Sample records for safety fire protection

  1. Safety survey report EBR-II safety survey, ANL-west health protection, industrial safety and fire protection survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dunbar, K.A.

    1972-01-10

    A safety survey covering the disciplines of Reactor Safety, Nuclear Criticality Safety, Health Protection and Industrial Safety and Fire Protection was conducted at the ANL-West EBR-II FEF Complex during the period January 10-18, 1972. In addition, the entire ANL-West site was surveyed for Health Protection and Industrial Safety and Fire Protection. The survey was conducted by members of the AEC Chicago Operations Office, a member of RDT-HQ and a member of the RDT-ID site office. Eighteen recommendations resulted from the survey, eleven in the area of Industrial Safety and Fire Protection, five in the area of Reactor Safety and twomore » in the area of Nuclear Criticality Safety.« less

  2. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  3. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  4. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  5. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....235-71 Safety, health, and fire protection. As prescribed in 2035.70(a)(2), the contracting officer... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Safety, health, and fire..., Health, and Fire Protection (JAN 1993) The contractor shall take all reasonable precautions in the...

  6. Fire Safety Educational Material.

    ERIC Educational Resources Information Center

    Cohn, Bert M.

    The state of the art of home fire safety educational material was reviewed to prepare a bibliography of home fire safety educational materials available from major public and private sources. Sources contacted were: National Fire Protection Association, National Safety Council, U.S. government agencies, private publishers and film distributors,…

  7. 48 CFR 2052.235-71 - Safety, health, and fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... performance of the work under this contract to protect the health and safety of its employees and of members... hazards to life and property. The contractor shall comply with all applicable health, safety, and fire... an order stopping all or any part of the work. Thereafter, a start work order for resumption of work...

  8. 49 CFR 193.2801 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2801 Section 193.2801...: FEDERAL SAFETY STANDARDS Fire Protection § 193.2801 Fire protection. Each operator must provide and maintain fire protection at LNG plants according to sections 9.1 through 9.7 and section 9.9 of NFPA 59A...

  9. Aircraft fire safety research

    NASA Technical Reports Server (NTRS)

    Botteri, Benito P.

    1987-01-01

    During the past 15 years, very significant progress has been made toward enhancing aircraft fire safety in both normal and hostile (combat) operational environments. Most of the major aspects of the aircraft fire safety problem are touched upon here. The technology of aircraft fire protection, although not directly applicable in all cases to spacecraft fire scenarios, nevertheless does provide a solid foundation to build upon. This is particularly true of the extensive research and testing pertaining to aircraft interior fire safety and to onboard inert gas generation systems, both of which are still active areas of investigation.

  10. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Fire protection. 1926.150 Section 1926.150 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.150 Fire protection. (a) General requirements. (1) The employer shall be responsible for the development of a fire...

  11. Fire Protection in Educational Occupancies.

    ERIC Educational Resources Information Center

    Gervais, Romeo P.

    2000-01-01

    Discusses the origins of school fires and the components of the fire protection code called the Life Safety Code (LSC). Three of the following LSC requirements are described: means of egress; protection from hazards; and fire suppression and alarm systems. Information on who starts fires is highlighted along with preventive measures. (GR)

  12. Risks, designs, and research for fire safety in spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.; Urban, David

    1991-01-01

    Current fire protection for spacecraft relies mainly on fire prevention through the use of nonflammable materials and strict storage controls of other materials. The Shuttle also has smoke detectors and fire extinguishers, using technology similar to aircraft practices. While experience has shown that the current fire protection is adequate, future improvements in fire safety technology to meet the challenges of long duration space missions, such as the Space Station Freedom, are essential. All spacecraft fire protection systems, however, must deal with the unusual combustion characteristics and operational problems in the low gravity environment. The features of low gravity combustion that affect spacecraft fire safety, and the issues in fire protection for Freedom that must be addressed eventually to provide effective and conservative fire protection systems are discussed.

  13. Protection and Safety.

    ERIC Educational Resources Information Center

    American School Board Journal, 1964

    1964-01-01

    Several aspects of school safety and protection are presented for school administrators and architects. Among those topics discussed are--(1) life safety, (2) vandalism controlled through proper design, (3) personal protective devices, and (4) fire alarm systems. Another critical factor in providing a complete school safety program is proper…

  14. What's Your Fire Safety IQ?

    ERIC Educational Resources Information Center

    PTA Today, 1992

    1992-01-01

    The National Fire Protection Association offers a quiz on fire safety designed to help people learn about the major fire dangers and change the way they respond to them. Recommends that families sit down and take the quiz together, focusing on the correct answers provided. (SM)

  15. 76 FR 70885 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-16

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 59 RIN 2900-AN57 Updating Fire Safety Standards AGENCY... Fire Protection Association (NFPA) 101. This rule helps ensure the safety of veterans in the affected... publications are: NFPA 10, Standard for Portable Fire Extinguishers; NFPA 99, Standard for Health Care...

  16. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  17. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard...

  18. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 1 2013-07-01 2013-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  19. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  20. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 1 2012-07-01 2012-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  1. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  2. 40 CFR 30.18 - Hotel and motel fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 1 2011-07-01 2011-07-01 false Hotel and motel fire safety. 30.18... EDUCATION, HOSPITALS, AND OTHER NON-PROFIT ORGANIZATIONS Pre-Award Requirements § 30.18 Hotel and motel fire safety. The Hotel and Motel Fire Safety Act of 1990 (Public Law 101-391) establishes a number of fire...

  3. Fight Fire with These Safety Strategies.

    ERIC Educational Resources Information Center

    Jackson, Lisa M.

    1998-01-01

    Provides expert guidelines on ways to keep schools and children safe from building fires, such as maintenance of exits for easy egress in emergencies, maintaining fire-protection systems, and utilizing evacuation planning and drilling. Highlights fire-safety ideas as part of school-building and renovation projects. (GR)

  4. Special report. Revising your fire safety plans.

    PubMed

    1993-12-01

    Every hospital has a fire safety plan, although some fail to update their plans when circumstances change, such as when the facility is refurbished or new fire protection equipment is added, or when new wings bring in additional patients and staff. Others may fail to develop new education programs to heighten staff awareness of what is expected of them during a fire and to train employees to meet those expectations. In this report, we'll examine the new fire safety plans at two Massachusetts hospitals and the revisions they made to address these issues. We'll offer suggestions for effectively evaluating and revising your own fire safety plans.

  5. Ten Fire Safety Tips for Schools.

    ERIC Educational Resources Information Center

    Lake, James D.

    1999-01-01

    Provides 10 basic tips, compiled from the National Fire Protection Association's Life Safety Code 101, to ensure that educational facilities are fire safe. Tips include use of frequent and unexpected fire drills, limiting wall space of student artwork and teaching materials, being alert to preventing arson, planning speedy and safe emergency…

  6. Fire safety

    Treesearch

    Robert H. White; Mark A. Dietenberger

    1999-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Since basic data on fire behavior of wood products...

  7. 49 CFR 193.2611 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Fire protection. 193.2611 Section 193.2611 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY LIQUEFIED NATURAL GAS FACILITIES...

  8. 42 CFR 403.744 - Condition of participation: Life safety from fire.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 2 2014-10-01 2014-10-01 false Condition of participation: Life safety from fire... safety from fire. (a) General. An RNHCI must meet the following conditions: (1) Except as otherwise... Safety Code of the National Fire Protection Association. The Director of the Office of the Federal...

  9. Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Margle, Janice M. (Editor)

    1987-01-01

    Fire detection, fire standards and testing, fire extinguishment, inerting and atmospheres, fire-related medical science, aircraft fire safety, Space Station safety concerns, microgravity combustion, spacecraft material flammability testing, and metal combustion are among the topics considered.

  10. Passive fire protection--a vital safety role.

    PubMed

    MacInnes, Callum; Rankin, Richard

    2012-06-01

    Callum Maclnnes BSc (Hons), AIFireE, an engineer at WSP UK--part of a global design engineering and management consultancy group specialising in property, transport and infrastructure, industry and environment projects--and his colleague, senior engineer, Richard Rankin CEng MEng (Hons) MIFireE, discuss the importance of passive fire protection in healthcare premises at a time when, due particularly to the difficult financial climate, many hospitals are undergoing upgrading and refurbishment, potentially affording an ideal opportunity to ensure that proper fire compartmentation measures are in place.

  11. 29 CFR Appendix A to Subpart L of... - Fire Protection

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the International Fire Service Training Association, the National Fire Protection Association (NFPA-1041), the International Society of Fire Service Instructors and other fire training sources be... planning, and safety practices. It is again suggested that fire service training sources be consulted for...

  12. NASA safety manual. Volume 9: Fire protection

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Requirements are identified and guidelines are provided for implementing a comprehensive fire protection program. These requirements and guidelines are applicable to NASA headquarters and field installations. Portions also can be applied to NASA contractor operations within the scope of the contract.

  13. Comparing the performance of residential fire sprinklers with other life-safety technologies.

    PubMed

    Butry, David T

    2012-09-01

    Residential fire sprinklers have long proven themselves as life-safety technologies to the fire service community. Yet, about 1% of all one- and two-family dwelling fires occur in homes protected by sprinklers. It has been argued that measured sprinkler performance has ignored factors confounding the relationship between sprinkler use and performance. In this analysis, sprinkler performance is measured by comparing 'like' structure fires, while conditioning on smoke detection technology and neighborhood housing and socioeconomic conditions, using propensity score matching. Results show that residential fire sprinklers protect occupant and firefighter health and safety, and are comparable to other life-safety technologies. Published by Elsevier Ltd.

  14. 29 CFR 1926.24 - Fire protection and prevention.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION General Safety and Health... and maintenance of an effective fire protection and prevention program at the job site throughout all...

  15. Risks and issues in fire safety on the Space Station

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.

  16. Fire Safety - Multiple Languages

    MedlinePlus

    ... Arabic (العربية) Expand Section Fire Safety at Home - English PDF Fire Safety at Home - العربية (Arabic) PDF ... Bosnian (bosanski) Expand Section Fire Safety at Home - English PDF Fire Safety at Home - bosanski (Bosnian) PDF ...

  17. How to Escape a Home Fire (Take This Safety Quiz).

    ERIC Educational Resources Information Center

    PTA Today, 1994

    1994-01-01

    A checklist/safety quiz from the National Fire Protection Association examines individual knowledge of how to escape if a home fire breaks out. The organization recommends that every household develop a fire escape plan and practice it at least twice a year. (SM)

  18. Spacecraft Fire Safety: A Human Space Flight Program Perspective

    NASA Technical Reports Server (NTRS)

    Pedley, Michael D.

    2003-01-01

    This paper presents viewgraphs on the International Space Station's fire safety program from a human space flight perspective. The topics include: 1) Typical Manned Spacecraft Materials; 2) Typical Flammable Hardware Protection; 3) Materials Flammability; 4) Fire Retardants; 5) Nonflammable Foam Cushion Material; 6) Electrical Wire and Cable; 7) Russian Solid-Fuel Oxygen Generator (SFOG); 8) GOX Ignition Mechanisms; 9) Fire Detection; and 10) Fire Suppression.

  19. Applications of Living Fire PRA models to Fire Protection Significance Determination Process in Taiwan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De-Cheng, Chen; Chung-Kung, Lo; Tsu-Jen, Lin

    2004-07-01

    The living fire probabilistic risk assessment (PRA) models for all three operating nuclear power plants (NPPs) in Taiwan had been established in December 2000. In that study, a scenario-based PRA approach was adopted to systematically evaluate the fire and smoke hazards and associated risks. Using these fire PRA models developed, a risk-informed application project had also been completed in December 2002 for the evaluation of cable-tray fire-barrier wrapping exemption. This paper presents a new application of the fire PRA models to fire protection issues using the fire protection significance determination process (FP SDP). The fire protection issues studied may involvemore » the selection of appropriate compensatory measures during the period when an automatic fire detection or suppression system in a safety-related fire zone becomes inoperable. The compensatory measure can either be a 24-hour fire watch or an hourly fire patrol. The living fire PRA models were used to estimate the increase in risk associated with the fire protection issue in terms of changes in core damage frequency (CDF) and large early release frequency (LERF). In compliance with SDP at-power and the acceptance guidelines specified in RG 1.174, the fire protection issues in question can be grouped into four categories; red, yellow, white and green, in accordance with the guidelines developed for FD SDP. A 24-hour fire watch is suggested only required for the yellow condition, while an hourly fire patrol may be adopted for the white condition. More limiting requirement is suggested for the red condition, but no special consideration is needed for the green condition. For the calculation of risk measures, risk impacts from any additional fire scenarios that may have been introduced, as well as more severe initiating events and fire damages that may accompany the fire protection issue should be considered carefully. Examples are presented in this paper to illustrate the evaluation process

  20. Vehicle fires and fire safety in tunnels

    DOT National Transportation Integrated Search

    2002-09-20

    Tunnels present what is arguably the most hazardous environment, from the point of view of fire safety, that members of the public ever experience. The fire safety design of tunnels is carried out by tunnel engineers on the basis of a potential fire ...

  1. Fire Safety Technician

    ERIC Educational Resources Information Center

    Moore, Pam

    2007-01-01

    Fire protection is one of the most important considerations in the construction and operation of industrial plants and commercial buildings. Fire insurance rates are determined by fire probability factors, such as the type of construction, ease of transporting personnel, and the quality and quantity of fire protection equipment available. Because…

  2. DOE Fire Protection Handbook, Volume I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Department of Energy (DOE) Fire Protection Program is delineated in a number of source documents including; the Code of Federal Regulations (CFR), DOE Policy Statements and Orders, DOE and national consensus standards (such as those promulgated by the National Fire Protection Association), and supplementary guidance, This Handbook is intended to bring together in one location as much of this material as possible to facilitate understanding and ease of use. The applicability of any of these directives to individual Maintenance and Operating Contractors or to given facilities and operations is governed by existing contracts. Questions regarding applicability should be directedmore » to the DOE Authority Having Jurisdiction for fire safety. The information provided within includes copies of those DOE directives that are directly applicable to the implementation of a comprehensive fire protection program. They are delineated in the Table of Contents. The items marked with an asterisk (*) are included on the disks in WordPerfect 5.1 format, with the filename noted below. The items marked with double asterisks are provided as hard copies as well as on the disk. For those using MAC disks, the files are in Wordperfect 2.1 for MAC.« less

  3. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  4. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Subpart P to Part 1915 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH... Fire Protection in Shipyard Employment Pt. 1915, Subpt. P, App. A Appendix A to Subpart P to Part 1915... fire. D. Potential ignition sources for fires and how to control them. E. Types of fire protection...

  5. Smoke Detection: Critical Element of a University Residential Fire Safety Program.

    ERIC Educational Resources Information Center

    Robinson, Donald A.

    1979-01-01

    A program at the University of Massachusetts/Amherst to assess the fire protection needs of its residential system is described. The study culminated in a multiphase fire safety improvement plan. (JMF)

  6. Teaching About Fire Safety.

    ERIC Educational Resources Information Center

    Brady, Holly; Arnold, Anne Jurmu

    1982-01-01

    This unit on fire safety teaches students how to act in or during a fire and presents fire prevention measures that students can implement at home. Two reproducible masters concerning fire safety and prevention are presented along with class activities, student reading resources, and organizations and companies that offer classroom materials about…

  7. 76 FR 70414 - National Fire Protection Association (NFPA) Proposes To Revise Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Protection... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its fire safety codes and standards and requests proposals from the public to...

  8. Safety in the Chemical Laboratory: Fire Safety and Fire Control in the Chemistry Laboratory.

    ERIC Educational Resources Information Center

    Wilbraham, A. C.

    1979-01-01

    Discusses fire safety and fire control in the chemistry laboratory. The combustion process, extinguishing equipment, extinguisher maintenance and location, and fire safety and practices are included. (HM)

  9. Fire! Fire Prevention and Safety: A Teacher's Handbook.

    ERIC Educational Resources Information Center

    New York City Board of Education, Brooklyn, NY. Div. of Educational Planning and Support.

    In this curriculum guide, guidelines for teaching children about fire safety and related topics and activities representing an interdisciplinary approach to fire safety are outlined. Major fire hazards and methods of dealing with them are described. Possible sites for field trips and films relating to fire are listed. The rules of the New York…

  10. [Protecting Safety During Dust Fires and Dust Explosions - The Example of the Formosa Fun Coast Water Park Accident].

    PubMed

    Hsieh, Ming-Hong; Wu, Jia-Wun; Li, Ya-Cing; Tang, Jia-Suei; Hsieh, Chun-Chien

    2016-02-01

    This paper will explore the fire and explosion characteristics of cornstarch powder as well as strategies for protecting the safety of people who are involved a dust fire or dust explosion. We discuss the 5 elements of dust explosions and conduct tests to analyze the fire and explosion characteristics of differently colored powders (yellow, golden yellow, pink, purple, orange and green). The results show that, while all of the tested powders were difficult to ignite, low moisture content was associated with significantly greater risks of ignition and flame spread. We found the auto-ignition temperature (AIT) of air-borne cornstarch powder to be between 385°C and 405°C, with yellow-colored cornstarch powder showing the highest AIT and pink-colored cornstarch powder showing the lowest AIT. The volume resistivity of all powder samples was approximately 108 Ω.m, indicating that they were nonconductive. Lighters and cigarettes are effective ignition sources, as their lit temperatures are higher than the AIT of cornstarch powder. In order to better protect the safety of individuals at venues where cornstarch powder is released, explosion control measures such as explosion containment facilities, vents, and explosion suppression and isolation devices should be installed. Furthermore, employees that work at these venues should be better trained in explosion prevention and control measures. We hope this article is a reminder to the public to recognize the fire and explosion characteristics of flammable powders as well as the preventive and control measures for dust explosions.

  11. Fire safety of wood construction

    Treesearch

    Robert H. White; Mark A. Dietenberger

    2010-01-01

    Fire safety is an important concern in all types of construction. The high level of national concern for fire safety is reflected in limitations and design requirements in building codes. These code requirements and related fire performance data are discussed in the context of fire safety design and evaluation in the initial section of this chapter. Because basic data...

  12. Fire Safety in Extraterrestrial Environments

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1998-01-01

    Despite rigorous fire-safety policies and practices, fire incidents are possible during lunar and Martian missions. Fire behavior and hence preventive and responsive safety actions in the missions are strongly influenced by the low-gravity environments in flight and on the planetary surfaces. This paper reviews the understanding and key issues of fire safety in the missions, stressing flame spread, fire detection, suppression, and combustion performance of propellants produced from Martian resources.

  13. Fire safety practices in the Shuttle and the Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1993-01-01

    The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.

  14. Wildland Fire Research: Water Supply and Ecosystem Protection

    EPA Pesticide Factsheets

    Research is critical to better understand how fires affect water quality and supply and the overall health of an ecosystem. This information can be used to protect the safety of drinking water and assess the vulnerability of water supplies.

  15. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    PubMed

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P < 0.0001). The exact 95% confidence interval for absolute risk reduction of fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  16. The three Rs of fire safety, emergency action, and fire prevention planning: promoting safety at the worksite.

    PubMed

    Thompson, Marcella R

    2003-04-01

    Fire safety is of paramount importance for everyone. In many workplaces, the occupational health nurse's scope of practice encompasses safety related activities. Included within this role is the responsibility for fire safety, emergency action, and fire prevention planning. The Three Rs of fire safety, emergency action, and fire prevention plans are rules, responsibilities, and resources. Myriad building and fire safety codes, regulations, and standards exist with which an employer must comply. An employer's responsibility for installing, testing, inspecting, and maintaining fire safety related equipment is extensive. Emergency action and fire prevention planning begins with conducting a detailed physical survey and preparing site maps. It includes making key policy decisions, writing procedures, and training employees in those procedures by practicing and executing site drills. The best resources available for emergency planning are the local fire department and the property insurer. Planning ahead means an efficient emergency response if disaster strikes. It saves lives, limits property damage, and preserves the environment.

  17. Program for developing and implementing a new approach to designing for fire safety in buildings

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The traditional method of providing for fire safety in buildings through reliance on codes and standards that prescribe specific measures to be taken in the design and construction of buildings to minimize the potential for a fire occurring and to protect property and life should a fire occur was evaluated. A new approach to designing for fire safety in buildings is outlined.

  18. [Considering the current state of fire safety in Taiwan's care environment from the perspective of the nation's worst recent hospital fire].

    PubMed

    Tseng, Wei-Wen; Shih, Chung-Liang; Chien, Shen-Wen

    2013-04-01

    Taiwan's worst hospital fire in history on October 23rd, 2012 at Sinying Hospital's Bei-Men Branch resulted in 13 elderly patient deaths and over 70 injuries. The heavy casualties were due in part to the serious condition of patients. Some patients on life-support machines were unable to move or be moved. This disaster highlights the issue of fire safety in small-scale hospitals that have transformed existing hospital space into special care environments for elderly patients. Compared with medical centers and general hospitals, these small-scale health facilities are ill equipped to deal properly with fire safety management and emergency response issues due to inadequate fire protection facilities, fire safety equipment, and human resources. Small-scale facilities that offer health care and medical services to mostly immobile patients face fire risks that differ significantly from general health care facilities. This paper focuses on fire risks in small-scale facilities and suggests a strategy for fire prevention and emergency response procedures, including countermeasures for fire risk assessment, management, and emergency response, in order to improve fire safety at these institutions in Taiwan.

  19. Fire safety applications for spacecraft

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Olson, Sandra L.

    1989-01-01

    Fire safety for spacecraft is reviewed by first describing current practices, many of which are adapted directly from aircraft. Then, current analyses and experimental knowledge in low-gravity combustion, with implications for fire safety are discussed. In orbiting spacecraft, the detection and suppression of flames are strongly affected by the large reduction in buoyant flows under low gravity. Generally, combustion intensity is reduced in low gravity. There are some notable exceptions, however, one example being the strong enhancement of flames by low-velocity ventilation flows in space. Finally, the future requirements in fire safety, particularly the needs of long-duration space stations in fire prevention, detection, extinguishment, and atmospheric control are examined. The goal of spacecraft fire-safety investigations is the establishment of trade-offs that promote maximum safety without hampering the useful human and scientific activities in space.

  20. Fire Protection Specialist, Blocks I, II, & III, 17-2. Military Curriculum Materials for Vocational and Technical Education.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This military-developed text contains the first three blocks of a five-block course for use in training fire protection specialists. Covered in the individual volumes are the following topics: fire protection objectives and responsibilities (fire protection and occupational safety, extinguishing agents, principles and theory of combustion, natural…

  1. Fire safety distances for open pool fires

    NASA Astrophysics Data System (ADS)

    Sudheer, S.; Kumar, Lokendra; Manjunath, B. S.; Pasi, Amit; Meenakshi, G.; Prabhu, S. V.

    2013-11-01

    Fire accidents that carry huge loss with them have increased in the previous two decades than at any time in the history. Hence, there is a need for understanding the safety distances from different fires with different fuels. Fire safety distances are computed for different open pool fires. Diesel, gasoline and hexane are used as fuels for circular pool diameters of 0.5 m, 0.7 m and 1.0 m. A large square pool fire of 4 m × 4 m is also conducted with diesel as a fuel. All the prescribed distances in this study are purely based on the thermal analysis. IR camera is used to get the thermal images of pool fires and there by the irradiance at different locations is computed. The computed irradiance is presented with the threshold heat flux limits for human beings.

  2. Quantitative assessment of building fire risk to life safety.

    PubMed

    Guanquan, Chu; Jinhua, Sun

    2008-06-01

    This article presents a quantitative risk assessment framework for evaluating fire risk to life safety. Fire risk is divided into two parts: probability and corresponding consequence of every fire scenario. The time-dependent event tree technique is used to analyze probable fire scenarios based on the effect of fire protection systems on fire spread and smoke movement. To obtain the variation of occurrence probability with time, Markov chain is combined with a time-dependent event tree for stochastic analysis on the occurrence probability of fire scenarios. To obtain consequences of every fire scenario, some uncertainties are considered in the risk analysis process. When calculating the onset time to untenable conditions, a range of fires are designed based on different fire growth rates, after which uncertainty of onset time to untenable conditions can be characterized by probability distribution. When calculating occupant evacuation time, occupant premovement time is considered as a probability distribution. Consequences of a fire scenario can be evaluated according to probability distribution of evacuation time and onset time of untenable conditions. Then, fire risk to life safety can be evaluated based on occurrence probability and consequences of every fire scenario. To express the risk assessment method in detail, a commercial building is presented as a case study. A discussion compares the assessment result of the case study with fire statistics.

  3. Fire Safety Training Handbook.

    ERIC Educational Resources Information Center

    Montgomery County Dept. of Fire and Rescue Services, Rockville, MD. Div. of Fire Prevention.

    Designed for a community fire education effort, particularly in which local volunteers present general information on fire safety to their fellow citizens, this workbook contains nine lessons. Included are an overview of the household fire problem; instruction in basic chemistry and physics of fire, flammable liquids, portable fire extinguishers,…

  4. School Fire Protection: Contents Count

    ERIC Educational Resources Information Center

    American School and University, 1976

    1976-01-01

    The heart of a fire protection system is the sprinkler system. National Fire Protection Association (NFPA) statistics show that automatic sprinklers dramatically reduce fire damage and loss of life. (Author)

  5. Fire Protection for Buildings

    ERIC Educational Resources Information Center

    Edmunds, Jane

    1972-01-01

    Reviews attack on fire safety in high rise buildings made by a group of experts representing the iron and steel industry at a recent conference. According to one expert, fire problems are people oriented, which calls for emphasis on fire prevention rather than reliance on fire suppression and for fire pretection to be built into a structure.…

  6. Firefighters United for Safety, Ethics, and Ecology (FUSEE): Torchbearers for a new fire management paradigm

    Treesearch

    Timothy Ingalsbee; Joseph Fox; Patrick Withen

    2007-01-01

    Firefighters United for Safety, Ethics, and Ecology (FUSEE) is a nonprofit organization promoting safe, ethical, ecological wildland fire management. FUSEE believes firefighter and community safety are ultimately interdependent with ethical public service, wildlands protection, and ecological restoration of fire-adapted ecosystems. Our members include current, former,...

  7. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  8. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  9. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Fire safety. 238.103 Section 238.103... § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a... section at the time it was tested. (c) Fire safety analysis for procuring new passenger cars and...

  10. Critical safety assurance factors for manned spacecraft - A fire safety perspective

    NASA Technical Reports Server (NTRS)

    Rodney, George A.

    1990-01-01

    Safety assurance factors for manned spacecraft are discussed with a focus on the Space Station Freedom. A hazard scenario is provided to demonstrate a process commonly used by safety engineers and other analysts to identify onboard safety risks. Fire strategies are described, including a review of fire extinguishing agents being considered for the Space Station. Lessons learned about fire safety technology in other areas are also noted. NASA and industry research on fire safety applications is discussed. NASA's approach to ensuring safety for manned spacecraft is addressed in the context of its multidiscipline program.

  11. Fire safety concerns in space operations

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1987-01-01

    This paper reviews the state-of-the-art in fire control techniques and identifies important issues for continuing research, technology, and standards. For the future permanent orbiting facility, the space station, fire prevention and control calls for not only more stringent fire safety due to the long-term and complex missions, but also for simplified and flexible safety rules to accommodate the variety of users. Future research must address a better understanding of the microgravity space environment as it influences fire propagation and extinction and the application of the technology of fire detection, extinguishment, and material assessment. Spacecraft fire safety should also consider the adaptation of methods and concepts derived from aircraft and undersea experience.

  12. 49 CFR 238.103 - Fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Fire safety. 238.103 Section 238.103..., DEPARTMENT OF TRANSPORTATION PASSENGER EQUIPMENT SAFETY STANDARDS Safety Planning and General Requirements § 238.103 Fire safety. (a) Materials. (1) Materials used in constructing a passenger car or a cab of a...

  13. Surgical fires: a patient safety perspective.

    PubMed

    2006-02-01

    A surgical fire is a fire that occurs on or in a surgical patient. Such fires are rare--they occur in only an extremely small percentage of surgical cases. Nevertheless, the actual number of incidents that occur each year may surprise many healthcare professionals. ECRI estimates that 50 to 100 or more surgical fires occur each year in the United States alone. And such fires can have devastating consequences, not only for the patient, but also for the surgical staff and for the healthcare facility. Fortunately, through awareness of the hazards-and with emphasis placed on following safe practices-virtually all surgical fires can be prevented. Thus, it's important that surgical fire safety be incorporated into formal patient safety initiatives. In this article, we describe a few surgical fire patient safety initiatives that have been instituted in recent years. In addition, we describe in detail the causes of surgical fires and the preventive measures that are available for healthcare personnel to follow. In addition, we review how staff should respond in the event of a surgical fire.

  14. 76 FR 10246 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... regulations and update the standards for VA approval of such facilities, including standards for fire safety... to ``RIN 2900-AN57--Updating Fire Safety [[Page 10247

  15. GLOVEBOX WINDOWS, FIRE PROTECTION AND VOICES FROM THE PAST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Till, W

    2009-04-15

    'Study the past--what is past is prologue'. These words appear as the motto on a pair of statues at the National Archives Building in Washington DC. They are also the opening sentence in the preface of a document written in August of 1956 entitled 'A Summary of Accidents and Incidents Involving Radiation in Atomic Energy Activities--June 1945 thru December 1955'. This document, one of several written by D.F. Hayes of the Safety and Fire Protection Branch, Division of Organization and Personnel, U.S. Atomic Energy Commission in Washington DC, and many others are often forgotten even though they contain valuable gloveboxmore » fire protection lessons for us today.« less

  16. Factors Controlling Vegetation Fires in Protected and Non-Protected Areas of Myanmar

    PubMed Central

    Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O.

    2015-01-01

    Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar. PMID:25909632

  17. Factors controlling vegetation fires in protected and non-protected areas of myanmar.

    PubMed

    Biswas, Sumalika; Vadrevu, Krishna Prasad; Lwin, Zin Mar; Lasko, Kristofer; Justice, Christopher O

    2015-01-01

    Fire is an important disturbance agent in Myanmar impacting several ecosystems. In this study, we quantify the factors impacting vegetation fires in protected and non-protected areas of Myanmar. Satellite datasets in conjunction with biophysical and anthropogenic factors were used in a spatial framework to map the causative factors of fires. Specifically, we used the frequency ratio method to assess the contribution of each causative factor to overall fire susceptibility at a 1km scale. Results suggested the mean fire density in non-protected areas was two times higher than the protected areas. Fire-land cover partition analysis suggested dominant fire occurrences in the savannas (protected areas) and woody savannas (non-protected areas). The five major fire causative factors in protected areas in descending order include population density, land cover, tree cover percent, travel time from nearest city and temperature. In contrast, the causative factors in non-protected areas were population density, tree cover percent, travel time from nearest city, temperature and elevation. The fire susceptibility analysis showed distinct spatial patterns with central Myanmar as a hot spot of vegetation fires. Results from propensity score matching suggested that forests within protected areas have 11% less fires than non-protected areas. Overall, our results identify important causative factors of fire useful to address broad scale fire risk concerns at a landscape scale in Myanmar.

  18. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  19. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  20. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  1. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  2. 14 CFR 23.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 23.859... Construction Fire Protection § 23.859 Combustion heater fire protection. (a) Combustion heater fire regions. The following combustion heater fire regions must be protected from fire in accordance with the...

  3. 46 CFR 176.810 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 176.810 Section 176.810 Shipping COAST...) INSPECTION AND CERTIFICATION Material Inspections § 176.810 Fire protection. (a) At each initial and... and have the vessel ready for inspection of its fire protection equipment, including the following: (1...

  4. Fire Protection for Rural Communities.

    ERIC Educational Resources Information Center

    Hagevig, William A.

    Fire protection in rural Alaskan communities depends on individual home fire prevention and protection rather than on the services offered by a centralized fire department. Even when help is summoned to extinguish a blaze, aid does not come in the form of a cadre of highly trained firefighters; it comes instead from whomever happens to be in the…

  5. Caught in a tightening fire safety net.

    PubMed

    Baillie, Jonathan

    2008-06-01

    How the Regulatory Reform (Fire Safety) Order 2005 has shifted responsibility for hospital fire safety from local fire authorities to so-called "responsible persons", and the implications for senior management/board-level personnel, as well as for hospital fire officers, fire wardens and department managers charged with implementation, was expertly examined by a leading expert in fire law at May's National Association of Healthcare Fire Officers (NAHFO) 2008 conference in Nottingham. Jonathan Baillie reports.

  6. 75 FR 17641 - Updating Fire Safety Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Parts 17 and 59 RIN 2900-AN57 Updating Fire Safety Standards... for VA approval of such facilities, including standards for fire safety and heating and cooling... submitted in response to ``RIN 2900-AN57--Updating Fire Safety Standards.'' Copies of comments received will...

  7. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  8. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  9. 29 CFR 1915.502 - Fire safety plan.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Fire safety plan. 1915.502 Section 1915.502 Labor... Employment § 1915.502 Fire safety plan. (a) Employer responsibilities. The employer must develop and implement a written fire safety plan that covers all the actions that employers and employees must take to...

  10. 14 CFR 33.17 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection. 33.17 Section 33.17... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.17 Fire protection. (a) The design and... fire during normal operation and failure conditions, and must minimize the effect of such a fire. In...

  11. Fire Protection Jacket

    NASA Technical Reports Server (NTRS)

    1991-01-01

    NERAC, Inc., Tolland, CT, aided Paul Monroe Engineering, Orange, CA, in the development of their PC1200 Series Fire Protection Jacket that protects the oil conduit system on an offshore drilling platform from the intense hydrocarbon fires that cause buckling and could cause structural failure of the platform. The flame-proof jacketing, which can withstand temperatures of 2000 degrees Fahrenheit for four hours or more, was developed from a combination of ceramic cloth (similar to the ceramic in Space Shuttle tiles), and laminates used in space suits.

  12. Campus Fire Safety Today.

    ERIC Educational Resources Information Center

    Thompson, Mike

    2001-01-01

    Reviews information on recent college and university dormitory fire fatalities, and highlights five examples of building features reported to be major contributing factors in residence-hall fires. Explains how public awareness and expectations are affecting school dormitory safety. (GR)

  13. Fire safety: A case study of technology transfer

    NASA Technical Reports Server (NTRS)

    Heins, C. F.

    1975-01-01

    Two basic ways in which NASA-generated technology is being used by the fire safety community are described. First, improved products and systems that embody NASA technical advances are entering the marketplace. Second, NASA test data and technical information related to fire safety are being used by persons concerned with reducing the hazards of fire through improved design information and standards. The development of commercial fire safety products and systems typically requires adaptation and integration of aerospace technologies that may not have been originated for NASA fire safety applications.

  14. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  15. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  16. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  17. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... fire. Fire safety system: Any mechanism or system related to the detection of a fire, the warning resulting from a fire, or the control of a fire. This may include sprinkler systems or other fire extinguishing systems, fire detection devices, stand-alone smoke alarms, devices that alert one to the presence...

  18. Burns and Fire Safety

    MedlinePlus

    Number of Deaths Death Rate Burns and Fire Safety Fact Sheet (2015) Fatalities • 334 children ages 19 and under died from fires or burns ... burns were ages 4 and under. 1 The death rate for children this age (0.73 per 100, ...

  19. Fire safety design of a mobile quarantine facility

    NASA Technical Reports Server (NTRS)

    Bass, R. S.; Hirasaki, J. K.

    1971-01-01

    During the design phase of the Mobile Quarantine Facility (MQF), a primary consideration was fire safety. Therefore, appropriate criteria and ground rules were used in the design and construction of the facility. The fire codes and fire-requirement listings that are used by commerical airlines were supplied to the Manned Spacecraft Center (MSC) by the Federal Aviation Agency (FAA). After these codes were reviewed, a basic ground rule was adopted that flame protection for all combustible materials should be at least equivalent to or better than the standards for commercial aircraft. Because the MQF was designed to operate with an interior atmosphere of air rather than with an oxygen-enriched atmosphere such as that of the Apollo spacecraft cabin, the requirements for MQF material were not as stringent as those for the spacecraft.

  20. Fire Protection Materials

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Avco has drawn upon its heat shield experience to develop a number of widely-accepted commercial fire protection materials. Originating from NASA's space shuttle thermal protection system, one such material is Chartek 59 fireproofing, an intumescent epoxy coating specifically designed for outdoor use by industrial facilities dealing with highly flammable products such as oil refineries and chemical plants. The coating is applied usually by spray gun to exterior structural steel conduits, pipes and valves, offshore platforms and liquefied petroleum gas tanks. Fireproofing provides two types of protection: ablation or dissipation of heat by burn-off and "intumescence" or swelling; the coating swells to about five times its original size, forming a protective blanket of char which retards transfer of heat to the metal structure preventing loss of structural strength and possible collapse which would compound the fire fighting problem.

  1. Fire in the Shop!

    ERIC Educational Resources Information Center

    Campbell, Clifton P.; Buchanan, Joseph P.

    1977-01-01

    Fire emergency preparedness measures to take to prevent school fires and to protect against injury and minimize damage when fire does occur are presented. Includes fire safety practices, extinguishers for different classes of fires and their use, and the need for fire safety training in schools. (MF)

  2. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... protective devices. (4) Means available for controlling or extinguishing a fire, such as stopping flow of...

  3. Large-Scale Spacecraft Fire Safety Tests

    NASA Technical Reports Server (NTRS)

    Urban, David; Ruff, Gary A.; Ferkul, Paul V.; Olson, Sandra; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Rouvreau, Sebastien; Minster, Olivier; hide

    2014-01-01

    An international collaborative program is underway to address open issues in spacecraft fire safety. Because of limited access to long-term low-gravity conditions and the small volume generally allotted for these experiments, there have been relatively few experiments that directly study spacecraft fire safety under low-gravity conditions. Furthermore, none of these experiments have studied sample sizes and environment conditions typical of those expected in a spacecraft fire. The major constraint has been the size of the sample, with prior experiments limited to samples of the order of 10 cm in length and width or smaller. This lack of experimental data forces spacecraft designers to base their designs and safety precautions on 1-g understanding of flame spread, fire detection, and suppression. However, low-gravity combustion research has demonstrated substantial differences in flame behavior in low-gravity. This, combined with the differences caused by the confined spacecraft environment, necessitates practical scale spacecraft fire safety research to mitigate risks for future space missions. To address this issue, a large-scale spacecraft fire experiment is under development by NASA and an international team of investigators. This poster presents the objectives, status, and concept of this collaborative international project (Saffire). The project plan is to conduct fire safety experiments on three sequential flights of an unmanned ISS re-supply spacecraft (the Orbital Cygnus vehicle) after they have completed their delivery of cargo to the ISS and have begun their return journeys to earth. On two flights (Saffire-1 and Saffire-3), the experiment will consist of a flame spread test involving a meter-scale sample ignited in the pressurized volume of the spacecraft and allowed to burn to completion while measurements are made. On one of the flights (Saffire-2), 9 smaller (5 x 30 cm) samples will be tested to evaluate NASAs material flammability screening tests

  4. Where's the Fire?

    ERIC Educational Resources Information Center

    Needham, Dorothy

    1977-01-01

    National Fire Protection Week is a perfect time for launching a fire safety learning center. The activities described here are intended to help children recognize fire hazards in their homes, play areas and public buildings; learn how to act intelligently in fire emergencies; be able to share their knowledge of fire safety with others and…

  5. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  6. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Fire safety. 62.35-15 Section 62.35-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump...

  7. 46 CFR 194.20-7 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 194.20-7 Section 194.20-7 Shipping... Fire protection. (a) Each chemical storeroom shall be protected by a fixed automatic carbon dioxide... fire extinguishers are required in accordance with Table 193.50-10(a) of this subchapter. ...

  8. 10 CFR 36.27 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Fire protection. 36.27 Section 36.27 Energy NUCLEAR... Requirements for Irradiators § 36.27 Fire protection. (a) The radiation room at a panoramic irradiator must... become fully shielded if a fire is detected. (b) The radiation room at a panoramic irradiator must be...

  9. Fire in the OR--developing a fire safety plan.

    PubMed

    McCarthy, Patricia M; Gaucher, Kenneth A

    2004-03-01

    Approximately 100 operating room fire occur each year in the United States. Although rare, fire in a perioperative setting can be disastrous for both patients and staff members. It is crucial that all perioperative departments have a well thought out and previously rehearsed fire plan in place. Multidisciplinary planning and implementation of regularly scheduled and scripted fire drills are essential to prevent adverse outcomes. Fire drills ensure that all staff members are familiar with the use and location of fire pull stations, fire extinguishers, and fire blankets. Fire drills also prepare staff members to evacuate the OR area if necessary. This article provides the information and framework necessary to develop and implement comprehensive OR fire safety plans that could make the difference between life and death in a fire emergency.

  10. Large Scale Experiments on Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Urban, David L.; Ruff, Gary A.; Minster, Olivier; Toth, Balazs; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Cowlard, Adam J.; Legros, Guillaume; Eigenbrod, Christian; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant know how about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal-gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being

  11. Large Scale Experiments on Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Urban, David; Ruff, Gary A.; Minster, Olivier; Fernandez-Pello, A. Carlos; Tien, James S.; Torero, Jose L.; Legros, Guillaume; Eigenbrod, Christian; Smirnov, Nickolay; Fujita, Osamu; hide

    2012-01-01

    Full scale fire testing complemented by computer modelling has provided significant knowhow about the risk, prevention and suppression of fire in terrestrial systems (cars, ships, planes, buildings, mines, and tunnels). In comparison, no such testing has been carried out for manned spacecraft due to the complexity, cost and risk associated with operating a long duration fire safety experiment of a relevant size in microgravity. Therefore, there is currently a gap in knowledge of fire behaviour in spacecraft. The entire body of low-gravity fire research has either been conducted in short duration ground-based microgravity facilities or has been limited to very small fuel samples. Still, the work conducted to date has shown that fire behaviour in low-gravity is very different from that in normal gravity, with differences observed for flammability limits, ignition delay, flame spread behaviour, flame colour and flame structure. As a result, the prediction of the behaviour of fires in reduced gravity is at present not validated. To address this gap in knowledge, a collaborative international project, Spacecraft Fire Safety, has been established with its cornerstone being the development of an experiment (Fire Safety 1) to be conducted on an ISS resupply vehicle, such as the Automated Transfer Vehicle (ATV) or Orbital Cygnus after it leaves the ISS and before it enters the atmosphere. A computer modelling effort will complement the experimental effort. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. This will facilitate the possibility of examining fire behaviour on a scale that is relevant to spacecraft fire safety and will provide unique data for fire model validation. This unprecedented opportunity will expand the understanding of the fundamentals of fire behaviour in spacecraft. The experiment is being

  12. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  13. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a... recommended that all new development be guided by standards of the NFPA Codes for fire and life safety and...

  14. Charged Up for Fire Safety. Fifth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fifth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fifth grade students, its objectives include: (1) exploring heating equipment safety, (2) analyzing the impact of fire on the outdoor environment and methods to reduce that impact, (3) developing…

  15. 34 CFR 668.49 - Institutional fire safety policies and fire statistics.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 3 2010-07-01 2010-07-01 false Institutional fire safety policies and fire statistics... fire statistics. (a) Additional definitions that apply to this section. Cause of fire: The factor or... statistics described in paragraph (c) of this section. (2) A description of each on-campus student housing...

  16. Fire protection for a Martian colony

    NASA Astrophysics Data System (ADS)

    Beattie, Robert M., Jr.

    The fire prevention failures that occurred in Apollo 1 and Challenger accidents are reviewed and used to discuss fire protection measures that should be taken in a Martian colony. Fire detection systems, classes of fire, and suppression agents are described. The organization of fire fighting personnel appropriate for Mars is addressed.

  17. Teach Children Fire Will Burn.

    ERIC Educational Resources Information Center

    Children's Bureau (DHEW), Washington, DC.

    This handbook, addressed to parents and others responsible for the safety of children, presents information on fire hazards, prevention and protection. Emphasizing an early start to fire safety training, it outlines the basic facts of fire safety education, listing the most frequent causes of fire and suggesting the organization of a Family Fire…

  18. Bridging the divide between fire safety research and fighting fire safely: How do we convey research innovation to contribute more effectively to wildland firefighter safety?

    Treesearch

    Theodore Ted Adams; Bret W. Butler; Sara Brown; Vita Wright; Anne Black

    2017-01-01

    Creating a safe workplace for wildland firefighters has long been at the centre of discussion for researchers and practitioners. The goal of wildland fire safety research has been to protect operational firefighters, yet its contributions often fall short of potential because much is getting lost in the translation of peer-reviewed results to potential and intended...

  19. Science and technology issues in spacecraft fire safety

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Sacksteder, Kurt R.

    1987-01-01

    The space station, a permanently-inhabited orbiting laboratory, places new demands on spacecraft fire safety. Long-duration missions may call for more-constrained fire controls, but the accessibility of the space station to a variety of users may call for less-restrictive measures. This paper discusses fire safety issues through a review of the state of the art and a presentation of key findings from a recent NASA Lewis Research Center Workshop. The subjects covered are the fundamental science of low-gravity combustion and the technology advances in fire detection, extinguishment, materials assessment, and atmosphere selection. Key concerns are for the adoption of a fire-safe atmosphere and the substitution for the effective but toxic extinguishant, halon 1301. The fire safety studies and reviews provide several recommendations for further action. One is the expanded research in combustion, sensors, and materials in the low-gravity environment of space. Another is the development of generalized fire-safety standards for spacecraft through cooperative endeavors with aerospace and outside Government and industry sources.

  20. Help Children--and Families--Learn Basic Fire Safety.

    ERIC Educational Resources Information Center

    Texas Child Care, 2001

    2001-01-01

    Presents tips to help early childhood teachers and caregivers teach young children fire safety. Provides checklist for preventing fires in the kitchen, classrooms, and storage areas. Offers suggestions for classroom learning activities and for educating families about fire safety. Includes annotated bibliography of children's books dealing with…

  1. Revised fire safety system cuts emergency response time.

    PubMed

    Keir, D C

    1979-03-01

    As Margaret R. Pardee Memorial Hospital, Hendersonville, NC. expanded, fire safety plans had to be reevaluated. With each new addition, fire safety responsibilities for hospital personnel multiplied and overlapped. Confusion resulted, and a revised, simplified, and coordinated fire safety system was devised. Seventeen false alarms within one year, caused by a faulty sprinkler system, gave hospital personnel ample opportunity to test the system and iron out unexpected problems.

  2. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2013-10-01 2013-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  3. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2011-10-01 2011-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  4. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2012-10-01 2012-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  5. 49 CFR 193.2717 - Training: fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... under § 193.2801. (b) A written plan of continuing instruction, including plant fire drills, must be... 49 Transportation 3 2014-10-01 2014-10-01 false Training: fire protection. 193.2717 Section 193...: fire protection. (a) All personnel involved in maintenance and operations of an LNG plant, including...

  6. Preventing Fire Death and Injury, Conducting a Fire Drill in a Group Home [and] When You Need a Fire Safety Expert. National Fire Safety Certification System. Continuing Education Program. Volume 1, Numbers 1-3.

    ERIC Educational Resources Information Center

    Walker, Bonnie

    Three booklets provide fire safety information for staff of residential facilities serving people with developmental disabilities. Booklets focus on: (1) preventing fire death and injury, (2) conducting a fire drill in a group home, and (3) the role of fire safety experts. The first booklet stresses the elimination of the following dangers:…

  7. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  8. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  9. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  10. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  11. 14 CFR 25.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 25.859....859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... surrounds the combustion chamber. However, no fire extinguishment is required in cabin ventilating air...

  12. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  13. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  14. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  15. 14 CFR 23.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 23.863... Construction Fire Protection § 23.863 Flammable fluid fire protection. (a) In each area where flammable fluids... fluids, shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of...

  16. Demonstration of Spacecraft Fire Safety Technology

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2012-01-01

    During the Constellation Program, the development of spacecraft fire safety technologies were focused on the immediate questions related to the atmosphere of the habitable volume and implementation of fire detection, suppression, and postfire clean-up systems into the vehicle architectures. One of the difficulties encountered during the trade studies for these systems was the frequent lack of data regarding the performance of a technology, such as a water mist fire suppression system or an optically-based combustion product monitor. Even though a spacecraft fire safety technology development project was being funded, there was insufficient time and funding to address all the issues as they were identified. At the conclusion of the Constellation Program, these knowledge gaps formed the basis for a project proposed to the Advanced Exploration Systems (AES) Program. This project, subsequently funded by the AES Program and in operation since October 2011, has as its cornerstone the development of an experiment to be conducted on an ISS resupply vehicle, such as the European Space Agency (ESA) Automated Transfer Vehicle (ATV) or Orbital Science s Cygnus vehicle after it leaves the ISS and before it enters the atmosphere. The technology development efforts being conducted in this project include continued quantification of low- and partial-gravity maximum oxygen concentrations of spacecraft-relevant materials, development and verification of sensors for fire detection and post-fire monitoring, development of standards for sizing and selecting spacecraft fire suppression systems, and demonstration of post-fire cleanup strategies. The major technology development efforts are identified in this paper but its primary purpose is to describe the spacecraft fire safety demonstration being planned for the reentry vehicle.

  17. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  18. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  19. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  20. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  1. 14 CFR 23.1359 - Electrical system fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire protection. 23.1359... Electrical Systems and Equipment § 23.1359 Electrical system fire protection. (a) Each component of the electrical system must meet the applicable fire protection requirements of §§ 23.863 and 23.1182. (b...

  2. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  3. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  4. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  5. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  6. 30 CFR 75.1103-11 - Tests of fire hydrants and fire hose; record of tests.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Tests of fire hydrants and fire hose; record of tests. 75.1103-11 Section 75.1103-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1103-11 Tests of fire hydrants and...

  7. Reported fire safety and first-aid amenities in Airbnb venues in 16 American cities.

    PubMed

    Kennedy, Hudson R; Jones, Vanya C; Gielen, Andrea

    2018-05-07

    Airbnb helps hosts rent all or part of their home to guests as an alternative to traditional hospitality settings. Airbnb venues are not uniformly regulated across the USA. This study quantified the reported prevalence of fire safety and first-aid amenities in Airbnb venues in the USA. The sample includes 120 691 venues in 16 US cities. Proportions of host-reported smoke and carbon monoxide (CO) detectors, fire extinguishers and first-aid kits were calculated. The proportion of venues that reportedly contained amenities are as follows: smoke detectors 80% (n=96 087), CO detectors 57.5% (n=69 346), fire extinguishers 42% (n=50 884) and first-aid kits 36% (n=43 497). Among this sample of Airbnb venues, safety deficiencies were noted. While most venues had smoke alarms, approximately 1/2 had CO alarms and less than 1/2 reported having a fire extinguishers or first-aid kits. Local and state governments or Airbnb must implement regulations compliant with current National Fire Protection Association fire safety standards. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Risk-based Spacecraft Fire Safety Experiments

    NASA Technical Reports Server (NTRS)

    Apostolakis, G.; Catton, I.; Issacci, F.; Paulos, T.; Jones, S.; Paxton, K.; Paul, M.

    1992-01-01

    Viewgraphs on risk-based spacecraft fire safety experiments are presented. Spacecraft fire risk can never be reduced to a zero probability. Probabilistic risk assessment is a tool to reduce risk to an acceptable level.

  9. Halogenated flame retardants: do the fire safety benefits justify the risks?

    PubMed

    Shaw, Susan D; Blum, Arlene; Weber, Roland; Kannan, Kurunthachalam; Rich, David; Lucas, Donald; Koshland, Catherine P; Dobraca, Dina; Hanson, Sarah; Birnbaum, Linda S

    2010-01-01

    smoke detectors can prevent fires without the potential adverse effects of flame retardant chemicals. (6) Alternatives to organohalogen flame retardant chemicals include using less flammable materials, design changes, and safer chemicals. To date, before evaluating their health and environmental impacts, many flame retardant chemicals have been produced and used, resulting in high levels of human exposure. As a growing literature continues to find adverse impacts from such chemicals, a more systematic approach to their regulation is needed. Before implementing new flammability standards, decision-makers should evaluate the potential fire safety benefit versus the health and environmental impacts of the chemicals, materials, or technologies likely to be used to meet the standard. Reducing the use of toxic or untested flame retardant chemicals in consumer products can protect human and animal health and the global environment without compromising fire safety.

  10. Characteristics of sprinklers and water spray mists for fire safety

    NASA Astrophysics Data System (ADS)

    Jackman, Louise A.; Lavelle, Stephen P.; Nolan, P. F.

    1991-04-01

    In order to predict the type of sprinkler or spray head required for fire safety in buildings and transport systems (e.g. aircraft) it is necessary to model the interaction of water droplets with the thermally buoyant fire gases. Such modelling requires a detailed knowledge of the mean droplet size, the droplet size distribution, droplet velocity and trajectory. Many existing systems for the characterisation of droplets are indirect in that an optical property is measured and the results are subject to "black box" data processing. A direct method can be developed using a synchronised metal vapour laser and high speed cine camera with appropriate optics. Results on both sprinkler and spray mist will be presented and a basis for the choice of active fire protection systems will be outlined.

  11. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  12. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  13. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 7 2011-07-01 2011-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  14. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities. The employer must ensure all fixed and portable fire protection systems needed to meet an OSHA...

  15. Fire Safety in Nursing Facilities: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    Fewer people die in nursing facility fires than in fires occurring in other places where older people live. Fire remains, however, a significant threat in nursing facilities. This book is centered around six "modules" that present a fire safety training program for managers and staff in nursing homes. These modules present the following…

  16. Fire Safety for Retired Adults: Participant's Coursebook.

    ERIC Educational Resources Information Center

    Walker (Bonnie) and Associates, Inc., Crofton, MD.

    The risk of dying from fire increases substantially among older adults. This document contains a collection of fire safety information for elderly people. Information includes procedures to follow in case of fire and early warning technologies such as smoke alarms. The booklet describes potential sources of fires (smoking, home heating, kitchens,…

  17. Fire Safety. Managing School Facilities, Guide 6.

    ERIC Educational Resources Information Center

    Department for Education and Employment, London (England). Architects and Building Branch.

    This booklet discusses how United Kingdom schools can manage fire safety and minimize the risk of fire. The guide examines what legislation school buildings must comply with and covers the major risks. It also describes training and evacuation procedures and provides guidance on fire precautions, alarm systems, fire fighting equipment, and escape…

  18. Updating fire safety standards. Final rule; affirmation.

    PubMed

    2011-11-16

    This document affirms as final, without changes, a provision included in a final rule with request for comments that amended the Department of Veterans Affairs (VA) regulations concerning community residential care facilities, contract facilities for certain outpatient and residential services, and State home facilities. That provision established a five-year period within which all covered buildings with nursing home facilities existing as of June 25, 2001, must conform to the automatic sprinkler requirement of the 2009 edition of the National Fire Protection Association (NFPA) 101. This rule helps ensure the safety of veterans in the affected facilities.

  19. Remote monitoring of a Fire Protection System

    NASA Astrophysics Data System (ADS)

    Bauman, Steven; Vermeulen, Tom; Roberts, Larry; Matsushige, Grant; Gajadhar, Sarah; Taroma, Ralph; Elizares, Casey; Arruda, Tyson; Potter, Sharon; Hoffman, James

    2011-03-01

    Some years ago CFHT proposed developing a Remote Observing Environment aimed at producing Science Observations at their Observatory Facility on Mauna Kea from their Headquarters facility in Waimea, HI. This Remote Observing Project commonly referred to as OAP (Observatory Automation Project) was completed at the end of January 2011 and has been providing the majority of Science Data since. My poster will discuss the upgrades to the existing fire alarm protection system. With no one at the summit during nightly operations, the observatory facility required automated monitoring of the facility for safety to personnel and equipment in the case of a fire. An addressable analog fire panel was installed which utilizes digital communication protocol (DCP), intelligent communication with other devices, and an RS-232 interface which provides feedback and real-time monitoring of the system. Using the interface capabilities of the panel, it provides notifications when heat detectors, smoke sensors, manual pull stations, or the main observatory computer room fire suppression system has been activated. The notifications are sent out as alerts to staff in the form of test massages and emails and the observing control GUI interface alerts the remote telescope operator with a map showing the location of the fire occurrence and type of device that has been triggered. And all of this was accomplished without the need for an outside vendor to monitor the system and facilitate warnings or notifications regarding the system.

  20. Fire Safety Trianing in Health Care Institutions.

    ERIC Educational Resources Information Center

    American Hospital Association, Chicago, IL.

    The manual details the procedures to be followed in developing and implementing a fire safety plan. The three main steps are first, to organize; second, to set up a procedure and put it in writing; and third, to train and drill employees and staff. Step 1 involves organizing a safety committee, appointing a fire marshall, and seeking help from…

  1. Reserves Protect against Deforestation Fires in the Amazon

    PubMed Central

    Adeney, J. Marion; Christensen, Norman L.; Pimm, Stuart L.

    2009-01-01

    Background Reserves are the principal means to conserve forests and biodiversity, but the question of whether reserves work is still debated. In the Amazon, fires are closely linked to deforestation, and thus can be used as a proxy for reserve effectiveness in protecting forest cover. We ask whether reserves in the Brazilian Amazon provide effective protection against deforestation and consequently fires, whether that protection is because of their location or their legal status, and whether some reserve types are more effective than others. Methodology/Principal Findings Previous work has shown that most Amazonian fires occur close to roads and are more frequent in El Niño years. We quantified these relationships for reserves and unprotected areas by examining satellite-detected hot pixels regressed against road distance across the entire Brazilian Amazon and for a decade with 2 El Niño-related droughts. Deforestation fires, as measured by hot pixels, declined exponentially with increasing distance from roads in all areas. Fewer deforestation fires occurred within protected areas than outside and the difference between protected and unprotected areas was greatest near roads. Thus, reserves were especially effective at preventing these fires where they are known to be most likely to burn; but they did not provide absolute protection. Even within reserves, at a given distance from roads, there were more deforestation fires in regions with high human impact than in those with low impact. The effect of El Niño on deforestation fires was greatest outside of reserves and near roads. Indigenous reserves, limited-use reserves, and fully protected reserves all had fewer fires than outside areas and did not appear to differ in their effectiveness. Conclusions/Significance Taking time, regional factors, and climate into account, our results show that reserves are an effective tool for curbing destructive burning in the Amazon. PMID:19352423

  2. Fire Hazard Assessment in Supporting Fire Protection System Design of a Chemical Process Facility

    DTIC Science & Technology

    1996-08-01

    CSDP/Studies/FireHaz –i– 3/28/97 FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY Ali Pezeshk...Joseph Chang, Dwight Hunt, and Peter Jahn Parsons Infrastructure & Technology Group, Inc. Pasadena, California 91124 ABSTRACT Because fires in a chemical ...Assessment in Supporting Fire Protection System Design of a Chemical Process Facility 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  3. Progress Report for Student Research: Fire Safety Skills for Mentally Retarded Children.

    ERIC Educational Resources Information Center

    Hayden, Mary F.; Lefcowitz, M. Jack

    A comprehensive fire safety skills program was evaluated with 32 moderately to mildly retarded adolescents. The program used a fire safety program manual and lessons in basic preventive fire skills, fire safety procedures, and fire escape skills. Across-group comparisons indicated differences in performance between males and females. Fire safety…

  4. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  5. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  6. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  7. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  8. 14 CFR 29.859 - Combustion heater fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Combustion heater fire protection. 29.859... § 29.859 Combustion heater fire protection. (a) Combustion heater fire zones. The following combustion... any ventilating air passage that— (i) Surrounds the combustion chamber; and (ii) Would not contain...

  9. The Safety Analysis of Shipborne Ammunition in Fire Environment

    NASA Astrophysics Data System (ADS)

    Ren, Junpeng; Wang, Xudong; Yue, Pengfei

    2017-12-01

    The safety of Ammunition has always been the focus of national military science and technology issues. And fire is one of the major safety threats to the ship’s ammunition storage environment, In this paper, Mk-82 shipborne aviation bomb has been taken as the study object, simulated the whole process of fire by using the FDS (Fire Detection System) software. According to the simulation results of FDS, ANSYS software was used to simulate the temperature field of Mk-82 carrier-based aviation bomb under fire environment, and the safety of aviation bomb in fire environment was analyzed. The result shows that the aviation bombs under the fire environment can occur the combustion or explosion after 70s constant cook-off, and it was a huge threat to the ship security.

  10. Fires and Food Safety

    MedlinePlus

    ... Administrative Forms Standard Forms Skip Navigation Z7_0Q0619C0JGR010IFST1G5B10H1 Web Content Viewer (JSR 286) Actions ${title} Loading... / Topics / ... Food Safety / Fires and Food Safety Z7_0Q0619C0JGR010IFST1G5B10H3 Web Content Viewer (JSR 286) Actions ${title} Loading... Z7_ ...

  11. Rx fire laws: tools to protect fire: the `ecological imperative?

    Treesearch

    Dale Wade; Steven Miller; Johnny Stowe; James Brenner

    2006-01-01

    The South is the birthplace of statutes and ordinances that both advocate and protect the cultural heritage of woods burning, which has been practiced in this region uninterrupted for more than 10,000 years. We present a brief overview of fire use in the South and discuss why most southern states recognized early on that periodic fire was necessary to sustain fire...

  12. Fire Protection. Honeywell Planning Guide.

    ERIC Educational Resources Information Center

    Honeywell, Inc., Minneapolis, Minn.

    A general discussion of fire alarms and protection is provided by a manufacturer of automated monitoring and control systems. Background information describes old and new fire alarm systems, comparing system components, wage savings, and cost analysis. Different kinds of automatic systems are listed, including--(1) local system, (2) auxiliary…

  13. Fighting Fire with Fire.

    ERIC Educational Resources Information Center

    Spoor, Dana L.

    1996-01-01

    School districts are integrating security and life-safety systems into school buildings to protect students and property. This proactive approach includes sprinkler systems, fire alarms, and security systems that monitor door movement. Some school districts that are incorporating the latest life-safety technology are in Missouri, Ohio, California,…

  14. 14 CFR 25.854 - Lavatory fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Fire Protection § 25.854 Lavatory fire protection. For airplanes with a passenger capacity of 20 or more: (a) Each lavatory must be... disposal receptacle for towels, paper, or waste, located within the lavatory. The extinguisher must be...

  15. 36 CFR § 910.37 - Fire and life safety.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for fire and life safety and that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Fire and life safety. § 910... PENNSYLVANIA AVENUE DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and...

  16. Minutes of the Rapid Action Fire Protection System Seminar Held at Rock Island, Illinois on 23-24 October 1984

    DTIC Science & Technology

    1984-10-01

    A\\5AI5?? 93<» MINUTES OF THE RAPID ACTION FIRE PROTECTION SYSTEM SEMINAR AMCCOM SAFETY OFFICE 23-24 OCTOBER 1984 PREFACE This seminar was...held as a medium by which there could be a free exchange of information on rapid action fire protection systems used in munition production operations...The objectives of the seminar were- - Discuss system operating principles & system components. - Exchange latest technical data, developments, and

  17. Children's Knowledge of Fire Safety: A Report for the New Zealand Fire Service.

    ERIC Educational Resources Information Center

    Constable, Cheryl; Renwick, Margery

    The study reported in this document was conducted to measure the impact of the New Zealand Fire Service's new fire safety program on elementary school students. Firefighters in each fire station and voluntary fire brigade in New Zealand were responsible for arranging a visit to every elementary school within their area to present a learning…

  18. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a...

  19. 36 CFR 910.37 - Fire and life safety.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... that all buildings be equipped with an approved sprinkler system. ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Fire and life safety. 910.37... DEVELOPMENT AREA Standards Uniformly Applicable to the Development Area § 910.37 Fire and life safety. As a...

  20. Research in fire prevention.

    PubMed

    Pearce, N

    1985-10-01

    This paper describes in broad terms, the fire testing programme we carried out on whole bed assemblies in 1984. It should be clear that the tests were carried out in a thoroughly rigorous scientific manner. As always there is more to be done. The immediate task of finding the so called 'safe' bed assembly is proceeding with the search this year for safer pillows. Softer barrier foams are now being produced and it may be that the NHS could use full depth foam mattresses rather than a barrier foam wrap. On the engineering side I have explained the false alarm problem, and I have reviewed some of the research we are doing to see that new technology is used to give us better systems in future. Life safety sprinkler systems give the possibility of truly active fire protection in patient areas. They will enhance fire safety but at the moment no trade-offs can be offered in other areas of fire protection--either active or passive. My final point is that although I have considered the Department's fire research by looking separately at specific projects, the fire safety of a hospital must always be considered as a total package. To be effective, individual components of fire safety must not be considered in isolation but as part of the overall fire safety system.

  1. Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-06-01

    corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating

  2. Spacecraft Fire Safety 1956 to 1999: An Annotated Bibliography

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Ruff, Gary A.

    2013-01-01

    Knowledge of fire safety in spacecraft has resulted from over 50 years of investigation and experience in space flight. Current practices and procedures for the operation of the Space Transportation System (STS) shuttle and the International Space Station (ISS) have been developed from this expertise, much of which has been documented in various reports. Extending manned space exploration from low Earth orbit to lunar or Martian habitats and beyond will require continued research in microgravity combustion and fire protection in low gravity. This descriptive bibliography has been produced to document and summarize significant work in the area of spacecraft fire safety that was published between 1956 and July 1999. Although some important work published in the late 1990s may be missing, these citations as well as work since 2000 can generally be found in Web-based resources that are easily accessed and searched. In addition to the citation, each reference includes a short description of the contents and conclusions of the article. The bibliography contains over 800 citations that are cross-referenced both by topic and the authors and editors. There is a DVD that accompanies this bibliography (available by request from the Center for Aerospace Information) containing the full-text articles of selected citations as well as an electronic version of this report that has these citations as active links to their corresponding full-text article.

  3. Current State of European Railway Fire Safety Research

    DOT National Transportation Integrated Search

    1985-06-01

    This report describes the recent fire safety research and practical fire experience of the major European railways. It includes a summary of the main causes and characteristics of railway vehicle fires, general approaches to the problem, and existing...

  4. Fire protection review revisit no. 2, Argonne National Laboratory, Argonne, Illinois

    NASA Astrophysics Data System (ADS)

    Dobson, P. H.; Earley, M. W.; Mattern, L. J.

    1985-05-01

    A fire protection survey was conducted at Argonne National Laboratory on April 1-5, 8-12, and April 29-May 2, 1985. The purpose was to review the facility fire protection program and to make recommendations or identify areas according to criteria established by the Department of Energy. There has been a substantial improvement in fire protection at this laboratory since the 1977 audit. Numerous areas which were previously provided with detection systems only have since been provided with automatic sprinkler protection. The following basic fire protection features are not properly controlled: (1) resealing wall and floor penetrations between fire areas after installation of services; (2) cutting and welding; and (3) housekeeping. The present Fire Department manpower level appears adequate to control a route fire. Their ability to adequately handle a high-challenge fire, or one involving injuries to personnel, or fire spread beyond the initial fire area is doubtful.

  5. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  6. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  7. 46 CFR 62.35-15 - Fire safety.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Requirements for Specific Types of Automated Vital Systems § 62.35-15 Fire safety. (a) All required fire pump remote control locations must include the controls necessary to charge the firemain and— (1) A firemain...

  8. Impact of a community based fire prevention intervention on fire safety knowledge and behavior in elementary school children

    PubMed Central

    Hwang, V; Duchossois, G P; Garcia‐Espana, J F; Durbin, D R

    2006-01-01

    The objective of this study was to determine the impact of a community based fire prevention intervention directed only to parents on the fire safety knowledge and behavior in elementary school children. This was a prospective, quasi‐randomized controlled study in which third and fourth grade students from two elementary schools in an urban, poor, minority community completed knowledge/behavior surveys at baseline and following completion of the intervention. The intervention group received an in‐home visit from fire department personnel who installed free lithium smoke detectors and provided a fire escape plan. After accounting for a small difference in baseline summary scores of knowledge and behavior between the control and intervention groups, this study found a modest improvement in fire safety behavior among children whose families received a fire prevention intervention reflecting a change in household fire safety practices. However, there was no significant change in fire safety knowledge. PMID:17018679

  9. Stochastic representation of fire behavior in a wildland fire protection planning model for California.

    Treesearch

    J. Keith Gilless; Jeremy S. Fried

    1998-01-01

    A fire behavior module was developed for the California Fire Economics Simulator version 2 (CFES2), a stochastic simulation model of initial attack on wildland fire used by the California Department of Forestry and Fire Protection. Fire rate of spread (ROS) and fire dispatch level (FDL) for simulated fires "occurring" on the same day are determined by making...

  10. Advanced spacecraft fire safety: Proposed projects and program plan

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.; Vedha-Nayagam, M.

    1989-01-01

    A detailed review identifies spacecraft fire safety issues and the efforts for their resolution, particularly for the threats posed by the increased on-orbit duration, size, and complexity of the Space Station Freedom. Suggestions provided by a survey of Wyle consultants and outside fire safety experts were combined into 30 research and engineering projects. The projects were then prioritized with respect to urgency to meet Freedom design goals, status of enabling technology, cost, and so on, to yield 14 highest priority projects, described in terms of background, work breakdown structure, and schedule. These highest priority projects can be grouped into the thematic areas of fire detection, fire extinguishment, risk assessment, toxicology and human effects, and ground based testing. Recommendations for overall program management stress the need for NASA Headquarters and field center coordination, with information exchange through spacecraft fire safety oversight committees.

  11. Acquisition of Fire Safety Knowledge and Skills With Virtual Reality Simulation.

    PubMed

    Rossler, Kelly L; Sankaranarayanan, Ganesh; Duvall, Adrianne

    2018-05-25

    Prelicensure nursing students seeking to enter perioperative nursing need preparatory fire safety knowledge and skills training to participate as a member of an operating room (OR) team. This pilot study examined the effectiveness of the Virtual Electrosurgery Skill Trainer (VEST) on OR fire safety skills among prelicensure nursing students. An experimental pretest-posttest design was used in this study. Twenty nursing students were randomized to a control or an intervention group. Knowledge and skills acquisition of OR fire safety were assessed. There were no statistically significant findings in knowledge for either group. Fisher exact test demonstrated significant relationships between the skills performance criteria of following emergency procedures for a fire and demonstrating PASS (pull-aim-squeeze-sweep) technique (P = .001). Academic and hospital educators may consider incorporating virtual reality simulation to teach fire safety education or reinforce general fire safety practices to nursing students and novice nurses.

  12. DEVELOPMENT OF ALTERNATIVE, NON-HALOGEN FIRE PROTECTION SYSTEM

    EPA Science Inventory

    With the phaseout of halon production, two alternative technologies - water misting and low-residue particulates - have come to the fire protection forefront. These technologies use water or dry chemicals in reduced quantities to provide acceptable fire protection. A review and a...

  13. Passive fire building protection system evaluation (case study: millennium ict centre)

    NASA Astrophysics Data System (ADS)

    Rahman, Vinky; Stephanie

    2018-03-01

    Passive fire protection system is a system that refers to the building design, both regarding of architecture and structure. This system usually consists of structural protection that protects the structure of the building and prevents the spread of fire and facilitate the evacuation process in case of fire. Millennium ICT Center is the largest electronic shopping center in Medan, Indonesia. As a public building that accommodates the crowd, this building needs a fire protection system by the standards. Therefore, the purpose of this study is to evaluate passive fire protection system of Millennium ICT Center building. The study was conducted to describe the facts of the building as well as direct observation to the research location. The collected data is then processed using the AHP (Analytical Hierarchy Process) method in its weighting process to obtain the reliability value of passive fire protection fire system. The results showed that there are some components of passive fire protection system in the building, but some are still unqualified. The first section in your paper

  14. Research Needs in Fire Safety for the Human Exploration and Utilization of Space: Proceedings and Research Plan

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2003-01-01

    The purpose of the workshop documented in this publication was to bring together personnel responsible for the design and operations of the International Space Station (ISS) and the fire protection research community to review the current knowledge in fire safety relative to spacecraft. From this review, research needs were identified that were then used to formulate a research plan with specific objectives. In this document, I have attempted to capture the very informative and lively discussions that occurred in the plenary sessions and the working groups. I hope that it will be useful to readers and serve as a significant step in assuring fire protection for the crews of current and future spacecraft.

  15. Fire and worker health and safety: an introduction to the special issue.

    PubMed

    Campbell, Richard; Levenstein, Charles

    2015-02-01

    One century ago, the landmark fire at the Triangle Shirtwaist Factory in New York City claimed the lives of 146 garment workers and helped spur the adoption of fire safety measures and laws targeting dangerous working conditions. Since that time, continuing advances have been made to address the threat of fire-in workplace fire safety practices and regulations, in training and safety requirements for firefighters and first responders, and in hazard communication laws that enhance disaster planning and response. Recent high profile events, including the West, Texas fertilizer plant explosion, derailments of fuel cargo trains, and garment factory fires in Bangladesh, have brought renewed attention to fire as a workplace health and safety issue and to the unevenness of safety standards and regulatory enforcement, in the United States as well as internationally. In this article, we provide an overview of fire as a workplace health and safety hazard and an introduction to the essays included in this special issue of New Solutions on fire and work. © 2015 SAGE Publications.

  16. Cost-benefit analysis of passive fire protections in road LPG transportation.

    PubMed

    Paltrinieri, Nicola; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio

    2012-02-01

    The cost-benefit evaluation of passive fire protection adoption in the road transport of liquefied petroleum gas (LPG) was investigated. In a previous study, mathematical simulations of real scale fire scenarios proved the effectiveness of passive fire protections in preventing the "fired" boiling liquid expanding vapor explosion (BLEVE), thus providing a significant risk reduction. In the present study the economical aspects of the adoption of fire protections are analyzed and an approach to cost-benefit analysis (CBA) is proposed. The CBA model is based on the comparison of the risk reduction due to fire protections (expressed in monetary terms by the value of a statistical life) and the cost of the application of fire protections to a fleet of tankers. Different types of fire protections were considered, as well as the possibility to apply protections to the entire fleet or only to a part of it. The application of the proposed model to a real-life case study is presented and discussed. Results demonstrate that the adoption of passive fire protections on road tankers, though not compulsory in Europe, can be economically feasible, thus representing a concrete measure to achieve control of the "major hazard accidents" cited by the European legislation. © 2011 Society for Risk Analysis.

  17. Happy 50th Birthday Smokey Bear! A Learning Kit about Forests and Fire Safety for Grades K-3.

    ERIC Educational Resources Information Center

    Hall, Meryl

    For over 50 years, the primary goal of Smokey Bear has been to introduce the forest fire prevention message to young children. This learning kit provides the K-3 teacher with activities and resources to help students learn about Smokey Bear and fire safety, about forests as habitats, and about what they can do to protect forests. Students are…

  18. 10 CFR 50.48 - Fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...

  19. 10 CFR 50.48 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... suppression systems; and (iii) The means to limit fire damage to structures, systems, or components important...) Standard 805, “Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating... pressurized-water reactors (PWRs) is not permitted. (iv) Uncertainty analysis. An uncertainty analysis...

  20. Combustion and fires in low gravity

    NASA Technical Reports Server (NTRS)

    Friedman, Robert

    1994-01-01

    Fire safety always receives priority attention in NASA mission designs and operations, with emphasis on fire prevention and material acceptance standards. Recently, interest in spacecraft fire-safety research and development has increased because improved understanding of the significant differences between low-gravity and normal-gravity combustion suggests that present fire-safety techniques may be inadequate or, at best, non-optimal; and the complex and permanent orbital operations in Space Station Freedom demand a higher level of safety standards and practices. This presentation outlines current practices and problems in fire prevention and detection for spacecraft, specifically the Space Station Freedom's fire protection. Also addressed are current practices and problems in fire extinguishment for spacecraft.

  1. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  2. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  3. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  4. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  5. 14 CFR 23.1451 - Fire protection for oxygen equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection for oxygen equipment. 23... Equipment Miscellaneous Equipment § 23.1451 Fire protection for oxygen equipment. Oxygen equipment and lines... in, or escape from, any designated fire zone. (c) Be installed so that escaping oxygen cannot come in...

  6. Applications of aerospace technology in industry, a technology transfer profile: Fire safety

    NASA Technical Reports Server (NTRS)

    Kottenstette, J. P.; Freeman, J. E.; Heins, C. R.; Hildred, W. M.; Johnson, F. D.; Staskin, E. R.

    1971-01-01

    The fire safety field is considered as being composed of three parts: an industry, a technology base, and a user base. An overview of the field is presented, including a perspective on the magnitude of the national fire safety problem. Selected NASA contributions to the technology of fire safety are considered. Communication mechanisms, particularly conferences and publications, used by NASA to alert the community to new developments in the fire safety field, are reviewed. Several examples of nonaerospace applications of NASA-generated fire safety technology are also presented. Issues associated with attempts to transfer this technology from the space program to other sectors of the American economy are outlined.

  7. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  8. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  9. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  10. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Electrical system fire and smoke protection... Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system must meet the applicable fire and smoke protection provisions of §§ 29.831 and 29.863. (b) Electrical...

  11. Safety, Health, and Fire Prevention Guide for Hospital Safety Managers

    DTIC Science & Technology

    1993-03-01

    Safety committee S 2-5 Oxygen quality assurance program 0 2-6 Safety and fire prevention library 0 2-7 Safety services to Dental Activities • 2-8...Chapter 2 Safety Management 2-1. Safety policy statement Health Services Command (HSC) Supplement (Suppl) 1 to Army Regulation (AR) 385-10 and the...Management. (b) The medical staff. (c) The nursing service . (d) Logistics. (e) Nutritional care. (f) Preventive medicine. * 2-3 USAEHA TG No. 152 March 1993 (g

  12. Contributions of microgravity test results to the design of spacecraft fire-safety systems

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Urban, David L.

    1993-01-01

    Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

  13. Contributions of Microgravity Test Results to the Design of Spacecraft Fire Safety Systems

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Urban, David L.

    1993-01-01

    Experiments conducted in spacecraft and drop towers show that thin-sheet materials have reduced flammability ranges and flame-spread rates under quiescent low-gravity environments (microgravity) as compared to normal gravity. Furthermore, low-gravity flames may be suppressed more easily by atmospheric dilution or decreasing atmospheric total pressure than their normal-gravity counterparts. The addition of a ventilating air flow to the low-gravity flame zone, however, can greatly enhance the flammability range and flame spread. These results, along with observations of flame and smoke characteristics useful for microgravity fire-detection 'signatures', promise to be of considerable value to spacecraft fire-safety designs. The paper summarizes the fire detection and suppression techniques proposed for the Space Station Freedom and discusses both the application of low-gravity combustion knowledge to improve fire protection and the critical needs for further research.

  14. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  15. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  16. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  17. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  18. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  19. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 29.863... § 29.863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might..., shutting down equipment, fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft...

  20. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  1. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  2. 14 CFR 27.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 27.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of rotorcraft components that are...

  3. 29 CFR 1915.507 - Land-side fire protection systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... specific recommendations in NFPA 14-2003 Standard for the Installation of Standpipe and Hose Systems... 29 Labor 7 2010-07-01 2010-07-01 false Land-side fire protection systems. 1915.507 Section 1915... Protection in Shipyard Employment § 1915.507 Land-side fire protection systems. (a) Employer responsibilities...

  4. 76 FR 40777 - Interim Enforcement Policy for Certain Fire Protection Issues

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-12

    ... Certain Fire Protection Issues AGENCY: Nuclear Regulatory Commission. ACTION: Policy statement; revision... Enforcement Policy on enforcement discretion for certain fire protection issues to extend the enforcement... policy affects licensees that are transitioning to use the National Fire Protection Association Standard...

  5. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2014-07-01 2014-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  6. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2011-07-01 2011-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  7. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2013-07-01 2013-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  8. 29 CFR 1926.150 - Fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... Modification of sprinkler systems to permit alterations or additional demolition should be expedited so that... each floor. (e) Fire alarm devices. (1) An alarm system, e.g., telephone system, siren, etc., shall be... 29 Labor 8 2012-07-01 2012-07-01 false Fire protection. 1926.150 Section 1926.150 Labor...

  9. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  10. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  11. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  12. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Flammable fluid fire protection. 25.863....863 Flammable fluid fire protection. (a) In each area where flammable fluids or vapors might escape by..., fireproof containment, or use of extinguishing agents. (5) Ability of airplane components that are critical...

  13. School Fire Safety Manual.

    ERIC Educational Resources Information Center

    Arkansas State Dept. of Education, Little Rock. General Education Div.

    This manual provides the background information necessary for the planning of school fire safety programs by local school officials, particularly in Arkansas. The manual first discusses the need for such programs and cites the Arkansas state law regarding them. Policies established by the Arkansas State Board of Education to implement the legal…

  14. CFES--California Fire Economics Simulator: A Computerized System for Wildland Fire Protection Planning

    Treesearch

    Jeremy S. Fried; J. Keith Gilless; Robert E. Martin

    1987-01-01

    The University of California's Department of Forestry and Resource Management, under contract with the California Department of Forestry and Fire Protection, has developed and released the first version of the California Fire Economics Simulator (CFES). The current release is adapted from the Initial Action Assessment component of the USFS's National Fire...

  15. An organizational process for promoting home fire safety in two community settings.

    PubMed

    Lehna, Carlee; Twyman, Stephanie; Fahey, Erin; Coty, Mary-Beth; Williams, Joe; Scrivener, Drane; Wishnia, Gracie; Myers, John

    2017-02-01

    The purpose of this study was to describe the home fire safety quality improvement model designed to aid organizations in achieving institutional program goals. The home fire safety model was developed from community-based participatory research (CBPR) applying training-the-trainer methods and is illustrated by an institutional case study. The model is applicable to other types of organizations to improve home fire safety in vulnerable populations. Utilizing the education model leaves trained employees with guided experience to build upon, adapt, and modify the home fire safety intervention to more effectively serve their clientele, promote safety, and meet organizational objectives. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  16. Motorcoach and school bus fire safety analysis.

    DOT National Transportation Integrated Search

    2016-11-01

    This report documents a motorcoach and school bus fire safety analysis performed by the John A. Volpe National Transportation Systems Center (Volpe) for the Federal Motor Carrier Safety Administration. This report aims to: 1) identify the causes, fre...

  17. Fire safety arrangement of inhabited pressurized compartments of manned spacecraft

    NASA Astrophysics Data System (ADS)

    Bolodian, Ivan; Melikhov, Anatoliy; Tanklevskiy, Leonid

    2017-06-01

    The article deals with innovative technical solutions that provide fire safety in inhabited pressurized compartments of manned spacecraft by means of a fireproof device of inhabited pressurized compartments via application of engineering means of fire prevention and fire spreading prevention by lowering fire load in an inhabited pressurized module up to the point when the maximum possible levels of fire factors in an inhabited pressurized compartment of a manned spacecraft are prevented. Represented technical solutions are used at the present time according to stated recommendations during provision of fire safety of equipment created by a number of Russian organizations for equipage of inhabited pressurized compartments of spacecraft of the Russian segment of International space station.

  18. 48 CFR 245.7311-2 - Safety, security, and fire regulations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Safety, security, and fire regulations. 245.7311-2 Section 245.7311-2 Federal Acquisition Regulations System DEFENSE ACQUISITION... Inventory 245.7311-2 Safety, security, and fire regulations. ...

  19. Spacecraft fire-safety experiments for space station: Technology development mission

    NASA Technical Reports Server (NTRS)

    Youngblood, Wallace W.

    1988-01-01

    Three concept designs for low-gravity, fire-safety related experiments are presented, as selected for the purpose of addressing key issues of enhancing safety and yet encouraging access to long-duration, manned spacecraft such as the NASA space station. The selected low-gravity experiments are the following: (1) an investigation of the flame-spread rate and combustion-product evolution of the burning of typical thicknesses of spacecraft materials in very low-speed flows; (2) an evaluation of the interaction of fires and candidate extinguishers in various fire scenarios; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion. Each experiment is expected to provide fundamental combustion-science data, as well as the fire-safety applications, and each requires the unique long-duration, low-gravity environment of the space station. Two generic test facilities, i.e., the Combustion Tunnel Facility and the Combustion Facility, are proposed for space station accommodation to support the selected experiments. In addition, three near-term, fire-safety related experiments are described along with other related precursor activities.

  20. Consequences of Fire: The Killing Fumes

    MedlinePlus

    ... Electric Vehicles Fire Fighter Safety and Response for Solar Power Systems Fire Fighting Tactics Under Wind Driven ... Protection Devices Development of Fire Mitigations Solutions for PV Systems Installed on Building Roofs - Phase 1 Electric/ ...

  1. Systematic control of nonmetallic materials for improved fire safety

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The elements of a systematic fire safety program are summarized and consist of fire safety criteria, design considerations, testing of materials, development of nonmetallic materials, nonmetallic materials information systems, design reviews, and change control. The system described in this report was developed for the Apollo spacecraft. The system can, however, be tailored to many industrial, commercial, and military activities.

  2. Large-Scale Spacecraft Fire Safety Experiments in ISS Resupply Vehicles

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David

    2013-01-01

    Our understanding of the fire safety risk in manned spacecraft has been limited by the small scale of the testing we have been able to conduct in low-gravity. Fire growth and spread cannot be expected to scale linearly with sample size so we cannot make accurate predictions of the behavior of realistic scale fires in spacecraft based on the limited low-g testing to date. As a result, spacecraft fire safety protocols are necessarily very conservative and costly. Future crewed missions are expected to be longer in duration than previous exploration missions outside of low-earth orbit and accordingly, more complex in terms of operations, logistics, and safety. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low-gravity, the need for realistic scale testing at reduced gravity has been demonstrated. To address this concern, a spacecraft fire safety research project is underway to reduce the uncertainty and risk in the design of spacecraft fire safety systems by testing at nearly full scale in low-gravity. This project is supported by the NASA Advanced Exploration Systems Program Office in the Human Exploration and Operations Mission Directorate. The activity of this project is supported by an international topical team of fire experts from other space agencies to maximize the utility of the data and to ensure the widest possible scrutiny of the concept. The large-scale space flight experiment will be conducted on three missions; each in an Orbital Sciences Corporation Cygnus vehicle after it has deberthed from the ISS. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew allows the fire products to be released into the cabin. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the

  3. Expert systems applied to spacecraft fire safety

    NASA Technical Reports Server (NTRS)

    Smith, Richard L.; Kashiwagi, Takashi

    1989-01-01

    Expert systems are problem-solving programs that combine a knowledge base and a reasoning mechanism to simulate a human expert. The development of an expert system to manage fire safety in spacecraft, in particular the NASA Space Station Freedom, is difficult but clearly advantageous in the long-term. Some needs in low-gravity flammability characteristics, ventilating-flow effects, fire detection, fire extinguishment, and decision models, all necessary to establish the knowledge base for an expert system, are discussed.

  4. 29 CFR Appendix A to Subpart P of... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  5. 29 CFR Appendix A to Subpart P to... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  6. 29 CFR Appendix A to Subpart P of... - Model Fire Safety Plan (Non-Mandatory)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Model Fire Safety Plan (Non-Mandatory) A Appendix A to...—Model Fire Safety Plan (Non-Mandatory) Model Fire Safety Plan Note: This appendix is non-mandatory and provides guidance to assist employers in establishing a Fire Safety Plan as required in § 1915.502. Table...

  7. Navy Safety Center data on the effects of fire protection systems on electrical equipment

    NASA Astrophysics Data System (ADS)

    Levine, Robert S.

    1991-04-01

    Records of the Navy Safety Center, Norfolk, VA were reviewed to find data relevant to inadvertant operation of installed fire extinguishing systems in civilian nuclear power plants. Navy data show the incidence of collateral fire or other damage by fresh water on operating electrical equipment in submarines and in shore facilities is about the same as the civilian experience, about 30 percent. Aboard surface ships, however, the collateral damage incidence in much lower, about 15 percent. With sea water, the collateral damage incidence is at least 75 percent. It is concluded that the fire extinguisher water has to be contaminated, as by rust in sprinkler systems or deposited salt spray, for most collateral damage to occur. Reasons for inadvertant operation (or advertant operation) of firex systems at shore facilities, submarines, and surface ships resemble those for nuclear power plants. Mechanical or electrical failures lead the list, followed by mishaps during maintenance. Detector and alarm system failures are significant problems at Navy shore facilities, and significant at nuclear power plants. Fixed halon and CO2 systems in shore facilities cause no collateral damage. Lists of individual Navy incidents with water and with halon and carbon dioxide are included as appendices.

  8. Fire safety in transit systems fault tree analysis

    DOT National Transportation Integrated Search

    1981-09-01

    Fire safety countermeasures applicable to transit vehicles are identified and evaluated. This document contains fault trees which illustrate the sequences of events which may lead to a transit-fire related casualty. A description of the basis for the...

  9. Risk and Protective Factors for Fires, Burns, and Carbon Monoxide Poisoning in U.S. Households

    PubMed Central

    Runyan, Carol W.; Johnson, Renee M.; Yang, Jingzhen; Waller, Anna E.; Perkis, David; Marshall, Stephen W.; Coyne-Beasley, Tamera; McGee, Kara S.

    2011-01-01

    Background More needs to be known about the prevalence of risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households. Methods A random-digit-dial survey was conducted about home safety with 1003 respondents representing households in the continental United States. Descriptive statistics assess the prevalence of risk and protective factors for fires, burns, and carbon monoxide overall, and by demographic characteristics, household structure, region, and residential tenure. The data were weighted to adjust for nonresponse and to reflect the U.S. population. Results Although most respondents reported having a smoke alarm (97%), and 80% reported having one on each level of their home, <20% reported checking the alarm at least every 3 months. Seventy-one percent reported having a fire extinguisher, 29% had a carbon monoxide detector, and 51% of those living with at least one other person had a fire escape plan. Few could report the temperature of their hot water at the tap (9%), or the setting on the hot water heater (25%). Only 6% had an antiscald device. Conclusions Results suggest that there is much room for improvement regarding adoption of measures to prevent fires, burns, and carbon monoxide poisoning. Further investigations of the efficacy of carbon monoxide detectors, fire extinguishers, and escape plans, as well as effectiveness studies of fire and burn-prevention efforts are needed. PMID:15626564

  10. Risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households.

    PubMed

    Runyan, Carol W; Johnson, Renee M; Yang, Jingzhen; Waller, Anna E; Perkis, David; Marshall, Stephen W; Coyne-Beasley, Tamera; McGee, Kara S

    2005-01-01

    More needs to be known about the prevalence of risk and protective factors for fires, burns, and carbon monoxide poisoning in U.S. households. A random-digit-dial survey was conducted about home safety with 1003 respondents representing households in the continental United States. Descriptive statistics assess the prevalence of risk and protective factors for fires, burns, and carbon monoxide overall, and by demographic characteristics, household structure, region, and residential tenure. The data were weighted to adjust for nonresponse and to reflect the U.S. population. Although most respondents reported having a smoke alarm (97%), and 80% reported having one on each level of their home, <20% reported checking the alarm at least every 3 months. Seventy-one percent reported having a fire extinguisher, 29% had a carbon monoxide detector, and 51% of those living with at least one other person had a fire escape plan. Few could report the temperature of their hot water at the tap (9%), or the setting on the hot water heater (25%). Only 6% had an antiscald device. Results suggest that there is much room for improvement regarding adoption of measures to prevent fires, burns, and carbon monoxide poisoning. Further investigations of the efficacy of carbon monoxide detectors, fire extinguishers, and escape plans, as well as effectiveness studies of fire and burn-prevention efforts are needed.

  11. Development of Large-Scale Spacecraft Fire Safety Experiments

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David; Fernandez-Pello, A. Carlos; T'ien, James S.; Torero, Jose L.; Legros, Guillaume; Eigenbrod, Christian; Smirnov, Nickolay; Fujita, Osamu; Cowlard, Adam J.; hide

    2013-01-01

    The status is presented of a spacecraft fire safety research project that is under development to reduce the uncertainty and risk in the design of spacecraft fire safety systems by testing at nearly full scale in low-gravity. Future crewed missions are expected to be more complex and longer in duration than previous exploration missions outside of low-earth orbit. This will increase the challenge of ensuring a fire-safe environment for the crew throughout the mission. Based on our fundamental uncertainty of the behavior of fires in low-gravity, the need for realistic scale testing at reduced gravity has been demonstrated. To address this gap in knowledge, a project has been established under the NASA Advanced Exploration Systems Program under the Human Exploration and Operations Mission directorate with the goal of substantially advancing our understanding of the spacecraft fire safety risk. Associated with the project is an international topical team of fire experts from other space agencies who conduct research that is integrated into the overall experiment design. The experiments are under development to be conducted in an Orbital Science Corporation Cygnus vehicle after it has undocked from the ISS. Although the experiment will need to meet rigorous safety requirements to ensure the carrier vehicle does not sustain damage, the absence of a crew removes the need for strict containment of combustion products. The tests will be fully automated with the data downlinked at the conclusion of the test before the Cygnus vehicle reenters the atmosphere. A computer modeling effort will complement the experimental effort. The international topical team is collaborating with the NASA team in the definition of the experiment requirements and performing supporting analysis, experimentation and technology development. The status of the overall experiment and the associated international technology development efforts are summarized.

  12. Occupancy Fire Record: Schools.

    ERIC Educational Resources Information Center

    National Fire Protection Association, Boston, MA.

    The considerations of human safety and preservation of facilities are examined in relation to school fires. Various aspects of planning which would decrease the probability of fires and thereby save life and property are reviewed and include--(1) causes, (2) automatic protection devices, (3) evacuation and fire drills, and (4) construction…

  13. School Fire Safety. Bulletin, 1951, No. 13

    ERIC Educational Resources Information Center

    Viles, N. E.

    1951-01-01

    School fires endanger pupils' lives and take annually a heavy toll in school property losses. If not controlled, these potentials may be changed quickly into serious losses. School officials, teachers, parents, and the public have an interest in school fire safety. Because of other interests and a lack of assigned responsibility in this area fire…

  14. 30 CFR 75.1107-16 - Inspection of fire suppression devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...

  15. 30 CFR 75.1107-16 - Inspection of fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...

  16. Fire safety of ground-based space facilities on the spaceport ;Vostochny;

    NASA Astrophysics Data System (ADS)

    Artamonov, Vladimir S.; Gordienko, Denis M.; Melikhov, Anatoly S.

    2017-06-01

    The facilities of the spaceport ;Vostochny; and the innovative technologies for fire safety to be implemented are considered. The planned approaches and prospects for fire safety ensuring at the facilities of the spaceport ;Vostochny; are presented herein, based on the study of emergency situations having resulted in fire accidents and explosion cases at the facilities supporting space vehicles operation.

  17. Solution of Fire Protection in Historic Buildings

    NASA Astrophysics Data System (ADS)

    Iringová, Agnes; Idunk, Róbert

    2016-12-01

    The paper introduces optimization of the functional use of renovated spaces in historic buildings in terms of fire risk. It brings assessment of fire protection in the folk house Habánsky Dvor, situated in the village of Veľké Leváre, whose function was changed into the museum. It goes into static analysis of existing load-bearing structures and assessment of their fire resistance according to Eurocodes.

  18. 49 CFR 176.315 - Fire protection requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Detailed Requirements for Class 3 (Flammable) and Combustible Liquid Materials § 176.315 Fire protection... (flammable) or combustible liquid for which it is required. Each fire extinguisher must be accessible to the... (flammable) and combustible liquids stowage areas must be fitted with an approved combination solid stream...

  19. 46 CFR 28.155 - Excess fire detection and protection equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Excess fire detection and protection equipment. 28.155... protection equipment. Installation of fire detection and protection equipment in excess of that required by the regulations in this subchapter is permitted provided that the excess equipment does not endanger...

  20. 46 CFR 28.380 - General structural fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... accommodation space must be separated from machinery and fuel tank spaces by a fire resistant boundary which... 46 Shipping 1 2010-10-01 2010-10-01 false General structural fire protection. 28.380 Section 28..., 1991, and That Operate With More Than 16 Individuals on Board § 28.380 General structural fire...

  1. Fire protection for launch facilities using machine vision fire detection

    NASA Astrophysics Data System (ADS)

    Schwartz, Douglas B.

    1993-02-01

    Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

  2. Fire protection for launch facilities using machine vision fire detection

    NASA Technical Reports Server (NTRS)

    Schwartz, Douglas B.

    1993-01-01

    Fire protection of critical space assets, including launch and fueling facilities and manned flight hardware, demands automatic sensors for continuous monitoring, and in certain high-threat areas, fast-reacting automatic suppression systems. Perhaps the most essential characteristic for these fire detection and suppression systems is high reliability; in other words, fire detectors should alarm only on actual fires and not be falsely activated by extraneous sources. Existing types of fire detectors have been greatly improved in the past decade; however, fundamental limitations of their method of operation leaves open a significant possibility of false alarms and restricts their usefulness. At the Civil Engineering Laboratory at Tyndall Air Force Base in Florida, a new type of fire detector is under development which 'sees' a fire visually, like a human being, and makes a reliable decision based on known visual characteristics of flames. Hardware prototypes of the Machine Vision (MV) Fire Detection System have undergone live fire tests and demonstrated extremely high accuracy in discriminating actual fires from false alarm sources. In fact, this technology promises to virtually eliminate false activations. This detector could be used to monitor fueling facilities, launch towers, clean rooms, and other high-value and high-risk areas. Applications can extend to space station and in-flight shuttle operations as well; fiber optics and remote camera heads enable the system to see around obstructed areas and crew compartments. The capability of the technology to distinguish fires means that fire detection can be provided even during maintenance operations, such as welding.

  3. 33 CFR 127.1507 - Water systems for fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Water systems for fire protection... HAZARDOUS GAS Waterfront Facilities Handling Liquefied Hazardous Gas Firefighting Equipment § 127.1507 Water systems for fire protection. (a) Each waterfront facility handling LHG must have a supply of water and a...

  4. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...

  5. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...

  6. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection Handbook, National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. B. Accident.... Private Fire Brigades, NFPA 27; National Fire Protection Association, Batterymarch Park, Quincy, MA 02269..., Batterymarch Park, Quincy, MA 02269 . 3. Fire Fighter Professional Qualifications, NFPA 1001; National Fire...

  7. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2012-10-01 2012-10-01 false Insulation, other than for structural fire protection...

  8. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2010-10-01 2010-10-01 false Insulation, other than for structural fire protection...

  9. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2014-10-01 2014-10-01 false Insulation, other than for structural fire protection...

  10. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2011-10-01 2011-10-01 false Insulation, other than for structural fire protection...

  11. 46 CFR 72.05-40 - Insulation, other than for structural fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... VESSELS CONSTRUCTION AND ARRANGEMENT Structural Fire Protection § 72.05-40 Insulation, other than for structural fire protection. (a) Any insulation installed for heat and comfort, refrigeration (including air... 46 Shipping 3 2013-10-01 2013-10-01 false Insulation, other than for structural fire protection...

  12. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a thorough knowledge and understanding of the principles of physics and chemistry governing fire growth...

  13. Research Needs in Fire Safety for the Human Exploration and Utilization of Space

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.

    2003-01-01

    This viewgraph presentation provides information on developments in spacecraft fire safety research. The presentation includes an overview of the previous Spacecraft Fire Safety Workshop, from 1986, and the influences since then of bioastronautics on combustion science and fire safety. The presentation then gives of overview of the current conference, stating goals and giving a schedule.

  14. Is Fire Safety a Burning Issue for Your Home?

    ERIC Educational Resources Information Center

    Haines, Jamie E.

    1986-01-01

    Families can take an active role in protecting their homes and themselves from fire by: (1) keeping their homes free of fire hazards; (2) installing, testing, and maintaining smoke detectors; and (3) developing a fire escape plan. (DF)

  15. 14 CFR 29.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction Fire Protection... sources, including electrical faults, overheating of equipment, and malfunctioning of protective devices...

  16. Alternative approach for fire suppression of class A, B and C fires in gloveboxes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberger, Mark S; Tsiagkouris, James A

    2011-02-10

    Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, ismore » capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.« less

  17. 29 CFR 1926.151 - Fire prevention.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 8 2013-07-01 2013-07-01 false Fire prevention. 1926.151 Section 1926.151 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.151 Fire... at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted...

  18. 29 CFR 1926.151 - Fire prevention.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 8 2014-07-01 2014-07-01 false Fire prevention. 1926.151 Section 1926.151 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.151 Fire... at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted...

  19. 29 CFR 1926.151 - Fire prevention.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 8 2012-07-01 2012-07-01 false Fire prevention. 1926.151 Section 1926.151 Labor... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Fire Protection and Prevention § 1926.151 Fire... at or in the vicinity of operations which constitute a fire hazard, and shall be conspicuously posted...

  20. Spacecraft Fire Safety and Microgravity Combustion Research

    NASA Technical Reports Server (NTRS)

    Tien, James S.; Ferkul, Paul (Technical Monitor)

    2001-01-01

    Fire safety is an important concern in our daily lives and it plays a special role in the human presence in space. In a spacecraft, the outside environment is hostile and the opportunity to escape is small. Rescue missions are difficult and time consuming. As a result, we should avoid the occurrence of fires in spacecraft as much as possible. If a fire occurs, we need to keep it small and under control. This implies that the materials used on board the spacecraft should be screened carefully, all the machines and devices need to be operated without accident, and fire detectors have to function properly. Once a fire is detected, it can be extinguished quickly and the cabin can be cleaned up to restore operation and sustain life.

  1. 30 CFR 75.1107-13 - Approval of other fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...

  2. 14 CFR 25.863 - Flammable fluid fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Fire Protection § 25..., including electrical faults, overheating of equipment, and malfunctioning of protective devices. (4) Means...

  3. 29 CFR 1915.505 - Fire response.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...

  4. 29 CFR 1915.505 - Fire response.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...

  5. 29 CFR 1915.505 - Fire response.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...

  6. 29 CFR 1915.505 - Fire response.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...

  7. 29 CFR 1915.505 - Fire response.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...

  8. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  9. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  10. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  11. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  12. 30 CFR 75.1107 - Fire suppression devices.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  13. 14 CFR 29.1359 - Electrical system fire and smoke protection.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Electrical Systems and Equipment § 29.1359 Electrical system fire and smoke protection. (a) Components of the electrical system... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Electrical system fire and smoke protection...

  14. The usage of phase change materials in fire fighter protective clothing: its effect on thermal protection

    NASA Astrophysics Data System (ADS)

    Zhao, Mengmeng

    2017-12-01

    The thermal protective performance of the fire fighter protective clothing is of vital importance for fire fighters. In the study fabrics treated by phase change materials (PCMs) were applied in the multi-layered fabrics of the fire fighter protective clothing ensemble. The PCM fabrics were placed at the different layers of the clothing and their thermal protective performance were measured by a TPP tester. Results show that with the application of the PCM fabrics the thermal protection of the multi-layered fabrics was greatly increased. The time to reach a second degree burn was largely reduced. The location of the PCM fabrics at the different layers did not affect much on the thermal protective performance. The higher amount of the PCM adds on, the higher thermal protection was brought. The fabrics with PCMs of a higher melting temperature could contribute to higher thermal protection.

  15. 78 FR 17140 - Upholstered Furniture Fire Safety Technology; Meeting and Request for Comments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... Furniture Fire Safety Technology; Meeting and Request for Comments AGENCY: Consumer Product Safety... Commission (CPSC, Commission, or we) is announcing its intent to hold a meeting on upholstered furniture fire... http://www.cpsc.gov/meetingsignup.html and click on the link titled, ``Upholstered Furniture Fire...

  16. 14 CFR 33.17 - Fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... STANDARDS: AIRCRAFT ENGINES Design and Construction; General § 33.17 Fire protection. (a) The design and... addition, the design and construction of turbine engines must minimize the probability of the occurrence of...

  17. 30 CFR 77.1100 - Fire protection; training and organization.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....1100 Section 77.1100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF... facilities and equipment shall be provided commensurate with the potential fire hazards at each structure...

  18. A study on fire spreading model for the safety distance between the neighborhood occupancies and historical buildings in Taiwan

    NASA Astrophysics Data System (ADS)

    Chen, C. H.; Chien, S. W.; Ho, M. C.

    2015-08-01

    Cultural heritages and historical buildings are vulnerable against severe threats from fire. Since the 1970s, ten fire-spread events involving historic buildings have occurred in Taiwan, affecting a total of 132 nearby buildings. Developed under the influence of traditional Taiwanese culture, historic buildings in Taiwan are often built using non-fire resistant brick-wood structure and located in proximity to residential occupancies. Fire outbreak in these types of neighborhood will lead to severe damage of antiquities, leaving only unrecoverable historical imagery. This study is aimed to investigate the minimal safety distance required between a historical building and its surroundings in order to reduce the risk of external fire. This study is based on literature analysis and the fire spread model using a Fire Dynamics Simulator. The selected target is Jingmei Temple in Taipei City. This study explored local geography to identify patterns behind historical buildings distribution. In the past, risk reduction engineering for cultural heritages and historical buildings focused mainly on fire equipment and the available personnel with emergency response ability, and little attention was given to external fire risks and the affected damage. Through discussions on the required safety distance, this research provides guidelines for the following items: management of neighborhoods with historical buildings and consultation between the protection of cultural heritages and disaster prevention, reducing the frequency and extent of fire damages, and preserving cultural resource.

  19. Commonalities in Transportation Fire Safety : Regulations, Research and Development, and Data Bases

    DOT National Transportation Integrated Search

    1980-01-01

    This report presents a comprehensive review of current modal fire safety efforts within the U.S. Department of Transportation. Common fire safety problems and modal administration response are identified. Work completed includes a review of modal adm...

  20. 78 FR 55765 - Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-11

    ... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Draft..., ``Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN-FIRE).'' In... integral part of NRC-approved fire protection programs. However, compensatory measures are not expected to...

  1. Engineering and Development Program Plan, Aircraft Cabin Fire Safety.

    DTIC Science & Technology

    1980-06-01

    relative to a postcrash fuel fire, or whether advanced materials provide a significant safety benefit in comparison to inservice materials. if either...have always been controlled by early detection and prompt extinguishment action by effectively trained crew members. In addition, the fire resistant...occupants. g. Develop a computer fire test data bank with broad user availability for inservice and candidate cabin interior materials. h. Identify

  2. 46 CFR 28.825 - Excess fire detection and protection equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Excess fire detection and protection equipment. 28.825... equipment. Instead of meeting the requirements of § 28.155, each vessel to which this subpart applies must meet the following requirements: (a) Installation of fire detection and protection equipment in excess...

  3. 29 CFR 1926.352 - Fire prevention.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...

  4. Is Your School Truly Fire-Safe?

    ERIC Educational Resources Information Center

    Saunders, Carol Silverman

    1995-01-01

    Though most people assume that their schools are protected by smoke alarms and sprinkler systems, many are not. Older schools can fall through fire-code loopholes. Some schools have insufficient fire detection systems. Sprinkler systems can be too expensive for schools. Parents should educate themselves and insist on fire safety. (SM)

  5. 29 CFR 1926.352 - Fire prevention.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...

  6. 29 CFR 1926.352 - Fire prevention.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...

  7. 29 CFR 1926.352 - Fire prevention.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Welding and Cutting § 1926.352 Fire prevention. (a... confine the heat, sparks, and slag, and to protect the immovable fire hazards from them. (c) No welding... for instant use. (e) When the welding, cutting, or heating operation is such that normal fire...

  8. Findings of a review of spacecraft fire safety needs

    NASA Technical Reports Server (NTRS)

    Apostolakis, G. E.; Catton, I.; Paulos, T.; Paxton, K.; Jones, S.

    1992-01-01

    Discussions from a workshop to guide UCLA and NASA investigators on the state of knowledge and perceived needs in spacecraft fire safety and its risk management are reviewed, for an introduction to an analytical and experimental project in this field. The report summarizes the workshop discussions and includes the visual aids used in the presentations. Probabilistic Safety Assessment (PSA) methods, which are currently not used, would be of great value to the designs and operation of future human-crew spacecraft. Key points in the discussions were the importance of understanding and testing smoldering as a likely fire scenario in space and the need for smoke damage modeling, since many fire-risk models ignore this mechanism and consider only heat damage.

  9. Crew Exploration Vehicle Environmental Control and Life Support Fire Protection Approach

    NASA Technical Reports Server (NTRS)

    Lewis, John F.; Barido, Richard; Tuan, George C.

    2007-01-01

    As part of preparing for the Crew Exploration Vehicle (CEV), the National Aeronautics and Space Administration (NASA) worked on developing the requirements to manage the fire risk. The new CEV poses unique challenges to current fire protection systems. The size and configuration of the vehicle resembles the Apollo capsule instead of the current Space Shuttle or the International Space Station. The smaller free air volume and fully cold plated avionic bays of the CEV requires a different approach in fire protection than the ones currently utilized. The fire protection approach discussed in this paper incorporates historical lessons learned and fire detection and suppression system design philosophy spanning from Apollo to the International Space Station. Working with NASA fire and materials experts, this approach outlines the best requirements for both the closed out area of the vehicle, such as the avionics bay, and the crew cabin area to address the unique challenges due to the size and configuration of the CEV.

  10. Deformation and Heat Transfer on Three Sides Protected Beams under Fire Accident

    NASA Astrophysics Data System (ADS)

    Imran, M.; Liew, M. S.; Garcia, E. M.; Nasif, M. S.; Yassin, A. Y. M.; Niazi, U. M.

    2018-04-01

    Fire accidents are common in oil and gas industry. The application of passive fire protection (PFP) is a costly solution. The PFP is applied only on critical structural members to optimise project cost. In some cases, beams cannot be protected from the top flange in order to accommodate for the placement of pipe supports and grating. It is important to understand the thermal and mechanical response of beam under such condition. This paper discusses the response of steel beam under ISO 834 fire protected, unprotected and three sides protected beams. The model validated against an experimental study. The experimental study has shown good agreement with FE model. The study revealed that the beams protected from three sides heat-up faster compare to fully protected beam showing different temperature gradient. However, the affects load carrying capacity are insignificant under ISO 834 fire.

  11. Motorcoach and school bus fire safety analysis : technology brief.

    DOT National Transportation Integrated Search

    2016-11-01

    In 2009, the Federal Motor Carrier Safety Administration (FMCSA) published findings from a study entitled Motorcoach Fire Safety Analysis. The objective of this study was to gather and analyze information regarding the causes, frequency, and se...

  12. Study of aircraft crashworthiness for fire protection

    NASA Technical Reports Server (NTRS)

    Cominsky, A.

    1981-01-01

    Impact-survivable postcrash fire accidents were surveyed. The data base developed includes foreign and domestic accidents involving airlines and jet aircraft. The emphasis was placed on domestic accidents, airlines, and jet aircraft due principally to availability of information. Only transport category aircraft in commercial service designed under FAR Part 25 were considered. A matrix was prepared to show the relationships between the accident characteristics and the fire fatalities. Typical postcrash fire scenaries were identified. Safety concepts were developed for three engineering categories: cabin interiors - cabin subsystems; power plant - engines and fuel systems; and structural mechanics - primary and secondary structures. The parameters identified for concept evaluation are cost, effectiveness, and societal concerns. Three concepts were selected for design definition and cost and effectiveness analysis: improved fire-resistant seat materials; anti-misting kerosene; and additional cabin emergency exits.

  13. Fire Safety Tests for Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dong-Sang; Peterson, Reid A.; Schweiger, Michael J.

    2012-07-30

    A draft safety evaluation of the scenario for spherical resorcinol-formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping, which may be overly bounding based on the fire performance data from the manufacturer of the ion exchange resin selected for use at the WTP. To resolve this question, the fire properties of the SRF resin were measuredmore » by Southwest Research Institute (SwRI), following the American Society for Testing and Materials (ASTM) standard procedures, through a subcontract managed by Pacific Northwest National Laboratory (PNNL). For some tests, the ASTM standard procedures were not entirely appropriate or practical for the SRF resin material, so the procedures were modified and deviations from the ASTM standard procedures were noted. This report summarizes the results of fire safety tests performed and reported by SwRI. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. All as-received SwRI reports are attached to this report in the Appendix. Where applicable, the precision and bias of each test method, as given by each ASTM standard procedure, are included and compared with the SwRI test results of the SRF resin.« less

  14. Fire technology abstracts, volume 4. Cumulative indexes

    NASA Astrophysics Data System (ADS)

    1982-03-01

    Cumulative subject, author, publisher, and report number indexes referencing articles, books, reports, and patents are provided. The dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, and insurance economics of loss and prevention are among the subjects covered.

  15. Accidental fires in clinical laboratories.

    PubMed

    Hoeltge, G A; Miller, A; Klein, B R; Hamlin, W B

    1993-12-01

    The National Fire Protection Association, Quincy, Mass, estimates that 169 fires have occurred annually in health care, medical, and chemical laboratories. On the average, there are 13 civilian injuries and $1.5 million per year in direct property damage. Most fires in which the cause or ignition source can be identified originate in malfunctioning electrical equipment (41.6%) or in the facility's electrical distribution system (14.7%). The prevalence of fire safety deficiencies was measured in the College of American Pathologists Laboratory Accreditation Program. Of the 1732 inspected laboratories, 5.5% lacked records of electrical receptacle polarity and ground checks in the preceding year. Of these inspected laboratories, 4.7% had no or incomplete documentation of electrical safety checks on laboratory instruments. There was no evidence of quarterly fire exit drills in 9% of the laboratories. Deficiencies were also found in precautionary labeling (6.8%), in periodic review of safe work practices (4.2%), in the use of safety cans (3.7%), and in venting of flammable liquid storage areas (2.8%). Fire preparedness would be improved if all clinical laboratories had smoke detectors and automatic fire-extinguishing systems. In-service training courses in fire safety should be targeted to the needs of specific service areas.

  16. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  17. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  18. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  19. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  20. 30 CFR 77.1916 - Welding, cutting, and soldering; fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Welding, cutting, and soldering; fire... OF UNDERGROUND COAL MINES Slope and Shaft Sinking § 77.1916 Welding, cutting, and soldering; fire protection. (a) One portable fire extinguisher shall be provided where welding, cutting, or soldering with...

  1. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  2. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  3. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  4. 41 CFR 102-80.135 - Who is a qualified fire protection engineer?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... protection engineer? 102-80.135 Section 102-80.135 Public Contracts and Property Management Federal Property... qualified fire protection engineer? A qualified fire protection engineer is defined as an individual with a..., spread, and suppression, meeting one of the following criteria: (a) An engineer having an undergraduate...

  5. Partially Premixed Flame (PPF) Research for Fire Safety

    NASA Technical Reports Server (NTRS)

    Puri, Ishwar K.; Aggarwal, Suresh K.; Lock, Andrew J.; Hegde, Uday

    2004-01-01

    Incipient fires typically occur after the partial premixing of fuel and oxidizer. The mixing of product species into the fuel/oxidizer mixture influences flame stabilization and fire spread. Therefore, it is important to characterize the impact of different levels of fuel/oxidizer/product mixing on flame stabilization, liftoff and extinguishment under different gravity conditions. With regard to fire protection, the agent concentration required to achieve flame suppression is an important consideration. The initial stage of an unwanted fire in a microgravity environment will depend on the level of partial premixing and the local conditions such as air currents generated by the fire itself and any forced ventilation (that influence agent and product mixing into the fire). The motivation of our investigation is to characterize these impacts in a systematic and fundamental manner.

  6. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  7. A qualitative evaluation of fire safety education programs for older adults.

    PubMed

    Diekman, Shane T; Stewart, Tamara A; Teh, S Leesia; Ballesteros, Michael F

    2010-03-01

    This article presents a qualitative evaluation of six fire safety education programs for older adults delivered by public fire educators. Our main aims were to explore how these programs are implemented and to determine important factors that may lead to program success, from the perspectives of the public fire educators and the older adults. For each program, we interviewed the public fire educator(s), observed the program in action, and conducted focus groups with older adults attending the program. Analysis revealed three factors that were believed to facilitate program success (established relationships with the older adult community, rapport with older adult audiences, and presentation relevance) as well as three challenges (lack of a standardized curriculum and program implementation strategies, attendance difficulties, and physical limitations due to age). More fire safety education should be developed for older adult populations. For successful programs, public fire educators should address the specific needs of their local older adult community.

  8. An Educational Program Dealing with Fire Safety. Curriculum and Resource Guide.

    ERIC Educational Resources Information Center

    Rhode Island State Dept. of Education, Providence.

    A series of activities for fire safety education in grades K-12 is presented. The document is organized into three parts: grades K-3; 4-6; and 7-12. Each activity is preceded by general and specific concepts to be stressed. Concepts for grades K-3 stress usefulness and types of fire, fire drills, the fire fighting profession, and the…

  9. 14 CFR 27.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...

  10. 14 CFR 27.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 27.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, rotor mechanism, and other parts essential to a controlled landing that would be affected by...

  11. 14 CFR 29.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...

  12. 14 CFR 29.861 - Fire protection of structure, controls, and other parts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of structure, controls, and... Protection § 29.861 Fire protection of structure, controls, and other parts. Each part of the structure, controls, and the rotor mechanism, and other parts essential to controlled landing and (for category A...

  13. 78 FR 45573 - Compensatory and Alternative Regulatory Measures for Nuclear Power Plant Fire Protection (CARMEN...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-29

    ... Nuclear Power Plant Fire Protection (CARMEN-FIRE) AGENCY: Nuclear Regulatory Commission. ACTION: Notice of... Nuclear Power Plant Fire Protection (CARMEN-FIRE), Draft Report for Comment.'' DATES: Comments on this... CONTACT: Felix Gonzalez, Fire Research Branch, Division of Risk Analysis, Office of Nuclear Regulatory...

  14. Using Modeling and Rehearsal to Teach Fire Safety to Children with Autism

    ERIC Educational Resources Information Center

    Garcia, David; Dukes, Charles; Brady, Michael P.; Scott, Jack; Wilson, Cynthia L.

    2016-01-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to…

  15. Fire Extinguisher Designated Worker and Fire Watch: Self-Study Course 15672

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Jimmy D.

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code ofmore » Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.« less

  16. Fire Extinguisher Training for Fire Watch and Designated Workers, Course 9893

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Jimmy D.

    At Los Alamos National Laboratory (LANL), all workers must be aware of LANL fire protection policies and be trained on what to do in the event of a fire. This course, Fire Extinguisher Training for Fire Watch and Designated Workers (#9893), provides awareness-level and hands-on training for fire watch personnel and designated workers. Fire watch personnel and designated workers are appointed by line management and must receive both awareness-level training and hands-on training in the use of portable fire extinguishers to extinguish an incipient-stage fire. This training meets the requirements of the Occupational Safety and Health Administration (OSHA) Code ofmore » Federal Regulations (CFR) 29 CFR 1910.157, Portable Fire Extinguishers, and Procedure (P) 101-26, Welding, Cutting, and Other Spark-/Flame-Producing Operations.« less

  17. Fire Safety of Passenger Trains : Phase II : Application of Fire Hazard Analysis Techniques

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  18. Fire safety of passenger trains. Phase II, Application of fire hazard analysis techniques.

    DOT National Transportation Integrated Search

    2001-12-01

    On May 12, 1999, the Federal Railroad Administration (FRA) issued regulations for passenger rail equipment safety standards that included small-scale fire tests and performance criteria to evaluate the flammability and smoke characteristics of indivi...

  19. Fire-related medical science

    NASA Technical Reports Server (NTRS)

    Knight, Douglas R.

    1987-01-01

    Spacecraft fire safety may be improved by the use of a fire-retardant atmosphere in occupied spaces. Low concentrations of oxygen can protect humans from fire damage by reducing the rate and spread of combustion, but care must be taken to avoid the hypoxic effects of oxygen-lean atmospheres. Crews can live and work in 11 percent oxygen if barometric pressure were adjusted to maintain the partial pressure of oxygen above 16 kPa. Eleven percent oxygen should prevent most types of fires, since 15 percent oxygen retards the combustion of paper and 13 percent oxygen extinguishes pentane flames. Test results indicate that seated humans can perform mental tasks in atmospheres containing 11.5 percent oxygen. Although this strategy of fire safety is under consideration for submarines, it could be adapted to spacecraft once operational procedures define a maximum hyperbaric pressure and fire research defines the effects of reduced oxygen concentrations on combustion in low gravity environments.

  20. Evaluating a smartphone application to improve child passenger safety and fire safety knowledge and behaviour.

    PubMed

    Omaki, Elise; Shields, Wendy C; McDonald, Eileen; Aitken, Mary E; Bishai, David; Case, James; Gielen, Andrea

    2017-02-01

    Although proven measures for reducing injury due to motor vehicle collision and residential fires exist, the number of families properly and consistently using child passenger restraints and smoke alarms remains low. This paper describes the design of the Safety In Seconds (SIS) 2.0 study, which aims to evaluate the impact of a smartphone app on parents' use of child restraints and smoke alarms. SIS is a multisite randomised controlled trial. Participants are parents of children aged 4-7 years who are visiting the Pediatric Emergency Department or Pediatric Trauma Service. Parents are randomised to receive tailored education about child passenger safety or about fire safety via the SIS smartphone app. A baseline and two follow-up surveys at 3 months and 6 months are conducted. Primary outcomes are: (1) having the correct child restraint for the child's age and size; (2) restraining the child in the back seat of the car; (3) buckling the child up for every ride; (4) having the restraint inspected by a child passenger safety technician; (5) having a working smoke alarm on every level of the home; (6) having hard-wired or lithium battery smoke alarms; (7) having and (8) practising a fire escape plan. Finding ways to communicate with parents about child passenger and fire safety continues to be a research priority. This study will contribute to the evidence about how to promote benefits of proper and consistent child restraint and smoke alarm use. NCT02345941; Pre-results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. Fire Technology Abstracts, volume 4, issue 1, August, 1981

    NASA Astrophysics Data System (ADS)

    Holtschlag, L. J.; Kuvshinoff, B. W.; Jernigan, J. B.

    This bibliography contains over 400 citations with abstracts addressing various aspects of fire technology. Subjects cover the dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention, suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, insurance, economics of loss and prevention, and more.

  2. Community partnership to promote home fire safety in children with special needs.

    PubMed

    Lehna, Carlee; Janes, Erika G; Rengers, Sharon; Graviss, Jackie; Scrivener, Drane; Knabel, Tom; Carver, Elizabeth; Myers, John

    2014-09-01

    Parents of children with special needs are vigilant as their child may have difficulty independently escaping a burning home. The purpose of this study was to evaluate if providing home fire safety information via a digital video disc (DVD) increases families' knowledge, behavior and ability regarding home fire safety. A school based classroom intervention (using a home fire safety DVD) was provided to parents (n=40) of children with and without special needs to improve home fire safety knowledge, behavior and ability. In addition, parents seen at the Kentucky Commission for Children with Special Health Care Needs clinics (n=47) received the same intervention in cohorts of 1-2 children. For both groups, knowledge, and behavior were measured before and after intervention. Repeated measures ANOVA were used to test for differences between groups and over time. Significance was set at p<0.05. No difference in scores between pre- and post-test scores existed between groups (with special needs vs. without special needs, or classroom vs. individualized instruction). However, some differences were noted for some individual survey questions during post-hoc comparisons. Having a smoke alarm in the home (90% vs. 95%, p=0.029) and having a smoke alarm outside of where everyone sleeps (75% vs. 95%, p=0.005) increased over time and was retained. Having a fire escape plan increased at post intervention (58% vs. 79%, p=0.033), but returned to pre levels at follow-up (58%). Perceived knowledge (7.7 vs. 9.3, p<0.001) and ability (8.7 vs. 9.1, p=0.069) increased over time. Parents of children with special needs had a significant increase in knowledge and behavior over those parents of children without special needs. They also perceived having a high fire safety ability. Many of the post-test questions/behaviors (e.g., capable of exiting home during a fire, etc.) were reported at 100%. The intervention was well received, but may not necessarily be needed. Focus for home fire safety

  3. A Fire Safety Pre-Educational Plan.

    ERIC Educational Resources Information Center

    Rosenbaum, Lynn

    A weekly dance at a community center was used to develop a teachable moment for active senior citizens regarding fire safety, in order to reduce their injuries and possible loss of life. A target group of active senior citizens 70 years of age and older who frequent the weekly community center dance was established for the program. The program…

  4. Fire prevention in Delaware: a case study of fire and life safety initiatives.

    PubMed

    Frattaroli, Shannon; Gielen, Andrea C; Piver-Renna, Jennifer; Pollack, Keshia M; Ta, Van M

    2011-01-01

    Injuries resulting from residential house fires are a significant public health issue. The fire service is engaged in fire prevention activities aimed at preventing fire-related morbidity and mortality. The fire service in Delaware is regarded by some leaders in the field as a model for fire and life safety education (FLSE). We identified 3 questions to guide this research. What is the culture and context of fire prevention in Delaware? What prevention programs and policies constitute Delaware's fire prevention efforts? What can be learned from select model programs regarding their impact, sustainability, strengths, limitations, and general applicability? A discussion of the lessons learned from Delaware's experience with FLSE initiatives concludes the article. We used a single case study design and collected and analyzed data from in-depth interviews, documents, and participant observation notes to address the research questions. Data were collected in Delaware. Interviewees included a purposeful sample of members of the Delaware fire service. Descriptions of the context in which fire prevention occurs, the initiatives underway, and the factors associated with successfully supporting fire prevention in the state. Data from 16 key informant interviews, relevant documents, and direct observations of FLSE events revealed a fire service rooted in tradition, dedication, and community. A compilation of state and local FLSE initiatives illustrates the diversity of FLSE in Delaware. Thematic analysis of the data emphasize the importance of a strategic, comprehensive, and coordinated approach to realizing success in Delaware's approach to FLSE. The fire service is an important part of the public health infrastructure. While their role as first responders is evident, their contributions to prevention are also significant. This research suggests ways to support fire service prevention efforts and more fully integrate their FLSE work into the public health infrastructure.

  5. Risk reduction in road and rail LPG transportation by passive fire protection.

    PubMed

    Paltrinieri, Nicola; Landucci, Gabriele; Molag, Menso; Bonvicini, Sarah; Spadoni, Gigliola; Cozzani, Valerio

    2009-08-15

    The potential reduction of risk in LPG (Liquefied Petroleum Gas) road transport due to the adoption of passive fire protections was investigated. Experimental data available for small scale vessels fully engulfed by a fire were extended to real scale road and rail tankers through a finite elements model. The results of mathematical simulations of real scale fire engulfment scenarios that may follow accidents involving LPG tankers proved the effectiveness of the thermal protections in preventing the "fired" BLEVE (Boiling Liquid Expanding Vapour Explosion) scenario. The presence of a thermal coating greatly increases the "time to failure", providing a time lapse that in the European experience may be considered sufficient to allow the start of effective mitigation actions by fire brigades. The results obtained were used to calculate the expected reduction of individual and societal risk due to LPG transportation in real case scenarios. The analysis confirmed that the introduction of passive fire protections turns out in a significant reduction of risk, up to an order of magnitude in the case of individual risk and of about 50% if the expectation value is considered. Thus, the adoption of passive fire protections, not compulsory in European regulations, may be an effective technical measure for risk reduction, and may contribute to achieve the control of "major accidents hazards" cited by the European legislation.

  6. Resistance after firing protected electric match

    DOEpatents

    Montoya, Arsenio P.

    1981-11-10

    An electric match having electrical leads embedded in flame-producing compound is protected against an accidental resistance across the leads after firing by a length of heat-shrinkable tubing encircling the match body and having a skirt portion extending beyond the leads. The heat of the burning match and an adjacent thermal battery causes the tubing to fold over the end of the match body, covering the ends of the leads and protecting them from molten pieces of the battery.

  7. Fire hazard analysis for Plutonium Finishing Plant complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MCKINNIS, D.L.

    1999-02-23

    A fire hazards analysis (FHA) was performed for the Plutonium Finishing Plant (PFP) Complex at the Department of Energy (DOE) Hanford site. The scope of the FHA focuses on the nuclear facilities/structures in the Complex. The analysis was conducted in accordance with RLID 5480.7, [DOE Directive RLID 5480.7, 1/17/94] and DOE Order 5480.7A, ''Fire Protection'' [DOE Order 5480.7A, 2/17/93] and addresses each of the sixteen principle elements outlined in paragraph 9.a(3) of the Order. The elements are addressed in terms of the fire protection objectives stated in paragraph 4 of DOE 5480.7A. In addition, the FHA also complies with WHC-CM-4-41,more » Fire Protection Program Manual, Section 3.4 [1994] and WHC-SD-GN-FHA-30001, Rev. 0 [WHC, 1994]. Objectives of the FHA are to determine: (1) the fire hazards that expose the PFP facilities, or that are inherent in the building operations, (2) the adequacy of the fire safety features currently located in the PFP Complex, and (3) the degree of compliance of the facility with specific fire safety provisions in DOE orders, related engineering codes, and standards.« less

  8. An assessment of the impact of home safety assessments on fires and fire-related injuries: a case study of Cheshire Fire and Rescue Service.

    PubMed

    Arch, B N; Thurston, M N

    2013-06-01

    Deaths and injuries related to fires are largely preventable events. In the UK, a plethora of community-based fire safety initiatives have been introduced over the last 25 years, often led by fire and rescue services, to address this issue. This paper focuses on one such initiative--home safety assessments (HSAs). Cheshire Fire and Rescue Service (in England) implemented a uniquely large-scale HSA intervention. This paper assesses its effectiveness. The impact of HSAs was assessed in relation to three outcomes: accidental dwelling fires (ADFs), ADFs contained and injuries arising from ADFs. A two-period comparison in fire-related rates of incidences in Cheshire between 2002 and 2011 was implemented, using Poisson regression and adjusting for the national temporal trend using a control group comprising the 37 other English non-metropolitan fire-services. Significant reductions were observed in rates of ADFs [incidence rate ratios (IRR): 0.79, 95% confidence interval (CI): 0.74-0.83, P < 0.001, 2002/03-2007/08 versus 2008/09-2010/11] and associated injuries (IRR: 0.49, 95% CI: 0.39-0.60, P < 0.001, 2002/03-2006/07 versus 2007/08-2010/11), but not in the proportion of fires contained to room of origin. There is strong evidence to suggest that the intervention was successful in reducing domestic fires and related injuries.

  9. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  10. 36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  11. Fire and the Design of Educational Buildings. Building Bulletin 7. Sixth Edition.

    ERIC Educational Resources Information Center

    Department of Education and Science, London (England).

    This bulletin offers guidance on English school premises regulations applying to safety protection against fires in the following general areas: means of escape in case of fire; precautionary measures to prevent fire; fire warning systems and fire fighting; fire spreading speed; structures and materials resistant to fires; and damage control. It…

  12. Bibliography on aircraft fire hazards and safety. Volume 2: Safety. Part 1: Key numbers 1 to 524

    NASA Technical Reports Server (NTRS)

    Pelouch, J. J., Jr. (Compiler); Hacker, P. T. (Compiler)

    1974-01-01

    Bibliographic citations are presented to describe and define aircraft safety methods, equipment, and criteria. Some of the subjects discussed are: (1) fire and explosion suppression using whiffle balls, (2) ultraviolet flame detecting sensors, (3) evaluation of flame arrestor materials for aircraft fuel systems, (4) crash fire prevention system for supersonic commercial aircraft, and (5) fire suppression for aerospace vehicles.

  13. Children's Knowledge of Fire Safety. Stage 2. The Final Report for the New Zealand Fire Service.

    ERIC Educational Resources Information Center

    Dunn, Karyn; Renwick, Margery

    In 1991 the New Zealand Fire Service planned a primary school fire-safety education program for children from new entrants to form 2. The program introduces a new module to the children each year of their primary education. This study was undertaken in an attempt to measure the effectiveness of the program. A sample of 1,089 children completed…

  14. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Fire protection of flight controls, engine...

  15. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Fire protection of flight controls, engine...

  16. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire protection of flight controls, engine...

  17. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Fire protection of flight controls, engine...

  18. 14 CFR 25.865 - Fire protection of flight controls, engine mounts, and other flight structure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Design and Construction Fire Protection § 25.865 Fire protection of flight controls, engine mounts, and other flight structure. Essential flight controls, engine mounts, and other flight structures located in... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Fire protection of flight controls, engine...

  19. Behaviour of Passive Fire Protection K-Geopolymer under Successive Severe Fire Incidents.

    PubMed

    Sakkas, Konstantinos; Sofianos, Alexandros; Nomikos, Pavlos; Panias, Dimitrios

    2015-09-11

    The performance of a fire resistant coating for tunnel passive fire protection under successive severe thermal loading is presented. The material falls under the class of potassium based geopolymers (K-geopolymer) and was prepared by mixing ferronickel (FeNi) slag, doped with pure alumina, with a highly alkaline potassium hydroxide aqueous phase. Its performance was assessed by subjecting a concrete slab with a five cm thick K-geopolymer coating layer into successive RijksWaterStaat (RWS) fire incidents. During the first test, the maximum measured temperature in the K-geopolymer/concrete interface was 250 °C, which is 130 °C lower than the RWS test requirement, while, during the second fire test, the maximum temperature was almost 370 °C, which is still lower than the RWS requirement proving the effectiveness of the material as a thermal barrier. In addition, the material retained its structural integrity, during and after the two tests, without showing any mechanical or thermal damages.

  20. Behaviour of Passive Fire Protection K-Geopolymer under Successive Severe Fire Incidents

    PubMed Central

    Sakkas, Konstantinos; Sofianos, Alexandros; Nomikos, Pavlos; Panias, Dimitrios

    2015-01-01

    The performance of a fire resistant coating for tunnel passive fire protection under successive severe thermal loading is presented. The material falls under the class of potassium based geopolymers (K-geopolymer) and was prepared by mixing ferronickel (FeNi) slag, doped with pure alumina, with a highly alkaline potassium hydroxide aqueous phase. Its performance was assessed by subjecting a concrete slab with a five cm thick K-geopolymer coating layer into successive RijksWaterStaat (RWS) fire incidents. During the first test, the maximum measured temperature in the K-geopolymer/concrete interface was 250 °C, which is 130 °C lower than the RWS test requirement, while, during the second fire test, the maximum temperature was almost 370 °C, which is still lower than the RWS requirement proving the effectiveness of the material as a thermal barrier. In addition, the material retained its structural integrity, during and after the two tests, without showing any mechanical or thermal damages. PMID:28793554

  1. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  2. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  3. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  4. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  5. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  6. Halon Gas and Library Fire Protection.

    ERIC Educational Resources Information Center

    Pacey, Antony

    1991-01-01

    Describes the operation of halon gas fire extinguishing systems, which have been installed in a number of libraries and archives across Canada where protection of special collections from water and mold damage resulting from operation of a standard water sprinkler system is paramount. The advantages and disadvantages of this type of system are…

  7. Overview of safety research

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    Aircraft safety is reviewed by first establishing a perspective of air transportation accidents as a function of calendar year, geographic area, and phase of flight, and then by describing the threats to safety and NASA research underway in the three representative areas of engine operational problems, meteorological phenomena, and fire. Engine rotor burst protection, aircraft nacelle fire extinguishment, the aircraft-weather interface, severe weather wind shears and turbulence, clear air turbulence, and lightning are among the topics covered. Fire impact management through fire resistant materials technology development is emphasized.

  8. Fire propagation performance of intumescent fire protective coatings using eggshells as a novel biofiller.

    PubMed

    Yew, M C; Ramli Sulong, N H; Yew, M K; Amalina, M A; Johan, M R

    2014-01-01

    This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens' B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I) = 4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength.

  9. Fire Propagation Performance of Intumescent Fire Protective Coatings Using Eggshells as a Novel Biofiller

    PubMed Central

    Yew, M. C.; Ramli Sulong, N. H.; Yew, M. K.; Amalina, M. A.; Johan, M. R.

    2014-01-01

    This paper aims to synthesize and characterize an effective intumescent fire protective coating that incorporates eggshell powder as a novel biofiller. The performances of thermal stability, char formation, fire propagation, water resistance, and adhesion strength of coatings have been evaluated. A few intumescent flame-retardant coatings based on these three ecofriendly fire retardant additives ammonium polyphosphate phase II, pentaerythritol and melamine mixed together with flame-retardant fillers, and acrylic binder have been prepared and designed for steel. The fire performance of the coatings has conducted employing BS 476: Part 6-Fire propagation test. The foam structures of the intumescent coatings have been observed using field emission scanning electron microscopy. On exposure, the coated specimens' B, C, and D had been certified to be Class 0 due to the fact that their fire propagation indexes were less than 12. Incorporation of ecofriendly eggshell, biofiller into formulation D led to excellent performance in fire stopping (index value, (I) = 4.3) and antioxidation of intumescent coating. The coating is also found to be quite effective in water repellency, uniform foam structure, and adhesion strength. PMID:25136687

  10. 20 CFR 654.417 - Fire, safety, and first aid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Fire, safety, and first aid. 654.417 Section..., safety, and first aid. (a) All buildings in which people sleep or eat shall be constructed and maintained...-type water extinguisher. (g) First aid facilities shall be provided and readily accessible for use at...

  11. Materials research for aircraft fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Bricker, R. W.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of the state-of-the-art and the advanced bismaleimide composites are detailed.

  12. Eye Protection: Safety Glasses. Safety Spotlight

    ERIC Educational Resources Information Center

    Deck, Anita; Roy, Ken

    2017-01-01

    When it comes to eye safety, there are some situations in which regular safety glasses will work adequately for the needs of the STEM education classroom or laboratory. However, there are certain instances in which safety goggles must be used for safer protection. Taking the time to analyze hazards and assess the risks prior to any activity in the…

  13. Application of Graph Theory to Cost-Effective Fire Protection of Chemical Plants During Domino Effects.

    PubMed

    Khakzad, Nima; Landucci, Gabriele; Reniers, Genserik

    2017-09-01

    In the present study, we have introduced a methodology based on graph theory and multicriteria decision analysis for cost-effective fire protection of chemical plants subject to fire-induced domino effects. By modeling domino effects in chemical plants as a directed graph, the graph centrality measures such as out-closeness and betweenness scores can be used to identify the installations playing a key role in initiating and propagating potential domino effects. It is demonstrated that active fire protection of installations with the highest out-closeness score and passive fire protection of installations with the highest betweenness score are the most effective strategies for reducing the vulnerability of chemical plants to fire-induced domino effects. We have employed a dynamic graph analysis to investigate the impact of both the availability and the degradation of fire protection measures over time on the vulnerability of chemical plants. The results obtained from the graph analysis can further be prioritized using multicriteria decision analysis techniques such as the method of reference point to find the most cost-effective fire protection strategy. © 2016 Society for Risk Analysis.

  14. 76 FR 70413 - National Fire Protection Association (NFPA): Request for Comments on NFPA's Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-14

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Protection... (NIST) is publishing this notice on behalf of the National Fire Protection Association (NFPA) to..., (301) 975-4019. SUPPLEMENTARY INFORMATION: Since 1896, the National Fire Protection Association (NFPA...

  15. Experiments to ensure Space Station fire safety - A challenge

    NASA Technical Reports Server (NTRS)

    Youngblood, W. W.; Seiser, K. M.

    1988-01-01

    Three experiments have been formulated in order to address prominent fire safety requirements aboard the NASA Space Shuttle; these experiments are to be conducted as part of a Space Station-based Technology Development Mission for the growth phase of Space Station construction and operation. The experiments are: (1) an investigation of the flame-spread rate and combustion-product evolution in the burning of typical spacecraft materials in low gravity; (2) an evaluation of the interaction of fires and candidate fire extinguishers in low gravity; and (3) an investigation of the persistence and propagation of smoldering and deep-seated combustion in low gravity.

  16. Modeling heat and moisture transport in firefighter protective clothing during flash fire exposure

    NASA Astrophysics Data System (ADS)

    Chitrphiromsri, Patirop; Kuznetsov, Andrey V.

    2005-01-01

    In this paper, a model of heat and moisture transport in firefighter protective clothing during a flash fire exposure is presented. The aim of this study is to investigate the effect of coupled heat and moisture transport on the protective performance of the garment. Computational results show the distribution of temperature and moisture content in the fabric during the exposure to the flash fire as well as during the cool-down period. Moreover, the duration of the exposure during which the garment protects the firefighter from getting second and third degree burns from the flash fire exposure is numerically predicted. A complete model for the fire-fabric-air gap-skin system is presented.

  17. 33 CFR 149.419 - Can the water supply for the helicopter deck fire protection system be part of a fire water system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Can the water supply for the... § 149.419 Can the water supply for the helicopter deck fire protection system be part of a fire water system? (a) The water supply for the helicopter deck fire protection system required under § 149.420 or...

  18. Teaching safety at a summer camp: evaluation of a fire safety curriculum in an urban community setting.

    PubMed

    Chavez, Audrie A; Duzinski, Sarah V; Wheeler, Tareka C; Lawson, Karla A

    2014-09-01

    To evaluate the effectiveness of the Danger Rangers Fire Safety Curriculum in increasing the fire safety knowledge of low-income, minority children in an urban community setting. Data was collected from child participants via teacher/researcher administered pre-, post-, and retention tests. A self-administered questionnaire was collected from parents pre- and post-intervention to assess fire/burn prevention practices. Paired t-tests were conducted to compare pre-, post-, and retention test mean scores by grade group. McNemar's test was used to determine if there was a change in parent-reported prevention practices following the intervention. The first/second grade group and the third grade group scored significantly higher on the post- and retention test as compared to the pre-test (p<0.0001 for all comparisons). There was no significant change in scores for the pre-k/k group after the intervention. There was a significant increase in 2 of 4 parent-reported fire/burn-related prevention practices after the intervention. Fire safety knowledge improved among first to third grade children, but not among pre-kinder and kindergarten children who participated in the intervention. This study also showed that a program targeted towards children and delivered in a classroom setting has the potential to influence familial prevention practices by proxy. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  19. Management impacts on fire occurrence: A comparison of fire regimes of African and South American tropical savannas in different protected areas.

    PubMed

    Alvarado, Swanni T; Silva, Thiago Sanna Freire; Archibald, Sally

    2018-07-15

    Humans can alter fire dynamics in grassland systems by changing fire frequency, fire seasonality and fuel conditions. These changes have effects on vegetation structure and recovery, species composition, and ecosystem function. Understanding how human management can affect fire regimes is vital to detect potential changes in the resilience of plant communities, and to predict vegetation responses to human interventions. We evaluated the fire regimes of two recently protected areas in Madagascar (Ibity and Itremo NPA) and one in Brazil (Serra do Cipó NP) before and after livestock exclusion and fire suppression policies. We compare the pre- and post-management fire history in these areas and analyze differences in terms of total annual burned area, density of ignitions, burn scar size distribution, fire return period and seasonal fire distribution. More than 90% of total park areas were burned at least once during the studied period, for all parks. We observed a significant reduction in the number of ignitions for Ibity NPA and Serra do Cipó NP after livestock exclusion and active fire suppression, but no significant change in total burned area for each protected area. We also observed a seasonal shift in burning, with fires happening later in the fire season (October-November) after management intervention. However, the protected areas in Madagascar had shorter fire return intervals (3.23 and 1.82 years) than those in Brazil (7.91 years). Our results demonstrate that fire exclusion is unattainable, and probably unwarranted in tropical grassland conservation areas, but show how human intervention in fire and vegetation patterns can alter various aspects of the fire regimes. This information can help with formulating realistic and effective fire management policies in these valuable conservation areas. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. 76 FR 3178 - Fire Protection in Shipyard Employment Standard; Extension of the Office of Management and Budget...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-19

    ... (paperwork) requirements. In general, the Standard requires employers to develop a written fire safety plan... of the details of the fire safety plan and that employees have been trained as required by the... to post the fire safety plan or to place it in an area accessible to employees to 12 hours for firms...

  1. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The following waters of Fire Island Inlet are a safety zone: Beginning at a point on shore at 40°37.523′ N, 073... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Coast Guard Station Fire Island...

  2. Fire Safety Tests for Cesium-Loaded Spherical Resorcinol Formaldehyde Resin: Data Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dong-Sang; Schweiger, Michael J.; Peterson, Reid A.

    2012-09-01

    A draft safety evaluation of the scenario for spherical resorcinol formaldehyde (SRF) resin fire inside the ion exchange column was performed by the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Fire Safety organization. The result of this draft evaluation suggested a potential change of the fire safety classification for the Cesium Ion Exchange Process System (CXP) emergency elution vessels, equipment, and piping. To resolve this question, the fire properties of the SRF resin were measured by Southwest Research Institute (SwRI) through a subcontract managed by Pacific Northwest National Laboratory (PNNL). The results of initial fire safety tests on themore » SRF resin were documented in a previous report (WTP-RPT-218). The present report summarizes the results of additional tests performed by SwRI on the cesium-loaded SRF resin. The efforts by PNNL were limited to summarizing the test results provided by SwRI into one consolidated data report. The as-received SwRI report is attached to this report in the Appendix A. Where applicable, the precision and bias of each test method, as given by each American Society for Testing and Materials (ASTM) standard procedure, are included and compared with the SwRI test results of the cesium-loaded SRF resin.« less

  3. 14 CFR 25.1713 - Fire protection: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Electrical Wiring Interconnection Systems (EWIS) § 25.1713... used during emergency procedures must be fire resistant. (c) Insulation on electrical wire and electrical cable, and materials used to provide additional protection for the wire and cable, installed in...

  4. Safety. Fire Service Certification Series. Unit FSCS-FF-2-80.

    ERIC Educational Resources Information Center

    Pribyl, Paul F.

    This training unit on safety is part of a 17-unit course package written to aid instructors in the development, teaching, and evaluation of fire fighters in the Wisconsin Fire Service Certification Series. The purpose stated for the 4-hour unit is to assist firefighters in understanding the hazards of their profession and some methods of reducing…

  5. Health and safety plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-03-24

    This health and safety plan sets forth the requirements and procedures to protect the personnel involved in the removal action project at the former YS-860 Firing Ranges. This project will be conducted in a manner that ensures the protection of the safety and health of workers, the public, and the environment. The purpose of this removal action is to address lead-contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within the watershed. Themore » project will accomplish this through the removal of lead-contaminated soil in the target areas of the two small arms firing ranges. The primary hazards include temperature extremes, equipment operation, noise, potential lead exposure, uneven and slippery working surfaces, and insects.« less

  6. Fire Safety During the Holiday Season | Poster

    Cancer.gov

    Winter is here, and that means holiday decorations, a warm hearth, and (hopefully) plenty of homecooked meals. Unfortunately, winter also brings numerous fire hazards both at work and around the house. This year, as you shop, decorate, and celebrate, keep these safety tips in mind to ensure a safe and enjoyable holiday season.

  7. Review of BART "C" Car Fire Safety Characteristics

    DOT National Transportation Integrated Search

    1987-09-01

    The report presents the results of a review of the fire safety characteristics of the prototype BART "C" Car. Initiated in response to a request from the Urban Mass Transportation Administration (UMTA) Region IX Administrator, the review has been str...

  8. 36 CFR § 1234.12 - What are the fire safety requirements that apply to records storage facilities?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...

  9. Fire safety design considerations for advanced space vehicles

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The desire to understand and explore space has driven man to overcome the confines of the Earth's atmosphere and accept the challenge of spaceflight. With our increasing ability to travel, work, and explore in space comes a need for a better understanding of the hazards in this relatively new endeavor. One of the most important and immediate needs is to be able to predict the ignition, spread, and growth of fire on board spacecraft. Fire safety aboard spacecraft has always been a concern; however, with the increasing number and duration of proposed missions, it is imperative that the spacecraft be designed with a solid understanding of fire hazards, insuring that all risks have been minimized and extinguishment systems are available.

  10. 46 CFR 194.15-7 - Fire protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 194.15-7 Section 194.15-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...

  11. 46 CFR 194.15-7 - Fire protection.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Fire protection. 194.15-7 Section 194.15-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemistry Laboratory and Scientific Laboratory...

  12. Health and safety plan for the removal action at the former YS-860 Firing Ranges, Oak Ridge Y-12 Plant, Oak Ridge, Tennessee

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-04-28

    This health and safety plan sets forth the requirements and procedures to protect the personnel involved in the Lead Source Removal Project at the Former YS-86O Firing Ranges. This project will be conducted in a manner that ensures the protection of the safety and health of workers, the public, and the environment. The purpose of this removal action is to address lead contaminated soil and reduce a potential risk to human health and the environment. This site is an operable unit within the Upper East Fork Poplar Creek watershed. The removal action will contribute to early source actions within themore » watershed. The project will accomplish this through the removal of lead-contaminated soil in the target areas of the two small arms firing ranges. This plan covers the removal actions at the Former YS-86O Firing Ranges. These actions involve the excavation of lead-contaminated soils, the removal of the concrete trench and macadam (asphalt) paths, verification/confirmation sampling, grading and revegetation. The primary hazards include temperature extremes, equipment operation, noise, potential lead exposure, uneven and slippery working surfaces, and insects.« less

  13. Laboratory investigation of fire protection coatings for creosote-treated timber railroad bridges

    Treesearch

    Carol A. Clausen; Robert H. White; James P. Wacker; Stan T. Lebow; Mark A. Dietenberger; Samuel L. Zelinka; Nicole M. Stark

    2014-01-01

    As the incidence of timber railroad bridge fires increases, so has the need to develop protective measures to reduce the risk from accidental ignitions primarily caused by hot metal objects. Of the six barrier treatments evaluated in the laboratory for their ability to protect timbers from fires sourced with ignition from hot metal objects only one intumescent coating...

  14. Safety engineering in handling fuels and lubricants in civil aviation

    NASA Astrophysics Data System (ADS)

    Protoereiskii, Aleksandr Stepanovich

    The book is concerned with methods of improving working conditions, work hygiene, safety engineering, and fire and explosion prevention during the storage and handling of petroleum products at fuel and lubricant storage facilities. The discussion covers methods of protection against static and atmospheric discharges, lightning protection, safety engineering in fuel and lubricant laboratories, and methods of fire prevention and fire extinction. Attention is also given to methods for administering first aid in case of accidents and poisoning.

  15. Using modeling and rehearsal to teach fire safety to children with autism.

    PubMed

    Garcia, David; Dukes, Charles; Brady, Michael P; Scott, Jack; Wilson, Cynthia L

    2016-09-01

    We evaluated the efficacy of an instructional procedure to teach young children with autism to evacuate settings and notify an adult during a fire alarm. A multiple baseline design across children showed that an intervention that included modeling, rehearsal, and praise was effective in teaching fire safety skills. Safety skills generalized to novel settings and maintained during a 5-week follow-up in both training and generalization settings. © 2016 Society for the Experimental Analysis of Behavior.

  16. Foam composite structures. [for fire retardant airframe materials

    NASA Technical Reports Server (NTRS)

    Delano, C. B.; Milligan, R. J.

    1976-01-01

    The need to include fire resistant foams into state of the art aircraft interior paneling to increase passenger safety in aircraft fires was studied. Present efforts were directed toward mechanical and fire testing of panels with foam inclusions. Skinned foam filled honeycomb and PBI structural foams were the two constructions investigated with attention being directed toward weight/performance/cost trade-off. All of the new panels demonstrated improved performance in fire and some were lighter weight but not as strong as the presently used paneling. Continued efforts should result in improved paneling for passenger safety. In particular the simple partial filling (fire side) of state-of-the-art honeycomb with fire resistant foams with little sacrifice in weight would result in panels with increased fire resistance. More important may be the retarded rate of toxic gas evolution in the fire due to the protection of the honeycomb by the foam.

  17. 2017 Fire Protection Informational Exchange Meeting

    DTIC Science & Technology

    documents the results of an information exchange meeting held May 1011, 2017 at the US Army Research Laboratory, which brought together interested...parties across the armed services to outline, as a community, the current state of the art in fire protection research and engineering and determine...where future efforts would be most advantageous. The forum provided the opportunity to strengthen old collaborations, begin new partnerships, and serve

  18. Progress in Fire Detection and Suppression Technology for Future Space Missions

    NASA Technical Reports Server (NTRS)

    Friedman, Robert; Urban, David L.

    2000-01-01

    Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.

  19. Effects of fire fighter protective ensembles on mobility and performance.

    PubMed

    Coca, Aitor; Williams, W Jon; Roberge, Raymond J; Powell, Jeffrey B

    2010-07-01

    Many studies have shown that fire fighter turnout gear and equipment may restrict mobility. The restriction of movement is usually due to a decrease in range of motion (ROM). It is important to know how much the decrease in ROM affects performance. The aim of this study was to determine the effects of fire fighter protective ensembles on mobility and performance by measuring static and dynamic range of motion (ROM) and job-related tasks. Eight healthy adults (5 males, 3 females), aged 20-40 years, participated in this study. The study consisted of measuring a battery of motions and fire fighter specific tasks while wearing a standard fire fighter ensemble (SE) or regular light clothing (baseline or BL). Several BL ROM tests were significantly (p < 0.05) different from the SE test, including a decrease in shoulder flexion, cervical rotation and flexion, trunk lateral flexion, and stand and reach. There was a significant decrease in time from SE to baseline performing the one-arm search task and object lift. These overall findings support the need for a comprehensive ergonomic evaluation of protective clothing systems to ascertain human factors issues. The development of a Standard Ergonomics Test Practice for further use in laboratories that conduct personal protective systems evaluations using human test subjects is recommended. Published by Elsevier Ltd.

  20. Fire safety experiments on MIR Orbital Station

    NASA Technical Reports Server (NTRS)

    Egorov, S. D.; Belayev, A. YU.; Klimin, L. P.; Voiteshonok, V. S.; Ivanov, A. V.; Semenov, A. V.; Zaitsev, E. N.; Balashov, E. V.; Andreeva, T. V.

    1995-01-01

    The process of heterogeneous combustion of most materials under zero-g without forced motion of air is practically impossible. However, ventilation is required to support astronauts' life and cool equipment. The presence of ventilation flows in station compartments at accidental ignition can cause a fire. An additional, but exceedingly important parameter of the fire risk of solid materials under zero-g is the minimum air gas velocity at which the extinction of materials occurs. Therefore, the conception of fire safety can be based on temporarily lowering the intensity of ventilation and even turning it off. The information on the limiting conditions of combustion under natural conditions is needed from both scientific and practical points of view. It will enable us to judge the reliability of results of ground-based investigations and develop a conception of fire safety of inhabited sealed compartments of space stations to by provided be means of nontraditional and highly-effective methods without both employing large quantities of fire-extinguishing compounds and hard restrictions on use of polymers. In this connection, an experimental installation was created to study the process of heterogeneous combustion of solid non-metals and to determine the conditions of its extinction under microgravity. This installation was delivered to the orbital station 'Mir' and the cosmonauts Viktorenko and Kondakova performed initial experiments on it in late 1994. The experimental installation consists of a combustion chamber with an electrical systems for ignition of samples, a device for cleaning air from combustion products, an air suction unit, air pipes and a control panel. The whole experiment is controlled by telemetry and recorded with two video cameras located at two different places. Besides the picture, parameters are recorded to determine the velocity of the air flow incoming to the samples, the time points of switching on/off the devices, etc. The combustion chamber

  1. Fire Prevention and Emergency Procedures. Module SH-05. Safety and Health.

    ERIC Educational Resources Information Center

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on fire prevention and emergency procedures is one of 50 modules concerned with job safety and health. This module discusses the chemistry of fire and the methods for extinguishment, along with the steps necessary for emergency action. Following the introduction, 10 objectives (each keyed to a page in the text) the student is…

  2. Fire and Life Safety Training Needs of Rail Rapid Transit System and Fire Service Personnel

    DOT National Transportation Integrated Search

    1983-05-01

    This report presents a summary and the results of the successful workshop "On Track to Fire and Life Safety in Rail Rapid Transit," held on August 2-4, 1982, at Crystal City, Virginia. Sponsored by the Urban Mass Transportation Administration (UMTA) ...

  3. Vocabulary of aerospace safety terms pertaining to cryogenic safety, fires, explosions, and structure failure

    NASA Technical Reports Server (NTRS)

    Pelouch, J. J., Jr.; Mandel, G.; Ordin, P. M.

    1976-01-01

    This vocabulary listing characterizes the contents of over 10,000 documents of the NASA Aerospace Safety Research and Data Institute's (ASRDI) safety engineering collection. The ASRDI collection is now one of the series accessible on the NASA RECON data base. There are approximately 6,300 postable terms that describe literature in the areas of cryogenic fluid safety, specifically hydrogen, oxygen, liquified natural gas; fire and explosion technology; and the mechanics of structural failure. To facilitate the proper selection of information nonpostable, related and array terms have been included in this listing.

  4. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...

  5. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are the structural fire protection requirements for accommodation spaces and modules? (a) Accommodation...

  6. Fire Safety Fundamentals

    ERIC Educational Resources Information Center

    Roy, Ken

    2004-01-01

    Planning and prevention is the best defense against fires in school. This is particularly true in the science laboratory due to the presence of flammable gases, liquids, combustibles, and other potential sources of fire. Teachers can prevent fires from starting by maintaining prudent lab practices when dealing with combustible and flammable…

  7. Fire Safety Training with Adults Who Are Profoundly Mentally Retarded.

    ERIC Educational Resources Information Center

    Rae, Rosamond; Roll, David

    1985-01-01

    An intensive fire safety training program for profoundly mentally retarded institutionalized persons resulted in a significant decrease in mean evacuation time and gradual substitution of verbal for physical prompts. (CL)

  8. 49 CFR 192.171 - Compressor stations: Additional safety equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Compressor stations: Additional safety equipment... Pipeline Components § 192.171 Compressor stations: Additional safety equipment. (a) Each compressor station must have adequate fire protection facilities. If fire pumps are a part of these facilities, their...

  9. Risk Based Reliability Centered Maintenance of DOD Fire Protection Systems

    DTIC Science & Technology

    1999-01-01

    2.2.3 Failure Mode and Effect Analysis ( FMEA )............................ 2.2.4 Failure Mode Risk Characterization...Step 2 - System functions and functional failures definition Step 3 - Failure mode and effect analysis ( FMEA ) Step 4 - Failure mode risk...system). The Interface Location column identifies the location where the FMEA of the fire protection system began or stopped. For example, for the fire

  10. Monitoring of fire incidences in vegetation types and Protected Areas of India: Implications on carbon emissions

    NASA Astrophysics Data System (ADS)

    Reddy, C. Sudhakar; Padma Alekhya, V. V. L.; Saranya, K. R. L.; Athira, K.; Jha, C. S.; Diwakar, P. G.; Dadhwal, V. K.

    2017-02-01

    Carbon emissions released from forest fires have been identified as an environmental issue in the context of global warming. This study provides data on spatial and temporal patterns of fire incidences, burnt area and carbon emissions covering natural vegetation types (forest, scrub and grassland) and Protected Areas of India. The total area affected by fire in the forest, scrub and grasslands have been estimated as 48765.45, 6540.97 and 1821.33 km 2, respectively, in 2014 using Resourcesat-2 AWiFS data. The total CO 2 emissions from fires of these vegetation types in India were estimated to be 98.11 Tg during 2014. The highest emissions were caused by dry deciduous forests, followed by moist deciduous forests. The fire season typically occurs in February, March, April and May in different parts of India. Monthly CO 2 emissions from fires for different vegetation types have been calculated for February, March, April and May and estimated as 2.26, 33.53, 32.15 and 30.17 Tg, respectively. Protected Areas represent 11.46% of the total natural vegetation cover of India. Analysis of fire occurrences over a 10-year period with two types of sensor data, i.e., AWiFS and MODIS, have found fires in 281 (out of 614) Protected Areas of India. About 16.78 Tg of CO 2 emissions were estimated in Protected Areas in 2014. The natural vegetation types of Protected Areas have contributed for burnt area of 17.3% and CO 2 emissions of 17.1% as compared to total natural vegetation burnt area and emissions in India in 2014. 9.4% of the total vegetation in the Protected Areas was burnt in 2014. Our results suggest that Protected Areas have to be considered for strict fire management as an effective strategy for mitigating climate change and biodiversity conservation.

  11. Key Problems of Fire Safety Enforcement in Traffic and Communication Centers (TCC)

    NASA Astrophysics Data System (ADS)

    Medyanik, M.; Zosimova, O.

    2017-10-01

    A Traffic and Communication Center (TCC) means facilities designed and used to distribute and redirect flows of humans and motor vehicles while they get serviced and operate. This paper sets forth the basic problems of fire safety enforcement on the TCC, and the causes that slow down human and vehicle traffic speeds. It proposes ways to solve the problems of fire safety enforcement on the TCC, in the Russian Federation and elsewhere. Engineering solutions are proposed for TCC design, with key outlooks of TCC future development as an alternative way to organize access in transportation.

  12. An evaluation of The Great Escape: can an interactive computer game improve young children's fire safety knowledge and behaviors?

    PubMed

    Morrongiello, Barbara A; Schwebel, David C; Bell, Melissa; Stewart, Julia; Davis, Aaron L

    2012-07-01

    Fire is a leading cause of unintentional injury and, although young children are at particularly increased risk, there are very few evidence-based resources available to teach them fire safety knowledge and behaviors. Using a pre-post randomized design, the current study evaluated the effectiveness of a computer game (The Great Escape) for teaching fire safety information to young children (3.5-6 years). Using behavioral enactment procedures, children's knowledge and behaviors related to fire safety were compared to a control group of children before and after receiving the intervention. The results indicated significant improvements in knowledge and fire safety behaviors in the intervention group but not the control. Using computer games can be an effective way to promote young children's understanding of safety and how to react in different hazardous situations.

  13. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...

  14. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...

  15. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under Table 149.409 of this part, each helicopter fueling facility must have a fire protection...

  16. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under Table 149.409 of this part, each helicopter fueling facility must have a fire protection...

  17. 33 CFR 149.418 - What fire protection system must a helicopter fueling facility have?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... a helicopter fueling facility have? 149.418 Section 149.418 Navigation and Navigable Waters COAST... protection system must a helicopter fueling facility have? In addition to the portable fire extinguishers required under table 149.409, each helicopter fueling facility must have a fire protection system complying...

  18. 33 CFR 165.152 - Coast Guard Station Fire Island, Long Island, New York-safety zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Coast Guard Station Fire Island, Long Island, New York-safety zone. 165.152 Section 165.152 Navigation and Navigable Waters COAST GUARD... § 165.152 Coast Guard Station Fire Island, Long Island, New York—safety zone. (a) Location. The...

  19. LSD 36 Well Deck Fire Protection

    DTIC Science & Technology

    1991-05-30

    below, which are loaded with personnel, vehicles and supplies. Normally, an Aqueous Film Forming Foam ( AFFF ) sprinkler system would be recommended for...the foam to the center area and allow the AFFF film to spread out from there; or, some combination of the two approaches. Results Phase I Tests A...landing craft and vehicles stored in the well deck below. Based on these tests, the optimum fire protection system would involve an Aqueous Film

  20. Performance of a Protected Wireless Sensor Network in a Fire. Analysis of Fire Spread and Data Transmission

    PubMed Central

    Antoine-Santoni, Thierry; Santucci, Jean-François; de Gentili, Emmanuelle; Silvani, Xavier; Morandini, Frederic

    2009-01-01

    The paper deals with a Wireless Sensor Network (WSN) as a reliable solution for capturing the kinematics of a fire front spreading over a fuel bed. To provide reliable information in fire studies and support fire fighting strategies, a Wireless Sensor Network must be able to perform three sequential actions: 1) sensing thermal data in the open as the gas temperature; 2) detecting a fire i.e., the spatial position of a flame; 3) tracking the fire spread during its spatial and temporal evolution. One of the great challenges in performing fire front tracking with a WSN is to avoid the destruction of motes by the fire. This paper therefore shows the performance of Wireless Sensor Network when the motes are protected with a thermal insulation dedicated to track a fire spreading across vegetative fuels on a field scale. The resulting experimental WSN is then used in series of wildfire experiments performed in the open in vegetation areas ranging in size from 50 to 1,000 m2. PMID:22454563

  1. Performance of a protected wireless sensor network in a fire. Analysis of fire spread and data transmission.

    PubMed

    Antoine-Santoni, Thierry; Santucci, Jean-François; de Gentili, Emmanuelle; Silvani, Xavier; Morandini, Frederic

    2009-01-01

    The paper deals with a Wireless Sensor Network (WSN) as a reliable solution for capturing the kinematics of a fire front spreading over a fuel bed. To provide reliable information in fire studies and support fire fighting strategies, a Wireless Sensor Network must be able to perform three sequential actions: 1) sensing thermal data in the open as the gas temperature; 2) detecting a fire i.e., the spatial position of a flame; 3) tracking the fire spread during its spatial and temporal evolution. One of the great challenges in performing fire front tracking with a WSN is to avoid the destruction of motes by the fire. This paper therefore shows the performance of Wireless Sensor Network when the motes are protected with a thermal insulation dedicated to track a fire spreading across vegetative fuels on a field scale. The resulting experimental WSN is then used in series of wildfire experiments performed in the open in vegetation areas ranging in size from 50 to 1,000 m(2).

  2. A Combined Water-Bromotrifluoromethane Crash-Fire Protection System for a T-56 Turbopropeller Engine

    NASA Technical Reports Server (NTRS)

    Campbell, John A.; Busch, Arthur M.

    1959-01-01

    A crash-fire protection system is described which will suppress the ignition of crash-spilled fuel that may be ingested by a T-56 turbo-propeller engine. This system includes means for rapidly extinguishing the combustor flame, means for cooling and inerting with water the hot engine parts likely to ignite engine ingested fuel, and means for blanketing with bromotrifluoromethane massive metal parts that may reheat after the engine stops rotating. Combustion-chamber flames were rapidly extinguished at the engine fuel nozzles by a fuel shutoff and drain valve. Hot engine parts were inerted and cooled by 42 pounds of water discharged at seven engine stations. Massive metal parts that could reheat were inerted with 10 pounds of bromotrifluoromethane discharged at two engine stations. Performance trials of the crash-fire protection system were conducted by bringing the engine up to takeoff temperature, actuating the crash-fire protection system, and then spraying fuel into the engine to simulate crash-ingested fuel. No fires occurred during these trials, although fuel was sprayed into the engine from 0.3 second to 15 minutes after actuating the crash-fire protection system.

  3. 49 CFR 192.171 - Compressor stations: Additional safety equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of... must have adequate fire protection facilities. If fire pumps are a part of these facilities, their... event of inadequate cooling or lubrication of the unit. (d) Each compressor station gas engine that...

  4. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false What are the structural fire...: DESIGN, CONSTRUCTION, AND EQUIPMENT Design and Equipment Structural Fire Protection § 149.641 What are...

  5. Motorcoach fire safety analysis : the causes, frequency, and severity of motorcoach fires in the United States

    DOT National Transportation Integrated Search

    2012-06-28

    The Federal Motor Carrier Safety Administrations (FMCSA) mission is to reduce crashes, injuries, and fatalities on our nations roads involving motor vehicles, and to further its work the agency set out to identify ways to reduce motorcoach fire...

  6. Can fire safety in hotels be improved? Results from the survey of a panel of experts in Spain.

    PubMed

    Rubio-Romero, Juan Carlos; Márquez-Sierra, Francisco; Suárez-Cebador, Manuel

    2016-06-08

    The hotel industry is an important driver of the European labour market with over 250,000 hotels employing some 2 million people. In Spain, 240 workers were injured by fires in hotels from 2004 to 2008. Fire is considered to be the most important risk in the hotel industry, but the lack of an EU-wide data recording system for hotels makes it difficult to give exact figures for fire events. We analysed the state of fire prevention systems in hotels in Spain with the aim of proposing strategies to improve fire safety. A 10-item questionnaire was administered from 2007 to 2009 to 15 Spanish experts in fire safety. The questions were measured using a Likert scale and classified into 4 sections: current state of installations, influence of establishment characteristics, application of regulations and priority ranking of actions. Descriptive statistics summarized the data and t-tests evaluated the agreement foreach statement in the questionnaire. The statistical analysis showed homogeneity in the responses by the experts in all four categories: current state of fire safety installations, influence of establishment characteristics, application of regulations, and priority of actions. There was consensus among the experts over the necessity to improve the enforcement of regulations and also regarding the existence of an association between the hotel category (in Spain they are ranked using a 1 to 5 "star" rating system) and the level of fire safety; hotels with a higher category had higher levels of safety. There is a need to identify ways to apply fire safety standards to older hotels so that they comply with new regulations, to standardize regulations for different regions and countries, to improve the maintenance of installations and equipment, to increase the effectiveness of inspections conducted by government bodies, and to raise the general awareness of stakeholders involved in hotel fire prevention.

  7. Working toward the elimination of residential fire deaths: the Centers for Disease Control and Prevention's Smoke Alarm Installation and Fire Safety Education (SAIFE) program.

    PubMed

    Ballesteros, Michael F; Jackson, Mark L; Martin, Maurice W

    2005-01-01

    To address residential fires and related injuries, the Centers for Disease Control and Prevention funds state health departments to deliver a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in high-risk homes in 16 states. This program involves recruiting local communities and community partners, hiring a local coordinator, canvassing neighborhood homes, installing long-lasting lithium-powered smoke alarms, and providing general fire safety education and 6-month follow-up to determine alarm functionality. Local fire departments are vital community partners in delivering this program. Since the program's inception, more than 212,000 smoke alarms have been installed in more than 126,000 high-risk homes. Additionally, approximately 610 lives have potentially been saved as a result of a program alarm that provided early warning to a dangerous fire incident.

  8. Airport Fire and Rescue Personnel Protective Clothing

    DOT National Transportation Integrated Search

    1995-07-13

    This advisory circular (AC) identifies minimum standards for design, performance, : testing, and safety of personnel protective equipment (PPE), frequently referred : to as personnel protective clothing for airport firefighting. This AC also : assist...

  9. Fire safety knowledge and practices among residents of an assisted living facility.

    PubMed

    Jaslow, David; Ufberg, Jacob; Yoon, Russell; McQueen, Clay; Zecher, Derek; Jakubowski, Greg

    2005-01-01

    Assisted living facilities (ALFs) pose unique fire risks to the elderly that may be linked to specific fire safety (FS) practices. To evaluate self-reported FS practices among ALF residents. All residents of a small ALF were surveyed regarding actual and hypothetical FS behaviors, self-perceived fire risk, and FS preparedness. Fifty-eight ALF residents completed the survey. Thirty-three (58%) individuals reported one or more disabilities. Seven (12%) residents ignored the fire alarm and 21 (35%) could not hear it clearly. Sixteen (28%) residents would attempt to locate the source of a fire rather than escape from the building. Only 24 (42%) residents were familiar with the building fire plan. Twenty-three (40%) people surveyed believed that they were not at risk of fire in the study facility. Residents of an ALF may be at increased fire injury risk due to their FS practices and disabilities.

  10. Linking management effectiveness indicators to observed effects of protected areas on fire occurrence in the Amazon rainforest.

    PubMed

    Nolte, Christoph; Agrawal, Arun

    2013-02-01

    Management-effectiveness scores are used widely by donors and implementers of conservation projects to prioritize, track, and evaluate investments in protected areas. However, there is little evidence that these scores actually reflect the capacity of protected areas to deliver conservation outcomes. We examined the relation between indicators of management effectiveness in protected areas and the effectiveness of protected areas in reducing fire occurrence in the Amazon rainforest. We used data collected with the Management Effectiveness Tracking Tool (METT) scorecard, adopted by some of the world's largest conservation organizations to track management characteristics believed to be crucial for protected-area effectiveness. We used the occurrence of forest fires from 2000 through 2010 as a measure of the effect of protected areas on undesired land-cover change in the Amazon basin. We used matching to compare the estimated effect of protected areas with low versus high METT scores on fire occurrence. We also estimated effects of individual protected areas on fire occurrence and explored the relation between these effects and METT scores. The relations between METT scores and effects of protected areas on fire occurrence were weak. Protected areas with higher METT scores in 2005 did not seem to have performed better than protected areas with lower METT scores at reducing fire occurrence over the last 10 years. Further research into the relations between management-effectiveness indicators and conservation outcomes in protected areas seems necessary, and our results show that the careful application of matching methods can be a suitable method for that purpose. ©2012 Society for Conservation Biology.

  11. Protection against fire in the mountainous forests of Greece case study: forest complex of W. Nestos

    NASA Astrophysics Data System (ADS)

    Drosos, Vasileios C.; Giannoulas, Vasileios J.; Stergiadou, Anastasia; Karagiannis, Evaggelos; Doukas, Aristotelis-Kosmas G.

    2014-08-01

    Forest fires are an ancient phenomenon. Appear, however, with devastating frequency and intensity over the last 30 years. In our country, the climatic conditions in combination with the intense relief, favor their rapid spread. Considering the fact that environmental conditions provided for decades even worse (increased temperature, drought and vegetation), then the problem of forest fires in our country, is expected to become more intense. The work focuses on the optimization model of the opening up of the forest mountain areas taking into account the prevention and suppression of forest fires. Research area is the mountain forest complex of W. Nestos of Drama Prefecture. The percentage of forest protection area is examined under the light whether the total hose length corresponds to the actual operational capacity to reach a fire source. For this reason are decided to present a three case study concerning area of the forest being protected by fire extinguishing vehicles. The first one corresponds to a fire suppression bandwidth (buffer zone) with a capacity radius of 150m uphill and 250m downhill from the origin point where the fire extinguishing vehicle stands. The second one corresponds to a fire suppression capacity of 200m uphill and 400m downhill and the third one corresponds to a fire suppression capacity of 300m uphill and 500m downhill. The most important forest technical infrastructures to prevent fire are roads network (opening up) for fire protection and buffer zones. Patrols of small and agile 4 × 4 appropriately equipped (pipe length of 500 meters and putting pressure on uphill to 300 meters) for the first attack of the fire in the summer months coupled with early warning of fire observatories adequately cover the forest protection of W. Nestos complex. But spatial distribution needed improvements to a road density of the optimum economic Dec, both forest protection and for better management (skidding) of woody capital.

  12. Resistance after firing protected electric match. [Patent application

    DOEpatents

    Montoya, A.P.

    1980-03-20

    An electric match having electrical leads embedded in flame-producing compound is protected against an accidental resistance across the leads after firing by a length of heat-shrinkable tubing encircling the match body and having a skirt portion extending beyond the leads. The heat of the burning match and an adjacent thermal battery causes the tubing to fold over the end of the match body, covering the ends of the leads and protecting them from molten pieces of the battery.

  13. Passive fire protection in high density village (case study, Bustaman Semarang)

    NASA Astrophysics Data System (ADS)

    Sukawi, Sukawi; Wahyu Firmandhani, Satriya; Hardiman, Gagoek

    2017-12-01

    Fire hazard is the disaster that always has an unpredictable process of coming. When it comes, its level scope and the magnitude of the effects cannot be predicted. Dense settlements especially in big cities, among others Bustaman Kampong Semarang never escape from physical problems such as flooding and wildfire. If both are compared in dense settlements scope, so that, wild fire is the most potentially catastrophic. It is necessary to do a research on passive fire protection in a village of high density city such as Bustaman. Qualitative research was conducted using descriptive method to conduct observations and interviews in the Bustaman. Bustaman as a high density village, with narrow roads and dense rows of houses. The terraced buildings are also encountered, and found many buildings use combustible material. That environmental conditions can facilitate the propagation of flames in case of fire. To improve the established Bustaman's environment, in terms of the application of passive fire protection systems, it is recommended to utilize the road as the dividing buildings. Need to build the separation wall fireproof in every each series in several units of too long buildings and attempted open space procurement that separates rows of buildings that are too long, and also the replacement of combustible material with a material that is more incombustible.

  14. Ignorance and Hazards in Academe: The Dilemma of Fire Safety in American Higher Education.

    ERIC Educational Resources Information Center

    Crnkovich, John J.; Dye, Charles M.

    An examination was made of five major campus fires between 1971 and 1983 in an attempt to better understand the fire hazards associated with the operation of a modern U.S. college or university campus. Overall research revealed a general lack of interest in campus fire safety by colleges and universities in the United States and Canada. Analysis…

  15. The development of the residential Fire H.E.L.P. tool kit: a resource to protect homebound older adults.

    PubMed

    Diekman, Shane; Huitric, Michele; Netterville, Linda

    2010-01-01

    This article describes the development of the Fire H.E.L.P. tool kit for training selected Meals On Wheels (MOW) staff in Texas to implement a fire safety program for homebound older adults. We used a formative evaluation approach during the tool kit's development, testing, and initial implementation stages. The tool kit includes instructional curricula on how to implement Fire H.E.L.P., a home assessment tool to determine a residence's smoke alarm needs, and fire safety educational materials. During the tool kit's pilot test, MOW participants showed enhanced fire safety knowledge and high levels of confidence about applying their newfound training skills. After the pilot test, MOW staff used the tool kit to conduct local training sessions, provide fire safety education, and install smoke alarms in the homes of older adults. We believe the approach used to develop this tool kit can be applied to education efforts for other, related healthy home topics.

  16. Synthesis and evaluation of borates derived from boric acid for fire and decay protections

    Treesearch

    George Chen

    1999-01-01

    The degradation of wood by decay, fire and UV constitutes the three major losses of wood products in use. Commercial wood preservatives including chromated copper arsenate(CCA) and pentachlorophenol(penta) can only protect wood from decay. Dual protections of wood against decay and fire or decay and UV if acheivable are more desirable. Many phosphorus and boron...

  17. Occupational Safety and Health Professionals

    ERIC Educational Resources Information Center

    Wash, Pat

    1975-01-01

    The growing concern for safety in both the workplace and in consumer products will create many new jobs through the mid-1980's--especially in private industry. The largest number of safety professionals are safety engineers; others include fire protection engineers, industrial hygienists, loss control and occupational health consultants, and…

  18. The performance of lightweight plastic foams developed for fire safety

    NASA Technical Reports Server (NTRS)

    Fish, R. H.

    1971-01-01

    The use of a low density, polyurethane based foam to suppress a fire and to provide protection for the structure of an aircraft or spacecraft is discussed. The mechanism by which foams provide protection from heat and create a nonflammable surface is described. Various materials and their application to specific types of structures are examined.

  19. 14 CFR 25.1723 - Flammable fluid fire protection: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Flammable fluid fire protection: EWIS. 25.1723 Section 25.1723 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Electrical Wiring Interconnection...

  20. National Fire Protection Association

    MedlinePlus

    ... closed NFPA Journal® NFPA Journal® Update (newsletter) Fire Technology ... die from American home fires, and another 13,000 are injured each year. This is the story of fire that the statistics won't show ...

  1. Fire-protection research for energy technology: Fy 80 year end report

    NASA Astrophysics Data System (ADS)

    Hasegawa, H. K.; Alvares, N. J.; Lipska, A. E.; Ford, H.; Priante, S.; Beason, D. G.

    1981-05-01

    This continuing research program was initiated in order to advance fire protection strategies for Fusion Energy Experiments (FEE). The program expanded to encompass other forms of energy research. Accomplishments for fiscal year 1980 were: finalization of the fault-free analysis of the Shiva fire management system; development of a second-generation, fire-growth analysis using an alternate model and new LLNL combustion dynamics data; improvements of techniques for chemical smoke aerosol analysis; development and test of a simple method to assess the corrosive potential of smoke aerosols; development of an initial aerosol dilution system; completion of primary small-scale tests for measurements of the dynamics of cable fires; finalization of primary survey format for non-LLNL energy technology facilities; and studies of fire dynamics and aerosol production from electrical insulation and computer tape cassettes.

  2. Responsible for Fire Safety. Seventh Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the seventh grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of seventh grade students, its objectives include: (1) practicing responsible decision-making regarding fire and burn hazards, including peer pressure related to fire risks; and (2) practicing…

  3. In situ thermal condensation of glucose-diammonium phosphate in wood for fire and fungal decay protection

    Treesearch

    George Chen

    2009-01-01

    Thermal condensation of glucose-diammonium phosphate in wood at 160 and 190[degrees]C will protect wood against fire and decay in one treatment using an aqueous system. For fire protection, treatments at 160 or 190[degrees]C led to low flammability as evidenced by fire-tube tests. For nonleached wood, weight losses were 1.9, 2.0, and 2.0% with chemical retentions of 56...

  4. Occupancy Fire Record. Libraries.

    ERIC Educational Resources Information Center

    National Fire Protection Association, Boston, MA.

    Considerations essential to adequate protection for library facilities have been assembled in the form of recommendations and related to specific examples. Five steps are given which outline the procedures to follow in order to achieve fire safety. With regard to planning, six considerations are dealt with in detail--(1) the saving of lives, (2)…

  5. Fire Safety's My Job. Eighth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the eighth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of eighth grade students, its objectives include: (1) focusing on technical aspects of fire hazards and detection, and (2) exploring fire hazards outside the home. Texas essential elements of…

  6. 5 CFR 551.215 - Fire protection activities and 7(k) coverage for FLSA pay and exemption determinations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...

  7. 5 CFR 551.215 - Fire protection activities and 7(k) coverage for FLSA pay and exemption determinations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...

  8. 5 CFR 551.215 - Fire protection activities and 7(k) coverage for FLSA pay and exemption determinations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... similar employees involved in fire protection research or in the design and development of fire protection... Protection and Prevention series, including any qualified firefighter who is assigned to perform support... considerations; (ii) Employees in positions properly classified in other series, such as Forestry Technician, for...

  9. 75 FR 17644 - Update to NFPA 101, Life Safety Code, for State Home Facilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... DEPARTMENT OF VETERANS AFFAIRS 38 CFR Part 51 RIN 2900-AN59 Update to NFPA 101, Life Safety Code... certain provisions of the 2009 edition of the National Fire Protection Association's NFPA 101, Life Safety... standards regarding life safety and fire safety. DATES: Written comments must be received by VA on or before...

  10. Improved fire resistant radio frequency anechoic materials

    NASA Technical Reports Server (NTRS)

    Robinson, D. A.

    1969-01-01

    Protective, flameproof foam covering improves the resistance to fire and surface contamination of low-cost radio frequency absorbing and shielding anechoic materials. This promotes safety of operating personnel and equipment being tested in an otherwise combustible anechoic chamber.

  11. Fire safety at home

    MedlinePlus

    ... over the smoke alarm as needed. Using a fire extinguisher can put out a small fire to keep it from getting out of control. Tips for use include: Keep fire extinguishers in handy locations, at least one on ...

  12. Test results: Halon 1301 versus water sprinkler fire protection for essential electronic equipment

    NASA Astrophysics Data System (ADS)

    Reichelt, E. F.; Walker, J. L.; Vickers, R. N.; Kwan, A. J.

    1982-07-01

    This report describes results of testing two contending extinguishants, Halon 1301 and water, for fire protection of essential electronic equipment. A series of controlled fires in a facility housing an operational electronic data processing system sought to establish immediate and long term effects of exposure of sensitive electronic equipment and stored data to fire extinguishment atmospheres. Test results lead to the conclusion that Halon 1301 is superior to water as an extinguishant for fires occurring in essential electronic equipment installations.

  13. Technology Development for Fire Safety in Exploration Spacecraft and Habitats

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2007-01-01

    Fire during an exploration mission far from Earth is a particularly critical risk for exploration vehicles and habitats. The Fire Prevention, Detection, and Suppression (FPDS) project is part of the Exploration Technology Development Program (ETDP) and has the goal to enhance crew health and safety on exploration missions by reducing the likelihood of a fire, or, if one does occur, minimizing the risk to the mission, crew, or system. Within the past year, the FPDS project has been formalized within the ETDP structure and has seen significant progress on its tasks in fire prevention, detection, and suppression. As requirements for Constellation vehicles and, specifically, the CEV have developed, the need for the FPDS technologies has become more apparent and we continue to make strides to infuse them into the Constellation architecture. This paper describes the current structure of the project within the ETDP and summarizes the significant programmatic activities. Major technical accomplishments are identified as are activities planned for FY07.

  14. Technology Development for Fire Safety in Exploration Spacecraft and Habitats

    NASA Technical Reports Server (NTRS)

    Ruff, Gary A.; Urban, David L.

    2006-01-01

    Fire during an exploration mission far from Earth is a particularly critical risk for exploration vehicles and habitats. The Fire Prevention, Detection, and Suppression (FPDS) project is part of the Exploration Technology Development Program (ETDP) and has the goal to enhance crew health and safety on exploration missions by reducing the likelihood of a fire, or, if one does occur, minimizing the risk to the mission, crew, or system. Within the past year, the FPDS project has been formalized within the ETDP structure and has seen significant progress on its tasks in fire prevention, detection, and suppression. As requirements for Constellation vehicles and, specifically, the CEV have developed, the need for the FPDS technologies has become more apparent and we continue to make strides to infuse them into the Constellation architecture. This paper describes the current structure of the project within the ETDP and summarizes the significant programmatic activities. Major technical accomplishments are identified as are activities planned for FY07.

  15. 77 FR 74381 - Protection of Stratospheric Ozone: Listing of Substitutes for Ozone Depleting Substances-Fire...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-14

    ... Protection of Stratospheric Ozone: Listing of Substitutes for Ozone Depleting Substances--Fire Suppression... a companion proposed rule issuing listings for three fire suppressants under EPA's Significant New... companion proposed rule issuing listings for three fire suppressants under EPA's Significant New...

  16. 76 FR 22383 - National Fire Codes: Request for Proposals for Revision of Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-21

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology National Fire Codes: Request... publishing this notice on behalf of the National Fire Protection Association (NFPA) to announce the NFPA's proposal to revise some of its fire safety codes and standards and requests proposals from the public to...

  17. 3 CFR 8432 - Proclamation 8432 of October 2, 2009. Fire Prevention Week, 2009

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Fire Prevention Week is a time to learn about important fire safety issues and empower our communities... in their homes and workplaces. We can greatly reduce these tragedies by taking a few, very simple... of fire, we honor the brave men and women who protect us from it, and we recommit ourselves to its...

  18. Fire Safety Aspects of Polymeric Materials. Volume 6. Aircraft. Civil and Military

    DTIC Science & Technology

    1977-01-01

    resistance of the existing Polyurethane foam- based seating sys- tems be improved through design, construction, and selection of covering materials. 12. A...aircraft interiors under real fire conditions. To provide the data base for developing improved fire safety standards for aircraft, four types of...the determination of immobilizing effect was based on performance in the swimming test, a simple exercise method also favored by Kimmerle to provide

  19. Novel PEPA-functionalized graphene oxide for fire safety enhancement of polypropylene

    PubMed Central

    Xu, Jia You; Liu, Jie; Li, Kai Dan; Tanemura, Sakae

    2015-01-01

    Polypropylene (PP) is a general-purpose plastic, but some applications are constrained by its high flammability. Thus, flame retardant PP is urgently demanded. In this article, intumescent flame retardant PP (IFRPP) composites with enhanced fire safety were prepared using 1-oxo-4-hydroxymethyl-2,6,7-trioxa-1-phosphabicyclo [2.2.2] octane (PEPA) functionalized graphene oxide (PGO) as synergist. The PGO was prepared through a mild chemical reaction by the covalent attachment of a caged-structure organic compound, PEPA, onto GO nanosheets using toluene diisocynate (TDI) as the intermediary agent. The novel PEPA-functionalized graphene oxide not only improves the heat resistance of GO but also converts GO and PEPA from hydrophobic to hydrophilic materials, which leads to even distribution in PP. In our case, 7 wt% addition of PGO as one of the fillers for IFRPP composites significantly reduces its inflammability and fire hazards when compared with PEPA, by the improvement of first release rate peak (PHRR), total heat release, first smoke release rate peak (PSRR) and total smoke release, suggesting its great potential as the IFR synergist in industry. The reason is mainly attributed to the barrier effect of the unburned graphene sheets, which protects by the decomposition products of PEPA and TDI, promotes the formation of graphitized carbon and inhibits the heat and gas release. PMID:27877775

  20. Novel PEPA-functionalized graphene oxide for fire safety enhancement of polypropylene

    NASA Astrophysics Data System (ADS)

    You Xu, Jia; Liu, Jie; Li, Kai Dan; Miao, Lei; Tanemura, Sakae

    2015-04-01

    Polypropylene (PP) is a general-purpose plastic, but some applications are constrained by its high flammability. Thus, flame retardant PP is urgently demanded. In this article, intumescent flame retardant PP (IFRPP) composites with enhanced fire safety were prepared using 1-oxo-4-hydroxymethyl-2,6,7-trioxa-1-phosphabicyclo [2.2.2] octane (PEPA) functionalized graphene oxide (PGO) as synergist. The PGO was prepared through a mild chemical reaction by the covalent attachment of a caged-structure organic compound, PEPA, onto GO nanosheets using toluene diisocynate (TDI) as the intermediary agent. The novel PEPA-functionalized graphene oxide not only improves the heat resistance of GO but also converts GO and PEPA from hydrophobic to hydrophilic materials, which leads to even distribution in PP. In our case, 7 wt% addition of PGO as one of the fillers for IFRPP composites significantly reduces its inflammability and fire hazards when compared with PEPA, by the improvement of first release rate peak (PHRR), total heat release, first smoke release rate peak (PSRR) and total smoke release, suggesting its great potential as the IFR synergist in industry. The reason is mainly attributed to the barrier effect of the unburned graphene sheets, which protects by the decomposition products of PEPA and TDI, promotes the formation of graphitized carbon and inhibits the heat and gas release.

  1. 14 CFR 125.175 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Protection of other airplane components... CERTIFICATION AND OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD... Requirements § 125.175 Protection of other airplane components against fire. (a) Except as provided in...

  2. 14 CFR 121.277 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Protection of other airplane components....277 Protection of other airplane components against fire. (a) Except as provided in paragraph (b) of this section, all airplane surfaces aft of the nacelles in the area of one nacelle diameter on both...

  3. 14 CFR 125.175 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Protection of other airplane components... CERTIFICATION AND OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD... Requirements § 125.175 Protection of other airplane components against fire. (a) Except as provided in...

  4. 14 CFR 121.277 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Protection of other airplane components....277 Protection of other airplane components against fire. (a) Except as provided in paragraph (b) of this section, all airplane surfaces aft of the nacelles in the area of one nacelle diameter on both...

  5. 14 CFR 125.175 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Protection of other airplane components... CERTIFICATION AND OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD... Requirements § 125.175 Protection of other airplane components against fire. (a) Except as provided in...

  6. 14 CFR 121.277 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Protection of other airplane components....277 Protection of other airplane components against fire. (a) Except as provided in paragraph (b) of this section, all airplane surfaces aft of the nacelles in the area of one nacelle diameter on both...

  7. 14 CFR 121.277 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Protection of other airplane components....277 Protection of other airplane components against fire. (a) Except as provided in paragraph (b) of this section, all airplane surfaces aft of the nacelles in the area of one nacelle diameter on both...

  8. 14 CFR 125.175 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Protection of other airplane components... CERTIFICATION AND OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD... Requirements § 125.175 Protection of other airplane components against fire. (a) Except as provided in...

  9. 14 CFR 125.175 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Protection of other airplane components... CERTIFICATION AND OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD... Requirements § 125.175 Protection of other airplane components against fire. (a) Except as provided in...

  10. 14 CFR 121.277 - Protection of other airplane components against fire.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Protection of other airplane components....277 Protection of other airplane components against fire. (a) Except as provided in paragraph (b) of this section, all airplane surfaces aft of the nacelles in the area of one nacelle diameter on both...

  11. The impact of state fire safe cigarette policies on fire fatalities, injuries, and incidents.

    PubMed

    Folz, David H; Shults, Chris

    Cigarettes are a leading cause of civilian deaths in home fires. Over the last decade, state fire service leaders and allied interest groups succeeded in persuading state lawmakers to require manufacturers to sell only low-ignition strength or "fire safe" cigarettes as a strategy to reduce these fatalities and the injuries and losses that stem from them. This article examines whether the states' fire safe cigarette laws actually helped to save lives, prevent injuries, and reduce the incidence of home fires ignited by cigarettes left unattended by smokers. Controlling for the effects of key demographic, social, economic, and housing variables, this study finds that the states' fire-safe cigarette policies had significant impacts on reducing the rate of smoking-related civilian fire deaths and the incidence of fires started by tobacco products. The findings also suggest that the states' fire safe cigarette policies may have helped to reduce the rate of smoking-related fire injuries. The study shows that collective actions by leaders in the fire service across the states can result in meaningful policy change that protects lives and advances public safety even when a political consensus for action is absent at the national level.

  12. Fire Safety: Stop the Heat. Fourth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the fourth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of fourth grade students, its objectives include: (1) understanding principles of extinguishing fires, (2) investigating issues of peer pressure related to fire setting, (3) developing…

  13. Fire Safety: Protecting Our Children and Families. Hearing before the Select Committee on Children, Youth, and Families. House of Representatives, One Hundred Second Congress, Second Session (August 11, 1992).

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. House Select Committee on Children, Youth, and Families.

    This hearing, chaired by Representative Patricia Schroeder, was held to find ways to reduce the number of deaths and injuries that result from fires. Testimony or prepared statements were given by Representatives Schroeder, Michael Bilirakis, Romano Mazzoli, and Curt Weldon, as well as nine other individuals involved in fire safety issues,…

  14. A composite system approach to aircraft cabin fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Gilwee, W. J., Jr.; Lerner, N. R.; Hilado, C. J.; Labossiere, L. A.; Hsu, M.-T.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high-temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the bismaleimide composites is detailed.

  15. A composite system approach to aircraft cabin fire safety

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Parker, J. A.; Gilwee, W. J., Jr.; Lerner, N. R.; Hilado, C. J.; Labossiere, L. A.; Hsu, M. T. S.

    1976-01-01

    The thermochemical and flammability characteristics of two polymeric composites currently in use and seven others being considered for use as aircraft interior panels are described. The properties studied included: (1) limiting oxygen index of the composite constituents; (2) fire containment capability of the composite; (3) smoke evolution from the composite; (4) thermogravimetric analysis; (5) composition of the volatile products of thermal degradation; and (6) relative toxicity of the volatile products of pyrolysis. The performance of high temperature laminating resins such as bismaleimides is compared with the performance of phenolics and epoxies. The relationship of increased fire safety with the use of polymers with high anaerobic char yield is shown. Processing parameters of one of the baremaleimide composites are detailed.

  16. Integrated system of occupational safety and health and fire protection of the fire rescue brigades members.

    PubMed

    Božović, Marijola; Živković, Snežana; Mihajlović, Emina

    2018-06-01

    The objective of the conducted research is the identification and determination of requirements of members of fire rescue brigades during operations in the conditions of high risk in order to minimize the possibilities for injury incidence during the intervention. The research is focused on examination, determination and identification of factors affecting the increasing number of occupational injuries of members of fire rescue brigades during interventions. Hypothetical framework of the research problem consists of general hypothesis and six special hypotheses. Results suggest that almost all respondents believe that their skills and abilities are applicable in the intervention phase, but less than a half believe that their skills are applicable in prevention phase. Two-thirds of respondents stated that in their organization they have support for further education and upgrading while a half of respondents stated that they need education concerning identification, assessment and management of risks that can lead to emergency situations.

  17. 77 FR 4897 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-01

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, VA AGENCY: Coast... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule is effective in the CFR on February 1, 2012...

  18. 76 FR 31848 - Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ...-AA00 Safety Zone; M/V Del Monte Live-Fire Gun Exercise, James River, Isle of Wight, Virginia AGENCY... provide for the safety of life on navigable waters during the live-fire gun exercises on the M/V Del Monte... associated with the live-fire gun exercise. DATES: This rule will be effective from 11 a.m. June 6, 2011...

  19. Fight Fire Without Fire Fighters!

    ERIC Educational Resources Information Center

    Peacock, Richard D.

    1977-01-01

    There is a role for the classroom teacher in teaching fire safety. Discusses the inadequacies of present fire prevention programs and provides ten specific steps teachers can take to avoid suffering and death from fire. (Author/RK)

  20. NASA technical advances in aircraft occupant safety. [clear air turbulence detectors, fire resistant materials, and crashworthiness

    NASA Technical Reports Server (NTRS)

    Enders, J. H.

    1978-01-01

    NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.

  1. 30 CFR 75.1103-3 - Automatic fire sensor and warning device systems; minimum requirements; general.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensor and warning device systems; minimum requirements; general. 75.1103-3 Section 75.1103-3 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Fire Protection § 75.1103-3 Automatic fire sensor and warning device systems; minimum...

  2. Fire tests to evaluate the potential fire threat and its effects on HEPA filter integrity in cell ventilation at the Oak Ridge National Laboratory, Building 7920

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, H.K.; Staggs, K.J.; Doughty, S.M.

    1992-12-01

    As a result of a DOE (Tiger Team) Technical Safety Appraisal (November 1990) of the Radiochemical Engineering Development Center (REDC), ORNL Building 7920, a number of fire protection concerns were identified. The primary concern was the perceived loss of ventilation system containment due to the thermal destruction and/or breaching of the prefilters and/or high-efficiency particulate air filters (HEPA `s) and the resultant radioactive release to the external environment. The following report describes the results of an extensive fire test program performed by the Fire Research Discipline (FRD) of the Special Projects Division of Lawrence Livermore National Lab (LLNL) and fundedmore » by ORNL to address these concerns. Full scale mock-ups of a REDC hot cell tank pit, adjacent cubicle pit, and associated ventilation system were constructed at LLNL and 13 fire experiments were conducted to specifically answer the questions raised by the Tiger Team. Our primary test plan was to characterize the burning of a catastrophic solvent spill (kerosene) of 40 liters and its effect on the containment ventilation system prefilters and HEPA filters. In conjunction with ORNL and Lockwood Greene we developed a test matrix that assessed the fire performance of the prefilters and HEPA filters; evaluated the fire response of the fiber reinforced plastic (FRP) epoxy ventilation duct work; the response and effectiveness of the fire protection system, the effect of fire in a cubicle on the vessel off-gas (VOG) elbow, and other fire safety questions.« less

  3. Forest construction infrastructures for the prevision, suppression, and protection before and after forest fires

    NASA Astrophysics Data System (ADS)

    Drosos, Vasileios C.; Giannoulas, Vasileios J.; Daoutis, Christodoulos

    2014-08-01

    Climatic changes cause temperature rise and thus increase the risk of forest fires. In Greece the forests with the greatest risk to fire are usually those located near residential and tourist areas where there are major pressures on land use changes, while there are no currently guaranteed cadastral maps and defined title deeds because of the lack of National and Forest Cadastre. In these areas the deliberate causes of forest fires are at a percentage more than 50%. This study focuses on the forest opening up model concerning both the prevention and suppression of forest fires. The most urgent interventions that can be done after the fire destructions is also studied in relation to soil protection constructions, in order to minimize the erosion and the torrential conditions. Digital orthophotos were used in order to produce and analyze spatial data using Geographical Information Systems (GIS). Initially, Digital Elevation Models were generated, based on photogrammetry and forest areas as well as the forest road network were mapped. Road density, road distance, skidding distance and the opening up percentage were accurately measured for a forest complex. Finally, conclusions and suggestions have been drawn about the environmental compatibility of forest protection and wood harvesting works. In particular the contribution of modern technologies such as digital photogrammetry, remote sensing and Geographical Information Systems is very important, allowing reliable, effective and fast process of spatial analysis contributing to a successful planning of opening up works and fire protection.

  4. 33 CFR 149.641 - What are the structural fire protection requirements for accommodation spaces and modules?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the structural fire protection requirements for accommodation spaces and modules? 149.641 Section 149.641 Navigation and... national consensus standard, as that term is defined in 29 CFR 1910.2, for the structural fire protection...

  5. Fire Protection System for an Atrium Satisfies Code Intent

    ERIC Educational Resources Information Center

    Boehmer, Donald J.; Jensen, Rolf

    1975-01-01

    The Civic Center in Scarborough, Ontario, has an open interior design that incorporates an atrium. Fire protection elements include automatic sprinklers, provisions for efficient exiting of building occupants, and smoke evacuation by gravity exhaust. (Available from 1221 Avenue of the Americas, New York, NY 10020, $15.00 annually.) (Author/MLF)

  6. The application of machine vision in fire protection system

    NASA Astrophysics Data System (ADS)

    Rong, Jiang

    2018-04-01

    Based on the previous research, this paper introduces the theory of wavelet, collects the situation through the video system, and calculates the key information needed in the fire protection system. That is, through the algorithm to collect the information, according to the flame color characteristics and smoke characteristics were extracted, and as the characteristic information corresponding processing. Alarm system set the corresponding alarm threshold, when more than this alarm threshold, the system will alarm. This combination of flame color characteristics and smoke characteristics of the fire method not only improve the accuracy of judgment, but also improve the efficiency of judgments. Experiments show that the scheme is feasible.

  7. Fire safety of passenger trains : phase I : material evaluation (cone calorimeter)

    DOT National Transportation Integrated Search

    1999-01-01

    As part of the passenger equipment rulemaking required by Congress, the Federal Railroad Administration (FRA) has proposed that its existing fire safety guidelines be made mandatory. A major conclusion of a FRA-funded 1993 study by the National Insti...

  8. Directory of workers in the fire field

    NASA Technical Reports Server (NTRS)

    Kuvshinoff, B. W.; Mcleod, S. B.; Katz, R. G.

    1973-01-01

    A directory was compiled to provide a list of workers engaged in fire research, their addresses and affiliations, and their principal fields of activity. The initial criteria for the selection of names for the directory are recent contributions to fire literature, teaching of subjects relevant to fire science, or participation in or support of fire research programs. With some exceptions, fire service personnel and fire protection engineers were excluded because directories already exist for these professionals. Also excluded are investigators engaged principally in studies of propulsion, combustion, and explosion phenomena, because these areas of study are somewhat aside from the main focus of fire research. For purposes of the directory, fire science is taken to be the body of knowledge, art, and skill related to the investigation, analysis, and interpretation of the phenomena of unwanted fires and the evaluation of materials methods, systems, and equipment related to fire safety, prevention, detection, and suppression.

  9. 75 FR 44720 - Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-29

    ...-AA00 Safety Zone; Live-Fire Gun Exercise, M/V Del Monte, James River, VA AGENCY: Coast Guard, DHS... mariners from the hazards associated with live fire and explosive training events. DATES: This rule is... Hampton Roads was notified that the U.S. Navy will conduct a live fire and explosive training event...

  10. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  11. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  12. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  13. National Conference on Campus Safety (15th, University of Vermont, Burlington, June 21-26, 1968).

    ERIC Educational Resources Information Center

    Green, Jack N., Ed.

    Presentations made at the fifteenth National Conference on Campus Safety. The following topics are dealt with--(1) Occupational Health on Campus, (2) Teacher Liability in School Accidents, (3) Indoctrinating Students in Fire Safety, (4) Computer Installations Safety and Fire Protection, (5) The Design of Laboratory Buildings, (6) A Uniform System…

  14. Analyzing the Need for Special Operations Teams Within the Fire Service

    DTIC Science & Technology

    2011-06-01

    4. Military Special Operations Forces ....................................................7 5. Psychological Effects of Catastrophe...Security NYPD New York Police Department OSHA Occupational Safety & Health Administration PPE Personnel Protective Equipment PSA Psychological First...disregard for fire service life- safety standards within the community. Identifying and understanding the psychological implications, ethics, and

  15. Safety Rises to New Levels.

    ERIC Educational Resources Information Center

    Lafo, Joseph; Robillard, Marc

    2001-01-01

    Explains how high-rise residence halls can provide high-level safety and security at colleges and universities. Boston University is used to illustrate high-rise security and fire protection issues. (GR)

  16. Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.

    ERIC Educational Resources Information Center

    Texas State Commission on Fire Protection, Austin.

    This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…

  17. Fire!

    ERIC Educational Resources Information Center

    Jones, Rebecca

    1996-01-01

    The number of school fires is up nationwide. This article describes unsafe school conditions, problems with new fire codes, and the factors that contribute to school fires. Installation of sprinkler systems is recommended. A fire-safety checklist is included. (LMI)

  18. Fire Prevention and Safety: A Teacher's Handbook, 1986-87.

    ERIC Educational Resources Information Center

    Kominski, John; And Others

    This collection of teaching materials will help teachers make pupils aware of the need to avoid and prevent situations which might result in fires and to master some simple life-saving techniques to protect themselves and others. The handbook contains information sheets, charts, pictures, diagrams, and suggestions for lessons and activities. Topic…

  19. Oriented clay nanopaper from biobased components--mechanisms for superior fire protection properties.

    PubMed

    Carosio, F; Kochumalayil, J; Cuttica, F; Camino, G; Berglund, L

    2015-03-18

    The toxicity of the most efficient fire retardant additives is a major problem for polymeric materials. Cellulose nanofiber (CNF)/clay nanocomposites, with unique brick-and-mortar structure and prepared by simple filtration, are characterized from the morphological point of view by scanning electron microscopy and X-ray diffraction. These nanocomposites have superior fire protection properties to other clay nanocomposites and fiber composites. The corresponding mechanisms are evaluated in terms of flammability (reaction to a flame) and cone calorimetry (exposure to heat flux). These two tests provide a wide spectrum characterization of fire protection properties in CNF/montmorrilonite (MTM) materials. The morphology of the collected residues after flammability testing is investigated. In addition, thermal and thermo-oxidative stability are evaluated by thermogravimetric analyses performed in inert (nitrogen) and oxidative (air) atmospheres. Physical and chemical mechanisms are identified and related to the unique nanostructure and its low thermal conductivity, high gas barrier properties and CNF/MTM interactions for char formation.

  20. Utilization of available skills and materials in fire prevention

    NASA Technical Reports Server (NTRS)

    Martin, H. W.

    1971-01-01

    Procedures for installing fire protection systems in large buildings are discussed. Factors considered in the safety management are: (1) distribution of water supply, (2) design and location of exits, (3) emergency power system, and (4) maintenance procedures.