stress testing and angiography), length of stay, and rates of recurrent cardiac care for participants. In pilot data, the HEART Pathway decreased hospitalizations by 21%, decreased hospital length (median of 12 hour reduction), without increasing adverse events or recurrent care. At the writing of this paper, data has been collected on >5000 patient encounters. The HEART Pathway has been fully integrated into health system electronic medical records, providing real-time decision support to our providers. We hypothesize that the HEART Pathway will safely reduce healthcare utilization. This study could provide a model for delivering high-value care to the 8-10 million US ED patients with acute chest pain each year. Clinicaltrials.gov NCT02056964; https://clinicaltrials.gov/ct2/show/NCT02056964 (Archived by WebCite at http://www.webcitation.org/6ccajsgyu).
Flame Tests Performed Safely: A Safe and Effective Alternative to the Traditional Flame Test
ERIC Educational Resources Information Center
Dogancay, Deborah
2005-01-01
The trend toward inquiry-based learning is providing today's students with a more enriching education. When implementing inquiry it is important to recognize the great number of safety concerns that accompany this paradigm shift. Fortunately, with some consideration, teachers can shape students' laboratory experiments into safe and valuable…
NASA Astrophysics Data System (ADS)
Andrianova, Olga; Lomakov, Gleb; Manturov, Gennady
2017-09-01
The report presents the results of an analysis of benchmark experiments form the international ICSBEP Handbook (HEU-MET-INTER-005) carried out at the the SSC RF - IPPE in cooperation with the Idaho National Laboratory (INL, USA) applicable to the verification of calculations of a wide range of tasks related to safe storage of vitrified radioactive waste. Experiments on the BFS assemblies make it possible to perform a large series of studies needed for neutron data refinement, including measurements of reactivity effects which allow testing the neutron cross section resonance structure. This series of studies is considered as a sample joint analysis framework for differential and integral experiments required to correct nuclea data files of the ROSFOND evaluated neutron data library. Thus, it is shown that despite the wide range of available experimental data, in so far as it relates to the resonance region refinement, the experiments on reactivity measurement make it possible to more subtly reflect the resonance structure peculiarities in addition to the time-of-flight measurement method.
Read your road : every highway user's guide to driving safely
DOT National Transportation Integrated Search
1993-11-01
This report is the sixth in a series produced for the Federal Transit Administration (FTA) and the Federal Highway Administration (FHWA) by the Volpe National Transportation Systems Center (Volpe Center). This formal comprehensive review of the plann...
SX-Ella Danis stent in massive upper gastrointestinal bleeding in cirrhosis - a case series.
Jain, Mayank; Balkrishanan, Mahadevan; Snk, Chenduran; Cgs, Sridhar; Ramakrishnan, Ravi; Venkataraman, Jayanthi
2018-06-01
We report our experience of three cases of decompensated cirrhosis with massive upper gastrointestinal bleeding, which required insertion of an SX-Ella Danis stent for hemostasis. The procedure is safe and effective.
Report: Information Security Series: Security Practices Safe Drinking Water Information System
Report #2006-P-00021, March 30, 2006. We found that the Office of Water (OW) substantially complied with many of the information security controls reviewed and had implemented practices to ensure production servers are monitored.
Topical Backgrounder: How Safe Am I? Helping Communities Evaluate Chemical Risks
Part of the May 1999 Guides to Environmental Risk Management Series created by the National Safety Council. Explains how RMPs will help prevent emergency chemical releases, reduce risk from exposure to hazards, and minimize consequences.
Goode, Travis D; Kim, Janice J; Maren, Stephen
2015-03-01
Aversive events can trigger relapse of extinguished fear memories, presenting a major challenge to the long-term efficacy of therapeutic interventions. Here, we examined factors regulating the relapse of extinguished fear after exposure of rats to a dangerous context. Rats received unsignaled shock in a distinct context ("dangerous" context) 24 h prior to auditory fear conditioning in another context. Fear to the auditory conditioned stimulus (CS) was subsequently extinguished either in the conditioning context ("ambiguous" context) or in a third novel context ("safe" context). Exposure to the dangerous context 30 min before a CS retention test caused relapse to the CS in the ambiguous and safe test contexts relative to nonextinguished controls. When rats were tested 24 h later (with or without short-term testing), rats tested in the ambiguous context continued to exhibit relapse, whereas rats tested in the safe context did not. Additionally, exposure of rats to the conditioning context--in place of the unsignaled shock context--did not result in relapse of fear to the CS in the safe testing context. Our work highlights the vulnerabilities of extinction recall to interference, and demonstrates the importance of context associations in the relapse of fear after extinction. © 2015 Goode et al.; Published by Cold Spring Harbor Laboratory Press.
Niu, Jun; Song, Wei; Yan, Ming; Fan, Wei; Niu, Weibo; Liu, Enyu; Peng, Cheng; Lin, Pengfei; Li, Peng; Khan, Abdul Qadir
2011-04-01
Transvaginal cholecystectomy has been performed successfully at several research institutions worldwide using natural orifice transluminal endoscopic surgery (NOTES) techniques. However, it is a growing new surgical concept in China. Several technical challenges hinder the safe clinical application of NOTES. This study investigated transvaginal endoscopic cholecystectomy performed with the assistance of a single umbilical trocar and achieved helpful initial clinical experience. From May 2009 to April 2010, a total of 43 transvaginal human cholecystectomies were performed. A single umbilical trocar was used for safe access and laparoscopic assistance during the operation. After the gallbladder had been removed through the vagina, the colpotomy was closed with absorbable stitches under direct vision. In addition, Student's t-test was performed for two samples to estimate the superiority of NOTES over a conventional laparoscopic cholecystectomy (LC) operation. The procedure was successfully completed for all the patients. No intra- or post-operative complications occurred. The patients recovered promptly after surgery, and all were satisfied with ideal cosmetic outcomes. The postoperative pain, hospital stay, and cost of hospitalization with NOTES were much less than with conventional LC operations. Although endoscopic instruments specifically designed for NOTES are not available, the addition of an umbilical trocar is an optimal way to allow safe performance of NOTES procedures in an easily reproducible manner. The authors' initial experience demonstrates that this hybrid technique is potentially feasible and effective for reducing postoperative pain and recovery times while improving the cosmetic results of transvaginal cholecystectomy.
Li, Lin-Feng; Guo, Jing; Wang, Jing
2004-07-01
Environmental contact factors in eczema were investigated in China by clinical questionnaire and patch testing patients with a modified European standard series of allergens. 217 consecutive eczema patients were studied. Contact dermatitis (CD) was clinically diagnosed in 30% of the patients. Among the patients patch tested, 46 patients had clinically diagnosed allergic CD (ACD), 20 patients clinically had non-ACD (NACD) (including 16 cases of irritant contact dermatitis, 1 case of phototoxic contact reaction and 3 cases of asteatotic eczema) and 115 patients had clinically suspected ACD. 45 patients (98%) in the ACD group went on to have relevant patch test results. The most common ACD was from metals, fragrance materials, cosmetics and rubber materials. The most common contact allergens identified were nickel, fragrance mix, para-phenylenediamine (PPD), carba mix and thimerosal. No adverse reactions were observed to patch testing, except for pruritus in patch-test-positive patients. The positive rate of patch testing in ACD was much higher than that in NACD (98% versus 15%, P < 0.05, chi(2)-test). 60 (28%) patients had facial dermatitis (FD). Among these, 20 (33%) were confirmed as having ACD. 48 (22%) patients had hand dermatitis (HD). Among these, 7 (15%) were confirmed as having ACD. Fewer patients were confirmed as having ACD in the HD group than in the FD (15% versus 33%, P < 0.05, chi(2)-test). Although the difference was not significant, the total positivity rate in the HD group (55%) was lower than in the other groups. 65 (30%) patients had unclassified endogenous eczema (UEE). The total positive rate of patch testing in the UEE group (56%) was no different from that in the FD or HD groups. However, the relevance of positive patch tests was hard to determine in UEE. These results indicate that CD is common in eczema; relatively more patients with FD have ACD, while other factors, such as irritation, may play more of a role in HD. The total positive rate of patch testing in the UEE group was no different from that in the FD or HD groups, suggesting that patch testing should be stressed in UEE and the relevance of positive patch test results in UEE should be studied further. It is effective and safe to patch eczema patients with a modified European standard series of allergens in China.
NASA Technical Reports Server (NTRS)
Crain, Timothy P.; Bishop, Robert H.; Carson, John M., III; Trawny, Nikolas; Hanak, Chad; Sullivan, Jacob; Christian, John; DeMars, Kyle; Campbell, Tom; Getchius, Joel
2016-01-01
The Morpheus Project began in late 2009 as an ambitious e ort code-named Project M to integrate three ongoing multi-center NASA technology developments: humanoid robotics, liquid oxygen/liquid methane (LOX/LCH4) propulsion and Autonomous Precision Landing and Hazard Avoidance Technology (ALHAT) into a single engineering demonstration mission to be own to the Moon by 2013. The humanoid robot e ort was redirected to a deploy- ment of Robonaut 2 on the International Space Station in February of 2011 while Morpheus continued as a terrestrial eld test project integrating the existing ALHAT Project's tech- nologies into a sub-orbital ight system using the world's rst LOX/LCH4 main propulsion and reaction control system fed from the same blowdown tanks. A series of 33 tethered tests with the Morpheus 1.0 vehicle and Morpheus 1.5 vehicle were conducted from April 2011 - December 2013 before successful, sustained free ights with the primary Vertical Testbed (VTB) navigation con guration began with Free Flight 3 on December 10, 2013. Over the course of the following 12 free ights and 3 tethered ights, components of the ALHAT navigation system were integrated into the Morpheus vehicle, operations, and ight control loop. The ALHAT navigation system was integrated and run concurrently with the VTB navigation system as a reference and fail-safe option in ight (see touchdown position esti- mate comparisons in Fig. 1). Flight testing completed with Free Flight 15 on December 15, 2014 with a completely autonomous Hazard Detection and Avoidance (HDA), integration of surface relative and Hazard Relative Navigation (HRN) measurements into the onboard dual-state inertial estimator Kalman lter software, and landing within 2 meters of the VTB GPS-based navigation solution at the safe landing site target. This paper describes the Mor- pheus joint VTB/ALHAT navigation architecture, the sensors utilized during the terrestrial ight campaign, issues resolved during testing, and the navigation results from the ight tests.
Orion Underway Recovery Test 5 (URT-5)
2016-10-26
A test version of the Orion crew module is secured in the well deck of the USS San Diego for Underway Recovery Test 5 in the Pacific Ocean off the coast of California. In view is the winch system that will be used to help retrieve the crew module during a series of tests in open waters. NASA's Ground Systems Development and Operations Program and the U.S. Navy will practice retrieving and securing the crew module in the well deck of the ship using a set of tethers and the winch system to prepare for recovery of Orion on its return from deep space missions. The testing will allow the team to demonstrate and evaluate recovery processes, procedures, hardware and personnel in open waters. Orion is the exploration spacecraft designed to carry astronauts to destinations not yet explored by humans, including an asteroid and NASA's Journey to Mars. It will have emergency abort capability, sustain the crew during space travel and provide safe re-entry from deep space return velocities. Orion is scheduled to launch on NASA's Space Launch System in late 2018. For more information, visit http://www.nasa.gov/orion.
Test Series 2. 4: detailed test plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Test Series 2.4 comprises the fourth sub-series of tests to be scheduled as a part of Test Series 2, the second stage of the combustion research program to be carried out at the Grimethorpe Experimental Pressurized Fluidized Bed Combustion Facility. Test Series 2.1, the first sub-series of tests, was completed in February 1983, and the first part of the second sub-series, Test Series 2.3, in October 1983. Test Series 2.2 was completed in February 1984 after which the second part of Test Series 2.3 commenced. The Plan for Test Series 2.4 consists of 350 data gathering hours to be completedmore » within 520 coal burning hours. This document provides a brief description of the Facility and modifications which have been made following the completion of Test Series 2.1. No further modifications were made following the completion of the first part of Test Series 2.3 or Test Series 2.2. The operating requirements for Test Series 2.4 are specified. The tests will be performed using a UK coal (Lady Windsor), and a UK limestone (Middleton) both nominated by the FRG. Seven objectives are proposed which are to be fulfilled by thirteen test conditions. Six part load tests based on input supplied by Kraftwerk Union AG are included. The cascade is expected to be on line for each test condition and total cascade exposure is expected to be in excess of 450 hours. Details of sampling and special measurements are given. A test plan schedule envisages the full test series being completed within a two month calendar period. Finally, a number of contingency strategies are proposed. 3 figures, 14 tables.« less
29 CFR 1915.15 - Maintenance of safe conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Enclosed Spaces and Other Dangerous Atmospheres in Shipyard Employment § 1915.15 Maintenance of safe... into spaces that have been certified “Safe for Workers” or “Safe for Hot Work” shall be disconnected... certificates. A competent person shall visually inspect and test each space certified as “Safe for Workers” or...
29 CFR 1915.15 - Maintenance of safe conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Enclosed Spaces and Other Dangerous Atmospheres in Shipyard Employment § 1915.15 Maintenance of safe... into spaces that have been certified “Safe for Workers” or “Safe for Hot Work” shall be disconnected... certificates. A competent person shall visually inspect and test each space certified as “Safe for Workers” or...
A ‘Simple Anterior Fish Excluder’ (SAFE) for Mitigating Penaeid-Trawl Bycatch
McHugh, Matthew J.; Broadhurst, Matt K.; Sterling, David J.; Millar, Russell B.
2015-01-01
Various plastic strips and sheets (termed ‘simple anterior fish excluders’−SAFEs) were positioned across the openings of penaeid trawls in attempts at reducing the unwanted bycatches of small teleosts. Initially, three SAFEs (a single wire without, and with small and large plastic panels) were compared against a control (no SAFE) on paired beam trawls. All SAFEs maintained targeted Metapenaeus macleayi catches, while the largest plastic SAFE significantly reduced total bycatch by 51% and the numbers of Pomatomus saltatrix, Mugil cephalus and Herklotsichthys castelnaui by up to 58%. A redesigned SAFE (‘continuous plastic’) was subsequently tested (against a control) on paired otter trawls, significantly reducing total bycatch by 28% and P. saltatrix and H. castelnaui by up to 42%. The continuous-plastic SAFE also significantly reduced M. macleayi catches by ~7%, but this was explained by ~5% less wing-end spread, and could be simply negated through otter-board refinement. Further work is required to refine the tested SAFEs, and to quantify species-specific escape mechanisms. Nevertheless, the SAFE concept might represent an effective approach for improving penaeid-trawl selectivity. PMID:25837892
Factors contributing to the retention of seated passengers during emergency stops
DOT National Transportation Integrated Search
1980-03-01
A series of seven experiments was conducted to examine the variables that : could contribute to a safe emergency stop on an automated guideway transit system. : Sixty subjects, conforming to a desired range, experienced emergency decelerations : in a...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stinson-Bagby, Kelly L.; Fielder, Robert S.; Van Dyke, Melissa K.
2004-02-04
The motivation for the reported research was to support NASA space nuclear power initiatives through the development of advanced fiber optic sensors for space-based nuclear power applications. Distributed high temperature measurements were made with 20 FBG temperature sensors installed in the SAFE-100 thermal simulator at the NASA Marshal Space Flight Center. Experiments were performed at temperatures approaching 800 deg. C and 1150 deg. C for characterization studies of the SAFE-100 core. Temperature profiles were successfully generated for the core during temperature increases and decreases. Related tests in the SAFE-100 successfully provided strain measurement data.
Physical and chemical test results of electrostatic safe flooring materials
NASA Technical Reports Server (NTRS)
Gompf, R. H.
1988-01-01
This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.
Autonomous Vehicle (AV) Safe Testing Regulations Arizona state agencies must support the testing fails, the vehicle must be brought to a complete stop or safe state. The Arizona Department of Public
NASA Technical Reports Server (NTRS)
Marshall, William M.; Borowski, Stanley K.; Bulman, Mel; Joyner, Russell; Martin, Charles R.
2015-01-01
Brief History of NTP: Project Rover Began in 1950s by Los Alamos Scientific Labs (now Los Alamos National Labs) and ran until 1970s Tested a series of nuclear reactor engines of varying size at Nevada Test Site (now Nevada National Security Site) Ranged in scale from 111 kN (25 klbf) to 1.1 MN (250 klbf) Included Nuclear Furnace-1 tests Demonstrated the viability and capability of a nuclear rocket engine test program One of Kennedys 4 goals during famous moon speech to Congress Nuclear Engines for Rocket Vehicle Applications (NERVA) Atomic Energy Commission and NASA joint venture started in 1964 Parallel effort to Project Rover was focused on technology demonstration Tested XE engine, a 245-kN (55-klbf) engine to demonstrate startup shutdown sequencing. Hot-hydrogen stream is passed directly through fuel elements potential for radioactive material to be eroded into gaseous fuel flow as identified in previous programs NERVA and Project Rover (1950s-70s) were able to test in open atmosphere similar to conventional rocket engine test stands today Nuclear Furance-1 tests employed a full scrubber system Increased government and environmental regulations prohibit the modern testing in open atmosphere. Since the 1960s, there has been an increasing cessation on open air testing of nuclear material Political and national security concerns further compound the regulatory environment
Environmental Control and Life Support Systems Testing Facility at MSFC
NASA Technical Reports Server (NTRS)
2001-01-01
The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. This photograph shows the Urine Processor Assembly (UPA) which utilizes the Vapor Compression Distillation (VCD) technology. The VCD is used for integrated testing of the entire Water Recovery System (WRS) and development testing of the Urine Processor Assembly. The UPA accepts and processes pretreated crewmember urine to allow it to be processed along with other wastewaters in the Water Processor Assembly (WPA). The WPA removes free gas, organic, and nonorganic constituents before the water goes through a series of multifiltration beds for further purification. Product water quality is monitored primarily through conductivity measurements. Unacceptable water is sent back through the WPA for reprocessing. Clean water is sent to a storage tank.
Kinetic-energy absorber employs frictional force between mating cylinders
NASA Technical Reports Server (NTRS)
Conrad, E. W.
1964-01-01
A kinetic energy absorbing device uses a series of coaxial, mating cylindrical surfaces. These surfaces have high frictional resistance to relative motion when axial impact forces are applied. The device is designed for safe deceleration of vehicles impacting on landing surfaces.
UAS-NAS Integrated Human in the Loop: Test Environment Report
NASA Technical Reports Server (NTRS)
Murphy, Jim; Otto, Neil; Jovic, Srba
2015-01-01
The desire and ability to fly Unmanned Aircraft Systems (UAS) in the National Airspace System (NAS) is of increasing urgency. The application of unmanned aircraft to perform national security, defense, scientific, and emergency management are driving the critical need for less restrictive access by UAS to the NAS. UAS represent a new capability that will provide a variety of services in the government (public) and commercial (civil) aviation sectors. The growth of this potential industry has not yet been realized due to the lack of a common understanding of what is required to safely operate UAS in the NAS. NASA's UAS Integration in the NAS Project is conducting research in the areas of Separation Assurance/Sense and Avoid Interoperability (SSI), Human Systems Integration (HSI), and Communication to support reducing the barriers of UAS access to the NAS. This research was broken into two research themes namely, UAS Integration and Test Infrastructure. UAS Integration focuses on airspace integration procedures and performance standards to enable UAS integration in the air transportation system, covering Sense and Avoid (SAA) performance standards, command and control performance standards, and human systems integration. The focus of the Test Infrastructure theme was to enable development and validation of airspace integration procedures and performance standards, including the execution of integrated test and evaluation. In support of the integrated test and evaluation efforts, the Project developed an adaptable, scalable, and schedulable relevant test environment incorporating live, virtual, and constructive elements capable of validating concepts and technologies for unmanned aircraft systems to safely operate in the NAS. To accomplish this task, the Project planned to conduct three integrated events: a Human-in-the-Loop simulation and two Flight Test series that integrated key concepts, technologies and/or procedures in a relevant air traffic environment. Each of the integrated events were built on the technical achievements, fidelity and complexity of previous simulations and tests, resulting in research findings that support the development of regulations governing the access of UAS into the NAS. The purpose of this document is to describe how well the system under test was representative
Pyrrolidine-Acridine hybrid in Artemisinin-based combination: a pharmacodynamic study.
Pandey, Swaroop Kumar; Biswas, Subhasish; Gunjan, Sarika; Chauhan, Bhavana Singh; Singh, Sunil Kumar; Srivastava, Kumkum; Singh, Sarika; Batra, Sanjay; Tripathi, Renu
2016-09-01
Aiming to develop new artemisinin-based combination therapy (ACT) for malaria, antimalarial effect of a new series of pyrrolidine-acridine hybrid in combination with artemisinin derivatives was investigated. Synthesis, antimalarial and cytotoxic evaluation of a series of hybrid of 2-(3-(substitutedbenzyl)pyrrolidin-1-yl)alkanamines and acridine were performed and mode of action of the lead compound was investigated. In vivo pharmacodynamic properties (parasite clearance time, parasite reduction ratio, dose and regimen determination) against multidrug resistant (MDR) rodent malaria parasite and toxicological parameters (median lethal dose, liver function test, kidney function test) were also investigated. 6-Chloro-N-(4-(3-(3,4-dimethoxybenzyl)pyrrolidin-1-yl)butyl)-2-methoxyacridin-9-amine (15c) has shown a dose dependent haem bio-mineralization inhibition and was found to be the most effective and safe compound against MDR malaria parasite in Swiss mice model. It displayed best antimalarial potential with artemether (AM) in vitro as well as in vivo. The combination also showed favourable pharmacodynamic properties and therapeutic response in mice with established MDR malaria infection and all mice were cured at the determined doses. The combination did not show toxicity at the doses administered to the Swiss mice. Taken together, our findings suggest that compound 15c is a potential partner with AM for the ACT and could be explored for further development.
Toward an Improved Hypersonic Engine Seal
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; DeMange,Jeffrey J.; Taylor, Shawn C.
2003-01-01
High temperature, dynamic seals are required in advanced engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures from 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA s Glenn Research Center (GRC) is developing advanced seals to overcome these shortfalls. Two seal designs and two types of seal preloading devices were evaluated in a series of compression tests at room temperature and 2000 F and flow tests at room temperature. Both seals lost resiliency with repeated load cycling at room temperature and 2000 F, but seals with braided cores were significantly more flexible than those with cores composed of uniaxial ceramic fibers. Flow rates for the seals with cores of uniaxial fibers were lower than those for the seals with braided cores. Canted coil springs and silicon nitride compression springs showed promise conceptually as potential seal preloading devices to help maintain seal resiliency.
Doppler Lidar Sensor for Precision Landing on the Moon and Mars
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin; Petway, Larry; Hines, Glenn; Barnes, Bruce; Pierrottet, Diego; Lockhard, George
2012-01-01
Landing mission concepts that are being developed for exploration of planetary bodies are increasingly ambitious in their implementations and objectives. Most of these missions require accurate position and velocity data during their descent phase in order to ensure safe soft landing at the pre-designated sites. To address this need, a Doppler lidar is being developed by NASA under the Autonomous Landing and Hazard Avoidance (ALHAT) project. This lidar sensor is a versatile instrument capable of providing precision velocity vectors, vehicle ground relative altitude, and attitude. The capabilities of this advanced technology have been demonstrated through two helicopter flight test campaigns conducted over a vegetation-free terrain in 2008 and 2010. Presently, a prototype version of this sensor is being assembled for integration into a rocket-powered terrestrial free-flyer vehicle. Operating in a closed loop with vehicle's guidance and navigation system, the viability of this advanced sensor for future landing missions will be demonstrated through a series of flight tests in 2012.
Automated Microbial Metabolism Laboratory
NASA Technical Reports Server (NTRS)
1972-01-01
The Automated Microbial Metabolism Laboratory (AMML) 1971-1972 program involved the investigation of three separate life detection schemes. The first was a continued further development of the labeled release experiment. The possibility of chamber reuse without inbetween sterilization, to provide comparative biochemical information was tested. Findings show that individual substrates or concentrations of antimetabolites may be sequentially added to a single test chamber. The second detection system which was investigated for possible inclusion in the AMML package of assays, was nitrogen fixation as detected by acetylene reduction. Thirdly, a series of preliminary steps were taken to investigate the feasibility of detecting biopolymers in soil. A strategy for the safe return to Earth of a Mars sample prior to manned landings on Mars is outlined. The program assumes that the probability of indigenous life on Mars is unity and then broadly presents the procedures for acquisition and analysis of the Mars sample in a manner to satisfy the scientific community and the public that adequate safeguards are being taken.
Kuo, Chao-Yin; Lin, Yuan-Yung
2017-01-01
Objectives. The primary objective for this study is to evaluate the advantages, disadvantages, surgical applicability, and outcome of the pulsed electron avalanche knife (PEAK) PlasmaBlade in transoral adenoidectomy under direct visualization using video nasoendoscopy. Patients and Methods. In this series, six cases of adenoid hypertrophy showing varying clinical presentations in relation to its clinical course were surgically treated using a PEAK PlasmaBlade. Before and after surgery, all patients underwent nasal endoscopy to define the grading of hypertrophic adenoids and postoperative outcome. Pure tone audiometry and tympanometry tests were carried out to investigate the change in middle and inner ear functions. Results. The mean follow-up period was 23.8 months. Postoperatively, symptoms of otitis media with effusion were all relieved with closure of the air-bone gap (6/6). Other relevant ear complaints like tinnitus were resolved (1/1) and aural fullness disappeared in 87.5% of ears (7/8). Nasal obstruction (2/2) and postnasal drip (2/2) were improved after surgery. Conclusions. Based on this preliminary report of a case series in a limited sample size, we suggest that using the transoral PEAK PlasmaBlade for adenoidectomy guided by video nasoendoscopy is a safe and feasible surgical technique, allowing remarkable outcomes by providing precise tissue removal, effective hemostasis, and painless postoperative recovery. PMID:28459055
Evaluating the effectiveness of biometric access control systems
NASA Astrophysics Data System (ADS)
Lively, Valerie M.
2005-05-01
This paper describes the contribution by the National Safe Skies Alliance (Safe Skies) in operational testing of biometric access control systems under the guidance of the Transportation Security Administration (TSA). Safe Skies has been conducting operational tests of biometric access control systems on behalf of the TSA for approximately four years. The majority of this testing has occurred at the McGhee Tyson Airport (TYS) in Knoxville, Tennessee. Twelve separate biometric devices - eight fingerprint, facial, iris, hand geometry, and fingerprint and iris, have been tested to date. Tests were conducted at a TYS administrative door and different airports to evaluate the access control device under normal, abnormal, and attempt-to-defeat conditions.
Community design and the incidence of crashes involving pedestrians and motorists aged 75 and older.
DOT National Transportation Integrated Search
2012-04-01
Contemporary community design practice has focused on strategies intended to make communities safe for families with children. Comparatively little attention has been given to its effects on older adults. This study employs a series of negative binom...
Drug impaired Driving : Understanding the Problem and Ways to Reduce It (a Report to Congress)
DOT National Transportation Integrated Search
2009-12-01
This report was prepared in accordance with Section 2013 of the Safe, Accountable, Flexible, Efficient : Transportation Equity Act: A Legacy for Users (SAFETEA-LU). The report summarizes a series of studies : undertaken by the National Highway Traffi...
Standards and Practices in Outdoor Activities.
ERIC Educational Resources Information Center
Robertson, Stuart, Ed.
The guide provides a series of checklists and guidelines to assist Quebec outdoor education teachers and/or leaders and their principals in planning safe, enjoyable, educational experiences for elementary and secondary school students. The basic planning checklist itemizes specific tasks under eight categories: (1) preliminary discussion with…
Dual Kidney Transplantation: Evaluation of Recipient Selection Criteria at Niguarda Hospital.
Mariani, A; Ferla, F; De Carlis, R; Rossetti, O; Covucci, E; Tripepi, M; Concone, G; Lauterio, A; Mangoni, I; De Carlis, L
2016-03-01
Dual kidney transplantation (DKT) is a largely accepted strategy to enlarge the donor pool. Niguarda Hospital started this program in December 2010, and 38 DKT have been performed. In our series, we included recipients older than those in the other series published in literature. The aim of this study was to know if our recipient selection criteria for DKT are safe. We reviewed our data base of DKT and analyzed recipients' medical history, surgical technique, post-operative complications, graft survival, morbidity, and mortality. We then compared our results with the literature. From December 2010 to April 2015, 38 DKT were performed in Niguarda Hospital. Delayed graft function was present in 21 recipients. Explantation of both kidneys was performed in 1 patient and explantation of 1 kidney in 6 patients. Post-operative complications were present in 8 patients. Five patients returned to hemodialysis after DKT. One recipient died of medical post-operative sepsis. The mean follow-up was 24 months. Graft survival and patient survival were 86.84% and 97.93%, respectively. Compared with the literature, our series had similar mortality and morbidity rates, even if recipients' age was higher than in other series. The strategy of DKT allocation in elderly recipients is safe. Further studies have to be performed to optimized selection of the recipients for DKT not to disadvantage younger patients in the transplant waiting list and to improve the technique of organ evaluation and preservation to refine graft allocation. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Schulze, Norman R.; Maxfield, B.; Boucher, C.
1995-01-01
Solid State Laser Initiated Ordnance (LIO) offers new technology having potential for enhanced safety, reduced costs, and improved operational efficiency. Concerns over the absence of programmatic applications of the technology, which has prevented acceptance by flight programs, should be abated since LIO has now been operationally implemented by the Laser Initiated Ordnance Sounding Rocket Demonstration (LOSRD) Program. The first launch of solid state laser diode LIO at the NASA Wallops Flight Facility (WFF) occurred on March 15, 1995 with all mission objectives accomplished. This project, Phase 3 of a series of three NASA Headquarters LIO demonstration initiatives, accomplished its objective by the flight of a dedicated, all-LIO sounding rocket mission using a two-stage Nike-Orion launch vehicle. LIO flight hardware, made by The Ensign-Bickford Company under NASA's first Cooperative Agreement with Profit Making Organizations, safely initiated three demanding pyrotechnic sequence events, namely, solid rocket motor ignition from the ground and in flight, and flight termination, i.e., as a Flight Termination System (FTS). A flight LIO system was designed, built, tested, and flown to support the objectives of quickly and inexpensively putting LIO through ground and flight operational paces. The hardware was fully qualified for this mission, including component testing as well as a full-scale system test. The launch accomplished all mission objectives in less than 11 months from proposal receipt. This paper concentrates on accomplishments of the ordnance aspects of the program and on the program's implementation and results. While this program does not generically qualify LIO for all applications, it demonstrated the safety, technical, and operational feasibility of those two most demanding applications, using an all solid state safe and arm system in critical flight applications.
Test Series 2. 2: Detailed Test Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Test Series 2.2 comprises the third sub-series of tests to be scheduled as a part of Test Series 2, the second stage of the combustion research program to be carried out at the Grimethorpe Experimental Pressurized Fluidized Bed Combustion Facility. Test Series 2.1, the first sub-series of tests, was completed in February 1983, and the first half of the second sub-series, Test Series 2.3, in October 1983. Test Series 2.2 is to consist of 350 data gathering hours, which it is hoped to complete within 560 coal burning hours. This document provides a brief description of the Facility and modificationsmore » which have been made following the completion of Test Series 2.1. No further modifications were made following the completion of the first half of Test Series 2.3. The operating requirements are specified. The tests will be performed using a UK coal (Kiveton Park), and a UK limestone (Middleton) both nominated by the FRG. Nine objectives are proposed which are to be fulfilled by thirteen test conditions. Six part load tests are included, as defined by Kraftwerk Union AG. The cascade is expected to be on line for each test condition and total cascade exposure is expected to be in excess of 450 hours. Details of sampling and special measurements are given. A test plan schedule envisages the test series being completed within a two month calendar period. Finally, a number of contingency strategies are proposed.« less
Hunter Education: Student Manual. Shooting Skills Series.
ERIC Educational Resources Information Center
Staton, Robert D., Jr.
Designed for use in a hunter education course or as a self-teaching workbook, the student manual presents the following topics: an overall picture including firearms accidents and hunter education; firearms and ammunition; hunting tradition and ethics; the hunter and conservation; safe firearms handling; hunter responsibilities; hunter…
The Future of Aircraft Paint Removal Methods
1989-09-01
barium, cadmium, chromium, lead, mercury , selenium, and silver. We must develop small efficient blast furnaces to burn the media thus reducing the...permit the safe collection, consolidation, and detoxication of stripping waste. This may be as simple as a series of filters to clean the air from
Safety in Science. Curriculum Support Series.
ERIC Educational Resources Information Center
Lulashnyk, Lorne; Boonov, Janet
Since the major causes of accidents are carelessness and a negative or apathetic attitude towards safety, this guide was developed to facilitate safe, stimulating science laboratory activities by providing both general and specific safety information presented in 12 sections. Subject areas considered in these sections include: 1)…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellison, M.
2008-07-01
Retrieval of sludge and fuel from the First Generation Magnox Fuel Storage Pond, and its safe long term storage is one of the NDA's top priorities in the UK clean up programme. The plant is currently undergoing a series of major modifications in preparation for the retrievals operations. The most visible example of these modifications is the Gantry Refurbishment System (GRS), a major work platform which has recently been lifted onto the pond long travel girders used by the Skip Handler. This paper describes the design, manufacture, works test, and site installation of this major piece of equipment. The installationmore » lift, involving the use of an 800Te crane was one of the largest lifts undertaken at Sellafield. The GRS is a mobile platform structure which is designed to be pushed or pulled along the long travel girders by the Skip Handler. Its principle function is to provide a safe and shielded working platform from which to undertake refurbishment of the Skip Handler long travel girders and support structure. The potential hazards and consequences resulting from the modification were fully understood and controls were put in place to ensure that the risk of carrying out the work was as low as reasonably practicable. The work was authorised by the NII, Sellafield Nuclear Safety Committee and an independent readiness review panel. Despite less than perfect weather in the run up to the lift, the GRS was successfully and safely lifted onto the pond on 18 October 2006, the culmination of three years of planning, engineering and construction. (authors)« less
Development of a tornado safe room door from wood Products: door design and impact testing
Robert H. Falk; James J. Bridwell
2016-01-01
In this study, a tornado safe room door built from wood products and steel sheeting was developed and impact-tested according to tornado safe room standards. Results indicate that an door constructed from as few as two sheets of 23/32-in. (18.26-mm) construction-grade plywood and overlaid with 18-gauge (0.05-in.- (1.27- mm-) thick) steel can pass the required impact...
Vrkljan, Brenda H; Cranney, Ann; Worswick, Julia; O'Donnell, Siobhan; Li, Linda C; Gélinas, Isabelle; Byszewski, Anna; Man-Son-Hing, Malcolm; Marshall, Shawn
2010-01-01
We conducted a series of focus groups to explore the information needs of clinicians and consumers related to arthritis and driving. An open coding analysis identified common themes across both consumer and clinician-based focus groups that underscored the importance of addressing driving-related concerns and the challenges associated with assessing safety. The results revealed that although driving is critical for maintaining independence and community mobility, drivers with arthritis experience several problems that can affect safe operation of a motor vehicle. Findings from this study are part of a broader research initiative that will inform the development of the Arthritis and Driving toolkit. This toolkit outlines strategies to support safe mobility for people with arthritis and will be an important resource in the coming years given the aging population.
Safety of liposuction using exclusively tumescent local anesthesia in 3,240 consecutive cases.
Habbema, Louis
2009-11-01
Many surgeons consider liposuction using tumescent local anesthesia (TLA) to be a safe technique, but when TLA has been combined with other techniques, such as general anesthesia or intravenous medication, or when the guidelines associated with TLA have been violated, serious complications and deaths have occurred. This has resulted in uncertainty concerning the safety of liposuction using TLA, which this article seeks to resolve. To investigate whether liposuction using TLA is a safe procedure. The same surgeon performed liposuction using exclusively TLA in 3,240 procedures. Detailed records were kept of the complications that occurred. In a series of 3,240 procedures, no deaths occurred, and no complications requiring hospitalization were experienced. In nine cases, complications developed that needed further action. Liposuction using exclusively TLA is a proven safe procedure provided that the existing guidelines are meticulously followed.
NASA Technical Reports Server (NTRS)
Iannicca, Dennis C.; McKim, James H.; Stewart, David H.; Thadhani, Suresh K.; Young, Daniel P.
2015-01-01
NASA Glenn Research Center, in cooperation with Rockwell Collins, is working to develop a prototype Control and Non-Payload Communications (CNPC) radio platform as part of NASA Integrated Systems Research Program's (ISRP) Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) project. A primary focus of the project is to work with the FAA and industry standards bodies to build and demonstrate a safe, secure, and efficient CNPC architecture that can be used by industry to evaluate the feasibility of deploying a system using these technologies in an operational capacity. GRC has been working in conjunction with these groups to assess threats, identify security requirements, and to develop a system of standards-based security controls that can be applied to the current GRC prototype CNPC architecture as a demonstration platform. The security controls were integrated into a lab test bed mock-up of the Mobile IPv6 architecture currently being used for NASA flight testing, and a series of network tests were conducted to evaluate the security overhead of the controls compared to the baseline CNPC link without any security. The aim of testing was to evaluate the performance impact of the additional security control overhead when added to the Mobile IPv6 architecture in various modes of operation. The statistics collected included packet captures at points along the path to gauge packet size as the sample data traversed the CNPC network, round trip latency, jitter, and throughput. The effort involved a series of tests of the baseline link, a link with Robust Header Compression (ROHC) and without security controls, a link with security controls and without ROHC, and finally a link with both ROHC and security controls enabled. The effort demonstrated that ROHC is both desirable and necessary to offset the additional expected overhead of applying security controls to the CNPC link.
Familoni, Babajide O; Gregor, Kristin L; Dodson, Thomas S; Krzywicki, Alan T; Lowery, Bobby N; Orr, Scott P; Suvak, Michael K; Rasmusson, Ann M
2016-09-01
Stress analysis by FLIR (forward-looking infrared) evaluation (SAFE) has been demonstrated to monitor sweat pore activation (SPA) as a novel surrogate measure of sympathetic nervous system (SNS) activity in a normal population. SNS responses to a series of 15 1-s, 82 dB, white noise bursts were measured by skin conductance (SC) and SAFE monitoring of SPA on the fingers (FiP) and face (FaP) in 10 participants with posttraumatic stress disorder (PTSD) and 16 trauma-exposed participants without PTSD (Mage = 48.92 ± 12.00 years; 26.9% female). Within participants, SC and FiP responses across trials were strongly correlated (r = .92, p < .001). Correlations between SC and FaP (r = .76, p = .001) and between FiP and FaP (r = .47, p = .005) were smaller. The habituation of SNS responses across the 15 trials was substantial (SC: d = -2.97; FiP: d = -2.34; FaP: d = -1.02). There was a strong correlation between habituation effects for SC and FiP (r = .76, p < .001), but not for SC and FaP (r = .15, p = .45) or FiP and FaP (r = .29, p = .16). Participants with PTSD showed larger SNS responses to the first loud noise than those without PTSD. PTSD reexperiencing symptoms assessed by the PTSD Checklist on the day of testing were associated with the SNS responses to the first loud noise measured by SC (d = 1.19) and FiP (d = .99), but not FaP (d = .10). This study confirms convergence of SAFE and SC as valid measures of SNS activity. SAFE FiP and SC responses were highly predictive of self-rated PTSD reexperiencing symptoms. SAFE may offer an attractive alternative for applications in PTSD and similar populations. © 2016 Society for Psychophysiological Research. This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Reirradiation spine stereotactic body radiation therapy for spinal metastases: systematic review.
Myrehaug, Sten; Sahgal, Arjun; Hayashi, Motohiro; Levivier, Marc; Ma, Lijun; Martinez, Roberto; Paddick, Ian; Régis, Jean; Ryu, Samuel; Slotman, Ben; De Salles, Antonio
2017-10-01
OBJECTIVE Spinal metastases that recur after conventional palliative radiotherapy have historically been difficult to manage due to concerns of spinal cord toxicity in the retreatment setting. Spine stereotactic body radiation therapy (SBRT), also known as stereotactic radiosurgery, is emerging as an effective and safe means of delivering ablative doses to these recurrent tumors. The authors performed a systematic review of the literature to determine the clinical efficacy and safety of spine SBRT specific to previously irradiated spinal metastases. METHODS A systematic literature review was conducted, which was specific to SBRT to the spine, using MEDLINE, Embase, Cochrane Evidence-Based Medicine Database, National Guideline Clearinghouse, and CMA Infobase, with further bibliographic review of appropriate articles. Research questions included: 1) Is retreatment spine SBRT efficacious with respect to local control and symptom control? 2) Is retreatment spine SBRT safe? RESULTS The initial literature search retrieved 2263 articles. Of these articles, 160 were potentially relevant, 105 were selected for in-depth review, and 9 studies met all inclusion criteria for analysis. All studies were single-institution series, including 4 retrospective, 3 retrospective series of prospective databases, 1 prospective, and 1 Phase I/II prospective study (low- or very low-quality data). The results indicated that spine SBRT is effective, with a median 1-year local control rate of 76% (range 66%-90%). Improvement in patients' pain scores post-SBRT ranged from 65% to 81%. Treatment delivery was safe, with crude rates of vertebral body fracture of 12% (range 0%-22%) and radiation-induced myelopathy of 1.2%. CONCLUSIONS This systematic literature review suggests that SBRT to previously irradiated spinal metastases is safe and effective with respect to both local control and pain relief. Although the evidence is limited to low-quality data, SBRT can be a recommended treatment option for reirradiation.
TECHNOLOGIES FOR UPGRADING EXISTING OR DESIGNING NEW DRINKING WATER TREATMENT FACILITIES
The publication compiles material presented at a series of workshops and helps to focus attention on the many treatment and disinfection decisions that will be facing both ground water and surface source systems over the next several years, as implementation of the 1986 Safe Drin...
Hunter Education: Instructor Manual. Shooting Skills Series.
ERIC Educational Resources Information Center
Diebold, Louis, Comp.; And Others
Composed of three books (a procedures guide, the basic student manual, and lesson plans), the instructor's manual provides information to set up and conduct a Hunter Education Certification Course. Course topics include: an introduction, firearms and ammunition, hunting tradition and ethics, the hunter and conservation, safe firearms handling,…
Department of Labor Issues. Transition Series.
ERIC Educational Resources Information Center
Comptroller General of the U.S., Washington, DC.
The Secretary of Labor should place emphasis on five issues to ensure safe and healthful workplaces and to promote the welfare of wage earners. First, the Secretary should improve the Occupational Safety and Health Administration's enforcement program. Second, the Secretary should enhance the use of Job Training Partnership Act resources. Third,…
Safety in Team Sports. Sports Safety Series, Monograph No. 3.
ERIC Educational Resources Information Center
Borozne, Joseph, Ed.; And Others
This monograph examines methods of promoting safe practices in the conduct of selected team sports with the aim of reducing and eliminating the occurrance of injuries. The team sports discussed are baseball and softball, basketball, field hockey, tackle football, touch and flag football, ice hockey, lacrosse, and soccer. (MJB)
Backpacking. Outdoor Living Skills Series. Instructor Manual.
ERIC Educational Resources Information Center
Mentis, Jim
Intended for use by those who teach or work with youth in classroom or organizational settings, this self-contained module is designed to teach novices how to prepare for and conduct a safe backpack trip. Initial chapters present background information under nine headings: introduction (objectives, backpack history, information about Missouri…
ERIC Educational Resources Information Center
Moeller, James L.
1996-01-01
The second of a two-part series on contraindications to athletic activity, this article examines the sensory, spinal, gastrointestinal, systemic, hematologic, and dermatologic conditions that warrant activity disqualification and provides guidelines about when it is safe to participate. Activity considerations for individuals who have lost a…
How to Handle Radioisotopes Safely.
ERIC Educational Resources Information Center
Sulcoski, John W.
This booklet is one in a series of instructional aids designed for use by elementary and secondary school science teachers. The various units and forms of radioactive materials used by teachers are first considered. Then, the quantities of radioisotopes that a person may possess without a license from the Atomic Energy Commission (AEC) are…
Reporting School Violence. Legal Series Bulletin.
ERIC Educational Resources Information Center
Department of Justice, Washington, DC. Office of Justice Programs.
Violence and crime in schools affect students and their families, school employees and administrators, law enforcement and criminal justice officials, policymakers, and communities. Enactment of strong, concise school violence reporting laws is a crucial first step on the road to making schools safe and violence free. This bulletin provides an…
78 FR 68735 - Reduction or Suspension of Safe Harbor Contributions
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... forth in section 401(k)(3), called the actual deferral percentage (ADP) test, or one of the design-based... design-based safe harbor method under which a CODA is treated as satisfying the ADP test if the... the design-based alternatives in section 401(m)(10), 401(m)(11), or 401(m)(12). The ACP test in...
Helicopter pilot estimation of self-altitude in a degraded visual environment
NASA Astrophysics Data System (ADS)
Crowley, John S.; Haworth, Loran A.; Szoboszlay, Zoltan P.; Lee, Alan G.
2000-06-01
The effect of night vision devices and degraded visual imagery on self-attitude perception is unknown. Thirteen Army aviators with normal vision flew five flights under various visual conditions in a modified AH-1 (Cobra) helicopter. Subjects estimated their altitude or flew to specified altitudes while flying a series of maneuvers. The results showed that subjects were better at detecting and controlling changes in altitude than they were at flying to or naming a specific altitude. In cruise flight and descent, the subjects tended to fly above the desired altitude, an error in the safe direction. While hovering, the direction of error was less predictable. In the low-level cruise flight scenario tested in this study, altitude perception was affected more by changes in image resolution than by changes in FOV or ocularity.
SafeTrip-21 : Federal ITS field tests to transform the traveler experience.
DOT National Transportation Integrated Search
2011-06-30
SafeTrip-21 popularized transportation technology by making traffic and transit data available to the public via websites, smartphone apps, and other electronic media. Federal ITS field tests were carried out between November 2008 and November 2010 i...
NASA Technical Reports Server (NTRS)
Kopardekar, Parimal H.
2016-01-01
Unmanned Aircraft System (UAS) Traffic Management (UTM) Enabling Civilian Low-Altitude Airspace and Unmanned Aircraft System Operations What is the problem? Many beneficial civilian applications of UAS have been proposed, from goods delivery and infrastructure surveillance, to search and rescue, and agricultural monitoring. Currently, there is no established infrastructure to enable and safely manage the widespread use of low-altitude airspace and UAS operations, regardless of the type of UAS. A UAS traffic management (UTM) system for low-altitude airspace may be needed, perhaps leveraging concepts from the system of roads, lanes, stop signs, rules and lights that govern vehicles on the ground today, whether the vehicles are driven by humans or are automated. What system technologies is NASA exploring? Building on its legacy of work in air traffic management for crewed aircraft, NASA is researching prototype technologies for a UAS Traffic Management (UTM) system that could develop airspace integration requirements for enabling safe, efficient low-altitude operations. While incorporating lessons learned from the today's well-established air traffic management system, which was a response that grew out of a mid-air collision over the Grand Canyon in the early days of commercial aviation, the UTM system would enable safe and efficient low-altitude airspace operations by providing services such as airspace design, corridors, dynamic geofencing, severe weather and wind avoidance, congestion management, terrain avoidance, route planning and re-routing, separation management, sequencing and spacing, and contingency management. One of the attributes of the UTM system is that it would not require human operators to monitor every vehicle continuously. The system could provide to human managers the data to make strategic decisions related to initiation, continuation, and termination of airspace operations. This approach would ensure that only authenticated UAS could operate in the airspace. In its most mature form, the UTM system could be developed using autonomicity characteristics that include self-configuration, self-optimization and self-protection. The self-configuration aspect could determine whether the operations should continue given the current andor predicted windweather conditions. NASA envisions concepts for two types of possible UTM systems. The first type would be a Portable UTM system, which would move from between geographical areas and support operations such as precision agriculture and disaster relief. The second type of system would be a Persistent UTM system, which would support low-altitude operations and provide continuous coverage for a geographical area. Either system would require persistent communication, navigation, and surveillance (CNS) coverage to track, ensure, and monitor conformance. What is NASA doing to test the technologies? NASA's near-term goal is the development and demonstration of a possible future UTM system that could safely enable low-altitude airspace and UAS operations. Working alongside many committed government, industry and academic partners, NASA is leading the research, development and testing that is taking place in a series of activities called Technology Capability Levels (TCL), each increasing in complexity. UTM TCL1 concluded field testing in August 2015 and is undergoing additional testing at an FAA site.
Goode, Travis D.; Kim, Janice J.
2015-01-01
Aversive events can trigger relapse of extinguished fear memories, presenting a major challenge to the long-term efficacy of therapeutic interventions. Here, we examined factors regulating the relapse of extinguished fear after exposure of rats to a dangerous context. Rats received unsignaled shock in a distinct context (“dangerous” context) 24 h prior to auditory fear conditioning in another context. Fear to the auditory conditioned stimulus (CS) was subsequently extinguished either in the conditioning context (“ambiguous” context) or in a third novel context (“safe” context). Exposure to the dangerous context 30 min before a CS retention test caused relapse to the CS in the ambiguous and safe test contexts relative to nonextinguished controls. When rats were tested 24 h later (with or without short-term testing), rats tested in the ambiguous context continued to exhibit relapse, whereas rats tested in the safe context did not. Additionally, exposure of rats to the conditioning context—in place of the unsignaled shock context—did not result in relapse of fear to the CS in the safe testing context. Our work highlights the vulnerabilities of extinction recall to interference, and demonstrates the importance of context associations in the relapse of fear after extinction. PMID:25691517
Behavioral Determinants of Switching to Arsenic-Safe Water Wells.
George, Christine Marie; Inauen, Jennifer; Perin, Jamie; Tighe, Jennifer; Hasan, Khaled; Zheng, Yan
2017-02-01
More than 100 million people globally are estimated to be exposed to arsenic in drinking water that exceeds the World Health Organization guideline of 10 µg/L. In an effort to develop and test a low-cost sustainable approach for water arsenic testing in Bangladesh, we conducted a randomized controlled trial which found arsenic educational interventions when combined with fee-based water arsenic testing programs led to nearly all households buying an arsenic test for their drinking water sources (93%) compared with only 53% when fee-based arsenic testing alone was offered. The aim of the present study was to build on the findings of this trial by investigating prospectively the psychological factors that were most strongly associated with switching to arsenic-safe wells in response to these interventions. Our theoretical framework was the RANAS (risk, attitude, norm, ability, and self-regulation) model of behavior change. In the multivariate logistic regression model of 285 baseline unsafe well users, switching to an arsenic-safe water source was significantly associated with increased instrumental attitude (odds ratio [OR] = 9.12; 95% confidence interval [CI] = [1.85, 45.00]), descriptive norm (OR = 34.02; 95% CI = [6.11, 189.45]), coping planning (OR = 11.59; 95% CI = [3.82, 35.19]), and commitment (OR = 10.78; 95% CI = [2.33, 49.99]). In addition, each additional minute from the nearest arsenic-safe drinking water source reduced the odds of switching to an arsenic-safe well by more than 10% (OR = 0.89; 95% CI = [0.87, 0.92]). Future arsenic mitigation programs should target these behavioral determinants of switching to arsenic-safe water sources.
Naito, Masanori; Miura, Hirohisa; Nakamura, Takatoshi; Sato, Takeo; Yamanashi, Takahiro; Tsutsui, Atsuko; Watanabe, Masahiko
2017-05-01
Gastrointestinal anastomosis remains associated with a considerable burden of morbidity and, in some cases, mortality. Functional end-to-end anastomosis, whilst extremely efficient, is vulnerable to increased intestinal pressure in the immediate postoperative period, which may predispose to development of anastomotic leakage or bleeding. Therefore, there is a requirement for new techniques that facilitate safe and efficacious anastomotic procedures. This study examined the clinical application of functional end-to-end anastomosis with a stapler that automatically applies a bioabsorbable polyglycolic acid sheet (Endo GIA™ Reinforced Reload with Tri-Staple™ Technology). A porcine model was used to examine functional end-to-end anastomosis with and without application of a bioabsorbable polyglycolic acid sheet. As the crotch of the anastomosis is considered the weakest point, a probe was used to test the integrity of these anastomoses. Furthermore, we performed functional end-to-end anastomosis using the Endo GIA™ Reinforced stapler in a clinical series of 20 patients undergoing gastrointestinal tract resection. In all cases, functional end-to-end anastomosis was performed without suture reinforcement. Small intestine anastomoses in the animal study exhibited no weakness at the crotch of the anastomosis, as tested with a probe, suggesting an increased resiliency to conventional complications of functional end-to-end anastomosis. In the clinical population, no postoperative complications were noted. No adhesive intestinal obstruction was noted. Sutureless functional end-to-end anastomosis using the Endo GIA™ Reinforced appears to be safe, efficacious, and straightforward. Reinforcement of the crotch site with a bioabsorbable polyglycolic acid sheet appears to mitigate conventional problems with crotch-site vulnerability.
Willis, Leigh A; Kachur, Rachel; Castellanos, Ted J; Nichols, Kristen; Mendoza, Maria C B; Gaul, Zaneta J; Spikes, Pilgrim; Gamayo, Ashley C; Durham, Marcus D; LaPlace, Lisa; Straw, Julie; Staatz, Colleen; Buge, Hadiza; Hogben, Matthew; Robinson, Susan; Brooks, John; Sutton, Madeline Y
2018-03-01
In the United States, young people (ages 15-24 years) are disproportionately affected by human immunodeficiency virus (HIV) and other sexually transmitted diseases (STDs), due at least in part to inadequate or incorrect HIV/STD-related knowledge, attitudes, beliefs, and behavioral intentions (KABI). Comic book narratives are a proven method of HIV/STD prevention communication to strengthen KABI for HIV/STD prevention. Motion comics, a new type of comic media, are an engaging and low-cost means of narrative storytelling. The objective of this study was to quantitatively evaluate the effectiveness of a pilot six-episode HIV/STD-focused motion comic series to improve HIV/STD-related KABI among young people. We assessed change in HIV/STD knowledge, HIV stigma, condom attitudes, HIV/STD testing attitudes, and behavioral intentions among 138 participants in 15 focus groups immediately before and after viewing the motion comic series. We used paired t-tests and indicators of overall improvement to assess differences between surveys. We found a significant decrease in HIV stigma (p < .001) and increases in both HIV knowledge (p = .002) and behavioral intentions to engage in safe sex (p < .001). In summary, this motion comic intervention improved HIV/STD-related KABI of young adult viewers by reducing HIV stigma and increasing behavioral intentions to engage in safer sex. Our results demonstrate the promise of this novel intervention and support its use to deliver health messages to young people.
Graded Aerobic Treadmill Testing in Adolescent Traumatic Brain Injury Patients.
Cordingley, Dean M; Girardin, Richard; Morissette, Marc P; Reimer, Karen; Leiter, Jeff; Russell, Kelly; Ellis, Michael J
2017-11-01
To examine the safety and tolerability of clinical graded aerobic treadmill testing in recovering adolescent moderate and severe traumatic brain injury (TBI) patients referred to a multidisciplinary pediatric concussion program. We completed a retrospective case series of two moderate and five severe TBI patients (mean age, 17.3 years) who underwent initial Buffalo Concussion Treadmill Testing at a mean time of 71.6 days (range, 55-87) postinjury. Six patients completed one graded aerobic treadmill test each and one patient underwent initial and repeat testing. There were no complications. Five initial treadmill tests were completely tolerated and allowed an accurate assessment of exercise tolerance. Two initial tests were terminated early by the treatment team because of neurological and cardiorespiratory limitations. As a result of testing, two patients were cleared for aerobic exercise as tolerated and four patients were treated with individually tailored submaximal aerobic exercise programs resulting in subjective improvement in residual symptoms and/or exercise tolerance. Repeat treadmill testing in one patient performed after 1 month of treatment with submaximal aerobic exercise prescription was suggestive of improved exercise tolerance. One patient was able to tolerate aerobic exercise following surgery for posterior glottic stenosis. Preliminary results suggest that graded aerobic treadmill testing is a safe, well tolerated, and clinically useful tool to assess exercise tolerance in appropriately selected adolescent patients with TBI. Future prospective studies are needed to evaluate the effect of tailored submaximal aerobic exercise prescription on exercise tolerance and patient outcomes in recovering adolescent moderate and severe TBI patients.
NASA Technical Reports Server (NTRS)
Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.
2010-01-01
Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National
The NASA super pressure balloon - A path to flight
NASA Astrophysics Data System (ADS)
Cathey, H. M.
2009-07-01
The National Aeronautics and Space Administration's Balloon Program Office has invested significant time and effort in extensive ground testing of model super pressure balloons. The testing path has been developed as an outgrowth of the results of the super pressure balloon test flight in 2006. Summary results of the June 2006 super pressure test flight from Kiruna, Sweden are presented including the balloon performance and "lessons learned". This balloons flight performance exceeded expectations, but did not fully deploy. The flight was safely terminated by command. The results of this test flight refocused the project's efforts toward additional ground testing and analysis; a path to flight. A series of small 4 m diameter models were made and tested to further explore the deployment and structural capabilities of the balloons and materials. A series of ˜27 m model balloons were successfully tested indoors. These balloons successfully replicated the cleft seen in the Sweden flight, explored the deployment trade space to help characterize better design approaches, and demonstrated an acceptable fix to the deployment issue. Photogrammetry was employed during these ˜27 m model tests to help characterize both the balloon and gore shape evolution under pressurization. A ˜8.5 m ground model was used to explore the design and materials performance. Results of these tests will be presented. A general overview of some of the other project advancements made related to demonstrating the strain arresting nature of the proposed design, materials and analysis work will also be presented. All of this work has prepared a clear path toward a renewed round of test flights. This paper will give an overview of the development approach pursued for this super pressure balloon development. A description of the balloon design, including the modifications made as a result of the lessons learned, is presented. A short deployment test flight of the National Aeronautics and Space Administration's super pressure balloon took place in June 2008. This flight was from Ft. Sumner, New Mexico. Preliminary results of this flight are presented. Future plans for both ground testing and additional test flights are also presented. Goals of the future test flights, which are staged in increments of increasing suspended load and altitude, are presented. This includes the projected balloon volumes, payload capabilities, test flight locations, and proposed flight schedule.
49 CFR 240.125 - Criteria for testing knowledge.
Code of Federal Regulations, 2010 CFR
2010-10-01
... practices for the safe operation of trains. (c) The testing methods selected by the railroad shall be: (1) Designed to examine a person's knowledge of the railroad's rules and practices for the safe operation of...) Personal safety practices; (ii) Operating practices; (iii) Equipment inspection practices; (iv) Train...
NASA Astrophysics Data System (ADS)
Qiao, Tie; Huang, Wan-Chao; Luo, Xiao-Bing; Zhang, Yang-De
2012-01-01
In recent years, some Chinese doctors have proposed a new concept, gallstone removal without gallbladder excision, along with transition of the medical model. As there is no specialized endoscope for gallstone removal without gallbladder excision, we designed and produced a new series of gallbladder endoscopes and accessories that have already been given a Chinese invention patent (No. ZL200810199041.2). The design of these gallbladder endoscopes was based on the anatomy and physiology of the gallbladder, characteristics of gallbladder disease, ergonomics, and industrial design. This series of gallbladder endoscopes underwent clinical trials in two hospitals appointed by the State Administration of Traditional Chinese Medicine. The clinical trials showed that surgeries of gallstones, gallbladder polyps, and cystic duct calculus could be smoothly performed with these products. In summary, this series of gallbladder endoscopes is safe, reliable, and effective for gallstone removal without gallbladder excision. This note comprehensively introduces the research and design of this series of gallbladder endoscopes.
Wang, Mingxing; Tucker, Jay D; Lu, Peijuan; Wu, Bo; Cloer, Caryn; Lu, Qilong
2012-04-18
Hyperbranched poly(ester amine)s (PEAs) were successfully synthesized by Michael addition reaction between tris[2-(acryloyloxy)ethyl]isocyanurate (TAEI) and low-molecular-weight polyethylenimine (LPEI, M(w) 0.8k, 1.2k, and 2.0k) and evaluated in vitro and in vivo as gene carriers. PEAs effectively condensed plasmid DNA with particle sizes below 200 nm and surface charges between 11.5 and 33.5 mV under tested doses [at the ratios 2-10:1 of polymer/pDNA(w/w)]. The PEAs showed significantly lower cytotoxicities when compared with PEI 25k in two different cell lines. The PEAs (C series) composed of PEI 2k showed higher transgene expression compared to PEAs of PEI 0.8k (A series) or 1.2k (B series). Highest gene transfection efficiency in CHO, C2C12 myoblast, and human skeletal muscle (HSK) cell lines was obtained with TAEI/PEI-2K (C12) at a ratio of 1:2. Both C12, C14(TAEI/PEI-2K at a ratio of 1:4) demonstrated 5-8-fold higher gene expression as compared with PEI 25k in mdx mice in vivo through intramuscular administration. No obvious muscle damage was observed with these new polymers. Higher transfection efficiency and lower toxicity indicate the potential of the biodegradable PEAs as safe and efficient transgene delivery vectors. © 2012 American Chemical Society
Do Leadership Style, Unit Climate, and Safety Climate Contribute to Safe Medication Practices?
Farag, Amany; Tullai-McGuinness, Susan; Anthony, Mary K; Burant, Christopher
2017-01-01
This study aims at: examining if leadership style and unit climate predict safety climate; and testing the direct, indirect, and total effect of leadership style, unit climate, and safety climate on nurses' safe medication practices. The Institute of Medicine and nursing scholars propose that safety climate is a prerequisite to safety practices. However, there is limited empirical evidence about factors contributing to the development of safety climate and about the association with nurses' safe medication practices. This cross-sectional study used survey data from 246 RNs working in a Magnet® hospital. Leadership style and unit climate predicted 20% to 50% of variance on all safety climate dimensions. Model testing revealed the indirect impact of leadership style and unit climate on nurses' safe medication practices. Our hypothesized model explained small amount of the variance on nurses' safe medication practices. This finding suggests that nurses' safe medication practices are influenced by multiple contextual and personal factors that should be further examined.
Planetary Airplane Extraction System Development and Subscale Testing
NASA Technical Reports Server (NTRS)
Teter, John E., Jr.
2006-01-01
The Aerial Regional-scale Environmental Survey (ARES) project employs an airplane as the science platform from which to collect science data in the previously inaccessible, thin atmosphere of Mars. In order for the airplane to arrive safely in the Martian atmosphere a number of sequences must occur. A critical element in the entry sequence at Mars is an extraction maneuver to separate the airplane quickly (in less than a second) from its protective backshell to reduce the possibility of re-contact, potentially leading to mission failure. This paper describes the development, testing, and lessons learned from building a 1/3 scale model of this airplane extraction system. This design, based on the successful Mars Exploration Rover (MER) extraction mechanism, employs a series of trucks rolling along tracks located on the surface of the central parachute can. Numerous tests using high speed video were conducted at the Langley Research Center (LaRC) to validate this concept. One area of concern was that that although the airplane released cleanly, a pitching moment could be introduced. While targeted for a Mars mission, this concept will enable environmental surveys by aircraft in other planetary bodies with a sensible atmosphere such as Venus or Saturn s moon, Titan.
Planetary Airplane Extraction System Development and Subscale Testing
NASA Technical Reports Server (NTRS)
Teter, John E., Jr.
2006-01-01
The Aerial Regional-scale Environmental Survey (ARES) project will employ an airplane as the science platform from which to collect science data in the previously inaccessible, thin atmosphere of Mars. In order for the airplane to arrive safely in the Martian atmosphere, a number of sequences must occur. A critical element in the entry sequence at Mars is an extraction maneuver to separate the airplane quickly (in less than a second) from its protective backshell to reduce the possibility of re-contact, potentially leading to mission failure. This paper describes the development, testing, and lessons learned from building a 1/3 scale model of this airplane extraction system. This design, based on the successful Mars Exploration Rover (MER) extraction mechanism, employs a series of trucks rolling along tracks located on the surface of the central parachute can. Numerous tests using high speed video were conducted at the Langley Research Center to validate this concept. One area of concern was that that although the airplane released cleanly, a pitching moment could be introduced. While targeted for a Mars mission, this concept will enable environmental surveys by aircraft in other planetary bodies with a sensible atmosphere such as Venus or Saturn's moon, Titan.
Fractional Flow Reserve: Does a Cut-off Value add Value?
Mohdnazri, Shah R; Keeble, Thomas R
2016-01-01
Fractional flow reserve (FFR) has been shown to improve outcomes when used to guide percutaneous coronary intervention (PCI). There have been two proposed cut-off points for FFR. The first was derived by comparing FFR against a series of non-invasive tests, with a value of ≤0.75 shown to predict a positive ischaemia test. It was then shown in the DEFER study that a vessel FFR value of ≥0.75 was associated with safe deferral of PCI. During the validation phase, a ‘grey zone’ for FFR values of between 0.76 and 0.80 was demonstrated, where a positive non-invasive test may still occur, but sensitivity and specificity were sub-optimal. Clinical judgement was therefore advised for values in this range. The FAME studies then moved the FFR cut-off point to ≤0.80, with a view to predicting outcomes. The ≤0.80 cut-off point has been adopted into clinical practice guidelines, whereas the lower value of ≤0.75 is no longer widely used. Here, the authors discuss the data underpinning these cut-off values and the practical implications for their use when using FFR guidance in PCI. PMID:29588700
Thermodynamic Properties of Fast Ramped Superconducting Accelerator Magnets for the Fair Project
NASA Astrophysics Data System (ADS)
Fischer, E.; Mierau, A.; Schnizer, P.; Bleile, A.; Gärtner, W.; Guymenuk, O.; Khodzhibagiyan, H.; Schroeder, C.; Sikler, G.; Stafiniak, A.
2010-04-01
The 100 Tm synchrotron SIS 100 is the core component of the international Facility of Antiproton and Ion Research (FAIR) to be built at GSI Darmstadt. The 108 bending magnets are 3 m long 2 T superferric dipoles providing a nominal ramp rate of 4 T/s within a usable aperture of 115 mmṡ60 mm. An intensive R&D period was conducted to minimise the AC losses to lower operation costs and to guarantee a safe thermal stability for long term continuous cycling with a maximum repetition frequency of 1 Hz. The latter requirement is strictly limited by the overall heat flow originated by eddy currents and hysteresis losses in iron yoke and coil as well as by its hydraulic resistance respective to the forced two phase helium cooling flow within the hollow superconducting cable. Recently three full size dipoles—and one quadrupole magnets were built and intensive tests have been started in the end of 2008 at the GSI cryogenic test facility. We present the measured thermodynamic parameters of the first tested dipole: AC losses depending on Bmax and dB/dt for various characteristic ramping modes and conclude for necessary optimisations toward the final design of the series magnets.
Occupational contact dermatitis to a limonene-based solvent in a histopathology technician.
Foti, Caterina; Zambonin, Carlo G; Conserva, Anna; Casulli, Claudia; D'Accolti, Lucia; Angelini, Gianni
2007-02-01
Recently, D-limonene-based solvents are used as a safe alternative to xylene for histological and cytological application to dissolve paraffin. We report the case of a histopathology technician with a recalcitrant hand contact dermatitis strictly related to the use of a limonene-based solvent agent. Patch tests with SIDAPA (Italian Society of Allergological, Professional and Environmental Dermatology) standard series, limonene-based solvent used by the patient and D- and L-limonene (both oxidized and nonoxidized form) and with Giemsa and methylene blue stains were performed. Patch testing gave positive results to oxidized D- and L-limonene. The patient retired from work and promptly improved and healed the hand eczema. Subsequently, the potential occurrence of limonene oxidation products in the incriminated preparation was investigated using gas chromatography-mass spectrometry. While patch test showed positive reaction to oxidized limonene, chemical analysis failed to detect oxidized limonene in the preparations used by the patient. Considering the strict relation between the use of the preparations and the appearance of symptoms, we can assume that oxidized limonene may be produced during the handling of limonene-based products, especially in the presence of oxidants stains, frequently used in histological laboratories.
Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V
2005-01-01
13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The 13C-OABT is accurate non-invasive method for gastric emptying measurement.
ERIC Educational Resources Information Center
Capobianco, Brenda; Thiel, Elizabeth Andrew
2006-01-01
Students may be slathered with SPF 30 sunscreen all summer at the beach or pool, but what do they know about ultraviolet (UV) light radiation and absorption? The authors of this article found the perfect opportunity to help students find out the science behind this important health precaution, when they developed a series of practical strategies…
Reducing Smoking at the Workplace. WBGH Worksite Wellness Series.
ERIC Educational Resources Information Center
Behrens, Ruth A.
Company policies and programs aimed at reducing smoking among employees have a number of other important benefits to employees and the company alike. Limiting or banning smoking helps create a safe and healthy workplace and may reduce direct health care costs, health and life insurance costs, employee absenteeism, costs associated with maintaining…
Acting Out! Combating Homophobia through Teacher Activism. Practitioner Inquiry Series
ERIC Educational Resources Information Center
Blackburn, Mollie V., Ed.; Clark, Caroline T., Ed.; Kenney, Lauren M., Ed.; Smith, Jill M., Ed.
2009-01-01
In this volume, teachers from urban, suburban, and rural districts join together in a teacher inquiry group to challenge homophobia and heterosexism in schools and classrooms. To create safe learning environments for all students they address key topics, including seizing teachable moments, organizing faculty, deciding whether to come out in the…
Entertaining Chemistry--Two Colorful Reactions.
ERIC Educational Resources Information Center
Elsworth, John F.
2000-01-01
Describes two related color-change reactions that are relatively easy and safe to demonstrate. In the "Sunday School Reaction", a black and a white solution are mixed to form a white solution. In the "South Africa Reaction", a series of black, brown, red, and white solutions are mixed to form a clear, colorless solution. (WRM)
Design Lab. USMES "How To" Series.
ERIC Educational Resources Information Center
Donahoe, Charles; And Others
The major emphasis in all Unified Sciences and Mathematics for Elementary Schools (USMES) units is on open-ended, long-range investigations of real problems. Since children often design and build things in USMES, 26 "Design Lab" cards provide information on the safe use and simple maintenance of tools. Each card has a large photograph of…
Creating Safe Learning Zones: The ABC's of Healthy Schools.
ERIC Educational Resources Information Center
2002
This primer was prepared by the Healthy Buildings committee of the Child Proofing Our Communities campaign and is the third in a series of reports. The campaign aims to connect local efforts across the country, raise awareness of toxic threats to children's health, and promote precautionary approaches most protective of children. Following an…
Structural Integrity of an Electron Beam Melted Titanium Alloy.
Lancaster, Robert; Davies, Gareth; Illsley, Henry; Jeffs, Spencer; Baxter, Gavin
2016-06-14
Advanced manufacturing encompasses the wide range of processes that consist of "3D printing" of metallic materials. One such method is Electron Beam Melting (EBM), a modern build technology that offers significant potential for lean manufacture and a capability to produce fully dense near-net shaped components. However, the manufacture of intricate geometries will result in variable thermal cycles and thus a transient microstructure throughout, leading to a highly textured structure. As such, successful implementation of these technologies requires a comprehensive assessment of the relationships of the key process variables, geometries, resultant microstructures and mechanical properties. The nature of this process suggests that it is often difficult to produce representative test specimens necessary to achieve a full mechanical property characterisation. Therefore, the use of small scale test techniques may be exploited, specifically the small punch (SP) test. The SP test offers a capability for sampling miniaturised test specimens from various discrete locations in a thin-walled component, allowing a full characterisation across a complex geometry. This paper provides support in working towards development and validation strategies in order for advanced manufactured components to be safely implemented into future gas turbine applications. This has been achieved by applying the SP test to a series of Ti-6Al-4V variants that have been manufactured through a variety of processing routes including EBM and investigating the structural integrity of each material and how this controls the mechanical response.
26 CFR 1.401(a)(4)-0 - Table of contents.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Composition-of-work-force method. (3) Minimum-benefit method. (4) Grandfather rules for plans in existence on... allocation rates. (3) Safe harbor testing method for cash balance plans. (d) Safe-harbor testing method for...-crediting period. (e) Family aggregation rules. [Reserved] (f) Governmental plans. [Reserved] (g) Corrective...
Fingerprick autologous blood: a novel treatment for dry eye syndrome.
Than, J; Balal, S; Wawrzynski, J; Nesaratnam, N; Saleh, G M; Moore, J; Patel, A; Shah, S; Sharma, B; Kumar, B; Smith, J; Sharma, A
2017-12-01
PurposeDry eye syndrome (DES) causes significant morbidity. Trials of blood-derived products in treatment of the condition show promising results. However, their production is expensive and time-consuming. We investigate fingerprick autologous blood (FAB) as an alternative low-cost, readily accessible treatment for DES.Patients and methodsProspective, non-comparative, interventional case series. In total, 29 eyes of 16 DES patients (2 males and 14 females) from two NHS sites in the United Kingdom. Patients instructed to clean a finger, prick with a blood lancet, and apply a drop of blood to the lower fornix of the affected eye(s), 4 times daily for 8 weeks then stop and review 4 weeks later. Follow-up visits occurred ~3 days, 2, 4, 8 weeks into therapy, and 4 weeks post-cessation. At each visit, visual acuity, corneal staining, Schirmer's test, tear break-up time (TBUT), and ocular comfort index (OCI) were measured, and photographs taken. Results were analysed using Student's paired t-test.ResultsAt 8 weeks, there was improvement in mean Oxford corneal staining grade (3.31 to 2.07 (P<0.0001)), TBUT (5.00 to 7.80 s (P<0.05)), visual acuity (0.08 to 0.01 LogMAR equivalent (P<0.05)), and OCI score (56.03 to 39.72 (P<0.0001)). There was no statistically significant change in Schirmer's test results. Four weeks post-cessation versus immediately after completion of FAB therapy, mean staining grade worsened from 2.07 to 2.86 (P<0.0001). OCI score worsened from 39.72 to 44.67 (P<0.05).ConclusionsIn our limited case series FAB appears to be a safe and effective treatment for DES.
[Surgical experience and results in transperitoneal laparoscopic adrenalectomy].
Hevia Suárez, M; Abascal Junquera, J M; Boix, P; Dieguez, M; Delgado, E; Abascal García, J M; Abascal García, R
2010-05-01
Laparoscopic adrenalectomy is currently the gold standard in surgical management of adrenal pathology. To analyze our results after 12 years of experience in this surgery and to compare with the main published series. we describe retrospectively 100 adrenalectomies performed between 1997-2009. Analyzed variables: age, size, side, preoperative diagnosis, operative time, blood loss, reconversion, hospital stay and histopathologic report. We utilized Fisher test and chi square test to compare categoric data. We utilized t-Student test to compare means from independent groups with normal distribution. We considered statistical significance when p<0.05. Mean age was 53.1 years (+/-14.4). Mean size was 3,7 cm (+/-2.2). In 51% of cases it was the left side. Mean follow-up was 15 months (+/-11.9). Preoperative diagnosis was: functional mass (44%), pheocromocytome (17%), incedentaloma>4 cm (20%), metastasis (10%) and adrenal carcinoma (5%). Mean operative time was 145.1 min (+/-55.6). Mean hematocrite loss was 6.26 points (+/-3.3). Reconversion rate was 9.6%. 2 cases of prolonged postoperative ileus. 2 patients required transfusion. 1 patient death because of an descompensation of liver cirrhosis. 80% of complications were on right side. Mean hospital stay was 6 days (+/-5.6). In last 30 procedures we realized statistical differences with first group, in terms of operative time (119.1 min vs 171.2 min) and hospital stay (4.1 days vs 6.1) (p<0.05). Transperitoneal laparoscopic adrenalectomy is a surgical feasible and safe procedure in urological groups with previous laparoscopic experience. Our results are similar with the published series and confirm the efficacy, security and reproducibility of this technique.
A case series of anophthalmic socket cysts excised utilising fibrin sealant.
Wong, Yun; Clarke, Lucy; Lau, Gordon
2017-10-23
Anophthalmic socket cysts are challenging to remove and incomplete excision has been shown to increase the risk of recurrence. This case series describes a novel technique utilising the fibrin sealant Tisseel (Baxter AG, Vienna, Austria) to retain the socket cyst integrity during surgical removal to facilitate its complete excision. Five patients were included and followed up for a minimum of 1 year, and there were no signs of recurrence in any of the cases. The surgical technique is described and illustrated. This technique is a safe way of simplifying challenging socket cyst surgery.
Boundary Layer Transition Protuberance Tests at NASA JSC Arc-Jet Facility
NASA Technical Reports Server (NTRS)
Larin, M. E.; Marichalar, J. J.; Kinder, G. R.; Campbell, C. H.; Riccio, J. R.; Nquyen, T. Q.; DelPapa, S. V.; Pulsonetti, M. V.
2009-01-01
A series of arc-jet tests in support of the Shuttle Orbiter Boundary Layer Transition flight experiment was conducted in the Channel Nozzle of the NASA Johnson Space Center Atmospheric Reentry Materials and Structures Facility. The boundary layer trip was a protrusion of a certain height and geometry fabricated as part of a 6"x6" tile insert, a special test article made of the Boeing Rigid Insulation tile material and coated with the Reaction Cured Glass used for the bottom fuselage tiles of the Space Shuttle Orbiter. A total of five such tile inserts were manufactured: four with the 0.25-in. trip height, and one with the 0.35-in. trip height. The tile inserts were interchangeably installed in the center of the 24"x24" variable configuration tile array mounted in the 24"x24" test section of the channel nozzle. The objectives of the test series were to demonstrate that the boundary layer trip can safely withstand the Space Shuttle Orbiter flight-like re-entry environments and provide temperature data on the protrusion surface, surfaces of the nearby tiles upstream and downstream of the trip, as well as the bond line between the tiles and the structure. The targeted test environments were defined for the tip of the protrusion, away from the nominal surface of the tile array. The arc jet test conditions were approximated in order to produce the levels of the free stream total enthalpy at the protrusion height similar to those expected in flight. The test articles were instrumented with surface, sidewall and bond line thermocouples. Additionally, Tempilaq temperature-indicating paint was applied to the nominal tiles of the tile array in locations not interfering with the protrusion trip. Five different grades of paint were used that disintegrate at different temperatures between 1500 and 2000 deg F. The intent of using the paint was to gauge the RCG-coated tile surface temperature, as well as determine its usefulness for a flight experiment. This paper provides an overview of the channel nozzle arc jet, test articles and test conditions, as well as the results of the arc-jet tests including the measured temperature response of the test articles, their pre- and post-test surface scans, condition of the thermal paint, and continents on the protrusion tip heating achieved in tests compared to the computational fluid dynamics predictions.
The utility of patch tests using larger screening series of allergens.
Larkin, A; Rietschel, R L
1998-09-01
The number of patch test allergens available within the United States for routine commercial purchase is limited. Allergens chosen for inclusion in routine screening series or patch test trays vary, and the degree of information obtained from any series may or may not serve a patient's needs. Knowledge of how well the allergens chosen for inclusion in the two commercially available sources perform compared with a more expansive panel of tests can help physicians select the more appropriate tests. From 1994 to mid-1997, 554 patients were tested with allergens recommended by the North American Contact Dermatitis Group (NACDG). This included all allergens currently available from both current domestic sources, although not in the identical form used by the Thin-layer Rapid Use Epicutaneous Test (TRUE) test (Glaxo Dermatology, Research Triangle Park, NC). Another 185 patients were tested with supplemental series of allergens. The larger the series of allergens used, the more positive tests were found and the more relevant tests as well. Hermal patch test allergens identified about 55% of the information found by the NACDG series; the TRUE test allergens (but not in the TRUE test system) identified 65%. Of the 103 reactions to supplemental allergens not found by the NACDG series, 59 were relevant. Larger series of allergens can enhance accurate diagnosis of allergic contact dermatitis. No single arbitrary series of allergens can adequately survey the contemporary environment of individual patients. Selection of allergens for testing requires consideration of the patient's history and access to appropriate environmental contactants.
NASA Technical Reports Server (NTRS)
Corliss, L. D.; Talbot, P. D.
1977-01-01
A two-pilot moving base simulator experiment was conducted to assess the effects of servo failures of a flight control system on the transient dynamics of a Bell UH-1H helicopter. The flight control hardware considered was part of the V/STOLAND system built with control authorities of from 20-40%. Servo hardover and oscillatory failures were simulated in each control axis. Measurements were made to determine the adequacy of the failure monitoring system time delay and the servo center and lock time constant, the pilot reaction times, and the altitude and attitude excursions of the helicopter at hover and 60 knots. Safe recoveries were made from all failures under VFR conditions. Pilot reaction times were from 0.5 to 0.75 sec. Reduction of monitor delay times below these values resulted in significantly reduced excursion envelopes. A subsequent flight test was conducted on a UH-1H helicopter with the V/STOLAND system installed. Series servo hardovers were introduced in hover and at 60 knots straight and level. Data from these tests are included for comparison.
Standing-up exerciser based on functional electrical stimulation and body weight relief.
Ferrarin, M; Pavan, E E; Spadone, R; Cardini, R; Frigo, C
2002-05-01
The goal of the present work was to develop and test an innovative system for the training of paraplegic patients when they are standing up. The system consisted of a computer-controlled stimulator, surface electrodes for quadricep muscle stimulation, two knee angle sensors, a digital proportional-integrative-derivative (PID) controller and a mechanical device to support, partially, the body weight (weight reliever (WR)). A biomechanical model of the combined WR and patient was developed to find an optimum reference trajectory for the PID controller. The system was tested on three paraplegic patients and was shown to be reliable and safe. One patient completed a 30-session training period. Initially he was able to stand up only with 62% body weight relief, whereas, after the training period, he performed a series of 30 standing-up/sitting-down cycles with 45% body weight relief. The closed-loop controller was able to keep the patient standing upright with minimum stimulation current, to compensate automatically for muscle fatigue and to smooth the sitting-down movement. The limitations of the controller in connection with a highly non-linear system are considered.
Shared liability? Consultants, pharmacists, and the emergency physician: legal cases and caveats.
Moore, Joshua J; Matlock, Aaron G
2014-05-01
In caring for patients in the Emergency Department (ED), the emergency physician (EP) will often utilize consulting specialists and pharmacists. In the event of an untoward patient outcome, disagreement may arise regarding the liability of each provider. Here, we review a series of malpractice cases involving consulting physicians and pharmacists to illustrate the legal principles of physician-patient relationships and physician duty. Determination of liability in the courts will rest, in part, on whether a physician-patient relationship was formed via an "affirmative act". Consulting physicians may establish a relationship through an overt or implied agreement to participate in a patient's care, or by reviewing specific tests and studies for the purpose of diagnosis and treatment. The courts have defined the duty of the pharmacist to safely dispense medication, and have ascribed the duty to warn of medication side effects to the prescribing physician. Published by Elsevier Inc.
DOT National Transportation Integrated Search
2011-01-14
Through the U.S. Department of Transportations (USDOT) SafeTrip-21 initiative, the USDOT is testing a variety of technologies in a number of locations in California as well as along the I-95 corridor on the east coast. This document presents the e...
A Human Proximity Operations System test case validation approach
NASA Astrophysics Data System (ADS)
Huber, Justin; Straub, Jeremy
A Human Proximity Operations System (HPOS) poses numerous risks in a real world environment. These risks range from mundane tasks such as avoiding walls and fixed obstacles to the critical need to keep people and processes safe in the context of the HPOS's situation-specific decision making. Validating the performance of an HPOS, which must operate in a real-world environment, is an ill posed problem due to the complexity that is introduced by erratic (non-computer) actors. In order to prove the HPOS's usefulness, test cases must be generated to simulate possible actions of these actors, so the HPOS can be shown to be able perform safely in environments where it will be operated. The HPOS must demonstrate its ability to be as safe as a human, across a wide range of foreseeable circumstances. This paper evaluates the use of test cases to validate HPOS performance and utility. It considers an HPOS's safe performance in the context of a common human activity, moving through a crowded corridor, and extrapolates (based on this) to the suitability of using test cases for AI validation in other areas of prospective application.
Gurusamy, Kurinchi Selvan; Best, Lawrence Mj; Tanguay, Cynthia; Lennan, Elaine; Korva, Mika; Bussières, Jean-François
2018-03-27
Occupational exposure to hazardous drugs can decrease fertility and result in miscarriages, stillbirths, and cancers in healthcare staff. Several recommended practices aim to reduce this exposure, including protective clothing, gloves, and biological safety cabinets ('safe handling'). There is significant uncertainty as to whether using closed-system drug-transfer devices (CSTD) in addition to safe handling decreases the contamination and risk of staff exposure to infusional hazardous drugs compared to safe handling alone. To assess the effects of closed-system drug-transfer of infusional hazardous drugs plus safe handling versus safe handling alone for reducing staff exposure to infusional hazardous drugs and risk of staff contamination. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, OSH-UPDATE, CINAHL, Science Citation Index Expanded, economic evaluation databases, the World Health Organization International Clinical Trials Registry Platform, and ClinicalTrials.gov to October 2017. We included comparative studies of any study design (irrespective of language, blinding, or publication status) that compared CSTD plus safe handling versus safe handling alone for infusional hazardous drugs. Two review authors independently identified trials and extracted data. We calculated the risk ratio (RR) and mean difference (MD) with 95% confidence intervals (CI) using both fixed-effect and random-effects models. We assessed risk of bias according to the risk of bias in non-randomised studies of interventions (ROBINS-I) tool, used an intracluster correlation coefficient of 0.10, and we assessed the quality of the evidence using GRADE. We included 23 observational cluster studies (358 hospitals) in this review. We did not find any randomised controlled trials or formal economic evaluations. In 21 studies, the people who used the intervention (CSTD plus safe handling) and control (safe handling alone) were pharmacists or pharmacy technicians; in the other two studies, the people who used the intervention and control were nurses, pharmacists, or pharmacy technicians. The CSTD used in the studies were PhaSeal (13 studies), Tevadaptor (1 study), SpikeSwan (1 study), PhaSeal and Tevadaptor (1 study), varied (5 studies), and not stated (2 studies). The studies' descriptions of the control groups were varied. Twenty-one studies provide data on one or more outcomes for this systematic review. All the studies are at serious risk of bias. The quality of evidence is very low for all the outcomes.There is no evidence of differences in the proportion of people with positive urine tests for exposure between the CSTD and control groups for cyclophosphamide alone (RR 0.83, 95% CI 0.46 to 1.52; I² = 12%; 2 studies; 2 hospitals; 20 participants; CSTD: 76.1% versus control: 91.7%); cyclophosphamide or ifosfamide (RR 0.09, 95% CI 0.00 to 2.79; 1 study; 1 hospital; 14 participants; CSTD: 6.4% versus control: 71.4%); and cyclophosphamide, ifosfamide, or gemcitabine (RR not estimable; 1 study; 1 hospital; 36 participants; 0% in both groups).There is no evidence of a difference in the proportion of surface samples contaminated in the pharmacy areas or patient-care areas for any of the drugs except 5-fluorouracil, which was lower in the CSTD group than in the control (RR 0.65, 95% CI 0.43 to 0.97; 3 studies, 106 hospitals, 1008 samples; CSTD: 9% versus control: 13.9%).The amount of cyclophosphamide was lower in pharmacy areas in the CSTD group than in the control group (MD -49.34 pg/cm², 95% CI -84.11 to -14.56, I² = 0%, 7 studies; 282 hospitals, 1793 surface samples). Additionally, one interrupted time-series study (3 hospitals; 342 samples) demonstrated a change in the slope between pre-CSTD and CSTD (3.9439 pg/cm², 95% CI 1.2303 to 6.6576; P = 0.010), but not between CSTD and post-CSTD withdrawal (-1.9331 pg/cm², 95% CI -5.1260 to 1.2598; P = 0.20). There is no evidence of difference in the amount of the other drugs between CSTD and control groups in the pharmacy areas or patient-care areas.None of the studies report on atmospheric contamination, blood tests, or other measures of exposure to infusional hazardous drugs such as urine mutagenicity, chromosomal aberrations, sister chromatid exchanges, or micronuclei induction.None of the studies report short-term health benefits such as reduction in skin rashes, medium-term reproductive health benefits such as fertility and parity, or long-term health benefits related to the development of any type of cancer or adverse events.Five studies (six hospitals) report the potential cost savings through the use of CSTD. The studies used different methods of calculating the costs, and the results were not reported in a format that could be pooled via meta-analysis. There is significant variability between the studies in terms of whether CSTD resulted in cost savings (the point estimates of the average potential cost savings ranged from (2017) USD -642,656 to (2017) USD 221,818). There is currently no evidence to support or refute the routine use of closed-system drug transfer devices in addition to safe handling of infusional hazardous drugs, as there is no evidence of differences in exposure or financial benefits between CSTD plus safe handling versus safe handling alone (very low-quality evidence). None of the studies report health benefits.Well-designed multicentre randomised controlled trials may be feasible depending upon the proportion of people with exposure. The next best study design is interrupted time-series. This design is likely to provide a better estimate than uncontrolled before-after studies or cross-sectional studies. Future studies may involve other alternate ways of reducing exposure in addition to safe handling as one intervention group in a multi-arm parallel design or factorial design trial. Future studies should have designs that decrease the risk of bias and enable measurement of direct health benefits in addition to exposure. Studies using exposure should be tested for a relevant selection of hazardous drugs used in the hospital to provide an estimate of the exposure and health benefits of using CSTD. Steps should be undertaken to ensure that there are no other differences between CSTD and control groups, so that one can obtain a reasonable estimate of the health benefits of using CSTD.
Ground Handling of Batteries at Test and Launch-site Facilities
NASA Technical Reports Server (NTRS)
Jeevarajan, Judith A.; Hohl, Alan R.
2008-01-01
Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.
Clinical Inquiry: Is megestrol acetate safe and effective for malnourished nursing home residents?
Wen, Frances K; Millar, James; Oberst-Walsh, Linda; Nashelsky, Joan
2018-02-01
No. Megestrol acetate (MA) is neither safe nor effective for stimulating appetite in malnourished nursing home residents. It increases the risk of deep vein thrombosis (strength of recommendation [SOR]: C, 2 retrospective chart reviews), but isn't associated with other new or worsening events or disorders (SOR: B, single randomized controlled trial [RCT]). Over a 25-week period, MA wasn't associated with increased mortality (SOR: B, single RCT). After 44 months, however, MA-treated patients showed decreased median survival (SOR: B, single case-control study). Consistent, meaningful weight gain was not observed with MA treatment (SOR: B, single case-control study, single RCT, 2 retrospective chart reviews, single prospective case-series).
The Iron Dog: The Care and Keeping of a Sno-go.
ERIC Educational Resources Information Center
Keller, Rosanne
Part of a series of home literacy readers with conversational text and sketches, this booklet addresses the Alaskan environment, where the snowmobile or sno-go has recently replaced the dogsled and mechanized land travel. Only with safe drivers is this "Iron Dog" one of man's best friends. The good sno-go driver stays off roads, plane…
Product Safety: "An Ounce of Prevention". Health and the Consumer.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Div. of Elementary and Secondary Education.
Secondary level students learn about product safety in this consumer education learning activity package, which is one of a series. While the majority of products are safe, there remains a small percentage of consumer goods which reach the market place containing a real or potential hazard to the consumer's safety. This module is designed to make…
Saturating time-delay transformer for overcurrent protection. [Patent application
Praeg, W.F.
1975-12-18
Electrical loads connected to dc supplies are protected from damage by overcurrent in the case of a load fault by connecting in series with the load a saturating transformer that detects a load fault and limits the fault current to a safe level for a period long enough to correct the fault or else disconnect the power supply.
Oceanography for Divers: Waves, Tides, and Currents. Diver Education Series.
ERIC Educational Resources Information Center
Somers, Lee H.
To dive safely, it is suggested that the diver have a working knowledge of waves, tides, currents, and water quality. Lack of understanding and respect for ocean currents and surf can be of serious consequence to the diver. This paper on the diving environment is designed to provide the diver with a general understanding of the physical…
Part Two: Surgery--Can This Be a Cure for Epilepsy?
ERIC Educational Resources Information Center
McGoldrick, Patricia E.
2010-01-01
In the first installment of this series (Exceptional Parent Magazine, May 2010), the author discussed epilepsy surgery performed in persons whose areas of brain abnormality were initially deemed to be too extensive to safely perform a resection of the involved area. The process leading to surgical remediation for seizures is an involved one, but…
Quality Teaching: Building a Flexible and Dynamic Approach. GEC Working Paper Series. Number 2
ERIC Educational Resources Information Center
Leu, Elizabeth; Hays, Frances; LeCzel, Donna Kay; O'Grady, Barbara
2005-01-01
Good basic education depends on several factors working in harmony. The first is that students be healthy, safe, and ready to learn. Other essentials include an enabling policy environment and transparent management; a curriculum that reflects the society's values and aspirations for learning; and community support for education and parents'…
Basic Principles--Outdoor Living Skills Series. Instructor Manual.
ERIC Educational Resources Information Center
Deaton, Don
The priorities for sustaining life--air, shelter, water, and food--are the subjects of this module designed to give junior and senior high school students the foundation for safe, rewarding experiences in the outdoors. Five 50-minute lesson plans cover the basic need in order of priority: air (3 minutes to survive without it), shelter (3 hours, in…
Saturating time-delay transformer for overcurrent protection
Praeg, Walter F.
1977-01-01
Electrical loads connected to d-c supplies are protected from damage by overcurrent in the case of a load fault by connecting in series with the load a saturating transformer that detects a load fault and limits the fault current to a safe level for a period long enough to correct the fault or else disconnect the power supply.
76 FR 15872 - Airworthiness Directives; Airbus Model A330-200 and -300 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-22
... applicable to the Safe Life Airworthiness Limitation Items (SL ALI) are given in Airbus A330 ALS Part 1 and A340 ALS Part 1, which are approved by the European Aviation Safety Agency (EASA). The revision 05 of Airbus A340 ALS Part 1 introduces more restrictive maintenance requirements and/or airworthiness...
Child Welfare Outcomes 2002-2005. Report to Congress
ERIC Educational Resources Information Center
US Department of Health and Human Services, 2008
2008-01-01
"Child Welfare Outcomes 2002-2005: Report to Congress" (Child Welfare Outcomes Report) is the seventh in a series of annual reports from the U.S. Department of Health and Human Services (the Department). The reports are developed in accordance with section 479A of the Social Security Act (as amended by the Adoption and Safe Families Act…
Fire Safe Together. Kindergarten. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the kindergarten component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of kindergarten students, its objectives include developing basic awareness of fire and burn dangers, developing simple actions to reduce injury, and encouraging parent involvement. Texas essential…
ERIC Educational Resources Information Center
Maxey, Phyllis F.; And Others
One of a series of units on business designed for secondary school students, this packet examines the issues concerning business responsibility for safe products. Teacher and student materials are provided in separate sections. The teacher's guide presents an overview of activities and objectives, five detailed lesson plans, answer keys,…
State of Outrage: Immigrant-Related Legislation and Education in Arizona
ERIC Educational Resources Information Center
Powers, Jeanne M.; Williams, Tiffany R.
2012-01-01
In April 2010, Arizona made national headlines when Governor Jan Brewer signed SB 1070, the "Support Our Law Enforcement and Safe Neighborhoods Act" which was aimed at deterring illegal immigration to Arizona. SB 1070 is the most prominent of a series of laws and other state policies targeting immigrants in Arizona that date back to the…
Living Lightly: Energy Conservation in Housing.
ERIC Educational Resources Information Center
Bender, Tom
This publication contains a series of papers which promote the concepts of energy conservation and offer safe and convenient ways of handling all aspects of our lives affected by energy without having to depend in any way on fossil fuels or nuclear power. These changes, which can be brought about in homes and in energy flows affected by the…
How Safe Are Kid-Safe Search Engines?
ERIC Educational Resources Information Center
Masterson-Krum, Hope
2001-01-01
Examines search tools available to elementary and secondary school students, both human-compiled and crawler-based, to help direct them to age-appropriate Web sites; analyzes the procedures of search engines labeled family-friendly or kid safe that use filters; and tests the effectiveness of these services to students in school libraries. (LRW)
ERIC Educational Resources Information Center
Ramsay, Peter
2017-01-01
In this article, I test the claims of the UK government and universities that the Prevent programme aims to create a safe space for the discussion of "extremist" ideas in universities. I do this by comparing the main elements of the Prevent duty that has been imposed on universities with those of safe spaces as imagined by student…
SYBR safeTM efficiently replaces ethidium bromide in Aspergillus fumigatus gene disruption.
Canela, H M S; Takami, L A; Ferreira, M E S
2017-02-08
Invasive aspergillosis is a disease responsible for high mortality rates, caused mainly by Aspergillus fumigatus. The available drugs are limited and this disease continues to occur at an unacceptable frequency. Gene disruption is essential in the search for new drug targets. An efficient protocol for A. fumigatus gene disruption was described but it requires ethidium bromide, a genotoxic agent, for DNA staining. Therefore, the present study tested SYBR safe TM , a non-genotoxic DNA stain, in A. fumigatus gene disruption protocol. The chosen gene was cipC, which has already been disrupted successfully in our laboratory. A deletion cassette was constructed in Saccharomyces cerevisiae and used in A. fumigatus transformation. There was no statistical difference between the tested DNA stains. The success rate of S. cerevisiae transformation was 63.3% for ethidium bromide and 70% for SYBR safe TM . For A. fumigatus gene disruption, the success rate for ethidium bromide was 100 and 97% for SYBR safe TM . In conclusion, SYBR safe TM efficiently replaced ethidium bromide, making this dye a safe and efficient alternative for DNA staining in A. fumigatus gene disruption.
Edgar, Dale; Zorzi, Lisa M; Wand, Ben M; Brockman, Nathalie; Griggs, Carolyn; Clifford, Matthew; Wood, Fiona
2011-06-01
Acute burn patients suffer pain and secondary hyperalgesia. This alters movement patterns and impairs function. Non-pharmacological methods of treatment are limited and lack rigorous testing and evidence for use. The treatment in this case series was designed to direct conscious attention to, and normalise sensation of, the injured limb in pain free way. The aim of the study was to describe a cortical training programme (CTP) in acute upper limb burn patients and to investigate the efficacy, safety and feasibility of the protocol. The study is a descriptive case series (n=6). Study tasks engaged sensory and motor nerves to influence the perception of the injured area. Visual and tactile inputs to maintain and, or normalise the homuncular map were central to the intervention. One patient, who commenced the study without resting pain, responded negatively. The remaining five patients had reduced pain and fear avoidance behaviours with associated improvement in arm function. The CTP approach is safe and feasible for use with acute burn patients where pain is reported at rest. Comparative studies are required to determine the relative efficacy of the program to usual interventions and the patients who may benefit from the technique. Copyright © 2011 Elsevier Ltd and ISBI. All rights reserved.
Berggren, Elisabet; White, Andrew; Ouedraogo, Gladys; Paini, Alicia; Richarz, Andrea-Nicole; Bois, Frederic Y; Exner, Thomas; Leite, Sofia; Grunsven, Leo A van; Worth, Andrew; Mahony, Catherine
2017-11-01
We describe and illustrate a workflow for chemical safety assessment that completely avoids animal testing. The workflow, which was developed within the SEURAT-1 initiative, is designed to be applicable to cosmetic ingredients as well as to other types of chemicals, e.g. active ingredients in plant protection products, biocides or pharmaceuticals. The aim of this work was to develop a workflow to assess chemical safety without relying on any animal testing, but instead constructing a hypothesis based on existing data, in silico modelling, biokinetic considerations and then by targeted non-animal testing. For illustrative purposes, we consider a hypothetical new ingredient x as a new component in a body lotion formulation. The workflow is divided into tiers in which points of departure are established through in vitro testing and in silico prediction, as the basis for estimating a safe external dose in a repeated use scenario. The workflow includes a series of possible exit (decision) points, with increasing levels of confidence, based on the sequential application of the Threshold of Toxicological (TTC) approach, read-across, followed by an "ab initio" assessment, in which chemical safety is determined entirely by new in vitro testing and in vitro to in vivo extrapolation by means of mathematical modelling. We believe that this workflow could be applied as a tool to inform targeted and toxicologically relevant in vitro testing, where necessary, and to gain confidence in safety decision making without the need for animal testing.
NASA Technical Reports Server (NTRS)
Trawny, Nikolas; Huertas, Andres; Luna, Michael E.; Villalpando, Carlos Y.; Martin, Keith E.; Carson, John M.; Johnson, Andrew E.; Restrepo, Carolina; Roback, Vincent E.
2015-01-01
The Hazard Detection System (HDS) is a component of the ALHAT (Autonomous Landing and Hazard Avoidance Technology) sensor suite, which together provide a lander Guidance, Navigation and Control (GN&C) system with the relevant measurements necessary to enable safe precision landing under any lighting conditions. The HDS consists of a stand-alone compute element (CE), an Inertial Measurement Unit (IMU), and a gimbaled flash LIDAR sensor that are used, in real-time, to generate a Digital Elevation Map (DEM) of the landing terrain, detect candidate safe landing sites for the vehicle through Hazard Detection (HD), and generate hazard-relative navigation (HRN) measurements used for safe precision landing. Following an extensive ground and helicopter test campaign, ALHAT was integrated onto the Morpheus rocket-powered terrestrial test vehicle in March 2014. Morpheus and ALHAT then performed five successful free flights at the simulated lunar hazard field constructed at the Shuttle Landing Facility (SLF) at Kennedy Space Center, for the first time testing the full system on a lunar-like approach geometry in a relevant dynamic environment. During these flights, the HDS successfully generated DEMs, correctly identified safe landing sites and provided HRN measurements to the vehicle, marking the first autonomous landing of a NASA rocket-powered vehicle in hazardous terrain. This paper provides a brief overview of the HDS architecture and describes its in-flight performance.
DOT National Transportation Integrated Search
2010-11-10
Through the U.S. Department of Transportations (USDOT) SafeTrip-21 initiative, the USDOT is testing a variety of technologies in a number of locations in California as well as along the I-95 corridor on the east coast. This document presents the e...
DOT National Transportation Integrated Search
2010-12-10
Through the U.S. Department of Transportations (USDOT) SafeTrip-21 initiative, the USDOT is testing a variety of technologies in a number of locations in California as well as along the I-95 corridor on the east coast. This document presents the e...
DOT National Transportation Integrated Search
2011-12-30
The purpose of this document is to present the findings of the national evaluation of the I-95 Corridor Coalitions Airport Ground Transport Travel Information project, one element of the I-95 Test Bed conducted under the USDOTs SafeTrip-21 Init...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2009-05-01
The Department of Energy's Oak Ridge National Laboratory (ORNL) conducts cutting edge scientific research. ORNL utilizes removable electronic media, such as computer hard drives, compact disks, data tapes, etc., to store vast amounts of classified information. Incidents involving breakdowns in controls over classified removable electronic media have been a continuous challenge for the Department. The loss of even one piece of such media can have serious national security implications. In 2004, the Department had a complex-wide 'stand-down' of all activities using classified removable electronic media, and such media containing Secret/Restricted Data or higher classified data was designated 'Accountable Classified Removablemore » Electronic Media' (ACREM). As part of the stand-down, sites were required to conduct a 100 percent physical inventory of all ACREM; enter it all into accountability; and conduct security procedure reviews and training. Further, the Department implemented a series of controls, including conducting periodic inventories, utilizing tamper proof devices on ACREM safes, and appointing trained custodians to be responsible for the material. After performance testing and validation that the required accountability systems were in place, ACREM operations at ORNL were approved for restart on August 10, 2004. We conducted a review at ORNL and associated facilities to determine whether ACREM is managed, protected, and controlled consistent with applicable requirements. We found that: (1) Eight pieces of Secret/Restricted Data media had not been identified as ACREM and placed into a system of accountability. Consequently, the items were not subject to all required protections and controls, such as periodic accountability inventories, oversight by a trained custodian, or storage in a designated ACREM safe. (However, the items were secured in safes approved for classified material.) (2) Other required ACREM protections and controls were not implemented as follows: a tamper indicating device was not being used on an ACREM safe; records documenting when a certain safe was opened did not support that a purported inventory had been conducted; and a safe inventory had not been completed in a timely manner. (3) A Personal Digital Assistant and a thumb drive, both capable of recording or transmitting data, were stored in a security area without an analysis to identify vulnerabilities and compensatory measures having been conducted, as required. We also found that an ORNL Cooperative Research and Development Agreement partner had not disabled classified computer ports at the partner's site that were capable of writing classified information to external or removable media, as required. We made several recommendations designed to enhance the security of ACREM, security areas, and computers.« less
Effectiveness of a Driving Intervention on Safe Community Mobility for Returning Combat Veterans
2017-05-01
study is a follow-on to prior DOD funded work “Efficacy of a Driving Intervention Program on Safe Community Mobility for Combat Veterans”. Funding for...lack of control groups, suggest that a simu- lator-based OT-DI can provide a safe environment for testing and training of CV to reduce dangerous...AWARD NUMBER: W81XWH-15-1-0032 TITLE: Effectiveness of a Driving Intervention on Safe Community Mobility for Returning Combat Veterans
2017-01-01
time histories with peak pressures of approximately 250 psi and 500 psi. 1.2 TESTING OBJECTIVES The first goal of this test series was to explore how...finally the late- time at-rest fragments were physically collected and analyzed post-test. Because this test series physically collected over 50,000...for a single fragmenting object. Comparing the three measurement techniques used in this test series , the late- time physically- collected mass
ERIC Educational Resources Information Center
Congress of the U.S., Washington, DC. Senate Committee on Environment and Public Works.
This report was written to accompany the Radon Testing for Safe Schools Act (S.1697), a bill that provides for radon testing of schools located in high risk radon areas and provides limited financial assistance to schools for mitigation of high levels of radon. A description of radon, its harmful effects, and the radon levels detected in schools…
Safe Affordable Fission Engine-(SAFE-) 100a Heat Exchanger Thermal and Structural Analysis
NASA Technical Reports Server (NTRS)
Steeve, B. E.
2005-01-01
A potential fission power system for in-space missions is a heat pipe-cooled reactor coupled to a Brayton cycle. In this system, a heat exchanger (HX) transfers the heat of the reactor core to the Brayton gas. The Safe Affordable Fission Engine- (SAFE-) 100a is a test program designed to thermally and hydraulically simulate a 95 Btu/s prototypic heat pipe-cooled reactor using electrical resistance heaters on the ground. This Technical Memorandum documents the thermal and structural assessment of the HX used in the SAFE-100a program.
NASA Astrophysics Data System (ADS)
Schoess, Jeffrey N.; Seifert, Greg; Paul, Clare A.
1996-05-01
The smart aircraft fastener evaluation (SAFE) system is an advanced structural health monitoring effort to detect and characterize corrosion in hidden and inaccessible locations of aircraft structures. Hidden corrosion is the number one logistics problem for the U.S. Air Force, with an estimated maintenance cost of $700M per year in 1990 dollars. The SAFE system incorporates a solid-state electrochemical microsensor and smart sensor electronics in the body of a Hi-Lok aircraft fastener to process and autonomously report corrosion status to aircraft maintenance personnel. The long-term payoff for using SAFE technology will be in predictive maintenance for aging aircraft and rotorcraft systems, fugitive emissions applications such as control valves, chemical pipeline vessels, and industrial boilers. Predictive maintenance capability, service, and repair will replace the current practice of scheduled maintenance to substantially reduce operational costs. A summary of the SAFE concept, laboratory test results, and future field test plans is presented.
Water Under Fire: A Seven Part Video Series on Canada's Water
NASA Astrophysics Data System (ADS)
Mrazek, R.; Byrne, J.; Rabe, N.; Gallant, G.
2003-12-01
Canada's water is under escalating pressure from a host of threats. Increasingly, our water is being tainted, misused and over allocated. Experts have identified a multitude of threats to water quantity and quality. Among them, climate change impacts on water supply, and the effects of pesticides, pathogens, industrial waste, urban runoff, and rising demands. These and other threats are the roots to a serious shortage of high quality, safe water sources. In the 1990s, waterborne diseases have re-emerged as one of the primary health issues on a national and global scale. This seven-part video series brings science voices together and provides a nationwide context. The first six programs in the series explore regional concerns: Rocky Mountains, Prairie Waters, Northern Waters, Great Lakes Basin, St. Lawrence and Atlantic Canada. The final program covers the national and international perspectives.
Pediatric Digital Necrosis Secondary to Dressing Application: A Case Series.
Bjorklund, Kim A; Rice, Dahlia M; Amalfi, Ashley N
2018-04-01
Pediatric digital necrosis resulting in revision amputation is a devastating outcome following digital dressing application. We report a series of 4 pediatric patients (age: 21 months-11 years) who presented for surgical consultation related to digital ischemia and irreversible necrosis following the application of Coban digital dressings. A review of the literature demonstrated that such injuries had not previously been described. In our case series, Coban dressing was utilized as a deterrent for thumb sucking, fingertip tuft fractures with nail bed lacerations, and a phalanx fracture secondary to crush injury. All 4 children suffered digital necrosis secondary to Coban dressings and ultimately required revision amputation. We discuss risks factors, application practices, and strategies to minimize complications with digital dressings in the pediatric population with the intent of creating awareness among hand surgeons to help promote safe practices and improve patient outcomes.
NASA Astrophysics Data System (ADS)
Menne, Matthew J.; Williams, Claude N., Jr.
2005-10-01
An evaluation of three hypothesis test statistics that are commonly used in the detection of undocumented changepoints is described. The goal of the evaluation was to determine whether the use of multiple tests could improve undocumented, artificial changepoint detection skill in climate series. The use of successive hypothesis testing is compared to optimal approaches, both of which are designed for situations in which multiple undocumented changepoints may be present. In addition, the importance of the form of the composite climate reference series is evaluated, particularly with regard to the impact of undocumented changepoints in the various component series that are used to calculate the composite.In a comparison of single test changepoint detection skill, the composite reference series formulation is shown to be less important than the choice of the hypothesis test statistic, provided that the composite is calculated from the serially complete and homogeneous component series. However, each of the evaluated composite series is not equally susceptible to the presence of changepoints in its components, which may be erroneously attributed to the target series. Moreover, a reference formulation that is based on the averaging of the first-difference component series is susceptible to random walks when the composition of the component series changes through time (e.g., values are missing), and its use is, therefore, not recommended. When more than one test is required to reject the null hypothesis of no changepoint, the number of detected changepoints is reduced proportionately less than the number of false alarms in a wide variety of Monte Carlo simulations. Consequently, a consensus of hypothesis tests appears to improve undocumented changepoint detection skill, especially when reference series homogeneity is violated. A consensus of successive hypothesis tests using a semihierarchic splitting algorithm also compares favorably to optimal solutions, even when changepoints are not hierarchic.
Preventing Falls and Fall-Related Injuries at Home.
Powell-Cope, Gail; Thomason, Susan; Bulat, Tatjana; Pippins, Karla M; Young, Heather M
2018-01-01
: This article is part of a series, Supporting Family Caregivers: No Longer Home Alone, published in collaboration with the AARP Public Policy Institute. Results of focus groups, conducted as part of the AARP Public Policy Institute's No Longer Home Alone video project, supported evidence that family caregivers aren't given the information they need to manage the complex care regimens of family members. This series of articles and accompanying videos aims to help nurses provide caregivers with the tools they need to manage their family member's health care at home.The articles in this new installment of the series explain principles for promoting safe mobility that nurses should reinforce with family caregivers. Each article also includes an informational tear sheet-Information for Family Caregivers-that contains links to instructional videos. To use this series, nurses should read the article first, so they understand how best to help family caregivers, and then encourage the caregivers to watch the videos and ask questions. For additional information, see Resources for Nurses.
Jeffery, A.; Elmquist, R. E.; Cage, M. E.
1995-01-01
Precision tests verify the dc equivalent circuit used by Ricketts and Kemeny to describe a quantum Hall effect device in terms of electrical circuit elements. The tests employ the use of cryogenic current comparators and the double-series and triple-series connection techniques of Delahaye. Verification of the dc equivalent circuit in double-series and triple-series connections is a necessary step in developing the ac quantum Hall effect as an intrinsic standard of resistance. PMID:29151768
Injuries of the spine sustained whilst surfboard riding.
Dimmick, Simon; Brazier, Daivd; Wilson, Peter; Anderson, Suzanne E
2013-01-01
Surfboard riding is a popular sport worldwide. Although surfing is considered a 'safe' pastime, significant injuries do occur, particularly to the head and cervical spine. Spinal injuries most commonly occur when the surfer's head strikes the seafloor. This case series identifies the spectrum of spinal pathologies sustained whilst surfing and their imaging appearances. No similar study has previously been published.
76 FR 8612 - Airworthiness Directives; Airbus Model A340-200, -300, -500, and -600 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... Section (ALS) Part 1 ``Safe Life Airworthiness Limitation Items (SL ALI)'' for different source route... Airbus A330 and A340 ALS Part 1 introduces more restrictive maintenance requirements and/or airworthiness limitations as specified in Airbus A330 and A340 ALS Part 1 revision 04. The unsafe condition is failure of...
76 FR 42024 - Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-18
... limitations are currently included in Airbus A318/A319/A320/A321 Airworthiness Limitations Section (ALS). The... Safety Agency (EASA) and referenced in Airbus Airworthiness Limitations Section (ALS) Part 2. The issue...: Revise Airworthiness Limitations Section (ALS) To Incorporate Safe Life ALIs (g) For Model A318-111 and...
76 FR 16582 - Airworthiness Directives; Airbus Model A318, A319, A320, and A321 Series Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-24
... to revise the Airworthiness Limitations Section (ALS) of the Instructions for Continued Airworthiness... Airbus A318/A319/ A320/A321 ALS Part 1--Safe Life Airworthiness Limitation Items, dated February 28, 2006... included in Airbus A318/A319/A320/A321 Airworthiness Limitations Section (ALS). The airworthiness...
ERIC Educational Resources Information Center
Ni Raghallaigh, M.; Cunniffe, R.
2013-01-01
This article explores the experiences of students who participated in a series of seminars that employed active learning methodologies. The study on which the article is based involved two parts. First, students completed a questionnaire after each seminar, resulting in 468 questionnaires. Second, nine students participated in a focus group where…
ERIC Educational Resources Information Center
National School Boards Association, Alexandria, VA.
This publication, resulting from a survey of more than 2,000 school districts, focuses on school violence and ways to prevent it. Section 1 discusses both the problem of school violence and also the critical role that school boards must play in keeping schools safe. This section also includes information about how school boards can develop…
Resolving Conflict through Peer Mediation. A Series of Solutions and Strategies. Number 9.
ERIC Educational Resources Information Center
Rogers, Marie
Research confirms the fact that violence is a growing problem in American society. The frequency of reports of youth involved in violent acts reflects an inability to handle conflicts in safe, constructive ways among this age group. Although the business of schools is to educate, many students are more concerned with their own safety than…
The Potomac River is the largest tributary of the Chesapeake Bay and has been a key study site in water quality research, beginning with work to address public health concerns such as safe drinking water and waterborne disease during periods of population growth and urbanization ...
Sacral neuromodulation and cardiac pacemakers.
Roth, Ted M
2010-08-01
Potential for cross-talk between cardiac pacemakers and sacral neuromodulation remains speculative. We present a case series of patients with cardiac pacemakers who underwent staged Interstim (Medtronic, Minneapolis, MN) implantation and patients who had pulse generator implantation who later required cardiac pacemakers. No cross-talk was demonstrated in either group. Sacral neuromodulation appears to be safe in the setting of cardiac pacemakers without cardioversion/defibrillation technology.
Electronic switches and control circuits: A compilation
NASA Technical Reports Server (NTRS)
1971-01-01
The innovations in this updated series of compilations dealing with electronic technology represents a carefully selected collection of items on electronic switches and control circuits. Most of the items are based on well-known circuit design concepts that have been simplified or refined to meet NASA's demanding requirement for reliability, simplicity, fail-safe characteristics, and the capability of withstanding environmental extremes.
Production Line Materials. Youth Training Scheme. Core Exemplar Work Based Project.
ERIC Educational Resources Information Center
Further Education Staff Coll., Blagdon (England).
This trainer's guide is intended to assist supervisors of work-based career training projects in helping students understand the operation of an assembly line, including safe working procedures. The guide is one in a series of core curriculum modules that is intended for use in combination on- and off-the-job programs to familiarize youth with the…
29 CFR 1915.15 - Maintenance of safe conditions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Enclosed Spaces and Other Dangerous Atmospheres in Shipyard Employment § 1915.15 Maintenance of safe... within a tested confined or enclosed space or other dangerous atmosphere occurs, work in the affected...
29 CFR 1915.15 - Maintenance of safe conditions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Enclosed Spaces and Other Dangerous Atmospheres in Shipyard Employment § 1915.15 Maintenance of safe... within a tested confined or enclosed space or other dangerous atmosphere occurs, work in the affected...
29 CFR 1915.15 - Maintenance of safe conditions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Enclosed Spaces and Other Dangerous Atmospheres in Shipyard Employment § 1915.15 Maintenance of safe... within a tested confined or enclosed space or other dangerous atmosphere occurs, work in the affected...
Karim, Abdul Basit; Lindsey, Sean; Bovino, Brian; Berenstein, Alejandro
2016-02-01
This case series describes patients with head and neck arteriovenous malformations who underwent oral and maxillofacial surgical procedures combined with interventional radiology techniques to minimize blood loss. Twelve patients underwent femoral cerebral angiography to visualize the extent of vascular malformation. Before the surgical procedures, surgical sites were devascularized by direct injection of hemostatic or embolic agents. Direct puncture sclerotherapy at the base of surgical sites was performed using Surgiflo or n-butylcyanoacrylate glue. Surgical procedures were carried out in routine fashion. A hemostatic packing of FloSeal, Gelfoam, and Avitene was adapted to the surgical sites. Direct puncture sclerotherapy with Surgiflo or n-butylcyanoacrylate glue resulted in minimal blood loss intraoperatively. Local application of the FloSeal, Gelfoam, and Avitene packing sustained hemostasis and produced excellent healing postoperatively. Patients with arteriovenous malformations can safely undergo routine oral and maxillofacial surgical procedures with minimal blood loss when appropriate endovascular techniques and local hemostatic measures are used by the interventional radiologist and oral and maxillofacial surgeon. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Madi, Banyana Cecilia; Hussein, Julia; Hounton, Sennen; D'Ambruoso, Lucia; Achadi, Endang; Arhinful, Daniel Kojo
2007-09-01
A participatory approach to priority setting in programme evaluation may help improve the allocation and more efficient use of scarce resources especially in low-income countries. Research agendas that are the result of collaboration between researchers, programme managers, policy makers and other stakeholders have the potential to ensure rigorous studies are conducted on matters of local priority, based on local, expert knowledge. This paper describes a process involving key stakeholders to elicit and prioritise evaluation needs for safe motherhood in three developing countries. A series of reiterative consultations with safe motherhood stakeholders from each country was conducted over a period of 36 months. In each country, the consultation process consisted of a series of participatory workshops; firstly, stakeholder's views on evaluation were elicited with parallel descriptive work on the contexts. Secondly, priorities for evaluation were identified from stakeholders; thirdly, the evaluation-priorities were refined; and finally, the evaluation research questions, reflecting the identified priorities, were agreed and finalised. Three evaluation-questions were identified in each country, and one selected, on which a full scale evaluation was undertaken. While there is a great deal written about the importance of transparent and participatory priority setting in evaluation; few examples of how such processes could be implemented exist, particularly for maternal health programmes. Our experience demonstrates that the investment in a participatory priority-setting effort is high but the process undertaken resulted in both globally and contextually-relevant priorities for evaluation. This experience provides useful lessons for public health practitioners committed to bridging the research-policy interface.
Structural Integrity of an Electron Beam Melted Titanium Alloy
Lancaster, Robert; Davies, Gareth; Illsley, Henry; Jeffs, Spencer; Baxter, Gavin
2016-01-01
Advanced manufacturing encompasses the wide range of processes that consist of “3D printing” of metallic materials. One such method is Electron Beam Melting (EBM), a modern build technology that offers significant potential for lean manufacture and a capability to produce fully dense near-net shaped components. However, the manufacture of intricate geometries will result in variable thermal cycles and thus a transient microstructure throughout, leading to a highly textured structure. As such, successful implementation of these technologies requires a comprehensive assessment of the relationships of the key process variables, geometries, resultant microstructures and mechanical properties. The nature of this process suggests that it is often difficult to produce representative test specimens necessary to achieve a full mechanical property characterisation. Therefore, the use of small scale test techniques may be exploited, specifically the small punch (SP) test. The SP test offers a capability for sampling miniaturised test specimens from various discrete locations in a thin-walled component, allowing a full characterisation across a complex geometry. This paper provides support in working towards development and validation strategies in order for advanced manufactured components to be safely implemented into future gas turbine applications. This has been achieved by applying the SP test to a series of Ti-6Al-4V variants that have been manufactured through a variety of processing routes including EBM and investigating the structural integrity of each material and how this controls the mechanical response. PMID:28773590
NASA Technical Reports Server (NTRS)
Hooke, F. H.
1972-01-01
Both the conventional and reliability analyses for determining safe fatigue life are predicted on a population having a specified (usually log normal) distribution of life to collapse under a fatigue test load. Under a random service load spectrum, random occurrences of load larger than the fatigue test load may confront and cause collapse of structures which are weakened, though not yet to the fatigue test load. These collapses are included in reliability but excluded in conventional analysis. The theory of risk determination by each method is given, and several reasonably typical examples have been worked out, in which it transpires that if one excludes collapse through exceedance of the uncracked strength, the reliability and conventional analyses gave virtually identical probabilities of failure or survival.
29 CFR 1919.29 - Limitations on safe working loads and proof loads.
Code of Federal Regulations, 2013 CFR
2013-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof... pertinent limitations based on stability and/or on structural competence at particular radii. Safe working...
29 CFR 1919.29 - Limitations on safe working loads and proof loads.
Code of Federal Regulations, 2012 CFR
2012-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof... pertinent limitations based on stability and/or on structural competence at particular radii. Safe working...
29 CFR 1919.29 - Limitations on safe working loads and proof loads.
Code of Federal Regulations, 2011 CFR
2011-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof... pertinent limitations based on stability and/or on structural competence at particular radii. Safe working...
29 CFR 1919.29 - Limitations on safe working loads and proof loads.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof... pertinent limitations based on stability and/or on structural competence at particular radii. Safe working...
29 CFR 1919.29 - Limitations on safe working loads and proof loads.
Code of Federal Regulations, 2014 CFR
2014-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) GEAR CERTIFICATION Certification of Vessels: Tests and Proof... pertinent limitations based on stability and/or on structural competence at particular radii. Safe working...
ERIC Educational Resources Information Center
Cornish, Greg; Wines, Robin
The Number Test of the ACER Mathematics Profile Series, contains 30 items, for each of three suggested grade levels: 7-8, 8-9, and 9-10. Raw scores on all tests in the ACER Mathematics Profile Series (Number, Operations, Space and Measurement) are converted to a common scale called MAPS, a major feature of the Series. Based on the Rasch Model,…
Cho, Sumi; Lee, Eunjoo
2017-12-01
Recently, the patient's role in preventing adverse events has been emphasized. Patients who are more knowledgeable about safety issues are more likely to engage in safety initiatives. Therefore, nurses need to develop techniques and tools that increase patients' knowledge in preventing adverse events. For this reason, an educational smartphone application for patient safety called "Safe Patients" was developed through an iterative process involving a literature review, expert consultations, and pilot testing of the application. To determine the effect of "Safe Patients," it was implemented for patients in surgical units in a tertiary hospital in South Korea. The change in patients' knowledge about patient safety was measured using seven true/false questions developed in this study. A one-group pretest and posttest design was used, and a total of 123 of 190 possible participants were tested. The percentage of correct answers significantly increased from 64.5% to 75.8% (P < .001) after implementation of the "Safe Patients" application. This study demonstrated that the application "Safe Patients" could effectively improve patients' knowledge of safety issues. This will ultimately empower patients to engage in safe practices and prevent adverse events related to surgery.
Absence of subchronic oral toxicity and genotoxicity of rice koji with Aspergillus terreus.
Yun, Jun-Won; Kim, Seung-Hyun; Kim, Yun-Soon; You, Ji-Ran; Cho, Eun-Young; Yoon, Jung-Hee; Kwon, Euna; Lee, Sang Ju; Kim, Seong Pil; Seo, Jae Hoon; In, Jae Pyung; Ahn, Jae Hun; Jang, Ja-June; Park, Jin-Sung; Che, Jeong-Hwan; Kang, Byeong-Cheol
2017-10-01
Koji products have been considered as an effective fermented food consumed in East Asia with many health benefits. Particularly, rice koji with Aspergillus terreus (RAT) has been reported to be able to prevent hyperlipidemia and hepatic steatosis through regulating cholesterol synthesis. Despite its biological activities, there is a lack of comprehensive information to give an assurance of its safety. Therefore, the objective of this study was to perform a series of toxicological studies (repeated dose oral toxicity and genotoxicity) according to test guidelines published by the Organization for Economic Cooperation and Development. Along with acute toxicity study using rats and beagle dogs, a 13-week toxicity study revealed no clear RAT-related toxic changes, including body weight, mortality, hematology, serum biochemistry, organ weight, and histopathology after oral administration at doses of 500, 1000, and 2000 mg/kg BW. The no-observed-adverse-effect level of RAT was considered to be more than 2000 mg/kg BW/day in rats of both genders. In addition, potential genotoxicity was evaluated using a standard battery of tests (Ames test, chromosome aberration assay, and micronucleus assay) which revealed that RAT showed no genotoxicity. Accordingly, these results suggest that RAT is a safe and non-toxic functional food for human consumption at proper dose. Copyright © 2017. Published by Elsevier Inc.
Parkinson's disease and driving ability
Singh, Rajiv; Pentland, Brian; Hunter, John; Provan, Frances
2007-01-01
Objectives To explore the driving problems associated with Parkinson's disease (PD) and to ascertain whether any clinical features or tests predict driver safety. Methods The driving ability of 154 individuals with PD referred to a driving assessment centre was determined by a combination of clinical tests, reaction times on a test rig and an in‐car driving test. Results The majority of cases (104, 66%) were able to continue driving although 46 individuals required an automatic transmission and 10 others needed car modifications. Ability to drive was predicted by the severity of physical disease, age, presence of other associated medical conditions, particularly dementia, duration of disease, brake reaction, time on a test rig and score on a driving test (all p<0.001). The level of drug treatment and the length of driving history were not correlated. Discriminant analysis revealed that the most important features in distinguishing safety to drive were severe physical disease (Hoehn and Yahr stage 3), reaction time, moderate disease associated with another medical condition and high score on car testing. Conclusions Most individuals with PD are safe to drive, although many benefit from car modifications or from using an automatic transmission. A combination of clinical tests and in‐car driving assessment will establish safety to drive, and a number of clinical correlates can be shown to predict the likely outcome and may assist in the decision process. This is the largest series of consecutive patients seen at a driving assessment centre reported to date, and the first to devise a scoring system for on‐road driving assessment. PMID:17178820
Tan, John F; Masani, Kei; Vette, Albert H; Zariffa, José; Robinson, Mark; Lynch, Cheryl; Popovic, Milos R
2014-01-01
The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FES system for standing. The Inverted Pendulum Standing Apparatus (IPSA) is a mechanical inverted pendulum, whose angular position is determined by the subject's ankle joint angle as controlled by the FES system while having the subject's body fixed in a standing frame. This approach provides a setup that is safe, prevents falling, and enables a research and design team to rigorously test various closed-loop controlled FES systems applied to the ankle joints. To demonstrate the feasibility of using the IPSA, we conducted a case series that employed the device for studying FES closed-loop controllers for regulating ankle joint kinematics during standing. The utilized FES system stimulated, in able-bodied volunteers, the plantarflexors as they prevent toppling during standing. Four different conditions were compared, and we were able to show unique performance of each condition using the IPSA. We concluded that the IPSA is a useful tool for developing and testing closed-loop controlled FES systems for regulating ankle joint position during standing.
Tan, John F.; Masani, Kei; Vette, Albert H.; Zariffa, José; Robinson, Mark; Lynch, Cheryl; Popovic, Milos R.
2014-01-01
The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FES system for standing. The Inverted Pendulum Standing Apparatus (IPSA) is a mechanical inverted pendulum, whose angular position is determined by the subject's ankle joint angle as controlled by the FES system while having the subject's body fixed in a standing frame. This approach provides a setup that is safe, prevents falling, and enables a research and design team to rigorously test various closed-loop controlled FES systems applied to the ankle joints. To demonstrate the feasibility of using the IPSA, we conducted a case series that employed the device for studying FES closed-loop controllers for regulating ankle joint kinematics during standing. The utilized FES system stimulated, in able-bodied volunteers, the plantarflexors as they prevent toppling during standing. Four different conditions were compared, and we were able to show unique performance of each condition using the IPSA. We concluded that the IPSA is a useful tool for developing and testing closed-loop controlled FES systems for regulating ankle joint position during standing. PMID:27350992
Poster - Thur Eve - 10: Long term stability of VMAT quality assurance parameters using an EPID.
Pekar, J; Diamond, K R
2012-07-01
The rapidly growing use of volumetric modulated arc therapy (VMAT) treatments in radiation therapy calls for a quantitative, automated, and reliable quality assurance (QA) procedure that can be used routinely in the clinical setting. In this work, we present a series VMAT QA procedures used to assess dynamic multi-leaf collimator (MLC) positional accuracy, variable dose-rate accuracy, and MLC leaf speed accuracy. The QA procedures were performed using amorphous silicon electronic portal imaging devices (EPID) to determine the long term stability of the measured parameters on two Varian linear accelerators. The measurements were repeated weekly on both linear accelerators for a period of three months and the EPID images were analyzed using custom Matlab software. The results of the picket fence tests indicate that MLC leaf positions can be identified to within 0.11 mm and 0.15 mm for static gantry delivery and VMAT delivery respectively. In addition, the dose-rate, gantry speed and MLC leaf speed tests both show very good stability over the measurement period. The measurements thus far, suggest that a number of the dosimetry tests may be suitable for quarterly QA for Varian iX and Trilogy linacs. However, additional measurements are required to confirm the frequency with which each test is required for safe and reliable VMAT delivery at our centre. © 2012 American Association of Physicists in Medicine.
Hałasa, Maciej; Maciejewska, Dominika; Baśkiewicz-Hałasa, Magdalena; Machaliński, Bogusław; Safranow, Krzysztof; Stachowska, Ewa
2017-04-08
Increased intestinal permeability has been implicated in various pathologies, has various causes, and can develop during vigorous athletic training. Colostrum bovinum is a natural supplement with a wide range of supposed positive health effects, including reduction of intestine permeability. We assessed influence of colostrum supplementation on intestinal permeability related parameters in a group of 16 athletes during peak training for competition. This double-blind placebo-controlled study compared supplementation for 20 days with 500 mg of colostrum bovinum or placebo (whey). Gut permeability status was assayed by differential absorption of lactulose and mannitol (L/M test) and stool zonulin concentration. Baseline L/M tests found that six of the participants (75%) in the colostrum group had increased intestinal permeability. After supplementation, the test values were within the normal range and were significantly lower than at baseline. The colostrum group Δ values produced by comparing the post-intervention and baseline results were also significantly lower than the placebo group Δ values. The differences in stool zonulin concentration were smaller than those in the L/M test, but were significant when the Δ values due to intervention were compared between the colostrum group and the placebo group. Colostrum bovinum supplementation was safe and effective in decreasing of intestinal permeability in this series of athletes at increased risk of its elevation.
Morishita, Yuki; Nomura, Yusuke; Fukui, Chie; Fujisawa, Ayano; Watanabe, Kayo; Fujimaki, Hideo; Kumada, Hidefumi; Inoue, Kaoru; Morikawa, Tomomi; Takahashi, Miwa; Kawakami, Tsuyoshi; Sakoda, Hideyuki; Mukai, Tomokazu; Yuba, Toshiyasu; Inamura, Ken-Ichi; Tanoue, Akito; Miyazaki, Ken-Ichi; Chung, Ung-Il; Ogawa, Kumiko; Yoshida, Midori; Haishima, Yuji
2018-04-01
Di (2-ethylhexyl) phthalate (DEHP), a typical plasticizer used for polyvinyl chloride (PVC), is eluted from PVC-made blood containers and protects against red blood cell (RBC) hemolysis. However, concerns have arisen regarding the reproductive and developmental risks of DEHP in humans, and the use of alternative plasticizers for medical devices has been recommended worldwide. In this study, we propose that the use of a novel plasticizer, 4-cyclohexene-1,2-dicarboxylic acid dinonyl ester (DL9TH), could help produce more useful and safe blood containers. PVC sheet containing DL9TH and di (2-ethylhexyl) 4-cyclohexene-1,2-dicarboxylate (DOTH) provides comparable or superior protective effects to RBCs relative to PVC sheet containing DEHP or di-isononyl-cyclohexane-1,2-dicarboxylate (DINCH ® , an alternative plasticizer that has been used in PVC sheets for blood containers). The total amount of plasticizer eluted from DOTH/DL9TH-PVC sheets is nearly the same as that eluted from DEHP-PVC sheets. In addition, DOTH/DL9TH-PVC has better cold resistance than DEHP- and DINCH ® -PVC sheets. In vitro and in vivo tests for biological safety based on International Organization for Standardization guidelines (10993 series) suggest that the DOTH/DL9TH-PVC sheet can be used safely. Subchronic toxicity testing of DL9TH in male rats in accordance with the principles of Organisation for Economic Co-operation and Development Test Guideline 408 showed that DL9TH did not induce adverse effects up to the highest dose level tested (717 mg/kg body weight/day). There were no effects on testicular histopathology and sperm counts, and no indications of endocrine effects: testosterone, thyroid-stimulating hormone, follicle-stimulating hormone, and 17β-estradiol were unchanged by the treatment, compared with the control group. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1052-1063, 2018. © 2017 Wiley Periodicals, Inc.
Is a specific eyelid patch test series useful? Results of a French prospective study.
Assier, Haudrey; Tetart, Florence; Avenel-Audran, Martine; Barbaud, Annick; Ferrier-le Bouëdec, Marie-Christine; Giordano-Labadie, Françoise; Milpied, Brigitte; Amsler, Emmanuelle; Collet, Evelyne; Girardin, Pascal; Soria, Angèle; Waton, Julie; Truchetet, François; Bourrain, Jean-Luc; Gener, Gwendeline; Bernier, Claire; Raison-Peyron, Nadia
2018-06-08
Eyelids are frequent sites of contact dermatitis. No prospective study focused on eyelid allergic contact dermatitis (EACD) has yet been published, and this topic has never been studied in French patients. To prospectively evaluate the usefulness of an eyelid series in French patients patch tested because of EACD, and to describe these patients. We prospectively analysed standardized data for all patients referred to our departments between September 2014 and August 2016 for patch testing for suspected EACD as the main reason. All patients were patch tested with an eyelid series, the European baseline series (EBS), the French additional series, and their personal products. Patch testing with additional series and repeated open application tests (ROATs) or open tests were performed if necessary. A standardized assessment of the relevance was used, and the analysis of the results was focused on patients having positive test results with a current certain relevance. Two-hundred and sixty-four patients (238 women and 26 men) were included. Three-hundred and twenty-two tests gave positive results in 167 patients, 84 of whom had currently relevant reactions: 56 had currently relevant positive test reactions to the EBS, 16 had currently relevant positive test reactions to their personal products, 8 had currently relevant positive test reactions to the French additional series, and 4 had currently relevant positive test reactions to the eyelid series. Sixty-seven per cent of all relevant cases were related to cosmetic products. The most frequent allergens with current relevance were methylisothiazolinone (10.2%), fragrance mix I (3%), nickel (2.7%), hydroxyperoxides of linalool (2.7%) and limonene (2.3%), and Myroxylon pereirae (2.3%). Current atopic dermatitis was found in 9.5% of patients. The duration of dermatitis was shorter (23.2 vs 34.2 months; P = .035) in patients with currently relevant test reactions. The percentage of currently relevant tests remained the same when atopic patients or dermatitis localized only on the eyelids were taken into account. In French patients, testing for EACD with the extended baseline series and personal products, also including ROATs and use tests, appears to be adequate, considering the currently relevant positive test reactions. The regular addition of an eyelid series does not seem to be necessary. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
The assessment of fitness to drive in people with dementia.
Lincoln, Nadina B; Radford, Kate A; Lee, Elizabeth; Reay, Alice C
2006-11-01
To determine whether cognitive tests predict fitness to drive in patients with dementia. Two group comparison of patients with dementia and healthy elderly volunteers, and comparison of patients with dementia who were found safe to drive and those found unsafe, followed by a validation study. Forty-two people with dementia and 33 healthy elderly volunteers with no known memory problems who were driving. Of the 42 people with dementia 37 were assessed on the road. A second sample of 17 people with dementia was also assessed on the road. Stroke Drivers Screening Assessment, Mini Mental State Examination, Salford Objective Recognition Test, Stroop Test, Test of Everyday Attention, Visual Object and Space Perception Battery, Behavioural Assessment of the Dysexecutive Syndrome, Adult Memory and Information Processing Battery. All healthy elderly volunteers were safe to drive but 10 of the 27 patients with dementia were unsafe. Discriminant function analysis identified a combination of tests, which correctly classified 92% of drivers with dementia as safe or unsafe. Validation of this prediction on an independent sample had 59% accuracy using a cut-off of 0 but 88% accuracy using a cut-off of 5. Safety to drive in people with dementia could be predicted from a combination of six cognitive tests. These correctly identified 67% of safe drivers in a validation sample. This assessment could be used to identify those who need evaluation of their safety on the road. Copyright (c) 2006 John Wiley & Sons, Ltd.
Sachs, B; Al Masaoudi, T; Merk, H F; Erdmann, S
2004-10-01
Amino-penicillins are a major cause of delayed-type reactions to penicillins. The aim of this study was to establish a diagnostic approach for the characterization of the individual penicillin-specific polyclonal lymphocyte reactivity in order to detect side chain-specific sensitization to amino-penicillins. Patients can then be advised to undergo a tolerance test with safe penicillins instead of provocation with culprit penicillins for confirmation of penicillin allergy. We investigated penicillin-specific polyclonal lymphocyte reactivity in nine patients with delayed-type reactions to amino-penicillins by a combined in vivo (patch, prick and intracutaneous tests with delayed readings) and in vitro (lymphocyte transformation test, LTT) approach. A combination of LTT and skin tests improved the sensitivity for the characterization of penicillin-specific polyclonal lymphocyte reactivity and allowed the detection of three different patterns of lymphocyte reactivity. Four patients showed a side chain-specific sensitization to amino-penicillins in vivo and in vitro and were advised to undergo tolerance tests with safe penicillins. Two patients agreed and were exposed to parenteral benzyl-penicillin and oral phenoxymethyl-penicillin which they tolerated without complications. These data suggest that a combined in vivo and in vitro approach is helpful for the detection of side chain-specific sensitization to amino-penicillins. Patients with such sensitization are very likely to tolerate safe penicillins, thereby expanding their therapeutic options when antibiotic treatment is required.
Residential Tornado Safe Rooms from Commodity Wood Products: Wall Development and Impact Testing
Robert H. Falk; James J. Bridwell; John C. Hermanson
2015-01-01
In the United States, tornadoes cause significant damage and result in many injuries and deaths. Although the development and use of tornado safe rooms and shelters have helped reduce the human toll associated with these events, the cost of these structures is often too high for many that could benefit from their use. The development of a residential tornado safe room...
Romano, C; Carosso, A; Bosio, D; Chiesa, A; Gullino, A; Turrini, A
2003-01-01
Aim of the study was to verify the reliability in clinical practice of patch testing with "standard" series and additional series of haptens for the diagnosis of occupational and non-occupational allergic contact dermatitis, evaluating positive reactions and relating those reactions to professional categories. A total of 392 out of 937 patients (41.8%) showed at least one positive reaction to "standard" series testing; the hapten most frequently noted as the cause of positive reaction was nickel sulphate. Professional categories that showed positive reactions to "standard" series most frequently were clerks, hairdressers and hospital auxiliary workers. Among 897 patients tested with nonstandard allergens, only 124 (13.8%) elicited at least one positive reaction, ammonium persulphate being the most frequently positive hapten. A dominant percentage of positive results was seen in hairdressers and cleaning personnel. No positive reactions were observed in a large number of haptens, tested more than 200 times. Haptens of "standard series" elicited a higher number of positive reaction than the additional series, even though there was a high specificity of few additional series haptens in some professional categories. Data suggest some caution in systematically testing additional series, despite a higher accuracy and diagnostic efficacy in some job categories.
Series and parallel arc-fault circuit interrupter tests.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jay Dean; Fresquez, Armando J.; Gudgel, Bob
2013-07-01
While the 2011 National Electrical Codeª (NEC) only requires series arc-fault protection, some arc-fault circuit interrupter (AFCI) manufacturers are designing products to detect and mitigate both series and parallel arc-faults. Sandia National Laboratories (SNL) has extensively investigated the electrical differences of series and parallel arc-faults and has offered possible classification and mitigation solutions. As part of this effort, Sandia National Laboratories has collaborated with MidNite Solar to create and test a 24-string combiner box with an AFCI which detects, differentiates, and de-energizes series and parallel arc-faults. In the case of the MidNite AFCI prototype, series arc-faults are mitigated by openingmore » the PV strings, whereas parallel arc-faults are mitigated by shorting the array. A range of different experimental series and parallel arc-fault tests with the MidNite combiner box were performed at the Distributed Energy Technologies Laboratory (DETL) at SNL in Albuquerque, NM. In all the tests, the prototype de-energized the arc-faults in the time period required by the arc-fault circuit interrupt testing standard, UL 1699B. The experimental tests confirm series and parallel arc-faults can be successfully mitigated with a combiner box-integrated solution.« less
NASA Technical Reports Server (NTRS)
Holden, D. G.
1975-01-01
Hard Over Monitoring Equipment (HOME) has been designed to complement and enhance the flight safety of a flight research helicopter. HOME is an independent, highly reliable, and fail-safe special purpose computer that monitors the flight control commands issued by the flight control computer of the helicopter. In particular, HOME detects the issuance of a hazardous hard-over command for any of the four flight control axes and transfers the control of the helicopter to the flight safety pilot. The design of HOME incorporates certain reliability and fail-safe enhancement design features, such as triple modular redundancy, majority logic voting, fail-safe dual circuits, independent status monitors, in-flight self-test, and a built-in preflight exerciser. The HOME design and operation is described with special emphasis on the reliability and fail-safe aspects of the design.
Opportunities for Policy Leadership on Afterschool Care. Policy Briefing Series. Issue 5
ERIC Educational Resources Information Center
Kang, Andrew; Weber, Julie
2010-01-01
For most full-time employed parents, the gap between the end of the school day and the time they arrive home from work adds up to about 20 to 25 hours per week. Thus, many parents look to afterschool programs to satisfy their desire for safe, enriching experiences for their children while they are working. "Afterschool" is the general term used to…
ERIC Educational Resources Information Center
Advance CTE: State Leaders Connecting Learning to Work, 2016
2016-01-01
This report, the second installment in Advance CTE's "Connecting the Classroom to Careers," series, explores an issue that is often a stumbling block for K-12 work-based learning--ensuring these experiences are safe and legal for students. This report features New Jersey, Kentucky and California and their approaches to dismantling…
ERIC Educational Resources Information Center
Shaw, C. Frank, III; Webb, James W.; Rothenberger, Otis
2016-01-01
The nature of acidic and basic (alkaline) oxides can be easily illustrated via a series of three straightforward classroom demonstrations for high school and general chemistry courses. Properties of carbon dioxide, sulfur dioxide, and magnesium oxide are revealed inexpensively and safely. Additionally, the very different kinetics of hydration of…
ERIC Educational Resources Information Center
Kellogg Foundation, Battle Creek, MI.
This is the third in a series of reports summarizing the investment of the W. K. Kellogg Foundation in community-based health programming. It addresses the health issues confronting young people in U.S. society by profiling eight different community-based approaches to adolescent health. The programs described, all sponsored by the Kellogg…
ERIC Educational Resources Information Center
O'Brien, Catherine
Tilonia, a typical rural village of the State of Rajasthan (India), is home to the Social Work and Research Centre (SWRC). Since 1972, SWRC has brought educational services, safe drinking water, health care, and employment to villages in the area. It has started 150 night schools in 89 villages, where children who work during the day develop…
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the second grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of second grade students, its objectives include acquiring basic understanding of how to prevent and put out fires and developing greater self-direction to prevent and react to fire, smoke, or burn…
Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.
Tudor, G R; Rodgers, P M; West, K P
1999-08-01
Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.
Simple Automatic File Exchange (SAFE) to Support Low-Cost Spacecraft Operation via the Internet
NASA Technical Reports Server (NTRS)
Baker, Paul; Repaci, Max; Sames, David
1998-01-01
Various issues associated with Simple Automatic File Exchange (SAFE) are presented in viewgraph form. Specific topics include: 1) Packet telemetry, Internet IP networks and cost reduction; 2) Basic functions and technical features of SAFE; 3) Project goals, including low-cost satellite transmission to data centers to be distributed via an Internet; 4) Operations with a replicated file protocol; 5) File exchange operation; 6) Ground stations as gateways; 7) Lessons learned from demonstrations and tests with SAFE; and 8) Feedback and future initiatives.
[Laparoscopic management of ureteroileal stenosis: Long term follow up.
Emiliani, Esteban; Gavrilov, Pavel; Mayordomo, Olga; Salvador, Josep; Palou, Joan; Rosales, Antonio; Villavicencio, Humberto
2017-05-01
To describe the laparoscopic approach for uretero-ileal anastomosis strictures and to analyse our long term series. A retrospective review was performed evaluating our series of patients with benign ureteroileal anastomosis strictures treated laparoscopically from 2011 to 2017. Demographics and perioperative data were obtained and analyzed. Complications were described with the Clavien-Dindo classification. The surgical technique was described and a literature review was performed. Eleven procedures were performed in ten patients. Mean blood loss was 180 ml. All the operations were performed laparoscopically without conversion. Mean hospital stay was 10 days (4-23). Early complications were Clavien-Dindo I y II: Two cases of limited anastomosis leakage, one lymphorrea, one paralitic ileum and one accidental descent of the ureteral catheter. Mean follow-up was 56 months (12-179) No late complications have been described. Based on our series with 5 year follow up, the laparoscopic approach for uretero-ileal anastomosis strictures is feasible and safe.
Targeted Delivery of Drugs to Brain Tumors (LBNL Summer Lecture Series)
Forte, Trudy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Life Sciences Division; ChildrenâÂÂs Hospital Oakland Research Inst. (CHORI), Oakland, CA (United States)
2017-12-15
Summer Lecture Series 2007: Trudy Forte of Berkeley Lab's Life Sciences Division will discuss her work developing nano-sized low-density lipoprotein (LDL) particles that can be used as a safe and effective means of delivering anticancer drugs to brain tumors, particularly glioblastoma multiforme. This is the most common malignant brain tumor in adults and one of the deadliest forms of cancer. Her research team found that the synthetic LDL particles can target and kill such tumors cells in vitro. The nanoparticles are composed of a lipid core surrounded by a peptide. The peptide contains an amino acid sequence that recognizes the LDL receptor, and the lipid core has the ability to accumulate anti-cancer drugs.
Noncovich, Alain; Priest, Chad; Ung, Jane; Patron, Andrew P; Servant, Guy; Brust, Paul; Servant, Nicole; Faber, Nathan; Liu, Hanghui; Gonsalves, Nicole S; Ditschun, Tanya L
2017-08-15
The paper presents the activity trends for a novel series of phenoxyacetyl amides as human TRPM8 receptor agonists. This series encompasses in vitro activity values ranging from the micromolar to the picomolar levels. Sensory evaluation of these molecules highlights their relevance as cooling agents for oral applications. The positive outcome of the complete evaluation of N-(1H-pyrazol-3-yl)-N-(thiophen-2-ylmethyl)-2-(p-tolyloxy)acetamide resulted in its approval for Generally Recognized As Safe (GRAS) status by the Flavor & Extract Manufacturer Association (FEMA) as FEMA 4809. Copyright © 2017 Elsevier Ltd. All rights reserved.
Prediction Analysis for Measles Epidemics
NASA Astrophysics Data System (ADS)
Sumi, Ayako; Ohtomo, Norio; Tanaka, Yukio; Sawamura, Sadashi; Olsen, Lars Folke; Kobayashi, Nobumichi
2003-12-01
A newly devised procedure of prediction analysis, which is a linearized version of the nonlinear least squares method combined with the maximum entropy spectral analysis method, was proposed. This method was applied to time series data of measles case notification in several communities in the UK, USA and Denmark. The dominant spectral lines observed in each power spectral density (PSD) can be safely assigned as fundamental periods. The optimum least squares fitting (LSF) curve calculated using these fundamental periods can essentially reproduce the underlying variation of the measles data. An extension of the LSF curve can be used to predict measles case notification quantitatively. Some discussions including a predictability of chaotic time series are presented.
An approach to natalizumab hypersensitivity: a case series of induction of tolerance.
Camacho-Halili, Marie; George, Roxanne; Gottesman, Malcolm; Davis-Lorton, Mark
2011-02-01
Induction of tolerance protocols have been applied successfully to manage allergic reactions to many medications. Hypersensitivity reactions to natalizumab (TYSABRI®) have been recognized as a growing problem. In circumstances where a hypersensitivity reaction to a medication has occurred, but no suitable alternative exists, drug induction of tolerance protocols may be considered. Drug induction of tolerance protocols were performed in three patients with prior hypersensitivity reactions to natalizumab. All three patients tolerated the protocol without adverse reactions, allowing for the safe reintroduction of natalizumab. To conclude, this case series demonstrates success with an induction of tolerance procedure to a highly effective biological agent for multiple sclerosis, in patients with allergic reactions to natalizumab.
UAS in the NAS Flight Test Series 3 Overview
NASA Technical Reports Server (NTRS)
Murphy, James R.
2015-01-01
The UAS Integration in the NAS Project is conducting a series of flight tests to acheive the following objectives: 1.) Validate results previously collected during project simulations with live data 2.) Evaluate TCAS IISS interoperability 3.) Test fully integrated system in a relevant live test environment 4.) Inform final DAA and C2 MOPS 5.) Reduce risk for Flight Test Series 4.
Epoxy-based production of wind turbine rotor blades: occupational contact allergies.
Pontén, Ann; Carstensen, Ole; Rasmussen, Kurt; Gruvberger, Birgitta; Isaksson, Marléne; Bruze, Magnus
2004-03-01
An industry producing rotor blades for wind turbines with an epoxy-based technology had experienced an increasing number of workers with dermatitis, among whom the frequency of occupational contact allergy (OCA) was suspected to be underestimated. To investigate the frequency of OCA by patch-testing with a specially profiled occupational patch test series. In a blinded study design, 603 workers were first interviewed and thereafter clinically examined. Based on a history of work-related skin disease, clinical findings of dermatitis, or both, 325 (53.9%) of the workers were patch-tested with an occupational patch test series and the European Standard patch test series. Of the 603 investigated workers, 10.9% had OCA and 5.6% had contact allergy to epoxy resin in the standard test series. Contact allergy to amine hardeners/catalysts was found in 4.1% of the workers. Among the workers with OCA, 48.5% reacted to work material other than epoxy resin in the European Standard patch test series. Approximately 50% of the workers with OCA would not have been detected if only the European Standard patch test series had been used.
NASA Technical Reports Server (NTRS)
Sauerwein, Timothy A.; Gostomski, Thomas
2008-01-01
The ST5 technology demonstration mission led by GSFC of NASA's New Millennium Program managed by JPL consisted of three micro satellites (approximately 30 kg each) deployed into orbit from the Pegasus XL launch vehicle. In order to meet the launch date schedule of ST5, a different approach was required rather than the standard I&T approach used for single, room-sized satellites. The three spacecraft were designed, integrated, and tested at NASA Goddard Space Flight Center. It was determined that there was insufficient time in the schedule to perform three spacecraft I&T activities in series using standard approaches. The solution was for spacecraft #1 to undergo integration and test first, followed by spacecraft #2 and #3 simultaneously. This simultaneous integration was successful for several reasons. Each spacecraft had a Lead Test Conductor who planned and coordinated their spacecraft through its integration and test activities. One team of engineers and technicians executed the integration of all three spacecraft, learning and gaining knowledge and efficiency as spacecraft #1 integration and testing progressed. They became acutely familiar with the hardware, operation and processes for I&T, thus had the experience and knowledge to safely execute I&T for spacecraft #2 and #3. The integration team was extremely versatile; each member could perform many different activities or work any spacecraft, when needed. ST5 was successfully integrated, tested and shipped to the launch site per the I&T schedule that was planned three years previously. The I&T campaign was completed with ST5's successful launch on March 22, 2006.
Lien, Yu-Hsin; Huang, Hui-Pi
2008-12-15
To evaluate the effectiveness of ketoconazole as a treatment for dogs with pituitary-dependent hyperadrenocorticism (PDH). Retrospective case series. 48 client-owned dogs in which PDH was diagnosed. Medical records of dogs with PDH that were treated with ketoconazole were examined. Data collected from each record included signalment, clinical signs, results of ACTH stimulation tests before and after treatment with ketoconazole, serum alkaline phosphatase (ALP) and alanine aminotransferase (ALT) activities, dosage of ketoconazole, clinical response, and survival time. 43 of 48 (90%) dogs had evidence of clinical improvement during the treatment period. In all dogs, treatment with ketoconazole resulted in significantly lower serum cortisol concentrations as measured before and after ACTH stimulation testing; 69% (33/48) of serum cortisol concentrations measured after ACTH stimulation were within the reference range. Serum ALP and ALT activities significantly decreased after treatment with ketoconazole. Survival time after diagnosis of PDH ranged from 2 to 61 months (mean, 26.9 months; median, 25 months). Ketoconazole was a safe and effective option for treating dogs with PDH. Additional research is needed to evaluate the effects of long-term treatment with ketoconazole on adrenal glands.
Monitoring of Engineering Buildings Behaviour Within the Disaster Management System
NASA Astrophysics Data System (ADS)
Oku Topal, G.; Gülal, E.
2017-11-01
The Disaster management aims to prevent events that result in disaster or to reduce their losses. Monitoring of engineering buildings, identification of unusual movements and taking the necessary precautions are very crucial for determination of the disaster risk so possible prevention could be taken to reduce big loss. Improving technology, increasing population due to increased construction and these areas largest economy lead to offer damage detection strategies. Structural Health Monitoring (SHM) is the most effective of these strategies. SHM research is very important to maintain all this structuring safely. The purpose of structural monitoring is determining in advance of possible accidents and taking necessary precaution. In this paper, determining the behaviour of construction using Global Positioning System (GPS) is investigated. For this purpose shaking table tests were performed. Shaking table was moved at different amplitude and frequency aiming to determine these movement with a GPS measuring system. The obtained data were evaluated by analysis of time series and Fast Fourier Transformation techniques and the frequency and amplitude values are calculated. By examining the results of the tests made, it will be determined whether the GPS measurement method can accurately detect the movements of the engineering structures.
Sodium Heat Pipe Module Processing For the SAFE-100 Reactor Concept
NASA Technical Reports Server (NTRS)
Martin, James; Salvail, Pat
2003-01-01
To support development and hardware-based testing of various space reactor concepts, the Early Flight Fission-Test Facility (EFF-TF) team established a specialized glove box unit with ancillary systems to handle/process alkali metals. Recently, these systems have been commissioned with sodium supporting the fill of stainless steel heat pipe modules for use with a 100 kW thermal heat pipe reactor design. As part of this effort, procedures were developed and refined to govern each segment of the process covering: fill, leak check, vacuum processing, weld closeout, and final "wet in". A series of 316 stainless steel modules, used as precursors to the actual 321 stainless steel modules, were filled with 35 +/- 1 grams of sodium using a known volume canister to control the dispensed mass. Each module was leak checked to less than10(exp -10) std cc/sec helium and vacuum conditioned at 250 C to assist in the removal of trapped gases. A welding procedure was developed to close out the fill stem preventing external gases from entering the evacuated module. Finally the completed modules were vacuum fired at 750 C allowing the sodium to fully wet the internal surface and wick structure of the heat pipe module.
Sodium Heat Pipe Module Processing For the SAFE-100 Reactor Concept
NASA Astrophysics Data System (ADS)
Martin, James; Salvail, Pat
2004-02-01
To support development and hardware-based testing of various space reactor concepts, the Early Flight Fission-Test Facility (EFF-TF) team established a specialized glove box unit with ancillary systems to handle/process alkali metals. Recently, these systems have been commissioned with sodium supporting the fill of stainless steel heat pipe modules for use with a 100 kW thermal heat pipe reactor design. As part of this effort, procedures were developed and refined to govern each segment of the process covering: fill, leak check, vacuum processing, weld closeout, and final ``wet in''. A series of 316 stainless steel modules, used as precursors to the actual 321 stainless steel modules, were filled with 35 +/-1 grams of sodium using a known volume canister to control the dispensed mass. Each module was leak checked to <10-10 std cc/sec helium and vacuum conditioned at 250 °C to assist in the removal of trapped gases. A welding procedure was developed to close out the fill stem preventing external gases from entering the evacuated module. Finally the completed modules were vacuum fired at 750 °C allowing the sodium to fully wet the internal surface and wick structure of the heat pipe module.
Spent Pot Lining Characterization Framework
NASA Astrophysics Data System (ADS)
Ospina, Gustavo; Hassan, Mohamed I.
2017-09-01
Spent pot lining (SPL) management represents a major concern for aluminum smelters. There are two key elements for spent pot lining management: recycling and safe storage. Spent pot lining waste can potentially have beneficial uses in co-firing in cement plants. Also, safe storage of SPL is of utmost importance. Gas generation of SPL reaction with water and ignition sensitivity must be studied. However, determining the feasibility of SPL co-firing and developing the required procedures for safe storage rely on determining experimentally all the necessary SPL properties along with the appropriate test methods, recognized by emissions standards and fire safety design codes. The applicable regulations and relevant SPL properties for this purpose are presented along with the corresponding test methods.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-24
...; Analysis and Sampling Procedures AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY... Contaminants Under the Safe Drinking Water Act; Analysis and Sampling Procedures. 75 FR 32295. June 8, 2010...
Measuring colour rivalry suppression in amblyopia.
Hofeldt, T S; Hofeldt, A J
1999-11-01
To determine if the colour rivalry suppression is an index of the visual impairment in amblyopia and if the stereopsis and fusion evaluator (SAFE) instrument is a reliable indicator of the difference in visual input from the two eyes. To test the accuracy of the SAFE instrument for measuring the visual input from the two eyes, colour rivalry suppression was measured in six normal subjects. A test neutral density filter (NDF) was placed before one eye to induce a temporary relative afferent defect and the subject selected the NDF before the fellow eye to neutralise the test NDF. In a non-paediatric private practice, 24 consecutive patients diagnosed with unilateral amblyopia were tested with the SAFE. Of the 24 amblyopes, 14 qualified for the study because they were able to fuse images and had no comorbid disease. The relation between depth of colour rivalry suppression, stereoacuity, and interocular difference in logMAR acuity was analysed. In normal subjects, the SAFE instrument reversed temporary defects of 0.3 to 1. 8 log units to within 0.6 log units. In amblyopes, the NDF to reverse colour rivalry suppression was positively related to interocular difference in logMAR acuity (beta=1.21, p<0.0001), and negatively related to stereoacuity (beta=-0.16, p=0.019). The interocular difference in logMAR acuity was negatively related to stereoacuity (beta=-0.13, p=0.009). Colour rivalry suppression as measured with the SAFE was found to agree closely with the degree of visual acuity impairment in non-paediatric patients with amblyopia.
Embracing Safe Ground Test Facility Operations and Maintenance
NASA Technical Reports Server (NTRS)
Dunn, Steven C.; Green, Donald R.
2010-01-01
Conducting integrated operations and maintenance in wind tunnel ground test facilities requires a balance of meeting due dates, efficient operation, responsiveness to the test customer, data quality, effective maintenance (relating to readiness and reliability), and personnel and facility safety. Safety is non-negotiable, so the balance must be an "and" with other requirements and needs. Pressure to deliver services faster at increasing levels of quality in under-maintained facilities is typical. A challenge for management is to balance the "need for speed" with safety and quality. It s especially important to communicate this balance across the organization - workers, with a desire to perform, can be tempted to cut corners on defined processes to increase speed. Having a lean staff can extend the time required for pre-test preparations, so providing a safe work environment for facility personnel and providing good stewardship for expensive National capabilities can be put at risk by one well-intending person using at-risk behavior. This paper documents a specific, though typical, operational environment and cites management and worker safety initiatives and tools used to provide a safe work environment. Results are presented and clearly show that the work environment is a relatively safe one, though still not good enough to keep from preventing injury. So, the journey to a zero injury work environment - both in measured reality and in the minds of each employee - continues. The intent of this paper is to provide a benchmark for others with operational environments and stimulate additional sharing and discussion on having and keeping a safe work environment.
Classen, Sherrilene; Winter, Sandra M.; Velozo, Craig A.; Bédard, Michel; Lanford, Desiree N.; Brumback, Babette; Lutz, Barbara J.
2010-01-01
OBJECTIVE We report on item development and validity testing of a self-report older adult safe driving behaviors measure (SDBM). METHOD On the basis of theoretical frameworks (Precede–Proceed Model of Health Promotion, Haddon’s matrix, and Michon’s model), existing driving measures, and previous research and guided by measurement theory, we developed items capturing safe driving behavior. Item development was further informed by focus groups. We established face validity using peer reviewers and content validity using expert raters. RESULTS Peer review indicated acceptable face validity. Initial expert rater review yielded a scale content validity index (CVI) rating of 0.78, with 44 of 60 items rated ≥0.75. Sixteen unacceptable items (≤0.5) required major revision or deletion. The next CVI scale average was 0.84, indicating acceptable content validity. CONCLUSION The SDBM has relevance as a self-report to rate older drivers. Future pilot testing of the SDBM comparing results with on-road testing will define criterion validity. PMID:20437917
Stochastic approaches for time series forecasting of boron: a case study of Western Turkey.
Durdu, Omer Faruk
2010-10-01
In the present study, a seasonal and non-seasonal prediction of boron concentrations time series data for the period of 1996-2004 from Büyük Menderes river in western Turkey are addressed by means of linear stochastic models. The methodology presented here is to develop adequate linear stochastic models known as autoregressive integrated moving average (ARIMA) and multiplicative seasonal autoregressive integrated moving average (SARIMA) to predict boron content in the Büyük Menderes catchment. Initially, the Box-Whisker plots and Kendall's tau test are used to identify the trends during the study period. The measurements locations do not show significant overall trend in boron concentrations, though marginal increasing and decreasing trends are observed for certain periods at some locations. ARIMA modeling approach involves the following three steps: model identification, parameter estimation, and diagnostic checking. In the model identification step, considering the autocorrelation function (ACF) and partial autocorrelation function (PACF) results of boron data series, different ARIMA models are identified. The model gives the minimum Akaike information criterion (AIC) is selected as the best-fit model. The parameter estimation step indicates that the estimated model parameters are significantly different from zero. The diagnostic check step is applied to the residuals of the selected ARIMA models and the results indicate that the residuals are independent, normally distributed, and homoscadastic. For the model validation purposes, the predicted results using the best ARIMA models are compared to the observed data. The predicted data show reasonably good agreement with the actual data. The comparison of the mean and variance of 3-year (2002-2004) observed data vs predicted data from the selected best models show that the boron model from ARIMA modeling approaches could be used in a safe manner since the predicted values from these models preserve the basic statistics of observed data in terms of mean. The ARIMA modeling approach is recommended for predicting boron concentration series of a river.
Design of a safe cylindrical lithium/thionyl chloride cell
NASA Technical Reports Server (NTRS)
Johnson, D. H.
1983-01-01
Cell design criteria were established which can result in a safe lithium/thionyl chloride cell. A cell vent, a low area internal anode cell, cell balance and composition of the cathode-electrolyte solution were found to be important factors in the design of a safe cell. In addition to routine testing, both undischarged and discharged cells were subjected to electrical abuse, environmental abuse and mechanical abuse without disassembly.
Chaffin, Mark; Bard, David; Bigfoot, Dolores Subia; Maher, Erin J
2012-08-01
In a statewide implementation, the manualized SafeCare home-based model was effective in reducing child welfare recidivism and producing high client satisfaction. Concerns about the effectiveness and acceptability of structured, manualized models with American Indians have been raised in the literature, but have rarely been directly tested. This study tests recidivism reduction equivalency and acceptability among American Indian parents. A subpopulation of 354 American Indian parents was drawn from a larger trial that compared services with versus without modules of the SafeCare model. Outcomes were 6-year recidivism, pre/post/follow-up measures of depression and child abuse potential, and posttreatment consumer ratings of working alliance, service satisfaction, and cultural competency. Recidivism reduction among American Indian parents was found to be equivalent for cases falling within customary SafeCare inclusion criteria. When extended to cases outside customary inclusion boundaries, there was no apparent recidivism advantage or disadvantage. Contrary to concerns, SafeCare had higher consumer ratings of cultural competency, working alliance, service quality, and service benefit. Findings support using SafeCare with American Indians parents who meet customary SafeCare inclusion criteria. Findings do not support concerns in the literature that a manualized, structured, evidence-based model might be less effective or culturally unacceptable for American Indians.
Chaffin, Mark; Bard, David; Bigfoot, Dolores Subia; Maher, Erin J.
2015-01-01
In a statewide implementation, the manualized SafeCare home–based model was effective in reducing child welfare recidivism and producing high client satisfaction. Concerns about the effectiveness and acceptability of structured, manualized models with American Indians have been raised in the literature, but have rarely been directly tested. This study tests recidivism reduction equivalency and acceptability among American Indian parents. A subpopulation of 354 American Indian parents was drawn from a larger trial that compared services with versus without modules of the SafeCare model. Outcomes were 6-year recidivism, pre/post/follow-up measures of depression and child abuse potential, and posttreatment consumer ratings of working alliance, service satisfaction, and cultural competency. Recidivism reduction among American Indian parents was found to be equivalent for cases falling within customary SafeCare inclusion criteria. When extended to cases outside customary inclusion boundaries, there was no apparent recidivism advantage or disadvantage. Contrary to concerns, SafeCare had higher consumer ratings of cultural competency, working alliance, service quality, and service benefit. Findings support using SafeCare with American Indians parents who meet customary SafeCare inclusion criteria. Findings do not support concerns in the literature that a manualized, structured, evidence-based model might be less effective or culturally unacceptable for American Indians. PMID:22927674
... Staying Safe Videos for Educators Search English Español Genetic Testing KidsHealth / For Parents / Genetic Testing What's in ... blood, skin, bone, or other tissue is needed. Genetic Testing During Pregnancy For genetic testing before birth, ...
Perceived neighborhood safety and sleep quality: a global analysis of six countries.
Hill, Terrence D; Trinh, Ha Ngoc; Wen, Ming; Hale, Lauren
2016-02-01
Building on previous North American and European studies of neighborhood context and sleep quality, we tested whether several self-reported sleep outcomes (sleep duration, insomnia symptoms, sleepiness, lethargy, and overall sleep quality) vary according to the level of perceived neighborhood safety in six countries: Mexico, Ghana, South Africa, India, China, and Russia. Using data (n = 39,590) from Wave I of the World Health Organization's Longitudinal Study on Global Ageing and Adult Health (2007-2010), we estimated a series of multinomial and binary logistic regression equations to model each sleep outcome within each country. Taken together, our results show that respondents who feel safe from crime and violence in their neighborhoods tend to exhibit more favorable sleep outcomes than respondents who feel less safe. This general pattern is especially pronounced in China and Russia, moderately evident in Mexico, Ghana, and South Africa, and sporadic in India. Perceptions of neighborhood safety are strongly associated with insomnia symptoms and poor sleep quality (past 30 days), moderately associated with sleepiness, lethargy, and poor sleep quality (past 2 days), and inconsistently associated with sleep duration (past two days). We show that perceived neighborhood safety is associated with more favorable self-reported sleep outcomes in six understudied countries. Additional research is needed to replicate our findings using longitudinal data, more reliable neighborhood measures, and more direct measures of sleep quality in these and other regions of the world. Copyright © 2014 Elsevier B.V. All rights reserved.
D'Andrea, Giancarlo; Familiari, Pietro; Di Lauro, Antonio; Angelini, Albina; Sessa, Giovanni
2016-03-01
Language dysfunction, visual deficit, numeracy impairment, and Gerstmann syndrome often occur in the cortical area; furthermore, the subcortical white matter is the inviolable limit of "functional neurosurgery." Preoperative functional magnetic resonance imaging (fMRI) and tractography are capable of providing the data required for safe "surgical planning" at both the cortical and subcortical levels. We report our experience regarding high-grade gliomas affecting the dominant angular gyrus (AG), supramarginal gyrus (SMG), intraparietal sulcus (IPS), and their respective subcortical areas using intraoperative MRI and diffusion tensor imaging (DTI). Retrospectively, we reviewed a consecutive series of 27 patients operated in a BrainSuite for high-grade intraparenchymal tumors of the left posterior temporoparietal junction. We included tumors involving the dominant AG, SMG, and/or IPS and the subcortical course of arcuate fasciculus (AF) and all the patients who underwent preoperative fMRI and DTI to localize the AF and the eloquent cortical areas. Just after craniotomy, new volumetric MRI and DTI verified and corrected possible brain shift. After the gross total resection was carried out, and before approaching the residual mass close to the white matter tract, an intraoperative MRI was again performed. We operated on 27 patients, 15 males and 12 females, whose diagnosis was always high-grade glioma. During the preoperative neurologic examination, 6 patients were asymptomatic; 3 presented a Gerstmann syndrome; 16 showed dysphasic disturbances, 6 of which were associated with visual field deficits; and 2 showed weakness of the right limb. Our results suggest that this approach is completely safe and effective as an alternative to awake surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chichester, Heather Jean MacLean; Hayes, Steven Lowe; Dempsey, Douglas
This report summarizes the objectives of the current irradiation testing activities being undertaken by the Advanced Fuels Campaign relative to supporting the development and demonstration of innovative design features for metallic fuels in order to realize reliable performance to ultra-high burnups. The AFC-3 and AFC-4 test series are nearing completion; the experiments in this test series that have been completed or are in progress are reviewed and the objectives and test matrices for the final experiments in these two series are defined. The objectives, testing strategy, and test parameters associated with a future AFC test series, AFC-5, are documented. Finally,more » the future intersections and/or synergies of the AFC irradiation testing program with those of the TREAT transient testing program, emerging needs of proposed Versatile Test Reactor concepts, and the Joint Fuel Cycle Study program’s Integrated Recycle Test are discussed.« less
NASA Technical Reports Server (NTRS)
Pavlock, Kate M.
2011-01-01
The National Aeronautics and Space Administration's Dryden Flight Research Center completed flight testing of adaptive controls research on the Full-Scale Advance Systems Testbed (FAST) in January of 2011. The research addressed technical challenges involved with reducing risk in an increasingly complex and dynamic national airspace. Specific challenges lie with the development of validated, multidisciplinary, integrated aircraft control design tools and techniques to enable safe flight in the presence of adverse conditions such as structural damage, control surface failures, or aerodynamic upsets. The testbed is an F-18 aircraft serving as a full-scale vehicle to test and validate adaptive flight control research and lends a significant confidence to the development, maturation, and acceptance process of incorporating adaptive control laws into follow-on research and the operational environment. The experimental systems integrated into FAST were designed to allow for flexible yet safe flight test evaluation and validation of modern adaptive control technologies and revolve around two major hardware upgrades: the modification of Production Support Flight Control Computers (PSFCC) and integration of two, fourth-generation Airborne Research Test Systems (ARTS). Post-hardware integration verification and validation provided the foundation for safe flight test of Nonlinear Dynamic Inversion and Model Reference Aircraft Control adaptive control law experiments. To ensure success of flight in terms of cost, schedule, and test results, emphasis on risk management was incorporated into early stages of design and flight test planning and continued through the execution of each flight test mission. Specific consideration was made to incorporate safety features within the hardware and software to alleviate user demands as well as into test processes and training to reduce human factor impacts to safe and successful flight test. This paper describes the research configuration, experiment functionality, overall risk mitigation, flight test approach and results, and lessons learned of adaptive controls research of the Full-Scale Advanced Systems Testbed.
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Hip KidsHealth / For Parents / X-Ray Exam: Hip What's in this article? What ... Have Questions Print What It Is A hip X-ray is a safe and painless test that ...
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Forearm KidsHealth / For Parents / X-Ray Exam: Forearm What's in this article? What ... Have Questions Print What It Is A forearm X-ray is a safe and painless test that ...
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Ankle KidsHealth / For Parents / X-Ray Exam: Ankle What's in this article? What ... Have Questions Print What It Is An ankle X-ray is a safe and painless test that ...
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: Foot What's in this article? What ... Have Questions Print What It Is A foot X-ray is a safe and painless test that ...
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Wrist KidsHealth / For Parents / X-Ray Exam: Wrist What's in this article? What ... Have Questions Print What It Is A wrist X-ray is a safe and painless test that ...
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Finger KidsHealth / For Parents / X-Ray Exam: Finger What's in this article? What ... Have Questions Print What It Is A finger X-ray is a safe and painless test that ...
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Pelvis KidsHealth / For Parents / X-Ray Exam: Pelvis What's in this article? What ... Have Questions Print What It Is A pelvis X-ray is a safe and painless test that ...
Managing the Mars Science Laboratory Thermal Vacuum Test for Safety and Success
NASA Technical Reports Server (NTRS)
Evans, Jordan P.
2010-01-01
The Mars Science Laboratory is a NASA/JPL mission to send the next generation of rover to Mars. Originally slated for launch in 2009, development problems led to a delay in the project until the next launch opportunity in 2011. Amidst the delay process, the Launch/Cruise Solar Thermal Vacuum Test was undertaken as risk reduction for the project. With varying maturity and capabilities of the flight and ground systems, undertaking the test in a safe manner presented many challenges. This paper describes the technical and management challenges and the actions undertaken that led to the ultimate safe and successful execution of the test.
Kadin, Michael R.; Thompson, Ronald W.
1974-01-01
Since the introduction of “staging laparotomy” (to determine the disease's stage) in assessing Hodgkin's disease, some observers have argued that lymphangiography could be safely omitted in the initial diagnostic evaluation. To test these opinions a series of 75 patients with Hodgkin's disease who had a staging laparotomy and histological correlation with lymphangiograms was reviewed. Of 16 examinations with positive results, one proved to be a false positive. Of the 14 examinations with equivocal results, one proved histologically positive. In the remaining 45 lymphangiograms, five were falsely negative. In all five of these patients abdominal lymph nodes were involved, but in areas that do not routinely opacify on lower extremity lymphangiography. The overall accuracy was 90 percent. Therapeutically, the lymphangiogram permits accurate planning for treatment by radiation therapy so that all known disease is treated and yet bone marrow is not excessively irradiated. Changes in lymph node architecture after therapy provide valuable information as to regression of the disease or signs of its early recurrence. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7. PMID:4816398
Galy, Bertrand; Lan, André
2018-03-01
Among the many occupational risks construction workers encounter every day falling from a height is the most dangerous. The objective of this article is to propose a simple analytical design method for horizontal lifelines (HLLs) that considers anchorage flexibility. The article presents a short review of the standards and regulations/acts/codes concerning HLLs in Canada the USA and Europe. A static analytical approach is proposed considering anchorage flexibility. The analytical results are compared with a series of 42 dynamic fall tests and a SAP2000 numerical model. The experimental results show that the analytical method is a little conservative and overestimates the line tension in most cases with a maximum of 17%. The static SAP2000 results show a maximum 2.1% difference with the analytical method. The analytical method is accurate enough to safely design HLLs and quick design abaci are provided to allow the engineer to make quick on-site verification if needed.
Smith, Roger; Patel, Vipul; Satava, Richard
2014-09-01
There is a need for a standardized curriculum for training and assessment of robotic surgeons to proficiency, followed by high-stakes testing (HST) for certification. To standardize the curriculum and certification of robotic surgeons, a series of consensus conferences attended by 14 leading international surgical societies have been used to compile the outcomes measures and curriculum that should form the basis for a Fundamentals of Robotic Surgery (FRS) programme. A set of 25 outcomes measures and a curriculum for teaching the skills needed to safely use current generation surgical robotic systems has been developed and accepted by a committee of experienced robotic surgeons across 14 specialties. A standardized process for certifying the skills of a robotic surgeon has begun to emerge. The work described here documents both the processes used for developing educational material and the educational content of a robotic curriculum. Copyright © 2013 John Wiley & Sons, Ltd.
Brain, A I
1991-01-01
The history of the invention and development of the Laryngeal Mask in the East End of London during the years 1981-88 is briefly described. The concept evolved from home-made prototypes built from the Goldman Dental Mask through a complex series of one-off latex models culminating in a primitive factory-made silicone cuff in 1986. This work defined the design parameters necessary to reconcile the needs for safety, reliability and ease of insertion while at the same time exploring the limits to possible use. In early 1988 the final version was tested by the inventor who had by this time used the device in more than 7500 patients undergoing routine surgery. From this experience a number of important lessons were learned relating to safe and effective use, which are summarized in the inventor's Instruction Manual. The importance of referring to this volume before use is stressed.
Further Investigations of Hypersonic Engine Seals
NASA Technical Reports Server (NTRS)
Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; DeMange, Jeffrey J.
2004-01-01
Durable, flexible sliding seals are required in advanced hypersonic engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures of 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA's Glenn Research Center is developing advanced seals and preloading devices to overcome these shortfalls. An advanced ceramic wafer seal design and two silicon nitride compression spring designs were evaluated in a series of compression, scrub, and flow tests. Silicon nitride wafer seals survived 2000 in. (50.8 m) of scrubbing at 2000 F against a silicon carbide rub surface with no chips or signs of damage. Flow rates measured for the wafers before and after scrubbing were almost identical and were up to 32 times lower than those recorded for the best braided rope seal flow blockers. Silicon nitride compression springs showed promise conceptually as potential seal preload devices to help maintain seal resiliency.
Practicing safe cell culture: applied process designs for minimizing virus contamination risk.
Kiss, Robert D
2011-01-01
CONFERENCE PROCEEDING Proceedings of the PDA/FDA Adventitious Viruses in Biologics: Detection and Mitigation Strategies Workshop in Bethesda, MD, USA; December 1-3, 2010 Guest Editors: Arifa Khan (Bethesda, MD), Patricia Hughes (Bethesda, MD) and Michael Wiebe (San Francisco, CA) Genentech responded to a virus contamination in its biologics manufacturing facility by developing and implementing a series of barriers specifically designed to prevent recurrence of this significant and impactful event. The barriers included steps to inactivate or remove potential virus particles from the many raw materials used in cell culture processing. Additionally, analytical testing barriers provided protection of the downstream processing areas should a culture contamination occur, and robust virus clearance capability provided further assurance of virus safety should a low level contamination go undetected. This conference proceeding will review Genentech's approach, and lessons learned, in minimizing virus contamination risk in cell culture processes through multiple layers of targeted barriers designed to deliver biologics products with high success rates.
Innovative Power Wheelchair Control Interface: A Proof-of-Concept Study
Romero, Sergio; Prather, Emily; Ramroop, Marisa; Slaibe, Emmy; Christensen, Matthew
2016-01-01
Some people without independent mobility are candidates for powered mobility but are unable to use a traditional power wheelchair joystick. This proof-of-concept study tested and further developed an innovative method of driving power wheelchairs for people whose impairments prevent them from operating commercial wheelchair controls. Our concept, Self-referenced Personal Orthotic Omni-purpose Control Interface (SPOOCI), is distinguished by referencing the control sensor not to the wheelchair frame but instead to the adjacent proximal lower-extremity segment via a custom-formed orthosis. Using a descriptive case-series design, we compared the pre–post functional power wheelchair driving skill data of 4 participants, measured by the Power Mobility Program, using descriptive analyses. The intervention consisted of standard-care power wheelchair training during 12 outpatient occupational or physical therapy sessions. All 4 participants who completed the 12-wk intervention improved their functional power wheelchair driving skills using SPOOCI, but only 3 were deemed safe to continue with power wheelchair driving. PMID:26943118
Non-parametric characterization of long-term rainfall time series
NASA Astrophysics Data System (ADS)
Tiwari, Harinarayan; Pandey, Brij Kishor
2018-03-01
The statistical study of rainfall time series is one of the approaches for efficient hydrological system design. Identifying, and characterizing long-term rainfall time series could aid in improving hydrological systems forecasting. In the present study, eventual statistics was applied for the long-term (1851-2006) rainfall time series under seven meteorological regions of India. Linear trend analysis was carried out using Mann-Kendall test for the observed rainfall series. The observed trend using the above-mentioned approach has been ascertained using the innovative trend analysis method. Innovative trend analysis has been found to be a strong tool to detect the general trend of rainfall time series. Sequential Mann-Kendall test has also been carried out to examine nonlinear trends of the series. The partial sum of cumulative deviation test is also found to be suitable to detect the nonlinear trend. Innovative trend analysis, sequential Mann-Kendall test and partial cumulative deviation test have potential to detect the general as well as nonlinear trend for the rainfall time series. Annual rainfall analysis suggests that the maximum changes in mean rainfall is 11.53% for West Peninsular India, whereas the maximum fall in mean rainfall is 7.8% for the North Mountainous Indian region. The innovative trend analysis method is also capable of finding the number of change point available in the time series. Additionally, we have performed von Neumann ratio test and cumulative deviation test to estimate the departure from homogeneity. Singular spectrum analysis has been applied in this study to evaluate the order of departure from homogeneity in the rainfall time series. Monsoon season (JS) of North Mountainous India and West Peninsular India zones has higher departure from homogeneity and singular spectrum analysis shows the results to be in coherence with the same.
Public speaking for the healthcare professional: Part III--after the program.
Baum, Neil
2012-01-01
Public speaking is one of life's greatest fears for many people. However, with practice, repetition, and planning, you can safely leave your comfort zone and make a presentation that will engage the members of the audience, attract their attention, and cause them to take action on your material. This third article in the series will discuss what to do after the last slide is shown.
ERIC Educational Resources Information Center
Newcomer, Lori L.; Lewis, Timothy J.; Powers, Lisa J.
Elementary schools can play an important role in early identification of and intervention for children with problem behavior by creating the infrastructure to provide preventive, proactive supports for all students. This monograph provides an overview of key features of effective school-wide systems of positive behavior support (PBS) at the…
Treating Clostridium difficile Infection with Fecal Microbiota Transplantation
Bakken, Johan S.; Borody, Thomas; Brandt, Lawrence J.; Brill, Joel V.; Demarco, Daniel C.; Franzos, Marc Alaric; Kelly, Colleen; Khoruts, Alexander; Louie, Thomas; Martinelli, Lawrence P.; Moore, Thomas A.; Russell, George; Surawicz, Christina
2011-01-01
Clostridium difficile infection is increasing in incidence, severity, and mortality. Treatment options are limited and appear to be losing efficacy. Recurrent disease is especially challenging; extended treatment with oral vancomycin is becoming increasingly common but is expensive. Fecal microbiota transplantation (FMT) is safe, inexpensive, and effective; according to case and small series reports, about 90% of patients are cured. We discuss the rationale, methods, and use of FMT. PMID:21871249
ESTIMATION OF EXPOSURE DOSES FOR THE SAFE MANAGEMENT OF NORM WASTE DISPOSAL.
Jeong, Jongtae; Ko, Nak Yul; Cho, Dong-Keun; Baik, Min Hoon; Yoon, Ki-Hoon
2018-03-16
Naturally occurring radioactive materials (NORM) wastes with different radiological characteristics are generated in several industries. The appropriate options for NORM waste management including disposal options should be discussed and established based on the act and regulation guidelines. Several studies calculated the exposure dose and mass of NORM waste to be disposed in landfill site by considering the activity concentration level and exposure dose. In 2012, the Korean government promulgated an act on the safety control of NORM around living environments to protect human health and the environment. For the successful implementation of this act, we suggest a reference design for a landfill for the disposal of NORM waste. Based on this reference landfill, we estimate the maximum exposure doses and the relative impact of each pathway to exposure dose for three scenarios: a reference scenario, an ingestion pathway exclusion scenario, and a low leach rate scenario. Also, we estimate the possible quantity of NORM waste disposal into a landfill as a function of the activity concentration level of U series, Th series and 40K and two kinds of exposure dose levels, 1 and 0.3 mSv/y. The results of this study can be used to support the establishment of technical bases of the management strategy for the safe disposal of NORM waste.
2014-01-01
Background Internationally there is policy support for the introduction of methadone maintenance programmes into prison settings. Increasingly GPs are encouraged to undertake this work although concerns remain regarding the safety of such programmes. This study sought to evaluate the impact and safety of the introduction of a general practitioner with a special interest (GPsi) in substance misuse led methadone prescribing service into a UK prison between 2003 and 2010. Methods Time series analysis of secondary prescribing data pertaining to opiate maintenance therapies, opiate detoxification therapies and opiate related deaths for the time period 2003 to 2010. Results Results show that following introduction of a GPsi in substance misuse there was a statistically significant increase in both methadone maintenance and detoxification treatments. Over time the rate of methadone maintenance prescribing plateaued with a corresponding decrease in the rate of methadone detoxification prescribing. There were no methadone related deaths in prison over the study period. Conclusion The phased introduction of opiate replacement therapies into a busy remand prison did not result in any deaths within the prison for which opiate replacement was identified as the cause. GPsi led opiate prescribing programmes can be introduced safely into secure environments. PMID:24712316
Performance testing of collision-avoidance system for power wheelchairs.
Lopresti, Edmund F; Sharma, Vinod; Simpson, Richard C; Mostowy, L Casimir
2011-01-01
The Drive-Safe System (DSS) is a collision-avoidance system for power wheelchairs designed to support people with mobility impairments who also have visual, upper-limb, or cognitive impairments. The DSS uses a distributed approach to provide an add-on, shared-control, navigation-assistance solution. In this project, the DSS was tested for engineering goals such as sensor coverage, maximum safe speed, maximum detection distance, and power consumption while the wheelchair was stationary or driven by an investigator. Results indicate that the DSS provided uniform, reliable sensor coverage around the wheelchair; detected obstacles as small as 3.2 mm at distances of at least 1.6 m; and attained a maximum safe speed of 4.2 km/h. The DSS can drive reliably as close as 15.2 cm from a wall, traverse doorways as narrow as 81.3 cm without interrupting forward movement, and reduce wheelchair battery life by only 3%. These results have implications for a practical system to support safe, independent mobility for veterans who acquire multiple disabilities during Active Duty or later in life. These tests indicate that a system utilizing relatively low cost ultrasound, infrared, and force sensors can effectively detect obstacles in the vicinity of a wheelchair.
NASA Battery Working Group - 2007-2008: Battery Task Summary Report
NASA Technical Reports Server (NTRS)
Manzo, Michelle
2008-01-01
This presentation provides a summary of the 2007-2008 NASA Battery Working Group efforts completed in support of the NASA Engineering Safety Center (NESC). The effort covered a series of pro-active tasks that address the following: Binding Procurements -- guidelines related to requirements for the battery system that should be considered at the time of contract award Wet Life of Ni-H2 Batteries -- issues/strategies for effective storage and impact of long-term storage on performance and life Generic Guidelines for Lithium-ion Safety, Handling and Qualification -- Standardized approaches developed and risk assessments (1) Lithium-ion Performance Assessment -- survey of manufacturers and capabilities to meet mission needs. Guidelines document generated (2) Conditions Required for using Pouch Cells in Aerospace Missions -- focus on corrosion, thermal excursions and long-term performance issues. Document defining requirements to maintain performance and life (3) High Voltage Risk Assessment -- focus on safety and abuse tolerance of battery module assemblies. Recommendations of features required for safe implementation (4) Procedure for Determination of Safe Charge Rates -- evaluation of various cell chemistries and recommendation of safe operating regimes for specific cell designs
Human Spaceflight Safety for the Next Generation on Orbital Space Systems
NASA Technical Reports Server (NTRS)
Mango, Edward J.
2011-01-01
The National Aeronautics and Space Administration (NASA) Commercial Crew Program (CCP) has been chartered to facilitate the development of a United States (U.S.) commercial crew space transportation capability with the goal of achieving safe, reliable, and cost effective access to and from low Earth orbit (LEO) and the International Space Station (ISS) as soon as possible. Once the capability is matured and is available to the Government and other customers, NASA expects to purchase commercial services to meet its ISS crew rotation and emergency return objectives. The primary role of the CCP is to enable and ensure safe human spaceflight and processes for the next generation of earth orbital space systems. The architecture of the Program delineates the process for investment performance in safe orbital systems, Crew Transportation System (CTS) certification, and CTS Flight Readiness. A series of six technical documents build up the architecture to address the top-level CTS requirements and standards. They include Design Reference Missions, with the near term focus on ISS crew services, Certification and Service Requirements, Technical Management Processes, and Technical and Operations Standards Evaluation Processes.
Endoscopic third ventriculostomy for hydrocephalus in brainstem glioma: a case series.
Kobayashi, Natsuki; Ogiwara, Hideki
2016-07-01
A brainstem glioma is an incurable brain tumor that can be complicated by hydrocephalus. A ventriculoperitoneal (VP) shunt is generally performed for the control of hydrocephalus. This study aimed to reveal the safety and efficacy of an endoscopic third ventriculostomy (ETV) for hydrocephalus in brainstem gliomas. Six patients who had pontine glioma with hydrocephalus underwent an ETV between May 2010 and November 2015. In all the cases, there were one or more symptoms of hydrocephalus (headache, nausea, vomiting, or lethargy). Retrospective review of these patients was performed using the medical records and neuroimagings. The ETV was performed safely and there were no intraoperative complications in all patients. The mean follow-up period was 12.3 months. An immediate symptomatic relief of hydrocephalus and an adequate control of symptoms were achieved without a VP shunt in all patients. The ETV is considered to be an effective and safe procedure for the treatment of hydrocephalus in brainstem gliomas. Determining the ventriculostomy site according to the preoperative MRI in each case is considered to be important for the safe procedure.
Assessment of an Automated Touchdown Detection Algorithm for the Orion Crew Module
NASA Technical Reports Server (NTRS)
Gay, Robert S.
2011-01-01
Orion Crew Module (CM) touchdown detection is critical to activating the post-landing sequence that safe?s the Reaction Control Jets (RCS), ensures that the vehicle remains upright, and establishes communication with recovery forces. In order to accommodate safe landing of an unmanned vehicle or incapacitated crew, an onboard automated detection system is required. An Orion-specific touchdown detection algorithm was developed and evaluated to differentiate landing events from in-flight events. The proposed method will be used to initiate post-landing cutting of the parachute riser lines, to prevent CM rollover, and to terminate RCS jet firing prior to submersion. The RCS jets continue to fire until touchdown to maintain proper CM orientation with respect to the flight path and to limit impact loads, but have potentially hazardous consequences if submerged while firing. The time available after impact to cut risers and initiate the CM Up-righting System (CMUS) is measured in minutes, whereas the time from touchdown to RCS jet submersion is a function of descent velocity, sea state conditions, and is often less than one second. Evaluation of the detection algorithms was performed for in-flight events (e.g. descent under chutes) using hi-fidelity rigid body analyses in the Decelerator Systems Simulation (DSS), whereas water impacts were simulated using a rigid finite element model of the Orion CM in LS-DYNA. Two touchdown detection algorithms were evaluated with various thresholds: Acceleration magnitude spike detection, and Accumulated velocity changed (over a given time window) spike detection. Data for both detection methods is acquired from an onboard Inertial Measurement Unit (IMU) sensor. The detection algorithms were tested with analytically generated in-flight and landing IMU data simulations. The acceleration spike detection proved to be faster while maintaining desired safety margin. Time to RCS jet submersion was predicted analytically across a series of simulated Orion landing conditions. This paper details the touchdown detection method chosen and the analysis used to support the decision.
Advanced technologies for scalable ATLAS conditions database access on the grid
NASA Astrophysics Data System (ADS)
Basset, R.; Canali, L.; Dimitrov, G.; Girone, M.; Hawkings, R.; Nevski, P.; Valassi, A.; Vaniachine, A.; Viegas, F.; Walker, R.; Wong, A.
2010-04-01
During massive data reprocessing operations an ATLAS Conditions Database application must support concurrent access from numerous ATLAS data processing jobs running on the Grid. By simulating realistic work-flow, ATLAS database scalability tests provided feedback for Conditions Db software optimization and allowed precise determination of required distributed database resources. In distributed data processing one must take into account the chaotic nature of Grid computing characterized by peak loads, which can be much higher than average access rates. To validate database performance at peak loads, we tested database scalability at very high concurrent jobs rates. This has been achieved through coordinated database stress tests performed in series of ATLAS reprocessing exercises at the Tier-1 sites. The goal of database stress tests is to detect scalability limits of the hardware deployed at the Tier-1 sites, so that the server overload conditions can be safely avoided in a production environment. Our analysis of server performance under stress tests indicates that Conditions Db data access is limited by the disk I/O throughput. An unacceptable side-effect of the disk I/O saturation is a degradation of the WLCG 3D Services that update Conditions Db data at all ten ATLAS Tier-1 sites using the technology of Oracle Streams. To avoid such bottlenecks we prototyped and tested a novel approach for database peak load avoidance in Grid computing. Our approach is based upon the proven idea of pilot job submission on the Grid: instead of the actual query, an ATLAS utility library sends to the database server a pilot query first.
Technicians Manufacture a Nozzle for the Kiwi B-1-B Engine
1964-05-21
Technicians manufacture a nozzle for the Kiwi B-1-B nuclear rocket engine in the Fabrication Shop’s vacuum oven at the National Aeronautics and Space Administration (NASA) Lewis Research Center. The Nuclear Engine for Rocket Vehicle Applications (NERVA) was a joint NASA and Atomic Energy Commission (AEC) endeavor to develop a nuclear-powered rocket for both long-range missions to Mars and as a possible upper-stage for the Apollo Program. The early portion of the program consisted of basic reactor and fuel system research. This was followed by a series of Kiwi reactors built to test basic nuclear rocket principles in a non-flying nuclear engine. The next phase, NERVA, would create an entire flyable engine. The final phase of the program, called Reactor-In-Flight-Test, would be an actual launch test. The AEC was responsible for designing the nuclear reactor and overall engine. NASA Lewis was responsible for developing the liquid-hydrogen fuel system. The turbopump, which pumped the fuels from the storage tanks to the engine, was the primary tool for restarting the engine. The NERVA had to be able to restart in space on its own using a safe preprogrammed startup system. Lewis researchers endeavored to design and test this system. This non-nuclear Kiwi engine, seen here, was being prepared for tests at Lewis’ High Energy Rocket Engine Research Facility (B-1) located at Plum Brook Station. The tests were designed to start an unfueled Kiwi B-1-B reactor and its Aerojet Mark IX turbopump without any external power.
Safety and efficacy of personal care products containing colloidal oatmeal.
Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane
2012-01-01
Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period.
Safety and efficacy of personal care products containing colloidal oatmeal
Criquet, Maryline; Roure, Romain; Dayan, Liliane; Nollent, Virginie; Bertin, Christiane
2012-01-01
Background Colloidal oatmeal is a natural ingredient used in the formulation of a range of personal care products for relief of skin dryness and itchiness. It is also used as an adjunctive product in atopic dermatitis. The safety of personal care products used on vulnerable skin is of particular importance and the risk of developing further skin irritations and/or allergies should be minimized. Methods In a series of studies, we tested the safety of personal care products containing oatmeal (creams, cleansers, lotions) by assessing their irritant/allergenic potential on repeat insult patch testing, in safety-in-use and ocular studies using subjects with nonsensitive and sensitive skin. We also tested the skin moisturizing and repair properties of an oatmeal-containing skin care product for dry skin. Results We found that oatmeal-containing personal care products had very low irritant potential as well as a very low allergenic sensitization potential. Low-level reactions were documented in 1.0% of subjects during the induction phase of repeat insult patch testing; one of 2291 subjects developed a persistent but doubtful low-level reaction involving edema during the challenge phase in repeat insult patch testing. No allergies were reported by 80 subjects after patch testing after in-use application. Sustained skin moisturizing was documented in subjects with dry skin that lasted up to 2 weeks after product discontinuation. Conclusion Our results demonstrate that colloidal oatmeal is a safe and effective ingredient in personal care products. No allergies were reported by consumers of 445,820 products sold during a 3-year period. PMID:23204849
Paratransit Vehicle Test and Evaluation : Volume 3. Handling Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume III) presents the test procedures and results of the handling test series. The test determined the steering and handling characteristics o...
HIV and Young Men Who Have Sex with Men
... other health care organizations to collect data, promote safe and supportive environments, increase HIV/STD testing and treatment in schools ... is available at www.cdc.gov/yrbs. Establish safe and supportive school environments. HIV prevention activities are more likely to have ...
Kipiński, Lech; König, Reinhard; Sielużycki, Cezary; Kordecki, Wojciech
2011-10-01
Stationarity is a crucial yet rarely questioned assumption in the analysis of time series of magneto- (MEG) or electroencephalography (EEG). One key drawback of the commonly used tests for stationarity of encephalographic time series is the fact that conclusions on stationarity are only indirectly inferred either from the Gaussianity (e.g. the Shapiro-Wilk test or Kolmogorov-Smirnov test) or the randomness of the time series and the absence of trend using very simple time-series models (e.g. the sign and trend tests by Bendat and Piersol). We present a novel approach to the analysis of the stationarity of MEG and EEG time series by applying modern statistical methods which were specifically developed in econometrics to verify the hypothesis that a time series is stationary. We report our findings of the application of three different tests of stationarity--the Kwiatkowski-Phillips-Schmidt-Schin (KPSS) test for trend or mean stationarity, the Phillips-Perron (PP) test for the presence of a unit root and the White test for homoscedasticity--on an illustrative set of MEG data. For five stimulation sessions, we found already for short epochs of duration of 250 and 500 ms that, although the majority of the studied epochs of single MEG trials were usually mean-stationary (KPSS test and PP test), they were classified as nonstationary due to their heteroscedasticity (White test). We also observed that the presence of external auditory stimulation did not significantly affect the findings regarding the stationarity of the data. We conclude that the combination of these tests allows a refined analysis of the stationarity of MEG and EEG time series.
Anti-Listeria starters: in vitro selection and production plant evaluation.
Raimondi, Stefano; Popovic, Mina; Amaretti, Alberto; Di Gioia, Diana; Rossi, Maddalena
2014-05-01
Anti-Listeria bacterial starters are highly demanded by the meat industry. Novel bioprotective anti-Listeria starters were searched among Lactobacillus species strains isolated from artisanal sausages. The screening confirmed that anti-Listeria activity is a strain-specific property and yielded only 1 strain (of 36) exhibiting a satisfactory level of inhibition, L. delbrueckii WC0286. This strain was compared with two commercial bioprotective starters, SafePro B-SF-43 and SafePro B-LC-20, in a model simulating in vitro the first step of the fermentation process. The presence of the bioprotective starters did not modify the pH in such a way that could affect the safety or organoleptic properties of the product. Both SafePro B-SF-43 and SafePro B-LC-20 effected an important reduction of Listeria counts (0.56 and 0.72 log CFU g(-1), respectively, in 72 h), while the anti-Listeria effect of L. delbrueckii WC0286 was minor (0.15 log CFU g(-1)). These results discouraged the utilization of L. delbrueckii WC0286 for a challenge test in a pilot salami production, in favor of the best-performing bioprotective starter, SafePro B-LC-20. The test confirmed that SafePro B-LC-20 did not alter the acidification trend of sausages and was capable of inhibiting Listeria, which decreased by 1.21 log CFU g(-1). This information is relevant to address research activity toward the development of new bioprotective starters. The data herein presented demonstrate that the efficacy in Listeria control of potentially bioprotective bacterial starters requires further validation in real meat matrixes, possibly by using in vitro meat fermentation experiments to narrow down the list of candidates before pilot scale challenge tests.
SU-F-I-15: Evaluation of a New MR-Compatible Respiratory Motion Device at 3T
DOE Office of Scientific and Technical Information (OSTI.GOV)
Soliman, A; Sunnybrook Health Sciences Centre, Toronto, ON; Chugh, B
Purpose: Recent advances in MRI-guided radiotherapy has inspired the development of MRI-compatible motion devices that simulate patient periodic motion in the scanner, particularly respiratory motion. Most commercial devices rely on non MR-safe ferromagnetic stepper motors which are not practical for regular QA testing. This work evaluates the motion performance of a new fully MRI compatible respiratory motion device at 3T. Methods: The QUASAR™ MRI-compatible respiratory motion phantom has been recently developed by Modus QA Inc., London, ON, Canada. The prototype is constructed from diamagnetic materials with linear motion generated using MRI-compatible piezoelectric motors that can be safely inserted in themore » scanner bore. The tumor was represented by a fillable sphere and is attached to the linear motion generator. The spherical tumor-representative and its surroundings were filled with different concentrations of MnCl2 to produce realistic relaxation times. The motion was generated along the longitudinal (H/F) axis of the bore using sinusoidal reference waveform (amplitude = 15 mm, frequency 0.25 Hz). Imaging was then performed on 3T Philips Achieva using a 32-channel cardiac coil. Fast 2D spoiled gradient-echo was used with a spatial resolution of 1.8 × 1.8 mm{sup 2} and slice thickness of 4 mm. The motion waveform was then measured on the resultant image series by tracking the centroid of the sphere through the time series. This image-derived measured motion was compared to the software-generated reference waveform. Results: No visible distortions from the device were observed on the images. Excellent agreement between the measured and the reference waveforms were obtained. Negligible motion was observed in the lateral (R/L) direction. Conclusion: Our investigation demonstrates that this piezo-electric motor design is effective at simulating periodic motion and is a potential candidate for MRI-radiotherapy respiratory motion simulation. Future work should focus on evaluating non-sinusoidal waveforms, fast 3D pulse sequences, and perform dosimetric QA.« less
Paratransit Vehicle Test and Evaluation : Volume 2. Acceleration and Interior Measurement Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume II) presents the test procedure and results of the acceleration and interior measurement test series. The tests determined the acceleratio...
Safe Driving Climate among Friends (SDCaF): A new scale.
Guggenheim, Noga; Taubman-Ben-Ari, Orit
2018-01-01
Reckless driving among young people, especially young men, is a major cause of injury and fatalities the world over. Like other aspects of this age group, young drivers' driving behaviors and norms are influenced by the accepted social discourse of their peers. Yet despite extensive existing knowledge on young drivers, very few studies have dealt specifically with their characteristic friendship relations. This lacuna in the literature may reflect the absence of specific research tools for examining driving with friends. To fill this gap, we conducted a series of studies with 706 young drivers (aged 17-24) of both sexes aimed at developing and validating a multidimensional scale designed to examine the effect of the social relations of adolescents and young adults on their driving. Entitled Safe Driving Climate among Friends (SDCaF), the final scale consists of 19 items, which tap four dimensions of driving with friends: friends' pressure; social costs of driving with friends; communication with friends about driving; and shared commitment to safe driving. The validity of the scale was established by examining associations between its four dimensions and various variables of personality, friendship, and driving. The findings indicate good reliability and validity, with the three variables of resistance to peer influence, self-disclosure, and personal responsibility for safe driving yielding positive associations with the SDCaF dimensions communication and shared commitment to safe driving, and negative associations with the dimensions friends' pressure and social costs. General tendency to respond to social pressure was positively associated with the dimensions of friends' pressure and social costs, and negatively associated with shared commitment to safe driving. Gender differences were also found, with men scoring higher than women on friends' pressure, and lower than women on shared commitment to safe driving. The SDCaF can serve as a research tool, as well as a diagnostic instrument for detecting susceptibility to reckless driving among young drivers, thereby aiding in the design of targeted educational and intervention programs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Edmondson, M C; Sherry, K R; Afolayan, J; Armitage, A R; Skyrme, A D
2011-03-01
Treatment for metatarsal head avascular necrosis is largely conservative. For severe or refractory cases there are various surgical options. We have performed a 'modified Weil's osteotomy' of the distal metatarsal in order to manage this problem. We present the largest case series, to our knowledge, with 17 such cases. The patients were scored pre- and post-operatively using the AOFAS Forefoot scoring system. We found that this procedure provided a mean score improvement of 36 points, with a complication rate of 5.9%. We would advocate this modified osteotomy as an effective, reliable and safe treatment option. Copyright © 2009 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Use of coblation in resection of juvenile nasopharyngeal angiofibroma.
Cannon, Daniel E; Poetker, David M; Loehrl, Todd A; Chun, Robert H
2013-06-01
We present a series of 4 patients with juvenile nasopharyngeal angiofibroma (JNA) who underwent Coblation-assisted endoscopic resection after preoperative embolization, and discuss the use and advantages of endoscopic Coblation-assisted resection of JNA. Our limited case series suggests that Coblation may be used in the resection of JNA after embolization in a relatively safe, efficient, and effective manner. Coblation allows for decreased bleeding, less need for instrumentation, and improved visualization. There are limited published data in the literature to date on the use of Coblation in endoscopic JNA resection. We describe its use in a more extensive tumor than those previously reported. Further studies are needed to fully define the safety and utility of Coblation technology for this application.
Cervical Chondrocutaneous Branchial Remnants.
Klockars, Tuomas; Kajosaari, Lauri
2017-03-01
Cervical chondrocutaneous branchial remnants are rare malformations usually found in the lower neck. As high as 76% of patients have been reported to have associated anomalies. We review the literature and report a case series of seven patients with cervical cartilaginous remnants. A retrospective case series of seven patients identified from the electronic hospital records. Seven patients with cervical chondrocutaneous branchial remnants were identified (six boys and one girl). Only one of the patients had associated anomalies. A review of the literature revealed no evidence for sinuses or cysts related to cervical chondrocutaneous branchial remnants. Operative treatment can be postponed to a suitable and safe age. There is marked variation in the reported prevalence of associated anomalies, ranging from 11% to 76%.
Solar Photovoltaic DC Systems: Basics and Safety: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNutt, Peter F; Sekulic, William R; Dreifuerst, Gary
Solar Photovoltaic (PV) systems are common and growing with 42.4 GW installed capacity in U.S. (almost 15 GW added in 2016). This paper will help electrical workers, and emergency responders understand the basic operating principles and hazards of PV DC arrays. We briefly discuss the following aspects of solar photovoltaic (PV) DC systems: the effects of solar radiation and temperature on output power; PV module testing standards; common system configurations; a simple PV array sizing example; NEC guidelines and other safety features; DC array commissioning, periodic maintenance and testing; arc-flash hazard potential; how electrical workers and emergency responders can andmore » do work safely around PV arrays; do moonlight and artificial lighting pose a real danger; typical safe operating procedures; and other potential DC-system hazards to be aware of. We also present some statistics on PV DC array electrical incidents and injuries. Safe PV array operation is possible with a good understanding of PV DC arrays basics and having good safe operating procedures in place.« less
Access to safe water in rural Artibonite, Haiti 16 months after the onset of the cholera epidemic.
Patrick, Molly; Berendes, David; Murphy, Jennifer; Bertrand, Fabienne; Husain, Farah; Handzel, Thomas
2013-10-01
Haiti has the lowest improved water and sanitation coverage in the Western Hemisphere and is suffering from the largest cholera epidemic on record. In May of 2012, an assessment was conducted in rural areas of the Artibonite Department to describe the type and quality of water sources and determine knowledge, access, and use of household water treatment products to inform future programs. It was conducted after emergency response was scaled back but before longer-term water, sanitation, and hygiene activities were initiated. The household survey and source water quality analysis documented low access to safe water, with only 42.3% of households using an improved drinking water source. One-half (50.9%) of the improved water sources tested positive for Escherichia coli. Of households with water to test, 12.7% had positive chlorine residual. The assessment reinforces the identified need for major investments in safe water and sanitation infrastructure and the importance of household water treatment to improve access to safe water in the near term.
Paratransit Vehicle Test and Evaluation : Volume 4. Fuel Economy Tests.
DOT National Transportation Integrated Search
1978-06-01
A series of tests and evaluations of two prototype vehicles for paratransit were conducted. This volume (Volume IV) presents the test procedures and results of the fuel economy tests. The test series determined the fuel economy of the vehicles as the...
Ethylene oxide sterilisation--is it safe?
Gillespie, E H; Jackson, J M; Owen, G R
1979-01-01
Tests show that ethylene oxide penetrates and can sterilise long narrow tubes in a hospital ethylene oxide steriliser. Residual ethylene oxide levels in plastic tubing after sterilisation have been estimated. Although initially the levels were very high, storage for four days at room temperature reduced them to a safe level. If adequate controls of the sterilising process and storage are carried out, sterilisation by ethylene oxide is considered to be safe for new plastics and clean equipment. Images Figure PMID:512032
Kakuda, Wataru; Abo, Masahiro; Uruma, Go; Kaito, Nobuyoshi; Watanabe, Motoi
2010-01-01
To examine the safety and feasibility of therapeutic application of low-frequency repetitive transcranial magnetic stimulation (rTMS) combined with language therapy for post-stroke patients with sensory-dominant aphasia. Two post-stroke Japanese patients with sensory-dominant aphasia were studied. In both patients, 10 sessions of 20-minute low-frequency rTMS with 1 Hz to the Wernicke's area were provided throughout 6-day hospitalization, followed by weekly outpatient rTMS treatment for 3 months. The language therapy was also provided through the period of in- and out-patient treatment. Language function was evaluated using the Token test and the Standard Language Test of Aphasia (SLTA) at the start and end of the in-patient treatment and the end of the outpatient treatment. The therapeutic protocol was well tolerated throughout the in- and out-patient treatments, without any adverse effects. The scores of the Token test and certain sub-categories of SLTA increased in both patients after the in-patient rTMS treatment. Persistent improvement of the score was noted over the 3-month post-discharge period. The proposed protocol of long-term application of low-frequency rTMS to the Wernicke's area and language therapy is considered a safe and feasible therapeutic approach for post-stroke patients with sensory-dominant aphasia.
Multi-Element Unstructured Analyses of Complex Valve Systems
NASA Technical Reports Server (NTRS)
Sulyma, Peter (Technical Monitor); Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy
2004-01-01
The safe and reliable operation of high pressure test stands for rocket engine and component testing places an increased emphasis on the performance of control valves and flow metering devices. In this paper, we will present a series of high fidelity computational analyses of systems ranging from cryogenic control valves and pressure regulator systems to cavitating venturis that are used to support rocket engine and component testing at NASA Stennis Space Center. A generalized multi-element framework with sub-models for grid adaption, grid movement and multi-phase flow dynamics has been used to carry out the simulations. Such a framework provides the flexibility of resolving the structural and functional complexities that are typically associated with valve-based high pressure feed systems and have been difficult to deal with traditional CFD methods. Our simulations revealed a rich variety of flow phenomena such as secondary flow patterns, hydrodynamic instabilities, fluctuating vapor pockets etc. In the paper, we will discuss performance losses related to cryogenic control valves, and provide insight into the physics of the dominant multi-phase fluid transport phenomena that are responsible for the choking like behavior in cryogenic control elements. Additionally, we will provide detailed analyses of the modal instability that is observed in the operation of the dome pressure regulator valve. Such instabilities are usually not localized and manifest themselves as a system wide phenomena leading to an undesirable chatter at high flow conditions.
Ribnicky, David M; Poulev, Alexander; O'Neal, Joseph; Wnorowski, Gary; Malek, Dolores E; Jäger, Ralf; Raskin, Ilya
2004-04-01
TARRALIN is an ethanolic extract of Artemisia dracunculus (Russian tarragon), a common medicinal and culinary herb with centuries of use. Artemisia dracunculus is a close relative of the French or cooking tarragon and contains components common to many herbs that are routinely consumed without reported adverse effects. Since safety information of Artemisia dracunculus and its extract is limited to historical use, TARRALIN was examined in a series of toxicological studies. Complete Ames analysis did not reveal any mutagenic activity either with or without metabolic activation. TARRALIN was tested in an acute limit test at 5000 mg/kg with no signs of toxicity noted. In a 14 day repeated dose oral toxicity study, rats appeared to well tolerate 1000 mg/kg/day. Subsequently, TARRALIN was tested in an oral subchronic 90-day toxicity study (rat) at doses of 10, 100 and 1000 mg/kg/day. No noteworthy signs of toxicity were noted in feeding or body weight, functional observational battery or motor activity. Gross necropsy and clinical chemistry did not reveal any effects on organ mass or blood chemistry and microscopic examinations found no lesions associated with treatment. Therefore, TARRALIN appears to be safe and non-toxic in these studies and a no-observed adverse effect level in rats is established at 1000 mg/kg/day.
A personal airbag system for the Orion Crew Exploration Vehicle
NASA Astrophysics Data System (ADS)
Do, Sydney; de Weck, Olivier
2012-12-01
Airbag-based methods for crew impact attenuation have been highlighted as a potential simple, lightweight means of enabling safe land-landings for the Orion Crew Exploration Vehicle, and the next generation of ballistic shaped spacecraft. To investigate the feasibility of this concept during a nominal 7.62 m/s Orion landing, a full-scale personal airbag system 24% lighter than the Orion baseline has been developed, and subjected to 38 drop tests on land. Through this effort, the system has demonstrated the ability to maintain the risk of injury to an occupant during a 7.85 m/s, 0° impact angle land-landing to within the NASA specified limit of 0.5%. In accomplishing this, the personal airbag system concept has been proven to be feasible. Moreover, the obtained test results suggest that by implementing anti-bottoming airbags to prevent direct contact between the system and the landing surface, the system performance during landings with 0° impact angles can be further improved, by at least a factor of two. Additionally, a series of drop tests from the nominal Orion impact angle of 30° indicated that severe injury risk levels would be sustained beyond impact velocities of 5 m/s. This is a result of the differential stroking of the airbags within the system causing a shearing effect between the occupant seat structure and the spacecraft floor, removing significant stroke from the airbags.
Validation and verification of the laser range safety tool (LRST)
NASA Astrophysics Data System (ADS)
Kennedy, Paul K.; Keppler, Kenneth S.; Thomas, Robert J.; Polhamus, Garrett D.; Smith, Peter A.; Trevino, Javier O.; Seaman, Daniel V.; Gallaway, Robert A.; Crockett, Gregg A.
2003-06-01
The U.S. Dept. of Defense (DOD) is currently developing and testing a number of High Energy Laser (HEL) weapons systems. DOD range safety officers now face the challenge of designing safe methods of testing HEL's on DOD ranges. In particular, safety officers need to ensure that diffuse and specular reflections from HEL system targets, as well as direct beam paths, are contained within DOD boundaries. If both the laser source and the target are moving, as they are for the Airborne Laser (ABL), a complex series of calculations is required and manual calculations are impractical. Over the past 5 years, the Optical Radiation Branch of the Air Force Research Laboratory (AFRL/HEDO), the ABL System Program Office, Logicon-RDA, and Northrup-Grumman, have worked together to develop a computer model called teh Laser Range Safety Tool (LRST), specifically designed for HEL reflection hazard analyses. The code, which is still under development, is currently tailored to support the ABL program. AFRL/HEDO has led an LRST Validation and Verification (V&V) effort since 1998, in order to determine if code predictions are accurate. This paper summarizes LRST V&V efforts to date including: i) comparison of code results with laboratory measurements of reflected laser energy and with reflection measurements made during actual HEL field tests, and ii) validation of LRST's hazard zone computations.
Automated Testing Experience of the Linear Aerospike SR-71 Experiment (LASRE) Controller
NASA Technical Reports Server (NTRS)
Larson, Richard R.
1999-01-01
System controllers must be fail-safe, low cost, flexible to software changes, able to output health and status words, and permit rapid retest qualification. The system controller designed and tested for the aerospike engine program was an attempt to meet these requirements. This paper describes (1) the aerospike controller design, (2) the automated simulation testing techniques, and (3) the real time monitoring data visualization structure. Controller cost was minimized by design of a single-string system that used an off-the-shelf 486 central processing unit (CPU). A linked-list architecture, with states (nodes) defined in a user-friendly state table, accomplished software changes to the controller. Proven to be fail-safe, this system reported the abort cause and automatically reverted to a safe condition for any first failure. A real time simulation and test system automated the software checkout and retest requirements. A program requirement to decode all abort causes in real time during all ground and flight tests assured the safety of flight decisions and the proper execution of mission rules. The design also included health and status words, and provided a real time analysis interpretation for all health and status data.
Flight Testing ALHAT Precision Landing Technologies Integrated Onboard the Morpheus Rocket Vehicle
NASA Technical Reports Server (NTRS)
Carson, John M. III; Robertson, Edward A.; Trawny, Nikolas; Amzajerdian, Farzin
2015-01-01
A suite of prototype sensors, software, and avionics developed within the NASA Autonomous precision Landing and Hazard Avoidance Technology (ALHAT) project were terrestrially demonstrated onboard the NASA Morpheus rocket-propelled Vertical Testbed (VTB) in 2014. The sensors included a LIDAR-based Hazard Detection System (HDS), a Navigation Doppler LIDAR (NDL) velocimeter, and a long-range Laser Altimeter (LAlt) that enable autonomous and safe precision landing of robotic or human vehicles on solid solar system bodies under varying terrain lighting conditions. The flight test campaign with the Morpheus vehicle involved a detailed integration and functional verification process, followed by tether testing and six successful free flights, including one night flight. The ALHAT sensor measurements were integrated into a common navigation solution through a specialized ALHAT Navigation filter that was employed in closed-loop flight testing within the Morpheus Guidance, Navigation and Control (GN&C) subsystem. Flight testing on Morpheus utilized ALHAT for safe landing site identification and ranking, followed by precise surface-relative navigation to the selected landing site. The successful autonomous, closed-loop flight demonstrations of the prototype ALHAT system have laid the foundation for the infusion of safe, precision landing capabilities into future planetary exploration missions.
EJ SMALL GRANT: SAFE DRINKING WATER FOR LOW INCOME COMMUNITIES
Legal Aid Services of Oregon (LASO) has determined that both EPA Region 10 and the Oregon Health Division have identified regulatory defects in the Safe Drinking Water Act with respect to migrant farmworker drinking water sources. Lack of mandatory testing, lack of enforcement a...
X-Ray Exam: Neck (For Parents)
... Staying Safe Videos for Educators Search English Español X-Ray Exam: Neck KidsHealth / For Parents / X-Ray Exam: Neck What's in this article? What ... español Radiografía: cuello What It Is A neck X-ray is a safe and painless test that ...
Endoscopically placed nitinol stents for pediatric tracheal obstruction.
Prasad, Mukesh; Bent, John P; Ward, Robert F; April, Max M
2002-11-11
To provide preliminary clinical data regarding endoscopically placed nitinol stents for children with tracheal obstruction as a temporizing measure to allow for trach tube decannulation while awaiting growth to allow for tracheal resection. This case series describes the experiences of two children (ages 5 and 15) who were dependent upon tracheotomy because of acquired tracheal obstruction. Both patients had combined tracheomalacia and tracheal stenosis. After failing tracheoplasty with rib graft augmentation both patients suffered from extensive tracheal disease, which was too long to allow for immediate tracheal resection. Endoscopic placement of nitinol stents in the obstructed tracheal segment using fluoroscopic guidance. All tracheotomy tubes were removed immediately after successful stent deployment with the patient still under general anesthesia. Four stents were placed in total. The first patient's initial stent was too narrow and was, therefore, removed and replaced at a later date with a larger diameter stent. The second patient experienced distal migration of his initial stent requiring stent removal and replacement at a later date. Both patients remain successfully decannulated (follow-up, 25 and 26 months) and are currently living more normal lives as they grow and await tracheal resection. Preliminary use of nitinol stents for pediatric tracheal obstruction has enabled successful decannulation in two children with complicated airways. Our results with this series of patients suggest that nitinol stents can be safely used in children as a temporizing measure until tracheal resection can be safely performed. With this approach children can live free from the hassles of trach care, social isolation and peer ridicule. Limited pediatric experience exists in the literature about nitinol stents. Thus, our experience with stent selection and placement will help others avoid problems encountered in this initial series. Copyright 2002 Elsevier Science Ireland Ltd.
M-52 spray booth qualification test
NASA Technical Reports Server (NTRS)
1990-01-01
The procedures, performance, and results obtained from the M-52 spray booth qualification test are documented. The test was conducted at Thiokol Corporation, Space Operations, M-52 Inert Parts Preparation facility. The purpose of this testing sequence was to ensure the spray booth would produce flight qualified hardware. The testing sequence was conducted in two series. The first series was conducted under CTP-0142, Revision 1. The second series was conducted in accordance with CTP-0142, Revision 2. The test sequence started with CTP-0142, Revision 1. The series consisted of the contamination removal test and the performance test. The contamination removal test was used to assess the Teflon level in the spray booth. The performance test consisted of painting and Chemloking a forward dome inside the spray booth per flight procedures. During the performance test, two sets of witness panels (case/insulation and steel/epoxy/steel) were prepared and pull tested. The CTP-0142, Revision 2, series of testing consisted of re-testing the steel/epoxy/steel witness panels. The pull tests analysis indicates the results of the tensile tests were comparable to the systems tunnel witness panel database. The exposed panel set and the control panel set average tensile values were above the 1-basis lower limits established on the systems tunnel witness panel database. It is recommended that the M-52 spray booth be qualified for producing flight hardware.
ERIC Educational Resources Information Center
Seif, Hinda
2009-01-01
As demographics shift and immigration is a hotly contested area of US civic life, the civic preparation and participation of Latin American immigrant youth is becoming increasingly important. The author examines the growing literature on this topic, inquiring into the political and demographic changes that have stimulated this area of inquiry, the…
ERIC Educational Resources Information Center
Lewis-Palmer, Teri; Flannery, Brigid; Sugai, George; Eber, Lucille
This monograph describes the unique features of secondary schools and the application of a systems approach to school discipline at the secondary level. The use of effective behavior support (EBS) designed to increase the capacity of schools to educate all students, especially students with behavioral challenges, is highlighted. Critical features…
Safe2Tell® : an anonymous, 24/7 reporting system for preventing school violence.
Payne, Susan R T; Elliott, Delbert S
2011-01-01
There is widespread agreement that many school shootings could be prevented if authorities were informed that a student was planning or preparing to carry out an attack. A universal problem is that young people are highly reluctant to report on their peers. This code of silence represents a major barrier to prevention efforts. In response to the Columbine shooting, the state of Colorado established the Safe2Tell® anonymous, 24/7 reporting system for receiving and forwarding threats of violence, bullying, and other concerns. This article describes how the program has grown to the point that it now receives more than 100 calls per month. A series of case examples illustrates its success in responding to threatening situations, including twenty-eight potential school attacks. Copyright © 2011 Wiley Periodicals, Inc., A Wiley Company.
Exploratory Development on an Electronic Safing and Arming Device for Ordnance Fuzing
1983-02-01
to the bridges. Two units were subjected to MIL-STD-331, Test 101, Jolt. The EBMs were placed in the S & A cavity of an M739 fuze body for this test...of the program was to explore a concept for a safe, reliable, general purpose, low cost, electronic, A ’ zsafing and arming ( S & A ) system for use in...breadboard model hardware of the electronic S & A device. The electronic S & A devicu consists of an explosive barrier moduls (EBM) explosive train
Laser Safety and Hazardous Analysis for the ARES (Big Sky) Laser System
DOE Office of Scientific and Technical Information (OSTI.GOV)
AUGUSTONI, ARNOLD L.
A laser safety and hazard analysis was performed for the ARES laser system based on the 2000 version of the American National Standards Institute's (ANSI) Standard Z136.1,for Safe Use of Lasers and the 2000 version of the ANSI Standard Z136.6, for Safe Use of Lasers Outdoors. The ARES laser system is a Van/Truck based mobile platform, which is used to perform laser interaction experiments and tests at various national test sites.
Chung, Rick
2012-06-01
Patient empowerment has increased the demand for direct to consumer (DTC) laboratory testing. Multiple professional societies and advocacy groups have raised concerns over how DTC laboratory testing is being offered to consumers without proper physician oversight. Physician telehealth services can properly oversee DTC laboratory testing in a safe and medically sound manner. Using telehealth protocols and standards established by professional health organizations and state regulators, physician telehealth oversight in DTC laboratory test ordering can be effective to increase patient access to healthcare services. With proper physician oversight in test interpretation, post-test counseling, and information collaboration, DTC laboratory testing can remain a reliable and convenient option for consumers. Working within the channel of distribution of most DTC laboratory testing, physician telehealth services can properly oversee DTC laboratory testing in a safe and medically sound manner to ensure that proper test interpretation, counseling, and information collaboration are achieved. Physician telehealth services can properly oversee DTC laboratory testing to ensure that proper test interpretation, counseling, and information collaboration are achieved.
Full-Scale Accident Testing in Support of Used Nuclear Fuel Transportation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durbin, Samuel G.; Lindgren, Eric R.; Rechard, Rob P.
2014-09-01
The safe transport of spent nuclear fuel and high-level radioactive waste is an important aspect of the waste management system of the United States. The Nuclear Regulatory Commission (NRC) currently certifies spent nuclear fuel rail cask designs based primarily on numerical modeling of hypothetical accident conditions augmented with some small scale testing. However, NRC initiated a Package Performance Study (PPS) in 2001 to examine the response of full-scale rail casks in extreme transportation accidents. The objectives of PPS were to demonstrate the safety of transportation casks and to provide high-fidelity data for validating the modeling. Although work on the PPSmore » eventually stopped, the Blue Ribbon Commission on America’s Nuclear Future recommended in 2012 that the test plans be re-examined. This recommendation was in recognition of substantial public feedback calling for a full-scale severe accident test of a rail cask to verify evaluations by NRC, which find that risk from the transport of spent fuel in certified casks is extremely low. This report, which serves as the re-assessment, provides a summary of the history of the PPS planning, identifies the objectives and technical issues that drove the scope of the PPS, and presents a possible path for moving forward in planning to conduct a full-scale cask test. Because full-scale testing is expensive, the value of such testing on public perceptions and public acceptance is important. Consequently, the path forward starts with a public perception component followed by two additional components: accident simulation and first responder training. The proposed path forward presents a series of study options with several points where the package performance study could be redirected if warranted.« less
NASA Technical Reports Server (NTRS)
Keppenne, Christian L.; Rienecker, Michele M.; Kovach, Robin M.; Vernieres, Guillaume; Koster, Randal D. (Editor)
2014-01-01
An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory. SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.
NASA Technical Reports Server (NTRS)
Keppenne, Christian L.; Rienecker, Michele; Kovach, Robin M.; Vernieres, Guillaume
2014-01-01
An attractive property of ensemble data assimilation methods is that they provide flow dependent background error covariance estimates which can be used to update fields of observed variables as well as fields of unobserved model variables. Two methods to estimate background error covariances are introduced which share the above property with ensemble data assimilation methods but do not involve the integration of multiple model trajectories. Instead, all the necessary covariance information is obtained from a single model integration. The Space Adaptive Forecast error Estimation (SAFE) algorithm estimates error covariances from the spatial distribution of model variables within a single state vector. The Flow Adaptive error Statistics from a Time series (FAST) method constructs an ensemble sampled from a moving window along a model trajectory.SAFE and FAST are applied to the assimilation of Argo temperature profiles into version 4.1 of the Modular Ocean Model (MOM4.1) coupled to the GEOS-5 atmospheric model and to the CICE sea ice model. The results are validated against unassimilated Argo salinity data. They show that SAFE and FAST are competitive with the ensemble optimal interpolation (EnOI) used by the Global Modeling and Assimilation Office (GMAO) to produce its ocean analysis. Because of their reduced cost, SAFE and FAST hold promise for high-resolution data assimilation applications.
NASA Technical Reports Server (NTRS)
Kassel, P. C., Jr.
1978-01-01
A fail safe light activated switch was used as an emergency control link at the Langley Vortex Research Facility. In this facility aircraft models were towed through a still air test chamber by a gasoline powered vehicle which was launched from one end of a 427-meter track and attained velocities to 31 m/sec in the test chamber. A 5 mW HeNe laser with a mechanical copper provided a connecting link with the moving tow vehicle on which a silicon photodiode receiver with a specially designed amplifier provided a fail safe switching action. This system provided an emergency means of stopping the vehicle by turning off the laser to interrupt the power to the vehicle ignition and brake release systems.
NASA Technical Reports Server (NTRS)
Freeman, John L.; Steele, Marianne K.; Sun, Gwo-Shing; Heathcote, David; Reinsch, S.; DeSimone, Julia C.; Myers, Zachary A.
2014-01-01
The aim of our ground testing was to demonstrate the capability of safely putting specific model organisms into dehydrated stasis, and to later rehydrate and successfully grow them inside flight proven ARC EMCS seedling cassettes. The ARC EMCS seedling cassettes were originally developed to support seedling growth during space flight. The seeds are attached to a solid substrate, launched dry, and then rehydrated in a small volume of media on orbit to initiate the experiment. We hypothesized that the same seedling cassettes should be capable of acting as culture chambers for a wide range of organisms with minimal or no modification. The ability to safely preserve live organisms in a dehydrated state allows for on orbit experiments to be conducted at the best time for crew operations and more importantly provides a tightly controlled physiologically relevant growth experiment with specific environmental parameters. Thus, we performed a series of ground tests that involved growing the organisms, preparing them for dehydration on gridded Polyether Sulfone (PES) membranes, dry storage at ambient temperatures for varying periods of time, followed by rehydration. Inside the culture cassettes, the PES membranes were mounted above blotters containing dehydrated growth media. These were mounted on stainless steel bases and sealed with plastic covers that have permeable membrane covered ports for gas exchange. The results showed we were able to demonstrate acceptable normal growth of C.elegans (nematodes), E.coli (bacteria), S.cerevisiae (yeast), Polytrichum (moss) spores and protonemata, C.thalictroides (fern), D.discoideum (amoeba), and H.dujardini (tardigrades). All organisms showed acceptable growth and rehydration in both petri dishes and culture cassettes initially, and after various time lengths of dehydration. At the end of on orbit ISS European Modular Cultivation System experiments the cassettes could be frozen at ultra-low temperatures, refrigerated, or chemically preserved before being returned to Earth for analyses. Our results suggest that with protocol modifications and future verification testing we can utilize the versatile EMCS to conduct tightly controlled experiments inside our culture cassettes for a wide variety of organisms. These physiological experiments would be designed to answer questions at the molecular level about the specific stress responses of space flight.
Safe lithium-ion battery with ionic liquid-based electrolyte for hybrid electric vehicles
NASA Astrophysics Data System (ADS)
Damen, Libero; Lazzari, Mariachiara; Mastragostino, Marina
2011-10-01
A lithium-ion battery featuring graphite anode, LiFePO4-C cathode and an innovative, safe, ionic liquid-based electrolyte, was assembled and characterized in terms of specific energy and power after the USABC-DOE protocol for power-assist hybrid electric vehicle (HEV) application. The test results show that the battery surpasses the energy and power goals stated by USABC-DOE and, hence, this safe lithium-ion battery should be suitable for application in the evolving HEV market.
40 CFR 792.43 - Test system care facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... waste and refuse or for safe sanitary storage of waste before removal from the testing facility... conditions (e.g., temperature, humidity, photoperiod) as specified in the protocol. (f) For marine test...
Burby, Joshua W.; Lacker, Daniel
2016-01-01
Systems as diverse as the interacting species in a community, alleles at a genetic locus, and companies in a market are characterized by competition (over resources, space, capital, etc) and adaptation. Neutral theory, built around the hypothesis that individual performance is independent of group membership, has found utility across the disciplines of ecology, population genetics, and economics, both because of the success of the neutral hypothesis in predicting system properties and because deviations from these predictions provide information about the underlying dynamics. However, most tests of neutrality are weak, based on static system properties such as species-abundance distributions or the number of singletons in a sample. Time-series data provide a window onto a system’s dynamics, and should furnish tests of the neutral hypothesis that are more powerful to detect deviations from neutrality and more informative about to the type of competitive asymmetry that drives the deviation. Here, we present a neutrality test for time-series data. We apply this test to several microbial time-series and financial time-series and find that most of these systems are not neutral. Our test isolates the covariance structure of neutral competition, thus facilitating further exploration of the nature of asymmetry in the covariance structure of competitive systems. Much like neutrality tests from population genetics that use relative abundance distributions have enabled researchers to scan entire genomes for genes under selection, we anticipate our time-series test will be useful for quick significance tests of neutrality across a range of ecological, economic, and sociological systems for which time-series data are available. Future work can use our test to categorize and compare the dynamic fingerprints of particular competitive asymmetries (frequency dependence, volatility smiles, etc) to improve forecasting and management of complex adaptive systems. PMID:27689714
Silvestre, Maria Asuncion A; Dans, Leonila F; Dans, Antonio L
2011-03-01
Evidence on the effectiveness of health screening strategies may be direct (i.e., studies on screening vs. no screening) or indirect (i.e., studies that separately evaluate the screening test[s], the confirmatory test, or the treatment). Critical trade-offs in the balance between harm and benefit for many screening strategies mandate that advocates of health screening adhere to the ethical precepts of nonmaleficence, autonomy, confidentiality, and equity. In our first article, we pointed out five prerequisites to justifying a health screening program: (1) the burden of illness should be high, (2) the screening and confirmatory tests should be accurate, (3) early treatment (or prevention) must be more effective than late treatment, (4) the tests and the treatment(s) must be safe, and (5) the cost of the screening strategy must be commensurate with the potential benefit. As can be gleaned from these criteria, recommendations on screening must be tailored to specific populations. Recommendations in one country, no matter how authoritative, cannot be generalized to apply to all other countries. Although accuracy, effectiveness, and safety data may be global (criteria 2-4), burden of illness and efficiency (criteria 1 and 5) will always vary from country to country. Rather than review various national guidelines, in this last article of our two-part series, we present evidence summaries to illustrate health screening. Our examples were selected to address special issues related to four situations-screening for cancer, risk factors for disease, genetic disorders, and infectious diseases. Copyright © 2011 Elsevier Inc. All rights reserved.
National evaluation of the SafeTrip-21 initiative : final report real time intersection delay.
DOT National Transportation Integrated Search
2010-09-17
Through the U.S. Department of Transportations (USDOT) SafeTrip-21 initiative, the USDOT is testing a variety of : technologies in a number of locations in California as well as along the I-95 corridor on the east coast. As part of this Federal : ...
SAFETY GUIDES FOR YOU--IN THE PRIMARY GRADES.
ERIC Educational Resources Information Center
WALKER, LUVERNE CRABTREE
THIS SAFETY INSTRUCTIONAL GUIDE FOR PRIMARY-GRADE TEACHERS PRESENTS NINE DIFFERENT SAFETY UNITS, INCLUDING TRAFFIC SAFETY, PLAYTIME SAFETY, SAFE EATING AND DRINKING HABITS, SAFE CLOTHING, HOME SAFETY, ANIMAL SAFETY, CIVIL DEFENSE SECURITY, AND TESTING SAFETY PRACTICES. EACH UNIT STRESSES THE REASONS FOR ACCENTING SAFETY, WHAT TO KNOW AND DO, AND…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-09
... sunlamp products are mechanically safe to prevent user injury. Mechanical safety testing, such as cyclic... off) are in proper working order. This requirement would mitigate increased skin cancer risk from... that sunlamp products are electrically safe and electromagnetically compatible in their intended use...
DOT National Transportation Integrated Search
2010-11-24
Through the U.S. Department of Transportations (USDOT) SafeTrip-21 initiative, the USDOT is testing a variety of technologies in a number of locations in California as well as along the I-95 corridor on the east coast. This document presents the e...
Safe and effective nursing shift handover with NURSEPASS: An interrupted time series.
Smeulers, Marian; Dolman, Christine D; Atema, Danielle; van Dieren, Susan; Maaskant, Jolanda M; Vermeulen, Hester
2016-11-01
Implementation of a locally developed evidence based nursing shift handover blueprint with a bedside-safety-check to determine the effect size on quality of handover. A mixed methods design with: (1) an interrupted time series analysis to determine the effect on handover quality in six domains; (2) descriptive statistics to analyze the intercepted discrepancies by the bedside-safety-check; (3) evaluation sessions to gather experiences with the new handover process. We observed a continued trend of improvement in handover quality and a significant improvement in two domains of handover: organization/efficiency and contents. The bedside-safety-check successfully identified discrepancies on drains, intravenous medications, bandages or general condition and was highly appreciated. Use of the nursing shift handover blueprint showed promising results on effectiveness as well as on feasibility and acceptability. However, to enable long term measurement on effectiveness, evaluation with large scale interrupted times series or statistical process control is needed. Copyright © 2016 Elsevier Inc. All rights reserved.
Fraxel laser indications and long-term follow-up.
Tanzi, Elizabeth L; Wanitphakdeedecha, Rungsima; Alster, Tina S
2008-01-01
Fractional photothermolysis, based on creating spatially precise microscopic thermal wounds, is performed using a 1550-nm erbium fiber laser that targets water-containing tissue to effect the photocoagulation of narrow, sharply defined columns of skin known as microscopic thermal zones. According to the authors, Fraxel resurfacing has been shown to be both safe and effective for facial and nonfacial photodamage, atrophic acne scars, hypopigmented scars, and dyspigmentation. Because only a fraction of the skin is treated during a single session, a series (typically 3 to 6 treatments) of fractional resurfacing at 2- to 4-week intervals is required for the best clinical improvement. It is the authors' experience that a series of Fraxel treatments can achieve a similar clinical result for atrophic scars compared with traditional ablative laser skin resurfacing. However, the improvement seen after a series of Fraxel treatments for perioral laxity and rhytides often falls short of the impressive results that can be achieved with ablative laser skin resurfacing.
Mol, Frédérique Mathilde Ulrike; Roumen, Rudi M H
2018-04-01
Anterior Cutaneous Nerve Entrapment Syndrome (ACNES) is a debilitating neuropathic pain condition. A small portion of patients do not respond to any currently available treatment modalities. These patients, often young women, might benefit from targeted spinal cord stimulation of the dorsal root ganglion (DRG). This retrospective case series describes five ACNES patients who were referred from a Dutch dedicated tertiary referral center to collaborating sites with extensive experience in DRG stimulation to be implanted with a DRG Axium System (St. Jude/Abbott, IL, USA) in the period of 2013-2016. Numeric pain rating scores at routine 6- and 12-month follow-up visits were analyzed. Three patients experienced >50% pain reduction at 12 months follow-up. Four patients experienced device-related complications, such as lead dislocation, lead breakage, pain at the battery site, and overstimulation. This case series suggests DRG spinal cord stimulation can be safe and effective for some patients with persistent pain due to ACNES. © 2017 International Neuromodulation Society.
Clopidogrel (Plavix) desensitization: a case series.
Camara, Miguel G; Almeda, Francis Q
2005-08-01
Clopidogrel (Plavix) is a thiopyridine that inhibits the ADP-dependent pathway for platelet activation and has been shown in numerous trials to be effective for a wide variety of patients with cardiovascular disease, particularly those who have undergone coronary stent implantation and who present with acute coronary syndromes. Allergic rashes are one of the common side effects of clopidogrel, which leads to its discontinuation. Type I (Gell and Combs classification) allergic reactions to drugs may be amenable to drug desensitization, allowing safe and prolonged use of the drug. This case series describes a protocol for clopidogrel desensitization over an 8-hr period using 15 doubling doses of clopidogrel given by mouth to achieve a maintenance dose of 75 mg a day. This case series suggests that patients who have had type I drug allergy to clopidogrel may be rapidly desensitized using this protocol. Further studies enrolling a larger number of patients are indicated to confirm the safety and efficacy of this regimen.
Cangrelor use prior to left ventricular assist device surgery: a case series.
Washam, Jeffrey B; Yerokun, Babatunde; Patel, Chetan B; Welsby, Ian J; Milano, Carmelo A; DeVore, Adam D
2018-06-02
Bleeding frequently occurs in patients undergoing placement of a left ventricular assist device (LVAD). Clinical factors that have been identified as contributing to peri-procedural bleeding include LVAD implantation after an acute myocardial infarction and preoperative use of antiplatelet agents. In this report, we describe the use of cangrelor for preoperative antiplatelet bridging to LVAD in five post myocardial infarction patients with cardiogenic shock that had recently undergone percutaneous coronary intervention. During the cangrelor bridging period, no cases of thrombotic or major bleeding events occurred. During the first week following LVAD implantation, two patients experienced a major bleeding (each case required chest exploration for suspected hemorrhage). To our knowledge, this is the first series describing cangrelor use for antiplatelet bridging in patients undergoing LVAD implantation. While this series suggest cangrelor could possibly be a safe and effective antiplatelet bridging strategy, further research is needed to identify the optimal antithrombotic strategy in cardiogenic shock patients undergoing LVAD implantation who have recently undergoing percutaneous coronary intervention.
Test-retest reliability of the safe driving behavior measure for community-dwelling elderly drivers.
Song, Chiang-Soon; Lee, Joo-Hyun; Han, Sang-Woo
2016-06-01
[Purpose] The Safe Driving Behavior Measure (SDBM) is a self-report measurement tools that assesses the safe-driving behaviors of the elderly. The purpose of this study was to evaluate the test-retest reliability of the SDBM among community-dwelling elderly drivers. [Subjects and Methods] A total of sixty-one community-dwelling elderly were enrolled to investigate the reliability of the SDBM. The SDBM was assessed in two sessions that were conducted three days apart in a quiet and well-organized assessment room. That test-retest reliability of overall scores and three domain scores of the SDBM were statistically evaluated using intraclass correlation coefficients [ICC (2.1)]. Pearson correlation coefficients were used to quantify bivariate associations among the three domains of the SDBM. [Results] The SDBM demonstrated excellent rest-retest reliability for community-dwelling elderly drivers. The Cronbach alpha coefficients of the three domains of person-vehicle (0.979), person-environment (0.944), and person-vehicle-environment (0.971) of the SDBM indicate high internal consistency. [Conclusion] The results of this study suggest that the SDBM is a reliable measure for evaluating the safe- driving of automobiles by community-dwelling elderly, and is adequate for detecting changes in scores in clinical settings.
Ladner, Travis R; He, Lucy; Lakomkin, Nikita; Davis, Brandon J; Cheng, Joseph S; Devin, Clinton J; Mocco, J
2016-02-01
Intraoperative bleeding is a significant risk in surgery for highly vascular spinal tumors, but preoperative embolization can safely decrease intraoperative blood loss in extrinsic spine tumors. Onyx, widely used for cerebrovascular embolization, has been increasingly used as an embolic agent for preoperative spinal tumor embolization. The Scepter catheter, a dual-lumen balloon catheter, may improve tumor parenchymal penetration without the danger and limitations of significant embolic reflux. This may reduce bleeding risk during spinal surgery. Eleven consecutive cases of preoperative Onyx embolization of extrinsic spinal tumors were identified, all of whom had subsequent spinal surgery. Demographic data and clinical variables were collected. Patients were divided into Scepter (n=6) and non-Scepter (n=5) groups. The Mann-Whitney U test was used to compare continuous outcome variables and the Fisher exact test was used to compare categorical variables. Estimated blood loss in the Scepter group was significantly lower than in the non-Scepter group (584±124 vs 2400±738 mL, p=0.004). The volume of intraoperative transfusion was also significantly lower (1.2±0.4 vs 5.8±1.7 units, p=0.004). There was no significant difference in the number of vessels embolized, vials of Onyx used, use of coiling adjunct, contrast load, radiation dose, or fluoroscopy time per pedicle (p>0.05). The addition of the Scepter catheter to preoperative Onyx embolization is safe and feasible. In this small series, the Scepter catheter was associated with a reduction of intraoperative bleeding by 76% and a 79% lower transfusion volume. This was not accompanied by any unwanted increase in vials of Onyx used, contrast load, radiation dose, or fluoroscopy time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Blood Test: Immunoglobulin A (IgA)
... before this test. On the day of the test, having your child wear a T-shirt or short-sleeved shirt can ... The blood sample will be processed by a machine. The results are commonly ... further tests. Risks This test is considered a safe procedure. ...
Contact Dermatitis to Personal Sporting Equipment in Youth.
Marzario, Barbara; Burrows, Dianne; Skotnicki, Sandy
2016-07-01
Contact dermatitis to personal sporting equipment in youth is poorly studied. To review the results of patch testing 6 youth to their sporting equipment in a dermatology general private practice from 2006 to 2011. A retrospective analysis of 6 youth aged 11 to 14 who were evaluated for chronic and persistent dermatitis occurring in relation to sports equipment was conducted. All patients were subjected to epicutaneous (patch) testing, which included some or all of the following: North American Contact Dermatitis Group (NACGD) series, textile series, rubber series, corticosteroid series, and raw material from the patients' own personal equipment. All cases had 1 or more positive patch test reactions to an allergen within the aforementioned series, and 3 subjects tested positive to their personal equipment in raw form. Allergic contact dermatitis, not irritant, was deemed the relevant cause of chronic dermatitis in 4 of the 6 patients due to positive reactions to epicutaneous tests and/or personal equipment. The utility of testing to patients' own sporting equipment was shown to be of additional value and should be considered when patch testing for contact allergy to sporting equipment. © The Author(s) 2015.
Results of the mission profile life test. [for J-series mercury ion engines
NASA Technical Reports Server (NTRS)
Bechtel, R. T.; Trump, G. E.; James, E. L.
1982-01-01
Seven J series 30-cm diameter thrusters have been tested in segments of up to 5,070 hr, for 14,541 hr in the Mission Profile Life Test facility. Test results have indicated the basic thruster design to be consistent with the lifetime goal of 15,000 hr at 2-A beam. The only areas of concern identified which appear to require additional verification testing involve contamination of mercury propellant isolators, which may be due to facility constituents, and the ability of specially covered surfaces to contain sputtered material and prevent flake formation. The ability of the SCR, series resonant inverter power processor to operate the J series thruster and autonomous computer control of the thruster/processor system were demonstrated.
Characterizing artifacts in RR stress test time series.
Astudillo-Salinas, Fabian; Palacio-Baus, Kenneth; Solano-Quinde, Lizandro; Medina, Ruben; Wong, Sara
2016-08-01
Electrocardiographic stress test records have a lot of artifacts. In this paper we explore a simple method to characterize the amount of artifacts present in unprocessed RR stress test time series. Four time series classes were defined: Very good lead, Good lead, Low quality lead and Useless lead. 65 ECG, 8 lead, records of stress test series were analyzed. Firstly, RR-time series were annotated by two experts. The automatic methodology is based on dividing the RR-time series in non-overlapping windows. Each window is marked as noisy whenever it exceeds an established standard deviation threshold (SDT). Series are classified according to the percentage of windows that exceeds a given value, based upon the first manual annotation. Different SDT were explored. Results show that SDT close to 20% (as a percentage of the mean) provides the best results. The coincidence between annotators classification is 70.77% whereas, the coincidence between the second annotator and the automatic method providing the best matches is larger than 63%. Leads classified as Very good leads and Good leads could be combined to improve automatic heartbeat labeling.
Heat Pipe Reactor Dynamic Response Tests: SAFE-100 Reactor Core Prototype
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.
2005-01-01
The SAFE-I00a test article at the NASA Marshall Space Flight Center was used to simulate a variety of potential reactor transients; the SAFEl00a is a resistively heated, stainless-steel heat-pipe (HP)-reactor core segment, coupled to a gas-flow heat exchanger (HX). For these transients the core power was controlled by a point kinetics model with reactivity feedback based on core average temperature; the neutron generation time and the temperature feedback coefficient are provided as model inputs. This type of non-nuclear test is expected to provide reasonable approximation of reactor transient behavior because reactivity feedback is very simple in a compact fast reactor (simple, negative, and relatively monotonic temperature feedback, caused mostly by thermal expansion) and calculations show there are no significant reactivity effects associated with fluid in the HP (the worth of the entire inventory of Na in the core is .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Core, Gregory Matthew
This report contains a summary of irradiation testing of Fuel Cycle Research and Development (FCRD) Accident Tolerant Fuels Series 1 (ATF 1) experiments performed at Idaho National Laboratory (INL) in FY 2016. ATF 1 irradiation testing work performed in FY 2016 included design, analysis, and fabrication of ATF-1B drop in capsule ATF 1 series experiments and irradiation testing of ATF-1 capsules in the ATR.
Performance of a fail-safe system to follow up abnormal mammograms in primary care.
Grossman, Ellie; Phillips, Russell S; Weingart, Saul N
2010-09-01
Missed and delayed breast cancer diagnoses are major sources of potential harm to patients and medical malpractice liability in the United States. Follow-up of abnormal mammogram results is an essential but challenging component of safe breast care. To explore the value of an inexpensive method to follow up abnormal test results, we examined a paper-based fail-safe system. We examined a fail-safe system used to follow up abnormal mammograms at a primary care practice at an urban teaching hospital. We analyzed all abnormal mammogram reports and clinicians' responses to follow-up reminders. We characterized potential lapses identified in this system and used regression models to identify patient, provider, and test result characteristics associated with such lapses. Clinicians responded to fail-safe reminders for 92% of 948 abnormal mammograms. Clinicians reported that they were unaware of the abnormal result in 8% of cases and that there was no follow-up plan in place for 3% of cases. Clinicians with more years of experience were more likely to be aware of the abnormal result (odds of being unaware per incremental year in practice, 0.92; 95% confidence interval, 0.88-0.97) and were more likely to have a follow-up plan. A paper-based fail-safe system for abnormal mammograms is feasible in a primary care practice. However, special care is warranted to ensure full clinician adherence and address staff transitions and trainee-related issues.
Using missing ordinal patterns to detect nonlinearity in time series data.
Kulp, Christopher W; Zunino, Luciano; Osborne, Thomas; Zawadzki, Brianna
2017-08-01
The number of missing ordinal patterns (NMP) is the number of ordinal patterns that do not appear in a series after it has been symbolized using the Bandt and Pompe methodology. In this paper, the NMP is demonstrated as a test for nonlinearity using a surrogate framework in order to see if the NMP for a series is statistically different from the NMP of iterative amplitude adjusted Fourier transform (IAAFT) surrogates. It is found that the NMP works well as a test statistic for nonlinearity, even in the cases of very short time series. Both model and experimental time series are used to demonstrate the efficacy of the NMP as a test for nonlinearity.
Disgust- and anxiety-based emotional reasoning in non-clinical fear of vomiting.
Verwoerd, Johan; van Hout, Wiljo J P J; de Jong, Peter J
2016-03-01
Emotional reasoning has been described as a dysfunctional tendency to use subjective responses to make erroneous inferences about threatening outcomes in objectively safe situations (e.g., "If I feel anxious/disgusted, there must be danger/risk of becoming ill"). Prior studies found evidence for anxiety-based emotional reasoning (ER) in several anxiety disorders as well as disgust-based ER in healthy individuals scoring above the clinical cut-off on a measure of contamination fear. The current study tested whether disgust- and anxiety-based ER might be involved in fear of vomiting, a phobic disorder in which both fear/anxiety and disgust are assumed to play an important role. Non-clinical participants scoring high (>75%; n = 35) and low (<25%; n = 38) on a measure of fear of vomiting were presented with a series of scripts describing objectively safe everyday situations that systematically varied in the absence/presence of the actor's disgust/anxiety response. Following each script, participants rated their perceived danger and threat of contamination/illness. In line with hypotheses, specifically high vomit-fearful individuals used experienced disgust and anxiety to overestimate risk of becoming ill. Follow up analyses taking into account shared variance between both emotions revealed that more pronounced ER in the high vomit fearful group was mainly driven by the emotion of disgust. Current study asked participants to imagine experienced emotions in scenarios instead of experimentally inducing real-life emotions. These findings are consistent with the view that disgust-based ER is involved in fear of vomiting. Copyright © 2015 Elsevier Ltd. All rights reserved.
Singh, Jagbir; Yang, Peng; Michel, Deborah; Verrall, Ronald E; Foldvari, Marianna; Badea, Ildiko
2011-05-01
Gene based therapy represents an important advance in the treatment of diseases that heretofore have had either no treatment or cure. To capitalize on the true potential of gene therapy, there is a need to develop better delivery systems that can protect these therapeutic biomolecules and deliver them safely to the target sites. Recently, we have designed and developed a series of novel amino acid-substituted gemini surfactants with the general chemical formula C(12)H(25) (CH(3))(2)N(+)-(CH(2))(3)-N(AA)-(CH(2))(3)-N(+) (CH(3))(2)-C(12)H(25) (AA= glycine, lysine, glycyl-lysine and, lysyl-lysine). These compounds were synthesized and tested in rabbit epithelial cells using a model plasmid and a helper lipid. Plasmid/gemini/lipid (P/G/L) nanoparticles formulated using these novel compounds achieved higher gene expression than the nanoparticles containing the parent unsubstituted compound. In this study, we evaluated the cytotoxicity of P/G/L nanoparticles and explored the relationship between transfection efficiency/toxicity and their physicochemical characteristics (such as size, binding properties, etc.). An overall low toxicity is observed for all complexes with no significant difference among substituted and unsubstituted compounds. An interesting result revealed by the dye exclusion assay suggests a more balanced protection of the DNA by the glycine and glycyl-lysine substituted compounds. Thus, the higher transfection efficiency is attributed to the greater biocompatibility and flexibility of the amino acid/peptide-substituted gemini surfactants and demonstrates the feasibility of using amino acid-substituted gemini surfactants as gene carriers for the treatment of diseases affecting epithelial tissue.
ERIC Educational Resources Information Center
Science Teacher, 1989
1989-01-01
Reviews seven software programs: (1) "Science Baseball: Biology" (testing a variety of topics); (2) "Wildways: Understanding Wildlife Conservation"; (3) "Earth Science Computer Test Bank"; (4) "Biology Computer Test Bank"; (5) "Computer Play & Learn Series" (a series of drill and test…
Laser-assisted corneal welding in cataract surgery: retrospective study.
Menabuoni, Luca; Pini, Roberto; Rossi, Francesca; Lenzetti, Ivo; Yoo, Sonia H; Parel, Jean-Marie
2007-09-01
To evaluate the efficacy of laser welding to close corneal wounds in cataract surgery. Department of Ophthalmology, Hospital of Misericordia e Dolce, Prato, Italy. This retrospective nonrandomized interventional case series included 20 eyes of 20 patients. All eyes had cataract with visual acuity worse than 20/200. Ten patients had phacoemulsification surgery, and 10 had extracapsular cataract extraction (ECCE). Surgeries were followed by laser-assisted closure of the corneal wounds by diode laser welding of the stroma using a technique established in animal models. Preoperative and postoperative (1, 3, 7, 30, and 90 days) astigmatism, level of inflammation, Seidel testing, and endothelial cell counts were obtained. There were minor differences in preoperative and postoperative astigmatism except in 1 eye in the ECCE group. The Seidel test showed no wound leakage during the follow-up examinations, and endothelial cell loss was similar to that published for standard surgical cataract procedures. No collateral effects of the laser welding were detected, nor was postoperative inflammation. Astigmatism was slightly affected by the use of laser welding for corneal wound closure after phacoemulsification and ECCE. The laser-assisted corneal sealing procedure was rapid and safe and could serve as an alternative to corneal suturing, with significant potential applications for the closure of longer incisions, such as those used in penetrating keratoplasty.
Airport Surface Movement Technologies: Atlanta Demonstrations Overview
NASA Technical Reports Server (NTRS)
Jones, Denise R.; Young, Steven D.
1997-01-01
A flight demonstration was conducted in August 1997 at the Hartsfield Atlanta (ATL) International Airport as part of low visibility landing and surface operations (LVLASO) research activities. This research was aimed at investigating technology to improve the safety and efficiency of aircraft movements on the surface during the operational phases of roll-out, turnoff, and taxi in any weather condition down to a runway visual range of 300 feet. The system tested at ATL was composed of airborne and ground-based components that were integrated to provide both the flight crew and controllers with supplemental information to enable safe, expedient surface operations. Experimental displays were installed on a Boeing 757-200 research aircraft in both headup and head-down formats. On the ground, an integrated system maintained surveillance of the airport surface and a controller interface provided routing and control instructions. While at ATL, the research aircraft performed a series of flight and taxi operations to show the validity of the operational concept at a major airport facility, to validate simulation findings, and to assess each of the individual technologies performance in an airport environment. The concept was demonstrated to over 100 visitors from the Federal Aviation Administration (FAA) and the aviation community. This paper gives an overview of the LVLASO system and ATL test activities.
Garcia, Bryan; Sharma, Nirmal; Johnson, Kevin; Salgado, Juan; Wille, Keith
2017-10-31
Paramyxoviruses contribute to morbidity and mortality after lung transplant and are associated with bronchiolitis obliterans syndrome. Oral ribavirin has been used off-label for treatment of paramyxoviruses in immunosuppressed patients; however, data supporting its use for this purpose are lacking. We conducted a retrospective review to evaluate clinical outcomes of lung transplant recipients infected with paramyxoviruses and received treatment with oral ribavirin at 2 tertiary referral centers. Patients who were diagnosed with paramyxovirus infection by polymerase chain reaction testing between January 2011 and December 2014 and who received oral ribavirin were included. Clinical outcomes included pulmonary function testing, infection severity, and adverse events related to treatment. Twenty-six patients were diagnosed with a paramyxovirus and received oral ribavirin. The changes in mean forced expiratory volume 1 second from preinfection to infection onset and from infection onset to postinfection were significant (1.79 ± 0.13 to 1.61 ± 0.12 L and 1.61 ± 0.12L to 1.74 ± 0.12 L; P = .0001). Similar results were seen in subgroup analysis when respiratory syncytial virus and parainfluenza infections were evaluated independently. Use of oral ribavirin for treatment of paramyxovirus infections in lung transplant recipients was safe and associated with recovery of lung function.
2012-04-20
CAPE CANAVERAL, Fla. – The van transporting the cargo bag packed with NanoRacks-CubeLabs Module-9 experiments, arrives at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida for cold stowage. The bag will be loaded into the Space Exploration Technologies Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. NanoRacks-CubeLabs Module-9 uses a two-cube unit box for student competition investigations using 15 liquid mixing tube assemblies that function similar to commercial glow sticks. The investigations range from microbial growth to water purification in microgravity. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the module and other cargo will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-19
CAPE CANAVERAL, Fla. – In the Space Station Processing Facility at NASA’s Kennedy Space Center in Florida, refrigerated NanoRacks-CubeLabs Module-9 experiments are being prepared for transport to Space Launch Complex-40 on nearby Cape Canaveral Air Force Station. There, the bags will be loaded into the Space Exploration Technologies Dragon capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. NanoRacks-CubeLabs Module-9 uses a two-cube unit box for student competition investigations using 15 liquid mixing tube assemblies that function similar to commercial glow sticks. The investigations range from microbial growth to water purification in microgravity. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the module and other cargo will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
Test results of the highly instrumented Space Shuttle Main Engine
NASA Technical Reports Server (NTRS)
Mcconnaughey, H. V.; Leopard, J. L.; Lightfoot, R. M.
1992-01-01
Test results of a highly instrumented Space Shuttle Main Engine (SSME) are presented. The instrumented engine, when combined with instrumented high pressure turbopumps, contains over 750 special measurements, including flowrates, pressures, temperatures, and strains. To date, two different test series, accounting for a total of sixteen tests and 1,667 seconds, have been conducted with this engine. The first series, which utilized instrumented turbopumps, characterized the internal operating environment of the SSME for a variety of operating conditions. The second series provided system-level validation of a high pressure liquid oxygen turbopump that had been retrofitted with a fluid-film bearing in place of the usual pump-end ball bearings. Major findings from these two test series are highlighted in this paper. In addition, comparisons are made between model predictions and measured test data.
Strep Test: Throat Culture (For Parents)
... Fitness Diseases & Conditions Infections Drugs & Alcohol School & Jobs Sports Expert Answers (Q&A) Staying Safe Videos for Educators Search English Español Strep Test: Throat Culture KidsHealth / For Parents / Strep Test: Throat Culture What's ...
Subsidence Evaluation of High-Speed Railway in Shenyang Based on Time-Series Insar
NASA Astrophysics Data System (ADS)
Zhang, Yun; Wei, Lianhuan; Li, Jiayu; Liu, Shanjun; Mao, Yachun; Wu, Lixin
2018-04-01
More and more high-speed railway are under construction in China. The slow settlement along high-speed railway tracks and newly-built stations would lead to inhomogeneous deformation of local area, and the accumulation may be a threat to the safe operation of high-speed rail system. In this paper, surface deformation of the newly-built high-speed railway station as well as the railway lines in Shenyang region will be retrieved by time series InSAR analysis using multi-orbit COSMO-SkyMed images. This paper focuses on the non-uniform subsidence caused by the changing of local environment along the railway. The accuracy of the settlement results can be verified by cross validation of the results obtained from two different orbits during the same period.
Flutter Analysis of the Shuttle Tile Overlay Repair Concept
NASA Technical Reports Server (NTRS)
Bey, Kim S.; Scott, Robert C.; Bartels, Robert E.; Waters, William A.; Chen, Roger
2007-01-01
The Space Shuttle tile overlay repair concept, developed at the NASA Johnson Space Center, is designed for on-orbit installation over an area of damaged tile to permit safe re-entry. The thin flexible plate is placed over the damaged area and secured to tile at discreet points around its perimeter. A series of flutter analyses were performed to determine if the onset of flutter met the required safety margins. Normal vibration modes of the panel, obtained from a simplified structural analysis of the installed concept, were combined with a series of aerodynamic analyses of increasing levels of fidelity in terms of modeling the flow physics to determine the onset of flutter. Results from these analyses indicate that it is unlikely that the overlay installed at body point 1800 will flutter during re-entry.
NASA Technical Reports Server (NTRS)
Shane, S. J.
1985-01-01
The unacceptably high injury rate during the escape sequence (including the ejection and ground impact) of the crew module for F/FB-111 aircraft is reviewed. A program to determine if the injury potential could be reduced by replacing the existing crewseats with energy absorbing crewseats is presented. An energy absorbing test seat is designed using much of the existing seat hardware. An extensive dynamic seat test series, designed to duplicate various crew module ground impact conditions is conducted at a sled test facility. Comparative tests with operational F-111 crewseats are also conducted. After successful dynamic testing of the seat, more testing is conducted with the seats mounted in an F-111 crew module. Both swing tests and vertical drop tests are conducted. The vertical drop tests are used to obtain comparative data between the energy absorbing and operational seats. Volume 1 describes the energy absorbing test seat and testing conducted, and evaluates the data from both test series. Volume 2 presents the data obtained during the seat test series, while Volume 3 presents the data from the crew module test series.
Synthesis and biological evaluation of a series of non-hemiacetal ester derivatives of artemisinin.
Zuma, Nonkululeko H; Smit, Frans J; de Kock, Carmen; Combrinck, Jill; Smith, Peter J; N'Da, David D
2016-10-21
In an attempt to improve the efficacy and stability of current, clinically used artemisinins, a series non-hemiacetal ester derivatives of artemisinin were synthesized and evaluated for their in vitro antiplasmodial and anticancer activities as well as cytotoxicities. These esters were synthesized through the reaction of acid anhydrides, or acid chlorides with artemisinin derived alcohol. In vitro antiplasmodial activity assessments were conducted against intraerythrocytic NF54 and Dd2 Plasmodium falciparum strains. Cytotoxicities were assessed, using normal human fetal lung fibroblast (WI-38) and Chinese hamster ovarian (CHO) mammalian cell lines, while anticancer activities were tested by using panels with three cell lines, consisting of renal (TK10), melanoma (UACC62) and breast (MCF7) cancer cells. Most compounds were found active against the breast cancer cell line. Since antiplasmodial activities for most compounds were found comparable only to that of artesunate, this study did not yield any esters with significantly improved antimalarial efficacies, nor did it deliver any promising antitumor hits. However, from the outcomes of this study, compounds with good safety profiles and increased thermal stabilities, compared to the clinically used artemisinins, were identified. The benzoate derivative 11 was found to have antimalarial activity, comparable to that of dihydroartemisinin and was it subsequently identified as a candidate for further investigation in the urgent search for new, safe and effective antimalarial drugs. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
ERIC Educational Resources Information Center
National Center for Homeless Education at SERVE, 2015
2015-01-01
Each year, over 1.2 million children and youth identified as homeless in the nation's schools experience educational disruption that is caused by not having a safe and stable place to live (NCHE, 2014). Homeless children and youth face educational challenges that include a lack of basic necessities, such as food, clothing, and medical services;…
ERIC Educational Resources Information Center
National Center for Homeless Education at SERVE, 2015
2015-01-01
Each year, over 1.2 million children and youth identified as homeless in the nation's schools experience the educational disruption that is caused by not having a safe and stable place to live (NCHE, 2014). Homeless children and youth face educational challenges that include a lack of basic necessities, such as food, clothing, and medical…
Shankar, Abhishek; Rath, Gk; Roy, Shubham; Malik, Abhidha; Bhandari, Ruchir; Kishor, Kunal; Barnwal, Keshav; Upadyaya, Sneha; Srivastava, Vivek; Singh, Rajan
2015-01-01
Breast and cervical cancers are the most common causes of cancer mortality among women in India, but actually they are largely preventable diseases. Although early detection is the only way to reduce morbidity and mortality, there are limited data on breast and cervical cancer knowledge, safe practices and attitudes of teachers in India. The purpose of this study is to assess the level of awareness and impact of awareness programs in adoption of safe practices in prevention and early detection. This assessment was part of a pink chain campaign on cancer awareness. During cancer awareness events in 2011 at various women colleges in different parts in India, a pre-test related to cervical cancer and breast cancer was followed by an awareness program. Post-tests using the same questionnaire were conducted at the end of the interactive session, at 6 months and 1 year. A total of 156 out of 182 teachers participated in the study (overall response rate was 85.7 %). Mean age of the study population was 42.4 years (range- 28-59 yrs). There was a significant increase in level of knowledge regarding cervical and breast cancer at 6 months and this was sustained at 1 year. Adoption of breast self examination (BSE) was significantly more frequent in comparison to CBE, mammography and the Pap test. Magazines and newspapers were sources for knowledge regarding screening tests for breast cancer in more than 60% of teachers where as more than 75% were educated by doctors regarding the Pap test. Post awareness at 6 months and 1 year, there was a significant change in alcohol and smoking habits. Major reasons for not doing screening test were found to be ignorance (50%), lethargic attitude (44.8%) and lack of time (34.6%). Level of knowledge of breast cancer risk factors, symptoms and screening methods was high as compared to cervical cancer. There was a significant increase in level of knowledge regarding cervical and breast cancer at 6 months and this was sustained at 1 year. Adoption of BSE was significantly greater in comparison to CBE, mammography and the Pap test. To inculcate safe practices in lifestyle of people, awareness programmes such as pink chain campaign should be conducted more widely and frequently.
Assessment Guide for Educators: A Content Comparison--2002 Series Test and the Current GED® Test
ERIC Educational Resources Information Center
GED Testing Service, 2017
2017-01-01
This report provides a content comparison for the 2002 Series GED® test and the current GED® for the following test topic areas: (1) Mathematical Reasoning; (2) Reasoning through Language Arts; (3) Science; and (4) Social Studies.
Litchfield, Ian; Bentham, Louise; Hill, Ann; McManus, Richard J; Lilford, Richard; Greenfield, Sheila
2015-01-01
Background The testing and result communication process in primary care is complex. Its successful completion relies on the coordinated efforts of a range of staff in primary care and external settings working together with patients. Despite the importance of diagnostic testing in provision of care, this complexity renders the process vulnerable in the face of increasing demand, stretched resources and a lack of supporting guidance. Methods We conducted a series of focus groups with patients and staff across four primary care practices using process-improvement strategies to identify and understand areas where either unnecessary delay is introduced, or the process may fail entirely. We then worked with both patients and staff to arrive at practical strategies to improve the current system. Results A total of six areas across the process were identified where improvements could be introduced. These were: (1) delay in phlebotomy, (2) lack of a fail-safe to ensure blood tests are returned to practices and patients, (3) difficulties in accessing results by telephone, (4) role of non-clinical staff in communicating results, (5) routine communication of normal results and (6) lack of a protocol for result communication. Conclusions A number of potential failures in testing and communicating results to patients were identified, and some specific ideas for improving existing systems emerged. These included same-day phlebotomy sessions, use of modern technology methods to proactively communicate routine results and targeted training for receptionists handling sensitive data. There remains an urgent need for further work to test these and other potential solutions. PMID:26251507
Litchfield, Ian; Bentham, Louise; Hill, Ann; McManus, Richard J; Lilford, Richard; Greenfield, Sheila
2015-11-01
The testing and result communication process in primary care is complex. Its successful completion relies on the coordinated efforts of a range of staff in primary care and external settings working together with patients. Despite the importance of diagnostic testing in provision of care, this complexity renders the process vulnerable in the face of increasing demand, stretched resources and a lack of supporting guidance. We conducted a series of focus groups with patients and staff across four primary care practices using process-improvement strategies to identify and understand areas where either unnecessary delay is introduced, or the process may fail entirely. We then worked with both patients and staff to arrive at practical strategies to improve the current system. A total of six areas across the process were identified where improvements could be introduced. These were: (1) delay in phlebotomy, (2) lack of a fail-safe to ensure blood tests are returned to practices and patients, (3) difficulties in accessing results by telephone, (4) role of non-clinical staff in communicating results, (5) routine communication of normal results and (6) lack of a protocol for result communication. A number of potential failures in testing and communicating results to patients were identified, and some specific ideas for improving existing systems emerged. These included same-day phlebotomy sessions, use of modern technology methods to proactively communicate routine results and targeted training for receptionists handling sensitive data. There remains an urgent need for further work to test these and other potential solutions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Diabetes and Exercise: When to Monitor Your Blood Sugar
... go. For most people, this is a safe pre-exercise blood sugar range. 250 mg/dL (13.9 mmol/L) or higher. This is a caution zone — Your blood sugar may be too high to exercise safely. Before exercising, test your urine for ketones — substances made when your ...
Rosenberg, Nora E; Graybill, Lauren A; Wesevich, Austin; McGrath, Nuala; Golin, Carol E; Maman, Suzanne; Bhushan, Nivedita; Tsidya, Mercy; Chimndozi, Limbikani; Hoffman, Irving F; Hosseinipour, Mina C; Miller, William C
2017-08-01
In sub-Saharan Africa couple HIV testing and counseling (CHTC) has been associated with substantial increases in safe sex, especially when at least one partner is HIV infected. However, this relationship has not been characterized in an Option B+ context. The study was conducted at the antenatal clinic at Bwaila District Hospital in Lilongwe, Malawi in 2016 under an Option B+ program. Ninety heterosexual couples with an HIV-infected pregnant woman (female-positive couples) and 47 couples with an HIV-uninfected pregnant woman (female-negative couples) were enrolled in an observational study. Each couple member was assessed immediately before and 1 month after CHTC for safe sex (abstinence or consistent condom use in the last month). Generalized estimating equations were used to model change in safe sex before and after CHTC and to compare safe sex between female-positive and female-negative couples. Mean age was 26 years among women and 32 years among men. Before CHTC, safe sex was comparable among female-positive couples (8%) and female-negative couples (2%) [risk ratio (RR): 3.7, 95% confidence interval (CI): 0.5 to 29.8]. One month after CHTC, safe sex was higher among female-positive couples (75%) than among female-negative couples (3%) (RR: 30.0, 95% CI: 4.3 to 207.7). Safe sex increased substantially after CTHC for female-positive couples (RR 9.6, 95% CI: 4.6 to 20.0), but not for female-negative couples (RR: 1.2, 95% CI: 0.1 to 18.7). Engaging pregnant couples in CHTC can have prevention benefits for couples with an HIV-infected pregnant woman, but additional prevention approaches may be needed for couples with an HIV-uninfected pregnant woman.
Access to Safe Water in Rural Artibonite, Haiti 16 Months after the Onset of the Cholera Epidemic
Patrick, Molly; Berendes, David; Murphy, Jennifer; Bertrand, Fabienne; Husain, Farah; Handzel, Thomas
2013-01-01
Haiti has the lowest improved water and sanitation coverage in the Western Hemisphere and is suffering from the largest cholera epidemic on record. In May of 2012, an assessment was conducted in rural areas of the Artibonite Department to describe the type and quality of water sources and determine knowledge, access, and use of household water treatment products to inform future programs. It was conducted after emergency response was scaled back but before longer-term water, sanitation, and hygiene activities were initiated. The household survey and source water quality analysis documented low access to safe water, with only 42.3% of households using an improved drinking water source. One-half (50.9%) of the improved water sources tested positive for Escherichia coli. Of households with water to test, 12.7% had positive chlorine residual. The assessment reinforces the identified need for major investments in safe water and sanitation infrastructure and the importance of household water treatment to improve access to safe water in the near term. PMID:24106191
Simulation of prenatal maternal sounds in NICU incubators: a pilot safety and feasibility study.
Panagiotidis, John; Lahav, Amir
2010-10-01
This pilot study evaluated the safety and feasibility of an innovative audio system for transmitting maternal sounds to NICU incubators. A sample of biological sounds, consisting of voice and heartbeat, were recorded from a mother of a premature infant admitted to our unit. The maternal sounds were then played back inside an unoccupied incubator via a specialized audio system originated and compiled in our lab. We performed a series of evaluations to determine the safety and feasibility of using this system in NICU incubators. The proposed audio system was found to be safe and feasible, meeting criteria for humidity and temperature resistance, as well as for safe noise levels. Simulation of maternal sounds using this system seems achievable and applicable and received local support from medical staff. Further research and technology developments are needed to optimize the design of the NICU incubators to preserve the acoustic environment of the womb.
Implementation of the NANoREG Safe-by-Design approach for different nanomaterial applications
NASA Astrophysics Data System (ADS)
Micheletti, C.; Roman, M.; Tedesco, E.; Olivato, I.; Benetti, F.
2017-06-01
The Safe-by-Design (SbD) concept is already in use in different industrial sectors as an integral part of the innovation process management. However, the adopted approach is often limited to design solutions aiming at hazard reduction. Safety is not always considered during the innovation process, mainly due to the lack of knowledge (e.g. in small and medium companies, SMEs) and the lack of dialogue between actors along the innovation chain. The net result is that safety is considered only at the end of the innovation process at the market authorization phase, with potential loss of time and money. This is especially valid for manufactured nanomaterials (MNM) for which the regulatory context is not completely developed, and the safety knowledge is not readily available. In order to contribute to a sustainable innovation process in the nanotechnology field by maximising both benefits and safety, the NANoREG project developed a Safe Innovation approach, based on two elements: the Safe-by-Design approach which aims at including risk assessment into all innovation stages; and the Regulatory Preparedness, focused on the dialogue with stakeholders along the innovation chain. In this work we present some examples about the implementation in our Laboratory of this approach for different MNM applications, covering different steps of the innovation chain. The case studies include: the feasibility study of a medical device including substances, for topical application; the testing of two potential nanotech solutions for the consolidation of cultural heritage artifacts; the testing of coatings already on the market for other uses, which was tested as food contact materials (FCM) to evaluate the conformity to food applications. These three examples represent a good opportunity to show the importance of NANoREG SbD and Safe Innovation Approach in general, for developing new nanotechnology-based products, also highlighting the crucial role of EU ProSafe project in promoting this concept to industries and interested stakeholders.
Hazard-Free Pyrotechnic Simulator
NASA Technical Reports Server (NTRS)
Mcalister, William B., Jr.
1988-01-01
Simulator evaluates performance of firing circuits for electroexplosive devices (EED's) safely and inexpensively. Tests circuits realistically when pyrotechnic squibs not connected and eliminates risks of explosions. Used to test such devices as batteries where test conditions might otherwise degrade them.
Fragrance contact allergy: a 4-year retrospective study.
Cuesta, Laura; Silvestre, Juan Francisco; Toledo, Fernando; Lucas, Ana; Pérez-Crespo, María; Ballester, Irene
2010-08-01
Fragrance chemicals are the second most frequent cause of contact allergy. The mandatory labelling of 26 fragrance chemicals when present in cosmetics has facilitated management of patients allergic to fragrances. The study was aimed to define the characteristics of the population allergic to perfumes detected in our hospital district, to determine the usefulness of markers of fragrance allergy in the baseline GEIDAC series, and to describe the contribution made by the fragrance series to the data obtained with the baseline series. We performed a 4-year retrospective study of patients tested with the Spanish baseline series and/or fragrance series. There are four fragrance markers in the baseline series: fragrance mix I (FM I), Myroxylon pereirae, fragrance mix II (FM II), and hydroxyisohexyl 3-cyclohexene carboxaldehyde. A total of 1253 patients were patch tested, 117 (9.3%) of whom were positive to a fragrance marker. FM I and M. pereirae detected 92.5% of the cases of fragrance contact allergy. FM II and hydroxyisohexyl 3-cyclohexene carboxaldehyde detected 6 additional cases and provided further information in 8, enabling improved management. A fragrance series was tested in a selected group of 86 patients and positive results were obtained in 45.3%. Geraniol was the allergen most frequently found in the group of patients tested with the fragrance series. Classic markers detect the majority of cases of fragrance contact allergy. We recommend incorporating FM II in the Spanish baseline series, as in the European baseline series, and using a specific fragrance series to study patients allergic to a fragrance marker.
Ohira, Masayuki; Silcox, Jade; Haygood, Deavin; Harper-King, Valerie; Alsharabati, Mohammad; Lu, Liang; Morgan, Marla B; Young, Angela M; Claussen, Gwen C; King, Peter H; Oh, Shin J
2013-01-01
We compared the problems or complications associated with electrodiagnostic testing in 77 patients with implanted cardiac devices. Thirty tests were performed after magnet placement, and 47 were performed without magnet application. All electrodiagnostic tests were performed safely in all patients without any serious effect on the implanted cardiac devices with or without magnet placement. A significantly higher number of patient symptoms and procedure changes were reported in the magnet group (P < 0.013). No statistical difference was found in the testing difficulty or ECG changes. The magnet group patients had an approximately 11-fold greater risk of symptoms than those in the control group. Our data do not support a recommendation that magnet placement is necessary for routine electrodiagnostic testing in patients with implanted cardiac devices, as long as our general and specific guidelines are followed. Copyright © 2012 Wiley Periodicals, Inc.
Cognitive abilities of children on a gray seriation test.
Dain, Stephen J; Ling, Barbara Y
2009-06-01
The importance of testing children's color vision, particularly to identify color vision deficiencies at an early age, has long been agreed on by teachers and color vision researchers and healthcare workers. The classic color vision tests were not necessarily developed for children's cognitive abilities, even though they are commonly used to assess children's color vision. Although, in the past, psychologists have studied color seriation abilities of children, they have not necessarily chosen isoluminous stimuli, which would minimize brightness cues. This investigation was designed to assess the ability of children to seriate a gray series. Tests were constructed in the form of the Farnsworth-Munsell style of arrangement test with constant intervals of metric lightness (CIE L*). Four intervals (DeltaL* = 15, 10, 5, and 3) were used. The child was instructed to arrange the colors from darker to lighter (or vice versa). Errors were not made on the DeltaL* = 15 series. Only isolated errors were made on the DeltaL* = 10 series. Errors were made on the DeltaL* = 5 series that diminished with age to nil in the older groups. Errors were made on the DeltaL* = 3 series at all ages studied, which also diminished with increasing age. Children aged 5 to 12 have sufficiently grasped the concept of seriation. They are able to complete a series with DeltaL* = 5, hence are capable of performing color arrangement tests with similar color differences such as the Lanthony New Color Test and the Farnsworth-Munsell D-15. Given the large number of errors made on DeltaL* = 3 series, it may be concluded that children's performance on the 100-hue test, at least to the age of 12 years, could be unduly influenced by non-color vision factors.
Enraf Series 854 advanced technology gauge (ATG) acceptance test procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huber, J.H.
1996-09-11
This Acceptance Test Procedure was written to test the Enraf Series 854 Advanced Technology Gauge (ATG) prior to installation in the Tank Farms. The procedure sets various parameters and verifies that the gauge is functional.
Violano, Pina; Bonne, Stephanie; Duncan, Thomas; Pappas, Peter; Christmas, A Britton; Dennis, Andrew; Goldberg, Stephanie; Greene, Wendy; Hirsh, Michael; Shillinglaw, William; Robinson, Bryce; Crandall, Marie
2018-03-08
Over 50,000 homicides and suicides occur each year. An estimated half of all U.S. households are believed to have a firearm present, making them one of the most ubiquitous consumer products. Our goal was to determine if the manner of storage of a firearm in a home could potentially make a difference in the outcomes of intentional and unintentional injuries involving a firearm; specifically addressing the use of gun safes and devices that block/disable firearm function (trigger locks, cable locks, etc.). A comprehensive review of the literature was performed. We used GRADE (Grading of Recommendations Assessment, Development, and Evaluation) methodology to assess the breadth and quality of the data specific to our PICO (Population, Intervention, Comparator, Outcomes) questions. A total of 176 studies were initially identified, then 120 more added after a subsequent, literature review with 97 removed as duplicates. One hundred and ninety-one case reports, case series, and reviews were removed because they did not focus on prevention or did not address our comparators of interest. This left a total of two studies which merited inclusion for PICO #1, should gun locks be used to prevent firearm injuries and six studies which merited inclusion for PICO #2, should safe storage for guns be used to prevent firearm injuries. PICO 1: We conditionally recommend that gun locks be used to prevent unintentional firearm injury.PICO 2: Because of the large effect size and the reasonable quality of available evidence with safe storage of firearms, we recommend safe storage prevent firearm-related injuries. Systematic review, level III.
An improved portmanteau test for autocorrelated errors in interrupted time-series regression models.
Huitema, Bradley E; McKean, Joseph W
2007-08-01
A new portmanteau test for autocorrelation among the errors of interrupted time-series regression models is proposed. Simulation results demonstrate that the inferential properties of the proposed Q(H-M) test statistic are considerably more satisfactory than those of the well known Ljung-Box test and moderately better than those of the Box-Pierce test. These conclusions generally hold for a wide variety of autoregressive (AR), moving averages (MA), and ARMA error processes that are associated with time-series regression models of the form described in Huitema and McKean (2000a, 2000b).
Testing for intracycle determinism in pseudoperiodic time series.
Coelho, Mara C S; Mendes, Eduardo M A M; Aguirre, Luis A
2008-06-01
A determinism test is proposed based on the well-known method of the surrogate data. Assuming predictability to be a signature of determinism, the proposed method checks for intracycle (e.g., short-term) determinism in the pseudoperiodic time series for which standard methods of surrogate analysis do not apply. The approach presented is composed of two steps. First, the data are preprocessed to reduce the effects of seasonal and trend components. Second, standard tests of surrogate analysis can then be used. The determinism test is applied to simulated and experimental pseudoperiodic time series and the results show the applicability of the proposed test.
Defining the end-point of mastication: A conceptual model.
Gray-Stuart, Eli M; Jones, Jim R; Bronlund, John E
2017-10-01
The great risks of swallowing are choking and aspiration of food into the lungs. Both are rare in normal functioning humans, which is remarkable given the diversity of foods and the estimated 10 million swallows performed in a lifetime. Nevertheless, it remains a major challenge to define the food properties that are necessary to ensure a safe swallow. Here, the mouth is viewed as a well-controlled processor where mechanical sensory assessment occurs throughout the occlusion-circulation cycle of mastication. Swallowing is a subsequent action. It is proposed here that, during mastication, temporal maps of interfacial property data are generated, which the central nervous system compares against a series of criteria in order to be sure that the bolus is safe to swallow. To determine these criteria, an engineering hazard analysis tool, alongside an understanding of fluid and particle mechanics, is used to deduce the mechanisms by which food may deposit or become stranded during swallowing. These mechanisms define the food properties that must be avoided. By inverting the thinking, from hazards to ensuring safety, six criteria arise which are necessary for a safe-to-swallow bolus. A new conceptual model is proposed to define when food is safe to swallow during mastication. This significantly advances earlier mouth models. The conceptual model proposed in this work provides a framework of decision-making to define when food is safe to swallow. This will be of interest to designers of dietary foods, foods for dysphagia sufferers and will aid the further development of mastication robots for preparation of artificial boluses for digestion research. It enables food designers to influence the swallow-point properties of their products. For example, a product may be designed to satisfy five of the criteria for a safe-to-swallow bolus, which means the sixth criterion and its attendant food properties define the swallow-point. Alongside other organoleptic factors, these properties define the end-point texture and enduring sensory perception of the food. © 2017 Wiley Periodicals, Inc.
77 FR 15750 - Final Test Guidelines; OCSPP 810 Series; Notice of Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-16
... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OPP-2009-0681; FRL-9332-4] Final Test Guidelines; OCSPP.... SUMMARY: EPA is announcing the availability of the final test guidelines for Series 810--Product Performance Test Guidelines, specifically public health uses of antimicrobial agents (OCSPP 810.2000...
Surgical management of giant sphenoid wing meningiomas encasing major cerebral arteries.
Champagne, Pierre-Olivier; Lemoine, Emile; Bojanowski, Michel W
2018-04-01
OBJECTIVE Sphenoid wing meningiomas are a heterogeneous group of tumors with variable surgical risks and prognosis. Those that have grown to a very large size, encasing the major cerebral arteries, are associated with a high risk of stroke. In reviewing the authors' series of giant sphenoid wing meningiomas, the goal was to evaluate how the extent of the tumor's invasion of surrounding structures affected the ability to safely remove the tumor and restore function. METHODS The authors conducted a retrospective study of a series of giant sphenoid wing meningiomas operated on between 1996 and 2016. Inclusion criteria were meningiomas with a globoid component ≥ 6 cm, encasing at least 1 major intradural cerebral artery. Extent of resection was measured according to Simpson grade. RESULTS This series included 12 patients, with a mean age of 59 years. Visual symptoms were the most common clinical presentation. There was complete or partial encasement of all 3 major cerebral arteries except for 3 cases in which only the anterior cerebral artery was not involved. The lateral wall of the cavernous sinus was invaded in 8 cases (67%) and the optic canal in 6 (50%). Complete resection was achieved in 2 cases (Simpson grades 2 and 3). In the remaining 10 cases of partial resection (Simpson grade 4), radical removal (> 90%) was achieved in 7 cases (70%). In the immediate postoperative period, there were no deaths. Four of 9 patients with visual deficits improved, while the 5 others remained unchanged. Two patients experienced transient neurological deficits. Other than an asymptomatic lacuna of the internal capsule, there were no ischemic lesions following surgery. Tumor recurrence occurred in 5 patients, between 24 and 168 months (mean 61 months) following surgery. CONCLUSIONS Although these giant lesions encasing major cerebral arteries are particularly treacherous for surgery, this series demonstrates that it is possible to safely achieve radical removal and at times even gross-total resection. However, the risk of recurrence remains high and larger studies are needed to see if and how improvement can be achieved, whether in surgical technique or technological advances, and by determining the timing and modality of adjuvant radiation therapy.
Miceli, Luca; Bednarova, Rym; Rizzardo, Alessandro; Samogin, Valentina; Della Rocca, Giorgio
2015-01-01
Objective Italian Road Law limits driving while undergoing treatment with certain kinds of medication. Here, we report the results of a test, run as a smartphone application (app), assessing auditory and visual reflexes in a sample of 300 drivers. The scope of the test is to provide both the police force and medication-taking drivers with a tool that can evaluate the individual’s capacity to drive safely. Methods The test is run as an app for Apple iOS and Android mobile operating systems and facilitates four different reaction times to be assessed: simple visual and auditory reaction times and complex visual and auditory reaction times. Reference deciles were created for the test results obtained from a sample of 300 Italian subjects. Results lying within the first three deciles were considered as incompatible with safe driving capabilities. Results Performance is both age-related (r>0.5) and sex-related (female reaction times were significantly slower than those recorded for male subjects, P<0.05). Only 21% of the subjects were able to perform all four tests correctly. Conclusion We developed and fine-tuned a test called Safedrive that measures visual and auditory reaction times through a smartphone mobile device; the scope of the test is two-fold: to provide a clinical tool for the assessment of the driving capacity of individuals taking pain relief medication; to promote the sense of social responsibility in drivers who are on medication and provide these individuals with a means of testing their own capacity to drive safely. PMID:25709406
Miceli, Luca; Bednarova, Rym; Rizzardo, Alessandro; Samogin, Valentina; Della Rocca, Giorgio
2015-01-01
Italian Road Law limits driving while undergoing treatment with certain kinds of medication. Here, we report the results of a test, run as a smartphone application (app), assessing auditory and visual reflexes in a sample of 300 drivers. The scope of the test is to provide both the police force and medication-taking drivers with a tool that can evaluate the individual's capacity to drive safely. The test is run as an app for Apple iOS and Android mobile operating systems and facilitates four different reaction times to be assessed: simple visual and auditory reaction times and complex visual and auditory reaction times. Reference deciles were created for the test results obtained from a sample of 300 Italian subjects. Results lying within the first three deciles were considered as incompatible with safe driving capabilities. Performance is both age-related (r>0.5) and sex-related (female reaction times were significantly slower than those recorded for male subjects, P<0.05). Only 21% of the subjects were able to perform all four tests correctly. We developed and fine-tuned a test called Safedrive that measures visual and auditory reaction times through a smartphone mobile device; the scope of the test is two-fold: to provide a clinical tool for the assessment of the driving capacity of individuals taking pain relief medication; to promote the sense of social responsibility in drivers who are on medication and provide these individuals with a means of testing their own capacity to drive safely.
Washburne, Alex D.; Burby, Joshua W.; Lacker, Daniel; ...
2016-09-30
Systems as diverse as the interacting species in a community, alleles at a genetic locus, and companies in a market are characterized by competition (over resources, space, capital, etc) and adaptation. Neutral theory, built around the hypothesis that individual performance is independent of group membership, has found utility across the disciplines of ecology, population genetics, and economics, both because of the success of the neutral hypothesis in predicting system properties and because deviations from these predictions provide information about the underlying dynamics. However, most tests of neutrality are weak, based on static system properties such as species-abundance distributions or themore » number of singletons in a sample. Time-series data provide a window onto a system’s dynamics, and should furnish tests of the neutral hypothesis that are more powerful to detect deviations from neutrality and more informative about to the type of competitive asymmetry that drives the deviation. Here, we present a neutrality test for time-series data. We apply this test to several microbial time-series and financial time-series and find that most of these systems are not neutral. Our test isolates the covariance structure of neutral competition, thus facilitating further exploration of the nature of asymmetry in the covariance structure of competitive systems. Much like neutrality tests from population genetics that use relative abundance distributions have enabled researchers to scan entire genomes for genes under selection, we anticipate our time-series test will be useful for quick significance tests of neutrality across a range of ecological, economic, and sociological systems for which time-series data are available. Here, future work can use our test to categorize and compare the dynamic fingerprints of particular competitive asymmetries (frequency dependence, volatility smiles, etc) to improve forecasting and management of complex adaptive systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washburne, Alex D.; Burby, Joshua W.; Lacker, Daniel
Systems as diverse as the interacting species in a community, alleles at a genetic locus, and companies in a market are characterized by competition (over resources, space, capital, etc) and adaptation. Neutral theory, built around the hypothesis that individual performance is independent of group membership, has found utility across the disciplines of ecology, population genetics, and economics, both because of the success of the neutral hypothesis in predicting system properties and because deviations from these predictions provide information about the underlying dynamics. However, most tests of neutrality are weak, based on static system properties such as species-abundance distributions or themore » number of singletons in a sample. Time-series data provide a window onto a system’s dynamics, and should furnish tests of the neutral hypothesis that are more powerful to detect deviations from neutrality and more informative about to the type of competitive asymmetry that drives the deviation. Here, we present a neutrality test for time-series data. We apply this test to several microbial time-series and financial time-series and find that most of these systems are not neutral. Our test isolates the covariance structure of neutral competition, thus facilitating further exploration of the nature of asymmetry in the covariance structure of competitive systems. Much like neutrality tests from population genetics that use relative abundance distributions have enabled researchers to scan entire genomes for genes under selection, we anticipate our time-series test will be useful for quick significance tests of neutrality across a range of ecological, economic, and sociological systems for which time-series data are available. Here, future work can use our test to categorize and compare the dynamic fingerprints of particular competitive asymmetries (frequency dependence, volatility smiles, etc) to improve forecasting and management of complex adaptive systems.« less
Thyssen, Jacob P; Engkilde, Kåre; Menné, Torkil; Johansen, Jeanne D
2011-08-01
BACKGROUND. Allergens included in the European baseline series should result in positive patch test reactions in at least 1% of a patch test population. Inclusion of local anaesthetics other than benzocaine in the baseline series has previously been debated. To investigate temporal trends of benzocaine and lidocaine allergy in dermatitis patients who underwent routine patch testing in a tertiary referral patch test centre, and to clarify and discuss whether lidocaine and benzocaine should be included in routine series. Dermatitis patients who underwent routine patch testing with benzocaine as a part of the European baseline series between 1985 and 2010 (n = 19 347) and dermatitis patients who underwent routine patch testing with lidocaine between 1994 and 2001 (n = 6265) and between 2007 and 2009 (n = 1360) were included. The overall prevalences of contact allergy were 0.5% (benzocaine), 0.3% (lidocaine for the period 1994-2001), and 0.14% (lidocaine for the period 2007-2009). Current relevance was observed in 10% of those with benzocaine allergy and in 5% of those with lidocaine allergy. Benzocaine and lidocaine allergy is infrequent in Danish dermatitis patients. Lidocaine should only be used for aimed testing, and benzocaine should be removed from the baseline series used in Denmark. © 2011 John Wiley & Sons A/S.
Not just a drop in the bucket: expanding access to point-of-use water treatment systems.
Mintz, E; Bartram, J; Lochery, P; Wegelin, M
2001-10-01
Since 1990, the number of people without access to safe water sources has remained constant at approximately 1.1 billion, of whom approximately 2.2 million die of waterborne disease each year. In developing countries, population growth and migrations strain existing water and sanitary infrastructure and complicate planning and construction of new infrastructure. Providing safe water for all is a long-term goal; however, relying only on time- and resource-intensive centralized solutions such as piped, treated water will leave hundreds of millions of people without safe water far into the future. Self-sustaining, decentralized approaches to making drinking water safe, including point-of-use chemical and solar disinfection, safe water storage, and behavioral change, have been widely field-tested. These options target the most affected, enhance health, contribute to development and productivity, and merit far greater priority for rapid implementation.
Not Just a Drop in the Bucket: Expanding Access to Point-of-Use Water Treatment Systems
Mintz, Eric; Bartram, Jamie; Lochery, Peter; Wegelin, Martin
2001-01-01
Since 1990, the number of people without access to safe water sources has remained constant at approximately 1.1 billion, of whom approximately 2.2 million die of waterborne disease each year. In developing countries, population growth and migrations strain existing water and sanitary infrastructure and complicate planning and construction of new infrastructure. Providing safe water for all is a long-term goal; however, relying only on time- and resource-intensive centralized solutions such as piped, treated water will leave hundreds of millions of people without safe water far into the future. Self-sustaining, decentralized approaches to making drinking water safe, including point-of-use chemical and solar disinfection, safe water storage, and behavioral change, have been widely field-tested. These options target the most affected, enhance health, contribute to development and productivity, and merit far greater priority for rapid implementation. PMID:11574307
Belkin, Daniel A; Jeon, Hana; Weiss, Elliot; Brauer, Jeremy A; Geronemus, Roy G
2018-01-01
Nevus of Ota represents congenital dermal melanocytosis in a trigeminal distribution, most commonly occurring in Asian individuals and other individuals with skin of color. Evidence suggests early treatment is beneficial. Multiple reports have shown efficacy and safety of Q-switched laser treatment in adults. There is little data on children and in non-Asian skin types. This series was done to demonstrate safe and effective use of Q-switched laser therapy in children of multiple skin types. Retrospective case series. This was a chart review of patients under 18 years old who presented to our practice from 2002 to 2015 with a clinical diagnosis of nevus of Ota who were treated with Q-switched lasers (694 and 1,064 nm). Patients were treated without the use of general anesthesia or sedation, and corneal shields were used in appropriate cases. Percentage of improvement as well as side effects were rated by five physicians independently. Improvement, when present, was rated in quartiles (1-25%, 26-50%, 51-75%, and 76-100% improvement). Twenty-four children were included. The average age at the start of treatment was 3.9 years old (range of 3 months to 12.4 years), and patients had Fitzpatrick skin types IV through VI. The mean number of treatments was 9.3. Assessment revealed excellent response (76-100% improvement) in 70% of patients and good to excellent response (51-100% improvement) in 86%. Two patients (8%) had post-inflammatory hyperpigmentation, one of whom also had focal hypopigmentation. Treatment of nevus of Ota with Q-switched lasers in children with skin of color, without general anesthesia or sedation, is safe and effective. Early intervention should be encouraged for better efficacy and to prevent psychosocial distress in later childhood and adulthood. Lasers Surg. Med. 50:56-60, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
1994-01-01
A 10,000-pound thrust hybrid rocket motor is tested at Stennis Space Center's E-1 test facility. A hybrid rocket motor is a cross between a solid rocket and a liquid-fueled engine. It uses environmentally safe solid fuel and liquid oxygen.
NASA Technical Reports Server (NTRS)
1958-01-01
Canopy Model IV was tested in four different configuration series. Shroud lines were used in the first three series of tests; none were used in the fourth series. Other variables were Mach number (1.77, 2.17, 2.76), dynamic pressure (290, 250, 155 lb per sq ft), camera speed, and attitude.
2017-01-04
response, including the time for reviewing instructions, searching existing data sources, searching existing data sources, gathering and maintaining...configurations with a restrained manikin, was evaluated in four different test series . Test Series 1 was conducted to determine the materials and...5 ms TTP. Test Series 2 was conducted to determine the materials and drop heights required for energy attenuation of the seat pan to generate a 4 m
MISTY PICTURE EVENT, Test Execution Report
1987-11-30
testbed at overpressures ranging from 10 psi (83 kPa) to 3.4 psi (23 kPa). A series of experiments were positioned near the Thermal Radiation Sources...to include scheduling, construction, photography, and recording systems. (2) Formulate and direct the safety and security plans for the test series and...ANFO stacked charges multiburst test at Planet Ranch, AZ in 1978, e. MILL RACE (MISTY CASTLE Series I) - 600 ton ANFO surface stacked charge at WSMR in
Duarte, Ida Alzira Gomes; Tanaka, Greta Merie; Suzuki, Nathalie Mie; Lazzarini, Rosana; Lopes, Andressa Sato de Aquino; Volpini, Beatrice Mussio Fornazier; Castro, Paulo Carrara de
2013-01-01
A retrospective study was carried out between 2006-2011. Six hundred and eighteen patients with suspected allergic contact dermatitis underwent the standard patch test series recommended by the Brazilian Contact Dermatitis Research Group. The aim of our study was to evaluate the variation of positive patch-test results from standard series year by year. The most frequently positive allergens were: nickel sulfate, thimerosal and potassium bichromate. Decrease of positive patch-test results over the years was statistically significant for: lanolin (p=0.01), neomycin (p=0.01) and anthraquinone (p=0.04). A follow-up study should be useful in determining which allergens could be excluded from standard series, as they may represent low sensitization risk.
Dhanani, J A; Barnett, A G; Lipman, J; Reade, M C
2018-05-01
Unnecessary pathology tests performed in intensive care units (ICU) might lead to increased costs of care and potential patient harm due to unnecessary phlebotomy. We hypothesised that a multimodal intervention program could result in a safe and effective reduction in the pathology tests ordered in our ICU. We conducted a single-centre pre- and post-study using multimodal interventions to address commonly ordered routine tests. The study was performed during the same six month period (August to February) over three years: 2012 to 2013 (pre-intervention), 2013 to 2014 (intervention) and 2014 to 2015 (post-intervention). Interventions consisted of staff education, designing new pathology forms, consultant-led pathology test ordering and intensive monitoring for a six-month period. The results of the study showed that there was a net savings of over A$213,000 in the intervention period and A$175,000 in the post-intervention period compared to the pre-intervention period. There was a 28% reduction in the tests performed in the intervention period (P <0.0001 compared to pre-intervention period) and 26% in the post-intervention period (P <0.0001 compared to pre-intervention period). There were no ICU or hospital mortality differences between the groups. There were no significant haemoglobin differences between the groups. A multimodal intervention safely reduced pathology test ordering in the ICU, resulting in substantial cost savings.
ERIC Educational Resources Information Center
New South Wales Dept. of Education, Sydney (Australia).
As part of a series of tests to measure mastery of specific skills in the natural sciences, copies of tests 27 through 38 include: (27) reading a grid plan; (28) identifying common invertebrates; (29) characteristics of invertebrates; (30) identifying elements; (31) using scientific notation part I; (32) classifying minerals; (33) predicting the…
Can Preschool Children Learn Safety Skills? Evaluation of the Safe at Home Curriculum.
ERIC Educational Resources Information Center
Clark, E. Audrey; Simmons, Robert A.
The American Lung Association of Los Angeles County developed the SAFE-AT-HOME curriculum to teach preschool children home safety concepts through early childhood group experiences. This report evaluates the efficacy of the curriculum by testing 2 experimental and 2 control groups of children from 34 preschool classes on fire, water, foreign…
78 FR 9349 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Weight
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-08
... MR incompatibility or the conditions for safe use in an MR environment. Labeling will mitigate the... Amendments of 1976 (Pub. L. 94-295), the Safe Medical Devices Act of 1990 (Pub. L. 101-629), and the Food and...) and nonclinical testing evaluating the compatibility of the device in a MR environment. In addition...
DOT National Transportation Integrated Search
2010-06-11
The purpose of this document is to present the findings of the national evaluation of the deployment of portable traffic monitoring devices (PTMDs) at a variety of locations in North Carolina conducted under the USDOTs SafeTrip-21 Initiative. The ...
DOT National Transportation Integrated Search
2010-06-11
The purpose of this document is to present the findings of the national evaluation of the deployment of portable trafficmonitoring devices (PTMDs) at a variety of locations in North Carolina conducted under the USDOTs SafeTrip-21 Initiative. The N...