Sample records for safety critical applications

  1. Aluminum Data Measurements and Evaluation for Criticality Safety Applications

    NASA Astrophysics Data System (ADS)

    Leal, L. C.; Guber, K. H.; Spencer, R. R.; Derrien, H.; Wright, R. Q.

    2002-12-01

    The Defense Nuclear Facility Safety Board (DNFSB) Recommendation 93-2 motivated the US Department of Energy (DOE) to develop a comprehensive criticality safety program to maintain and to predict the criticality of systems throughout the DOE complex. To implement the response to the DNFSB Recommendation 93-2, a Nuclear Criticality Safety Program (NCSP) was created including the following tasks: Critical Experiments, Criticality Benchmarks, Training, Analytical Methods, and Nuclear Data. The Nuclear Data portion of the NCSP consists of a variety of differential measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) at the Oak Ridge National Laboratory (ORNL), data analysis and evaluation using the generalized least-squares fitting code SAMMY in the resolved, unresolved, and high energy ranges, and the development and benchmark testing of complete evaluations for a nuclide for inclusion into the Evaluated Nuclear Data File (ENDF/B). This paper outlines the work performed at ORNL to measure, evaluate, and test the nuclear data for aluminum for applications in criticality safety problems.

  2. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  3. Software Safety Risk in Legacy Safety-Critical Computer Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice; Baggs, Rhoda

    2007-01-01

    Safety-critical computer systems must be engineered to meet system and software safety requirements. For legacy safety-critical computer systems, software safety requirements may not have been formally specified during development. When process-oriented software safety requirements are levied on a legacy system after the fact, where software development artifacts don't exist or are incomplete, the question becomes 'how can this be done?' The risks associated with only meeting certain software safety requirements in a legacy safety-critical computer system must be addressed should such systems be selected as candidates for reuse. This paper proposes a method for ascertaining formally, a software safety risk assessment, that provides measurements for software safety for legacy systems which may or may not have a suite of software engineering documentation that is now normally required. It relies upon the NASA Software Safety Standard, risk assessment methods based upon the Taxonomy-Based Questionnaire, and the application of reverse engineering CASE tools to produce original design documents for legacy systems.

  4. Robust optical sensors for safety critical automotive applications

    NASA Astrophysics Data System (ADS)

    De Locht, Cliff; De Knibber, Sven; Maddalena, Sam

    2008-02-01

    Optical sensors for the automotive industry need to be robust, high performing and low cost. This paper focuses on the impact of automotive requirements on optical sensor design and packaging. Main strategies to lower optical sensor entry barriers in the automotive market include: Perform sensor calibration and tuning by the sensor manufacturer, sensor test modes on chip to guarantee functional integrity at operation, and package technology is key. As a conclusion, optical sensor applications are growing in automotive. Optical sensor robustness matured to the level of safety critical applications like Electrical Power Assisted Steering (EPAS) and Drive-by-Wire by optical linear arrays based systems and Automated Cruise Control (ACC), Lane Change Assist and Driver Classification/Smart Airbag Deployment by camera imagers based systems.

  5. Application of the SCALE TSUNAMI Tools for the Validation of Criticality Safety Calculations Involving 233U

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, Don; Rearden, Bradley T; Hollenbach, Daniel F

    2009-02-01

    The Radiochemical Development Facility at Oak Ridge National Laboratory has been storing solid materials containing 233U for decades. Preparations are under way to process these materials into a form that is inherently safe from a nuclear criticality safety perspective. This will be accomplished by down-blending the {sup 233}U materials with depleted or natural uranium. At the request of the U.S. Department of Energy, a study has been performed using the SCALE sensitivity and uncertainty analysis tools to demonstrate how these tools could be used to validate nuclear criticality safety calculations of selected process and storage configurations. ISOTEK nuclear criticality safetymore » staff provided four models that are representative of the criticality safety calculations for which validation will be needed. The SCALE TSUNAMI-1D and TSUNAMI-3D sequences were used to generate energy-dependent k{sub eff} sensitivity profiles for each nuclide and reaction present in the four safety analysis models, also referred to as the applications, and in a large set of critical experiments. The SCALE TSUNAMI-IP module was used together with the sensitivity profiles and the cross-section uncertainty data contained in the SCALE covariance data files to propagate the cross-section uncertainties ({Delta}{sigma}/{sigma}) to k{sub eff} uncertainties ({Delta}k/k) for each application model. The SCALE TSUNAMI-IP module was also used to evaluate the similarity of each of the 672 critical experiments with each application. Results of the uncertainty analysis and similarity assessment are presented in this report. A total of 142 experiments were judged to be similar to application 1, and 68 experiments were judged to be similar to application 2. None of the 672 experiments were judged to be adequately similar to applications 3 and 4. Discussion of the uncertainty analysis and similarity assessment is provided for each of the four applications. Example upper subcritical limits (USLs) were

  6. Surveying wearable human assistive technology for life and safety critical applications: standards, challenges and opportunities.

    PubMed

    Alam, Muhammad Mahtab; Ben Hamida, Elyes

    2014-05-23

    In this survey a new application paradigm life and safety for critical operations and missions using wearable Wireless Body Area Networks (WBANs) technology is introduced. This paradigm has a vast scope of applications, including disaster management, worker safety in harsh environments such as roadside and building workers, mobile health monitoring, ambient assisted living and many more. It is often the case that during the critical operations and the target conditions, the existing infrastructure is either absent, damaged or overcrowded. In this context, it is envisioned that WBANs will enable the quick deployment of ad-hoc/on-the-fly communication networks to help save many lives and ensuring people's safety. However, to understand the applications more deeply and their specific characteristics and requirements, this survey presents a comprehensive study on the applications scenarios, their context and specific requirements. It explores details of the key enabling standards, existing state-of-the-art research studies, and projects to understand their limitations before realizing aforementioned applications. Application-specific challenges and issues are discussed comprehensively from various perspectives and future research and development directions are highlighted as an inspiration for new innovative solutions. To conclude, this survey opens up a good opportunity for companies and research centers to investigate old but still new problems, in the realm of wearable technologies, which are increasingly evolving and getting more and more attention recently.

  7. Surveying Wearable Human Assistive Technology for Life and Safety Critical Applications: Standards, Challenges and Opportunities

    PubMed Central

    Alam, Muhammad Mahtab; Ben Hamida, Elyes

    2014-01-01

    In this survey a new application paradigm life and safety for critical operations and missions using wearable Wireless Body Area Networks (WBANs) technology is introduced. This paradigm has a vast scope of applications, including disaster management, worker safety in harsh environments such as roadside and building workers, mobile health monitoring, ambient assisted living and many more. It is often the case that during the critical operations and the target conditions, the existing infrastructure is either absent, damaged or overcrowded. In this context, it is envisioned that WBANs will enable the quick deployment of ad-hoc/on-the-fly communication networks to help save many lives and ensuring people's safety. However, to understand the applications more deeply and their specific characteristics and requirements, this survey presents a comprehensive study on the applications scenarios, their context and specific requirements. It explores details of the key enabling standards, existing state-of-the-art research studies, and projects to understand their limitations before realizing aforementioned applications. Application-specific challenges and issues are discussed comprehensively from various perspectives and future research and development directions are highlighted as an inspiration for new innovative solutions. To conclude, this survey opens up a good opportunity for companies and research centers to investigate old but still new problems, in the realm of wearable technologies, which are increasingly evolving and getting more and more attention recently. PMID:24859024

  8. CRITICALITY SAFETY CONTROLS AND THE SAFETY BASIS AT PFP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kessler, S

    2009-04-21

    With the implementation of DOE Order 420.1B, Facility Safety, and DOE-STD-3007-2007, 'Guidelines for Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities', a new requirement was imposed that all criticality safety controls be evaluated for inclusion in the facility Documented Safety Analysis (DSA) and that the evaluation process be documented in the site Criticality Safety Program Description Document (CSPDD). At the Hanford site in Washington State the CSPDD, HNF-31695, 'General Description of the FH Criticality Safety Program', requires each facility develop a linking document called a Criticality Control Review (CCR) to document performance of these evaluations. Chapter 5,more » Appendix 5B of HNF-7098, Criticality Safety Program, provided an example of a format for a CCR that could be used in lieu of each facility developing its own CCR. Since the Plutonium Finishing Plant (PFP) is presently undergoing Deactivation and Decommissioning (D&D), new procedures are being developed for cleanout of equipment and systems that have not been operated in years. Existing Criticality Safety Evaluations (CSE) are revised, or new ones written, to develop the controls required to support D&D activities. Other Hanford facilities, including PFP, had difficulty using the basic CCR out of HNF-7098 when first implemented. Interpretation of the new guidelines indicated that many of the controls needed to be elevated to TSR level controls. Criterion 2 of the standard, requiring that the consequence of a criticality be examined for establishing the classification of a control, was not addressed. Upon in-depth review by PFP Criticality Safety staff, it was not clear that the programmatic interpretation of criterion 8C could be applied at PFP. Therefore, the PFP Criticality Safety staff decided to write their own CCR. The PFP CCR provides additional guidance for the evaluation team to use by clarifying the evaluation criteria in DOE-STD-3007

  9. SRTC criticality safety technical review: Nuclear Criticality Safety Evaluation 93-04 enriched uranium receipt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rathbun, R.

    Review of NMP-NCS-930087, {open_quotes}Nuclear Criticality Safety Evaluation 93-04 Enriched Uranium Receipt (U), July 30, 1993, {close_quotes} was requested of SRTC (Savannah River Technology Center) Applied Physics Group. The NCSE is a criticality assessment to determine the mass limit for Engineered Low Level Trench (ELLT) waste uranium burial. The intent is to bury uranium in pits that would be separated by a specified amount of undisturbed soil. The scope of the technical review, documented in this report, consisted of (1) an independent check of the methods and models employed, (2) independent HRXN/KENO-V.a calculations of alternate configurations, (3) application of ANSI/ANS 8.1,more » and (4) verification of WSRC Nuclear Criticality Safety Manual procedures. The NCSE under review concludes that a 500 gram limit per burial position is acceptable to ensure the burial site remains in a critically safe configuration for all normal and single credible abnormal conditions. This reviewer agrees with that conclusion.« less

  10. Verification of MCNP6.2 for Nuclear Criticality Safety Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Forrest B.; Rising, Michael Evan; Alwin, Jennifer Louise

    2017-05-10

    Several suites of verification/validation benchmark problems were run in early 2017 to verify that the new production release of MCNP6.2 performs correctly for nuclear criticality safety applications (NCS). MCNP6.2 results for several NCS validation suites were compared to the results from MCNP6.1 [1] and MCNP6.1.1 [2]. MCNP6.1 is the production version of MCNP® released in 2013, and MCNP6.1.1 is the update released in 2014. MCNP6.2 includes all of the standard features for NCS calculations that have been available for the past 15 years, along with new features for sensitivity-uncertainty based methods for NCS validation [3]. Results from the benchmark suitesmore » were compared with results from previous verification testing [4-8]. Criticality safety analysts should consider testing MCNP6.2 on their particular problems and validation suites. No further development of MCNP5 is planned. MCNP6.1 is now 4 years old, and MCNP6.1.1 is now 3 years old. In general, released versions of MCNP are supported only for about 5 years, due to resource limitations. All future MCNP improvements, bug fixes, user support, and new capabilities are targeted only to MCNP6.2 and beyond.« less

  11. Software development for safety-critical medical applications

    NASA Technical Reports Server (NTRS)

    Knight, John C.

    1992-01-01

    There are many computer-based medical applications in which safety and not reliability is the overriding concern. Reduced, altered, or no functionality of such systems is acceptable as long as no harm is done. A precise, formal definition of what software safety means is essential, however, before any attempt can be made to achieve it. Without this definition, it is not possible to determine whether a specific software entity is safe. A set of definitions pertaining to software safety will be presented and a case study involving an experimental medical device will be described. Some new techniques aimed at improving software safety will also be discussed.

  12. Certification Processes for Safety-Critical and Mission-Critical Aerospace Software

    NASA Technical Reports Server (NTRS)

    Nelson, Stacy

    2003-01-01

    This document is a quick reference guide with an overview of the processes required to certify safety-critical and mission-critical flight software at selected NASA centers and the FAA. Researchers and software developers can use this guide to jumpstart their understanding of how to get new or enhanced software onboard an aircraft or spacecraft. The introduction contains aerospace industry definitions of safety and safety-critical software, as well as, the current rationale for certification of safety-critical software. The Standards for Safety-Critical Aerospace Software section lists and describes current standards including NASA standards and RTCA DO-178B. The Mission-Critical versus Safety-Critical software section explains the difference between two important classes of software: safety-critical software involving the potential for loss of life due to software failure and mission-critical software involving the potential for aborting a mission due to software failure. The DO-178B Safety-critical Certification Requirements section describes special processes and methods required to obtain a safety-critical certification for aerospace software flying on vehicles under auspices of the FAA. The final two sections give an overview of the certification process used at Dryden Flight Research Center and the approval process at the Jet Propulsion Lab (JPL).

  13. 2011 Annual Criticality Safety Program Performance Summary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrea Hoffman

    The 2011 review of the INL Criticality Safety Program has determined that the program is robust and effective. The review was prepared for, and fulfills Contract Data Requirements List (CDRL) item H.20, 'Annual Criticality Safety Program performance summary that includes the status of assessments, issues, corrective actions, infractions, requirements management, training, and programmatic support.' This performance summary addresses the status of these important elements of the INL Criticality Safety Program. Assessments - Assessments in 2011 were planned and scheduled. The scheduled assessments included a Criticality Safety Program Effectiveness Review, Criticality Control Area Inspections, a Protection of Controlled Unclassified Information Inspection,more » an Assessment of Criticality Safety SQA, and this management assessment of the Criticality Safety Program. All of the assessments were completed with the exception of the 'Effectiveness Review' for SSPSF, which was delayed due to emerging work. Although minor issues were identified in the assessments, no issues or combination of issues indicated that the INL Criticality Safety Program was ineffective. The identification of issues demonstrates the importance of an assessment program to the overall health and effectiveness of the INL Criticality Safety Program. Issues and Corrective Actions - There are relatively few criticality safety related issues in the Laboratory ICAMS system. Most were identified by Criticality Safety Program assessments. No issues indicate ineffectiveness in the INL Criticality Safety Program. All of the issues are being worked and there are no imminent criticality concerns. Infractions - There was one criticality safety related violation in 2011. On January 18, 2011, it was discovered that a fuel plate bundle in the Nuclear Materials Inspection and Storage (NMIS) facility exceeded the fissionable mass limit, resulting in a technical safety requirement (TSR) violation. The TSR limits

  14. ESAS Deliverable PS 1.1.2.3: Customer Survey on Code Generations in Safety-Critical Applications

    NASA Technical Reports Server (NTRS)

    Schumann, Johann; Denney, Ewen

    2006-01-01

    Automated code generators (ACG) are tools that convert a (higher-level) model of a software (sub-)system into executable code without the necessity for a developer to actually implement the code. Although both commercially supported and in-house tools have been used in many industrial applications, little data exists on how these tools are used in safety-critical domains (e.g., spacecraft, aircraft, automotive, nuclear). The aims of the survey, therefore, were threefold: 1) to determine if code generation is primarily used as a tool for prototyping, including design exploration and simulation, or for fiight/production code; 2) to determine the verification issues with code generators relating, in particular, to qualification and certification in safety-critical domains; and 3) to determine perceived gaps in functionality of existing tools.

  15. MISSION: Mission and Safety Critical Support Environment. Executive overview

    NASA Technical Reports Server (NTRS)

    Mckay, Charles; Atkinson, Colin

    1992-01-01

    For mission and safety critical systems it is necessary to: improve definition, evolution and sustenance techniques; lower development and maintenance costs; support safe, timely and affordable system modifications; and support fault tolerance and survivability. The goal of the MISSION project is to lay the foundation for a new generation of integrated systems software providing a unified infrastructure for mission and safety critical applications and systems. This will involve the definition of a common, modular target architecture and a supporting infrastructure.

  16. A primer on criticality safety

    DOE PAGES

    Costa, David A.; Cournoyer, Michael E.; Merhege, James F.; ...

    2017-05-01

    Criticality is the state of a nuclear chain reacting medium when the chain reaction is just self-sustaining (or critical). Criticality is dependent on nine interrelated parameters. Moreover, we design criticality safety controls in order to constrain these parameters to minimize fissions and maximize neutron leakage and absorption in other materials, which makes criticality more difficult or impossible to achieve. We present the consequences of criticality accidents are discussed, the nine interrelated parameters that combine to affect criticality are described, and criticality safety controls used to minimize the likelihood of a criticality accident are presented.

  17. Safety Critical Mechanisms

    NASA Technical Reports Server (NTRS)

    Robertson, Brandan

    2008-01-01

    Spaceflight mechanisms have a reputation for being difficult to develop and operate successfully. This reputation is well earned. Many circumstances conspire to make this so: the environments in which the mechanisms are used are extremely severe, there is usually limited or no maintenance opportunity available during operation due to this environment, the environments are difficult to replicate accurately on the ground, the expense of the mechanism development makes it impractical to build and test many units for long periods of time before use, mechanisms tend to be highly specialized and not prone to interchangeability or off-the-shelf use, they can generate and store a lot of energy, and the nature of mechanisms themselves, as a combination of structures, electronics, etc. designed to accomplish specific dynamic performance, makes them very complex and subject to many unpredictable interactions of many types. In addition to their complexities, mechanism are often counted upon to provide critical vehicle functions that can result in catastrophic events should the functions not be performed. It is for this reason that mechanisms are frequently subjected to special scrutiny in safety processes. However, a failure tolerant approach, along with good design and development practices and detailed design reviews, can be developed to allow such notoriously troublesome mechanisms to be utilized confidently in safety-critical applications.

  18. An Approach for Validating Actinide and Fission Product Burnup Credit Criticality Safety Analyses: Criticality (k eff) Predictions

    DOE PAGES

    Scaglione, John M.; Mueller, Don E.; Wagner, John C.

    2014-12-01

    One of the most important remaining challenges associated with expanded implementation of burnup credit in the United States is the validation of depletion and criticality calculations used in the safety evaluation—in particular, the availability and use of applicable measured data to support validation, especially for fission products (FPs). Applicants and regulatory reviewers have been constrained by both a scarcity of data and a lack of clear technical basis or approach for use of the data. In this study, this paper describes a validation approach for commercial spent nuclear fuel (SNF) criticality safety (k eff) evaluations based on best-available data andmore » methods and applies the approach for representative SNF storage and transport configurations/conditions to demonstrate its usage and applicability, as well as to provide reference bias results. The criticality validation approach utilizes not only available laboratory critical experiment (LCE) data from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the French Haut Taux de Combustion program to support validation of the principal actinides but also calculated sensitivities, nuclear data uncertainties, and limited available FP LCE data to predict and verify individual biases for relevant minor actinides and FPs. The results demonstrate that (a) sufficient critical experiment data exist to adequately validate k eff calculations via conventional validation approaches for the primary actinides, (b) sensitivity-based critical experiment selection is more appropriate for generating accurate application model bias and uncertainty, and (c) calculated sensitivities and nuclear data uncertainties can be used for generating conservative estimates of bias for minor actinides and FPs. Results based on the SCALE 6.1 and the ENDF/B-VII.0 cross-section libraries indicate that a conservative estimate of the bias for the minor actinides and FPs is 1.5% of their worth within the

  19. Nuclear criticality safety: 5-day training course

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlesser, J.A.

    1992-11-01

    This compilation of notes is presented as a source reference for the criticality safety course. It represents the contributions of many people, particularly Tom McLaughlin, the course's primary instructor. At the completion of this training course, the attendee will: be able to define terms commonly used in nuclear criticality safety; be able to appreciate the fundamentals of nuclear criticality safety; be able to identify factors which affect nuclear criticality safety; be able to identify examples of criticality controls as used at Los Alamos; be able to identify examples of circumstances present during criticality accidents; be able to identify examples ofmore » computer codes used by the nuclear criticality safety specialist; be able to identify examples of safety consciousness required in nuclear criticality safety.« less

  20. An Approach for Validating Actinide and Fission Product Burnup Credit Criticality Safety Analyses--Criticality (keff) Predictions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scaglione, John M; Mueller, Don; Wagner, John C

    2011-01-01

    One of the most significant remaining challenges associated with expanded implementation of burnup credit in the United States is the validation of depletion and criticality calculations used in the safety evaluation - in particular, the availability and use of applicable measured data to support validation, especially for fission products. Applicants and regulatory reviewers have been constrained by both a scarcity of data and a lack of clear technical basis or approach for use of the data. U.S. Nuclear Regulatory Commission (NRC) staff have noted that the rationale for restricting their Interim Staff Guidance on burnup credit (ISG-8) to actinide-only ismore » based largely on the lack of clear, definitive experiments that can be used to estimate the bias and uncertainty for computational analyses associated with using burnup credit. To address the issue of validation, the NRC initiated a project with the Oak Ridge National Laboratory to (1) develop and establish a technically sound validation approach (both depletion and criticality) for commercial spent nuclear fuel (SNF) criticality safety evaluations based on best-available data and methods and (2) apply the approach for representative SNF storage and transport configurations/conditions to demonstrate its usage and applicability, as well as to provide reference bias results. The purpose of this paper is to describe the criticality (k{sub eff}) validation approach, and resulting observations and recommendations. Validation of the isotopic composition (depletion) calculations is addressed in a companion paper at this conference. For criticality validation, the approach is to utilize (1) available laboratory critical experiment (LCE) data from the International Handbook of Evaluated Criticality Safety Benchmark Experiments and the French Haut Taux de Combustion (HTC) program to support validation of the principal actinides and (2) calculated sensitivities, nuclear data uncertainties, and the limited available

  1. Automated Translation of Safety Critical Application Software Specifications into PLC Ladder Logic

    NASA Technical Reports Server (NTRS)

    Leucht, Kurt W.; Semmel, Glenn S.

    2008-01-01

    The numerous benefits of automatic application code generation are widely accepted within the software engineering community. A few of these benefits include raising the abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at the NASA Kennedy Space Center (KSC) recognized the need for PLC code generation while developing their new ground checkout and launch processing system. They developed a process and a prototype software tool that automatically translates a high-level representation or specification of safety critical application software into ladder logic that executes on a PLC. This process and tool are expected to increase the reliability of the PLC code over that which is written manually, and may even lower life-cycle costs and shorten the development schedule of the new control system at KSC. This paper examines the problem domain and discusses the process and software tool that were prototyped by the KSC software engineers.

  2. Cyber Security Threats to Safety-Critical, Space-Based Infrastructures

    NASA Astrophysics Data System (ADS)

    Johnson, C. W.; Atencia Yepez, A.

    2012-01-01

    Space-based systems play an important role within national critical infrastructures. They are being integrated into advanced air-traffic management applications, rail signalling systems, energy distribution software etc. Unfortunately, the end users of communications, location sensing and timing applications often fail to understand that these infrastructures are vulnerable to a wide range of security threats. The following pages focus on concerns associated with potential cyber-attacks. These are important because future attacks may invalidate many of the safety assumptions that support the provision of critical space-based services. These safety assumptions are based on standard forms of hazard analysis that ignore cyber-security considerations This is a significant limitation when, for instance, security attacks can simultaneously exploit multiple vulnerabilities in a manner that would never occur without a deliberate enemy seeking to damage space based systems and ground infrastructures. We address this concern through the development of a combined safety and security risk assessment methodology. The aim is to identify attack scenarios that justify the allocation of additional design resources so that safety barriers can be strengthened to increase our resilience against security threats.

  3. DOE standard 3009 - a reasoned, practical approach to integrating criticality safety into SARs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vessard, S.G.

    1995-12-31

    In the past there have been efforts by the U.S. Department of Energy (DOE) to provide guidance on those elements that should be included in a facility`s safety analysis report (SAR). In particular, there are two DOE Orders (5480.23, {open_quotes}Nuclear Safety Analysis Reports,{close_quotes} and 5480.24, {open_quotes}Nuclear Criticality Safety{close_quotes}), an interpretive guidance document (NE-70, Interpretive Guidance for DOE Order 5480.24, {open_quotes}Nuclear Criticality Safety{close_quotes}), and DOE Standard DOE-STD-3009-94 {open_quotes}Preparation Guide for U.S. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports.{close_quotes} Of these, the most practical and useful (pertaining to the application of criticality safety) is DOE-STD-3009-94. This paper is a reviewmore » of Chapters 3, 4, and 6 of this standard and how they provide very clear, helpful, and reasoned criticality safety guidance.« less

  4. Rethinking healthcare as a safety--critical industry.

    PubMed

    Lwears, Robert

    2012-01-01

    The discipline of ergonomics, or human factors engineering, has made substantial contributions to both the development of a science of safety, and to the improvement of safety in a wide variety of hazardous industries, including nuclear power, aviation, shipping, energy extraction and refining, military operations, and finance. It is notable that healthcare, which in most advanced societies is a substantial sector of the economy (eg, 15% of US gross domestic product) and has been associated with large volumes of potentially preventable morbidity and mortality, has heretofore not been viewed as a safety-critical industry. This paper proposes that improving safety performance in healthcare must involve a re-envisioning of healthcare itself as a safety-critical industry, but one with considerable differences from most engineered safety-critical systems. This has implications both for healthcare, and for conceptions of safety-critical industries.

  5. Nuclear Data Activities in Support of the DOE Nuclear Criticality Safety Program

    NASA Astrophysics Data System (ADS)

    Westfall, R. M.; McKnight, R. D.

    2005-05-01

    The DOE Nuclear Criticality Safety Program (NCSP) provides the technical infrastructure maintenance for those technologies applied in the evaluation and performance of safe fissionable-material operations in the DOE complex. These technologies include an Analytical Methods element for neutron transport as well as the development of sensitivity/uncertainty methods, the performance of Critical Experiments, evaluation and qualification of experiments as Benchmarks, and a comprehensive Nuclear Data program coordinated by the NCSP Nuclear Data Advisory Group (NDAG). The NDAG gathers and evaluates differential and integral nuclear data, identifies deficiencies, and recommends priorities on meeting DOE criticality safety needs to the NCSP Criticality Safety Support Group (CSSG). Then the NDAG identifies the required resources and unique capabilities for meeting these needs, not only for performing measurements but also for data evaluation with nuclear model codes as well as for data processing for criticality safety applications. The NDAG coordinates effort with the leadership of the National Nuclear Data Center, the Cross Section Evaluation Working Group (CSEWG), and the Working Party on International Evaluation Cooperation (WPEC) of the OECD/NEA Nuclear Science Committee. The overall objective is to expedite the issuance of new data and methods to the DOE criticality safety user. This paper describes these activities in detail, with examples based upon special studies being performed in support of criticality safety for a variety of DOE operations.

  6. Critical Characteristics of Radiation Detection System Components to be Dedicated for use in Safety Class and Safety Significant System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DAVIS, S.J.

    2000-05-25

    This document identifies critical characteristics of components to be dedicated for use in Safety Class (SC) or Safety Significant (SS) Systems, Structures, or Components (SSCs). This document identifies the requirements for the components of the common radiation area monitor alarm in the WESF pool cell. These are procured as Commercial Grade Items (CGI), with the qualification testing and formal dedication to be performed at the Waste Encapsulation Storage Facility (WESF), in safety class, safety significant systems. System modifications are to be performed in accordance with the instructions provided on ECN 658230. Components for this change are commercially available and interchangeablemore » with the existing alarm configuration This document focuses on the operational requirements for alarm, declaration of the safety classification, identification of critical characteristics, and interpretation of requirements for procurement. Critical characteristics are identified herein and must be verified, followed by formal dedication, prior to the components being used in safety related applications.« less

  7. Criticality Safety Evaluation for the TACS at DAF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Percher, C. M.; Heinrichs, D. P.

    2011-06-10

    Hands-on experimental training in the physical behavior of multiplying systems is one of ten key areas of training required for practitioners to become qualified in the discipline of criticality safety as identified in DOE-STD-1135-99, Guidance for Nuclear Criticality Safety Engineer Training and Qualification. This document is a criticality safety evaluation of the training activities and operations associated with HS-3201-P, Nuclear Criticality 4-Day Training Course (Practical). This course was designed to also address the training needs of nuclear criticality safety professionals under the auspices of the NNSA Nuclear Criticality Safety Program1. The hands-on, or laboratory, portion of the course will utilizemore » the Training Assembly for Criticality Safety (TACS) and will be conducted in the Device Assembly Facility (DAF) at the Nevada Nuclear Security Site (NNSS). The training activities will be conducted by Lawrence Livermore National Laboratory following the requirements of an Integrated Work Sheet (IWS) and associated Safety Plan. Students will be allowed to handle the fissile material under the supervision of an LLNL Certified Fissile Material Handler.« less

  8. The Department of Energy Nuclear Criticality Safety Program

    NASA Astrophysics Data System (ADS)

    Felty, James R.

    2005-05-01

    This paper broadly covers key events and activities from which the Department of Energy Nuclear Criticality Safety Program (NCSP) evolved. The NCSP maintains fundamental infrastructure that supports operational criticality safety programs. This infrastructure includes continued development and maintenance of key calculational tools, differential and integral data measurements, benchmark compilation, development of training resources, hands-on training, and web-based systems to enhance information preservation and dissemination. The NCSP was initiated in response to Defense Nuclear Facilities Safety Board Recommendation 97-2, Criticality Safety, and evolved from a predecessor program, the Nuclear Criticality Predictability Program, that was initiated in response to Defense Nuclear Facilities Safety Board Recommendation 93-2, The Need for Critical Experiment Capability. This paper also discusses the role Dr. Sol Pearlstein played in helping the Department of Energy lay the foundation for a robust and enduring criticality safety infrastructure.

  9. Implementation of COTs Hardware in Non-Critical Space Applications: A Brief Tutorial

    NASA Technical Reports Server (NTRS)

    Yoder, Geoffrey L.

    2004-01-01

    Approaches used for manned applications include limited items such as CD-players evaluated for safety to high criticality applications where the COTs hardware is evaluated on a case-by-case basis for the application and commensurate screening and qualification testing. COTS hardware is successfully implemented in both the International Space Station and Space Shuttle but requires evaluation and modifications for the application. Screening and qualification of COTs hardware used in critical applications may need to be more extensive and stringent than traditional military screening. Evaluation for: a) Suitability for the application; b) Safety; c) Reliability and maintainability; and d) Workmanship.

  10. Proceedings of the Nuclear Criticality Technology Safety Workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rene G. Sanchez

    1998-04-01

    This document contains summaries of most of the papers presented at the 1995 Nuclear Criticality Technology Safety Project (NCTSP) meeting, which was held May 16 and 17 at San Diego, Ca. The meeting was broken up into seven sessions, which covered the following topics: (1) Criticality Safety of Project Sapphire; (2) Relevant Experiments For Criticality Safety; (3) Interactions with the Former Soviet Union; (4) Misapplications and Limitations of Monte Carlo Methods Directed Toward Criticality Safety Analyses; (5) Monte Carlo Vulnerabilities of Execution and Interpretation; (6) Monte Carlo Vulnerabilities of Representation; and (7) Benchmark Comparisons.

  11. Critical Characteristics of Radiation Detection System Components to be Dedicated for use in Safety Class and Safety Significant System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DAVIS, S.J.

    2000-12-28

    This document identifies critical characteristics of components to be dedicated for use in Safety Significant (SS) Systems, Structures, or Components (SSCs). This document identifies the requirements for the components of the common, radiation area, monitor alarm in the WESF pool cell. These are procured as Commercial Grade Items (CGI), with the qualification testing and formal dedication to be performed at the Waste Encapsulation Storage Facility (WESF) for use in safety significant systems. System modifications are to be performed in accordance with the approved design. Components for this change are commercially available and interchangeable with the existing alarm configuration This documentmore » focuses on the operational requirements for alarm, declaration of the safety classification, identification of critical characteristics, and interpretation of requirements for procurement. Critical characteristics are identified herein and must be verified, followed by formal dedication, prior to the components being used in safety related applications.« less

  12. RICIS Symposium 1992: Mission and Safety Critical Systems Research and Applications

    NASA Technical Reports Server (NTRS)

    1992-01-01

    This conference deals with computer systems which control systems whose failure to operate correctly could produce the loss of life and or property, mission and safety critical systems. Topics covered are: the work of standards groups, computer systems design and architecture, software reliability, process control systems, knowledge based expert systems, and computer and telecommunication protocols.

  13. Planning the Unplanned Experiment: Assessing the Efficacy of Standards for Safety Critical Software

    NASA Technical Reports Server (NTRS)

    Graydon, Patrick J.; Holloway, C. Michael

    2015-01-01

    We need well-founded means of determining whether software is t for use in safety-critical applications. While software in industries such as aviation has an excellent safety record, the fact that software aws have contributed to deaths illustrates the need for justi ably high con dence in software. It is often argued that software is t for safety-critical use because it conforms to a standard for software in safety-critical systems. But little is known about whether such standards `work.' Reliance upon a standard without knowing whether it works is an experiment; without collecting data to assess the standard, this experiment is unplanned. This paper reports on a workshop intended to explore how standards could practicably be assessed. Planning the Unplanned Experiment: Assessing the Ecacy of Standards for Safety Critical Software (AESSCS) was held on 13 May 2014 in conjunction with the European Dependable Computing Conference (EDCC). We summarize and elaborate on the workshop's discussion of the topic, including both the presented positions and the dialogue that ensued.

  14. Nuclear Criticality Safety Data Book

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hollenbach, D. F.

    The objective of this document is to support the revision of criticality safety process studies (CSPSs) for the Uranium Processing Facility (UPF) at the Y-12 National Security Complex (Y-12). This design analysis and calculation (DAC) document contains development and justification for generic inputs typically used in Nuclear Criticality Safety (NCS) DACs to model both normal and abnormal conditions of processes at UPF to support CSPSs. This will provide consistency between NCS DACs and efficiency in preparation and review of DACs, as frequently used data are provided in one reference source.

  15. Evaluating Models of Human Performance: Safety-Critical Systems Applications

    NASA Technical Reports Server (NTRS)

    Feary, Michael S.

    2012-01-01

    This presentation is part of panel discussion on Evaluating Models of Human Performance. The purpose of this panel is to discuss the increasing use of models in the world today and specifically focus on how to describe and evaluate models of human performance. My presentation will focus on discussions of generating distributions of performance, and the evaluation of different strategies for humans performing tasks with mixed initiative (Human-Automation) systems. I will also discuss issues with how to provide Human Performance modeling data to support decisions on acceptability and tradeoffs in the design of safety critical systems. I will conclude with challenges for the future.

  16. Planning the Unplanned Experiment: Towards Assessing the Efficacy of Standards for Safety-Critical Software

    NASA Technical Reports Server (NTRS)

    Graydon, Patrick J.; Holloway, C. M.

    2015-01-01

    Safe use of software in safety-critical applications requires well-founded means of determining whether software is fit for such use. While software in industries such as aviation has a good safety record, little is known about whether standards for software in safety-critical applications 'work' (or even what that means). It is often (implicitly) argued that software is fit for safety-critical use because it conforms to an appropriate standard. Without knowing whether a standard works, such reliance is an experiment; without carefully collecting assessment data, that experiment is unplanned. To help plan the experiment, we organized a workshop to develop practical ideas for assessing software safety standards. In this paper, we relate and elaborate on the workshop discussion, which revealed subtle but important study design considerations and practical barriers to collecting appropriate historical data and recruiting appropriate experimental subjects. We discuss assessing standards as written and as applied, several candidate definitions for what it means for a standard to 'work,' and key assessment strategies and study techniques and the pros and cons of each. Finally, we conclude with thoughts about the kinds of research that will be required and how academia, industry, and regulators might collaborate to overcome the noted barriers.

  17. HSE's safety assessment principles for criticality safety.

    PubMed

    Simister, D N; Finnerty, M D; Warburton, S J; Thomas, E A; Macphail, M R

    2008-06-01

    The Health and Safety Executive (HSE) published its revised Safety Assessment Principles for Nuclear Facilities (SAPs) in December 2006. The SAPs are primarily intended for use by HSE's inspectors when judging the adequacy of safety cases for nuclear facilities. The revised SAPs relate to all aspects of safety in nuclear facilities including the technical discipline of criticality safety. The purpose of this paper is to set out for the benefit of a wider audience some of the thinking behind the final published words and to provide an insight into the development of UK regulatory guidance. The paper notes that it is HSE's intention that the Safety Assessment Principles should be viewed as a reflection of good practice in the context of interpreting primary legislation such as the requirements under site licence conditions for arrangements for producing an adequate safety case and for producing a suitable and sufficient risk assessment under the Ionising Radiations Regulations 1999 (SI1999/3232 www.opsi.gov.uk/si/si1999/uksi_19993232_en.pdf).

  18. Software Safety Risk in Legacy Safety-Critical Computer Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.; Baggs, Rhoda

    2007-01-01

    Safety Standards contain technical and process-oriented safety requirements. Technical requirements are those such as "must work" and "must not work" functions in the system. Process-Oriented requirements are software engineering and safety management process requirements. Address the system perspective and some cover just software in the system > NASA-STD-8719.13B Software Safety Standard is the current standard of interest. NASA programs/projects will have their own set of safety requirements derived from the standard. Safety Cases: a) Documented demonstration that a system complies with the specified safety requirements. b) Evidence is gathered on the integrity of the system and put forward as an argued case. [Gardener (ed.)] c) Problems occur when trying to meet safety standards, and thus make retrospective safety cases, in legacy safety-critical computer systems.

  19. Recognising safety critical events: can automatic video processing improve naturalistic data analyses?

    PubMed

    Dozza, Marco; González, Nieves Pañeda

    2013-11-01

    New trends in research on traffic accidents include Naturalistic Driving Studies (NDS). NDS are based on large scale data collection of driver, vehicle, and environment information in real world. NDS data sets have proven to be extremely valuable for the analysis of safety critical events such as crashes and near crashes. However, finding safety critical events in NDS data is often difficult and time consuming. Safety critical events are currently identified using kinematic triggers, for instance searching for deceleration below a certain threshold signifying harsh braking. Due to the low sensitivity and specificity of this filtering procedure, manual review of video data is currently necessary to decide whether the events identified by the triggers are actually safety critical. Such reviewing procedure is based on subjective decisions, is expensive and time consuming, and often tedious for the analysts. Furthermore, since NDS data is exponentially growing over time, this reviewing procedure may not be viable anymore in the very near future. This study tested the hypothesis that automatic processing of driver video information could increase the correct classification of safety critical events from kinematic triggers in naturalistic driving data. Review of about 400 video sequences recorded from the events, collected by 100 Volvo cars in the euroFOT project, suggested that drivers' individual reaction may be the key to recognize safety critical events. In fact, whether an event is safety critical or not often depends on the individual driver. A few algorithms, able to automatically classify driver reaction from video data, have been compared. The results presented in this paper show that the state of the art subjective review procedures to identify safety critical events from NDS can benefit from automated objective video processing. In addition, this paper discusses the major challenges in making such video analysis viable for future NDS and new potential

  20. Safety Criticality Standards Using the French CRISTAL Code Package: Application to the AREVA NP UO{sub 2} Fuel Fabrication Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doucet, M.; Durant Terrasson, L.; Mouton, J.

    2006-07-01

    Criticality safety evaluations implement requirements to proof of sufficient sub critical margins outside of the reactor environment for example in fuel fabrication plants. Basic criticality data (i.e., criticality standards) are used in the determination of sub critical margins for all processes involving plutonium or enriched uranium. There are several criticality international standards, e.g., ARH-600, which is one the US nuclear industry relies on. The French Nuclear Safety Authority (DGSNR and its advising body IRSN) has requested AREVA NP to review the criticality standards used for the evaluation of its Low Enriched Uranium fuel fabrication plants with CRISTAL V0, the recentlymore » updated French criticality evaluation package. Criticality safety is a concern for every phase of the fabrication process including UF{sub 6} cylinder storage, UF{sub 6}-UO{sub 2} conversion, powder storage, pelletizing, rod loading, assembly fabrication, and assembly transportation. Until 2003, the accepted criticality standards were based on the French CEA work performed in the late seventies with the APOLLO1 cell/assembly computer code. APOLLO1 is a spectral code, used for evaluating the basic characteristics of fuel assemblies for reactor physics applications, which has been enhanced to perform criticality safety calculations. Throughout the years, CRISTAL, starting with APOLLO1 and MORET 3 (a 3D Monte Carlo code), has been improved to account for the growth of its qualification database and for increasing user requirements. Today, CRISTAL V0 is an up-to-date computational tool incorporating a modern basic microscopic cross section set based on JEF2.2 and the comprehensive APOLLO2 and MORET 4 codes. APOLLO2 is well suited for criticality standards calculations as it includes a sophisticated self shielding approach, a P{sub ij} flux determination, and a 1D transport (S{sub n}) process. CRISTAL V0 is the result of more than five years of development work focusing on

  1. Criticality Safety Basics for INL FMHs and CSOs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    V. L. Putman

    2012-04-01

    Nuclear power is a valuable and efficient energy alternative in our energy-intensive society. However, material that can generate nuclear power has properties that require this material be handled with caution. If improperly handled, a criticality accident could result, which could severely harm workers. This document is a modular self-study guide about Criticality Safety Principles. This guide's purpose it to help you work safely in areas where fissionable nuclear materials may be present, avoiding the severe radiological and programmatic impacts of a criticality accident. It is designed to stress the fundamental physical concepts behind criticality controls and the importance of criticalitymore » safety when handling fissionable materials outside nuclear reactors. This study guide was developed for fissionable-material-handler and criticality-safety-officer candidates to use with related web-based course 00INL189, BEA Criticality Safety Principles, and to help prepare for the course exams. These individuals must understand basic information presented here. This guide may also be useful to other Idaho National Laboratory personnel who must know criticality safety basics to perform their assignments safely or to design critically safe equipment or operations. This guide also includes additional information that will not be included in 00INL189 tests. The additional information is in appendices and paragraphs with headings that begin with 'Did you know,' or with, 'Been there Done that'. Fissionable-material-handler and criticality-safety-officer candidates may review additional information at their own discretion. This guide is revised as needed to reflect program changes, user requests, and better information. Issued in 2006, Revision 0 established the basic text and integrated various programs from former contractors. Revision 1 incorporates operation and program changes implemented since 2006. It also incorporates suggestions, clarifications, and additional

  2. Nuclear criticality safety staff training and qualifications at Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monahan, S.P.; McLaughlin, T.P.

    1997-05-01

    Operations involving significant quantities of fissile material have been conducted at Los Alamos National Laboratory continuously since 1943. Until the advent of the Laboratory`s Nuclear Criticality Safety Committee (NCSC) in 1957, line management had sole responsibility for controlling criticality risks. From 1957 until 1961, the NCSC was the Laboratory body which promulgated policy guidance as well as some technical guidance for specific operations. In 1961 the Laboratory created the position of Nuclear Criticality Safety Office (in addition to the NCSC). In 1980, Laboratory management moved the Criticality Safety Officer (and one other LACEF staff member who, by that time, wasmore » also working nearly full-time on criticality safety issues) into the Health Division office. Later that same year the Criticality Safety Group, H-6 (at that time) was created within H-Division, and staffed by these two individuals. The training and education of these individuals in the art of criticality safety was almost entirely self-regulated, depending heavily on technical interactions between each other, as well as NCSC, LACEF, operations, other facility, and broader criticality safety community personnel. Although the Los Alamos criticality safety group has grown both in size and formality of operations since 1980, the basic philosophy that a criticality specialist must be developed through mentoring and self motivation remains the same. Formally, this philosophy has been captured in an internal policy, document ``Conduct of Business in the Nuclear Criticality Safety Group.`` There are no short cuts or substitutes in the development of a criticality safety specialist. A person must have a self-motivated personality, excellent communications skills, a thorough understanding of the principals of neutron physics, a safety-conscious and helpful attitude, a good perspective of real risk, as well as a detailed understanding of process operations and credible upsets.« less

  3. Additional nuclear criticality safety calculations for small-diameter containers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hone, M.J.

    This report documents additional criticality safety analysis calculations for small diameter containers, which were originally documented in Reference 1. The results in Reference 1 indicated that some of the small diameter containers did not meet the criteria established for criticality safety at the Portsmouth facility (K{sub eff} +2{sigma}<.95) when modeled under various contingency assumptions of reflection and moderation. The calculations performed in this report reexamine those cases which did not meet the criticality safety criteria. In some cases, unnecessary conservatism is removed, and in other cases mass or assay limits are established for use with the respective containers.

  4. Providing Nuclear Criticality Safety Analysis Education through Benchmark Experiment Evaluation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    John D. Bess; J. Blair Briggs; David W. Nigg

    2009-11-01

    One of the challenges that today's new workforce of nuclear criticality safety engineers face is the opportunity to provide assessment of nuclear systems and establish safety guidelines without having received significant experience or hands-on training prior to graduation. Participation in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and/or the International Reactor Physics Experiment Evaluation Project (IRPhEP) provides students and young professionals the opportunity to gain experience and enhance critical engineering skills.

  5. Commercial grade item (CGI) dedication of generators for nuclear safety related applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, R.K.; Hajos, L.G.

    1993-03-01

    The number of nuclear safety related equipment suppliers and the availability of spare and replacement parts designed specifically for nuclear safety related application are shrinking rapidly. These have made it necessary for utilities to apply commercial grade spare and replacement parts in nuclear safety related applications after implementing proper acceptance and dedication process to verify that such items conform with the requirements of their use in nuclear safety related application. The general guidelines for the commercial grade item (CGI) acceptance and dedication are provided in US Nuclear Regulatory Commission (NRC) Generic Letters and Electric Power Research Institute (EPRI) Report NP-5652,more » Guideline for the Utilization of Commercial Grade Items in Nuclear Safety Related Applications. This paper presents an application of these generic guidelines for procurement, acceptance, and dedication of a commercial grade generator for use as a standby generator at Salem Generating Station Units 1 and 2. The paper identifies the critical characteristics of the generator which once verified, will provide reasonable assurance that the generator will perform its intended safety function. The paper also delineates the method of verification of the critical characteristics through tests and provide acceptance criteria for the test results. The methodology presented in this paper may be used as specific guidelines for reliable and cost effective procurement and dedication of commercial grade generators for use as standby generators at nuclear power plants.« less

  6. Introduction to FPGA Devices and The Challenges for Critical Application - A User's Perspective

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Kenneth

    2015-01-01

    This presentation is an introduction to Field Programmable Gate Array (FPGA) devices and the challenges of critical application including: safety, reliability, availability, recoverability, and security.

  7. 48 CFR 209.270 - Aviation and ship critical safety items.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Aviation and ship critical safety items. 209.270 Section 209.270 Federal Acquisition Regulations System DEFENSE ACQUISITION... Requirements 209.270 Aviation and ship critical safety items. ...

  8. 48 CFR 209.270 - Aviation and ship critical safety items.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Aviation and ship critical safety items. 209.270 Section 209.270 Federal Acquisition Regulations System DEFENSE ACQUISITION... Requirements 209.270 Aviation and ship critical safety items. ...

  9. 48 CFR 209.270 - Aviation and ship critical safety items.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Aviation and ship critical safety items. 209.270 Section 209.270 Federal Acquisition Regulations System DEFENSE ACQUISITION... Requirements 209.270 Aviation and ship critical safety items. ...

  10. 48 CFR 209.270 - Aviation and ship critical safety items.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Aviation and ship critical safety items. 209.270 Section 209.270 Federal Acquisition Regulations System DEFENSE ACQUISITION... Requirements 209.270 Aviation and ship critical safety items. ...

  11. 48 CFR 209.270 - Aviation and ship critical safety items.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Requirements 209.270 Aviation and ship critical safety items. ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Aviation and ship critical safety items. 209.270 Section 209.270 Federal Acquisition Regulations System DEFENSE ACQUISITION...

  12. Product Engineering Class in the Software Safety Risk Taxonomy for Building Safety-Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice; Victor, Daniel

    2008-01-01

    When software safety requirements are imposed on legacy safety-critical systems, retrospective safety cases need to be formulated as part of recertifying the systems for further use and risks must be documented and managed to give confidence for reusing the systems. The SEJ Software Development Risk Taxonomy [4] focuses on general software development issues. It does not, however, cover all the safety risks. The Software Safety Risk Taxonomy [8] was developed which provides a construct for eliciting and categorizing software safety risks in a straightforward manner. In this paper, we present extended work on the taxonomy for safety that incorporates the additional issues inherent in the development and maintenance of safety-critical systems with software. An instrument called a Software Safety Risk Taxonomy Based Questionnaire (TBQ) is generated containing questions addressing each safety attribute in the Software Safety Risk Taxonomy. Software safety risks are surfaced using the new TBQ and then analyzed. In this paper we give the definitions for the specialized Product Engineering Class within the Software Safety Risk Taxonomy. At the end of the paper, we present the tool known as the 'Legacy Systems Risk Database Tool' that is used to collect and analyze the data required to show traceability to a particular safety standard

  13. Approach for validating actinide and fission product compositions for burnup credit criticality safety analyses

    DOE PAGES

    Radulescu, Georgeta; Gauld, Ian C.; Ilas, Germina; ...

    2014-11-01

    This paper describes a depletion code validation approach for criticality safety analysis using burnup credit for actinide and fission product nuclides in spent nuclear fuel (SNF) compositions. The technical basis for determining the uncertainties in the calculated nuclide concentrations is comparison of calculations to available measurements obtained from destructive radiochemical assay of SNF samples. Probability distributions developed for the uncertainties in the calculated nuclide concentrations were applied to the SNF compositions of a criticality safety analysis model by the use of a Monte Carlo uncertainty sampling method to determine bias and bias uncertainty in effective neutron multiplication factor. Application ofmore » the Monte Carlo uncertainty sampling approach is demonstrated for representative criticality safety analysis models of pressurized water reactor spent fuel pool storage racks and transportation packages using burnup-dependent nuclide concentrations calculated with SCALE 6.1 and the ENDF/B-VII nuclear data. Furthermore, the validation approach and results support a recent revision of the U.S. Nuclear Regulatory Commission Interim Staff Guidance 8.« less

  14. Tank waste remediation system nuclear criticality safety program management review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    BRADY RAAP, M.C.

    1999-06-24

    This document provides the results of an internal management review of the Tank Waste Remediation System (TWRS) criticality safety program, performed in advance of the DOE/RL assessment for closure of the TWRS Nuclear Criticality Safety Issue, March 1994. Resolution of the safety issue was identified as Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone M-40-12, due September 1999.

  15. GROWTH OF THE INTERNATIONAL CRITICALITY SAFETY AND REACTOR PHYSICS EXPERIMENT EVALUATION PROJECTS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Blair Briggs; John D. Bess; Jim Gulliford

    2011-09-01

    Since the International Conference on Nuclear Criticality Safety (ICNC) 2007, the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and the International Reactor Physics Experiment Evaluation Project (IRPhEP) have continued to expand their efforts and broaden their scope. Eighteen countries participated on the ICSBEP in 2007. Now, there are 20, with recent contributions from Sweden and Argentina. The IRPhEP has also expanded from eight contributing countries in 2007 to 16 in 2011. Since ICNC 2007, the contents of the 'International Handbook of Evaluated Criticality Safety Benchmark Experiments1' have increased from 442 evaluations (38000 pages), containing benchmark specifications for 3955 critical ormore » subcritical configurations to 516 evaluations (nearly 55000 pages), containing benchmark specifications for 4405 critical or subcritical configurations in the 2010 Edition of the ICSBEP Handbook. The contents of the Handbook have also increased from 21 to 24 criticality-alarm-placement/shielding configurations with multiple dose points for each, and from 20 to 200 configurations categorized as fundamental physics measurements relevant to criticality safety applications. Approximately 25 new evaluations and 150 additional configurations are expected to be added to the 2011 edition of the Handbook. Since ICNC 2007, the contents of the 'International Handbook of Evaluated Reactor Physics Benchmark Experiments2' have increased from 16 different experimental series that were performed at 12 different reactor facilities to 53 experimental series that were performed at 30 different reactor facilities in the 2011 edition of the Handbook. Considerable effort has also been made to improve the functionality of the searchable database, DICE (Database for the International Criticality Benchmark Evaluation Project) and verify the accuracy of the data contained therein. DICE will be discussed in separate papers at ICNC 2011. The status of the ICSBEP and

  16. Is Model-Based Development a Favorable Approach for Complex and Safety-Critical Computer Systems on Commercial Aircraft?

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo

    2014-01-01

    A system is safety-critical if its failure can endanger human life or cause significant damage to property or the environment. State-of-the-art computer systems on commercial aircraft are highly complex, software-intensive, functionally integrated, and network-centric systems of systems. Ensuring that such systems are safe and comply with existing safety regulations is costly and time-consuming as the level of rigor in the development process, especially the validation and verification activities, is determined by considerations of system complexity and safety criticality. A significant degree of care and deep insight into the operational principles of these systems is required to ensure adequate coverage of all design implications relevant to system safety. Model-based development methodologies, methods, tools, and techniques facilitate collaboration and enable the use of common design artifacts among groups dealing with different aspects of the development of a system. This paper examines the application of model-based development to complex and safety-critical aircraft computer systems. Benefits and detriments are identified and an overall assessment of the approach is given.

  17. Criticality Safety Evaluation of the LLNL Inherently Safe Subcritical Assembly (ISSA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Percher, Catherine

    2012-06-19

    The LLNL Nuclear Criticality Safety Division has developed a training center to illustrate criticality safety and reactor physics concepts through hands-on experimental training. The experimental assembly, the Inherently Safe Subcritical Assembly (ISSA), uses surplus highly enriched research reactor fuel configured in a water tank. The training activities will be conducted by LLNL following the requirements of an Integration Work Sheet (IWS) and associated Safety Plan. Students will be allowed to handle the fissile material under the supervision of LLNL instructors. This report provides the technical criticality safety basis for instructional operations with the ISSA experimental assembly.

  18. Overview of Risk Mitigation for Safety-Critical Computer-Based Systems

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo

    2015-01-01

    This report presents a high-level overview of a general strategy to mitigate the risks from threats to safety-critical computer-based systems. In this context, a safety threat is a process or phenomenon that can cause operational safety hazards in the form of computational system failures. This report is intended to provide insight into the safety-risk mitigation problem and the characteristics of potential solutions. The limitations of the general risk mitigation strategy are discussed and some options to overcome these limitations are provided. This work is part of an ongoing effort to enable well-founded assurance of safety-related properties of complex safety-critical computer-based aircraft systems by developing an effective capability to model and reason about the safety implications of system requirements and design.

  19. Review of Estelle and LOTOS with respect to critical computer applications

    NASA Technical Reports Server (NTRS)

    Bown, Rodney L.

    1991-01-01

    Man rated NASA space vehicles seem to represent a set of ultimate critical computer applications. These applications require a high degree of security, integrity, and safety. A variety of formal and/or precise modeling techniques are becoming available for the designer of critical systems. The design phase of the software engineering life cycle includes the modification of non-development components. A review of the Estelle and LOTOS formal description languages is presented. Details of the languages and a set of references are provided. The languages were used to formally describe some of the Open System Interconnect (OSI) protocols.

  20. 48 CFR 252.209-7010 - Critical Safety Items.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... personal injury or loss of life; or (iii) An uncommanded engine shutdown that jeopardizes safety. Design... personal injury or loss of life. (b) Identification of critical safety items. One or more of the items... control activity: (Insert additional lines as necessary) (c) Heightened quality assurance surveillance...

  1. 48 CFR 252.209-7010 - Critical Safety Items.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... personal injury or loss of life; or (iii) An uncommanded engine shutdown that jeopardizes safety. Design... personal injury or loss of life. (b) Identification of critical safety items. One or more of the items... control activity: (Insert additional lines as necessary) (c) Heightened quality assurance surveillance...

  2. 48 CFR 252.209-7010 - Critical Safety Items.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... personal injury or loss of life; or (iii) An uncommanded engine shutdown that jeopardizes safety. Design... personal injury or loss of life. (b) Identification of critical safety items. One or more of the items... control activity: (Insert additional lines as necessary) (c) Heightened quality assurance surveillance...

  3. 48 CFR 252.209-7010 - Critical Safety Items.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... personal injury or loss of life; or (iii) An uncommanded engine shutdown that jeopardizes safety. Design... personal injury or loss of life. (b) Identification of critical safety items. One or more of the items... control activity: (Insert additional lines as necessary) (c) Heightened quality assurance surveillance...

  4. 76 FR 52138 - Defense Federal Acquisition Regulation Supplement; Identification of Critical Safety Items (DFARS...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ...; or (iii) An uncommanded engine shutdown that jeopardizes safety. Design control activity. (i) With... aviation critical safety item is to be used; and (ii) With respect to a ship critical safety item, means...-AG92 Defense Federal Acquisition Regulation Supplement; Identification of Critical Safety Items (DFARS...

  5. Safety assessment in plant layout design using indexing approach: implementing inherent safety perspective. Part 1 - guideword applicability and method description.

    PubMed

    Tugnoli, Alessandro; Khan, Faisal; Amyotte, Paul; Cozzani, Valerio

    2008-12-15

    Layout planning plays a key role in the inherent safety performance of process plants since this design feature controls the possibility of accidental chain-events and the magnitude of possible consequences. A lack of suitable methods to promote the effective implementation of inherent safety in layout design calls for the development of new techniques and methods. In the present paper, a safety assessment approach suitable for layout design in the critical early phase is proposed. The concept of inherent safety is implemented within this safety assessment; the approach is based on an integrated assessment of inherent safety guideword applicability within the constraints typically present in layout design. Application of these guidewords is evaluated along with unit hazards and control devices to quantitatively map the safety performance of different layout options. Moreover, the economic aspects related to safety and inherent safety are evaluated by the method. Specific sub-indices are developed within the integrated safety assessment system to analyze and quantify the hazard related to domino effects. The proposed approach is quick in application, auditable and shares a common framework applicable in other phases of the design lifecycle (e.g. process design). The present work is divided in two parts: Part 1 (current paper) presents the application of inherent safety guidelines in layout design and the index method for safety assessment; Part 2 (accompanying paper) describes the domino hazard sub-index and demonstrates the proposed approach with a case study, thus evidencing the introduction of inherent safety features in layout design.

  6. Review of battery powered embedded systems design for mission-critical low-power applications

    NASA Astrophysics Data System (ADS)

    Malewski, Matthew; Cowell, David M. J.; Freear, Steven

    2018-06-01

    The applications and uses of embedded systems is increasingly pervasive. Mission and safety critical systems relying on embedded systems pose specific challenges. Embedded systems is a multi-disciplinary domain, involving both hardware and software. Systems need to be designed in a holistic manner so that they are able to provide the desired reliability and minimise unnecessary complexity. The large problem landscape means that there is no one solution that fits all applications of embedded systems. With the primary focus of these mission and safety critical systems being functionality and reliability, there can be conflicts with business needs, and this can introduce pressures to reduce cost at the expense of reliability and functionality. This paper examines the challenges faced by battery powered systems, and then explores at more general problems, and several real-world embedded systems.

  7. Investigation of criticality safety control infraction data at a nuclear facility

    DOE PAGES

    Cournoyer, Michael E.; Merhege, James F.; Costa, David A.; ...

    2014-10-27

    Chemical and metallurgical operations involving plutonium and other nuclear materials account for most activities performed at the LANL's Plutonium Facility (PF-4). The presence of large quantities of fissile materials in numerous forms at PF-4 makes it necessary to maintain an active criticality safety program. The LANL Nuclear Criticality Safety (NCS) Program provides guidance to enable efficient operations while ensuring prevention of criticality accidents in the handling, storing, processing and transportation of fissionable material at PF-4. In order to achieve and sustain lower criticality safety control infraction (CSCI) rates, PF-4 operations are continuously improved, through the use of Lean Manufacturing andmore » Six Sigma (LSS) business practices. Employing LSS, statistically significant variations (trends) can be identified in PF-4 CSCI reports. In this study, trends have been identified in the NCS Program using the NCS Database. An output metric has been developed that measures ADPSM Management progress toward meeting its NCS objectives and goals. Using a Pareto Chart, the primary CSCI attributes have been determined in order of those requiring the most management support. Data generated from analysis of CSCI data help identify and reduce number of corresponding attributes. In-field monitoring of CSCI's contribute to an organization's scientific and technological excellence by providing information that can be used to improve criticality safety operation safety. This increases technical knowledge and augments operational safety.« less

  8. Critical safety assurance factors for manned spacecraft - A fire safety perspective

    NASA Technical Reports Server (NTRS)

    Rodney, George A.

    1990-01-01

    Safety assurance factors for manned spacecraft are discussed with a focus on the Space Station Freedom. A hazard scenario is provided to demonstrate a process commonly used by safety engineers and other analysts to identify onboard safety risks. Fire strategies are described, including a review of fire extinguishing agents being considered for the Space Station. Lessons learned about fire safety technology in other areas are also noted. NASA and industry research on fire safety applications is discussed. NASA's approach to ensuring safety for manned spacecraft is addressed in the context of its multidiscipline program.

  9. Lecture Notes on Criticality Safety Validation Using MCNP & Whisper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Forrest B.; Rising, Michael Evan; Alwin, Jennifer Louise

    Training classes for nuclear criticality safety, MCNP documentation. The need for, and problems surrounding, validation of computer codes and data area considered first. Then some background for MCNP & Whisper is given--best practices for Monte Carlo criticality calculations, neutron spectra, S(α,β) thermal neutron scattering data, nuclear data sensitivities, covariance data, and correlation coefficients. Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the Monte Carlo radiation transport package MCNP. Whisper's methodology (benchmark selection – C k's, weights; extreme value theory – bias, bias uncertainty; MOS for nuclear data uncertainty – GLLS) and usagemore » are discussed.« less

  10. Commercial grade item (CGI) dedication of MDR relays for nuclear safety related applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, R.K.; Julka, A.; Modi, G.

    1994-08-01

    MDR relays manufactured by Potter and Brumfield (P and B) have been used in various safety related applications in commercial nuclear power plants. These include emergency safety features (ESF) actuation systems, emergency core cooling systems (ECCS) actuation, and reactor protection systems. The MDR relays manufactured prior to May 1990 showed signs of generic failure due to corrosion and outgassing of coil varnish. P and B has made design changes to correct these problems in relays manufactured after May 1990. However, P and B does not manufacture the relays under any 10CFR50 Appendix B quality assurance (QA) program. They manufacture themore » relays under their commercial QA program and supply these as commercial grade items. This necessitates CGI Dedication of these relays for use in nuclear-safety-related applications. This paper presents a CGI dedication program that has been used to dedicate the MDR relays manufactured after May 1990. The program is in compliance with current Nuclear Regulatory Commission (NRC) and Electric Power Research Institute (EPRI) guidelines and applicable industry standards; it specifies the critical characteristics of the relays, provides the tests and analysis required to verify the critical characteristics, the acceptance criteria for the test results, performs source verification to qualify P and B for its control of the critical characteristics, and provides documentation. The program provides reasonable assurance that the new MDR relays will perform their intended safety functions.« less

  11. 49 CFR 229.309 - Safety-critical changes and failures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Safety-critical changes and failures. 229.309 Section 229.309 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Locomotive Electronics § 229...

  12. 49 CFR 229.309 - Safety-critical changes and failures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Safety-critical changes and failures. 229.309 Section 229.309 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Locomotive Electronics § 229...

  13. 49 CFR 229.309 - Safety-critical changes and failures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Safety-critical changes and failures. 229.309 Section 229.309 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Locomotive Electronics § 229...

  14. Cultural safety and the challenges of translating critically oriented knowledge in practice.

    PubMed

    Browne, Annette J; Varcoe, Colleen; Smye, Victoria; Reimer-Kirkham, Sheryl; Lynam, M Judith; Wong, Sabrina

    2009-07-01

    Cultural safety is a relatively new concept that has emerged in the New Zealand nursing context and is being taken up in various ways in Canadian health care discourses. Our research team has been exploring the relevance of cultural safety in the Canadian context, most recently in relation to a knowledge-translation study conducted with nurses practising in a large tertiary hospital. We were drawn to using cultural safety because we conceptualized it as being compatible with critical theoretical perspectives that foster a focus on power imbalances and inequitable social relationships in health care; the interrelated problems of culturalism and racialization; and a commitment to social justice as central to the social mandate of nursing. Engaging in this knowledge-translation study has provided new perspectives on the complexities, ambiguities and tensions that need to be considered when using the concept of cultural safety to draw attention to racialization, culturalism, and health and health care inequities. The philosophic analysis discussed in this paper represents an epistemological grounding for the concept of cultural safety that links directly to particular moral ends with social justice implications. Although cultural safety is a concept that we have firmly positioned within the paradigm of critical inquiry, ambiguities associated with the notions of 'culture', 'safety', and 'cultural safety' need to be anticipated and addressed if they are to be effectively used to draw attention to critical social justice issues in practice settings. Using cultural safety in practice settings to draw attention to and prompt critical reflection on politicized knowledge, therefore, brings an added layer of complexity. To address these complexities, we propose that what may be required to effectively use cultural safety in the knowledge-translation process is a 'social justice curriculum for practice' that would foster a philosophical stance of critical inquiry at both the

  15. Parametric Criticality Safety Calculations for Arrays of TRU Waste Containers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gough, Sean T.

    The Nuclear Criticality Safety Division (NCSD) has performed criticality safety calculations for finite and infinite arrays of transuranic (TRU) waste containers. The results of these analyses may be applied in any technical area onsite (e.g., TA-54, TA-55, etc.), as long as the assumptions herein are met. These calculations are designed to update the existing reference calculations for waste arrays documented in Reference 1, in order to meet current guidance on calculational methodology.

  16. University education and nuclear criticality safety professionals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, R.E.; Stachowiak, R.V.; Knief, R.A.

    1996-12-31

    The problem of developing a productive criticality safety specialist at a nuclear fuel facility has long been with us. The normal practice is to hire a recent undergraduate or graduate degree recipient and invest at least a decade in on-the-job training. In the early 1980s, the U.S. Department of Energy (DOE) developed a model intern program in an attempt to speed up the process. The program involved working at assigned projects for extended periods at a working critical mass laboratory, a methods development group, and a fuel cycle facility. This never gained support as it involved extended time away frommore » the job. At the Rocky Flats Environmental Technology Site, the training method is currently the traditional one involving extensive experience. The flaw is that the criticality safety staff turnover has been such that few individuals continue for the decade some consider necessary for maturity in the discipline. To maintain quality evaluations and controls as well as interpretation decisions, extensive group review is used. This has proved costly to the site and professionally unsatisfying to the current staff. The site contractor has proposed a training program to remedy the basic problem.« less

  17. 9 CFR 381.303 - Critical factors and the application of the process schedule.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION POULTRY PRODUCTS INSPECTION REGULATIONS... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Critical factors and the application of the process schedule. 381.303 Section 381.303 Animals and Animal Products FOOD SAFETY AND...

  18. Use of Unified Modeling Language (UML) in Model-Based Development (MBD) For Safety-Critical Applications

    DTIC Science & Technology

    2014-12-01

    appears that UML is becoming the de facto MBD language. OMG® states the following on the MDA® FAQ page: “Although not formally required [for MBD], UML...a known limitation [42], so UML users should plan accordingly, especially for safety-critical programs. For example, “models are not used to...description of the MBD tool chain can be produced. That description could be resident in a Plan for Software Aspects of Certification (PSAC) or Software

  19. Analyzing Software Requirements Errors in Safety-Critical, Embedded Systems

    NASA Technical Reports Server (NTRS)

    Lutz, Robyn R.

    1993-01-01

    This paper analyzes the root causes of safety-related software errors in safety-critical, embedded systems. The results show that software errors identified as potentially hazardous to the system tend to be produced by different error mechanisms than non- safety-related software errors. Safety-related software errors are shown to arise most commonly from (1) discrepancies between the documented requirements specifications and the requirements needed for correct functioning of the system and (2) misunderstandings of the software's interface with the rest of the system. The paper uses these results to identify methods by which requirements errors can be prevented. The goal is to reduce safety-related software errors and to enhance the safety of complex, embedded systems.

  20. Safety impacts of bicycle infrastructure: A critical review.

    PubMed

    DiGioia, Jonathan; Watkins, Kari Edison; Xu, Yanzhi; Rodgers, Michael; Guensler, Randall

    2017-06-01

    This paper takes a critical look at the present state of bicycle infrastructure treatment safety research, highlighting data needs. Safety literature relating to 22 bicycle treatments is examined, including findings, study methodologies, and data sources used in the studies. Some preliminary conclusions related to research efficacy are drawn from the available data and findings in the research. While the current body of bicycle safety literature points toward some defensible conclusions regarding the safety and effectiveness of certain bicycle treatments, such as bike lanes and removal of on-street parking, the vast majority treatments are still in need of rigorous research. Fundamental questions arise regarding appropriate exposure measures, crash measures, and crash data sources. This research will aid transportation departments with regard to decisions about bicycle infrastructure and guide future research efforts toward understanding safety impacts of bicycle infrastructure. Copyright © 2017 Elsevier Ltd and National Safety Council. All rights reserved.

  1. Sensitivity-Uncertainty Based Nuclear Criticality Safety Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Forrest B.

    2016-09-20

    These are slides from a seminar given to the University of Mexico Nuclear Engineering Department. Whisper is a statistical analysis package developed to support nuclear criticality safety validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit for the application. Whisper and its associated benchmark files are developed and maintained as part of MCNP6, and will be distributed with all future releases of MCNP6. Although sensitivity-uncertainty methods for NCS validation have been under development for 20 years, continuous-energy Monte Carlo codes such asmore » MCNP could not determine the required adjoint-weighted tallies for sensitivity profiles. The recent introduction of the iterated fission probability method into MCNP led to the rapid development of sensitivity analysis capabilities for MCNP6 and the development of Whisper. Sensitivity-uncertainty based methods represent the future for NCS validation – making full use of today’s computer power to codify past approaches based largely on expert judgment. Validation results are defensible, auditable, and repeatable as needed with different assumptions and process models. The new methods can supplement, support, and extend traditional validation approaches.« less

  2. Taking ownership of safety. What are the active ingredients of safety coaching and how do they impact safety outcomes in critical offshore working environments?

    PubMed

    Krauesslar, Victoria; Avery, Rachel E; Passmore, Jonathan

    2015-01-01

    Safety coaching interventions have become a common feature in the safety critical offshore working environments of the North Sea. Whilst the beneficial impact of coaching as an organizational tool has been evidenced, there remains a question specifically over the use of safety coaching and its impact on behavioural change and producing safe working practices. A series of 24 semi-structured interviews were conducted with three groups of experts in the offshore industry: safety coaches, offshore managers and HSE directors. Using a thematic analysis approach, several significant themes were identified across the three expert groups including connecting with and creating safety ownership in the individual, personal significance and humanisation, ingraining safety and assessing and measuring a safety coach's competence. Results suggest clear utility of safety coaching when applied by safety coaches with appropriate coach training and understanding of safety issues in an offshore environment. The current work has found that the use of safety coaching in the safety critical offshore oil and gas industry is a powerful tool in managing and promoting a culture of safety and care.

  3. Natural Language Interface for Safety Certification of Safety-Critical Software

    NASA Technical Reports Server (NTRS)

    Denney, Ewen; Fischer, Bernd

    2011-01-01

    Model-based design and automated code generation are being used increasingly at NASA. The trend is to move beyond simulation and prototyping to actual flight code, particularly in the guidance, navigation, and control domain. However, there are substantial obstacles to more widespread adoption of code generators in such safety-critical domains. Since code generators are typically not qualified, there is no guarantee that their output is correct, and consequently the generated code still needs to be fully tested and certified. The AutoCert generator plug-in supports the certification of automatically generated code by formally verifying that the generated code is free of different safety violations, by constructing an independently verifiable certificate, and by explaining its analysis in a textual form suitable for code reviews.

  4. Application of SAE ARP4754A to Flight Critical Systems

    NASA Technical Reports Server (NTRS)

    Peterson, Eric M.

    2015-01-01

    This report documents applications of ARP4754A to the development of modern computer-based (i.e., digital electronics, software and network-based) aircraft systems. This study is to offer insight and provide educational value relative to the guidelines in ARP4754A and provide an assessment of the current state-of-the- practice within industry and regulatory bodies relative to development assurance for complex and safety-critical computer-based aircraft systems.

  5. Criticality Safety Evaluation for Small Sample Preparation and Non-Destructive Assay (NDA) Operations in Wing 7 Basement of the CMR Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunkle, Paige Elizabeth; Zhang, Ning

    Nuclear Criticality Safety (NCS) has reviewed the fissionable material small sample preparation and NDA operations in Wing 7 Basement of the CMR Facility. This is a Level-1 evaluation conducted in accordance with NCS-AP-004 [Reference 1], formerly NCS-GUIDE-01, and the guidance set forth on use of the Standard Criticality Safety Requirements (SCSRs) [Reference 2]. As stated in Reference 2, the criticality safety evaluation consists of both the SCSR CSED and the SCSR Application CSED. The SCSR CSED is a Level-3 CSED [Reference 3]. This Level-1 CSED is the SCSR Application CSED. This SCSR Application (Level-1) evaluation does not derive controls, itmore » simply applies controls derived from the SCSR CSED (Level-3) for the application of operations conducted here. The controls derived in the SCSR CSED (Level-3) were evaluated via the process described in Section 6.6.5 of SD-130 (also reproduced in Section 4.3.5 of NCS-AP-004 [Reference 1]) and were determined to not meet the requirements for consideration of elevation into the safety basis documentation for CMR. According to the guidance set forth on use of the SCSRs [Reference 2], the SCSR CSED (Level-3) is also applicable to the CMR Facility because the process and the normal and credible abnormal conditions in question are bounded by those that are described in the SCSR CSED. The controls derived in the SCSR CSED include allowances for solid materials and solution operations. Based on the operations conducted at this location, there are less-than-accountable (LTA) amounts of 233U. Based on the evaluation documented herein, the normal and credible abnormal conditions that might arise during the execution of this process will remain subcritical with the following recommended controls.« less

  6. Agile Methods for Open Source Safety-Critical Software.

    PubMed

    Gary, Kevin; Enquobahrie, Andinet; Ibanez, Luis; Cheng, Patrick; Yaniv, Ziv; Cleary, Kevin; Kokoori, Shylaja; Muffih, Benjamin; Heidenreich, John

    2011-08-01

    The introduction of software technology in a life-dependent environment requires the development team to execute a process that ensures a high level of software reliability and correctness. Despite their popularity, agile methods are generally assumed to be inappropriate as a process family in these environments due to their lack of emphasis on documentation, traceability, and other formal techniques. Agile methods, notably Scrum, favor empirical process control, or small constant adjustments in a tight feedback loop. This paper challenges the assumption that agile methods are inappropriate for safety-critical software development. Agile methods are flexible enough to encourage the rightamount of ceremony; therefore if safety-critical systems require greater emphasis on activities like formal specification and requirements management, then an agile process will include these as necessary activities. Furthermore, agile methods focus more on continuous process management and code-level quality than classic software engineering process models. We present our experiences on the image-guided surgical toolkit (IGSTK) project as a backdrop. IGSTK is an open source software project employing agile practices since 2004. We started with the assumption that a lighter process is better, focused on evolving code, and only adding process elements as the need arose. IGSTK has been adopted by teaching hospitals and research labs, and used for clinical trials. Agile methods have matured since the academic community suggested they are not suitable for safety-critical systems almost a decade ago, we present our experiences as a case study for renewing the discussion.

  7. Agile Methods for Open Source Safety-Critical Software

    PubMed Central

    Enquobahrie, Andinet; Ibanez, Luis; Cheng, Patrick; Yaniv, Ziv; Cleary, Kevin; Kokoori, Shylaja; Muffih, Benjamin; Heidenreich, John

    2011-01-01

    The introduction of software technology in a life-dependent environment requires the development team to execute a process that ensures a high level of software reliability and correctness. Despite their popularity, agile methods are generally assumed to be inappropriate as a process family in these environments due to their lack of emphasis on documentation, traceability, and other formal techniques. Agile methods, notably Scrum, favor empirical process control, or small constant adjustments in a tight feedback loop. This paper challenges the assumption that agile methods are inappropriate for safety-critical software development. Agile methods are flexible enough to encourage the right amount of ceremony; therefore if safety-critical systems require greater emphasis on activities like formal specification and requirements management, then an agile process will include these as necessary activities. Furthermore, agile methods focus more on continuous process management and code-level quality than classic software engineering process models. We present our experiences on the image-guided surgical toolkit (IGSTK) project as a backdrop. IGSTK is an open source software project employing agile practices since 2004. We started with the assumption that a lighter process is better, focused on evolving code, and only adding process elements as the need arose. IGSTK has been adopted by teaching hospitals and research labs, and used for clinical trials. Agile methods have matured since the academic community suggested they are not suitable for safety-critical systems almost a decade ago, we present our experiences as a case study for renewing the discussion. PMID:21799545

  8. Commonalities and Differences in Functional Safety Systems Between ISS Payloads and Industrial Applications

    NASA Astrophysics Data System (ADS)

    Malyshev, Mikhail; Kreimer, Johannes

    2013-09-01

    Safety analyses for electrical, electronic and/or programmable electronic (E/E/EP) safety-related systems used in payload applications on-board the International Space Station (ISS) are often based on failure modes, effects and criticality analysis (FMECA). For industrial applications of E/E/EP safety-related systems, comparable strategies exist and are defined in the IEC-61508 standard. This standard defines some quantitative criteria based on potential failure modes (for example, Safe Failure Fraction). These criteria can be calculated for an E/E/EP system or components to assess their compliance to requirements of a particular Safety Integrity Level (SIL). The standard defines several SILs depending on how much risk has to be mitigated by a safety-critical system. When a FMECA is available for an ISS payload or its subsystem, it may be possible to calculate the same or similar parameters as defined in the 61508 standard. One example of a payload that has a dedicated functional safety subsystem is the Electromagnetic Levitator (EML). This payload for the ISS is planned to be operated on-board starting 2014. The EML is a high-temperature materials processing facility. The dedicated subsystem "Hazard Control Electronics" (HCE) is implemented to ensure compliance to failure tolerance in limiting samples processing parameters to maintain generation of the potentially toxic by-products to safe limits in line with the requirements applied to the payloads by the ISS Program. The objective of this paper is to assess the implementation of the HCE in the EML against criteria for functional safety systems in the IEC-61508 standard and to evaluate commonalities and differences with respect to safety requirements levied on ISS Payloads. An attempt is made to assess a possibility of using commercially available components and systems certified for compliance to industrial functional safety standards in ISS payloads.

  9. NASA's Software Safety Standard

    NASA Technical Reports Server (NTRS)

    Ramsay, Christopher M.

    2005-01-01

    NASA (National Aeronautics and Space Administration) relies more and more on software to control, monitor, and verify its safety critical systems, facilities and operations. Since the 1960's there has hardly been a spacecraft (manned or unmanned) launched that did not have a computer on board that provided vital command and control services. Despite this growing dependence on software control and monitoring, there has been no consistent application of software safety practices and methodology to NASA's projects with safety critical software. Led by the NASA Headquarters Office of Safety and Mission Assurance, the NASA Software Safety Standard (STD-18l9.13B) has recently undergone a significant update in an attempt to provide that consistency. This paper will discuss the key features of the new NASA Software Safety Standard. It will start with a brief history of the use and development of software in safety critical applications at NASA. It will then give a brief overview of the NASA Software Working Group and the approach it took to revise the software engineering process across the Agency.

  10. Covariance Applications in Criticality Safety, Light Water Reactor Analysis, and Spent Fuel Characterization

    DOE PAGES

    Williams, M. L.; Wiarda, D.; Ilas, G.; ...

    2014-06-15

    Recently, we processed a new covariance data library based on ENDF/B-VII.1 for the SCALE nuclear analysis code system. The multigroup covariance data are discussed here, along with testing and application results for critical benchmark experiments. Moreover, the cross section covariance library, along with covariances for fission product yields and decay data, is used to compute uncertainties in the decay heat produced by a burned reactor fuel assembly.

  11. Critical issues in sensor science to aid food and water safety.

    PubMed

    Farahi, R H; Passian, A; Tetard, L; Thundat, T

    2012-06-26

    The stability of food and water supplies is widely recognized as a global issue of fundamental importance. Sensor development for food and water safety by nonconventional assays continues to overcome technological challenges. The delicate balance between attaining adequate limits of detection, chemical fingerprinting of the target species, dealing with the complex food matrix, and operating in difficult environments are still the focus of current efforts. While the traditional pursuit of robust recognition methods remains important, emerging engineered nanomaterials and nanotechnology promise better sensor performance but also bring about new challenges. Both advanced receptor-based sensors and emerging non-receptor-based physical sensors are evaluated for their critical challenges toward out-of-laboratory applications.

  12. Submersion criticality safety of tungsten-rhenium urania cermet fuel for space propulsion and power applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A.E. Craft; R. C. O'Brien; S. D. Howe

    Nuclear thermal rockets are the preferred propulsion technology for a manned mission to Mars, and tungsten–uranium oxide cermet fuels could provide significant performance and cost advantages for nuclear thermal rockets. A nuclear reactor intended for use in space must remain subcritical before and during launch, and must remain subcritical in launch abort scenarios where the reactor falls back to Earth and becomes submerged in terrestrial materials (including seawater, wet sand, or dry sand). Submersion increases reflection of neutrons and also thermalizes the neutron spectrum, which typically increases the reactivity of the core. This effect is typically very significant for compact,more » fast-spectrum reactors. This paper provides a submersion criticality safety analysis for a representative tungsten/uranium oxide fueled reactor with a range of fuel compositions. Each submersion case considers both the rhenium content in the matrix alloy and the uranium oxide volume fraction in the cermet. The inclusion of rhenium significantly improves the submersion criticality safety of the reactor. While increased uranium oxide content increases the reactivity of the core, it does not significantly affect the submersion behavior of the reactor. There is no significant difference in submersion behavior between reactors with rhenium distributed within the cermet matrix and reactors with a rhenium clad in the coolant channels. The combination of the flooding of the coolant channels in submersion scenarios and the presence of a significant amount of spectral shift absorbers (i.e. high rhenium concentration) further decreases reactivity for short reactor cores compared to longer cores.« less

  13. Connected vehicle applications : safety.

    DOT National Transportation Integrated Search

    2016-01-01

    Connected vehicle safety applications are designed to increase situational awareness : and reduce or eliminate crashes through vehicle-to-infrastructure, vehicle-to-vehicle, : and vehicle-to-pedestrian data transmissions. Applications support advisor...

  14. Connected vehicle applications : safety.

    DOT National Transportation Integrated Search

    2016-01-01

    Connected vehicle safety applications are designed to increase situational awareness and reduce or eliminate crashes through vehicle-to-infrastructure, vehicle-to-vehicle, and vehicle-to-pedestrian data transmissions. Applications support advisories ...

  15. Brazed Joints Design and Allowables: Discuss Margins of Safety in Critical Brazed Structures

    NASA Technical Reports Server (NTRS)

    FLom, Yury

    2009-01-01

    This slide presentation tutorial discusses margins of safety in critical brazed structures. It reviews: (1) the present situation (2) definition of strength (3) margins of safety (4) design allowables (5) mechanical testing (6) failure criteria (7) design flowchart (8) braze gap (9) residual stresses and (10) delayed failures. This presentation addresses the strength of the brazed joints, the methods of mechanical testing, and our ability to evaluate the margins of safety of the brazed joints as it applies to the design of critical and expensive brazed assemblies.

  16. Bus operator safety : critical issues examination and model practices.

    DOT National Transportation Integrated Search

    2014-01-01

    In this study, researchers at the National Center for Transit Research performed a multi-topic comprehensive : examination of bus operator-related critical safety and personal security issues. The goals of this research : effort were to: : 1. Identif...

  17. Nuclear criticality safety evaluation of SRS 9971 shipping package

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vescovi, P.J.

    1993-02-01

    This evaluation is requested to revise the criticality evaluation used to generate Chapter 6 (Criticality Evaluation) of the Safety Analysis Report for Packaging (SARP) for shipment Of UO{sub 3} product from the Uranium Solidification Facility (USF) in the SRS 9971 shipping package. The pertinent document requesting this evaluation is included as Attachment I. The results of the evaluation are given in Attachment II which is written as Chapter 6 of a NRC format SARP.

  18. 76 FR 14641 - Defense Federal Acquisition Regulation Supplement; Identification of Critical Safety Items (DFARS...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ... Federal Acquisition Regulation Supplement; Identification of Critical Safety Items (DFARS Case 2010-D022... contract clause that clearly identifies any items being purchased that are critical safety items so that.... SUPPLEMENTARY INFORMATION: I. Background This DFARS case was initiated at the request of the Defense Contract...

  19. An Evaluation of Flash Cells Used in Critical Applications

    NASA Technical Reports Server (NTRS)

    Katz, Rich; Flowers, David; Bergevin, Keith

    2016-01-01

    Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

  20. Security for safety critical space borne systems

    NASA Technical Reports Server (NTRS)

    Legrand, Sue

    1987-01-01

    The Space Station contains safety critical computer software components in systems that can affect life and vital property. These components require a multilevel secure system that provides dynamic access control of the data and processes involved. A study is under way to define requirements for a security model providing access control through level B3 of the Orange Book. The model will be prototyped at NASA-Johnson Space Center.

  1. Medication safety infrastructure in critical-access hospitals in Florida.

    PubMed

    Winterstein, Almut G; Hartzema, Abraham G; Johns, Thomas E; De Leon, Jessica M; McDonald, Kathie; Henshaw, Zak; Pannell, Robert

    2006-03-01

    The medication safety infrastructure of critical-access hospitals (CAHs) in Florida was evaluated. Qualitative assessments, including a self-administered survey and site visits, were conducted in seven of nine CAHs between January and June 2003. The survey consisted of the Institute for Safe Medication Practices Medication Safety Self-assessment, the 2003 Joint Commission on Accreditation of Healthcare Organizations patient safety goals, health information technology (HIT) questions, and medication-use-process flow charts. On-site visits included interviews of CAH personnel who had safety responsibility and inspections of pharmacy facilities. The findings were compiled into a matrix reflecting structural and procedural components of the CAH medication safety infrastructure. The nine characteristics that emerged as targets for quality improvement (QI) were medication accessibility and storage, sterile product compounding, access to drug information, access to and utilization of patient information in medication order review, advanced safety technology, drug formularies and standardized medication protocols, safety culture, and medication reconciliation. Based on weighted importance and feasibility, QI efforts in CAHs should focus on enhancing medication order review systems, standardizing procedures for handling high-risk medications, promoting an appropriate safety culture, involvement in seamless care, and investment in HIT.

  2. Collegiate Aviation Research and Education Solutions to Critical Safety Issues. UNO Aviation Monograph Series. UNOAI Report.

    ERIC Educational Resources Information Center

    Bowen, Brent, Ed.

    This document contains four papers concerning collegiate aviation research and education solutions to critical safety issues. "Panel Proposal Titled Collegiate Aviation Research and Education Solutions to Critical Safety Issues for the Tim Forte Collegiate Aviation Safety Symposium" (Brent Bowen) presents proposals for panels on the…

  3. Evolution of safety-critical requirements post-launch

    NASA Technical Reports Server (NTRS)

    Lutz, R. R.; Mikulski, I. C.

    2001-01-01

    This paper reports the results of a small study of requirements changes to the onboard software of three spacecraft subsequent to launch. Only those requirement changes that resulted from post-launch anoma-lies (i.e., during operations) were of interest here, since the goal was to better understand the relation-ship between critical anomalies during operations and how safety-critical requirements evolve. The results of the study were surprising in that anomaly-driven, post-launch requirements changes were rarely due to previous requirements having been incorrect. Instead, changes involved new requirements (1) for the software to handle rare events or (2) for the software to compensate for hardware failures or limitations. The prevalence of new requirements as a result of post-launch anomalies suggests a need for increased requirements-engineering support of maintenance activities in these systems. The results also confirm both the difficulty and the benefits of pursuing requirements completeness, especially in terms of fault tolerance, during development of critical systems.

  4. Connected vehicle application : safety.

    DOT National Transportation Integrated Search

    2015-01-01

    Connected vehicle safety applications are designed to increase situational awareness : and reduce or eliminate crashes through vehicle-to-infrastructure (V2I), vehicle-to-vehicle (V2V), and vehicle-to-pedestrian (V2P) data transmissions. Applications...

  5. Ending on a positive: Examining the role of safety leadership decisions, behaviours and actions in a safety critical situation.

    PubMed

    Donovan, Sarah-Louise; Salmon, Paul M; Horberry, Timothy; Lenné, Michael G

    2018-01-01

    Safety leadership is an important factor in supporting safe performance in the workplace. The present case study examined the role of safety leadership during the Bingham Canyon Mine high-wall failure, a significant mining incident in which no fatalities or injuries were incurred. The Critical Decision Method (CDM) was used in conjunction with a self-reporting approach to examine safety leadership in terms of decisions, behaviours and actions that contributed to the incidents' safe outcome. Mapping the analysis onto Rasmussen's Risk Management Framework (Rasmussen, 1997), the findings demonstrate clear links between safety leadership decisions, and emergent behaviours and actions across the work system. Communication and engagement based decisions featured most prominently, and were linked to different leadership practices across the work system. Further, a core sub-set of CDM decision elements were linked to the open flow and exchange of information across the work system, which was critical to supporting the safe outcome. The findings provide practical implications for the development of safety leadership capability to support safety within the mining industry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. 29 CFR 1924.1 - Applicable safety standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Applicable safety standards. 1924.1 Section 1924.1 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY STANDARDS APPLICABLE TO WORKSHOPS AND REHABILITATION FACILITIES ASSISTED BY GRANTS § 1924...

  7. Praedicere Possumus: An Italian web-based application for predictive microbiology to ensure food safety.

    PubMed

    Polese, Pierluigi; Torre, Manuela Del; Stecchini, Mara Lucia

    2018-03-31

    The use of predictive modelling tools, which mainly describe the response of microorganisms to a particular set of environmental conditions, may contribute to a better understanding of microbial behaviour in foods. In this paper, a tertiary model, in the form of a readily available and userfriendly web-based application Praedicere Possumus (PP) is presented with research examples from our laboratories. Through the PP application, users have access to different modules, which apply a set of published models considered reliable for determining the compliance of a food product with EU safety criteria and for optimising processing throughout the identification of critical control points. The application pivots around a growth/no-growth boundary model, coupled with a growth model, and includes thermal and non-thermal inactivation models. Integrated functionalities, such as the fractional contribution of each inhibitory factor to growth probability (f) and the time evolution of the growth probability (P t ), have also been included. The PP application is expected to assist food industry and food safety authorities in their common commitment towards the improvement of food safety.

  8. A Comparison of Bus Architectures for Safety-Critical Embedded Systems

    NASA Technical Reports Server (NTRS)

    Rushby, John; Miner, Paul S. (Technical Monitor)

    2003-01-01

    We describe and compare the architectures of four fault-tolerant, safety-critical buses with a view to deducing principles common to all of them, the main differences in their design choices, and the tradeoffs made. Two of the buses come from an avionics heritage, and two from automobiles, though all four strive for similar levels of reliability and assurance. The avionics buses considered are the Honeywell SAFEbus (the backplane data bus used in the Boeing 777 Airplane Information Management System) and the NASA SPIDER (an architecture being developed as a demonstrator for certification under the new DO-254 guidelines); the automobile buses considered are the TTTech Time-Triggered Architecture (TTA), recently adopted by Audi for automobile applications, and by Honeywell for avionics and aircraft control functions, and FlexRay, which is being developed by a consortium of BMW, DaimlerChrysler, Motorola, and Philips.

  9. System Guidelines for EMC Safety-Critical Circuits: Design, Selection, and Margin Demonstration

    NASA Technical Reports Server (NTRS)

    Lawton, R. M.

    1996-01-01

    Demonstration of safety margins for critical points (circuits) has traditionally been required since it first became a part of systems-level Electromagnetic Compatibility (EMC) requirements of MIL-E-6051C. The goal of this document is to present cost-effective guidelines for ensuring adequate Electromagnetic Effects (EME) safety margins on spacecraft critical circuits. It is for the use of NASA and other government agencies and their contractors to prevent loss of life, loss of spacecraft, or unacceptable degradation. This document provides practical definition and treatment guidance to contain costs within affordable limits.

  10. Activities of the DOE Nuclear Criticality Safety Program (NCSP) at the Oak Ridge Electron Linear Accelerator (ORELA)

    NASA Astrophysics Data System (ADS)

    Valentine, Timothy E.; Leal, Luiz C.; Guber, Klaus H.

    2002-12-01

    The Department of Energy established the Nuclear Criticality Safety Program (NCSP) in response to the Recommendation 97-2 by the Defense Nuclear Facilities Safety Board. The NCSP consists of seven elements of which nuclear data measurements and evaluations is a key component. The intent of the nuclear data activities is to provide high resolution nuclear data measurements that are evaluated, validated, and formatted for use by the nuclear criticality safety community to provide improved and reliable calculations for nuclear criticality safety evaluations. High resolution capture, fission, and transmission measurements are performed at the Oak Ridge Electron Linear Accelerator (ORELA) to address the needs of the criticality safety community and to address known deficiencies in nuclear data evaluations. The activities at ORELA include measurements on both light and heavy nuclei and have been used to identify improvements in measurement techniques that greatly improve the measurement of small capture cross sections. The measurement activities at ORELA provide precise and reliable high-resolution nuclear data for the nuclear criticality safety community.

  11. 10 CFR 72.124 - Criteria for nuclear criticality safety.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Criteria for nuclear criticality safety. 72.124 Section 72.124 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  12. 10 CFR 72.124 - Criteria for nuclear criticality safety.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Criteria for nuclear criticality safety. 72.124 Section 72.124 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  13. 10 CFR 72.124 - Criteria for nuclear criticality safety.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Criteria for nuclear criticality safety. 72.124 Section 72.124 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  14. 10 CFR 72.124 - Criteria for nuclear criticality safety.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Criteria for nuclear criticality safety. 72.124 Section 72.124 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  15. 10 CFR 72.124 - Criteria for nuclear criticality safety.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Criteria for nuclear criticality safety. 72.124 Section 72.124 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) LICENSING REQUIREMENTS FOR THE INDEPENDENT STORAGE OF SPENT NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C...

  16. Criticality Safety Evaluation of Standard Criticality Safety Requirements #1-520 g Operations in PF-4

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamanaka, Alan Joseph Jr.

    Guidance has been requested from the Nuclear Criticality Safety Division (NCSD) regarding processes that involve 520 grams of fissionable material or less. This Level-3 evaluation was conducted and documented in accordance with NCS-AP-004 (Ref. 1), formerly NCS-GUIDE-01. This evaluation is being written as a generic evaluation for all operations that will be able to operate using a 520-gram mass limit. Implementation for specific operations will be performed using a Level 1 CSED, which will confirm and document that this CSED can be used for the specific operation as discussed in NCS-MEMO-17-007 (Ref. 2). This Level 3 CSED updates and supersedesmore » the analysis performed in NCS-TECH-14-014 (Ref. 3).« less

  17. Selecting an Architecture for a Safety-Critical Distributed Computer System with Power, Weight and Cost Considerations

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo

    2014-01-01

    This report presents an example of the application of multi-criteria decision analysis to the selection of an architecture for a safety-critical distributed computer system. The design problem includes constraints on minimum system availability and integrity, and the decision is based on the optimal balance of power, weight and cost. The analysis process includes the generation of alternative architectures, evaluation of individual decision criteria, and the selection of an alternative based on overall value. In this example presented here, iterative application of the quantitative evaluation process made it possible to deliberately generate an alternative architecture that is superior to all others regardless of the relative importance of cost.

  18. PRELIMINARY NUCLEAR CRITICALITY NUCLEAR SAFETY EVLAUATION FOR THE CONTAINER SURVEILLANCE AND STORAGE CAPABILITY PROJECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Low, M; Matthew02 Miller, M; Thomas Reilly, T

    2007-04-30

    Washington Safety Management Solutions (WSMS) provides criticality safety services to Washington Savannah River Company (WSRC) at the Savannah River Site. One activity at SRS is the Container Surveillance and Storage Capability (CSSC) Project, which will perform surveillances on 3013 containers (hereafter referred to as 3013s) to verify that they meet the Department of Energy (DOE) Standard (STD) 3013 for plutonium storage. The project will handle quantities of material that are greater than ANS/ANSI-8.1 single parameter mass limits, and thus required a Nuclear Criticality Safety Evaluation (NCSE). The WSMS methodology for conducting an NCSE is outlined in the WSMS methods manual.more » The WSMS methods manual currently follows the requirements of DOE-O-420.1B, DOE-STD-3007-2007, and the Washington Savannah River Company (WSRC) SCD-3 manual. DOE-STD-3007-2007 describes how a NCSE should be performed, while DOE-O-420.1B outlines the requirements for a Criticality Safety Program (CSP). The WSRC SCD-3 manual implements DOE requirements and ANS standards. NCSEs do not address the Nuclear Criticality Safety (NCS) of non-reactor nuclear facilities that may be affected by overt or covert activities of sabotage, espionage, terrorism or other security malevolence. Events which are beyond the Design Basis Accidents (DBAs) are outside the scope of a double contingency analysis.« less

  19. Criticality Safety Evaluations on the Use of 200-gram Pu Mass Limit for RHWM Waste Storage Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chou, P

    This work establishes the criticality safety technical basis to increase the fissile mass limit from 120 grams to 200 grams for Type A 55-gallon drums and their equivalents. Current RHWM fissile mass limit is 120 grams Pu for Type A 55-gallon containers and their equivalent. In order to increase the Type A 55-gallon drum limit to 200 grams, a few additional criticality safety control requirements are needed on moderators, reflectors, and array controls to ensure that the 200-gram Pu drums remain criticality safe with inadvertent criticality remains incredible. The purpose of this work is to analyze the use of 200-grammore » Pu drum mass limit for waste storage operations in Radioactive and Hazardous Waste Management (RHWM) Facilities. In this evaluation, the criticality safety controls associated with the 200-gram Pu drums are established for the RHWM waste storage operations. With the implementation of these criticality safety controls, the 200-gram Pu waste drum storage operations are demonstrated to be criticality safe and meet the double-contingency-principle requirement per DOE O 420.1.« less

  20. The use of silver nanorod array based surface enhanced Raman scattering sensor for food safety applications

    USDA-ARS?s Scientific Manuscript database

    For the advancement of preventive strategies, it is critical to develop rapid and sensitive detection methods with nanotechnology for food safety applications. This article reports the recent development on the use of aligned silver nanorod (AgNR) arrays prepared by oblique angle deposition, as surf...

  1. Static and Dynamic Verification of Critical Software for Space Applications

    NASA Astrophysics Data System (ADS)

    Moreira, F.; Maia, R.; Costa, D.; Duro, N.; Rodríguez-Dapena, P.; Hjortnaes, K.

    Space technology is no longer used only for much specialised research activities or for sophisticated manned space missions. Modern society relies more and more on space technology and applications for every day activities. Worldwide telecommunications, Earth observation, navigation and remote sensing are only a few examples of space applications on which we rely daily. The European driven global navigation system Galileo and its associated applications, e.g. air traffic management, vessel and car navigation, will significantly expand the already stringent safety requirements for space based applications Apart from their usefulness and practical applications, every single piece of onboard software deployed into the space represents an enormous investment. With a long lifetime operation and being extremely difficult to maintain and upgrade, at least when comparing with "mainstream" software development, the importance of ensuring their correctness before deployment is immense. Verification &Validation techniques and technologies have a key role in ensuring that the onboard software is correct and error free, or at least free from errors that can potentially lead to catastrophic failures. Many RAMS techniques including both static criticality analysis and dynamic verification techniques have been used as a means to verify and validate critical software and to ensure its correctness. But, traditionally, these have been isolated applied. One of the main reasons is the immaturity of this field in what concerns to its application to the increasing software product(s) within space systems. This paper presents an innovative way of combining both static and dynamic techniques exploiting their synergy and complementarity for software fault removal. The methodology proposed is based on the combination of Software FMEA and FTA with Fault-injection techniques. The case study herein described is implemented with support from two tools: The SoftCare tool for the SFMEA and SFTA

  2. Mission and Safety Critical (MASC): An EVACS simulation with nested transactions

    NASA Technical Reports Server (NTRS)

    Auty, David; Atkinson, Colin; Randall, Charlie

    1992-01-01

    The Extra-Vehicular Activity Control System (EVACS) Simulation with Nested Transactions, a recent effort of the MISSION Kernel Team, is documented. The EVACS simulation is a simulation of some aspects of the Extra-Vehicular Activity Control System, in particular, just the selection of communication frequencies. The simulation is a tool to explore mission and safety critical (MASC) applications. For the purpose of this effort, its current definition is quite narrow serving only as a starting point for prototyping purposes. (Note that EVACS itself has been supplanted in a larger scenario of a lunar outpost with astronauts and a lunar rover). The frequency selection scenario was modified to embed its processing in nested transactions. Again as a first step, only two aspects of transaction support were implemented in this prototype: architecture and state recovery. Issues of concurrency and distribution are yet to be addressed.

  3. Critical Review of Commercial Secondary Lithium-Ion Battery Safety Standards

    NASA Astrophysics Data System (ADS)

    Jones, Harry P.; Chapin, Thomas, J.; Tabaddor, Mahmod

    2010-09-01

    The development of Li-ion cells with greater energy density has lead to safety concerns that must be carefully assessed as Li-ion cells power a wide range of products from consumer electronics to electric vehicles to space applications. Documented field failures and product recalls for Li-ion cells, mostly for consumer electronic products, highlight the risk of fire, smoke, and even explosion. These failures have been attributed to the occurrence of internal short circuits and the subsequent thermal runaway that can lead to fire and explosion. As packaging for some applications include a large number of cells, the risk of failure is likely to be magnified. To address concerns about the safety of battery powered products, safety standards have been developed. This paper provides a review of various international safety standards specific to lithium-ion cells. This paper shows that though the standards are harmonized on a host of abuse conditions, most lack a test simulating internal short circuits. This paper describes some efforts to introduce internal short circuit tests into safety standards.

  4. Some Challenges in the Design of Human-Automation Interaction for Safety-Critical Systems

    NASA Technical Reports Server (NTRS)

    Feary, Michael S.; Roth, Emilie

    2014-01-01

    Increasing amounts of automation are being introduced to safety-critical domains. While the introduction of automation has led to an overall increase in reliability and improved safety, it has also introduced a class of failure modes, and new challenges in risk assessment for the new systems, particularly in the assessment of rare events resulting from complex inter-related factors. Designing successful human-automation systems is challenging, and the challenges go beyond good interface development (e.g., Roth, Malin, & Schreckenghost 1997; Christoffersen & Woods, 2002). Human-automation design is particularly challenging when the underlying automation technology generates behavior that is difficult for the user to anticipate or understand. These challenges have been recognized in several safety-critical domains, and have resulted in increased efforts to develop training, procedures, regulations and guidance material (CAST, 2008, IAEA, 2001, FAA, 2013, ICAO, 2012). This paper points to the continuing need for new methods to describe and characterize the operational environment within which new automation concepts are being presented. We will describe challenges to the successful development and evaluation of human-automation systems in safety-critical domains, and describe some approaches that could be used to address these challenges. We will draw from experience with the aviation, spaceflight and nuclear power domains.

  5. Applications of near-infrared spectroscopy in food safety evaluation and control: a review of recent research advances.

    PubMed

    Qu, Jia-Huan; Liu, Dan; Cheng, Jun-Hu; Sun, Da-Wen; Ma, Ji; Pu, Hongbin; Zeng, Xin-An

    2015-01-01

    Food safety is a critical public concern, and has drawn great attention in society. Consequently, developments of rapid, robust, and accurate methods and techniques for food safety evaluation and control are required. As a nondestructive and convenient tool, near-infrared spectroscopy (NIRS) has been widely shown to be a promising technique for food safety inspection and control due to its huge advantages of speed, noninvasive measurement, ease of use, and minimal sample preparation requirement. This review presents the fundamentals of NIRS and focuses on recent advances in its applications, during the last 10 years of food safety control, in meat, fish and fishery products, edible oils, milk and dairy products, grains and grain products, fruits and vegetables, and others. Based upon these applications, it can be demonstrated that NIRS, combined with chemometric methods, is a powerful tool for food safety surveillance and for the elimination of the occurrence of food safety problems. Some disadvantages that need to be solved or investigated with regard to the further development of NIRS are also discussed.

  6. A Practical Risk Assessment Methodology for Safety-Critical Train Control Systems

    DOT National Transportation Integrated Search

    2009-07-01

    This project proposes a Practical Risk Assessment Methodology (PRAM) for analyzing railroad accident data and assessing the risk and benefit of safety-critical train control systems. This report documents in simple steps the algorithms and data input...

  7. An aspect-oriented approach for designing safety-critical systems

    NASA Astrophysics Data System (ADS)

    Petrov, Z.; Zaykov, P. G.; Cardoso, J. P.; Coutinho, J. G. F.; Diniz, P. C.; Luk, W.

    The development of avionics systems is typically a tedious and cumbersome process. In addition to the required functions, developers must consider various and often conflicting non-functional requirements such as safety, performance, and energy efficiency. Certainly, an integrated approach with a seamless design flow that is capable of requirements modelling and supporting refinement down to an actual implementation in a traceable way, may lead to a significant acceleration of development cycles. This paper presents an aspect-oriented approach supported by a tool chain that deals with functional and non-functional requirements in an integrated manner. It also discusses how the approach can be applied to development of safety-critical systems and provides experimental results.

  8. 75 FR 8239 - School Food Safety Program Based on Hazard Analysis and Critical Control Point Principles (HACCP...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-24

    ... 0584-AD65 School Food Safety Program Based on Hazard Analysis and Critical Control Point Principles... Safety Program Based on Hazard Analysis and Critical Control Point Principles (HACCP) was published on... of Management and Budget (OMB) cleared the associated information collection requirements (ICR) on...

  9. Structural empowerment and patient safety culture among registered nurses working in adult critical care units.

    PubMed

    Armellino, Donna; Quinn Griffin, Mary T; Fitzpatrick, Joyce J

    2010-10-01

    The aim of the present study was to examine the relationship between structural empowerment and patient safety culture among staff level Registered Nurses (RNs) within adult critical care units (ACCU). There is literature to support the value of RNs' structurally empowered work environments and emerging literature towards patient safety culture; the link between empowerment and patient safety culture is being discovered. A sample of 257 RNs, working within adult critical care of a tertiary hospital in the United States, was surveyed. Instruments included a background data sheet, the Conditions of Workplace Effectiveness and the Hospital Survey on Patient Safety Culture. Structural empowerment and patient safety culture were significantly correlated. As structural empowerment increased so did the RNs' perception of patient safety culture. To foster patient safety culture, nurse leaders should consider providing structurally empowering work environments for RNs. This study contributes to the body of knowledge linking structural empowerment and patient safety culture. Results link structurally empowered RNs and increased patient safety culture, essential elements in delivering efficient, competent, quality care. They inform nursing management of key factors in the nurses' environment that promote safe patient care environments. © 2010 The Authors. Journal compilation © 2010 Blackwell Publishing Ltd.

  10. [Technical specification for clinical application of critical ultrasonography].

    PubMed

    Yin, M G; Wang, X T; Liu, D W; Chao, Y G; Guan, X D; Kang, Y; Yan, J; Ma, X C; Tang, Y Q; Hu, Z J; Yu, K J; Chen, D C; Ai, Y H; Zhang, L N; Zhang, H M; Wu, J; Liu, L X; Zhu, R; He, W; Zhang, Q; Ding, X; Li, L; Li, Y; Liu, H T; Zeng, Q B; Si, X; Chen, H; Zhang, J W; Xu, Q H; Chen, W J; Chen, X K; Huang, D Z; Cai, S H; Shang, X L; Guan, J; Du, J; Zhao, L; Wang, M J; Cui, S; Wang, X M; Zhou, R; Zeng, X Y; Wang, Y P; Lyu, L W; Zhu, W H; Zhu, Y; Duan, J; Yang, J; Yang, H

    2018-06-01

    Critical ultrasonography(CUS) is different from the traditional diagnostic ultrasound, the examiner and interpreter of the image are critical care medicine physicians. The core content of CUS is to evaluate the pathophysiological changes of organs and systems and etiology changes. With the idea of critical care medicine as the soul, it can integrate the above information and clinical information, bedside real-time diagnosis and titration treatment, and evaluate the therapeutic effect so as to improve the outcome. CUS is a traditional technique which is applied as a new application method. The consensus of experts on critical ultrasonography in China released in 2016 put forward consensus suggestions on the concept, implementation and application of CUS. It should be further emphasized that the accurate and objective assessment and implementation of CUS requires the standardization of ultrasound image acquisition and the need to establish a CUS procedure. At the same time, the standardized training for CUS accepted by critical care medicine physicians requires the application of technical specifications, and the establishment of technical specifications is the basis for the quality control and continuous improvement of CUS. Chinese Critical Ultrasound Study Group and Critical Hemodynamic Therapy Collabration Group, based on the rich experience of clinical practice in critical care and research, combined with the essence of CUS, to learn the traditional ultrasonic essence, established the clinical application technical specifications of CUS, including in five parts: basic view and relevant indicators to obtain in CUS; basic norms for viscera organ assessment and special assessment; standardized processes and systematic inspection programs; examples of CUS applications; CUS training and the application of qualification certification. The establishment of applied technology standard is helpful for standardized training and clinical correct implementation. It is helpful

  11. Connected commercial vehicles — retrofit safety device kit project : safety applications and development plan.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  12. Criticality Safety Analysis on the Mixed Be, Nat-U, and C (Graphite) Reflectors in 55-Gallon Waste Drums and Their Equivalents for HWM Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chou, P

    The objective of this analysis is to develop and establish the technical basis on the criticality safety controls for the storage of mixed beryllium (Be), natural uranium (Nat-U), and carbon (C)/graphite reflectors in 55-gallon waste containers and/or their equivalents in Hazardous Waste Management (HWM) facilities. Based on the criticality safety limits and controls outlined in Section 3.0, the operations involving the use of mixed-reflector drums satisfy the double-contingency principle as required by DOE Order 420.1 and are therefore criticality safe. The mixed-reflector mass limit is 120 grams for each 55-gallon drum or its equivalent. a reflector waiver of 50 gramsmore » is allowed for Be, Nat-U, or C/graphite combined. The waived reflectors may be excluded from the reflector mass calculations when determining if a drum is compliant. The mixed-reflector drums are allowed to mix with the typical 55-gallon one-reflector drums with a Pu mass limit of 120 grams. The fissile mass limit for the mixed-reflector container is 65 grams of Pu equivalent each. The corresponding reflector mass limits are 300 grams of Be, and/or 100 kilograms of Nat-U, and/or 110 kilograms of C/graphite for each container. All other unaffected control parameters for the one-reflector containers remain in effect for the mixed-reflector drums. For instance, Superior moderators, such as TrimSol, Superla white mineral oil No. 9, paraffin, and polyethylene, are allowed in unlimited quantities. Hydrogenous materials with a hydrogen density greater than 0.133 gram/cc are not allowed. Also, an isolation separation of no less than 76.2 cm (30-inch) is required between a mixed array and any other array. Waste containers in the action of being transported are exempted from this 76.2-cm (30-inch) separation requirement. All deviations from the CS controls and mass limits listed in Section 3.0 will require individual criticality safety analyses on a case-by-case basis for each of them to confirm their

  13. Predicting Fatigue and Psychophysiological Test Performance from Speech for Safety-Critical Environments.

    PubMed

    Baykaner, Khan Richard; Huckvale, Mark; Whiteley, Iya; Andreeva, Svetlana; Ryumin, Oleg

    2015-01-01

    Automatic systems for estimating operator fatigue have application in safety-critical environments. A system which could estimate level of fatigue from speech would have application in domains where operators engage in regular verbal communication as part of their duties. Previous studies on the prediction of fatigue from speech have been limited because of their reliance on subjective ratings and because they lack comparison to other methods for assessing fatigue. In this paper, we present an analysis of voice recordings and psychophysiological test scores collected from seven aerospace personnel during a training task in which they remained awake for 60 h. We show that voice features and test scores are affected by both the total time spent awake and the time position within each subject's circadian cycle. However, we show that time spent awake and time-of-day information are poor predictors of the test results, while voice features can give good predictions of the psychophysiological test scores and sleep latency. Mean absolute errors of prediction are possible within about 17.5% for sleep latency and 5-12% for test scores. We discuss the implications for the use of voice as a means to monitor the effects of fatigue on cognitive performance in practical applications.

  14. Predicting Fatigue and Psychophysiological Test Performance from Speech for Safety-Critical Environments

    PubMed Central

    Baykaner, Khan Richard; Huckvale, Mark; Whiteley, Iya; Andreeva, Svetlana; Ryumin, Oleg

    2015-01-01

    Automatic systems for estimating operator fatigue have application in safety-critical environments. A system which could estimate level of fatigue from speech would have application in domains where operators engage in regular verbal communication as part of their duties. Previous studies on the prediction of fatigue from speech have been limited because of their reliance on subjective ratings and because they lack comparison to other methods for assessing fatigue. In this paper, we present an analysis of voice recordings and psychophysiological test scores collected from seven aerospace personnel during a training task in which they remained awake for 60 h. We show that voice features and test scores are affected by both the total time spent awake and the time position within each subject’s circadian cycle. However, we show that time spent awake and time-of-day information are poor predictors of the test results, while voice features can give good predictions of the psychophysiological test scores and sleep latency. Mean absolute errors of prediction are possible within about 17.5% for sleep latency and 5–12% for test scores. We discuss the implications for the use of voice as a means to monitor the effects of fatigue on cognitive performance in practical applications. PMID:26380259

  15. The potential application of behavior-based safety in the trucking industry

    DOT National Transportation Integrated Search

    2000-04-01

    Behavior-based safety (BBS) is a set of methods to improve safety performance in the workplace by engaging workers in the improvement process, identifying critical safety behaviors, performing observations to gather data, providing feedback to encour...

  16. Shielding calculation and criticality safety analysis of spent fuel transportation cask in research reactors.

    PubMed

    Mohammadi, A; Hassanzadeh, M; Gharib, M

    2016-02-01

    In this study, shielding calculation and criticality safety analysis were carried out for general material testing reactor (MTR) research reactors interim storage and relevant transportation cask. During these processes, three major terms were considered: source term, shielding, and criticality calculations. The Monte Carlo transport code MCNP5 was used for shielding calculation and criticality safety analysis and ORIGEN2.1 code for source term calculation. According to the results obtained, a cylindrical cask with body, top, and bottom thicknesses of 18, 13, and 13 cm, respectively, was accepted as the dual-purpose cask. Furthermore, it is shown that the total dose rates are below the normal transport criteria that meet the standards specified. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Educating Next Generation Nuclear Criticality Safety Engineers at the Idaho National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. D. Bess; J. B. Briggs; A. S. Garcia

    2011-09-01

    One of the challenges in educating our next generation of nuclear safety engineers is the limitation of opportunities to receive significant experience or hands-on training prior to graduation. Such training is generally restricted to on-the-job-training before this new engineering workforce can adequately provide assessment of nuclear systems and establish safety guidelines. Participation in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and the International Reactor Physics Experiment Evaluation Project (IRPhEP) can provide students and young professionals the opportunity to gain experience and enhance critical engineering skills. The ICSBEP and IRPhEP publish annual handbooks that contain evaluations of experiments along withmore » summarized experimental data and peer-reviewed benchmark specifications to support the validation of neutronics codes, nuclear cross-section data, and the validation of reactor designs. Participation in the benchmark process not only benefits those who use these Handbooks within the international community, but provides the individual with opportunities for professional development, networking with an international community of experts, and valuable experience to be used in future employment. Traditionally students have participated in benchmarking activities via internships at national laboratories, universities, or companies involved with the ICSBEP and IRPhEP programs. Additional programs have been developed to facilitate the nuclear education of students while participating in the benchmark projects. These programs include coordination with the Center for Space Nuclear Research (CSNR) Next Degree Program, the Collaboration with the Department of Energy Idaho Operations Office to train nuclear and criticality safety engineers, and student evaluations as the basis for their Master's thesis in nuclear engineering.« less

  18. Confirming criticality safety of TRU waste with neutron measurements and risk analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winn, W.G.; Hochel, R.D.

    1992-04-01

    The criticality safety of {sup 239}Pu in 55-gallon drums stored in TRU waste containers (culverts) is confirmed using NDA neutron measurements and risk analyses. The neutron measurements yield a {sup 239}Pu mass and k{sub eff} for a culvert, which contains up to 14 drums. Conservative probabilistic risk analyses were developed for both drums and culverts. Overall {sup 239}Pu mass estimates are less than a calculated safety limit of 2800 g per culvert. The largest measured k{sub eff} is 0.904. The largest probability for a critical drum is 6.9 {times} 10{sup {minus}8} and that for a culvert is 1.72 {times} 10{supmore » {minus}7}. All examined suspect culverts, totaling 118 in number, are appraised as safe based on these observations.« less

  19. An Approach for Validating Actinide and Fission Product Burnup Credit Criticality Safety Analyses-Isotopic Composition Predictions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Radulescu, Georgeta; Gauld, Ian C; Ilas, Germina

    2011-01-01

    The expanded use of burnup credit in the United States (U.S.) for storage and transport casks, particularly in the acceptance of credit for fission products, has been constrained by the availability of experimental fission product data to support code validation. The U.S. Nuclear Regulatory Commission (NRC) staff has noted that the rationale for restricting the Interim Staff Guidance on burnup credit for storage and transportation casks (ISG-8) to actinide-only is based largely on the lack of clear, definitive experiments that can be used to estimate the bias and uncertainty for computational analyses associated with using burnup credit. To address themore » issues of burnup credit criticality validation, the NRC initiated a project with the Oak Ridge National Laboratory to (1) develop and establish a technically sound validation approach for commercial spent nuclear fuel (SNF) criticality safety evaluations based on best-available data and methods and (2) apply the approach for representative SNF storage and transport configurations/conditions to demonstrate its usage and applicability, as well as to provide reference bias results. The purpose of this paper is to describe the isotopic composition (depletion) validation approach and resulting observations and recommendations. Validation of the criticality calculations is addressed in a companion paper at this conference. For isotopic composition validation, the approach is to determine burnup-dependent bias and uncertainty in the effective neutron multiplication factor (keff) due to bias and uncertainty in isotopic predictions, via comparisons of isotopic composition predictions (calculated) and measured isotopic compositions from destructive radiochemical assay utilizing as much assay data as is available, and a best-estimate Monte Carlo based method. This paper (1) provides a detailed description of the burnup credit isotopic validation approach and its technical bases, (2) describes the application of the

  20. Reductions in invasive device use and care costs after institution of a daily safety checklist in a pediatric critical care unit.

    PubMed

    Tarrago, Rod; Nowak, Jeffrey E; Leonard, Christopher S; Payne, Nathaniel R

    2014-06-01

    In the critical care unit, complexity of care can contribute to both medical errors and increased costs, particularly when clinicians are forced to rely on memory. Checklists can be used to improve safety and reduce cost. A number of omission-related adverse events in 2010 prompted the development of a checklist to reduce the possibility of similar future events. The PICU Safety Checklist was implemented in the pediatric ICU (PICU) at Children's Hospitals and Clinics of Minnesota. During a 21-month period, the checklist was used to prompt the care team to address quality and safety items during rounds. The initial checklist was paper, with two subsequent versions being incorporated into the electronic medical record (EMR). The daily safety checklist was successfully implemented in the PICU. Work-flow improvements based on regular multidisciplinary feedback led to more consistent use of the checklist. Improvements on all quality and safety metrics were identified, including invasive device use, medication costs, antibiotic and laboratory test use, and compliance with standards of care. Staff satisfaction rates were > 80% for safety, communication, and collaboration. By using a daily safety checklist in the pediatric critical care unit, we improved quality and safety, as well as the collaborative culture among all clinicians. Incorporating the checklist into the EMR improved compliance and accountability, ensuring its application to all patients. Clinicians now often individually address many checklist items outside the formal rounding process, indicating that the checklist content has become part of their usual practice. A successful implementation showing tangible clinical improvements can lead to interest and adoption in other clinical areas within the institution.

  1. Critical thinking in clinical nurse education: application of Paul's model of critical thinking.

    PubMed

    Andrea Sullivan, E

    2012-11-01

    Nurse educators recognize that many nursing students have difficulty in making decisions in clinical practice. The ability to make effective, informed decisions in clinical practice requires that nursing students know and apply the processes of critical thinking. Critical thinking is a skill that develops over time and requires the conscious application of this process. There are a number of models in the nursing literature to assist students in the critical thinking process; however, these models tend to focus solely on decision making in hospital settings and are often complex to actualize. In this paper, Paul's Model of Critical Thinking is examined for its application to nursing education. I will demonstrate how the model can be used by clinical nurse educators to assist students to develop critical thinking skills in all health care settings in a way that makes critical thinking skills accessible to students. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Feasibility and safety of virtual-reality-based early neurocognitive stimulation in critically ill patients.

    PubMed

    Turon, Marc; Fernandez-Gonzalo, Sol; Jodar, Mercè; Gomà, Gemma; Montanya, Jaume; Hernando, David; Bailón, Raquel; de Haro, Candelaria; Gomez-Simon, Victor; Lopez-Aguilar, Josefina; Magrans, Rudys; Martinez-Perez, Melcior; Oliva, Joan Carles; Blanch, Lluís

    2017-12-01

    Growing evidence suggests that critical illness often results in significant long-term neurocognitive impairments in one-third of survivors. Although these neurocognitive impairments are long-lasting and devastating for survivors, rehabilitation rarely occurs during or after critical illness. Our aim is to describe an early neurocognitive stimulation intervention based on virtual reality for patients who are critically ill and to present the results of a proof-of-concept study testing the feasibility, safety, and suitability of this intervention. Twenty critically ill adult patients undergoing or having undergone mechanical ventilation for ≥24 h received daily 20-min neurocognitive stimulation sessions when awake and alert during their ICU stay. The difficulty of the exercises included in the sessions progressively increased over successive sessions. Physiological data were recorded before, during, and after each session. Safety was assessed through heart rate, peripheral oxygen saturation, and respiratory rate. Heart rate variability analysis, an indirect measure of autonomic activity sensitive to cognitive demands, was used to assess the efficacy of the exercises in stimulating attention and working memory. Patients successfully completed the sessions on most days. No sessions were stopped early for safety concerns, and no adverse events occurred. Heart rate variability analysis showed that the exercises stimulated attention and working memory. Critically ill patients considered the sessions enjoyable and relaxing without being overly fatiguing. The results in this proof-of-concept study suggest that a virtual-reality-based neurocognitive intervention is feasible, safe, and tolerable, stimulating cognitive functions and satisfying critically ill patients. Future studies will evaluate the impact of interventions on neurocognitive outcomes. Trial registration Clinical trials.gov identifier: NCT02078206.

  3. System Guidelines for EMC Safety-Critical Circuits: Design, Selection, and Margin Demonstration

    NASA Technical Reports Server (NTRS)

    Lawton, R. M.

    1996-01-01

    Demonstration of required safety margins on critical electrical/electronic circuits in large complex systems has become an implementation and cost problem. These margins are the difference between the activation level of the circuit and the electrical noise on the circuit in the actual operating environment. This document discusses the origin of the requirement and gives a detailed process flow for the identification of the system electromagnetic compatibility (EMC) critical circuit list. The process flow discusses the roles of engineering disciplines such as systems engineering, safety, and EMC. Design and analysis guidelines are provided to assist the designer in assuring the system design has a high probability of meeting the margin requirements. Examples of approaches used on actual programs (Skylab and Space Shuttle Solid Rocket Booster) are provided to show how variations of the approach can be used successfully.

  4. Predictive Microbiology and Food Safety Applications

    USDA-ARS?s Scientific Manuscript database

    Mathematical modeling is the science of systematic study of recurrent events or phenomena. When models are properly developed, their applications may save costs and time. For microbial food safety research and applications, predictive microbiology models may be developed based on the fact that most ...

  5. Critical factors and paths influencing construction workers' safety risk tolerances.

    PubMed

    Wang, Jiayuan; Zou, Patrick X W; Li, Penny P

    2016-08-01

    While workers' safety risk tolerances have been regarded as a main reason for their unsafe behaviors, little is known about why different people have different risk tolerances even when confronting the same situation. The aim of this research is to identify the critical factors and paths that influence workers' safety risk tolerance and to explore how they contribute to accident causal model from a system thinking perceptive. A number of methods were carried out to analyze the data collected through interviews and questionnaire surveys. In the first and second steps of the research, factor identification, factor ranking and factor analysis were carried out, and the results show that workers' safety risk tolerance can be influenced by four groups of factors, namely: (1) personal subjective perception; (2) work knowledge and experiences; (3) work characteristics; and (4) safety management. In the third step of the research, hypothetical influencing path model was developed and tested by using structural equation modeling (SEM). It is found that the effects of external factors (safety management and work characteristics) on risk tolerance are larger than that of internal factors (personal subjective perception and work knowledge & experiences). Specifically, safety management contributes the most to workers' safety risk tolerance through its direct effect and indirect effect; while personal subjective perception comes the second and can act as an intermedia for work characteristics. This research provides an in-depth insight of workers' unsafe behaviors by depicting the contributing factors as shown in the accident causal model developed in this research. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Experimental criticality specifications. An annotated bibliography through 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paxton, H.C.

    1978-05-01

    The compilation of approximately 300 references gives sources of experimental criticality parameters of systems containing /sup 235/U, /sup 233/U, and /sup 239/Pu. The intent is to cover basic data for criticality safety applications. The references are arranged by subject.

  7. System modeling with the DISC framework: evidence from safety-critical domains.

    PubMed

    Reiman, Teemu; Pietikäinen, Elina; Oedewald, Pia; Gotcheva, Nadezhda

    2012-01-01

    The objective of this paper is to illustrate the development and application of the Design for Integrated Safety Culture (DISC) framework for system modeling by evaluating organizational potential for safety in nuclear and healthcare domains. The DISC framework includes criteria for good safety culture and a description of functions that the organization needs to implement in order to orient the organization toward the criteria. Three case studies will be used to illustrate the utilization of the DISC framework in practice.

  8. CSER 98-003: Criticality safety evaluation report for PFP glovebox HC-21A with button can opening

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ERICKSON, D.G.

    1999-02-23

    Glovebox HC-21A is an enclosure where cans containing plutonium metal buttons or other plutonium bearing materials are prepared for thermal stabilization in the muffle furnaces. The Inert Atmosphere Confinement (IAC), a new feature added to Glovebox HC-21A, allows the opening of containers suspected of containing hydrided plutonium metal. The argon atmosphere in the IAC prevents an adverse reaction between oxygen and the hydride. The hydride is then stabilized in a controlled manner to prevent glovebox over pressurization. After removal from the containers, the plutonium metal buttons or plutonium bearing materials will be placed into muffle furnace boats and then bemore » sent to one of the muffle furnace gloveboxes for stabilization. The materials allowed to be brought into GloveboxHC-21 A are limited to those with a hydrogen to fissile atom ratio (H/X) {le} 20. Glovebox HC-21A is classified as a DRY glovebox, meaning it has no internal liquid lines, and no free liquids or solutions are allowed to be introduced. The double contingency principle states that designs shall incorporate sufficient factors of safety to require at least two unlikely, independent, and concurrent changes in process conditions before a criticality accident is possible. This criticality safety evaluation report (CSER) shows that the operations to be performed in this glovebox are safe from a criticality standpoint. No single identified event that causes criticality controls to be lost exceeded the criticality safety limit of k{sub eff} = 0.95. Therefore, this CSER meets the requirements for a criticality analysis contained in the Hanford Site Nuclear Criticality Safety Manual, HNF-PRO-334, and meets the double contingency principle.« less

  9. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  10. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  11. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  12. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  13. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  14. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  15. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 5 2012-10-01 2012-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  16. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  17. 49 CFR 385.119 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.119 Applicability of safety fitness and enforcement procedures. At all times during which a Mexico-domiciled motor...

  18. 49 CFR 385.717 - Applicability of safety fitness and enforcement procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 5 2014-10-01 2014-10-01 false Applicability of safety fitness and enforcement... REGULATIONS SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.717 Applicability of safety fitness and enforcement procedures. At all times during which a non-North America...

  19. Testing of Safety-Critical Software Embedded in an Artificial Heart

    NASA Astrophysics Data System (ADS)

    Cha, Sungdeok; Jeong, Sehun; Yoo, Junbeom; Kim, Young-Gab

    Software is being used more frequently to control medical devices such as artificial heart or robotic surgery system. While much of software safety issues in such systems are similar to other safety-critical systems (e.g., nuclear power plants), domain-specific properties may warrant development of customized techniques to demonstrate fitness of the system on patients. In this paper, we report results of a preliminary analysis done on software controlling a Hybrid Ventricular Assist Device (H-VAD) developed by Korea Artificial Organ Centre (KAOC). It is a state-of-the-art artificial heart which completed animal testing phase. We performed software testing in in-vitro experiments and animal experiments. An abnormal behaviour, never detected during extensive in-vitro analysis and animal testing, was found.

  20. Four Pillars for Improving the Quality of Safety-Critical Software-Reliant Systems

    DTIC Science & Technology

    2013-04-01

    Studies of safety-critical software-reliant systems developed using the current practices of build-then-test show that requirements and architecture ... design defects make up approximately 70% of all defects, many system level related to operational quality attributes, and 80% of these defects are

  1. Criticality safety strategy for the Fuel Cycle Facility electrorefiner at Argonne National Laboratory, West

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mariani, R.D.; Benedict, R.W.; Lell, R.M.

    1993-09-01

    The Integral Fast Reactor being developed by Argonne National Laboratory (ANL) combines the advantages of metal-fueled, liquid-metal-cooled reactors and a closed fuel cycle. Presently, the Fuel Cycle Facility (FCF) at ANL-West in Idaho Falls, Idaho is being modified to recycle spent metallic fuel from Experimental Breeder Reactor II as part of a demonstration project sponsored by the Department of Energy. A key component of the FCF is the electrorefiner (ER) in which the actinides are separated from the fission products. In the electrorefining process, the metal fuel is anodically dissolved into a high-temperature molten salt and refined uranium or uranium/plutoniummore » products are deposited at cathodes. In this report, the criticality safety strategy for the FCF ER is summarized. FCF ER operations and processes formed the basis for evaluating criticality safety and control during actinide metal fuel refining. In order to show criticality safety for the FCF ER, the reference operating conditions for the ER had to be defined. Normal operating envelopes (NOES) were then defined to bracket the important operating conditions. To keep the operating conditions within their NOES, process controls were identified that can be used to regulate the actinide forms and content within the ER. A series of operational checks were developed for each operation that wig verify the extent or success of an operation. The criticality analysis considered the ER operating conditions at their NOE values as the point of departure for credible and incredible failure modes. As a result of the analysis, FCF ER operations were found to be safe with respect to criticality.« less

  2. Nuclear criticality safety evaluation of SRS 9971 shipping package. [SRS (Savannah River Site)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vescovi, P.J.

    1993-02-01

    This evaluation is requested to revise the criticality evaluation used to generate Chapter 6 (Criticality Evaluation) of the Safety Analysis Report for Packaging (SARP) for shipment Of UO[sub 3] product from the Uranium Solidification Facility (USF) in the SRS 9971 shipping package. The pertinent document requesting this evaluation is included as Attachment I. The results of the evaluation are given in Attachment II which is written as Chapter 6 of a NRC format SARP.

  3. Nuclear criticality safety assessment of the low level radioactive waste disposal facility trenches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kahook, S.D.

    1994-04-01

    Results of the analyses performed to evaluate the possibility of nuclear criticality in the Low Level Radioactive Waste Disposal Facility (LLRWDF) trenches are documented in this report. The studies presented in this document are limited to assessment of the possibility of criticality due to existing conditions in the LLRWDF. This document does not propose nor set limits for enriched uranium (EU) burial in the LLRWDF and is not a nuclear criticality safety evaluation nor analysis. The calculations presented in the report are Level 2 calculations as defined by the E7 Procedure 2.31, Engineering Calculations.

  4. Assuring NASA's Safety and Mission Critical Software

    NASA Technical Reports Server (NTRS)

    Deadrick, Wesley

    2015-01-01

    What is IV&V? Independent Verification and Validation (IV&V) is an objective examination of safety and mission critical software processes and products. Independence: 3 Key parameters: Technical Independence; Managerial Independence; Financial Independence. NASA IV&V perspectives: Will the system's software: Do what it is supposed to do?; Not do what it is not supposed to do?; Respond as expected under adverse conditions?. Systems Engineering: Determines if the right system has been built and that it has been built correctly. IV&V Technical Approaches: Aligned with IEEE 1012; Captured in a Catalog of Methods; Spans the full project lifecycle. IV&V Assurance Strategy: The IV&V Project's strategy for providing mission assurance; Assurance Strategy is driven by the specific needs of an individual project; Implemented via an Assurance Design; Communicated via Assurance Statements.

  5. Definition and means of maintaining the criticality detectors and alarms portion of the PFP safety envelope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, W.F.

    The purpose of this document is to provide the definition and means of maintaining the Safety Envelope (SE) related to the Criticality Alarm System (CAS). This document provides amplification of the Limiting Condition for Operation (LCO) described in the Plutonium Finishing Plant (PFP) Operational Safety Requirements (OSR), WHC-SD-CP-OSR-010, Rev. 0, 1994, Section 3.1.2, Criticality Detectors and Alarms. This document, with its appendices, provides the following: (1) System functional requirements for determining system operability (Section 3); (2) A list of annotated system block diagrams which indicate the safety envelope boundaries (Appendix C); (3) A list of the Safety Class 1 andmore » 2 Safety Envelope (SC-1/2 SE) equipment for input into the Master Component Index (Appendix B); (4) Functional requirements for individual SC-1/2 SE components, including appropriate setpoints and process parameters (Section 6 and Appendix A); (5) A list of the operational, maintenance and surveillance procedures necessary to operate and maintain the SC-1/2 SE components as required by the LCO (Section 6 and Appendix A).« less

  6. Validation of Safety-Critical Systems for Aircraft Loss-of-Control Prevention and Recovery

    NASA Technical Reports Server (NTRS)

    Belcastro, Christine M.

    2012-01-01

    Validation of technologies developed for loss of control (LOC) prevention and recovery poses significant challenges. Aircraft LOC can result from a wide spectrum of hazards, often occurring in combination, which cannot be fully replicated during evaluation. Technologies developed for LOC prevention and recovery must therefore be effective under a wide variety of hazardous and uncertain conditions, and the validation framework must provide some measure of assurance that the new vehicle safety technologies do no harm (i.e., that they themselves do not introduce new safety risks). This paper summarizes a proposed validation framework for safety-critical systems, provides an overview of validation methods and tools developed by NASA to date within the Vehicle Systems Safety Project, and develops a preliminary set of test scenarios for the validation of technologies for LOC prevention and recovery

  7. Sensitivity-Uncertainty Techniques for Nuclear Criticality Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Forrest B.; Rising, Michael Evan; Alwin, Jennifer Louise

    2017-08-07

    The sensitivity and uncertainty analysis course will introduce students to k eff sensitivity data, cross-section uncertainty data, how k eff sensitivity data and k eff uncertainty data are generated and how they can be used. Discussion will include how sensitivity/uncertainty data can be used to select applicable critical experiments, to quantify a defensible margin to cover validation gaps and weaknesses, and in development of upper subcritical limits.

  8. A review of the current state-of-the-art methodology for handling bias and uncertainty in performing criticality safety evaluations. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Disney, R.K.

    1994-10-01

    The methodology for handling bias and uncertainty when calculational methods are used in criticality safety evaluations (CSE`s) is a rapidly evolving technology. The changes in the methodology are driven by a number of factors. One factor responsible for changes in the methodology for handling bias and uncertainty in CSE`s within the overview of the US Department of Energy (DOE) is a shift in the overview function from a ``site`` perception to a more uniform or ``national`` perception. Other causes for change or improvement in the methodology for handling calculational bias and uncertainty are; (1) an increased demand for benchmark criticalsmore » data to expand the area (range) of applicability of existing data, (2) a demand for new data to supplement existing benchmark criticals data, (3) the increased reliance on (or need for) computational benchmarks which supplement (or replace) experimental measurements in critical assemblies, and (4) an increased demand for benchmark data applicable to the expanded range of conditions and configurations encountered in DOE site restoration and remediation.« less

  9. Critical review of controlled release packaging to improve food safety and quality.

    PubMed

    Chen, Xi; Chen, Mo; Xu, Chenyi; Yam, Kit L

    2018-03-19

    Controlled release packaging (CRP) is an innovative technology that uses the package to release active compounds in a controlled manner to improve safety and quality for a wide range of food products during storage. This paper provides a critical review of the uniqueness, design considerations, and research gaps of CRP, with a focus on the kinetics and mechanism of active compounds releasing from the package. Literature data and practical examples are presented to illustrate how CRP controls what active compounds to release, when and how to release, how much and how fast to release, in order to improve food safety and quality.

  10. Automated Transfer Vehicle (ATV) Critical Safety Software Overview

    NASA Astrophysics Data System (ADS)

    Berthelier, D.

    2002-01-01

    The European Automated Transfer Vehicle is an unmanned transportation system designed to dock to International Space Station (ISS) and to contribute to the logistic servicing of the ISS. Concisely, ATV control is realized by a nominal flight control function (using computers, softwares, sensors, actuators). In order to cover the extreme situations where this nominal chain can not ensure safe trajectory with respect to ISS, a segregated proximity flight safety function is activated, where unsafe free drift trajectories can be encountered. This function relies notably on a segregated computer, the Monitoring and Safing Unit (MSU) ; in case of major ATV malfunction detection, ATV is then controlled by MSU software. Therefore, this software is critical because a MSU software failure could result in catastrophic consequences. This paper provides an overview both of this software functions and of the software development and validation method which is specific considering its criticality. First part of the paper describes briefly the proximity flight safety chain. Second part deals with the software functions. Indeed, MSU software is in charge of monitoring nominal computers and ATV corridors, using its own navigation algorithms, and, if an abnormal situation is detected, it is in charge of the ATV control during the Collision Avoidance Manoeuvre (CAM) consisting in an attitude controlled braking boost, followed by a Post-CAM manoeuvre : a Sun-pointed ATV attitude control during up to 24 hours on a safe trajectory. Monitoring, navigation and control algorithms principles are presented. Third part of this paper describes the development and validation process : algorithms functional studies , ADA coding and unit validations ; algorithms ADA code integration and validation on a specific non real-time MATLAB/SIMULINK simulator ; global software functional engineering phase, architectural design, unit testing, integration and validation on target computer.

  11. Preparing Students for Critical-Thinking Applications on Standardized Tests

    ERIC Educational Resources Information Center

    Hendricks, Jacquelyn Kaye

    2010-01-01

    Student performance on critical-thinking applications on standardized tests in a southwestern U.S. state has been low for several years. The purpose of this instrumental case study was to explore how one school district prepared students for critical-thinking applications on standardized tests. The study was informed by cognitivism and…

  12. Packaging Strategies for Criticality Safety for "Other" DOE Fuels in a Repository

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larry L Taylor

    2004-06-01

    Since 1998, there has been an ongoing effort to gain acceptance of U.S. Department of Energy (DOE)-owned spent nuclear fuel (SNF) in the national repository. To accomplish this goal, the fuel matrix was used as a discriminating feature to segregate fuels into nine distinct groups. From each of those groups, a characteristic fuel was selected and analyzed for criticality safety based on a proposed packaging strategy. This report identifies and quantifies the important criticality parameters for the canisterized fuels within each criticality group to: (1) demonstrate how the “other” fuels in the group are bounded by the baseline calculations ormore » (2) allow identification of individual type fuels that might require special analysis and packaging.« less

  13. Using the Job Demands-Resources model to investigate risk perception, safety climate and job satisfaction in safety critical organizations.

    PubMed

    Nielsen, Morten Birkeland; Mearns, Kathryn; Matthiesen, Stig Berge; Eid, Jarle

    2011-10-01

    Using the Job Demands-Resources model (JD-R) as a theoretical framework, this study investigated the relationship between risk perception as a job demand and psychological safety climate as a job resource with regard to job satisfaction in safety critical organizations. In line with the JD-R model, it was hypothesized that high levels of risk perception is related to low job satisfaction and that a positive perception of safety climate is related to high job satisfaction. In addition, it was hypothesized that safety climate moderates the relationship between risk perception and job satisfaction. Using a sample of Norwegian offshore workers (N = 986), all three hypotheses were supported. In summary, workers who perceived high levels of risk reported lower levels of job satisfaction, whereas this effect diminished when workers perceived their safety climate as positive. Follow-up analyses revealed that this interaction was dependent on the type of risks in question. The results of this study supports the JD-R model, and provides further evidence for relationships between safety-related concepts and work-related outcomes indicating that organizations should not only develop and implement sound safety procedures to reduce the effects of risks and hazards on workers, but can also enhance other areas of organizational life through a focus on safety. © 2011 The Authors. Scandinavian Journal of Psychology © 2011 The Scandinavian Psychological Associations.

  14. Modeling and applications in microbial food safety

    USDA-ARS?s Scientific Manuscript database

    Mathematical modeling is a scientific and systematic approach to study and describe the recurrent events or phenomena with successful application track for decades. When models are properly developed and validated, their applications may save costs and time. For the microbial food safety concerns, ...

  15. Instructional games and activities for criticality safety training

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bullard, B.; McBride, J.

    1993-01-01

    During the past several years, the Training and Management Systems Division (TMSD) staff of Oak Ridge Institute for Science and Education (ORISE) has designed and developed nuclear criticality safety (NCS) training programs that focus on high trainee involvement through the use of instructional games and activities. This paper discusses the instructional game, initial considerations for developing games, advantages and limitations of games, and how games may be used in developing and implementing NCS training. It also provides examples of the various instructional games and activities used in separate courses designed for Martin Marietta Energy Systems (MMES's) supervisors and U.S. Nuclearmore » Regulatory Commission (NRC) fuel facility inspectors.« less

  16. A sensor monitoring system for telemedicine, safety and security applications

    NASA Astrophysics Data System (ADS)

    Vlissidis, Nikolaos; Leonidas, Filippos; Giovanis, Christos; Marinos, Dimitrios; Aidinis, Konstantinos; Vassilopoulos, Christos; Pagiatakis, Gerasimos; Schmitt, Nikolaus; Pistner, Thomas; Klaue, Jirka

    2017-02-01

    A sensor system capable of medical, safety and security monitoring in avionic and other environments (e.g. homes) is examined. For application inside an aircraft cabin, the system relies on an optical cellular network that connects each seat to a server and uses a set of database applications to process data related to passengers' health, safety and security status. Health monitoring typically encompasses electrocardiogram, pulse oximetry and blood pressure, body temperature and respiration rate while safety and security monitoring is related to the standard flight attendance duties, such as cabin preparation for take-off, landing, flight in regions of turbulence, etc. In contrast to previous related works, this article focuses on the system's modules (medical and safety sensors and associated hardware), the database applications used for the overall control of the monitoring function and the potential use of the system for security applications. Further tests involving medical, safety and security sensing performed in an real A340 mock-up set-up are also described and reference is made to the possible use of the sensing system in alternative environments and applications, such as health monitoring within other means of transport (e.g. trains or small passenger sea vessels) as well as for remotely located home users, over a wired Ethernet network or the Internet.

  17. Nuclear criticality safety bounding analysis for the in-tank-precipitation (ITP) process, impacted by fissile isotopic weight fractions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bess, C.E.

    The In-Tank Precipitation process (ITP) receives High Level Waste (HLW) supernatant liquid containing radionuclides in waste processing tank 48H. Sodium tetraphenylborate, NaTPB, and monosodium titanate (MST), NaTi{sub 2}O{sub 5}H, are added for removal of radioactive Cs and Sr, respectively. In addition to removal of radio-strontium, MST will also remove plutonium and uranium. The majority of the feed solutions to ITP will come from the dissolution of supernate that had been concentrated by evaporation to a crystallized salt form, commonly referred to as saltcake. The concern for criticality safety arises from the adsorption of U and Pt onto MST. If sufficientmore » mass and optimum conditions are achieved then criticality is credible. The concentration of u and Pt from solution into the smaller volume of precipitate represents a concern for criticality. This report supplements WSRC-TR-93-171, Nuclear Criticality Safety Bounding Analysis For The In-Tank-Precipitation (ITP) Process. Criticality safety in ITP can be analyzed by two bounding conditions: (1) the minimum safe ratio of MST to fissionable material and (2) the maximum fissionable material adsorption capacity of the MST. Calculations have provided the first bounding condition and experimental analysis has established the second. This report combines these conditions with canyon facility data to evaluate the potential for criticality in the ITP process due to the adsorption of the fissionable material from solution. In addition, this report analyzes the potential impact of increased U loading onto MST. Results of this analysis demonstrate a greater safety margin for ITP operations than the previous analysis. This report further demonstrates that the potential for criticality in the ITP process due to adsorption of fissionable material by MST is not credible.« less

  18. A Novel Series Connected Batteries State of High Voltage Safety Monitor System for Electric Vehicle Application

    PubMed Central

    Jiaxi, Qiang; Lin, Yang; Jianhui, He; Qisheng, Zhou

    2013-01-01

    Batteries, as the main or assistant power source of EV (Electric Vehicle), are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS), the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application. PMID:24194677

  19. A novel series connected batteries state of high voltage safety monitor system for electric vehicle application.

    PubMed

    Jiaxi, Qiang; Lin, Yang; Jianhui, He; Qisheng, Zhou

    2013-01-01

    Batteries, as the main or assistant power source of EV (Electric Vehicle), are usually connected in series with high voltage to improve the drivability and energy efficiency. Today, more and more batteries are connected in series with high voltage, if there is any fault in high voltage system (HVS), the consequence is serious and dangerous. Therefore, it is necessary to monitor the electric parameters of HVS to ensure the high voltage safety and protect personal safety. In this study, a high voltage safety monitor system is developed to solve this critical issue. Four key electric parameters including precharge, contact resistance, insulation resistance, and remaining capacity are monitored and analyzed based on the equivalent models presented in this study. The high voltage safety controller which integrates the equivalent models and control strategy is developed. By the help of hardware-in-loop system, the equivalent models integrated in the high voltage safety controller are validated, and the online electric parameters monitor strategy is analyzed and discussed. The test results indicate that the high voltage safety monitor system designed in this paper is suitable for EV application.

  20. Connected commercial vehicles — retrofit safety device kit project : safety applications performance and functional test plan and procedure.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  1. Overview of critical risk factors in Power-Two-Wheeler safety.

    PubMed

    Vlahogianni, Eleni I; Yannis, George; Golias, John C

    2012-11-01

    Power-Two-Wheelers (PTWs) constitute a vulnerable class of road users with increased frequency and severity of accidents. The present paper focuses of the PTW accident risk factors and reviews existing literature with regard to the PTW drivers' interactions with the automobile drivers, as well as interactions with infrastructure elements and weather conditions. Several critical risk factors are revealed with different levels of influence to PTW accident likelihood and severity. A broad classification based on the magnitude and the need for further research for each risk factor is proposed. The paper concludes by discussing the importance of dealing with accident configurations, the data quality and availability, methods implemented to model risk and exposure and risk identification which are critical for a thorough understanding of the determinants of PTW safety. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Real-world aspects of the nuclear criticality safety program at the University of Tennessee-Knoxville

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bentley, C.L.; Dunn, M.E.; Goluoglu, S.

    1996-12-31

    The nuclear criticality safety (NCS) program at the University of Tennessee-Knoxville (UTK) emphasizes the {open_quotes}real world{close_quotes} in the NCS courses that are offered and also the NCS research that is conducted. Two NCS courses are offered at UTK. The first course is an introduction to the NCS field, which uses the text by Knief and includes an overview of criticality accidents that have actually happened, standards that are currently in use and being developed, and state-of-the-art computer methods and codes. The students learn the same codes, including both theory and application, that are used by most professionals in the NCSmore » field. Thus, if a student accepts a job offer in the NCS area after graduation, he or she is capable of doing productive NCS work the first day on the job. Subcritical limits, hand-calculation methods, current regulations [both U.S. Department of Energy (DOE) and U.S. Nuclear Regulatory Commission (NRC)] and current practices are also discussed in the introductory course. The second course emphasizes real world experience and is taught by five instructors with over 100 years of combined experience.« less

  3. 78 FR 18419 - Office of Hazardous Materials Safety; Delayed Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Delayed Applications AGENCY: Pipeline and Hazardous Materials Safety.... FOR FURTHER INFORMATION CONTACT: Ryan Paquet, Director, Office of Hazardous Materials Special Permits...

  4. Future Data Communication Architectures for Safety Critical Aircraft Cabin Systems

    NASA Astrophysics Data System (ADS)

    Berkhahn, Sven-Olaf

    2012-05-01

    The cabin of modern aircraft is subject to increasing demands for fast reconfiguration and hence flexibility. These demands require studies for new network architectures and technologies of the electronic cabin systems, which consider also weight and cost reductions as well as safety constraints. Two major approaches are in consideration to reduce the complex and heavy wiring harness: the usage of a so called hybrid data bus technology, which enables the common usage of the same data bus for several electronic cabin systems with different safety and security requirements and the application of wireless data transfer technologies for electronic cabin systems.

  5. A Process-Centered Tool for Evaluating Patient Safety Performance and Guiding Strategic Improvement

    DTIC Science & Technology

    2005-01-01

    next patient safety steps in individual health care organizations. The low priority given to Category 3 (Focus on patients , other customers , and...presents a patient safety applicator tool for implementing and assessing patient safety systems in health care institutions. The applicator tool consists...the survey rounds. The study addressed three research questions: 1. What critical processes should be included in health care patient safety systems

  6. 49 CFR 176.704 - Requirements relating to transport indices and criticality safety indices.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Requirements relating to transport indices and... Requirements relating to transport indices and criticality safety indices. (a) The sum of the transport indices..., transport and unloading are to be supervised by persons qualified in the transport of radioactive material...

  7. 49 CFR 176.704 - Requirements relating to transport indices and criticality safety indices.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Requirements relating to transport indices and... Requirements relating to transport indices and criticality safety indices. (a) The sum of the transport indices..., transport and unloading are to be supervised by persons qualified in the transport of radioactive material...

  8. Nuclear criticality safety evaluation of the passage of decontaminated salt solution from the ITP filters into tank 50H for interim storage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hobbs, D.T.; Davis, J.R.

    This report assesses the nuclear criticality safety associated with the decontaminated salt solution after passing through the In-Tank Precipitation (ITP) filters, through the stripper columns and into Tank 50H for interim storage until transfer to the Saltstone facility. The criticality safety basis for the ITP process is documented. Criticality safety in the ITP filtrate has been analyzed under normal and process upset conditions. This report evaluates the potential for criticality due to the precipitation or crystallization of fissionable material from solution and an ITP process filter failure in which insoluble material carryover from salt dissolution is present. It is concludedmore » that no single inadvertent error will cause criticality and that the process will remain subcritical under normal and credible abnormal conditions.« less

  9. Safety Psychology Applicating on Coal Mine Safety Management Based on Information System

    NASA Astrophysics Data System (ADS)

    Hou, Baoyue; Chen, Fei

    In recent years, with the increase of intensity of coal mining, a great number of major accidents happen frequently, the reason mostly due to human factors, but human's unsafely behavior are affected by insecurity mental control. In order to reduce accidents, and to improve safety management, with the help of application security psychology, we analyse the cause of insecurity psychological factors from human perception, from personality development, from motivation incentive, from reward and punishment mechanism, and from security aspects of mental training , and put forward countermeasures to promote coal mine safety production,and to provide information for coal mining to improve the level of safety management.

  10. Electron beam processing of fresh produce - A critical review

    NASA Astrophysics Data System (ADS)

    Pillai, Suresh D.; Shayanfar, Shima

    2018-02-01

    To meet the increasing global demand for fresh produce, robust processing methods that ensures both the safety and quality of fresh produce are needed. Since fresh produce cannot withstand thermal processing conditions, most of common safety interventions used in other foods are ineffective. Electron beam (eBeam) is a non-thermal technology that can be used to extend the shelf life and ensure the microbiological safety of fresh produce. There have been studies documenting the application of eBeam to ensure both safety and quality in fresh produce, however, there are still unexplored areas that still need further research. This is a critical review on the current literature on the application of eBeam technology for fresh produce.

  11. Systems modeling and simulation applications for critical care medicine

    PubMed Central

    2012-01-01

    Critical care delivery is a complex, expensive, error prone, medical specialty and remains the focal point of major improvement efforts in healthcare delivery. Various modeling and simulation techniques offer unique opportunities to better understand the interactions between clinical physiology and care delivery. The novel insights gained from the systems perspective can then be used to develop and test new treatment strategies and make critical care delivery more efficient and effective. However, modeling and simulation applications in critical care remain underutilized. This article provides an overview of major computer-based simulation techniques as applied to critical care medicine. We provide three application examples of different simulation techniques, including a) pathophysiological model of acute lung injury, b) process modeling of critical care delivery, and c) an agent-based model to study interaction between pathophysiology and healthcare delivery. Finally, we identify certain challenges to, and opportunities for, future research in the area. PMID:22703718

  12. Safety design considerations for lithium batteries in CF applications

    NASA Astrophysics Data System (ADS)

    Moroz, W. J.

    1981-02-01

    Lithium-sulphur dioxide (Li-SO2) primary cells are being introduced as power supplies into Canadian Forces applications where advantage can be taken of their high energy density characteristics and low temperature capabilities. For safety reasons the high energy capabilities of these cells must be protected against the possibility of accidental abuse. DREO has investigated and identified a number of operational problem areas associated with Li-SO2 systems. Safety design considerations are proposed for three CF applications; the PRC 515 Radio Set/Radar Transponder SST-181X applications and the AN/PRQ-501 Personal Locater Beacon.

  13. The Evaluation of the Safety Benefits of Combined Passive and On-Board Active Safety Applications

    PubMed Central

    Page, Yves; Cuny, Sophie; Zangmeister, Tobias; Kreiss, Jens-Peter; Hermitte, Thierry

    2009-01-01

    One of the objectives of the European TRACE project (TRaffic Accident Causation in Europe, 2006–2008) was to estimate the proportion of injury accidents that could be avoided and/or the proportion of injury accidents where the severity could be mitigated for on-the-market safety applications, if 100 % of the car fleet would be equipped with them. We have selected for evaluation the Electronic Stability Control (ESC) and the Emergency Brake Assist (EBA) applications. As for passive safety systems, recent cars are designed to offer overall safety protection. Car structure, load limiters, front airbags, side airbags, knee airbags, pretensioners, padding and non aggressive structures in the door panel, the dashboard, the windshield, the seats, and the head rest also contribute to applying more protection. The whole safety package is very difficult to evaluate separately, one element independently segmented from the others. We decided to consider evaluating the effectivenessof the whole passive safety package, This package,, for the sake of simplicity, was the number of stars awarded at the Euro NCAP testing. The challenges were to compare the effectiveness of some safety configuration SC I, with the effectiveness of a different safety configuration SC II. A safety configuration is understood as a package of safety functions. Ten comparisons have been carried out such as the evaluation of the safety benefit of a fifth star given that the car has four stars and an EBA. The main outcome of this analysis is that any addition of a passive or active safety function selected in this analysis is producing increased safety benefits. For example, if all cars were five stars fitted with EBA and ESC, instead of four stars without ESC and EBA, injury accidents would be reduced by 47.2% for severe injuries and 69.5% for fatal injuries. PMID:20184838

  14. Generalized implementation of software safety policies

    NASA Technical Reports Server (NTRS)

    Knight, John C.; Wika, Kevin G.

    1994-01-01

    As part of a research program in the engineering of software for safety-critical systems, we are performing two case studies. The first case study, which is well underway, is a safety-critical medical application. The second, which is just starting, is a digital control system for a nuclear research reactor. Our goal is to use these case studies to permit us to obtain a better understanding of the issues facing developers of safety-critical systems, and to provide a vehicle for the assessment of research ideas. The case studies are not based on the analysis of existing software development by others. Instead, we are attempting to create software for new and novel systems in a process that ultimately will involve all phases of the software lifecycle. In this abstract, we summarize our results to date in a small part of this project, namely the determination and classification of policies related to software safety that must be enforced to ensure safe operation. We hypothesize that this classification will permit a general approach to the implementation of a policy enforcement mechanism.

  15. Determination of Slope Safety Factor with Analytical Solution and Searching Critical Slip Surface with Genetic-Traversal Random Method

    PubMed Central

    2014-01-01

    In the current practice, to determine the safety factor of a slope with two-dimensional circular potential failure surface, one of the searching methods for the critical slip surface is Genetic Algorithm (GA), while the method to calculate the slope safety factor is Fellenius' slices method. However GA needs to be validated with more numeric tests, while Fellenius' slices method is just an approximate method like finite element method. This paper proposed a new method to determine the minimum slope safety factor which is the determination of slope safety factor with analytical solution and searching critical slip surface with Genetic-Traversal Random Method. The analytical solution is more accurate than Fellenius' slices method. The Genetic-Traversal Random Method uses random pick to utilize mutation. A computer automatic search program is developed for the Genetic-Traversal Random Method. After comparison with other methods like slope/w software, results indicate that the Genetic-Traversal Random Search Method can give very low safety factor which is about half of the other methods. However the obtained minimum safety factor with Genetic-Traversal Random Search Method is very close to the lower bound solutions of slope safety factor given by the Ansys software. PMID:24782679

  16. 75 FR 4305 - Regulatory Guidance Concerning the Applicability of the Federal Motor Carrier Safety Regulations...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... of drivers conducting real-world revenue operations. \\1\\ This report is available at FMCSA's Research... odds ratio of 23.2. This means that the odds of being involved in a safety-critical event is 23.2 times... preceding a safety-critical event. At 55 mph (or 80.7 feet per second), this equates to a driver traveling...

  17. Criticality safety strategy and analysis summary for the fuel cycle facility electrorefiner at Argonne National Laboratory West

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mariani, R.D.; Benedict, R.W.; Lell, R.M.

    1996-05-01

    As part of the termination activities of Experimental Breeder Reactor II (EBR-II) at Argonne National Laboratory (ANL) West, the spent metallic fuel from EBR-II will be treated in the fuel cycle facility (FCF). A key component of the spent-fuel treatment process in the FCF is the electrorefiner (ER) in which the actinide metals are separated from the active metal fission products and the reactive bond sodium. In the electrorefining process, the metal fuel is anodically dissolved into a high-temperature molten salt, and refined uranium or uranium/plutonium products are deposited at cathodes. The criticality safety strategy and analysis for the ANLmore » West FCF ER is summarized. The FCF ER operations and processes formed the basis for evaluating criticality safety and control during actinide metal fuel refining. To show criticality safety for the FCF ER, the reference operating conditions for the ER had to be defined. Normal operating envelopes (NOEs) were then defined to bracket the important operating conditions. To keep the operating conditions within their NOEs, process controls were identified that can be used to regulate the actinide forms and content within the ER. A series of operational checks were developed for each operation that will verify the extent or success of an operation. The criticality analysis considered the ER operating conditions at their NOE values as the point of departure for credible and incredible failure modes. As a result of the analysis, FCF ER operations were found to be safe with respect to criticality.« less

  18. 7T: Physics, safety, and potential clinical applications.

    PubMed

    Kraff, Oliver; Quick, Harald H

    2017-12-01

    With more than 60 installed magnetic resonance imaging (MRI) systems worldwide operating at a magnetic field strength of 7T or higher, ultrahigh-field (UHF) MRI has been established as a platform for clinically oriented research in recent years. Profound technical and methodological developments have helped overcome the inherent physical challenges of UHF radiofrequency (RF) signal homogenization in the human body. The ongoing development of dedicated RF coil arrays was pivotal in realizing UHF body MRI, beyond mere brain imaging applications. Another precondition to clinical application of 7T MRI is the safety testing of implants and the establishment of safety concepts. Against this backdrop, 7T MRI and MR spectroscopy (MRS) recently have demonstrated capabilities and potentials for clinical diagnostics in a variety of studies. This article provides an overview of the immanent physical challenges of 7T UHF MRI and discusses recent technical solutions and safety concepts. Furthermore, recent clinically oriented studies are highlighted that span a broad application spectrum from 7T UHF brain to body MRI. 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1573-1589. © 2017 International Society for Magnetic Resonance in Medicine.

  19. Critical Incident Stress Management (CISM) in complex systems: cultural adaptation and safety impacts in healthcare.

    PubMed

    Müller-Leonhardt, Alice; Mitchell, Shannon G; Vogt, Joachim; Schürmann, Tim

    2014-07-01

    In complex systems, such as hospitals or air traffic control operations, critical incidents (CIs) are unavoidable. These incidents can not only become critical for victims but also for professionals working at the "sharp end" who may have to deal with critical incident stress (CIS) reactions that may be severe and impede emotional, physical, cognitive and social functioning. These CIS reactions may occur not only under exceptional conditions but also during every-day work and become an important safety issue. In contrast to air traffic management (ATM) operations in Europe, which have readily adopted critical incident stress management (CISM), most hospitals have not yet implemented comprehensive peer support programs. This survey was conducted in 2010 at the only European general hospital setting which implemented CISM program since 2004. The aim of the article is to describe possible contribution of CISM in hospital settings framed from the perspective of organizational safety and individual health for healthcare professionals. Findings affirm that daily work related incidents also can become critical for healthcare professionals. Program efficiency appears to be influenced by the professional culture, as well as organizational structure and policies. Overall, findings demonstrate that the adaptation of the CISM program in general hospitals takes time but, once established, it may serve as a mechanism for changing professional culture, thereby permitting the framing of even small incidents or near misses as an opportunity to provide valuable feedback to the system. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Risk assessment of component failure modes and human errors using a new FMECA approach: application in the safety analysis of HDR brachytherapy.

    PubMed

    Giardina, M; Castiglia, F; Tomarchio, E

    2014-12-01

    Failure mode, effects and criticality analysis (FMECA) is a safety technique extensively used in many different industrial fields to identify and prevent potential failures. In the application of traditional FMECA, the risk priority number (RPN) is determined to rank the failure modes; however, the method has been criticised for having several weaknesses. Moreover, it is unable to adequately deal with human errors or negligence. In this paper, a new versatile fuzzy rule-based assessment model is proposed to evaluate the RPN index to rank both component failure and human error. The proposed methodology is applied to potential radiological over-exposure of patients during high-dose-rate brachytherapy treatments. The critical analysis of the results can provide recommendations and suggestions regarding safety provisions for the equipment and procedures required to reduce the occurrence of accidental events.

  1. Does the concept of safety culture help or hinder systems thinking in safety?

    PubMed

    Reiman, Teemu; Rollenhagen, Carl

    2014-07-01

    The concept of safety culture has become established in safety management applications in all major safety-critical domains. The idea that safety culture somehow represents a "systemic view" on safety is seldom explicitly spoken out, but nevertheless seem to linger behind many safety culture discourses. However, in this paper we argue that the "new" contribution to safety management from safety culture never really became integrated with classical engineering principles and concepts. This integration would have been necessary for the development of a more genuine systems-oriented view on safety; e.g. a conception of safety in which human, technological, organisational and cultural factors are understood as mutually interacting elements. Without of this integration, researchers and the users of the various tools and methods associated with safety culture have sometimes fostered a belief that "safety culture" in fact represents such a systemic view about safety. This belief is, however, not backed up by theoretical or empirical evidence. It is true that safety culture, at least in some sense, represents a holistic term-a totality of factors that include human, organisational and technological aspects. However, the departure for such safety culture models is still human and organisational factors rather than technology (or safety) itself. The aim of this paper is to critically review the various uses of the concept of safety culture as representing a systemic view on safety. The article will take a look at the concepts of culture and safety culture based on previous studies, and outlines in more detail the theoretical challenges in safety culture as a systems concept. The paper also presents recommendations on how to make safety culture more systemic. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Fault tree applications within the safety program of Idaho Nuclear Corporation

    NASA Technical Reports Server (NTRS)

    Vesely, W. E.

    1971-01-01

    Computerized fault tree analyses are used to obtain both qualitative and quantitative information about the safety and reliability of an electrical control system that shuts the reactor down when certain safety criteria are exceeded, in the design of a nuclear plant protection system, and in an investigation of a backup emergency system for reactor shutdown. The fault tree yields the modes by which the system failure or accident will occur, the most critical failure or accident causing areas, detailed failure probabilities, and the response of safety or reliability to design modifications and maintenance schemes.

  3. Querying Safety Cases

    NASA Technical Reports Server (NTRS)

    Denney, Ewen W.; Naylor, Dwight; Pai, Ganesh

    2014-01-01

    Querying a safety case to show how the various stakeholders' concerns about system safety are addressed has been put forth as one of the benefits of argument-based assurance (in a recent study by the Health Foundation, UK, which reviewed the use of safety cases in safety-critical industries). However, neither the literature nor current practice offer much guidance on querying mechanisms appropriate for, or available within, a safety case paradigm. This paper presents a preliminary approach that uses a formal basis for querying safety cases, specifically Goal Structuring Notation (GSN) argument structures. Our approach semantically enriches GSN arguments with domain-specific metadata that the query language leverages, along with its inherent structure, to produce views. We have implemented the approach in our toolset AdvoCATE, and illustrate it by application to a fragment of the safety argument for an Unmanned Aircraft System (UAS) being developed at NASA Ames. We also discuss the potential practical utility of our query mechanism within the context of the existing framework for UAS safety assurance.

  4. Fault Injection Validation of a Safety-Critical TMR Sysem

    NASA Astrophysics Data System (ADS)

    Irrera, Ivano; Madeira, Henrique; Zentai, Andras; Hergovics, Beata

    2016-08-01

    Digital systems and their software are the core technology for controlling and monitoring industrial systems in practically all activity domains. Functional safety standards such as the European standard EN 50128 for railway applications define the procedures and technical requirements for the development of software for railway control and protection systems. The validation of such systems is a highly demanding task. In this paper we discuss the use of fault injection techniques, which have been used extensively in several domains, particularly in the space domain, to complement the traditional procedures to validate a SIL (Safety Integrity Level) 4 system for railway signalling, implementing a TMR (Triple Modular Redundancy) architecture. The fault injection tool is based on JTAG technology. The results of our injection campaign showed a high degree of tolerance to most of the injected faults, but several cases of unexpected behaviour have also been observed, helping understanding worst-case scenarios.

  5. 29 CFR 500.102 - Applicability of vehicle safety standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 3 2011-07-01 2011-07-01 false Applicability of vehicle safety standards. 500.102 Section 500.102 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR REGULATIONS MIGRANT AND SEASONAL AGRICULTURAL WORKER PROTECTION Motor Vehicle Safety and Insurance for Transportation of Migrant and Seasonal...

  6. Application of hazard analysis and critical control point methodology and risk-based grading to consumer food safety surveys.

    PubMed

    Røssvoll, Elin Halbach; Ueland, Øydis; Hagtvedt, Therese; Jacobsen, Eivind; Lavik, Randi; Langsrud, Solveig

    2012-09-01

    Traditionally, consumer food safety survey responses have been classified as either "right" or "wrong" and food handling practices that are associated with high risk of infection have been treated in the same way as practices with lower risks. In this study, a risk-based method for consumer food safety surveys has been developed, and HACCP (hazard analysis and critical control point) methodology was used for selecting relevant questions. We conducted a nationally representative Web-based survey (n = 2,008), and to fit the self-reported answers we adjusted a risk-based grading system originally developed for observational studies. The results of the survey were analyzed both with the traditional "right" and "wrong" classification and with the risk-based grading system. The results using the two methods were very different. Only 5 of the 10 most frequent food handling violations were among the 10 practices associated with the highest risk. These 10 practices dealt with different aspects of heat treatment (lacking or insufficient), whereas the majority of the most frequent violations involved storing food at room temperature for too long. Use of the risk-based grading system for survey responses gave a more realistic picture of risks associated with domestic food handling practices. The method highlighted important violations and minor errors, which are performed by most people and are not associated with significant risk. Surveys built on a HACCP-based approach with risk-based grading will contribute to a better understanding of domestic food handling practices and will be of great value for targeted information and educational activities.

  7. Mission and Safety Critical (MASC) plans for the MASC Kernel simulation

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This report discusses a prototype for Mission and Safety Critical (MASC) kernel simulation which explains the intended approach and how the simulation will be used. Smalltalk is chosen for the simulation because of usefulness in quickly building working models of the systems and its object-oriented approach to software. A scenario is also introduced to give details about how the simulation works. The eventual system will be a fully object-oriented one implemented in Ada via Dragoon. To implement the simulation, a scenario using elements typical of those in the Space Station, was created.

  8. Overview of Therapeutic Ultrasound Applications and Safety Considerations

    PubMed Central

    Miller, Douglas; Smith, Nadine; Bailey, Michael; Czarnota, Gregory; Hynynen, Kullervo; Makin, Inder

    2013-01-01

    Summary Applications of ultrasound in medicine for therapeutic purposes have been an accepted and beneficial use of ultrasonic biological effects for many years. Low power ultrasound of about 1 MHz frequency has been widely applied since the 1950s for physical therapy in conditions such as tendinitis or bursitis. In the 1980s, high pressure-amplitude shockwaves came into use for mechanically resolving kidney stones, and “lithotripsy” rapidly replaced surgery as the most frequent treatment choice. The use of ultrasonic energy for therapy continues to expand, and approved applications now include uterine fibroid ablation, cataract removal (phacoemulsification), surgical tissue cutting and hemostasis, transdermal drug delivery, and bone fracture healing, among others. Undesirable bioeffects can occur including burns for thermal-based therapies and significant hemorrhage for mechanical-based therapies (e. g. lithotripsy). In all these therapeutic applications for bioeffects of ultrasound, standardization, ultrasound dosimetry, benefits assurance and side-effects risk minimization must be carefully considered in order to insure an optimal benefit to risk ratio for the patient. Therapeutic ultrasound typically has well-defined benefits and risks, and therefore presents a tractable safety problem to the clinician. However, safety information can be scattered, confusing or subject to commercial conflict of interest. Of paramount importance for managing this problem is the communication of practical safety information by authoritative groups, such as the AIUM, to the medical ultrasound community. In this overview, the Bioeffects Committee outlines the wide range of therapeutic ultrasound methods, which are in clinical use or under study, and provides general guidance for assuring therapeutic ultrasound safety. PMID:22441920

  9. 75 FR 52392 - Office Of Hazardous Materials Safety; Notice of Application for Special Permits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-25

    ... DEPARTMENT OF TRANSPORTATION Pipeline And Hazardous Materials Safety Administration Office Of Hazardous Materials Safety; Notice of Application for Special Permits AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: List of applications for special permits. SUMMARY: In...

  10. Nanotechnology in food science: Functionality, applicability, and safety assessment.

    PubMed

    He, Xiaojia; Hwang, Huey-Min

    2016-10-01

    Rapid development of nanotechnology is expected to transform many areas of food science and food industry with increasing investment and market share. In this article, current applications of nanotechnology in food systems are briefly reviewed. Functionality and applicability of food-related nanotechnology are highlighted in order to provide a comprehensive view on the development and safety assessment of nanotechnology in the food industry. While food nanotechnology offers great potential benefits, there are emerging concerns arising from its novel physicochemical properties. Therefore, the safety concerns and regulatory policies on its manufacturing, processing, packaging, and consumption are briefly addressed. At the end of this article, the perspectives of nanotechnology in active and intelligent packaging applications are highlighted. Copyright © 2016. Published by Elsevier B.V.

  11. Validation and Verification of Future Integrated Safety-Critical Systems Operating under Off-Nominal Conditions

    NASA Technical Reports Server (NTRS)

    Belcastro, Christine M.

    2010-01-01

    Loss of control remains one of the largest contributors to aircraft fatal accidents worldwide. Aircraft loss-of-control accidents are highly complex in that they can result from numerous causal and contributing factors acting alone or (more often) in combination. Hence, there is no single intervention strategy to prevent these accidents and reducing them will require a holistic integrated intervention capability. Future onboard integrated system technologies developed for preventing loss of vehicle control accidents must be able to assure safe operation under the associated off-nominal conditions. The transition of these technologies into the commercial fleet will require their extensive validation and verification (V and V) and ultimate certification. The V and V of complex integrated systems poses major nontrivial technical challenges particularly for safety-critical operation under highly off-nominal conditions associated with aircraft loss-of-control events. This paper summarizes the V and V problem and presents a proposed process that could be applied to complex integrated safety-critical systems developed for preventing aircraft loss-of-control accidents. A summary of recent research accomplishments in this effort is also provided.

  12. 78 FR 37653 - Notice of Fiscal Year (FY) 2014 Safety Grants and Solicitation for Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-21

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration Notice of Fiscal Year (FY) 2014 Safety Grants and Solicitation for Applications AGENCY: Federal Motor Carrier Safety.... SUMMARY: FMCSA announces the availability of FY 2014 safety grant opportunities and application due dates...

  13. Extracting Information from Narratives: An Application to Aviation Safety Reports

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Posse, Christian; Matzke, Brett D.; Anderson, Catherine M.

    2005-05-12

    Aviation safety reports are the best available source of information about why a flight incident happened. However, stream of consciousness permeates the narratives making difficult the automation of the information extraction task. We propose an approach and infrastructure based on a common pattern specification language to capture relevant information via normalized template expression matching in context. Template expression matching handles variants of multi-word expressions. Normalization improves the likelihood of correct hits by standardizing and cleaning the vocabulary used in narratives. Checking for the presence of negative modifiers in the proximity of a potential hit reduces the chance of false hits.more » We present the above approach in the context of a specific application, which is the extraction of human performance factors from NASA ASRS reports. While knowledge infusion from experts plays a critical role during the learning phase, early results show that in a production mode, the automated process provides information that is consistent with analyses by human subjects.« less

  14. NASA's Software Safety Standard

    NASA Technical Reports Server (NTRS)

    Ramsay, Christopher M.

    2007-01-01

    NASA relies more and more on software to control, monitor, and verify its safety critical systems, facilities and operations. Since the 1960's there has hardly been a spacecraft launched that does not have a computer on board that will provide command and control services. There have been recent incidents where software has played a role in high-profile mission failures and hazardous incidents. For example, the Mars Orbiter, Mars Polar Lander, the DART (Demonstration of Autonomous Rendezvous Technology), and MER (Mars Exploration Rover) Spirit anomalies were all caused or contributed to by software. The Mission Control Centers for the Shuttle, ISS, and unmanned programs are highly dependant on software for data displays, analysis, and mission planning. Despite this growing dependence on software control and monitoring, there has been little to no consistent application of software safety practices and methodology to NASA's projects with safety critical software. Meanwhile, academia and private industry have been stepping forward with procedures and standards for safety critical systems and software, for example Dr. Nancy Leveson's book Safeware: System Safety and Computers. The NASA Software Safety Standard, originally published in 1997, was widely ignored due to its complexity and poor organization. It also focused on concepts rather than definite procedural requirements organized around a software project lifecycle. Led by NASA Headquarters Office of Safety and Mission Assurance, the NASA Software Safety Standard has recently undergone a significant update. This new standard provides the procedures and guidelines for evaluating a project for safety criticality and then lays out the minimum project lifecycle requirements to assure the software is created, operated, and maintained in the safest possible manner. This update of the standard clearly delineates the minimum set of software safety requirements for a project without detailing the implementation for those

  15. Critical Geragogy and Foreign Language Learning: An Exploratory Application

    ERIC Educational Resources Information Center

    Ramírez Gómez, Danya

    2016-01-01

    This article proposes an exploratory application of the principles of critical geragogy (Formosa, 2002, 2011, 2012) to foreign language (FL) education (i.e., L2 learning in the L1 community). Critical geragogy is an educational, practical framework intended to empower older adults and lead them to emancipate from age strictures (Glendenning &…

  16. Critical roles of orthopaedic surgeon leadership in healthcare systems to improve orthopaedic surgical patient safety.

    PubMed

    Kuo, Calvin C; Robb, William J

    2013-06-01

    The prevention of medical and surgical harm remains an important public health problem despite increased awareness and implementation of safety programs. Successful introduction and maintenance of surgical safety programs require both surgeon leadership and collaborative surgeon-hospital alignment. Documentation of success of such surgical safety programs in orthopaedic practice is limited. We describe the scope of orthopaedic surgical patient safety issues, define critical elements of orthopaedic surgical safety, and outline leadership roles for orthopaedic surgeons needed to establish and sustain a culture of safety in contemporary healthcare systems. We identified the most common causes of preventable surgical harm based on adverse and sentinel surgical events reported to The Joint Commission. A comprehensive literature review through a MEDLINE(®) database search (January 1982 through April 2012) to identify pertinent orthopaedic surgical safety articles found 14 articles. Where gaps in orthopaedic literature were identified, the review was supplemented by 22 nonorthopaedic surgical references. Our final review included 36 articles. Six important surgical safety program elements needed to eliminate preventable surgical harm were identified: (1) effective surgical team communication, (2) proper informed consent, (3) implementation and regular use of surgical checklists, (4) proper surgical site/procedure identification, (5) reduction of surgical team distractions, and (6) routine surgical data collection and analysis to improve the safety and quality of surgical patient care. Successful surgical safety programs require a culture of safety supported by all six key surgical safety program elements, active surgeon champions, and collaborative hospital and/or administrative support designed to enhance surgical safety and improve surgical patient outcomes. Further research measuring improvements from such surgical safety systems in orthopaedic care is needed.

  17. Transit safety retrofit package development : applications requirements document.

    DOT National Transportation Integrated Search

    2014-05-01

    This Application Requirements Document for the Transit Safety Retrofit Package (TRP) Development captures the system, hardware and software requirements towards fulfilling the technical objectives stated within the contract. To achieve the objective ...

  18. Extended time-to-collision measures for road traffic safety assessment.

    PubMed

    Minderhoud, M M; Bovy, P H

    2001-01-01

    This article describes two new safety indicators based on the time-to-collision notion suitable for comparative road traffic safety analyses. Such safety indicators can be applied in the comparison of a do-nothing case with an adapted situation, e.g. the introduction of intelligent driver support systems. In contrast to the classical time-to-collision value, measured at a cross section, the improved safety indicators use vehicle trajectories collected over a specific time horizon for a certain roadway segment to calculate the overall safety indicator value. Vehicle-specific indicator values as well as safety-critical probabilities can easily be determined from the developed safety measures. Application of the derived safety indicators is demonstrated for the assessment of the potential safety impacts of driver support systems from which it appears that some Autonomous Intelligent Cruise Control (AICC) designs are more safety-critical than the reference case without these systems. It is suggested that the indicator threshold value to be applied in the safety assessment has to be adapted when advanced AICC-systems with safe characteristics are introduced.

  19. The Integrated Safety-Critical Advanced Avionics Communication and Control (ISAACC) System Concept: Infrastructure for ISHM

    NASA Technical Reports Server (NTRS)

    Gwaltney, David A.; Briscoe, Jeri M.

    2005-01-01

    Integrated System Health Management (ISHM) architectures for spacecraft will include hard real-time, critical subsystems and soft real-time monitoring subsystems. Interaction between these subsystems will be necessary and an architecture supporting multiple criticality levels will be required. Demonstration hardware for the Integrated Safety-Critical Advanced Avionics Communication & Control (ISAACC) system has been developed at NASA Marshall Space Flight Center. It is a modular system using a commercially available time-triggered protocol, ?Tp/C, that supports hard real-time distributed control systems independent of the data transmission medium. The protocol is implemented in hardware and provides guaranteed low-latency messaging with inherent fault-tolerance and fault-containment. Interoperability between modules and systems of modules using the TTP/C is guaranteed through definition of messages and the precise message schedule implemented by the master-less Time Division Multiple Access (TDMA) communications protocol. "Plug-and-play" capability for sensors and actuators provides automatically configurable modules supporting sensor recalibration and control algorithm re-tuning without software modification. Modular components of controlled physical system(s) critical to control algorithm tuning, such as pumps or valve components in an engine, can be replaced or upgraded as "plug and play" components without modification to the ISAACC module hardware or software. ISAACC modules can communicate with other vehicle subsystems through time-triggered protocols or other communications protocols implemented over Ethernet, MIL-STD- 1553 and RS-485/422. Other communication bus physical layers and protocols can be included as required. In this way, the ISAACC modules can be part of a system-of-systems in a vehicle with multi-tier subsystems of varying criticality. The goal of the ISAACC architecture development is control and monitoring of safety critical systems of a

  20. Modelling safety of multistate systems with ageing components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kołowrocki, Krzysztof; Soszyńska-Budny, Joanna

    An innovative approach to safety analysis of multistate ageing systems is presented. Basic notions of the ageing multistate systems safety analysis are introduced. The system components and the system multistate safety functions are defined. The mean values and variances of the multistate systems lifetimes in the safety state subsets and the mean values of their lifetimes in the particular safety states are defined. The multi-state system risk function and the moment of exceeding by the system the critical safety state are introduced. Applications of the proposed multistate system safety models to the evaluation and prediction of the safty characteristics ofmore » the consecutive “m out of n: F” is presented as well.« less

  1. Safety Arguments for Next Generation, Location Aware Computing

    NASA Technical Reports Server (NTRS)

    Johnson, C. W.; Holloway, C. M.

    2010-01-01

    Concerns over accuracy, availability, integrity, and continuity have limited the integration of Global Positioning System (GPS) and Global Navigation Satellite System (GLONASS) for safety-critical applications. More recent augmentation systems, such as the European Geostationary Navigation Overlay Service (EGNOS) and the North American Wide Area Augmentation System (WAAS) have begun to address these concerns. Augmentation architectures build on the existing GPS/GLONASS infrastructures to support location based services in Safety of Life (SoL) applications. Much of the technical development has been directed by air traffic management requirements, in anticipation of the more extensive support to be offered by GPS III and Galileo. WAAS has already been approved to provide vertical guidance for aviation applications. During the next twelve months, the full certification of EGNOS for SoL applications is expected. This paper discusses similarities and differences between the safety assessment techniques used in Europe and North America.

  2. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2013-01-01 2013-01-01 false Contents of applications; technical information in final...

  3. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2012-01-01 2012-01-01 false Contents of applications; technical information in final...

  4. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2014-01-01 2014-01-01 false Contents of applications; technical information in final...

  5. 10 CFR 52.157 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...; technical information in final safety analysis report. The application must contain a final safety analysis...) Information sufficient to demonstrate compliance with the applicable requirements regarding testing, analysis... 10 Energy 2 2011-01-01 2011-01-01 false Contents of applications; technical information in final...

  6. Development of a nursing handoff tool: a web-based application to enhance patient safety.

    PubMed

    Goldsmith, Denise; Boomhower, Marc; Lancaster, Diane R; Antonelli, Mary; Kenyon, Mary Anne Murphy; Benoit, Angela; Chang, Frank; Dykes, Patricia C

    2010-11-13

    Dynamic and complex clinical environments present many challenges for effective communication among health care providers. The omission of accurate, timely, easily accessible vital information by health care providers significantly increases risk of patient harm and can have devastating consequences for patient care. An effective nursing handoff supports the standardized transfer of accurate, timely, critical patient information, as well as continuity of care and treatment, resulting in enhanced patient safety. The Brigham and Women's/Faulkner Hospital Healthcare Information Technology Innovation Program (HIP) is supporting the development of a web based nursing handoff tool (NHT). The goal of this project is to develop a "proof of concept" handoff application to be evaluated by nurses on the inpatient intermediate care units. The handoff tool would enable nurses to use existing knowledge of evidence-based handoff methodology in their everyday practice to improve patient care and safety. In this paper, we discuss the results of nursing focus groups designed to identify the current state of handoff practice as well as the functional and data element requirements of a web based Nursing Handoff Tool (NHT).

  7. Food safety and nutritional quality for the prevention of non communicable diseases: the Nutrient, hazard Analysis and Critical Control Point process (NACCP).

    PubMed

    Di Renzo, Laura; Colica, Carmen; Carraro, Alberto; Cenci Goga, Beniamino; Marsella, Luigi Tonino; Botta, Roberto; Colombo, Maria Laura; Gratteri, Santo; Chang, Ting Fa Margherita; Droli, Maurizio; Sarlo, Francesca; De Lorenzo, Antonino

    2015-04-23

    The important role of food and nutrition in public health is being increasingly recognized as crucial for its potential impact on health-related quality of life and the economy, both at the societal and individual levels. The prevalence of non-communicable diseases calls for a reformulation of our view of food. The Hazard Analysis and Critical Control Point (HACCP) system, first implemented in the EU with the Directive 43/93/CEE, later replaced by Regulation CE 178/2002 and Regulation CE 852/2004, is the internationally agreed approach for food safety control. Our aim is to develop a new procedure for the assessment of the Nutrient, hazard Analysis and Critical Control Point (NACCP) process, for total quality management (TMQ), and optimize nutritional levels. NACCP was based on four general principles: i) guarantee of health maintenance; ii) evaluate and assure the nutritional quality of food and TMQ; iii) give correct information to the consumers; iv) ensure an ethical profit. There are three stages for the application of the NACCP process: 1) application of NACCP for quality principles; 2) application of NACCP for health principals; 3) implementation of the NACCP process. The actions are: 1) identification of nutritional markers, which must remain intact throughout the food supply chain; 2) identification of critical control points which must monitored in order to minimize the likelihood of a reduction in quality; 3) establishment of critical limits to maintain adequate levels of nutrient; 4) establishment, and implementation of effective monitoring procedures of critical control points; 5) establishment of corrective actions; 6) identification of metabolic biomarkers; 7) evaluation of the effects of food intake, through the application of specific clinical trials; 8) establishment of procedures for consumer information; 9) implementation of the Health claim Regulation EU 1924/2006; 10) starting a training program. We calculate the risk assessment as follows

  8. 76 FR 51058 - Petitions for Modification of Application of Existing Mandatory Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-17

    ... CFR part 48 training plan to the Metal/ Nonmetal Safety and Health District Manager. In addition to... DEPARTMENT OF LABOR Mine Safety and Health Administration Petitions for Modification of Application of Existing Mandatory Safety Standards AGENCY: Mine Safety and Health Administration, Labor...

  9. The Ultimate Factor of Safety for Aircraft and Spacecraft Its History, Applications and Misconceptions

    NASA Technical Reports Server (NTRS)

    Zipay, John J.; Modlin, C. Thomas, Jr.; Larsen, Curtis E.

    2016-01-01

    The ultimate factor of safety (FOSULT) concept used in aircraft and spacecraft has evolved over many decades. Currently an FOSULT 1.5 is the FAR-mandated value for aircraft while an FOSULT of 1.4 has been used in various spacecraft. This paper was motivated by the desire to concisely explain the origins, proper interpretation and application of the ultimate factor of safety concept, since the authors have seen throughout their careers many misconceptions and incorrect applications of this concept. The history of the ultimate factor of safety concept is briefly summarized, the proper application of the factor of safety in aircraft design, structural analysis and operations is covered in detail, examples of limit load exceedance in aircraft and spacecraft are discussed, the evolution of the 1.4 FOSULT for spacecraft is described and some misconceptions regarding the ultimate factor of safety concept are addressed. It is hoped that this paper can be a summary resource for engineers to understand the origin, purpose and proper application of the ultimate factor of safety.

  10. An Anesthesia Preinduction Checklist to Improve Information Exchange, Knowledge of Critical Information, Perception of Safety, and Possibly Perception of Teamwork in Anesthesia Teams.

    PubMed

    Tscholl, David W; Weiss, Mona; Kolbe, Michaela; Staender, Sven; Seifert, Burkhardt; Landert, Daniel; Grande, Bastian; Spahn, Donat R; Noethiger, Christoph B

    2015-10-01

    An anesthesia preinduction checklist (APIC) to be performed before anesthesia induction was introduced and evaluated with respect to 5 team-level outcomes, each being a surrogate end point for patient safety: information exchange (the percentage of checklist items exchanged by a team, out of 12 total items); knowledge of critical information (the percentage of critical information items out of 5 total items such as allergies, reported as known by the members of a team); team members' perceptions of safety (the median scores given by the members of a team on a continuous rating scale); their perception of teamwork (the median scores given by the members of a team on a continuous rating scale); and clinical performance (the percentage of completed items out of 14 required tasks, e.g., suction device checked). A prospective interventional study comparing anesthesia teams using the APIC with a control group not using the APIC was performed using a multimethod design. Trained observers rated information exchange and clinical performance during on-site observations of anesthesia inductions. After the observations, each team member indicated the critical information items they knew and their perceptions of safety and teamwork. One hundred five teams using the APIC were compared with 100 teams not doing so. The medians of the team-level outcome scores in the APIC group versus the control group were as follows: information exchange: 100% vs 33% (P < 0.001), knowledge of critical information: 100% vs 90% (P < 0.001), perception of safety: 91% vs 84% (P < 0.001), perception of teamwork: 90% vs 86% (P = 0.028), and clinical performance: 93% vs 93% (P = 0.60). This study provides empirical evidence that the use of a preinduction checklist significantly improves information exchange, knowledge of critical information, and perception of safety in anesthesia teams-all parameters contributing to patient safety. There was a trend indicating improved perception of teamwork.

  11. Motorcycles that See: Multifocal Stereo Vision Sensor for Advanced Safety Systems in Tilting Vehicles

    PubMed Central

    2018-01-01

    Advanced driver assistance systems, ADAS, have shown the possibility to anticipate crash accidents and effectively assist road users in critical traffic situations. This is not the case for motorcyclists, in fact ADAS for motorcycles are still barely developed. Our aim was to study a camera-based sensor for the application of preventive safety in tilting vehicles. We identified two road conflict situations for which automotive remote sensors installed in a tilting vehicle are likely to fail in the identification of critical obstacles. Accordingly, we set two experiments conducted in real traffic conditions to test our stereo vision sensor. Our promising results support the application of this type of sensors for advanced motorcycle safety applications. PMID:29351267

  12. 76 FR 69764 - Petitions for Modification of Application of Existing Mandatory Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-09

    ... DEPARTMENT OF LABOR Mine Safety and Health Administration Petitions for Modification of Application of Existing Mandatory Safety Standards AGENCY: Mine Safety and Health Administration, Labor. ACTION: Notice. SUMMARY: Section 101(c) of the Federal Mine Safety and Health Act of 1977 and 30 CFR part...

  13. Mobile healthcare applications: system design review, critical issues and challenges.

    PubMed

    Baig, Mirza Mansoor; GholamHosseini, Hamid; Connolly, Martin J

    2015-03-01

    Mobile phones are becoming increasingly important in monitoring and delivery of healthcare interventions. They are often considered as pocket computers, due to their advanced computing features, enhanced preferences and diverse capabilities. Their sophisticated sensors and complex software applications make the mobile healthcare (m-health) based applications more feasible and innovative. In a number of scenarios user-friendliness, convenience and effectiveness of these systems have been acknowledged by both patients as well as healthcare providers. M-health technology employs advanced concepts and techniques from multidisciplinary fields of electrical engineering, computer science, biomedical engineering and medicine which benefit the innovations of these fields towards healthcare systems. This paper deals with two important aspects of current mobile phone based sensor applications in healthcare. Firstly, critical review of advanced applications such as; vital sign monitoring, blood glucose monitoring and in-built camera based smartphone sensor applications. Secondly, investigating challenges and critical issues related to the use of smartphones in healthcare including; reliability, efficiency, mobile phone platform variability, cost effectiveness, energy usage, user interface, quality of medical data, and security and privacy. It was found that the mobile based applications have been widely developed in recent years with fast growing deployment by healthcare professionals and patients. However, despite the advantages of smartphones in patient monitoring, education, and management there are some critical issues and challenges related to security and privacy of data, acceptability, reliability and cost that need to be addressed.

  14. Geophysics applications in critical zone science: emerging topics

    USDA-ARS?s Scientific Manuscript database

    Geophysical studies have resulted in remarkable advances in characterization of critical zone. The geophysics applications uncover the relationships between structure and function in subsurface as they seek to define subsurface structural units with individual properties of retention and trans...

  15. [Application of Raman Spectroscopy Technique to Agricultural Products Quality and Safety Determination].

    PubMed

    Liu, Yan-de; Jin, Tan-tan

    2015-09-01

    The quality and safety of agricultural products and people health are inseparable. Using the conventional chemical methods which have so many defects, such as sample pretreatment, complicated operation process and destroying the samples. Raman spectroscopy as a powerful tool of analysing and testing molecular structure, can implement samples quickly without damage, qualitative and quantitative detection analysis. With the continuous improvement and the scope of the application of Raman spectroscopy technology gradually widen, Raman spectroscopy technique plays an important role in agricultural products quality and safety determination, and has wide application prospects. There have been a lot of related research reports based on Raman spectroscopy detection on agricultural product quality safety at present. For the understanding of the principle of detection and the current development situation of Raman spectroscopy, as well as tracking the latest research progress both at home and abroad, the basic principles and the development of Raman spectroscopy as well as the detection device were introduced briefly. The latest research progress of quality and safety determination in fruits and vegetables, livestock and grain by Raman spectroscopy technique were reviewed deeply. Its technical problems for agricultural products quality and safety determination were pointed out. In addition, the text also briefly introduces some information of Raman spectrometer and the application for patent of the portable Raman spectrometer, prospects the future research and application.

  16. Commercial driver rest & parking requirements : making space for safety

    DOT National Transportation Integrated Search

    2014-01-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities suffered on our roads and highways, as well as enabling reductions in traffic congestion and effects on the environment. As a critic...

  17. Safety survey report EBR-II safety survey, ANL-west health protection, industrial safety and fire protection survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunbar, K.A.

    1972-01-10

    A safety survey covering the disciplines of Reactor Safety, Nuclear Criticality Safety, Health Protection and Industrial Safety and Fire Protection was conducted at the ANL-West EBR-II FEF Complex during the period January 10-18, 1972. In addition, the entire ANL-West site was surveyed for Health Protection and Industrial Safety and Fire Protection. The survey was conducted by members of the AEC Chicago Operations Office, a member of RDT-HQ and a member of the RDT-ID site office. Eighteen recommendations resulted from the survey, eleven in the area of Industrial Safety and Fire Protection, five in the area of Reactor Safety and twomore » in the area of Nuclear Criticality Safety.« less

  18. Criticality safety evaluation for the Advanced Test Reactor enhanced low enriched uranium fuel elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montierth, Leland M.

    2016-07-19

    The Global Threat Reduction Initiative (GTRI) convert program is developing a high uranium density fuel based on a low enriched uranium (LEU) uranium-molybdenum alloy. Testing of prototypic GTRI fuel elements is necessary to demonstrate integrated fuel performance behavior and scale-up of fabrication techniques. GTRI Enhanced LEU Fuel (ELF) elements based on the ATR-Standard Size elements (all plates fueled) are to be fabricated for testing in the Advanced Test Reactor (ATR). While a specific ELF element design will eventually be provided for detailed analyses and in-core testing, this criticality safety evaluation (CSE) is intended to evaluate a hypothetical ELF element designmore » for criticality safety purposes. Existing criticality analyses have analyzed Standard (HEU) ATR elements from which controls have been derived. This CSE documents analysis that determines the reactivity of the hypothetical ELF fuel elements relative to HEU ATR elements and whether the existing HEU ATR element controls bound the ELF element. The initial calculations presented in this CSE analyzed the original ELF design, now referred to as Mod 0.1. In addition, as part of a fuel meat thickness optimization effort for reactor performance, other designs have been evaluated. As of early 2014 the most current conceptual designs are Mk1A and Mk1B, that were previously referred to as conceptual designs Mod 0.10 and Mod 0.11, respectively. Revision 1 evaluates the reactivity of the ATR HEU Mark IV elements for a comparison with the Mark VII elements.« less

  19. Point-of-Care Ultrasonography in Emergency and Critical Care Medicine.

    PubMed

    Chen, Leon; Malek, Tony

    To stabilize critically ill patients, emergency and critical care medicine providers often require rapid diagnosis and intervention. The demand for a safe, timely diagnostic device, alongside technological innovation, led to the advent of point-of-care ultrasonography (POCUS). POCUS allows the provider to gain invaluable clinical information with a high level of accuracy, leading to better clinical decision-making and improvements in patient safety. We have outlined the history of POCUS adaptation in emergency and critical care medicine and various clinical applications of POCUS described in literature.

  20. 29 CFR 500.130 - Application and scope of safety and health requirement.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of the aforesaid capacities. (d) The Occupational Safety and Health Administration (OSHA) is the agency of the U.S. Department of Labor which administers the Occupational Safety and Health Act (29 U.S.C... 29 Labor 3 2010-07-01 2010-07-01 false Application and scope of safety and health requirement. 500...

  1. Trends in HFE Methods and Tools and Their Applicability to Safety Reviews

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Hara, J.M.; Plott, C.; Milanski, J.

    2009-09-30

    The U.S. Nuclear Regulatory Commission's (NRC) conducts human factors engineering (HFE) safety reviews of applicant submittals for new plants and for changes to existing plants. The reviews include the evaluation of the methods and tools (M&T) used by applicants as part of their HFE program. The technology used to perform HFE activities has been rapidly evolving, resulting in a whole new generation of HFE M&Ts. The objectives of this research were to identify the current trends in HFE methods and tools, determine their applicability to NRC safety reviews, and identify topics for which the NRC may need additional guidance tomore » support the NRC's safety reviews. We conducted a survey that identified over 100 new HFE M&Ts. The M&Ts were assessed to identify general trends. Seven trends were identified: Computer Applications for Performing Traditional Analyses, Computer-Aided Design, Integration of HFE Methods and Tools, Rapid Development Engineering, Analysis of Cognitive Tasks, Use of Virtual Environments and Visualizations, and Application of Human Performance Models. We assessed each trend to determine its applicability to the NRC's review by considering (1) whether the nuclear industry is making use of M&Ts for each trend, and (2) whether M&Ts reflecting the trend can be reviewed using the current design review guidance. We concluded that M&T trends that are applicable to the commercial nuclear industry and are expected to impact safety reviews may be considered for review guidance development. Three trends fell into this category: Analysis of Cognitive Tasks, Use of Virtual Environments and Visualizations, and Application of Human Performance Models. The other trends do not need to be addressed at this time.« less

  2. 77 FR 60479 - Burnup Credit in the Criticality Safety Analyses of Pressurized Water Reactor Spent Fuel in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-03

    ... Pressurized Water Reactor Spent Fuel in Transportation and Storage Casks AGENCY: Nuclear Regulatory Commission... 3, entitled, ``Burnup Credit in the Criticality Safety Analyses of PWR [Pressurized Water Reactor... water reactor spent nuclear fuel (SNF) in transportation packages and storage casks. SFST-ISG-8...

  3. Software Reliability Issues Concerning Large and Safety Critical Software Systems

    NASA Technical Reports Server (NTRS)

    Kamel, Khaled; Brown, Barbara

    1996-01-01

    This research was undertaken to provide NASA with a survey of state-of-the-art techniques using in industrial and academia to provide safe, reliable, and maintainable software to drive large systems. Such systems must match the complexity and strict safety requirements of NASA's shuttle system. In particular, the Launch Processing System (LPS) is being considered for replacement. The LPS is responsible for monitoring and commanding the shuttle during test, repair, and launch phases. NASA built this system in the 1970's using mostly hardware techniques to provide for increased reliability, but it did so often using custom-built equipment, which has not been able to keep up with current technologies. This report surveys the major techniques used in industry and academia to ensure reliability in large and critical computer systems.

  4. 76 FR 15046 - Office of Hazardous Materials Safety; Notice of Applications for Modification of Special Permit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-18

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Applications for Modification of Special Permit AGENCY: Pipeline and Hazardous Materials Safety Administration (PHMSA), DOT. ACTION: List of applications for modification of...

  5. Safe laser application requires more than laser safety

    NASA Astrophysics Data System (ADS)

    Frevel, A.; Steffensen, B.; Vassie, L.

    1995-02-01

    An overview is presented concerning aspects of laser safety in European industrial laser use. Surveys indicate that there is a large variation in the safety strategies amongst industrial laser users. Some key problem areas are highlighted. Emission of hazardous substances is a major problem for users of laser material processing systems where the majority of the particulate is of a sub-micrometre size, presenting a respiratory hazard. Studies show that in many cases emissions are not frequently monitored in factories and uncertainty exists over the hazards. Operators of laser machines do not receive adequate job training or safety training. The problem is compounded by a plethora of regulations and standards which are difficult to interpret and implement, and inspectors who are not conversant with the technology or the issues. A case is demonstrated for a more integrated approach to laser safety, taking into account the development of laser applications, organizational and personnel development, in addition to environmental and occupational health and safety aspects. It is necessary to achieve a harmonization between these elements in any organization involved in laser technology. This might be achieved through establishing technology transfer centres in laser technology.

  6. An Evaluation Tool for Agricultural Health and Safety Mobile Applications.

    PubMed

    Reyes, Iris; Ellis, Tammy; Yoder, Aaron; Keifer, Matthew C

    2016-01-01

    As the use of mobile devices and their software applications, or apps, becomes ubiquitous, use amongst agricultural working populations is expanding as well. The smart device paired with a well-designed app has potential for improving workplace health and safety in the hands of those who can act upon the information provided. Many apps designed to assess workplace hazards and implementation of worker protections already exist. However, the abundance and diversity of such applications also presents challenges regarding evaluation practices and assignation of value. This is particularly true in the agricultural workspace, as there is currently little information on the value of these apps for agricultural safety and health. This project proposes a framework for developing and evaluating apps that have potential usefulness in agricultural health and safety. The evaluation framework is easily transferable, with little modification for evaluation of apps in several agriculture-specific areas.

  7. 77 FR 46797 - Notice of Fiscal Year 2013 Safety Grants and Solicitation for Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-06

    ... emphasis on texting and hand-held cell phone prohibitions, work zone enforcement, rural road safety, and... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration Notice of Fiscal Year 2013 Safety Grants and Solicitation for Applications AGENCY: Federal Motor Carrier Safety...

  8. Radio-Frequency Applications for Food Processing and Safety.

    PubMed

    Jiao, Yang; Tang, Juming; Wang, Yifen; Koral, Tony L

    2018-03-25

    Radio-frequency (RF) heating, as a thermal-processing technology, has been extending its applications in the food industry. Although RF has shown some unique advantages over conventional methods in industrial drying and frozen food thawing, more research is needed to make it applicable for food safety applications because of its complex heating mechanism. This review provides comprehensive information regarding RF-heating history, mechanism, fundamentals, and applications that have already been fully developed or are still under research. The application of mathematical modeling as a useful tool in RF food processing is also reviewed in detail. At the end of the review, we summarize the active research groups in the RF food thermal-processing field, and address the current problems that still need to be overcome.

  9. Deriving Safety Cases from Machine-Generated Proofs

    NASA Technical Reports Server (NTRS)

    Basir, Nurlida; Fischer, Bernd; Denney, Ewen

    2009-01-01

    Proofs provide detailed justification for the validity of claims and are widely used in formal software development methods. However, they are often complex and difficult to understand, because they use machine-oriented formalisms; they may also be based on assumptions that are not justified. This causes concerns about the trustworthiness of using formal proofs as arguments in safety-critical applications. Here, we present an approach to develop safety cases that correspond to formal proofs found by automated theorem provers and reveal the underlying argumentation structure and top-level assumptions. We concentrate on natural deduction proofs and show how to construct the safety cases by covering the proof tree with corresponding safety case fragments.

  10. Evaluation of Fission Product Critical Experiments and Associated Biases for Burnup Credit Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mueller, Don; Rearden, Bradley T; Reed, Davis Allan

    2010-01-01

    One of the challenges associated with implementation of burnup credit is the validation of criticality calculations used in the safety evaluation; in particular the availability and use of applicable critical experiment data. The purpose of the validation is to quantify the relationship between reality and calculated results. Validation and determination of bias and bias uncertainty require the identification of sets of critical experiments that are similar to the criticality safety models. A principal challenge for crediting fission products (FP) in a burnup credit safety evaluation is the limited availability of relevant FP critical experiments for bias and bias uncertainty determination.more » This paper provides an evaluation of the available critical experiments that include FPs, along with bounding, burnup-dependent estimates of FP biases generated by combining energy dependent sensitivity data for a typical burnup credit application with the nuclear data uncertainty information distributed with SCALE 6. A method for determining separate bias and bias uncertainty values for individual FPs and illustrative results is presented. Finally, a FP bias calculation method based on data adjustment techniques and reactivity sensitivity coefficients calculated with the SCALE sensitivity/uncertainty tools and some typical results is presented. Using the methods described in this paper, the cross-section bias for a representative high-capacity spent fuel cask associated with the ENDF/B-VII nuclear data for 16 most important stable or near stable FPs is predicted to be no greater than 2% of the total worth of the 16 FPs, or less than 0.13 % k/k.« less

  11. 12 CFR 1229.10 - Actions applicable to critically undercapitalized Banks.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Actions applicable to critically undercapitalized Banks. 1229.10 Section 1229.10 Banks and Banking FEDERAL HOUSING FINANCE AGENCY ENTITY REGULATIONS CAPITAL CLASSIFICATIONS AND PROMPT CORRECTIVE ACTION Federal Home Loan Banks § 1229.10 Actions applicable...

  12. 14 CFR 1214.501 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Applicability. 1214.501 Section 1214.501 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION SPACE FLIGHT Mission Critical Space System... the safety and success of mission critical space systems. (b) The provisions of this regulation apply...

  13. 14 CFR 1214.501 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Applicability. 1214.501 Section 1214.501 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION SPACE FLIGHT Mission Critical Space System... the safety and success of mission critical space systems. (b) The provisions of this regulation apply...

  14. 14 CFR 1214.501 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Applicability. 1214.501 Section 1214.501 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION SPACE FLIGHT Mission Critical Space System... the safety and success of mission critical space systems. (b) The provisions of this regulation apply...

  15. 14 CFR 1214.501 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Applicability. 1214.501 Section 1214.501 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION SPACE FLIGHT Mission Critical Space System... the safety and success of mission critical space systems. (b) The provisions of this regulation apply...

  16. Materials for lithium-ion battery safety.

    PubMed

    Liu, Kai; Liu, Yayuan; Lin, Dingchang; Pei, Allen; Cui, Yi

    2018-06-01

    Lithium-ion batteries (LIBs) are considered to be one of the most important energy storage technologies. As the energy density of batteries increases, battery safety becomes even more critical if the energy is released unintentionally. Accidents related to fires and explosions of LIBs occur frequently worldwide. Some have caused serious threats to human life and health and have led to numerous product recalls by manufacturers. These incidents are reminders that safety is a prerequisite for batteries, and serious issues need to be resolved before the future application of high-energy battery systems. This Review aims to summarize the fundamentals of the origins of LIB safety issues and highlight recent key progress in materials design to improve LIB safety. We anticipate that this Review will inspire further improvement in battery safety, especially for emerging LIBs with high-energy density.

  17. Materials for lithium-ion battery safety

    PubMed Central

    Liu, Kai

    2018-01-01

    Lithium-ion batteries (LIBs) are considered to be one of the most important energy storage technologies. As the energy density of batteries increases, battery safety becomes even more critical if the energy is released unintentionally. Accidents related to fires and explosions of LIBs occur frequently worldwide. Some have caused serious threats to human life and health and have led to numerous product recalls by manufacturers. These incidents are reminders that safety is a prerequisite for batteries, and serious issues need to be resolved before the future application of high-energy battery systems. This Review aims to summarize the fundamentals of the origins of LIB safety issues and highlight recent key progress in materials design to improve LIB safety. We anticipate that this Review will inspire further improvement in battery safety, especially for emerging LIBs with high-energy density. PMID:29942858

  18. Software Safety Progress in NASA

    NASA Technical Reports Server (NTRS)

    Radley, Charles F.

    1995-01-01

    NASA has developed guidelines for development and analysis of safety-critical software. These guidelines have been documented in a Guidebook for Safety Critical Software Development and Analysis. The guidelines represent a practical 'how to' approach, to assist software developers and safety analysts in cost effective methods for software safety. They provide guidance in the implementation of the recent NASA Software Safety Standard NSS-1740.13 which was released as 'Interim' version in June 1994, scheduled for formal adoption late 1995. This paper is a survey of the methods in general use, resulting in the NASA guidelines for safety critical software development and analysis.

  19. Discrete Abstractions of Hybrid Systems: Verification of Safety and Application to User-Interface Design

    NASA Technical Reports Server (NTRS)

    Oishi, Meeko; Tomlin, Claire; Degani, Asaf

    2003-01-01

    Human interaction with complex hybrid systems involves the user, the automation's discrete mode logic, and the underlying continuous dynamics of the physical system. Often the user-interface of such systems displays a reduced set of information about the entire system. In safety-critical systems, how can we identify user-interface designs which do not have adequate information, or which may confuse the user? Here we describe a methodology, based on hybrid system analysis, to verify that a user-interface contains information necessary to safely complete a desired procedure or task. Verification within a hybrid framework allows us to account for the continuous dynamics underlying the simple, discrete representations displayed to the user. We provide two examples: a car traveling through a yellow light at an intersection and an aircraft autopilot in a landing/go-around maneuver. The examples demonstrate the general nature of this methodology, which is applicable to hybrid systems (not fully automated) which have operational constraints we can pose in terms of safety. This methodology differs from existing work in hybrid system verification in that we directly account for the user's interactions with the system.

  20. Rubber dam application in endodontic practice: an update on critical educational and ethical dilemmas.

    PubMed

    Ahmed, H M A; Cohen, S; Lévy, G; Steier, L; Bukiet, F

    2014-12-01

    Proper isolation is an essential prerequisite for successful endodontic treatment. This article aims to provide an update on the prevalence of rubber dam (RD) use, and the role of education along with attitudes of general dental practitioners (GDPs) and patients towards the application of RD in endodontics. Critical ethical issues are also highlighted. Using certain keywords, an electronic search was conducted spanning the period from January 1983 to April 2013 to identify the available related investigations, and the pooled data were then analysed. The results show that although RD is the Standard of Care in endodontic practice, there is a clear discrepancy in what GDPs are taught in dental school and what they practice after graduation. There is little scientific evidence to support the application of RD; however, patient safety and clinical practice guidelines indicate that it is unnecessary and unethical to consider a cohort study to prove what is already universally agreed upon. A few clinical situations may require special management which should be highlighted in the current guidelines. This would pave the way for clear and straightforward universal guidelines. © 2014 Australian Dental Association.

  1. Water Resistant Container Technical Basis Document for the TA-55 Criticality Safety Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Paul Herrick; Teague, Jonathan Gayle

    Criticality safety at TA-55 relies on nuclear material containers that are water resistant to prevent significant amounts of water from coming into contact with fissile material in the event of a fire that causes a breach of glovevbox confinement and subsequent fire water ingress. A “water tight container” is a container that will not allow more than 50ml of water ingress when fully submerged, except when under sufficient pressure to produce structural discontinuity. There are many types of containers, welded containers, hermetically sealed containers, filtered containers, etc.

  2. Application of queueing models to multiprogrammed computer systems operating in a time-critical environment

    NASA Technical Reports Server (NTRS)

    Eckhardt, D. E., Jr.

    1979-01-01

    A model of a central processor (CPU) which services background applications in the presence of time critical activity is presented. The CPU is viewed as an M/M/1 queueing system subject to periodic interrupts by deterministic, time critical process. The Laplace transform of the distribution of service times for the background applications is developed. The use of state of the art queueing models for studying the background processing capability of time critical computer systems is discussed and the results of a model validation study which support this application of queueing models are presented.

  3. Enhancing the Safety of Children in Foster Care and Family Support Programs: Automated Critical Incident Reporting

    ERIC Educational Resources Information Center

    Brenner, Eliot; Freundlich, Madelyn

    2006-01-01

    The Adoption and Safe Families Act of 1997 has made child safety an explicit focus in child welfare. The authors describe an automated critical incident reporting program designed for use in foster care and family-support programs. The program, which is based in Lotus Notes and uses e-mail to route incident reports from direct service staff to…

  4. Connected commercial vehicles — retrofit safety device kit project : applications performance and functional test report.

    DOT National Transportation Integrated Search

    2014-03-01

    Connected vehicle wireless data communications can enable safety applications that may reduce injuries and fatalities. Cooperative vehicle-to-vehicle (V2V) safety applications will be effective only if a high fraction of vehicles are equipped. Deploy...

  5. Safety Characteristics in System Application Software for Human Rated Exploration

    NASA Technical Reports Server (NTRS)

    Mango, E. J.

    2016-01-01

    NASA and its industry and international partners are embarking on a bold and inspiring development effort to design and build an exploration class space system. The space system is made up of the Orion system, the Space Launch System (SLS) and the Ground Systems Development and Operations (GSDO) system. All are highly coupled together and dependent on each other for the combined safety of the space system. A key area of system safety focus needs to be in the ground and flight application software system (GFAS). In the development, certification and operations of GFAS, there are a series of safety characteristics that define the approach to ensure mission success. This paper will explore and examine the safety characteristics of the GFAS development.

  6. Critical review of the current literature on the safety of sucralose.

    PubMed

    Magnuson, Bernadene A; Roberts, Ashley; Nestmann, Earle R

    2017-08-01

    Sucralose is a non-caloric high intensity sweetener that is approved globally for use in foods and beverages. This review provides an updated summary of the literature addressing the safety of use of sucralose. Studies reviewed include chemical characterization and stability, toxicokinetics in animals and humans, assessment of genotoxicity, and animal and human feeding studies. Endpoints evaluated include effects on growth, development, reproduction, neurotoxicity, immunotoxicity, carcinogenicity and overall health status. Human clinical studies investigated potential effects of repeated consumption in individuals with diabetes. Recent studies on the safety of sucralose focused on carcinogenic potential and the effect of sucralose on the gut microflora are reviewed. Following the discovery of sweet taste receptors in the gut and studies investigating the activation of these receptors by sucralose lead to numerous human clinical studies assessing the effect of sucralose on overall glycemic control. Estimated daily intakes of sucralose in different population subgroups, including recent studies on children with special dietary needs, consistently find that the intakes of sucralose in all members of the population remain well below the acceptable daily intake. Collectively, critical review of the extensive database of research demonstrates that sucralose is safe for its intended use as a non-caloric sugar alternative. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. [Design of a Hazard Analysis and Critical Control Points (HACCP) plan to assure the safety of a bologna product produced by a meat processing plant].

    PubMed

    Bou Rached, Lizet; Ascanio, Norelis; Hernández, Pilar

    2004-03-01

    The Hazard Analysis and Critical Control Point (HACCP) is a systematic integral program used to identify and estimate the hazards (microbiological, chemical and physical) and the risks generated during the primary production, processing, storage, distribution, expense and consumption of foods. To establish a program of HACCP has advantages, being some of them: to emphasize more in the prevention than in the detection, to diminish the costs, to minimize the risk of manufacturing faulty products, to allow bigger trust to the management, to strengthen the national and international competitiveness, among others. The present work is a proposal based on the design of an HACCP program to guarantee the safety of the Bologna Special Type elaborated by a meat products industry, through the determination of hazards (microbiological, chemical or physical), the identification of critical control points (CCP), the establishment of critical limits, plan corrective actions and the establishment of documentation and verification procedures. The used methodology was based in the application of the seven basic principles settled down by the Codex Alimentarius, obtaining the design of this program. In view of the fact that recently the meat products are linked with pathogens like E. coli O157:H7 and Listeria monocytogenes, these were contemplated as microbiological hazard for the establishment of the HACCP plan whose application will guarantee the obtaining of a safe product.

  8. Generating Safety-Critical PLC Code From a High-Level Application Software Specification

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The benefits of automatic-application code generation are widely accepted within the software engineering community. These benefits include raised abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at Kennedy Space Center recognized the need for PLC code generation while developing the new ground checkout and launch processing system, called the Launch Control System (LCS). Engineers developed a process and a prototype software tool that automatically translates a high-level representation or specification of application software into ladder logic that executes on a PLC. All the computer hardware in the LCS is planned to be commercial off the shelf (COTS), including industrial controllers or PLCs that are connected to the sensors and end items out in the field. Most of the software in LCS is also planned to be COTS, with only small adapter software modules that must be developed in order to interface between the various COTS software products. A domain-specific language (DSL) is a programming language designed to perform tasks and to solve problems in a particular domain, such as ground processing of launch vehicles. The LCS engineers created a DSL for developing test sequences of ground checkout and launch operations of future launch vehicle and spacecraft elements, and they are developing a tabular specification format that uses the DSL keywords and functions familiar to the ground and flight system users. The tabular specification format, or tabular spec, allows most ground and flight system users to document how the application software is intended to function and requires little or no software programming knowledge or experience. A small sample from a prototype tabular spec application is

  9. Building effective critical care teams

    PubMed Central

    2011-01-01

    Critical care is formulated and delivered by a team. Accordingly, behavioral scientific principles relevant to teams, namely psychological safety, transactive memory and leadership, apply to critical care teams. Two experts in behavioral sciences review the impact of psychological safety, transactive memory and leadership on medical team outcomes. A clinician then applies those principles to two routine critical care paradigms: daily rounds and resuscitations. Since critical care is a team endeavor, methods to maximize teamwork should be learned and mastered by critical care team members, and especially leaders. PMID:21884639

  10. Fault Tree Analysis Application for Safety and Reliability

    NASA Technical Reports Server (NTRS)

    Wallace, Dolores R.

    2003-01-01

    Many commercial software tools exist for fault tree analysis (FTA), an accepted method for mitigating risk in systems. The method embedded in the tools identifies a root as use in system components, but when software is identified as a root cause, it does not build trees into the software component. No commercial software tools have been built specifically for development and analysis of software fault trees. Research indicates that the methods of FTA could be applied to software, but the method is not practical without automated tool support. With appropriate automated tool support, software fault tree analysis (SFTA) may be a practical technique for identifying the underlying cause of software faults that may lead to critical system failures. We strive to demonstrate that existing commercial tools for FTA can be adapted for use with SFTA, and that applied to a safety-critical system, SFTA can be used to identify serious potential problems long before integrator and system testing.

  11. Toward an Application Guide for Safety Integrity Level Allocation in Railway Systems.

    PubMed

    Ouedraogo, Kiswendsida Abel; Beugin, Julie; El-Koursi, El-Miloudi; Clarhaut, Joffrey; Renaux, Dominique; Lisiecki, Frederic

    2018-02-02

    The work in the article presents the development of an application guide based on feedback and comments stemming from various railway actors on their practices of SIL allocation to railway safety-related functions. The initial generic methodology for SIL allocation has been updated to be applied to railway rolling stock safety-related functions in order to solve the SIL concept application issues. Various actors dealing with railway SIL allocation problems are the intended target of the methodology; its principles will be summarized in this article with a focus on modifications and precisions made in order to establish a practical guide for railway safety authorities. The methodology is based on the flowchart formalism used in CSM (common safety method) European regulation. It starts with the use of quantitative safety requirements, particularly tolerable hazard rates (THR). THR apportioning rules are applied. On the one hand, the rules are related to classical logical combinations of safety-related functions preventing hazard occurrence. On the other hand, to take into account technical conditions (last safety weak link, functional dependencies, technological complexity, etc.), specific rules implicitly used in existing practices are defined for readjusting some THR values. SIL allocation process based on apportioned and validated THR values is finally illustrated through the example of "emergency brake" subsystems. Some specific SIL allocation rules are also defined and illustrated. © 2018 Society for Risk Analysis.

  12. 75 FR 40023 - Notice of Fiscal Year 2011 Safety Grants and Solicitation for Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-13

    ... safety agencies. For grants awarded for public education activities, the Federal share will be 100... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [FMCSA Docket No. FMCSA-2010-0212] Notice of Fiscal Year 2011 Safety Grants and Solicitation for Applications AGENCY: Federal...

  13. Critical spaces for quasilinear parabolic evolution equations and applications

    NASA Astrophysics Data System (ADS)

    Prüss, Jan; Simonett, Gieri; Wilke, Mathias

    2018-02-01

    We present a comprehensive theory of critical spaces for the broad class of quasilinear parabolic evolution equations. The approach is based on maximal Lp-regularity in time-weighted function spaces. It is shown that our notion of critical spaces coincides with the concept of scaling invariant spaces in case that the underlying partial differential equation enjoys a scaling invariance. Applications to the vorticity equations for the Navier-Stokes problem, convection-diffusion equations, the Nernst-Planck-Poisson equations in electro-chemistry, chemotaxis equations, the MHD equations, and some other well-known parabolic equations are given.

  14. Applications of aerospace technology in industry, a technology transfer profile: Fire safety

    NASA Technical Reports Server (NTRS)

    Kottenstette, J. P.; Freeman, J. E.; Heins, C. R.; Hildred, W. M.; Johnson, F. D.; Staskin, E. R.

    1971-01-01

    The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined.

  15. The International Safety Framework for nuclear power source applications in outer space-Useful and substantial guidance

    NASA Astrophysics Data System (ADS)

    Summerer, L.; Wilcox, R. E.; Bechtel, R.; Harbison, S.

    2015-06-01

    In 2009, the International Safety Framework for Nuclear Power Source Applications in Outer Space was adopted, following a multi-year process that involved all major space faring nations under the auspices of a partnership between the UN Committee on the Peaceful Uses of Outer Space and the International Atomic Energy Agency. The Safety Framework reflects an international consensus on best practices to achieve safety. Following the 1992 UN Principles Relevant to the Use of Nuclear Power Sources in Outer Space, it is the second attempt by the international community to draft guidance promoting the safety of applications of nuclear power sources in space missions. NPS applications in space have unique safety considerations compared with terrestrial applications. Mission launch and outer space operational requirements impose size, mass and other space environment limitations not present for many terrestrial nuclear facilities. Potential accident conditions could expose nuclear power sources to extreme physical conditions. The Safety Framework is structured to provide guidance for both the programmatic and technical aspects of safety. In addition to sections containing specific guidance for governments and for management, it contains technical guidance pertinent to the design, development and all mission phases of space NPS applications. All sections of the Safety Framework contain elements directly relevant to engineers and space mission designers for missions involving space nuclear power sources. The challenge for organisations and engineers involved in the design and development processes of space nuclear power sources and applications is to implement the guidance provided in the Safety Framework by integrating it into the existing standard space mission infrastructure of design, development and operational requirements, practices and processes. This adds complexity to the standard space mission and launch approval processes. The Safety Framework is deliberately

  16. Software Dependability and Safety Evaluations ESA's Initiative

    NASA Astrophysics Data System (ADS)

    Hernek, M.

    ESA has allocated funds for an initiative to evaluate Dependability and Safety methods of Software. The objectives of this initiative are; · More extensive validation of Safety and Dependability techniques for Software · Provide valuable results to improve the quality of the Software thus promoting the application of Dependability and Safety methods and techniques. ESA space systems are being developed according to defined PA requirement specifications. These requirements may be implemented through various design concepts, e.g. redundancy, diversity etc. varying from project to project. Analysis methods (FMECA. FTA, HA, etc) are frequently used during requirements analysis and design activities to assure the correct implementation of system PA requirements. The criticality level of failures, functions and systems is determined and by doing that the critical sub-systems are identified, on which dependability and safety techniques are to be applied during development. Proper performance of the software development requires the development of a technical specification for the products at the beginning of the life cycle. Such technical specification comprises both functional and non-functional requirements. These non-functional requirements address characteristics of the product such as quality, dependability, safety and maintainability. Software in space systems is more and more used in critical functions. Also the trend towards more frequent use of COTS and reusable components pose new difficulties in terms of assuring reliable and safe systems. Because of this, its dependability and safety must be carefully analysed. ESA identified and documented techniques, methods and procedures to ensure that software dependability and safety requirements are specified and taken into account during the design and development of a software system and to verify/validate that the implemented software systems comply with these requirements [R1].

  17. The Application of Software Safety to the Constellation Program Launch Control System

    NASA Technical Reports Server (NTRS)

    Kania, James; Hill, Janice

    2011-01-01

    The application of software safety practices on the LCS project resulted in the successful implementation of the NASA Software Safety Standard NASA-STD-8719.138 and CxP software safety requirements. The GOP-GEN-GSW-011 Hazard Report was the first report developed at KSC to identify software hazard causes and their controls. This approach can be applied to similar large software - intensive systems where loss of control can lead to a hazard.

  18. Automatic programming for critical applications

    NASA Technical Reports Server (NTRS)

    Loganantharaj, Raj L.

    1988-01-01

    The important phases of a software life cycle include verification and maintenance. Usually, the execution performance is an expected requirement in a software development process. Unfortunately, the verification and the maintenance of programs are the time consuming and the frustrating aspects of software engineering. The verification cannot be waived for the programs used for critical applications such as, military, space, and nuclear plants. As a consequence, synthesis of programs from specifications, an alternative way of developing correct programs, is becoming popular. The definition, or what is understood by automatic programming, has been changed with our expectations. At present, the goal of automatic programming is the automation of programming process. Specifically, it means the application of artificial intelligence to software engineering in order to define techniques and create environments that help in the creation of high level programs. The automatic programming process may be divided into two phases: the problem acquisition phase and the program synthesis phase. In the problem acquisition phase, an informal specification of the problem is transformed into an unambiguous specification while in the program synthesis phase such a specification is further transformed into a concrete, executable program.

  19. Independent evaluation of light-vehicle safety applications based on vehicle-to-vehicle communications used in the 2012-2013 safety pilot model deployment

    DOT National Transportation Integrated Search

    2015-12-01

    This report presents the methodology and results of the independent evaluation of safety applications for passenger vehicles in the 2012-2013 Safety Pilot Model Deployment, part of the United States Department of Transportations Intelligent Transp...

  20. Human factors systems approach to healthcare quality and patient safety

    PubMed Central

    Carayon, Pascale; Wetterneck, Tosha B.; Rivera-Rodriguez, A. Joy; Hundt, Ann Schoofs; Hoonakker, Peter; Holden, Richard; Gurses, Ayse P.

    2013-01-01

    Human factors systems approaches are critical for improving healthcare quality and patient safety. The SEIPS (Systems Engineering Initiative for Patient Safety) model of work system and patient safety is a human factors systems approach that has been successfully applied in healthcare research and practice. Several research and practical applications of the SEIPS model are described. Important implications of the SEIPS model for healthcare system and process redesign are highlighted. Principles for redesigning healthcare systems using the SEIPS model are described. Balancing the work system and encouraging the active and adaptive role of workers are key principles for improving healthcare quality and patient safety. PMID:23845724

  1. Radiation safety standards and their application: international policies and current issues.

    PubMed

    González, Abel J

    2004-09-01

    This paper briefly describes the current policies of the United Nations Scientific Committee on the Effects of Atomic Radiation and the International Commission on Radiological Protection and how these policies are converted into international radiation safety standards by the International Atomic Energy Agency, which is the only global organization-within the United Nations family of international agencies-with a statutory mandate not only to establish such standards but also to provide for their application. It also summarizes the current status of the established corpus of such international standards, and of it foreseeable evolution, as well as of legally binding undertakings by countries around the world that are linked to these standards. Moreover, this paper also reviews some major current global issues related to the application of international standards, including the following: strengthening of national infrastructures for radiation safety, including technical cooperation programs for assisting developing countries; occupational radiation safety challenges, including the protection of pregnant workers and their unborn children, dealing with working environments with high natural radiation levels, and occupational attributability of health effects (probability of occupational causation); restricting discharges of radioactive substances into the environment: reviewing current international policies vis-a-vis the growing concern on the radiation protection of the "environment;" radiological protection of patients undergoing radiodiagnostic and radiotherapeutic procedures: the current International Action Plan; safety and security of radiation sources: post-11 September developments; preparedness and response to radiation emergencies: enhancing the international network; safe transport of radioactive materials: new apprehensions; safety of radioactive waste management: concerns and connections with radiation protection; and radioactive residues remaining

  2. 77 FR 71031 - Office of Hazardous Materials Safety; Actions on Special Permit Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-28

    ...), transportation in commerce 173.465(d). of certain Radioactive material in alternative packaging by highway. A... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Actions on Special Permit Applications AGENCY: Pipeline And Hazardous Materials...

  3. NASA Software Safety Standard

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda

    1997-01-01

    If software is a critical element in a safety critical system, it is imperative to implement a systematic approach to software safety as an integral part of the overall system safety programs. The NASA-STD-8719.13A, "NASA Software Safety Standard", describes the activities necessary to ensure that safety is designed into software that is acquired or developed by NASA, and that safety is maintained throughout the software life cycle. A PDF version, is available on the WWW from Lewis. A Guidebook that will assist in the implementation of the requirements in the Safety Standard is under development at the Lewis Research Center (LeRC). After completion, it will also be available on the WWW from Lewis.

  4. Investigational new drug safety reporting requirements for human drug and biological products and safety reporting requirements for bioavailability and bioequivalence studies in humans. Final rule.

    PubMed

    2010-09-29

    The Food and Drug Administration (FDA) is amending its regulations governing safety reporting requirements for human drug and biological products subject to an investigational new drug application (IND). The final rule codifies the agency's expectations for timely review, evaluation, and submission of relevant and useful safety information and implements internationally harmonized definitions and reporting standards. The revisions will improve the utility of IND safety reports, reduce the number of reports that do not contribute in a meaningful way to the developing safety profile of the drug, expedite FDA's review of critical safety information, better protect human subjects enrolled in clinical trials, subject bioavailability and bioequivalence studies to safety reporting requirements, promote a consistent approach to safety reporting internationally, and enable the agency to better protect and promote public health.

  5. OECD/NEA expert group on uncertainty analysis for criticality safety assessment: Results of benchmark on sensitivity calculation (phase III)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanova, T.; Laville, C.; Dyrda, J.

    2012-07-01

    The sensitivities of the k{sub eff} eigenvalue to neutron cross sections have become commonly used in similarity studies and as part of the validation algorithm for criticality safety assessments. To test calculations of the sensitivity coefficients, a benchmark study (Phase III) has been established by the OECD-NEA/WPNCS/EG UACSA (Expert Group on Uncertainty Analysis for Criticality Safety Assessment). This paper presents some sensitivity results generated by the benchmark participants using various computational tools based upon different computational methods: SCALE/TSUNAMI-3D and -1D, MONK, APOLLO2-MORET 5, DRAGON-SUSD3D and MMKKENO. The study demonstrates the performance of the tools. It also illustrates how model simplificationsmore » impact the sensitivity results and demonstrates the importance of 'implicit' (self-shielding) sensitivities. This work has been a useful step towards verification of the existing and developed sensitivity analysis methods. (authors)« less

  6. An Operational Safety and Certification Assessment of a TASAR EFB Application

    NASA Technical Reports Server (NTRS)

    Koczo, Stefan; Wing, David

    2013-01-01

    This paper presents an overview of a Traffic Aware Strategic Aircrew Requests (TASAR) Electronic Flight Bag application intended to inform the pilot of trajectory improvement opportunities while en route that result in operational benefits. The results of safety analyses and a detailed review of Federal Aviation Administration (FAA) regulatory documents that establish certification and operational approval requirements are presented for TASAR. The safety analyses indicate that TASAR has a likely Failure Effects Classification of “No Effect,” and at most, is no worse than “Minor Effect.” Based on this safety assessment and the detailed review of FAA regulatory documents that determine certification and operational approval requirements, this study concludes that TASAR can be implemented in the flight deck as a Type B software application hosted on a Class 2 Portable Electronic Device (PED) Electronic Flight Bag (EFB). This implementation approach would provide a relatively low-cost path to certification and operational approval for both retrofit and forward fit implementation, while at the same time facilitating the business case for early ADS-B IN equipage. A preliminary review by FAA certification and operational approvers of the analyses presented here confirmed that the conclusions are appropriate and that TASAR will be considered a Type B application.

  7. Applications of Advanced Nondestructive Measurement Techniques to Address Safety of Flight Issues on NASA Spacecraft

    NASA Technical Reports Server (NTRS)

    Prosser, Bill

    2016-01-01

    Advanced nondestructive measurement techniques are critical for ensuring the reliability and safety of NASA spacecraft. Techniques such as infrared thermography, THz imaging, X-ray computed tomography and backscatter X-ray are used to detect indications of damage in spacecraft components and structures. Additionally, sensor and measurement systems are integrated into spacecraft to provide structural health monitoring to detect damaging events that occur during flight such as debris impacts during launch and assent or from micrometeoroid and orbital debris, or excessive loading due to anomalous flight conditions. A number of examples will be provided of how these nondestructive measurement techniques have been applied to resolve safety critical inspection concerns for the Space Shuttle, International Space Station (ISS), and a variety of launch vehicles and unmanned spacecraft.

  8. Nuclear criticality safety calculational analysis for small-diameter containers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeTellier, M.S.; Smallwood, D.J.; Henkel, J.A.

    This report documents calculations performed to establish a technical basis for the nuclear criticality safety of favorable geometry containers, sometimes referred to as 5-inch containers, in use at the Portsmouth Gaseous Diffusion Plant. A list of containers currently used in the plant is shown in Table 1.0-1. These containers are currently used throughout the plant with no mass limits. The use of containers with geometries or material types other than those addressed in this evaluation must be bounded by this analysis or have an additional analysis performed. The following five basic container geometries were modeled and bound all container geometriesmore » in Table 1.0-1: (1) 4.32-inch-diameter by 50-inch-high polyethylene bottle; (2) 5.0-inch-diameter by 24-inch-high polyethylene bottle; (3) 5.25-inch-diameter by 24-inch-high steel can ({open_quotes}F-can{close_quotes}); (4) 5.25-inch-diameter by 15-inch-high steel can ({open_quotes}Z-can{close_quotes}); and (5) 5.0-inch-diameter by 9-inch-high polybottle ({open_quotes}CO-4{close_quotes}). Each container type is evaluated using five basic reflection and interaction models that include single containers and multiple containers in normal and in credible abnormal conditions. The uranium materials evaluated are UO{sub 2}F{sub 2}+H{sub 2}O and UF{sub 4}+oil materials at 100% and 10% enrichments and U{sub 3}O{sub 8}, and H{sub 2}O at 100% enrichment. The design basis safe criticality limit for the Portsmouth facility is k{sub eff} + 2{sigma} < 0.95. The KENO study results may be used as the basis for evaluating general use of these containers in the plant.« less

  9. The Halpern Critical Thinking Assessment and Real-World Outcomes: Cross-National Applications

    ERIC Educational Resources Information Center

    Butler, Heather A.; Dwyer, Christopher P.; Hogan, Michael J.; Franco, Amanda; Rivas, Silvia F.; Saiz, Carlos; Almeida, Leandro S.

    2012-01-01

    The Halpern Critical Thinking Assessment (HCTA) is a reliable measure of critical thinking that has been validated with numerous qualitatively different samples and measures of academic success (Halpern, 2010a). This paper presents several cross-national applications of the assessment, and recent work to expand the validation of the HCTA with…

  10. 10 CFR 70.62 - Safety program and integrated safety analysis.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; (iv) Potential accident sequences caused by process deviations or other events internal to the... of occurrence of each potential accident sequence identified pursuant to paragraph (c)(1)(iv) of this... have experience in nuclear criticality safety, radiation safety, fire safety, and chemical process...

  11. 10 CFR 70.62 - Safety program and integrated safety analysis.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; (iv) Potential accident sequences caused by process deviations or other events internal to the... of occurrence of each potential accident sequence identified pursuant to paragraph (c)(1)(iv) of this... have experience in nuclear criticality safety, radiation safety, fire safety, and chemical process...

  12. 10 CFR 70.62 - Safety program and integrated safety analysis.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; (iv) Potential accident sequences caused by process deviations or other events internal to the... of occurrence of each potential accident sequence identified pursuant to paragraph (c)(1)(iv) of this... have experience in nuclear criticality safety, radiation safety, fire safety, and chemical process...

  13. Risk-Informed Safety Assurance and Probabilistic Assessment of Mission-Critical Software-Intensive Systems

    NASA Technical Reports Server (NTRS)

    Guarro, Sergio B.

    2010-01-01

    This report validates and documents the detailed features and practical application of the framework for software intensive digital systems risk assessment and risk-informed safety assurance presented in the NASA PRA Procedures Guide for Managers and Practitioner. This framework, called herein the "Context-based Software Risk Model" (CSRM), enables the assessment of the contribution of software and software-intensive digital systems to overall system risk, in a manner which is entirely compatible and integrated with the format of a "standard" Probabilistic Risk Assessment (PRA), as currently documented and applied for NASA missions and applications. The CSRM also provides a risk-informed path and criteria for conducting organized and systematic digital system and software testing so that, within this risk-informed paradigm, the achievement of a quantitatively defined level of safety and mission success assurance may be targeted and demonstrated. The framework is based on the concept of context-dependent software risk scenarios and on the modeling of such scenarios via the use of traditional PRA techniques - i.e., event trees and fault trees - in combination with more advanced modeling devices such as the Dynamic Flowgraph Methodology (DFM) or other dynamic logic-modeling representations. The scenarios can be synthesized and quantified in a conditional logic and probabilistic formulation. The application of the CSRM method documented in this report refers to the MiniAERCam system designed and developed by the NASA Johnson Space Center.

  14. Cannabis for therapeutic purposes and public health and safety: a systematic and critical review.

    PubMed

    Sznitman, Sharon R; Zolotov, Yuval

    2015-01-01

    The use of Cannabis for Therapeutic Purposes (CTP) has recently become legal in many places. These policy and legal modifications may be related to changes in cannabis perceptions, availability and use and in the way cannabis is grown and sold. This may in turn have effects on public health and safety. To better understand the potential effects of CTP legalization on public health and safety, the current paper synthesizes and critically discusses the relevant literature. Twenty-eight studies were identified by a comprehensive search strategy, and their characteristics and main findings were systematically reviewed according to the following content themes: CTP and illegal cannabis use; CTP and other public health issues; CTP, crime and neighbourhood disadvantage. The research field is currently limited by a lack of theoretical and methodological rigorous studies. The review shows that the most prevalent theme of investigation so far has been the relation between CTP and illegal cannabis use. In addition, the literature review shows that there is an absence of evidence to support many common concerns related to detrimental public health and safety effects of CTP legalization. Although lack of evidence provides some reassurance that CTP legalization may not have posed a substantial threat to public health and safety, this conclusion needs to be examined in light of the limitations of studies conducted so far. Furthermore, as CTP policy continues to evolve, including incorporation of greater commercialization, it is possible that the full effects of CTP legalization have yet to take place. Ensuring study quality will allow future research to better investigate the complex role that CTP plays in relation to society at large, and public health and safety in particular. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Biomedical Applications of Carbon Nanotubes: A Critical Review.

    PubMed

    Sharma, Priyanka; Mehra, Neelesh Kumar; Jain, Keerti; Jain, N K

    2016-08-01

    The convergence of nano and biotechnology is enabling scientific and technical knowledge for improving human well being. Carbon nanotubes have become most fascinating material to be studied and unveil new avenues in the field of nanobiotechnology. The nanometer size and high aspect ratio of the CNTs are the two distinct features, which have contributed to diverse biomedical applications. They have captured the attention as nanoscale materials due to their nanometric structure and remarkable list of superlative and extravagant properties that encouraged their exploitation for promising applications. Significant progress has been made in order to overcome some of the major hurdles towards biomedical application of nanomaterials, especially on issues regarding the aqueous solubility/dispersion and safety of CNTs. Functionalized CNTs have been used in drug targeting, imaging, and in the efficient delivery of gene and nucleic acids. CNTs have also demonstrated great potential in diverse biomedical uses like drug targeting, imaging, cancer treatment, tissue regeneration, diagnostics, biosensing, genetic engineering and so forth. The present review highlights the possible potential of CNTs in diagnostics, imaging and targeted delivery of bioactives and also outlines the future opportunities for biomedical applications.

  16. Regenerative braking strategies, vehicle safety and stability control systems: critical use-case proposals

    NASA Astrophysics Data System (ADS)

    Oleksowicz, Selim A.; Burnham, Keith J.; Southgate, Adam; McCoy, Chris; Waite, Gary; Hardwick, Graham; Harrington, Cian; McMurran, Ross

    2013-05-01

    The sustainable development of vehicle propulsion systems that have mainly focused on reduction of fuel consumption (i.e. CO2 emission) has led, not only to the development of systems connected with combustion processes but also to legislation and testing procedures. In recent years, the low carbon policy has made hybrid vehicles and fully electric vehicles (H/EVs) popular. The main virtue of these propulsion systems is their ability to restore some of the expended energy from kinetic movement, e.g. the braking process. Consequently new research and testing methods for H/EVs are currently being developed. This especially concerns the critical 'use-cases' for functionality tests within dynamic events for both virtual simulations, as well as real-time road tests. The use-case for conventional vehicles for numerical simulations and road tests are well established. However, the wide variety of tests and their great number (close to a thousand) creates a need for selection, in the first place, and the creation of critical use-cases suitable for testing H/EVs in both virtual and real-world environments. It is known that a marginal improvement in the regenerative braking ratio can significantly improve the vehicle range and, therefore, the economic cost of its operation. In modern vehicles, vehicle dynamics control systems play the principal role in safety, comfort and economic operation. Unfortunately, however, the existing standard road test scenarios are insufficient for H/EVs. Sector knowledge suggests that there are currently no agreed tests scenarios to fully investigate the effects of brake blending between conventional and regenerative braking as well as the regenerative braking interaction with active driving safety systems (ADSS). The paper presents seven manoeuvres, which are considered to be suitable and highly informative for the development and examination of H/EVs with regenerative braking capability. The critical manoeuvres presented are considered to be

  17. Effects of the Smartphone Application "Safe Patients" on Knowledge of Patient Safety Issues Among Surgical Patients.

    PubMed

    Cho, Sumi; Lee, Eunjoo

    2017-12-01

    Recently, the patient's role in preventing adverse events has been emphasized. Patients who are more knowledgeable about safety issues are more likely to engage in safety initiatives. Therefore, nurses need to develop techniques and tools that increase patients' knowledge in preventing adverse events. For this reason, an educational smartphone application for patient safety called "Safe Patients" was developed through an iterative process involving a literature review, expert consultations, and pilot testing of the application. To determine the effect of "Safe Patients," it was implemented for patients in surgical units in a tertiary hospital in South Korea. The change in patients' knowledge about patient safety was measured using seven true/false questions developed in this study. A one-group pretest and posttest design was used, and a total of 123 of 190 possible participants were tested. The percentage of correct answers significantly increased from 64.5% to 75.8% (P < .001) after implementation of the "Safe Patients" application. This study demonstrated that the application "Safe Patients" could effectively improve patients' knowledge of safety issues. This will ultimately empower patients to engage in safe practices and prevent adverse events related to surgery.

  18. Resilience Engineering in Critical Long Term Aerospace Software Systems: A New Approach to Spacecraft Software Safety

    NASA Astrophysics Data System (ADS)

    Dulo, D. A.

    Safety critical software systems permeate spacecraft, and in a long term venture like a starship would be pervasive in every system of the spacecraft. Yet software failure today continues to plague both the systems and the organizations that develop them resulting in the loss of life, time, money, and valuable system platforms. A starship cannot afford this type of software failure in long journeys away from home. A single software failure could have catastrophic results for the spaceship and the crew onboard. This paper will offer a new approach to developing safe reliable software systems through focusing not on the traditional safety/reliability engineering paradigms but rather by focusing on a new paradigm: Resilience and Failure Obviation Engineering. The foremost objective of this approach is the obviation of failure, coupled with the ability of a software system to prevent or adapt to complex changing conditions in real time as a safety valve should failure occur to ensure safe system continuity. Through this approach, safety is ensured through foresight to anticipate failure and to adapt to risk in real time before failure occurs. In a starship, this type of software engineering is vital. Through software developed in a resilient manner, a starship would have reduced or eliminated software failure, and would have the ability to rapidly adapt should a software system become unstable or unsafe. As a result, long term software safety, reliability, and resilience would be present for a successful long term starship mission.

  19. Health IT for Patient Safety and Improving the Safety of Health IT.

    PubMed

    Magrabi, Farah; Ong, Mei-Sing; Coiera, Enrico

    2016-01-01

    Alongside their benefits health IT applications can pose new risks to patient safety. Problems with IT have been linked to many different types of clinical errors including prescribing and administration of medications; as well as wrong-patient, wrong-site errors, and delays in procedures. There is also growing concern about the risks of data breach and cyber-security. IT-related clinical errors have their origins in processes undertaken to design, build, implement and use software systems in a broader sociotechnical context. Safety can be improved with greater standardization of clinical software and by improving the quality of processes at different points in the technology life cycle, spanning design, build, implementation and use in clinical settings. Oversight processes can be set up at a regional or national level to ensure that clinical software systems meet specific standards. Certification and regulation are two mechanisms to improve oversight. In the absence of clear standards, guidelines are useful to promote safe design and implementation practices. Processes to identify and mitigate hazards can be formalised via a safety management system. Minimizing new patient safety risks is critical to realizing the benefits of IT.

  20. Critical Drivers for Safety Culture: Examining Department of Energy and U.S. Army Operational Experiences - 12382

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowes, Elizabeth A.

    2012-07-01

    Evaluating operational incidents can provide a window into the drivers most critical to establishing and maintaining a strong safety culture, thereby minimizing the potential project risk associated with safety incidents. By examining U.S. Department of Energy (DOE) versus U.S. Army drivers in terms of regulatory and contract requirements, programs implemented to address the requirements, and example case studies of operational events, a view of the elements most critical to making a positive influence on safety culture is presented. Four case studies are used in this evaluation; two from DOE and two from U.S. Army experiences. Although the standards guiding operationsmore » at these facilities are different, there are many similarities in the level of hazards, as well as the causes and the potential consequences of the events presented. Two of the incidents examined, one from a DOE operation and the other from a U.S. Army facility, resulted in workers receiving chemical burns. The remaining two incidents are similar in that significant conduct of operations failures occurred resulting in high-level radioactive waste (in the case of the DOE facility) or chemical agent (in the case of the Army facility) being transferred outside of engineering controls. A review of the investigation reports for all four events indicates the primary causes to be failures in work planning leading to ineffective hazard evaluation and control, lack of procedure adherence, and most importantly, lack of management oversight to effectively reinforce expectations for safe work planning and execution. DOE and Army safety programs are similar, and although there are some differences in contractual requirements, the expectations for safe performance are essentially the same. This analysis concludes that instilling a positive safety culture comes down to management leadership and engagement to (1) cultivate an environment that values a questioning attitude and (2) continually reinforce

  1. Advanced vehicle dynamics of heavy trucks with the perspective of road safety

    NASA Astrophysics Data System (ADS)

    Trigell, Annika Stensson; Rothhämel, Malte; Pauwelussen, Joop; Kural, Karel

    2017-10-01

    This paper presents state-of-the art within advanced vehicle dynamics of heavy trucks with the perspective of road safety. The most common accidents with heavy trucks involved are truck against passenger cars. Safety critical situations are for example loss of control (such as rollover and lateral stability) and a majority of these occur during speed when cornering. Other critical situations are avoidance manoeuvre and road edge recovery. The dynamic behaviour of heavy trucks have significant differences compared to passenger cars and as a consequence, successful application of vehicle dynamic functions for enhanced safety of trucks might differ from the functions in passenger cars. Here, the differences between vehicle dynamics of heavy trucks and passenger cars are clarified. Advanced vehicle dynamics solutions with the perspective of road safety of trucks are presented, beginning with the topic vehicle stability, followed by the steering system, the braking system and driver assistance systems that differ in some way from that of passenger cars as well.

  2. Willingness to use mobile application for smartphone for improving road safety.

    PubMed

    Cardamone, Angelo Stephen; Eboli, Laura; Forciniti, Carmen; Mazzulla, Gabriella

    2016-01-01

    In the last few years mobile devices have reached a large amount of consumers in both developed and high-growth world economies. In 2013, 97% of the Italian population owns a mobile phone, and 62% owns a smartphone. Application software for mobile devices is largely proposed to consumers, and several mobile applications were oriented toward the improvement of road safety and road accident risk reduction. In this paper, we describe the results of a survey oriented to preventively investigate on the willingness to receive and/or to give information about road condition by means of mobile devices. Road users were informed about the characteristics of a mobile application, and then they were invited to complete a questionnaire. Experimental data were used for capturing road user attitudes toward the use of the smartphone to improve road safety, and to establish the preferences for the different features of the proposed mobile application. To this end, we choose to use the ordered probit model methodology. We demonstrate that the adopted methodology accounts for the differential impacts of the willingness to receive and/or to give information about road conditions on the overall willingness to receive and/or to give information through an application software for mobile devices.

  3. 76 FR 77589 - Office of Hazardous Materials Safety; Notice of Application for Special Permits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-13

    ... DC. commerce of radioactive materials without being subject to the requirements in 49 CFR 173.417(a... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Application for Special Permits AGENCY: Pipeline and Hazardous...

  4. 77 FR 36607 - Office of Hazardous Materials Safety Notice of Application for Special Permits

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... commerce of certain DOT Specification 20WC radioactive material packagings after October 1, 2008. (mode 1... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety Notice of Application for Special Permits AGENCY: Pipeline and Hazardous...

  5. Use of failure mode, effect and criticality analysis to improve safety in the medication administration process.

    PubMed

    Rodriguez-Gonzalez, Carmen Guadalupe; Martin-Barbero, Maria Luisa; Herranz-Alonso, Ana; Durango-Limarquez, Maria Isabel; Hernandez-Sampelayo, Paloma; Sanjurjo-Saez, Maria

    2015-08-01

    To critically evaluate the causes of preventable adverse drug events during the nurse medication administration process in inpatient units with computerized prescription order entry and profiled automated dispensing cabinets in order to prioritize interventions that need to be implemented and to evaluate the impact of specific interventions on the criticality index. This is a failure mode, effects and criticality analysis (FMECA) study. A multidisciplinary consensus committee composed of pharmacists, nurses and doctors evaluated the process of administering medications in a hospital setting in Spain. By analysing the process, all failure modes were identified and criticality was determined by rating severity, frequency and likelihood of failure detection on a scale of 1 to 10, using adapted versions of already published scales. Safety strategies were identified and prioritized. Through consensus, the committee identified eight processes and 40 failure modes, of which 20 were classified as high risk. The sum of the criticality indices was 5254. For the potential high-risk failure modes, 21 different potential causes were found resulting in 24 recommendations. Thirteen recommendations were prioritized and developed over a 24-month period, reducing total criticality from 5254 to 3572 (a 32.0% reduction). The recommendations with a greater impact on criticality were the development of an electronic medication administration record (-582) and the standardization of intravenous drug compounding in the unit (-168). Other improvements, such as barcode medication administration technology (-1033), were scheduled for a longer period of time because of lower feasibility. FMECA is a useful approach that can improve the medication administration process. © 2015 John Wiley & Sons, Ltd.

  6. Quality and Safety Education for Nurses (QSEN): The Key is Systems Thinking.

    PubMed

    Dolansky, Mary A; Moore, Shirley M

    2013-09-30

    Over a decade has passed since the Institute of Medicine's reports on the need to improve the American healthcare system, and yet only slight improvement in quality and safety has been reported. The Quality and Safety Education for Nurses (QSEN) initiative was developed to integrate quality and safety competencies into nursing education. The current challenge is for nurses to move beyond the application of QSEN competencies to individual patients and families and incorporate systems thinking in quality and safety education and healthcare delivery. This article provides a history of QSEN and proposes a framework in which systems thinking is a critical aspect in the application of the QSEN competencies. We provide examples of how using this framework expands nursing focus from individual care to care of the system and propose ways to teach and measure systems thinking. The conclusion calls for movement from personal effort and individual care to a focus on care of the system that will accelerate improvement of healthcare quality and safety.

  7. Transit vehicle-to-infrastructure (V2I) applications : near term research and development transit bus stop pedestrian safety application : operational concept.

    DOT National Transportation Integrated Search

    2014-12-01

    This document serves as an Operational Concept for the Transit Bus Stop Pedestrian Safety application. The purpose of this document is to communicate user needs and desired capabilities for and expectations of the Transit Bus Stop Pedestrian Safety a...

  8. Critical, sustainable and threshold fluxes for membrane filtration with water industry applications.

    PubMed

    Field, Robert W; Pearce, Graeme K

    2011-05-11

    Critical flux theory evolved as a description of the upper bound in the operating envelope for controlled steady state environments such as cross-flow systems. However, in the application of UF membranes in the water industry, dead-end (direct-flow) designs are used. Direct-flow is a pseudo steady state operation with different fouling characteristics to cross-flow, and thus the critical flux concept has limited applicability. After a review of recent usage of the critical flux theory, an alternative concept for providing design guidelines for direct-flow systems namely that of the threshold flux is introduced. The concept of threshold flux can also be applicable to cross-flow systems. In more general terms the threshold flux can be taken to be the flux that divides a low fouling region from a high fouling region. This may be linked both to the critical flux concept and to the concept of a sustainable flux. The sustainable flux is the one at which a modest degree of fouling occurs, providing a compromise between capital expenditure (which is reduced by using high flux) and operating costs (which are reduced by restricting the fouling rate). Whilst the threshold flux can potentially be linked to physical phenomena alone, the sustainable flux also depends upon economic factors and is thus of a different nature to the critical and threshold fluxes. This distinction will be illustrated using some MBR data. Additionally the utility of the concept of a threshold flux will be illustrated using pilot plant data obtained for UF treatment of four sources of water. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. 49 CFR Appendix B to Part 385 - Explanation of Safety Rating Process

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-employment controlled substance test result (critical). § 382.303(a)Failing to conduct post accident testing... controls in place that function effectively to ensure acceptable compliance with the applicable safety... are those identified as such where noncompliance relates to management and/or operational controls...

  10. 49 CFR Appendix B to Part 385 - Explanation of Safety Rating Process

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-employment controlled substance test result (critical). § 382.303(a)Failing to conduct post accident testing... controls in place that function effectively to ensure acceptable compliance with the applicable safety... are those identified as such where noncompliance relates to management and/or operational controls...

  11. Retrieval of radiology reports citing critical findings with disease-specific customization.

    PubMed

    Lacson, Ronilda; Sugarbaker, Nathanael; Prevedello, Luciano M; Ivan, Ip; Mar, Wendy; Andriole, Katherine P; Khorasani, Ramin

    2012-01-01

    Communication of critical results from diagnostic procedures between caregivers is a Joint Commission national patient safety goal. Evaluating critical result communication often requires manual analysis of voluminous data, especially when reviewing unstructured textual results of radiologic findings. Information retrieval (IR) tools can facilitate this process by enabling automated retrieval of radiology reports that cite critical imaging findings. However, IR tools that have been developed for one disease or imaging modality often need substantial reconfiguration before they can be utilized for another disease entity. THIS PAPER: 1) describes the process of customizing two Natural Language Processing (NLP) and Information Retrieval/Extraction applications - an open-source toolkit, A Nearly New Information Extraction system (ANNIE); and an application developed in-house, Information for Searching Content with an Ontology-Utilizing Toolkit (iSCOUT) - to illustrate the varying levels of customization required for different disease entities and; 2) evaluates each application's performance in identifying and retrieving radiology reports citing critical imaging findings for three distinct diseases, pulmonary nodule, pneumothorax, and pulmonary embolus. Both applications can be utilized for retrieval. iSCOUT and ANNIE had precision values between 0.90-0.98 and recall values between 0.79 and 0.94. ANNIE had consistently higher precision but required more customization. Understanding the customizations involved in utilizing NLP applications for various diseases will enable users to select the most suitable tool for specific tasks.

  12. Safety and efficacy of autologous cell therapy in critical limb ischemia: a systematic review.

    PubMed

    Benoit, Eric; O'Donnell, Thomas F; Patel, Amit N

    2013-01-01

    Researchers have accumulated a decade of experience with autologous cell therapy in the treatment of critical limb ischemia (CLI). We conducted a systematic review of clinical trials in the literature to determine the safety and efficacy of cell therapy in CLI. We searched the literature for clinical trials of autologous cell therapy in CLI, including observational series of five or more patients to accrue a large pool of patients for safety analysis. Safety analysis included evaluation of death, cancer, unregulated angiogenesis, and procedural adverse events such as bleeding. Efficacy analysis included the clinical endpoints amputation and death as well as functional and surrogate endpoints. We identified 45 clinical trials, including seven RCTs, and 1,272 patients who received cell therapy. The overall adverse event rate was low (4.2%). Cell therapy patients did not have a higher mortality rate than control patients and demonstrated no increase in cancer incidence when analyzed against population rates. With regard to efficacy, cell therapy patients had a significantly lower amputation rate than control patients (OR 0.36, p = 0.0004). Cell therapy also demonstrated efficacy in a variety of functional and surrogate outcomes. Clinical trials differed in the proportion of patients with risk factors for clinical outcomes, and these influenced rates of amputation and death. Cell therapy presents a favorable safety profile with a low adverse event rate and no increase in severe events such as mortality and cancer and treatment with cell therapy decreases the risk of amputation. Cell therapy has a positive benefit-to-risk ratio in CLI and may be a valuable treatment option, particularly for those challenging patients who cannot undergo arterial reconstruction.

  13. Safety leadership: application in construction site.

    PubMed

    Cooper, Dominic

    2010-01-01

    The extant safety literature suggests that managerial Safety Leadership is vital to the success and maintenance of a behavioral safety process. The current paper explores the role of Managerial Safety Leadership behaviors in the success of a behavioral safety intervention in the Middle-East with 47,000 workers from multiple nationalities employed by fourteen sub-contractors and one main contractor. A quasi-experimental repeating ABABAB, within groups design was used. Measurement focused on managerial Safety Leadership and employee safety behaviors as well as Corrective Actions. Data was collected over 104 weeks. During this time, results show safety behavior improved by 30 percentage points from an average of 65% during baseline to an average of 95%. The site achieved 121 million man-hours free of lost-time injuries on the longest run. Stepwise multiple regression analyses indicated 86% of the variation in employee safety behavior was associated with senior, middle and front-line manager's Safety Leadership behaviors and the Corrective Action Rate. Approximately 38% of the variation in the Total Recordable Incident Rate (TRIR) was associated with the Observation rate, Corrective Action Rate and Observers Records of managerial safety leaders (Visible Ongoing Support). The results strongly suggest manager's Safety Leadership influences the success of Behavioral Safety processes.

  14. Implementation of a critical incident reporting system in a neurosurgical department.

    PubMed

    Kantelhardt, P; Müller, M; Giese, A; Rohde, V; Kantelhardt, S R

    2011-02-01

    Critical incident monitoring is an important tool for quality improvement and the maintenance of high safety standards. It was developed for aviation safety and is now widely accepted as a useful tool to reduce medical care-related morbidity and mortality. Despite this widespread acceptance, the literature has no reports on any neurosurgical applications of critical incident monitoring. We describe the introduction of a mono-institutional critical incident reporting system in a neurosurgical department. Furthermore, we have developed a formula to assess possible counterstrategies. All staff members of a neurosurgical department were advised to report critical incidents. The anonymous reporting form contained a box for the description of the incident, several multiple-choice questions on specific risk factors, place and reason for occurrence of the incident, severity of the consequences and suggested counterstrategies. The incident data was entered into an online documentation system (ADKA DokuPik) and evaluated by an external specialist. For data analysis we applied a modified assessment scheme initially designed for flight safety. Data collection was started in September 2008. The average number of reported incidents was 18 per month (currently 216 in total). Most incidents occurred on the neurosurgical ward (64%). Human error was involved in 86% of the reported incidents. The largest group of incidents consisted of medication-related problems. Accordingly, counterstrategies were developed, resulting in a decrease in the relative number of reported medication-related incidents from 42% (March 09) to 30% (September 09). Implementation of the critical incident reporting system presented no technical problems. The reporting rate was high compared to that reported in the current literature. The formulation, evaluation and introduction of specific counterstrategies to guard against selected groups of incidents may improve patient safety in neurosurgical departments.

  15. Criticality Safety Controls for 55-Gallon Drums with a Mass Limit of 200 grams Pu-239

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chou, P

    The following 200-gram Pu drum criticality safety controls are applicable to RHWM drum storage operations: (1) Mass (Fissile/Pu) - each 55-gallon drum or its equivalent shall be limited to 200 gram Pu or Pu equivalent; (2) Moderation - Hydrogen materials with a hydrogen density greater than that (0.133 g H/cc) of polyethylene and paraffin are not allowed and hydrogen materials with a hydrogen density no greater than that of polyethylene and paraffin are allowed with unlimited amounts; (3) Interaction - a spacing of 30-inches (76 cm) is required between arrays and 200-gram Pu drums shall be placed in arrays formore » 200-gram Pu drums only (no mingling of 200-gram Pu drums with other drums not meeting the drum controls associated with the 200-gram limit); (4) Reflection - no beryllium and carbon/graphite (other than the 50-gram waiver amount) is allowed, (note that Nat-U exceeding the waiver amount is allowed when its U-235 content is included in the fissile mass limit of 200 grams); and (5) Geometry - drum geometry, only 55-gallon drum or its equivalent shall be used and array geometry, 55-gallon drums are allowed for 2-high stacking. Steel waste boxes may be stacked 3-high if constraint.« less

  16. Y-12 PLANT NUCLEAR SAFETY HANDBOOK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wachter, J.W. ed.; Bailey, M.L.; Cagle, T.J.

    1963-03-27

    Information needed to solve nuclear safety problems is condensed into a reference book for use by persons familiar with the field. Included are a glossary of terms; useful tables; nuclear constants; criticality calculations; basic nuclear safety limits; solution geometries and critical values; metal critical values; criticality values for intermediate, heterogeneous, and interacting systems; miscellaneous and related information; and report number, author, and subject indexes. (C.H.)

  17. New Developments in Error Detection and Correction Strategies for Critical Applications

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; LaBel, Ken

    2016-01-01

    The presentation will cover a variety of mitigation strategies that were developed for critical applications. An emphasis is placed on strengths and weaknesses per mitigation technique as it pertains to different FPGA device types.

  18. Managing Risk in Safety Critical Operations - Lessons Learned from Space Operations

    NASA Technical Reports Server (NTRS)

    Gonzalez, Steven A.

    2002-01-01

    The Mission Control Center (MCC) at Johnson Space Center (JSC) has a rich legacy of supporting Human Space Flight operations throughout the Apollo, Shuttle and International Space Station eras. Through the evolution of ground operations and the Mission Control Center facility, NASA has gained a wealth of experience of what it takes to manage the risk in Safety Critical Operations, especially when human life is at risk. The focus of the presentation will be on the processes (training, operational rigor, team dynamics) that enable the JSC/MCC team to be so successful. The presentation will also share the evolution of the Mission Control Center architecture and how the evolution was introduced while managing the risk to the programs supported by the team. The details of the MCC architecture (e.g., the specific software, hardware or tools used in the facility) will not be shared at the conference since it would not give any additional insight as to how risk is managed in Space Operations.

  19. Bounding criticality safety analyses for shipments of unconfigured spent nuclear fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lichtenwalter, J.J.; Parks, C.V.

    1998-06-01

    In November 1996, a request was made to the US Department of Energy for a waiver for three shipments of spent nuclear fuel (SNF) from Oak Ridge National Laboratory (ORNL) to the Savannah River Site (SRS) in the US NRC certified BMI-1 cask (CoC 5957). Although the post-irradiation fissile mass (based on chemical assays) in each shipment was less than 800 g, a criticality safety analysis was needed because the pre-irradiation mass exceeded 800 g, the fissile material limit in the CoC. The analyses were performed on SNF consisting of aluminum-clad U{sub 3}O{sub 8}, UAl{sub x}, and U{sub 3}Si{sub 2}more » plates, fragments and pieces that had been irradiated at ORNL during the Reduced Enrichment Research and Test Reactor Program of the 1980s. The highlights of the approach used to analyze this unique SNF and the benefits of the waiver are presented in this paper.« less

  20. Expressions of cultural safety in public health nursing practice.

    PubMed

    Richardson, Anna; Yarwood, Judy; Richardson, Sandra

    2017-01-01

    Cultural safety is an essential concept within New Zealand nursing that is formally linked to registration and competency-based practice certification. Despite its centrality to New Zealand nursing philosophies and the stated expectation of cultural safety as a practice element, there is limited evidence of its application in the literature. This research presents insight into public health nurse's (PHN) experiences, demonstrating the integration of cultural safety principles into practice. These findings emerged following secondary analysis of data from a collaborative, educative research project where PHNs explored the use of family assessment tools. In particular, the 15-minute interview tool was introduced and used by the PHNs when working with families. Critical analysis of transcribed data from PHN interviews, utilising a cultural safety lens, illuminated practical ways in which cultural safety concepts infused PHN practice with families. The themes that emerged reflected the interweaving of the principles of cultural safety with the application of the five components of the 15-minute interview. This highlights elements of PHN work with individuals and families not previously acknowledged. Examples of culturally safe nursing practice resonated throughout the PHN conversations as they grappled with the increasing complexity of working with a diverse range of families. © 2016 John Wiley & Sons Ltd.

  1. Protection and Safety.

    ERIC Educational Resources Information Center

    American School Board Journal, 1964

    1964-01-01

    Several aspects of school safety and protection are presented for school administrators and architects. Among those topics discussed are--(1) life safety, (2) vandalism controlled through proper design, (3) personal protective devices, and (4) fire alarm systems. Another critical factor in providing a complete school safety program is proper…

  2. Application Agreement and Integration Services

    NASA Technical Reports Server (NTRS)

    Driscoll, Kevin R.; Hall, Brendan; Schweiker, Kevin

    2013-01-01

    Application agreement and integration services are required by distributed, fault-tolerant, safety critical systems to assure required performance. An analysis of distributed and hierarchical agreement strategies are developed against the backdrop of observed agreement failures in fielded systems. The documented work was performed under NASA Task Order NNL10AB32T, Validation And Verification of Safety-Critical Integrated Distributed Systems Area 2. This document is intended to satisfy the requirements for deliverable 5.2.11 under Task 4.2.2.3. This report discusses the challenges of maintaining application agreement and integration services. A literature search is presented that documents previous work in the area of replica determinism. Sources of non-deterministic behavior are identified and examples are presented where system level agreement failed to be achieved. We then explore how TTEthernet services can be extended to supply some interesting application agreement frameworks. This document assumes that the reader is familiar with the TTEthernet protocol. The reader is advised to read the TTEthernet protocol standard [1] before reading this document. This document does not re-iterate the content of the standard.

  3. Towards a Food Safety Knowledge Base Applicable in Crisis Situations and Beyond.

    PubMed

    Falenski, Alexander; Weiser, Armin A; Thöns, Christian; Appel, Bernd; Käsbohrer, Annemarie; Filter, Matthias

    2015-01-01

    In case of contamination in the food chain, fast action is required in order to reduce the numbers of affected people. In such situations, being able to predict the fate of agents in foods would help risk assessors and decision makers in assessing the potential effects of a specific contamination event and thus enable them to deduce the appropriate mitigation measures. One efficient strategy supporting this is using model based simulations. However, application in crisis situations requires ready-to-use and easy-to-adapt models to be available from the so-called food safety knowledge bases. Here, we illustrate this concept and its benefits by applying the modular open source software tools PMM-Lab and FoodProcess-Lab. As a fictitious sample scenario, an intentional ricin contamination at a beef salami production facility was modelled. Predictive models describing the inactivation of ricin were reviewed, relevant models were implemented with PMM-Lab, and simulations on residual toxin amounts in the final product were performed with FoodProcess-Lab. Due to the generic and modular modelling concept implemented in these tools, they can be applied to simulate virtually any food safety contamination scenario. Apart from the application in crisis situations, the food safety knowledge base concept will also be useful in food quality and safety investigations.

  4. Transit vehicle-to-infrastructure (V2I) applications : near term research and development. Transit bus-pedestrian/cyclist crossing safety application : operational concept.

    DOT National Transportation Integrated Search

    2013-11-01

    This document serves as an Operational Concept for the Transit Bus-Pedestrian/Cyclist Crossing Safety application. The purpose of this document is to provide an operational description of how the Transit Bus-Pedestrian/Cyclist Crossing Safety W...

  5. Fire safety applications for spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Olson, Sandra L.

    1989-01-01

    Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.

  6. Commercial-off-the-shelf (COTS) hardware and software for train control applications : system safety considerations.

    DOT National Transportation Integrated Search

    2003-04-01

    The objective of this study was to assess the feasibility of using commercial off-the-shelf(COTS)processor-based systems for safety- related railroad applications. From the safety perspective,the fundamental challenges of using COTS products are most...

  7. New Developments in Error Detection and Correction Strategies for Critical Applications

    NASA Technical Reports Server (NTRS)

    Berg, Melanie; Label, Ken

    2017-01-01

    The presentation will cover a variety of mitigation strategies that were developed for critical applications. An emphasis is placed on strengths and weaknesses per mitigation technique as it pertains to different Field programmable gate array (FPGA) device types.

  8. Designing Crane Controls with Applied Mechanical and Electrical Safety Features

    NASA Technical Reports Server (NTRS)

    Lytle, Bradford P.; Walczak, Thomas A.

    2002-01-01

    The use of overhead traveling bridge cranes in many varied applications is common practice. In particular, the use of cranes in the nuclear, military, commercial, aerospace, and other industries can involve safety critical situations. Considerations for Human Injury or Casualty, Loss of Assets, Endangering the Environment, or Economic Reduction must be addressed. Traditionally, in order to achieve additional safety in these applications, mechanical systems have been augmented with a variety of devices. These devices assure that a mechanical component failure shall reduce the risk of a catastrophic loss of the correct and/or safe load carrying capability. ASME NOG-1-1998, (Rules for Construction of Overhead and Gantry Cranes, Top Running Bridge, and Multiple Girder), provides design standards for cranes in safety critical areas. Over and above the minimum safety requirements of todays design standards, users struggle with obtaining a higher degree of reliability through more precise functional specifications while attempting to provide "smart" safety systems. Electrical control systems also may be equipped with protective devices similar to the mechanical design features. Demands for improvement of the cranes "control system" is often recognized, but difficult to quantify for this traditionally "mechanically" oriented market. Finite details for each operation must be examined and understood. As an example, load drift (or small motions) at close tolerances can be unacceptable (and considered critical). To meet these high functional demands encoders and other devices are independently added to control systems to provide motion and velocity feedback to the control drive. This paper will examine the implementation of Programmable Electronic Systems (PES). PES is a term this paper will use to describe any control system utilizing any programmable electronic device such as Programmable Logic Controllers (PLC), or an Adjustable Frequency Drive (AID) 'smart' programmable

  9. Evaluation of Design Assurance Regulations for Safety of Space Navigation Services

    NASA Astrophysics Data System (ADS)

    Ratti, B.; Sarno, M.; De Andreis, C.

    2005-12-01

    The European Space Agency (ESA), the European Community (EC), and the European Organisation for the Safety of Air Navigation (Eurocontrol) are contributing to the development of a Global positioning and Navigation Satellite System, known as GNSS. The development programme is carried out in two main steps:• GNSS-1: the first-generation system, based on signals received from the GPS (USA) and GLONASS (Russia) constellations, and augmentation systems like EGNOS (European Geostationary Navigation Overlay Service)• GNSS-2: the second-generation system, that will achieve the ultimate objective of European sovereignty for position determination, navigation and time dissemination. This system, named Galileo, comprises a global space and ground control infrastructure.The Galileo navigation signal will be used in the frame of safety-critical transport applications, thus it is necessary to assess the space safety assurance activity against the civil safety regulations and safety management system.. RTCA DO-254 and IEC 61508 standards, considered as part of best practice engineering references, for the development of safety- related systems in most applications, were selected during phases B2 and C0 of the Galileo project for this purpose.

  10. 75 FR 5167 - Office of Hazardous Materials Safety; Notice of Delays In Processing of Special Permits Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-01

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Delays In Processing of Special Permits Applications AGENCY: Pipeline..., Office of Hazardous Materials Special Permits and Approvals, Pipeline and Hazardous Materials Safety...

  11. 75 FR 78800 - Office of Hazardous Materials Safety; Notice of Delays in Processing of Special Permits Applications

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-16

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration Office of Hazardous Materials Safety; Notice of Delays in Processing of Special Permits Applications AGENCY: Pipeline..., Office of Hazardous Materials Special Permits and Approvals, Pipeline and Hazardous Materials Safety...

  12. Model Transformation for a System of Systems Dependability Safety Case

    NASA Technical Reports Server (NTRS)

    Murphy, Judy; Driskell, Stephen B.

    2010-01-01

    Software plays an increasingly larger role in all aspects of NASA's science missions. This has been extended to the identification, management and control of faults which affect safety-critical functions and by default, the overall success of the mission. Traditionally, the analysis of fault identification, management and control are hardware based. Due to the increasing complexity of system, there has been a corresponding increase in the complexity in fault management software. The NASA Independent Validation & Verification (IV&V) program is creating processes and procedures to identify, and incorporate safety-critical software requirements along with corresponding software faults so that potential hazards may be mitigated. This Specific to Generic ... A Case for Reuse paper describes the phases of a dependability and safety study which identifies a new, process to create a foundation for reusable assets. These assets support the identification and management of specific software faults and, their transformation from specific to generic software faults. This approach also has applications to other systems outside of the NASA environment. This paper addresses how a mission specific dependability and safety case is being transformed to a generic dependability and safety case which can be reused for any type of space mission with an emphasis on software fault conditions.

  13. [Learning from aviation - how to increase patient safety in surgery].

    PubMed

    Renz, B; Angele, M K; Jauch, K-W; Kasparek, M S; Kreis, M; Müller, M H

    2012-04-01

    During the last years attempts have been made to draw lessons from aviation to increase patient safety in medicine. In particular similar conditions are present in surgery as pilots and surgeons may have to support high physical and mental pressure. The use of a few safety instruments from aviation is feasible in an attempt to increase safety in surgery. First a "root caused" accident research may be established. This is achievable by morbidity and mortality conferences and critical incident reporting systems (CIRS). Second, standard operating procedures may assure a uniform mental model of team members. Furthermore, crew resource management illustrates a strategy and attitude concept, which is applicable in all situations. Safety instruments from aviation, therefore, seem to have a high potential to increase safety in surgery when properly employed. © Georg Thieme Verlag KG Stuttgart ˙ New York.

  14. Microfabricated Chemical Sensors for Safety and Emission Control Applications

    NASA Technical Reports Server (NTRS)

    Hunter, G. W.; Neudeck, P. G.; Chen, L.-Y.; Knight, D.; Liu, C. C.; Wu, Q. H.

    1998-01-01

    Chemical sensor technology is being developed for leak detection, emission monitoring, and fire safety applications. The development of these sensors is based on progress in two types of technology: 1) Micromachining and microfabrication (MicroElectroMechanical Systems (MEMS)-based) technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Using these technologies, sensors to measure hydrogen, hydrocarbons, nitrogen oxides, carbon monoxide, oxygen, and carbon dioxide are being developed. A description is given of each sensor type and its present stage of development. It is concluded that microfabricated sensor technology has significant potential for use in a range of aerospace applications.

  15. Deriving Safety Cases from Automatically Constructed Proofs

    NASA Technical Reports Server (NTRS)

    Basir, Nurlida; Denney, Ewen; Fischer, Bernd

    2009-01-01

    Formal proofs provide detailed justification for the validity of claims and are widely used in formal software development methods. However, they are often complex and difficult to understand, because the formalism in which they are constructed and encoded is usually machine-oriented, and they may also be based on assumptions that are not justified. This causes concerns about the trustworthiness of using formal proofs as arguments in safety-critical applications. Here, we present an approach to develop safety cases that correspond to formal proofs found by automated theorem provers and reveal the underlying argumentation structure and top-level assumptions. We concentrate on natural deduction style proofs, which are closer to human reasoning than resolution proofs, and show how to construct the safety cases by covering the natural deduction proof tree with corresponding safety case fragments. We also abstract away logical book-keeping steps, which reduces the size of the constructed safety cases. We show how the approach can be applied to the proofs found by the Muscadet prover.

  16. Critical Care Ultrasound: A Review for Practicing Nephrologists.

    PubMed

    Wilson, Jennifer G; Breyer, Kristine E W

    2016-05-01

    The use of point-of-care ultrasound in the intensive care unit, both for diagnostic and procedural purposes, has rapidly proliferated, and evidence supporting its use is growing. Conceptually, critical care ultrasound (CCUS) should be considered an extension of the physical examination and should not be considered a replacement for formal echocardiography or radiology-performed ultrasound. Several CCUS applications are of particular relevance to nephrologists, including focused renal ultrasound in patients at high risk for urinary tract obstruction, real-time ultrasound guidance and verification during the placement of central venous catheters, and ultrasound-augmented assessment of shock and volume status. Each of these applications has the capacity to improve outcomes in patients with acute kidney injury. Although robust evidence regarding long-term outcomes is lacking, existing data demonstrate that CCUS has the potential to improve diagnostic accuracy, expedite appropriate management, and increase safety for critically ill patients across a spectrum of pathologies. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  17. Understanding safety-critical interactions with a home medical device through Distributed Cognition.

    PubMed

    Rajkomar, Atish; Mayer, Astrid; Blandford, Ann

    2015-08-01

    As healthcare shifts from the hospital to the home, it is becoming increasingly important to understand how patients interact with home medical devices, to inform the safe and patient-friendly design of these devices. Distributed Cognition (DCog) has been a useful theoretical framework for understanding situated interactions in the healthcare domain. However, it has not previously been applied to study interactions with home medical devices. In this study, DCog was applied to understand renal patients' interactions with Home Hemodialysis Technology (HHT), as an example of a home medical device. Data was gathered through ethnographic observations and interviews with 19 renal patients and interviews with seven professionals. Data was analyzed through the principles summarized in the Distributed Cognition for Teamwork methodology. In this paper we focus on the analysis of system activities, information flows, social structures, physical layouts, and artefacts. By explicitly considering different ways in which cognitive processes are distributed, the DCog approach helped to understand patients' interaction strategies, and pointed to design opportunities that could improve patients' experiences of using HHT. The findings highlight the need to design HHT taking into consideration likely scenarios of use in the home and of the broader home context. A setting such as home hemodialysis has the characteristics of a complex and safety-critical socio-technical system, and a DCog approach effectively helps to understand how safety is achieved or compromised in such a system. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  18. 76 FR 38597 - Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-01

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration 49 CFR Parts 383 and 390 [Docket No. FMCSA-2011-0146] Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators of Certain Farm Vehicles and Off-Road Agricultural Equipment AGENCY: Federal Motor...

  19. 76 FR 50433 - Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-15

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration 49 CFR Parts 383 and 390 [Docket No. FMCSA-2011-0146] Regulatory Guidance: Applicability of the Federal Motor Carrier Safety Regulations to Operators of Certain Farm Vehicles and Off-Road Agricultural Equipment AGENCY: Federal Motor...

  20. Potential applications of video technology for traffic management and safety in Alabama

    DOT National Transportation Integrated Search

    2002-11-25

    Video technology applications for traffic management and safety are being implemented by state and local government agencies in Alabama. This technology offers both tangible and intangible benefits. Although video technology provides many benefits, i...

  1. Towards a Food Safety Knowledge Base Applicable in Crisis Situations and Beyond

    PubMed Central

    Falenski, Alexander; Weiser, Armin A.; Thöns, Christian; Appel, Bernd; Käsbohrer, Annemarie; Filter, Matthias

    2015-01-01

    In case of contamination in the food chain, fast action is required in order to reduce the numbers of affected people. In such situations, being able to predict the fate of agents in foods would help risk assessors and decision makers in assessing the potential effects of a specific contamination event and thus enable them to deduce the appropriate mitigation measures. One efficient strategy supporting this is using model based simulations. However, application in crisis situations requires ready-to-use and easy-to-adapt models to be available from the so-called food safety knowledge bases. Here, we illustrate this concept and its benefits by applying the modular open source software tools PMM-Lab and FoodProcess-Lab. As a fictitious sample scenario, an intentional ricin contamination at a beef salami production facility was modelled. Predictive models describing the inactivation of ricin were reviewed, relevant models were implemented with PMM-Lab, and simulations on residual toxin amounts in the final product were performed with FoodProcess-Lab. Due to the generic and modular modelling concept implemented in these tools, they can be applied to simulate virtually any food safety contamination scenario. Apart from the application in crisis situations, the food safety knowledge base concept will also be useful in food quality and safety investigations. PMID:26247028

  2. Developing a 'critical' approach to patient and public involvement in patient safety in the NHS: learning lessons from other parts of the public sector?

    PubMed

    Ocloo, Josephine E; Fulop, Naomi J

    2012-12-01

    There has been considerable momentum within the NHS over the last 10 years to develop greater patient and public involvement (PPI). This commitment has been reflected in numerous policy initiatives. In patient safety, the drive to increase involvement has increasingly been seen as an important way of building a safety culture. Evidence suggests, however, that progress has been slow and even more variable than in health care generally. Given this context, the paper analyses some of the key underlying drivers for involvement in the wider context of health and social care and makes some suggestions on what lessons can be learned for developing the PPI agenda in patient safety. To develop PPI further, it is argued that a greater understanding is needed of the contested nature of involvement in patient safety and how this has similarities to the emergence of user involvement in other parts of the public services. This understanding has led to the development of a range of critical theories to guide involvement that also make more explicit the underlying factors that support and hinder involvement processes, often related to power inequities and control. Achieving greater PPI in patient safety is therefore seen to require a more critical framework for understanding processes of involvement that can also help guide and evaluate involvement practices. © 2011 Blackwell Publishing Ltd.

  3. Microprocessor-based control systems application in nuclear power plant critical systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shah, M.R.; Nowak, J.B.

    Microprocessor-based control systems have been used in fossil power plants and are receiving greater acceptance for application in nuclear plants. This technology is not new but it does require unique considerations when applied to nuclear power plants. Sargent and Lundy (S and L) has used a microprocessor-based component logic control system (interposing Logic System) for safety- and non-safety-related components in nuclear power plants under construction overseas. Currently, S and L is in the design stage to replace an existing analog control system with a microprocessor-based control system in the U.S. The trend in the industry is to replace systems inmore » existing plants or design new power plants with microprocessor-based control systems.« less

  4. A Silent Safety Program

    NASA Technical Reports Server (NTRS)

    Goodin, James Ronald

    2006-01-01

    NASA's Columbia Accident Investigation Board (CAIB) referred 8 times to the NASA "Silent Safety Program." This term, "Silent Safety Program" was not an original observation but first appeared in the Rogers Commission's Investigation of the Challenger Mishap. The CAIB on page 183 of its report in the paragraph titled 'Encouraging Minority Opinion,' stated "The Naval Reactor Program encourages minority opinions and "bad news." Leaders continually emphasize that when no minority opinions are present, the responsibility for a thorough and critical examination falls to management. . . Board interviews revealed that it is difficult for minority and dissenting opinions to percolate up through the agency's hierarchy. . ." The first question and perhaps the only question is - what is a silent safety program? Well, a silent safety program may be the same as the dog that didn't bark in Sherlock Holmes' "Adventure of the Silver Blaze" because system safety should behave as a devil's advocate for the program barking on every occasion to insure a critical review inclusion. This paper evaluates the NASA safety program and provides suggestions to prevent the recurrence of the silent safety program alluded to in the Challenger Mishap Investigation. Specifically targeted in the CAM report, "The checks and balances the safety system was meant to provide were not working." A silent system safety program is not unique to NASA but could emerge in any and every organization. Principles developed by Irving Janis in his book, Groupthink, listed criteria used to evaluate an organization's cultural attributes that allows a silent safety program to evolve. If evidence validates Jams's criteria, then Jams's recommendations for preventing groupthink can also be used to improve a critical evaluation and thus prevent the development of a silent safety program.

  5. Final Technical Report on Quantifying Dependability Attributes of Software Based Safety Critical Instrumentation and Control Systems in Nuclear Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smidts, Carol; Huang, Funqun; Li, Boyuan

    With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems have significantly increased. The sophisticated nature and increasing complexity of software raises trust in these systems as a significant challenge. The trust placed in a software system is typically termed software dependability. Software dependability analysis faces uncommon challenges since software systems’ characteristics differ from those of hardware systems. The lack of systematic science-based methods for quantifying the dependability attributes in software-based instrumentation as well as control systems in safety critical applications has proved itself to be amore » significant inhibitor to the expanded use of modern digital technology in the nuclear industry. Dependability refers to the ability of a system to deliver a service that can be trusted. Dependability is commonly considered as a general concept that encompasses different attributes, e.g., reliability, safety, security, availability and maintainability. Dependability research has progressed significantly over the last few decades. For example, various assessment models and/or design approaches have been proposed for software reliability, software availability and software maintainability. Advances have also been made to integrate multiple dependability attributes, e.g., integrating security with other dependability attributes, measuring availability and maintainability, modeling reliability and availability, quantifying reliability and security, exploring the dependencies between security and safety and developing integrated analysis models. However, there is still a lack of understanding of the dependencies between various dependability attributes as a whole and of how such dependencies are formed. To address the need for quantification and give a more objective basis to the review process -- therefore reducing regulatory

  6. University Applicants' Critical Thinking Skills: The Case of the Finnish Educational Sciences

    ERIC Educational Resources Information Center

    Utriainen, Jukka; Marttunen, Miika; Kallio, Eeva; Tynjälä, Päivi

    2017-01-01

    This study investigates the quality of the critical thinking skills of applicants (n = 77) seeking entry to the faculty of educational sciences in a Finnish university and how these skills are associated with the applicant's age, previous higher education experience, and matriculation and entrance examination scores. The data consist of the…

  7. Guaranteeing safety in spatially situated agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohout, R.C.; Hendler, J.A.; Musliner, D.J.

    1996-12-31

    {open_quote}Mission-critical{close_quotes} systems, which include such diverse applications as nuclear power plant controllers, {open_quotes}fly-by-wire{close_quotes} airplanes, medical care and monitoring systems, and autonomous mobile vehicles, are characterized by the fact that system failure is potentially catastrophic. The high cost of failure justifies the expenditure of considerable effort at design-time in order to guarantee the correctness of system behavior. This paper examines the problem of guaranteeing safety in a well studied class of robot motion problems known as the {open_quotes}asteroid avoidance problem.{close_quotes} We establish necessary and sufficient conditions for ensuring safety in the simple version of this problem which occurs most frequently inmore » the literature, as well as sufficient conditions for a more general and realistic case. In doing so, we establish functional relationships between the number, size and speed of obstacles, the robot`s maximum speed and the conditions which must be maintained in order to ensure safety.« less

  8. Nuclear safety

    NASA Technical Reports Server (NTRS)

    Buden, D.

    1991-01-01

    Topics dealing with nuclear safety are addressed which include the following: general safety requirements; safety design requirements; terrestrial safety; SP-100 Flight System key safety requirements; potential mission accidents and hazards; key safety features; ground operations; launch operations; flight operations; disposal; safety concerns; licensing; the nuclear engine for rocket vehicle application (NERVA) design philosophy; the NERVA flight safety program; and the NERVA safety plan.

  9. Applications and safety considerations of Lactobacillus salivarius as a probiotic in animal and human health.

    PubMed

    Chaves, B D; Brashears, M M; Nightingale, K K

    2017-03-03

    The goals of this review are to summarize the current knowledge on the application of Lactobacillus salivarius as a probiotic in animals and humans, and to address safety concerns with its use on live hosts. Overall, several strains of L. salivarius are well established probiotics with multiple applications in animal health, particularly to reduce colonization by gastrointestinal pathogens, and to a lesser extent, as a production and quality aid. In humans, L. salivarius has been used to prevent and treat a variety of chronic diseases, including asthma, cancer, atopic dermatitis and halitosis, and to a much limited extent, to prevent or treat infections. Based on the results from primary research evidence, it seems that L. salivarius does not pose a health risk to animals or humans in the doses currently used for a variety of applications; however, there is a systematic lack of studies assuring the safety of many of the strains intended for clinical use. This review provides researchers in the field with up-to-date information regarding applications and safety of L. salivarius. Furthermore, it helps researchers identify knowledge gaps and potential opportunities for microbiological and clinical research. © 2017 The Society for Applied Microbiology.

  10. Applications of Diagnostic Classification Models: A Literature Review and Critical Commentary

    ERIC Educational Resources Information Center

    Sessoms, John; Henson, Robert A.

    2018-01-01

    Diagnostic classification models (DCMs) classify examinees based on the skills they have mastered given their test performance. This classification enables targeted feedback that can inform remedial instruction. Unfortunately, applications of DCMs have been criticized (e.g., no validity support). Generally, these evaluations have been brief and…

  11. Safety and efficacy of antioxidants-loaded nanoparticles for an anti-aging application.

    PubMed

    Felippi, Cândice C; Oliveira, Dileusa; Ströher, Alessandra; Carvalho, Anderson R; Van Etten, Eliana A M Aquino; Bruschi, Márcia; Raffin, Renata P

    2012-04-01

    The aim of this work was to perform a pilot study on the safety and efficacy of nanoparticle formulation for cosmetic application. The encapsulated actives in the nanoparticles were a blend of coenzyme Q10, retinyl palmitate, tocopheryl acetate, grape seed oil and linseed oil. The nanoparticle suspension was characterized in terms of pH and particle size. For the safety assessment, alternative methods as cytotoxicity and HET CAM were used. The clinical skin compatibility tests were also performed. The efficacy was evaluated in healthy volunteers presenting different degrees of periorbital wrinkles. Skin hydration was performed by corneometry. The nanoparticles presented narrow size around 140 nm and pH close to neutral and were suitable to cutaneous application. The alternative tests demonstrated that the nanoparticles did not present potential to induce skin irritant effects, cytotoxicity or generate oxidative stress. The clinical assays confirmed the in vitro results, demonstrating the safety of the nanoparticles, which were not irritant, sensitizing and comedogenic. Furthermore, the exposure to UVA light did not cause photoxicity. Regarding the efficacy, nanoparticles presented significant reduction in wrinkle degree after 21 days of application compared to the control. The volunteers could differentiate the nanoparticles and the control product by means of subjective analyses. In conclusion, the nanoparticles containing antioxidant actives were safe for topical use and presented anti-aging activity in vivo and are suitable to be used as cosmetic ingredient.

  12. Safety Metrics for Human-Computer Controlled Systems

    NASA Technical Reports Server (NTRS)

    Leveson, Nancy G; Hatanaka, Iwao

    2000-01-01

    The rapid growth of computer technology and innovation has played a significant role in the rise of computer automation of human tasks in modem production systems across all industries. Although the rationale for automation has been to eliminate "human error" or to relieve humans from manual repetitive tasks, various computer-related hazards and accidents have emerged as a direct result of increased system complexity attributed to computer automation. The risk assessment techniques utilized for electromechanical systems are not suitable for today's software-intensive systems or complex human-computer controlled systems.This thesis will propose a new systemic model-based framework for analyzing risk in safety-critical systems where both computers and humans are controlling safety-critical functions. A new systems accident model will be developed based upon modem systems theory and human cognitive processes to better characterize system accidents, the role of human operators, and the influence of software in its direct control of significant system functions Better risk assessments will then be achievable through the application of this new framework to complex human-computer controlled systems.

  13. HYGIENE PRACTICES IN URBAN RESTAURANTS AND CHALLENGES TO IMPLEMENTING FOOD SAFETY AND HAZARD ANALYSIS CRITICAL CONTROL POINTS (HACCP) PROGRAMMES IN THIKA TOWN, KENYA.

    PubMed

    Muinde, R K; Kiinyukia, C; Rombo, G O; Muoki, M A

    2012-12-01

    To determine the microbial load in food, examination of safety measures and possibility of implementing an Hazard Analysis Critical Control Points (HACCP) system. The target population for this study consisted of restaurants owners in Thika. Municipality (n = 30). Simple randomsamples of restaurantswere selected on a systematic sampling method of microbial analysis in cooked, non-cooked, raw food and water sanitation in the selected restaurants. Two hundred and ninety eight restaurants within Thika Municipality were selected. Of these, 30 were sampled for microbiological testing. From the study, 221 (74%) of the restaurants were ready to eat establishments where food was prepared early enough to hold and only 77(26%) of the total restaurants, customers made an order of food they wanted. 118(63%) of the restaurant operators/staff had knowledge on quality control on food safety measures, 24 (8%) of the restaurants applied these knowledge while 256 (86%) of the restaurants staff showed that food contains ingredients that were hazard if poorly handled. 238 (80%) of the resultants used weighing and sorting of food materials, 45 (15%) used preservation methods and the rest used dry foods as critical control points on food safety measures. The study showed that there was need for implementation of Hazard Analysis Critical Control Points (HACCP) system to enhance food safety. Knowledge of HACCP was very low with 89 (30%) of the restaurants applying some of quality measures to the food production process systems. There was contamination with Coliforms, Escherichia coli and Staphylococcus aureus microbial though at very low level. The means of Coliforms, Escherichia coli and Staphylococcus aureas microbial in sampled food were 9.7 x 103CFU/gm, 8.2 x 103 CFU/gm and 5.4 x 103 CFU/gm respectively with Coliforms taking the highest mean.

  14. Towards A Comprehensive Consideration of Epistemic Questions in Software System Safety

    NASA Technical Reports Server (NTRS)

    Holloway, C. M.; Johnson, Chris W.

    2009-01-01

    For any software system upon which lives depend, the most important question one can ask about it is, 'How do we know the system is safe?' Despite the critical importance of this question, no widely accepted, generally applicable answer exists. Instead, debate continues to rage over the question, with theorists and practitioners quarrelling with each other and amongst themselves. This paper suggests a possible way forward towards quelling the quarrels, based on refining the critical safety question into additional questions, which may be more likely to have answers on which a consensus can be reached.

  15. Medication safety in the home care setting: Development and piloting of a Critical Incident Reporting System

    PubMed

    Meyer-Massetti, Carla; Krummenacher, Evelyne; Hedinger-Grogg, Barbara; Luterbacher, Stephan; Hersberger, Kurt E

    2016-09-01

    Background: While drug-related problems are among the most frequent adverse events in health care, little is known about their type and prevalence in home care in the current literature. The use of a Critical Incident Reporting System (CIRS), known as an economic and efficient tool to record medication errors for subsequent analysis, is widely implemented in inpatient care, but less established in ambulatory care. Recommendations on a possible format are scarce. A manual CIRS was developed based on the literature and subsequently piloted and implemented in a Swiss home care organization. Aim: The aim of this work was to implement a critical incident reporting system specifically for medication safety in home care. Results: The final CIRS form was well accepted among staff. Requiring limited resources, it allowed preliminary identification and trending of medication errors in home care. The most frequent error reports addressed medication preparation at the patients’ home, encompassing the following errors: omission (30 %), wrong dose (17.5 %) and wrong time (15 %). The most frequent underlying causes were related to working conditions (37.9 %), lacking attention (68.2 %), time pressure (22.7 %) and interruptions by patients (9.1 %). Conclusions: A manual CIRS allowed efficient data collection and subsequent analysis of medication errors in order to plan future interventions for improvement of medication safety. The development of an electronic CIRS would allow a reduction of the expenditure of time regarding data collection and analysis. In addition, it would favour the development of a national CIRS network among home care institutions.

  16. Mitigating Motion Base Safety Issues: The NASA LaRC CMF Implementation

    NASA Technical Reports Server (NTRS)

    Bryant, Richard B., Jr.; Grupton, Lawrence E.; Martinez, Debbie; Carrelli, David J.

    2005-01-01

    The NASA Langley Research Center (LaRC), Cockpit Motion Facility (CMF) motion base design has taken advantage of inherent hydraulic characteristics to implement safety features using hardware solutions only. Motion system safety has always been a concern and its implementation is addressed differently by each organization. Some approaches rely heavily on software safety features. Software which performs safety functions is subject to more scrutiny making its approval, modification, and development time consuming and expensive. The NASA LaRC's CMF motion system is used for research and, as such, requires that the software be updated or modified frequently. The CMF's customers need the ability to update the simulation software frequently without the associated cost incurred with safety critical software. This paper describes the CMF engineering team's approach to achieving motion base safety by designing and implementing all safety features in hardware, resulting in applications software (including motion cueing and actuator dynamic control) being completely independent of the safety devices. This allows the CMF safety systems to remain intact and unaffected by frequent research system modifications.

  17. A Validation Metrics Framework for Safety-Critical Software-Intensive Systems

    DTIC Science & Technology

    2009-03-01

    so does its definition, tools, and techniques, including means for measuring the validation activity, its outputs, and impact on development...independent of the SDLP. When considering the above SDLPs from the safety engineering team’s perspective, there are also large impacts on the way... impact . Interpretation of any actionable metric data will need to be undertaken in the context of the SDLP. 2. Safety Input The software safety

  18. Safety and feasibility of an exercise prescription approach to rehabilitation across the continuum of care for survivors of critical illness.

    PubMed

    Berney, Sue; Haines, Kimberley; Skinner, Elizabeth H; Denehy, Linda

    2012-12-01

    Survivors of critical illness can experience long-standing functional limitations that negatively affect their health-related quality of life. To date, no model of rehabilitation has demonstrated sustained improvements in physical function for survivors of critical illness beyond hospital discharge. The aims of this study were: (1) to describe a model of rehabilitation for survivors of critical illness, (2) to compare the model to local standard care, and (3) to report the safety and feasibility of the program. This was a cohort study. As part of a larger randomized controlled trial, 74 participants were randomly assigned, 5 days following admission to the intensive care unit (ICU), to a protocolized rehabilitation program that commenced in the ICU and continued on the acute care ward and for a further 8 weeks following hospital discharge as an outpatient program. Exercise training was prescribed based on quantitative outcome measures to achieve a physiological training response. During acute hospitalization, 60% of exercise sessions were able to be delivered. The most frequently occurring barriers to exercise were patient safety and patient refusal due to fatigue. Point prevalence data showed patients were mobilized more often and for longer periods compared with standard care. Outpatient classes were poorly attended, with only 41% of the patients completing more than 70% of outpatient classes. No adverse events occurred. Limitations included patient heterogeneity and delayed commencement of exercise in the ICU due to issues of consent and recruitment. Exercise training that commences in the ICU and continues through to an outpatient program is safe and feasible for survivors of critical illness. Models of care that maximize patient participation across the continuum of care warrant further investigation.

  19. Safety Hazards During Intrahospital Transport: A Prospective Observational Study.

    PubMed

    Bergman, Lina M; Pettersson, Monica E; Chaboyer, Wendy P; Carlström, Eric D; Ringdal, Mona L

    2017-10-01

    To identify, classify, and describe safety hazards during the process of intrahospital transport of critically ill patients. A prospective observational study. Data from participant observations of the intrahospital transport process were collected over a period of 3 months. The study was undertaken at two ICUs in one university hospital. Critically ill patients transported within the hospital by critical care nurses, unlicensed nurses, and physicians. None. Content analysis was performed using deductive and inductive approaches. We detected a total of 365 safety hazards (median, 7; interquartile range, 4-10) during 51 intrahospital transports of critically ill patients, 80% of whom were mechanically ventilated. The majority of detected safety hazards were assessed as increasing the risk of harm, compromising patient safety (n = 204). Using the System Engineering Initiative for Patient Safety, we identified safety hazards related to the work system, as follows: team (n = 61), tasks (n = 83), tools and technologies (n = 124), environment (n = 48), and organization (n = 49). Inductive analysis provided an in-depth description of those safety hazards, contributing factors, and process-related outcomes. Findings suggest that intrahospital transport is a hazardous process for critically ill patients. We have identified several factors that may contribute to transport-related adverse events, which will provide the opportunity for the redesign of systems to enhance patient safety.

  20. Retrieval of Radiology Reports Citing Critical Findings with Disease-Specific Customization

    PubMed Central

    Lacson, Ronilda; Sugarbaker, Nathanael; Prevedello, Luciano M; Ivan, IP; Mar, Wendy; Andriole, Katherine P; Khorasani, Ramin

    2012-01-01

    Background: Communication of critical results from diagnostic procedures between caregivers is a Joint Commission national patient safety goal. Evaluating critical result communication often requires manual analysis of voluminous data, especially when reviewing unstructured textual results of radiologic findings. Information retrieval (IR) tools can facilitate this process by enabling automated retrieval of radiology reports that cite critical imaging findings. However, IR tools that have been developed for one disease or imaging modality often need substantial reconfiguration before they can be utilized for another disease entity. Purpose: This paper: 1) describes the process of customizing two Natural Language Processing (NLP) and Information Retrieval/Extraction applications – an open-source toolkit, A Nearly New Information Extraction system (ANNIE); and an application developed in-house, Information for Searching Content with an Ontology-Utilizing Toolkit (iSCOUT) – to illustrate the varying levels of customization required for different disease entities and; 2) evaluates each application’s performance in identifying and retrieving radiology reports citing critical imaging findings for three distinct diseases, pulmonary nodule, pneumothorax, and pulmonary embolus. Results: Both applications can be utilized for retrieval. iSCOUT and ANNIE had precision values between 0.90-0.98 and recall values between 0.79 and 0.94. ANNIE had consistently higher precision but required more customization. Conclusion: Understanding the customizations involved in utilizing NLP applications for various diseases will enable users to select the most suitable tool for specific tasks. PMID:22934127

  1. Application of visualization and simulation program to improve work zone safety and mobility.

    DOT National Transportation Integrated Search

    2010-01-01

    A previous study sponsored by the Smart Work Zone Deployment Initiative, Feasibility of Visualization and Simulation Applications to Improve Work Zone Safety and Mobility, demonstrated the feasibility of combining readily available, inexpensive...

  2. Application of visualization and simulation program to improve work zone safety and mobility.

    DOT National Transportation Integrated Search

    2010-01-01

    "A previous study sponsored by the Smart Work Zone Deployment Initiative, Feasibility of Visualization and Simulation Applications to Improve Work Zone Safety and Mobility, demonstrated the feasibility of combining readily available, inexpensiv...

  3. Physics of reactor safety. Quarterly report, January--March 1977. [LMFBR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1977-06-01

    This report summarizes work done on reactor safety, Monte Carlo analysis of safety-related critical assembly experiments, and planning of DEMI safety-related critical experiments. Work on reactor core thermal-hydraulics is also included.

  4. Technology and Tool Development to Support Safety and Mission Assurance

    NASA Technical Reports Server (NTRS)

    Denney, Ewen; Pai, Ganesh

    2017-01-01

    The Assurance Case approach is being adopted in a number of safety-mission-critical application domains in the U.S., e.g., medical devices, defense aviation, automotive systems, and, lately, civil aviation. This paradigm refocuses traditional, process-based approaches to assurance on demonstrating explicitly stated assurance goals, emphasizing the use of structured rationale, and concrete product-based evidence as the means for providing justified confidence that systems and software are fit for purpose in safely achieving mission objectives. NASA has also been embracing assurance cases through the concepts of Risk Informed Safety Cases (RISCs), as documented in the NASA System Safety Handbook, and Objective Hierarchies (OHs) as put forth by the Agency's Office of Safety and Mission Assurance (OSMA). This talk will give an overview of the work being performed by the SGT team located at NASA Ames Research Center, in developing technologies and tools to engineer and apply assurance cases in customer projects pertaining to aviation safety. We elaborate how our Assurance Case Automation Toolset (AdvoCATE) has not only extended the state-of-the-art in assurance case research, but also demonstrated its practical utility. We have successfully developed safety assurance cases for a number of Unmanned Aircraft Systems (UAS) operations, which underwent, and passed, scrutiny both by the aviation regulator, i.e., the FAA, as well as the applicable NASA boards for airworthiness and flight safety, flight readiness, and mission readiness. We discuss our efforts in expanding AdvoCATE capabilities to support RISCs and OHs under a project recently funded by OSMA under its Software Assurance Research Program. Finally, we speculate on the applicability of our innovations beyond aviation safety to such endeavors as robotic, and human spaceflight.

  5. Recent trends in SELEX technique and its application to food safety monitoring

    PubMed Central

    Mei, Zhanlong; Yao, Li; Wang, Xin; Zheng, Lei; Liu, Jian; Liu, Guodong; Peng, Chifang; Chen, Wei

    2014-01-01

    The method referred to as “systemic evolution of ligands by exponential enrichment” (SELEX) was introduced in 1990 and ever since has become an important tool for the identification and screening of aptamers. Such nucleic acids can recognize and bind to their corresponding targets (analytes) with high selectivity and affinity, and aptamers therefore have become attractive alternatives to traditional antibodies not the least because they are much more stable. Meanwhile, they have found numerous applications in different fields including food quality and safety monitoring. This review first gives an introduction into the selection process and to the evolution of SELEX, then covers applications of aptamers in the surveillance of food safety (with subsections on absorptiometric, electrochemical, fluorescent and other methods), and then gives conclusions and perspectives. The SELEX method excels by its features of in vitro, high throughput and ease of operation. This review contains 86 references. PMID:25419005

  6. Practical Application of Critical Race Theory: A Social Justice Course Design

    ERIC Educational Resources Information Center

    Pulliam, Rose M.

    2017-01-01

    Social work education aims to prepare students to effectively engage with diverse people and groups. This article presents a practical application of critical race theory (CRT) toward that end. It describes a brief history of curricular approaches to teaching diversity and social justice and examines a few of the challenges with current curricular…

  7. System interface for an integrated intelligent safety system (ISS) for vehicle applications.

    PubMed

    Hannan, Mahammad A; Hussain, Aini; Samad, Salina A

    2010-01-01

    This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications.

  8. System Interface for an Integrated Intelligent Safety System (ISS) for Vehicle Applications

    PubMed Central

    Hannan, Mahammad A.; Hussain, Aini; Samad, Salina A.

    2010-01-01

    This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications. PMID:22205861

  9. Applications of GIS for highway safety : peer exchange summary report, Cambridge, MA, September 14-15, 2011

    DOT National Transportation Integrated Search

    2011-09-30

    On September 14-15, 2011, the FHWA's Office of Planning and its Office of Safety sponsored a 1.5-day peer exchange to promote the use of GIS and mapping for highway safety applications. This report offers overviews of the presentations given at the p...

  10. Application of modified extended method in CREAM for safety inspector in coal mines

    NASA Astrophysics Data System (ADS)

    Wang, Jinhe; Zhang, Xiaohong; Zeng, Jianchao

    2018-01-01

    Safety inspector often performs duties in circumstances contributes to the oc currence of human failures. Therefore, the paper aims at quantifying human failure pro bability (HFP) of safety inspector during the coal mine operation with cognitive reliabi lity and error analysis method (CREAM). Whereas, some shortcomings of this approa ch that lacking considering the applicability of the common performance condition (C PC), and the subjective of evaluating CPC level which weaken the accuracy of the qua ntitative prediction results. A modified extended method in CREAM which is able to a ddress these difficulties with a CPC framework table is proposed, and the proposed me thodology is demonstrated by the virtue of a coal-mine accident example. The results a re expected to be useful in predicting HFP of safety inspector and contribute to the enh ancement of coal mine safety.

  11. Recognizing nurse stakeholder dissonance as a critical determinant of patient safety in new healthcare information technologies.

    PubMed

    Samaras, Elizabeth A; Real, Sara D; Curtis, Amber M; Meunier, Tessa S

    2012-01-01

    Proper identification of all stakeholders and the comprehensive assessment of their evolving and often conflicting Needs, Wants, and Desires (NWDs) is a fundamental principle of human factors science and human-centered systems engineering; it is not yet a consistent element in development and deployment of new health information technologies (HIT). As the single largest group of healthcare professionals, nurses are critical stakeholders for these new technologies. Careful analysis can reveal nurse stakeholder dissonance (NSD) when integrating new technologies into the healthcare environment. Stakeholder dissonance is a term that describes the conflict between the NWDs of different stakeholders which, if left unresolved, can result in dissatisfaction, workarounds, errors, and threats to patient safety. Three case studies drawn from the authors' experience in a variety of acute-care settings where new HITs have been recently deployed are examined to illustrate the concept of NSD. Conflicting NWDs, other stakeholders, and possible root causes of the NSD are analyzed and mapped to threats to patient safety. Lessons learned, practical guidance for anticipating, identifying, and mitigating NSD, future research and implications for HFE and nursing practice are discussed.

  12. 14 CFR 414.19 - Technical criteria for reviewing a safety approval application.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Technical criteria for reviewing a safety approval application. 414.19 Section 414.19 Aeronautics and Space COMMERCIAL SPACE TRANSPORTATION, FEDERAL... regulations. (2) Government-developed or adopted standards. (3) Industry consensus performance-based criteria...

  13. Linking empowering leadership to safety participation in nuclear power plants: a structural equation model.

    PubMed

    Martínez-Córcoles, Mario; Schöbel, Markus; Gracia, Francisco J; Tomás, Inés; Peiró, José M

    2012-07-01

    Safety participation is of paramount importance in guaranteeing the safe running of nuclear power plants. The present study examined the effects of empowering leadership on safety participation. Based on a sample of 495 employees from two Spanish nuclear power plants, structural equation modeling showed that empowering leadership has a significant relationship with safety participation, which is mediated by collaborative team learning. In addition, the results revealed that the relationship between empowering leadership and collaborative learning is partially mediated by the promotion of dialogue and open communication. The implications of these findings for safety research and their practical applications are outlined. An empowering leadership style enhances workers' safety performance, particularly safety participation behaviors. Safety participation is recommended to detect possible rule inconsistencies or misunderstood procedures and make workers aware of critical safety information and issues. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  14. Application of color mixing for safety and quality inspection of agricultural products

    NASA Astrophysics Data System (ADS)

    Ding, Fujian; Chen, Yud-Ren; Chao, Kuanglin

    2005-11-01

    In this paper, color-mixing applications for food safety and quality was studied, including two-color mixing and three-color mixing. It was shown that the chromaticness of the visual signal resulting from two- or three-color mixing is directly related to the band ratio of light intensity at the two or three selected wavebands. An optical visual device using color mixing to implement the band ratio criterion was presented. Inspection through human vision assisted by an optical device that implements the band ratio criterion would offer flexibility and significant cost savings as compared to inspection with a multispectral machine vision system that implements the same criterion. Example applications of this optical color mixing technique were given for the inspection of chicken carcasses with various diseases and for the detection of chilling injury in cucumbers. Simulation results showed that discrimination by chromaticness that has a direct relation with band ratio can work very well with proper selection of the two or three narrow wavebands. This novel color mixing technique for visual inspection can be implemented on visual devices for a variety of applications, ranging from target detection to food safety inspection.

  15. Software Graphics Processing Unit (sGPU) for Deep Space Applications

    NASA Technical Reports Server (NTRS)

    McCabe, Mary; Salazar, George; Steele, Glen

    2015-01-01

    A graphics processing capability will be required for deep space missions and must include a range of applications, from safety-critical vehicle health status to telemedicine for crew health. However, preliminary radiation testing of commercial graphics processing cards suggest they cannot operate in the deep space radiation environment. Investigation into an Software Graphics Processing Unit (sGPU)comprised of commercial-equivalent radiation hardened/tolerant single board computers, field programmable gate arrays, and safety-critical display software shows promising results. Preliminary performance of approximately 30 frames per second (FPS) has been achieved. Use of multi-core processors may provide a significant increase in performance.

  16. 75 FR 44051 - Resolicitation of Applications for the Railroad Safety Technology Program Grant Program (RS-TEC...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... have a public benefit of improved railroad safety and efficiency. The program makes available $50... projects * * * that have a public benefit of improved safety and network efficiency.'' To be eligible for... percent grantee, cost share (cash or in-kind) requirement. Applications that do not clearly indicate at...

  17. Labor unions and safety climate: perceived union safety values and retail employee safety outcomes.

    PubMed

    Sinclair, Robert R; Martin, James E; Sears, Lindsay E

    2010-09-01

    Although trade unions have long been recognized as a critical advocate for employee safety and health, safety climate research has not paid much attention to the role unions play in workplace safety. We proposed a multiple constituency model of workplace safety which focused on three central safety stakeholders: top management, ones' immediate supervisor, and the labor union. Safety climate research focuses on management and supervisors as key stakeholders, but has not considered whether employee perceptions about the priority their union places on safety contributes contribute to safety outcomes. We addressed this gap in the literature by investigating unionized retail employee (N=535) perceptions about the extent to which their top management, immediate supervisors, and union valued safety. Confirmatory factor analyses demonstrated that perceived union safety values could be distinguished from measures of safety training, workplace hazards, top management safety values, and supervisor values. Structural equation analyses indicated that union safety values influenced safety outcomes through its association with higher safety motivation, showing a similar effect as that of supervisor safety values. These findings highlight the need for further attention to union-focused measures related to workplace safety as well as further study of retail employees in general. We discuss the practical implications of our findings and identify several directions for future safety research. 2009 Elsevier Ltd. All rights reserved.

  18. A Software Safety Risk Taxonomy for Use in Retrospective Safety Cases

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    Safety standards contain technical and process-oriented safely requirements. The best time to include these requirements is early in the development lifecycle of the system. When software safety requirements are levied on a legacy system after the fact, a retrospective safety case will need to be constructed for the software in the system. This can be a difficult task because there may be few to no art facts available to show compliance to the software safely requirements. The risks associated with not meeting safely requirements in a legacy safely-critical computer system must be addressed to give confidence for reuse. This paper introduces a proposal for a software safely risk taxonomy for legacy safely-critical computer systems, by specializing the Software Engineering Institute's 'Software Development Risk Taxonomy' with safely elements and attributes.

  19. In Vitro Evaluation of Sunscreen Safety: Effects of the Vehicle and Repeated Applications on Skin Permeation from Topical Formulations

    PubMed Central

    Parenti, Carmela

    2018-01-01

    The evaluation of UV-filter in vitro percutaneous absorption allows the estimation of the systemic exposure dose (SED) and the margin of safety (MoS) of sunscreen products. As both the vehicle and pattern of application may affect sunscreen safety and efficacy, we evaluated in vitro release and skin permeation of two widely used UV-filters, octylmethoxycinnamate (OMC) and butylmethoxydibenzoylmethane (BMBM) from topical formulations with different features (oil in water (O/W) emulsions with different viscosity, water in oil (W/O) emulsion, oils with different lipophilicity). To mimic in-use conditions, we carried out experiments repeating sunscreen application on the skin surface for three consecutive days. BMBM release from all these vehicles was very low, thus leading to poor skin permeation. The vehicle composition significantly affected OMC release and skin permeation, and slight increases of OMC permeation were observed after repeated applications. From skin permeation data, SED and MoS values of BMBM and OMC were calculated for all the investigated formulations after a single application and repeated applications. While MoS values of BMBM were always well beyond the accepted safety limit, the safety of sunscreen formulations containing OMC may depend on the vehicle composition and the application pattern. PMID:29495452

  20. Critical features of an auditable management system for an ISO 9000-compatible occupational health and safety standard.

    PubMed

    Levine, S; Dyjack, D T

    1997-04-01

    An International Organization for Standardization (ISO) 9001: 1994-harmonized occupational health and safety (OHS) management system has been written at the University of Michigan, and reviewed, revised, and accepted under the direction of the American Industrial Hygiene Association (AIHA) Occupational Health and Safety Management Systems (OHSMS) Task Force and the Board of Directors. This system is easily adaptable to the ISO 14001 format and to both OHS and environmental management system applications. As was the case with ISO 9001: 1994, this system is expected to be compatible with current production quality and OHS quality systems and standards, have forward compatibility for new applications, and forward flexibility, with new features added as needed. Since ISO 9001: 1987 and 9001: 1994 have been applied worldwide, the incorporation of harmonized OHS and environmental management system components should be acceptable to business units already performing first-party (self-) auditing, and second-party (contract qualification) auditing. This article explains the basis of this OHS management system, its relationship to ISO 9001 and 14001 standards, the philosophy and methodology of an ISO-harmonized system audit, the relationship of these systems to traditional OHS audit systems, and the authors' vision of the future for application of such systems.

  1. Approaches to culture and diversity: A critical synthesis of occupational therapy literature.

    PubMed

    Beagan, Brenda L

    2015-12-01

    The 2007 position statement on diversity for the Canadian occupational therapy profession argued discussion was needed to determine the implications of approaches to working with cultural differences and other forms of diversity. In 2014, a new position statement on diversity was published, emphasizing the importance of social power relations and power relations between client and therapist, and supporting two particular approaches: cultural safety and cultural humility with critical reflexivity This paper reviews and critically synthesizes the literature concerning culture and diversity published in occupational therapy between 2007 and 2014, tracing the major discourses and mapping the implications of four differing approaches: cultural competence, cultural relevance, cultural safety, and cultural humility. Approaches differ in where they situate the "problem," how they envision change, the end goal, and the application to a range of types of diversity. The latter two are preferred approaches for their attention to power relations and potential to encompass a range of types of social and cultural diversity. © CAOT 2015.

  2. Application of Bayesian informative priors to enhance the transferability of safety performance functions.

    PubMed

    Farid, Ahmed; Abdel-Aty, Mohamed; Lee, Jaeyoung; Eluru, Naveen

    2017-09-01

    Safety performance functions (SPFs) are essential tools for highway agencies to predict crashes, identify hotspots and assess safety countermeasures. In the Highway Safety Manual (HSM), a variety of SPFs are provided for different types of roadway facilities, crash types and severity levels. Agencies, lacking the necessary resources to develop own localized SPFs, may opt to apply the HSM's SPFs for their jurisdictions. Yet, municipalities that want to develop and maintain their regional SPFs might encounter the issue of the small sample bias. Bayesian inference is being conducted to address this issue by combining the current data with prior information to achieve reliable results. It follows that the essence of Bayesian statistics is the application of informative priors, obtained from other SPFs or experts' experiences. In this study, we investigate the applicability of informative priors for Bayesian negative binomial SPFs for rural divided multilane highway segments in Florida and California. An SPF with non-informative priors is developed for each state and its parameters' distributions are assigned to the other state's SPF as informative priors. The performances of SPFs are evaluated by applying each state's SPFs to the other state. The analysis is conducted for both total (KABCO) and severe (KAB) crashes. As per the results, applying one state's SPF with informative priors, which are the other state's SPF independent variable estimates, to the latter state's conditions yields better goodness of fit (GOF) values than applying the former state's SPF with non-informative priors to the conditions of the latter state. This is for both total and severe crash SPFs. Hence, for localities where it is not preferred to develop own localized SPFs and adopt SPFs from elsewhere to cut down on resources, application of informative priors is shown to facilitate the process. Copyright © 2017 National Safety Council and Elsevier Ltd. All rights reserved.

  3. Application of Advanced Fracture Mechanics Technology to Ensure Structural Reliability in Critical Titanium Structures,

    DTIC Science & Technology

    1982-11-22

    RD-Ri42 354 APPLICATION OF ADVANCED FRACTURE MECHANICS TECHNOLOGY i/i TT ENSURE STRUCTURA..(U) 1WESTINGHOUSE RESEARCH FND DEVELOPMENT CENTER...I Iml .4. 47 Igo 12. 4 %B 1. __ ~. ~% ski Z L __ 12 APPLICATION OF ADVANCED FRACTURE MECHANICS -p TECHNOLOGY TO ENSURE STRUCTURAL RELIABILITY IN...Road W Pilttsburgh. Pennsylvania 15235 84 06 18 207 APPLICATION OF ADVANCED FRACTURE MECHANICS TECHNOLOGY TO ENSURE STRUCTURAL RELIABILITY IN CRITICAL

  4. Criticality Safety Evaluation Report CSER-96-019 for Spent Nuclear Fuel (SNF) Processing and Storage Facilities Multi Canister Overpack (MCO)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KESSLER, S.F.

    This criticality evaluation is for Spent N Reactor fuel unloaded from the existing canisters in both KE and KW Basins, and loaded into multiple canister overpack (MCO) containers with specially built baskets containing a maximum of either 54 Mark IV or 48 Mark IA fuel assemblies. The criticality evaluations include loading baskets into the cask-MCO, operation at the Cold Vacuum Drying Facility,a nd storage in the Canister Storage Building. Many conservatisms have been built into this analysis, the primary one being the selection of the K{sub eff} = 0.95 criticality safety limit. This revision incorporates the analyses for the sampling/weldmore » station in the Canister Storage Building and additional analysis of the MCO during the draining at CVDF. Additional discussion of the scrap basket model was added to show why the addition of copper divider plates was not included in the models.« less

  5. Assuring safety without animal testing: Unilever's ongoing research programme to deliver novel ways to assure consumer safety.

    PubMed

    Westmoreland, Carl; Carmichael, Paul; Dent, Matt; Fentem, Julia; MacKay, Cameron; Maxwell, Gavin; Pease, Camilla; Reynolds, Fiona

    2010-01-01

    Assuring consumer safety without the generation of new animal data is currently a considerable challenge. However, through the application of new technologies and the further development of risk-based approaches for safety assessment, we remain confident it is ultimately achievable. For many complex, multi-organ consumer safety endpoints, the development, evaluation and application of new, non-animal approaches is hampered by a lack of biological understanding of the underlying mechanistic processes involved. The enormity of this scientific challenge should not be underestimated. To tackle this challenge a substantial research programme was initiated by Unilever in 2004 to critically evaluate the feasibility of a new conceptual approach based upon the following key components: 1.Developing new, exposure-driven risk assessment approaches. 2.Developing new biological (in vitro) and computer-based (in silico) predictive models. 3.Evaluating the applicability of new technologies for generating data (e.g. "omics", informatics) and for integrating new types of data (e.g. systems approaches) for risk-based safety assessment. Our research efforts are focussed in the priority areas of skin allergy, cancer and general toxicity (including inhaled toxicity). In all of these areas, a long-term investment is essential to increase the scientific understanding of the underlying biology and molecular mechanisms that we believe will ultimately form a sound basis for novel risk assessment approaches. Our research programme in these priority areas consists of in-house research as well as Unilever-sponsored academic research, involvement in EU-funded projects (e.g. Sens-it-iv, Carcinogenomics), participation in cross-industry collaborative research (e.g. Colipa, EPAA) and ongoing involvement with other scientific initiatives on non-animal approaches to risk assessment (e.g. UK NC3Rs, US "Human Toxicology Project" consortium).

  6. 30 CFR 27.4 - Application procedures and requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... applicable MSHA product approval requirements; (iii) Identification of components or features of the product that are critical to the safety of the product; and (iv) All documentation, including drawings and... all components and subassemblies that are submitted for investigation, and shall include wiring and...

  7. 30 CFR 27.4 - Application procedures and requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applicable MSHA product approval requirements; (iii) Identification of components or features of the product that are critical to the safety of the product; and (iv) All documentation, including drawings and... all components and subassemblies that are submitted for investigation, and shall include wiring and...

  8. Emergency responders' critical infrared (ERCI)

    NASA Astrophysics Data System (ADS)

    Konsin, Larry S.

    2004-08-01

    Emergency Responders (Fire, Police, Medical, and Emergency Management) face a high risk of injury or death. Even before September 11, 2001, public and private organizations have been driven to better protect Emergency Responders through education, training and improved technology. Recent research on Emergency Responder safety, health risks, and personal protective requirements, shows infrared (IR) imaging as a critical need. Today"s Emergency Responders are increasingly challenged to do more, facing demands requiring technological assistance and/or solutions. Since the introduction of Fire Service IR imaging in the mid 1990s, applications have increased. Emergency response IR is no longer just seeing through smoke to find victims or the seat of a fire. Many more mission critical needs now exist across the broad spectrum of emergency response. At the same time, Emergency Responder injuries and deaths are increasing. The Office of Domestic Preparedness (ODP) has also recognized IR imaging as critical in protecting our communities -- and in preventing many of the injuries and deaths of Emergency Responders. Currently, only 25% of all fire departments (or less than 7% of individual firefighters) have IR imaging. Availability to Police, EMS and Emergency Management is even lower. Without ERCI, Emergency Responders and our communities are at risk.

  9. Vehicle-to-infrastructure (V2I) safety applications : performance requirements, vol. 1, introduction and common requirements.

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the first of a seven volume report that describes performance requirements for connected vehicle vehicle-to-infrastructure (V2I) Safety Applications developed for the U.S. Department of Transportation (U.S. DOT). The applications add...

  10. The Critical Success Factors Method: Its Application in a Special Library Environment.

    ERIC Educational Resources Information Center

    Borbely, Jack

    1981-01-01

    Discusses the background and theory of the Critical Success Factors (CSF) management method, as well as its application in an information center or other special library environment. CSF is viewed as a management tool that can enhance the viability of the special library within its parent organization. (FM)

  11. Identification of safety-critical events using kinematic vehicle data and the discrete fourier transform.

    PubMed

    Kluger, Robert; Smith, Brian L; Park, Hyungjun; Dailey, Daniel J

    2016-11-01

    Recent technological advances have made it both feasible and practical to identify unsafe driving behaviors using second-by-second trajectory data. Presented in this paper is a unique approach to detecting safety-critical events using vehicles' longitudinal accelerations. A Discrete Fourier Transform is used in combination with K-means clustering to flag patterns in the vehicles' accelerations in time-series that are likely to be crashes or near-crashes. The algorithm was able to detect roughly 78% of crasjavascript:void(0)hes and near-crashes (71 out of 91 validated events in the Naturalistic Driving Study data used), while generating about 1 false positive every 2.7h. In addition to presenting the promising results, an implementation strategy is discussed and further research topics that can improve this method are suggested in the paper. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Priming patient safety: A middle-range theory of safety goal priming via safety culture communication.

    PubMed

    Groves, Patricia S; Bunch, Jacinda L

    2018-05-18

    The aim of this paper is discussion of a new middle-range theory of patient safety goal priming via safety culture communication. Bedside nurses are key to safe care, but there is little theory about how organizations can influence nursing behavior through safety culture to improve patient safety outcomes. We theorize patient safety goal priming via safety culture communication may support organizations in this endeavor. According to this theory, hospital safety culture communication activates a previously held patient safety goal and increases the perceived value of actions nurses can take to achieve that goal. Nurses subsequently prioritize and are motivated to perform tasks and risk assessment related to achieving patient safety. These efforts continue until nurses mitigate or ameliorate identified risks and hazards during the patient care encounter. Critically, this process requires nurses to have a previously held safety goal associated with a repertoire of appropriate actions. This theory suggests undergraduate educators should foster an outcomes focus emphasizing the connections between nursing interventions and safety outcomes, hospitals should strategically structure patient safety primes into communicative activities, and organizations should support professional development including new skills and the latest evidence supporting nursing practice for patient safety. © 2018 John Wiley & Sons Ltd.

  13. A critical assessment of regulatory triggers for products of biotechnology: Product vs. process.

    PubMed

    McHughen, Alan

    2016-10-01

    Regulatory policies governing the safety of genetic engineering (rDNA) and the resulting products (GMOs) have been contentious and divisive, especially in agricultural applications of the technologies. These tensions led to vastly different approaches to safety regulation in different jurisdictions, even though the intent of regulations-to assure public and environmental safety-are common worldwide, and even though the international scientific communities agree on the basic principles of risk assessment and risk management. So great are the political divisions that jurisdictions cannot even agree on the appropriate triggers for regulatory capture, whether product or process. This paper reviews the historical policy and scientific implications of agricultural biotechnology regulatory approaches taken by the European Union, USA and Canada, using their respective statutes and regulations, and then critically assesses the scientific underpinnings of each.

  14. Use and safety of intratumoral application of European mistletoe (Viscum album L) preparations in Oncology.

    PubMed

    Steele, Megan L; Axtner, Jan; Happe, Antje; Kröz, Matthias; Matthes, Harald; Schad, Friedemann

    2015-03-01

    Intratumoral (IT) injection of European mistletoe (Viscum album L) preparations might induce local tumor response through combined cytotoxic and immunomodulatory actions of the preparations. Although promising in vitro and in vivo data, along with clinical case studies suggest the need for validation of this hypothesis in prospective trials, the safety of IT mistletoe injections has yet to be thoroughly assessed. The present study summarizes the practice and safety of off-label IT mistletoe therapy within the Network Oncology, a conjoint clinical registry of German hospitals and outpatients specialized in anthroposophic and integrative medicine. Demographic, diagnosis and treatment data of cancer patients who received IT mistletoe applications between 2007 and 2013 were assessed. Suspected adverse drug reactions (ADRs) were analyzed in terms of type, frequency, severity, seriousness and potential risk factors. A total of 123 cancer patients received 862 IT mistletoe injections (preparations from Abnoba, Helixor and Iscucin). The most commonly applied preparations were Abnoba viscum Fraxini (71 patients) and Helixor Mali (54 patients). Of the total patients, 26 patients (21.1%) experienced 74 ADRs. All ADRs were in response to either Abnoba viscum Fraxini (25.4% of exposed patients) or Helixor Mali (18.5% of exposed patients). ADRs were mostly body temperature or immune related and of mild (83.8%) or moderate (14.9%) intensity. Only one possible ADR was described as severe (hypertension) and no serious ADRs occurred. The frequency of ADRs to IT mistletoe injections was 3 times and 5 times higher than has previously been found for subcutaneous and intravenous applications of mistletoe, respectively. IT injection of mistletoe preparations resulted in a relatively high frequency of ADRs. Nearly all ADRs were mild to moderate however, and no serious ADRs occurred. Furthermore, it is possible that immune-related ADRs such as pyrexia and local inflammatory reactions might

  15. Motor vehicle occupant safety survey

    DOT National Transportation Integrated Search

    1995-09-01

    This report presents findings from the first Motor Vehicle Occupant Safety Survey. The National Highway Traffic Safety Administration (NHTSA) conducted this survey to collect critical information needed by the agency to develop and implement effectiv...

  16. Analyzing Software Errors in Safety-Critical Embedded Systems

    NASA Technical Reports Server (NTRS)

    Lutz, Robyn R.

    1994-01-01

    This paper analyzes the root causes of safty-related software faults identified as potentially hazardous to the system are distributed somewhat differently over the set of possible error causes than non-safety-related software faults.

  17. 10 CFR 76.89 - Criticality accident requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 2 2011-01-01 2011-01-01 false Criticality accident requirements. 76.89 Section 76.89 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.89 Criticality accident requirements. (a) The Corporation must maintain and operate a criticality monitoring and...

  18. 10 CFR 76.89 - Criticality accident requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Criticality accident requirements. 76.89 Section 76.89 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.89 Criticality accident requirements. (a) The Corporation must maintain and operate a criticality monitoring and...

  19. 10 CFR 76.89 - Criticality accident requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 2 2013-01-01 2013-01-01 false Criticality accident requirements. 76.89 Section 76.89 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.89 Criticality accident requirements. (a) The Corporation must maintain and operate a criticality monitoring and...

  20. 10 CFR 76.89 - Criticality accident requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 2 2012-01-01 2012-01-01 false Criticality accident requirements. 76.89 Section 76.89 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.89 Criticality accident requirements. (a) The Corporation must maintain and operate a criticality monitoring and...

  1. 10 CFR 76.89 - Criticality accident requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Criticality accident requirements. 76.89 Section 76.89 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.89 Criticality accident requirements. (a) The Corporation must maintain and operate a criticality monitoring and...

  2. Laser safety programs in general surgery.

    PubMed

    Lanzafame, R J

    1994-06-01

    General surgery represents a speciality where, while any procedure can be performed with lasers, there are no procedures for which the laser is the sine quo non. The general surgeon may perform a variety of procedures with a multitude of laser wavelengths and technologies. Laser safety in general surgery requires a multidisciplinary approach. Effective laser safety requires the oversight of the hospital's "laser usage committee" and "laser safety officer" while providing a workable framework for daily laser use in a variety of clinical scenarios simultaneously. This framework must be user-friendly rather than oppressive. This presentation will describe laser safety at the Rochester General Hospital, a tertiary care, community-based teaching hospital. The safety program incorporates the following components: input to physician credentialing and training, education and in-servicing of nursing and technical personnel, equipment purchase and maintenance, quality assurance, and safety monitoring. The University of Rochester general surgery residency training program mandates laser training during the PGY-2 year. This program stresses the safe use of lasers and provides the basis for graded hands-on experience during the surgical residency. The greatest challenge for laser safety in general surgery centers on the burgeoning field of minimally invasive surgery. Safety assurance must be balanced so as to maintain a safe operating-room environment while ensuring patient safety and the ability to permit the surgery to proceed efficiently. Safety measures for laparoscopic procedures must be sensitive to the needs of the surgical team while not providing confusing signals for the "gallery" observers. This task is critical for the safe operation of lasers in general surgery. Effective laser safety in general surgery requires constant vigilance tempered with sensitivity to the needs of the surgeon and the patient as laser technology and its applications continue to evolve.

  3. Application of a risk management system to improve drinking water safety.

    PubMed

    Jayaratne, Asoka

    2008-12-01

    The use of a comprehensive risk management framework is considered a very effective means of managing water quality risks. There are many risk-based systems available to water utilities such as ISO 9001 and Hazard Analysis and Critical Control Point (HACCP). In 2004, the World Health Organization's (WHO) Guidelines for Drinking Water Quality recommended the use of preventive risk management approaches to manage water quality risks. This paper describes the framework adopted by Yarra Valley Water for the development of its Drinking Water Quality Risk Management Plan incorporating HACCP and ISO 9001 systems and demonstrates benefits of Water Safety Plans such as HACCP. Copyright IWA Publishing 2008.

  4. Application of the Life Safety Code to a Historic Test Stand

    NASA Technical Reports Server (NTRS)

    Askins, Bruce; Lemke, Paul R.; Lewis, William L.; Covell, Carol C.

    2011-01-01

    . An effort was launched to thoroughly evaluate the applicable life safety requirements, examine the context in which they were derived, and determine a means by which the TS4550 modifications could be made within budget and on schedule, while still providing the occupants with appropriate levels of safety.

  5. A Human Reliability Based Usability Evaluation Method for Safety-Critical Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillippe Palanque; Regina Bernhaupt; Ronald Boring

    2006-04-01

    Recent years have seen an increasing use of sophisticated interaction techniques including in the field of safety critical interactive software [8]. The use of such techniques has been required in order to increase the bandwidth between the users and systems and thus to help them deal efficiently with increasingly complex systems. These techniques come from research and innovation done in the field of humancomputer interaction (HCI). A significant effort is currently being undertaken by the HCI community in order to apply and extend current usability evaluation techniques to these new kinds of interaction techniques. However, very little has been donemore » to improve the reliability of software offering these kinds of interaction techniques. Even testing basic graphical user interfaces remains a challenge that has rarely been addressed in the field of software engineering [9]. However, the non reliability of interactive software can jeopardize usability evaluation by showing unexpected or undesired behaviors. The aim of this SIG is to provide a forum for both researchers and practitioners interested in testing interactive software. Our goal is to define a roadmap of activities to cross fertilize usability and reliability testing of these kinds of systems to minimize duplicate efforts in both communities.« less

  6. Safety of High Speed Magnetic Levitation Transportation Systems - Comparison of U.S. and Foreign Safety Requirements for Application to U.S. Maglev Systems

    DOT National Transportation Integrated Search

    1993-09-01

    This report presents the results of a systematic review of the safety requirements selected for the German Transrapid : electromagnetic (EMS) type maglev system to determine their applicability and completeness with respect to the : construction and ...

  7. Quantifying Vermont transportation safety factors.

    DOT National Transportation Integrated Search

    2010-01-01

    VTrans and its partners have selected traffic safety : priority areas in their Strategic Highway Safety Plan. : In this project, researchers focus on three of these : prioritized critical emphasis areas: 1) Keeping vehicles : on the roadway, 2) Young...

  8. Safety leadership and systems thinking: application and evaluation of a Risk Management Framework in the mining industry.

    PubMed

    Donovan, Sarah-Louise; Salmon, Paul M; Lenné, Michael G; Horberry, Tim

    2017-10-01

    Safety leadership is an important factor in supporting safety in high-risk industries. This article contends that applying systems-thinking methods to examine safety leadership can support improved learning from incidents. A case study analysis was undertaken of a large-scale mining landslide incident in which no injuries or fatalities were incurred. A multi-method approach was adopted, in which the Critical Decision Method, Rasmussen's Risk Management Framework and Accimap method were applied to examine the safety leadership decisions and actions which enabled the safe outcome. The approach enabled Rasmussen's predictions regarding safety and performance to be examined in the safety leadership context, with findings demonstrating the distribution of safety leadership across leader and system levels, and the presence of vertical integration as key to supporting the successful safety outcome. In doing so, the findings also demonstrate the usefulness of applying systems-thinking methods to examine and learn from incidents in terms of what 'went right'. The implications, including future research directions, are discussed. Practitioner Summary: This paper presents a case study analysis, in which systems-thinking methods are applied to the examination of safety leadership decisions and actions during a large-scale mining landslide incident. The findings establish safety leadership as a systems phenomenon, and furthermore, demonstrate the usefulness of applying systems-thinking methods to learn from incidents in terms of what 'went right'. Implications, including future research directions, are discussed.

  9. Management commitment to safety as organizational support: relationships with non-safety outcomes in wood manufacturing employees

    Treesearch

    Judd H. Michael; Demetrice D. Evans; Karen J. Jansen; Joel M. Haight

    2005-01-01

    Employee perceptions of management commitment to safety are known to influence important safety-related outcomes. However, little work has been conducted to explore nonsafety-related outcomes resulting from a commitment to safety. Method: Employee-level outcomes critical to the effective functioning of an organization, including attitudes such as job...

  10. A method for identifying EMI critical circuits during development of a large C3

    NASA Astrophysics Data System (ADS)

    Barr, Douglas H.

    The circuit analysis methods and process Boeing Aerospace used on a large, ground-based military command, control, and communications (C3) system are described. This analysis was designed to help identify electromagnetic interference (EMI) critical circuits. The methodology used the MIL-E-6051 equipment criticality categories as the basis for defining critical circuits, relational database technology to help sort through and account for all of the approximately 5000 system signal cables, and Macintosh Plus personal computers to predict critical circuits based on safety margin analysis. The EMI circuit analysis process systematically examined all system circuits to identify which ones were likely to be EMI critical. The process used two separate, sequential safety margin analyses to identify critical circuits (conservative safety margin analysis, and detailed safety margin analysis). These analyses used field-to-wire and wire-to-wire coupling models using both worst-case and detailed circuit parameters (physical and electrical) to predict circuit safety margins. This process identified the predicted critical circuits that could then be verified by test.

  11. Fault Detection and Safety in Closed-Loop Artificial Pancreas Systems

    PubMed Central

    2014-01-01

    Continuous subcutaneous insulin infusion pumps and continuous glucose monitors enable individuals with type 1 diabetes to achieve tighter blood glucose control and are critical components in a closed-loop artificial pancreas. Insulin infusion sets can fail and continuous glucose monitor sensor signals can suffer from a variety of anomalies, including signal dropout and pressure-induced sensor attenuations. In addition to hardware-based failures, software and human-induced errors can cause safety-related problems. Techniques for fault detection, safety analyses, and remote monitoring techniques that have been applied in other industries and applications, such as chemical process plants and commercial aircraft, are discussed and placed in the context of a closed-loop artificial pancreas. PMID:25049365

  12. 76 FR 71081 - Public Aircraft Oversight Safety Forum

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... NATIONAL TRANSPORTATION SAFETY BOARD Public Aircraft Oversight Safety Forum The National Transportation Safety Board (NTSB) will convene a Public Aircraft Oversight Safety Forum which will begin at 9 a... ``Public Aircraft Oversight Forum: Ensuring Safety for Critical Missions'', are to (1) raise awareness of...

  13. Development of a multimedia tutorial to educate how to assess the critical view of safety in laparoscopic cholecystectomy using expert review and crowd-sourcing.

    PubMed

    Deal, Shanley B; Stefanidis, Dimitrios; Brunt, L Michael; Alseidi, Adnan

    2017-05-01

    We sought to determine the feasibility of developing a multimedia educational tutorial to teach learners to assess the critical view of safety using input from expert surgeons, non-surgeons and crowd-sourcing. We intended to develop a tutorial that would teach learners how to identify the basic anatomy and physiology of the gallbladder, identify the components of the critical view of safety criteria, and understand its significance for performing a safe gallbladder removal. Using rounds of assessment with experts, laypersons and crowd-workers we developed an educational video with improving comprehension after each round of revision. We demonstrate that the development of a multimedia educational tool to educate learners of various backgrounds is feasible using an iterative review process that incorporates the input of experts and crowd sourcing. When planning the development of an educational tutorial, a step-wise approach as described herein should be considered. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. 14 CFR 35.16 - Propeller critical parts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller critical parts. 35.16 Section 35... AIRWORTHINESS STANDARDS: PROPELLERS Design and Construction § 35.16 Propeller critical parts. The integrity of each propeller critical part identified by the safety analysis required by § 35.15 must be established...

  15. In vitro dosimetry modeling will be a critical step toward efficient assessment of engineered nanomaterials for environmental health and safety

    EPA Science Inventory

    Presentation Description: The development and application of engineered nanomaterials (ENM) into commercial and consumer products is far outpacing the ability of traditional approaches to evaluate the potential implications for environmental health and safety. This problem recen...

  16. How often do surgeons obtain the critical view of safety during laparoscopic cholecystectomy?

    PubMed

    Stefanidis, Dimitrios; Chintalapudi, Nikita; Anderson-Montoya, Brittany; Oommen, Bindhu; Tobben, Daniel; Pimentel, Manuel

    2017-01-01

    The reported incidence (0.16-1.5 %) of bile duct injury (BDI) during laparoscopic cholecystectomy (LC) is higher than during open cholecystectomy and has not decreased over time despite increasing experience with the procedure. The "critical view of safety" (CVS) technique may help to prevent BDI when certain criteria are met prior to division of any structures. This study aimed to evaluate the adherence of practicing surgeons to the CVS criteria during LC and the impact of a training intervention on CVS identification. LC procedures of general surgeons were video-recorded. De-identified recordings were reviewed by a blinded observer and rated on a 6-point scale using the previously published CVS criteria. A coaching program was conducted, and participating surgeons were re-assessed in the same manner. The observer assessed ten LC videos, each involving a different surgeon. The CVS was adequately achieved by two surgeons (20 %). The remaining eight surgeons (80 %) did not obtain adequate CVS prior to division of any structures, despite two surgeons dictating that they did; the mean score of this group was 1.75. After training, five participating surgeons (50 %) scored > 4, and the mean increased from 1.75 (baseline) to 3.75 (p < 0.05). The CVS criteria were not routinely used by the majority of participating surgeons. Further, one-fourth of those who claimed to obtain the CVS did so inadequately. All surgeons who participated in training showed improvement during their post-assessment. Our findings suggest that education of practicing surgeons in the application of the CVS during LC can result in increased implementation and quality of the CVS. Pending studies with larger samples, our findings may partly explain the sustained BDI incidence despite increased experience with LC. Our study also supports the value of direct observation of surgical practices and subsequent training for quality improvement.

  17. Phenomenological Studies on Sodium for CSP Applications: A Safety Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Armijo, Kenneth Miguel; Andraka, Charles E.

    Sodium as a heat transfer fluid (HTF) can achieve temperatures above 700°C to improve power cycle performance for reducing large infrastructure costs of high-temperature systems. Current concentrating solar power (CSP) sensible HTF’s (e.g. air, salts) have poor thermal conductivity, and thus low heat transfer capabilities, requiring a large receiver. The high thermal conductivity of sodium has demonstrated high heat transfer rates on dish and towers systems, which allow a reduction in receiver area by a factor of two to four, reducing re-radiation and convection losses and cost by a similar factor. Sodium produces saturated vapor at pressures suitable for transportmore » starting at 600°C and reaches one atmosphere at 870°C, providing a wide range of suitable latent operating conditions that match proposed high temperature, isothermal input power cycles. This advantage could increase the receiver and system efficiency while lowering the cost of CSP tower systems. Although there are a number of desirable thermal performance advantages associated with sodium, its propensity to rapidly oxidize presents safety challenges. This investigation presents a literature review that captures historical operations/handling lessons for advanced sodium systems, and the current state-of-knowledge related to sodium combustion behavior. Technical and operational solutions addressing sodium safety and applications in CSP will be discussed, including unique safety hazards and advantages using latent sodium. Operation and maintenance experience from the nuclear industry with sensible and latent systems will also be discussed in the context of safety challenges and risk mitigation solutions.« less

  18. Phenomenological studies on sodium for CSP applications: A safety review

    NASA Astrophysics Data System (ADS)

    Armijo, Kenneth M.; Andraka, Charles E.

    2016-05-01

    Sodium Heat transfer fluids (HTF) such as sodium, can achieve temperatures above 700°C to obtain power cycle performance improvements for reducing large infrastructure costs of high-temperature systems. Current concentrating solar power (CSP) sensible HTF's (e.g. air, salts) have poor thermal conductivity, and thus low heat transfer capabilities, requiring a large receiver. The high thermal conductivity of sodium has demonstrated high heat transfer rates on dish and towers systems, which allow a reduction in receiver area by a factor of two to four, reducing re-radiation and convection losses and cost by a similar factor. Sodium produces saturated vapor at pressures suitable for transport starting at 600°C and reaches one atmosphere at 870°C, providing a wide range of suitable operating conditions that match proposed high temperature, isothermal power cycles. This advantage could increase the efficiency while lowering the cost of CSP tower systems. Although there are a number of desirable thermal performance advantages associated with sensible sodium, its propensity to rapidly oxidize presents safety challenges. This investigation presents a literature review that captures historical operations/handling lessons for advanced sodium receiver designs, and the current state-of-knowledge related to sodium combustion behavior. Technical and operational solutions addressing sodium safety and applications in CSP will be discussed, including unique safety hazards and advantages using latent sodium. Lessons obtained from the nuclear industry with sensible and latent systems will also be discussed in the context of safety challenges and risk mitigation solutions.

  19. Collegiate Aviation Research and Education Solutions to Critical Safety Issues

    NASA Technical Reports Server (NTRS)

    Bowen, Brent (Editor)

    2002-01-01

    This Conference Proceedings is a collection of 6 abstracts and 3 papers presented April 19-20, 2001 in Denver, CO. The conference focus was "Best Practices and Benchmarking in Collegiate and Industry Programs". Topics covered include: satellite-based aviation navigation; weather safety training; human-behavior and aircraft maintenance issues; disaster preparedness; the collegiate aviation emergency response checklist; aviation safety research; and regulatory status of maintenance resource management.

  20. Safety cases for medical devices and health information technology: involving health-care organisations in the assurance of safety.

    PubMed

    Sujan, Mark A; Koornneef, Floor; Chozos, Nick; Pozzi, Simone; Kelly, Tim

    2013-09-01

    In the United Kingdom, there are more than 9000 reports of adverse events involving medical devices annually. The regulatory processes in Europe and in the United States have been challenged as to their ability to protect patients effectively from unreasonable risk and harm. Two of the major shortcomings of current practice include the lack of transparency in the safety certification process and the lack of involvement of service providers. We reviewed recent international standardisation activities in this area, and we reviewed regulatory practices in other safety-critical industries. The review showed that the use of safety cases is an accepted practice in UK safety-critical industries, but at present, there is little awareness of this concept in health care. Safety cases have the potential to provide greater transparency and confidence in safety certification and to act as a communication tool between manufacturers, service providers, regulators and patients.

  1. Experience With Laser Safety In The USA--A Review

    NASA Astrophysics Data System (ADS)

    Sliney, David H.

    1986-10-01

    Following several research programs in the 1960's aimed at studying the adverse biological effects of lasers and other optical radiation sources, laser occupational exposure limits were set and general safety standards were developed. Today, the experience from laser accidents and the development of new lasers and new applications have altered the format of the exposure limits and the safety procedures. It is critically important to distinguish between different biological injury mechanisms. The biological effects of ultraviolet radiation upon the skin and eye are additive over a period of at least one workday, and require different safety procedures. The scattered UV irradiance from excimer lasers may be quite hazardous, depending upon wavelength and action spectra. Since laser technology is young, the exposure of an individual in natural sunlight must be studied to evaluate the potential for chronic effects. The safety measures necessary in the use of lasers depend upon a hazard evaluation. The appropriate control measures and alternate means of enclosure, baffling, and operational control measures are presented. Present laser safety standards are explained briefly. Eye protective techniques and eyewear are considered for a variety of sources. The optical properties of enclosure materials are also discussed.

  2. 14 CFR 415.33 - Safety organization.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Safety organization. 415.33 Section 415.33....33 Safety organization. (a) An applicant shall maintain a safety organization and document it by... communication, both within the applicant's organization and between the applicant and any federal launch range...

  3. Overview of Experiments for Physics of Fast Reactors from the International Handbooks of Evaluated Criticality Safety Benchmark Experiments and Evaluated Reactor Physics Benchmark Experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bess, J. D.; Briggs, J. B.; Gulliford, J.

    mentioning is the critical experiments with fast reactor fuel rods in water, interesting in terms of justification of nuclear safety during transportation and storage of fresh and spent fuel. These reports provide a detailed review of the experiment, designate the area of their application and include results of calculations on modern systems of constants in comparison with the estimated experimental data.« less

  4. RFID Application Strategy in Agri-Food Supply Chain Based on Safety and Benefit Analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Min; Li, Peichong

    Agri-food supply chain management (SCM), a management method to optimize internal costs and productivities, has evolved as an application of e-business technologies. These days, RFID has been widely used in many fields. In this paper, we analyze the characteristics of agri-food supply chain. Then the disadvantages of RFID are discussed. After that, we study the application strategies of RFID based on benefit and safety degree.

  5. Microbial food safety - modeling and applications

    USDA-ARS?s Scientific Manuscript database

    Microbial food safety is a key issue for the food processing industry, and enhancing food safety is everyone’s responsibility from food producers to consumers. Financial losses to the economy due to foodborne illness are in the billions of dollars, annually. Foodborne illness can be caused by patho...

  6. Application of Smart Solid State Sensor Technology in Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Xu, Jennifer C.; Dungan, L.K.; Makel, D.; Ward, B.; Androjna, D.

    2008-01-01

    Aerospace applications require a range of chemical sensing technologies to monitor conditions in both space vehicles and aircraft operations. One example is the monitoring of oxygen. For example, monitoring of ambient oxygen (O2) levels is critical to ensuring the health, safety, and performance of humans living and working in space. Oxygen sensors can also be incorporated in detection systems to determine if hazardous leaks are occurring in space propulsion systems and storage facilities. In aeronautic applications, O2 detection has been investigated for fuel tank monitoring. However, as noted elsewhere, O2 is not the only species of interest in aerospace applications with a wide range of species of interest being relevant to understand an environmental or vehicle condition. These include combustion products such as CO, HF, HCN, and HCl, which are related to both the presence of a fire and monitoring of post-fire clean-up operations. This paper discusses the development of an electrochemical cell platform based on a polymer electrolyte, NAFION, and a three-electrode configuration. The approach has been to mature this basic platform for a range of applications and to test this system, combined with "Lick and Stick" electronics, for its viability to monitor an environment related to astronaut crew health and safety applications with an understanding that a broad range of applications can be addressed with a core technology.

  7. Health and Safety Advisory Committee (HASAC) of the International Embryo Transfer Society (IETS) has managed critical challenges for two decades.

    PubMed

    Thibier, M; Stringfellow, D A

    2003-02-01

    The International Embryo Transfer Society (IETS) was founded in 1974. Early members used the society as a forum for the exchange of scientific and technical information relevant to a newly emerging embryo transfer industry. The impact that embryo transfer could have on the international trade of livestock genetics was clear by 1982, so the IETS commissioned the Import/Export Committee. The initial challenge for this Committee was to deal with concerns about disease transmission via embryo transfer. Many of the early concerns have been dispelled, but at the time they threatened the continued development of a fledgling industry. Over the past two decades, many new critical challenges have been met and managed by this Committee, which was recently renamed the Health and Safety Advisory Committee (HASAC). Assessing risks of animal disease transmission via reproductive technologies and establishing protocols for managing these risks are still major issues for HASAC. However, additional concerns have developed as views of the society changed and as novel applications of biotechnology in farm animals were identified. This paper is intended to chronicle some of the major changes and challenges that were managed by members of the HASAC and its Subcommittees from the early years of embryo transfer to the current millennium with technological advances in molecular biology.

  8. The Critical Mass Laboratory at Rocky Flats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rothe, Robert E

    2003-10-15

    The Critical Mass Laboratory (CML) at Rocky Flats northwest of Denver, Colorado, was built in 1964 and commissioned to conduct nuclear experiments on January 28, 1965. It was built to attain more accurate and precise experimental data to ensure nuclear criticality safety at the plant than were previously possible. Prior to its construction, safety data were obtained from long extrapolations of subcritical data (called in situ experiments), calculated parameters from reactor engineering 'models', and a few other imprecise methods. About 1700 critical and critical-approach experiments involving several chemical forms of enriched uranium and plutonium were performed between then and 1988.more » These experiments included single units and arrays of fissile materials, reflected and 'bare' systems, and configurations with various degrees of moderation, as well as some containing strong neutron absorbers. In 1989, a raid by the Federal Bureau of Investigation (FBI) caused the plant as a whole to focus on 'resumption' instead of further criticality safety experiments. Though either not recognized or not admitted for a few years, that FBI raid did sound the death knell for the CML. The plant's optimistic goal of resumption evolved to one of deactivation, decommissioning, and plantwide demolition during the 1990s. The once-proud CML facility was finally demolished in April of 2002.« less

  9. 78 FR 11737 - Improving Critical Infrastructure Cybersecurity

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-19

    ... of America, it is hereby ordered as follows: Section 1. Policy. Repeated cyber intrusions into critical infrastructure demonstrate the need for improved cybersecurity. The cyber threat to critical... cyber environment that encourages efficiency, innovation, and economic prosperity while promoting safety...

  10. The application of the psychological contract to workplace safety.

    PubMed

    Walker, Arlene; Hutton, Dorothy M

    2006-01-01

    Psychological contracts of safety are conceptualized as the beliefs of individuals about reciprocal safety obligations inferred from implicit or explicit promises. Although the literature on psychological contracts is growing, the existence of psychological contracts in relation to safety has not been established. The research sought to identify psychological contracts in the conversations of employees about safety, by demonstrating reciprocity in relation to employer and employee safety obligations. The identified safety obligations were used to develop a measure of psychological contracts of safety. The participants were 131 employees attending safety training sessions in retail and manufacturing organizations. Non-participant observation was used to collect the data during safety training sessions. Content analysis was used to analyze the data. Categories for coding were established through identification of language markers that demonstrated contingencies or other implied obligations. Direct evidence of reciprocity between employer safety obligations and employee safety obligations was found in statements from the participants demonstrating psychological contracts. A comprehensive list of perceived employer and employee safety obligations was compiled and developed into a measure of psychological contracts of safety. A small sample of 33 safety personnel was used to validate the safety obligations. CONCLUSIONS AND IMPACT ON INDUSTRY: Implications of these findings for safety and psychological contract research are discussed.

  11. Adverse Outcome Pathways can drive non-animal approaches for safety assessment

    PubMed Central

    Burden, Natalie; Sewell, Fiona; Andersen, Melvin E; Boobis, Alan; Chipman, J Kevin; Cronin, Mark T D; Hutchinson, Thomas H; Kimber, Ian; Whelan, Maurice

    2015-01-01

    Adverse Outcome Pathways (AOPs) provide an opportunity to develop new and more accurate safety assessment processes for drugs and other chemicals, and may ultimately play an important role in regulatory decision making. Not only can the development and application of AOPs pave the way for the development of improved evidence-based approaches for hazard and risk assessment, there is also the promise of a significant impact on animal welfare, with a reduced reliance on animal-based methods. The establishment of a useable and coherent knowledge framework under which AOPs will be developed and applied has been a first critical step towards realizing this opportunity. This article explores how the development of AOPs under this framework, and their application in practice, could benefit the science and practice of safety assessment, while in parallel stimulating a move away from traditional methods towards an increased acceptance of non-animal approaches. We discuss here the key areas where current, and future initiatives should be focused to enable the translation of AOPs into routine chemical safety assessment, and lasting 3Rs benefits. © 2015 The Authors. Journal of Applied Toxicology published by John Wiley & Sons Ltd. This article explores how the development and application of Adverse Outcome Pathways (AOPs) could benefit the science and practice of chemical safety assessment, with a particular focus on how their use in practice could reduce reliance on traditional animal toxicity tests. This includes discussion of the key areas where current and future initiatives should be focused to enable the translation of AOPs into routine chemical safety assessment, and lasting 3Rs benefits. PMID:25943792

  12. A focused approach to safety guidebook.

    DOT National Transportation Integrated Search

    2011-08-23

    "The Federal Highway Administration (FHWA) has developed the Focused Approach to Safety in order to better address the most critical safety challenges by devoting additional attention to high priority States. The purpose of the Focused Approach is to...

  13. The Inside Information about Safety Surfacing.

    ERIC Educational Resources Information Center

    Thompson, Donna; Hudson, Susan

    2003-01-01

    Tested the impact attenuation characteristics of safety surfaces used in indoor child care play settings. Found that the most common surfaces used were indoor/outdoor carpet, various types of mats, and safety floor tiles. Nearly 60 percent of tested materials had a critical fall height of 1 foot or less. Concluded that carpet, safety tile, and…

  14. Laser safety research and modeling for high-energy laser systems

    NASA Astrophysics Data System (ADS)

    Smith, Peter A.; Montes de Oca, Cecilia I.; Kennedy, Paul K.; Keppler, Kenneth S.

    2002-06-01

    The Department of Defense has an increasing number of high-energy laser weapons programs with the potential to mature in the not too distant future. However, as laser systems with increasingly higher energies are developed, the difficulty of the laser safety problem increases proportionally, and presents unique safety challenges. The hazard distance for the direct beam can be in the order of thousands of miles, and radiation reflected from the target may also be hazardous over long distances. This paper details the Air Force Research Laboratory/Optical Radiation Branch (AFRL/HEDO) High-Energy Laser (HEL) safety program, which has been developed to support DOD HEL programs by providing critical capability and knowledge with respect to laser safety. The overall aim of the program is to develop and demonstrate technologies that permit safe testing, deployment and use of high-energy laser weapons. The program spans the range of applicable technologies, including evaluation of the biological effects of high-energy laser systems, development and validation of laser hazard assessment tools, and development of appropriate eye protection for those at risk.

  15. Safety of intravenous lacosamide in critically ill children.

    PubMed

    Welsh, Sarah S; Lin, Nan; Topjian, Alexis A; Abend, Nicholas S

    2017-11-01

    Acute seizures are common in critically ill children. These patients would benefit from intravenous anti-seizure medications with few adverse effects. We reviewed the usage and effects of intravenous lacosamide in critically ill children with seizures or status epilepticus. This retrospective series included consecutive patients who received at least one dose of intravenous lacosamide from April 2011 to February 2016 in the pediatric intensive care unit of a quaternary care children's hospital, including patients with new lacosamide initiation and continuation of outpatient oral lacosamide. Dosing and prescribing practices were reviewed. Adverse effects were defined by predefined criteria, and most were evaluated during the full admission. We identified 51 intensive care unit admissions (47 unique patients) with intravenous lacosamide administration. Lacosamide was utilized as a third or fourth-line anti-seizure medication for acute seizures or status epilepticus in the lacosamide-naïve cohort. One patient experienced bradycardia and one patient experienced a rash that were considered potentially related to lacosamide. No other adverse effects were identified, including no evidence of PR interval prolongation. Lacosamide was well tolerated in critically ill children. Further study is warranted to evaluate the effectiveness of earlier lacosamide use for pediatric status epilepticus and acute seizures. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  16. Establishment of microbiological safety criteria for foods in international trade. International Commission on Microbiological Specifications for Foods.

    PubMed

    1997-01-01

    Microbiological safety is achieved by applying good hygienic practices throughout the food chain, "from farm to fork". Governmental food control is traditionally based on inspection of the facilities where foods are handled, and on testing food samples. Testing is usually applied to imported foods, when no information concerning the safety of a consignment is available. The microbiological safety is judged by means of microbiological criteria. Such criteria should, in the context of the WTO/SPS measures, be scientifically justified, and established according to the principles described by the Codex Alimentarius. However, microbiological testing is not a very reliable tool for consumer protection; the emphasis is currently shifting to the application of food safety management tools such as the Hazard Analysis Critical Control Point system (HACCP).

  17. Failure Modes Effects and Criticality Analysis, an Underutilized Safety, Reliability, Project Management and Systems Engineering Tool

    NASA Astrophysics Data System (ADS)

    Mullin, Daniel Richard

    2013-09-01

    The majority of space programs whether manned or unmanned for science or exploration require that a Failure Modes Effects and Criticality Analysis (FMECA) be performed as part of their safety and reliability activities. This comes as no surprise given that FMECAs have been an integral part of the reliability engineer's toolkit since the 1950s. The reasons for performing a FMECA are well known including fleshing out system single point failures, system hazards and critical components and functions. However, in the author's ten years' experience as a space systems safety and reliability engineer, findings demonstrate that the FMECA is often performed as an afterthought, simply to meet contract deliverable requirements and is often started long after the system requirements allocation and preliminary design have been completed. There are also important qualitative and quantitative components often missing which can provide useful data to all of project stakeholders. These include; probability of occurrence, probability of detection, time to effect and time to detect and, finally, the Risk Priority Number. This is unfortunate as the FMECA is a powerful system design tool that when used effectively, can help optimize system function while minimizing the risk of failure. When performed as early as possible in conjunction with writing the top level system requirements, the FMECA can provide instant feedback on the viability of the requirements while providing a valuable sanity check early in the design process. It can indicate which areas of the system will require redundancy and which areas are inherently the most risky from the onset. Based on historical and practical examples, it is this author's contention that FMECAs are an immense source of important information for all involved stakeholders in a given project and can provide several benefits including, efficient project management with respect to cost and schedule, system engineering and requirements management

  18. Operating safely in surgery and critical care with perioperative automation.

    PubMed

    Grover, Christopher; Barney, Kate

    2004-01-01

    A study by the Institute of Medicine (IOM) found that as many as 98,000 Americans die each year from preventable medical errors. These findings, combined with a growing spate of negative publicity, have brought patient safety to its rightful place at the healthcare forefront. Nowhere are patient safety issues more critical than in the anesthesia, surgery and critical care environments. These high-acuity settings--with their fast pace, complex and rapidly changing care regimens and mountains of diverse clinical data-arguably pose the greatest patient safety risk in the hospital.

  19. Physical Education Pre-Service Teachers' Understanding, Application, and Development of Critical Thinking

    ERIC Educational Resources Information Center

    Liu, Jiling; McBride, Ron E.; Xiang, Ping; Scarmardo-Rhodes, Melissa

    2018-01-01

    To better prepare physical education (PE) teachers, this study explored a group of pre-service teachers' understanding, application, and development of critical thinking (CT) in a capstone methods course. Participants were 12 pre-service teachers from a PE teacher education (PETE) program at a large university in the southwestern United States.…

  20. Modeling, Evaluation and Detection of Jamming Attacks in Time-Critical Wireless Applications

    DTIC Science & Technology

    2014-08-01

    computing, modeling and analysis of wireless networks , network topol- ogy, and architecture design. Dr. Wang has been a Member of the Association for...important, yet open research question is how to model and detect jamming attacks in such wireless networks , where communication traffic is more time...against time-critical wireless networks with applications to the smart grid. In contrast to communication networks where packets-oriented metrics

  1. Hazard Analysis and Critical Control Points among Chinese Food Business Operators.

    PubMed

    Saccares, Stefano; Amadei, Paolo; Masotti, Gianfranco; Condoleo, Roberto; Guidi, Alessandra

    2014-08-28

    The purpose of the present paper is to highlight some critical situations emerged during the implementation of long-term projects locally managed by Prevention Services, to control some manufacturing companies in Rome and Prato, Central Italy. In particular, some critical issues on the application of self-control in marketing and catering held by Chinese operators are underlined. The study showed serious flaws in preparing and controlling of manuals for good hygiene practice, participating of the consultants among food business operators (FBOs) to the control of the procedures. Only after regular actions by the Prevention Services, there have been satisfying results. This confirms the need to have qualified and expert partners able to promptly act among FBOs and to give adequate support to authorities in charge in order to guarantee food safety.

  2. 10 CFR 52.79 - Contents of applications; technical information in final safety analysis report.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... assurance program will be implemented; (26) The applicant's organizational structure, allocations or... presents a safety analysis of the structures, systems, and components of the facility as a whole. The final... contain an analysis and evaluation of the major structures, systems, and components of the facility that...

  3. Failure modes and effects criticality analysis and accelerated life testing of LEDs for medical applications

    NASA Astrophysics Data System (ADS)

    Sawant, M.; Christou, A.

    2012-12-01

    While use of LEDs in Fiber Optics and lighting applications is common, their use in medical diagnostic applications is not very extensive. Since the precise value of light intensity will be used to interpret patient results, understanding failure modes [1-4] is very important. We used the Failure Modes and Effects Criticality Analysis (FMECA) tool to identify the critical failure modes of the LEDs. FMECA involves identification of various failure modes, their effects on the system (LED optical output in this context), their frequency of occurrence, severity and the criticality of the failure modes. The competing failure modes/mechanisms were degradation of: active layer (where electron-hole recombination occurs to emit light), electrodes (provides electrical contact to the semiconductor chip), Indium Tin Oxide (ITO) surface layer (used to improve current spreading and light extraction), plastic encapsulation (protective polymer layer) and packaging failures (bond wires, heat sink separation). A FMECA table is constructed and the criticality is calculated by estimating the failure effect probability (β), failure mode ratio (α), failure rate (λ) and the operating time. Once the critical failure modes were identified, the next steps were generation of prior time to failure distribution and comparing with our accelerated life test data. To generate the prior distributions, data and results from previous investigations were utilized [5-33] where reliability test results of similar LEDs were reported. From the graphs or tabular data, we extracted the time required for the optical power output to reach 80% of its initial value. This is our failure criterion for the medical diagnostic application. Analysis of published data for different LED materials (AlGaInP, GaN, AlGaAs), the Semiconductor Structures (DH, MQW) and the mode of testing (DC, Pulsed) was carried out. The data was categorized according to the materials system and LED structure such as AlGaInP-DH-DC, Al

  4. Public service communications satellite. [health, education, safety and information transfer applications

    NASA Technical Reports Server (NTRS)

    Wolff, E. A.

    1978-01-01

    Health, education, public safety, and information transfer applications of public service communications satellites are discussed with particular attention to the use of communications satellites to improve rural health delivery. Health-care communications requirements are summarized. The communications system concept involves small inexpensive stationary, portable, and moving ground terminals which will provide communications between any two points in the U.S. with both fixed and moving terminals on a continuous 24-hour basis. User requirements, wavebands, and privacy techniques are surveyed.

  5. Duke Surgery Patient Safety: an open-source application for anonymous reporting of adverse and near-miss surgical events

    PubMed Central

    Pietrobon, Ricardo; Lima, Raquel; Shah, Anand; Jacobs, Danny O; Harker, Matthew; McCready, Mariana; Martins, Henrique; Richardson, William

    2007-01-01

    Background Studies have shown that 4% of hospitalized patients suffer from an adverse event caused by the medical treatment administered. Some institutions have created systems to encourage medical workers to report these adverse events. However, these systems often prove to be inadequate and/or ineffective for reviewing the data collected and improving the outcomes in patient safety. Objective To describe the Web-application Duke Surgery Patient Safety, designed for the anonymous reporting of adverse and near-miss events as well as scheduled reporting to surgeons and hospital administration. Software architecture DSPS was developed primarily using Java language running on a Tomcat server and with MySQL database as its backend. Results Formal and field usability tests were used to aid in development of DSPS. Extensive experience with DSPS at our institution indicate that DSPS is easy to learn and use, has good speed, provides needed functionality, and is well received by both adverse-event reporters and administrators. Discussion This is the first description of an open-source application for reporting patient safety, which allows the distribution of the application to other institutions in addition for its ability to adapt to the needs of different departments. DSPS provides a mechanism for anonymous reporting of adverse events and helps to administer Patient Safety initiatives. Conclusion The modifiable framework of DSPS allows adherence to evolving national data standards. The open-source design of DSPS permits surgical departments with existing reporting mechanisms to integrate them with DSPS. The DSPS application is distributed under the GNU General Public License. PMID:17472749

  6. Duke Surgery Patient Safety: an open-source application for anonymous reporting of adverse and near-miss surgical events.

    PubMed

    Pietrobon, Ricardo; Lima, Raquel; Shah, Anand; Jacobs, Danny O; Harker, Matthew; McCready, Mariana; Martins, Henrique; Richardson, William

    2007-05-01

    Studies have shown that 4% of hospitalized patients suffer from an adverse event caused by the medical treatment administered. Some institutions have created systems to encourage medical workers to report these adverse events. However, these systems often prove to be inadequate and/or ineffective for reviewing the data collected and improving the outcomes in patient safety. To describe the Web-application Duke Surgery Patient Safety, designed for the anonymous reporting of adverse and near-miss events as well as scheduled reporting to surgeons and hospital administration. SOFTWARE ARCHITECTURE: DSPS was developed primarily using Java language running on a Tomcat server and with MySQL database as its backend. Formal and field usability tests were used to aid in development of DSPS. Extensive experience with DSPS at our institution indicate that DSPS is easy to learn and use, has good speed, provides needed functionality, and is well received by both adverse-event reporters and administrators. This is the first description of an open-source application for reporting patient safety, which allows the distribution of the application to other institutions in addition for its ability to adapt to the needs of different departments. DSPS provides a mechanism for anonymous reporting of adverse events and helps to administer Patient Safety initiatives. The modifiable framework of DSPS allows adherence to evolving national data standards. The open-source design of DSPS permits surgical departments with existing reporting mechanisms to integrate them with DSPS. The DSPS application is distributed under the GNU General Public License.

  7. Advancing perinatal patient safety through application of safety science principles using health IT.

    PubMed

    Webb, Jennifer; Sorensen, Asta; Sommerness, Samantha; Lasater, Beth; Mistry, Kamila; Kahwati, Leila

    2017-12-19

    The use of health information technology (IT) has been shown to promote patient safety in Labor and Delivery (L&D) units. The use of health IT to apply safety science principles (e.g., standardization) to L&D unit processes may further advance perinatal safety. Semi-structured interviews were conducted with L&D units participating in the Agency for Healthcare Research and Quality's (AHRQ's) Safety Program for Perinatal Care (SPPC) to assess units' experience with program implementation. Analysis of interview transcripts was used to characterize the process and experience of using health IT for applying safety science principles to L&D unit processes. Forty-six L&D units from 10 states completed participation in SPPC program implementation; thirty-two (70%) reported the use of health IT as an enabling strategy for their local implementation. Health IT was used to improve standardization of processes, use of independent checks, and to facilitate learning from defects. L&D units standardized care processes through use of electronic health record (EHR)-based order sets and use of smart pumps and other technology to improve medication safety. Units also standardized EHR documentation, particularly related to electronic fetal monitoring (EFM) and shoulder dystocia. Cognitive aids and tools were integrated into EHR and care workflows to create independent checks such as checklists, risk assessments, and communication handoff tools. Units also used data from EHRs to monitor processes of care to learn from defects. Units experienced several challenges incorporating health IT, including obtaining organization approval, working with their busy IT departments, and retrieving standardized data from health IT systems. Use of health IT played an integral part in the planning and implementation of SPPC for participating L&D units. Use of health IT is an encouraging approach for incorporating safety science principles into care to improve perinatal safety and should be incorporated

  8. Critical concerns, solutions and guidelines for use of plastic encapsulated microcircuits for space flight applications

    NASA Technical Reports Server (NTRS)

    Virmani, Nick; Shaw, Jack

    1997-01-01

    Some of the concerns and risk mitigation procedures for using plastic encapsulated microcircuits (PEMs) for space applications are discussed. Despite their advantages, PEMs cannot be implemented in all space applications by replacing military parts numbers with their commercial counterparts in product designs and part lists. The technical and procurement concerns are summarized, and suggestions for high reliability procurements are given. The ability to withstand deleterious environmental effects and to meet mission critical reliability is the key to the successful use of PEMs for space applications.

  9. A study of critical reasoning in online learning: application of the Occupational Performance Process Model.

    PubMed

    Mitchell, Anita Witt; Batorski, Rosemary E

    2009-01-01

    This study examined the effect of an online guided independent study on critical reasoning skills. Twenty-one first-semester Master of Occupational Therapy students completed an online assignment designed to facilitate application of the Occupational Performance Process Model (Fearing & Clark) and kept reflective journals. Data from the journals were analyzed in relation to the three sets of questions, question type and results of the Watson-Glaser Critical Thinking Appraisal (WGCTA). This assignment appeared to be effective for enhancing awareness and use of critical reasoning skills. Differences in patterns of critical reasoning between students with high and low WGCTA scores and results of an inductive analysis of the journal entries are discussed. Future research investigating the types of feedback that effectively facilitate development of critical reasoning and whether students with high and low WGCTA scores might benefit from different types of instruction and/or feedback is recommended. Copyright (c) 2009 John Wiley & Sons, Ltd.

  10. A new technology perspective and engineering tools approach for large, complex and distributed mission and safety critical systems components

    NASA Technical Reports Server (NTRS)

    Carrio, Miguel A., Jr.

    1988-01-01

    Rapidly emerging technology and methodologies have out-paced the systems development processes' ability to use them effectively, if at all. At the same time, the tools used to build systems are becoming obsolescent themselves as a consequence of the same technology lag that plagues systems development. The net result is that systems development activities have not been able to take advantage of available technology and have become equally dependent on aging and ineffective computer-aided engineering tools. New methods and tools approaches are essential if the demands of non-stop and Mission and Safety Critical (MASC) components are to be met.

  11. Guideline for the utilization of commercial grade items in nuclear safety related applications: Final report. [Contains Glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tulay, M.P.; Yurich, F.J.; Schremser, F.M. Jr.

    1988-06-01

    This guideline provides direction for the procurement and use of Commercial Grade Items (CGI)in safety-related applications. It is divided into five major sections. A glossary of terms and definitions, an acronym listing, and seven appendices have been included. The glossary defines terms used in this guideline. In certain instances, the definitions may be unique to this guideline. Identification of acronyms utilized in this guideline is also provided. Section 1 provides a background of the commercial grade item issues facing the nuclear industry. It provides a historical perspective of commercial grade item issues. Section 2 discusses the generic process for themore » acceptance of a commercial grade item for safety-related use. Section 3 defines the four distinct methods used to accept commercial grade items for safety-related applications. Section 4 lists specific references that are identified in this guideline. Section 5 is a bibliography of documents that were considered in developed this guideline, but were not directly referenced in the document.« less

  12. 76 FR 67020 - Railroad Safety Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-28

    ... Device Distraction, Critical Incident, Track Safety Standards, Dark Territory, Passenger Safety, and... railroad safety matters. The RSAC is composed of 54 voting representatives from 31 member organizations...

  13. Possible alternatives to critical elements in coatings for extreme applications

    NASA Astrophysics Data System (ADS)

    Grilli, Maria Luisa; Valerini, Daniele; Piticescu, Radu Robert; Bellezze, Tiziano; Yilmaz, Mehmet; Rinaldi, Antonio; Cuesta-López, Santiago; Rizzo, Antonella

    2018-03-01

    Surface functionalisation and protection have been used since a long time for improving specific properties of materials such as lubrication, water repellence, brightness, and for increasing durability of objects and tools. Among the different kinds of surface treatments used to achieve the required properties, the use of coatings is fundamental to guarantee substrate durability in harsh environments. Extreme working conditions of temperature, pressure, irradiation, wear and corrosion occur in several applications, thus very often requiring bulk material protection by means of coatings. In this study, three main classes of coatings used in extreme conditions are considered: i) hard and superhard coatings for application in machining tools, ii) coatings for high temperatures (thermal barrier coatings), and iii) coatings against corrosion. The presence of critical elements in such coatings (Cr, Y, W, Co, etc.) is analysed and the possibility to use CRMs-free substitutes is reviewed. The role of multilayers and nanocomposites in tailoring coating performances is also discussed for thermal barrier and superhard coatings.

  14. Social Security: Strengthening a Vital Safety Net for Latinos

    ERIC Educational Resources Information Center

    Cruz, Jeff

    2012-01-01

    Since 1935, Social Security has provided a vital safety net for millions of Americans who cannot work because of age or disability. This safety net has been especially critical for Americans of Latino decent, who number more than 50 million or nearly one out of every six Americans. Social Security is critical to Latinos because it is much more…

  15. Foundational workplace safety and health competencies for the emerging workforce☆

    PubMed Central

    Okun, Andrea H.; Guerin, Rebecca J.; Schulte, Paul A.

    2016-01-01

    Introduction Young workers (aged 15–24) suffer disproportionately from workplace injuries, with a nonfatal injury rate estimated to be two times higher than among workers age 25 or over. These workers make up approximately 9% of the U.S. workforce and studies have shown that nearly 80% of high school students work at some point during high school. Although young worker injuries are a pressing public health problem, the critical knowledge and skills needed to prepare youth for safe and healthy work are missing from most frameworks used to prepare the emerging U.S. workforce. Methods A framework of foundational workplace safety and health knowledge and skills (the NIOSH 8 Core Competencies)was developed based on the Health Belief Model (HBM). Results The proposed NIOSH Core Competencies utilize the HBM to provide a framework for foundational workplace safety and health knowledge and skills. An examination of how these competencies and the HBM apply to actions that workers take to protect themselves is provided. The social and physical environments that influence these actions are also discussed. Conclusions The NIOSH 8 Core Competencies, grounded in one of the most widely used health behavior theories, fill a critical gap in preparing the emerging U.S. workforce to be cognizant of workplace risks. Practical applications Integration of the NIOSH 8 Core Competencies into school curricula is one way to ensure that every young person has the foundational workplace safety and health knowledge and skills to participate in, and benefit from, safe and healthy work. National Safety Council and Elsevier Ltd. All rights reserved. PMID:27846998

  16. Smart Roadside System for Driver Assistance and Safety Warnings: Framework and Applications

    PubMed Central

    Jang, Jeong Ah; Kim, Hyun Suk; Cho, Han Byeog

    2011-01-01

    The use of newly emerging sensor technologies in traditional roadway systems can provide real-time traffic services to drivers through Telematics and Intelligent Transport Systems (ITSs). This paper introduces a smart roadside system that utilizes various sensors for driver assistance and traffic safety warnings. This paper shows two road application models for a smart roadside system and sensors: a red-light violation warning system for signalized intersections, and a speed advisory system for highways. Evaluation results for the two services are then shown using a micro-simulation method. In the given real-time applications for drivers, the framework and certain algorithms produce a very efficient solution with respect to the roadway type features and sensor type use. PMID:22164025

  17. Development of a software safety process and a case study of its use

    NASA Technical Reports Server (NTRS)

    Knight, John C.

    1993-01-01

    The goal of this research is to continue the development of a comprehensive approach to software safety and to evaluate the approach with a case study. The case study is a major part of the project, and it involves the analysis of a specific safety-critical system from the medical equipment domain. The particular application being used was selected because of the availability of a suitable candidate system. We consider the results to be generally applicable and in no way particularly limited by the domain. The research is concentrating on issues raised by the specification and verification phases of the software lifecycle since they are central to our previously-developed rigorous definitions of software safety. The theoretical research is based on our framework of definitions for software safety. In the area of specification, the main topics being investigated are the development of techniques for building system fault trees that correctly incorporate software issues and the development of rigorous techniques for the preparation of software safety specifications. The research results are documented. Another area of theoretical investigation is the development of verification methods tailored to the characteristics of safety requirements. Verification of the correct implementation of the safety specification is central to the goal of establishing safe software. The empirical component of this research is focusing on a case study in order to provide detailed characterizations of the issues as they appear in practice, and to provide a testbed for the evaluation of various existing and new theoretical results, tools, and techniques. The Magnetic Stereotaxis System is summarized.

  18. Fault tolerance of artificial neural networks with applications in critical systems

    NASA Technical Reports Server (NTRS)

    Protzel, Peter W.; Palumbo, Daniel L.; Arras, Michael K.

    1992-01-01

    This paper investigates the fault tolerance characteristics of time continuous recurrent artificial neural networks (ANN) that can be used to solve optimization problems. The principle of operations and performance of these networks are first illustrated by using well-known model problems like the traveling salesman problem and the assignment problem. The ANNs are then subjected to 13 simultaneous 'stuck at 1' or 'stuck at 0' faults for network sizes of up to 900 'neurons'. The effects of these faults is demonstrated and the cause for the observed fault tolerance is discussed. An application is presented in which a network performs a critical task for a real-time distributed processing system by generating new task allocations during the reconfiguration of the system. The performance degradation of the ANN under the presence of faults is investigated by large-scale simulations, and the potential benefits of delegating a critical task to a fault tolerant network are discussed.

  19. Pressure Safety Program Implementation at ORNL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lower, Mark; Etheridge, Tom; Oland, C. Barry

    2013-01-01

    The Oak Ridge National Laboratory (ORNL) is a US Department of Energy (DOE) facility that is managed by UT-Battelle, LLC. In February 2006, DOE promulgated worker safety and health regulations to govern contractor activities at DOE sites. These regulations, which are provided in 10 CFR 851, Worker Safety and Health Program, establish requirements for worker safety and health program that reduce or prevent occupational injuries, illnesses, and accidental losses by providing DOE contractors and their workers with safe and healthful workplaces at DOE sites. The regulations state that contractors must achieve compliance no later than May 25, 2007. According tomore » 10 CFR 851, Subpart C, Specific Program Requirements, contractors must have a structured approach to their worker safety and health programs that at a minimum includes provisions for pressure safety. In implementing the structured approach for pressure safety, contractors must establish safety policies and procedures to ensure that pressure systems are designed, fabricated, tested, inspected, maintained, repaired, and operated by trained, qualified personnel in accordance with applicable sound engineering principles. In addition, contractors must ensure that all pressure vessels, boilers, air receivers, and supporting piping systems conform to (1) applicable American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (2004) Sections I through XII, including applicable code cases; (2) applicable ASME B31 piping codes; and (3) the strictest applicable state and local codes. When national consensus codes are not applicable because of pressure range, vessel geometry, use of special materials, etc., contractors must implement measures to provide equivalent protection and ensure a level of safety greater than or equal to the level of protection afforded by the ASME or applicable state or local codes. This report documents the work performed to address legacy pressure vessel deficiencies and

  20. Safety climate and mindful safety practices in the oil and gas industry.

    PubMed

    Dahl, Øyvind; Kongsvik, Trond

    2018-02-01

    The existence of a positive association between safety climate and the safety behavior of sharp-end workers in high-risk organizations is supported by a considerable body of research. Previous research has primarily analyzed two components of safety behavior, namely safety compliance and safety participation. The present study extends previous research by looking into the relationship between safety climate and another component of safety behavior, namely mindful safety practices. Mindful safety practices are defined as the ability to be aware of critical factors in the environment and to act appropriately when dangers arise. Regression analysis was used to examine whether mindful safety practices are, like compliance and participation, promoted by a positive safety climate, in a questionnaire-based study of 5712 sharp-end workers in the oil and gas industry. The analysis revealed that a positive safety climate promotes mindful safety practices. The regression model accounted for roughly 31% of the variance in mindful safety practices. The most important safety climate factor was safety leadership. The findings clearly demonstrate that mindful safety practices are highly context-dependent, hence, manageable and susceptible to change. In order to improve safety climate in a direction which is favorable for mindful safety practices, the results demonstrate that it is important to give the fundamental features of safety climate high priority and in particular that of safety leadership. Copyright © 2017 National Safety Council and Elsevier Ltd. All rights reserved.

  1. Plutonium Critical Mass Curve Comparison to Mass at Upper Subcritical Limit (USL) Using Whisper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alwin, Jennifer Louise; Zhang, Ning

    Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the MCNP ® Monte Carlo radiation transport package. Standard approaches to validation rely on the selection of benchmarks based upon expert judgment. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application or set of applications being analyzed. Using these benchmarks, Whisper computes a calculational margin. Whisper attempts to quantify the margin of subcriticality (MOS) from errors in software and uncertainties in nuclear data. The combination of the Whisper-derived calculational margin and MOS comprise the baseline upper subcritical limit (USL), tomore » which an additional margin may be applied by the nuclear criticality safety analyst as appropriate to ensure subcriticality. A series of critical mass curves for plutonium, similar to those found in Figure 31 of LA-10860-MS, have been generated using MCNP6.1.1 and the iterative parameter study software, WORM_Solver. The baseline USL for each of the data points of the curves was then computed using Whisper 1.1. The USL was then used to determine the equivalent mass for plutonium metal-water system. ANSI/ANS-8.1 states that it is acceptable to use handbook data, such as the data directly from the LA-10860-MS, as it is already considered validated (Section 4.3 4) “Use of subcritical limit data provided in ANSI/ANS standards or accepted reference publications does not require further validation.”). This paper attempts to take a novel approach to visualize traditional critical mass curves and allows comparison with the amount of mass for which the k eff is equal to the USL (calculational margin + margin of subcriticality). However, the intent is to plot the critical mass data along with USL, not to suggest that already accepted handbook data should have new and more rigorous requirements for validation.« less

  2. Validation and Verification (V&V) of Safety-Critical Systems Operating Under Off-Nominal Conditions

    NASA Technical Reports Server (NTRS)

    Belcastro, Christine M.

    2012-01-01

    Loss of control (LOC) remains one of the largest contributors to aircraft fatal accidents worldwide. Aircraft LOC accidents are highly complex in that they can result from numerous causal and contributing factors acting alone or more often in combination. Hence, there is no single intervention strategy to prevent these accidents. Research is underway at the National Aeronautics and Space Administration (NASA) in the development of advanced onboard system technologies for preventing or recovering from loss of vehicle control and for assuring safe operation under off-nominal conditions associated with aircraft LOC accidents. The transition of these technologies into the commercial fleet will require their extensive validation and verification (V&V) and ultimate certification. The V&V of complex integrated systems poses highly significant technical challenges and is the subject of a parallel research effort at NASA. This chapter summarizes the V&V problem and presents a proposed process that could be applied to complex integrated safety-critical systems developed for preventing aircraft LOC accidents. A summary of recent research accomplishments in this effort is referenced.

  3. 75 FR 54593 - Foreign-Trade Zone 272-Lehigh Valley, Pennsylvania, Application for Subzone, Piramal Critical...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-08

    ... Valley, Pennsylvania, Application for Subzone, Piramal Critical Care, Inc. (Inhalation Anesthetics...), grantee of FTZ 272, requesting special-purpose subzone status for the inhalation anesthetics manufacturing.... The facilities are used for the manufacture and distribution of inhalation anesthetics Sevoflurane and...

  4. Laboratory safety and the WHO World Alliance for Patient Safety.

    PubMed

    McCay, Layla; Lemer, Claire; Wu, Albert W

    2009-06-01

    Laboratory medicine has been a pioneer in the field of patient safety; indeed, the College of American Pathology first called attention to the issue in 1946. Delivering reliable laboratory results has long been considered a priority, as the data produced in laboratory medicine have the potential to critically influence individual patients' diagnosis and management. Until recently, most attention on laboratory safety has focused on the analytic stage of laboratory medicine. Addressing this stage has led to significant and impressive improvements in the areas over which laboratories have direct control. However, recent data demonstrate that pre- and post-analytical phases are at least as vulnerable to errors; to further improve patient safety in laboratory medicine, attention must now be focused on the pre- and post-analytic phases, and the concept of patient safety as a multi-disciplinary, multi-stage and multi-system concept better understood. The World Alliance for Patient Safety (WAPS) supports improvement of patient safety globally and provides a potential framework for considering the total testing process.

  5. Cultural differences in dealing with critical incidents.

    PubMed

    Leonhardt, Jörg; Vogt, Joachim

    2009-01-01

    This article discusses the cultural aspects of High Reliability Organizations (HROs), such as air navigation services. HROs must maintain a highly professional safety culture and constantly be prepared to handle crises. The article begins with a general discussion of the concept of organizational culture. The special characteristics of HROs and their safety culture is then described. Finally the article illustrates how Critical Incident Stress Management (CISM) is becoming an ingrained feature of the organizational culture in air traffic control systems. Critical Incident Stress Management is a prevention program that can successfully guard against the negative effects of critical incidents. The CISM program of DFS (Deutsche Flugsicherung) was recently evaluated by the University of Copenhagen. This evaluation not only confirmed the successful prevention of negative effects at the operation's employee level (especially air traffic controllers), but also showed a sustained improvement of its safety culture and its overall organizational performance. The special aspects of cross-cultural crisis intervention and the challenges it faces, as well as the importance of prevention programs, such as CISM, are illustrated using the examples of two aircraft accidents: the crash landing of a calibration aircraft and the Lake Constance air disaster.

  6. Industry Strength Tool and Technology for Automated Synthesis of Safety-Critical Applications from Formal Specifications

    DTIC Science & Technology

    2015-11-01

    28 2.3.4 Input/Output Automata ...various other modeling frameworks such as I/O Automata , Kahn Process Networks, Petri-nets, Multi-dimensional SDF, etc. are also used for designing...Formal Ideally suited to model DSP applications 3 Petri Nets Graphical Formal Used for modeling distributed systems 4 I/O Automata Both Formal

  7. Causal Relationship Analysis of the Patient Safety Culture Based on Safety Attitudes Questionnaire in Taiwan.

    PubMed

    Lee, Yii-Ching; Zeng, Pei-Shan; Huang, Chih-Hsuan; Wu, Hsin-Hung

    2018-01-01

    This study uses the decision-making trial and evaluation laboratory method to identify critical dimensions of the safety attitudes questionnaire in Taiwan in order to improve the patient safety culture from experts' viewpoints. Teamwork climate, stress recognition, and perceptions of management are three causal dimensions, while safety climate, job satisfaction, and working conditions are receiving dimensions. In practice, improvements on effect-based dimensions might receive little effects when a great amount of efforts have been invested. In contrast, improving a causal dimension not only improves itself but also results in better performance of other dimension(s) directly affected by this particular dimension. Teamwork climate and perceptions of management are found to be the most critical dimensions because they are both causal dimensions and have significant influences on four dimensions apiece. It is worth to note that job satisfaction is the only dimension affected by the other dimensions. In order to effectively enhance the patient safety culture for healthcare organizations, teamwork climate, and perceptions of management should be closely monitored.

  8. Causal Relationship Analysis of the Patient Safety Culture Based on Safety Attitudes Questionnaire in Taiwan

    PubMed Central

    Zeng, Pei-Shan; Huang, Chih-Hsuan

    2018-01-01

    This study uses the decision-making trial and evaluation laboratory method to identify critical dimensions of the safety attitudes questionnaire in Taiwan in order to improve the patient safety culture from experts' viewpoints. Teamwork climate, stress recognition, and perceptions of management are three causal dimensions, while safety climate, job satisfaction, and working conditions are receiving dimensions. In practice, improvements on effect-based dimensions might receive little effects when a great amount of efforts have been invested. In contrast, improving a causal dimension not only improves itself but also results in better performance of other dimension(s) directly affected by this particular dimension. Teamwork climate and perceptions of management are found to be the most critical dimensions because they are both causal dimensions and have significant influences on four dimensions apiece. It is worth to note that job satisfaction is the only dimension affected by the other dimensions. In order to effectively enhance the patient safety culture for healthcare organizations, teamwork climate, and perceptions of management should be closely monitored. PMID:29686825

  9. Application of an Informatics-Based Decision-Making Framework and Process to the Assessment of Radiation Safety in Nanotechnology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoover, Mark D.; Myers, David S.; Cash, Leigh J.

    The National Council on Radiation Protection and Measurements (NCRP) has established NCRP Scientific Committee 2-6 to develop a report on the current state of knowledge and guidance for radiation safety programs involved with nanotechnology. Nanotechnology is the understanding and control of matter at the nanoscale, at dimensions between approximately 1 and 100 nanometers, where unique phenomena enable novel applications. While the full report is in preparation, this article presents and applies an informatics-based decision-making framework and process through which the radiation protection community can anticipate that nano-enabled applications, processes, nanomaterials, and nanoparticles are likely to become present or are alreadymore » present in radiation-related activities; recognize specific situations where environmental and worker safety, health, well-being, and productivity may be affected by nano-related activities; evaluate how radiation protection practices may need to be altered to improve protection; control information, interpretations, assumptions, and conclusions to implement scientifically sound decisions and actions; and confirm that desired protection outcomes have been achieved. This generally applicable framework and supporting process can be continuously applied to achieve health and safety at the convergence of nanotechnology and radiation-related activities.« less

  10. Application of an informatics-based decision-making framework and process to the assessment of radiation safety in nanotechnology.

    PubMed

    Hoover, Mark D; Myers, David S; Cash, Leigh J; Guilmette, Raymond A; Kreyling, Wolfgang G; Oberdörster, Günter; Smith, Rachel; Cassata, James R; Boecker, Bruce B; Grissom, Michael P

    2015-02-01

    The National Council on Radiation Protection and Measurements (NCRP) established NCRP Scientific Committee 2-6 to develop a report on the current state of knowledge and guidance for radiation safety programs involved with nanotechnology. Nanotechnology is the understanding and control of matter at the nanoscale, at dimensions between ∼1 and 100 nm, where unique phenomena enable novel applications. While the full report is in preparation, this paper presents and applies an informatics-based decision-making framework and process through which the radiation protection community can anticipate that nano-enabled applications, processes, nanomaterials, and nanoparticles are likely to become present or are already present in radiation-related activities; recognize specific situations where environmental and worker safety, health, well-being, and productivity may be affected by nano-related activities; evaluate how radiation protection practices may need to be altered to improve protection; control information, interpretations, assumptions, and conclusions to implement scientifically sound decisions and actions; and confirm that desired protection outcomes have been achieved. This generally applicable framework and supporting process can be continuously applied to achieve health and safety at the convergence of nanotechnology and radiation-related activities.

  11. Application of an Informatics-Based Decision-Making Framework and Process to the Assessment of Radiation Safety in Nanotechnology

    DOE PAGES

    Hoover, Mark D.; Myers, David S.; Cash, Leigh J.; ...

    2015-01-01

    The National Council on Radiation Protection and Measurements (NCRP) has established NCRP Scientific Committee 2-6 to develop a report on the current state of knowledge and guidance for radiation safety programs involved with nanotechnology. Nanotechnology is the understanding and control of matter at the nanoscale, at dimensions between approximately 1 and 100 nanometers, where unique phenomena enable novel applications. While the full report is in preparation, this article presents and applies an informatics-based decision-making framework and process through which the radiation protection community can anticipate that nano-enabled applications, processes, nanomaterials, and nanoparticles are likely to become present or are alreadymore » present in radiation-related activities; recognize specific situations where environmental and worker safety, health, well-being, and productivity may be affected by nano-related activities; evaluate how radiation protection practices may need to be altered to improve protection; control information, interpretations, assumptions, and conclusions to implement scientifically sound decisions and actions; and confirm that desired protection outcomes have been achieved. This generally applicable framework and supporting process can be continuously applied to achieve health and safety at the convergence of nanotechnology and radiation-related activities.« less

  12. Preharvest food safety.

    PubMed

    Childers, A B; Walsh, B

    1996-07-23

    Preharvest food safety is essential for the protection of our food supply. The production and transport of livestock and poultry play an integral part in the safety of these food products. The goals of this safety assurance include freedom from pathogenic microorganisms, disease, and parasites, and from potentially harmful residues and physical hazards. Its functions should be based on hazard analysis and critical control points from producer to slaughter plant with emphasis on prevention of identifiable hazards rather than on removal of contaminated products. The production goal is to minimize infection and insure freedom from potentially harmful residues and physical hazards. The marketing goal is control of exposure to pathogens and stress. Both groups should have functional hazard analysis and critical control points management programs which include personnel training and certification of producers. These programs must cover production procedures, chemical usage, feeding, treatment practices, drug usage, assembly and transportation, and animal identification. Plans must use risk assessment principles, and the procedures must be defined. Other elements would include preslaughter certification, environmental protection, control of chemical hazards, live-animal drug-testing procedures, and identification of physical hazards.

  13. System safety education focused on industrial engineering

    NASA Technical Reports Server (NTRS)

    Johnston, W. L.; Morris, R. S.

    1971-01-01

    An educational program, designed to train students with the specific skills needed to become safety specialists, is described. The discussion concentrates on application, selection, and utilization of various system safety analytical approaches. Emphasis is also placed on the management of a system safety program, its relationship with other disciplines, and new developments and applications of system safety techniques.

  14. A Teacher Action Research Study: Enhancing Student Critical Thinking Knowledge, Skills, Dispositions, Application and Transfer in a Higher Education Technology Course

    ERIC Educational Resources Information Center

    Phelan, Jack Gordon

    2012-01-01

    This study examined the effects of a critical thinking instructional intervention in a higher education technology course with the purpose of determining the extent to which the intervention enhanced student critical thinking knowledge, skills, dispositions, application and transfer abilities. Historically, critical thinking has been considered…

  15. [Risk management in anesthesia and critical care medicine].

    PubMed

    Eisold, C; Heller, A R

    2017-03-01

    Throughout its history, anesthesia and critical care medicine has experienced vast improvements to increase patient safety. Consequently, anesthesia has never been performed on such a high level as it is being performed today. As a result, we do not always fully perceive the risks involved in our daily activity. A survey performed in Swiss hospitals identified a total of 169 hot spots which endanger patient safety. It turned out that there is a complex variety of possible errors that can only be tackled through consistent implementation of a safety culture. The key elements to reduce complications are continuing staff education, algorithms and standard operating procedures (SOP), working according to the principles of crisis resource management (CRM) and last but not least the continuous work-up of mistakes identified by critical incident reporting systems.

  16. PFP Public Automatic Exchange (PAX) Commercial Grade Item (CGI) Critical Characteristics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WHITE, W.F.

    2000-04-04

    This document specifies the critical characteristics for Commercial Grade Items (CGI) procured for use within the safety envelope of PFP's PAX system as required by HNF-PRO-268 and HNF-PRO-1819. These are the minimum specifications that the equipment must meet in order to properly perform its safety function. There may be several manufacturers or models that meet the critical characteristics for any one item.

  17. A critical assessment of regulatory triggers for products of biotechnology: Product vs. process

    PubMed Central

    McHughen, Alan

    2016-01-01

    ABSTRACT Regulatory policies governing the safety of genetic engineering (rDNA) and the resulting products (GMOs) have been contentious and divisive, especially in agricultural applications of the technologies. These tensions led to vastly different approaches to safety regulation in different jurisdictions, even though the intent of regulations—to assure public and environmental safety—are common worldwide, and even though the international scientific communities agree on the basic principles of risk assessment and risk management. So great are the political divisions that jurisdictions cannot even agree on the appropriate triggers for regulatory capture, whether product or process. This paper reviews the historical policy and scientific implications of agricultural biotechnology regulatory approaches taken by the European Union, USA and Canada, using their respective statutes and regulations, and then critically assesses the scientific underpinnings of each. PMID:27813691

  18. Are your employees sick of hearing about safety? Ways to improve how safety is communicated at your company

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pollari, Roger A.

    2008-06-02

    Companies that care about their employees care about their employees’ safety and will go to great lengths to communicate the importance of working safely. Monthly safety meetings, creative safety contests, safety websites, sharing lessons learned—safety communicators tend to use a variety of methods to distribute procedures and critical safety information to help employees plan and perform work. However, the safety message falls on deaf ears in some cases, especially when employees feel they’re being overloaded with safety information to the point where they are sick of hearing about it. This poses a conundrum for safety communicators: Should they keep pouringmore » on the safety, or should they lighten up? How much is the right amount?« less

  19. Nuclear safety policy working group recommendations on nuclear propulsion safety for the space exploration initiative

    NASA Technical Reports Server (NTRS)

    Marshall, Albert C.; Lee, James H.; Mcculloch, William H.; Sawyer, J. Charles, Jr.; Bari, Robert A.; Cullingford, Hatice S.; Hardy, Alva C.; Niederauer, George F.; Remp, Kerry; Rice, John W.

    1993-01-01

    An interagency Nuclear Safety Working Group (NSPWG) was chartered to recommend nuclear safety policy, requirements, and guidelines for the Space Exploration Initiative (SEI) nuclear propulsion program. These recommendations, which are contained in this report, should facilitate the implementation of mission planning and conceptual design studies. The NSPWG has recommended a top-level policy to provide the guiding principles for the development and implementation of the SEI nuclear propulsion safety program. In addition, the NSPWG has reviewed safety issues for nuclear propulsion and recommended top-level safety requirements and guidelines to address these issues. These recommendations should be useful for the development of the program's top-level requirements for safety functions (referred to as Safety Functional Requirements). The safety requirements and guidelines address the following topics: reactor start-up, inadvertent criticality, radiological release and exposure, disposal, entry, safeguards, risk/reliability, operational safety, ground testing, and other considerations.

  20. 77 FR 48153 - Protection of Stratospheric Ozone: Request for Methyl Bromide Critical Use Exemption Applications...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-13

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OAR-2012-0375, FRL-9715-7] Protection of Stratospheric Ozone: Request for Methyl Bromide Critical Use Exemption Applications for 2015, Deadline Extension... Stratospheric Ozone Information Hotline, 1-800-296-1996; also http://www.epa.gov/ozone/mbr . Technical...

  1. A Critical Examination of Safety Texts: Implications for Trade and Industrial Education.

    ERIC Educational Resources Information Center

    Gregson, James A.

    1996-01-01

    Qualitative content analysis of three texts used to prepare trade and industrial teachers in occupational safety and health examined definitions of health/safety problems, allocation of responsibility, social context, and collective responsibility. Implementing practices from these texts could free teachers from responsibility for negligence and…

  2. Safety-critical event risk associated with cell phone tasks as measured in naturalistic driving studies: A systematic review and meta-analysis.

    PubMed

    Simmons, Sarah M; Hicks, Anne; Caird, Jeff K

    2016-02-01

    A systematic review and meta-analysis of naturalistic driving studies involving estimates of safety-critical event risk associated with handheld device use while driving is described. Fifty-seven studies identified from targeted databases, journals and websites were reviewed in depth, and six were ultimately included. These six studies, published between 2006 and 2014, encompass seven sets of naturalistic driver data and describe original research that utilized naturalistic methods to assess the effects of distracting behaviors. Four studies involved non-commercial drivers of light vehicles and two studies involved commercial drivers of trucks and buses. Odds ratios quantifying safety-critical event (SCE) risk associated with talking, dialing, locating or answering, and texting or browsing were extracted. Stratified meta-analysis of pooled odds ratios was used to estimate SCE risk by distraction type; meta-regression was used to test for sources of heterogeneity. The results indicate that tasks that require drivers to take their eyes off the road, such as dialing, locating a phone and texting, increase SCE risk to a greater extent than tasks that do not require eyes off the road such as talking. Although talking on a handheld device did not increase SCE risk, further research is required to determine whether it indirectly influences SCE risk (e.g., by encouraging other cell phone activities). In addition, a number of study biases and quality issues of naturalistic driving studies are discussed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Risk management modeling and its application in maritime safety

    NASA Astrophysics Data System (ADS)

    Qin, Ting-Rong; Chen, Wei-Jiong; Zeng, Xiang-Kun

    2008-12-01

    Quantified risk assessment (QRA) needs mathematicization of risk theory. However, attention has been paid almost exclusively to applications of assessment methods, which has led to neglect of research into fundamental theories, such as the relationships among risk, safety, danger, and so on. In order to solve this problem, as a first step, fundamental theoretical relationships about risk and risk management were analyzed for this paper in the light of mathematics, and then illustrated with some charts. Second, man-machine-environment-management (MMEM) theory was introduced into risk theory to analyze some properties of risk. On the basis of this, a three-dimensional model of risk management was established that includes: a goal dimension; a management dimension; an operation dimension. This goal management operation (GMO) model was explained and then emphasis was laid on the discussion of the risk flowchart (operation dimension), which lays the groundwork for further study of risk management and qualitative and quantitative assessment. Next, the relationship between Formal Safety Assessment (FSA) and Risk Management was researched. This revealed that the FSA method, which the international maritime organization (IMO) is actively spreading, comes from Risk Management theory. Finally, conclusion were made about how to apply this risk management method to concrete fields efficiently and conveniently, as well as areas where further research is required.

  4. Culture, communication and safety: lessons from the airline industry.

    PubMed

    d'Agincourt-Canning, Lori G; Kissoon, Niranjan; Singal, Mona; Pitfield, Alexander F

    2011-06-01

    Communication is a critical component of effective teamwork and both are essential elements in providing high quality of care to patients. Yet, communication is not an innate skill but a process influenced by internal (personal/cultural values) as well as external (professional roles and hierarchies) factors. To provide illustrative cases, themes and tools for improving communication. Literature review and consensus opinion based on extensive experience. Professional autonomy should be de-emphasized. Tools such as SBAR and simulation are important in communication and teamwork. Tools designed to improve communication and safety in the aviation industry may have applicability to the pediatric intensive care unit.

  5. Safety and Feasibility of a Neuroscience Critical Care Program to Mobilize Patients With Primary Intracerebral Hemorrhage.

    PubMed

    Bahouth, Mona N; Power, Melinda C; Zink, Elizabeth K; Kozeniewski, Kate; Kumble, Sowmya; Deluzio, Sandra; Urrutia, Victor C; Stevens, Robert D

    2018-06-01

    To measure the impact of a progressive mobility program on patients admitted to a neurocritical critical care unit (NCCU) with intracerebral hemorrhage (ICH). The early mobilization of critically ill patients with spontaneous ICH is a challenge owing to the potential for neurologic deterioration and hemodynamic lability in the acute phase of injury. Patients admitted to the intensive care unit have been excluded from randomized trials of early mobilization after stroke. An interdisciplinary working group developed a formalized NCCU Mobility Algorithm that allocates patients to incremental passive or active mobilization pathways on the basis of level of consciousness and motor function. In a quasi-experimental consecutive group comparison, patients with ICH admitted to the NCCU were analyzed in two 6-month epochs, before and after rollout of the algorithm. Mobilization and safety endpoints were compared between epochs. NCCU in an urban, academic hospital. Adult patients admitted to the NCCU with primary intracerebral hemorrhage. Progressive mobilization after stroke using a formalized mobility algorithm. Time to first mobilization. The 2 groups of patients with ICH (pre-algorithm rolllout, n=28; post-algorithm rollout, n=29) were similar on baseline characteristics. Patients in the postintervention group were significantly more likely to undergo mobilization within the first 7 days after admission (odds ratio 8.7, 95% confidence interval 2.1, 36.6; P=.003). No neurologic deterioration, hypotension, falls, or line dislodgments were reported in association with mobilization. A nonsignificant difference in mortality was noted before and after rollout of the algorithm (4% vs 24%, respectively, P=.12). The implementation of a progressive mobility algorithm was safe and associated with a higher likelihood of mobilization in the first week after spontaneous ICH. Research is needed to investigate methods and the timing for the first mobilization in critically ill stroke

  6. Pulsed high-peak-power and single-frequency fibre laser design for LIDAR aircraft safety application

    NASA Astrophysics Data System (ADS)

    Liégeois, Flavien; Vercambre, Clément; Hernandez, Yves; Salhi, Mohamed; Giannone, Domenico

    2006-09-01

    Laser wind velocimeters work by monitoring the Doppler shift induced on the backscattered light by aerosols that are present in the air. Recently there has been a growing interest in the scientific community for developing systems operating at wavelengths near 1.5 μm and based on all-fibre lasers configuration. In this paper, we propose a new all-fibre laser source that is suitable for Doppler velocimetry in aircraft safety applications. The all-fibre laser has been specifically conceived for aircraft safety application. Our prototype has a conveniently narrow linewidth (9 kHz) and is modulated and amplified through an all fibre Master Oscillator Power Amplifier (MOPA) configuration. According to the measurements, we performed the final characteristics of the laser consist in a maximum peak power of 2.7 kW and an energy of 27 μJ energy per pulses of 10 ns at 30 kHz repetition rate. The only limiting factor of these performances is the Stimulated Brillouin Scattering.

  7. Electrospinning as a powerful technique for biomedical applications: a critically selected survey.

    PubMed

    Villarreal-Gómez, Luis Jesús; Cornejo-Bravo, José Manuel; Vera-Graziano, Ricardo; Grande, Daniel

    2016-01-01

    Nowadays, electrospinning has become one of the most versatile, easy, and cost-effective techniques to engineer advanced materials used for many applications, especially in the biomedical and environmental areas. Like the numerous patents around the world, the increasing number of papers witnesses the huge potential of this simple process, and many companies have been emerged during the last years to exploit its innumerable applications. This article presents a critically selected overview of polymers that can be used to produce nanofibers, along with the biomedical applications of the resulting electrospun scaffolds. We have focused on about seven natural and synthetic polymers, but many more can be found in the literature, either as their pristine state or as composites with ceramics, metals, and other polymers. The description of some strategies for nanofiber production, and the characterization used to evaluate their optimization, has been discussed. Finally, several polymers have been recognized as highlights for future work.

  8. 78 FR 45052 - Critical Parts for Airplane Propellers; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-26

    ..., early warning devices, maintenance checks, and other similar equipment or procedures. If items of the..., and maintenance processes for propeller critical parts. An unintentional error was introduced in Sec... transportation, Aircraft, Aviation safety, Safety. The Correcting Amendment In consideration of the foregoing...

  9. Pesticide Safety for Non-Certified Mixers, Loaders and Applicators = Uso Seguro de Pesticidas para Mezcladores, Cargadores y Aplicadores no Certificados.

    ERIC Educational Resources Information Center

    Poli, Bonnie; Fluker, Sam S.

    Written in English and Spanish and completely illustrated, this manual provides basic safety information for pesticide workers. Mixers, loaders, and applicators work with pesticides at their greatest strength and have the highest risk of poisoning. Understanding the pesticide label is the first step to pesticide safety. The words…

  10. Applications of emerging imaging techniques for meat quality and safety detection and evaluation: A review.

    PubMed

    Xiong, Zhenjie; Sun, Da-Wen; Pu, Hongbin; Gao, Wenhong; Dai, Qiong

    2017-03-04

    With improvement in people's living standards, many people nowadays pay more attention to quality and safety of meat. However, traditional methods for meat quality and safety detection and evaluation, such as manual inspection, mechanical methods, and chemical methods, are tedious, time-consuming, and destructive, which cannot meet the requirements of modern meat industry. Therefore, seeking out rapid, non-destructive, and accurate inspection techniques is important for the meat industry. In recent years, a number of novel and noninvasive imaging techniques, such as optical imaging, ultrasound imaging, tomographic imaging, thermal imaging, and odor imaging, have emerged and shown great potential in quality and safety assessment. In this paper, a detailed overview of advanced applications of these emerging imaging techniques for quality and safety assessment of different types of meat (pork, beef, lamb, chicken, and fish) is presented. In addition, advantages and disadvantages of each imaging technique are also summarized. Finally, future trends for these emerging imaging techniques are discussed, including integration of multiple imaging techniques, cost reduction, and developing powerful image-processing algorithms.

  11. Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research☆

    PubMed Central

    Rossi, Simone; Hallett, Mark; Rossini, Paolo M.; Pascual-Leone, Alvaro

    2011-01-01

    This article is based on a consensus conference, which took place in Certosa di Pontignano, Siena (Italy) on March 7–9, 2008, intended to update the previous safety guidelines for the application of transcranial magnetic stimulation (TMS) in research and clinical settings. Over the past decade the scientific and medical community has had the opportunity to evaluate the safety record of research studies and clinical applications of TMS and repetitive TMS (rTMS). In these years the number of applications of conventional TMS has grown impressively, new paradigms of stimulation have been developed (e.g., patterned repetitive TMS) and technical advances have led to new device designs and to the real-time integration of TMS with electroencephalography (EEG), positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). Thousands of healthy subjects and patients with various neurological and psychiatric diseases have undergone TMS allowing a better assessment of relative risks. The occurrence of seizures (i.e., the most serious TMS-related acute adverse effect) has been extremely rare, with most of the few new cases receiving rTMS exceeding previous guidelines, often in patients under treatment with drugs which potentially lower the seizure threshold. The present updated guidelines review issues of risk and safety of conventional TMS protocols, address the undesired effects and risks of emerging TMS interventions, the applications of TMS in patients with implanted electrodes in the central nervous system, and safety aspects of TMS in neuroimaging environments. We cover recommended limits of stimulation parameters and other important precautions, monitoring of subjects, expertise of the rTMS team, and ethical issues. While all the recommendations here are expert based, they utilize published data to the extent possible. PMID:19833552

  12. Automated implementation of rule-based expert systems with neural networks for time-critical applications

    NASA Technical Reports Server (NTRS)

    Ramamoorthy, P. A.; Huang, Song; Govind, Girish

    1991-01-01

    In fault diagnosis, control and real-time monitoring, both timing and accuracy are critical for operators or machines to reach proper solutions or appropriate actions. Expert systems are becoming more popular in the manufacturing community for dealing with such problems. In recent years, neural networks have revived and their applications have spread to many areas of science and engineering. A method of using neural networks to implement rule-based expert systems for time-critical applications is discussed here. This method can convert a given rule-based system into a neural network with fixed weights and thresholds. The rules governing the translation are presented along with some examples. We also present the results of automated machine implementation of such networks from the given rule-base. This significantly simplifies the translation process to neural network expert systems from conventional rule-based systems. Results comparing the performance of the proposed approach based on neural networks vs. the classical approach are given. The possibility of very large scale integration (VLSI) realization of such neural network expert systems is also discussed.

  13. Vehicle-to-infrastructure (V2I) safety applications performance requirements, vol. 2, curve speed warning (CSW).

    DOT National Transportation Integrated Search

    2015-08-01

    This document is the second of a seven volume report that describe the Performance Requirements for the connected vehicle vehicle-to-infrastructure (V2I) safety applications developed for the U.S. Department of Transportation (U.S. DOT). This volume ...

  14. Application of the Actor-Critic Architecture to Functional Electrical Stimulation Control of a Human Arm.

    PubMed

    Thomas, Philip; Branicky, Michael; van den Bogert, Antonie; Jagodnik, Kathleen

    2009-01-01

    Clinical tests have shown that the dynamics of a human arm, controlled using Functional Electrical Stimulation (FES), can vary significantly between and during trials. In this paper, we study the application of the actor-critic architecture, with neural networks for the both the actor and the critic, as a controller that can adapt to these changing dynamics of a human arm. Development and tests were done in simulation using a planar arm model and Hill-based muscle dynamics. We begin by training it using a Proportional Derivative (PD) controller as a supervisor. We then make clinically relevant changes to the dynamics of the arm and test the actor-critic's ability to adapt without supervision in a reasonable number of episodes. Finally, we devise methods for achieving both rapid learning and long-term stability.

  15. Meeting the global demand of sports safety: the intersection of science and policy in sports safety.

    PubMed

    Timpka, Toomas; Finch, Caroline F; Goulet, Claude; Noakes, Tim; Yammine, Kaissar

    2008-01-01

    Sports and physical activity are transforming, and being transformed by, the societies in which they are practised. From the perspectives of both competitive and non-competitive sports, the complexity of their integration into today's society has led to neither sports federations nor governments being able to manage the safety problem alone. In other words, these agencies, whilst promoting sport and physical activity, deliver policy and practices in an uncoordinated way that largely ignores the need for a concurrent overall policy for sports safety. This article reviews and analyses the possibility of developing an overall sports safety policy from a global viewpoint. Firstly, we describe the role of sports in today's societies and the context within which much sport is delivered. We then discuss global issues related to injury prevention and safety in sports, with practical relevance to this important sector, including an analysis of critical policy issues necessary for the future development of the area and significant safety gains for all. We argue that there is a need to establish the sports injury problem as a critical component of general global health policy agendas, and to introduce sports safety as a mandatory component of all sustainable sports organizations. We conclude that the establishment of an explicit intersection between science and policy making is necessary for the future development of sports and the necessary safety gains required for all participants around the world. The Safe Sports International safety promotion programme is outlined as an example of an international organization active within this arena.

  16. Development of a highway safety fundamental course.

    DOT National Transportation Integrated Search

    2015-05-01

    Although the need for road safety education was first recognized in the 1960s, it has become an increasingly urgent issue : in recent years. To fulfill the hefty goal set up by the AASHTO Highway Safety Strategy and by state DOTS, it is critical : to...

  17. European perspectives of food safety.

    PubMed

    Bánáti, Diána

    2014-08-01

    Food safety has been a growing concern among European Union (EU) citizens over the last decades. Despite the fact that food has never been safer, consumers are considerably uncertain and increasingly critical about the safety of their food. The introduction of new principles, such as the primary responsibility of producers, traceability, risk analysis, the separation of risk assessment and risk management provided a more transparent, science-based system in Europe, which can help to restore consumers' lost confidence. The present EU integrated approach to food safety 'from farm to fork' aims to assure a high level of food safety within the EU. © 2014 Society of Chemical Industry.

  18. Space-Based Range Safety and Future Space Range Applications

    NASA Technical Reports Server (NTRS)

    Whiteman, Donald E.; Valencia, Lisa M.; Simpson, James C.

    2005-01-01

    The National Aeronautics and Space Administration (NASA) Space-Based Telemetry and Range Safety (STARS) study is a multiphase project to demonstrate the performance, flexibility and cost savings that can be realized by using space-based assets for the Range Safety [global positioning system (GPS) metric tracking data, flight termination command and range safety data relay] and Range User (telemetry) functions during vehicle launches and landings. Phase 1 included flight testing S-band Range Safety and Range User hardware in 2003 onboard a high-dynamic aircraft platform at Dryden Flight Research Center (Edwards, California, USA) using the NASA Tracking and Data Relay Satellite System (TDRSS) as the communications link. The current effort, Phase 2, includes hardware and packaging upgrades to the S-band Range Safety system and development of a high data rate Ku-band Range User system. The enhanced Phase 2 Range Safety Unit (RSU) provided real-time video for three days during the historic Global Flyer (Scaled Composites, Mojave, California, USA) flight in March, 2005. Additional Phase 2 testing will include a sounding rocket test of the Range Safety system and aircraft flight testing of both systems. Future testing will include a flight test on a launch vehicle platform. This paper discusses both Range Safety and Range User developments and testing with emphasis on the Range Safety system. The operational concept of a future space-based range is also discussed.

  19. Space-Based Range Safety and Future Space Range Applications

    NASA Technical Reports Server (NTRS)

    Whiteman, Donald E.; Valencia, Lisa M.; Simpson, James C.

    2005-01-01

    The National Aeronautics and Space Administration Space-Based Telemetry and Range Safety study is a multiphase project to demonstrate the performance, flexibility and cost savings that can be realized by using space-based assets for the Range Safety (global positioning system metric tracking data, flight termination command and range safety data relay) and Range User (telemetry) functions during vehicle launches and landings. Phase 1 included flight testing S-band Range Safety and Range User hardware in 2003 onboard a high-dynamic aircraft platform at Dryden Flight Research Center (Edwards, California) using the NASA Tracking and Data Relay Satellite System as the communications link. The current effort, Phase 2, includes hardware and packaging upgrades to the S-band Range Safety system and development of a high data rate Ku-band Range User system. The enhanced Phase 2 Range Safety Unit provided real-time video for three days during the historic GlobalFlyer (Scaled Composites, Mojave, California) flight in March, 2005. Additional Phase 2 testing will include a sounding rocket test of the Range Safety system and aircraft flight testing of both systems. Future testing will include a flight test on a launch vehicle platform. This report discusses both Range Safety and Range User developments and testing with emphasis on the Range Safety system. The operational concept of a future space-based range is also discussed.

  20. Efficacy and safety of novel antipsychotics: a critical review.

    PubMed

    Balestrieri, Matteo; Vampini, Claudio; Bellantuono, Cesario

    2000-10-01

    Efficacy and safety of novel antipsychotic (AP) drugs (amisulpride, olanzapine, quetiapine, ziprasidone and zotepine) have been reviewed. Data on their antipsychotic efficacy and side effects profile have been evaluated only on the basis of controlled trials so far published. Overall, all these drugs have shown an antipsychotic efficacy on positive symptoms of schizophrenia similar to that of the conventional AP drugs. On negative symptoms, all novel AP drugs, except quetiapine and ziprasidone, demonstrated a better efficacy than haloperidol. Long-term efficacy of these AP drugs in the maintenance treatment of schizophrenia needs to be explored by further, better-designed, epidemiological studies. The safety profile shows that the novel AP drugs are generally well-tolerated and induce significantly less acute extrapyramidal side effects in comparison with haloperidol. Some methodological flaws in the experimental design of the clinical trials analysed are discussed. Although these novel AP drugs have potential clinical advantages, a number of relevant questions still remain to be addressed, in order to establish the impact of these drugs in the overall treatment of schizophrenia. Copyright 2000 John Wiley & Sons, Ltd.