Sample records for safety application guide

  1. Toward an Application Guide for Safety Integrity Level Allocation in Railway Systems.

    PubMed

    Ouedraogo, Kiswendsida Abel; Beugin, Julie; El-Koursi, El-Miloudi; Clarhaut, Joffrey; Renaux, Dominique; Lisiecki, Frederic

    2018-02-02

    The work in the article presents the development of an application guide based on feedback and comments stemming from various railway actors on their practices of SIL allocation to railway safety-related functions. The initial generic methodology for SIL allocation has been updated to be applied to railway rolling stock safety-related functions in order to solve the SIL concept application issues. Various actors dealing with railway SIL allocation problems are the intended target of the methodology; its principles will be summarized in this article with a focus on modifications and precisions made in order to establish a practical guide for railway safety authorities. The methodology is based on the flowchart formalism used in CSM (common safety method) European regulation. It starts with the use of quantitative safety requirements, particularly tolerable hazard rates (THR). THR apportioning rules are applied. On the one hand, the rules are related to classical logical combinations of safety-related functions preventing hazard occurrence. On the other hand, to take into account technical conditions (last safety weak link, functional dependencies, technological complexity, etc.), specific rules implicitly used in existing practices are defined for readjusting some THR values. SIL allocation process based on apportioned and validated THR values is finally illustrated through the example of "emergency brake" subsystems. Some specific SIL allocation rules are also defined and illustrated. © 2018 Society for Risk Analysis.

  2. School Chemistry Laboratory Safety Guide

    ERIC Educational Resources Information Center

    Brundage, Patricia; Palassis, John

    2006-01-01

    The guide presents information about ordering, using, storing, and maintaining chemicals in the high school laboratory. The guide also provides information about chemical waste, safety and emergency equipment, assessing chemical hazards, common safety symbols and signs, and fundamental resources relating to chemical safety, such as Material…

  3. Section 8(d) Health Safety Data Reporting User Guide – Primary Support

    EPA Pesticide Factsheets

    This document presents the user guide for the Office of Pollution Prevention and Toxics (OPPT) Section 8(d) Health & Safety Data Reporting application. This document is the user guide for the Primary Support user.

  4. New Jersey Industrial Arts Education Safety Guide.

    ERIC Educational Resources Information Center

    Kobylarz, Joseph D.; Olender, Francis B.

    This guide was developed to assist the teacher in planning, implementing, revising, or improving safety instruction in industrial arts classes in New Jersey, and has as its theme, "Safety Is Everyone's Responsibility." The guide is organized in seven major sections. The first section explains the purpose of the guide, outlines the…

  5. Special Education/Traffic Safety Education. Curriculum Guide.

    ERIC Educational Resources Information Center

    McBrayer, Clyde; Tidwell, Fred

    The curriculum guide for special education students is intended to serve as a supplement to the Washington 1980 State Traffice Safety Education Curriculum Guide. The guide is also correlated with two popular traffic safety texts. Each of the 21 modules contains a goal statement, a list of vocabulary words that might be difficult, a check sheet…

  6. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices

    DOT National Transportation Integrated Search

    2007-01-01

    This guide is a basic reference to assist State Highway Safety Offices (SHSOs) in selecting : effective, science-based traffic safety countermeasures for major highway safety problem areas. : The guide describes major strategies and countermeasures t...

  7. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices

    DOT National Transportation Integrated Search

    2005-01-01

    This guide is a basic reference to assist State Highway Safety Offices (SHSOs) in selecting effective, science-based traffic safety countermeasures for major highway safety problem areas. The guide: describes major strategies and countermeasures that...

  8. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices

    DOT National Transportation Integrated Search

    2009-01-01

    This guide is a basic reference to assist State Highway Safety Offices (SHSOs) in selecting effective, science-based traffic safety countermeasures for major highway safety problem areas. The guide: describes major strategies and countermeasures that...

  9. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices

    DOT National Transportation Integrated Search

    2008-01-01

    This guide is a basic reference to assist State Highway Safety Offices (SHSOs) in selecting effective, science-based traffic safety countermeasures for major highway safety problem areas. The guide: describes major strategies and countermeasures that...

  10. Safety of High Speed Guided Ground Transportation Systems: Work Breakdown Structure

    DOT National Transportation Integrated Search

    1994-11-30

    This report provides a systems approach to the assessment, evaluation and application of high-speed guided ground transportation (HSGGT) safety criteria and : presents one potential methodology by combining a work breakdown structure (WBS) : approach...

  11. Transportation systems safety hazard analysis tool (SafetyHAT) user guide (version 1.0)

    DOT National Transportation Integrated Search

    2014-03-24

    This is a user guide for the transportation system Safety Hazard Analysis Tool (SafetyHAT) Version 1.0. SafetyHAT is a software tool that facilitates System Theoretic Process Analysis (STPA.) This user guide provides instructions on how to download, ...

  12. Safety Action; Traffic and Pedestrian Safety. A Guide for Teachers in the Elementary Schools.

    ERIC Educational Resources Information Center

    Department of Transportation, Washington, DC.

    GRADES OR AGES: Elementary, grades 1-6. SUBJECT MATTER: Safety action, traffic and pedestrian safety. ORGANIZATION AND PHYSICAL APPEARANCE: After introductory material explaining the philosophy of the guide, the elementary school child, characteristics of children as related to safety, and the responsibility of the safety team, the guide has…

  13. Pennsylvania Industrial Arts Safety Guide.

    ERIC Educational Resources Information Center

    Stoudt, John Y., Ed.; And Others

    Safety education information is provided in this guide designed for Pennsylvania industrial arts teachers. Twelve sections and section topics include the following: introduction (policy statement on safety); responsibility (school board and superintendent, principal and/or department head, the teacher); emergency action (primary concerns,…

  14. Guide for Maintaining Pedestrian Facilities for Enhanced Safety.

    DOT National Transportation Integrated Search

    2013-10-01

    A Guide for Maintaining Pedestrian Facilities for Enhanced Safety provides guidance for maintaining pedestrian facilities with the primary goal of increasing safety and mobility. The Guide addresses the needs for pedestrian facility maintenance; comm...

  15. Guide for Science Laboratory Safety.

    ERIC Educational Resources Information Center

    McDermott, John J.

    General and specific safety procedures and recommendations for secondary school science laboratories are provided in this guide. Areas of concern include: (1) chemicals (storage, disposal, toxicity, unstable and incompatible chemicals); (2) microorganisms; (3) plants; (4) animals; (5) electricity; (6) lasers; (7) rockets; (8) eye safety and…

  16. SAFETY GUIDES FOR YOU--IN THE PRIMARY GRADES.

    ERIC Educational Resources Information Center

    WALKER, LUVERNE CRABTREE

    THIS SAFETY INSTRUCTIONAL GUIDE FOR PRIMARY-GRADE TEACHERS PRESENTS NINE DIFFERENT SAFETY UNITS, INCLUDING TRAFFIC SAFETY, PLAYTIME SAFETY, SAFE EATING AND DRINKING HABITS, SAFE CLOTHING, HOME SAFETY, ANIMAL SAFETY, CIVIL DEFENSE SECURITY, AND TESTING SAFETY PRACTICES. EACH UNIT STRESSES THE REASONS FOR ACCENTING SAFETY, WHAT TO KNOW AND DO, AND…

  17. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices, fifth edition, 2010.

    DOT National Transportation Integrated Search

    2010-01-01

    This guide is a basic reference to assist State Highway Safety Offices (SHSOs) in selecting : effective, science-based traffic safety countermeasures for major highway safety problem areas. : The guide: : o describes major strategies and countermeasu...

  18. South Carolina Industrial Arts Safety Guide. Student Section.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This student section of a South Carolina industrial arts safety guide includes guidelines for developing a student safety program and three sections of shop safety practices. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on developing a student safety program. Set forth…

  19. California Guide to Traffic Safety Education.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    The guide proposes an elementary through high school program encompassing many aspects of traffic safety. Chapter 1 presents definitions, instructional goals, behavioral objectives, and K-6 traffic safety concepts coupled with student performance indicators. Various elements of program administration are covered in Chapter 2. Chapter 3 includes…

  20. Industrial Education Safety Guide.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    California is one of the few states in which school districts have a legal responsibility for accidents involving students while they are participating in assigned school activities. This guide was prepared to help school administrators and teachers evaluate their safety instruction programs and industrial education facilities in accordance with…

  1. Industrial Arts Curriculum Guide for Safety.

    ERIC Educational Resources Information Center

    Connecticut State Dept. of Education, Hartford. Div. of Vocational Education.

    This guide is intended to draw attention to the necessity for safety education in every aspect of industrial arts and to provide resources for upgrading and improving safety instruction in the classroom. It also can be used for inservice training of industrial art teachers and for undergraduate teacher education in Connecticut. Introductory…

  2. Electronics. Module 1: Electronic Safety. Instructor's Guide.

    ERIC Educational Resources Information Center

    Tharp, Bill

    This guide contains instructor's materials for a three-unit secondary school course on electronic safety. The units are shop safety principles, hand tools, and alternating current safety and protection devices. The document begins with advice on its use and a cross-referenced table of instructional materials that show which materials in the guide…

  3. An Illustrated Guide to Electrical Safety. Revised

    ERIC Educational Resources Information Center

    Occupational Safety and Health Administration, Washington, DC.

    This guide was developed to serve as a supplement to the Occupational Safety and Health Administration's (OSHA) Electrical Safety Standards, 29 CFR 1910, Subpart S, Electrical. It is designed for use by a variety of people (layman, worker, employer, compliance safety and health officer, union official, educator, and others) in training, education,…

  4. Laboratory Safety Guide for Arkansas K-12 Schools.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock.

    This document presents laboratory safety rules for Arkansas K-12 schools which were developed by the Arkansas Science Teachers Association (ASTA) and the Arkansas Department of Education (ADE). Contents include: (1) "Laboratory Safety Guide for Arkansas K-12 Schools"; (2) "Safety Considerations"; (3) "Safety Standards for Science Laboratories";…

  5. K-9 Traffic Safety Resource Curriculum. Level C. Professional Guide.

    ERIC Educational Resources Information Center

    Governor's Highway Safety Program Office, Raleigh, NC.

    One of four curriculum guides designed to aid teachers of grades K-9 in implementing a balanced, dynamic traffic safety program, this level C guide contains materials for teachers of grades 4-6. Four units in pedestrian, bicycle, school bus, and passenger safety are presented, and minicycle and optional farm vehicle safety units are introduced.…

  6. Watch Out! A Teacher's Guide to Traffic Safety.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Div. of Curriculum and Instruction.

    This guide provides teachers with activities that can initiate an awareness of the New York city-wide traffic safety campaign and reinforce safety education. It contains the following: (1) background information on safety rules for teachers; (2) curriculum topics that can include traffic safety issues; (3) class- and school-wide activities for…

  7. Driver and Traffic Safety Education Curriculum Guide.

    ERIC Educational Resources Information Center

    Massachusetts State Dept. of Education, Boston. Bureau of Elementary and Secondary Education.

    Materials contained in this Massachusetts curriculum guide are based on concepts and procedures developed by the Highway Users Federation for Safety and Mobility. The guide examines the philosophy of driver education, discusses such legal aspects as certification of students and teachers, presents a comprehensive classroom and behind-the-wheel…

  8. Industrial Arts Safety Guide. Thai. Bilingual Education Resource Series.

    ERIC Educational Resources Information Center

    Seattle School District 1, WA.

    Designed for use in bilingual education programs, this industrial arts safety guide presents guidelines for developing a student safety program and three sections of shop safety practices in both English and Thai. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on…

  9. Industrial Arts Safety Guide. Japanese. Bilingual Education Resource Series.

    ERIC Educational Resources Information Center

    Seattle School District 1, WA.

    Designed for use in bilingual education programs, this industrial arts safety guide presents guidelines for developing a student safety program and three sections of shop safety practice in both English and Japanese. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on…

  10. Industrial Arts Safety Guide. Cambodian. Bilingual Education Resource Series.

    ERIC Educational Resources Information Center

    Seattle School District 1, WA.

    Designed for use in bilingual education programs, this industrial arts safety guide includes guidelines for developing a student safety program and three sections of shop safety practices in both English and Cambodian. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on…

  11. Industrial Arts Safety Guide. Korean. Bilingual Education Resource Series.

    ERIC Educational Resources Information Center

    Seattle School District 1, WA.

    Designed for use in bilingual education programs, this industrial arts safety guide presents guidelines for developing a student safety program and three sections of shop safety practices in both English and Korean. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on…

  12. Industrial Arts Safety Guide. Ilokano. Bilingual Education Resource Series.

    ERIC Educational Resources Information Center

    Seattle School District 1, WA.

    Designed for use in bilingual education programs, this industrial arts safety guide presents guidelines for developing a student safety program and three sections of shop safety practices in both English and Ilokano. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on…

  13. Industrial Arts Safety Guide. Chinese. Bilingual Education Resource Series.

    ERIC Educational Resources Information Center

    Seattle School District 1, WA.

    Designed for use in bilingual education programs, this industrial arts safety guide presents guidelines for developing a student safety program and three sections of shop safety practices in both English and Chinese. Safety program format, safety committees, safety inspection, and student accident investigation are discussed in the section on…

  14. Safety in the Science Laboratory, A Guide.

    ERIC Educational Resources Information Center

    Christian, Floyd T.

    The bulletin was prepared as a general guide to encourage the use of safe practices in science laboratories in Florida schools. The guide begins with an outline of recommended emergency procedures. Chapter I discusses the importance of safety in the science program. Chapter II discusses handling and storage of equipment, and designing laboratory…

  15. Pennsylvania Industrial Arts Safety Guide. Second Edition.

    ERIC Educational Resources Information Center

    Graham, Charles D., Ed.

    Intended to alert industrial arts teachers, teacher educators, school administrators, and industrial arts supervisors to the importance of a strong safety program, this guide provides the instructional resources for instituting safety instruction in the public schools, for the inservice training of industrial arts teachers, and for the education…

  16. Health and Safety Guide for K-12 Schools in Washington.

    ERIC Educational Resources Information Center

    Kerns, James T.; Ellis, Richard E.

    This guide's primary focus is to recommend good health and safety practices to helpensure safer schools in Washington state. Some of the safety practices that are recommended affect school operationand maintenance, repairs and minor construction, as well as the school's administrative organization and lines of communication. The guide also focuses…

  17. Oklahoma Curriculum Guide for Teaching Safety Education.

    ERIC Educational Resources Information Center

    Oklahoma Curriculum Improvement Commission, Oklahoma City.

    Developed by classroom teachers, university professors, and personnel from the Oklahoma State Department of Education, this guide is an effort to assist teachers in locating and utilizing safety materials as well as to assist them in developing well-balanced safety programs for the children and young people in the state. The preschool and…

  18. Oakland County Science Safety Series: Reference Guide for Elementary Science.

    ERIC Educational Resources Information Center

    Crowder, Betty Pogue; And Others

    This reference guide is designed to organize and suggest acceptable practices and procedures for dealing with safety in elementary science instruction. It is intended as a reference for teachers, administrators, and other school staff in planning for science activities and in making daily safety decisions. Topics covered in the guide include: (1)…

  19. Apply Pesticides Correctly, A Guide for Commercial Applicators: Seed Treatment.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide contains basic information to meet specific standards for pesticide applicators. The text is concerned with the types of seeds that require chemical protection against pests. Methods of treatment and labeling requirements for such seeds as rye, wheat, soybeans, peas, and grass hybrids are discussed. Safety and environmental precautions…

  20. The Development of a Vocational Safety Guide for Missouri's Practitioners. Final Report.

    ERIC Educational Resources Information Center

    Dyrenfurth, Michael; Linhardt, Richard

    A project was conducted to develop a comprehensive vocational education safety guide for local administrators and teachers. To generate the guide, the following steps were completed: (1) a review of key related research, literature, and federal and state legislation, including vocational safety guides from 18 states; reference material from the…

  1. AquaSMART: Water & Boating Safety, Grades K-2. Teacher's Guide.

    ERIC Educational Resources Information Center

    Texas State Dept. of Parks and Wildlife, Austin.

    This teacher's guide accompanies a program designed to teach water and boating safety to students in grades K-2. The written curriculum accompanies a video, AquaSMART K-2. The theme of the curriculum is AquaSMART. To become AquaSMART, students must learn 10 basic lessons for water and boating safety. The teacher's guide begins with an overview of…

  2. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide

    PubMed Central

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Introduction Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. Methods The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Results Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. Discussion This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety. PMID:26406893

  3. Field Test of the World Health Organization Multi-Professional Patient Safety Curriculum Guide.

    PubMed

    Farley, Donna; Zheng, Hao; Rousi, Eirini; Leotsakos, Agnès

    2015-01-01

    Although the importance of training in patient safety has been acknowledged for over a decade, it remains under-utilized and under-valued in most countries. WHO developed the Multi-professional Patient Safety Curriculum Guide to provide schools with the requirements and tools for incorporating patient safety in education. It was field tested with 12 participating schools across the six WHO regions, to assess its effectiveness for teaching patient safety to undergraduate and graduate students in a global variety of settings. The evaluation used a combined prospective/retrospective design to generate formative information on the experiences of working with the Guide and summative information on the impacts of the Guide. Using stakeholder interviews and student surveys, data were gathered from each participating school at three times: the start of the field test (baseline), soon after each school started teaching, and soon after each school finished teaching. Stakeholders interviewed were strongly positive about the Guide, noting that it emphasized universally important patient safety topics, was culturally appropriate for their countries, and gave credibility and created a focus on patient safety at their schools. Student perceptions and attitudes regarding patient safety improved substantially during the field test, and their knowledge of the topics they were taught doubled, from 10.7% to 20.8% of correct answers on the student survey. This evaluation documented the effectiveness of the Curriculum Guide, for both ease of use by schools and its impacts on improving the patient safety knowledge of healthcare students. WHO should be well positioned to refine the contents of the Guide and move forward in encouraging broader use of the Guide globally for teaching patient safety.

  4. Protect Their Eyes: An Eye Safety Guide for the Classroom.

    ERIC Educational Resources Information Center

    Ohio Society to Prevent Blindness, Columbus.

    This guide provides information on eye safety and aids educators, administrators, and supervisors in the development and implementation of eye safety programs. The American National Standards Institute (AMSI) requirements for both street and safety glasses; essential eyewear for safety in hazardous areas; the National Society to Prevent…

  5. Improving safety on rural local and tribal roads site safety analysis - user guide #1.

    DOT National Transportation Integrated Search

    2014-08-01

    This User Guide presents an example of how rural local and Tribal practitioners can study conditions at a preselected site. It demonstrates the step-by-step safety analysis process presented in Improving Safety on Rural Local and Tribal Roads Saf...

  6. Department of Energy Construction Safety Reference Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1993-09-01

    DOE has adopted the Occupational Safety and Health Administration (OSHA) regulations Title 29 Code of Federal Regulations (CFR) 1926 ``Safety and Health Regulations for Construction,`` and related parts of 29 CFR 1910, ``Occupational Safety and Health Standards.`` This nonmandatory reference guide is based on these OSHA regulations and, where appropriate, incorporates additional standards, codes, directives, and work practices that are recognized and accepted by DOE and the construction industry. It covers excavation, scaffolding, electricity, fire, signs/barricades, cranes/hoists/conveyors, hand and power tools, concrete/masonry, stairways/ladders, welding/cutting, motor vehicles/mechanical equipment, demolition, materials, blasting, steel erection, etc.

  7. South Carolina Industrial Arts Safety Guide. Administrator and Instructor Section.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia.

    This administrator and instructor section of a South Carolina industrial arts safety guide includes sections on responsibility for school safety, safety programming for the teacher, emergency action, suggested forms and outlines, and facility design and layout. School board and superintendent, administrator, and teacher responsibilities for school…

  8. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices : eighth edition : 2015

    DOT National Transportation Integrated Search

    2015-11-01

    The guide is a basic reference to assist State Highway Safety Offices in selecting effective, evidence- based : countermeasures for traffic safety problem areas. These areas include: : - Alcohol-and Drug-Impaired Driving; : - Seat Belts and Child Res...

  9. Countermeasures that work : a highway safety countermeasure guide for state highway safety offices : seventh edition : 2013

    DOT National Transportation Integrated Search

    2013-04-01

    The guide is a basic reference to assist State Highway Safety Offices (SHSOs) in selecting effective, evidence-based countermeasures for traffic safety problem areas. These areas include: : - Alcohol-Impaired and Drugged Driving; : - Seat Belts and C...

  10. Estimation of adhesive bond strength in laminated safety glass using guided mechanical waves

    NASA Astrophysics Data System (ADS)

    Huo, Shihong

    Laminated safety glass is used in the automobile industry and in architectural applications. Laminated safety glass consists of a plastic interlayer, such as a layer of poly vinyl butyral (PVB) or Butacite, surrounded by two adjacent glass plates. The glass can be float glass, plate glass, tempered glass, or sheet glass, and the plastic interlayer is made of a viscoelastic material with relatively high damping. The level of adhesive bond strength between the plastic interlayer and the two adjacent glass plates has a significant role in the penetration resistance against flying objects and is a critical parameter towards ensuring the proper performance of safety glass. Therefore, estimation and control of adhesive bond levels in laminated safety glass is a critical issue. There are several destructive testing procedures used to quantify the adhesion level in laminated safety glass. These tests include the tension test, the peel test, the impact test, and the pummel test. All these tests have drawbacks including the pummel test method, which has been the most widely used in industry for over 80 years. The primary drawbacks of the pummel test method are that it is destructive and subjective (i.e., involves individual human judgment), which precludes this method for use as an on-line test method for quality control. Consequently, a quantitative nondestructive testing method to evaluate adhesion levels would be an asset to the laminated safety glass industry. In this study, adhesion levels in laminated safety glass samples, i.e., windshields, have been assessed using the guided mechanical wave method. To study the adhesive bond strength analytically, the imperfect interfaces between the plastic interlayer and the two adjacent glass plates in laminated safety glass are modeled using a bed of longitudinal and shear springs, and their stiffness characteristics are estimated using fracture mechanics and atomic force microscopy (AFM) surface measurements. The atomic force

  11. Oakland County Science Safety Series: Reference Guide for Biology.

    ERIC Educational Resources Information Center

    Bury, Dan; And Others

    This reference guide is designed to organize and suggest acceptable practices and procedures for dealing with safety in the area of biology instruction. It is intended as a reference for teachers, administrators, and other school staff in planning for science activities and in making daily safety decisions. Discussions deal with responsibility for…

  12. Safety Guide for Health Occupations Programs.

    ERIC Educational Resources Information Center

    Illinois State Board of Vocational Education and Rehabilitation, Springfield. Div. of Vocational and Technical Education.

    The handbook is intended to be utilized by health occupations teachers as supplementary instructional materials for a unit on safety. The document contains general safety rules applicable to hospitals and other health care institutions. Outlined are general rules for fire safety and office and clerical safety and more specific rules for the…

  13. Fire Safety. Managing School Facilities, Guide 6.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  14. Pedestrian Safety: Injury Control Curriculum Guide (For K - 3rd Grade). Second Edition.

    ERIC Educational Resources Information Center

    Wooner, Rosestelle B., Ed.

    This curriculum guide attempts to help the early childhood teacher show children how to incorporate safety precautions into daily life. Good safety practices can prevent the death or injury of young children by automobile, truck, bus, pedestrian, bicycle, and tricycle accidents. The guide focuses on student involvement in the learning process and…

  15. Pedestrian facilities users guide : providing safety and mobility

    DOT National Transportation Integrated Search

    2002-03-01

    The Guide provides information on how to identify safety and mobility needs of pedestrians within roadway rights-of-way. Chapter 1 provides an overview of the creation of a walkable environment. Chepter 2 describes basic pedestrian crash trends and t...

  16. Guide to active vaccine safety surveillance: Report of CIOMS working group on vaccine safety - executive summary.

    PubMed

    Heininger, U; Holm, K; Caplanusi, I; Bailey, S R

    2017-07-13

    In 2013, the Council for International Organizations of Medical Sciences (CIOMS) created a Working Group on Vaccine Safety (WG) to address unmet needs in the area of vaccine pharmacovigilance. Generating reliable data about specific vaccine safety concerns is becoming a priority due to recent progress in the development and deployment of new vaccines of global importance, as well as novel vaccines targeting diseases specifically endemic to many resource-limited countries (RLCs), e.g. malaria, dengue. The WG created a Guide to Active Vaccine Safety Surveillance (AVSS) to assist national regulatory authorities and national immunization program officers in RLCs in determining the best course of action with regards to non-routine pharmacovigilance activities, when confronted with a launch of a new vaccine or a vaccine that is new to their country. Here we summarize the results of the WG, further detailed in the Guide, which for the first time provides a structured approach to identifying and analyzing specific vaccines safety knowledge gaps, while considering all available sources of information, in order to determine whether AVSS is an appropriate solution. If AVSS is confirmed as being the appropriate tool, the Guide provides additional essential information on AVSS, a detailed overview of common types of AVSS and practical implementation considerations. It also provides a framework for a well-constructed and informative AVSS when needed, thus aiming to ensure the best possible safety of immunization in this new landscape. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Health and Safety Guide for K-12 Schools in Washington.

    ERIC Educational Resources Information Center

    Ellis, Richard E.; Kerns, James T.; Currie, Michael

    This guide, which can be used as a school self-inspection tool, is designed to help Washington's K-12 public schools prevent and reduce injuries and illnesses by focusing on good health and safety practices. The guide also focuses on practices that can be undertaken during the design, construction, renovation, operation, maintenance, or inspection…

  18. Safety & Health. Resource Guide for Occupational/Technology Education.

    ERIC Educational Resources Information Center

    Kirk, Albert S., Ed.

    This guide is intended to alert occupational/technology teachers, teacher educators, school administrators, and industrial education supervisors to the need and importance of a strong and active safety program. Responsibilities are detailed for all individuals involved. Teacher liability is addressed. A section on emergency procedures covers…

  19. AquaSMART: Water & Boating Safety, Grades 3-5. Teacher's Guide.

    ERIC Educational Resources Information Center

    Texas State Dept. of Parks and Wildlife, Austin.

    This teacher's guide accompanies a program designed to teach water and boating safety to students in grades 3-5. The written curriculum accompanies a video, AquaSMART 3-5. The theme of the curriculum is AquaSMART. To become AquaSMART, students must learn 10 basic lessons for water and boating safety. The written curriculum begins with an overview…

  20. Wisconsin Driver and Traffic Safety Education: Teacher Preparation Guide. Bulletin Number 7221.

    ERIC Educational Resources Information Center

    Wisconsin Univ., Whitewater.

    This guide identifies the minimum competencies necessary to teach and administer a high school driver and traffic safety education (DTSE) program and provides curricular suggestions for the University of Wisconsin System teacher preparation program. Course descriptions are listed for the following areas: general safety, traffic safety education,…

  1. The art of appropriate evaluation : a guide for highway safety program managers

    DOT National Transportation Integrated Search

    2008-08-01

    The guide, updated from its original release in 1999, is intended for project managers who will oversee the evaluation of traffic safety programs. It describes the benefits of evaluation and provides an overview of the steps involved. The guide inclu...

  2. The art of appropriate evaluation : a guide for highway safety program managers

    DOT National Transportation Integrated Search

    2008-12-01

    The guide, updated from its original release in 1999, is intended for project managers who will oversee the evaluation of traffic safety programs. It describes the benefits of evaluation and provides an overview of the steps involved. The guide inclu...

  3. Implementation guide for monitoring work zone safety and mobility impacts

    DOT National Transportation Integrated Search

    2009-01-01

    This implementation guide describes the conceptual framework, data requirements, and computational procedures for determining the safety and mobility impacts of work zones in Texas. Researchers designed the framework and procedures to assist district...

  4. Guiding principles of safety as a basis for developing a pharmaceutical safety culture.

    PubMed

    Edwards, Brian; Olsen, Axel K; Whalen, Matthew D; Gold, Marla J

    2007-05-01

    Despite the best efforts of industry and regulatory authorities, the trust of society in the process of medicine development and communication of pharmaceutical risk has ebbed away. In response the US government has called for a culture of compliance while the EU regulators talk of a 'culture of scientific excellence'. However, one of the fundamental problems hindering progress to rebuilding trust based on a pharmaceutical safety culture is the lack of agreement and transparency between all stakeholders as to what is meant by a 'Safety of Medicines'. For that reason, we propose 'Guiding Principles of Safety for Pharmaceuticals' are developed analogous to the way that Chemical Safety has been tackled. A logical starting point would be to examine the Principles outlined by the US Institute of Medicine although we acknowledge that these Principles require further extensive debate and definition. Nevertheless, the Principles should take centre stage in the reform of pharmaceutical development required to restore society's trust.

  5. Nutrition, Health, and Safety for Child Caregivers: Instructor's Guide.

    ERIC Educational Resources Information Center

    Texas Tech Univ., Lubbock. Home Economics Instructional Materials Center.

    This guide for postsecondary child development instructors is intended for use in courses on nutrition, health, and safety in a child care setting. The materials are most effective when coordinated with carefully selected textbooks. Access to a quality care center for laboratory work is essential. An introduction describes the instructor's guide…

  6. ASHRAE's new Chiller Heat Recovery Application Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dorgan, C.B.; Dorgan, C.E.

    2000-07-01

    The new Chiller Heat Recovery Application Guide, published by the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE), provides a comprehensive reference manual on the options available for chiller heat recovery. The information in the guide will assist engineers, owners, and system operators in evaluating the potential of integrating chiller heat recovery into their cooling and heating systems. The primary focus is on new construction and applications where a chiller is being replaced due to inefficiency, high operating and maintenance (O and M) costs, or elimination of refrigerants containing ozone-depleting chemicals known as CFC/HCFCs. While chiller systems for commercialmore » buildings are the primary focus of the guide, the information and procedures also apply to industrial heat pumps. The function of this paper is to highlight key information contained in the guide, including the major benefits of chiller heat recovery, primary candidates, and application procedures. A description of the guide's general format and contents is also provided.« less

  7. Product Safety, It's No Accident. A Consumer Product Safety Monthly Planning Guide for Community Organizations.

    ERIC Educational Resources Information Center

    Consumer Product Safety Commission, Washington, DC.

    A consumer product safety monthly planning guide for community organizations is provided. The material is organized into suggested monthly topics with seasonal emphasis. Each section highlights selected information about how to identify potential hazards associated with categories of products. Each section also includes recommendaitons of ways to…

  8. COL Application Content Guide for HTGRs: Revision to RG 1.206, Part 1 - Status Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wayne Moe

    2012-08-01

    A combined license (COL) application is required by the Nuclear Regulatory Commission (NRC) for all proposed nuclear plants. The information requirements for a COL application are set forth in 10 CFR 52.79, “Contents of Applications; Technical Information in Final Safety Analysis Report.” An applicant for a modular high temperature gas-cooled reactor (HTGR) must develop and submit for NRC review and approval a COL application which conforms to these requirements. The technical information necessary to allow NRC staff to evaluate a COL application and resolve all safety issues related to a proposed nuclear plant is detailed and comprehensive. To this, Regulatorymore » Guide (RG) 1.206, “Combined License Applications for Nuclear Power Plants” (LWR Edition), was developed to assist light water reactor (LWR) applicants in incorporating and effectively formatting required information for COL application review (Ref. 1). However, the guidance prescribed in RG 1.206 presumes a LWR design proposal consistent with the systems and functions associated with large LWR power plants currently operating under NRC license.« less

  9. California Guide for Pedestrian Safety Education. Volumes I-III.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    This guide is designed to serve as the basis for a pedestrian safety education program for pupils in kindergarten through grade two. The basic printed materials for use in the program are provided in three volumes, each of which is intended for a different audience. Volume I, directed to school administrators and teachers, contains information for…

  10. Tornadoes: Nature's Most Violent Storms. A Preparedness Guide Including Safety Information for Schools.

    ERIC Educational Resources Information Center

    American National Red Cross, Washington, DC.

    This preparedness guide explains and describes tornadoes, and includes safety information for schools. A tornado is defined as a violently rotating column of air extending from a thunderstorm to the ground. The guide explains the cause of tornadoes, provides diagrams of how they form, describes variations of tornadoes, and classifies tornadoes by…

  11. Development of a Mapped Diabetes Community Program Guide for a Safety Net Population

    PubMed Central

    Zallman, Leah; Ibekwe, Lynn; Thompson, Jennifer W.; Ross-Degnan, Dennis; Oken, Emily

    2014-01-01

    Purpose Enhancing linkages between patients and community programs is increasingly recognized as a method for improving physical activity, nutrition and weight management. Although interactive mapped community program guides may be beneficial, there remains a dearth of articles that describe the processes and practicalities of creating such guides. This article describes the development of an interactive, web-based mapped community program guide at a safety net institution and the lessons learned from that process. Conclusions This project demonstrated the feasibility of creating two maps – a program guide and a population health map. It also revealed some key challenges and lessons for future work in this area, particularly within safety-net institutions. Our work underscores the need for developing partnerships outside of the health care system and the importance of employing community-based participatory methods. In addition to facilitating improvements in individual wellness, mapping community programs also has the potential to improve population health management by healthcare delivery systems such as hospitals, health centers, or public health systems, including city and state departments of health. PMID:24752180

  12. Electrical safety Q&A. A reference guide for the clinical engineer.

    PubMed

    2005-02-01

    This guide, which ECRI developed to answer the electrical safety questions most frequently asked by member hospitals, features practical advice for addressing electrical safety concerns in the healthcare environment. Questions addressed include: STANDARDS AND APPROVALS: What electrical safety standards apply? How do NFPA 99 and IEC 60601-1 differ? What organizations approve medical devices? LEAKAGE CURRENT LIMITS AND TESTING: How are leakage current limits established? What limits apply to equipment used in the hospital? And how should the limits be applied in special cases, such as the use of PCs in the patient care area or equipment used in the clinical laboratory? ISOLATED POWER: What are its advantages and disadvantages, and is isolated power needed in the operating room? Other topics addressed include double insulation, ground-fault circuit interrupters (GFCIs), and requirements for medical devices used in the home. Supplementary articles discuss acceptable alternatives to UL listing, the use of Hospital Grade plugs, the limitations of leakage current testing of devices connected to isolated power systems, and the debate about whether to designate ORs as wet locations. Experienced clinical engineers should find this guide to be a handy reference, while those new to the field should find it to be a helpful educational resource.

  13. Connected vehicle applications : safety.

    DOT National Transportation Integrated Search

    2016-01-01

    Connected vehicle safety applications are designed to increase situational awareness : and reduce or eliminate crashes through vehicle-to-infrastructure, vehicle-to-vehicle, : and vehicle-to-pedestrian data transmissions. Applications support advisor...

  14. Connected vehicle applications : safety.

    DOT National Transportation Integrated Search

    2016-01-01

    Connected vehicle safety applications are designed to increase situational awareness and reduce or eliminate crashes through vehicle-to-infrastructure, vehicle-to-vehicle, and vehicle-to-pedestrian data transmissions. Applications support advisories ...

  15. Guiding principles for the implementation of non-animal safety assessment approaches for cosmetics: skin sensitisation.

    PubMed

    Goebel, Carsten; Aeby, Pierre; Ade, Nadège; Alépée, Nathalie; Aptula, Aynur; Araki, Daisuke; Dufour, Eric; Gilmour, Nicola; Hibatallah, Jalila; Keller, Detlef; Kern, Petra; Kirst, Annette; Marrec-Fairley, Monique; Maxwell, Gavin; Rowland, Joanna; Safford, Bob; Schellauf, Florian; Schepky, Andreas; Seaman, Chris; Teichert, Thomas; Tessier, Nicolas; Teissier, Silvia; Weltzien, Hans Ulrich; Winkler, Petra; Scheel, Julia

    2012-06-01

    Characterisation of skin sensitisation potential is a key endpoint for the safety assessment of cosmetic ingredients especially when significant dermal exposure to an ingredient is expected. At present the mouse local lymph node assay (LLNA) remains the 'gold standard' test method for this purpose however non-animal test methods are under development that aim to replace the need for new animal test data. COLIPA (the European Cosmetics Association) funds an extensive programme of skin sensitisation research, method development and method evaluation and helped coordinate the early evaluation of the three test methods currently undergoing pre-validation. In May 2010, a COLIPA scientific meeting was held to analyse to what extent skin sensitisation safety assessments for cosmetic ingredients can be made in the absence of animal data. In order to propose guiding principles for the application and further development of non-animal safety assessment strategies it was evaluated how and when non-animal test methods, predictions based on physico-chemical properties (including in silico tools), threshold concepts and weight-of-evidence based hazard characterisation could be used to enable safety decisions. Generation and assessment of potency information from alternative tools which at present is predominantly derived from the LLNA is considered the future key research area. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Curriculum and Evaluation Guide for Safety Education Programs. Research and Evaluation Report Series No. 40.00.

    ERIC Educational Resources Information Center

    Lowry, Carlee S.

    Designed to assist Bureau of Indian Affairs school officials in the identification of safety education program needs, this evaluation guide focuses upon the basic operational components in a safety education program. The means for establishing an evaluation design for safety education are presented via a flexible model appropriate for most…

  17. The image-guided surgery toolkit IGSTK: an open source C++ software toolkit.

    PubMed

    Enquobahrie, Andinet; Cheng, Patrick; Gary, Kevin; Ibanez, Luis; Gobbi, David; Lindseth, Frank; Yaniv, Ziv; Aylward, Stephen; Jomier, Julien; Cleary, Kevin

    2007-11-01

    This paper presents an overview of the image-guided surgery toolkit (IGSTK). IGSTK is an open source C++ software library that provides the basic components needed to develop image-guided surgery applications. It is intended for fast prototyping and development of image-guided surgery applications. The toolkit was developed through a collaboration between academic and industry partners. Because IGSTK was designed for safety-critical applications, the development team has adopted lightweight software processes that emphasizes safety and robustness while, at the same time, supporting geographically separated developers. A software process that is philosophically similar to agile software methods was adopted emphasizing iterative, incremental, and test-driven development principles. The guiding principle in the architecture design of IGSTK is patient safety. The IGSTK team implemented a component-based architecture and used state machine software design methodologies to improve the reliability and safety of the components. Every IGSTK component has a well-defined set of features that are governed by state machines. The state machine ensures that the component is always in a valid state and that all state transitions are valid and meaningful. Realizing that the continued success and viability of an open source toolkit depends on a strong user community, the IGSTK team is following several key strategies to build an active user community. These include maintaining a users and developers' mailing list, providing documentation (application programming interface reference document and book), presenting demonstration applications, and delivering tutorial sessions at relevant scientific conferences.

  18. Charged Up for Fire Safety. Fifth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fifth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fifth grade students, its objectives include: (1) exploring heating equipment safety, (2) analyzing the impact of fire on the outdoor environment and methods to reduce that impact, (3) developing…

  19. Connected vehicle application : safety.

    DOT National Transportation Integrated Search

    2015-01-01

    Connected vehicle safety applications are designed to increase situational awareness : and reduce or eliminate crashes through vehicle-to-infrastructure (V2I), vehicle-to-vehicle (V2V), and vehicle-to-pedestrian (V2P) data transmissions. Applications...

  20. 29 CFR 1924.1 - Applicable safety standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Applicable safety standards. 1924.1 Section 1924.1 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY STANDARDS APPLICABLE TO WORKSHOPS AND REHABILITATION FACILITIES ASSISTED BY GRANTS § 1924...

  1. San Jose Unified School District Health & Safety Guide for Facilities and Construction.

    ERIC Educational Resources Information Center

    2001

    This guide from the San Jose Unified School District describes recommended procedures to promote and maintain a healthy and safe school environment during maintenance, modernization, or construction. Guidelines are presented in the following areas: (1) construction safety; (2) communication; (3) material selection; (4) heating, ventilation, and…

  2. Safety Education. A Guide To Help Prevent Accidents Associated with the Home, Student Transportation, Disasters, Pedestrians, Passengers, Fires, Consumerism, Recreation.

    ERIC Educational Resources Information Center

    Texas Education Agency, Austin.

    This teacher's guide presents 10 instructional units for one portion of the Texas-approved course in driver and safety education. The units cover the following topics: what is safety?; accident causation and prevention; home safety; student transportation safety; disasters; pedestrian safety; passenger safety; fire safety; consumer safety; and…

  3. MR-guided interstitial laser thermotherapy of colorectal liver metastases: efficiency, safety and patient survival.

    PubMed

    Pech, M; Wieners, G; Freund, T; Dudeck, O; Fischbach, F; Ricke, J; Seemann, M D

    2007-04-26

    Evaluation of MR-guided interstitial laser thermotherapy (ILT) of colorectal liver metastases under consideration of efficacy, safety and patient survival. Sixty-six inoperable patients with a total of 117 colorectal liver metastases were treated with MR-guided laser therapy in 96 sessions. 40.9% of patients presented metastases from rectum carcinoma, 30.3% from sigmoid carcinoma and 28.8% from colon carcinoma. Inclusion criteria were < or =5 metastases < or =5 cm in greatest diameter and no extrahepatic tumor spread. Internally water-cooled 9F power-laser-applicators were placed under CT-fluoroscopy. For MR-guided ILT, a 1064 nm Nd-YAG-lasers with a beam divider with multi applicator technique was used. The energy applied was 10 watt per centimeter diffusor length, with the diffusor length ranging from 20 to 40 mm. The mean duration of the energy application was 23 minutes (range: 15 - 37 minutes). The endpoint of the laser ablation was defined as the absence of hyperintense tumor tissue in the continuously monitored T2-w fat saturated gradient-echo sequences. Follow-up included contrast-enhanced MRI using T1- and T2-weighted spin-echo and gradient-echo sequences every three months after treatment. Survival times were calculated using the Kaplan-Meier method. The median follow-up was 8.7 months (mean 11.8; standard deviation 9.9; range 1 to 36). The overall median progression free survival was 6.1 months (range, 0.3 to 27+ months). Median survival was 23 months (95% CI, 17-29 months). The rate of major complications was 2.1% (n = 2) and peri-procedural mortality (30 days) was 3% (n = 2). After 3, 6, 9, and 12 months, local tumor control was 98.3%, 91.4%, 76.1%, and 69.4%, respectively. In no patient metastatic deposits along the catheter access route were found. In patients with colorectal liver metastases, interstitial laser thermotherapy is an effective and safe therapeutic option and therefore suitable not only in palliative situations.

  4. Guide to School Health and Safety Committees: How To Promote Child and Adult Environmental Health Protection.

    ERIC Educational Resources Information Center

    Healthy Schools Network, Inc., Albany, NY.

    This guide discusses the importance of having school health and safety committees, describes New York law creating these committees, explores their responsibilities and recommended actions, and examines what committees can do to efficiently meet their goals. The guide details school walk-throughs as the best way to learn about a school, including…

  5. It's No Accident: A Consumer Product Safety Education Curriculum Resource Guide for Teachers of Grades 3 through 6.

    ERIC Educational Resources Information Center

    Consumer Product Safety Commission, Washington, DC.

    This guide for teachers contains product safety information appropriate for young children and suggests learning activities for third through sixth graders. Activities encourage children to examine their home environments for safety hazards and to share this information with family and friends. Unit 1 introduces five basic safety concepts upon…

  6. Application Processing, 2003-2004. EDExpress Training. Participant Guide.

    ERIC Educational Resources Information Center

    Office of Student Financial Assistance (ED), Washington, DC.

    This participant guide contains training materials for processing applications for student financial aid under the EDExpress system. Representatives of institutions of higher education receive training in the use of EDExpress software that allows the school to manage student financial aid records. The guide contains these sessions: (1) welcome and…

  7. The SAFER guides: empowering organizations to improve the safety and effectiveness of electronic health records.

    PubMed

    Sittig, Dean F; Ash, Joan S; Singh, Hardeep

    2014-05-01

    Electronic health records (EHRs) have potential to improve quality and safety of healthcare. However, EHR users have experienced safety concerns from EHR design and usability features that are not optimally adapted for the complex work flow of real-world practice. Few strategies exist to address unintended consequences from implementation of EHRs and other health information technologies. We propose that organizations equipped with EHRs should consider the strategy of "proactive risk assessment" of their EHR-enabled healthcare system to identify and address EHR-related safety concerns. In this paper, we describe the conceptual underpinning of an EHR-related self-assessment strategy to provide institutions a foundation upon which they could build their safety efforts. With support from the Office of the National Coordinator for Health Information Technology (ONC), we used a rigorous, iterative process to develop a set of 9 self-assessment tools to optimize the safety and safe use of EHRs. These tools, referred to as the Safety Assurance Factors for EHR Resilience (SAFER) guides, could be used to self-assess safety and effectiveness of EHR implementations, identify specific areas of vulnerability, and create solutions and culture change to mitigate risks. A variety of audiences could conduct these assessments, including frontline clinicians or care teams in different practices, or clinical, quality, or administrative leaders within larger institutions. The guides use a multifaceted systems-based approach to assess risk and empower organizations to work with internal or external stakeholders (eg, EHR developers) on optimizing EHR functionality and using EHRs to drive improvements in the quality and safety of healthcare.

  8. Business Financial Applications. Curriculum Guide. Simulations. Test Bank.

    ERIC Educational Resources Information Center

    Massey, Ray Nell; Patton, Jan

    This business financial applications document combines the curriculum guide, simulations, and the test bank for the 1-semester course. The guide provides students with an overview of the banking industry used for entry-level positions or advancement into an occupationally specific course. It begins with a course description, suggested scope and…

  9. Roadway Safety Guide

    DOT National Transportation Integrated Search

    2001-01-01

    Roadway safety refers to that portion of overall highway safety that is determined by the roadway's physical features such as road design, roadway signs, pavement markings, operating conditions, roadside objects (such as utility poles, signs, trees, ...

  10. A Process-Centered Tool for Evaluating Patient Safety Performance and Guiding Strategic Improvement

    DTIC Science & Technology

    2005-01-01

    next patient safety steps in individual health care organizations. The low priority given to Category 3 (Focus on patients , other customers , and...presents a patient safety applicator tool for implementing and assessing patient safety systems in health care institutions. The applicator tool consists...the survey rounds. The study addressed three research questions: 1. What critical processes should be included in health care patient safety systems

  11. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  12. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  13. Alcohol and Alcohol Safety: A Curriculum Manual for Senior High Level. Volume II, A Teacher's Activities Guide.

    ERIC Educational Resources Information Center

    Finn, Peter; Platt, Judith

    This curriculum manual on Alcohol and Alcohol Safety is designed as a teacher's guide for senior high level students. The topics it covers are: (1) safety; (2) attitudes toward alcohol and reasons people drink; (3) physical and behavioral effects; (4) alcohol industry; (5) interpersonal situations; (6) laws and customs; and (7) problem drinking…

  14. Alcohol and Alcohol Safety: A Curriculum Manual for Junior High Level. Volume II, A Teacher's Activities Guide.

    ERIC Educational Resources Information Center

    Finn, Peter; Platt, Judith

    This curriculum manual on Alcohol and Alcohol Safety is designed as a teacher's guide for junior high level students. The topics it covers are: (1) safety; (2) attitudes toward alcohol and reasons people drink; (3) physical and behavioral effects; (4) interpersonal situations; (5) laws and customs; and (6) problem drinking and alcoholism. Each…

  15. Vocational Safety Guide to Generalized Safety Provisions as They Apply to: Agricultural Education, Business and Office Education, Health Occupations Education, Home Economics Education, Industrial Arts Education, Marketing and Distributive Education, Trade and Technical Education.

    ERIC Educational Resources Information Center

    Dyrenfurth, Michael J.; Linhardt, Richard E.

    This vocational safety guide is designed to help Missouri school practitioners at all levels in providing for the safe instruction and work associated with practical arts and vocational and technical subjects. Covered in the individual sections of the guide are the following topics: Missouri legislation and regulations pertaining to school safety;…

  16. Update on Clinical MR-guided Focused Ultrasound Applications

    PubMed Central

    McDannold, Nathan

    2015-01-01

    SYNOPSIS Focused ultrasound (FUS) can be used to thermally ablate tissue. The performance of FUS under magnetic resonance (MR) guidance enables aiming the focus at the target, accurate treatment planning, real-time temperature mapping, and evaluation of the treatment. This review updates several clinical applications of MR-guided FUS. MR-guided FUS has a CE mark and FDA approval for thermal ablation for uterine fibroids and bone metastases related pain management. Thousands of uterine fibroid patients have successfully been treated with minor side effects. Technical improvements, increased experience, and the use of a screening MRI examination should further improve treatment outcome. When used for bone metastases and other bone diseases, thermal ablation leads to pain relief due to denervation, and debulking of the tumor. The use of a hemi-spherical multi-element transducer and phase corrections have enabled application of FUS through the skull. Transcranial MR-guided FUS has received CE certification for ablation of deep, central locations in the brain such as the thalamus. Thermal ablation of specific parts of the thalamus can result in relief of the symptoms in neurological disorders such as essential tremor, Parkinson’s, and neuropathic pain. No CE mark or FDA approval has been obtained as yet for treatment of prostate cancer or breast cancer, but several approaches have been proposed and clinical trials should show the potential of MR-guided FUS for these and other applications. PMID:26499282

  17. Biotechnology: Applications in Agriculture. Instructor Guide [and] Student Reference.

    ERIC Educational Resources Information Center

    Nevils, Aaron

    This curriculum guide incorporates the needed components to aid agriculture teachers in the implementation of the Vocational Instructional Management System in biotechnology: applications in agriculture. The guide begins with a list of the competencies/objectives found in the six units; list of references and materials; list of materials and…

  18. Connected commercial vehicles — retrofit safety device kit project : safety applications and development plan.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  19. Designing Tracking Software for Image-Guided Surgery Applications: IGSTK Experience

    PubMed Central

    Enquobahrie, Andinet; Gobbi, David; Turek, Matt; Cheng, Patrick; Yaniv, Ziv; Lindseth, Frank; Cleary, Kevin

    2009-01-01

    Objective Many image-guided surgery applications require tracking devices as part of their core functionality. The Image-Guided Surgery Toolkit (IGSTK) was designed and developed to interface tracking devices with software applications incorporating medical images. Methods IGSTK was designed as an open source C++ library that provides the basic components needed for fast prototyping and development of image-guided surgery applications. This library follows a component-based architecture with several components designed for specific sets of image-guided surgery functions. At the core of the toolkit is the tracker component that handles communication between a control computer and navigation device to gather pose measurements of surgical instruments present in the surgical scene. The representations of the tracked instruments are superimposed on anatomical images to provide visual feedback to the clinician during surgical procedures. Results The initial version of the IGSTK toolkit has been released in the public domain and several trackers are supported. The toolkit and related information are available at www.igstk.org. Conclusion With the increased popularity of minimally invasive procedures in health care, several tracking devices have been developed for medical applications. Designing and implementing high-quality and safe software to handle these different types of trackers in a common framework is a challenging task. It requires establishing key software design principles that emphasize abstraction, extensibility, reusability, fault-tolerance, and portability. IGSTK is an open source library that satisfies these needs for the image-guided surgery community. PMID:20037671

  20. Occupational Safety and Health in Vocational Education: A Guide for Administrators, Faculty, and Staff.

    ERIC Educational Resources Information Center

    Godbey, Frank W.

    This guide is intended to help administrators at schools having vocational education programs assess their occupational safety and health needs and establish a program to ensure a safer and more healthful work environment. It consists of three sections: (1) administrative guidelines, (2) technical-regulatory guidelines, and (3) a self-evaluation…

  1. Safety of High Speed and Guided Ground Transportation Systems: Collision Avoidance and Accident Survivability: Volume 3

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the third of four volumes concerned with developing safety guidelines and specifications for high-speed : guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in : this study i...

  2. 75 FR 45172 - Withdrawal of Regulatory Guides 3.44 and 3.49

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-02

    ... Format and Content for the Safety Analysis Report for an Independent Spent Fuel Storage Installation... on the format and content of the safety analysis report that is required as part of an application to...: Nuclear Regulatory Commission. ACTION: Withdrawal of Regulatory Guide 3.44, ``Standard Format and Content...

  3. Safety of high-speed guided ground transportation : collision avoidance and accident survivability : volume 1 : collision threat

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the first of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is to...

  4. Safety measurement and monitoring in healthcare: a framework to guide clinical teams and healthcare organisations in maintaining safety

    PubMed Central

    Vincent, Charles; Burnett, Susan; Carthey, Jane

    2014-01-01

    Patients, clinicians and managers all want to be reassured that their healthcare organisation is safe. But there is no consensus about what we mean when we ask whether a healthcare organisation is safe or how this is achieved. In the UK, the measurement of harm, so important in the evolution of patient safety, has been neglected in favour of incident reporting. The use of softer intelligence for monitoring and anticipation of problems receives little mention in official policy. The Francis Inquiry report into patient treatment at the Mid Staffordshire NHS Foundation Trust set out 29 recommendations on measurement, more than on any other topic, and set the measurement of safety an absolute priority for healthcare organisations. The Berwick review found that most healthcare organisations at present have very little capacity to analyse, monitor or learn from safety and quality information. This paper summarises the findings of a more extensive report and proposes a framework which can guide clinical teams and healthcare organisations in the measurement and monitoring of safety and in reviewing progress against safety objectives. The framework has been used so far to promote self-reflection at both board and clinical team level, to stimulate an organisational check or analysis in the gaps of information and to promote discussion of ‘what could we do differently’. PMID:24764136

  5. General Construction Trades. Volume 1. Teacher's Guide.

    ERIC Educational Resources Information Center

    East Texas State Univ., Commerce. Occupational Curriculum Lab.

    Ten units on the world of construction and twelve units on carpentry are presented in this teacher's guide. The construction units include the following: safety; human relations in the shop; grooming and hygiene; hand tools; measurement; portable power tools, stationary power tools; fastening devices; and job application and interview. The…

  6. Safety of High Speed Guided Ground Transportation Systems: Collision Avoidance and Accident Survivability Volume 4: Proposed Specifications

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the fourth of four volumes concerned with developing safety guidelines and specifications for high-speed : guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this : study ...

  7. Predictive Microbiology and Food Safety Applications

    USDA-ARS?s Scientific Manuscript database

    Mathematical modeling is the science of systematic study of recurrent events or phenomena. When models are properly developed, their applications may save costs and time. For microbial food safety research and applications, predictive microbiology models may be developed based on the fact that most ...

  8. Vision-guided micromanipulation system for biomedical application

    NASA Astrophysics Data System (ADS)

    Shim, Jae-Hong; Cho, Sung-Yong; Cha, Dong-Hyuk

    2004-10-01

    In these days, various researches for biomedical application of robots have been carried out. Particularly, robotic manipulation of the biological cells has been studied by many researchers. Usually, most of the biological cell's shape is sphere. Commercial biological manipulation systems have been utilized the 2-Dimensional images through the optical microscopes only. Moreover, manipulation of the biological cells mainly depends on the subjective viewpoint of an operator. Due to these reasons, there exist lots of problems such as slippery and destruction of the cell membrane and damage of the pipette tip etc. In order to overcome the problems, we have proposed a vision-guided biological cell manipulation system. The newly proposed manipulation system makes use of vision and graphic techniques. Through the proposed procedures, an operator can inject the biological cell scientifically and objectively. Also, the proposed manipulation system can measure the contact force occurred at injection of a biological cell. It can be transmitted a measured force to the operator by the proposed haptic device. Consequently, the proposed manipulation system could safely handle the biological cells without any damage. This paper presents the introduction of our vision-guided manipulation techniques and the concept of the contact force sensing. Through a series of experiments the proposed vision-guided manipulation system shows the possibility of application for precision manipulation of the biological cell such as DNA.

  9. Safety Guided Design Based on Stamp/STPA for Manned Vehicle in Concept Design Phase

    NASA Astrophysics Data System (ADS)

    Ujiie, Ryo; Katahira, Masafumi; Miyamoto, Yuko; Umeda, Hiroki; Leveson, Nancy; Hoshino, Nobuyuki

    2013-09-01

    In manned vehicles, such as the Soyuz and the Space Shuttle, the crew and computer system cooperate to succeed in returning to the earth. While computers increase the functionality of system, they also increase the complexity of the interaction between the controllers (human and computer) and the target dynamics. In some cases, the complexity can produce a serious accident. To prevent such losses, traditional hazard analysis such as FTA has been applied to system development, however it can be used after creating a detailed system because it focuses on detailed component failures. As a result, it's more difficult to eliminate hazard cause early in the process when it is most feasible.STAMP/STPA is a new hazard analysis that can be applied from the early development phase, with the analysis being refined as more detailed decisions are made. In essence, the analysis and design decisions are intertwined and go hand-in-hand. We have applied STAMP/STPA to a concept design of a new JAXA manned vehicle and tried safety guided design of the vehicle. As a result of this trial, it has been shown that STAMP/STPA can be accepted easily by system engineers and the design has been made more sophisticated from a safety viewpoint. The result also shows that the consequences of human errors on system safety can be analysed in the early development phase and the system designed to prevent them. Finally, the paper will discuss an effective way to harmonize this safety guided design approach with system engineering process based on the result of this experience in this project.

  10. Safety of high-speed guided ground transportation systems : collision avoidance and accident survivability : volume 4 : proposed specifications

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the fourth of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is t...

  11. Safety of high-speed guided ground transportation systems : collision avoidance and accident survivability : volume 3 : accident survivability

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the third of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is to...

  12. Safety of high-speed guided ground transportation systems : collision avoidance and accident survivability : volume 2 : collision avoidance

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the second of four volumes concerned with developing safety guidelines and specifications for high-speed guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this study is t...

  13. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  14. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  15. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  16. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  17. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  18. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  19. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  20. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  1. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  2. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  3. Health information technology and hospital patient safety: a conceptual model to guide research.

    PubMed

    Paez, Kathryn; Roper, Rebecca A; Andrews, Roxanne M

    2013-09-01

    The literature indicates that health information technology (IT) use may lead to some gains in the quality and safety of care in some situations but provides little insight into this variability in the results that has been found. The inconsistent findings point to the need for a conceptual model that will guide research in sorting out the complex relationships between health IT and the quality and safety of care. A conceptual model was developed that describes how specific health IT functions could affect different types of inpatient safety errors and that include contextual factors that influence successful health IT implementation. The model was applied to a readily available patient safety measure and nationwide data (2009 AHA Annual Survey Information Technology Supplement and 2009 Healthcare Cost and Utilization Project State Inpatient Databases). The model was difficult to operationalize because (1) available health IT adoption data did not characterize health IT features and extent of usage, and (2) patient safety measures did not elucidate the process failures leading to safety-related outcomes. The sample patient safety measure--Postoperative Physiologic and Metabolic Derangement Rate--was not significantly related to self-reported health IT capabilities when adjusted for hospital structural characteristics. These findings illustrate the critical need for collecting data that are germane to health IT and the possible mechanisms by which health IT may affect inpatient safety. Well-defined and sufficiently granular measures of provider's correct use of health IT functions, the contextual factors surrounding health IT use, and patient safety errors leading to health care-associated conditions are needed to illuminate the impact of health IT on patient safety.

  4. T & I--Building Construction, Safety. Kit No. 1. Instructor's Manual [and] Student Learning Activity Guide.

    ERIC Educational Resources Information Center

    Howard, John

    An instructor's manual and student activity guide on building construction safety are provided in this set of prevocational education materials which focuses on the vocational area of trade and industry. (This set of materials is one of ninety-two prevocational education sets arranged around a cluster of seven vocational offerings: agriculture,…

  5. Guide for the preparation of applications for Nuclear Pharmacy Licenses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-08-01

    The purpose of this regulatory guide is to provide assistance to applicants and licensees in preparing applications for new licenses, license amendments, and license renewals for the possession, use, and distribution of by-product material in nuclear pharmacy operations.

  6. Safety assessment guidance in the International Atomic Energy Agency RADWASS Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vovk, I.F.; Seitz, R.R.

    1995-12-31

    The IAEA RADWASS programme is aimed at establishing a coherent and comprehensive set of principles and standards for the safe management of waste and formulating the guidelines necessary for their application. A large portion of this programme has been devoted to safety assessments for various waste management activities. Five Safety Guides are planned to be developed to provide general guidance to enable operators and regulators to develop necessary framework for safety assessment process in accordance with international recommendations. They cover predisposal, near surface disposal, geological disposal, uranium/thorium mining and milling waste, and decommissioning and environmental restoration. The Guide on safetymore » assessment for near surface disposal is at the most advanced stage of preparation. This draft Safety Guide contains guidance on description of the disposal system, development of a conceptual model, identification and description of relevant scenarios and pathways, consequence analysis, presentation of results and confidence building. The set of RADWASS publications is currently undergoing in-depth review to ensure a harmonized approach throughout the Safety Series.« less

  7. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    PubMed

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  8. Ultrasound-Guided Regional Anesthesia and Patient Safety: Update of an Evidence-Based Analysis.

    PubMed

    Neal, Joseph M

    2016-01-01

    In 2010, the American Society of Regional Anesthesia and Pain Medicine's evidence-based medicine assessment of ultrasound (US)-guided regional anesthesia (UGRA) analyzed the effect of this nerve localization technology on patient safety. That analysis focused on 4 important regional anesthesia complications: peripheral nerve injury, local anesthetic systemic toxicity (LAST), hemidiaphragmatic paresis (HDP), and pneumothorax. In the intervening 5 years, further research has allowed us to refine our original conclusions. This update reviews previous findings and critically evaluates new literature published since late 2009 that compares the patient safety attributes of UGRA with those of traditional nerve localization methods. As with the previous version of this exercise, analysis focused on randomized controlled trials that compared UGRA with an alternative neural localization method and case series of more than 500 patients. The Jadad score was used to grade individual study quality, and conclusions were graded as to strength of evidence. Of those randomized controlled trials identified by our search techniques, 28 compared the incidence of postoperative nerve symptoms, 27 assessed LAST parameters, 7 studied HDP, and 9 reported the incidence of pneumothorax. The current analysis strengthens our original conclusions that US guidance has no significant effect on the incidence of postoperative neurologic symptoms and that UGRA reduces the incidence and intensity of HDP but does so in an unpredictable manner. Conversely, emerging evidence supports the effectiveness of US guidance for reducing LAST across its clinical presentation continuum. The predicted frequency of pneumothorax has grown smaller in tandem with increased experience with US-guided supraclavicular block. This evidence-based review summarizes both the power and the limitations of UGRA as a tool for improving patient safety. Since the original 2010 publication of this analysis, evidence has continued to

  9. Safety of High Speed and Ground Guided Transportation Systems: Collision Avoidance and Accident Survivability: Volume 1: Collision Threat

    DOT National Transportation Integrated Search

    1993-03-01

    This report is the first of four volunes concerned with developing safety guidelines and specifications for high-speed : guided ground transportation (HSGGT) collision avoidance and accident survivability. The overall approach taken in this : study i...

  10. Taking Student Expectations Seriously: A Guide for Campus Applications. NASPA-050

    ERIC Educational Resources Information Center

    Miller, Thomas; Kuh, George D.; Paine, Dorie

    2006-01-01

    Students' expectations for college form the foundation for the nature of the relationship they have with their college or university. "Taking Expectations Seriously: A Guide for Campus Applications" is the companion guide to "Promoting Reasonable Expectations: Aligning Student and Institutional Views of the College Experience" (Jossey-Bass, 2005).…

  11. Nursing Student Experiences Regarding Safe Use of Electronic Health Records: A Pilot Study of the Safety and Assurance Factors for EHR Resilience Guides.

    PubMed

    Whitt, Karen J; Eden, Lacey; Merrill, Katreena Collette; Hughes, Mckenna

    2017-01-01

    Previous research has linked improper electronic health record configuration and use with adverse patient events. In response to this problem, the US Office of the National Coordinator for Health Information Technology developed the Safety and Assurance Factors for EHR Resilience guides to evaluate electronic health records for optimal use and safety features. During the course of their education, nursing students are exposed to a variety of clinical practice settings and electronic health records. This descriptive study evaluated 108 undergraduate and 51 graduate nursing students' ratings of electronic health record features and safe practices, as well as what they learned from utilizing the computerized provider order entry and clinician communication Safety and Assurance Factors for EHR Resilience guide checklists. More than 80% of the undergraduate and 70% of the graduate students reported that they experienced user problems with electronic health records in the past. More than 50% of the students felt that electronic health records contribute to adverse patient outcomes. Students reported that many of the features assessed were not fully implemented in their electronic health record. These findings highlight areas where electronic health records can be improved to optimize patient safety. The majority of students reported that utilizing the Safety and Assurance Factors for EHR Resilience guides increased their understanding of electronic health record features.

  12. Adhesives: Test Method, Group Assignment, and Categorization Guide for High-Loading Rate Applications - History and Rationale

    DTIC Science & Technology

    2017-04-20

    Categorization Guide for High -Loading- Rate Applications – History and Rationale by Robert Jensen, David Flanagan, Daniel DeSchepper, and Charles...Adhesives: Test Method, Group Assignment, and Categorization Guide for High -Loading- Rate Applications – History and Rationale by Robert Jensen...Categorization Guide for High - Loading-Rate Applications – History and Rationale 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  13. Modeling and applications in microbial food safety

    USDA-ARS?s Scientific Manuscript database

    Mathematical modeling is a scientific and systematic approach to study and describe the recurrent events or phenomena with successful application track for decades. When models are properly developed and validated, their applications may save costs and time. For the microbial food safety concerns, ...

  14. Electronics. Module 3: Digital Logic Application. Instructor's Guide.

    ERIC Educational Resources Information Center

    Carter, Ed; Murphy, Mark

    This guide contains instructor's materials for a 10-unit secondary school course on digital logic application. The units are introduction to digital, logic gates, digital integrated circuits, combination logic, flip-flops, counters and shift registers, encoders and decoders, arithmetic circuits, memory, and analog/digital and digital/analog…

  15. Wire-guided sphincterotomy.

    PubMed

    Sherman, S; Uzer, M F; Lehman, G A

    1994-12-01

    Guidewire-assisted techniques have acquired an important role in endoscopic interventions in the pancreaticobiliary tree. The wire-guided sphincterotome allows the endoscopist to maintain direct access to the biliary tree before or after the sphincterotomy. It has the additional advantages of allowing for more expeditious placement of accessories and being useful in combined percutaneous-endoscopic procedures. There are two basic designs of wire-guided sphincterotomes. The single-channel model has a single lumen for both the cutting wire and guidewire and requires guidewire removal before the application of power. The double-channel model has two separate lumens for the guidewire and stainless steel cutting wire. In vitro data suggest that significant capacitive coupling currents (or short circuits) may occur on the standard Teflon-coated guidewire when used with a double lumen sphincterotome, resulting in electrosurgical burns. Thus, the manufacturers of the double-lumen models recommend removing the Teflon-coated wire before performing sphincterotomy. Although limited data in humans have been published, it appears that wire-guided sphincterotomy and standard sphincterotomy have similar complication rates. More safety information in humans is awaited.

  16. Software development for safety-critical medical applications

    NASA Technical Reports Server (NTRS)

    Knight, John C.

    1992-01-01

    There are many computer-based medical applications in which safety and not reliability is the overriding concern. Reduced, altered, or no functionality of such systems is acceptable as long as no harm is done. A precise, formal definition of what software safety means is essential, however, before any attempt can be made to achieve it. Without this definition, it is not possible to determine whether a specific software entity is safe. A set of definitions pertaining to software safety will be presented and a case study involving an experimental medical device will be described. Some new techniques aimed at improving software safety will also be discussed.

  17. Safety, Health, and Fire Prevention Guide for Hospital Safety Managers

    DTIC Science & Technology

    1993-03-01

    Safety committee S 2-5 Oxygen quality assurance program 0 2-6 Safety and fire prevention library 0 2-7 Safety services to Dental Activities • 2-8...Chapter 2 Safety Management 2-1. Safety policy statement Health Services Command (HSC) Supplement (Suppl) 1 to Army Regulation (AR) 385-10 and the...Management. (b) The medical staff. (c) The nursing service . (d) Logistics. (e) Nutritional care. (f) Preventive medicine. * 2-3 USAEHA TG No. 152 March 1993 (g

  18. Safety assessment in plant layout design using indexing approach: implementing inherent safety perspective. Part 1 - guideword applicability and method description.

    PubMed

    Tugnoli, Alessandro; Khan, Faisal; Amyotte, Paul; Cozzani, Valerio

    2008-12-15

    Layout planning plays a key role in the inherent safety performance of process plants since this design feature controls the possibility of accidental chain-events and the magnitude of possible consequences. A lack of suitable methods to promote the effective implementation of inherent safety in layout design calls for the development of new techniques and methods. In the present paper, a safety assessment approach suitable for layout design in the critical early phase is proposed. The concept of inherent safety is implemented within this safety assessment; the approach is based on an integrated assessment of inherent safety guideword applicability within the constraints typically present in layout design. Application of these guidewords is evaluated along with unit hazards and control devices to quantitatively map the safety performance of different layout options. Moreover, the economic aspects related to safety and inherent safety are evaluated by the method. Specific sub-indices are developed within the integrated safety assessment system to analyze and quantify the hazard related to domino effects. The proposed approach is quick in application, auditable and shares a common framework applicable in other phases of the design lifecycle (e.g. process design). The present work is divided in two parts: Part 1 (current paper) presents the application of inherent safety guidelines in layout design and the index method for safety assessment; Part 2 (accompanying paper) describes the domino hazard sub-index and demonstrates the proposed approach with a case study, thus evidencing the introduction of inherent safety features in layout design.

  19. Solar Energy Applications for Agriculture. A Curriculum Guide.

    ERIC Educational Resources Information Center

    Nebraska Univ., Lincoln. Dept. of Agricultural Education.

    This curriculum guide contains five units for a course in solar energy applications for vocational agriculture. Each unit is organized in a format containing some or all of the following materials: unit objective, specific objectives, suggested instructor and student activities, list of instructional materials, assignment sheets, answers to…

  20. Efficacy and safety of Duplex-guided polidocanol foam sclerotherapy for venous malformations.

    PubMed

    Ali, Haitham; Saleh, Mahmoud; Mohammed, Walid

    2017-06-01

    The aim of our study was to report our experience regarding the safety, efficacy of duplex-guided polidocanol (POL) foam sclerotherapy on the overall status of signs and symptoms in patients with venous malformations (VMs). Thirty seven patients with symptomatic extratruncular VMs were treated with duplex-guided POL foam sclerotherapy using Tessari's method. Twenty five patients had limited VMs, while twelve had infiltrating VMs. Postsclerotherapy surveillance was done 6 months after the last sclerotherapy session and comprised both clinical and duplex evaluation. Clinical evaluation entailed a patient self-assessment questionnaire using a four-point scale to rate the degree of symptoms improvement as follows: disappeared, decreased, worsened, or recurred. Findings obtained by duplex scanning were divided into four groups: 1) disappeared group; 2) partially recanalized group; 3) totally recanalized group; and 4) worsened group. There were 20 males and 17 females with mean age of 22.8±5.5 years. There was a significant reduction in the total amount of POL (P=0.0037), the number of sclerotherapy sessions was significantly lesser (P=0.0019), and treatment success was significantly higher (P=0.0495) in patients with limited VMs in comparison to those with infiltrating VMs. No major complications related to sclerotherapy were encountered in both groups. Polidocanol foam sclerotherapy is effective, and safe for treatment of VMs, with high success rate and low risk of major complications. Although associated with relatively high recurrence rate compared with ethanol sclerotherapy, this can be overcome by additional treatment sessions, given the relative simplicity, speed, and safety.

  1. A sensor monitoring system for telemedicine, safety and security applications

    NASA Astrophysics Data System (ADS)

    Vlissidis, Nikolaos; Leonidas, Filippos; Giovanis, Christos; Marinos, Dimitrios; Aidinis, Konstantinos; Vassilopoulos, Christos; Pagiatakis, Gerasimos; Schmitt, Nikolaus; Pistner, Thomas; Klaue, Jirka

    2017-02-01

    A sensor system capable of medical, safety and security monitoring in avionic and other environments (e.g. homes) is examined. For application inside an aircraft cabin, the system relies on an optical cellular network that connects each seat to a server and uses a set of database applications to process data related to passengers' health, safety and security status. Health monitoring typically encompasses electrocardiogram, pulse oximetry and blood pressure, body temperature and respiration rate while safety and security monitoring is related to the standard flight attendance duties, such as cabin preparation for take-off, landing, flight in regions of turbulence, etc. In contrast to previous related works, this article focuses on the system's modules (medical and safety sensors and associated hardware), the database applications used for the overall control of the monitoring function and the potential use of the system for security applications. Further tests involving medical, safety and security sensing performed in an real A340 mock-up set-up are also described and reference is made to the possible use of the sensing system in alternative environments and applications, such as health monitoring within other means of transport (e.g. trains or small passenger sea vessels) as well as for remotely located home users, over a wired Ethernet network or the Internet.

  2. DOE interpretations Guide to OSH standards. Update to the Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued its support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal interpretation letters written OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed by DOE.more » This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.« less

  3. DOE interpretations Guide to OSH standards. Update to the Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-03-31

    Reflecting Secretary O`Leary`s focus on occupational safety and health, the Office of Occupational Safety is pleased to provide you with the latest update to the DOE Interpretations Guide to OSH Standards. This Guide was developed in cooperation with the Occupational Safety and Health Administration, which continued it`s support during this last revision by facilitating access to the interpretations found on the OSHA Computerized Information System (OCIS). This March 31, 1994 update contains 123 formal in letter written by OSHA. As a result of the unique requests received by the 1-800 Response Line, this update also contains 38 interpretations developed bymore » DOE. This new occupational safety and health information adds still more important guidance to the four volume reference set that you presently have in your possession.« less

  4. Connected commercial vehicles — retrofit safety device kit project : safety applications performance and functional test plan and procedure.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  5. 78 FR 18419 - Office of Hazardous Materials Safety; Delayed Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Delayed Applications AGENCY: Pipeline and Hazardous Materials Safety.... FOR FURTHER INFORMATION CONTACT: Ryan Paquet, Director, Office of Hazardous Materials Special Permits...

  6. Protective Action Guides (PAGs)

    EPA Pesticide Factsheets

    The Protective Action Guide (PAG) manual contains radiation dose guidelines that would trigger public safety measures. EPA developed Protective Action Guides to help responders plan for radiation emergencies.

  7. Protecting Your Newborn. Instructor's Guide.

    ERIC Educational Resources Information Center

    Bhatia, Esha

    This guide is intended to help instructors educate new and expectant parents about safely transporting their newborn babies. The guide accompanies a 27-minute video, developed by the National Traffic Safety Administration, which introduces some of the key safety issues that new parents should consider during their baby's first 6 months of life.…

  8. Safety Psychology Applicating on Coal Mine Safety Management Based on Information System

    NASA Astrophysics Data System (ADS)

    Hou, Baoyue; Chen, Fei

    In recent years, with the increase of intensity of coal mining, a great number of major accidents happen frequently, the reason mostly due to human factors, but human's unsafely behavior are affected by insecurity mental control. In order to reduce accidents, and to improve safety management, with the help of application security psychology, we analyse the cause of insecurity psychological factors from human perception, from personality development, from motivation incentive, from reward and punishment mechanism, and from security aspects of mental training , and put forward countermeasures to promote coal mine safety production,and to provide information for coal mining to improve the level of safety management.

  9. Infant-Guided, Co-Regulated Feeding in the Neonatal Intensive Care Unit. Part II: Interventions to Promote Neuroprotection and Safety.

    PubMed

    Shaker, Catherine S

    2017-04-01

    Feeding skills of preterm neonates in a neonatal intensive care unit are in an emergent phase of development and require careful support to minimize stress. The underpinnings that influence and enhance both neuroprotection and safety were discussed in Part I. An infant-guided, co-regulated approach to feeding can protect the vulnerable neonate's neurologic development, support the parent-infant relationship, and prevent feeding problems that may endure. Contingent interventions are used to maintain subsystem stability and enhance self-regulation, development, and coping skills. This co-regulation between caregiver and neonate forms the foundation for a positive infant-guided feeding experience. Caregivers select evidence-based interventions contingent to the newborn's communication. When these interventions are then titrated from moment to moment, neuroprotection and safety are fostered. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Safety Guided Design of Crew Return Vehicle in Concept Design Phase Using STAMP/STPA

    NASA Astrophysics Data System (ADS)

    Nakao, H.; Katahira, M.; Miyamoto, Y.; Leveson, N.

    2012-01-01

    In the concept development and design phase of a new space system, such as a Crew Vehicle, designers tend to focus on how to implement new technology. Designers also consider the difficulty of using the new technology and trade off several system design candidates. Then they choose an optimal design from the candidates. Safety should be a key aspect driving optimal concept design. However, in past concept design activities, safety analysis such as FTA has not used to drive the design because such analysis techniques focus on component failure and component failure cannot be considered in the concept design phase. The solution to these problems is to apply a new hazard analysis technique, called STAMP/STPA. STAMP/STPA defines safety as a control problem rather than a failure problem and identifies hazardous scenarios and their causes. Defining control flow is the essential in concept design phase. Therefore STAMP/STPA could be a useful tool to assess the safety of system candidates and to be part of the rationale for choosing a design as the baseline of the system. In this paper, we explain our case study of safety guided concept design using STPA, the new hazard analysis technique, and model-based specification technique on Crew Return Vehicle design and evaluate benefits of using STAMP/STPA in concept development phase.

  11. Safety design considerations for lithium batteries in CF applications

    NASA Astrophysics Data System (ADS)

    Moroz, W. J.

    1981-02-01

    Lithium-sulphur dioxide (Li-SO2) primary cells are being introduced as power supplies into Canadian Forces applications where advantage can be taken of their high energy density characteristics and low temperature capabilities. For safety reasons the high energy capabilities of these cells must be protected against the possibility of accidental abuse. DREO has investigated and identified a number of operational problem areas associated with Li-SO2 systems. Safety design considerations are proposed for three CF applications; the PRC 515 Radio Set/Radar Transponder SST-181X applications and the AN/PRQ-501 Personal Locater Beacon.

  12. The Evaluation of the Safety Benefits of Combined Passive and On-Board Active Safety Applications

    PubMed Central

    Page, Yves; Cuny, Sophie; Zangmeister, Tobias; Kreiss, Jens-Peter; Hermitte, Thierry

    2009-01-01

    One of the objectives of the European TRACE project (TRaffic Accident Causation in Europe, 2006–2008) was to estimate the proportion of injury accidents that could be avoided and/or the proportion of injury accidents where the severity could be mitigated for on-the-market safety applications, if 100 % of the car fleet would be equipped with them. We have selected for evaluation the Electronic Stability Control (ESC) and the Emergency Brake Assist (EBA) applications. As for passive safety systems, recent cars are designed to offer overall safety protection. Car structure, load limiters, front airbags, side airbags, knee airbags, pretensioners, padding and non aggressive structures in the door panel, the dashboard, the windshield, the seats, and the head rest also contribute to applying more protection. The whole safety package is very difficult to evaluate separately, one element independently segmented from the others. We decided to consider evaluating the effectivenessof the whole passive safety package, This package,, for the sake of simplicity, was the number of stars awarded at the Euro NCAP testing. The challenges were to compare the effectiveness of some safety configuration SC I, with the effectiveness of a different safety configuration SC II. A safety configuration is understood as a package of safety functions. Ten comparisons have been carried out such as the evaluation of the safety benefit of a fifth star given that the car has four stars and an EBA. The main outcome of this analysis is that any addition of a passive or active safety function selected in this analysis is producing increased safety benefits. For example, if all cars were five stars fitted with EBA and ESC, instead of four stars without ESC and EBA, injury accidents would be reduced by 47.2% for severe injuries and 69.5% for fatal injuries. PMID:20184838

  13. Safety in Academic Chemistry Laboratories. Fourth Edition.

    ERIC Educational Resources Information Center

    American Chemical Society, Washington, DC.

    This booklet provides guidelines for safety in the chemical laboratory. Part I, "Guides for Instructors and Administrators," includes safety rules, safety practices and facilities, preparation for emergencies, safety committees, accident reporting, fire insurance, and listings of some hazardous chemicals. Part II, "Student Guide to…

  14. Emergency Medical Dispatch. National Standard Curriculum. Instructor Guide. Trainee Guide.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This guide contains all instructor materials and requirements for the National Highway Traffic Safety Administration (NHTSA), Emergency Medical Dispatch (EMD) National Standard Curriculum. It includes lesson plans, instructional aids, and tools and supporting information designed to elevate trained and experienced public safety telecommunicators…

  15. Applicability of the Common Safety Method for Risk Evaluation and Assessment (CSM-RA) to the Space Domain

    NASA Astrophysics Data System (ADS)

    Moreira, Francisco; Silva, Nuno

    2016-08-01

    Safety systems require accident avoidance. This is covered by application standards, processes, techniques and tools that support the identification, analysis, elimination or reduction to an acceptable level of system risks and hazards. Ideally, a safety system should be free of hazards. However, both industry and academia have been struggling to ensure appropriate risk and hazard analysis, especially in what concerns completeness of the hazards, formalization, and timely analysis in order to influence the specifications and the implementation. Such analysis is also important when considering a change to an existing system. The Common Safety Method for Risk Evaluation and Assessment (CSM- RA) is a mandatory procedure whenever any significant change is proposed to the railway system in a European Member State. This paper provides insights on the fundamentals of CSM-RA based and complemented with Hazard Analysis. When and how to apply them, and the relation and similarities of these processes with industry standards and the system life cycles is highlighted. Finally, the paper shows how CSM-RA can be the basis of a change management process, guiding the identification and management of the hazards helping ensuring the similar safety level as the initial system. This paper will show how the CSM-RA principles can be used in other domains particularly for space system evolution.

  16. Safety of ultrasound-guided high-intensity focused ultrasound ablation for diffuse adenomyosis: A retrospective cohort study.

    PubMed

    Feng, Yujie; Hu, Liang; Chen, Wenzhi; Zhang, Rong; Wang, Xi; Chen, Jinyun

    2017-05-01

    To evaluate the safety of ultrasound-guided high-intensity focused ultrasound (HIFU) ablation for patients with diffuse adenomyosis. This was a retrospective cohort study. The data was collected from 417 symptomatic adenomyosis patients who underwent ultrasound-guided HIFU between January 2012 and December 2015 at 1st Affiliated Hospital of Chongqing Medical University, Chongqing, China. Among them were 260 patients with diffuse adenomyosis (Group D) and 157 patients with focal adenomyosis (Group F). All patients underwent contrast-enhanced magnetic resonance imaging (MRI) one week before and the day after HIFU treatment. Successful treatment with HIFU was measured by the non-perfused volume ratio (NPVR). Intraprocedural and postprocedural adverse effects and complications were recorded to assess the safety of the procedure. Patients were followed-up for three months post-treatment. Complications were given a grade A through F according to the SIR Standards. All patients successfully completed the procedure, non-perfused regions appeared in 415 (99.5%) patients. The non-perfused volume ratio (NPVR) of Group D was significantly lower than that of Group F (P<0.05). During the procedure, the odds ratio of skin-burning pain was 1.7 (OR=1.617, 95% CI: 1.103-2.532), when comparing Group D with Group F, while the odds ratio of inguinal pain was equal to 2.0 (OR=2.038, 95% CI: 1.161-3.580), when Group F was compared to Group D. 97 patients (23.3%) received nominal therapy due to complications ([Society of interventional radiology, SIR]-B grade), among them, there were 62 cases (23.8%) in Group D and 35 cases (22.3%) in Group F. No significant difference was found between the two groups (P>0.05) and neither of the reported complications of SIR-C-SIR-F occurred within the two groups. Based on our results, ultrasound-guided HIFU is safe for the treatment of diffuse adenomyosis, and controlling the ablation zone is crucial to ensure patients' safety. Copyright © 2016 Elsevier

  17. Guide for preparing annual reports on radiation-safety testing of electronic products (general)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    For manufacturers of electronic products other than those for which a specific guide has been issued, the guide replaces the Guide for the Filing of Annual Reports (21 CFR Subchapter J, Section 1002.11), HHS Publication FDA 82-8127. The electronic product (general) annual reporting guide is applicable to the following products: products intended to produce x radiation (accelerators, analytical devices, therapy x-ray machines); microwave diathermy machines; cold-cathode discharge tubes; and vacuum switches and tubes operating at or above 15,000 volts. To carry out its responsibilities under Public Law 90-602, the Food and Drug Administration's Center for Devices and Radiological Health (CDRH)more » has issued a series of regulations contained in Title 21 of the Code of Federal Regulations (CFR). Part 1002 of 21 CFR deals with records and reports. Section 1002.61 categorizes electronic products into Groups A through C. Section 1002.30 requires manufacturers of products in Groups B and C to establish and maintain certain records, while Section 1002.11 requires such manufacturers to submit an Annual Report summarizing the contents of the required records. Section 1002.7 requires that reports conform to reporting guides issued by CDRH unless an acceptable justification for an alternate format is provided.« less

  18. A practical guide on DTA model applications for regional planning

    DOT National Transportation Integrated Search

    2016-06-07

    This document is intended as a guide for use by Metropolitan Planning Organizations (MPO) and other planning agencies that are interested in applying Dynamic Traffic Assignment (DTA) models for planning applications. The objective of this document is...

  19. A Safety and Health Guide for Vocational Educators. Incorporating Requirements of the Occupational Safety and Health Act of 1970, Relevant Pennsylvania Requirements with Particular Emphasis for Those Concerned with Cooperative Education and Work Study Programs. Volume 15. Number 1.

    ERIC Educational Resources Information Center

    Wahl, Ray

    Intended as a guide for vocational educators to incorporate the requirements of the Occupational Safety and Health Act (1970) and the requirements of various Pennsylvania safety and health regulations with their cooperative vocational programs, the first chapter of this document presents the legal implications of these safety and health…

  20. 7T: Physics, safety, and potential clinical applications.

    PubMed

    Kraff, Oliver; Quick, Harald H

    2017-12-01

    With more than 60 installed magnetic resonance imaging (MRI) systems worldwide operating at a magnetic field strength of 7T or higher, ultrahigh-field (UHF) MRI has been established as a platform for clinically oriented research in recent years. Profound technical and methodological developments have helped overcome the inherent physical challenges of UHF radiofrequency (RF) signal homogenization in the human body. The ongoing development of dedicated RF coil arrays was pivotal in realizing UHF body MRI, beyond mere brain imaging applications. Another precondition to clinical application of 7T MRI is the safety testing of implants and the establishment of safety concepts. Against this backdrop, 7T MRI and MR spectroscopy (MRS) recently have demonstrated capabilities and potentials for clinical diagnostics in a variety of studies. This article provides an overview of the immanent physical challenges of 7T UHF MRI and discusses recent technical solutions and safety concepts. Furthermore, recent clinically oriented studies are highlighted that span a broad application spectrum from 7T UHF brain to body MRI. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1573-1589. © 2017 International Society for Magnetic Resonance in Medicine.

  1. Medical and biohazardous waste generator`s guide: Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-09-01

    This Guide describes the procedures required to comply with all federal and state laws and regulations and Lawrence Berkeley Laboratory (LBL) policy applicable to medical and biohazardous waste. The members of the LBL Biological Safety Subcommittee participated in writing these policies and procedures. The procedures and policies in this Guide apply to LBL personnel who work with infectious agents or potentially infectious agents, publicly perceived infectious items or materials (e.g., medical gloves, culture dishes), and sharps (e.g., needles, syringes, razor blades). If medical or biohazardous waste is contaminated or mixed with a hazardous chemical or material, with a radioactive material,more » or with both, the waste will be handled in accordance with the applicable federal and State of California laws and regulations for hazardous, radioactive, or mixed waste.« less

  2. Canada's Intelligent Transportation Systems (ITS) : deployment and integration plan : applicant's guide

    DOT National Transportation Integrated Search

    2000-02-01

    This document is the applicant's guide for proposing intelligent transportation systems projects to Transport Canada and details such matters as eligibility, Transport Canada's program objectives and assessment of projects

  3. Pesticide Application and Safety Training. Sale Publication 4070.

    ERIC Educational Resources Information Center

    Stimmann, M. W.

    This guide is intended for use by those preparing to take the California certification examination for commercial pesticide applicators. The first chapter gives brief descriptions and illustrations of types of insect, vertebrate, plant, and microorganism pests. The other chapters cover pesticide classifications and formulations, labels and…

  4. Machine Shop. Module 1: Machine Shop Orientation and Math. Instructor's Guide.

    ERIC Educational Resources Information Center

    Curtis, Donna; Nobles, Jack

    This document consists of materials for a six-unit course on employment in the machine shop setting, safety, basic math skills, geometric figures and forms, math applications, and right triangles. The instructor's guide begins with a list of competencies covered in the module, descriptions of the materials included, an explanation of how to use…

  5. 29 CFR 500.102 - Applicability of vehicle safety standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 3 2011-07-01 2011-07-01 false Applicability of vehicle safety standards. 500.102 Section 500.102 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR REGULATIONS MIGRANT AND SEASONAL AGRICULTURAL WORKER PROTECTION Motor Vehicle Safety and Insurance for Transportation of Migrant and Seasonal...

  6. Simplifying applications software for vision guided robot implementation

    NASA Technical Reports Server (NTRS)

    Duncheon, Charlie

    1994-01-01

    A simple approach to robot applications software is described. The idea is to use commercially available software and hardware wherever possible to minimize system costs, schedules and risks. The U.S. has been slow in the adaptation of robots and flexible automation compared to the fluorishing growth of robot implementation in Japan. The U.S. can benefit from this approach because of a more flexible array of vision guided robot technologies.

  7. A Mouse Geneticist’s Practical Guide to CRISPR Applications

    PubMed Central

    Singh, Priti; Schimenti, John C.; Bolcun-Filas, Ewelina

    2015-01-01

    CRISPR/Cas9 system of RNA-guided genome editing is revolutionizing genetics research in a wide spectrum of organisms. Even for the laboratory mouse, a model that has thrived under the benefits of embryonic stem (ES) cell knockout capabilities for nearly three decades, CRISPR (Clustered Regularly Interspaced Short Palindromic Repeats)/Cas9 technology enables one to manipulate the genome with unprecedented simplicity and speed. It allows generation of null, conditional, precisely mutated, reporter, or tagged alleles in mice. Moreover, it holds promise for other applications beyond genome editing. The crux of this system is the efficient and targeted introduction of DNA breaks that are repaired by any of several pathways in a predictable but not entirely controllable manner. Thus, further optimizations and improvements are being developed. Here, we summarize current applications and provide a practical guide to use the CRISPR/Cas9 system for mouse mutagenesis, based on published reports and our own experiences. We discuss critical points and suggest technical improvements to increase efficiency of RNA-guided genome editing in mouse embryos and address practical problems such as mosaicism in founders, which complicates genotyping and phenotyping. We describe a next-generation sequencing strategy for simultaneous characterization of on- and off-target editing in mice derived from multiple CRISPR experiments. Additionally, we report evidence that elevated frequency of precise, homology-directed editing can be achieved by transient inhibition of the Ligase IV-dependent nonhomologous end-joining pathway in one-celled mouse embryos. PMID:25271304

  8. Apply Pesticides Correctly, A Guide for Commercial Applicators: Food Processing Pest Control.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide contains basic information to meet specific standards for pesticide applicators. Characteristics, life cycles and habits of pests such as roaches, beetles, flies, ants and rodents are discussed. Additionally, pest control measures, especially by application of aerosols, dusts, baits, fumigants or vapors, is presented. (CS)

  9. 76 FR 46330 - NUREG-1934, Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG); Second Draft...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2009-0568] NUREG-1934, Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG); Second Draft Report for Comment AGENCY: Nuclear Regulatory Commission... 1023259), ``Nuclear Power Plant Fire Modeling Application Guide (NPP FIRE MAG), Second Draft Report for...

  10. Overview of Therapeutic Ultrasound Applications and Safety Considerations

    PubMed Central

    Miller, Douglas; Smith, Nadine; Bailey, Michael; Czarnota, Gregory; Hynynen, Kullervo; Makin, Inder

    2013-01-01

    Summary Applications of ultrasound in medicine for therapeutic purposes have been an accepted and beneficial use of ultrasonic biological effects for many years. Low power ultrasound of about 1 MHz frequency has been widely applied since the 1950s for physical therapy in conditions such as tendinitis or bursitis. In the 1980s, high pressure-amplitude shockwaves came into use for mechanically resolving kidney stones, and “lithotripsy” rapidly replaced surgery as the most frequent treatment choice. The use of ultrasonic energy for therapy continues to expand, and approved applications now include uterine fibroid ablation, cataract removal (phacoemulsification), surgical tissue cutting and hemostasis, transdermal drug delivery, and bone fracture healing, among others. Undesirable bioeffects can occur including burns for thermal-based therapies and significant hemorrhage for mechanical-based therapies (e. g. lithotripsy). In all these therapeutic applications for bioeffects of ultrasound, standardization, ultrasound dosimetry, benefits assurance and side-effects risk minimization must be carefully considered in order to insure an optimal benefit to risk ratio for the patient. Therapeutic ultrasound typically has well-defined benefits and risks, and therefore presents a tractable safety problem to the clinician. However, safety information can be scattered, confusing or subject to commercial conflict of interest. Of paramount importance for managing this problem is the communication of practical safety information by authoritative groups, such as the AIUM, to the medical ultrasound community. In this overview, the Bioeffects Committee outlines the wide range of therapeutic ultrasound methods, which are in clinical use or under study, and provides general guidance for assuring therapeutic ultrasound safety. PMID:22441920

  11. 75 FR 52392 - Office Of Hazardous Materials Safety; Notice of Application for Special Permits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... DEPARTMENT OF TRANSPORTATION Pipeline And Hazardous Materials Safety Administration Office Of Hazardous Materials Safety; Notice of Application for Special Permits AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: List of applications for special permits. SUMMARY: In...

  12. CRISPR guide RNA design for research applications.

    PubMed

    Mohr, Stephanie E; Hu, Yanhui; Ewen-Campen, Benjamin; Housden, Benjamin E; Viswanatha, Raghuvir; Perrimon, Norbert

    2016-09-01

    The rapid rise of CRISPR as a technology for genome engineering and related research applications has created a need for algorithms and associated online tools that facilitate design of on-target and effective guide RNAs (gRNAs). Here, we review the state of the art in CRISPR gRNA design for research applications of the CRISPR-Cas9 system, including knockout, activation, and inhibition. Notably, achieving good gRNA design is not solely dependent on innovations in CRISPR technology. Good design and design tools also rely on availability of high-quality genome sequence and gene annotations, as well as on availability of accumulated data regarding off-targets and effectiveness metrics. © 2016 The Authors. The FEBS Journal published by John Wiley & Sons Ltd on behalf of Federation of European Biochemical Societies.

  13. Nanotechnology in food science: Functionality, applicability, and safety assessment.

    PubMed

    He, Xiaojia; Hwang, Huey-Min

    2016-10-01

    Rapid development of nanotechnology is expected to transform many areas of food science and food industry with increasing investment and market share. In this article, current applications of nanotechnology in food systems are briefly reviewed. Functionality and applicability of food-related nanotechnology are highlighted in order to provide a comprehensive view on the development and safety assessment of nanotechnology in the food industry. While food nanotechnology offers great potential benefits, there are emerging concerns arising from its novel physicochemical properties. Therefore, the safety concerns and regulatory policies on its manufacturing, processing, packaging, and consumption are briefly addressed. At the end of this article, the perspectives of nanotechnology in active and intelligent packaging applications are highlighted. Copyright © 2016. Published by Elsevier B.V.

  14. 78 FR 37653 - Notice of Fiscal Year (FY) 2014 Safety Grants and Solicitation for Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration Notice of Fiscal Year (FY) 2014 Safety Grants and Solicitation for Applications AGENCY: Federal Motor Carrier Safety.... SUMMARY: FMCSA announces the availability of FY 2014 safety grant opportunities and application due dates...

  15. CityGuideTour Toruń - tourist application using augmented reality

    NASA Astrophysics Data System (ADS)

    Węgrzyn, Magdalena; Mościcka, Albina

    2017-12-01

    The aim of the article is to show the possibilities of augmented reality in the fi eld of geodesy and cartography. It discusses the concept of augmented reality, its origins and development, as well as areas of the existing applications. The practical functioning of augmented reality in the area of geodesy and cartography is presented on the example of an application developed for the tourist city of Toruń, created with the use of CityGuideTour software. The principles of developing an application and the way it operates are also discussed. As a result, a fully operational bilingual application is available free of charge on the Web.

  16. Commercial grade item (CGI) dedication of generators for nuclear safety related applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, R.K.; Hajos, L.G.

    1993-03-01

    The number of nuclear safety related equipment suppliers and the availability of spare and replacement parts designed specifically for nuclear safety related application are shrinking rapidly. These have made it necessary for utilities to apply commercial grade spare and replacement parts in nuclear safety related applications after implementing proper acceptance and dedication process to verify that such items conform with the requirements of their use in nuclear safety related application. The general guidelines for the commercial grade item (CGI) acceptance and dedication are provided in US Nuclear Regulatory Commission (NRC) Generic Letters and Electric Power Research Institute (EPRI) Report NP-5652,more » Guideline for the Utilization of Commercial Grade Items in Nuclear Safety Related Applications. This paper presents an application of these generic guidelines for procurement, acceptance, and dedication of a commercial grade generator for use as a standby generator at Salem Generating Station Units 1 and 2. The paper identifies the critical characteristics of the generator which once verified, will provide reasonable assurance that the generator will perform its intended safety function. The paper also delineates the method of verification of the critical characteristics through tests and provide acceptance criteria for the test results. The methodology presented in this paper may be used as specific guidelines for reliable and cost effective procurement and dedication of commercial grade generators for use as standby generators at nuclear power plants.« less

  17. Application of guided acoustic waves to delamination detection

    NASA Technical Reports Server (NTRS)

    Sun, Keun J.

    1992-01-01

    Guided plate waves are able to interact with structural flaws such as delaminations and cracks due to their propagation properties highly sensitive to the thickness change in materials. A technique which employs an acoustic damper to probe the results of this interaction and then to locate flaws in a relatively short period of time is developed. With its technical advantages, this technique shows its potential application to large area structural integrity assessment.

  18. Arizona Traffic Safety Education, K-3. Pedestrian Safety, Grade 3.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains nine lessons on pedestrian safety for use in grade 3. Introductory information provided for the teacher includes basic highway safety concepts, stressing communication methods for…

  19. Arizona Traffic Safety Education, K-8. Pedestrian Safety, Grade 2.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains eight lessons on pedestrian safety for use in grade 2. Introductory information provided for the teacher includes basic highway safety concepts, stressing communication methods for…

  20. An organizational process for promoting home fire safety in two community settings.

    PubMed

    Lehna, Carlee; Twyman, Stephanie; Fahey, Erin; Coty, Mary-Beth; Williams, Joe; Scrivener, Drane; Wishnia, Gracie; Myers, John

    2017-02-01

    The purpose of this study was to describe the home fire safety quality improvement model designed to aid organizations in achieving institutional program goals. The home fire safety model was developed from community-based participatory research (CBPR) applying training-the-trainer methods and is illustrated by an institutional case study. The model is applicable to other types of organizations to improve home fire safety in vulnerable populations. Utilizing the education model leaves trained employees with guided experience to build upon, adapt, and modify the home fire safety intervention to more effectively serve their clientele, promote safety, and meet organizational objectives. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  1. Pocket guide to transportation, 2000

    DOT National Transportation Integrated Search

    1999-12-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into five sections: (1) transportation system extent, (2) transportation and safety, (3) mobility, (4) transportation and the economy,...

  2. Experiments applications guide: Advanced Communications Technology Satellite (ACTS)

    NASA Technical Reports Server (NTRS)

    1988-01-01

    This applications guide first surveys the capabilities of the Advanced Communication Technology Satellite (ACTS) system (both the flight and ground segments). This overview is followed by a description of the baseband processor (BBP) and microwave switch matrix (MSM) operating modes. Terminals operating with the baseband processor are referred to as low burst rate (LBR); and those operating with the microwave switch matrix, as high burst rate (HBR). Three very small-aperture terminals (VSATs), LBR-1, LBR-2, and HBR, are described for various ACTS operating modes. Also described is the NASA Lewis link evaluation terminal. A section on ACTS experiment opportunities introduces a wide spectrum of network control, telecommunications, system, and scientific experiments. The performance of the VSATs is discussed in detail. This guide is intended as a catalyst to encourage participation by the telecommunications, business, and science communities in a broad spectrum of experiments.

  3. MO-DE-202-03: Image-Guided Surgery and Interventions in the Advanced Multimodality Image-Guided Operating (AMIGO) Suite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kapur, T.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41

  4. Drafting Lab Management Guide.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Instructional Materials Lab.

    This manual was developed to guide drafting instructors and vocational supervisors in sequencing laboratory instruction and controlling the flow of work for a 2-year machine trades training program. The first part of the guide provides information on program management (program description, safety concerns, academic issues, implementation…

  5. Arizona Traffic Safety Education, K-8. Passenger Safety, Grade 3.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains four lessons and an appendix of school bus safety tips for use in grade 3. Introductory information provided for the teacher includes basic highway safety concepts, stressing…

  6. Transit safety retrofit package development : applications requirements document.

    DOT National Transportation Integrated Search

    2014-05-01

    This Application Requirements Document for the Transit Safety Retrofit Package (TRP) Development captures the system, hardware and software requirements towards fulfilling the technical objectives stated within the contract. To achieve the objective ...

  7. HSM implementation guide for managers.

    DOT National Transportation Integrated Search

    2011-09-01

    This guide is intended for managers of departments of transportation (DOT) charged with leading and managing agency programs impacting the project development process and safety programs. This guide is based on lessons learned from early adopters of ...

  8. Pocket guide to transportation, 2004

    DOT National Transportation Integrated Search

    2004-01-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) Transportation System Extent and Use, (2) Transportation Safety, (3) Transportation Security, (4...

  9. Pocket guide to transportation, 2005

    DOT National Transportation Integrated Search

    2005-01-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) Transportation System Extent and Use, (2) Transportation Safety, (3) Transportation Security, (4...

  10. Pocket guide to transportation, 2003

    DOT National Transportation Integrated Search

    2003-01-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) Transportation System Extent and Use, (2) Transportation Safety, (3) Transportation Security, (4...

  11. Pocket guide to transportation, 2001

    DOT National Transportation Integrated Search

    2000-12-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into five sections and a glossary: (1) Transportation System Extent and Use, (2) Transportation and Safety, (3) Mobility, (4) Transpor...

  12. Pocket guide to transportation, 2002

    DOT National Transportation Integrated Search

    2002-02-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into five sections and a glossary: (1) Transportation System Extent and Use, (2) Transportation and Safety, (3) Mobility, (4) Transpor...

  13. Federal Student Aid Handbook, 2006-2007. Application and Verification Guide

    ERIC Educational Resources Information Center

    US Department of Education, 2006

    2006-01-01

    This publication is intended for financial aid administrators and counselors who help students begin the student aid process--filing the Free Application for Federal Student Aid (FAFSA), verifying information, and making corrections and other changes to the information reported on the FAFSA. This guide contains the following chapters: (1) The…

  14. Water Worlds. 4-H Member's Guide M-5-18; 4-H Leaders Guide L-5-18.

    ERIC Educational Resources Information Center

    Hawkes, Janet E.; And Others

    This pocket folder of materials is designed to provide children aged 9 to 12 with an opportunity to explore and observe aquatic environments. The package includes a 4-H Leader's guide, member's guide, and supplementary materials. The leader's guide contains safety considerations, tips and techniques, and additional activities for getting started…

  15. Curriculum Guide Construction Cluster.

    ERIC Educational Resources Information Center

    Kline, Ken

    As part of a model construction cluster curriculum development project, this guide was developed and implemented in the Beaverton (Oregon) School District. The curriculum guide contains 16 units covering the following topics: introduction to construction jobs; safety and first aid; blueprint readings; basic mathematics; site work; framing; roofing…

  16. A guide to safe field operations

    USGS Publications Warehouse

    Yobbi, D.K.; Yorke, T.H.; Mycyk, R.T.

    1996-01-01

    Most functions of the U.S. Geological Survey (USGS), Water Resources Division (WRD) require employees to participate in numerous field activities ranging from routine meetings with cooperators, other federal and public officials, and private citizens to potentially hazardous assignments, such as making flood measurements and scuba diving to service underwater instruments. It is paramount that each employee be aware of safety procedures and operational policies of the WRD to ensure that (1) their activities avoid or minimize personal injury to the employee, coworkers, or anyone in the vicinity of the field activity, and (2) their conduct does not infringe on the personal or property rights of any individual or organization. The purpose of the guide is to familiarize employees with the operational and safety procedures expected to be followed by each employee as a representative of the WRD. It is also intended as a training tool for all new employees and a document to be reviewed by each employee before undertaking a field assignment. It includes general procedures that are standard and applicable to all field operations, such as communication, vehicle operation, and adequate preparation for anticipated weather conditions. It also includes a discussion of specific procedures and safety considerations for most of the routine field assignments undertaken by hydrologists and hydrologic technicians of the WRD. The guide is not intended to be a technical handbook outlining step-by-step procedures for performing specific tasks or a comprehensive discussion of every possible activity that may be undertaken by a USGS employee. Employees are referred to the Techniques for Water-Resources Investigations (TWRI) series for specific technical procedures and to the U.S. Geological Survey Safety and Environmental Health Handbook 445-1-H (USGS, August 1989), USGS Occupational Hazards and Safety Procedures Handbook 445-2-H (December 1993), the WRD notebook on Safety Policy and

  17. Wavefront-Guided versus Non-Wavefront-Guided Photorefractive Keratectomy for Myopia: Meta-Analysis of Randomized Controlled Trials

    PubMed Central

    Kobashi, Hidenaga; Kamiya, Kazutaka; Hoshi, Keika; Igarashi, Akihito; Shimizu, Kimiya

    2014-01-01

    Purpose To compare the efficacy, predictability, safety, and induced higher-order aberrations (HOAs) between wavefront-guided and non-wavefront-guided photorefractive keratectomy (PRK). Methods The Cochrane Central Register of Controlled Trials, PubMED, and EMBASE were searched for randomized controlled trials. Trials meeting the selection criteria were quality appraised, and data was extracted by 2 independent authors. Measures of association were pooled quantitatively using meta-analytical methods. Comparisons between wavefront-guided and non-wavefront-guided ablations were made as pooled odds ratios (ORs) or weighted mean differences. The pooled ORs and 95% confidence intervals (CIs) were computed for efficacy, safety, and predictability. The weighted mean differences and 95% CIs were used to compare induced HOAs. Results The study covered five trials involving 298 eyes. After wavefront-guided PRK, the pooled OR of achieving an uncorrected distance visual acuity of 20/20 (efficacy) was 1.18 (95% CI, 0.53–2.60; p = 0.69), the pooled OR of achieving a result within ±0.50 diopter of the intended target (predictability) was 0.86 (95% CI, 0.40–1.84; p = 0.70). No study reported a loss of 2 or more lines of Snellen acuity (safety) with either modality. In eyes with wavefront-guided PRK, the postoperative trefoil aberrations (mean difference −0.02; 95% CI, −0.03 to −0.00; p = 0.03) were significantly lower. There were no significant differences between the two groups in the postoperative total HOAs (mean difference −0.04; 95% CI, −0.23 to 0.14; p = 0.63), spherical (mean difference 0.00; 95% CI, −0.08 to 0.09; p = 0.93), and coma (mean difference −0.06; 95% CI, −0.14 to 0.03; p = 0.20) aberrations. Conclusions According to the meta-analysis, wavefront-guided PRK offered no advantage in efficacy, predictability, or safety measures over non-wavefront-guided PRK, although it may have induced fewer trefoil aberrations. PMID

  18. Outcome and safety of transrectal US-guided percutaneous cryotherapy for localized prostate cancer.

    PubMed

    Saliken, J C; Donnelly, B J; Brasher, P; Ali-Ridha, N; Ernst, S; Robinson, J

    1999-02-01

    To assess the effectiveness and safety of ultrasound (US)-guided cryotherapy as a primary treatment for localized prostate cancer. A prospective study of percutaneous transrectal US (TRUS)-guided cryotherapy was performed on 71 patients with T1-T3, N0, M0 prostatic cancer: 10 patients underwent two or more procedures. All cases were newly diagnosed and patients had no previous treatment for cancer. For all patients, TRUS biopsies were performed at 5-6 months. Patients were monitored at 6 weeks; 3, 6, 9, and 12 months; and twice yearly thereafter for prostate specific antigen (PSA) levels, complications, and clinical evidence of residual disease. Follow-up from 10 to 36 months was available for 70 of 71 patients; one patient died of unrelated disease. Initially, 10 of 69 patients had positive postcryotherapy biopsy results. After repeated treatment, nine of these 10 patients had negative biopsy results and one patient had no follow-up. Overall, 68 of 69 patients had negative biopsy results. At 1 year, 43 of 64 (67%) had an undetectable PSA level. Two patients had proven metastases. Complications include three cases with urethral sloughing requiring transurethral resection of the prostate (TURP). One patient had orchitis. Two patients had persistent incontinence, one as the result of a TURP. There was no death, acute serious morbidity, or fistula formation. Impotence was universal at 6 months, but many patients demonstrated late recovery. Cryoablation is an imaging-guided percutaneous intervention for prostate cancer that can safely yield disease-free status in a high percentage of patients with localized disease.

  19. Using quality and safety education for nurses to guide clinical teaching on a new dedicated education unit.

    PubMed

    McKown, Terri; McKeon, Leslie; McKown, Leslie; Webb, Sherry

    2011-12-01

    Gaps exist in health professional education versus the demands of current practice. Leveraging front-line nurses to teach students exemplary practice in a Dedicated Education Unit (DEU) may narrow this gap. The DEU is an innovative model for experiential learning, capitalizing on the expertise of staff nurses as clinical teachers. This study evaluated the effectiveness of a new academic-practice DEU in facilitating quality and safety competency achievement among students. Six clinical teachers received education in clinical teaching and use of Quality and Safety Education for Nurses (QSEN) competencies to guide acquisition of essential knowledge, skills, and attitudes for continuous health care improvement. Twelve students assigned to the six teachers completed daily logs for the 10-week practicum. Findings suggest that DEU students achieved QSEN competencies through clinical teacher mentoring in interdisciplinary collaboration, using electronic information for best practice and patient teaching, patient/family decision making, quality improvement, and resolution of safety issues.

  20. Arizona Traffic Safety Education, K-8. Pedestrian Safety, Grades K-1.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains thirteen lessons on pedestrian safety for use in kindergarten and grade 1. Introductory information provided for the teacher includes basic highway safety concepts, stressing…

  1. Rural expressway intersection safety toolbox : desktop reference.

    DOT National Transportation Integrated Search

    2011-06-01

    This document is intended to be a guide for planning-level decisions concerning safety : issues and subsequent potential improvements at rural expressway intersections. It is : NOT a design guide. It simply presents the gamut of safety treatment opti...

  2. Pocket guide to transportation, 2007

    DOT National Transportation Integrated Search

    2007-01-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) System Extent and Use, (2) Safety, (3) Security, (4) Mobility, (5) Economy, (6) Environment, and...

  3. Pocket guide to transportation, 2006

    DOT National Transportation Integrated Search

    2006-01-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) System Extent and Use, (2) Safety, (3) Security, (4) Mobility, (5) Economy, (6) Environment, and...

  4. Pocket guide to transportation, 2008

    DOT National Transportation Integrated Search

    2008-02-01

    The Bureau of Transportation Statistics compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) System Extent and Use, (2) Safety, (3) Security, (4) Mobility, (5) Economy, (6) Environment, and...

  5. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2013-01-01 2013-01-01 false Contents of applications; technical information in final...

  6. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2012-01-01 2012-01-01 false Contents of applications; technical information in final...

  7. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2014-01-01 2014-01-01 false Contents of applications; technical information in final...

  8. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2011-01-01 2011-01-01 false Contents of applications; technical information in final...

  9. Two-year clinical follow-up after pulmonary vein isolation using high-intensity focused ultrasound (HIFU) and an esophageal temperature-guided safety algorithm.

    PubMed

    Neven, Kars; Metzner, Andreas; Schmidt, Boris; Ouyang, Feifan; Kuck, Karl-Heinz

    2012-03-01

    High-intensity frequency ultrasound (HIFU) can achieve pulmonary vein isolation (PVI), but severe complications have happened. An esophageal temperature (ET)-guided safety algorithm was implemented. We investigated medium-term outcome. After left atrial access, HIFU was applied until complete PVI. The safety algorithm was as follows: ≤3 complete ablations per pulmonary vein, early abortion when ET ≥40.0°C, use of Power Modulation at ET >39.0°C or when after 20 to 30 seconds no change in PV electrograms: to reduce the ablation temperature in the surrounding tissue, acoustic power is switched on and off with a frequency of 1 Hz; in all first ablations, use of Power Modulation after 50% of programmed time. Touch-up radiofrequency ablation when PVI failed. Follow-up included interviews and Holter electrocardiograms. Recurrence was defined as atrial fibrillation (AF) >30 seconds without a blanking period. A total of 28 symptomatic patients (18 males, age 63 years), with paroxysmal AF (n = 19) and persistent AF (n = 9) were included. After a median follow-up of 738 days, 22 of the 28 patients (79%) were free of AF without antiarrhythmic drugs. After 1 repeat procedure with radiofrequency ablation, 5 patients remained free of AF. The complications were as follows: 1 lethal atrial-to-esophageal fistula at day 31, 1 pericardial effusion at day 48, 1 unexplained death at day 49, and 2 persistent phrenic nerve palsies with full recovery within 12 months. Two-year follow-up after PVI using HIFU and an ET-guided safety algorithm shows success rates similar to those of radiofrequency-based procedures but with higher complication rates. Importantly, the ET-guided safety algorithm failed to prevent severe complications. HIFU does not meet safety standards required for the treatment of AF, and this led to a halt of its clinical use. Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  10. 76 FR 51058 - Petitions for Modification of Application of Existing Mandatory Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ... CFR part 48 training plan to the Metal/ Nonmetal Safety and Health District Manager. In addition to... DEPARTMENT OF LABOR Mine Safety and Health Administration Petitions for Modification of Application of Existing Mandatory Safety Standards AGENCY: Mine Safety and Health Administration, Labor...

  11. Maintenance Safety Reader

    DTIC Science & Technology

    1991-02-01

    they’re called on to guide a vehicle. Stress that when guiding, they must stay clear of the vehicle and remain visible to the driver at all times...the ground guide’s safety by keeping the guide in sight at all times. Stress to your drivers that if they lose sight of their guide, even for a...bold arrows in bright colors so they can be seen and obtained quickly if a fire should start. Stress to your maintenance personnel that each one of them

  12. Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

    PubMed Central

    Li, Xiao-long; Lu, Feng; Yue, Wen-wen; Sun, Li-ping; Bo, Xiao-wan; Guo, Le-hang; Xu, Jun-mei; Liu, Bo-ji; Li, Dan-dan; Qu, Shen

    2016-01-01

    Objective: To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. Methods: The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150–T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. Results: In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47–16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510–17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. Conclusion: Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. Advances in knowledge: Based on the comparable efficacy and clinical

  13. The Ultimate Factor of Safety for Aircraft and Spacecraft Its History, Applications and Misconceptions

    NASA Technical Reports Server (NTRS)

    Zipay, John J.; Modlin, C. Thomas, Jr.; Larsen, Curtis E.

    2016-01-01

    The ultimate factor of safety (FOSULT) concept used in aircraft and spacecraft has evolved over many decades. Currently an FOSULT 1.5 is the FAR-mandated value for aircraft while an FOSULT of 1.4 has been used in various spacecraft. This paper was motivated by the desire to concisely explain the origins, proper interpretation and application of the ultimate factor of safety concept, since the authors have seen throughout their careers many misconceptions and incorrect applications of this concept. The history of the ultimate factor of safety concept is briefly summarized, the proper application of the factor of safety in aircraft design, structural analysis and operations is covered in detail, examples of limit load exceedance in aircraft and spacecraft are discussed, the evolution of the 1.4 FOSULT for spacecraft is described and some misconceptions regarding the ultimate factor of safety concept are addressed. It is hoped that this paper can be a summary resource for engineers to understand the origin, purpose and proper application of the ultimate factor of safety.

  14. 76 FR 69764 - Petitions for Modification of Application of Existing Mandatory Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-09

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration Petitions for Modification of Application of Existing Mandatory Safety Standards AGENCY: Mine Safety and Health Administration, Labor. ACTION: Notice. SUMMARY: Section 101(c) of the Federal Mine Safety and Health Act of 1977 and 30 CFR part...

  15. Apply Pesticides Correctly, A Guide for Commercial Applicators: Aquatic Pest Control.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide presents information needed to meet the requirements for pesticide applicator certification. The first part deals with recognition and control of aquatic pests such as aquatic weeds, fish and other vertebrates. Environmental concerns in aquatic pest control are discussed in the second section. (CS)

  16. Educating future leaders in patient safety

    PubMed Central

    Leotsakos, Agnès; Ardolino, Antonella; Cheung, Ronny; Zheng, Hao; Barraclough, Bruce; Walton, Merrilyn

    2014-01-01

    Education of health care professionals has given little attention to patient safety, resulting in limited understanding of the nature of risk in health care and the importance of strengthening systems. The World Health Organization developed the Patient Safety Curriculum Guide: Multiprofessional Edition to accelerate the incorporation of patient safety teaching into higher educational curricula. The World Health Organization Curriculum Guide uses a health system-focused, team-dependent approach, which impacts all health care professionals and students learning in an integrated way about how to operate within a culture of safety. The guide is pertinent in the context of global educational reforms and growing recognition of the need to introduce patient safety into health care professionals’ curricula. The guide helps to advance patient safety education worldwide in five ways. First, it addresses the variety of opportunities and contexts in which health care educators teach, and provides practical recommendations to learning. Second, it recommends shared learning by students of different professions, thus enhancing student capacity to work together effectively in multidisciplinary teams. Third, it provides guidance on a range of teaching methods and pedagogical activities to ensure that students understand that patient safety is a practical science teaching them to act in evidence-based ways to reduce patient risk. Fourth, it encourages supportive teaching and learning, emphasizing the need to establishing teaching environments in which students feel comfortable to learn and practice patient safety. Finally, it helps educators incorporate patient safety topics across all areas of clinical practice. PMID:25285012

  17. Overhead guide sign retroreflectivity and illumination.

    DOT National Transportation Integrated Search

    2015-01-01

    Roadway guide sign visibility during darkness is fundamental to driver safety, especially elderly drivers. Guide : sign visibility can be improved by external sign illumination or the use of retroreflective sheeting on signs. Because : energy conserv...

  18. Virtual Safety Training.

    ERIC Educational Resources Information Center

    Fuller, Scott; Davis, Jason

    2003-01-01

    The Multimedia Tool Box Talk is a web-based quick reference safety guide and training tool for construction personnel. An intended outcome of this effort was to provide an efficient and effective way to locate and interpret crucial safety information while at the job site. The tool includes information from the Occupational Safety and Health…

  19. Motorcycle Safety Education. A Curriculum Guide.

    ERIC Educational Resources Information Center

    Ohio State Board of Education, Columbus.

    This curriculum guide was produced to assist instructors of educational programs for novice motorcycle operators, automobile drivers, and all highway users. An introductory section discusses program implementation concerns, such as public relations, legal considerations, scheduling, staff, students, facilities, motorcycles, insurance, financial…

  20. Multimodality Image Fusion-Guided Procedures: Technique, Accuracy, and Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abi-Jaoudeh, Nadine, E-mail: naj@mail.nih.gov; Kruecker, Jochen, E-mail: jochen.kruecker@philips.com; Kadoury, Samuel, E-mail: samuel.kadoury@polymtl.ca

    2012-10-15

    Personalized therapies play an increasingly critical role in cancer care: Image guidance with multimodality image fusion facilitates the targeting of specific tissue for tissue characterization and plays a role in drug discovery and optimization of tailored therapies. Positron-emission tomography (PET), magnetic resonance imaging (MRI), and contrast-enhanced computed tomography (CT) may offer additional information not otherwise available to the operator during minimally invasive image-guided procedures, such as biopsy and ablation. With use of multimodality image fusion for image-guided interventions, navigation with advanced modalities does not require the physical presence of the PET, MRI, or CT imaging system. Several commercially available methodsmore » of image-fusion and device navigation are reviewed along with an explanation of common tracking hardware and software. An overview of current clinical applications for multimodality navigation is provided.« less

  1. Efficacy, acceptability and safety of guided imagery/hypnosis in fibromyalgia - A systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Zech, N; Hansen, E; Bernardy, K; Häuser, W

    2017-02-01

    This systematic review aimed at evaluating the efficacy, acceptability and safety of guided imagery/hypnosis (GI/H) in fibromyalgia. Cochrane Library, MEDLINE, PsycINFO and SCOPUS were screened through February 2016. Randomized controlled trials (RCTs) comparing GI/H with controls were analysed. Primary outcomes were ≥50% pain relief, ≥20% improvement of health-related quality of life, psychological distress, disability, acceptability and safety at end of therapy and 3-month follow-up. Effects were summarized by a random effects model using risk differences (RD) or standardized mean differences (SMD) with 95% confidence intervals (CI).Seven RCTs with 387 subjects were included into a comparison of GI/H versus controls. There was a clinically relevant benefit of GI/H compared to controls on ≥50% pain relief [RD 0.18 (95% CI 0.02, 0.35)] and psychological distress [SMD -0.40 (95% CI -0.70, -0.11)] at the end of therapy. Acceptability at the end of treatment for GI/H was not significantly different to the control. Two RCTs with 95 subjects were included in the comparison of hypnosis combined with cognitive behavioural therapy (CBT) versus CBT alone. Combined therapy was superior to CBT alone in reducing psychological distress at the end of therapy [SMD -0.50 (95% CI -0.91, -0.09)]. There were no statistically significant differences between combined therapy and CBT alone in other primary outcomes at the end of treatment and follow-up. No study reported on safety. GI/H hold promise in a multicomponent management of fibromyalgia. We provide a systematic review with meta-analysis on guided imagery and hypnosis for fibromyalgia. Current analyses endorse the efficacy and tolerability of guided imagery/hypnosis and of the combination of hypnosis with cognitive-behavioural therapy in reducing key symptoms of fibromyalgia. © 2016 European Pain Federation - EFIC®.

  2. [Application of Raman Spectroscopy Technique to Agricultural Products Quality and Safety Determination].

    PubMed

    Liu, Yan-de; Jin, Tan-tan

    2015-09-01

    The quality and safety of agricultural products and people health are inseparable. Using the conventional chemical methods which have so many defects, such as sample pretreatment, complicated operation process and destroying the samples. Raman spectroscopy as a powerful tool of analysing and testing molecular structure, can implement samples quickly without damage, qualitative and quantitative detection analysis. With the continuous improvement and the scope of the application of Raman spectroscopy technology gradually widen, Raman spectroscopy technique plays an important role in agricultural products quality and safety determination, and has wide application prospects. There have been a lot of related research reports based on Raman spectroscopy detection on agricultural product quality safety at present. For the understanding of the principle of detection and the current development situation of Raman spectroscopy, as well as tracking the latest research progress both at home and abroad, the basic principles and the development of Raman spectroscopy as well as the detection device were introduced briefly. The latest research progress of quality and safety determination in fruits and vegetables, livestock and grain by Raman spectroscopy technique were reviewed deeply. Its technical problems for agricultural products quality and safety determination were pointed out. In addition, the text also briefly introduces some information of Raman spectrometer and the application for patent of the portable Raman spectrometer, prospects the future research and application.

  3. Percutaneous CT-Guided Biopsies of the Cervical Spine: Technique, Histopathologic and Microbiologic Yield, and Safety at a Single Academic Institution.

    PubMed

    Wiesner, E L; Hillen, T J; Long, J; Jennings, J W

    2018-05-01

    Cervical spine biopsies can be challenging due to the anatomy and the adjacent critical structures. Percutaneous image-guided biopsies can obviate the need for an open biopsy, however there have been few studies looking at the approaches, safety, and efficacy of percutaneous cervical spine biopsies. This retrospective study evaluated technical considerations, histopathologic and microbiologic yield, and safety in CT-guided cervical bone biopsies. A retrospective review of cervical bone and/or bone/disc biopsies performed from January 2010 to January 2017 was included in this study. Clinical diagnosis and indication, patient demographics, biopsy location, biopsy needle type, technical approach, lesion size, dose-length product, conscious sedation details, complications, and diagnostic histopathologic and/or microbiologic yield were recorded for each case and summarized. A total of 73 patients underwent CT-guided cervical bone biopsies. Fifty-three percent (39/73) were for clinical/imaging concern for infection and 47% (34/73) were for primary tumors or metastatic disease. Thirty-four percent (25/73) were of the inferior cervical spine (ie, C6 and C7). A sufficient sample was obtained for histopathologic and microbiologic analyses in 96% (70/73) of the biopsies. Forty-six percent (18/39) of those samples taken for infection had positive cultures. Two intraprocedural complications occurred in which the patients became hypotensive during the procedure without long-term complications. Percutaneous CT-guided biopsy of the cervical spine is an effective and safe procedure with high diagnostic yield and can obviate open procedures for histopathologic and microbiologic analyses of patients with clinical and imaging findings concerning for infection or primary and metastatic osseous lesions. © 2018 by American Journal of Neuroradiology.

  4. Apply Pesticides Correctly, A Guide for Commercial Applicators: Right-of-Way Pest Control.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide contains basic information to meet specific standards for pesticide applicators. The text is concerned with the recognition of weeds and methods of their control in rights-of-way. Different types of application equipment both airborne and ground are discussed with precautions for the safe and effective use of herbicides. (CS)

  5. Safety on Earth From MARSS

    NASA Technical Reports Server (NTRS)

    2002-01-01

    ENSCO, Inc., developed the Meteorological and Atmospheric Real-time Safety Support (MARSS) system for real-time assessment of meteorological data displays and toxic material spills. MARSS also provides mock scenarios to guide preparations for emergencies involving meteorological hazards and toxic substances. Developed under a Small Business Innovation Research (SBIR) contract with Kennedy Space Center, MARSS was designed to measure how safe NASA and Air Force range safety personnel are while performing weather sensitive operations around launch pads. The system augments a ground operations safety plan that limits certain work operations to very specific weather conditions. It also provides toxic hazard prediction models to assist safety managers in planning for and reacting to releases of hazardous materials. MARSS can be used in agricultural, industrial, and scientific applications that require weather forecasts and predictions of toxic smoke movement. MARSS is also designed to protect urban areas, seaports, rail facilities, and airports from airborne releases of hazardous chemical substances. The system can integrate with local facility protection units and provide instant threat detection and assessment data that is reportable for local and national distribution.

  6. Computer Applications in Instruction: A Teacher's Guide to Selection and Use.

    ERIC Educational Resources Information Center

    Edwards, Judith B.; And Others

    Intended for upper elementary and secondary teachers in all subject areas, this guide provides practical advice on determining the appropriate application of computer technology and on the selection of specific, subject-related computer-based instruction units. Under the heading of hardware and software, topics discussed include communicating with…

  7. 29 CFR 500.130 - Application and scope of safety and health requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the aforesaid capacities. (d) The Occupational Safety and Health Administration (OSHA) is the agency of the U.S. Department of Labor which administers the Occupational Safety and Health Act (29 U.S.C... 29 Labor 3 2010-07-01 2010-07-01 false Application and scope of safety and health requirement. 500...

  8. Putting Safety in the Frame

    PubMed Central

    O’Keeffe, Valerie Jean; Thompson, Kirrilly Rebecca; Tuckey, Michelle Rae; Blewett, Verna Lesley

    2015-01-01

    Current patient safety policy focuses nursing on patient care goals, often overriding nurses’ safety. Without understanding how nurses construct work health and safety (WHS), patient and nurse safety cannot be reconciled. Using ethnography, we examine social contexts of safety, studying 72 nurses across five Australian hospitals making decisions during patient encounters. In enacting safe practice, nurses used “frames” built from their contextual experiences to guide their behavior. Frames are produced by nurses, and they structure how nurses make sense of their work. Using thematic analysis, we identify four frames that inform nurses’ decisions about WHS: (a) communicating builds knowledge, (b) experiencing situations guides decisions, (c) adapting procedures streamlines work, and (d) team working promotes safe working. Nurses’ frames question current policy and practice by challenging how nurses’ safety is positioned relative to patient safety. Recognizing these frames can assist the design and implementation of effective WHS management. PMID:28462311

  9. Trends in HFE Methods and Tools and Their Applicability to Safety Reviews

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, J.M.; Plott, C.; Milanski, J.

    2009-09-30

    The U.S. Nuclear Regulatory Commission's (NRC) conducts human factors engineering (HFE) safety reviews of applicant submittals for new plants and for changes to existing plants. The reviews include the evaluation of the methods and tools (M&T) used by applicants as part of their HFE program. The technology used to perform HFE activities has been rapidly evolving, resulting in a whole new generation of HFE M&Ts. The objectives of this research were to identify the current trends in HFE methods and tools, determine their applicability to NRC safety reviews, and identify topics for which the NRC may need additional guidance tomore » support the NRC's safety reviews. We conducted a survey that identified over 100 new HFE M&Ts. The M&Ts were assessed to identify general trends. Seven trends were identified: Computer Applications for Performing Traditional Analyses, Computer-Aided Design, Integration of HFE Methods and Tools, Rapid Development Engineering, Analysis of Cognitive Tasks, Use of Virtual Environments and Visualizations, and Application of Human Performance Models. We assessed each trend to determine its applicability to the NRC's review by considering (1) whether the nuclear industry is making use of M&Ts for each trend, and (2) whether M&Ts reflecting the trend can be reviewed using the current design review guidance. We concluded that M&T trends that are applicable to the commercial nuclear industry and are expected to impact safety reviews may be considered for review guidance development. Three trends fell into this category: Analysis of Cognitive Tasks, Use of Virtual Environments and Visualizations, and Application of Human Performance Models. The other trends do not need to be addressed at this time.« less

  10. 76 FR 15046 - Office of Hazardous Materials Safety; Notice of Applications for Modification of Special Permit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Applications for Modification of Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: List of applications for modification of...

  11. Safe laser application requires more than laser safety

    NASA Astrophysics Data System (ADS)

    Frevel, A.; Steffensen, B.; Vassie, L.

    1995-02-01

    An overview is presented concerning aspects of laser safety in European industrial laser use. Surveys indicate that there is a large variation in the safety strategies amongst industrial laser users. Some key problem areas are highlighted. Emission of hazardous substances is a major problem for users of laser material processing systems where the majority of the particulate is of a sub-micrometre size, presenting a respiratory hazard. Studies show that in many cases emissions are not frequently monitored in factories and uncertainty exists over the hazards. Operators of laser machines do not receive adequate job training or safety training. The problem is compounded by a plethora of regulations and standards which are difficult to interpret and implement, and inspectors who are not conversant with the technology or the issues. A case is demonstrated for a more integrated approach to laser safety, taking into account the development of laser applications, organizational and personnel development, in addition to environmental and occupational health and safety aspects. It is necessary to achieve a harmonization between these elements in any organization involved in laser technology. This might be achieved through establishing technology transfer centres in laser technology.

  12. Machine Trades Lab Management Guide.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Instructional Materials Lab.

    This manual was developed to guide machine trades instructors and vocational supervisors in sequencing laboratory instruction and controlling the flow of work for a 2-year machine trades training program. The first part of the guide provides information on program management (program description, safety concerns, academic issues, implementation…

  13. Zone guide for pedestrian safety

    DOT National Transportation Integrated Search

    2008-12-01

    Just as communities can efficiently mount crime prevention programs by focusing them in high-crime areas, they can also efficiently concentrate pedestrian safety improvements by carefully selecting where they are applied. To do this, they need to be ...

  14. An Evaluation Tool for Agricultural Health and Safety Mobile Applications.

    PubMed

    Reyes, Iris; Ellis, Tammy; Yoder, Aaron; Keifer, Matthew C

    2016-01-01

    As the use of mobile devices and their software applications, or apps, becomes ubiquitous, use amongst agricultural working populations is expanding as well. The smart device paired with a well-designed app has potential for improving workplace health and safety in the hands of those who can act upon the information provided. Many apps designed to assess workplace hazards and implementation of worker protections already exist. However, the abundance and diversity of such applications also presents challenges regarding evaluation practices and assignation of value. This is particularly true in the agricultural workspace, as there is currently little information on the value of these apps for agricultural safety and health. This project proposes a framework for developing and evaluating apps that have potential usefulness in agricultural health and safety. The evaluation framework is easily transferable, with little modification for evaluation of apps in several agriculture-specific areas.

  15. Transcranial MR-Guided Focused Ultrasound: A Review of the Technology and Neuro Applications

    PubMed Central

    Ghanouni, Pejman; Pauly, Kim Butts; Elias, W. Jeff; Henderson, Jaimie; Sheehan, Jason; Monteith, Stephen; Wintermark, Max

    2015-01-01

    MR guided focused ultrasound is a new, minimally invasive method of targeted tissue thermal ablation that may be of use to treat central neuropathic pain, essential tremor, Parkinson tremor, and brain tumors. The system has also been used to temporarily disrupt the blood-brain barrier to allow targeted drug delivery to brain tumors. This article reviews the physical principles of MR guided focused ultrasound and discusses current and potential applications of this exciting technology. PMID:26102394

  16. 77 FR 46797 - Notice of Fiscal Year 2013 Safety Grants and Solicitation for Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-06

    ... emphasis on texting and hand-held cell phone prohibitions, work zone enforcement, rural road safety, and... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration Notice of Fiscal Year 2013 Safety Grants and Solicitation for Applications AGENCY: Federal Motor Carrier Safety...

  17. Radio-Frequency Applications for Food Processing and Safety.

    PubMed

    Jiao, Yang; Tang, Juming; Wang, Yifen; Koral, Tony L

    2018-03-25

    Radio-frequency (RF) heating, as a thermal-processing technology, has been extending its applications in the food industry. Although RF has shown some unique advantages over conventional methods in industrial drying and frozen food thawing, more research is needed to make it applicable for food safety applications because of its complex heating mechanism. This review provides comprehensive information regarding RF-heating history, mechanism, fundamentals, and applications that have already been fully developed or are still under research. The application of mathematical modeling as a useful tool in RF food processing is also reviewed in detail. At the end of the review, we summarize the active research groups in the RF food thermal-processing field, and address the current problems that still need to be overcome.

  18. Applying health education theory to patient safety programs: three case studies.

    PubMed

    Gilkey, Melissa B; Earp, Jo Anne L; French, Elizabeth A

    2008-04-01

    Program planning for patient safety is challenging because intervention-oriented surveillance data are not yet widely available to those working in this nascent field. Even so, health educators are uniquely positioned to contribute to patient safety intervention efforts because their theoretical training provides them with a guide for designing and implementing prevention programs. This article demonstrates the utility of applying health education concepts from three prominent patient safety campaigns, including the concepts of risk perception, community participation, and social marketing. The application of these theoretical concepts to patient safety programs suggests that health educators possess a knowledge base and skill set highly relevant to patient safety and that their perspective should be increasingly brought to bear on the design and evaluation of interventions that aim to protect patients from preventable medical error.

  19. Arizona Traffic Safety Education, K-8. Passenger Safety, Grade 2.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains eight lessons for use in grade 2. Introductory information provided for the teacher includes basic highway safety concepts, stressing communication methods for highway users,…

  20. Measure Guideline: Guide to Attic Air Sealing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    2014-09-01

    The purpose of this measure guideline is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy, health, safety, and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to themore » work that needs to be done.« less

  1. Apply Pesticides Correctly, A Guide for Commercial Applicators: Agricultural Pest Control -- Animal.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide contains basic information to meet specific standards for pesticide applicators. The text is concerned with the common pests of agricultural animals such as flies, ticks, bots, lice and mites. Methods for controlling these pests and appropriate pesticides are discussed. (CS)

  2. Safety in Riding Programs: A Director's Guide.

    ERIC Educational Resources Information Center

    Kpachavi, Teresa

    1996-01-01

    Camp riding programs should be examined regularly for liability and risk management issues. Elements of a basic safety assessment include requiring proper safety apparel, removing obstructions from riding rings, ensuring doors and gates are closed, requiring use of lead ropes, securing equine medications, banning smoking, posting written…

  3. Curriculum Guide for Electronics in Technology Education.

    ERIC Educational Resources Information Center

    Connecticut Industrial Technology Association.

    Consistent with the principles of the Connecticut Common Core of Learning, this competency-based curriculum guide for electronics provides a reference guide for educators to research and prepare for teaching the field of electronics. The guide contains 22 units that cover the following topics: theory of matter; safety; direct current; magnetism;…

  4. Arizona Traffic Safety Education, K-8. Bicycle Safety, Grade 2.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains ten lessons on bicycles for use in grade 2. Introductory information provided for the teacher includes basic highway safety concepts, stressing communication methods for highway users,…

  5. Arizona Traffic Safety Education, K-8. Bicycle Safety, Grade 3.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide for grade 3 contains seven lessons on bicycles and an appendix on conducting a bicycle rodeo. Introductory information provided for the teacher includes basic highway safety concepts, stressing…

  6. BASINs and WEPP Climate Assessment Tools (CAT): Case Study Guide to Potential Applications (Final Report)

    EPA Science Inventory

    EPA announced the release of the final report, BASINs and WEPP Climate Assessment Tools (CAT): Case Study Guide to Potential Applications. This report supports application of two recently developed water modeling tools, the Better Assessment Science Integrating point & ...

  7. Dental Radiology I Student Guide [and Instructor Guide].

    ERIC Educational Resources Information Center

    Fox Valley Technical Coll., Appleton, WI.

    The dental radiology student and instructor guides provide instruction in the following units: (1) x-ray physics; (2) x-ray production; (3) radiation health and safety; (4) radiographic anatomy and pathology; (5) darkroom setup and chemistry; (6) bisecting angle technique; (7) paralleling technique; (8) full mouth survey technique--composition and…

  8. Fit, Healthy, and Ready To Learn: A School Health Policy Guide. Part II: Policies To Promote Sun Safety and Prevent Skin Cancer.

    ERIC Educational Resources Information Center

    Fraser, Katherine

    This publication is a supplementary chapter to "Fit, Healthy, and Ready to Learn: A School Health Policy Guide; Part I: General School Health Policies, Physical Activity, Healthy Eating, and Tobacco-Use Prevention." It discusses various aspects of a complete school policy and plan to promote sun safety. The first section "Purpose…

  9. Connected commercial vehicles — retrofit safety device kit project : applications performance and functional test report.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  10. Acceptable Use Policies in a Web 2.0 & Mobile Era: A Guide for School Districts

    ERIC Educational Resources Information Center

    Consortium for School Networking (NJ1), 2011

    2011-01-01

    Web 2.0 applications and mobile Internet devices have added new issues to the safety/access situation for schools. The purpose of this guide is to assist school districts in developing, rethinking, or revising Internet policies as a consequence of the emergence of Web 2.0, and the growing pervasiveness of smart phone use. The Consortium for School…

  11. Packaging and Transportation Safety

    DOT National Transportation Integrated Search

    1997-01-31

    This Guide supplements the Department of Energy (DOE) Order, DOE O 460.1A, PACKAGING AND TRANSPORTATION SAFETY, 10-2-96, by providing clarifying material for the implementation of packaging and transportation safety of hazardous materials. DOE O 460....

  12. Safety Characteristics in System Application Software for Human Rated Exploration

    NASA Technical Reports Server (NTRS)

    Mango, E. J.

    2016-01-01

    NASA and its industry and international partners are embarking on a bold and inspiring development effort to design and build an exploration class space system. The space system is made up of the Orion system, the Space Launch System (SLS) and the Ground Systems Development and Operations (GSDO) system. All are highly coupled together and dependent on each other for the combined safety of the space system. A key area of system safety focus needs to be in the ground and flight application software system (GFAS). In the development, certification and operations of GFAS, there are a series of safety characteristics that define the approach to ensure mission success. This paper will explore and examine the safety characteristics of the GFAS development.

  13. [Preliminary safety and stability assessment of orthodontic miniscrew implantation guided by surgical template based on cone-beam CT images].

    PubMed

    Qiu, L L; Li, S; Bai, Y X

    2016-06-01

    To develop surgical templates for orthodontic miniscrew implantation based on cone-beam CT(CBCT)three-dimensional(3D)images and to evaluate the safety and stability of implantation guided by the templates. DICOM data obtained in patients who had CBCT scans taken were processed using Mimics software, and 3D images of teeth and maxillary bone were acquired. Meanwhile, 3D images of miniscrews were acquired using Solidworks software and processed with Mimics software. Virtual position of miniscrews was determined based on 3D images of teeth, bone, and miniscrews. 3D virtual templates were designed according to the virtual implantation plans. STL files were output and the real templates were fabricated with stereolithographic appliance(SLA). Postoperative CBCT scans were used to evaluate the implantation safety and the stability of miniscrews were investigated. All the templates were positioned accurately and kept stable throughout the implantation process. No root damage was found. The deviations were(1.73±0.65)mm at the corona, and(1.28±0.82)mm at the apex, respectively. The stability of miniscrews was fairly well. Surgical templates for miniscrew implantation could be acquired based on 3D CBCT images and fabricated with SLA. Implantation guided by these templates was safe and stable.

  14. Arizona Traffic Safety Education, K-8. Passenger Safety, Grades K-1.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains nine lessons for use in kindergarten and grade 1. Introductory information provided for the teacher includes basic highway safety concepts, stressing communication methods for highway…

  15. Experience with specifications applicable to certification. [of photovoltaic modules for large-scale application

    NASA Technical Reports Server (NTRS)

    Ross, R. G., Jr.

    1982-01-01

    The Jet Propulsion Laboratory has developed a number of photovoltaic test and measurement specifications to guide the development of modules toward the requirements of future large-scale applications. Experience with these specifications and the extensive module measurement and testing that has accompanied their use is examined. Conclusions are drawn relative to three aspects of product certification: performance measurement, endurance testing and safety evaluation.

  16. 75 FR 45677 - Draft Regulatory Guide, DG-1216,”Plant-Specific Applicability of Transition Break Size Specified...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-03

    ... NUCLEAR REGULATORY COMMISSION [NRC-2010-0229] Draft Regulatory Guide, DG-1216,''Plant-Specific... Commission (NRC) is extending the public comment period for DG-1216 from August 25, 2010 to November 8, 2010... [email protected] . The Draft Regulatory Guide, DG-1216, ``Plant- Specific Applicability of...

  17. Aluminum Data Measurements and Evaluation for Criticality Safety Applications

    NASA Astrophysics Data System (ADS)

    Leal, L. C.; Guber, K. H.; Spencer, R. R.; Derrien, H.; Wright, R. Q.

    2002-12-01

    The Defense Nuclear Facility Safety Board (DNFSB) Recommendation 93-2 motivated the US Department of Energy (DOE) to develop a comprehensive criticality safety program to maintain and to predict the criticality of systems throughout the DOE complex. To implement the response to the DNFSB Recommendation 93-2, a Nuclear Criticality Safety Program (NCSP) was created including the following tasks: Critical Experiments, Criticality Benchmarks, Training, Analytical Methods, and Nuclear Data. The Nuclear Data portion of the NCSP consists of a variety of differential measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) at the Oak Ridge National Laboratory (ORNL), data analysis and evaluation using the generalized least-squares fitting code SAMMY in the resolved, unresolved, and high energy ranges, and the development and benchmark testing of complete evaluations for a nuclide for inclusion into the Evaluated Nuclear Data File (ENDF/B). This paper outlines the work performed at ORNL to measure, evaluate, and test the nuclear data for aluminum for applications in criticality safety problems.

  18. Arizona Traffic Safety Education, K-8. Bicycle Safety, Grades K-1.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic safety skills, this curriculum guide contains nine lessons on sidewalk vehicles and bicycles for use in kindergarten and grade 1. Introductory information provided for the teacher includes basic highway safety concepts, stressing…

  19. Safety in the Chemical Laboratory

    ERIC Educational Resources Information Center

    Steere, Norman V.

    1969-01-01

    Presents the Safety Guide used in the Research Center at Monsanto Chemical Company (St. Louis). Topics include: general safety practices, safety glasses and shoes, respiratory protection, electrical wiring, solvent handling and waste disposal. Procedures are given for evacuating, "tagging out, and "locking out. Special mention is given to…

  20. 75 FR 40023 - Notice of Fiscal Year 2011 Safety Grants and Solicitation for Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-13

    ... safety agencies. For grants awarded for public education activities, the Federal share will be 100... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [FMCSA Docket No. FMCSA-2010-0212] Notice of Fiscal Year 2011 Safety Grants and Solicitation for Applications AGENCY: Federal...

  1. Application of the QSDC procedure to the formulation of space shuttle design criteria. Volume 2: Applications guide

    NASA Technical Reports Server (NTRS)

    Bouton, I.; Martin, G. L.

    1972-01-01

    Criteria to determine the probability of aircraft structural failure were established according to the Quantitative Structural Design Criteria by Statistical Methods, the QSDC Procedure. This criteria method was applied to the design of the space shuttle during this contract. An Applications Guide was developed to demonstrate the utilization of the QSDC Procedure, with examples of the application to a hypothetical space shuttle illustrating the application to specific design problems. Discussions of the basic parameters of the QSDC Procedure: the Limit and Omega Conditions, and the strength scatter, have been included. Available data pertinent to the estimation of the strength scatter have also been included.

  2. V-TECS Guide for Cosmetology (Cosmetologists).

    ERIC Educational Resources Information Center

    Gregory, Margaret R.; Benson, Robert T.

    This curriculum guide is intended to train trade and industrial education students in the hands-on aspects of the occupation of cosmetologist. Included in the guide are course outlines that address the following topics: following safety and sanitation procedures in managing a salon; shampooing, conditioning, cutting, and styling hair; permanent…

  3. The Food-Safe Schools Action Guide

    ERIC Educational Resources Information Center

    Centers for Disease Control and Prevention, 2007

    2007-01-01

    "The Food-Safe School Needs Assessment and Planning Guide" is a tool that can help schools assess their food safety policies, procedures, and programs and develop plans for improvement. This tool includes a simple, straightforward questionnaire, score card, and planning guide that give administrators, school staff, families, and students a chance…

  4. Bicycle Safety, Grades K-6. Experimental Curriculum Bulletin.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Div. of Curriculum and Instruction.

    This experimental curriculum guide for bicycle safety begins with a chapter listing vehicle and traffic laws pertaining to bicycling. Chapter 2 of the guide is organized by grade level. Appropriate lesson plans for bicycle safety are presented with aims, concepts activities and behavioral objectives. A 24-item list of activities summarizes these…

  5. Applications of aerospace technology in industry, a technology transfer profile: Fire safety

    NASA Technical Reports Server (NTRS)

    Kottenstette, J. P.; Freeman, J. E.; Heins, C. R.; Hildred, W. M.; Johnson, F. D.; Staskin, E. R.

    1971-01-01

    The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined.

  6. The International Safety Framework for nuclear power source applications in outer space-Useful and substantial guidance

    NASA Astrophysics Data System (ADS)

    Summerer, L.; Wilcox, R. E.; Bechtel, R.; Harbison, S.

    2015-06-01

    In 2009, the International Safety Framework for Nuclear Power Source Applications in Outer Space was adopted, following a multi-year process that involved all major space faring nations under the auspices of a partnership between the UN Committee on the Peaceful Uses of Outer Space and the International Atomic Energy Agency. The Safety Framework reflects an international consensus on best practices to achieve safety. Following the 1992 UN Principles Relevant to the Use of Nuclear Power Sources in Outer Space, it is the second attempt by the international community to draft guidance promoting the safety of applications of nuclear power sources in space missions. NPS applications in space have unique safety considerations compared with terrestrial applications. Mission launch and outer space operational requirements impose size, mass and other space environment limitations not present for many terrestrial nuclear facilities. Potential accident conditions could expose nuclear power sources to extreme physical conditions. The Safety Framework is structured to provide guidance for both the programmatic and technical aspects of safety. In addition to sections containing specific guidance for governments and for management, it contains technical guidance pertinent to the design, development and all mission phases of space NPS applications. All sections of the Safety Framework contain elements directly relevant to engineers and space mission designers for missions involving space nuclear power sources. The challenge for organisations and engineers involved in the design and development processes of space nuclear power sources and applications is to implement the guidance provided in the Safety Framework by integrating it into the existing standard space mission infrastructure of design, development and operational requirements, practices and processes. This adds complexity to the standard space mission and launch approval processes. The Safety Framework is deliberately

  7. 30 CFR 75.1429 - Guide ropes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guide ropes. 75.1429 Section 75.1429 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY... minimum value calculated as follows: Minimum value=Static Load×5.0. ...

  8. The Application of Software Safety to the Constellation Program Launch Control System

    NASA Technical Reports Server (NTRS)

    Kania, James; Hill, Janice

    2011-01-01

    The application of software safety practices on the LCS project resulted in the successful implementation of the NASA Software Safety Standard NASA-STD-8719.138 and CxP software safety requirements. The GOP-GEN-GSW-011 Hazard Report was the first report developed at KSC to identify software hazard causes and their controls. This approach can be applied to similar large software - intensive systems where loss of control can lead to a hazard.

  9. Light-Guided Surface Engineering for Biomedical Applications

    PubMed Central

    Jayagopal, Ashwath; Stone, Gregory P.; Haselton, Frederick R.

    2010-01-01

    Free radical species generated through fluorescence photobleaching have been reported to effectively couple a water-soluble species to surfaces containing electron-rich sites (1). In this report, we expand upon this strategy to control the patterned attachment of antibodies and peptides to surfaces for biosensing and tissue engineering applications. In the first application, we compare hydrophobic attachment and photobleaching methods to immobilize FITC-labeled anti-M13K07 bacteriophage antibodies to the SiO2 layer of a differential capacitive biosensor and to the polyester filament of a feedback-controlled filament array. On both surfaces, antibody attachment and function were superior to the previously employed hydrophobic attachment. Furthermore, a laser scanning confocal microscope could be used for automated, software-guided photoattachment chemistry. In a second application, the cell-adhesion peptide RGDS was site-specifically photocoupled to glass coated with fluorescein-conjugated poly(ethylene glycol). RGDS attachment and bioactivity were characterized by a fibroblast adhesion assay. Cell adhesion was limited to sites of RGDS photocoupling. These examples illustrate that fluorophore-based photopatterning can be achieved by both solution-phase fluorophores or surface-adhered fluorophores. The coupling preserves the bioactivity of the patterned species, is amenable to a variety of surfaces, and is readily accessible to laboratories with fluorescence imaging equipment. The flexibility offered by visible light patterning will likely have many useful applications in bioscreening and tissue engineering where the controlled placement of biomolecules and cells is critical, and should be considered as an alternative to chemical coupling methods. PMID:18314938

  10. GUIDE-Seq enables genome-wide profiling of off-target cleavage by CRISPR-Cas nucleases

    PubMed Central

    Nguyen, Nhu T.; Liebers, Matthew; Topkar, Ved V.; Thapar, Vishal; Wyvekens, Nicolas; Khayter, Cyd; Iafrate, A. John; Le, Long P.; Aryee, Martin J.; Joung, J. Keith

    2014-01-01

    CRISPR RNA-guided nucleases (RGNs) are widely used genome-editing reagents, but methods to delineate their genome-wide off-target cleavage activities have been lacking. Here we describe an approach for global detection of DNA double-stranded breaks (DSBs) introduced by RGNs and potentially other nucleases. This method, called Genome-wide Unbiased Identification of DSBs Enabled by Sequencing (GUIDE-Seq), relies on capture of double-stranded oligodeoxynucleotides into breaks Application of GUIDE-Seq to thirteen RGNs in two human cell lines revealed wide variability in RGN off-target activities and unappreciated characteristics of off-target sequences. The majority of identified sites were not detected by existing computational methods or ChIP-Seq. GUIDE-Seq also identified RGN-independent genomic breakpoint ‘hotspots’. Finally, GUIDE-Seq revealed that truncated guide RNAs exhibit substantially reduced RGN-induced off-target DSBs. Our experiments define the most rigorous framework for genome-wide identification of RGN off-target effects to date and provide a method for evaluating the safety of these nucleases prior to clinical use. PMID:25513782

  11. Independent evaluation of light-vehicle safety applications based on vehicle-to-vehicle communications used in the 2012-2013 safety pilot model deployment

    DOT National Transportation Integrated Search

    2015-12-01

    This report presents the methodology and results of the independent evaluation of safety applications for passenger vehicles in the 2012-2013 Safety Pilot Model Deployment, part of the United States Department of Transportations Intelligent Transp...

  12. Safety and Health Training Resources.

    ERIC Educational Resources Information Center

    Federal Safety Advisory Council, Washington, DC.

    Information obtained from a survey of safety and health training activities undertaken by Federal agencies is provided in the document which serves as a resource guide and directory of agency safety programs. The document, intended to help Federal managers meet their safety training needs with available government resources, is divided into four…

  13. A Bibliographic Guide to Occupational Safety and Health.

    ERIC Educational Resources Information Center

    Pease, Sue

    1981-01-01

    Lists government publications, periodicals, loose-leaf services, reports, and reference materials dealing with health and safety in the work environment. Addresses for the Occupational Safety and Health Administration regional offices are provided. (FM)

  14. NHTSA data reference guide version 4. Volume 3, component tests

    DOT National Transportation Integrated Search

    1997-04-01

    This guide documents the format of magnetic media (3.5 inch high density diskettes) to be submitted : to the National Highway Traffic Safety Administration (NHTSA) for component tests. This guide is : designated Volume III. NHTSA Data Reference Guide...

  15. Controlling exposure to chemicals: a simple guide.

    PubMed

    Hay, Alastair

    2006-09-01

    Controlling exposure to chemicals in the workplace has been made easier by the use of a guide published by the U.K. Health and Safety Executive (HSE). Known as COSHH (Control of Substances Hazardous to Health Regulations) Essentials, the guide is a simple five-step procedure to devise appropriate control strategies to reduce exposures to various substances under different conditions. U.K. health and safety law requires risk assessments prior to use of hazardous substances and installation of appropriate control strategies before work commences. A 1996 survey of 1500 safety managers and trade union safety representatives revealed that the majority had little understanding of occupational safety limits for chemicals. Small- and medium-sized companies had little understanding of limits, and most could not develop control strategies. A new approach was required. COSHH Essentials is it. Developed over 3 years by a working group of hygienists and toxicologists representing HSE, industry, trade unions, and independent experts, the guide is now available in both paper-based and internet versions. It applies a hazard banding approach validated by data for 111 substances that have well-founded U.K. occupational exposure limits. New users select an appropriate hazard band for chemicals based on risk phrases. Details about dustiness for powders or volatility for liquids are inserted, and the guide allocates substances to one of four exposure bands linked, in turn, to specific control strategies. Now accessible through the HSE web site, COSHH Essentials will offer control strategies for both single chemicals and whole processes. To date over 300,000 risk assessments have been carried out using the internet version of COSHH Essentials.

  16. Safety and licensing of a small modular gas-cooled reactor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, N.W.; Kelley, A.P. Jr.

    A modular side-by-side high-temperature gas-cooled reactor (SBS-HTGR) is being developed by Interatom/Kraftwerk Union (KWU). The General Electric Company and Interatom/KWU entered into a proprietary working agreement to continue develop jointly of the SBS-HTGR. A study on adapting the SBS-HTGR for application in the US has been completed. The study investigated the safety characteristics and the use of this type of design in an innovative approach to licensing. The safety objective guiding the design of the modular SBS-HTGR is to control radionuclide release by the retention of fission products within the fuel particles with minimal reliance on active design features. Themore » philosophy on which this objective is predicated is that by providing a simple safety case, the safety criteria can be demonstrated as being met with high confidence through conduct of a full-scale module safety test.« less

  17. Radiation safety standards and their application: international policies and current issues.

    PubMed

    González, Abel J

    2004-09-01

    This paper briefly describes the current policies of the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection and how these policies are converted into international radiation safety standards by the International Atomic Energy Agency, which is the only global organization-within the United Nations family of international agencies-with a statutory mandate not only to establish such standards but also to provide for their application. It also summarizes the current status of the established corpus of such international standards, and of it foreseeable evolution, as well as of legally binding undertakings by countries around the world that are linked to these standards. Moreover, this paper also reviews some major current global issues related to the application of international standards, including the following: strengthening of national infrastructures for radiation safety, including technical cooperation programs for assisting developing countries; occupational radiation safety challenges, including the protection of pregnant workers and their unborn children, dealing with working environments with high natural radiation levels, and occupational attributability of health effects (probability of occupational causation); restricting discharges of radioactive substances into the environment: reviewing current international policies vis-a-vis the growing concern on the radiation protection of the "environment;" radiological protection of patients undergoing radiodiagnostic and radiotherapeutic procedures: the current International Action Plan; safety and security of radiation sources: post-11 September developments; preparedness and response to radiation emergencies: enhancing the international network; safe transport of radioactive materials: new apprehensions; safety of radioactive waste management: concerns and connections with radiation protection; and radioactive residues remaining

  18. 77 FR 71031 - Office of Hazardous Materials Safety; Actions on Special Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-28

    ...), transportation in commerce 173.465(d). of certain Radioactive material in alternative packaging by highway. A... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Actions on Special Permit Applications AGENCY: Pipeline And Hazardous Materials...

  19. Irregular Astigmatism After Corneal Transplantation--Efficacy and Safety of Topography-Guided Treatment.

    PubMed

    Laíns, Inês; Rosa, Andreia M; Guerra, Marta; Tavares, Cristina; Lobo, Conceição; Silva, Maria F L; Quadrado, Maria J; Murta, Joaquim N

    2016-01-01

    To analyze the efficacy and safety of topography-guided photorefractive keratectomy (TG-PRK) to treat irregular astigmatism after corneal transplantation. This was a retrospective observational case series. Eyes with irregular astigmatism after penetrating keratoplasty treated with TG-PRK (Allegretto Wave Eye-Q) with the topography-guided customized ablation treatment protocol were included. All treatments had been planned to correct the topographic irregularities, as well as to reduce the refractive error after neutralizing the induced refractive change. Clinical records, treatment plan, and the examinations performed were reviewed and the following data were collected: corrected and uncorrected distance visual acuities; manifest refraction; topographic parameters, and corneal endothelial cell count. We included 31 eyes [30 patients; mean age 45.0 ± 13.4 (SD) years]. At the last postoperative follow-up (mean 9.2 ± 8.2 months), we observed a significant improvement in corrected (P = 0.001) and uncorrected distance visual acuities (P < 0.001). There was a gain of ≥1 uncorrected distance visual acuity line in 96.8% (n = 30) of the eyes. Similarly, the refractive parameters also improved (cylinder P < 0.001; spherical equivalent P = 0.002). At the last visit, 54.8% (n = 17) of the patients presented a spherical equivalent of ±1 D. The 3-mm topographic irregularity also decreased significantly (P < 0.001). There was no significant variation of the corneal endothelial cell count. This is the largest case series of TG-PRK to treat irregular astigmatism in postcorneal transplantation eyes. Our results confirm that TG-PRK is an efficient treatment, associated with significant improvements of both visual acuity and refractive parameters.

  20. Community Living Skills Guide: Beginning Woodworking.

    ERIC Educational Resources Information Center

    Miller, Steve; Smith, Don

    This is one of twenty course guides in the Community Living Skills Guide for the College for Living series which provides guidelines and workbook activities for the course, Beginning Woodworking, Use of Basic Hand Tools and Shop Safety. The series of courses for developmentally disabled adults is intended to supplement residential programs and to…

  1. Computed tomography-guided percutaneous microwave ablation of hepatocellular carcinoma in challenging locations: safety and efficacy of high-power microwave platforms.

    PubMed

    Filippiadis, Dimitrios K; Spiliopoulos, Stavros; Konstantos, Chrysostomos; Reppas, Lazaros; Kelekis, Alexis; Brountzos, Elias; Kelekis, Nikolaos

    2017-09-03

    To evaluate the clinical efficacy/safety of CT-guided percutaneous microwave ablation for HCC in challenging locations using high-power microwave platforms. A retrospective review was conducted in 26 patients with 36 HCC tumours in challenging locations (hepatic dome, subcapsular, close to the heart/diaphragm/hepatic hilum, exophytic) undergoing CT-guided percutaneous microwave ablation in a single centre since January 2011. Two different microwave platforms were used both operating at 2.45 GHz: AMICA and Acculis MWA System. Patient demographics including age, sex, tumour size and location, as well as technical details were recorded. Technical success, treatment response, patients survival and complication rate were evaluated. Treated tumours were located in the hepatic dome (n = 14), subcapsularly (n = 16), in proximity to the heart (n = 2) or liver hilum (n = 2), while two were exophytic tumours at segment VI (n = 2). Mean tumour diameter was 3.30 cm (range 1.4-5 cm). In 3/26 patients (diameter >4 cm), an additional session of DEB-TACE was performed due to tumour size. Technical success rate was 100%; complete response rate was recorded in 33/36 tumours (91.6%). According to Kaplan-Meier analysis, survival rate was 92.3% and 72.11% at 24- and 60-month follow-up, respectively. There were no major complications; two cases of minor pneumothorax and two cases of small subcapsular haematoma were resolved only with observation requiring no further treatment. CT-guided percutaneous microwave ablation for hepatocellular carcinoma tumours in challenging locations and up to 5 cm in diameter can be performed with high efficacy and safety rates.

  2. Drafting Fundamentals. Drafting Module 1. Instructor's Guide.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Instructional Materials Lab.

    This Missouri Vocational Instruction Management System instructor's drafting guide has been keyed to the drafting competency profile developed by state industry and education professionals. The guide contains a cross-reference table of instructional materials. Ten units cover drafting fundamentals: (1) introduction to drafting; (2) general safety;…

  3. Overview of Design, Lifecycle, and Safety for Computer-Based Systems

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo

    2015-01-01

    This document describes the need and justification for the development of a design guide for safety-relevant computer-based systems. This document also makes a contribution toward the design guide by presenting an overview of computer-based systems design, lifecycle, and safety.

  4. CSPP CDX Registration Guide

    EPA Pesticide Factsheets

    CDX allows users submitting data to the EPA to register for the specific program of interest. This Guide describes the registration process and information requirements associated with Submissions for the Chemical Safety and Pesticide Programs (CSPP).

  5. Safety on the Job. Some Guidelines for Working Safely. Instructor's Edition.

    ERIC Educational Resources Information Center

    Oklahoma State Dept. of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.

    This teacher's guide was developed to help teachers (especially in Oklahoma) promote safe practices on the job. As a supplement to existing programs in the requirements for job safety, this book can also promote same basic safety attitudes and help support basic safety concepts, with an emphasis on accident prevention. The guide contains eight…

  6. Safety System Design for Technology Education. A Safety Guide for Technology Education Courses K-12.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh. Div. of Vocational Education.

    This manual is designed to involve both teachers and students in planning and controlling a safety system for technology education classrooms. The safety program involves students in the design and maintenance of the system by including them in the analysis of the classroom environment, job safety analysis, safety inspection, and machine safety…

  7. An Operational Safety and Certification Assessment of a TASAR EFB Application

    NASA Technical Reports Server (NTRS)

    Koczo, Stefan; Wing, David

    2013-01-01

    This paper presents an overview of a Traffic Aware Strategic Aircrew Requests (TASAR) Electronic Flight Bag application intended to inform the pilot of trajectory improvement opportunities while en route that result in operational benefits. The results of safety analyses and a detailed review of Federal Aviation Administration (FAA) regulatory documents that establish certification and operational approval requirements are presented for TASAR. The safety analyses indicate that TASAR has a likely Failure Effects Classification of “No Effect,” and at most, is no worse than “Minor Effect.” Based on this safety assessment and the detailed review of FAA regulatory documents that determine certification and operational approval requirements, this study concludes that TASAR can be implemented in the flight deck as a Type B software application hosted on a Class 2 Portable Electronic Device (PED) Electronic Flight Bag (EFB). This implementation approach would provide a relatively low-cost path to certification and operational approval for both retrofit and forward fit implementation, while at the same time facilitating the business case for early ADS-B IN equipage. A preliminary review by FAA certification and operational approvers of the analyses presented here confirmed that the conclusions are appropriate and that TASAR will be considered a Type B application.

  8. [Efficacy and safety of ultrasound-guided or neurostimulator-guided bilateral axillary brachial plexus block].

    PubMed

    Xu, C S; Zhao, X L; Zhou, H B; Qu, Z J; Yang, Q G; Wang, H J; Wang, G

    2017-10-17

    Objective: To explore the efficacy and safety of bilateral axillary brachial plexus block under the guidance of ultrasound or neurostimulator. Methods: From February 2012 to April 2014, 120 patients undergoing bilateral hand/forearm surgery in Beijing Jishuitan Hospital were enrolled and anaesthetized with bilateral axillary brachial plexus block. All patients were divided into two groups randomly using random number table: the ultrasound-guided group (group U, n =60) and the neurostimulator-guidedgroup (group N, n =60). The block was performed with 0.5% ropivacaine. Patients' age, sex and operation duration were recorded. Moreover, success rate, performance time, onset of sensor and motor block, performance pain, patient satisfaction degree and the incidence of related complications were also documented. Venous samples were collected at selected time points and the total and the plasma concentrations of ropivacaine were analyzed with HPLC. Results: The performance time, the onset of sensor block and the onset of motor block of group U were (8.2±1.5), (14.2± 2.2)and (24.0±3.5)min respectively, which were markedly shorter than those in group N( (14.6±3.9), (19.9±3.8), (28.8±4.2)min, respectively), and the differences were statistically significant( t =11.74, 10.09, 6.73, respectively, all P <0.01). The performance pain score of group N was (25.5± 13.2), which was obviously more serious than group U (31.7± 11.2) and a significant statistical difference was detected ( t =2.856, P <0.05). The patient satisfaction degree of group U was 95.0%, which was significantly higher than group N (83.3%) and a markedly statistical difference was detected (χ(2)=4.227, P <0.05). Fifty min after performance, the total plasma concentration of ropivacaine of group U was(1.76±0.48)mg/L, which was significantly lower than group N (1.88±0.53)mg/L and a significant statistical difference was detected ( t =2.43, P <0.05), while no significant differences were detected at the

  9. V-TECS Guide for Machine Shop (Machinist).

    ERIC Educational Resources Information Center

    Gregory, Margaret R.; Benson, Robert T.

    This curriculum guide is intended to train trade and industrial education students in the hands-on aspects of the occupation of machinist. Included in the guide are course outlines that deal with the following topics: following safety procedures; performing mathematical calculations; designing and planning machine work; performing precision…

  10. 30 CFR 57.19019 - Guide ropes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guide ropes. 57.19019 Section 57.19019 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... rope at installation shall meet the minimum value calculated as follows: Minimum value=Static Load×5.0. ...

  11. Introductory guide to CVISN

    DOT National Transportation Integrated Search

    1999-05-01

    This guide is designed to provide state administrators of motor carrier programs with information on safety, credentials, fuel tax and size and weight regulation as part of the Commercial Vehicle Information Systems and Networks (CVISN) Program. It d...

  12. EPA QUICK REFERENCE GUIDES

    EPA Science Inventory

    EPA Quick Reference Guides are compilations of information on chemical and biological terrorist agents. The information is presented in consistent format and includes agent characteristics, release scenarios, health and safety data, real-time field detection, effect levels, samp...

  13. AQUATOX Setup Guide

    EPA Pesticide Factsheets

    The new Guidance in AQUATOX Setup and Application provides a quick start guide to introduce major model features, as well as being a type of cookbook to guide basic model setup, calibration, and validation.

  14. Washington State Traffic Safety Education Curriculum Guide. A Master Guide for Implementing a Performance-Based Curriculum.

    ERIC Educational Resources Information Center

    Washington Office of the State Superintendent of Public Instruction, Olympia. Div. of Vocational-Technical and Adult Education Services.

    This guide for implementing performance-based curriculum is intended to teach students decision-making driving. Heavy emphasis is put on the tasks and concepts involving traffic flow tasks (interacting with other highway users) and the functions and factors that affect that interaction. It is a "90-hour" guide, that is, the average student needs…

  15. MO-DE-202-01: Image-Guided Focused Ultrasound Surgery and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farahani, K.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41

  16. Magnetically-Guided Penetrant Applicator

    NASA Technical Reports Server (NTRS)

    Molina, Orlando G.

    1990-01-01

    Small wheeled vehicle moved inside nonmagnetic enclosure. Miniature magnetically guided truck uses foam-rubber sponge pads to apply penetrant fluid for inspection of welds in hidden surfaces of nonmagnetic tubes. Risk of explosion less than if electric motor used to drive vehicle. Inexpensive to make and made in range of sizes.

  17. DOE standard 3009 - a reasoned, practical approach to integrating criticality safety into SARs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vessard, S.G.

    1995-12-31

    In the past there have been efforts by the U.S. Department of Energy (DOE) to provide guidance on those elements that should be included in a facility`s safety analysis report (SAR). In particular, there are two DOE Orders (5480.23, {open_quotes}Nuclear Safety Analysis Reports,{close_quotes} and 5480.24, {open_quotes}Nuclear Criticality Safety{close_quotes}), an interpretive guidance document (NE-70, Interpretive Guidance for DOE Order 5480.24, {open_quotes}Nuclear Criticality Safety{close_quotes}), and DOE Standard DOE-STD-3009-94 {open_quotes}Preparation Guide for U.S. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports.{close_quotes} Of these, the most practical and useful (pertaining to the application of criticality safety) is DOE-STD-3009-94. This paper is a reviewmore » of Chapters 3, 4, and 6 of this standard and how they provide very clear, helpful, and reasoned criticality safety guidance.« less

  18. Safety Precautions for Science.

    ERIC Educational Resources Information Center

    Folks, John; And Others

    Safety information is discussed and outlined in this guide. Areas include: (1) general laboratory safety rules; (2) general rules and guidelines for animals in the elementary classroom; (3) general guidelines for the physical sciences; (4) general rules for using animals in investigations, with specifics on the care and handling of mammals,…

  19. Workplace Health and Safety.

    ERIC Educational Resources Information Center

    Massachusetts Career Development Inst., Springfield.

    This booklet is one of six texts from a workplace literacy curriculum designed to assist learners in facing the increased demands of the workplace. It is a short guide to workplace health and safety issues, laws, and regulations, especially in Massachusetts. Topics covered include the following: (1) safety issues--workplace ergonomics, the…

  20. Kids Guide to Shots

    MedlinePlus

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body ... Safe Videos for Educators Search English Español A Kid's Guide to Shots KidsHealth / For Kids / A Kid's ...

  1. Kid's Guide to Fever

    MedlinePlus

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body ... Safe Videos for Educators Search English Español A Kid's Guide to Fever KidsHealth / For Kids / A Kid's ...

  2. V-TECS Guide for Auto Body Repair.

    ERIC Educational Resources Information Center

    Gregory, Margaret R.; Benson, Robert T.

    This curriculum guide consists of materials for teaching a course in auto body repair. Addressed in the individual units of the guide are the following topics: the nature and scope of auto body repair; safety; tools; auto body construction; simple metal straightening; welding; painting and refinishing; refinishing complete lacquer; refinishing…

  3. Swimming Pools. Managing School Facilities, Guide 2.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This guide for schools with swimming pools offers advice concerning appropriate training for pool managers, the importance of water quality and testing, safety in the handling of chemicals, maintenance and cleaning requirements, pool security, and health concerns. The guide covers both indoor and outdoor pools, explains some technical terms,…

  4. Measure Guideline: Guide to Attic Air Sealing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, J.

    2014-09-01

    The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guidemore » is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.« less

  5. Assessment of the SonixGPS system for its application in real-time ultrasonography navigation-guided percutaneous nephrolithotomy for the treatment of complex kidney stones.

    PubMed

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; He, Hui

    2017-04-01

    SonixGPS is a novel real-time ultrasonography navigation technology, which has been demonstrated to promote accuracy of puncture in surgical operations. The aim of this study is to evaluate its application in guiding the puncture during percutaneous nephrolithotomy (PCNL). We retrospectively reviewed our experience in treating a total of 74 patients with complex kidney stones with PCNL, in which puncture in 37 cases were guided by SonixGPS system, while the other 37 by conventional ultrasound. The effectiveness of operation was evaluated in terms of stone clearance rate, operation time, time to successful puncture, number of attempts for successful puncture and hospital stay. The safety of operation was examined by evaluating postoperative complications. Our retrospective review showed that although there were no significant differences in stone clearance rates between the groups, SonixGPS guidance resulted in more puncture accuracy with shorter puncture time and higher successful puncture rate. Under the help of SonixGPS, most patients (92 %) had no or just mild complications, compared to that (73 %) in conventional ultrasound group. Post-operative decrease of hemoglobin in SonixGPS group was 13.79 (7-33) mg/dl, significantly lower than that 20.97 (8-41) mg/dl in conventional ultrasound group. Our experience demonstrates that SonixGPS is superior to conventional ultrasound in guiding the puncture in PCNL for the treatment of complex kidney stone.

  6. Effects of the Smartphone Application "Safe Patients" on Knowledge of Patient Safety Issues Among Surgical Patients.

    PubMed

    Cho, Sumi; Lee, Eunjoo

    2017-12-01

    Recently, the patient's role in preventing adverse events has been emphasized. Patients who are more knowledgeable about safety issues are more likely to engage in safety initiatives. Therefore, nurses need to develop techniques and tools that increase patients' knowledge in preventing adverse events. For this reason, an educational smartphone application for patient safety called "Safe Patients" was developed through an iterative process involving a literature review, expert consultations, and pilot testing of the application. To determine the effect of "Safe Patients," it was implemented for patients in surgical units in a tertiary hospital in South Korea. The change in patients' knowledge about patient safety was measured using seven true/false questions developed in this study. A one-group pretest and posttest design was used, and a total of 123 of 190 possible participants were tested. The percentage of correct answers significantly increased from 64.5% to 75.8% (P < .001) after implementation of the "Safe Patients" application. This study demonstrated that the application "Safe Patients" could effectively improve patients' knowledge of safety issues. This will ultimately empower patients to engage in safe practices and prevent adverse events related to surgery.

  7. Illinois Pesticide Applicator Study Guide. A Training Manual for Private and Commercial Pesticide Applicators and Operators. Special Publication 39.

    ERIC Educational Resources Information Center

    Bever, Wayne; And Others

    This study guide is designed to provide the necessary information to prepare for certification as a private or commercial pesticide applicator. In addition to providing basic information covering the various sections of the amended Federal Insecticide, Fungicide, and Rodenticide Act, it contains a glossary of common pesticide terms, a list of…

  8. Towards an Ultrasonic Guided Wave Procedure for Health Monitoring of Composite Vessels: Application to Hydrogen-Powered Aircraft

    PubMed Central

    Yaacoubi, Slah; McKeon, Peter; Ke, Weina; Declercq, Nico F.; Dahmene, Fethi

    2017-01-01

    This paper presents an overview and description of the approach to be used to investigate the behavior and the defect sensitivity of various ultrasonic guided wave (UGW) modes propagating specifically in composite cylindrical vessels in the framework of the safety of hydrogen energy transportation such as hydrogen-powered aircrafts. These structures which consist of thick and multi-layer composites are envisioned for housing hydrogen gas at high pressures. Due to safety concerns associated with a weakened structure, structural health monitoring techniques are needed. A procedure for optimizing damage detection in these structural types is presented. It is shown that a finite element method can help identify useful experimental parameters including frequency range, excitation type, and receiver placement. PMID:28925961

  9. Illumination of interior spaces by bended hollow light guides: Application of the theoretical light propagation method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Darula, Stanislav; Kocifaj, Miroslav; Kittler, Richard

    2010-12-15

    To ensure comfort and healthy conditions in interior spaces the thermal, acoustics and daylight factors of the environment have to be considered in the building design. Due to effective energy performance in buildings the new technology and applications also in daylight engineering are sought such as tubular light guides. These allow the transport of natural light into the building core reducing energy consumption. A lot of installations with various geometrical and optical properties can be applied in real buildings. The simplest set of tubular light guide consists of a transparent cupola, direct tube with high reflected inner surface and amore » ceiling cover or diffuser redistributing light into the interior. Such vertical tubular guide is often used on flat roofs. When the roof construction is inclined a bend in the light guide system has to be installed. In this case the cupola is set on the sloped roof which collects sunlight and skylight from the seen part of the sky hemisphere as well as that reflected from the ground and opposite facades. In comparison with the vertical tube some additional light losses and distortions of the propagated light have to be expected in bended tubular light guides. Recently the theoretical model of light propagation was already published and its applications are presented in this study solving illuminance distributions on the ceiling cover interface and further illuminance distribution on the working plane in the interior. (author)« less

  10. Pocket guide to large truck and bus statistics, 2015.

    DOT National Transportation Integrated Search

    2015-04-01

    The Federal Motor Carrier Safety Administration compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) Overview: Large Trucks and Buses, (2) Roadside Inspections and Violations, (3) Reviews, ...

  11. Pocket guide to large trucks and bus statistics, 2014.

    DOT National Transportation Integrated Search

    2014-10-01

    The Federal Motor Carrier Safety Administration compiled the data in this guide from multiple sources. The guide is divided into six sections and a glossary: (1) Overview: Large Trucks and Buses, (2) Roadside Inspections and Violations, (3) Reviews, ...

  12. Criticality Safety Basics for INL FMHs and CSOs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    V. L. Putman

    2012-04-01

    Nuclear power is a valuable and efficient energy alternative in our energy-intensive society. However, material that can generate nuclear power has properties that require this material be handled with caution. If improperly handled, a criticality accident could result, which could severely harm workers. This document is a modular self-study guide about Criticality Safety Principles. This guide's purpose it to help you work safely in areas where fissionable nuclear materials may be present, avoiding the severe radiological and programmatic impacts of a criticality accident. It is designed to stress the fundamental physical concepts behind criticality controls and the importance of criticalitymore » safety when handling fissionable materials outside nuclear reactors. This study guide was developed for fissionable-material-handler and criticality-safety-officer candidates to use with related web-based course 00INL189, BEA Criticality Safety Principles, and to help prepare for the course exams. These individuals must understand basic information presented here. This guide may also be useful to other Idaho National Laboratory personnel who must know criticality safety basics to perform their assignments safely or to design critically safe equipment or operations. This guide also includes additional information that will not be included in 00INL189 tests. The additional information is in appendices and paragraphs with headings that begin with 'Did you know,' or with, 'Been there Done that'. Fissionable-material-handler and criticality-safety-officer candidates may review additional information at their own discretion. This guide is revised as needed to reflect program changes, user requests, and better information. Issued in 2006, Revision 0 established the basic text and integrated various programs from former contractors. Revision 1 incorporates operation and program changes implemented since 2006. It also incorporates suggestions, clarifications, and additional

  13. Apply Pesticides Correctly, A Guide for Commercial Applicators: Ornamental and Turfgrass Pest Control.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide contains basic information to meet specific standards for pesticide applicators. The text is concerned with recognition and control of ornamental and turfgrass pests such as leaf spot, scab, powdery mildew, galls, grubs and weeds. A section of the text is also devoted to environmental concerns to be considered when undertaking pest…

  14. Getting Students in the Safety Zone

    ERIC Educational Resources Information Center

    Roy, Ken

    2010-01-01

    Students coming into science labs need initial and ongoing training about safety standards and best practices. They also need to develop good attitudes about their work and the health and safety of their teachers and fellow students. The "School Chemistry Laboratory Safety Guide" is a resource for science teachers and school administrators to help…

  15. Percutaneous Image-guided Radiofrequency Ablation of Tumors in Inoperable Patients - Immediate Complications and Overall Safety.

    PubMed

    Sahay, Anubha; Sahay, Nishant; Kapoor, Ashok; Kapoor, Jyoti; Chatterjee, Abhishek

    2016-01-01

    Percutaneous destruction of cancer cells using a radiofrequency energy source has become an accepted part of the modern armamentarium for managing malignancies. Radiofrequency ablation (RFA) is a relatively novel procedure for treating recurrent and metastatic tumors. It is used for debulking tumors and as adjuvant therapy for palliative care apart from its role as a pain management tool. Its use in the third world countries is limited by various factors such as cost and expertise. In the remotest parts of India, where economic development has been slow, abject poverty with poor health care facilities advanced malignancies present a challenge to health care providers. We undertook this study to assess the safety of the percutaneous RFA tumor ablation as a therapeutic or palliative measure in patients where surgery was not possible. We observed that RFA may be an effective, alternative therapeutic modality for some inoperable tumors where other therapeutic modalities cannot be considered. Palliative and therapeutic image-guided RFAs of tumors may be the only treatment option in patients who are inoperable for a variety of reasons. To assess the safety and complications of RFA in such a patient population is important before embarking upon any interventions given their physically, mentally, and socially compromised status in a country such as India. To assess the safety of percutaneous image-guided radiofrequency tumor ablation and to note the various immediate and early complications of the intervention. This was a prospective, observational study conducted in Tata Main Hospital, Jamshedpur, Jharkhand, India. After approval by the Hospital Approval Committee all patients who consented for percutaneous RFA of their tumor admitted in the hospital were included after taking fully informed consent from patient/close relative keeping the following criteria in view. Patients who were likely to derive a direct benefit in the survival or as a palliative measure for relief

  16. Praedicere Possumus: An Italian web-based application for predictive microbiology to ensure food safety.

    PubMed

    Polese, Pierluigi; Torre, Manuela Del; Stecchini, Mara Lucia

    2018-03-31

    The use of predictive modelling tools, which mainly describe the response of microorganisms to a particular set of environmental conditions, may contribute to a better understanding of microbial behaviour in foods. In this paper, a tertiary model, in the form of a readily available and userfriendly web-based application Praedicere Possumus (PP) is presented with research examples from our laboratories. Through the PP application, users have access to different modules, which apply a set of published models considered reliable for determining the compliance of a food product with EU safety criteria and for optimising processing throughout the identification of critical control points. The application pivots around a growth/no-growth boundary model, coupled with a growth model, and includes thermal and non-thermal inactivation models. Integrated functionalities, such as the fractional contribution of each inhibitory factor to growth probability (f) and the time evolution of the growth probability (P t ), have also been included. The PP application is expected to assist food industry and food safety authorities in their common commitment towards the improvement of food safety.

  17. Willingness to use mobile application for smartphone for improving road safety.

    PubMed

    Cardamone, Angelo Stephen; Eboli, Laura; Forciniti, Carmen; Mazzulla, Gabriella

    2016-01-01

    In the last few years mobile devices have reached a large amount of consumers in both developed and high-growth world economies. In 2013, 97% of the Italian population owns a mobile phone, and 62% owns a smartphone. Application software for mobile devices is largely proposed to consumers, and several mobile applications were oriented toward the improvement of road safety and road accident risk reduction. In this paper, we describe the results of a survey oriented to preventively investigate on the willingness to receive and/or to give information about road condition by means of mobile devices. Road users were informed about the characteristics of a mobile application, and then they were invited to complete a questionnaire. Experimental data were used for capturing road user attitudes toward the use of the smartphone to improve road safety, and to establish the preferences for the different features of the proposed mobile application. To this end, we choose to use the ordered probit model methodology. We demonstrate that the adopted methodology accounts for the differential impacts of the willingness to receive and/or to give information about road conditions on the overall willingness to receive and/or to give information through an application software for mobile devices.

  18. 76 FR 77589 - Office of Hazardous Materials Safety; Notice of Application for Special Permits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-13

    ... DC. commerce of radioactive materials without being subject to the requirements in 49 CFR 173.417(a... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Application for Special Permits AGENCY: Pipeline and Hazardous...

  19. 77 FR 36607 - Office of Hazardous Materials Safety Notice of Application for Special Permits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... commerce of certain DOT Specification 20WC radioactive material packagings after October 1, 2008. (mode 1... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety Notice of Application for Special Permits AGENCY: Pipeline and Hazardous...

  20. Construction safety in DOE. Part 1, Students guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Handwerk, E C

    This report is the first part of a compilation of safety standards for construction activities on DOE facilities. This report covers the following areas: general safety and health provisions; occupational health and environmental control/haz mat; personal protective equipment; fire protection and prevention; signs, signals, and barricades; materials handling, storage, use, and disposal; hand and power tools; welding and cutting; electrical; and scaffolding.

  1. Wildlife in Today's Landscapes. Leader's/Teacher's Guide L-5-20.

    ERIC Educational Resources Information Center

    Krasny, Marianne E.

    This illustrated teacher's guide provides background and activities for helping youths aged 12 and older to understand basic wildlife biology and ecology. The first of the guide's five chapters is an introduction explaining the purpose and format of the guide, addressing safety and responsibility issues, and defining several terms and concepts…

  2. Transit vehicle-to-infrastructure (V2I) applications : near term research and development transit bus stop pedestrian safety application : operational concept.

    DOT National Transportation Integrated Search

    2014-12-01

    This document serves as an Operational Concept for the Transit Bus Stop Pedestrian Safety application. The purpose of this document is to communicate user needs and desired capabilities for and expectations of the Transit Bus Stop Pedestrian Safety a...

  3. MRI-guided brachytherapy

    PubMed Central

    Tanderup, Kari; Viswanathan, Akila; Kirisits, Christian; Frank, Steven J.

    2014-01-01

    The application of MRI-guided brachytherapy has demonstrated significant growth during the last two decades. Clinical improvements in cervix cancer outcomes have been linked to the application of repeated MRI for identification of residual tumor volumes during radiotherapy. This has changed clinical practice in the direction of individualized dose administration, and mounting evidence of improved clinical outcome with regard to local control, overall survival as well as morbidity. MRI-guided prostate HDR and LDR brachytherapy has improved the accuracy of target and organs-at-risk (OAR) delineation, and the potential exists for improved dose prescription and reporting for the prostate gland and organs at risk. Furthermore, MRI-guided prostate brachytherapy has significant potential to identify prostate subvolumes and dominant lesions to allow for dose administration reflecting the differential risk of recurrence. MRI-guided brachytherapy involves advanced imaging, target concepts, and dose planning. The key issue for safe dissemination and implementation of high quality MRI-guided brachytherapy is establishment of qualified multidisciplinary teams and strategies for training and education. PMID:24931089

  4. Safety leadership: application in construction site.

    PubMed

    Cooper, Dominic

    2010-01-01

    The extant safety literature suggests that managerial Safety Leadership is vital to the success and maintenance of a behavioral safety process. The current paper explores the role of Managerial Safety Leadership behaviors in the success of a behavioral safety intervention in the Middle-East with 47,000 workers from multiple nationalities employed by fourteen sub-contractors and one main contractor. A quasi-experimental repeating ABABAB, within groups design was used. Measurement focused on managerial Safety Leadership and employee safety behaviors as well as Corrective Actions. Data was collected over 104 weeks. During this time, results show safety behavior improved by 30 percentage points from an average of 65% during baseline to an average of 95%. The site achieved 121 million man-hours free of lost-time injuries on the longest run. Stepwise multiple regression analyses indicated 86% of the variation in employee safety behavior was associated with senior, middle and front-line manager's Safety Leadership behaviors and the Corrective Action Rate. Approximately 38% of the variation in the Total Recordable Incident Rate (TRIR) was associated with the Observation rate, Corrective Action Rate and Observers Records of managerial safety leaders (Visible Ongoing Support). The results strongly suggest manager's Safety Leadership influences the success of Behavioral Safety processes.

  5. LABORATORY DESIGN CONSIDERATIONS FOR SAFETY.

    ERIC Educational Resources Information Center

    National Safety Council, Chicago, IL. Campus Safety Association.

    THIS SET OF CONSIDERATIONS HAS BEEN PREPARED TO PROVIDE PERSONS WORKING ON THE DESIGN OF NEW OR REMODELED LABORATORY FACILITIES WITH A SUITABLE REFERENCE GUIDE TO DESIGN SAFETY. THERE IS NO DISTINCTION BETWEEN TYPES OF LABORATORY AND THE EMPHASIS IS ON GIVING GUIDES AND ALTERNATIVES RATHER THAN DETAILED SPECIFICATIONS. AREAS COVERED INCLUDE--(1)…

  6. Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses

    PubMed Central

    Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao

    2018-01-01

    Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650

  7. Experiment Design and Analysis Guide - Neutronics & Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Misti A Lillo

    2014-06-01

    The purpose of this guide is to provide a consistent, standardized approach to performing neutronics/physics analysis for experiments inserted into the Advanced Test Reactor (ATR). This document provides neutronics/physics analysis guidance to support experiment design and analysis needs for experiments irradiated in the ATR. This guide addresses neutronics/physics analysis in support of experiment design, experiment safety, and experiment program objectives and goals. The intent of this guide is to provide a standardized approach for performing typical neutronics/physics analyses. Deviation from this guide is allowed provided that neutronics/physics analysis details are properly documented in an analysis report.

  8. [Experience of Fusion image guided system in endonasal endoscopic surgery].

    PubMed

    Wen, Jingying; Zhen, Hongtao; Shi, Lili; Cao, Pingping; Cui, Yonghua

    2015-08-01

    To review endonasal endoscopic surgeries aided by Fusion image guided system, and to explore the application value of Fusion image guided system in endonasal endoscopic surgeries. Retrospective research. Sixty cases of endonasal endoscopic surgeries aided by Fusion image guided system were analysed including chronic rhinosinusitis with polyp (n = 10), fungus sinusitis (n = 5), endoscopic optic nerve decompression (n = 16), inverted papilloma of the paranasal sinus (n = 9), ossifying fibroma of sphenoid bone (n = 1), malignance of the paranasal sinus (n = 9), cerebrospinal fluid leak (n = 5), hemangioma of orbital apex (n = 2) and orbital reconstruction (n = 3). Sixty cases of endonasal endoscopic surgeries completed successfully without any complications. Fusion image guided system can help to identify the ostium of paranasal sinus, lamina papyracea and skull base. Fused CT-CTA images, or fused MR-MRA images can help to localize the optic nerve or internal carotid arteiy . Fused CT-MR images can help to detect the range of the tumor. It spent (7.13 ± 1.358) minutes for image guided system to do preoperative preparation and the surgical navigation accuracy reached less than 1mm after proficient. There was no device localization problem because of block or head set loosed. Fusion image guided system make endonasal endoscopic surgery to be a true microinvasive and exact surgery. It spends less preoperative preparation time, has high surgical navigation accuracy, improves the surgical safety and reduces the surgical complications.

  9. Ultrasound-guided versus fluoroscopy-guided sacroiliac joint intra-articular injections in the noninflammatory sacroiliac joint dysfunction: a prospective, randomized, single-blinded study.

    PubMed

    Jee, Haemi; Lee, Ji-Hae; Park, Ki Deok; Ahn, Jaeki; Park, Yongbum

    2014-02-01

    To compare the short-term effects and safety of ultrasound (US)-guided sacroiliac joint (SIJ) injections with fluoroscopy (FL)-guided SIJ injections in patients with noninflammatory SIJ dysfunction. Prospective, randomized controlled trial. University hospital. Patients (N=120) with noninflammatory sacroiliac arthritis were enrolled. All procedures were performed using an FL or US apparatus. Subjects were randomly assigned to either the FL or US group. Immediately after the SIJ injections, fluoroscopy was applied to verify the correct placement of the injected medication and intravascular injections. Treatment effects and functional improvement were compared at 2 and 12 weeks after the procedures. The verbal numeric pain scale and Oswestry Disability Index improved at 2 and 12 weeks after the injections without statistical significances between groups. Of 55 US-guided injections, 48 (87.3%) were successful and 7 (12.7%) were missed. The FL-guided SIJ approach exhibited a greater accuracy (98.2%) than the US-guided approach. Vascularization around the SIJ was seen in 34 of 55 patients. Among the 34 patients, 7 had vascularization inside the joint, 23 had vascularization around the joint, and 4 had vascularization both inside and around the joint. Three cases of intravascular injections occurred in the FL group. The US-guided approach may facilitate the identification and avoidance of the critical vessels around or within the SIJ. Function and pain relief significantly improved in both groups without significant differences between groups. The US-guided approach was shown to be as effective as the FL-guided approach in treatment effects. However, diagnostic application in the SIJ may be limited because of the significantly lower accuracy rate (87.3%). Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  10. The automatic neutron guide optimizer guide_bot

    NASA Astrophysics Data System (ADS)

    Bertelsen, Mads

    2017-09-01

    The guide optimization software guide_bot is introduced, the main purpose of which is to reduce the time spent programming when performing numerical optimization of neutron guides. A limited amount of information on the overall guide geometry and a figure of merit describing the desired beam is used to generate the code necessary to solve the problem. A generated McStas instrument file performs the Monte Carlo ray-tracing, which is controlled by iFit optimization scripts. The resulting optimal guide is thoroughly characterized, both in terms of brilliance transfer from an idealized source and on a more realistic source such as the ESS Butterfly moderator. Basic MATLAB knowledge is required from the user, but no experience with McStas or iFit is necessary. This paper briefly describes how guide_bot is used and some important aspects of the code. A short validation against earlier work is performed which shows the expected agreement. In addition a scan over the vertical divergence requirement, where individual guide optimizations are performed for each corresponding figure of merit, provides valuable data on the consequences of this parameter. The guide_bot software package is best suited for the start of an instrument design project as it excels at comparing a large amount of different guide alternatives for a specific set of instrument requirements, but is still applicable in later stages as constraints can be used to optimize more specific guides.

  11. NHTSA data reference guide version 4. Volume 4, signal waveform generator tests

    DOT National Transportation Integrated Search

    1997-09-01

    This guide documents the format of magnetic media (3.5 inch high density diskettes) to be submitted : to the National Highway Traffic Safety Administration (NHTSA) for SWG tests. This guide is : designated Volume IV. NHTSA Data Reference Guide (Signa...

  12. Computational Modeling for Enhancing Soft Tissue Image Guided Surgery: An Application in Neurosurgery.

    PubMed

    Miga, Michael I

    2016-01-01

    With the recent advances in computing, the opportunities to translate computational models to more integrated roles in patient treatment are expanding at an exciting rate. One area of considerable development has been directed towards correcting soft tissue deformation within image guided neurosurgery applications. This review captures the efforts that have been undertaken towards enhancing neuronavigation by the integration of soft tissue biomechanical models, imaging and sensing technologies, and algorithmic developments. In addition, the review speaks to the evolving role of modeling frameworks within surgery and concludes with some future directions beyond neurosurgical applications.

  13. Safety Education Handbook. Volume 2.

    ERIC Educational Resources Information Center

    Kansas State Dept. of Education, Topeka.

    This is the second of three volumes of a safety guide developed to assist Kansas administrators and teachers in organizing, evaluating, and maintaining safety programs. It provides information to help them identify, assess, and correct unsafe conditions relating to equipment and facilities and ensure a safe and healthy environment for themselves…

  14. Safety Education Handbook. Volume 3.

    ERIC Educational Resources Information Center

    Kansas State Dept. of Education, Topeka.

    This is the third of three volumes of a safety guide developed to assist Kansas administrators and teachers in organizing, evaluating, and maintaining safety programs. It provides information to help them identify, assess, and correct unsafe conditions relating to equipment and facilities and ensure a safe and healthy environment for themselves…

  15. Commonalities and Differences in Functional Safety Systems Between ISS Payloads and Industrial Applications

    NASA Astrophysics Data System (ADS)

    Malyshev, Mikhail; Kreimer, Johannes

    2013-09-01

    Safety analyses for electrical, electronic and/or programmable electronic (E/E/EP) safety-related systems used in payload applications on-board the International Space Station (ISS) are often based on failure modes, effects and criticality analysis (FMECA). For industrial applications of E/E/EP safety-related systems, comparable strategies exist and are defined in the IEC-61508 standard. This standard defines some quantitative criteria based on potential failure modes (for example, Safe Failure Fraction). These criteria can be calculated for an E/E/EP system or components to assess their compliance to requirements of a particular Safety Integrity Level (SIL). The standard defines several SILs depending on how much risk has to be mitigated by a safety-critical system. When a FMECA is available for an ISS payload or its subsystem, it may be possible to calculate the same or similar parameters as defined in the 61508 standard. One example of a payload that has a dedicated functional safety subsystem is the Electromagnetic Levitator (EML). This payload for the ISS is planned to be operated on-board starting 2014. The EML is a high-temperature materials processing facility. The dedicated subsystem "Hazard Control Electronics" (HCE) is implemented to ensure compliance to failure tolerance in limiting samples processing parameters to maintain generation of the potentially toxic by-products to safe limits in line with the requirements applied to the payloads by the ISS Program. The objective of this paper is to assess the implementation of the HCE in the EML against criteria for functional safety systems in the IEC-61508 standard and to evaluate commonalities and differences with respect to safety requirements levied on ISS Payloads. An attempt is made to assess a possibility of using commercially available components and systems certified for compliance to industrial functional safety standards in ISS payloads.

  16. Towards a Food Safety Knowledge Base Applicable in Crisis Situations and Beyond.

    PubMed

    Falenski, Alexander; Weiser, Armin A; Thöns, Christian; Appel, Bernd; Käsbohrer, Annemarie; Filter, Matthias

    2015-01-01

    In case of contamination in the food chain, fast action is required in order to reduce the numbers of affected people. In such situations, being able to predict the fate of agents in foods would help risk assessors and decision makers in assessing the potential effects of a specific contamination event and thus enable them to deduce the appropriate mitigation measures. One efficient strategy supporting this is using model based simulations. However, application in crisis situations requires ready-to-use and easy-to-adapt models to be available from the so-called food safety knowledge bases. Here, we illustrate this concept and its benefits by applying the modular open source software tools PMM-Lab and FoodProcess-Lab. As a fictitious sample scenario, an intentional ricin contamination at a beef salami production facility was modelled. Predictive models describing the inactivation of ricin were reviewed, relevant models were implemented with PMM-Lab, and simulations on residual toxin amounts in the final product were performed with FoodProcess-Lab. Due to the generic and modular modelling concept implemented in these tools, they can be applied to simulate virtually any food safety contamination scenario. Apart from the application in crisis situations, the food safety knowledge base concept will also be useful in food quality and safety investigations.

  17. Robust optical sensors for safety critical automotive applications

    NASA Astrophysics Data System (ADS)

    De Locht, Cliff; De Knibber, Sven; Maddalena, Sam

    2008-02-01

    Optical sensors for the automotive industry need to be robust, high performing and low cost. This paper focuses on the impact of automotive requirements on optical sensor design and packaging. Main strategies to lower optical sensor entry barriers in the automotive market include: Perform sensor calibration and tuning by the sensor manufacturer, sensor test modes on chip to guarantee functional integrity at operation, and package technology is key. As a conclusion, optical sensor applications are growing in automotive. Optical sensor robustness matured to the level of safety critical applications like Electrical Power Assisted Steering (EPAS) and Drive-by-Wire by optical linear arrays based systems and Automated Cruise Control (ACC), Lane Change Assist and Driver Classification/Smart Airbag Deployment by camera imagers based systems.

  18. Transit vehicle-to-infrastructure (V2I) applications : near term research and development. Transit bus-pedestrian/cyclist crossing safety application : operational concept.

    DOT National Transportation Integrated Search

    2013-11-01

    This document serves as an Operational Concept for the Transit Bus-Pedestrian/Cyclist Crossing Safety application. The purpose of this document is to provide an operational description of how the Transit Bus-Pedestrian/Cyclist Crossing Safety W...

  19. Safety Training for the Supervisor.

    ERIC Educational Resources Information Center

    Gardner, James E.

    Emphasizing causation and motivation, this guide to safety training for foremen and supervisors in industry provides a method for correcting an employee, whether after an accident or after detection of an unsafe act, through an interview designed to find the reasons behind the act. Supervisory responsibility for safety is indicated, together with…

  20. Fire safety applications for spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Olson, Sandra L.

    1989-01-01

    Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.

  1. Putting Safety in the Frame: Nurses' Sensemaking at Work.

    PubMed

    O'Keeffe, Valerie Jean; Thompson, Kirrilly Rebecca; Tuckey, Michelle Rae; Blewett, Verna Lesley

    2015-01-01

    Current patient safety policy focuses nursing on patient care goals, often overriding nurses' safety. Without understanding how nurses construct work health and safety (WHS), patient and nurse safety cannot be reconciled. Using ethnography, we examine social contexts of safety, studying 72 nurses across five Australian hospitals making decisions during patient encounters. In enacting safe practice, nurses used "frames" built from their contextual experiences to guide their behavior. Frames are produced by nurses, and they structure how nurses make sense of their work. Using thematic analysis, we identify four frames that inform nurses' decisions about WHS: (a) communicating builds knowledge, (b) experiencing situations guides decisions, (c) adapting procedures streamlines work, and (d) team working promotes safe working. Nurses' frames question current policy and practice by challenging how nurses' safety is positioned relative to patient safety. Recognizing these frames can assist the design and implementation of effective WHS management.

  2. 46 CFR 154.1435 - Medical first aid guide.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Medical first aid guide. 154.1435 Section 154.1435 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY... Equipment § 154.1435 Medical first aid guide. Each vessel must have a copy of the IMO Medical First Aid...

  3. Automated Mixed Traffic Vehicle (AMTV) technology and safety study

    NASA Technical Reports Server (NTRS)

    Johnston, A. R.; Peng, T. K. C.; Vivian, H. C.; Wang, P. K.

    1978-01-01

    Technology and safety related to the implementation of an Automated Mixed Traffic Vehicle (AMTV) system are discussed. System concepts and technology status were reviewed and areas where further development is needed are identified. Failure and hazard modes were also analyzed and methods for prevention were suggested. The results presented are intended as a guide for further efforts in AMTV system design and technology development for both near term and long term applications. The AMTV systems discussed include a low speed system, and a hybrid system consisting of low speed sections and high speed sections operating in a semi-guideway. The safety analysis identified hazards that may arise in a properly functioning AMTV system, as well as hardware failure modes. Safety related failure modes were emphasized. A risk assessment was performed in order to create a priority order and significant hazards and failure modes were summarized. Corrective measures were proposed for each hazard.

  4. Commercial-off-the-shelf (COTS) hardware and software for train control applications : system safety considerations.

    DOT National Transportation Integrated Search

    2003-04-01

    The objective of this study was to assess the feasibility of using commercial off-the-shelf(COTS)processor-based systems for safety- related railroad applications. From the safety perspective,the fundamental challenges of using COTS products are most...

  5. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  6. NHTSA data reference guide version 4. Volume 1, vehicle tests

    DOT National Transportation Integrated Search

    1997-04-01

    This guide documents the format of magnetic media (3.5 inch high density diskettes) to be submitted : to the National Highway Traffic Safety Administration (NHTSA) for vehicle crash tests. This guide is : designated Volume I. NHTSA Data Reference Gui...

  7. 75 FR 5167 - Office of Hazardous Materials Safety; Notice of Delays In Processing of Special Permits Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Delays In Processing of Special Permits Applications AGENCY: Pipeline..., Office of Hazardous Materials Special Permits and Approvals, Pipeline and Hazardous Materials Safety...

  8. 75 FR 78800 - Office of Hazardous Materials Safety; Notice of Delays in Processing of Special Permits Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-16

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Delays in Processing of Special Permits Applications AGENCY: Pipeline..., Office of Hazardous Materials Special Permits and Approvals, Pipeline and Hazardous Materials Safety...

  9. 76 FR 2726 - Withdrawal of Regulatory Guide 1.154

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-14

    ... NUCLEAR REGULATORY COMMISSION [NRC-2011-0010] Withdrawal of Regulatory Guide 1.154 AGENCY: Nuclear Regulatory Commission. ACTION: Withdrawal of Regulatory Guide 1.154, ``Format and Content of Plant-Specific Pressurized Thermal Shock Safety Analysis Reports for Pressurized Water Reactors.'' FOR FURTHER INFORMATION CONTACT: Mekonen M. Bayssie,...

  10. Microfabricated Chemical Sensors for Safety and Emission Control Applications

    NASA Technical Reports Server (NTRS)

    Hunter, G. W.; Neudeck, P. G.; Chen, L.-Y.; Knight, D.; Liu, C. C.; Wu, Q. H.

    1998-01-01

    Chemical sensor technology is being developed for leak detection, emission monitoring, and fire safety applications. The development of these sensors is based on progress in two types of technology: 1) Micromachining and microfabrication (MicroElectroMechanical Systems (MEMS)-based) technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Using these technologies, sensors to measure hydrogen, hydrocarbons, nitrogen oxides, carbon monoxide, oxygen, and carbon dioxide are being developed. A description is given of each sensor type and its present stage of development. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

  11. Commercial grade item (CGI) dedication of MDR relays for nuclear safety related applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, R.K.; Julka, A.; Modi, G.

    1994-08-01

    MDR relays manufactured by Potter and Brumfield (P and B) have been used in various safety related applications in commercial nuclear power plants. These include emergency safety features (ESF) actuation systems, emergency core cooling systems (ECCS) actuation, and reactor protection systems. The MDR relays manufactured prior to May 1990 showed signs of generic failure due to corrosion and outgassing of coil varnish. P and B has made design changes to correct these problems in relays manufactured after May 1990. However, P and B does not manufacture the relays under any 10CFR50 Appendix B quality assurance (QA) program. They manufacture themore » relays under their commercial QA program and supply these as commercial grade items. This necessitates CGI Dedication of these relays for use in nuclear-safety-related applications. This paper presents a CGI dedication program that has been used to dedicate the MDR relays manufactured after May 1990. The program is in compliance with current Nuclear Regulatory Commission (NRC) and Electric Power Research Institute (EPRI) guidelines and applicable industry standards; it specifies the critical characteristics of the relays, provides the tests and analysis required to verify the critical characteristics, the acceptance criteria for the test results, performs source verification to qualify P and B for its control of the critical characteristics, and provides documentation. The program provides reasonable assurance that the new MDR relays will perform their intended safety functions.« less

  12. Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

    PubMed

    Chen, Xiaojun; Xu, Lu; Wang, Wei; Li, Xing; Sun, Yi; Politis, Constantinus

    2016-09-01

    The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflow of the surgical template design and manufacturing is quite complicated before the final clinical application. The major goal of the paper is to provide a comprehensive reference source of the current and future development of the template design and manufacturing for relevant researchers. Expert commentary: This paper aims to present a review of the necessary procedures in the template-guided surgery including the image processing, 3D visualization, preoperative planning, surgical guide design and manufacturing. In addition, the template-guided clinical applications for various kinds of surgeries are reviewed, and it demonstrated that the precision of the surgery has been improved compared with the non-guided operations.

  13. Evaluating "The Safe Living Guide": A Home Hazard Checklist for Seniors

    ERIC Educational Resources Information Center

    Sorcinelli, Andrea; Shaw, Lynn; Freeman, Andrew; Cooper, Kim

    2007-01-01

    Purpose: The purpose of this study was to evaluate the utility and reliability of a home hazard checklist published in Health Canada, "The Safe Living Guide: A Guide to Home Safety for Seniors" (2003). Methods: 76 community-dwelling seniors evaluated the guide, and inter-rater reliability was determined through comparison of ratings of…

  14. Safety in Science. Curriculum Support Series.

    ERIC Educational Resources Information Center

    Lulashnyk, Lorne; Boonov, Janet

    Since the major causes of accidents are carelessness and a negative or apathetic attitude towards safety, this guide was developed to facilitate safe, stimulating science laboratory activities by providing both general and specific safety information presented in 12 sections. Subject areas considered in these sections include: 1)…

  15. 76 FR 38597 - Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration 49 CFR Parts 383 and 390 [Docket No. FMCSA-2011-0146] Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators of Certain Farm Vehicles and Off-Road Agricultural Equipment AGENCY: Federal Motor...

  16. 76 FR 50433 - Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-15

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration 49 CFR Parts 383 and 390 [Docket No. FMCSA-2011-0146] Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators of Certain Farm Vehicles and Off-Road Agricultural Equipment AGENCY: Federal Motor...

  17. A Guide to the Design of Occupational Safety and Health Training for Immigrant, Latino/a Dairy Workers.

    PubMed

    Menger, Lauren M; Rosecrance, John; Stallones, Lorann; Roman-Muniz, Ivette Noami

    2016-01-01

    Industrialized dairy production in the U.S. relies on an immigrant, primarily Latino/a, workforce to meet greater production demands. Given the high rates of injuries and illnesses on U.S. dairies, there is pressing need to develop culturally appropriate training to promote safe practices among immigrant, Latino/a dairy workers. To date, there have been few published research articles or guidelines specific to developing effective occupational safety and health (OSH) training for immigrant, Latino/a workers in the dairy industry. Literature relevant to safety training for immigrant workers in agriculture and other high-risk industries (e.g., construction) was examined to identify promising approaches. The aim of this paper is to provide a practical guide for researchers and practitioners involved in the design and implementation of effective OSH training programs for immigrant, Latino/a workers in the dairy industry. The search was restricted to peer-reviewed academic journals and guidelines published between 1980 and 2015 by universities or extension programs, written in English, and related to health and safety training among immigrant, Latino/a workers within agriculture and other high-risk industries. Relevant recommendations regarding effective training transfer were also included from literature in the field of industrial-organizational psychology. A total of 97 articles were identified, of which 65 met the inclusion criteria and made a unique and significant contribution. The review revealed a number of promising strategies for how to effectively tailor health and safety training for immigrant, Latino/a workers in the dairy industry grouped under five main themes: (1) understanding and involving workers; (2) training content and materials; (3) training methods; (4) maximizing worker engagement; and (5) program evaluation. The identification of best practices in the design and implementation of training programs for immigrant, Latino/a workers within

  18. A Guide to the Design of Occupational Safety and Health Training for Immigrant, Latino/a Dairy Workers

    PubMed Central

    Menger, Lauren M.; Rosecrance, John; Stallones, Lorann; Roman-Muniz, Ivette Noami

    2016-01-01

    Industrialized dairy production in the U.S. relies on an immigrant, primarily Latino/a, workforce to meet greater production demands. Given the high rates of injuries and illnesses on U.S. dairies, there is pressing need to develop culturally appropriate training to promote safe practices among immigrant, Latino/a dairy workers. To date, there have been few published research articles or guidelines specific to developing effective occupational safety and health (OSH) training for immigrant, Latino/a workers in the dairy industry. Literature relevant to safety training for immigrant workers in agriculture and other high-risk industries (e.g., construction) was examined to identify promising approaches. The aim of this paper is to provide a practical guide for researchers and practitioners involved in the design and implementation of effective OSH training programs for immigrant, Latino/a workers in the dairy industry. The search was restricted to peer-reviewed academic journals and guidelines published between 1980 and 2015 by universities or extension programs, written in English, and related to health and safety training among immigrant, Latino/a workers within agriculture and other high-risk industries. Relevant recommendations regarding effective training transfer were also included from literature in the field of industrial–organizational psychology. A total of 97 articles were identified, of which 65 met the inclusion criteria and made a unique and significant contribution. The review revealed a number of promising strategies for how to effectively tailor health and safety training for immigrant, Latino/a workers in the dairy industry grouped under five main themes: (1) understanding and involving workers; (2) training content and materials; (3) training methods; (4) maximizing worker engagement; and (5) program evaluation. The identification of best practices in the design and implementation of training programs for immigrant, Latino/a workers within

  19. Potential applications of video technology for traffic management and safety in Alabama

    DOT National Transportation Integrated Search

    2002-11-25

    Video technology applications for traffic management and safety are being implemented by state and local government agencies in Alabama. This technology offers both tangible and intangible benefits. Although video technology provides many benefits, i...

  20. Towards a Food Safety Knowledge Base Applicable in Crisis Situations and Beyond

    PubMed Central

    Falenski, Alexander; Weiser, Armin A.; Thöns, Christian; Appel, Bernd; Käsbohrer, Annemarie; Filter, Matthias

    2015-01-01

    In case of contamination in the food chain, fast action is required in order to reduce the numbers of affected people. In such situations, being able to predict the fate of agents in foods would help risk assessors and decision makers in assessing the potential effects of a specific contamination event and thus enable them to deduce the appropriate mitigation measures. One efficient strategy supporting this is using model based simulations. However, application in crisis situations requires ready-to-use and easy-to-adapt models to be available from the so-called food safety knowledge bases. Here, we illustrate this concept and its benefits by applying the modular open source software tools PMM-Lab and FoodProcess-Lab. As a fictitious sample scenario, an intentional ricin contamination at a beef salami production facility was modelled. Predictive models describing the inactivation of ricin were reviewed, relevant models were implemented with PMM-Lab, and simulations on residual toxin amounts in the final product were performed with FoodProcess-Lab. Due to the generic and modular modelling concept implemented in these tools, they can be applied to simulate virtually any food safety contamination scenario. Apart from the application in crisis situations, the food safety knowledge base concept will also be useful in food quality and safety investigations. PMID:26247028

  1. Roundabouts: An informational Guide (Brochure)

    DOT National Transportation Integrated Search

    2012-09-01

    This assessment evaluates the applicability of the current light vehicle safety applications for use on transit vehicles in revenue service operation. This assessment includes the following elements: A review of light vehicle safety applications ...

  2. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases.

    PubMed

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-12-14

    To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients ( P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group ( P < 0.05). Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration.

  3. CT fluoroscopy-guided renal tumour cutting needle biopsy: retrospective evaluation of diagnostic yield, safety, and risk factors for diagnostic failure.

    PubMed

    Iguchi, Toshihiro; Hiraki, Takao; Matsui, Yusuke; Fujiwara, Hiroyasu; Sakurai, Jun; Masaoka, Yoshihisa; Gobara, Hideo; Kanazawa, Susumu

    2018-01-01

    To evaluate retrospectively the diagnostic yield, safety, and risk factors for diagnostic failure of computed tomography (CT) fluoroscopy-guided renal tumour biopsy. Biopsies were performed for 208 tumours (mean diameter 2.3 cm; median diameter 2.1 cm; range 0.9-8.5 cm) in 199 patients. One hundred and ninety-nine tumours were ≤4 cm. All 208 initial procedures were divided into diagnostic success and failure groups. Multiple variables related to the patients, lesions, and procedures were assessed to determine the risk factors for diagnostic failure. After performing 208 initial and nine repeat biopsies, 180 malignancies and 15 benign tumours were pathologically diagnosed, whereas 13 were not diagnosed. In 117 procedures, 118 Grade I and one Grade IIIa adverse events (AEs) occurred. Neither Grade ≥IIIb AEs nor tumour seeding were observed within a median follow-up period of 13.7 months. Logistic regression analysis revealed only small tumour size (≤1.5 cm; odds ratio 3.750; 95% confidence interval 1.362-10.326; P = 0.011) to be a significant risk factor for diagnostic failure. CT fluoroscopy-guided renal tumour biopsy is a safe procedure with a high diagnostic yield. A small tumour size (≤1.5 cm) is a significant risk factor for diagnostic failure. • CT fluoroscopy-guided renal tumour biopsy has a high diagnostic yield. • CT fluoroscopy-guided renal tumour biopsy is safe. • Small tumour size (≤1.5 cm) is a risk factor for diagnostic failure.

  4. Extended use of the GuideLiner in complex coronary interventions.

    PubMed

    Chan, Pak Hei; Alegria-Barrero, Eduardo; Foin, Nicholas; Paulo, Manuel; Lindsay, Alistair C; Viceconte, Nicola; Di Mario, Carlo

    2015-07-01

    Challenging coronary anatomies including chronic total occlusions (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries pose difficulties in coronary interventions. The GuideLiner is a monorail catheter originally developed to facilitate delivery of stents to target lesions in tortuous vessels. We conducted a study on the feasibility and safety of utilising this catheter in a wider array of complex coronary interventions. Consecutive patients undergoing coronary or peripheral interventions where a GuideLiner was used were recruited into this study. Patient demographics, lesion and vessel characteristics, procedural details and outcomes were prospectively entered into our database and analysed. From September 2009 to October 2011, 54 consecutive patients underwent coronary intervention in our institution using a GuideLiner; 21 out of 54 coronary applications were motivated by the need to increase support to cross CTOs, predominantly of the RCA. Anomalous or angulated take-off of the treatment vessels (31%), previously deployed proximal stents (15%), heavy proximal calcification (9%) and tortuosity (7%) accounted for the remaining reasons. One patient had successful renal denervation with the aid of a GuideLiner catheter. Procedural success was 98% in our series with no device-related periprocedural complications such as ostial dissection or myocardial necrosis. The use of a GuideLiner facilitates the approach to complex coronary interventions including chronic total occlusion and saphenous vein graft intervention by providing greater back-up support and easier engagement of coronary ostia.

  5. Vocational Electronics Second Year Teacher's Guide and Student Workbook.

    ERIC Educational Resources Information Center

    Solanik, Chuck

    This guide is intended to help teachers give preparatory instruction in the development of basic manipulative skills, safety practices, technical knowledge, and related industrial information in order to prepare students for useful employment in the field of electronics. This second-year guide contains 7 units organized into 21 lesson plans. Each…

  6. Vocational Electronics First Year Teacher's Guide and Student Workbook.

    ERIC Educational Resources Information Center

    Solanik, Chuck

    This guide is intended to help teachers give preparatory instruction in the development of basic manipulative skills, safety practices, technical knowledge, and related industrial information in order to prepare students for useful employment in the field of electronics. This first-year guide contains 6 units organized in 21 lesson plans. Each…

  7. Citizen's Guide to Pesticides.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Pesticide Programs.

    This guide provides suggestions on pest control and safety rules for pesticide use at home. Pest prevention may be possible by modification of pest habitat: removal of food and water sources, removal or destruction of pest shelter and breeding sites, and good horticultural practices that reduce plant stress. Nonchemical alternatives to pesticides…

  8. Application of composite materials to turbofan engine fan exit guide vanes

    NASA Technical Reports Server (NTRS)

    Smith, G. T.

    1980-01-01

    A program was conducted by NASA with the JT9D engine manufacturer to develop a lightweight, cost effective, composite material fan exit guide vane design having satisfactory structural durability for commerical engine use. Based on the results of a previous company supported program, eight graphite/epoxy and graphite-glass/epoxy guide vane designs were evaluated and four were selected for fabrication and testing. Two commercial fabricators each fabricated 13 vanes. Fatigue tests were used to qualify the selected design configurations under nominally dry, 38 C (100 F) and fully wet and 60 C (140 F) environmental conditions. Cost estimates for a production rate of 1000 vanes per month ranged from 1.7 to 2.6 times the cost of an all aluminum vane. This cost is 50 to 80 percent less than the initial program target cost ratio which was 3 times the cost of an aluminum vane. Application to the JT9D commercial engine is projected to provide a weight savings of 236 N (53 lb) per engine.

  9. Safety Assurance Factors for Electronic Health Record Resilience (SAFER): study protocol

    PubMed Central

    2013-01-01

    Background Implementation and use of electronic health records (EHRs) could lead to potential improvements in quality of care. However, the use of EHRs also introduces unique and often unexpected patient safety risks. Proactive assessment of risks and vulnerabilities can help address potential EHR-related safety hazards before harm occurs; however, current risk assessment methods are underdeveloped. The overall objective of this project is to develop and validate proactive assessment tools to ensure that EHR-enabled clinical work systems are safe and effective. Methods/Design This work is conceptually grounded in an 8-dimension model of safe and effective health information technology use. Our first aim is to develop self-assessment guides that can be used by health care institutions to evaluate certain high-risk components of their EHR-enabled clinical work systems. We will solicit input from subject matter experts and relevant stakeholders to develop guides focused on 9 specific risk areas and will subsequently pilot test the guides with individuals representative of likely users. The second aim will be to examine the utility of the self-assessment guides by beta testing the guides at selected facilities and conducting on-site evaluations. Our multidisciplinary team will use a variety of methods to assess the content validity and perceived usefulness of the guides, including interviews, naturalistic observations, and document analysis. The anticipated output of this work will be a series of self-administered EHR safety assessment guides with clear, actionable, checklist-type items. Discussion Proactive assessment of patient safety risks increases the resiliency of health care organizations to unanticipated hazards of EHR use. The resulting products and lessons learned from the development of the assessment guides are expected to be helpful to organizations that are beginning the EHR selection and implementation process as well as those that have already

  10. Theoretical Analysis of the Accuracy and Safety of MRI-Guided Transurethral 3-D Conformal Ultrasound Prostate Therapy

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound therapy is a promising new approach for the treatment of localized prostate cancer. Several studies have demonstrated the feasibility of producing large regions of thermal coagulation adequate for prostate therapy; however, the quantitative assessment of shaping these regions to complex 3-D human prostate geometries has not been fully explored. This study used numerical simulations and twenty manually-segmented pelvic anatomical models derived from high-quality MR images of prostate cancer patients to evaluate the treatment accuracy and safety of 3-D conformal MRI-guided transurethral ultrasound therapy. The simulations incorporated a rotating multi-element planar dual-frequency ultrasound transducer (seventeen 4×3 mm elements) operating at 4.7/9.7 MHz and 10 W/cm2 maximum acoustic power. Results using a novel feedback control algorithm which modulated the ultrasound frequency, power and device rate of rotation showed that regions of thermal coagulation could be shaped to predefined prostate volumes within 1.0 mm across the vast majority of these glands. Treatment times were typically 30 min and remained below 60 min for large 60 cc prostates. With a rectal cooling temperature of 15° C, the rectal wall did not exceed 30EM43 in half of the twenty patient models with only a few 1 mm3 voxels above this threshold in the other cases. At 4.7 MHz, heating of the pelvic bone can become significant when it is located less than 10 mm from the prostate. Numerical simulations show that MRI-guided transurethral ultrasound therapy can thermally coagulate whole prostate glands accurately and safely in 3-D.

  11. Application of Survival Analysis and Multistate Modeling to Understand Animal Behavior: Examples from Guide Dogs

    PubMed Central

    Asher, Lucy; Harvey, Naomi D.; Green, Martin; England, Gary C. W.

    2017-01-01

    Epidemiology is the study of patterns of health-related states or events in populations. Statistical models developed for epidemiology could be usefully applied to behavioral states or events. The aim of this study is to present the application of epidemiological statistics to understand animal behavior where discrete outcomes are of interest, using data from guide dogs to illustrate. Specifically, survival analysis and multistate modeling are applied to data on guide dogs comparing dogs that completed training and qualified as a guide dog, to those that were withdrawn from the training program. Survival analysis allows the time to (or between) a binary event(s) and the probability of the event occurring at or beyond a specified time point. Survival analysis, using a Cox proportional hazards model, was used to examine the time taken to withdraw a dog from training. Sex, breed, and other factors affected time to withdrawal. Bitches were withdrawn faster than dogs, Labradors were withdrawn faster, and Labrador × Golden Retrievers slower, than Golden Retriever × Labradors; and dogs not bred by Guide Dogs were withdrawn faster than those bred by Guide Dogs. Multistate modeling (MSM) can be used as an extension of survival analysis to incorporate more than two discrete events or states. Multistate models were used to investigate transitions between states of training to qualification as a guide dog or behavioral withdrawal, and from qualification as a guide dog to behavioral withdrawal. Sex, breed (with purebred Labradors and Golden retrievers differing from F1 crosses), and bred by Guide Dogs or not, effected movements between states. We postulate that survival analysis and MSM could be applied to a wide range of behavioral data and key examples are provided. PMID:28804710

  12. Surveying wearable human assistive technology for life and safety critical applications: standards, challenges and opportunities.

    PubMed

    Alam, Muhammad Mahtab; Ben Hamida, Elyes

    2014-05-23

    In this survey a new application paradigm life and safety for critical operations and missions using wearable Wireless Body Area Networks (WBANs) technology is introduced. This paradigm has a vast scope of applications, including disaster management, worker safety in harsh environments such as roadside and building workers, mobile health monitoring, ambient assisted living and many more. It is often the case that during the critical operations and the target conditions, the existing infrastructure is either absent, damaged or overcrowded. In this context, it is envisioned that WBANs will enable the quick deployment of ad-hoc/on-the-fly communication networks to help save many lives and ensuring people's safety. However, to understand the applications more deeply and their specific characteristics and requirements, this survey presents a comprehensive study on the applications scenarios, their context and specific requirements. It explores details of the key enabling standards, existing state-of-the-art research studies, and projects to understand their limitations before realizing aforementioned applications. Application-specific challenges and issues are discussed comprehensively from various perspectives and future research and development directions are highlighted as an inspiration for new innovative solutions. To conclude, this survey opens up a good opportunity for companies and research centers to investigate old but still new problems, in the realm of wearable technologies, which are increasingly evolving and getting more and more attention recently.

  13. Surveying Wearable Human Assistive Technology for Life and Safety Critical Applications: Standards, Challenges and Opportunities

    PubMed Central

    Alam, Muhammad Mahtab; Ben Hamida, Elyes

    2014-01-01

    In this survey a new application paradigm life and safety for critical operations and missions using wearable Wireless Body Area Networks (WBANs) technology is introduced. This paradigm has a vast scope of applications, including disaster management, worker safety in harsh environments such as roadside and building workers, mobile health monitoring, ambient assisted living and many more. It is often the case that during the critical operations and the target conditions, the existing infrastructure is either absent, damaged or overcrowded. In this context, it is envisioned that WBANs will enable the quick deployment of ad-hoc/on-the-fly communication networks to help save many lives and ensuring people's safety. However, to understand the applications more deeply and their specific characteristics and requirements, this survey presents a comprehensive study on the applications scenarios, their context and specific requirements. It explores details of the key enabling standards, existing state-of-the-art research studies, and projects to understand their limitations before realizing aforementioned applications. Application-specific challenges and issues are discussed comprehensively from various perspectives and future research and development directions are highlighted as an inspiration for new innovative solutions. To conclude, this survey opens up a good opportunity for companies and research centers to investigate old but still new problems, in the realm of wearable technologies, which are increasingly evolving and getting more and more attention recently. PMID:24859024

  14. 9 CFR 390.3 - Indexes, reference guide, and handbook.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Indexes, reference guide, and handbook. 390.3 Section 390.3 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE ADMINISTRATIVE PROVISIONS FREEDOM OF INFORMATION AND PUBLIC...

  15. A nurse-guided, basal-prandial insulin treatment protocol for achieving glycaemic control of hospitalized, non-critically ill diabetes patients, is non-inferior to physician-guided therapy: A pivotal, nurse-empowerment study.

    PubMed

    Segal, Gad; Karniel, Eli; Mahagna, Ahmed; Kaa'dan, Fadi; Levi, Zehava; Balik, Chaya

    2015-12-01

    Basal-prandial insulin is established for glycaemic control for hospitalized, type 2 diabetes patients. Empowering nurses to guide such protocols could be advantageous.The study aims to comparatively assess the efficacy and safety of glycaemic control by a nurse-guided protocol with physician-guided therapy. It also aims to assess the impact of empowerment on the nurses' sense of competence. This is a prospective, controlled, randomized, single-blinded study. Validated protocol utilizing basal-prandial insulin was used. Glycaemic control was the primary efficacy outcome, whereas hypoglycaemia and laboratory parameters were followed for safety. Assessment of nurses' psychological empowerment was done. One hundred fifty-eight treatment days of 53 patients were included. Patients were randomized to either study group (n = 27) or control group (n = 26). Glycaemia deviation from liberal range (60-300 mg/dL) was 7.4% of days for nurse-guided, basal-prandial insulin treatment protocol (NGP) and 7.84% for physician-guided therapy (PGT), P = 0.901. Rate of glycaemia deviation from the strict range (100-180 mg/dL) was 49.76% for NGP and 47.38% for PGT, P = 0.703. Mean range of daily deviation was similar (77.05 mg/dL for NGP and 76.04 mg/dL for PGT, P = 0.93). There were no significant differences in safety parameters. An empowerment questionnaire showed tendency for increased nurses' sense of competence. Nurse-guided protocol is non-inferior to physician-guided treatment in efficacy and safety parameters. Nurses' sense of competence was positively influenced. © 2014 Wiley Publishing Asia Pty Ltd.

  16. Economic and Societal Factors Instructional Guide. Student Materials.

    ERIC Educational Resources Information Center

    Hendrix, Mary W.

    These student materials are designed to accompany the Economic and Societal Factors Instructional Guide. Page numbers are consistent with the numbering in that guide. The guide's nine units deal with the following topics: (1) job acquisition (sources of employment, job application, completing the application form, resume, job interview, follow-up…

  17. 76 FR 5494 - Pipeline Safety: Mechanical Fitting Failure Reporting Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-01

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration 49 CFR Part... Safety: Mechanical Fitting Failure Reporting Requirements AGENCY: Pipeline and Hazardous Materials Safety... tightening. A widely accepted industry guidance document, Gas Pipeline Technical Committee (GPTC) Guide, does...

  18. Nuclear safety

    NASA Technical Reports Server (NTRS)

    Buden, D.

    1991-01-01

    Topics dealing with nuclear safety are addressed which include the following: general safety requirements; safety design requirements; terrestrial safety; SP-100 Flight System key safety requirements; potential mission accidents and hazards; key safety features; ground operations; launch operations; flight operations; disposal; safety concerns; licensing; the nuclear engine for rocket vehicle application (NERVA) design philosophy; the NERVA flight safety program; and the NERVA safety plan.

  19. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  20. MO-DE-202-02: Advances in Image Registration and Reconstruction for Image-Guided Neurosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siewerdsen, J.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41

  1. Safety of High Speed Guided Ground Transportation Systems : Comparison of Magnetic and Electric Fields of Conventional and Advanced Electrified Transportation Systems

    DOT National Transportation Integrated Search

    1993-08-01

    The safety of magnetically levitated (maglev) and high speed rail (HSR) passenger trains proposed for application in the United States is the responsibility of the Federal Railroad Administration (FRA). Plans for near future US applications include m...

  2. Safety of High Speed Guided Ground Transportation Systems : Magnetic and Electric Field Testing of the Massachusetts Bay Transportation ... v. 2. Appendix

    DOT National Transportation Integrated Search

    1993-06-01

    The safety of magnetically levitated (maglev) and high speed rail (HSR) trains proposed for application in the United States is the responsibility of the Federal Railroad Administration (FRA). Plans for near future US applications include maglev proj...

  3. NHTSA data reference guide version 4.b. Volume 2, biomechanical tests

    DOT National Transportation Integrated Search

    1999-05-01

    This guide documents the format of media (3.5 inch high density diskettes or CD-ROMs) to : be submitted to the National Highway Traffic Safety Administration (NHTSA) for : biomechanical tests. This guide is designated Volume II. NHTSA Data Reference ...

  4. Applications and safety considerations of Lactobacillus salivarius as a probiotic in animal and human health.

    PubMed

    Chaves, B D; Brashears, M M; Nightingale, K K

    2017-03-03

    The goals of this review are to summarize the current knowledge on the application of Lactobacillus salivarius as a probiotic in animals and humans, and to address safety concerns with its use on live hosts. Overall, several strains of L. salivarius are well established probiotics with multiple applications in animal health, particularly to reduce colonization by gastrointestinal pathogens, and to a lesser extent, as a production and quality aid. In humans, L. salivarius has been used to prevent and treat a variety of chronic diseases, including asthma, cancer, atopic dermatitis and halitosis, and to a much limited extent, to prevent or treat infections. Based on the results from primary research evidence, it seems that L. salivarius does not pose a health risk to animals or humans in the doses currently used for a variety of applications; however, there is a systematic lack of studies assuring the safety of many of the strains intended for clinical use. This review provides researchers in the field with up-to-date information regarding applications and safety of L. salivarius. Furthermore, it helps researchers identify knowledge gaps and potential opportunities for microbiological and clinical research. © 2017 The Society for Applied Microbiology.

  5. Parachute Rigger Knowledge Test Guide

    DOT National Transportation Integrated Search

    1995-01-01

    The Flight Standards Service of the Federal Aviation Administration (FAA) has developed this guide to help : applicants meet the knowledge requirements for parachute rigger certification. : This guide contains information about eligibility requiremen...

  6. Safety and efficacy of antioxidants-loaded nanoparticles for an anti-aging application.

    PubMed

    Felippi, Cândice C; Oliveira, Dileusa; Ströher, Alessandra; Carvalho, Anderson R; Van Etten, Eliana A M Aquino; Bruschi, Márcia; Raffin, Renata P

    2012-04-01

    The aim of this work was to perform a pilot study on the safety and efficacy of nanoparticle formulation for cosmetic application. The encapsulated actives in the nanoparticles were a blend of coenzyme Q10, retinyl palmitate, tocopheryl acetate, grape seed oil and linseed oil. The nanoparticle suspension was characterized in terms of pH and particle size. For the safety assessment, alternative methods as cytotoxicity and HET CAM were used. The clinical skin compatibility tests were also performed. The efficacy was evaluated in healthy volunteers presenting different degrees of periorbital wrinkles. Skin hydration was performed by corneometry. The nanoparticles presented narrow size around 140 nm and pH close to neutral and were suitable to cutaneous application. The alternative tests demonstrated that the nanoparticles did not present potential to induce skin irritant effects, cytotoxicity or generate oxidative stress. The clinical assays confirmed the in vitro results, demonstrating the safety of the nanoparticles, which were not irritant, sensitizing and comedogenic. Furthermore, the exposure to UVA light did not cause photoxicity. Regarding the efficacy, nanoparticles presented significant reduction in wrinkle degree after 21 days of application compared to the control. The volunteers could differentiate the nanoparticles and the control product by means of subjective analyses. In conclusion, the nanoparticles containing antioxidant actives were safe for topical use and presented anti-aging activity in vivo and are suitable to be used as cosmetic ingredient.

  7. Occupational Safety and Health Programs in Career Education.

    ERIC Educational Resources Information Center

    DiCarlo, Robert D.; And Others

    This resource guide was developed in response to the Occupational Safety and Health Act of 1970 and is intended to assist teachers in implementing courses in occupational safety and health as part of a career education program. The material is a synthesis of films, programed instruction, slides and narration, case studies, safety pamphlets,…

  8. Safety of High-Speed Guided Ground Transportation Systems : Shared Right-of-Way Safety Issues

    DOT National Transportation Integrated Search

    1992-09-01

    One of the most important issues in the debate over the viability in the United States of high-speed guided ground : transportation (HSGGT) systems, which include magnetic levitation (maglev) and high-speed rail (HSR), is the : feasibility of using e...

  9. 49 CFR Appendix C to Part 222 - Guide to Establishing Quiet Zones

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Guide to Establishing Quiet Zones C Appendix C to.... 222, App. C Appendix C to Part 222—Guide to Establishing Quiet Zones Introduction This Guide to... without implementation of additional safety measures at any crossings in the quiet zone; or c. Additional...

  10. 7 CFR 3430.31 - Guiding principles.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Guiding principles. 3430.31 Section 3430.31 Agriculture Regulations of the Department of Agriculture (Continued) COOPERATIVE STATE RESEARCH, EDUCATION... § 3430.31 Guiding principles. The guiding principle for Federal assistance application review and...

  11. Safety in the Elementary Science Classroom.

    ERIC Educational Resources Information Center

    National Science Teachers Association, Arlington, VA.

    This guide gives elementary school teachers suggestions for providing a safe environment for their students and covers general safety concerns in the science classroom. Information is printed in a flip chart format for easy reference. Safety areas covered include: (1) In Case of Accident; (2) Eye Protection; (3) Plants in the Classroom; (4) First…

  12. Safety in the Elementary Science Classroom.

    ERIC Educational Resources Information Center

    Dean, Robert A.; And Others

    This safety guide for elementary school science teachers who plan science activities or laboratories for their students, presents information in the form of a flip chart that can be posted in the classroom and referred to in an emergency. Space is provided for emergency telephone numbers. A safety checklist is given for the teacher. Topics…

  13. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases

    PubMed Central

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-01-01

    AIM To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. METHODS Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. RESULTS There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients (P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group (P < 0.05). CONCLUSION Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration. PMID:28028373

  14. Improving safety on rural local and tribal roads.

    DOT National Transportation Integrated Search

    2014-08-01

    Rural roadway safety is an important issue for communities throughout the country and presents a challenge for local and Tribal agencies. The FHWA created a Toolkit and two User Guides to help rural local and Tribal roadway safety practitioners addre...

  15. Teaching Guide for the Traffic Signal Light Program: Kindergarten Level.

    ERIC Educational Resources Information Center

    Maryland State Dept. of Education, Baltimore.

    This teachers' guide provides materials and suggestions for approximately 125 lessons that are designed to increase kindergarten children's traffic safety skills and knowledge. Most of the guide focuses on (1) lessons about physical structures in the pedestrian environment such as sidewalks, curbs, crosswalks, and intersections, and (2) signal…

  16. Fluorescence-Guided Surgery

    PubMed Central

    Nagaya, Tadanobu; Nakamura, Yu A.; Choyke, Peter L.; Kobayashi, Hisataka

    2017-01-01

    Surgical resection of cancer remains an important treatment modality. Despite advances in preoperative imaging, surgery itself is primarily guided by the surgeon’s ability to locate pathology with conventional white light imaging. Fluorescence-guided surgery (FGS) can be used to define tumor location and margins during the procedure. Intraoperative visualization of tumors may not only allow more complete resections but also improve safety by avoiding unnecessary damage to normal tissue which can also reduce operative time and decrease the need for second-look surgeries. A number of new FGS imaging probes have recently been developed, complementing a small but useful number of existing probes. In this review, we describe current and new fluorescent probes that may assist FGS. PMID:29312886

  17. Robotic System for MRI-Guided Stereotactic Neurosurgery

    PubMed Central

    Li, Gang; Cole, Gregory A.; Shang, Weijian; Harrington, Kevin; Camilo, Alex; Pilitsis, Julie G.; Fischer, Gregory S.

    2015-01-01

    Stereotaxy is a neurosurgical technique that can take several hours to reach a specific target, typically utilizing a mechanical frame and guided by preoperative imaging. An error in any one of the numerous steps or deviations of the target anatomy from the preoperative plan such as brain shift (up to 20 mm), may affect the targeting accuracy and thus the treatment effectiveness. Moreover, because the procedure is typically performed through a small burr hole opening in the skull that prevents tissue visualization, the intervention is basically “blind” for the operator with limited means of intraoperative confirmation that may result in reduced accuracy and safety. The presented system is intended to address the clinical needs for enhanced efficiency, accuracy, and safety of image-guided stereotactic neurosurgery for Deep Brain Stimulation (DBS) lead placement. The work describes a magnetic resonance imaging (MRI)-guided, robotically actuated stereotactic neural intervention system for deep brain stimulation procedure, which offers the potential of reducing procedure duration while improving targeting accuracy and enhancing safety. This is achieved through simultaneous robotic manipulation of the instrument and interactively updated in situ MRI guidance that enables visualization of the anatomy and interventional instrument. During simultaneous actuation and imaging, the system has demonstrated less than 15% signal-to-noise ratio (SNR) variation and less than 0.20% geometric distortion artifact without affecting the imaging usability to visualize and guide the procedure. Optical tracking and MRI phantom experiments streamline the clinical workflow of the prototype system, corroborating targeting accuracy with 3-axis root mean square error 1.38 ± 0.45 mm in tip position and 2.03 ± 0.58° in insertion angle. PMID:25376035

  18. 76 FR 65544 - Standard Format and Content of License Applications for Mixed Oxide Fuel Fabrication Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-21

    ...The U.S. Nuclear Regulatory Commission (NRC or Commission) is issuing a revision to regulatory guide (RG) 3.39, ``Standard Format and Content of License Applications for Mixed Oxide Fuel Fabrication Facilities.'' This guide endorses the standard format and content for license applications and integrated safety analysis (ISA) summaries described in the current version of NUREG-1718, ``Standard Review Plan for the Review of an Application for a Mixed Oxide (MOX) Fuel Fabrication Facility,'' as a method that the NRC staff finds acceptable for meeting the regulatory requirements of Title 10 of the Code of Federal Regulations (10 CFR) part 70, ``Domestic Licensing of Special Nuclear Material'' for mixed oxide fuel fabrication facilities.

  19. Carpentry and Finishing Procedures. Building Maintenance. Module II. Instructor's Guide.

    ERIC Educational Resources Information Center

    Hawk, Sam; Brunk, Art

    This curriculum guide, keyed to the building maintenance competency profile developed by industry and education professionals, provides three units on carpentry and finishing procedures. The first unit, Exterior Carpentry, contains the following lessons: carpentry safety procedures, ladder and scaffolding safety, door installation/repair,…

  20. Stereo electroencephalography-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) in drug-resistant focal epilepsy: Results from a 10-year experience.

    PubMed

    Bourdillon, Pierre; Isnard, Jean; Catenoix, Hélène; Montavont, Alexandra; Rheims, Sylvain; Ryvlin, Philippe; Ostrowsky-Coste, Karine; Mauguiere, François; Guénot, Marc

    2017-01-01

    Stereo electroencephalography (SEEG)-guided radiofrequency thermocoagulation (SEEG-guided RF-TC) has been proposed since 2004 as a possible treatment of some focal drug-resistant epilepsy. The aim of this study is to provide extensive data about efficacy and safety of SEEG-guided RF-TC. Over a 10-year period, 162 patients with drug-resistant focal epilepsy were eligible for SEEG-guided RF-TG during phase II invasive investigation by SEEG. All follow-up and safety data were collected prospectively. The primary outcome was seizure freedom at 2 months and at 1 year after SEEG-guided RF-TC. Secondary outcomes were the responders' rate (patient with at least 50% decrease in seizure frequency) and their long-term follow-up. Twenty-five percent of patients were seizure-free at 2 months and 7% at 1 year. We reported 67% of responders at 2 months and 48% at 1 year; 58% of responders maintained their status during the long-term follow-up. The seizure outcome was significantly better when the SEEG-guided RF-TC involved the occipital region (p = 0.007). When surgery followed an SEEG-guided RF-TC, the positive predictive value of being a responder 2 months after an SEEG-guided RF-TC and to be Engel's class I or II after surgery was 93%. We reported 1.1% of permanent deficit and 2.4% of transient side effects. Our results, gathered in a large population over a 10-year period, confirm that SEEG-guided RF-TC is a safe technique, being efficient in many cases. More than two thirds of patients showed a short-term improvement, and almost half of them were responders at 1-year follow-up. The technique appears to be especially interesting for limited epileptic zone inaccessible to surgery and when epilepsy is related to a large unilateral network (network disruption by multiple RF-TC). Furthermore, SEEG-guided RF-TC effect is a predictor of outcome after conventional cortectomy in patients eligible for surgery. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  1. Application of visualization and simulation program to improve work zone safety and mobility.

    DOT National Transportation Integrated Search

    2010-01-01

    A previous study sponsored by the Smart Work Zone Deployment Initiative, Feasibility of Visualization and Simulation Applications to Improve Work Zone Safety and Mobility, demonstrated the feasibility of combining readily available, inexpensive...

  2. Application of visualization and simulation program to improve work zone safety and mobility.

    DOT National Transportation Integrated Search

    2010-01-01

    "A previous study sponsored by the Smart Work Zone Deployment Initiative, Feasibility of Visualization and Simulation Applications to Improve Work Zone Safety and Mobility, demonstrated the feasibility of combining readily available, inexpensiv...

  3. WE-EF-BRD-01: Past, Present and Future: MRI-Guided Radiotherapy From 2005 to 2025

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lagendijk, J.

    MRI-guided treatment is a growing area of medicine, particularly in radiotherapy and surgery. The exquisite soft tissue anatomic contrast offered by MRI, along with functional imaging, makes the use of MRI during therapeutic procedures very attractive. Challenging the utility of MRI in the therapy room are many issues including the physics of MRI and the impact on the environment and therapeutic instruments, the impact of the room and instruments on the MRI; safety, space, design and cost. In this session, the applications and challenges of MRI-guided treatment will be described. The session format is: Past, present and future: MRI-guided radiotherapymore » from 2005 to 2025: Jan Lagendijk Battling Maxwell’s equations: Physics challenges and solutions for hybrid MRI systems: Paul Keall I want it now!: Advances in MRI acquisition, reconstruction and the use of priors to enable fast anatomic and physiologic imaging to inform guidance and adaptation decisions: Yanle Hu MR in the OR: The growth and applications of MRI for interventional radiology and surgery: Rebecca Fahrig Learning Objectives: To understand the history and trajectory of MRI-guided radiotherapy To understand the challenges of integrating MR imaging systems with linear accelerators To understand the latest in fast MRI methods to enable the visualisation of anatomy and physiology on radiotherapy treatment timescales To understand the growing role and challenges of MRI for image-guided surgical procedures My disclosures are publicly available and updated at: http://sydney.edu.au/medicine/radiation-physics/about-us/disclosures.php.« less

  4. MO-DE-202-04: Multimodality Image-Guided Surgery and Intervention: For the Rest of Us

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shekhar, R.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41

  5. Small-bore wire-guided chest drains: safety, tolerability, and effectiveness in pneumothorax, malignant effusions, and pleural empyema.

    PubMed

    Cafarotti, Stefano; Dall'Armi, Valentina; Cusumano, Giacomo; Margaritora, Stefano; Meacci, Elisa; Lococo, F; Vita, M L; Porziella, V; Bonassi, S; Cesario, Alfredo; Granone, Pierluigi

    2011-03-01

    The use of small-bore wire-guided chest drains for pleural effusions and pneumothorax has become popular; however, limited data are available on its efficacy and morbidity. The aim of this retrospective study is to measure, via the analysis of the so far largest reported cohort, the efficacy, safety, and tolerability of this approach in different clinical conditions. In the period from January 2002 to December 2008, 1092 patients have undergone the positioning of a small-bore wire-guided chest drain (12F) for the evidence of pneumothorax or pleural effusion and have been monitored over time for morbidity, pain at the time of insertion (measured via the visual analogue scale), and drain failure for misplacement or blockage. Patients with trauma were excluded from this study. Male/female ratio and mean age were respectively 418:674 and 55.85 ± 18.6. Three-hundred ninety-nine (36.5%) drains were inserted for pneumothorax, 324 (29.7%) for malignant effusion, 97 (8.9%) for empyema, and 272 (24.9%) for nonmalignant effusion. The pain experience was on average "very mild" (mean visual analogue scale = 4.6 mm). The overall drain failure rate was 12.9%. The percentage of successful cases was 93.8% in malignant effusion, 93% in pneumothorax, and 92.3% in nonmalignant effusion; in the cases of pathologically diagnosed empyema, drains were more likely to get blocked (74.2%). We recorded 1 serious complication within the malignant effusion group. Wire-guided 12F Seldinger-type drains are a well-tolerated and effective method of treating pneumothorax and uncomplicated pleural effusions (malignant and nonmalignant) with acceptable morbidity. The use of 12F small-bore chest drain is not indicated for the treatment of empyema. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Value of MR contrast media in image-guided body interventions.

    PubMed

    Saeed, Maythem; Wilson, Mark

    2012-01-28

    In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability

  7. 9 CFR 390.3 - Indexes, reference guide, and handbook.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 2 2012-01-01 2012-01-01 false Indexes, reference guide, and handbook. 390.3 Section 390.3 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE ADMINISTRATIVE PROVISIONS FREEDOM OF INFORMATION AND PUBLIC INFORMATION § 390.3 Indexes, reference...

  8. 9 CFR 390.3 - Indexes, reference guide, and handbook.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 2 2014-01-01 2014-01-01 false Indexes, reference guide, and handbook. 390.3 Section 390.3 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE ADMINISTRATIVE PROVISIONS FREEDOM OF INFORMATION AND PUBLIC INFORMATION § 390.3 Indexes, reference...

  9. 9 CFR 390.3 - Indexes, reference guide, and handbook.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Indexes, reference guide, and handbook. 390.3 Section 390.3 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE ADMINISTRATIVE PROVISIONS FREEDOM OF INFORMATION AND PUBLIC INFORMATION § 390.3 Indexes, reference...

  10. 9 CFR 390.3 - Indexes, reference guide, and handbook.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 2 2013-01-01 2013-01-01 false Indexes, reference guide, and handbook. 390.3 Section 390.3 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF AGRICULTURE FOOD SAFETY AND INSPECTION SERVICE ADMINISTRATIVE PROVISIONS FREEDOM OF INFORMATION AND PUBLIC INFORMATION § 390.3 Indexes, reference...

  11. Guide to Permitting Hydrogen Motor Fuel Dispensing Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivkin, Carl; Buttner, William; Burgess, Robert

    2016-03-28

    The purpose of this guide is to assist project developers, permitting officials, code enforcement officials, and other parties involved in developing permit applications and approving the implementation of hydrogen motor fuel dispensing facilities. The guide facilitates the identification of the elements to be addressed in the permitting of a project as it progresses through the approval process; the specific requirements associated with those elements; and the applicable (or potentially applicable) codes and standards by which to determine whether the specific requirements have been met. The guide attempts to identify all applicable codes and standards relevant to the permitting requirements.

  12. Optically guided atom interferometer tuned to magic wavelength

    NASA Astrophysics Data System (ADS)

    Akatsuka, Tomoya; Takahashi, Tadahiro; Katori, Hidetoshi

    2017-11-01

    We demonstrate an atom interferometer operating on the 1S0-3P0 clock transition of 87Sr atoms in a “magic” optical guide, where the light shift perturbations of the guiding potential are canceled. As a proof-of-principle demonstration, a Mach-Zehnder interferometer is set horizontally to map the acceleration introduced by the focused optical guide. This magic guide interferometer on the clock transition is applicable to atomic elements where magic wavelengths can be found. Possible applications of the magic guide interferometer, including a hollow-core fiber interferometer and gradiometer, are discussed.

  13. Applications of near-infrared spectroscopy in food safety evaluation and control: a review of recent research advances.

    PubMed

    Qu, Jia-Huan; Liu, Dan; Cheng, Jun-Hu; Sun, Da-Wen; Ma, Ji; Pu, Hongbin; Zeng, Xin-An

    2015-01-01

    Food safety is a critical public concern, and has drawn great attention in society. Consequently, developments of rapid, robust, and accurate methods and techniques for food safety evaluation and control are required. As a nondestructive and convenient tool, near-infrared spectroscopy (NIRS) has been widely shown to be a promising technique for food safety inspection and control due to its huge advantages of speed, noninvasive measurement, ease of use, and minimal sample preparation requirement. This review presents the fundamentals of NIRS and focuses on recent advances in its applications, during the last 10 years of food safety control, in meat, fish and fishery products, edible oils, milk and dairy products, grains and grain products, fruits and vegetables, and others. Based upon these applications, it can be demonstrated that NIRS, combined with chemometric methods, is a powerful tool for food safety surveillance and for the elimination of the occurrence of food safety problems. Some disadvantages that need to be solved or investigated with regard to the further development of NIRS are also discussed.

  14. Recent trends in SELEX technique and its application to food safety monitoring

    PubMed Central

    Mei, Zhanlong; Yao, Li; Wang, Xin; Zheng, Lei; Liu, Jian; Liu, Guodong; Peng, Chifang; Chen, Wei

    2014-01-01

    The method referred to as “systemic evolution of ligands by exponential enrichment” (SELEX) was introduced in 1990 and ever since has become an important tool for the identification and screening of aptamers. Such nucleic acids can recognize and bind to their corresponding targets (analytes) with high selectivity and affinity, and aptamers therefore have become attractive alternatives to traditional antibodies not the least because they are much more stable. Meanwhile, they have found numerous applications in different fields including food quality and safety monitoring. This review first gives an introduction into the selection process and to the evolution of SELEX, then covers applications of aptamers in the surveillance of food safety (with subsections on absorptiometric, electrochemical, fluorescent and other methods), and then gives conclusions and perspectives. The SELEX method excels by its features of in vitro, high throughput and ease of operation. This review contains 86 references. PMID:25419005

  15. Investigating Safely: A Guide for High School Teachers

    ERIC Educational Resources Information Center

    Texley, Juliana; Kwan, Terry; Summers, John

    2004-01-01

    Just as high school science is more complex than it is at lower grade levels, so are the safety issues teachers face in their classes and labs. Reduce the risks to people and place with Investigating Safely, the third and most advanced and detailed volume in NSTA's unique series of safety guidebooks for science teachers. Some of the guides 11…

  16. Nuclear safety policy working group recommendations on nuclear propulsion safety for the space exploration initiative

    NASA Technical Reports Server (NTRS)

    Marshall, Albert C.; Lee, James H.; Mcculloch, William H.; Sawyer, J. Charles, Jr.; Bari, Robert A.; Cullingford, Hatice S.; Hardy, Alva C.; Niederauer, George F.; Remp, Kerry; Rice, John W.

    1993-01-01

    An interagency Nuclear Safety Working Group (NSPWG) was chartered to recommend nuclear safety policy, requirements, and guidelines for the Space Exploration Initiative (SEI) nuclear propulsion program. These recommendations, which are contained in this report, should facilitate the implementation of mission planning and conceptual design studies. The NSPWG has recommended a top-level policy to provide the guiding principles for the development and implementation of the SEI nuclear propulsion safety program. In addition, the NSPWG has reviewed safety issues for nuclear propulsion and recommended top-level safety requirements and guidelines to address these issues. These recommendations should be useful for the development of the program's top-level requirements for safety functions (referred to as Safety Functional Requirements). The safety requirements and guidelines address the following topics: reactor start-up, inadvertent criticality, radiological release and exposure, disposal, entry, safeguards, risk/reliability, operational safety, ground testing, and other considerations.

  17. System interface for an integrated intelligent safety system (ISS) for vehicle applications.

    PubMed

    Hannan, Mahammad A; Hussain, Aini; Samad, Salina A

    2010-01-01

    This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications.

  18. System Interface for an Integrated Intelligent Safety System (ISS) for Vehicle Applications

    PubMed Central

    Hannan, Mahammad A.; Hussain, Aini; Samad, Salina A.

    2010-01-01

    This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications. PMID:22205861

  19. Applications of GIS for highway safety : peer exchange summary report, Cambridge, MA, September 14-15, 2011

    DOT National Transportation Integrated Search

    2011-09-30

    On September 14-15, 2011, the FHWA's Office of Planning and its Office of Safety sponsored a 1.5-day peer exchange to promote the use of GIS and mapping for highway safety applications. This report offers overviews of the presentations given at the p...

  20. Agriculture & the Environment. Teacher's Guide.

    ERIC Educational Resources Information Center

    McMurry, Linda Maston

    This teacher's guide offers background information that teachers can use to incorporate topics related to agriculture and the environment into the curriculum. Classroom activities to bring these topics alive for students in grades 6-9 are suggested. Chapters include: (1) Pesticides and Integrated Pest Management; (2) Food Safety; (3) Water…

  1. A Guide Management System Based on RFID and Bluetooth Technology

    NASA Astrophysics Data System (ADS)

    Li, Han-Sheng; Wang, Jun-Jun

    The most fundamental and important requirement of the tour guide in the tour process is to ensure the safety of tourists. In this paper, a portable guide management system is designed based on RFID technology, the Android software and blue-tooth communication technology. Through this system, the guide can get real-time information if some tourists are l behind, and send text message or dial to those tourists who are l behind immediately. The system reduces the roll-calling time on the tourists, improves the tour guide work efficiency and service quality.

  2. Application of modified extended method in CREAM for safety inspector in coal mines

    NASA Astrophysics Data System (ADS)

    Wang, Jinhe; Zhang, Xiaohong; Zeng, Jianchao

    2018-01-01

    Safety inspector often performs duties in circumstances contributes to the oc currence of human failures. Therefore, the paper aims at quantifying human failure pro bability (HFP) of safety inspector during the coal mine operation with cognitive reliabi lity and error analysis method (CREAM). Whereas, some shortcomings of this approa ch that lacking considering the applicability of the common performance condition (C PC), and the subjective of evaluating CPC level which weaken the accuracy of the qua ntitative prediction results. A modified extended method in CREAM which is able to a ddress these difficulties with a CPC framework table is proposed, and the proposed me thodology is demonstrated by the virtue of a coal-mine accident example. The results a re expected to be useful in predicting HFP of safety inspector and contribute to the enh ancement of coal mine safety.

  3. 14 CFR 414.19 - Technical criteria for reviewing a safety approval application.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Technical criteria for reviewing a safety approval application. 414.19 Section 414.19 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL... regulations. (2) Government-developed or adopted standards. (3) Industry consensus performance-based criteria...

  4. Management of Intrauterine Arteriovenous Malformation (AVM) in 14 Patients by Sonographically Guided Tisseel Application.

    PubMed

    Bandura, Patrick; Rawnaq, Tamina; Holzknecht, Annette; Cetin, Emine; Reemts, Petra; Zoi, Panagiota; Schwärzler, Peter

    2018-02-01

     AVMs are rare tumorous vascular lesions derived from placental tissue that may present with massive post-partum hemorrhage (PPH) causing potentially life-threatening anemic shock. Current treatment options include the embolization of uterine arteries and emergency postpartum hysterectomy. We present a new form of minimally invasive, highly specific sonographically guided treatment in the form of the application of a human fibrin sealant leading to the instant cease of blood loss.  A management protocol was established and a case series of 14 patients is presented. Diagnosis by endovaginal color Doppler sonography is followed by the sonographically guided application of biological glue (TISSEEL ® ), thus allowing for super-selective occlusion of the feeding vessels.  The procedure was technically successful in all 14 patients, 3 of whom (21 %) had a repeated procedure after 4 - 7 days. The mean age (yrs.) of the patients was 31 (25 - 40), the gravity was median 2 (1 - 5) and the parity was median 1 (0 - 4), the lowest Hb value was on average 9.35 ± 2.25 (5.2 - 14.2) g/dl, the lowest Ht was on average 30.82 ± 6.02 (18 - 41 %). Spectral Doppler analysis revealed an average of 80.71 ± 11.2 (66 - 115) cm/sec for the maximal detectable PSV. In the period of 4 - 55 months after treatment, 7 patients (50 %) had 8 successful pregnancies and 2 miscarriages.  In PPH there is vital interest in timely diagnosis of the underlying cause, thus allowing fertility-sparing, minimally invasive and super-selective emergency treatment. In AVMs causing PPH, a positive impact on perinatal morbidity and mortality may be achieved by sonographically guided application of this biological glue. © Georg Thieme Verlag KG Stuttgart · New York.

  5. The SEURAT-1 approach towards animal free human safety assessment.

    PubMed

    Gocht, Tilman; Berggren, Elisabet; Ahr, Hans Jürgen; Cotgreave, Ian; Cronin, Mark T D; Daston, George; Hardy, Barry; Heinzle, Elmar; Hescheler, Jürgen; Knight, Derek J; Mahony, Catherine; Peschanski, Marc; Schwarz, Michael; Thomas, Russell S; Verfaillie, Catherine; White, Andrew; Whelan, Maurice

    2015-01-01

    SEURAT-1 is a European public-private research consortium that is working towards animal-free testing of chemical compounds and the highest level of consumer protection. A research strategy was formulated based on the guiding principle to adopt a toxicological mode-of-action framework to describe how any substance may adversely affect human health.The proof of the initiative will be in demonstrating the applicability of the concepts on which SEURAT-1 is built on three levels:(i) Theoretical prototypes for adverse outcome pathways are formulated based on knowledge already available in the scientific literature on investigating the toxicological mode-of-actions leading to adverse outcomes (addressing mainly liver toxicity);(ii)adverse outcome pathway descriptions are used as a guide for the formulation of case studies to further elucidate the theoretical model and to develop integrated testing strategies for the prediction of certain toxicological effects (i.e., those related to the adverse outcome pathway descriptions);(iii) further case studies target the application of knowledge gained within SEURAT-1 in the context of safety assessment. The ultimate goal would be to perform ab initio predictions based on a complete understanding of toxicological mechanisms. In the near-term, it is more realistic that data from innovative testing methods will support read-across arguments. Both scenarios are addressed with case studies for improved safety assessment. A conceptual framework for a rational integrated assessment strategy emerged from designing the case studies and is discussed in the context of international developments focusing on alternative approaches for evaluating chemicals using the new 21st century tools for toxicity testing.

  6. Application of color mixing for safety and quality inspection of agricultural products

    NASA Astrophysics Data System (ADS)

    Ding, Fujian; Chen, Yud-Ren; Chao, Kuanglin

    2005-11-01

    In this paper, color-mixing applications for food safety and quality was studied, including two-color mixing and three-color mixing. It was shown that the chromaticness of the visual signal resulting from two- or three-color mixing is directly related to the band ratio of light intensity at the two or three selected wavebands. An optical visual device using color mixing to implement the band ratio criterion was presented. Inspection through human vision assisted by an optical device that implements the band ratio criterion would offer flexibility and significant cost savings as compared to inspection with a multispectral machine vision system that implements the same criterion. Example applications of this optical color mixing technique were given for the inspection of chicken carcasses with various diseases and for the detection of chilling injury in cucumbers. Simulation results showed that discrimination by chromaticness that has a direct relation with band ratio can work very well with proper selection of the two or three narrow wavebands. This novel color mixing technique for visual inspection can be implemented on visual devices for a variety of applications, ranging from target detection to food safety inspection.

  7. Developing safety performance functions incorporating reliability-based risk measures.

    PubMed

    Ibrahim, Shewkar El-Bassiouni; Sayed, Tarek

    2011-11-01

    Current geometric design guides provide deterministic standards where the safety margin of the design output is generally unknown and there is little knowledge of the safety implications of deviating from these standards. Several studies have advocated probabilistic geometric design where reliability analysis can be used to account for the uncertainty in the design parameters and to provide a risk measure of the implication of deviation from design standards. However, there is currently no link between measures of design reliability and the quantification of safety using collision frequency. The analysis presented in this paper attempts to bridge this gap by incorporating a reliability-based quantitative risk measure such as the probability of non-compliance (P(nc)) in safety performance functions (SPFs). Establishing this link will allow admitting reliability-based design into traditional benefit-cost analysis and should lead to a wider application of the reliability technique in road design. The present application is concerned with the design of horizontal curves, where the limit state function is defined in terms of the available (supply) and stopping (demand) sight distances. A comprehensive collision and geometric design database of two-lane rural highways is used to investigate the effect of the probability of non-compliance on safety. The reliability analysis was carried out using the First Order Reliability Method (FORM). Two Negative Binomial (NB) SPFs were developed to compare models with and without the reliability-based risk measures. It was found that models incorporating the P(nc) provided a better fit to the data set than the traditional (without risk) NB SPFs for total, injury and fatality (I+F) and property damage only (PDO) collisions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. 75 FR 44051 - Resolicitation of Applications for the Railroad Safety Technology Program Grant Program (RS-TEC...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... have a public benefit of improved railroad safety and efficiency. The program makes available $50... projects * * * that have a public benefit of improved safety and network efficiency.'' To be eligible for... percent grantee, cost share (cash or in-kind) requirement. Applications that do not clearly indicate at...

  9. [MR-guided focused ultrasound. Current and future applications].

    PubMed

    Trumm, C G; Napoli, A; Peller, M; Clevert, D-A; Stahl, R; Reiser, M; Matzko, M

    2013-03-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier.

  10. Strand V: Education for Survival. Safety Education. Health Curriculum Materials. Grades 7-9.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Bureau of Secondary Curriculum Development.

    GRADES OR AGES: Grades 7-9. SUBJECT MATTER: Education for survival and safety education. ORGANIZATION AND PHYSICAL APPEARANCE: The guide is divided into eight sections: accident problems, safe behavior, safety in the home, safety in school, safety at work, safety in physical and recreational activities, safety in driving and walking, and safety in…

  11. In Vitro Evaluation of Sunscreen Safety: Effects of the Vehicle and Repeated Applications on Skin Permeation from Topical Formulations

    PubMed Central

    Parenti, Carmela

    2018-01-01

    The evaluation of UV-filter in vitro percutaneous absorption allows the estimation of the systemic exposure dose (SED) and the margin of safety (MoS) of sunscreen products. As both the vehicle and pattern of application may affect sunscreen safety and efficacy, we evaluated in vitro release and skin permeation of two widely used UV-filters, octylmethoxycinnamate (OMC) and butylmethoxydibenzoylmethane (BMBM) from topical formulations with different features (oil in water (O/W) emulsions with different viscosity, water in oil (W/O) emulsion, oils with different lipophilicity). To mimic in-use conditions, we carried out experiments repeating sunscreen application on the skin surface for three consecutive days. BMBM release from all these vehicles was very low, thus leading to poor skin permeation. The vehicle composition significantly affected OMC release and skin permeation, and slight increases of OMC permeation were observed after repeated applications. From skin permeation data, SED and MoS values of BMBM and OMC were calculated for all the investigated formulations after a single application and repeated applications. While MoS values of BMBM were always well beyond the accepted safety limit, the safety of sunscreen formulations containing OMC may depend on the vehicle composition and the application pattern. PMID:29495452

  12. Idaho Driver Education Instructional Guide. Revised.

    ERIC Educational Resources Information Center

    Idaho State Dept. of Education, Boise.

    This driver education instructional safety guide is organized in three sections: Driver Education; Motorcycle Education; and Driver Education for the Handicapped. The driver education section contains 10 units dealing with the following topics: parent orientation; student orientation; basic control skills; driver performance; driving regulations;…

  13. Time series modeling in traffic safety research.

    PubMed

    Lavrenz, Steven M; Vlahogianni, Eleni I; Gkritza, Konstantina; Ke, Yue

    2018-08-01

    The use of statistical models for analyzing traffic safety (crash) data has been well-established. However, time series techniques have traditionally been underrepresented in the corresponding literature, due to challenges in data collection, along with a limited knowledge of proper methodology. In recent years, new types of high-resolution traffic safety data, especially in measuring driver behavior, have made time series modeling techniques an increasingly salient topic of study. Yet there remains a dearth of information to guide analysts in their use. This paper provides an overview of the state of the art in using time series models in traffic safety research, and discusses some of the fundamental techniques and considerations in classic time series modeling. It also presents ongoing and future opportunities for expanding the use of time series models, and explores newer modeling techniques, including computational intelligence models, which hold promise in effectively handling ever-larger data sets. The information contained herein is meant to guide safety researchers in understanding this broad area of transportation data analysis, and provide a framework for understanding safety trends that can influence policy-making. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Application of Bayesian informative priors to enhance the transferability of safety performance functions.

    PubMed

    Farid, Ahmed; Abdel-Aty, Mohamed; Lee, Jaeyoung; Eluru, Naveen

    2017-09-01

    Safety performance functions (SPFs) are essential tools for highway agencies to predict crashes, identify hotspots and assess safety countermeasures. In the Highway Safety Manual (HSM), a variety of SPFs are provided for different types of roadway facilities, crash types and severity levels. Agencies, lacking the necessary resources to develop own localized SPFs, may opt to apply the HSM's SPFs for their jurisdictions. Yet, municipalities that want to develop and maintain their regional SPFs might encounter the issue of the small sample bias. Bayesian inference is being conducted to address this issue by combining the current data with prior information to achieve reliable results. It follows that the essence of Bayesian statistics is the application of informative priors, obtained from other SPFs or experts' experiences. In this study, we investigate the applicability of informative priors for Bayesian negative binomial SPFs for rural divided multilane highway segments in Florida and California. An SPF with non-informative priors is developed for each state and its parameters' distributions are assigned to the other state's SPF as informative priors. The performances of SPFs are evaluated by applying each state's SPFs to the other state. The analysis is conducted for both total (KABCO) and severe (KAB) crashes. As per the results, applying one state's SPF with informative priors, which are the other state's SPF independent variable estimates, to the latter state's conditions yields better goodness of fit (GOF) values than applying the former state's SPF with non-informative priors to the conditions of the latter state. This is for both total and severe crash SPFs. Hence, for localities where it is not preferred to develop own localized SPFs and adopt SPFs from elsewhere to cut down on resources, application of informative priors is shown to facilitate the process. Copyright © 2017 National Safety Council and Elsevier Ltd. All rights reserved.

  15. SOUTH CAROLINA GUIDE AND MINIMUM SPECIFICATIONS FOR MOBILE CLASSROOM UNITS.

    ERIC Educational Resources Information Center

    South Carolina State Education Finance Commission, Columbia. Office of Schoolhouse Planning.

    THIS GUIDE OF REQUIRED AND RECOMMENDED STANDARDS FOR MOBILE CLASSROOM UNITS IS INTENDED TO--(1) PROVIDE A GUIDE TO LOCAL SCHOOL AUTHORITIES TO ASSIST THEM IN DETERMINING THE FEASIBILITY OF MOBILE UNITS, (2) SET MINIMUM SAFETY AND UTILITY REQUIREMENTS FOR MOBILE UNITS, (3) ASSURE LOCAL SCHOOL AUTHORITIES OF A MOBILE UNIT MEETING THE ABOVE…

  16. Grammar-Guided Writing for AAC Users

    ERIC Educational Resources Information Center

    Hunnicutt, Sheri; Magnuson, Tina

    2007-01-01

    A method of grammar-guided writing has been devised to guide graphic sign users through the construction of text messages for use in e-mail and other applications with a remote receiver. The purpose is to promote morphologically and syntactically correct sentences. The available grammatical structures in grammar-guided writing are the highest…

  17. Ground Instructor Written Test Guide--Basic-Advanced. Revised 1972.

    ERIC Educational Resources Information Center

    Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.

    The test guide was prepared to assist applicants who are preparing for the Ground Instructor Written Test. It supersedes the 1967 examination guide. The guide outlines the scope of the basic aeronautical knowledge requirements for a ground instructor; acquaints the applicant with source material that may be used to acquire this basic knowledge;…

  18. Rationale and design of the GUIDE-IT study: Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure.

    PubMed

    Felker, G Michael; Ahmad, Tariq; Anstrom, Kevin J; Adams, Kirkwood F; Cooper, Lawton S; Ezekowitz, Justin A; Fiuzat, Mona; Houston-Miller, Nancy; Januzzi, James L; Leifer, Eric S; Mark, Daniel B; Desvigne-Nickens, Patrice; Paynter, Gayle; Piña, Ileana L; Whellan, David J; O'Connor, Christopher M

    2014-10-01

    The GUIDE-IT (Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure) study is designed to determine the safety, efficacy, and cost-effectiveness of a strategy of adjusting therapy with the goal of achieving and maintaining a target N-terminal pro-B-type natriuretic peptide (NT-proBNP) level of <1,000 pg/ml compared with usual care in high-risk patients with systolic heart failure (HF). Elevations in natriuretic peptide (NP) levels provide key prognostic information in patients with HF. Therapies proven to improve outcomes in patients with HF are generally associated with decreasing levels of NPs, and observational data show that decreases in NP levels over time are associated with favorable outcomes. Results from smaller prospective, randomized studies of this strategy thus far have been mixed, and current guidelines do not recommend serial measurement of NP levels to guide therapy in patients with HF. GUIDE-IT is a prospective, randomized, controlled, unblinded, multicenter clinical trial designed to randomize approximately 1,100 high-risk subjects with systolic HF (left ventricular ejection fraction ≤40%) to either usual care (optimized guideline-recommended therapy) or a strategy of adjusting therapy with the goal of achieving and maintaining a target NT-proBNP level of <1,000 pg/ml. Patients in either arm of the study are followed up at regular intervals and after treatment adjustments for a minimum of 12 months. The primary endpoint of the study is time to cardiovascular death or first hospitalization for HF. Secondary endpoints include time to cardiovascular death and all-cause mortality, cumulative mortality, health-related quality of life, resource use, cost-effectiveness, and safety. The GUIDE-IT study is designed to definitively assess the effects of an NP-guided strategy in high-risk patients with systolic HF on clinically relevant endpoints of mortality, hospitalization, quality of life, and medical resource

  19. Application of a digital technique in evaluating the reliability of shade guides.

    PubMed

    Cal, E; Sonugelen, M; Guneri, P; Kesercioglu, A; Kose, T

    2004-05-01

    There appears to be a need for a reliable method for quantification of tooth colour and analysis of shade. Therefore, the primary objective of this study was to show the applicability of graphic software in colour analysis and secondly to investigate the reliability of commercial shade guides produced by the same manufacturer, using this digital technique. After confirming the reliability and reproducibility of the digital method by using self-assessed coloured images, three shade guides of the same manufacturer were photographed in daylight and in studio environments with a digital camera and saved in tagged image file format (TIFF) format. Colour analysis of each photograph was performed using the Adobe Photoshop 4.0 graphic program. Luminosity, and red, green, blue (L and RGB) values of each shade tab of each shade guide were measured and the data were subjected to statistical analysis using the repeated measure Anova test. The L and RGB values of the images taken in daylight differed significantly from those of the images taken in studio environment (P < 0.05). In both environments, the luminosity and red values of the shade tabs were significantly different from each other (P < 0.05). It was concluded that, when the environmental conditions were kept constant, the Adobe Photoshop 4.0 colour analysis program could be used to analyse the colour of images. On the other hand, the results revealed that the accuracy of shade tabs widely being used in colour matching should be readdressed.

  20. Playground Perspectives: A Curriculum Guide for Promoting Playground Safety.

    ERIC Educational Resources Information Center

    Daugs, Donald R.; Fukui, Francine

    This curriculum guide is an interdisciplinary approach designed to reduce childhood accidental injuries on the playground. Materials are designed to provide background information and teaching resources for teachers that will be useable in a wide variety of environments. The first chapter provides a general background on playground hazards and…

  1. Environment, Safety, and Health Self-Assessment Report, Fiscal Year 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chernowski, John

    2009-02-27

    Lawrence Berkeley National Laboratory's Environment, Safety, and Health (ES&H) Self-Assessment Program ensures that Integrated Safety Management (ISM) is implemented institutionally and by all divisions. The Self-Assessment Program, managed by the Office of Contract Assurance (OCA), provides for an internal evaluation of all ES&H programs and systems at LBNL. The functions of the program are to ensure that work is conducted safely, and with minimal negative impact to workers, the public, and the environment. The Self-Assessment Program is also the mechanism used to institute continuous improvements to the Laboratory's ES&H programs. The program is described in LBNL/PUB 5344, Environment, Safety, andmore » Health Self-Assessment Program and is composed of four distinct assessments: the Division Self-Assessment, the Management of Environment, Safety, and Health (MESH) review, ES&H Technical Assurance, and the Appendix B Self-Assessment. The Division Self-Assessment uses the five core functions and seven guiding principles of ISM as the basis of evaluation. Metrics are created to measure performance in fulfilling ISM core functions and guiding principles, as well as promoting compliance with applicable regulations. The five core functions of ISM are as follows: (1) Define the Scope of Work; (2) Identify and Analyze Hazards; (3) Control the Hazards; (4) Perform the Work; and (5) Feedback and Improvement. The seven guiding principles of ISM are as follows: (1) Line Management Responsibility for ES&H; (2) Clear Roles and Responsibilities; (3) Competence Commensurate with Responsibilities; (4) Balanced Priorities; (5) Identification of ES&H Standards and Requirements; (6) Hazard Controls Tailored to the Work Performed; and (7) Operations Authorization. Performance indicators are developed by consensus with OCA, representatives from each division, and Environment, Health, and Safety (EH&S) Division program managers. Line management of each division performs the Division

  2. Defining attributes of patient safety through a concept analysis.

    PubMed

    Kim, Linda; Lyder, Courtney H; McNeese-Smith, Donna; Leach, Linda Searle; Needleman, Jack

    2015-11-01

    The aim of this study was to report an analysis of the concept of patient safety. Despite recent increase in the number of work being done to clarify the concept and standardize measurement of patient safety, there are still huge variations in how the term is conceptualized and how to measure patient safety data across various healthcare settings and in research. Concept analysis. A literature search was conducted through PubMed and Cumulative Index to Nursing and Allied Health Literature, Plus using the terms 'patient safety' in the title and 'concept analysis,' 'attributes' or 'definition' in the title and or abstract. All English language literature published between 2002-2014 were considered for the review. Walker and Avant's method guided this analysis. The defining attributes of patient safety include prevention of medical errors and avoidable adverse events, protection of patients from harm or injury and collaborative efforts by individual healthcare providers and a strong, well-integrated healthcare system. The application of Collaborative Alliance of Nursing Outcomes indicators as empirical referents would facilitate the measurement of patient safety. With the knowledge gained from this analysis, nurses may improve patient surveillance efforts that identify potential hazards before they become adverse events and have a stronger voice in health policy decision-making that influence implementation efforts aimed at promoting patient safety, worldwide. Further studies are needed on development of a conceptual model and framework that can aid with collection and measurement of standardized patient safety data. © 2015 John Wiley & Sons Ltd.

  3. Application of Framework for Integrating Safety, Security and Safeguards (3Ss) into the Design Of Used Nuclear Fuel Storage Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Badwan, Faris M.; Demuth, Scott F

    Department of Energy’s Office of Nuclear Energy, Fuel Cycle Research and Development develops options to the current commercial fuel cycle management strategy to enable the safe, secure, economic, and sustainable expansion of nuclear energy while minimizing proliferation risks by conducting research and development focused on used nuclear fuel recycling and waste management to meet U.S. needs. Used nuclear fuel is currently stored onsite in either wet pools or in dry storage systems, with disposal envisioned in interim storage facility and, ultimately, in a deep-mined geologic repository. The safe management and disposition of used nuclear fuel and/or nuclear waste is amore » fundamental aspect of any nuclear fuel cycle. Integrating safety, security, and safeguards (3Ss) fully in the early stages of the design process for a new nuclear facility has the potential to effectively minimize safety, proliferation, and security risks. The 3Ss integration framework could become the new national and international norm and the standard process for designing future nuclear facilities. The purpose of this report is to develop a framework for integrating the safety, security and safeguards concept into the design of Used Nuclear Fuel Storage Facility (UNFSF). The primary focus is on integration of safeguards and security into the UNFSF based on the existing Nuclear Regulatory Commission (NRC) approach to addressing the safety/security interface (10 CFR 73.58 and Regulatory Guide 5.73) for nuclear power plants. The methodology used for adaptation of the NRC safety/security interface will be used as the basis for development of the safeguards /security interface and later will be used as the basis for development of safety and safeguards interface. Then this will complete the integration cycle of safety, security, and safeguards. The overall methodology for integration of 3Ss will be proposed, but only the integration of safeguards and security will be applied to the design

  4. White Paper on studying the safety of the childhood immunization schedule in the Vaccine Safety Datalink.

    PubMed

    Glanz, Jason M; Newcomer, Sophia R; Jackson, Michael L; Omer, Saad B; Bednarczyk, Robert A; Shoup, Jo Ann; DeStefano, Frank; Daley, Matthew F

    2016-02-15

    While the large majority of parents in the U.S. vaccinate their children according to the recommended immunization schedule, some parents have refused or delayed vaccinating, often citing safety concerns. In response to public concern, the U.S. Institute of Medicine (IOM) evaluated existing research regarding the safety of the recommended immunization schedule. The IOM concluded that although available evidence strongly supported the safety of the currently recommended schedule as a whole, additional observational research was warranted to compare health outcomes between fully vaccinated children and those on a delayed or alternative schedule. In addition, the IOM identified the Vaccine Safety Datalink (VSD) as an important resource for conducting this research. Guided by the IOM findings, the Centers for Disease Control and Prevention (CDC) commissioned a White Paper to assess how the VSD could be used to study the safety of the childhood immunization schedule. Guided by subject matter expert engagement, the resulting White Paper outlines a 4 stage approach for identifying exposure groups of undervaccinated children, presents a list of health outcomes of highest priority to examine in this context, and describes various study designs and statistical methods that could be used to analyze the safety of the schedule. While it appears feasible to study the safety of the recommended immunization schedule in settings such as the VSD, these studies will be inherently complex, and as with all observational studies, will need to carefully address issues of confounding and bias. In light of these considerations, decisions about conducting studies of the safety of the schedule will also need to assess epidemiological evidence of potential adverse events that could be related to the schedule, the biological plausibility of an association between an adverse event and the schedule, and public concern about the safety of the schedule. Copyright © 2015 Elsevier Ltd. All rights

  5. Apply Pesticides Correctly, A Guide for Commercial Applicators: Industrial, Institutional, Structural and Health Related Pest Control.

    ERIC Educational Resources Information Center

    Wamsley, Mary Ann, Ed.; Vermeire, Donna M., Ed.

    This guide contains basic information to meet the specific standards for pesticide applicators. The thrust of this document is the recognition and control of common pests. Included are those which directly affect man such as bees, roaches, mites, and mosquitoes; and those which destroy food products and wooden structures. Both mechanical and…

  6. Vehicle-to-infrastructure (V2I) safety applications : performance requirements, vol. 1, introduction and common requirements.

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the first of a seven volume report that describes performance requirements for connected vehicle vehicle-to-infrastructure (V2I) Safety Applications developed for the U.S. Department of Transportation (U.S. DOT). The applications add...

  7. Recommended safety guides for industrial laboratories and shops

    NASA Technical Reports Server (NTRS)

    Allison, W. W.

    1971-01-01

    Booklet provides references to 29 publications providing information on hazard control and approved safety practices. Areas include pressurized gas and vacuum systems. Guidelines are presented for safeguarding facilities where machinery, equipment, electrical devices, or hazardous chemicals are used.

  8. Selective Guide to Literature on Software Review Sources. Engineering Literature Guides, Number 8.

    ERIC Educational Resources Information Center

    Bean, Margaret H., Ed.

    This selective literature guide serves as a directory to software evaluation sources for all sizes of microcomputers. Information is provided on review sources and guides which deal with a variety of applications such as library, engineering, school, and business as well as a variety of systems, including DOS and CP/M. This document is intended to…

  9. The Rock Climbing Teaching Guide.

    ERIC Educational Resources Information Center

    Kudlas, John

    The product of 10 years of rock climbing instruction, this guide provides material from which an instructor can teach basic climbing concepts and safety skills as well as conduct a safe, enjoyable rock climbing class in a high school setting. It is designed for an instructor with limited experience in climbing; however, the need for teacher…

  10. Making Patient Risk Visible: Implementation of a Nursing Document Information System to Improve Patient Safety.

    PubMed

    Wang, Panfeng; Zhang, Hongjun; Li, Baohua; Lin, Keke

    2016-01-01

    The aims of this study were to develop a nursing information system (NIS), enhance the visibility of patient risk, and identify challenges and facilitators to adoption of the NIS risk assessment system for nurse leaders. This article describes the function of a nursing risk assessment information system, and the results of a survey on the risk assessment system. The results suggested that quality of information processing in nursing significantly improved patient safety. Nurses surveyed demonstrated a high degree of satisfaction, with saving time and improving safety. The nursing document information system described was introduced to improve patient safety and decrease risk. The application of the system has greatly enhanced the efficiency of nursing work, and guides the nurses to make an accurate, comprehensive and objective assessment of patient information, contributing significantly to further improvement in care standards and care decisions.

  11. Integrating Occupational Health and Safety into TAFE Courses: Curriculum Topics.

    ERIC Educational Resources Information Center

    Hall, Bob; Mageean, Pauline

    This guide is designed to help technical and further education (TAFE) curriculum writers in Australia integrate safety education into vocational education courses. It provides a general overview of occupational health and safety from the perspective of TAFE trade training and a brief summary of the major health and safety issues that might be…

  12. Health Services Assistant. Revised. Instructor Guide.

    ERIC Educational Resources Information Center

    Missouri Univ., Columbia. Instructional Materials Lab.

    This color-coded curriculum guide was developed to help health services educators prepare students for health services occupations. The curriculum is organized in 20 units that cover the following topics: interpersonal relationships and the health care team; communication and observation skills; safety considerations; microbiology; the body as a…

  13. Training for Certification: Trainer's Guide.

    ERIC Educational Resources Information Center

    Mississippi State Univ., State College. Cooperative Extension Service.

    This Cooperative Extension Service publication from Mississippi State University is a teacher's guide for a private pesticide applicator certification training program. This guide is designed for use by county extension agents. Contents include: (1) a suggested training schedule; (2) stepwise instructions for implementation of the private…

  14. Magnetic resonance image guided transurethral ultrasound prostate ablation: a preclinical safety and feasibility study with 28-day followup.

    PubMed

    Burtnyk, Mathieu; Hill, Tracy; Cadieux-Pitre, Heather; Welch, Ian

    2015-05-01

    We determine the safety and feasibility of magnetic resonance image guided transurethral ultrasound prostate ablation using active temperature feedback control in a preclinical canine model with 28-day followup. After a long acclimatization period we performed ultrasound treatment in 8 subjects using the magnetic resonance image guided TULSA-PRO™ transurethral ultrasound prostate ablation system. Comprehensive examinations and observations were done before and throughout the 28-day followup, including assessment of clinically significant treatment related adverse events. In addition to gross pathology evaluation, extensive histopathological analysis was done to assess cell kill inside and outside the prostate. We evaluated prostate conformal heating by comparing the spatial difference between the treatment plan and the 55C isotherm measured on magnetic resonance imaging thermometry acquired during treatment. These findings were confirmed on contrast enhanced magnetic resonance imaging immediately after treatment and at 28 days. Clinically there were no adverse events in any of the 8 subjects throughout the 28-day followup. All subjects had normal urinary and bowel function. Gross necropsy and histology confirmed that the intended thermal cell kill was confined to the prostate. No surrounding tissue was damaged, including the rectum and the external urinary sphincter. Conformal heating was achieved with an average -0.9 mm accuracy and 0.9 mm precision. Contrast enhanced magnetic resonance imaging and histological analysis confirmed tissue ablation in targeted areas of the prostate. Urethral tissue was spared from thermal damage. Magnetic resonance image guided transurethral ultrasound is a safe, feasible procedure for accurate and precise conformal thermal ablation of prostate tissue, as demonstrated in a preclinical model with 28-day followup. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights

  15. MR-guided endovascular interventions: a comprehensive review on techniques and applications.

    PubMed

    Kos, Sebastian; Huegli, Rolf; Bongartz, Georg M; Jacob, Augustinus L; Bilecen, Deniz

    2008-04-01

    The magnetic resonance (MR) guidance of endovascular interventions is probably one of the greatest challenges of clinical MR research. MR angiography is not only an imaging tool for the vasculature but can also simultaneously depict high tissue contrast, including the differentiation of the vascular wall and perivascular tissues, as well as vascular function. Several hurdles had to be overcome to allow MR guidance for endovascular interventions. MR hardware and sequence design had to be developed to achieve acceptable patient access and to allow real-time or near real-time imaging. The development of interventional devices, both applicable and safe for MR imaging (MRI), was also mandatory. The subject of this review is to summarize the latest developments in real-time MRI hardware, MRI, visualization tools, interventional devices, endovascular tracking techniques, actual applications and safety issues.

  16. Architectural Drafting: Commercial Applications. Teacher Guide.

    ERIC Educational Resources Information Center

    Whitney, Terry A.

    This curriculum guide contains the technical information and tasks necessary for a student (who has already completed basic drafting) to be employed as an architectural drafter trainee. The curriculum is written in terms of student performance using measurable objectives, technical information, tasks developed to accomplish those objectives, and…

  17. Application of the SCALE TSUNAMI Tools for the Validation of Criticality Safety Calculations Involving 233U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, Don; Rearden, Bradley T; Hollenbach, Daniel F

    2009-02-01

    The Radiochemical Development Facility at Oak Ridge National Laboratory has been storing solid materials containing 233U for decades. Preparations are under way to process these materials into a form that is inherently safe from a nuclear criticality safety perspective. This will be accomplished by down-blending the {sup 233}U materials with depleted or natural uranium. At the request of the U.S. Department of Energy, a study has been performed using the SCALE sensitivity and uncertainty analysis tools to demonstrate how these tools could be used to validate nuclear criticality safety calculations of selected process and storage configurations. ISOTEK nuclear criticality safetymore » staff provided four models that are representative of the criticality safety calculations for which validation will be needed. The SCALE TSUNAMI-1D and TSUNAMI-3D sequences were used to generate energy-dependent k{sub eff} sensitivity profiles for each nuclide and reaction present in the four safety analysis models, also referred to as the applications, and in a large set of critical experiments. The SCALE TSUNAMI-IP module was used together with the sensitivity profiles and the cross-section uncertainty data contained in the SCALE covariance data files to propagate the cross-section uncertainties ({Delta}{sigma}/{sigma}) to k{sub eff} uncertainties ({Delta}k/k) for each application model. The SCALE TSUNAMI-IP module was also used to evaluate the similarity of each of the 672 critical experiments with each application. Results of the uncertainty analysis and similarity assessment are presented in this report. A total of 142 experiments were judged to be similar to application 1, and 68 experiments were judged to be similar to application 2. None of the 672 experiments were judged to be adequately similar to applications 3 and 4. Discussion of the uncertainty analysis and similarity assessment is provided for each of the four applications. Example upper subcritical limits (USLs) were

  18. Application of the Life Safety Code to a Historic Test Stand

    NASA Technical Reports Server (NTRS)

    Askins, Bruce; Lemke, Paul R.; Lewis, William L.; Covell, Carol C.

    2011-01-01

    . An effort was launched to thoroughly evaluate the applicable life safety requirements, examine the context in which they were derived, and determine a means by which the TS4550 modifications could be made within budget and on schedule, while still providing the occupants with appropriate levels of safety.

  19. School Transportation: A Guide for Supervisors.

    ERIC Educational Resources Information Center

    National Safety Council, Chicago, IL.

    This working guide for the school bus supervisor shows how to increase the safety and efficiency of school transportation. Guidelines are provided to help prevent accidents involving school buses and to establish sound operating policies for school transportation fleets. The booklet points out how any school transportation system can provide its…

  20. Safety of High Speed Magnetic Levitation Transportation Systems - Comparison of U.S. and Foreign Safety Requirements for Application to U.S. Maglev Systems

    DOT National Transportation Integrated Search

    1993-09-01

    This report presents the results of a systematic review of the safety requirements selected for the German Transrapid : electromagnetic (EMS) type maglev system to determine their applicability and completeness with respect to the : construction and ...

  1. Certification Processes for Safety-Critical and Mission-Critical Aerospace Software

    NASA Technical Reports Server (NTRS)

    Nelson, Stacy

    2003-01-01

    This document is a quick reference guide with an overview of the processes required to certify safety-critical and mission-critical flight software at selected NASA centers and the FAA. Researchers and software developers can use this guide to jumpstart their understanding of how to get new or enhanced software onboard an aircraft or spacecraft. The introduction contains aerospace industry definitions of safety and safety-critical software, as well as, the current rationale for certification of safety-critical software. The Standards for Safety-Critical Aerospace Software section lists and describes current standards including NASA standards and RTCA DO-178B. The Mission-Critical versus Safety-Critical software section explains the difference between two important classes of software: safety-critical software involving the potential for loss of life due to software failure and mission-critical software involving the potential for aborting a mission due to software failure. The DO-178B Safety-critical Certification Requirements section describes special processes and methods required to obtain a safety-critical certification for aerospace software flying on vehicles under auspices of the FAA. The final two sections give an overview of the certification process used at Dryden Flight Research Center and the approval process at the Jet Propulsion Lab (JPL).

  2. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  3. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  4. Nutrients: Learner's Guide for a Critical Path in Water Quality Monitoring.

    ERIC Educational Resources Information Center

    Glazer, Richard B.; And Others

    This learner's guide on nutrients is derived from a water monitoring curriculum developed at Ulster County Community College. There are 30 modules in this guide; each introduced with a statement of purpose and then broken down into an objective, learning conditions, and performance level. The modules cover: (1) safety; (2) chemical compounds; (3)…

  5. 76 FR 31467 - Guide Concerning Fuel Economy Advertising for New Automobiles

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-01

    ...The Federal Trade Commission (``FTC'' or ``Commission'') gives notice that it is postponing any amendments to its Guide Concerning Fuel Economy Advertising for New Automobiles (``Fuel Economy Guide'' or ``Guide'') pending completion of ongoing review by the Environmental Protection Agency (``EPA'') and the National Highway Traffic Safety Administration (``NHTSA'') of current fuel economy labeling requirements and the Commission's accelerated regulatory review of its own Labeling Requirements for Alternative Fuels and Alternative Fueled Vehicles Rule (``Alternative Fuels Rule'').

  6. Safety and efficacy of wavefront-guided myopic laser in situ keratomileusis using a new wavefront sensor technology: first 100 cases.

    PubMed

    Smadja, David; Santhiago, Marcony R; Tellouck, Joy; De Castro, Tania; Lecomte, Fanny; Mello, Glauco R; Touboul, David

    2015-08-01

    To evaluate the safety and efficacy of wavefront-guided laser in situ keratomileusis (LASIK) for the correction of low to high myopia and myopic astigmatism using data derived from a new-generation Hartmann-Shack aberrometer. Refractive Surgery Unit, Bordeaux Hospital University, France. Retrospective case series. This retrospective study analyzed the initial group of eyes treated with wavefront-guided LASIK for myopia and myopic astigmatism using the Visx S4IR excimer laser and wavefront data derived from a new Hartmann-Shack aberrometer (iDesign Advanced Wavescan aberrometer). Refractive (refraction and refractive accuracy) and visual outcomes (uncorrected [UDVA] and corrected [CDVA] distance visual acuities) were recorded 3 months postoperatively. The study included 100 eyes of 50 consecutively treated patients. The mean decimal UDVA improved from 0.1 ± 0.1 (SD) preoperatively to 1.1 ± 0.15 postoperatively (P < .01). A monocular UDVA of 20/16, 20/20, and 20/25 were achieved in 76.6%, 94.4%, and 96.6% of eyes, respectively. The postoperative manifest spherical equivalent was within ±0.5 diopter in all eyes. No eye lost 2 or more lines of CDVA, and 29.2% of the eyes gained 1 or more lines of CDVA. Wavefront-guided LASIK performed using data derived from the new Hartmann-Shack aberrometer was safe, effective, and predictable for treating myopia and myopic astigmatism. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. Efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

    PubMed

    Duan, Xu; Ling, Feng; Shen, Yun; Yang, Jun; Xu, Hai-ying; Tong, Xiao-shan

    2013-04-01

    We investigated the efficacy and safety of nitroglycerin for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation. A total of 40 consecutive patients referred for contrast-guided axillary vein puncture for pacemaker or defibrillator implantations were included in the study. Patients were randomly assigned to control group and nitroglycerin group. Patients in the nitroglycerin group were given 200 µg (2 mL) nitroglycerin via ipsilateral peripheral vein about 3 min before puncture. The degree of venous spasm was evaluated by the reduction in lumen calibre of the axillary vein after puncture. Mild venous spasm and severe venous spasm were defined as a reduction in lumen calibre of 50-90% and ≥ 90%, respectively. The mean degree of venous spasm of axillary vein was lower in the nitroglycerin group than in the control group (23.0 ± 22.3 vs. 45.5 ± 33.6%, P = 0.018). The incidence of mild or severe venous spasm was lower in the nitroglycerin group than in the control group (3/20 vs. 11/20, P = 0.019). In the nitroglycerin group, the systolic blood pressure had a significant decrease after puncture (129.5 ± 23.7 vs. 143.0 ± 24.1 mmHg, P = 0.003). There was no hypotension and other adverse reaction of nitroglycerin in the nitroglycerin group. Intravenous nitroglycerin is effective and safe for preventing venous spasm during contrast-guided axillary vein puncture for pacemaker or defibrillator leads implantation.

  8. Teaching Safety and Health in the Workplace. An Instructor's Guide.

    ERIC Educational Resources Information Center

    Occupational Safety and Health Administration, Washington, DC.

    The primary concern of the Occupational Safety and Health Act (OSHA) is to provide a safe and healthful workplace for every working man and woman in the nation. One way to help reduce the number of injuries and illnesses in the workplace is by training workers to be more aware of the job safety and health hazards and to teach them the methods of…

  9. A Field Guide to Constructivism in the College Science Classroom: Four Essential Criteria and a Guide to Their Usage

    ERIC Educational Resources Information Center

    Hartle, R. Todd; Baviskar, Sandhya; Smith, Rosemary

    2012-01-01

    This field guide provides four essential criteria for constructivism as well as a guide for using these criteria to identify and assess the level of constructivism being used in an educational experience. The criteria include: 1) prior knowledge, 2) cognitive dissonance, 3) application with feedback, and 4) metacognition. This guide provides…

  10. First noninvasive thermal ablation of a brain tumor with MR-guided focused ultrasound

    PubMed Central

    2014-01-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas its clinical application for tumor neurosurgery has been delayed for various technical and procedural reasons. Here, we report the case of a 63-year-old patient presenting with a centrally located recurrent glioblastoma who was included in our ongoing clinical phase I study aimed at evaluating the feasibility and safety of transcranial MRgFUS for brain tumor ablation. Applying 25 high-power sonications under MR imaging guidance, partial tumor ablation could be achieved without provoking neurological deficits or other adverse effects in the patient. This proves, for the first time, the feasibility of using transcranial MR-guided focused ultrasound to safely ablate substantial volumes of brain tumor tissue. PMID:25671132

  11. Fire! Fire Prevention and Safety: A Teacher's Handbook.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Div. of Educational Planning and Support.

    In this curriculum guide, guidelines for teaching children about fire safety and related topics and activities representing an interdisciplinary approach to fire safety are outlined. Major fire hazards and methods of dealing with them are described. Possible sites for field trips and films relating to fire are listed. The rules of the New York…

  12. Phenomenological Studies on Sodium for CSP Applications: A Safety Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armijo, Kenneth Miguel; Andraka, Charles E.

    Sodium as a heat transfer fluid (HTF) can achieve temperatures above 700°C to improve power cycle performance for reducing large infrastructure costs of high-temperature systems. Current concentrating solar power (CSP) sensible HTF’s (e.g. air, salts) have poor thermal conductivity, and thus low heat transfer capabilities, requiring a large receiver. The high thermal conductivity of sodium has demonstrated high heat transfer rates on dish and towers systems, which allow a reduction in receiver area by a factor of two to four, reducing re-radiation and convection losses and cost by a similar factor. Sodium produces saturated vapor at pressures suitable for transportmore » starting at 600°C and reaches one atmosphere at 870°C, providing a wide range of suitable latent operating conditions that match proposed high temperature, isothermal input power cycles. This advantage could increase the receiver and system efficiency while lowering the cost of CSP tower systems. Although there are a number of desirable thermal performance advantages associated with sodium, its propensity to rapidly oxidize presents safety challenges. This investigation presents a literature review that captures historical operations/handling lessons for advanced sodium systems, and the current state-of-knowledge related to sodium combustion behavior. Technical and operational solutions addressing sodium safety and applications in CSP will be discussed, including unique safety hazards and advantages using latent sodium. Operation and maintenance experience from the nuclear industry with sensible and latent systems will also be discussed in the context of safety challenges and risk mitigation solutions.« less

  13. Phenomenological studies on sodium for CSP applications: A safety review

    NASA Astrophysics Data System (ADS)

    Armijo, Kenneth M.; Andraka, Charles E.

    2016-05-01

    Sodium Heat transfer fluids (HTF) such as sodium, can achieve temperatures above 700°C to obtain power cycle performance improvements for reducing large infrastructure costs of high-temperature systems. Current concentrating solar power (CSP) sensible HTF's (e.g. air, salts) have poor thermal conductivity, and thus low heat transfer capabilities, requiring a large receiver. The high thermal conductivity of sodium has demonstrated high heat transfer rates on dish and towers systems, which allow a reduction in receiver area by a factor of two to four, reducing re-radiation and convection losses and cost by a similar factor. Sodium produces saturated vapor at pressures suitable for transport starting at 600°C and reaches one atmosphere at 870°C, providing a wide range of suitable operating conditions that match proposed high temperature, isothermal power cycles. This advantage could increase the efficiency while lowering the cost of CSP tower systems. Although there are a number of desirable thermal performance advantages associated with sensible sodium, its propensity to rapidly oxidize presents safety challenges. This investigation presents a literature review that captures historical operations/handling lessons for advanced sodium receiver designs, and the current state-of-knowledge related to sodium combustion behavior. Technical and operational solutions addressing sodium safety and applications in CSP will be discussed, including unique safety hazards and advantages using latent sodium. Lessons obtained from the nuclear industry with sensible and latent systems will also be discussed in the context of safety challenges and risk mitigation solutions.

  14. Refractive improvements and safety with topography-guided corneal crosslinking for keratoconus: 1-year results.

    PubMed

    Nordström, Maria; Schiller, Maria; Fredriksson, Anneli; Behndig, Anders

    2017-07-01

    To assess the refractive improvements and the corneal endothelial safety of an individualised topography-guided regimen for corneal crosslinking in progressive keratoconus. An open-label prospective randomised clinical trial was performed at the Department of Clinical Sciences, Ophthalmology, Umeå University Hospital, Umeå, Sweden. Thirty-seven patients (50 eyes) with progressive keratoconus planned for corneal crosslinking were included. The patients were randomised to topography-guided crosslinking (photorefractive intrastromal crosslinking (PiXL); n=25) or uniform 9 mm crosslinking (corneal collagen crosslinking (CXL); n=25). Visual acuity, refraction, keratometry (K1, K2 and K max ) and corneal endothelial morphometry were assessed preoperatively and at 1, 3, 6 and 12 months postoperatively. The PiXL treatment involved an asymmetrical treatment zone centred on the area of maximum corneal steepness with treatment energies ranging from 7.2 to 15.0 J/cm 2 ; the CXL treatment was a uniform 9 mm 5.4 J/cm 2 pulsed crosslinking. The main outcome measures were changes in refractive errors and corneal endothelial cell density. The spherical refractive errors decreased (p<0.05) and the visual acuity improved (p<0.01) at 3, 6 and 12 months after PiXL, but not after CXL. The between-groups differences, however, were not significant. K2 and K max decreased at 3, 6 and 12 months after PiXL (p<0.01), but not after CXL (p<0.01 when comparing the two treatments). No corneal endothelial cell loss was seen after either treatment. Individualised topography-based crosslinking treatment centred on the ectatic cone has the potential to improve the corneal shape in keratoconus with decreased spherical refractive errors and improved visual acuity, without damage to the corneal endothelium. NCT02514200, Results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  16. Soldering and brazing safety guide: A handbook on space practice for those involved in soldering and brazing

    NASA Astrophysics Data System (ADS)

    This manual provides those involved in welding and brazing with effective safety procedures for use in performance of their jobs. Hazards exist in four types of general soldering and brazing processes: (1) cleaning; (2) application of flux; (3) application of heat and filler metal; and (4) residue cleaning. Most hazards during those operations can be avoided by using care, proper ventilation, protective clothing and equipment. Specific process hazards for various methods of brazing and soldering are treated. Methods to check ventilation are presented as well as a check of personal hygiene and good maintenance practices are stressed. Several emergency first aid treatments are described.

  17. Pedestrian safety workshop : a focus on older adults, [instructor guide].

    DOT National Transportation Integrated Search

    2010-02-01

    This guides purpose is to aid you in preparing for, and teaching, the workshop. It is divided into four : sections and a set of appendices: : 1. Getting to know the workshop Suggested steps on how to orient yourself to the content, flow, and :...

  18. Super Safety and Health Day at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Employees take a look at this NASCAR auto being displayed during Super Safety and Health Day at KSC. Safety Day is a full day of NASA-sponsored, KSC and 45th Space Wing events involving a number of health and safety related activities: Displays, vendors, technical paper sessions, panel discussions, a keynote speaker, etc. The entire Center and Wing stand down to participate in the planned events. Safety Day is held annually to proactively increase awareness in safety and health among the government and contractor workforce population. The first guiding principle at KSC is '''Safety and Health First.''' KSC's number one goal is to '''Assure sound, safe and efficient practices and processes are in place for privatized/commercialized launch site processing.'''

  19. Super Safety and Health Day at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Center Director Roy Bridges talks to workers outside the Hazardous Maintenance Facility during Super Safety and Health Day at KSC. Safety Day is a full day of NASA-sponsored, KSC and 45th Space Wing events involving a number of health and safety related activities: Displays, vendors, technical paper sessions, panel discussions, a keynote speaker, etc. The entire Center and Wing stand down to participate in the planned events. Safety Day is held annually to proactively increase awareness in safety and health among the government and contractor workforce population. The first guiding principle at KSC is '''Safety and Health First.''' KSC's number one goal is to '''Assure sound, safe and efficient practices and processes are in place for privatized/commercialized launch site processing.'''

  20. Super Safety and Health Day at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    Employees gather around a demonstration by Florida Power and Light during Super Safety and Health Day at KSC. Safety Day is a full day of NASA-sponsored, KSC and 45th Space Wing events involving a number of health- and safety-related activities: Displays, vendors, technical paper sessions, panel discussions, a keynote speaker, etc. The entire Center and Wing stand down to participate in the planned events. Safety Day is held annually to proactively increase awareness in safety and health among the government and contractor workforce population. The first guiding principle at KSC is '''Safety and Health First.''' KSC's number one goal is to '''Assure sound, safe and efficient practices and processes are in place for privatized/commercialized launch site processing.'''

  1. Super Safety and Health Day at KSC

    NASA Technical Reports Server (NTRS)

    2000-01-01

    In an exhibit tent during Super Safety and Health Day at KSC, employees sample iced tea from a vendor. Safety Day is a full day of NASA-sponsored, KSC and 45th Space Wing events involving a number of health- and safety-related activities: Displays, vendors, technical paper sessions, panel discussions, a keynote speaker, etc. The entire Center and Wing stand down to participate in the planned events. Safety Day is held annually to proactively increase awareness in safety and health among the government and contractor workforce population. The first guiding principle at KSC is '''Safety and Health First.''' KSC's number one goal is to '''Assure sound, safe and efficient practices and processes are in place for privatized/commercialized launch site processing.'''

  2. Drying Beds. Sludge Treatment and Disposal Course #166. Instructor's Guide [and] Student Workbook.

    ERIC Educational Resources Information Center

    Klopping, Paul H.

    Provided in this lesson is introductory material on sand and surfaced sludge drying beds. Typical construction and operation, proper maintenance, and safety procedures are considered. The lesson includes an instructor's guide and student workbook. The instructor's guide contains a description of the lesson, estimated presentation time,…

  3. 14 CFR 415.33 - Safety organization.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Safety organization. 415.33 Section 415.33....33 Safety organization. (a) An applicant shall maintain a safety organization and document it by... communication, both within the applicant's organization and between the applicant and any federal launch range...

  4. Arizona Traffic Safety Education, K-8. Grade 4.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic skills, this curriculum guide for grade 4 deals with the how and why of traffic safety. Based on the introduction to highway safety rules and laws that students have mastered in grades K through 3, the program for grades 4 through…

  5. Arizona Traffic Safety Education, K-8. Grade 5.

    ERIC Educational Resources Information Center

    Mesa Public Schools, AZ.

    One in a series designed to assist Arizona elementary and junior high school teachers in developing children's traffic skills, this curriculum guide for grade 5 deals with the how and why of traffic safety. Based on the introduction to highway safety rules and laws that students have mastered in grades K through 3, the program for grades 4 through…

  6. Safety management vs. picking leaves.

    PubMed

    Wright, D

    1991-09-01

    A safety program will generally have as its base a comprehensive written document made available for everyone in the organization. The document should indicate a positive commitment to safety by management. It should not be a "how to" guide, but rather a broad outline to establish responsibilities, goals, and methods. The safety manager is appointed in writing and answers to the highest level of management. As opposed to a "doer," the safety manager acts as a director and administrator of the safety program. This is accomplished through the advisory capacity of the safety program for solicited and unsolicited problems. The focus of the safety manager is on the system and how it contributes to safety problems, rather than individual problems. Management has the ultimate responsibility for safety. Their efforts should reflect a proactive attitude to correct problems in the system. In order to identify areas of interest, technically competent input from the safety manager should be required. The support of the safety program by top management determines the success of the program. Without a clear and firm commitment by the organization, safety will receive no more than lip service from the employees. The benefits of a proactive approach will be realized in the organization's ability to manage safety issues, rather than reacting to them.

  7. Occupant restraint legislation handbook : a guide for proponents

    DOT National Transportation Integrated Search

    1979-02-01

    The document is intended to serve as a working guide to individuals and organizations involved in efforts to gain legislative approval of general safety belt usage laws or child restraint laws. The information contained in this handbook falls into tw...

  8. RFID Application Strategy in Agri-Food Supply Chain Based on Safety and Benefit Analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Li, Peichong

    Agri-food supply chain management (SCM), a management method to optimize internal costs and productivities, has evolved as an application of e-business technologies. These days, RFID has been widely used in many fields. In this paper, we analyze the characteristics of agri-food supply chain. Then the disadvantages of RFID are discussed. After that, we study the application strategies of RFID based on benefit and safety degree.

  9. Kids and Chemistry: Large Event Guide.

    ERIC Educational Resources Information Center

    Tinnesand, Michael

    This guide is intended to provide Kids and Chemistry (K&C) with a variety of age-appropriate, fun, and safe demonstrations. It features information on planning a large event and includes safety guidelines. Several activities are included under each major topic. Topics include: (1) Acids and Bases; (2) Unsigned; (3) Kool Tie-Dye; (4) Secret…

  10. Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…

  11. Microbial food safety - modeling and applications

    USDA-ARS?s Scientific Manuscript database

    Microbial food safety is a key issue for the food processing industry, and enhancing food safety is everyone’s responsibility from food producers to consumers. Financial losses to the economy due to foodborne illness are in the billions of dollars, annually. Foodborne illness can be caused by patho...

  12. The Implementation and Maintenance of a Behavioral Safety Process in a Petroleum Refinery

    ERIC Educational Resources Information Center

    Myers, Wanda V.; McSween, Terry E.; Medina, Rixio E.; Rost, Kristen; Alvero, Alicia M.

    2010-01-01

    A values-centered and team-based behavioral safety process was implemented in a petroleum oil refinery. Employee teams defined the refinery's safety values and related practices, which were used to guide the process design and implementation. The process included (a) a safety assessment; (b) the clarification of safety-related values and related…

  13. Computer & manual accident typing for bicyclist accidents : administrator's guide

    DOT National Transportation Integrated Search

    1983-01-01

    This guide provides guidelines and procedures for classifying and analyzing bicyclist-motor vehicle accidents. The approach described herein is part of a systematic effort by the National Highway Traffic Safety Administration (NHTSA) to assist states...

  14. Robust remote-pumping sodium laser for advanced LIDAR and guide star applications

    NASA Astrophysics Data System (ADS)

    Ernstberger, Bernhard; Enderlein, Martin; Friedenauer, Axel; Schwerdt, Robin; Wei, Daoping; Karpov, Vladimir; Leisching, Patrick; Clements, Wallace R. L.; Kaenders, Wilhelm G.

    2015-10-01

    /min and an overall power consumption of < 700 W, the system offers a maximum of flexibility with minimal infrastructure demands on site. Each system is built in a modular way, based on the concept of line-replaceable units (LRU). A comprehensive system software, as well as an intuitive service GUI, allow for remote control and error tracking down to at least the LRU level. In case of a failure, any LRU can be easily replaced. With these fiber-based guide star lasers, TOPTICA for the first time offers a fully engineered, off-the-shelf guide star laser system for groundbased optical telescopes providing convenient, turn-key operation in remote and harsh locations. Reliability and flexibility will be beneficial in particular for advanced satellite and space debris tracking as well as LIDAR applications.

  15. A Guide to Collaboration for IEP Teams

    ERIC Educational Resources Information Center

    Martin, Nicholas R. M.

    2005-01-01

    With so many complex, challenging, and emotionally charged decisions involved, participating in an IEP meeting can seem like navigating through a minefield. But now there is a practical guide to managing these meetings with a high level of awareness, safety, and confidence. Developed for administrators, teachers, resource professionals, and…

  16. Safety and tolerability of MRI-guided infusion of AAV2-hAADC into the mid-brain of nonhuman primate

    PubMed Central

    Sebastian, Waldy San; Kells, Adrian P; Bringas, John; Samaranch, Lluis; Hadaczek, Piotr; Ciesielska, Agnieszka; Macayan, Michael J; Pivirotto, Phillip J; Forsayeth, John; Osborne, Sheryl; Wright, J Fraser; Green, Foad; Heller, Gregory; Bankiewicz, Krystof S

    2014-01-01

    Aromatic L-amino acid decarboxylase (AADC) deficiency is a rare, autosomal-recessive neurological disorder caused by mutations in the DDC gene that leads to an inability to synthesize catecholamines and serotonin. As a result, patients suffer compromised development, particularly in motor function. A recent gene replacement clinical trial explored putaminal delivery of recombinant adeno-associated virus serotype 2 vector encoding human AADC (AAV2-hAADC) in AADC-deficient children. Unfortunately, patients presented only modest amelioration of motor symptoms, which authors acknowledged could be due to insufficient transduction of putamen. We hypothesize that, with the development of a highly accurate MRI-guided cannula placement technology, a more effective approach might be to target the affected mid-brain neurons directly. Transduction of AADC-deficient dopaminergic neurons in the substantia nigra and ventral tegmental area with locally infused AAV2-hAADC would be expected to lead to restoration of normal dopamine levels in affected children. The objective of this study was to assess the long-term safety and tolerability of bilateral AAV2-hAADC MRI-guided pressurized infusion into the mid-brain of nonhuman primates. Animals received either vehicle, low or high AAV2-hAADC vector dose and were euthanized 1, 3, or 9 months after surgery. Our data indicate that effective mid-brain transduction was achieved without untoward effects. PMID:25541617

  17. Health Education Resource Guide, Junior High.

    ERIC Educational Resources Information Center

    Federal Way School District 210, WA.

    As part of a health education program for K-12, this curriculum guide for grade eight provides: (1) a short overview of health education; (2) a scope and sequence chart which lists specific topics to teach on mental health, physical health, community health, and safety that are appropriate at different grade levels; (3) a list of objectives; and…

  18. Section 4 User Guide – Primary Support

    EPA Pesticide Factsheets

    This document presents the user guide for the Office of Pollution Prevention and Toxics (OPPT) Section 4 application submission process. This document is the user guide for the Primary Support user of the Section 4 tool.

  19. The Role of Safety Culture in Influencing Provider Perceptions of Patient Safety.

    PubMed

    Bishop, Andrea C; Boyle, Todd A

    2016-12-01

    To determine how provider perceptions of safety culture influence their involvement in patient safety practices. Health-care providers were surveyed in 2 tertiary hospitals located in Atlantic Canada, composed of 4 units in total. The partial least squares (PLS) approach to structural equation modeling was used to analyze the data. Latent variables provider PLS model encompassed the hypothesized relationships between provider characteristics, safety culture, perceptions of patient safety practices, and actual performance of patient safety practices, using the Health Belief Model (HBM) as a guide. Data analysis was conducted using SmartPLS. A total of 113 health-care providers completed a survey out of an eligible 318, representing a response rate of 35.5%. The final PLS model showed acceptable internal consistency with all four latent variables having a composite reliability score above the recommended 0.70 cutoff value (safety culture = 0.86, threat = 0.76, expectations = 0.83, PS practices = 0.75). Discriminant validity was established, and all path coefficients were found to be significant at the α = 0.05 level using nonparametric bootstrapping. The survey results show that safety culture accounted for 34% of the variance in perceptions of threat and 42% of the variance in expectations. This research supports the role that safety culture plays in the promotion and maintenance of patient safety activities for health-care providers. As such, it is recommended that the introduction of new patient safety strategies follow a thorough exploration of an organization's safety culture.

  20. 75 FR 35508 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-22

    ... Systems and Networks,'' requires licensees to develop cyber-security plans and programs to protect critical digital assets, including digital safety systems, from malicious cyber attacks. Regulatory Guide 5.71, ``Cyber Security Programs for Nuclear Facilities,'' provides guidance to meet the requirements of...