Sample records for safety system injection

  1. Passive safety injection system using borated water

    DOEpatents

    Conway, Lawrence E.; Schulz, Terry L.

    1993-01-01

    A passive safety injection system relies on differences in water density to induce natural circulatory flow patterns which help maintain prescribed concentrations of boric acid in borated water, and prevents boron from accumulating in the reactor vessel and possibly preventing heat transfer.

  2. [Systemic safety following intravitreal injections of anti-VEGF].

    PubMed

    Baillif, S; Levy, B; Girmens, J-F; Dumas, S; Tadayoni, R

    2018-03-01

    The goal of this manuscript is to assess data suggesting that intravitreal injection of anti-vascular endothelial growth factors (anti-VEGFs) could result in systemic adverse events (AEs). The class-specific systemic AEs should be similar to those encountered in cancer trials. The most frequent AE observed in oncology, hypertension and proteinuria, should thus be the most common expected in ophthalmology, but their severity should be lower because of the much lower doses of anti-VEGFs administered intravitreally. Such AEs have not been frequently reported in ophthalmology trials. In addition, pharmacokinetic and pharmacodynamic data describing systemic diffusion of anti-VEGFs should be interpreted with caution because of significant inconsistencies reported. Thus, safety data reported in ophthalmology trials and pharmacokinetic/pharmacodynamic data provide robust evidence that systemic events after intravitreal injection are very unlikely. Additional studies are needed to explore this issue further, as much remains to be understood about local and systemic side effects of anti-VEGFs. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  3. System Study: High-Pressure Safety Injection 1998-2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schroeder, John Alton

    2015-12-01

    This report presents an unreliability evaluation of the high-pressure safety injection system (HPSI) at 69 U.S. commercial nuclear power plants. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPSI results.

  4. Fault Injection Validation of a Safety-Critical TMR Sysem

    NASA Astrophysics Data System (ADS)

    Irrera, Ivano; Madeira, Henrique; Zentai, Andras; Hergovics, Beata

    2016-08-01

    Digital systems and their software are the core technology for controlling and monitoring industrial systems in practically all activity domains. Functional safety standards such as the European standard EN 50128 for railway applications define the procedures and technical requirements for the development of software for railway control and protection systems. The validation of such systems is a highly demanding task. In this paper we discuss the use of fault injection techniques, which have been used extensively in several domains, particularly in the space domain, to complement the traditional procedures to validate a SIL (Safety Integrity Level) 4 system for railway signalling, implementing a TMR (Triple Modular Redundancy) architecture. The fault injection tool is based on JTAG technology. The results of our injection campaign showed a high degree of tolerance to most of the injected faults, but several cases of unexpected behaviour have also been observed, helping understanding worst-case scenarios.

  5. [Necessity of applying pharmacovigilance in post-marketing safety monitoring of traditional Chinese medicine injections].

    PubMed

    Wang, Hai-Nan; Chen, Wen; Fu, Zheng; Du, Wen-min; He, Jia

    2008-03-01

    Traditional Chinese medicine (TCM) injection has become one of the hotspots in the new TCM research and development. The serious adverse drug reactions happened in clinical have arosed attention widely in the whole society. It's very urgent to monitor the post-marketing safety of TCM injections. This paper elucidated the pharmacovigilance's necessity in the post-marketing safety monitoring of TCM injections, basing on the reason of safety problem of TCM injections and the future developing trend of adverse drug reaction monitoring. Also, this paper introduced the rapid signal detection method of spontaneous reporting system database by data mining technology.

  6. Evaluation of the acute and chronic safety of the biosense injection catheter system in porcine hearts.

    PubMed

    Kornowski, R; Fuchs, S; Tio, F O; Pierre, A; Epstein, S E; Leon, M B

    1999-12-01

    Direct myocardial injection of therapeutic agents has been explored as a new method for myocardial revascularization. The integration of a 3D electromechanical mapping catheter with a retractable injection needle should allow for intramyocardial injection to identified sites, obviating the need for open heart surgery. This study assessed the procedural safety and performance characteristics of a novel guided catheter-based transendocardial injection system. The electromagnetic guidance system was coupled with a retrievable 27G needle for left ventricular endocardial injection. Using this system, we injected, transendocardially, methylene-blue (MB) dye tracer at a volume of 0.1 or 0.2 ml per injection in eight normal pigs. Animals were sacrificed acutely, at 1, 3, and 7 days (two animal in each time). Three animals served as controls. The injections were followed by coronary angiography and echocardiogram to assess possible ventricular or coronary perforation and wall motion abnormalities. CK-MB levels were measured up to 24 hr following the procedure. The animals were sacrificed at the assigned time for gross and histopathology evaluation. A total of 101 injections were made in all regions of the heart except the apex and the mitral valve. No animal died as a result of the mapping or injection procedures. Vital signs did not change relative to baseline after the mapping and injection procedures. CK-MB values did not increase over time and there was no evidence of sustained arrhythmia or hemodynamic compromise. There was no evidence of left ventricular or coronary perforation, global or regional wall motion abnormalities, or hemopericardium. On histologic evaluation, the estimated volume of tissue staining was greater than the volume of the injected MB dye due to dispersion of the injectate in the interstitial and intracellular fluid compartments. It is concluded that using this magnetic guidance catheter-based navigational system, it is feasible and safe to perform

  7. [Study of post marketing safety reevaluation of shenqi fuzheng injection].

    PubMed

    Ai, Qing-Hua; Li, Yuan-Yuan; Xie, Yan-Ming

    2014-09-01

    In order to promote the Shenqifuzheng injection (SQFZ) clinical medication safety, this study reevaluate on SQFZ post marketing safety study systematically. Including multi center large sample registration type safety monitoring research, the analysis based on national spontaneous reporting system data, the analysis based on the 20 national hospital information system data and literature research. Above the analysis, it suggests that SQFZ has good security. The more adverse drug reaction (ADR) as allergic reactions, mainly involved in the damage of skin, appendages and its systemic damage, serious person can appear allergic shock. ADR/E is more common in the elderly, may be related to medication (tumor) populations. Early warning analysis based on SRS data and literature research are of the view that "phlebitis" has a strong association with SQFZ used.

  8. Injection safety practices in a main referral hospital in Northeastern Nigeria.

    PubMed

    Gadzama, G B; Bawa, S B; Ajinoma, Z; Saidu, M M; Umar, A S

    2014-01-01

    No adherence of safe injection policies remains a major challenge, and, worldwide, annually, it leads to 21 million new hepatitis B cases and 260,000 HIV infection cases. This descriptive observational survey was conducted to determine the level of adherence to universal precaution for safe injection practices in the hospital. The study units were selected using a simple random sampling of injection services provider/phlebotomist in 27 units/wards of the hospital. The study instruments were observation checklist and interviewer administered questionnaires. EPI info (version 3.5.2) software was used for data entry and generation of descriptive statistics was done with units of analysis (units/wards) on injection safety practices of health workers, availability of logistics and supplies, and disposal methods. Only 33.3% of the units (95% CI, 16-54) had non-sharps infectious healthcare waste of any type inside containers specific for non-sharps infectious waste and 17 (77.3%) of the observed therapeutic injections were prepared on a clean, dedicated table or tray, where contamination of the equipment with blood, body fluids, or dirty swabs was unlikely. Absence of recapping of needles was observed in 11 (50.0%) units giving therapeutic injections. Only 7.4% of units surveyed had separate waste containers for infectious non-sharps. This study depicts poor knowledge and a practice of injection safety, inadequate injection safety supplies, and non-compliance to injection safety policy and guidelines.

  9. Assessment of the safety of injection practices and injection-related procedures in family health units and centers in Alexandria.

    PubMed

    Elhoseeny, Taghareed A; Mourad, Juidan K

    2014-08-01

    The Safe Injection Global Network (SIGN) developed an intervention strategy for reducing overuse of injections and promoting the administration of safe injections. Tool C--Revised is designed to assess the safety of the most common procedures that puncture the skin within health services. The aim of the study was to assess injection safety within the primary healthcare facilities in Alexandria using Tool C--Revised. A total of 45 family health units and centers in Alexandria were selected by proportional allocation from the eight regions of Alexandria. The Tool C--Revised of the WHO was used for observation of the entire facility, injection practices and injection-related procedures, and sterilization practices. Interview of different health providers and immediate supervisor of injections was carried out. Indicators that reflect risk included: deficiency of alcohol-based hand rub for cleansing hands (13.3%), compliance with hand wash before preparing a procedure (56.9% before injection practices, 61.3% before phlebotomy, and 67.6% before lancet puncture), and wearing a new pair of gloves before new procedures (48.6% before injection practices, 9.7% for phlebotomy, 11.8% for lancet puncture, and 80% for both intravenous injections and infusions). Enough disposable equipment in all facilities for at least 2 weeks dependent on the statement of the average numbers of procedures per week was shown. Only 38% of the providers had received training regarding injection safety in the last 2 years and 62.5% had completed their three doses of hepatitis B vaccine. Only 42.2% of staffs who handled healthcare waste had access to heavy gloves. Indicators related to injection and injection-related practices that reflect risk to patients include deficiency of alcohol-based hand rub tools, nonadherence to hand hygiene before preparing an injection, and inadequate adherence to using a clean barrier when opening a glass ampule and use of gloves. Indicators that may reflect risk to

  10. Safety of immunization injections in Africa: not simply a problem of logistics.

    PubMed Central

    Dicko, M.; Oni, A. Q.; Ganivet, S.; Kone, S.; Pierre, L.; Jacquet, B.

    2000-01-01

    In 1995, the WHO Regional Office for Africa launched a logistics project to address the four main areas of immunization logistics: the cold chain, transport, vaccine supply and quality, and the safety of injections in the countries of the region. The impact of this logistic approach on immunization injection safety was evaluated through surveys of injection procedures and an analysis of the injection materials (e.g. sterilizable or disposable syringes) chosen by the Expanded Programme on Immunization (EPI) and those actually seen to be used. Re-use of injection materials without sterilization, accidental needle-stick injuries among health care workers, and injection-related abscesses in patients were common in countries in the WHO African Region. Few health centres used time-steam saturation-temperature (TST) indicators to check the quality of sterilization and, in many centres, the injection equipment was boiled instead of being steam sterilized. Facilities for the proper disposal of used materials were rarely present. Although the official EPI choice was to use sterilizable equipment, use of a combination of sterilizable and disposable equipment was observed in the field. Unsafe injection practices in these countries were generally due to a failure to integrate nursing practices and public awareness with injection safety issues, and an absence of the influence of EPI managers on health care service delivery. Holistic rather than logistic approaches should be adopted to achieve safe injections in immunization, in the broader context of promoting safe vaccines and safety of all injections. PMID:10743280

  11. Assessment of injection safety in Ha Dong General Hospital, Hanoi, in 2012.

    PubMed

    Van Tuong, Phan; Phuong, Tran Thi Minh; Anh, Bui Thi My; Nguyen, Trang Huyen Thi

    2017-01-01

    Background : Injection is one of the most frequently used medical methods to introduce drugs or other substances into the body for purposes of treatment or prevention. Unsafe injection can cause adverse outcomes, such as abscess and anaphylactic shock, and increases the risk of blood-borne transmission of viruses to patients and health care workers, as well as the community. Recognizing the importance of injection safety, in 2000 the Vietnamese Ministry of Health (MOH) collaborated with the Vietnam Nurses Association to launch the "Safe injection" program throughout the country, including Hanoi. Methods : This cross-sectional study, combining quantitative and qualitative analysis, was conducted from February to August 2012 in Ha Dong General Hospital using a structured questionnaire and observation checklist. The target population of the study was 109 nurses working in clinical departments and 436 injections were observed. Results : The percentage of nurses who are familiar with injection safety standards was found to be 82.6%. The proportion of practical injections that met the 23 standards of injection safety set by the MOH amounted to 22.2%. The factors related to safe injection practice of nurses who were younger age group (OR=3.1; p<0.05) and fewer number of years working as a nurse (OR=2.8; p<0.05). Conclusions : While nurses have high level of knowledge about safe injections but a small proportion actually practiced. Experience may not always guarantee safe practices.  Injection safety training should be regularly imparted upon all categories of nurses.

  12. [Establishment of model of traditional Chinese medicine injections post-marketing safety monitoring].

    PubMed

    Guo, Xin-E; Zhao, Yu-Bin; Xie, Yan-Ming; Zhao, Li-Cai; Li, Yan-Feng; Hao, Zhe

    2013-09-01

    To establish a nurse based post-marketing safety surveillance model for traditional Chinese medicine injections (TCMIs). A TCMIs safety monitoring team and a research hospital team engaged in the research, monitoring processes, and quality control processes were established, in order to achieve comprehensive, timely, accurate and real-time access to research data, to eliminate errors in data collection. A triage system involving a study nurse, as the first point of contact, clinicians and clinical pharmacists was set up in a TCM hospital. Following the specified workflow involving labeling of TCM injections and using improved monitoring forms it was found that there were no missing reports at the ratio of error was zero. A research nurse as the first and main point of contact in post-marketing safety monitoring of TCM as part of a triage model, ensures that research data collected has the characteristics of authenticity, accuracy, timeliness, integrity, and eliminate errors during the process of data collection. Hospital based monitoring is a robust and operable process.

  13. Experimental study on the instability of Pressure Balance Injection System (PBIS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Okamoto, Koji; Teshima, Hideyuki; Madarame, Haruki

    1996-06-01

    The Passive Safety Reactor has been developed to reduce the construction cost and to improve the safety. Japan Atomic Energy Research institute (JAERI) proposed the System-Integrated Pressurized Water Reactor (SPWR) as a Passive Safety Reactor. In the SPWR design, the Pressure Balanced Injection System (PBIS) was introduced for the passive safety concept. The water with boron in a containment vessel were passively injected into the core by the pressure difference between the containment vessel and reactor vessel at a severe accidental condition. However there are few studies on the thermo-hydraulic characteristics of the PBIS. In this study, the thermal hydraulicsmore » of the PBIS are experimentally investigated using the small scale model. The instability of the injected flow was observed in the adiabatic experiment. The instability was caused by the pressure balance between the two vessels. The mechanism of the instability are discussed, resulting in the good agreement with the experimental results. In the steam experiment, another instability was observed, which was caused by the heat balance in the main tank.« less

  14. Assessment of injection safety in Ha Dong General Hospital, Hanoi, in 2012

    PubMed Central

    Van Tuong, Phan; Phuong, Tran Thi Minh; Anh, Bui Thi My; Nguyen, Trang Huyen Thi

    2017-01-01

    Background: Injection is one of the most frequently used medical methods to introduce drugs or other substances into the body for purposes of treatment or prevention. Unsafe injection can cause adverse outcomes, such as abscess and anaphylactic shock, and increases the risk of blood-borne transmission of viruses to patients and health care workers, as well as the community. Recognizing the importance of injection safety, in 2000 the Vietnamese Ministry of Health (MOH) collaborated with the Vietnam Nurses Association to launch the “Safe injection” program throughout the country, including Hanoi. Methods: This cross-sectional study, combining quantitative and qualitative analysis, was conducted from February to August 2012 in Ha Dong General Hospital using a structured questionnaire and observation checklist. The target population of the study was 109 nurses working in clinical departments and 436 injections were observed. Results: The percentage of nurses who are familiar with injection safety standards was found to be 82.6%. The proportion of practical injections that met the 23 standards of injection safety set by the MOH amounted to 22.2%. The factors related to safe injection practice of nurses who were younger age group (OR=3.1; p<0.05) and fewer number of years working as a nurse (OR=2.8; p<0.05). Conclusions: While nurses have high level of knowledge about safe injections but a small proportion actually practiced. Experience may not always guarantee safe practices.  Injection safety training should be regularly imparted upon all categories of nurses. PMID:29188014

  15. Study of status of safe injection practice and knowledge regarding injection safety among primary health care workers in Baglung district, western Nepal.

    PubMed

    Gyawali, Sudesh; Rathore, Devendra S; Kc, Bhuvan; Shankar, P Ravi

    2013-01-03

    Unsafe injection practices and injection overuse are widespread in developing countries harming the patient and inviting risks to the health care workers. In Nepal, there is a dearth of documented information about injection practices so the present study was carried out: a) to determine whether the selected government health facilities satisfy the conditions for safe injections in terms of staff training, availability of sterile injectable equipment and their proper disposal after use and b) to assess knowledge and attitudes of healthcare workers in these health care facilities with regard to injection safety. A descriptive cross-sectional mixed type (qualitative and quantitative) survey was carried out from 18th May to 16th June 2012. In-depth interviews with the in-charges were conducted using a semi-structured questionnaire. Observation of the health facilities using a structured observation tool was done. The data were analysed manually by summarizing, tabulating and presenting in various formats. The in-charges (eight males, two females) who participated in the study ranged in age from 30 to 50 years with a mean age of 37.8 years. Severe infection followed by pain was the most important cause for injection use with injection Gentamicin being most commonly prescribed. New single use (disposable) injections and auto-disable syringes were used to inject curative drugs and vaccines respectively. Sufficient safety boxes were also supplied to dispose the used syringe. All health care workers had received full course of Hepatitis B vaccine and were knowledgeable about at least one pathogen transmitted through unsafe injection practices. Injection safety management policy and waste disposal guideline was not available for viewing in any of the facilities. The office staff who disposed the bio-medical wastes did so without taking any safety measures. Moreover, none of these staff had received any formal training in waste management. Certain safe injection

  16. Study of status of safe injection practice and knowledge regarding injection safety among primary health care workers in Baglung district, western Nepal

    PubMed Central

    2013-01-01

    Background Unsafe injection practices and injection overuse are widespread in developing countries harming the patient and inviting risks to the health care workers. In Nepal, there is a dearth of documented information about injection practices so the present study was carried out: a) to determine whether the selected government health facilities satisfy the conditions for safe injections in terms of staff training, availability of sterile injectable equipment and their proper disposal after use and b) to assess knowledge and attitudes of healthcare workers in these health care facilities with regard to injection safety. Methodology A descriptive cross-sectional mixed type (qualitative and quantitative) survey was carried out from 18th May to 16th June 2012. In-depth interviews with the in-charges were conducted using a semi-structured questionnaire. Observation of the health facilities using a structured observation tool was done. The data were analysed manually by summarizing, tabulating and presenting in various formats. Results The in-charges (eight males, two females) who participated in the study ranged in age from 30 to 50 years with a mean age of 37.8 years. Severe infection followed by pain was the most important cause for injection use with injection Gentamicin being most commonly prescribed. New single use (disposable) injections and auto-disable syringes were used to inject curative drugs and vaccines respectively. Sufficient safety boxes were also supplied to dispose the used syringe. All health care workers had received full course of Hepatitis B vaccine and were knowledgeable about at least one pathogen transmitted through unsafe injection practices. Injection safety management policy and waste disposal guideline was not available for viewing in any of the facilities. The office staff who disposed the bio-medical wastes did so without taking any safety measures. Moreover, none of these staff had received any formal training in waste management

  17. Injection safety among primary health care workers in Jazan Region, Saudi Arabia.

    PubMed

    Ismail, A A; Mahfouz, M S; Makeen, A

    2014-07-01

    Occupational exposure to percutaneous injuries is a substantial source of infections with blood-borne pathogens among health-care workers. Few studies evaluated injection safety practices in Saudi Arabia. To examine the structure and process of injection safety at primary health care level in Jazan health district, to evaluate knowledge, attitudes, and practices of primary health care physicians and nurses towards injection safety, and to determine the incidence of needle stick injuries among health care workers in Jazan region, Saudi Arabia. A cross-sectional study was conducted in Jazan primary health care centers (PHCCs), Saudi Arabia from September 2011 to March 2012. Data were collected using an observational checklist and data collection sheet. Jazan city health district was chosen at random from the 14 health sectors in Jazan region. All the 33 (10 urban, and 23 rural) PHCCs of Jazan city were included in this study to get the predetermined sample size of health care workers. 200 health care workers (HCWs) were recruited (29% physicians, and 71% nurses). Syringes in the PHCCs were disposable (100%), individually packed (92%), and available at all volumes (98%). Methods of safe disposal of needles and sharps were also operated through contracting with professional companies in 84.8% of instances. Urban PHCCs had more posts for injection safety promotion than rural centers (p=0.02). Continuous Medical Education (CME) programs on infection control were present in only 60% of PHCCs. At least 95% of HCWs in Jazan believed that sharp objects should be kept in a puncture-proof container, kept in a closed container, or disposed by a professional company. More than 80% of HCWs washed their hands by soap and water and cleaned them by alcohol before giving injection, and also got the three doses of hepatitis B vaccine.The rate of needle stick injury in the past year was 14%, without a significant difference between nurses and physicians (p=0.8). Jazan PHCCs have

  18. [Comparative study on four kinds of assessment methods of post-marketing safety of Danhong injection].

    PubMed

    Li, Xuelin; Tang, Jinfa; Meng, Fei; Li, Chunxiao; Xie, Yanming

    2011-10-01

    To study the adverse reaction of Danhong injection with four kinds of methods, central monitoring method, chart review method, literature study method and spontaneous reporting method, and to compare the differences between them, explore an appropriate method to carry out post-marketing safety evaluation of traditional Chinese medicine injection. Set down the adverse reactions' questionnaire of four kinds of methods, central monitoring method, chart review method, literature study method and collect the information on adverse reactions in a certain period. Danhong injection adverse reaction information from Henan Province spontaneous reporting system was collected with spontaneous reporting method. Carry on data summary and descriptive analysis. Study the adverse reaction of Danhong injection with four methods of central monitoring method, chart review method, literature study method and spontaneous reporting method, the rates of adverse events were 0.993%, 0.336%, 0.515%, 0.067%, respectively. Cyanosis, arrhythmia, hypotension, sweating, erythema, hemorrhage dermatitis, rash, irritability, bleeding gums, toothache, tinnitus, asthma, elevated aminotransferases, constipation, pain are new discovered adverse reactions. The central monitoring method is the appropriate method to carry out post-marketing safety evaluation of traditional Chinese medicine injection, which could objectively reflect the real world of clinical usage.

  19. Long-acting atypical injectable antipsychotics in the treatment of schizophrenia: safety and tolerability review.

    PubMed

    Cañas, Fernando; Möller, Hans-Jürgen

    2010-09-01

    Although atypical antipsychotics have beneficial efficacy and tolerance, non-adherence and partial adherence remain in patients treated for schizophrenia. Long-acting injectable or depot atypical antipsychotics offer better medication adherence and tolerability advantages. Currently, two drugs are available for the treatment of schizophrenia, risperidone long-acting injectable (RLAI) and olanzapine pamoate (OP). Short- and long-term safety and tolerability data on RLAI and OP from January 2006 through September 2009 were reviewed by performing Medline and PubMed searches, reviewing abstracts and poster presentations, and viewing available material from the FDA and European Medicines Agency. RLAI and OP show good short- and long-term safety when treating patients with schizophrenia, with uncommon discontinuation due to adverse effects. RLAI and OP data show rare problems with injection site reactions and patients exposed to injectable treatments prefer to continue injections. Infrequent but serious post-injection delirium sedation syndrome occurred after 1% of OP injections. Weight gain was generally higher among patients treated with OP versus RLAI. Healthcare providers, patients and family members should be made aware of the safety and benefits of long-acting injectable atypical antipsychotics in order to diminish the unnecessary restrictions of these therapies for patients with schizophrenia.

  20. Novel electric power-driven hydrodynamic injection system for gene delivery: safety and efficacy of human factor IX delivery in rats.

    PubMed

    Yokoo, T; Kamimura, K; Suda, T; Kanefuji, T; Oda, M; Zhang, G; Liu, D; Aoyagi, Y

    2013-08-01

    The development of a safe and reproducible gene delivery system is an essential step toward the clinical application of the hydrodynamic gene delivery (HGD) method. For this purpose, we have developed a novel electric power-driven injection system called the HydroJector-EM, which can replicate various time-pressure curves preloaded into the computer program before injection. The assessment of the reproducibility and safety of gene delivery system in vitro and in vivo demonstrated the precise replication of intravascular time-pressure curves and the reproducibility of gene delivery efficiency. The highest level of luciferase expression (272 pg luciferase per mg of proteins) was achieved safely using the time-pressure curve, which reaches 30 mm Hg in 10 s among various curves tested. Using this curve, the sustained expression of a therapeutic level of human factor IX protein (>500 ng ml(-1)) was maintained for 2 months after the HGD of the pBS-HCRHP-FIXIA plasmid. Other than a transient increase in liver enzymes that recovered in a few days, no adverse events were seen in rats. These results confirm the effectiveness of the HydroJector-EM for reproducible gene delivery and demonstrate that long-term therapeutic gene expression can be achieved by automatic computer-controlled hydrodynamic injection that can be performed by anyone.

  1. Injection System for Multi-Well Injection Using a Single Pump

    PubMed Central

    Wovkulich, Karen; Stute, Martin; Protus, Thomas J.; Mailloux, Brian J.; Chillrud, Steven N.

    2015-01-01

    Many hydrological and geochemical studies rely on data resulting from injection of tracers and chemicals into groundwater wells. The even distribution of liquids to multiple injection points can be challenging or expensive, especially when using multiple pumps. An injection system was designed using one chemical metering pump to evenly distribute the desired influent simultaneously to 15 individual injection points through an injection manifold. The system was constructed with only one metal part contacting the fluid due to the low pH of the injection solutions. The injection manifold system was used during a three-month pilot scale injection experiment at the Vineland Chemical Company Superfund site. During the two injection phases of the experiment (Phase I = 0.27 L/min total flow, Phase II = 0.56 L/min total flow), flow measurements were made 20 times over three months; an even distribution of flow to each injection well was maintained (RSD <4%). This durable system is expandable to at least 16 injection points and should be adaptable to other injection experiments that require distribution of air-stable liquids to multiple injection points with a single pump. PMID:26140014

  2. Nursing benefits of using an automated injection system for ictal brain single photon emission computed tomography.

    PubMed

    Vonhofen, Geraldine; Evangelista, Tonya; Lordeon, Patricia

    2012-04-01

    The traditional method of administering radioactive isotopes to pediatric patients undergoing ictal brain single photon emission computed tomography testing has been by manual injections. This method presents certain challenges for nursing, including time requirements and safety risks. This quality improvement project discusses the implementation of an automated injection system for isotope administration and its impact on staffing, safety, and nursing satisfaction. It was conducted in an epilepsy monitoring unit at a large urban pediatric facility. Results of this project showed a decrease in the number of nurses exposed to radiation and improved nursing satisfaction with the use of the automated injection system. In addition, there was a decrease in the number of nursing hours required during ictal brain single photon emission computed tomography testing.

  3. WISE recommendations to ensure the safety of injections in diabetes.

    PubMed

    Strauss, K

    2012-01-01

    Injections and fingersticks administered to patients with diabetes in health care settings present a risk of blood exposure to the injector as well as other workers in potential contact with sharps. Such exposures could lead to transmission of bloodborne pathogens such as hepatitis and HIV. A recent EU Directive requires that where such risks have been identified, processes and devices must be put in place to reduce or eliminate the risk. The aim of this paper is to provide formal guidelines on the application of this Directive to diabetes care settings. These evidence-based recommendations were written and vetted by a large group of international safety experts. A systematic literature search was conducted for all peer-reviewed studies and publications which bear on sharps safety in diabetes. Initially a group of experts reviewed this literature and drafted the recommendations. These were then presented for review, debate and revision to 57 experts from 14 countries at the WISE workshop in October, 2011. After the WISE meeting, the revised Recommendations were circulated electronically to attendees on three occasions, each time in a new iteration with revisions. Each recommendation was graded by the weight it should have in daily practice and by its degree of support in the medical literature. The topics covered include Risks of Sharps Injury and Muco-cutaneous Exposure, The EU Directive, Device Implications, Injection Technique Implications, Education and Training (Creating a "Safety Culture"), Value, Awareness and Responsibility. These safety recommendations provide practical guidance and fill an important gap in diabetes management. If followed, they should help ensure safe, effective and largely injury-free injections and fingersticks. They will serve as the roadmap for applying the new EU Directive to diabetes care. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  4. Evaluation of performance, safety, subject acceptance, and compliance of a disposable autoinjector for subcutaneous injections in healthy volunteers.

    PubMed

    Berteau, Cecile; Schwarzenbach, Florence; Donazzolo, Yves; Latreille, Mathilde; Berube, Julie; Abry, Herve; Cotten, Joël; Feger, Celine; Laurent, Philippe E

    2010-10-05

    A disposable autoinjector was developed for subcutaneous (SC) self-injection by patients with chronic diseases. To verify its performance and evaluate its acceptance, a clinical study was conducted in healthy volunteers, comparing SC injections performed by subjects using the autoinjector with SC injections performed by nurses using a syringe. This was a randomized, single-center, crossover study comparing SC self-injection using an autoinjector with SC nurse-administered injection using a syringe. Two volumes (0.2 mL and 1 mL) were injected into healthy volunteers. Study objectives included assessment of the accuracy and consistency of the volume injected by the injection systems, and skin reaction and pain associated with the injection. The fluid depot in the SC tissue layer was evaluated by ultrasound. Subject acceptance was evaluated using questionnaires on attitudes and emotions towards the injection technique, and challenged by seeking the subjects' preferred system for a final study injection or future treatment. A total of 960 injections (480 with autoinjector, 480 with syringe) were performed in 40 subjects. There were no significant differences in mean fluid leakage and injected volumes between the systems. Pain associated with the injection was significantly lower with the auto-injector than with the syringe. Local skin reaction at the injection site was overall satisfactory. Injections were appropriately performed by all subjects. At study end, all 40 subjects preferred the autoinjector for a final study injection and for future treatment. This study indicated that the autoinjector used by the subject was similar to a syringe used by a nurse in terms of performance and safety in administering the injections, and better in terms of pain, overall acceptance, and preference.

  5. Assistive Device for Efficient Intravitreal Injections.

    PubMed

    Ullrich, Franziska; Michels, Stephan; Lehmann, Daniel; Pieters, Roel S; Becker, Matthias; Nelson, Bradley J

    2016-08-01

    Intravitreal therapy is the most common treatment for many chronic ophthalmic diseases, such as age-related macular degeneration. Due to the increasing worldwide demand for intravitreal injections, there exists a need to render this medical procedure more time- and cost-efficient while increasing patient safety. The authors propose a medical assistive device that injects medication intravitreally. Compared to the manual intravitreal injection procedure, an automated device has the potential to increase safety for patients, decrease procedure times, allow for integrated data storage and documentation, and reduce costs for medical staff and expensive operating rooms. This work demonstrates the development of an assistive injection system that is coarsely positioned over the patient's head by the human operator, followed by automatic fine positioning and intravitreal injection through the pars plana. Several safety features, such as continuous eye tracking and iris recognition, have been implemented. The functioning system is demonstrated through ex vivo experiments with porcine eyes. [Ophthalmic Surg Lasers Imaging Retina. 2016;47:752-762.]. Copyright 2016, SLACK Incorporated.

  6. Epidural steroid injections: update on efficacy, safety, and newer medications for injection.

    PubMed

    Kozlov, N; Benzon, H T; Malik, K

    2015-08-01

    The best evidence for epidural injection appears to be in the setting of radicular pain with epidural steroid and non-steroid injections more efficacious than non-epidural injections. Studies showed the efficacy of non-particulate steroid to approach the efficacy of particulate steroid and very limited comparisons demonstrated no significant difference between epidural steroid and epidural non-steroid (local anesthetic) injection. Preliminary studies evaluating epidural injection of disease modifying anti-rheumatic drugs such etanercept and tocilizumab showed conflicting results and had significant limitations. Randomized studies support better efficacy of transforaminal injection due to greater incidence of ventral epidural spread of injectate when compared to interlaminar injection. Thus, the transforaminal approach is recommended when unilateral radicular pain is limited to one nerve root. However, the transforaminal approach is associated with greater incidence of central nervous system injury, including paraplegia, attributed to embolization of the particulate steroid. Recent studies showed that non-particulate steroids potentially last as long as particulate steroids. Therefore non-particulate steroid should be used in initial transforaminal epidural injection. Future studies should look into the role of adjunct diagnostic aids, including digital subtraction angiography, in detecting intravascular injection and the ideal site of needle placement, whether it is the safe triangle or the triangle of Kambin. Finally, the role of epidural disease -modifying antirheumatic drugs in the management of back pain needs to be better elucidated.

  7. Efficiency and safety of subconjunctival injection of anti-VEGF agent - bevacizumab - in treating dry eye.

    PubMed

    Jiang, Xiaodan; Lv, Huibin; Qiu, Weiqiang; Liu, Ziyuan; Li, Xuemin; Wang, Wei

    2015-01-01

    Dry eye is a chronic inflammatory ocular surface disease with high prevalence. The current therapies for dry eye remain to be unspecific and notcomprehensive. This study aims to explore safety and efficacy of a novel treatment - subconjunctival injection of bevacizumab - in dry eye patients. Sixty-four eyes of 32 dry eye patients received subconjunctival injection of 100 μL 25 mg/mL bevacizumab. Dry eye symptoms, signs (corrected visual acuity, intraocular pressure, conjunctival vascularity, corneal staining, tear break-up time, Marx line score, and blood pressure), and conjunctival impression cytology were evaluated 3 days before and 1 week, 1 month, and 3 months after injection. Significant improvements were observed in dry eye symptoms, tear break-up time, and conjunctival vascularization area at all the visits after injection compared to the baseline (P<0.05). The density of the goblet cell increased significantly at 1 month and 3 months after injection (P<0.05). There was no visual and systemic threat observed in any patient. Subconjunctival injection of 100 μL 25 mg/mL bevacizumab is a safe and efficient treatment for ocular surface inflammation of dry eye disease.

  8. [Needle-free injection--science fiction or comeback of an almost forgotten drug delivery system?].

    PubMed

    Ziegler, Andreas

    2007-08-01

    The first to create a "needle-free injector" was the American anesthetist Robert A. Hingson, 65 year ago. Since that time those devices underwent a changeful history. In 1986 an outbreak of hepatitis B among patients receiving injections from a needle-free multiple-use-nozzle injector was documented and related to the use of the injector device. Due to such risk of transmission of infection with these reusable devices, their application has been restricted. In 1998 the WHO recommended that only conventional needles and syringes should be used for immunization until safe needle-free injectors are identified through independent safety testing. Since needle-free injection has shown numerous advantages in comparison to conventional injection, new systems were developed that combine the advantages of needle-free injection with sufficient safety in mass vaccination programs. As an alternative to this early injector type, the disposable-cartridge injectors were developed. The newest research field in the area of the needle-free injection systems opened with the development of powder injectors, in which the drug preparation is no longer a suspension or solution, but a powdered solid. This injector type using powder formulations shows a number of advantages in comparison with the conventional needle/syringe injection technique as well as towards the liquid jet injectors. Due to this new kind of injectors the comeback of the needle-free injection technique in large-scale vaccination programs of the WHO seems reasonable and within reach.

  9. Reductant injection and mixing system

    DOEpatents

    Reeves, Matt; Henry, Cary A.; Ruth, Michael J.

    2016-02-16

    A gaseous reductant injection and mixing system is described herein. The system includes an injector for injecting a gaseous reductant into an exhaust gas stream, and a mixer attached to a surface of the injector. The injector includes a plurality of apertures through which the gaseous reductant is injected into an exhaust gas stream. The mixer includes a plurality of fluid deflecting elements.

  10. Sericin/Dextran Injectable Hydrogel as an Optically Trackable Drug Delivery System for Malignant Melanoma Treatment.

    PubMed

    Liu, Jia; Qi, Chao; Tao, Kaixiong; Zhang, Jinxiang; Zhang, Jian; Xu, Luming; Jiang, Xulin; Zhang, Yunti; Huang, Lei; Li, Qilin; Xie, Hongjian; Gao, Jinbo; Shuai, Xiaoming; Wang, Guobin; Wang, Zheng; Wang, Lin

    2016-03-01

    Severe side effects of cancer chemotherapy prompt developing better drug delivery systems. Injectable hydrogels are an effective site-target system. For most of injectable hydrogels, once delivered in vivo, some properties including drug release and degradation, which are critical to chemotherapeutic effects and safety, are challenging to monitor. Developing a drug delivery system for effective cancer therapy with in vivo real-time noninvasive trackability is highly desired. Although fluorescence dyes are used for imaging hydrogels, the cytotoxicity limits their applications. By using sericin, a natural photoluminescent protein from silk, we successfully synthesized a hydrazone cross-linked sericin/dextran injectable hydrogel. This hydrogel is biodegradable and biocompatible. It achieves efficient drug loading and controlled release of both macromolecular and small molecular drugs. Notably, sericin's photoluminescence from this hydrogel is directly and stably correlated with its degradation, enabling long-term in vivo imaging and real-time monitoring of the remaining drug. The hydrogel loaded with Doxorubicin significantly suppresses tumor growth. Together, the work demonstrates the efficacy of this drug delivery system, and the in vivo effectiveness of this sericin-based optical monitoring strategy, providing a potential approach for improving hydrogel design toward optimal efficiency and safety of chemotherapies, which may be widely applicable to other drug delivery systems.

  11. A New Partial Reconfiguration-Based Fault-Injection System to Evaluate SEU Effects in SRAM-Based FPGAs

    NASA Astrophysics Data System (ADS)

    Sterpone, L.; Violante, M.

    2007-08-01

    Modern SRAM-based field programmable gate array (FPGA) devices offer high capability in implementing complex system. Unfortunately, SRAM-based FPGAs are extremely sensitive to single event upsets (SEUs) induced by radiation particles. In order to successfully deploy safety- or mission-critical applications, designer need to validate the correctness of the obtained designs. In this paper we describe a system based on partial-reconfiguration for running fault-injection experiments within the configuration memory of SRAM-based FPGAs. The proposed fault-injection system uses the internal configuration capabilities that modern FPGAs offer in order to inject SEU within the configuration memory. Detailed experimental results show that the technique is orders of magnitude faster than previously proposed ones.

  12. [Efficacy and safety of Danhong injection for idiopathic pulmonary fibrosis:Meta-analysis].

    PubMed

    Xin, Li-Li; Jiang, Miao; Zhang, Geng; Gong, Jie-Ning

    2016-10-01

    To systematically review the efficacy and safety of Danhong injection for patients with idiopathic pulmonary fibrosis(IPF), two researchers electronically searched PubMed, EMbase, Web of Science, Cochrane Library, CNKI, CBM, WanFang Data and VIP databases from the date of establishment to May 2016 for all randomized controlled trials(RCTs) and quasi-RCTs on the use of Danhong injection in patients with IPF. Manual search in relevant journals and search of relevant literature on other websites were also performed. The data extraction and quality assessment of included RCTs and quasi-RCT were conducted by two reviewers independently. Then, Meta-analysis was conducted by using RevMan 5.3 software. A total of 12 RCTs involving 844 patients were included, 423 cases in experiment group and 421 cases in control group. The results of meta-analysis indicated that the Danhong injection group was superior than the control group in clinical effectiveness(RR=1.36, 95%CI 1.25 to 1.49, P<0.000 01), increased DLCO value(MD=4.25, 95%CI 3.32 to 5.18, P<0.000 01), and increased PaO2 value(MD=14.51, 95%CI 12.35 to 16.68, P<0.000 01). The analysis results showed that Danhong injection could significantly reduce the level of TGF-β1 in serum. There were no serious or frequently happened adverse effects in the Danhong injection group, indicating high safety and good tolerance of Danhong injection in treatment of IPF. The current evidences suggested that Danhong injection in short term use(<12 weeks) could increase clinical effectiveness, improve DLCO and PaO2, and decrease the level of TGF-β1 in serum of IPF patients, with less adverse effects. However, these results should be carefully interpreted due to the low methodology quality and small sample size of trials, and this conclusion had to be further verified by high quality, large scale and double blinded RCTs. Copyright© by the Chinese Pharmaceutical Association.

  13. Reevaluation of the post-marketing safety of Shuxuening injection based on real-world and evidence-based evaluations.

    PubMed

    Wang, Can; Shi, Qing-Ping; Ding, Feng; Jiang, Xiao-Dong; Tang, Wei; Yu, Mei-Ling; Zhu, Jian-Hua

    2018-01-01

    To evaluate the factors influencing suspected hypersensitivity and adverse systemic reactions after Shuxuening injection and to provide innovative ideas and methods for the reevaluation of post-marketing safety of Shuxuening. This study used a prospective, nested case-control study design, combined with a prescription sequence analysis design method. It classified patients who exhibited trigger signals after administration of Shuxuening injection as suspected allergic patients and made comparisons with patients who did not report adverse effects to calculate the correlation between relevant risk factors and suspected allergic reactions. Randomized controlled studies and cohort studies of the adverse drug reaction (ADR) of Shuxuening were performed using a computer database. Data retrieval was carried out by the foundation governing the individual database. Meta-analysis was performed by using R3.2.3 software to evaluate the ADRs of Shuxuening. The results of real-world study showed that administration of Shuxuening in combination with potassium aspartate and magnesium, atorvastatin calcium, Shengmai injection, pantoprazole sodium, or high-dose medication was a risk factor for suspected allergic reactions. Meta-analysis showed that the incidence of adverse events was 5.84% (95% CI 0.0499; 0.0674), and serious adverse reaction rate was 4.36% (95% CI 0.0188; 0.0760) when Shuxuening was used in combination with these drugs. The incidence of allergic reaction was also influenced by the vehicle, duration of treatment, single dose, and indicated vs off-label use. Risk factors for adverse reaction following the use of Shuxuening injection in patients are associated with a single dose, vehicle, type of disease, and combination with potassium aspartate, atorvastatin calcium, Shengmai injection, injection with pantoprazole sodium, and other drugs. Physicians should be careful to follow guidelines when administering this drug. We further propose that the unique methodology

  14. A System for Integrated Reliability and Safety Analyses

    NASA Technical Reports Server (NTRS)

    Kostiuk, Peter; Shapiro, Gerald; Hanson, Dave; Kolitz, Stephan; Leong, Frank; Rosch, Gene; Coumeri, Marc; Scheidler, Peter, Jr.; Bonesteel, Charles

    1999-01-01

    We present an integrated reliability and aviation safety analysis tool. The reliability models for selected infrastructure components of the air traffic control system are described. The results of this model are used to evaluate the likelihood of seeing outcomes predicted by simulations with failures injected. We discuss the design of the simulation model, and the user interface to the integrated toolset.

  15. Design optimisation of a nanofluid injection system for LOCA events in a nuclear power plant

    NASA Astrophysics Data System (ADS)

    Călimănescu, I.; Stan, L. C.; Velcea, D. D.

    2016-08-01

    The safety issues inside a Nuclear Power Plant (NPP) are encompassing their capacity to ensure the heat sink, meaning the capacity of the systems to release the heat from the rector to the environment. The nanofluids having good heat transfer properties, are recommended to be used in such applications. The paper is solving the following scenario: considering the Safety Injection tank and the Nanofluid injection Tank, and considering the Nanofluid injection Tank filled with a 10% alumina-water nanofluid, how can we select the best design of the connecting point between the pipes of the SIT and the Nanofluid Tank and the pressures inside of any of these tanks in order to have the biggest density of nanoparticles leaving the tanks toward the cold leg. In conclusion the biggest influence over the rate of disposal of the nanofluid inside ECCS is that of the pressure inside the SIT followed in order by the injection pipe diameter and the pressure inside the nanofluid tank. The optimum balance of these three design parameters may be reached following the procedure shown in this paper.

  16. [Strategy of constructing post-market integral evaluation system of traditional Chinese medicine injection].

    PubMed

    Zhang, Xiao-Yu; Wang, Yan-Ping; Lin, Li-Kai; Shang, Hong-Cai; Wang, Yong-Yan

    2017-08-01

    As an important representative of modern Chinese medicine, traditional Chinese medicine (TCM) injzection has become an indispensable part of the Chinese medicine industry. However, its development is now restricted by the bottleneck of insufficient core competitiveness, low-level research and production, even injection quality and the safe use are not guaranteed. Thus, it is urgent to reevaluate post-marketing TCM injection generally and to make secondary development. Under current circumstances, taking major brands which have good clinical and market foundation, as well as research value, as the main subject of cultivation and evaluation is an important approach to innovative development of TCM injection industry. Unlike oral proprietary Chinese medicine, the cultivatation of major brands of TCM injection needs higher technical support, quality standards and more timely feedback. Therefore, a post-market integral evaluation system adaptive to TCM injection is required. This article discussed some key points on the construction of a post-market integral evaluation system of TCM injection in three levels: optimizing evaluation methods, building synergistic innovation platforms which combine the medical research institutions and pharmaceutical enterprises, and finally constructing the integral evaluation system. A "five to one" structure has been proposed to enhance TCM injection effectiveness, safety and adaptability on the whole, which are from the following aspects: mechanism research, clinical evidence validation, literature information mining, sustainable development of resources and industrialization operation. Copyright© by the Chinese Pharmaceutical Association.

  17. Deltoid Injections of Risperidone Long-acting Injectable in Patients with Schizophrenia

    PubMed Central

    Quiroz, Jorge A.; Rusch, Sarah; Thyssen, An; Kushner, Stuart

    2011-01-01

    Background Risperidone long-acting injectable was previously approved for treatment of schizophrenia as biweekly injections in the gluteal muscle only. We present data on local injection-site tolerability and safety of risperidone long-acting injectable and comparability of systemic exposure of deltoid versus gluteal injections. Methods Risperidone long-acting injectable was administered in an open-label, single-dose, two-way crossover study, with patients randomized to receive either 25mg gluteal/37.5mg deltoid crossover in two treatment periods or 50mg gluteal/50mg deltoid injections crossover; each treatment period was separated by an 85-day observation period (Study 1) and an open-label, multiple-dose study (4 sequential 37.5mg or 50mg deltoid injections every 2 weeks) (Study 2). The pharmacokinetic results from both the studies have already been published. Results In Study 1 (n=170), the majority of patients had no local injection-site findings, based on investigator and patient-rated evaluations. In Study 2 (n=53), seven of the 51 patients who received at least two deltoid injections discontinued (primary endpoint). However, none of the discontinuations were due to injection-site related reasons. The 90-percent upper confidence limit of the true proportion of injection-site issue withdrawals was 5.7 percent. No moderate or severe injection-site reactions were reported. Conclusion Intramuscular injections via the deltoid and gluteal sites are equivalent routes of administration of risperidone long-acting injectable with respect to local injection-site tolerability. The overall safety and tolerability profile of risperidone long-acting injectable was comparable when administered as an intramuscular injection in the deltoid (37.5mg and 50mg) and gluteal (25mg and 50mg) sites. PMID:21779538

  18. Strategies for safe injections.

    PubMed Central

    Battersby, A.; Feilden, R.; Stoeckel, P.; Da Silva, A.; Nelson, C.; Bass, A.

    1999-01-01

    In 1998, faced with growing international concern, WHO set out an approach for achieving injection safety that encompassed all elements from patients' expectations and doctors' prescribing habits to waste disposal. This article follows that lead and describes the implications of the approach for two injection technologies: sterilizable and disposable. It argues that focusing on any single technology diverts attention from the more fundamental need for health services to develop their own comprehensive strategies for safe injections. National health authorities will only be able to ensure that injections are administered safely if they take an approach that encompasses the whole system, and choose injection technologies that fit their circumstances. PMID:10680247

  19. Induced seismicity closed-form traffic light system for actuarial decision-making during deep fluid injections.

    PubMed

    Mignan, A; Broccardo, M; Wiemer, S; Giardini, D

    2017-10-19

    The rise in the frequency of anthropogenic earthquakes due to deep fluid injections is posing serious economic, societal, and legal challenges to many geo-energy and waste-disposal projects. Existing tools to assess such problems are still inherently heuristic and mostly based on expert elicitation (so-called clinical judgment). We propose, as a complementary approach, an adaptive traffic light system (ATLS) that is function of a statistical model of induced seismicity. It offers an actuarial judgement of the risk, which is based on a mapping between earthquake magnitude and risk. Using data from six underground reservoir stimulation experiments, mostly from Enhanced Geothermal Systems, we illustrate how such a data-driven adaptive forecasting system could guarantee a risk-based safety target. The proposed model, which includes a linear relationship between seismicity rate and flow rate, as well as a normal diffusion process for post-injection, is first confirmed to be representative of the data. Being integrable, the model yields a closed-form ATLS solution that is both transparent and robust. Although simulations verify that the safety target is consistently ensured when the ATLS is applied, the model from which simulations are generated is validated on a limited dataset, hence still requiring further tests in additional fluid injection environments.

  20. Dual fuel injection piggyback controller system

    NASA Astrophysics Data System (ADS)

    Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim

    2017-09-01

    Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.

  1. Capsule injection system for a hydraulic capsule pipelining system

    DOEpatents

    Liu, Henry

    1982-01-01

    An injection system for injecting capsules into a hydraulic capsule pipelining system, the pipelining system comprising a pipeline adapted for flow of a carrier liquid therethrough, and capsules adapted to be transported through the pipeline by the carrier liquid flowing through the pipeline. The injection system comprises a reservoir of carrier liquid, the pipeline extending within the reservoir and extending downstream out of the reservoir, and a magazine in the reservoir for holding capsules in a series, one above another, for injection into the pipeline in the reservoir. The magazine has a lower end in communication with the pipeline in the reservoir for delivery of capsules from the magazine into the pipeline.

  2. [Pharmacokinetics and safety of aripiprazole long-acting injection, following multiple deltoid administrations in schizophrenia patients in Japan].

    PubMed

    Ishigooka, Jun; Noda, Takamasa; Nishiyama, Kosuke; Tamaru, Noriko; Shima, Tomoko; Yamasaki, Yumiko; Tadori, Yoshihiro

    2016-06-01

    Aripiprazole once-monthly (AOM) was previously approved for treatment of schizophrenia as monthly injections in the gluteal muscle. The deltoid muscle provides a more accessible injection site. The present study was conducted in Japanese schizophrenia patients as a 24-week, open-label trial that assessed the pharmacokinetics and safety of 5 sequential doses of AOM 400 mg (AOM 400) once every 4 weeks administered in the deltoid muscle. Patients treated with an oral atypical antipsychotic (other than aripiprazole) continued to receive their pre-study medication up to 14 days after the first AOM 400 injection. The completion rate was 76.5% (n = 13/17). Mean aripiprazole plasma C(min) almost reached steady-state by the fourth AOM 400 injection. After the fifth AOM 400 injection, mean aripiprazole AUC(28d), C(max) and C(min) were 165 μg x h/ml, 331 ng/ml and 201 ng/ml, respectively, which were similar to previously published pharmacokinetic parameters after the fifth gluteal injection of AOM 400. The most common treatment-emergent adverse event (TEAE) was injection site pain (35.3%). Most TEAEs were classified as mild in intensity. In conclusion, the deltoid injection of AOM can be considered an alternative route of administration, as deltoid and gluteal injections are interchangeable in terms of aripiprazole plasma concentrations, with no additional safety issues.

  3. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  4. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  5. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  6. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  7. 30 CFR 36.22 - Fuel-injection system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuel-injection system. 36.22 Section 36.22... EQUIPMENT Construction and Design Requirements § 36.22 Fuel-injection system. This system shall be so.... Provision shall be made for convenient adjustment of the maximum fuel-injection rate to that required for...

  8. A volumetric flow sensor for automotive injection systems

    NASA Astrophysics Data System (ADS)

    Schmid, U.; Krötz, G.; Schmitt-Landsiedel, D.

    2008-04-01

    For further optimization of the automotive power train of diesel engines, advanced combustion processes require a highly flexible injection system, provided e.g. by the common rail (CR) injection technique. In the past, the feasibility to implement injection nozzle volumetric flow sensors based on the thermo-resistive measurement principle has been demonstrated up to injection pressures of 135 MPa (1350 bar). To evaluate the transient behaviour of the system-integrated flow sensors as well as an injection amount indicator used as a reference method, hydraulic simulations on the system level are performed for a CR injection system. Experimentally determined injection timings were found to be in good agreement with calculated values, especially for the novel sensing element which is directly implemented into the hydraulic system. For the first time pressure oscillations occurring after termination of the injection pulse, predicted theoretically, could be verified directly in the nozzle. In addition, the injected amount of fuel is monitored with the highest resolution ever reported in the literature.

  9. Development of CNG direct injection (CNGDI) clean fuel system for extra power in small engine

    NASA Astrophysics Data System (ADS)

    Ali, Yusoff; Shamsudeen, Azhari; Abdullah, Shahrir; Mahmood, Wan Mohd Faizal Wan

    2012-06-01

    A new design of fuel system for CNG engine with direct injection (CNGDI) was developed for a demonstration project. The development of the fuel system was done on the engine with cylinder head modifications, for fuel injector and spark plug openings included in the new cylinder head. The piston was also redesigned for higher compression ratio. The fuel rails and the regulators are also designed for the direct injection system operating at higher pressure about 2.0 MPa. The control of the injection timing for the direct injectors are also controlled by the Electronic Control Unit specially designed for DI by another group project. The injectors are selected after testing with the various injection pressures and spray angles. For the best performance of the high-pressure system, selection is made from the tests on single cylinder research engine (SCRE). The components in the fuel system have to be of higher quality and complied with codes and standards to secure the safety of engine for high-pressure operation. The results of the CNGDI have shown that better power output is produced and better emissions were achieved compared to the aspirated CNG engine.

  10. An Innovative Needle-free Injection System: Comparison to 1 ml Standard Subcutaneous Injection.

    PubMed

    Kojic, Nikola; Goyal, Pragun; Lou, Cheryl Hamer; Corwin, Michael J

    2017-11-01

    A needle-free delivery system may lead to improved satisfaction and compliance, as well as reduced anxiety among patients requiring frequent or ongoing injections. This report describes a first-in-man assessment comparing Portal Instruments' innovative needle-free injection system with subcutaneous injections using a 27G needle. Forty healthy volunteer participants each received a total of four injections of 1.0 mL sterile saline solution, two with a standard subcutaneous injection using a 27G needle, and two using the Portal injection system. Perception of pain was measured using a 100-mm visual analog scale (VAS). Injection site reactions were assessed at 2 min and at 20-30 min after each injection. Follow-up contact was made 24-48 h after the injections. Subject preference regarding injection type was also assessed. VAS pain scores at Portal injection sites met the criteria to be considered non-inferior to the pain reported at 27G needle injection sites (i.e., upper 95% confidence bound less than +5 mm). Based on a mixed effects model, at time 0, accounting for potential confounding variables, the adjusted difference in VAS scores indicated that Portal injections were 6.5 mm lower than the 27G needle injections (95% CI -10.5, -2.5). No clinically important adverse events were noted. Portal injections were preferred by 24 (60%) of the subjects (P = 0.0015). As an early step in the development of this new needle-free delivery system, the current study has shown that a 1.0-mL saline injection can be given with less pain reported than a standard subcutaneous injection using a 27G needle.

  11. Knowledge, attitudes, beliefs, values, preferences, and feasibility in relation to the use of injection safety devices in healthcare settings: a systematic review.

    PubMed

    Tarabay, Rami; El Rassi, Rola; Dakik, Abeer; Harb, Alain; Ballout, Rami A; Diab, Batoul; Khamassi, Selma; Akl, Elie A

    2016-07-13

    Adopting technologies such as injection safety devices in healthcare settings can enhance injection safety. Developing guidelines for appropriate adoption of such technologies need to consider factors beyond evidence for their health effects. The objective of this study is to systematically review the published literature for evidence among healthcare workers and patients about knowledge, attitudes, beliefs, values, preferences, and feasibility in relation to the use of injection safety devices in healthcare settings. We included both qualitative and quantitative studies conducted with the general public, patients, and healthcare workers, administrators, or policy makers. We searched MEDLINE, EMBASE, CINHAL and CENTRAL. We used a duplicate and independent approach to title and abstract screening, full text screening, data abstraction and risk of bias assessment. Out of a total of 6568 identified citations, we judged fourteen studies as eligible for this systematic review. All these studies were surveys, conducted with healthcare workers in high-income countries. We did not identify any qualitative study, or a study of the general public, patients, healthcare administrators or policy makers. We did not identify any study assessing knowledge, or values assigned to outcomes relevant to injection safety devices. Each of the included studies suffered from methodological limitations, which lowers our confidence in their findings. Based on the findings of six studies, the injection safety devices were generally perceived as easy to use and as an improvement compared with conventional syringes. Some of these studies reported few technical problems while using the devices. In three studies assessing perceived safety, the majority of participants judged the devices as safe. Two studies reported positive perceptions of healthcare workers regarding patient tolerance of these injection safety devices. One study found that less than half the nurses felt comfortable using the

  12. Westinghouse Small Modular Reactor passive safety system response to postulated events

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M. C.; Wright, R. F.

    2012-07-01

    The Westinghouse Small Modular Reactor (SMR) is an 800 MWt (>225 MWe) integral pressurized water reactor. This paper is part of a series of four describing the design and safety features of the Westinghouse SMR. This paper focuses in particular upon the passive safety features and the safety system response of the Westinghouse SMR. The Westinghouse SMR design incorporates many features to minimize the effects of, and in some cases eliminates the possibility of postulated accidents. The small size of the reactor and the low power density limits the potential consequences of an accident relative to a large plant. Themore » integral design eliminates large loop piping, which significantly reduces the flow area of postulated loss of coolant accidents (LOCAs). The Westinghouse SMR containment is a high-pressure, compact design that normally operates at a partial vacuum. This facilitates heat removal from the containment during LOCA events. The containment is submerged in water which also aides the heat removal and provides an additional radionuclide filter. The Westinghouse SMR safety system design is passive, is based largely on the passive safety systems used in the AP1000{sup R} reactor, and provides mitigation of all design basis accidents without the need for AC electrical power for a period of seven days. Frequent faults, such as reactivity insertion events and loss of power events, are protected by first shutting down the nuclear reaction by inserting control rods, then providing cold, borated water through a passive, buoyancy-driven flow. Decay heat removal is provided using a layered approach that includes the passive removal of heat by the steam drum and independent passive heat removal system that transfers heat from the primary system to the environment. Less frequent faults such as loss of coolant accidents are mitigated by passive injection of a large quantity of water that is readily available inside containment. An automatic depressurization system is

  13. Safety of Lienal Polypeptide Injection Combined with Chemotherapy in Treating Patients with Advanced Cancer.

    PubMed

    Huang, Xin-En; Wang, Lin; Ji, Zhu-Qing; Liu, Meng-Yan; Qian, Ting; Li, Li

    2015-01-01

    To assess the safety of Liena polypeptide injection (produced by JILIN FSENS PHARMACEUTICAL CO.,LTD) combined with chemotherapy in treating patients with advanced cancers. A consecutive cohort of patients with advanced cancers were treated with Liena polypeptide injection combined with chemotherapy. And chemotherapy for patients with advanced cancers were adopted from regimens suggested by NCCN guideline. Liena polypeptide injection was intravenously injected at a dosage of 2 ml plus 100ml normal saline for continuous 7 days during chemotherapy as one course. After at least two courses of treatment, safety and side effects were evaluated. There were 20 female and 14 male patients with advanced cancer recruited into this study, including 10 patients with breast, 8 patients with colorectal, 8 patients with lung, 4 patients with gastric, and 1 patient with esophageal cancer, as well as 1 patient with non-Hodgkin's lymphoma, 1 patient with low pharyngeal and 1 patient with urethral cancer. The median age of patients was 59 (40-82) years. Incidences of Grade 1 to 2 myelosuppression was observed in 5/34 patients, and Grade 1 to 2 elevation of hepatic enzyme was recorded in 3/34 patients. Adverse effects on the gastrointestinal tract were documented in 5/34 patients, and were Grade 1. No Grade 3-4 toxicities were diagnosed. No treatment related death was found. Liena polypeptide injection combined with chemotherapy was safe in treating several sites of tumors, that mainly included lung, colorectal and breast cancer. However, further study should be conducted to clarify the effectiveness of this treatment.

  14. Safety and tolerability of injectable lipid-lowering drugs: a review of available clinical data.

    PubMed

    Cicero, Arrigo F G; Tartagni, Elisa; Ertek, Sibel

    2014-08-01

    To answer the need of a better low-density lipoprotein (LDL) cholesterol control in statin-treated patients at high risk for cardiovascular disease, new injectable lipid-lowering drugs with innovative mechanisms of action are in advanced phase of development or have just been approved. Evolocumab and alirocumab are fully human monoclonal antibodies inhibiting the proprotein convertase subtilisin/kexin type 9 (PCSK9) that binds to hepatic LDL receptor and prevents it from normal recycling by targeting it for degradation. Mipomersen specifically binds to a segment of the human apolipoprotein B100 messenger RNA, blocking the translation of the gene product. Phase II (for evolocumab and alirocumab) and III (for evolocumab) trials show that PCSK9 inhibitors are equally well tolerated, with adverse events mainly limited to mild-to-moderate nasopharyngitis, injection-site pain, arthralgia and back pain. Mipomersen use is mainly associated to hepatosteatosis, increased transaminases (> 3 times the upper limit of normal), mild-to-moderate injection-site reactions and flu-like symptoms. PCSK9 inhibitors have demonstrated their good safety and tolerability in a large number of subjects with different clinical conditions, including statin-intolerance, enlarging their potential use in a broader range of patients. Further data on long-term mipomersen safety are required.

  15. Safety and Efficacy of Permacol Injection in the Treatment of Fecal Incontinence.

    PubMed

    Al-Abed, Yahya A; Ayers, Jennifer; Ayantunde, Abraham; Praveen, Bandipalyam V

    2016-04-01

    Permacol has been gaining popularity in recent times for the treatment of fecal incontinence (FI). This study aims to evaluate the safety and efficacy of anal submucosal Permacol injection in the treatment of FI. All consecutive patients who underwent Permacol injection for FI over a 3-year period were included. Patients' data relating to obstetric history, anorectal/pelvic operations, type of FI, preoperative anorectal physiology results and follow-up details for outcome measures were collected. Preoperative and postoperative Cleveland Clinic Florida Incontinence Scores (CCFISs) were noted. Patients were surveyed by using a telephone questionnaire to assess the quality of life and other outcome measures. Data were analysed using SPSS ver.19.0. Thirty patients (28 females and 2 males) with a median age of 67 years were included in the study. Of those patients, 37%, 50%, and 13% were noted to have passive, mixed and urge FI, respectively. Six of the patients (20%) had repeat Permacol injections, 5 of whom had sustained responses to the first Permacol injection for a mean of 11 months. There was a significant improvement in the CCFIS from a baseline median of 12.5, mean 12.8 interquartile range [IQR], 6-20), to a median of 3.5, mean 4.8 (IQR, 0-20), P < 0.001. Of the patients surveyed by telephone 89% were satisfied with their overall experience and the improvement in their symptoms following Permacol injections. This study has demonstrated that Permacol injection for the treatment of FI is safe and effective and has no associated major complications. However, the results are not permanent; consequently, a significant proportion of the patients with an initial response may require repeat injections.

  16. Postmarketing Safety Surveillance and Reevaluation of Danhong Injection: Clinical Study of 30888 Cases

    PubMed Central

    Li, Xue-Lin; Tang, Jin-Fa; Li, Wei-Xia; Li, Chun-Xiao; Zhao, Tao; Zhao, Bu-Chang; Wang, Yong; Zhang, Hui; Chen, Xiao-Fei; Xu, Tao; Zhu, Ming-Jun

    2015-01-01

    Traditional Chinese medicine injections (TCMIs) have played an irreplaceable role for treating some clinical emergency, severe illness, and infectious diseases in China. In recent years, the incidence rates of adverse drug reactions (ADRs) of TCMIs have increased year by year. Danhong injection (DHI) is one representative TCMI comprised of Danshen and Honghua for treating cardiovascular and cerebrovascular diseases in clinic. In present study, the postmarketing safety surveillance and reevaluation of DHI were reported. Total 30888 patients in 37 hospitals from 6 provinces participated in the study. The results showed that the ADR incidence rate of DHI was 3.50‰. Seventeen kinds of new adverse reactions of DHI were found. The main type of ADRs of DHI was type A (including sweating, dizziness, headache, flushing, vasodilation, eye hemorrhage, faintness, chest pain, palpitations, breathlessness, anxious, nausea, flatulence, vomiting, hypotension, hypertension, local numbness, dyspnea, joint disease, and tinnitus) accounting for 57.75%. The severities of most ADRs of DHI were mild and moderate reactions accounting for 25.93% and 66.67%, respectively. The main disposition of ADRs of DHI was drug withdrawal and without any treatments. The results can provide basis for amendment and improvement of the instructions of DHI, as well as demonstration and reference for the postmarketing safety surveillance and reevaluation of other TCMIs. And the rationality, scientificity, and safety of clinical applications of TCMIs could be improved. PMID:26508981

  17. Poly(ortho ester) nanoparticles targeted for chronic intraocular diseases: ocular safety and localization after intravitreal injection.

    PubMed

    Li, Huiling; Palamoor, Mallika; Jablonski, Monica M

    2016-10-01

    Treatment of posterior eye diseases is more challenging than the anterior segment ailments due to a series of anatomical barriers and physiological constraints confronted by drug delivery to the back of the eye. In recent years, concerted efforts in drug delivery have been made to prolong the residence time of drugs injected in the vitreous humor of the eye. Our previous studies demonstrated that poly(ortho ester) (POE) nanoparticles were biodegradable/biocompatible and were capable of long-term sustained release. The objective of the present study was to investigate the safety and localization of POE nanoparticles in New Zealand white rabbits and C57BL/6 mice after intravitreal administration for the treatment of chronic posterior ocular diseases. Two concentration levels of POE nanoparticles solution were chosen for intravitreal injection: 1.5 mg/ml and 10 mg/ml. Our results demonstrate that POE nanoparticles were distributed throughout the vitreous cavity by optical coherence tomography (OCT) examination 14 days post-intravitreal injection. Intraocular pressure was not changed from baseline. Inflammatory or adverse effects were undetectable by slit lamp biomicroscopy. Furthermore, we demonstrate that POE nanoparticles have negligible toxicity assessed at the cellular level evidenced by a lack of glia activation or apoptosis estimation after intravitreal injection. Collectively, POE nanoparticles are a novel and nontoxic as an ocular drug delivery system for the treatment of posterior ocular diseases.

  18. Economics of water injected air screw compressor systems

    NASA Astrophysics Data System (ADS)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  19. System safety education focused on flight safety

    NASA Technical Reports Server (NTRS)

    Holt, E.

    1971-01-01

    The measures necessary for achieving higher levels of system safety are analyzed with an eye toward maintaining the combat capability of the Air Force. Several education courses were provided for personnel involved in safety management. Data include: (1) Flight Safety Officer Course, (2) Advanced Safety Program Management, (3) Fundamentals of System Safety, and (4) Quantitative Methods of Safety Analysis.

  20. Prevalence of injections and knowledge of safe injections among rural residents in Central China.

    PubMed

    Yan, Y W; Yan, J; Zhang, G P; Gao, Z L; Jian, H X

    2007-08-01

    Abuse of the injection services, namely unnecessary injections and unsafe injections, exists extensively in developing countries. Unsafe injection practices contribute to the transmission of blood-borne pathogens. The aims of this study were to survey the prevalence of injections and knowledge of injection safety among the rural residents in Jingzhou district, Hubei, China and to provide scientific data for developing a health educational programme. A retrospective cross-sectional study was conducted in 12 villages, which were selected from the Jingzhou district by the random sampling method. 50 rural residents were interviewed per village using a questionnaire. Among the 595 residents studied, 192 had received at least one injection in the past three months, with an injection prevalence of 32.3 percent and an average of 0.93 injections. 90.3 percent of the rural residents knew that unsafe injections could transmit the following blood-borne pathogens: human immunodeficiency virus (74.4 percent), hepatitis B virus (55.8 percent) and hepatitis C virus (22.9 percent). Logistic regression analysis showed that the residents' age, educational level and residential area were important factors in influencing their knowledge about injection safety. The results indicated that the injection prevalence was high among rural residents in the study area, and their knowledge regarding injection safety should be further improved.

  1. Active waste-injection systems in Florida, 1976

    USGS Publications Warehouse

    Vecchioli, John; McKenzie, D.J.; Pascale, C.A.; Wilson, W.E.

    1979-01-01

    As of the end of 1976, seven systems were injecting liquid wastes into Florida 's subsurface environment at a combined average rate of 15 million gallons per day. This report presents for each of these systems information on the kind and amount of waste injected and type of pretreatment, construction characteristics of the injection and monitor wells, type of test and monitoring data available, and brief discussion of any operational problems experienced. (Kosco-USGS)

  2. Safety and Efficacy of Permacol Injection in the Treatment of Fecal Incontinence

    PubMed Central

    Ayers, Jennifer; Ayantunde, Abraham; Praveen, Bandipalyam V

    2016-01-01

    Purpose Permacol has been gaining popularity in recent times for the treatment of fecal incontinence (FI). This study aims to evaluate the safety and efficacy of anal submucosal Permacol injection in the treatment of FI. Methods All consecutive patients who underwent Permacol injection for FI over a 3-year period were included. Patients' data relating to obstetric history, anorectal/pelvic operations, type of FI, preoperative anorectal physiology results and follow-up details for outcome measures were collected. Preoperative and postoperative Cleveland Clinic Florida Incontinence Scores (CCFISs) were noted. Patients were surveyed by using a telephone questionnaire to assess the quality of life and other outcome measures. Data were analysed using SPSS ver.19.0. Results Thirty patients (28 females and 2 males) with a median age of 67 years were included in the study. Of those patients, 37%, 50%, and 13% were noted to have passive, mixed and urge FI, respectively. Six of the patients (20%) had repeat Permacol injections, 5 of whom had sustained responses to the first Permacol injection for a mean of 11 months. There was a significant improvement in the CCFIS from a baseline median of 12.5, mean 12.8 interquartile range [IQR], 6–20), to a median of 3.5, mean 4.8 (IQR, 0–20), P < 0.001. Of the patients surveyed by telephone 89% were satisfied with their overall experience and the improvement in their symptoms following Permacol injections. Conclusion This study has demonstrated that Permacol injection for the treatment of FI is safe and effective and has no associated major complications. However, the results are not permanent; consequently, a significant proportion of the patients with an initial response may require repeat injections. PMID:27218098

  3. Efficacy and safety of acute injection laryngoplasty for vocal cord paralysis following thoracic surgery.

    PubMed

    Graboyes, Evan M; Bradley, Joseph P; Meyers, Bryan F; Nussenbaum, Brian

    2011-11-01

    The primary objective of this study was to evaluate the effectiveness and safety of injection laryngoplasty using a temporary injectable agent in the acute setting for patients with unilateral vocal cord paralysis following thoracic surgical procedures. Retrospective consecutive case series in an academic institution. Inclusion criteria included patients acutely treated with injection laryngoplasty from January 1, 2006, to March 31, 2010, for a unilateral vocal cord paralysis that occurred after a thoracic surgical procedure (N = 20). All patients were injected with Radiesse Voice Gel using microlaryngoscopy technique. The mean time to vocal cord injection from the time of thoracic surgery was 4.5 days. There was one operative-related complication of intraoperative bile reflux that caused a pneumonitis. Ninety percent of patients were recommended for strict nothing by mouth prior to injection. Of these, 94% were allowed an oral diet following injection, and 67% tolerated a regular diet. None of the patients required subsequent procedures for aspiration or dysphagia, and 25% required further intervention after discharge for persistent dysphonia. Patients with a known nerve transection had a higher rate of dysphonia requiring further surgical procedures than those who did not have a known nerve transection. Acute treatment of thoracic surgery-related unilateral vocal cord paralysis with injection laryngoplasty appears safe and effective at preventing postoperative aspiration pneumonia and improves swallowing function to allow resumption of an oral diet. A single injection is often the only required treatment. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  4. Material Gradients in Oxygen System Components Improve Safety

    NASA Technical Reports Server (NTRS)

    Forsyth, Bradley S.

    2011-01-01

    Oxygen system components fabricated by Laser Engineered Net Shaping (TradeMark) (LENS(TradeMark)) could result in improved safety and performance. LENS(TradeMark) is a near-net shape manufacturing process fusing powdered materials injected into a laser beam. Parts can be fabricated with a variety of elemental metals, alloys, and nonmetallic materials without the use of a mold. The LENS(TradeMark) process allows the injected materials to be varied throughout a single workpiece. Hence, surfaces exposed to oxygen could be constructed of an oxygen-compatible material while the remainder of the part could be one chosen for strength or reduced weight. Unlike conventional coating applications, a compositional gradient would exist between the two materials, so no abrupt material boundary exists. Without an interface between dissimilar materials, there is less tendency for chipping or cracking associated with thermal-expansion mismatches.

  5. Epidural Steroid Injections are Safe and Effective: Multisociety Letter in Support of the Safety and Effectiveness of Epidural Steroid Injections.

    PubMed

    Kennedy, David J; Levin, Joshua; Rosenquist, Richard; Singh, Virtaj; Smith, Clark; Stojanovic, Milan P; Vorobeychik, Yakov

    2015-05-01

    In April 2014, the Food and Drug Administration (FDA) issued a Drug Safety Communication requesting that corticosteroid labeling include warnings that injection of corticosteroids into the epidural space of the spine may result in rare but serious adverse events, including loss of vision, stroke, paralysis, and death. The International Spine Intervention Society spearheaded a collaboration of more than a dozen other medical societies in submitting the letter below to the FDA on November 7, 2014. We are publishing the letter to ensure that the readership of Pain Medicine is aware of the multisociety support for the safety and effectiveness of these procedures. A special note of thanks to all of the societies who signed on in support of the message. Wiley Periodicals, Inc.

  6. Safety evaluation of poly(lactic-co-glycolic acid)/poly(lactic-acid) microspheres through intravitreal injection in rabbits.

    PubMed

    Rong, Xianfang; Yuan, Weien; Lu, Yi; Mo, Xiaofen

    2014-01-01

    Poly(lactic-co-glycolic acid) (PLGA) and/or poly(lactic-acid) (PLA) microspheres are important drug delivery systems. This study investigated eye biocompatibility and safety of PLGA/PLA microspheres through intravitreal injection in rabbits. Normal New Zealand rabbits were randomly selected and received intravitreal administration of different doses (low, medium, or high) of PLGA/PLA microspheres and erythropoietin-loaded PLGA/PLA microspheres. The animals were clinically examined and sacrificed at 1, 2, 4, 8, and 12 weeks postadministration, and retinal tissues were prepared for analysis. Retinal reactions to the microspheres were evaluated by terminal deoxynucleotidyl transferase-mediated dUTP nick end staining and glial fibrillary acidic protein immunohistochemistry. Retinal structure changes were assessed by hematoxylin and eosin staining and transmission electron microscopy. Finally, retinal function influences were explored by the electroretinography test. Terminal deoxynucleotidyl transferase-mediated dUTP nick end staining revealed no apoptotic cells in the injected retinas; immunohistochemistry did not detect any increased glial fibrillary acidic protein expression. Hematoxylin and eosin staining and transmission electron microscopy revealed no micro- or ultrastructure changes in the retinas at different time points postintravitreal injection. The electroretinography test showed no significant influence of scotopic or photopic amplitudes. The results demonstrated that PLGA/PLA microspheres did not cause retinal histological changes or functional damage and were biocompatible and safe enough for intravitreal injection in rabbits for controlled drug delivery.

  7. Software Safety Risk in Legacy Safety-Critical Computer Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.; Baggs, Rhoda

    2007-01-01

    Safety Standards contain technical and process-oriented safety requirements. Technical requirements are those such as "must work" and "must not work" functions in the system. Process-Oriented requirements are software engineering and safety management process requirements. Address the system perspective and some cover just software in the system > NASA-STD-8719.13B Software Safety Standard is the current standard of interest. NASA programs/projects will have their own set of safety requirements derived from the standard. Safety Cases: a) Documented demonstration that a system complies with the specified safety requirements. b) Evidence is gathered on the integrity of the system and put forward as an argued case. [Gardener (ed.)] c) Problems occur when trying to meet safety standards, and thus make retrospective safety cases, in legacy safety-critical computer systems.

  8. Software Safety Risk in Legacy Safety-Critical Computer Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice; Baggs, Rhoda

    2007-01-01

    Safety-critical computer systems must be engineered to meet system and software safety requirements. For legacy safety-critical computer systems, software safety requirements may not have been formally specified during development. When process-oriented software safety requirements are levied on a legacy system after the fact, where software development artifacts don't exist or are incomplete, the question becomes 'how can this be done?' The risks associated with only meeting certain software safety requirements in a legacy safety-critical computer system must be addressed should such systems be selected as candidates for reuse. This paper proposes a method for ascertaining formally, a software safety risk assessment, that provides measurements for software safety for legacy systems which may or may not have a suite of software engineering documentation that is now normally required. It relies upon the NASA Software Safety Standard, risk assessment methods based upon the Taxonomy-Based Questionnaire, and the application of reverse engineering CASE tools to produce original design documents for legacy systems.

  9. Miniaturized flow injection analysis system

    DOEpatents

    Folta, James A.

    1997-01-01

    A chemical analysis technique known as flow injection analysis, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38.times.25.times.3 mm, but can be designed for gas analysis and be substantially smaller in construction.

  10. Safety, tolerability and potential efficacy of injection of autologous adipose-derived stromal vascular fraction in the fingers of patients with systemic sclerosis: an open-label phase I trial.

    PubMed

    Granel, Brigitte; Daumas, Aurélie; Jouve, Elisabeth; Harlé, Jean-Robert; Nguyen, Pierre-Sébastien; Chabannon, Christian; Colavolpe, Nathalie; Reynier, Jean-Charles; Truillet, Romain; Mallet, Stéphanie; Baiada, Antoine; Casanova, Dominique; Giraudo, Laurent; Arnaud, Laurent; Veran, Julie; Sabatier, Florence; Magalon, Guy

    2015-12-01

    In patients with systemic sclerosis (scleroderma, SSc), impaired hand function greatly contributes to disability and reduced quality of life, and is insufficiently relieved by currently available therapies. Adipose tissue-derived stromal vascular fraction (SVF) is increasingly recognised as an easily accessible source of regenerative cells with therapeutic potential in ischaemic or autoimmune diseases. We aimed to measure for the first time the safety, tolerability and potential efficacy of autologous SVF cells local injections in patients with SSc with hand disability. We did an open-label, single arm, at one study site with 6-month follow-up among 12 female SSc patients with Cochin Hand Function Scale score >20/90. Autologous SVF was obtained from lipoaspirates, using an automated processing system, and subsequently injected into the subcutaneous tissue of each finger in contact with neurovascular pedicles. Primary outcome was the number and the severity of adverse events related to SVF-based therapy. Secondary endpoints were changes in hand disability and fibrosis, vascular manifestations, pain and quality of life from baseline to 2 and 6 months after cell therapy. All enrolled patients had surgery, and there were no dropouts or patients lost to follow-up. No severe adverse events occurred during the procedure and follow-up. Four minor adverse events were reported and resolved spontaneously. A significant improvement in hand disability and pain, Raynaud's phenomenon, finger oedema and quality of life was observed. This study outlines the safety of the autologous SVF cells injection in the hands of patients with SSc. Preliminary assessments at 6 months suggest potential efficacy needing confirmation in a randomised placebo-controlled trial on a larger population. GFRS (Groupe Francophone de Recherche sur la Sclérodermie). NCT01813279. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to

  11. Sodium storage and injection system

    NASA Technical Reports Server (NTRS)

    Keeton, A. R. (Inventor)

    1979-01-01

    A sodium storage and injection system for delivering atomized liquid sodium to a chemical reactor employed in the production of solar grade silicon is disclosed. The system is adapted to accommodate start-up, shut-down, normal and emergency operations, and is characterized by (1) a jacketed injection nozzle adapted to atomize liquefied sodium and (2) a supply circuit connected to the nozzle for delivering the liquefied sodium. The supply circuit is comprised of a plurality of replaceable sodium containment vessels, a pump interposed between the vessels and the nozzle, and a pressurizing circuit including a source of inert gas connected with the vessels for maintaining the sodium under pressure.

  12. Efficacy and Safety of an Injectable Combination Hormonal Contraceptive for Men.

    PubMed

    Behre, Hermann M; Zitzmann, Michael; Anderson, Richard A; Handelsman, David J; Lestari, Silvia W; McLachlan, Robert I; Meriggiola, M Cristina; Misro, Man Mohan; Noe, Gabriela; Wu, Frederick C W; Festin, Mario Philip R; Habib, Ndema A; Vogelsong, Kirsten M; Callahan, Marianne M; Linton, Kim A; Colvard, Doug S

    2016-12-01

    The development of a safe and effective reversible method of male contraception is still an unmet need. Evaluation of suppression of spermatogenesis and contraceptive protection by coadministered im injections of progestogen and testosterone. Prospective multicentre study. Ten study centers. Healthy men, aged 18-45 years, and their 18- to 38-year-old female partners, both without known fertility problems. Intramuscular injections of 200-mg norethisterone enanthate combined with 1000-mg testosterone undecanoate, administered every 8 weeks. Suppression of spermatogenesis by ejaculate analysis, contraceptive protection by pregnancy rate. Of the 320 participants, 95.9 of 100 continuing users (95% confidence interval [CI], 92.8-97.9) suppressed to a sperm concentration less than or equal to 1 million/mL within 24 weeks (Kaplan-Meier method). During the efficacy phase of up to 56 weeks, 4 pregnancies occurred among the partners of the 266 male participants, with the rate of 1.57 per 100 continuing users (95% CI, 0.59-4.14). The cumulative reversibility of suppression of spermatogenesis after 52 weeks of recovery was 94.8 per 100 continuing users (95% CI, 91.5-97.1). The most common adverse events were acne, injection site pain, increased libido, and mood disorders. Following the recommendation of an external safety review committee the recruitment and hormone injections were terminated early. The study regimen led to near-complete and reversible suppression of spermatogenesis. The contraceptive efficacy was relatively good compared with other reversible methods available for men. The frequencies of mild to moderate mood disorders were relatively high.

  13. NASA System Safety Handbook. Volume 2: System Safety Concepts, Guidelines, and Implementation Examples

    NASA Technical Reports Server (NTRS)

    Dezfuli, Homayoon; Benjamin, Allan; Everett, Christopher; Feather, Martin; Rutledge, Peter; Sen, Dev; Youngblood, Robert

    2015-01-01

    This is the second of two volumes that collectively comprise the NASA System Safety Handbook. Volume 1 (NASASP-210-580) was prepared for the purpose of presenting the overall framework for System Safety and for providing the general concepts needed to implement the framework. Volume 2 provides guidance for implementing these concepts as an integral part of systems engineering and risk management. This guidance addresses the following functional areas: 1.The development of objectives that collectively define adequate safety for a system, and the safety requirements derived from these objectives that are levied on the system. 2.The conduct of system safety activities, performed to meet the safety requirements, with specific emphasis on the conduct of integrated safety analysis (ISA) as a fundamental means by which systems engineering and risk management decisions are risk-informed. 3.The development of a risk-informed safety case (RISC) at major milestone reviews to argue that the systems safety objectives are satisfied (and therefore that the system is adequately safe). 4.The evaluation of the RISC (including supporting evidence) using a defined set of evaluation criteria, to assess the veracity of the claims made therein in order to support risk acceptance decisions.

  14. Safety and Efficacy of Intratumoral Injections of Chimeric Antigen Receptor (CAR) T Cells in Metastatic Breast Cancer.

    PubMed

    Tchou, Julia; Zhao, Yangbing; Levine, Bruce L; Zhang, Paul J; Davis, Megan M; Melenhorst, Jan Joseph; Kulikovskaya, Irina; Brennan, Andrea L; Liu, Xiaojun; Lacey, Simon F; Posey, Avery D; Williams, Austin D; So, Alycia; Conejo-Garcia, Jose R; Plesa, Gabriela; Young, Regina M; McGettigan, Shannon; Campbell, Jean; Pierce, Robert H; Matro, Jennifer M; DeMichele, Angela M; Clark, Amy S; Cooper, Laurence J; Schuchter, Lynn M; Vonderheide, Robert H; June, Carl H

    2017-12-01

    Chimeric antigen receptors (CAR) are synthetic molecules that provide new specificities to T cells. Although successful in treatment of hematologic malignancies, CAR T cells are ineffective for solid tumors to date. We found that the cell-surface molecule c-Met was expressed in ∼50% of breast tumors, prompting the construction of a CAR T cell specific for c-Met, which halted tumor growth in immune-incompetent mice with tumor xenografts. We then evaluated the safety and feasibility of treating metastatic breast cancer with intratumoral administration of mRNA-transfected c-Met-CAR T cells in a phase 0 clinical trial (NCT01837602). Introducing the CAR construct via mRNA ensured safety by limiting the nontumor cell effects (on-target/off-tumor) of targeting c-Met. Patients with metastatic breast cancer with accessible cutaneous or lymph node metastases received a single intratumoral injection of 3 × 10 7 or 3 × 10 8 cells. CAR T mRNA was detectable in peripheral blood and in the injected tumor tissues after intratumoral injection in 2 and 4 patients, respectively. mRNA c-Met-CAR T cell injections were well tolerated, as none of the patients had study drug-related adverse effects greater than grade 1. Tumors treated with intratumoral injected mRNA c-Met-CAR T cells were excised and analyzed by immunohistochemistry, revealing extensive tumor necrosis at the injection site, cellular debris, loss of c-Met immunoreactivity, all surrounded by macrophages at the leading edges and within necrotic zones. We conclude that intratumoral injections of mRNA c-Met-CAR T cells are well tolerated and evoke an inflammatory response within tumors. Cancer Immunol Res; 5(12); 1152-61. ©2017 AACR . ©2017 American Association for Cancer Research.

  15. Space engine safety system

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Meyer, Claudia M.

    1991-01-01

    A rocket engine safety system was designed to initiate control procedures to minimize damage to the engine or vehicle or test stand in the event of an engine failure. The features and the implementation issues associated with rocket engine safety systems are discussed, as well as the specific concerns of safety systems applied to a space-based engine and long duration space missions. Examples of safety system features and architectures are given, based on recent safety monitoring investigations conducted for the Space Shuttle Main Engine and for future liquid rocket engines. Also, the general design and implementation process for rocket engine safety systems is presented.

  16. Miniaturized flow injection analysis system

    DOEpatents

    Folta, J.A.

    1997-07-01

    A chemical analysis technique known as flow injection analysis is described, wherein small quantities of chemical reagents and sample are intermixed and reacted within a capillary flow system and the reaction products are detected optically, electrochemically, or by other means. A highly miniaturized version of a flow injection analysis system has been fabricated utilizing microfabrication techniques common to the microelectronics industry. The microflow system uses flow capillaries formed by etching microchannels in a silicon or glass wafer followed by bonding to another wafer, commercially available microvalves bonded directly to the microflow channels, and an optical absorption detector cell formed near the capillary outlet, with light being both delivered and collected with fiber optics. The microflow system is designed mainly for analysis of liquids and currently measures 38{times}25{times}3 mm, but can be designed for gas analysis and be substantially smaller in construction. 9 figs.

  17. Knowledge and Practice on Injection Safety among Primary Health Care Workers in Kaski District, Western Nepal

    PubMed Central

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, P Ravi; Kc, Vikash Kumar; Jha, Nisha; Sharma, Damodar

    2016-01-01

    Background Unsafe injection practice can transmit various blood borne infections. The aim of this study was to assess the knowledge and practice of injection safety among injection providers, to obtain information about disposal of injectable devices, and to compare the knowledge and practices of urban and rural injection providers. Methods The study was conducted with injection providers working at primary health care facilities within Kaski district, Nepal. Ninety-six health care workers from 69 primary health care facilities were studied and 132 injection events observed. A semi-structured checklist was used for observing injection practice and a questionnaire for the survey. Respondents were interviewed to complete the questionnaire and obtain possible explanations for certain observed behaviors. Results All injection providers knew of at least one pathogen transmitted through use/re-use of unsterile syringes. Proportion of injection providers naming hepatitis/jaundice as one of the diseases transmitted by unsafe injection practice was significantly higher in urban (75.6%) than in rural (39.2%) area. However, compared to urban respondents (13.3%), a significantly higher proportion of rural respondents (37.3%) named Hepatitis B specifically as one of the diseases transmitted. Median (inter-quartile range) number of therapeutic injection and injectable vaccine administered per day by the injection providers were 2 (1) and 1 (1), respectively. Two handed recapping by injection providers was significantly higher in urban area (33.3%) than in rural areas (21.6%). Most providers were not aware of the post exposure prophylaxis guideline. Conclusion The knowledge of the injection providers about safe injection practice was acceptable. The use of safe injection practice by providers in urban and rural health care facilities was almost similar. The deficiencies noted in the practice must be addressed. PMID:27540325

  18. Efficacy and safety of concurrent collagenase clostridium histolyticum injections for multiple Dupuytren contractures.

    PubMed

    Coleman, Stephen; Gilpin, David; Kaplan, F Thomas D; Houston, Anthony; Kaufman, Gregory J; Cohen, Brian M; Jones, Nigel; Tursi, James P

    2014-01-01

    To assess the safety and efficacy of 2 concurrent injections of collagenase clostridium histolyticum (CCH) in the same hand to treat multiple Dupuytren flexion contractures. In a multicenter, open-label phase IIIb study, 60 patients received two 0.58-mg CCH doses injected into cords affecting 2 joints in the same hand during 1 visit, followed by finger extension approximately 24 hours later. Efficacy at postinjection day 30 (change in flexion contracture and active range of motion, patient satisfaction, physician-rated improvement, and rates of clinical success [flexion contracture 5° or less]) and adverse events were summarized. The concurrent injections were most commonly administered in cords affecting metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints on the same finger (47%) or 2 MCP joints on different fingers of the same hand (37%). Mean total (sum of the 2 treated joints) flexion contracture decreased 76%, from 87° to 24° (MCP joints: 86%; PIP joints: 66%). Mean total range of motion increased from 100° to 161°. Clinical success was 76% for MCP joints and 33% for PIP joints. Most patients were very satisfied (60%) or quite satisfied (28%) with treatment. Most investigators rated treated joints as very much improved (55%) or much improved (37%). The most common treatment-related adverse events (> 75% of patients) were contusion, pain in extremity, and edema peripheral (local edema). Most adverse events were mild to moderate in severity. Serious complications included 1 pulley rupture related to study medication and 1 flexor tendon rupture (following conclusion of the study). There were no systemic complications. Results suggest that 2 affected joints can be effectively and safely treated with concurrent CCH injections. There was an increased incidence of some adverse events with concurrent treatment (pruritus, lymphadenopathy, blood blister, and skin laceration) compared with treatment of a single joint. High degrees of patient

  19. Safety of Repeated-Dose Intratympanic Injections with AM-101 in Acute Inner Ear Tinnitus.

    PubMed

    Staecker, Hinrich; Morelock, Michael; Kramer, Timothy; Chrbolka, Pavel; Ahn, Joong Ho; Meyer, Thomas

    2017-09-01

    Objective To evaluate the safety and tolerability of repeated intratympanic administration of the gel-formulated NMDA receptor antagonist AM-101 in acute patients with inner ear tinnitus. Study Design Prospective, double-blind, randomized, placebo-controlled study. Setting Sixty-nine secondary and tertiary sites in North America, Europe, and Asia. Subjects and Methods In total, 343 subjects with persistent acute tinnitus after traumatic cochlear injury or otitis media were randomized to receive 3 intratympanic doses of either AM-101 0.87 mg/mL or placebo over 3 to 5 days. They were followed for 84 days. The primary safety end point was the incidence of a clinically meaningful hearing deterioration from baseline to study day 35. Further safety assessments included tympanic membrane closure rates, analysis of adverse events, hematology, blood chemistry, and vital signs. In addition, data were collected on applied anesthetics and injection techniques. Results The treatment was well tolerated, with no intervention-related serious adverse events. The incidence of clinically meaningful hearing deterioration was low, comparable between treatment groups ( P = .82 for the primary safety end point) and not different between treated and untreated ears in unilaterally treated subjects. The rate of treatment and procedure-related adverse events was similar among treatment groups. The tympanic membrane was closed in 92% of subjects within 1 week and in all subjects by study day 84. Blood values and vital signs were inconspicuous. Conclusion Repeated intratympanic injections of AM-101 over a 3- to 5-day period appear to be safe and well tolerated, demonstrating the ability to potentially use this delivery approach over longer time periods.

  20. Safety and efficacy of bi-annual intra-articular LBSA0103 injections in patients with knee osteoarthritis.

    PubMed

    Lee, Jin Kyu; Choi, Chong-Hyuk; Oh, Kwang-Jun; Kyung, Hee-Soo; Yoo, Ju-Hyung; Ha, Chul-Won; Bin, Seong-Il; Kang, Seung-Baik; Kim, Myung Ku; Lee, Ju-Hong; Lee, Myung Chul

    2017-11-01

    The objective of this study is to assess the safety and efficacy of repeated intra-articular injection of high molecular weight hyaluronic acid (LBSA0103) at a 26-week interval, in patients with osteoarthritis of the knee. The study was an open-label, single arm, multicentre prospective trial conducted in patients with symptomatic knee osteoarthritis. The intervention consisted of two intra-articular injections of LBSA0103, with the second injection performed 26 weeks after the first injection. The primary outcome was the incidence of adverse drug reactions related to each injection. Assessment of efficacy of repeated injections in terms of maintenance of pain relief was a secondary objective of this study. Of the 185 patients screened, 174 patients received the first injection and 153 patients received both injections of LBSA0103. Nine adverse drug reactions occurred in seven patients (4.02%) after the first injection, while only one adverse drug reaction occurred (0.65%) after the second injection. As a secondary outcome measure, the improvements in the efficacy parameters including total WOMAC score and weight-bearing pain were all significant at both week 13 and 39 compared to the baseline value (P < 0.001), and improvements after the second injection were consistent with those after the initial injection of LBSA0103 (between week 26 and week 39, P < 0.001). Repeated intra-articular injection of LBSA0103 at a 26-week interval is safe without increased risk of adverse drug reactions. Additionally, LBSA0103 is effective in reduction of osteoarthritis knee pain and in maintenance of pain reduction for a 39-week period when a second injection is administered.

  1. Systemic safety project selection tool.

    DOT National Transportation Integrated Search

    2013-07-01

    "The Systemic Safety Project Selection Tool presents a process for incorporating systemic safety planning into traditional safety management processes. The Systemic Tool provides a step-by-step process for conducting systemic safety analysis; conside...

  2. FPGA-based multiprocessor system for injection molding control.

    PubMed

    Muñoz-Barron, Benigno; Morales-Velazquez, Luis; Romero-Troncoso, Rene J; Rodriguez-Donate, Carlos; Trejo-Hernandez, Miguel; Benitez-Rangel, Juan P; Osornio-Rios, Roque A

    2012-10-18

    The plastic industry is a very important manufacturing sector and injection molding is a widely used forming method in that industry. The contribution of this work is the development of a strategy to retrofit control of an injection molding machine based on an embedded system microprocessors sensor network on a field programmable gate array (FPGA) device. Six types of embedded processors are included in the system: a smart-sensor processor, a micro fuzzy logic controller, a programmable logic controller, a system manager, an IO processor and a communication processor. Temperature, pressure and position are controlled by the proposed system and experimentation results show its feasibility and robustness. As validation of the present work, a particular sample was successfully injected.

  3. The effectiveness of a mail reminder system for depot medroxyprogesterone injections.

    PubMed

    Madlon-Kay, D J

    1996-04-01

    To determine if a mail reminder system leads to an increase in the percentage of depot medroxyprogesterone acetate (Depo-Provera) injections administered on time, the charts of 184 women were reviewed. The reminder postcard included the due dates of both the next medroxyprogesterone injection and the next Papanicolaou test. Timeliness of injections improved with the reminder system from 64% administered on time to 76% (P < .02). Injections given late despite the reminders were late a mean of 8 days. Injections given late before the reminder system began were late a mean of 20 days (P < .05). If injections given during the injection's 14-day "grace" period are included, the on-time rate improved from 87% to 96% with the reminder system (P < .005). The reminder system was not effective in ensuring annual Papanicolaou testing. Vigilance is needed to ensure that women receiving medroxyprogesterone injections also receive timely Papanicolaou testing.

  4. Quality Control of Injection Molded Eyewear by Non-Contact Deflectometry

    NASA Astrophysics Data System (ADS)

    Speck, A.; Zelzer, B.; Langenbucher, A.; Eppig, T.

    2014-07-01

    Occupational eye wear such as safety spectacles are manufactured by injection molding techniques. Testing of the assembled safety spectacle lenses in transmission is state of the art, but there is a lack of surface measurement systems for occupational safety lenses. The purpose of this work was to validate a deflectometric setup for topography measurement, detection of defects and visualization of the polishing quality, e.g. casting indentations or impressions, for the production process of safety spectacles. The setup is based on a customized stereo phase measuring deflectometer (PMD), equipped with 3 cameras with f'1,2 = 16 mm and f'3 = 8.5 mm and a specified measurement uncertainty of ± 3 μm. Sixteen plastic lenses and 8 corresponding injection molds from 4 parallel cavities were used for validation of the deflectometer. For comparison an interferometric method and a reference standard (< λ/10 super polished) was used. The accuracy and bias with a spherical safety spectacle sample was below 1 μm, according to DIN ISO 5725-2.2002-12. The repeatability was 2.1 μm and 35.7 μm for a blind radius fit. In conclusion, the PMD technique is an appropriate tool for characterizing occupational safety spectacle and injections mold surfaces. With the presented setup we were able to quantify the surface quality. This can be useful and may optimize the quality of the end product, in addition to standardized measuring systems in transmission.

  5. Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial.

    PubMed

    Alam, Murad; Levy, Ross; Pajvani, Urvi; Pavjani, Urvi; Ramierez, James A; Guitart, Joan; Veen, Heather; Gladstone, Hayes B

    2006-03-01

    Several soft-tissue augmentation materials are now available for reduction of nasolabial fold creases and perioral rhytides. Nasolabial folds and perioral rhytides can also be improved by skin tightening delivered by non-ablative radiofrequency (RF) treatment. The purpose of this study was to assess the safety of RF treatment over skin areas recently injected with medium-term injectable soft-tissue augmentation materials. Five subjects were assigned to the experimental arm (augmentation materials plus RF) and one to the control arm (augmentation materials alone). Each subject received injections of 0.3 mL of hyaluronic acid derivative (Restylane) and calcium hydroxylapatite (Radiesse) 3 cm apart on the upper inner arm. Two weeks later, two non-overlapping passes of RF (Thermage ThermaCool TC) were delivered at 63.5 setting with medium-fast 1.5 cm2 tip over injected sites in all of the experimental subjects. Punch skin biopsies were obtained 3 days later from each of the two injection sites on each subject. Light microscopy and digital photomicrographs obtained at low, medium, and high power showed no difference between filler materials in experimental and control subjects. In both cases filler was evident at the deep dermal-subcutaneous junction. Nodule formation, foreign body extravasation, or hemorrhage/clot was not observed grossly or histologically. Subjects and physicians did not report any difference in signs and symptoms between the experimental and control arms. Slightly increased transitory pain was noted when RF was delivered over filler versus over normal skin. Applying RF treatment over the same area 2 weeks after deep dermal injection with hyaluronic acid derivatives or calcium hydroxylapatite does not appear to cause gross morphological changes in the filler material or surrounding skin. Further studies with different parameters are necessary to confirm these findings. 2006 Wiley-Liss, Inc.

  6. Multiple intravenous injections of allogeneic equine mesenchymal stem cells do not induce a systemic inflammatory response but do alter lymphocyte subsets in healthy horses.

    PubMed

    Kol, Amir; Wood, Joshua A; Carrade Holt, Danielle D; Gillette, Jessica A; Bohannon-Worsley, Laurie K; Puchalski, Sarah M; Walker, Naomi J; Clark, Kaitlin C; Watson, Johanna L; Borjesson, Dori L

    2015-04-15

    Intravenous (IV) injection of mesenchymal stem cells (MSCs) is used to treat systemic human diseases and disorders but is not routinely used in equine therapy. In horses, MSCs are isolated primarily from adipose tissue (AT) or bone marrow (BM) and used for treatment of orthopedic injuries through one or more local injections. The objective of this study was to determine the safety and lymphocyte response to multiple allogeneic IV injections of either AT-derived MSCs (AT-MSCs) or BM-derived MSCs (BM-MSCs) to healthy horses. We injected three doses of 25 × 10(6) allogeneic MSCs from either AT or BM (a total of 75 × 10(6) MSCs per horse) into five and five, respectively, healthy horses. Horses were followed up for 35 days after the first MSC infusion. We evaluated host inflammatory and immune response, including total leukocyte numbers, serum cytokine concentration, and splenic lymphocyte subsets. Repeated injection of allogeneic AT-MSCs or BM-MSCs did not elicit any clinical adverse effects. Repeated BM-MSC injection resulted in increased blood CD8(+) T-cell numbers. Multiple BM-MSC injections also increased splenic regulatory T cell numbers compared with AT-MSC-injected horses but not controls. These data demonstrate that multiple IV injections of allogeneic MSCs are well tolerated by healthy horses. No clinical signs or clinico-pathologic measurements of organ toxicity or systemic inflammatory response were recorded. Increased numbers of circulating CD8(+) T cells after multiple IV injections of allogeneic BM-MSCs may indicate a mild allo-antigen-directed cytotoxic response. Safety and efficacy of allogeneic MSC IV infusions in sick horses remain to be determined.

  7. Microcontroller-driven fluid-injection system for atomic force microscopy.

    PubMed

    Kasas, S; Alonso, L; Jacquet, P; Adamcik, J; Haeberli, C; Dietler, G

    2010-01-01

    We present a programmable microcontroller-driven injection system for the exchange of imaging medium during atomic force microscopy. Using this low-noise system, high-resolution imaging can be performed during this process of injection without disturbance. This latter circumstance was exemplified by the online imaging of conformational changes in DNA molecules during the injection of anticancer drug into the fluid chamber.

  8. A global health partnership's use of time-limited support to catalyze health practice change: the case of GAVI's Injection Safety Support.

    PubMed

    Levin, Ann; Fang, Arnold; Hansen, Peter M; Pyle, David; Dia, Ousmane; Schwalbe, Nina

    2010-09-27

    This paper presents the findings of a study to assess the effectiveness and sustainability of a GAVI (Global Alliance of Vaccines and Immunization) sponsored, time-limited Injection Safety (INS) support. The support came in two forms: 1) in-kind, in the form of AD syringes and safety boxes, and 2) in cash, for those countries that already had a secure, multi-year source of AD syringes and safety boxes, but proposed to use INS support to strengthen their injection safety activities. In total, GAVI gave INS support for a three-year period to 58 countries: 46 with commodities and 12 with cash support. To identify variables that might be associated with financial sustainability, frequencies and cross-tabulations were run against various programmatic and socio-economic variables in the 58 countries. All but two of the 46 commodity-recipient countries were able to replace and sustain the use of AD syringes and safety boxes after the end of their GAVI INS support despite the fact that standard disposable syringes are less costly than ADs (10-15 percent differential). In addition, all 12 cash-recipient countries continued to use AD syringes and safety boxes in their immunization programs in the years following GAVI INS assistance. At the same time, countries were often not prepared for the increased waste management requirements associated with the use of the syringes, suggesting the importance of anticipating challenges with the introduction of new technologies. The sustained use of AD syringes in countries receiving injection safety support from GAVI, in a majority of cases through government financing, following the completion of three years of time-limited support, represents an early indication of how GHPs can contribute to improved health outcomes in immunization safety in the world's poorest countries in a sustainable way.

  9. FPGA-Based Multiprocessor System for Injection Molding Control

    PubMed Central

    Muñoz-Barron, Benigno; Morales-Velazquez, Luis; Romero-Troncoso, Rene J.; Rodriguez-Donate, Carlos; Trejo-Hernandez, Miguel; Benitez-Rangel, Juan P.; Osornio-Rios, Roque A.

    2012-01-01

    The plastic industry is a very important manufacturing sector and injection molding is a widely used forming method in that industry. The contribution of this work is the development of a strategy to retrofit control of an injection molding machine based on an embedded system microprocessors sensor network on a field programmable gate array (FPGA) device. Six types of embedded processors are included in the system: a smart-sensor processor, a micro fuzzy logic controller, a programmable logic controller, a system manager, an IO processor and a communication processor. Temperature, pressure and position are controlled by the proposed system and experimentation results show its feasibility and robustness. As validation of the present work, a particular sample was successfully injected. PMID:23202036

  10. Closed-Loop Control of Chemical Injection Rate for a Direct Nozzle Injection System.

    PubMed

    Cai, Xiang; Walgenbach, Martin; Doerpmond, Malte; Schulze Lammers, Peter; Sun, Yurui

    2016-01-20

    To realize site-specific and variable-rate application of agricultural pesticides, accurately metering and controlling the chemical injection rate is necessary. This study presents a prototype of a direct nozzle injection system (DNIS) by which chemical concentration transport lag was greatly reduced. In this system, a rapid-reacting solenoid valve (RRV) was utilized for injecting chemicals, driven by a pulse-width modulation (PWM) signal at 100 Hz, so with varying pulse width the chemical injection rate could be adjusted. Meanwhile, a closed-loop control strategy, proportional-integral-derivative (PID) method, was applied for metering and stabilizing the chemical injection rate. In order to measure chemical flow rates and input them into the controller as a feedback in real-time, a thermodynamic flowmeter that was independent of chemical viscosity was used. Laboratory tests were conducted to assess the performance of DNIS and PID control strategy. Due to the nonlinear input-output characteristics of the RRV, a two-phase PID control process obtained better effects as compared with single PID control strategy. Test results also indicated that the set-point chemical flow rate could be achieved within less than 4 s, and the output stability was improved compared to the case without control strategy.

  11. Closed-Loop Control of Chemical Injection Rate for a Direct Nozzle Injection System

    PubMed Central

    Cai, Xiang; Walgenbach, Martin; Doerpmond, Malte; Schulze Lammers, Peter; Sun, Yurui

    2016-01-01

    To realize site-specific and variable-rate application of agricultural pesticides, accurately metering and controlling the chemical injection rate is necessary. This study presents a prototype of a direct nozzle injection system (DNIS) by which chemical concentration transport lag was greatly reduced. In this system, a rapid-reacting solenoid valve (RRV) was utilized for injecting chemicals, driven by a pulse-width modulation (PWM) signal at 100 Hz, so with varying pulse width the chemical injection rate could be adjusted. Meanwhile, a closed-loop control strategy, proportional-integral-derivative (PID) method, was applied for metering and stabilizing the chemical injection rate. In order to measure chemical flow rates and input them into the controller as a feedback in real-time, a thermodynamic flowmeter that was independent of chemical viscosity was used. Laboratory tests were conducted to assess the performance of DNIS and PID control strategy. Due to the nonlinear input–output characteristics of the RRV, a two-phase PID control process obtained better effects as compared with single PID control strategy. Test results also indicated that the set-point chemical flow rate could be achieved within less than 4 s, and the output stability was improved compared to the case without control strategy. PMID:26805833

  12. INJECTION SYSTEM DESIGN FOR THE BSNS/RCS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WEI, J.; TANG, J.Y.; CHEN, Y.

    2006-06-23

    The BSNS injection system is designed to take one uninterrupted long drift in one of the four dispersion-free straight sections to host all the injection devices. Painting bumper magnets are used for both horizontal and vertical phase space painting. Closed-orbit bumper magnets are used for facilitating the installation of the injection septa and decreasing proton traversal in the stripping foil. Even with large beam emittance of about 300 {pi}mm.mrad used, BSNS/RCS still approaches the space charge limit during the injection/trapping phase for the accumulated particles of 1.9*10{sup 13} and at the low injection energy of 80 MeV. Uniform-like beam distributionmore » by well-designed painting scheme is then obtained to decrease the tune shift/spread. ORBIT code is used for the 3D simulations. Upgrading to higher injection energy has also been considered.« less

  13. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  14. Discharge characteristics of a high speed fuel injection system

    NASA Technical Reports Server (NTRS)

    Matthews, Robertson

    1925-01-01

    Discussed here are some discharge characteristics of a fuel injection system intended primarily for high speed service. The system consisted of a cam actuated fuel pump, a spring loaded automatic injection valve, and a connecting tube.

  15. Efficacy and safety of flurbiprofen axetil in the prevention of pain on propofol injection: a systematic review and meta-analysis.

    PubMed

    Zhang, Lieliang; Zhu, Juan; Xu, Lei; Zhang, Xunlei; Wang, Hongyu; Luo, Zhonghua; Zhao, Yamei; Yu, Yi; Zhang, Yong; Shi, Hongwei; Bao, Hongguang

    2014-06-17

    Pain on injection is an acknowledged adverse effect (AE) of propofol administration for the induction of general anesthesia. Flurbiprofen axetil has been reported to reduce the pain of injection. However, results of published papers on the efficacy of flurbiprofen axetil in managing pain on injection of propofol are inconsistent. We conducted a comprehensive meta-analysis of studies to appraise the efficacy and safety of flurbiprofen axetil for controlling pain induced by propofol injection. The pooled risk ratio (RR) with corresponding 95% confidence intervals (CI) was calculated employing fixed- or random-effects models, depending upon the heterogeneity of the included trials. Compared with the placebo group, flurbiprofen axetil allows more patients to have no pain (RR 3.51, 95% CI 2.22-5.55, p=0.000), and decreases the cumulative number of patients with mild, moderate, and severe pain on injecting propofol (RR 0.70, 95% CI 0.58-0.86, p=0.000; RR 0.59, 95% CI 0.46-0.75, p=0.000; RR 0.25, 95% CI 0.16-0.38, p=0.000, respectively). In the stratified analysis by the doses, flurbiprofen axetil at a dose of over 50 mg was found to be effective in reducing propofol-induced pain on injection; however, there were no significant differences in relieving pain between treatment and placebo groups with flurbiprofen axetil at a dose of 25 mg. In terms of drug safety, there were no adverse effects (AEs) reported between flurbiprofen axetil-based regimens and placebo regimens. Flurbiprofen axetil, an injectable prodrug of flurbiprofen, can significantly prevent or relieve the pain induced by propofol injection. More studies are required to assess its adverse effects.

  16. Design and Testing of Trace Contaminant Injection and Monitoring Systems

    NASA Technical Reports Server (NTRS)

    Broerman, Craig D.; Sweterlitsch, Jeff

    2009-01-01

    In support of the Carbon dioxide And Moisture Removal Amine Swing-bed (CAMRAS) testing, a contaminant injection system as well as a contaminant monitoring system has been developed by the Johnson Space Center Air Revitalization Systems (JSC-ARS) team. The contaminant injection system has been designed to provide trace level concentrations of contaminants generated by humans in a closed environment during space flight missions. The contaminant injection system continuously injects contaminants from three gas cylinders, two liquid reservoirs and three permeation ovens. The contaminant monitoring system has been designed to provide real time gas analysis with accurate flow, humidity and gas concentration measurements for collection during test. The contaminant monitoring system consists of an analytical real time gas analyzer, a carbon monoxide sensor, and an analyzer for ammonia and water vapor.

  17. Influence of pre-injection control parameters on main-injection fuel quantity for an electronically controlled double-valve fuel injection system of diesel engine

    NASA Astrophysics Data System (ADS)

    Song, Enzhe; Fan, Liyun; Chen, Chao; Dong, Quan; Ma, Xiuzhen; Bai, Yun

    2013-09-01

    A simulation model of an electronically controlled two solenoid valve fuel injection system for a diesel engine is established in the AMESim environment. The accuracy of the model is validated through comparison with experimental data. The influence of pre-injection control parameters on main-injection quantity under different control modes is analyzed. In the spill control valve mode, main-injection fuel quantity decreases gradually and then reaches a stable level because of the increase in multi-injection dwell time. In the needle control valve mode, main-injection fuel quantity increases with rising multi-injection dwell time; this effect becomes more obvious at high-speed revolutions and large main-injection pulse widths. Pre-injection pulse width has no obvious influence on main-injection quantity under the two control modes; the variation in main-injection quantity is in the range of 1 mm3.

  18. A prototype space flight intravenous injection system

    NASA Technical Reports Server (NTRS)

    Colombo, G. V.

    1985-01-01

    Medical emergencies, especially those resulting from accidents, frequently require the administration of intravenous fluids to replace lost body liquids. The development of a prototype space flight intravenous injection system is presented. The definition of requirements, injectable concentrates development, water polisher, reconstitution hardware development, administration hardware development, and prototype fabrication and testing are discussed.

  19. Autonomous Flight Safety System

    NASA Technical Reports Server (NTRS)

    Ferrell, Bob; Santuro, Steve; Simpson, James; Zoerner, Roger; Bull, Barton; Lanzi, Jim

    2004-01-01

    Autonomous Flight Safety System (AFSS) is an independent flight safety system designed for small to medium sized expendable launch vehicles launching from or needing range safety protection while overlying relatively remote locations. AFSS replaces the need for a man-in-the-loop to make decisions for flight termination. AFSS could also serve as the prototype for an autonomous manned flight crew escape advisory system. AFSS utilizes onboard sensors and processors to emulate the human decision-making process using rule-based software logic and can dramatically reduce safety response time during critical launch phases. The Range Safety flight path nominal trajectory, its deviation allowances, limit zones and other flight safety rules are stored in the onboard computers. Position, velocity and attitude data obtained from onboard global positioning system (GPS) and inertial navigation system (INS) sensors are compared with these rules to determine the appropriate action to ensure that people and property are not jeopardized. The final system will be fully redundant and independent with multiple processors, sensors, and dead man switches to prevent inadvertent flight termination. AFSS is currently in Phase III which includes updated algorithms, integrated GPS/INS sensors, large scale simulation testing and initial aircraft flight testing.

  20. Efficacy and safety of cross-linked hyaluronic acid single injection on osteoarthritis of the knee: a post-marketing Phase IV study.

    PubMed

    Bashaireh, Khaldoon; Naser, Ziad; Hawadya, Khaled Al; Sorour, Sorour; Al-Khateeb, Rami Nabeel

    2015-01-01

    The primary objective of this study was to evaluate the efficacy, safety, and duration of action of viscosupplementation with Crespine® Gel over a 9-month period. The study was a post-marketing Phase IV study. A total of 109 participants with osteoarthritis of the knee (grades 1-4) in the tibio-femoral compartment were recruited in Jordan. Data were collected from each participant during the baseline visit. Each participant received Crespine® Gel injection, and follow-up visits took place at 3 months, 6 months, and 9 months post-injection. An assessment of participants by phone was conducted at 1 month, 2 months, 4 months, 5 months, 7 months, and 8 months post-injection. Western Ontario and McMaster Universities Arthritis Index questionnaires were completed during each visit. A 72-hour visit questionnaire was used to assess the safety of the injection. Statistical analysis included a two-sided 95% confidence interval for the difference between pain scores across visits, and the percent change from baseline was calculated. The full analysis included 84 participants who gave their informed consent and finished the necessary baseline and follow-up visits needed to assess efficacy and safety. Peak improvement was noted at 5 months post-injection, when pain and physical performance scores had decreased to 2.60 and 9.90, respectively, and the stiffness score was 0.33. The peak improvement in stiffness was noted at 8 months post-injection, when the stiffness score had decreased to 0.32. Significant improvements were still apparent at 9 months post-injection, when the pain score was 3.36, the stiffness score was 0.42, and the physical performance score was 11.5. All side effects were local and transient, and included pain, swelling, and redness of the knee. Most side effects were treated. Hyaluronan should be encouraged as an alternative or adjunct treatment to oral analgesics to reduce their required doses, and delay potential future surgical intervention.

  1. Efficacy and safety of cross-linked hyaluronic acid single injection on osteoarthritis of the knee: a post-marketing Phase IV study

    PubMed Central

    Bashaireh, Khaldoon; Naser, Ziad; Hawadya, Khaled Al; Sorour, Sorour; Al-Khateeb, Rami Nabeel

    2015-01-01

    Purpose The primary objective of this study was to evaluate the efficacy, safety, and duration of action of viscosupplementation with Crespine® Gel over a 9-month period. Materials and methods The study was a post-marketing Phase IV study. A total of 109 participants with osteoarthritis of the knee (grades 1–4) in the tibio–femoral compartment were recruited in Jordan. Data were collected from each participant during the baseline visit. Each participant received Crespine® Gel injection, and follow-up visits took place at 3 months, 6 months, and 9 months post-injection. Main outcome measure(s) An assessment of participants by phone was conducted at 1 month, 2 months, 4 months, 5 months, 7 months, and 8 months post-injection. Western Ontario and McMaster Universities Arthritis Index questionnaires were completed during each visit. A 72-hour visit questionnaire was used to assess the safety of the injection. Statistical analysis included a two-sided 95% confidence interval for the difference between pain scores across visits, and the percent change from baseline was calculated. Main results The full analysis included 84 participants who gave their informed consent and finished the necessary baseline and follow-up visits needed to assess efficacy and safety. Peak improvement was noted at 5 months post-injection, when pain and physical performance scores had decreased to 2.60 and 9.90, respectively, and the stiffness score was 0.33. The peak improvement in stiffness was noted at 8 months post-injection, when the stiffness score had decreased to 0.32. Significant improvements were still apparent at 9 months post-injection, when the pain score was 3.36, the stiffness score was 0.42, and the physical performance score was 11.5. All side effects were local and transient, and included pain, swelling, and redness of the knee. Most side effects were treated. Conclusion Hyaluronan should be encouraged as an alternative or adjunct treatment to oral analgesics to reduce

  2. Engine performance with a hydrogenated safety fuel

    NASA Technical Reports Server (NTRS)

    Schey, Oscar W; Young, Alfred W

    1933-01-01

    This report presents the results of an investigation to determine the engine performance obtained with a hydrogenated safety fuel developed to eliminate fire hazard. The tests were made on a single-cylinder universal test engine at compression ratios of 5.0, 5.5, and 6.0. Most of the tests were made with a fuel-injection system, although one set of runs was made with a carburetor when using gasoline to establish comparative performance. The tests show that the b.m.e.p. obtained with safety fuel when using a fuel-injection system is slightly higher than that obtained with gasoline when using a carburetor, although the fuel consumption with safety fuel is higher. When the fuel-injection system is used with each fuel and with normal engine temperatures the b.m.e.p. with safety fuel is from 2 to 4 percent lower than with gasoline and the fuel consumption about 25 to 30 percent higher. However, a few tests at an engine coolant temperature of 250 F have shown a specific fuel consumption approximating that obtained with gasoline with only a slight reduction in power. The idling of the test engine was satisfactory with the safety fuel. Starting was difficult with a cold engine but could be readily accomplished when the jacket water was hot. It is believed that the use of the safety fuel would practically eliminate crash fires.

  3. Fast Time Response Electromagnetic Particle Injection System for Disruption Mitigation

    NASA Astrophysics Data System (ADS)

    Raman, Roger; Lay, W.-S.; Jarboe, T. R.; Menard, J. E.; Ono, M.

    2017-10-01

    Predicting and controlling disruptions is an urgent issue for ITER. In this proposed method, a radiative payload consisting of micro spheres of Be, BN, B, or other acceptable low-Z materials would be injected inside the q =2 surface for thermal and runaway electron mitigation. The radiative payload would be accelerated to the required velocities (0.2 to >1km/s) in an Electromagnetic Particle Injector (EPI). An important advantage of the EPI system is that it could be positioned very close to the reactor vessel. This has the added benefit that the external field near a high-field tokamak dramatically improves the injector performance, while simultaneously reducing the system response time. A NSTX-U / DIII-D scale system has been tested off-line to verify the critical parameters - the projected system response time and attainable velocities. Both are consistent with the model calculations, giving confidence that an ITER-scale system could be built to ensure safety of the ITER device. This work is supported by U.S. DOE Contracts: DE-AC02-09CH11466, DE-FG02-99ER54519 AM08, and DE-SC0006757.

  4. Safety Study: Intraventricular Injection of a Modified Oncolytic Measles Virus into Measles-Immune, hCD46-Transgenic, IFNαRko Mice.

    PubMed

    Lal, Sangeet; Peng, Kah-Whye; Steele, Michael B; Jenks, Nathan; Ma, Hong; Kohanbash, Gary; Phillips, Joanna J; Raffel, Corey

    2016-12-01

    The modified Edmonston vaccine strain of measles virus (MV) has shown potent oncolytic efficacy against various tumor types and is being investigated in clinical trials. Our laboratory showed that MV effectively kills medulloblastoma tumor cells in both localized disease and when tumor cells are disseminated through cerebrospinal fluid (CSF). Although the safety of repeated intracerebral injection of modified MV in rhesus macaques has been established, the safety of administering MV into CSF has not been adequately investigated. In this study, we assessed the safety of MV-NIS (MV modified to express the human sodium iodide symporter protein) injected into the CSF of measles-immunized and measles virus-susceptible transgenic (CD46, IFNαRko) mice. Treated animals were administered a single intraventricular injection of 1 × 10 5 or 1 × 10 6 TCID 50 (50% tissue culture infective dose) of MV-NIS. Detailed clinical observation was performed over a 90-day period. Clinically, we did not observe any measles-related toxic effects or behavioral abnormality in animals of any treated cohort. The complete blood count and blood chemistry analysis results were found to be within normal range for all the cohorts. Histologic examination of brains and spinal cords revealed inflammatory changes, mostly related to the needle track; these resolved by day 21 postinjection. To assess viral biodistribution, quantitative RT-PCR to detect the measles virus N-protein was performed on blood and brain samples. Viral RNA was not detectable in the blood as soon as 2 days after injection, and virus cleared from the brain by 45 days postadministration in all treatment cohorts. In conclusion, our data suggest that a single injection of modified MV into the CSF is safe and can be used in future therapeutic applications.

  5. Designing Fault-Injection Experiments for the Reliability of Embedded Systems

    NASA Technical Reports Server (NTRS)

    White, Allan L.

    2012-01-01

    This paper considers the long-standing problem of conducting fault-injections experiments to establish the ultra-reliability of embedded systems. There have been extensive efforts in fault injection, and this paper offers a partial summary of the efforts, but these previous efforts have focused on realism and efficiency. Fault injections have been used to examine diagnostics and to test algorithms, but the literature does not contain any framework that says how to conduct fault-injection experiments to establish ultra-reliability. A solution to this problem integrates field-data, arguments-from-design, and fault-injection into a seamless whole. The solution in this paper is to derive a model reduction theorem for a class of semi-Markov models suitable for describing ultra-reliable embedded systems. The derivation shows that a tight upper bound on the probability of system failure can be obtained using only the means of system-recovery times, thus reducing the experimental effort to estimating a reasonable number of easily-observed parameters. The paper includes an example of a system subject to both permanent and transient faults. There is a discussion of integrating fault-injection with field-data and arguments-from-design.

  6. Efficacy and safety of closing postcatheterisation pseudoaneurysms with ultrasound-guided thrombin injections using two approaches: bolus versus slow injection. A prospective randomised trial.

    PubMed

    Lewandowski, Paweł; Maciejewski, Paweł; Wąsek, Wojciech; Pasierski, Tomasz; Budaj, Andrzej

    2011-01-01

    Thrombin injection is a widely accepted treatment of an iatrogenic arterial pseudoaneurysm. However, the optimal mode of injection and type of pseudoaneurysm amenable to this therapy have yet been established. To compare efficacy and safety of two approaches to ultrasound-guided thrombin injections into a femoral artery pseudoaneurysm with or without long neck that developed as an iatrogenic complication of cardiac catheterisation. Patients were randomised to thrombin administration in a bolus or slow injection. The length and width of aneurysm neck and blood flow velocity in the neck were measured with color Doppler ultrasonography before the closure procedure. Thrombin dose, time to thrombotic occlusion, blood oxygen saturation in a toe of the extremity with the pseudoaneurysm (a marker of silent microembolisation), and clinical signs of distal embolisation were recorded. Between 2006 and 2009, 73 consecutive patients (33 males; mean age 67.8 ± 11.9 years) with femoral pseudoaneurysms complicating cardiac catheterisation were randomised into two groups that were treated with thrombin bolus (n = 40) or slow injection (n = 33). The efficacy of aneurysm closure with either method was similarly high (100% vs 96.8%, NS, respectively) and did not depend on the length and width of the aneurysm neck. Independent risk factors for distal embolisation were: thrombin dose (OR 4.2; 95% CI 0.92-19.3), the length of aneurysm neck (OR 4.66; 95% CI 1.1-19.9), age above 80 years (OR 10.9; 95% CI 1.0-116.8), and bolus treatment (OR 7.6; 95% CI 1.3-44.9). We observed silent microembolisation phenomenon that was common (occurring in 38% of patients in the bolus group vs 33% of patients in the slow injection group) but in most cases asymptomatic. Femoral pseudoaneurysm closure with a low dose of thrombin is a valid and beneficial treatment. Either method (bolus or slow injection) was similarly efficacious and safe even in the subgroup of patients with neckless aneurysms. We observed

  7. Efficacy and safety of repeated courses of hyaluronic acid injections for knee osteoarthritis: A systematic review.

    PubMed

    Altman, Roy; Hackel, Josh; Niazi, Faizan; Shaw, Peter; Nicholls, Mathew

    2018-01-31

    Hyaluronic acid (HA) is a commonly prescribed intra-articular (IA) therapy for knee osteoarthritis (OA). While a single series of IA-HA has been well studied, the efficacy and safety of repeated courses of IA-HA injection therapy in knee OA patients have not been evaluated as frequently. A literature search was conducted using MEDLINE, EMBASE and PubMed databases. The primary outcome measure was knee pain reduction after each treatment course and/or last reported follow-up visit. Secondary outcomes were treatment-related adverse events (AEs) and serious adverse events (SAEs). A total of 17 articles (7 RCTs and 10 cohort studies) met the pre-defined inclusion criteria. Of the RCTs, six were double-blind with two trials including open label extension studies, and one was single-blind. Studies ranged from investigating a single reinjection cycle to four repeat injection cycles. Eleven studies evaluated one reinjection, five studies evaluated ≥2 repeated courses of IA-HA, and one study allowed either one or two repeated courses. All studies reported pain reduction from baseline in the IA-HA treatment group throughout the initial treatment cycle, and either sustained or further reduced pain throughout the repeated courses of treatment. The study with the longest follow-up repeated IA-HA injection every 6 months for 25 months. Pain decreased after the first course and continued to decrease until the end of the study, with an approximate 55% reduction in pain compared to baseline. Common AEs were joint swelling and arthralgia; there were no reported SAEs. All repeated courses were well tolerated, and the number of documented AEs and SAEs was similar to the primary injection regimens. Repeated courses of IA-HA injections are an effective and safe treatment for knee OA. Repeat courses were demonstrated to maintain or further improve pain reduction while introducing no increased safety risk. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Efficacy and safety of single injection of cross-linked sodium hyaluronate vs. three injections of high molecular weight sodium hyaluronate for osteoarthritis of the knee: a double-blind, randomized, multi-center, non-inferiority study.

    PubMed

    Ha, Chul-Won; Park, Yong-Beom; Choi, Chong-Hyuk; Kyung, Hee-Soo; Lee, Ju-Hong; Yoo, Jae Doo; Yoo, Ju-Hyung; Choi, Choong-Hyeok; Kim, Chang-Wan; Kim, Hee-Chun; Oh, Kwang-Jun; Bin, Seong-Il; Lee, Myung Chul

    2017-05-26

    This randomized, double-blind, multi-center, non-inferiority trial was conducted to assess the efficacy and safety of a cross-linked hyaluronate (XLHA, single injection form) compared with a linear high molecular hyaluronate (HMWHA, thrice injection form) in patients with symptomatic knee osteoarthritis. Two hundred eighty seven patients with osteoarthritis (Kellgren-Lawrence grade I to III) were randomized to each group. Three weekly injections were given in both groups but two times of saline injections preceded XLHA injection to maintain double-blindness. Primary endpoint was the change of weight-bearing pain (WBP) at 12 weeks after the last injection. Secondary endpoints included Western Ontario and McMaster Universities Osteoarthritis index; patient's and investigator's global assessment; pain at rest, at night, or in motion; OMERACT-OARSI responder rate; proportion of patients achieving at least 20 mm or 40% decrease in WBP; and rate of rescue medicine use and its total consumption. Mean changes of WBP at 12 weeks after the last injection were -33.3 mm with XLHA and -29.2 mm with HMWHA, proving non-inferiority of XLHA to HMWHA as the lower bound of 95% CI (-1.9 mm, 10.1 mm) was well above the predefined margin (-10 mm). There were no significant between-group differences in all secondary endpoints. Injection site pain was the most common adverse event and no remarkable safety issue was identified. This study demonstrated that a single injection of XLHA was non-inferior to three weekly injections of HMWHA in terms of WBP reduction, and supports XLHA as an effective and safe treatment for knee osteoarthritis. ClinicalTrials.gov ( NCT01510535 ). This trial was registered on January 6, 2012.

  9. Variable volume combustor with pre-nozzle fuel injection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keener, Christopher Paul; Johnson, Thomas Edward; McConnaughhay, Johnie Franklin

    The present application provides a combustor for use with a gas turbine engine. The combustor may include a number of fuel nozzles, a pre-nozzle fuel injection system supporting the fuel nozzles, and a linear actuator to maneuver the fuel nozzles and the pre-nozzle fuel injection system.

  10. Pressure Fluctuations in a Common-Rail Fuel Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M

    1931-01-01

    This report presents the results of an investigation to determine experimentally the instantaneous pressures at the discharge orifice of a common-rail fuel injection system in which the timing valve and cut-off valve were at some distance from the automatic fuel injection valve, and also to determine the methods by which the pressure fluctuations could be controlled. The results show that pressure wave phenomena occur between the high-pressure reservoir and the discharge orifice, but that these pressure waves can be controlled so as to be advantageous to the injection of the fuel. The results also give data applicable to the design of such an injection system for a high-speed compression-ignition engine.

  11. Transition duct with late injection in turbine system

    DOEpatents

    LeBegue, Jeffrey Scott; Pentecost, Ronnie Ray; Flanagan, James Scott; Kim, Won -Wook; McMahan, Kevin Weston

    2015-09-15

    A system for supplying an injection fluid to a combustor is disclosed. The system includes a transition duct comprising an inlet, an outlet, and a passage extending between the inlet and the outlet and defining a longitudinal axis, a radial axis, and a tangential axis. The outlet of the transition duct is offset from the inlet along the longitudinal axis and the tangential axis. The passage defines a combustion chamber. The system further includes a tube providing fluid communication for the injection fluid to flow through the transition duct and into the combustion chamber.

  12. The procedure safety system

    NASA Technical Reports Server (NTRS)

    Obrien, Maureen E.

    1990-01-01

    Telerobotic operations, whether under autonomous or teleoperated control, require a much more sophisticated safety system than that needed for most industrial applications. Industrial robots generally perform very repetitive tasks in a controlled, static environment. The safety system in that case can be as simple as shutting down the robot if a human enters the work area, or even simply building a cage around the work space. Telerobotic operations, however, will take place in a dynamic, sometimes unpredictable environment, and will involve complicated and perhaps unrehearsed manipulations. This creates a much greater potential for damage to the robot or objects in its vicinity. The Procedural Safety System (PSS) collects data from external sensors and the robot, then processes it through an expert system shell to determine whether an unsafe condition or potential unsafe condition exists. Unsafe conditions could include exceeding velocity, acceleration, torque, or joint limits, imminent collision, exceeding temperature limits, and robot or sensor component failure. If a threat to safety exists, the operator is warned. If the threat is serious enough, the robot is halted. The PSS, therefore, uses expert system technology to enhance safety thus reducing operator work load, allowing him/her to focus on performing the task at hand without the distraction of worrying about violating safety criteria.

  13. Post-licensure safety surveillance of 23-valent pneumococcal polysaccharide vaccine in the Vaccine Adverse Event Reporting System (VAERS), 1990-2013.

    PubMed

    Miller, Elaine R; Moro, Pedro L; Cano, Maria; Lewis, Paige; Bryant-Genevier, Marthe; Shimabukuro, Tom T

    2016-05-27

    23-Valent pneumococcal polysaccharide vaccine, trade name Pneumovax(®)23 (PPSV23), has been used for decades in the Unites States and has an extensive clinical record. However, limited post-licensure safety assessment has been conducted. To analyze reports submitted to the Vaccine Adverse Event Reporting System (VAERS) following PPSV23 from 1990 to 2013 in order to characterize its safety profile. We searched the VAERS database for US reports following PPSV23 for persons vaccinated from 1990 to 2013. We assessed safety through: automated analysis of VAERS data, crude adverse event (AE) reporting rates based on PPSV23 doses distributed in the US market, clinical review of death reports and reports involving vaccine administered to pregnant women, and empirical Bayesian data mining to assess for disproportional reporting. During the study period, VAERS received 25,168 PPSV23 reports; 92% were non-serious, 67% were in females and 86% were in adults aged ≥19 years. When PPSV23 was administered alone, fever (43%), injection site erythema (28%) and injection site pain (25%) were the most commonly reported non-serious AEs in children. Injection site erythema (32%), injection site pain (27%) and injection site swelling (23%) were the most commonly reported non-serious AEs in adults. Of serious reports (2129, 8% of total), fever was most commonly reported in both children (69%) and adults (39%). There were 66 reports of death, four in children and 62 in adults. Clinical review of death reports did not reveal any concerning patterns that would suggest a causal association with PPSV23. No disproportional reporting of unexpected AEs was observed in empirical Bayesian data mining. We did not identify any new or unexpected safety concerns for PPSV23. The VAERS data are consistent with safety data from pre-licensure clinical trials and other post-licensure studies. Published by Elsevier Ltd.

  14. Automatic and remote controlled ictal SPECT injection for seizure focus localization by use of a commercial contrast agent application pump.

    PubMed

    Feichtinger, Michael; Eder, Hans; Holl, Alexander; Körner, Eva; Zmugg, Gerda; Aigner, Reingard; Fazekas, Franz; Ott, Erwin

    2007-07-01

    In the presurgical evaluation of patients with partial epilepsy, the ictal single photon emission computed tomography (SPECT) is a useful noninvasive diagnostic tool for seizure focus localization. To achieve optimal SPECT scan quality, ictal tracer injection should be carried out as quickly as possible after the seizure onset and under highest safety conditions possible. Compared to the commonly used manual injection, an automatic administration of the radioactive tracer may provide higher quality standards for this procedure. In this study, therefore, we retrospectively analyzed efficiency and safety of an automatic injection system for ictal SPECT tracer application. Over a 31-month period, 26 patients underwent ictal SPECT by use of an automatic remote-controlled injection pump originally designed for CT-contrast agent application. Various factors were reviewed, including latency of ictal injection, radiation safety parameters, and ictal seizure onset localizing value. Times between seizure onset and tracer injection ranged between 3 and 48 s. In 21 of 26 patients ictal SPECT supported the localization of the epileptogenic focus in the course of the presurgical evaluation. In all cases ictal SPECT tracer injection was performed with a high degree of safety to patients and staff. Ictal SPECT by use of a remote-controlled CT-contrast agent injection system provides a high scan quality and is a safe and confirmatory presurgical evaluation technique in the epilepsy-monitoring unit.

  15. Intra-articular glucocorticoid injections in patients with juvenile idiopathic arthritis in a Singapore hospital.

    PubMed

    Leow, Olivia Min Yi; Lim, Lee Kean; Ooi, Pei Ling; Shek, Lynette Pei Chi; Ang, Elizabeth You Ning; Son, Mary Beth

    2014-05-01

    This study aimed to evaluate the efficacy and safety of intra-articular glucocorticoid (IAG) injections in our institution in children with juvenile idiopathic arthritis (JIA). This is a retrospective assessment of IAG injections performed by the Department of Paediatrics, National University Hospital, Singapore, from October 2009 to October 2011. A total of 26 procedures were evaluated for efficacy, considering parameters such as clinical response, changes in systemic medication, length of time between repeat injections, safety, consent-taking, pre- and post-procedural advice, compliance with aseptic technique, and post-procedural complications. A total of 26 IAG injections of triamcinolone hexacetonide were administered over 17 occasions (i.e. patient encounters) to ten patients with JIA during the study period. After the injections, clinical scoring by a paediatric rheumatologist showed overall improvement by an average of 2.62 points out of 15. Besides six patient encounters that had an increase in systemic medication on the day of the injection, five required an increase within six months post injection, two required no adjustments, and one resulted in a decrease in medications. In all, 21 injections did not require subsequent injections. The mean interval between repeat injections was 7.8 months. Cutaneous side effects were noted in three anatomically difficult joints. Medical documentation with regard to patient progress was found to be lacking. As per the recommendations of the American College of Rheumatology, we safely used IAG injections as the first-line therapy in our group of patients with oligoarticular JIA, and/or as an adjunct to systemic therapy in our patients with JIA.

  16. Passive injection control for microfluidic systems

    DOEpatents

    Paul, Phillip H.; Arnold, Don W.; Neyer, David W.

    2004-12-21

    Apparatus for eliminating siphoning, "dead" regions, and fluid concentration gradients in microscale analytical devices. In its most basic embodiment, the present invention affords passive injection control for both electric field-driven and pressure-driven systems by providing additional fluid flow channels or auxiliary channels disposed on either side of a sample separation column. The auxiliary channels are sized such that volumetric fluid flow rate through these channels, while sufficient to move the sample away from the sample injection region in a timely fashion, is less than that through the sample separation channel or chromatograph.

  17. Efficacy and safety of collagenase clostridium histolyticum injection for Dupuytren contracture: short-term results from 2 open-label studies.

    PubMed

    Witthaut, Jörg; Jones, Graeme; Skrepnik, Nebojsa; Kushner, Harvey; Houston, Anthony; Lindau, Tommy R

    2013-01-01

    The JOINT I (United States) and JOINT II (Australia and Europe) studies evaluated the efficacy and safety of collagenase clostridium histolyticum (CCH) injection for the treatment of Dupuytren contracture. Both studies used identical open-label protocols. Patients with fixed-flexion contractures of metacarpophalangeal (MCP) (20° to 100°) or proximal interphalangeal (PIP) joints (20° to 80°) could receive up to three 0.58-mg CCH injections per cord (up to 5 total injections per patient). We performed standardized finger extension procedures to disrupt injected cords the next day, with follow-up 1, 2, 6, and 9 months thereafter. The primary end point (clinical success) was reduction in contracture to within 0° to 5° of full extension 30 days after the last injection. Clinical improvement was defined as 50% or more reduction from baseline contracture. Dupuytren cords affecting 879 joints (531 MCP and 348 PIP) in 587 patients were administered CCH injections at 14 U.S. and 20 Australian/European sites, with similar outcomes in both studies. Clinical success was achieved in 497 (57%) of treated joints using 1.2 ± 0.5 (mean ± SD) CCH injections per cord. More MCP than PIP joints achieved clinical success (70% and 37%, respectively) or clinical improvement (89% and 58%, respectively). Less severely contracted joints responded better than those more severely contracted. Mean change in contracture was 55° for MCP joints and 25° for PIP joints. With average contracture reductions of 73% and improvements in range of motion by 30°, most patients (92%) were "very satisfied" (71%) or "quite satisfied" (21%) with treatment. Physicians rated change from baseline as "very much improved" (47%) or "much improved" (35%). The CCH injections were well tolerated, causing no tendon ruptures or systemic reactions. Collagenase clostridium histolyticum was an effective, minimally invasive option for the treatment of Dupuytren contracture of a broad range of severities. Most

  18. Manned space flight nuclear system safety. Volume 6: Space base nuclear system safety plan

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A qualitative identification of the steps required to assure the incorporation of radiological system safety principles and objectives into all phases of a manned space base program are presented. Specific areas of emphasis include: (1) radiological program management, (2) nuclear system safety plan implementation, (3) impact on program, and (4) summary of the key operation and design guidelines and requirements. The plan clearly indicates the necessity of considering and implementing radiological system safety recommendations as early as possible in the development cycle to assure maximum safety and minimize the impact on design and mission plans.

  19. NASA System Safety Handbook. Volume 1; System Safety Framework and Concepts for Implementation

    NASA Technical Reports Server (NTRS)

    Dezfuli, Homayoon; Benjamin, Allan; Everett, Christopher; Smith, Curtis; Stamatelatos, Michael; Youngblood, Robert

    2011-01-01

    System safety assessment is defined in NPR 8715.3C, NASA General Safety Program Requirements as a disciplined, systematic approach to the analysis of risks resulting from hazards that can affect humans, the environment, and mission assets. Achievement of the highest practicable degree of system safety is one of NASA's highest priorities. Traditionally, system safety assessment at NASA and elsewhere has focused on the application of a set of safety analysis tools to identify safety risks and formulate effective controls.1 Familiar tools used for this purpose include various forms of hazard analyses, failure modes and effects analyses, and probabilistic safety assessment (commonly also referred to as probabilistic risk assessment (PRA)). In the past, it has been assumed that to show that a system is safe, it is sufficient to provide assurance that the process for identifying the hazards has been as comprehensive as possible and that each identified hazard has one or more associated controls. The NASA Aerospace Safety Advisory Panel (ASAP) has made several statements in its annual reports supporting a more holistic approach. In 2006, it recommended that "... a comprehensive risk assessment, communication and acceptance process be implemented to ensure that overall launch risk is considered in an integrated and consistent manner." In 2009, it advocated for "... a process for using a risk-informed design approach to produce a design that is optimally and sufficiently safe." As a rationale for the latter advocacy, it stated that "... the ASAP applauds switching to a performance-based approach because it emphasizes early risk identification to guide designs, thus enabling creative design approaches that might be more efficient, safer, or both." For purposes of this preface, it is worth mentioning three areas where the handbook emphasizes a more holistic type of thinking. First, the handbook takes the position that it is important to not just focus on risk on an individual

  20. Performance and stability analysis of gas-injection enhanced natural circulation in heavy-liquid-metal-cooled systems

    NASA Astrophysics Data System (ADS)

    Yoo, Yeon-Jong

    The purpose of this study is to investigate the performance and stability of the gas-injection enhanced natural circulation in heavy-liquid-metal-cooled systems. The target system is STAR-LM, which is a 400-MWt-class advanced lead-cooled fast reactor under development by Argonne National Laboratory and Oregon State University. The primary loop of STAR-LM relies on natural circulation to eliminate main circulation pumps for enhancement of passive safety. To significantly increase the natural circulation flow rate for the incorporation of potential future power uprates, the injection of noncondensable gas into the coolant above the core is envisioned ("gas lift pump"). Reliance upon gas-injection enhanced natural circulation raises the concern of flow instability due to the relatively high temperature change in the reactor core and the two-phase flow condition in the riser. For this study, the one-dimensional flow field equations were applied to each flow section and the mixture models of two-phase flow, i.e., both the homogeneous and drift-flux equilibrium models were used in the two-phase region of the riser. For the stability analysis, the linear perturbation technique based on the frequency-domain approach was used by employing the Nyquist stability criterion and a numerical root search method. It has been shown that the thermal power of the STAR-LM natural circulation system could be increased from 400 up to 1152 MW with gas injection under the limiting void fraction of 0.30 and limiting coolant velocity of 2.0 m/s from the steady-state performance analysis. As the result of the linear stability analysis, it has turned out that the STAR-LM natural circulation system would be stable even with gas injection. In addition, through the parametric study, it has been found that the thermal inertia effects of solid structures such as fuel rod and heat exchanger tube should be considered in the stability analysis model. The results of this study will be a part of the

  1. Flow monitoring and control system for injection wells

    DOEpatents

    Corey, John C.

    1993-01-01

    A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.

  2. Flow monitoring and control system for injection wells

    DOEpatents

    Corey, J.C.

    1993-02-16

    A system for monitoring and controlling the injection rate of fluid by an injection well of an in-situ remediation system for treating a contaminated groundwater plume. The well is fitted with a gated insert, substantially coaxial with the injection well. A plurality of openings, some or all of which are equipped with fluid flow sensors and gates, are spaced along the insert. The gates and sensors are connected to a surface controller. The insert may extend throughout part of, or substantially the entire length of the injection well. Alternatively, the insert may comprise one or more movable modules which can be positioned wherever desired along the well. The gates are opened part-way at the start of treatment. The sensors monitor and display the flow rate of fluid passing through each opening on a controller. As treatment continues, the gates are opened to increase flow in regions of lesser flow, and closed to decrease flow in regions of greater flow, thereby approximately equalizing the amount of fluid reaching each part of the plume.

  3. Intra-articular glucocorticoid injections in patients with juvenile idiopathic arthritis in a Singapore hospital

    PubMed Central

    Leow, Olivia Min Yi; Lim, Lee Kean; Ooi, Pei Ling; Shek, Lynette Pei Chi; Ang, Elizabeth You Ning; Son, Mary Beth

    2014-01-01

    INTRODUCTION This study aimed to evaluate the efficacy and safety of intra-articular glucocorticoid (IAG) injections in our institution in children with juvenile idiopathic arthritis (JIA). METHODS This is a retrospective assessment of IAG injections performed by the Department of Paediatrics, National University Hospital, Singapore, from October 2009 to October 2011. A total of 26 procedures were evaluated for efficacy, considering parameters such as clinical response, changes in systemic medication, length of time between repeat injections, safety, consent-taking, pre- and post-procedural advice, compliance with aseptic technique, and post-procedural complications. RESULTS A total of 26 IAG injections of triamcinolone hexacetonide were administered over 17 occasions (i.e. patient encounters) to ten patients with JIA during the study period. After the injections, clinical scoring by a paediatric rheumatologist showed overall improvement by an average of 2.62 points out of 15. Besides six patient encounters that had an increase in systemic medication on the day of the injection, five required an increase within six months post injection, two required no adjustments, and one resulted in a decrease in medications. In all, 21 injections did not require subsequent injections. The mean interval between repeat injections was 7.8 months. Cutaneous side effects were noted in three anatomically difficult joints. Medical documentation with regard to patient progress was found to be lacking. CONCLUSION As per the recommendations of the American College of Rheumatology, we safely used IAG injections as the first-line therapy in our group of patients with oligoarticular JIA, and/or as an adjunct to systemic therapy in our patients with JIA. PMID:24862747

  4. Advanced information processing system: Fault injection study and results

    NASA Technical Reports Server (NTRS)

    Burkhardt, Laura F.; Masotto, Thomas K.; Lala, Jaynarayan H.

    1992-01-01

    The objective of the AIPS program is to achieve a validated fault tolerant distributed computer system. The goals of the AIPS fault injection study were: (1) to present the fault injection study components addressing the AIPS validation objective; (2) to obtain feedback for fault removal from the design implementation; (3) to obtain statistical data regarding fault detection, isolation, and reconfiguration responses; and (4) to obtain data regarding the effects of faults on system performance. The parameters are described that must be varied to create a comprehensive set of fault injection tests, the subset of test cases selected, the test case measurements, and the test case execution. Both pin level hardware faults using a hardware fault injector and software injected memory mutations were used to test the system. An overview is provided of the hardware fault injector and the associated software used to carry out the experiments. Detailed specifications are given of fault and test results for the I/O Network and the AIPS Fault Tolerant Processor, respectively. The results are summarized and conclusions are given.

  5. NASA Safety Manual. Volume 3: System Safety

    NASA Technical Reports Server (NTRS)

    1970-01-01

    This Volume 3 of the NASA Safety Manual sets forth the basic elements and techniques for managing a system safety program and the technical methods recommended for use in developing a risk evaluation program that is oriented to the identification of hazards in aerospace hardware systems and the development of residual risk management information for the program manager that is based on the hazards identified. The methods and techniques described in this volume are in consonance with the requirements set forth in NHB 1700.1 (VI), Chapter 3. This volume and future volumes of the NASA Safety Manual shall not be rewritten, reprinted, or reproduced in any manner. Installation implementing procedures, if necessary, shall be inserted as page supplements in accordance with the provisions of Appendix A. No portion of this volume or future volumes of the NASA Safety Manual shall be invoked in contracts.

  6. Steroid intracochlear distribution differs by administration method: Systemic versus intratympanic injection.

    PubMed

    Lee, Jong Joo; Jang, Jeong Hun; Choo, Oak-Sung; Lim, Hye Jin; Choung, Yun-Hoon

    2018-01-01

    Steroids have been widely used to treat inner-ear diseases such as sudden sensorineural hearing loss, tinnitus, and Meniere's disease. They can be given via either systemic or intratympanic (IT) injection. The purpose of the present study was to explore differences in intracochlear steroid distribution by the administration method employed (systemic vs. IT injection). Animal study. Twenty-three Sprague-Dawley rats were given fluorescein isothiocyanate-labeled dexamethasone (FITC-DEX) three times (on successive days) via intraperitoneal (IP) or IT injection. Cochlear uptake of FITC-DEX was evaluated via immunohistochemistry and flow cytometry at 6 hours, and 3 and 7 days after the final injection. FITC-DEX uptake was evident in spiral ganglion cells (SGs), the organ of Corti (OC), and the lateral walls (LWs), the basal turns of which were stained relatively prominently in both groups. Animals receiving IP injections exhibited higher FITC-DEX uptakes by the SGs and OC, whereas IT injection triggered higher-level FITC-DEX accumulation by the OC and LWs. Flow cytometry revealed that intracochlear FITC-DEX uptake by IT-injected animals was higher and more prolonged than in animals subjected to IP injections. We thus describe differences in cochlear steroid distributions after systemic and IT injections. This finding could help our understanding of the pharmacokinetics of steroids in the cochlea. NA. Laryngoscope, 128:189-194, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  7. An Apparatus for Measuring Rates of Discharge of a Fuel-Injection System

    NASA Technical Reports Server (NTRS)

    Dutee, Francis J

    1941-01-01

    A portable apparatus for rapidly determining rates of discharge of a fuel-injection system is described. Satisfactory operation of this apparatus with injection-pump speeds up to 2400 r.p.m was obtained. Rate-of-discharge tests were made with several cam-plunger-valve injection systems with long injection tubes. A check valve designed to reduce secondary discharges was tested. This check valve was operated with injection-pump speeds up to 2400 r.p.m without the occurrence of large secondary discharges.

  8. Comprehensive Lifecycle for Assuring System Safety

    NASA Technical Reports Server (NTRS)

    Knight, John C.; Rowanhill, Jonathan C.

    2017-01-01

    CLASS is a novel approach to the enhancement of system safety in which the system safety case becomes the focus of safety engineering throughout the system lifecycle. CLASS also expands the role of the safety case across all phases of the system's lifetime, from concept formation to decommissioning. As CLASS has been developed, the concept has been generalized to a more comprehensive notion of assurance becoming the driving goal, where safety is an important special case. This report summarizes major aspects of CLASS and contains a bibliography of papers that provide additional details.

  9. An Injectable, Self-Healing Hydrogel to Repair the Central Nervous System.

    PubMed

    Tseng, Ting-Chen; Tao, Lei; Hsieh, Fu-Yu; Wei, Yen; Chiu, Ing-Ming; Hsu, Shan-hui

    2015-06-17

    An injectable, self-healing hydrogel (≈1.5 kPa) is developed for healing nerve-system deficits. Neurosphere-like progenitors proliferate in the hydrogel and differentiate into neuron-like cells. In the zebrafish injury model, the central nervous system function is partially rescued by injection of the hydrogel and significantly rescued by injection of the neurosphere-laden hydrogel. The self-healing hydrogel may thus potentially repair the central nervous system. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. A Simple Carbon Dioxide Injection System for Photosynthetic Studies 12

    PubMed Central

    Oliver, David J.; Cameron, Stewart I.; Schaedle, Michail

    1974-01-01

    A simple carbon dioxide injection system has been developed for the maintenance of CO2 concentrations in semiclosed cuvette systems suitable for photosynthesis and gaseous pollutant studies. The device injects small volumes of pure carbon dioxide into the cuvette in response to a signal from an infrared gas analyzer. PMID:16658944

  11. Reduced injection pressures using a compressed air injection technique (CAIT): an in vitro study.

    PubMed

    Tsui, Ban C H; Knezevich, Mark P; Pillay, Jennifer J

    2008-01-01

    High injection pressures have been associated with intraneural injection and persistent neurological injury in animals. Our objective was to test whether a reported simple compressed air injection technique (CAIT) would limit the generation of injection pressures to below a suggested 1,034 mm Hg limit in an in vitro model. After ethics board approval, 30 consenting anesthesiologists injected saline into a semiclosed system. Injection pressures using 30 mL syringes connected to a 22 gauge needle and containing 20 mL of saline were measured for 60 seconds using: (1) a typical "syringe feel" method, and (2) CAIT, thereby drawing 10 mL of air above the saline and compressing this to 5 mL prior to and during injections. All anesthesiologists performed the syringe feel method before introduction and demonstration of CAIT. Using CAIT, no anesthesiologist generated pressures above 1,034 mm Hg, while 29 of 30 produced pressures above this limit at some time using the syringe feel method. The mean pressure using CAIT was lower (636 +/- 71 vs. 1378 +/- 194 mm Hg, P = .025), and the syringe feel method resulted in higher peak pressures (1,875 +/- 206 vs. 715 +/- 104 mm Hg, P = .000). This study demonstrated that CAIT can effectively keep injection pressures under 1,034 mm Hg in this in vitro model. Animal and clinical studies will be needed to determine whether CAIT will allow objective, real-time pressure monitoring. If high pressure injections are proven to contribute to nerve injury in humans, this technique may have the potential to improve the safety of peripheral nerve blocks.

  12. Safety and Efficacy of Intra-articular Injection of Platelet-Rich Plasma in Patients With Ankle Osteoarthritis.

    PubMed

    Fukawa, Taisuke; Yamaguchi, Satoshi; Akatsu, Yorikazu; Yamamoto, Yohei; Akagi, Ryuichiro; Sasho, Takahisa

    2017-06-01

    An intra-articular injection of platelet-rich plasma (PRP) may be an effective treatment for osteoarthritis (OA). However, its efficacy in ankle OA has not been investigated yet. The purpose of this study was to assess the safety and efficacy of an intra-articular injection of PRP in patients with ankle OA during a 24-week period. Twenty ankles of 20 patients with varus-type ankle OA who received intra-articular injections of PRP were evaluated. PRP was extracted from whole blood by using the double-spin technique. Three injections of 2-mL PRP were administered to the ankle at an interval of 2 weeks under ultrasonographic guidance. Adverse events and efficacy were assessed at 4, 12, and 24 weeks after the last injection. Clinical outcomes were assessed by using the visual analog scale (VAS) for pain, the Japanese Society for Surgery of the Foot (JSSF) ankle/hindfoot scale, and the Self-Administered Foot Evaluation Questionnaire (SAFE-Q). No serious adverse effects were observed during the follow-up period. The VAS and JSSF scale scores significantly decreased from baseline to 4, 12, and 24 weeks after treatment ( P < .001). The mean score in the pain-related subscale of the SAFE-Q significantly improved from baseline to 12 weeks after treatment ( P = .04). Overall, the amount of pain reduction was maximal at 12 weeks after the last injection, and the effect was reduced at 24 weeks. The patients with late-stage OA had worse scores in all outcomes than those with early-stage OA. Intra-articular injections of PRP resulted in no serious adverse effects and significantly reduced pain in the patients with ankle OA. PRP treatment can be safe and effective and may be an option in the treatment of ankle OA. Level IV, case series.

  13. 77 FR 70409 - System Safety Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ...-0060, Notice No. 2] 2130-AC31 System Safety Program AGENCY: Federal Railroad Administration (FRA... passenger railroads to develop and implement a system safety program (SSP) to improve the safety of their... Division, U.S. Department of Transportation, Federal Railroad Administration, Office of Railroad Safety...

  14. Design and development of a direct injection system for cryogenic engines

    NASA Astrophysics Data System (ADS)

    Mutumba, Angela; Cheeseman, Kevin; Clarke, Henry; Wen, Dongsheng

    2018-04-01

    The cryogenic engine has received increasing attention due to its promising potential as a zero-emission engine. In this study, a new robust liquid nitrogen injection system was commissioned and set up to perform high-pressure injections into an open vessel. The system is used for quasi-steady flow tests used for the characterisation of the direct injection process for cryogenic engines. An electro-hydraulic valve actuator provides intricate control of the valve lift, with a minimum cycle time of 3 ms and a frequency of up to 20 Hz. With additional sub-cooling, liquid phase injections from 14 to 94 bar were achieved. Results showed an increase in the injected mass with the increase in pressure, and decrease in temperature. The injected mass was also observed to increases linearly with the valve lift. Better control of the injection process, minimises the number of variables, providing more comparable and repeatable sets of data. Implications of the results on the engine performance were also discussed.

  15. Penetration and Duration of Fuel Sprays from a Pump Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Marsh, E T

    1931-01-01

    High-speed motion pictures were taken of individual fuel sprays from a pump injection system. The changes in the spray-tip penetration with changes in the pump speed, injection-valve opening and closing pressures, discharge-orifice area, injection-tube length and diameter, and pump throttle setting were measured. In addition, the effects of the variables on the time lag and duration of injection can be controlled by the dimensions of the injection tube, the area of the discharge orifice, and the injection-valve opening and closing pressures.

  16. Manned space flight nuclear system safety. Volume 5: Nuclear System safety guidelines. Part 1: Space base nuclear safety

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The design and operations guidelines and requirements developed in the study of space base nuclear system safety are presented. Guidelines and requirements are presented for the space base subsystems, nuclear hardware (reactor, isotope sources, dynamic generator equipment), experiments, interfacing vehicles, ground support systems, range safety and facilities. Cross indices and references are provided which relate guidelines to each other, and to substantiating data in other volumes. The guidelines are intended for the implementation of nuclear safety related design and operational considerations in future space programs.

  17. Supercritical fuel injection system

    NASA Technical Reports Server (NTRS)

    Marek, C. J.; Cooper, L. P. (Inventor)

    1980-01-01

    a fuel injection system for gas turbines is described including a pair of high pressure pumps. The pumps provide fuel and a carrier fluid such as air at pressures above the critical pressure of the fuel. A supercritical mixing chamber mixes the fuel and carrier fluid and the mixture is sprayed into a combustion chamber. The use of fuel and a carrier fluid at supercritical pressures promotes rapid mixing of the fuel in the combustion chamber so as to reduce the formation of pollutants and promote cleaner burning.

  18. U.S. Space Station Freedom waste fluid disposal system with consideration of hydrazine waste gas injection thrusters

    NASA Technical Reports Server (NTRS)

    Winters, Brian A.

    1990-01-01

    The results are reported of a study of various methods for propulsively disposing of waste gases. The options considered include hydrazine waste gas injection, resistojets, and eutectic salt phase change heat beds. An overview is given of the waste gas disposal system and how hydrozine waste gas injector thruster is implemented within it. Thruster performance for various gases are given and comparisons with currently available thruster models are made. The impact of disposal on station propellant requirements and electrical power usage are addressed. Contamination effects, reliability and maintainability assessments, safety issues, and operational scenarios of the waste gas thruster and disposal system are considered.

  19. Why system safety programs can fail

    NASA Technical Reports Server (NTRS)

    Hammer, W.

    1971-01-01

    Factors that cause system safety programs to fail are discussed from the viewpoint that in general these programs have not achieved their intended aims. The one item which is considered to contribute most to failure of a system safety program is a poor statement of work which consists of ambiguity, lack of clear definition, use of obsolete requirements, and pure typographical errors. It is pointed out that unless safety requirements are stated clearly, and where they are readily apparent as firm requirements, some of them will be overlooked by designers and contractors. The lack of clarity is stated as being a major contributing factor in system safety program failure and usually evidenced in: (1) lack of clear requirements by the procuring activity, (2) lack of clear understanding of system safety by other managers, and (3) lack of clear methodology to be employed by system safety engineers.

  20. Does the concept of safety culture help or hinder systems thinking in safety?

    PubMed

    Reiman, Teemu; Rollenhagen, Carl

    2014-07-01

    The concept of safety culture has become established in safety management applications in all major safety-critical domains. The idea that safety culture somehow represents a "systemic view" on safety is seldom explicitly spoken out, but nevertheless seem to linger behind many safety culture discourses. However, in this paper we argue that the "new" contribution to safety management from safety culture never really became integrated with classical engineering principles and concepts. This integration would have been necessary for the development of a more genuine systems-oriented view on safety; e.g. a conception of safety in which human, technological, organisational and cultural factors are understood as mutually interacting elements. Without of this integration, researchers and the users of the various tools and methods associated with safety culture have sometimes fostered a belief that "safety culture" in fact represents such a systemic view about safety. This belief is, however, not backed up by theoretical or empirical evidence. It is true that safety culture, at least in some sense, represents a holistic term-a totality of factors that include human, organisational and technological aspects. However, the departure for such safety culture models is still human and organisational factors rather than technology (or safety) itself. The aim of this paper is to critically review the various uses of the concept of safety culture as representing a systemic view on safety. The article will take a look at the concepts of culture and safety culture based on previous studies, and outlines in more detail the theoretical challenges in safety culture as a systems concept. The paper also presents recommendations on how to make safety culture more systemic. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. The aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    Reynard, W. D.

    1984-01-01

    The aviation safety reporting system, an accident reporting system, is presented. The system identifies deficiencies and discrepancies and the data it provides are used for long term identification of problems. Data for planning and policy making are provided. The system offers training in safety education to pilots. Data and information are drawn from the available data bases.

  2. The Efficacy and Safety of HA IDF Plus (with Lidocaine) Versus HA IDF (Without Lidocaine) in Nasolabial Folds Injection: A Randomized, Multicenter, Double-Blind, Split-Face Study.

    PubMed

    Lee, Jong-Hun; Kim, Seok-Hwan; Park, Eun-Soo

    2017-04-01

    Injection-related pain of dermal fillers is a consistent and bothersome problem for patients undergoing soft tissue augmentation. Reducing the pain could improve overall patient satisfaction. The purpose of this study was to compare the pain relief, efficacy, and safety of HA IDF plus containing lidocaine with HA IDF without lidocaine during correction of nasolabial folds (NLFs). Sixty-two subjects were enrolled in a randomized, multicenter, double-blind, split-face study of HA IDF plus and HA IDF for NLF correction. For split-face study, HA IDF plus was injected to one side of NLF, and HA IDF was injected to the other side. The first evaluation variable was the injection site pain measured using a 100-mm visual analogue scale (VAS). The second evaluation variables included the global aesthetic improvement scale, wrinkle severity rating scale, and adverse events. Immediately after injection, 91.94% of subjects experienced at least 10 mm decrease in VAS scores at the side injected with HA IDF plus compared with HA IDF, and the rate of subjects is statistically significant. The two fillers were not significantly different in safety profile or wrinkle correction during the follow-up visit. HA IDF plus significantly reduced the injection-related pain during NLFs correction compared with HA IDF without altering clinical outcomes or safety. Both HA IDF plus and HA IDF were considerably tolerated and most adverse reactions were mild and transient. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  3. NASA Aviation Safety Reporting System (ASRS)

    NASA Technical Reports Server (NTRS)

    Connell, Linda

    2011-01-01

    The NASA Aviation Safety Reporting System (ASRS) collects, analyzes, and distributes de-identified safety information provided through confidentially submitted reports from frontline aviation personnel. Since its inception in 1976, the ASRS has collected over 900,000 reports and has never breached the identity of the people sharing their information about events or safety issues. From this volume of data, the ASRS has released over 5,500 aviation safety alerts concerning potential hazards and safety concerns. The ASRS processes these reports, evaluates the information, and provides de-identified report information through the online ASRS Database at http://asrs.arc.nasa.gov. The NASA ASRS is also a founding member of the International Confidential Aviation Safety Systems (ICASS) group which is a collection of other national aviation reporting systems throughout the world. The ASRS model has also been replicated for application to improving safety in railroad, medical, fire fighting, and other domains. This presentation \\vill discuss confidential, voluntary, and non-punitive reporting systems and their advantages in providing information for safety improvements.

  4. NASA Aviation Safety Reporting System (ASRS)

    NASA Technical Reports Server (NTRS)

    Connell, Linda J.

    2017-01-01

    The NASA Aviation Safety Reporting System (ASRS) collects, analyzes, and distributes de-identified safety information provided through confidentially submitted reports from frontline aviation personnel. Since its inception in 1976, the ASRS has collected over 1.4 million reports and has never breached the identity of the people sharing their information about events or safety issues. From this volume of data, the ASRS has released over 6,000 aviation safety alerts concerning potential hazards and safety concerns. The ASRS processes these reports, evaluates the information, and provides selected de-identified report information through the online ASRS Database at http:asrs.arc.nasa.gov. The NASA ASRS is also a founding member of the International Confidential Aviation Safety Systems (ICASS) group which is a collection of other national aviation reporting systems throughout the world. The ASRS model has also been replicated for application to improving safety in railroad, medical, fire fighting, and other domains. This presentation will discuss confidential, voluntary, and non-punitive reporting systems and their advantages in providing information for safety improvements.

  5. High Pressure Coolant Injection (HPCI) System Risk-Based Inspection Guide for Browns Ferry Nuclear Power Station

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, S.; DiBiasio, A.; Gunther, W.

    1993-09-01

    The High Pressure Coolant Injection (HPCI) system has been examined from a risk perspective. A System Risk-Based Inspection Guide (S-RIG) has been developed as an aid to HPCI system inspections at the Browns Ferry Nuclear Power Plant, Units 1, 2 and 3. The role of. the HPCI system in mitigating accidents is discussed in this S-RIG, along with insights on identified risk-based failure modes which could prevent proper operation of the system. The S-RIG provides a review of industry-wide operating experience, including plant-specific illustrative examples to augment the PRA and operational considerations in identifying a catalogue of basic PRA failuremore » modes for the HPCI system. It is designed to be used as a reference for routine inspections, self-initiated safety system functional inspections (SSFIs), and the evaluation of risk significance of component failures at the nuclear power plant.« less

  6. Integrating system safety into the basic systems engineering process

    NASA Technical Reports Server (NTRS)

    Griswold, J. W.

    1971-01-01

    The basic elements of a systems engineering process are given along with a detailed description of what the safety system requires from the systems engineering process. Also discussed is the safety that the system provides to other subfunctions of systems engineering.

  7. 49 CFR 385.103 - Safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  8. 49 CFR 385.103 - Safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.103 Section 385.103... Safety Monitoring System for Mexico-Domiciled Carriers § 385.103 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  9. Development of integrated control system for smart factory in the injection molding process

    NASA Astrophysics Data System (ADS)

    Chung, M. J.; Kim, C. Y.

    2018-03-01

    In this study, we proposed integrated control system for automation of injection molding process required for construction of smart factory. The injection molding process consists of heating, tool close, injection, cooling, tool open, and take-out. Take-out robot controller, image processing module, and process data acquisition interface module are developed and assembled to integrated control system. By adoption of integrated control system, the injection molding process can be simplified and the cost for construction of smart factory can be inexpensive.

  10. 49 CFR 385.703 - Safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  11. 49 CFR 385.703 - Safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Safety monitoring system. 385.703 Section 385.703... Safety Monitoring System for Non-North American Carriers § 385.703 Safety monitoring system. (a) General... Vehicle Safety Standards (FMVSSs), and Hazardous Materials Regulations (HMRs). (b) Roadside monitoring...

  12. Safety and Acceptability of Community-Based Distribution of Injectable Contraceptives: A Pilot Project in Mozambique

    PubMed Central

    Jacinto, Ana; Mobaracaly, Mahomed Riaz; Ustáb, Momade Bay; Bique, Cassimo; Blazer, Cassandra; Weidert, Karen; Prata, Ndola

    2016-01-01

    ABSTRACT Mozambique has witnessed a climbing total fertility rate in the last 20 years. Nearly one-third of married women have an unmet need for family planning, but the supply of family planning services is not meeting the demand. This study aimed to explore the safety and effectiveness of training 2 cadres of community health workers—traditional birth attendants (TBAs) and agentes polivalentes elementares (APEs) (polyvalent elementary health workers)—to administer the injectable contraceptive depot-medroxyprogesterone acetate (DMPA), and to provide evidence to policy makers on the feasibility of expanding community-based distribution of DMPA in areas where TBAs and APEs are present. A total of 1,432 women enrolled in the study between February 2014 and April 2015. The majority (63% to 66%) of women in the study started using contraception for the first time during the study period, and most women (over 66%) did not report side effects at the 3-month and 6-month follow-up visits. Very few (less than 0.5%) experienced morbidities at the injection site on the arm. Satisfaction with the performance of TBAs and APEs was high and improved over the study period. Overall, the project showed a high continuation rate (81.1%) after 3 injections, with TBA clients having significantly higher continuation rates than APE clients after 3 months and after 6 months. Clients’ reported willingness to pay for DMPA (64%) highlights the latent demand for modern contraceptives. Given Mozambique’s largely rural population and critical health care workforce shortage, community-based provision of family planning in general and of injectable contraceptives in particular, which has been shown to be safe, effective, and acceptable, is of crucial importance. This study demonstrates that community-based distribution of injectable contraceptives can provide access to family planning to a large group of women that previously had little or no access. PMID:27651076

  13. Safety and Acceptability of Community-Based Distribution of Injectable Contraceptives: A Pilot Project in Mozambique.

    PubMed

    Jacinto, Ana; Mobaracaly, Mahomed Riaz; Ustáb, Momade Bay; Bique, Cassimo; Blazer, Cassandra; Weidert, Karen; Prata, Ndola

    2016-09-28

    Mozambique has witnessed a climbing total fertility rate in the last 20 years. Nearly one-third of married women have an unmet need for family planning, but the supply of family planning services is not meeting the demand. This study aimed to explore the safety and effectiveness of training 2 cadres of community health workers-traditional birth attendants (TBAs) and agentes polivalentes elementares (APEs) (polyvalent elementary health workers)-to administer the injectable contraceptive depot-medroxyprogesterone acetate (DMPA), and to provide evidence to policy makers on the feasibility of expanding community-based distribution of DMPA in areas where TBAs and APEs are present. A total of 1,432 women enrolled in the study between February 2014 and April 2015. The majority (63% to 66%) of women in the study started using contraception for the first time during the study period, and most women (over 66%) did not report side effects at the 3-month and 6-month follow-up visits. Very few (less than 0.5%) experienced morbidities at the injection site on the arm. Satisfaction with the performance of TBAs and APEs was high and improved over the study period. Overall, the project showed a high continuation rate (81.1%) after 3 injections, with TBA clients having significantly higher continuation rates than APE clients after 3 months and after 6 months. Clients' reported willingness to pay for DMPA (64%) highlights the latent demand for modern contraceptives. Given Mozambique's largely rural population and critical health care workforce shortage, community-based provision of family planning in general and of injectable contraceptives in particular, which has been shown to be safe, effective, and acceptable, is of crucial importance. This study demonstrates that community-based distribution of injectable contraceptives can provide access to family planning to a large group of women that previously had little or no access. © Jacinto et al.

  14. Dual nozzle single pump fuel injection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gonzalez, C.

    1992-02-25

    This patent describes an improvement in a fuel injection system in a stratified charge hybrid internal combustion engine including a main combustion chamber, a precombustion chamber connected with the main chamber, fuel injectors in the main combustion chamber and precombustion chamber which open at higher and lower pressure levels respectively to sequentially inject fuel into the prechamber and the main chamber, timed spark ignition means in the prechamber for ignition of the fuel-air mixture therein, and an engine driven and timed fuel injection pump having a variable output capacity that varies with power level position, the injection pump is suppliedmore » by a low pressure charging pump. The improvement comprises: a shuttle valve including a bore therein; a shuttle spool means positioned within the bore defining a prechamber supply chamber on one side thereof and a spool activation chamber on the opposite side thereof the spool means having a first and second position; biasing means urging the spool towards it first position with the spool actuation chamber at its minimum volume; first conduit means connecting charging pressure to the prechamber supply camber in the first position oil the spool means; second conduit means connecting the injection pump to spool actuation chamber; third conduit means connecting the spool actuating chamber with the main injector; forth conduit means connecting the prechamber supply chamber with the prechamber injector; the initial charge from the injection pump actuates the spool means from its fir to its second position.« less

  15. Dextranomer/hyaluronic acid endoscopic injection is effective in the treatment of intermediate and high grade vesicoureteral reflux in patients with complete duplex systems.

    PubMed

    Hunziker, Manuela; Mohanan, Nochiparambil; Puri, Prem

    2013-05-01

    Endoscopic subureteral injection of dextranomer/hyaluronic acid has become an established alternative to long-term antibiotic prophylaxis or surgical treatment for vesicoureteral reflux. We evaluated the effectiveness of endoscopic injection of dextranomer/hyaluronic acid in intermediate and high grade vesicoureteral reflux in patients with complete duplex collecting systems. A total of 123 children underwent endoscopic correction of intermediate or high grade vesicoureteral reflux using injection of dextranomer/hyaluronic acid into complete duplex systems between 2001 and 2010. Vesicoureteral reflux was diagnosed by voiding cystourethrogram, and dimercapto-succinic acid scan was performed to evaluate the presence of renal scarring. Followup ultrasound and voiding cystourethrogram were performed 3 months after the outpatient procedure and renal ultrasound thereafter every 2 years. Mean followup was 6.7 years. Complete duplex systems were unilateral in 110 patients and bilateral in 13. Reflux severity in the 136 refluxing units was grade II in 1 (0.7%), III in 52 (38.2%), IV in 61 (44.9%) and V in 22 (16.2%). Dimercapto-succinic acid scan revealed renal functional abnormalities in 63 children (51.2%). Vesicoureteral reflux resolved after the first endoscopic injection of dextranomer/hyaluronic acid in 93 ureters (68.4%), after a second injection in 35 (25.7%) and after a third injection in 8 (5.9%). Febrile urinary tract infection developed in 5 patients (4.1%) during followup. No patient required ureteral reimplantation or experienced significant complications. Our results confirm the safety and efficacy of endoscopic injection of dextranomer/hyaluronic acid in eradicating intermediate and high grade vesicoureteral reflux in patients with complete duplex systems. We recommend this minimally invasive, 15-minute outpatient procedure as a viable option for treating intermediate and high grade vesicoureteral reflux in patients with complete duplex collecting systems

  16. Fluid injection device for high-pressure systems

    NASA Technical Reports Server (NTRS)

    Copeland, E. J.; Ward, J. B.

    1970-01-01

    Screw activated device, consisting of a compressor, shielded replaceable ampules, a multiple-element rubber gland, and a specially constructed fluid line fitting, injects measured amounts of fluids into a pressurized system. It is sturdy and easily manipulated.

  17. [Post-marketing safety surveillance of Diemailing Kudiezi injection: real world study in 30 233 cases].

    PubMed

    Liao, Xing; Yu, Dan-Dan; Xie, Yan-Ming; Zhang, Yun-Ling; He, Yan; Zhang, Yin; Liu, Yan; Yi, Dan-Hui; Wang, Yong-Yan

    2017-08-01

    This study was aimed to obtain the incidence of adverse drug reaction (ADR) of Diemailing Kudiezi injection, explore its characteristics, related risk factors and application in real world. A prospective single cohort study was conducted from 25 hospitals (including Chinese medicine hospitals and Western medicine hospitals) for 4 years. 30 233 consecutive inpatients using Diemailing Kudiezi injection were observed. Their general information was analyzed by using statistic frequency description. Association rules were used to analyze the correlation between comorbidities or drug combinations; the influential factors for ADRs were initially screened by using cross contingency method and Chi-square test, and then Group LASSAO method was used for further analysis. 54 patients with adverse drug events and 30 patients with ADRs were reported among 30 233 patients, with a total ADR incidence of 0.099%[95%CI (0.06%, 0.13%)]. There were 27 patients identified as the "general" ADR, one patients with "severe" ADR (anaphylactic shock) and two patients with new ADRs. ADR occurred most in 30 min after using Diemailing Kudiezi injection, in a total of 16 patients. The most ADRs were palpitation, vomiting, chills, pruritus and rash, 6 times for each symptom. Diemailing Kudiezi injection was well tolerated in the general population. The overall incidence of adverse reactions was rare, with high safety. However, the real incidence of ADRs may be underestimated in this study, and the blood samples were not obtained for the patients, so further mechanism studies shall be conducted. Copyright© by the Chinese Pharmaceutical Association.

  18. System safety engineering analysis handbook

    NASA Technical Reports Server (NTRS)

    Ijams, T. E.

    1972-01-01

    The basic requirements and guidelines for the preparation of System Safety Engineering Analysis are presented. The philosophy of System Safety and the various analytic methods available to the engineering profession are discussed. A text-book description of each of the methods is included.

  19. Optomechatronic System For Automated Intra Cytoplasmic Sperm Injection

    NASA Astrophysics Data System (ADS)

    Shulev, Assen; Tiankov, Tihomir; Ignatova, Detelina; Kostadinov, Kostadin; Roussev, Ilia; Trifonov, Dimitar; Penchev, Valentin

    2015-12-01

    This paper presents a complex optomechatronic system for In-Vitro Fertilization (IVF), offering almost complete automation of the Intra Cytoplasmic Sperm Injection (ICSI) procedure. The compound parts and sub-systems, as well as some of the computer vision algorithms, are described below. System capabilities for ICSI have been demonstrated on infertile oocyte cells.

  20. The Evolution of System Safety at NASA

    NASA Technical Reports Server (NTRS)

    Dezfuli, Homayoon; Everett, Chris; Groen, Frank

    2014-01-01

    The NASA system safety framework is in the process of change, motivated by the desire to promote an objectives-driven approach to system safety that explicitly focuses system safety efforts on system-level safety performance, and serves to unify, in a purposeful manner, safety-related activities that otherwise might be done in a way that results in gaps, redundancies, or unnecessary work. An objectives-driven approach to system safety affords more flexibility to determine, on a system-specific basis, the means by which adequate safety is achieved and verified. Such flexibility and efficiency is becoming increasingly important in the face of evolving engineering modalities and acquisition models, where, for example, NASA will increasingly rely on commercial providers for transportation services to low-earth orbit. A key element of this objectives-driven approach is the use of the risk-informed safety case (RISC): a structured argument, supported by a body of evidence, that provides a compelling, comprehensible and valid case that a system is or will be adequately safe for a given application in a given environment. The RISC addresses each of the objectives defined for the system, providing a rational basis for making informed risk acceptance decisions at relevant decision points in the system life cycle.

  1. Penetration and Duration of Fuel Sprays from a Pump Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Marsh, E T

    1934-01-01

    High-speed motion pictures were taken of individual fuel sprays from a pump injection system. The changes in the spray-tip penetration with changes in the pump speed, injection-valve opening and closing pressures, discharge-orifice area, injection-tube length and diameter, and pump throttle setting were measured. The pump was used with and without a check valve. The results show that the penetration of the spray tip can be controlled by the dimensions of the injection tube, the area of the discharge orifice, and the injection-valve opening and closing pressures.

  2. Modelling safety of multistate systems with ageing components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kołowrocki, Krzysztof; Soszyńska-Budny, Joanna

    An innovative approach to safety analysis of multistate ageing systems is presented. Basic notions of the ageing multistate systems safety analysis are introduced. The system components and the system multistate safety functions are defined. The mean values and variances of the multistate systems lifetimes in the safety state subsets and the mean values of their lifetimes in the particular safety states are defined. The multi-state system risk function and the moment of exceeding by the system the critical safety state are introduced. Applications of the proposed multistate system safety models to the evaluation and prediction of the safty characteristics ofmore » the consecutive “m out of n: F” is presented as well.« less

  3. Safety of intracameral injection of gatifloxacin, levofloxacin on corneal endothelial structure and viability.

    PubMed

    Choi, Jin A; Chung, Sung Kun

    2009-10-01

    To investigate the safety of intracameral injection of gatifloxacin, levofloxacin in a rabbit model as prophylaxis against endophthalmitis. Twenty-four eyes of New Zealand white rabbits were randomly divided into 3 treatment groups: levofloxacin, gatifloxacin, and balanced salt solution (BSS) control groups. After 100 microL of each was injected into the anterior chamber, endothelial toxicity was evaluated by measuring the central corneal thicknesses and the clinical toxicity scores using a slit-lamp at post-procedure days 3 and 7. The percent of dead cells was determined by vital staining with alizarin red and trypan blue at 7 days after injection. Finally, in each group, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were performed for the evaluation of structural integrity. The toxicity scores were increased at post-procedure days 3 and 7, but the difference among the groups was not statistically significant (P = 0.661, 0.216, respectively). With regard to baseline corneal thickness, only the levofloxacin group exhibited a significant increase from baseline (P = 0.028), whereas the other treatment groups showed no difference from baseline (P = 0.128 in gatifloxacin, 0.161 in BSS group). The mean corneal endothelial damage was 0.81 +/- 0.31% in the levofloxacin group, 0.56 +/- 0.47% in the gatifloxacin group, and 0.53 +/- 0.52% in the BSS group, with no statistically significant difference noted among the groups (P = 0.582). SEM revealed a well-preserved hexagonal endothelial cell mosaic and normal microvilli on the endothelial cell surface in the gatifloxacin and control groups. However, the levofloxacin group showed slightly disintegrated cellular borders. TEM revealed that each group maintained normal intracellular organization, whereas the levofloxacin group exhibited slightly flat cell configuration with irregular folds on the apical cell surface. Intracameral injection of gatifloxacin and levofloxacin was nontoxic in terms of

  4. Mercury contamination study for flight system safety

    NASA Technical Reports Server (NTRS)

    Gorzynski, C. S., Jr.; Maycock, J. N.

    1972-01-01

    The effects and prevention of possible mercury pollution from the failure of solar electric propulsion spacecraft using mercury propellant were studied from tankage loading of post launch trajector injection. During preflight operations and initial flight mode there is little danger of mercury pollution if proper safety precautions are taken. Any spillage on the loading, mating, transportation, or launch pad areas is obvious and can be removed by vacuum cleaning soil and chemical fixing. Mercury spilled on Cape Kennedy ground soil will be chemically complexed and retained by the sandstone subsoil. A cover layer of sand or gravel on spilled mercury which has settled to the bottom of a water body adjacent to the system operation will control and eliminate the formation of toxic organic mercurials. Mercury released into the earth's atmosphere through leakage of a fireball will be diffused to low concentration levels. However, gas phase reactions of mercury with ozone could cause a local ozone depletion and result in serious ecological hazards.

  5. System safety education focused on industrial engineering

    NASA Technical Reports Server (NTRS)

    Johnston, W. L.; Morris, R. S.

    1971-01-01

    An educational program, designed to train students with the specific skills needed to become safety specialists, is described. The discussion concentrates on application, selection, and utilization of various system safety analytical approaches. Emphasis is also placed on the management of a system safety program, its relationship with other disciplines, and new developments and applications of system safety techniques.

  6. Evaluation of Biodistribution and Safety of Adenovirus Vectors Containing Group B Fibers after Intravenous Injection into Baboons

    PubMed Central

    NI, SHAOHENG; BERNT, KATHRIN; GAGGAR, ANUJ; LI, ZONG-YI; KIEM, HANS-PETER; LIEBER, ANDRÉ

    2005-01-01

    Vectors containing group B adenovirus (Ad) fibers are able to efficiently transduce gene therapy targets that are refractory to infection with standard Ad serotype 5 (Ad5) vectors, including malignant tumor cells, hematopoietic stem cells, and dendritic cells. Preliminary studies in mice indicate that, after intravenous injection, B-group fiber-containing Ads do not efficiently transduce most organs and cause less acute toxicity than Ad5 vectors. However, biodistribution and safety studies in mice are of limited value because the mouse analog of the B-group Ad receptor, CD46, is expressed only in the testis, whereas in humans, CD46 is expressed on all nucleated cells. Unlike mice, baboons have CD46 expression patterns and levels that closely mimic those in humans. We conducted a biodistribution and toxicity study of group B Ad fiber-containing vectors in baboons. Animals received phosphate-buffered saline, Ad5-bGal (a first-generation Ad5 vector), or B-group fiber-containing Ads (Ad5/35-bGal and Ad5/11-bGal) at a dose of 2 × 1012 VP/kg, and vector biodistribution and safety was analyzed over 3 days. The amount of Ad5/35-bGal and Ad5/11-bGal vector genomes was in most tissues one to three orders of magnitude below that of Ad5. Significant Ad5/35- and Ad5/11-mediated transgene (β-galactosidase) expression was seen only in the marginal zone of splenic follicles. Compared with the animal that received Ad5-bGal, all animals injected with B-group fiber-containing Ad vectors had lower elevations in serum proinflammatory cytokine levels. Gross and histopathology were normal in animals that received B-group Ad fiber-containing Ads, in contrast to the Ad5-infused animal, which showed widespread endothelial damage and inflammation. In a further study, a chimeric Ad5/35 vector carrying proapoptotic TRAIL and Ad E1A genes under tumor-specific regulation was well tolerated in a 30-day toxicity study. No major clinical, serologic, or pathologic abnormalities were noticed in

  7. Efficacy and Safety of Intravesical OnabotulinumtoxinA Injection in Patients with Detrusor Hyperactivity and Impaired Contractility

    PubMed Central

    Wang, Chung-Cheng; Lee, Cheng-Ling; Kuo, Hann-Chorng

    2016-01-01

    We investigated the efficacy and safety of intravesical onabotulinumtoxinA injection in patients with detrusor hyperactivity and impaired contractility (DHIC). Twenty-one patients with urodynamically proven DHIC and 21 age-matched patients with overactive bladder (OAB) with urodynamic detrusor overactivity were treated with intravesical injections of 100 U of onabotulinumtoxinA. The overactive bladder symptom score, urgency severity score, patient perception of bladder condition, global response assessment, voiding diary, and procedure-related adverse events (AE) at baseline, two weeks, one, three, and six months after treatment were assessed. The results showed that the subjective symptom scores improved significantly in both groups, and the scores did not differ between the groups. The decrease in urgency episodes and urgency urinary incontinence were noted in OAB patients but not in DHIC patients. Although the incidence of AEs was comparable between the groups, the therapeutic efficacy lasted for a mean of 4.9 ± 4.8 months in DHIC patients and 7.2 ± 3.3 months in OAB patients (p = 0.03). We concluded that the efficacy of intravesical onabotulinumtoxinA injection for DHIC patients was limited and short-term. Nevertheless, AEs did not increase in DHIC. Intravesical onabotulinumtoxinA might not be a good indication in patients with DHIC and high post-voiding residual urine. Physicians should inform patients of the potential benefits and risks of onabotulinumtoxinA injection for treatment of DHIC. PMID:26999209

  8. Methodology for the Randomised Injecting Opioid Treatment Trial (RIOTT): evaluating injectable methadone and injectable heroin treatment versus optimised oral methadone treatment in the UK

    PubMed Central

    Lintzeris, Nicholas; Strang, John; Metrebian, Nicola; Byford, Sarah; Hallam, Christopher; Lee, Sally; Zador, Deborah

    2006-01-01

    Whilst unsupervised injectable methadone and diamorphine treatment has been part of the British treatment system for decades, the numbers receiving injectable opioid treatment (IOT) has been steadily diminishing in recent years. In contrast, there has been a recent expansion of supervised injectable diamorphine programs under trial conditions in a number of European and North American cities, although the evidence regarding the safety, efficacy and cost effectiveness of this treatment approach remains equivocal. Recent British clinical guidance indicates that IOT should be a second-line treatment for those patients in high-quality oral methadone treatment who continue to regularly inject heroin, and that treatment be initiated in newly-developed supervised injecting clinics. The Randomised Injectable Opioid Treatment Trial (RIOTT) is a multisite, prospective open-label randomised controlled trial (RCT) examining the role of treatment with injected opioids (methadone and heroin) for the management of heroin dependence in patients not responding to conventional substitution treatment. Specifically, the study examines whether efforts should be made to optimise methadone treatment for such patients (e.g. regular attendance, supervised dosing, high oral doses, access to psychosocial services), or whether such patients should be treated with injected methadone or heroin. Eligible patients (in oral substitution treatment and injecting illicit heroin on a regular basis) are randomised to one of three conditions: (1) optimized oral methadone treatment (Control group); (2) injected methadone treatment; or (3) injected heroin treatment (with access to oral methadone doses). Subjects are followed up for 6-months, with between-group comparisons on an intention-to-treat basis across a range of outcome measures. The primary outcome is the proportion of patients who discontinue regular illicit heroin use (operationalised as providing >50% urine drug screens negative for markers of

  9. Systems Thinking and Patient Safety

    DTIC Science & Technology

    2005-01-01

    1 Prologue Systems Thinking and Patient Safety Paul M. Schyve Patient safety is a prominent theme in health care delivery today. This should... patient safety and a willingness to invest in patient safety research. This volume—published by the Agency for Healthcare Research and Quality (AHRQ...The recent advent of the health care field’s emphasis on patient safety came at a favorable time. One or two decades earlier, our response would have

  10. Nanodrugs: pharmacokinetics and safety

    PubMed Central

    Onoue, Satomi; Yamada, Shizuo; Chan, Hak-Kim

    2014-01-01

    To date, various nanodrug systems have been developed for different routes of administration, which include dendrimers, nanocrystals, emulsions, liposomes, solid lipid nanoparticles, micelles, and polymeric nanoparticles. Nanodrug systems have been employed to improve the efficacy, safety, physicochemical properties, and pharmacokinetic/pharmacodynamic profile of pharmaceutical substances. In particular, functionalized nanodrug systems can offer enhanced bioavailability of orally taken drugs, prolonged half-life of injected drugs (by reducing immunogenicity), and targeted delivery to specific tissues. Thus, nanodrug systems might lower the frequency of administration while providing maximized pharmacological effects and minimized systemic side effects, possibly leading to better therapeutic compliance and clinical outcomes. In spite of these attractive pharmacokinetic advantages, recent attention has been drawn to the toxic potential of nanodrugs since they often exhibit in vitro and in vivo cytotoxicity, oxidative stress, inflammation, and genotoxicity. A better understanding of the pharmacokinetic and safety characteristics of nanodrugs and the limitations of each delivery option is necessary for the further development of efficacious nanodrugs with high therapeutic potential and a wide safety margin. This review highlights the recent progress in nanodrug system development, with a focus on the pharmacokinetic advantages and safety challenges. PMID:24591825

  11. Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system.

    PubMed

    Gaudry, Adam J; Nai, Yi Heng; Guijt, Rosanne M; Breadmore, Michael C

    2014-04-01

    A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations and three anions in individual microchannels in under 40 s with limits of detection (LODs) ranging from 1.5 to 24 μM. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.

  12. Product Engineering Class in the Software Safety Risk Taxonomy for Building Safety-Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice; Victor, Daniel

    2008-01-01

    When software safety requirements are imposed on legacy safety-critical systems, retrospective safety cases need to be formulated as part of recertifying the systems for further use and risks must be documented and managed to give confidence for reusing the systems. The SEJ Software Development Risk Taxonomy [4] focuses on general software development issues. It does not, however, cover all the safety risks. The Software Safety Risk Taxonomy [8] was developed which provides a construct for eliciting and categorizing software safety risks in a straightforward manner. In this paper, we present extended work on the taxonomy for safety that incorporates the additional issues inherent in the development and maintenance of safety-critical systems with software. An instrument called a Software Safety Risk Taxonomy Based Questionnaire (TBQ) is generated containing questions addressing each safety attribute in the Software Safety Risk Taxonomy. Software safety risks are surfaced using the new TBQ and then analyzed. In this paper we give the definitions for the specialized Product Engineering Class within the Software Safety Risk Taxonomy. At the end of the paper, we present the tool known as the 'Legacy Systems Risk Database Tool' that is used to collect and analyze the data required to show traceability to a particular safety standard

  13. In-space propellant systems safety. Volume 3: System safety analysis

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The primary objective was to examine from a system safety viewpoint in-space propellant logistic elements and operations to define the potential hazards and to recommend means to reduce, eliminate or control them. A secondary objective was to conduct trade studies of specific systems or operations to determine the safest of alternate approaches.

  14. Efficacy and safety of point-of-care ultrasound-guided intra-articular corticosteroid joint injections in patients with haemophilic arthropathy.

    PubMed

    Martin, E J; Cooke, E J; Ceponis, A; Barnes, R F W; Moran, C M; Holle, S; Hughes, T H; Moore, R E; von Drygalski, A

    2017-01-01

    Intra-articular corticosteroid injections are standard of care for managing joint pain secondary to osteoarthritis or rheumatoid arthritis but are rarely used in haemophilic arthropathy. We have introduced and evaluated the efficacy and safety of ultrasound-guided corticosteroid injections for pain relief in patients with haemophilic arthropathy. Ultrasound-guided intra-articular injections performed on haemophilia patients at UCSD between March 2012 and January 2016 were analysed. Needle placement and injection (40 mg triamcinolone; 3-5 mL lidocaine) were performed with musculoskeletal ultrasound and Power Doppler. Analysis included patient demographics, joint-specific parameters such as tissue hypervascularity and effusions, pain relief, and procedure-associated complications. Forty-five injections (14 ankles, 13 elbows, 18 knees) were administered in 25 patients. Advanced arthropathy with hypervascularity and/or effusions was present in 91% and 61% of joints, respectively. Ninety-one per cent of injections resulted in pain relief which was significant in 84% (>30% reduction). Median pain score was reduced from 7 of 10 to 1 of 10 (P < 0.001), usually within 24 h. Median duration of pain relief was 8 weeks (range 1-16 weeks). Haemophilia B patients experienced longer periods of relief, and high Pettersson scores were associated with shorter duration of relief. There were no procedure-associated complications. Repeat ultrasound of eight joints within 4 weeks of injection demonstrated nearly complete resolution of hypervascularity. Point-of-care ultrasound enabled intra-articular corticosteroid injections that provided highly effective, safe, and relatively long-lasting pain relief in haemophilic arthropathy. This approach should be used to improve pain management in haemophilic arthropathy. © 2016 John Wiley & Sons Ltd.

  15. Voltage controlled nano-injection system for single-cell surgery

    PubMed Central

    Seger, R. Adam; Actis, Paolo; Penfold, Catherine; Maalouf, Michelle; Vilozny, Boaz; Pourmand, Nader

    2015-01-01

    Manipulation and analysis of single cells is the next frontier in understanding processes that control the function and fate of cells. Herein we describe a single-cell injection platform based on nanopipettes. The system uses scanning microscopy techniques to detect cell surfaces, and voltage pulses to deliver molecules into individual cells. As a proof of concept, we injected adherent mammalian cells with fluorescent dyes. PMID:22899383

  16. Voltage controlled nano-injection system for single-cell surgery.

    PubMed

    Adam Seger, R; Actis, Paolo; Penfold, Catherine; Maalouf, Michelle; Vilozny, Boaz; Pourmand, Nader

    2012-09-28

    Manipulation and analysis of single cells is the next frontier in understanding processes that control the function and fate of cells. Herein we describe a single-cell injection platform based on nanopipettes. The system uses scanning microscopy techniques to detect cell surfaces, and voltage pulses to deliver molecules into individual cells. As a proof of concept, we injected adherent mammalian cells with fluorescent dyes.

  17. Software system safety

    NASA Technical Reports Server (NTRS)

    Uber, James G.

    1988-01-01

    Software itself is not hazardous, but since software and hardware share common interfaces there is an opportunity for software to create hazards. Further, these software systems are complex, and proven methods for the design, analysis, and measurement of software safety are not yet available. Some past software failures, future NASA software trends, software engineering methods, and tools and techniques for various software safety analyses are reviewed. Recommendations to NASA are made based on this review.

  18. The Efficacy and Safety of Concurrent Collagenase Clostridium Histolyticum Injections for 2 Dupuytren Contractures in the Same Hand: A Prospective, Multicenter Study.

    PubMed

    Gaston, R Glenn; Larsen, Søren Erik; Pess, Gary M; Coleman, Stephen; Dean, Brian; Cohen, Brian M; Kaufman, Gregory J; Tursi, James P; Hurst, Lawrence C

    2015-10-01

    To evaluate efficacy and safety of concurrent administration of 2 collagenase clostridium histolyticum (CCH) injections to treat 2 joints in the same hand with Dupuytren fixed flexion contractures (FFCs). Patients with 2 or more contractures in the same hand caused by palpable cords participated in a 60-day, multicenter, open-label, phase 3b study. Two 0.58 mg CCH doses were injected into 1 or 2 cords in the same hand (1 injection per affected joint) during the same visit. Finger extension was performed approximately 24, 48, or 72 or more hours later. Changes in FFC and range of motion, incidence of clinical success (FFC ≤ 5°), and adverse events (AEs) were summarized. The study enrolled 715 patients (725 treated joint pairs), and 714 patients (724 joint pairs) were analyzed for efficacy. At day 31, mean total FFC (sum of 2 treated joints) decreased 74%, from 98° to 27°. Mean total range of motion increased from 90° to 156°. The incidence of clinical success was 65% in metacarpophalangeal joints and 29% in proximal interphalangeal joints. Most treatment-related AEs were mild to moderate, resolving without intervention; the most common were swelling of treated extremity, contusion, and pain in extremity. The incidence of skin lacerations was 22% (160 of 715). Efficacy and safety were similar regardless of time to finger extension. Collagenase clostridium histolyticum can be used to effectively treat 2 affected joints concurrently without a greater risk of AEs than treatment of a single joint, with the exception of skin laceration. The incidence of clinical success in this study after 1 injection per joint was comparable to phase 3 study results after 3 or more injections per joint. Two concurrent CCH injections may allow more rapid overall treatment of multiple affected joints, and the ability to vary the time between CCH injection and finger extension may allow physicians and patients greater flexibility with scheduling treatment. Copyright © 2015 American

  19. Efficacy and safety of injection with poly-L-lactic acid compared with hyaluronic acid for correction of nasolabial fold: a randomized, evaluator-blinded, comparative study.

    PubMed

    Hyun, M Y; Lee, Y; No, Y A; Yoo, K H; Kim, M N; Hong, C K; Chang, S E; Won, C H; Kim, B J

    2015-03-01

    Hyaluronic acid (HA) fillers and poly-L-lactic acid (PLA) fillers are frequently used to correct facial wrinkles. To compare the efficacy and safety of a novel injectable poly-L-lactic acid (PLA) filler and a well-studied biphasic HA filler for the treatment of moderate to severe nasolabial folds. In this multicentre, randomized, evaluator-blinded, comparative study, subjects were randomized for injections with PLA or HA into both nasolabial folds. Efficacy was determined by calculating the change in Wrinkle Severity Rating Scale (WSRS) relative to baseline. Local safety was assessed by reported adverse events. At week 24, mean improvement in WSRS from baseline was 2.09 ± 0.68 for the PLA side and 1.54 ± 0.65 for the HA side. Both injections were well tolerated, and the adverse reactions were mild and transient in most cases. PLA provides noninferior efficacy compared with HA 6 months after being used to treat moderate to severe nasolabial folds. © 2014 British Association of Dermatologists.

  20. Emulation study on system characteristic of high pressure common-rail fuel injection system for marine medium-speed diesel engine

    NASA Astrophysics Data System (ADS)

    Wang, Qinpeng; Yang, Jianguo; Xin, Dong; He, Yuhai; Yu, Yonghua

    2018-05-01

    In this paper, based on the characteristic analyzing of the mechanical fuel injection system for the marine medium-speed diesel engine, a sectional high-pressure common rail fuel injection system is designed, rated condition rail pressure of which is 160MPa. The system simulation model is built and the performance of the high pressure common rail fuel injection system is analyzed, research results provide the technical foundation for the system engineering development.

  1. Evaluation Of The Vehicle Radar Safety Systems Rashid Radar Safety Brake Collision Warning System, Final Report

    DOT National Transportation Integrated Search

    1988-02-01

    THIS EVALUATION OF THE VEHICLE RADAR SAFETY SYSTEMS? ANTI-COLLISION DEVICE (HEREAFTER VRSS) WAS UNDERTAKEN BY THE OPERATOR PERFORMANCE AND SAFETY ANALYSIS DIVISION OF THE TRANSPORTATION SYSTEMS CENTER AT THE REQUEST OF THE NATIONAL HIGHWAY TRAFFIC SA...

  2. The evaluation of the optimization design and application effect of same-well-injection-production technique’s injection-production circulatory system

    NASA Astrophysics Data System (ADS)

    Guoxing, Zheng; Minghu, Jiang; Hongliang, Gong; Nannan, Zhang; Jianguang, Wei

    2018-02-01

    According to basic principles of combining series of strata and demands of same-well injection-production technique, the optimization designing method of same-well injection-production technique’s injection-production circulatory system is given. Based on oil-water two-phase model with condition of arbitrarily well network, a dynamic forecast method for the application of same-well injection-production reservoir is established with considering the demands and capacity of same-well injection-production technique, sample wells are selected to launch the forecast evaluation and analysis of same-well injection-production reservoir application’s effect. Results show: single-test-well composite water cut decreases by 4.7% and test-well-group composite water cut decreases by 1.56% under the condition of basically invariant ground water injection rate. The method provides theoretical support for the proof of same-well injection-production technique’s reservoir development improving effect and further tests.

  3. Tracer-Encapsulated Solid Pellet (TESPEL) Injection System for the TJ-II Stellarator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamura, N.; McCarthy, K. J.; Hayashi, H.

    2016-01-01

    A tracer-encapsulated solid pellet (TESPEL) injection system for the TJ-II stellarator was recently developed. In order to reduce the time and cost for the development, we combined a TESPEL injector provided by National Institute for Fusion Science with an existing TJ-II cryogenic pellet injection system. Consequently, the TESPEL injection into the TJ-II plasma was successfully achieved, which was confirmed by several pellet diagnostics including a normal-incidence spectrometer for monitoring a tracer impurity behavior.

  4. [Safety and effectiveness of large dose compound Sophora flavescens Ait injection in the treatment of advanced malignant tumors].

    PubMed

    Li, Dao-rui; Lin, Hong-sheng

    2011-04-01

    To evaluate the effectiveness and safety of large dose compound Sophora flavescens Ait injection in the treatment of advanced malignant tumors. A non-randomized case control trial was conducted. Ninety six patients with pathologically confirmed advanced non-small-cell lung cancer, gastric cancer and colorectal cancer were divided into traditional Chinese medicine group and chemotherapy group, 48 cases each. Patients of the traditional Chinese medicine group received treatment with large dose of compound Sophora flavescens Ait injection (20 ml/d), and 21 days as a cycle. Forty-seven patients of the traditional Chinese medicine group and 46 patients of the chemotherapy group completed their treatment, respectively. The clinical benefit rate (CBR) in the traditional Chinese medicine group was 83.0%, significantly higher than that in the chemotherapy group (69.6%) (P < 0.01). The Karnofsky performance status and weight improvement in the traditional Chinese medicine group was superior to that in the chemotherapy group (P < 0.05). Except the skin irritation in one patient in the traditional Chinese medicine group, there were no other clinical adverse effects related with the large dose compound Sophora flavescens Ait injection. Large dose compound Sophora flavescens Ait injection in the treatment of advanced malignant tumors is safe and effective. The recommended dose is 20 ml/d.

  5. Online assay of bone specific alkaline phosphatase with a flow injection-bead injection system.

    PubMed

    Hartwell, Supaporn Kradtap; Somprayoon, Duangporn; Kongtawelert, Prachya; Ongchai, Siriwan; Arppornchayanon, Olarn; Ganranoo, Lucksagoon; Lapanantnoppakhun, Somchai; Grudpan, Kate

    2007-09-26

    Alkaline phosphatase (ALP) has been used as one of the biomarkers for bone resorption and liver diseases. Normally, total alkaline phosphatase is quantified along with other symptoms to determine the releasing source of the alkaline phosphatase. A semi-automated flow injection-bead injection system was proposed to conveniently and selectively assay bone alkaline phosphatase (BALP) based on its specific binding to wheat germ coated beads. Amount of BALP in serum was determined from the intensity of the yellow product produced from bound BALP on the retained beads and its substrate pNPP. The used beads were discarded and the fresh ones were introduced for the next analysis. The reaction cell was designed to be opened and closed using a computer controlled solenoid valve for a precise incubation time. The performance of the proposed system was evaluated by using it to assay BALP in human serum. The results were compared to those obtained by using a commercial ELISA kit. The system is proposed to be an easy and cost effective system for quantification of BALP as an alternative to batch wise wheat germ specific binding technique.

  6. A Taxonomy of Fallacies in System Safety Arguments

    NASA Technical Reports Server (NTRS)

    Greenwell, William S.; Knight, John C.; Holloway, C. Michael; Pease, Jacob J.

    2006-01-01

    Safety cases are gaining acceptance as assurance vehicles for safety-related systems. A safety case documents the evidence and argument that a system is safe to operate; however, logical fallacies in the underlying argument may undermine a system s safety claims. Removing these fallacies is essential to reduce the risk of safety-related system failure. We present a taxonomy of common fallacies in safety arguments that is intended to assist safety professionals in avoiding and detecting fallacious reasoning in the arguments they develop and review. The taxonomy derives from a survey of general argument fallacies and a separate survey of fallacies in real-world safety arguments. Our taxonomy is specific to safety argumentation, and it is targeted at professionals who work with safety arguments but may lack formal training in logic or argumentation. We discuss the rationale for the selection and categorization of fallacies in the taxonomy. In addition to its applications to the development and review of safety cases, our taxonomy could also support the analysis of system failures and promote the development of more robust safety case patterns.

  7. System safety management: A new discipline

    NASA Technical Reports Server (NTRS)

    Pope, W. C.

    1971-01-01

    The systems theory is discussed in relation to safety management. It is suggested that systems safety management, as a new discipline, holds great promise for reducing operating errors, conserving labor resources, avoiding operating costs due to mistakes, and for improving managerial techniques. It is pointed out that managerial failures or system breakdowns are the basic reasons for human errors and condition defects. In this respect, a recommendation is made that safety engineers stop visualizing the problem only with the individual (supervisor or employee) and see the problem from the systems point of view.

  8. Droplet-based microfluidic flow injection system with large-scale concentration gradient by a single nanoliter-scale injection for enzyme inhibition assay.

    PubMed

    Cai, Long-Fei; Zhu, Ying; Du, Guan-Sheng; Fang, Qun

    2012-01-03

    We described a microfluidic chip-based system capable of generating droplet array with a large scale concentration gradient by coupling flow injection gradient technique with droplet-based microfluidics. Multiple modules including sample injection, sample dispersion, gradient generation, droplet formation, mixing of sample and reagents, and online reaction within the droplets were integrated into the microchip. In the system, nanoliter-scale sample solution was automatically injected into the chip under valveless flow injection analysis mode. The sample zone was first dispersed in the microchannel to form a concentration gradient along the axial direction of the microchannel and then segmented into a linear array of droplets by immiscible oil phase. With the segmentation and protection of the oil phase, the concentration gradient profile of the sample was preserved in the droplet array with high fidelity. With a single injection of 16 nL of sample solution, an array of droplets with concentration gradient spanning 3-4 orders of magnitude could be generated. The present system was applied in the enzyme inhibition assay of β-galactosidase to preliminarily demonstrate its potential in high throughput drug screening. With a single injection of 16 nL of inhibitor solution, more than 240 in-droplet enzyme inhibition reactions with different inhibitor concentrations could be performed with an analysis time of 2.5 min. Compared with multiwell plate-based screening systems, the inhibitor consumption was reduced 1000-fold. © 2011 American Chemical Society

  9. Intrathecal Spread of Injectate Following an Ultrasound-Guided Selective C5 Nerve Root Injection in a Human Cadaver Model.

    PubMed

    Falyar, Christian R; Abercrombie, Caroline; Becker, Robert; Biddle, Chuck

    2016-04-01

    Ultrasound-guided selective C5 nerve root blocks have been described in several case reports as a safe and effective means to anesthetize the distal clavicle while maintaining innervation of the upper extremity and preserving diaphragmatic function. In this study, cadavers were injected with 5 mL of 0.5% methylene blue dye under ultrasound guidance to investigate possible proximal and distal spread of injectate along the brachial plexus, if any. Following the injections, the specimens were dissected and examined to determine the distribution of dye and the structures affected. One injection revealed dye extended proximally into the epidural space, which penetrated the dura mater and was present on the spinal cord and brainstem. Dye was noted distally to the divisions in 3 injections. The anterior scalene muscle and phrenic nerve were stained in all 4 injections. It appears unlikely that local anesthetic spread is limited to the nerve root following an ultrasound-guided selective C5 nerve root injection. Under certain conditions, intrathecal spread also appears possible, which has major patient safety implications. Additional safety measures, such as injection pressure monitoring, should be incorporated into this block, or approaches that are more distal should be considered for the acute pain management of distal clavicle fractures.

  10. Long-term efficacy and safety of self-intracavernous injection of prostaglandin E1 for treatment of erectile dysfunction in China.

    PubMed

    He, L; Wen, J; Jiang, X; Chen, H; Tang, Y

    2011-06-01

    The study evaluated the long-term efficacy and safety profiles of self-intracavernous injection of prostaglandin E1 (PGE1) for erectile dysfunction (ED). Four hundred and sixteen ED patients were treated with self-intracavernous injection of PGE1 from January 1998 to December 2007 in our outpatient service. Follow-up was made to investigate the efficacy and side effects of this treatment. It was found that 261 patients (62.7%) felt satisfied and kept using this treatment due to its advantages of satisfactory efficacy and reasonable expense. Twenty-seven of them (6.5%) got rid of PGE1 treatment after five times injections and did not need any other drugs to maintain satisfactory sexual lives. Two hundred and fourteen (51.4%) patients kept using this treatment for over 1 year, 26 (6.2%) over 5 years, 12 (2.9%) over 8 years and 7 (1.7%) over 10 years. The major complications of self-intracavernous injection of PGE1 include fibrosis of corpus cavernosum (three cases), ecchymosis associated with vascular injury due to injection (23 cases) and pain associated with injection (295 cases). There were no patients displaying priapism. It is concluded that self-intracavernous injection of PGE1 is a safe and effective treatment for ED with various aetiologies and a broad range of severity, and no serious complications were observed after long-term application. © 2011 Blackwell Verlag GmbH.

  11. Patient Safety and the Malpractice System.

    PubMed

    Swift, James Q

    2017-05-01

    The cost of health care in the United States and malpractice insurance has escalated greatly over the past 30 years. In an ideal world, the goals of the tort system would be aligned with efforts at improving safety. In fact, there is little evidence that the tort system and the processes of risk management and informed consent have improved patient safety. This article explores the disunion between patient safety and the malpractice system. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Inferior or double joint spaces injection versus superior joint space injection for temporomandibular disorders: a systematic review and meta-analysis.

    PubMed

    Li, Chunjie; Zhang, Yifan; Lv, Jun; Shi, Zongdao

    2012-01-01

    To compare the effect and safety of inferior or double temporomandibular joint spaces drug injection versus superior temporomandibular joint space injection in the treatment of temporomandibular disorders. MEDLINE (via Ovid, 1948 to March 2011), CENTRAL (Issue 1, 2011), Embase (1984 to March 2011), CBM (1978 to March 2011), and World Health Organization International Clinical Trials Registry Platform were searched electronically; relevant journals as well as references of included studies were hand-searched for randomized controlled trials comparing effect or safety of inferior or double joint spaces drug injection technique with those of superior space injection technique. Risk of bias assessment with the tool recommended by Cochrane Collaboration, reporting quality assessment with CONSORT and data extraction, were carried out independently by 2 reviewers. Meta-analysis was delivered with RevMan 5.0.23. Four trials with 349 participants were included. All the included studies had moderate risk of bias. Meta-analysis showed that inferior or double spaces injection technique could significantly increase 2.88 mm more maximal mouth opening (P = .0001) and alleviate pain intensity in the temporomandibular area on average by 9.01 mm visual analog scale scores (P = .0001) compared with superior space injection technique, but could not markedly change synthesized clinical index (P = .05) in the short term; nevertheless, they showed more beneficial maximal mouth opening (P = .002), pain relief (P < .0001), and synthesized clinical variable (P < .0001) in the long term than superior space injection. No serious adverse events were reported. Inferior or double temporomandibular joint spaces drug injection technique shows better effect than superior space injection technique, and their safety is affirmative. However, more high-quality studies are still needed to test and verify the evidence. Crown Copyright © 2012. Published by Elsevier Inc. All rights reserved.

  13. Safer Systems: A NextGen Aviation Safety Strategic Goal

    NASA Technical Reports Server (NTRS)

    Darr, Stephen T.; Ricks, Wendell R.; Lemos, Katherine A.

    2008-01-01

    The Joint Planning and Development Office (JPDO), is charged by Congress with developing the concepts and plans for the Next Generation Air Transportation System (NextGen). The National Aviation Safety Strategic Plan (NASSP), developed by the Safety Working Group of the JPDO, focuses on establishing the goals, objectives, and strategies needed to realize the safety objectives of the NextGen Integrated Plan. The three goal areas of the NASSP are Safer Practices, Safer Systems, and Safer Worldwide. Safer Practices emphasizes an integrated, systematic approach to safety risk management through implementation of formalized Safety Management Systems (SMS) that incorporate safety data analysis processes, and the enhancement of methods for ensuring safety is an inherent characteristic of NextGen. Safer Systems emphasizes implementation of safety-enhancing technologies, which will improve safety for human-centered interfaces and enhance the safety of airborne and ground-based systems. Safer Worldwide encourages coordinating the adoption of the safer practices and safer systems technologies, policies and procedures worldwide, such that the maximum level of safety is achieved across air transportation system boundaries. This paper introduces the NASSP and its development, and focuses on the Safer Systems elements of the NASSP, which incorporates three objectives for NextGen systems: 1) provide risk reducing system interfaces, 2) provide safety enhancements for airborne systems, and 3) provide safety enhancements for ground-based systems. The goal of this paper is to expose avionics and air traffic management system developers to NASSP objectives and Safer Systems strategies.

  14. Fexapotide triflutate: results of long-term safety and efficacy trials of a novel injectable therapy for symptomatic prostate enlargement.

    PubMed

    Shore, Neal; Tutrone, Ronald; Efros, Mitchell; Bidair, Mohamed; Wachs, Barton; Kalota, Susan; Freedman, Sheldon; Bailen, James; Levin, Richard; Richardson, Stephen; Kaminetsky, Jed; Snyder, Jeffrey; Shepard, Barry; Goldberg, Kenneth; Hay, Alan; Gange, Steven; Grunberger, Ivan

    2018-05-01

    These studies were undertaken to determine if fexapotide triflutate 2.5 mg transrectal injectable (FT) has significant long-term (LT) safety and efficacy for the treatment of benign prostatic hyperplasia (BPH). Two placebo controlled double-blind randomized parallel group trials with 995 BPH patients at 72 sites treated 3:2 FT:placebo, with open-label FT crossover (CO) re-injection in 2 trials n = 344 and long-term follow-up (LF) 2-6.75 years (mean 3.58 years, median 3.67 years; FT re-injection CO mean 4.27 years, median 4.42 years) were evaluated. 12 months post-treatment patients elected no further treatment, approved oral medications, FT, or interventional treatment. Primary endpoint variable was change in Symptom Score (IPSS) at 12 months and at LF. CO primary co-endpoints were 3-year incidence of (1) surgery for BPH in FT treated CO patients versus patients crossed over to oral BPH medications and (2) surgery or acute urinary retention in FT-treated CO placebo patients versus placebo patients crossed over to oral BPH medications. 28 CO secondary endpoints assessed surgical and symptomatic outcomes in FT reinjected patients versus conventional BPH medication CO and control subgroups at 2 and 3 years. FT injection had no significant safety differences from placebo. LF IPSS change from baseline was higher in FT treated patients compared to placebo (median FT group improvement - 5.2 versus placebo - 3.0, p < 0.0001). LF incidence of AUR (1.08% p = 0.0058) and prostate cancer (PCa) (1.1% p = 0.0116) were both reduced in FT treated patients. LF incidence of intervention for BPH was reduced in the FT group versus oral BPH medications (8.08% versus 27.85% at 3 years, p < 0.0001). LF incidence of intervention or AUR in placebo CO group with FT versus placebo CO group with oral medications was reduced (6.07% versus 33.3% at 3 years, p < 0.0001). 28/28 secondary efficacy endpoints were reached in LF CO re-injection studies. FT 2.5 mg is a safe

  15. Transportation systems safety hazard analysis tool (SafetyHAT) user guide (version 1.0)

    DOT National Transportation Integrated Search

    2014-03-24

    This is a user guide for the transportation system Safety Hazard Analysis Tool (SafetyHAT) Version 1.0. SafetyHAT is a software tool that facilitates System Theoretic Process Analysis (STPA.) This user guide provides instructions on how to download, ...

  16. Waterflooding injectate design systems and methods

    DOEpatents

    Brady, Patrick V.; Krumhansl, James L.

    2014-08-19

    A method of designing an injectate to be used in a waterflooding operation is disclosed. One aspect includes specifying data representative of chemical characteristics of a liquid hydrocarbon, a connate, and a reservoir rock, of a subterranean reservoir. Charged species at an interface of the liquid hydrocarbon are determined based on the specified data by evaluating at least one chemical reaction. Charged species at an interface of the reservoir rock are determined based on the specified data by evaluating at least one chemical reaction. An extent of surface complexation between the charged species at the interfaces of the liquid hydrocarbon and the reservoir rock is determined by evaluating at least one surface complexation reaction. The injectate is designed and is operable to decrease the extent of surface complexation between the charged species at interfaces of the liquid hydrocarbon and the reservoir rock. Other methods, apparatus, and systems are disclosed.

  17. Safety features of subcritical fluid fueled systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, C.R.

    1995-10-01

    Accelerator-driven transmutation technology has been under study at Los Alamos for several years for application to nuclear waste treatment, tritium production, energy generation, and recently, to the disposition of excess weapons plutonium. Studies and evaluations performed to date at Los Alamos have led to a current focus on a fluid-fuel, fission system operating in a neutron source-supported subcritical mode, using molten salt reactor technology and accelerator-driven proton-neutron spallation. In this paper, the safety features and characteristics of such systems are explored from the perspective of the fundamental nuclear safety objectives that any reactor-type system should address. This exploration is qualitativemore » in nature and uses current vintage solid-fueled reactors as a baseline for comparison. Based on the safety perspectives presented, such systems should be capable of meeting the fundamental nuclear safety objectives. In addition, they should be able to provide the safety robustness desired for advanced reactors. However, the manner in which safety objectives and robustness are achieved is very different from that associated with conventional reactors. Also, there are a number of safety design and operational challenges that will have to be addressed for the safety potential of such systems to be credible.« less

  18. Efficacy and safety of collagenase Clostridium histolyticum injection for Dupuytren contracture: report of 40 cases.

    PubMed

    Alberton, F; Corain, M; Garofano, A; Pangallo, L; Valore, A; Zanella, V; Adani, R

    2014-12-01

    Dupuytren's disease (DD) is a fibroproliferative pathology that affects the palmar aponeurosis causing the development of nodules and collagen cords and the progressive flexion of the fingers. The standard procedure is surgical fasciectomy, followed by high recurrence rates. Collagenase Clostridium histolyticum (CCH) injection represents an innovative noninvasive approach to the treatment of DD. This prospective study was designed to examine the efficacy and safety of CCH injection performed in the outpatient, using local anesthesia. Forty patients [32 metacarpophalangeal (MP), 8 proximal interphalangeal (PIP)] with Dupuytren's contracture of at least 20° for MP joint and any degree for PIP joint were included. The mean age was 66. All joints were treated with a single vial of collagenase injection and manual breaking of the cord 24 h after. All adverse effects (AEs) were monitored. Patients were checked 7, 30, 90, and 180 days after the injection. Primary endpoint was a reduction in digit contracture within 0°-5° of normal extension. Secondary endpoints were the improvement of range of motion, the evaluation of AEs incidence, and cost-effectiveness of collagenase treatment. About 67.5 % of patients obtained a clinical success. At 6 months, a further 7.5% attained the same result. The mean contracture of treated joints was 5.3º for MP and 6.8° for PIP joints. Twenty-three patients had one or more mild-to-moderate side effects. The use of collagenase appears to be an effective and safe method for the treatment of Dupuytren's contracture. Therapeutic success was achieved in a significant percentage of patients. The incidence of side effects was higher, but they were local reactions of short duration. The use of a single collagenase vial in patients treated in day surgery appears more cost-effective than surgery.

  19. 46 CFR 62.25-15 - Safety control systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ....35-50. Note: Safety control systems include automatic and manual safety trip controls and automatic... engines. (e) Automatic safety trip control systems must— (1) Be provided where there is an immediate... 46 Shipping 2 2011-10-01 2011-10-01 false Safety control systems. 62.25-15 Section 62.25-15...

  20. Elimination of fuel pressure fluctuation and multi-injection fuel mass deviation of high pressure common-rail fuel injection system

    NASA Astrophysics Data System (ADS)

    Li, Pimao; Zhang, Youtong; Li, Tieshuan; Xie, Lizhe

    2015-03-01

    The influence of fuel pressure fluctuation on multi-injection fuel mass deviation has been studied a lot, but the fuel pressure fluctuation at injector inlet is still not eliminated efficiently. In this paper, a new type of hydraulic filter consisting of a damping hole and a chamber is developed for elimination of fuel pressure fluctuation and multi-injection fuel mass deviation. Linear model of the improved high pressure common-rail system(HPCRS) including injector, the pipe connecting common-rail with injector and the hydraulic filter is built. Fuel pressure fluctuation at injector inlet, on which frequency domain analysis is conducted through fast Fourier transformation, is acquired at different target pressure and different damping hole diameter experimentally. The linear model is validated and can predict the natural frequencies of the system. Influence of damping hole diameter on fuel pressure fluctuation is analyzed qualitatively based on the linear model, and it can be inferred that an optimal diameter of the damping hole for elimination of fuel pressure fluctuation exists. Fuel pressure fluctuation and fuel mass deviation under different damping hole diameters are measured experimentally, and it is testified that the amplitude of both fuel pressure fluctuation and fuel mass deviation decreases first and then increases with the increasing of damping hole diameter. The amplitude of main injection fuel mass deviation can be reduced by 73% at most under pilot-main injection mode, and the amplitude of post injection fuel mass deviation can be reduced by 92% at most under main-post injection mode. Fuel mass of a single injection increases with the increasing of the damping hole diameter. The hydraulic filter proposed by this research can be potentially used to eliminate fuel pressure fluctuation at injector inlet and improve the stability of HPCRS fuel injection.

  1. Early Botulinum Toxin Injections in Infants With Musculoskeletal Disorders: A Systematic Review of Safety and Effectiveness.

    PubMed

    Bourseul, Jean-Sébastien; Molina, Anais; Lintanf, Mael; Houx, Laetitia; Chaléat-Valayer, Emmanuelle; Pons, Christelle; Brochard, Sylvain

    2018-06-01

    To report current evidence regarding the safety of intramuscular botulinum toxin injection (BTI) in children with orthopedic- and neurologic-related musculoskeletal disorders >2 years of age. PubMed, Cochrane Library, and ScienceDirect, Google Scholar, and Web of Science. Two reviewers independently selected studies based on predetermined inclusion criteria. Data relating to the aim were extracted. Methodologic quality was graded independently by 2 reviewers using the Physiotherapy Evidence Database scale for randomized controlled trials (RCTs) and the Downs and Black evaluation tool for non-RCTs. Level of evidence was determined using the modified Sackett scale. Data of 473 infants were analyzed. Fifty-five infants had cerebral palsy, 112 had obstetric brachial plexus palsy, 257 had clubfoot, and 44 had congenital torticollis. No studies reported any severe adverse event that could be attributed to the BTI. The rate of mild to moderate adverse events reported varied from 5% to 25%. Results regarding efficacy were preliminary, dependent on the pathology, and limited by the small number of studies and their low levels of evidence. BTI is already widely used as an early treatment for this age group. The safety profile of BTI in infants appears similar to that of older children and risks appear more related to the severity of the pathology and the location of the injections than to the toxin itself. Regarding effectiveness, other studies with higher levels of evidence should be carried out for each specific pathology. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. System theory and safety models in Swedish, UK, Dutch and Australian road safety strategies.

    PubMed

    Hughes, B P; Anund, A; Falkmer, T

    2015-01-01

    Road safety strategies represent interventions on a complex social technical system level. An understanding of a theoretical basis and description is required for strategies to be structured and developed. Road safety strategies are described as systems, but have not been related to the theory, principles and basis by which systems have been developed and analysed. Recently, road safety strategies, which have been employed for many years in different countries, have moved to a 'vision zero', or 'safe system' style. The aim of this study was to analyse the successful Swedish, United Kingdom and Dutch road safety strategies against the older, and newer, Australian road safety strategies, with respect to their foundations in system theory and safety models. Analysis of the strategies against these foundations could indicate potential improvements. The content of four modern cases of road safety strategy was compared against each other, reviewed against scientific systems theory and reviewed against types of safety model. The strategies contained substantial similarities, but were different in terms of fundamental constructs and principles, with limited theoretical basis. The results indicate that the modern strategies do not include essential aspects of systems theory that describe relationships and interdependencies between key components. The description of these strategies as systems is therefore not well founded and deserves further development. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Injection locked oscillator system for pulsed metal vapor lasers

    DOEpatents

    Warner, Bruce E.; Ault, Earl R.

    1988-01-01

    An injection locked oscillator system for pulsed metal vapor lasers is disclosed. The invention includes the combination of a seeding oscillator with an injection locked oscillator (ILO) for improving the quality, particularly the intensity, of an output laser beam pulse. The present invention includes means for matching the first seeder laser pulses from the seeding oscillator to second laser pulses of a metal vapor laser to improve the quality, and particularly the intensity, of the output laser beam pulse.

  4. Design an optimum safety policy for personnel safety management - A system dynamic approach

    NASA Astrophysics Data System (ADS)

    Balaji, P.

    2014-10-01

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamics model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making.

  5. Design an optimum safety policy for personnel safety management - A system dynamic approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balaji, P.

    2014-10-06

    Personnel safety management (PSM) ensures that employee's work conditions are healthy and safe by various proactive and reactive approaches. Nowadays it is a complex phenomenon because of increasing dynamic nature of organisations which results in an increase of accidents. An important part of accident prevention is to understand the existing system properly and make safety strategies for that system. System dynamics modelling appears to be an appropriate methodology to explore and make strategy for PSM. Many system dynamics models of industrial systems have been built entirely for specific host firms. This thesis illustrates an alternative approach. The generic system dynamicsmore » model of Personnel safety management was developed and tested in a host firm. The model was undergone various structural, behavioural and policy tests. The utility and effectiveness of model was further explored through modelling a safety scenario. In order to create effective safety policy under resource constraint, DOE (Design of experiment) was used. DOE uses classic designs, namely, fractional factorials and central composite designs. It used to make second order regression equation which serve as an objective function. That function was optimized under budget constraint and optimum value used for safety policy which shown greatest improvement in overall PSM. The outcome of this research indicates that personnel safety management model has the capability for acting as instruction tool to improve understanding of safety management and also as an aid to policy making.« less

  6. Subcutaneous injections: preventing needlestick injuries in the community.

    PubMed

    Aziz, Ann-Marie

    2012-06-01

    Community nurses provide care to patients in a variety of settings, for example health centres, community hospitals, patients' homes, residential and nursing homes. Administering subcutaneous injections to patients in the community is an everyday activity for many nurses in clinical practice. Many problems related to being 'sharps safe' are common to both community nurses and hospital staff. The majority of subcutaneous injections administered in the community are for patients with diabetes. Reducing needlestick injuries after the administration of subcutaneous injections in the community remains paramount to all NHS staff. This article provides information on what national standards to employ when administrating subcutaneous injections and what safety practices should be undertaken for good sharps management. Staff administering subcutaneous injections in the community need to ensure that they are updated on the latest developments in safety needle devices in order to prevent needlestick injuries and provide safe, effective and individualised care for their patients.

  7. Evaluation of safety in clinical use of generic paclitaxel [NK] for injection.

    PubMed

    Tsukiyama, Ikuto; Hotta, Kazuo; Takeuchi, Masayuki; Onishi, Masahumi; Toyama, Yukio; Saito, Hiroko; Sai, Yoshimichi; Miyamoto, Ken-Ichi; Hasegawa, Takaaki

    2012-04-01

    The introduction of generic drugs is a favored strategy in reducing medical costs, but some clinicians are often reluctant to use them because of lack of information with regard to their side effects. Generic paclitaxel [NK] differs from the proprietary version, Taxol®, in containing added citric acid and a more pure form of castor oil. However, little information exists regarding the effects of these additives on adverse events such as vascular pain, phlebitis, hypersensitivity and hepatic dysfunction. To compensate for this lack of information and to validate the safety of using generic paclitaxel, we investigated adverse events in response to generic paclitaxel [NK]. Our investigation focused on patients treated with both the proprietary formulation (Taxol® for injection) and the generic version(paclitaxel [NK] for injection)sequentially from April 2008 to March 2009. Adverse events were investigated retrospectively. Incidence of vascular pain, phlebitis and hypersensitivity was similar to that with the original product. Although the expression of some liver enzymes was slightly increased and some gastrointestinal events were reduced following generic paclitaxel [NK] treatment there was no statistically significant difference. The profiles of other adverse events were not significantly different. Increased vascular pain and phlebitis, predicted due to low pH conditions caused by citric acid, were not observed. Similarly, the pure castor oil included in generic paclitaxel [NK] did not influence hypersensitivity and hepatic function. We found no significant differences in our study of proprietary and generic paclitaxel [NK]. Thus, clinicians have no reason for prejudice against using generic paclitaxel [NK] on the basis of increased risk of side effects.

  8. Profiling safety of intravitreal injections for retinoblastoma using an anti-reflux procedure and sterilisation of the needle track.

    PubMed

    Munier, Francis L; Soliman, Sameh; Moulin, Alexandre P; Gaillard, Marie-Claire; Balmer, Aubin; Beck-Popovic, Maja

    2012-08-01

    The preservation of globe integrity has always been a major concern during the treatment of retinoblastoma for fear of extraocular or metastatic spread. Intravitreal chemotherapy has been attempted as a desperate salvage therapy only for eyes with refractory retinoblastoma. Published data on the safety and efficacy of this route are, however, limited. A modified technique of intravitreal injection in eyes with retinoblastoma is described. All children with retinoblastoma who received one or more intravitreal injections using this technique were retrospectively reviewed concerning ocular complications of the injection procedure as well as clinical or histopathological evidence of tumour spread. 30 eyes of 30 children with retinoblastoma received a total of 135 intravitreal injections, with a median follw-up duration of 13.5 months. No extraocular spread was seen on clinical follow-up in any patients and there was no tumour contamination of the retrieved entry sites histopathologically analysed among the five enucleated eyes. No significant ocular side effects were observed except transient localised vitreous haemorrhage (3/135). This technique is potentially safe and effective at a low cost and may play a promising role, especially in the treatment of recurrent and/or resistant vitreous disease in retinoblastoma, as an alternative to enucleation and/or external beam radiotherapy. However, this treatment should not replace the primary standard of care of retinoblastoma and should not be considered in group E eyes. Its application should be approved by an ophthalmological-oncological team and it should be performed by an experienced eye surgeon in a tertiary referral centre after careful selection of a tumour-free injection site.

  9. Autonomous Flight Safety System

    NASA Technical Reports Server (NTRS)

    Simpson, James

    2010-01-01

    The Autonomous Flight Safety System (AFSS) is an independent self-contained subsystem mounted onboard a launch vehicle. AFSS has been developed by and is owned by the US Government. Autonomously makes flight termination/destruct decisions using configurable software-based rules implemented on redundant flight processors using data from redundant GPS/IMU navigation sensors. AFSS implements rules determined by the appropriate Range Safety officials.

  10. [Analysis of clinical use of Danhong injection based on hospital information system].

    PubMed

    Chen, Qian; Yi, Danhui; Xie, Yanming; Yang, Wei; Yang, Wei; Zhuang, Yan; Du, Jing

    2011-10-01

    To know how Danhong injection is used in clinical practice and to provide a reference for guiding clinical use of Danhong Injection. Extract Danhong injection's post-marketing re-evaluation data from the Hospital Information System of ten three grade III-A General Hospitals in Beijing, use basic statistical analysis methods to analyze Danhong injection's indications, usage and dosage, days of treatment etc. in clinical practice. In patients using Danhong injection, there were more than 60 percent patients were prescribed based on main-diagnosis, first-visit and other diagnosis, which were also coincided with Danhong injection's instruction. In clinical practice, 95.5 percent of Danhong injection's administration routes conformed to the instruction and more than 90 percent of Danhong injection's dosage were within the limits prescribed by the instruction. Danhong injection was used less than 20 days successively. Danhong injection was used in combination with drugs with the action of removing blood stasis, antianginal drug, antiplatelet drug, drugs for cerebrovascular disease and so on. Danhong injection has been used according to instruction in practice almostly.

  11. System Safety in Aircraft Acquisition

    DTIC Science & Technology

    1984-01-01

    Relationship Between JSSC and SOHP ..... .......... 6- 1 Some Similarities in the Departments’ Approaches to System Safety... RELATIONSHIP BETWEEN JSSC AND SOHP The annual JSSC sponsored by the safety centers coordinates safety activities. It was described recently as "an unchartered...developed an excellent working relationship . Re- presentatives from SOHP can and do influence tasks undertaken by JSSC. Con- versely, SOUP is the one

  12. Industrial-grade silicone injections causing intermittent bilateral malar swelling: review of safety and efficacy of techniques and products available.

    PubMed

    Seward, Austin C; Meara, Daniel J

    2013-07-01

    Silicone and other fillers have become a popular aid to increase soft tissue density, decrease static skin rhytids, and treat muscle wasting, particularly in the face. As a result, injectable silicone has become popular in patients with the human immunodeficiency virus (HIV). It has been postulated that highly active antiretroviral therapy detrimentally induces the physiologic process of fat atrophy of the temporal and buccal fat pads of the face and regional fat wasting of the arms, legs, and buttocks and that HIV protease inhibitors may induce fat atrophy by binding and inhibiting homologous human proteins that are involved in fat metabolism. The classic hollowed-out facial appearance linked to HIV positivity can have detrimental social implications in infected patients who are otherwise very functional. In consequence, facial implantation, fat transplantation, and dermal and subcutaneous fillers have been used to aid in the restoration of facial appearance. This report describes the case of a patient who underwent multiple rounds of silicone injections and complained of intermittent facial swelling and pain long after the injections. The authors report on the safety of specific medical-grade injectable fillers and techniques found to be safely effective, especially in the HIV-positive population. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  13. System safety education focused on system management

    NASA Technical Reports Server (NTRS)

    Grose, V. L.

    1971-01-01

    System safety is defined and characteristics of the system are outlined. Some of the principle characteristics include role of humans in hazard analysis, clear language for input and output, system interdependence, self containment, and parallel analysis of elements.

  14. 76 FR 14592 - Safety Management System; Withdrawal

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-17

    ...-06A] RIN 2120-AJ15 Safety Management System; Withdrawal AGENCY: Federal Aviation Administration (FAA... (``product/ service providers'') to develop a Safety Management System (SMS). The FAA is withdrawing the... management with a set of robust decision-making tools to use to improve safety. The FAA received 89 comments...

  15. Database management systems for process safety.

    PubMed

    Early, William F

    2006-03-17

    Several elements of the process safety management regulation (PSM) require tracking and documentation of actions; process hazard analyses, management of change, process safety information, operating procedures, training, contractor safety programs, pre-startup safety reviews, incident investigations, emergency planning, and compliance audits. These elements can result in hundreds of actions annually that require actions. This tracking and documentation commonly is a failing identified in compliance audits, and is difficult to manage through action lists, spreadsheets, or other tools that are comfortably manipulated by plant personnel. This paper discusses the recent implementation of a database management system at a chemical plant and chronicles the improvements accomplished through the introduction of a customized system. The system as implemented modeled the normal plant workflows, and provided simple, recognizable user interfaces for ease of use.

  16. Nuclear Safety for Space Systems

    NASA Astrophysics Data System (ADS)

    Offiong, Etim

    2010-09-01

    It is trite, albeit a truism, to say that nuclear power can provide propulsion thrust needed to launch space vehicles and also, to provide electricity for powering on-board systems, especially for missions to the Moon, Mars and other deep space missions. Nuclear Power Sources(NPSs) are known to provide more capabilities than solar power, fuel cells and conventional chemical means. The worry has always been that of safety. The earliest superpowers(US and former Soviet Union) have designed and launched several nuclear-powered systems, with some failures. Nuclear failures and accidents, however little the number, could be far-reaching geographically, and are catastrophic to humans and the environment. Building on the numerous research works on nuclear power on Earth and in space, this paper seeks to bring to bear, issues relating to safety of space systems - spacecrafts, astronauts, Earth environment and extra terrestrial habitats - in the use and application of nuclear power sources. It also introduces a new formal training course in Space Systems Safety.

  17. Injection mode-locking Ti-sapphire laser system

    DOEpatents

    Hovater, James Curtis; Poelker, Bernard Matthew

    2002-01-01

    According to the present invention there is provided an injection modelocking Ti-sapphire laser system that produces a unidirectional laser oscillation through the application of a ring cavity laser that incorporates no intracavity devices to achieve unidirectional oscillation. An argon-ion or doubled Nd:YVO.sub.4 laser preferably serves as the pump laser and a gain-switched diode laser serves as the seed laser. A method for operating such a laser system to produce a unidirectional oscillating is also described.

  18. High pressure common rail injection system modeling and control.

    PubMed

    Wang, H P; Zheng, D; Tian, Y

    2016-07-01

    In this paper modeling and common-rail pressure control of high pressure common rail injection system (HPCRIS) is presented. The proposed mathematical model of high pressure common rail injection system which contains three sub-systems: high pressure pump sub-model, common rail sub-model and injector sub-model is a relative complicated nonlinear system. The mathematical model is validated by the software Matlab and a virtual detailed simulation environment. For the considered HPCRIS, an effective model free controller which is called Extended State Observer - based intelligent Proportional Integral (ESO-based iPI) controller is designed. And this proposed method is composed mainly of the referred ESO observer, and a time delay estimation based iPI controller. Finally, to demonstrate the performances of the proposed controller, the proposed ESO-based iPI controller is compared with a conventional PID controller and ADRC. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  19. 49 CFR 659.19 - System safety program plan: contents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false System safety program plan: contents. 659.19... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.19 System safety program plan: contents. The system safety plan shall...

  20. 49 CFR 659.19 - System safety program plan: contents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false System safety program plan: contents. 659.19... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.19 System safety program plan: contents. The system safety plan shall...

  1. 49 CFR 659.19 - System safety program plan: contents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false System safety program plan: contents. 659.19... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.19 System safety program plan: contents. The system safety plan shall...

  2. 49 CFR 659.19 - System safety program plan: contents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false System safety program plan: contents. 659.19... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.19 System safety program plan: contents. The system safety plan shall...

  3. 49 CFR 659.19 - System safety program plan: contents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false System safety program plan: contents. 659.19... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.19 System safety program plan: contents. The system safety plan shall...

  4. Safety climate and culture: Integrating psychological and systems perspectives.

    PubMed

    Casey, Tristan; Griffin, Mark A; Flatau Harrison, Huw; Neal, Andrew

    2017-07-01

    Safety climate research has reached a mature stage of development, with a number of meta-analyses demonstrating the link between safety climate and safety outcomes. More recently, there has been interest from systems theorists in integrating the concept of safety culture and to a lesser extent, safety climate into systems-based models of organizational safety. Such models represent a theoretical and practical development of the safety climate concept by positioning climate as part of a dynamic work system in which perceptions of safety act to constrain and shape employee behavior. We propose safety climate and safety culture constitute part of the enabling capitals through which organizations build safety capability. We discuss how organizations can deploy different configurations of enabling capital to exert control over work systems and maintain safe and productive performance. We outline 4 key strategies through which organizations to reconcile the system control problems of promotion versus prevention, and stability versus flexibility. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    Billings, C. E.; Lauber, J. K.; Funkhouser, H.; Lyman, E. G.; Huff, E. M.

    1976-01-01

    The origins and development of the NASA Aviation Safety Reporting System (ASRS) are briefly reviewed. The results of the first quarter's activity are summarized and discussed. Examples are given of bulletins describing potential air safety hazards, and the disposition of these bulletins. During the first quarter of operation, the ASRS received 1464 reports; 1407 provided data relevant to air safety. All reports are being processed for entry into the ASRS data base. During the reporting period, 130 alert bulletins describing possible problems in the aviation system were generated and disseminated. Responses were received from FAA and others regarding 108 of the alert bulletins. Action was being taken with respect to 70 of the 108 responses received. Further studies are planned of a number of areas, including human factors problems related to automation of the ground and airborne portions of the national aviation system.

  6. Health and safety management systems: liability or asset?

    PubMed

    Bennett, David

    2002-01-01

    Health and safety management systems have a background in theory and in various interests among employers and workplace health and safety professionals. These have resulted in a number of national systems emanating from national standard-writing centres and from employers' organizations. In some cases these systems have been recognized as national standards. The contenders for an international standard have been the International Organization of Standardization (ISO) and the International Labour Organization (ILO). The quality and environmental management systems of ISO indicate what an ISO health and safety management standard would look like. The ILO Guidelines on Safety and Health Management Systems, by contrast, are stringent, specific and potentially effective in improving health and safety performance in the workplace.

  7. Rates of fuel discharge as affected by the design of fuel-injection systems for internal-combustion engines

    NASA Technical Reports Server (NTRS)

    Gelalles, A G; Marsh, E T

    1933-01-01

    Using the method of weighing fuel collected in a receiver during a definite interval of the injection period, rates of discharge were determined, and the effects noted, when various changes were made in a fuel-injection system. The injection system consisted primarily of a by-pass controlled fuel pump and an automatic injection valve. The variables of the system studied were the pump speed, pump-throttle setting, discharge-orifice diameter, injection-valve opening and closing pressures, and injection-tube length and diameter.

  8. Quantitative safety assessment of air traffic control systems through system control capacity

    NASA Astrophysics Data System (ADS)

    Guo, Jingjing

    Quantitative Safety Assessments (QSA) are essential to safety benefit verification and regulations of developmental changes in safety critical systems like the Air Traffic Control (ATC) systems. Effectiveness of the assessments is particularly desirable today in the safe implementations of revolutionary ATC overhauls like NextGen and SESAR. QSA of ATC systems are however challenged by system complexity and lack of accident data. Extending from the idea "safety is a control problem" in the literature, this research proposes to assess system safety from the control perspective, through quantifying a system's "control capacity". A system's safety performance correlates to this "control capacity" in the control of "safety critical processes". To examine this idea in QSA of the ATC systems, a Control-capacity Based Safety Assessment Framework (CBSAF) is developed which includes two control capacity metrics and a procedural method. The two metrics are Probabilistic System Control-capacity (PSC) and Temporal System Control-capacity (TSC); each addresses an aspect of a system's control capacity. And the procedural method consists three general stages: I) identification of safety critical processes, II) development of system control models and III) evaluation of system control capacity. The CBSAF was tested in two case studies. The first one assesses an en-route collision avoidance scenario and compares three hypothetical configurations. The CBSAF was able to capture the uncoordinated behavior between two means of control, as was observed in a historic midair collision accident. The second case study compares CBSAF with an existing risk based QSA method in assessing the safety benefits of introducing a runway incursion alert system. Similar conclusions are reached between the two methods, while the CBSAF has the advantage of simplicity and provides a new control-based perspective and interpretation to the assessments. The case studies are intended to investigate the

  9. 49 CFR 659.15 - System safety program standard.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false System safety program standard. 659.15 Section 659... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the State Oversight Agency § 659.15 System safety program standard. (a) General requirement. Each state...

  10. Sterilization of slide sheath anesthetic injection systems placed within sharps containers.

    PubMed

    Palenik, C J; Burke, F J; Bose, M; Altweis, M L

    1997-01-01

    The purpose of this study was to evaluate the effect that two steam autoclaves and an unsaturated chemical vapor sterilizer had on killing bacterial endospores present on commercial spore strips or applied to sterile anesthetic injection systems placed within sharps containers. Three types of sterilizers were used: a gravity steam autoclave, a high vacuum steam autoclave and an unsaturated chemical vapor sterilizer. The microbial challenge for the sterilizers were Bacillus stearothermophilus spores present on commercial spore strips or drawn into and applied onto sliding sheath anesthetic injection systems with anesthetic carpules attached. Spore-soiled items were placed into the middle of sharps containers three-quarters-filled with representative clinical waste and sterilized. If, after culturing, sterilization of all test items in a group was not achieved, additional sterilization time was applied. Spore strips were killed within a single cycle of each sterilizer. Spore-soiled injection systems and carpules could not be routinely sterilized in the gravity steam autoclave or unsaturated chemical vapor sterilizers, even after three consecutive sterilization cycles. These items, however, were sterilized by exposure to a single-treatment cycle in a high-vacuum steam autoclave. Results indicate that routine sterilization of spore contaminated anesthetic carpules or injection systems could not be accomplished in a reasonable amount of time using sterilizers commonly found in dental offices.

  11. Safety status system for operating room devices.

    PubMed

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  12. Short-term outcome after intravitreal ranibizumab injections for the treatment of retinopathy of prematurity.

    PubMed

    Castellanos, María Ana Martínez; Schwartz, Shulamit; García-Aguirre, Gerardo; Quiroz-Mercado, Hugo

    2013-07-01

    To evaluate ocular outcome in premature infants treated with intravitreal ranibizumab injections for retinopathy of prematurity (ROP) over a period of 3 years. An interventional case series. Premature infants with high-risk prethreshold or threshold ROP with plus disease received an off label monotherapy with intravitreal injections of ranibizumab. The primary outcome was treatment success defined as regression of neovascularisation (NV) and absence of recurrence. The secondary outcomes were ocular and systemic adverse events and visual acuity. Six eyes were included in the study and treated with intravitreal injections of ranibizumab. All showed complete resolution of NV after a single injection. The anti-angiogenic intravitreal injections allowed for continued normal vessel growth into the peripheral retina, without any signs of disease recurrence or progression during the follow up period. No ocular or systemic adverse effects were observed. Three years of follow up in a small series suggest that intravitreal ranibizumab injections for ROP result in apparently preserved ocular outcome. Further large scale studies are needed to address the long-term safety and efficacy.

  13. [Developing traditional Chinese medicine injection is the need for curing sickness to save patients].

    PubMed

    He, Ping; Li, Feng-Jie; Li, Lian-da; Li, Yi-Kui

    2017-03-01

    Safety issues of traditional Chinese medicine injections has been heated debate. There are two diametrically opposed views: it should be used reasonable and developed healthily or be forbidden to use. Some people have many misunderstandings and prejudices about the safety of traditional Chinese medicine injections. Compared with western medicine,traditional Chinese medicine has its own particularity. Traditional Chinese medicine has complex components. Its research and clinical application is different from western medicine. Adverse reactions of traditional Chinese medicine injections are related to many factors,such as a large number of irrational use,blind use of traditional Chinese medicine injections and western medicine injections,counterfeit and substandard drugs,incorrect methods of intravenous infusion,toxicity of supplementary materials,drug ingredients. Developing traditional Chinese medicine injection is the need for curing sickness to save patients. The purposeful, targeted, organized and planned systematic research of traditional Chinese medicine injections should be strengthened,especially the safety of traditional Chinese medicine. Strengthen supervision and control of rational drug use.Strengthen the examination and approval,supervision and management of all aspects to ensure the safety of patients. Copyright© by the Chinese Pharmaceutical Association.

  14. 49 CFR 659.15 - System safety program standard.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... included in the affected rail transit agency's system safety program plan relating to the hazard management... 49 Transportation 7 2011-10-01 2011-10-01 false System safety program standard. 659.15 Section 659... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAIL FIXED GUIDEWAY SYSTEMS; STATE SAFETY OVERSIGHT Role of the...

  15. 46 CFR 62.25-15 - Safety control systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... manual safety trip controls must be provided for all main boilers, turbines, and internal combustion... 46 Shipping 2 2012-10-01 2012-10-01 false Safety control systems. 62.25-15 Section 62.25-15... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-15 Safety control systems. (a...

  16. 46 CFR 62.25-15 - Safety control systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... manual safety trip controls must be provided for all main boilers, turbines, and internal combustion... 46 Shipping 2 2013-10-01 2013-10-01 false Safety control systems. 62.25-15 Section 62.25-15... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-15 Safety control systems. (a...

  17. 46 CFR 62.25-15 - Safety control systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... manual safety trip controls must be provided for all main boilers, turbines, and internal combustion... 46 Shipping 2 2014-10-01 2014-10-01 false Safety control systems. 62.25-15 Section 62.25-15... AUTOMATION General Requirements for All Automated Vital Systems § 62.25-15 Safety control systems. (a...

  18. Systems pharmacology augments drug safety surveillance

    PubMed Central

    Lorberbaum, Tal; Nasir, Mavra; Keiser, Michael J.; Vilar, Santiago; Hripcsak, George; Tatonetti, Nicholas P.

    2014-01-01

    Small molecule drugs are the foundation of modern medical practice yet their use is limited by the onset of unexpected and severe adverse events (AEs). Regulatory agencies rely on post-marketing surveillance to monitor safety once drugs are approved for clinical use. Despite advances in pharmacovigilance methods that address issues of confounding bias, clinical data of AEs are inherently noisy. Systems pharmacology– the integration of systems biology and chemical genomics – can illuminate drug mechanisms of action. We hypothesize that these data can improve drug safety surveillance by highlighting drugs with a mechanistic connection to the target phenotype (enriching true positives) and filtering those that do not (depleting false positives). We present an algorithm, the modular assembly of drug safety subnetworks (MADSS), to combine systems pharmacology and pharmacovigilance data and significantly improve drug safety monitoring for four clinically relevant adverse drug reactions. PMID:25670520

  19. Design of a Coupled Thermoresponsive Hydrogel and Robotic System for Postinfarct Biomaterial Injection Therapy

    PubMed Central

    Fok, Kevin; Yoshizumi, Tomo; Park, Daewoo; Jiang, Hongbin; Schwartzman, David S.; Zenati, Marco A.; Uchibori, Takafumi

    2016-01-01

    Background In preclinical testing, ventricular wall injection of hydrogels has been shown to be effective in modulating ventricular remodeling and preserving cardiac function. For some approaches, early-stage clinical trials are under way. The hydrogel delivery method varies, with minimally invasive approaches being preferred. Endocardial injections carry a risk of hydrogel regurgitation into the circulation, and precise injection patterning is a challenge. An epicardial approach with a thermally gelling hydrogel through the subxiphoid pathway overcomes these disadvantages. Methods A relatively stiff, thermally responsive, injectable hydrogel based on N-isopropylacrylamide and N-vinylpyrrolidone (VP gel) was synthesized and characterized. VP gel thermal behavior was tuned to couple with a transepicardial injection robot, incorporating a cooling feature to achieve injectability. Ventricular wall injections of the optimized VP gel have been performed ex vivo and on beating porcine hearts. Results Thermal transition temperature, viscosity, and gelling time for the VP gel were manipulated by altering N-vinylpyrrolidone content. The target parameters for cooling in the robotic system were chosen by thermal modeling to support smooth, repeated injections on an ex vivo heart. Injections at predefined locations and depth were confirmed in an infarcted porcine model. Conclusions A coupled thermoresponsive hydrogel and robotic injection system incorporating a temperature-controlled injectate line was capable of targeted injections and amenable to use with a subxiphoid transepicardial approach for hydrogel injection after myocardial infarction. The confirmation of precise location and depth injections would facilitate a patient-specific planning strategy to optimize injection patterning to maximize the mechanical benefits of hydrogel placement. PMID:27154150

  20. 77 FR 16036 - Determination That CITANEST (Prilocaine Hydrochloride) Injection, 1%, 2%, and 3%, and CITANEST...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-19

    ... marketing for reasons other than safety or effectiveness. ANDAs that refer to CITANEST (prilocaine HCl... Hydrochloride) Injection, 4%, Were Not Withdrawn From Sale for Reasons of Safety or Effectiveness AGENCY: Food... (prilocaine HCl) Injection, 4%, were not withdrawn from sale for reasons of safety or effectiveness. This...

  1. Trinity cable safety system.

    DOT National Transportation Integrated Search

    2007-01-31

    Cab1eSafety System (CASS).is being tested by the Oklahoma Department of Transportation (ODOT) along I-35 in McClain County. CASS will be compare with two other system approve by ODOT. Using C-shaped post tensioned cables, CASS is designed to...

  2. Strontium-rich injectable hybrid system for bone regeneration.

    PubMed

    Neves, Nuno; Campos, Bruno B; Almeida, Isabel F; Costa, Paulo C; Cabral, Abel Trigo; Barbosa, Mário A; Ribeiro, Cristina C

    2016-02-01

    Current challenges in the development of scaffolds for bone regeneration include the engineering of materials that can withstand normal dynamic physiological mechanical stresses exerted on the bone and provide a matrix capable of supporting cell migration and tissue ingrowth. The objective of the present work was to develop and characterize a hybrid polymer–ceramic injectable system that consists of an alginate matrix crosslinked in situ in the presence of strontium(Sr), incorporating a ceramic reinforcement in the form of Sr-rich microspheres. The incorporation of Sr in the microspheres and in the vehicle relies on the growing evidence that Sr has beneficial effects in bone remodeling and in the treatment of osteopenic disorders and osteoporosis. Sr-rich porous hydroxyapatite microspheres with a uniform size and a mean diameter of 555 μm were prepared, and their compression strength and friability tested. A 3.5% (w/v) ultrapure sodium alginate solution was used as the vehicle and its in situ gelation was promoted by the addition of calcium (Ca) or Sr carbonate and Glucone-δ-lactone. Gelation times varied with temperature and crosslinking agent, being slower for Sr than for Ca, but adequate for injection in both cases. Injectability was evaluated using a device employed in vertebroplasty surgical procedures, coupled to a texture analyzer in compression mode. Compositions with 35%w of microspheres presented the best compromise between injectability and compression strength of the system, the force required to extrude it being lower than 100 N.Micro CT analysis revealed a homogeneous distribution of the microspheres inside the vehicle, and a mean inter-microspheres space of 220 μm. DMA results showed that elastic behavior of the hybrid is over the viscous one and that the higher storage modulus was obtained for the 3.5%Alg–35%Sr-HAp-Sr formulation.

  3. Racial/ethnic differences in obesity and comorbidities between safety-net- and non safety-net integrated health systems

    PubMed Central

    Balasubramanian, Bijal A.; Garcia, Michael P.; Corley, Douglas A.; Doubeni, Chyke A.; Haas, Jennifer S.; Kamineni, Aruna; Quinn, Virginia P.; Wernli, Karen; Zheng, Yingye; Skinner, Celette Sugg

    2017-01-01

    Abstract Previous research shows that patients in integrated health systems experience fewer racial disparities compared with more traditional healthcare systems. Little is known about patterns of racial/ethnic disparities between safety-net and non safety-net integrated health systems. We evaluated racial/ethnic differences in body mass index (BMI) and the Charlson comorbidity index from 3 non safety-net- and 1 safety-net integrated health systems in a cross-sectional study. Multinomial logistic regression modeled comorbidity and BMI on race/ethnicity and health care system type adjusting for age, sex, insurance, and zip-code-level income The study included 1.38 million patients. Higher proportions of safety-net versus non safety-net patients had comorbidity score of 3+ (11.1% vs. 5.0%) and BMI ≥35 (27.7% vs. 15.8%). In both types of systems, blacks and Hispanics were more likely than whites to have higher BMIs. Whites were more likely than blacks or Hispanics to have higher comorbidity scores in a safety net system, but less likely to have higher scores in the non safety-nets. The odds of comorbidity score 3+ and BMI 35+ in blacks relative to whites were significantly lower in safety-net than in non safety-net settings. Racial/ethnic differences were present within both safety-net and non safety-net integrated health systems, but patterns differed. Understanding patterns of racial/ethnic differences in health outcomes in safety-net and non safety-net integrated health systems is important to tailor interventions to eliminate racial/ethnic disparities in health and health care. PMID:28296752

  4. 49 CFR 385.715 - Duration of safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...

  5. 49 CFR 385.117 - Duration of safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...

  6. 49 CFR 385.117 - Duration of safety monitoring system.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 5 2011-10-01 2011-10-01 false Duration of safety monitoring system. 385.117... SAFETY FITNESS PROCEDURES Safety Monitoring System for Mexico-Domiciled Carriers § 385.117 Duration of safety monitoring system. (a) Each Mexico-domiciled carrier subject to this subpart will remain in the...

  7. 49 CFR 385.715 - Duration of safety monitoring system.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Duration of safety monitoring system. 385.715... SAFETY FITNESS PROCEDURES Safety Monitoring System for Non-North American Carriers § 385.715 Duration of safety monitoring system. (a) Each non-North America-domiciled carrier subject to this subpart will...

  8. Critical Characteristics of Radiation Detection System Components to be Dedicated for use in Safety Class and Safety Significant System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DAVIS, S.J.

    2000-05-25

    This document identifies critical characteristics of components to be dedicated for use in Safety Class (SC) or Safety Significant (SS) Systems, Structures, or Components (SSCs). This document identifies the requirements for the components of the common radiation area monitor alarm in the WESF pool cell. These are procured as Commercial Grade Items (CGI), with the qualification testing and formal dedication to be performed at the Waste Encapsulation Storage Facility (WESF), in safety class, safety significant systems. System modifications are to be performed in accordance with the instructions provided on ECN 658230. Components for this change are commercially available and interchangeablemore » with the existing alarm configuration This document focuses on the operational requirements for alarm, declaration of the safety classification, identification of critical characteristics, and interpretation of requirements for procurement. Critical characteristics are identified herein and must be verified, followed by formal dedication, prior to the components being used in safety related applications.« less

  9. Waterflooding injectate design systems and methods

    DOEpatents

    Brady, Patrick V.; Krumhansl, James L.

    2016-12-13

    A method of recovering a liquid hydrocarbon using an injectate includes recovering the liquid hydrocarbon through primary extraction. Physico-chemical data representative of electrostatic interactions between the liquid hydrocarbon and the reservoir rock are measured. At least one additive of the injectate is selected based on the physico-chemical data. The method includes recovering the liquid hydrocarbon from the reservoir rock through secondary extraction using the injectate.

  10. Overview of Energy Systems` safety analysis report programs. Safety Analysis Report Update Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-03-01

    The primary purpose of an Safety Analysis Report (SAR) is to provide a basis for judging the adequacy of a facility`s safety. The SAR documents the safety analyses that systematically identify the hazards posed by the facility, analyze the consequences and risk of potential accidents, and describe hazard control measures that protect the health and safety of the public and employees. In addition, some SARs document, as Technical Safety Requirements (TSRs, which include Technical Specifications and Operational Safety Requirements), technical and administrative requirements that ensure the facility is operated within prescribed safety limits. SARs also provide conveniently summarized information thatmore » may be used to support procedure development, training, inspections, and other activities necessary to facility operation. This ``Overview of Energy Systems Safety Analysis Report Programs`` Provides an introduction to the programs and processes used in the development and maintenance of the SARs. It also summarizes some of the uses of the SARs within Energy Systems and DOE.« less

  11. Analyzing Software Requirements Errors in Safety-Critical, Embedded Systems

    NASA Technical Reports Server (NTRS)

    Lutz, Robyn R.

    1993-01-01

    This paper analyzes the root causes of safety-related software errors in safety-critical, embedded systems. The results show that software errors identified as potentially hazardous to the system tend to be produced by different error mechanisms than non- safety-related software errors. Safety-related software errors are shown to arise most commonly from (1) discrepancies between the documented requirements specifications and the requirements needed for correct functioning of the system and (2) misunderstandings of the software's interface with the rest of the system. The paper uses these results to identify methods by which requirements errors can be prevented. The goal is to reduce safety-related software errors and to enhance the safety of complex, embedded systems.

  12. Use of liposomes as injectable-drug delivery systems.

    PubMed

    Ostro, M J; Cullis, P R

    1989-08-01

    The formation of liposomes and their application as delivery systems for injectable drugs are described. Liposomes are microscopic vesicles composed of one or more lipid membranes surrounding discrete aqueous compartments. These vesicles can encapsulate water-soluble drugs in their aqueous spaces and lipid-soluble drugs within the membrane itself. Liposomes release their contents by interacting with cells in one of four ways: adsorption, endocytosis, lipid exchange, or fusion. Liposome-entrapped drugs are distributed within the body much differently than free drugs; when administered intravenously to healthy animals and humans, most of the injected vesicles accumulate in the liver, spleen, lungs, bone marrow, and lymph nodes. Liposomes also accumulate preferentially at the sites of inflammation and infection and in some solid tumors; however, the reason for this accumulation is not clear. Four major factors influence liposomes' in vivo behavior and biodistribution: (1) liposomes tend to leak if cholesterol is not included in the vesicle membrane, (2) small liposomes are cleared more slowly than large liposomes, (3) the half-life of a liposome increases as the lipid dose increases, and (4) charged liposomal systems are cleared more rapidly than uncharged systems. The most advanced application of liposome-based therapy is in the treatment of systemic fungal infections, especially with amphotericin B. Liposomes are also under investigation for treatment of neoplastic disorders. Liposomes' uses in cancer therapy include encapsulation of known antineoplastic agents such as doxorubicin and methotrexate, delivery of immune modulators such as N-acetylmuramyl-L-alanine-D-isoglutamine, and encapsulation of new chemical entities that are synthesized with lipophilic segments tailored for insertion into lipid bilayers. Liposomal formulations of injectable antimicrobial agents and antineoplastic agents already are undergoing clinical testing, and most probably will receive

  13. Safety System Design for Technology Education. A Safety Guide for Technology Education Courses K-12.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh. Div. of Vocational Education.

    This manual is designed to involve both teachers and students in planning and controlling a safety system for technology education classrooms. The safety program involves students in the design and maintenance of the system by including them in the analysis of the classroom environment, job safety analysis, safety inspection, and machine safety…

  14. Implementation Procedure for STS Payloads, System Safety Requirements

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Guidelines and instructions for the implementation of the SP&R system safety requirements applicable to STS payloads are provided. The initial contact meeting with the payload organization and the subsequent safety reviews necessary to comply with the system safety requirements of the SP&R document are described. Waiver instructions are included for the cases in which a safety requirement cannot be met.

  15. Design of a Coupled Thermoresponsive Hydrogel and Robotic System for Postinfarct Biomaterial Injection Therapy.

    PubMed

    Zhu, Yang; Wood, Nathan A; Fok, Kevin; Yoshizumi, Tomo; Park, Dae Woo; Jiang, Hongbin; Schwartzman, David S; Zenati, Marco A; Uchibori, Takafumi; Wagner, William R; Riviere, Cameron N

    2016-09-01

    In preclinical testing, ventricular wall injection of hydrogels has been shown to be effective in modulating ventricular remodeling and preserving cardiac function. For some approaches, early-stage clinical trials are under way. The hydrogel delivery method varies, with minimally invasive approaches being preferred. Endocardial injections carry a risk of hydrogel regurgitation into the circulation, and precise injection patterning is a challenge. An epicardial approach with a thermally gelling hydrogel through the subxiphoid pathway overcomes these disadvantages. A relatively stiff, thermally responsive, injectable hydrogel based on N-isopropylacrylamide and N-vinylpyrrolidone (VP gel) was synthesized and characterized. VP gel thermal behavior was tuned to couple with a transepicardial injection robot, incorporating a cooling feature to achieve injectability. Ventricular wall injections of the optimized VP gel have been performed ex vivo and on beating porcine hearts. Thermal transition temperature, viscosity, and gelling time for the VP gel were manipulated by altering N-vinylpyrrolidone content. The target parameters for cooling in the robotic system were chosen by thermal modeling to support smooth, repeated injections on an ex vivo heart. Injections at predefined locations and depth were confirmed in an infarcted porcine model. A coupled thermoresponsive hydrogel and robotic injection system incorporating a temperature-controlled injectate line was capable of targeted injections and amenable to use with a subxiphoid transepicardial approach for hydrogel injection after myocardial infarction. The confirmation of precise location and depth injections would facilitate a patient-specific planning strategy to optimize injection patterning to maximize the mechanical benefits of hydrogel placement. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The human factors frequency considered a cause of or contributor to hazardous events onboard air carriers are examined with emphasis on distractions. Safety reports that have been analyzed, processed, and entered into the aviation safety reporting system data base are discussed. A sampling of alert bulletins and responses to them is also presented.

  17. Analysis of Aviation Safety Reporting System Incident Data Associated with the Technical Challenges of the System-Wide Safety and Assurance Technologies Project

    NASA Technical Reports Server (NTRS)

    Withrow, Colleen A.; Reveley, Mary S.

    2015-01-01

    The Aviation Safety Program (AvSP) System-Wide Safety and Assurance Technologies (SSAT) Project asked the AvSP Systems and Portfolio Analysis Team to identify SSAT-related trends. SSAT had four technical challenges: advance safety assurance to enable deployment of NextGen systems; automated discovery of precursors to aviation safety incidents; increasing safety of human-automation interaction by incorporating human performance, and prognostic algorithm design for safety assurance. This report reviews incident data from the NASA Aviation Safety Reporting System (ASRS) for system-component-failure- or-malfunction- (SCFM-) related and human-factor-related incidents for commercial or cargo air carriers (Part 121), commuter airlines (Part 135), and general aviation (Part 91). The data was analyzed by Federal Aviation Regulations (FAR) part, phase of flight, SCFM category, human factor category, and a variety of anomalies and results. There were 38 894 SCFM-related incidents and 83 478 human-factorrelated incidents analyzed between January 1993 and April 2011.

  18. 14 CFR 415.131 - Flight safety system crew data.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Flight safety system crew data. 415.131... Launch Vehicle From a Non-Federal Launch Site § 415.131 Flight safety system crew data. (a) An applicant's safety review document must identify each flight safety system crew position and the role of that...

  19. Development of a real-time chemical injection system for air-assisted variable-rate sprayers

    USDA-ARS?s Scientific Manuscript database

    A chemical injection system is an effective method to minimize chemical waste and reduce the environmental pollution in pesticide spray applications. A microprocessor controlled injection system implementing a ceramic piston metering pump was developed to accurately dispense chemicals to be mixed wi...

  20. Rapid assessment of injection practices in Cambodia, 2002

    PubMed Central

    Vong, Sirenda; Perz, Joseph F; Sok, Srun; Som, Seiharath; Goldstein, Susan; Hutin, Yvan; Tulloch, James

    2005-01-01

    Background Injection overuse and unsafe injection practices facilitate transmission of bloodborne pathogens such as hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Anecdotal reports of unsafe and unnecessary therapeutic injections and the high prevalence of HBV (8.0%), HCV (6.5%), and HIV (2.6%) infection in Cambodia have raised concern over injection safety. To estimate the magnitude and patterns of such practices, a rapid assessment of injection practices was conducted. Methods We surveyed a random sample of the general population in Takeo Province and convenience samples of prescribers and injection providers in Takeo Province and Phnom Penh city regarding injection-related knowledge, attitudes, and practices. Injection providers were observed administering injections. Data were collected using standardized methods adapted from the World Health Organization safe injection assessment guidelines. Results Among the general population sample (n = 500), the overall injection rate was 5.9 injections per person-year, with 40% of participants reporting receipt of ≥ 1 injection during the previous 6 months. Therapeutic injections, intravenous infusions, and immunizations accounted for 74%, 16% and 10% of injections, respectively. The majority (>85%) of injections were received in the private sector. All participants who recalled their last injection reported the injection was administered with a newly opened disposable syringe and needle. Prescribers (n = 60) reported that 47% of the total prescriptions they wrote included a therapeutic injection or infusion. Among injection providers (n = 60), 58% recapped the syringe after use and 13% did not dispose of the used needle and syringe appropriately. Over half (53%) of the providers reported a needlestick injury during the previous 12 months. Ninety percent of prescribers and injection providers were aware HBV, HCV, and HIV were transmitted through unsafe injection practices

  1. Dry low NOx combustion system with pre-mixed direct-injection secondary fuel nozzle

    DOEpatents

    Zuo, Baifang; Johnson, Thomas; Ziminsky, Willy; Khan, Abdul

    2013-12-17

    A combustion system includes a first combustion chamber and a second combustion chamber. The second combustion chamber is positioned downstream of the first combustion chamber. The combustion system also includes a pre-mixed, direct-injection secondary fuel nozzle. The pre-mixed, direct-injection secondary fuel nozzle extends through the first combustion chamber into the second combustion chamber.

  2. Cushion System for Multi-Use Child Safety Seat

    NASA Technical Reports Server (NTRS)

    Dabney, Richard W. (Inventor); Elrod, Susan V. (Inventor)

    2007-01-01

    A cushion system for use with a child safety seat has a plurality of bladders assembled to form a seat cushion that cooperates with the seat's safety harness. One or more sensors coupled to the safety harness sense tension therein and generate a signal indicative of the tension. Each of the bladders is individually pressurized by a pressurization system to define a support configuration of the seat cushion. The pressurization system is disabled when tension in the safety harness has attained a threshold level.

  3. Cushion system for multi-use child safety seat

    NASA Technical Reports Server (NTRS)

    Elrod, Susan V. (Inventor); Dabney, Richard W. (Inventor)

    2007-01-01

    A cushion system for use with a child safety seat has a plurality of bladders assembled to form a seat cushion that cooperates with the seat's safety harness. One or more sensors coupled to the safety harness sense tension therein and generate a signal indicative of the tension. Each of the bladders is individually pressurized by a pressurization system to define a support configuration of the seat cushion. The pressurization system is disabled when tension in the safety harness has attained a threshold level.

  4. Are nursing students safe when choosing gluteal intramuscular injection locations?

    PubMed

    Cornwall, J

    2011-01-01

    Nurses are required to perform gluteal intramuscular (IM) injections in practice. There are dangers associated with erroneous performance of this task, particularly with dorsogluteal injections. Knowledge regarding safe injection practice is therefore vital for nursing students. Fifty-eight second year students at a New Zealand Nursing School were given schematic drawings of the posterior and lateral aspects of the gluteal region. They were asked to mark and justify the safest location for gluteal IM injections. Fifty-seven students marked the dorsal schematic and one the lateral, with 38 (66.7%) marking in the upper outer quadrant (UOQ). Twenty indicating the UOQ (52.6%) wrote 'sciatic' or 'nerve' in justifying their location. Nineteen (33.3%) marked a location outside the UOQ; nine (47.4%) of these mentioned 'sciatic' or 'nerve' as reasons for injection safety. Overall, 50% of students mentioned 'sciatic' or 'nerve' in justifying the safety of their chosen injection location. Results suggest some second year nursing students do not understand safe gluteal IM injection locations and rationale. Current teaching practices and IM injection techniques could be revisited to prepare students more effectively; this may help prevent pathologies arising from this procedure.

  5. Local Food Systems Food Safety Concerns.

    PubMed

    Chapman, Benjamin; Gunter, Chris

    2018-04-01

    Foodborne disease causes an estimated 48 million illnesses and 3,000 deaths annually (Scallan E, et al., Emerg Infect Dis 17:7-15, 2011), with U.S. economic costs estimated at $152 billion to $1.4 trillion annually (Roberts T, Am J Agric Econ 89:1183-1188, 2007; Scharff RL, http://www.pewtrusts.org/en/research-and-analysis/reports/0001/01/01/healthrelated-costs-from-foodborne-illness-in-the-united-states, 2010). An increasing number of these illnesses are associated with fresh fruits and vegetables. An analysis of outbreaks from 1990 to 2003 found that 12% of outbreaks and 20% of outbreak-related illnesses were associated with produce (Klein S, Smith DeWaal CS, Center for Science in the Public Interest, https://cspinet.org/sites/default/files/attachment/ddreport.pdf, June 2008; Lynch M, Tauxe R, Hedberg C, Epidemiol Infect 137:307-315, 2009). These food safety problems have resulted in various stakeholders recommending the shift to a more preventative and risk-based food safety system. A modern risk-based food safety system takes a farm-to-fork preventative approach to food safety and relies on the proactive collection and analysis of data to better understand potential hazards and risk factors, to design and evaluate interventions, and to prioritize prevention efforts. Such a system focuses limited resources at the points in the food system with the likelihood of having greatest benefit to public health. As shared kitchens, food hubs, and local food systems such as community supported agriculture are becoming more prevalent throughout the United States, so are foodborne illness outbreaks at these locations. At these locations, many with limited resources, food safety methods of prevention are rarely the main focus. This lack of focus on food safety knowledge is why a growing number of foodborne illness outbreaks are occurring at these locations.

  6. Understanding patient safety performance and educational needs using the 'Safety-II' approach for complex systems.

    PubMed

    McNab, Duncan; Bowie, Paul; Morrison, Jill; Ross, Alastair

    2016-11-01

    Participation in projects to improve patient safety is a key component of general practice (GP) specialty training, appraisal and revalidation. Patient safety training priorities for GPs at all career stages are described in the Royal College of General Practitioners' curriculum. Current methods that are taught and employed to improve safety often use a 'find-and-fix' approach to identify components of a system (including humans) where performance could be improved. However, the complex interactions and inter-dependence between components in healthcare systems mean that cause and effect are not always linked in a predictable manner. The Safety-II approach has been proposed as a new way to understand how safety is achieved in complex systems that may improve quality and safety initiatives and enhance GP and trainee curriculum coverage. Safety-II aims to maximise the number of events with a successful outcome by exploring everyday work. Work-as-done often differs from work-as-imagined in protocols and guidelines and various ways to achieve success, dependent on work conditions, may be possible. Traditional approaches to improve the quality and safety of care often aim to constrain variability but understanding and managing variability may be a more beneficial approach. The application of a Safety-II approach to incident investigation, quality improvement projects, prospective analysis of risk in systems and performance indicators may offer improved insight into system performance leading to more effective change. The way forward may be to combine the Safety-II approach with 'traditional' methods to enhance patient safety training, outcomes and curriculum coverage.

  7. Top-Off Injection and Higher Currents at the Stanford Synchrotron Radiation Lightsource

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Johannes M.; Liu, James C.; Prinz, Alyssa A.

    2011-04-05

    The Stanford Synchrotron Radiation Lightsource (SSRL) at the SLAC National Accelerator Laboratory is a 234 m circumference storage ring for 3 GeV electrons with its synchrotron radiation serving currently 13 beamlines with about 27 experimental stations. It operated for long time with 100 mA peak current provided by usually three injections per day. In July 2009, the maximum beam current was raised to 200 mA. Over the period from June 2009 to March 2010, Top-Off operation started at every beamline. Top-Off, i.e., the injection of electrons into the storage ring with injection stoppers open, is necessary for SSRL to reachmore » its design current of 500 mA. In the future, the maximal power of the injection current will also soon be raised from currently 1.5 W to 5 W. The Radiation Protection Department at SLAC worked with SSRL on the specifications for the safety systems for operation with Top-Off injection and higher beam currents.« less

  8. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    During the third quarter of operation of the Aviation Safety Reporting System (ASRS), 1429 reports concerning aviation safety were received from pilots, air traffic controllers, and others in the national aviation system. Details of the administration and results of the program are discussed. The design and construction of the ASRS data base are briefly presented. Altitude deviations and potential aircraft conflicts associated with misunderstood clearances were studied and the results are discussed. Summary data regarding alert bulletins, examples of alert bulletins and responses to them, and a sample of deidentified ASRS reports are provided.

  9. System Safety in an IT Service Organization

    NASA Astrophysics Data System (ADS)

    Parsons, Mike; Scutt, Simon

    Within Logica UK, over 30 IT service projects are considered safetyrelated. These include operational IT services for airports, railway infrastructure asset management, nationwide radiation monitoring and hospital medical records services. A recent internal audit examined the processes and documents used to manage system safety on these services and made a series of recommendations for improvement. This paper looks at the changes and the challenges to introducing them, especially where the service is provided by multiple units supporting both safety and non-safety related services from multiple locations around the world. The recommendations include improvements to service agreements, improved process definitions, routine safety assessment of changes, enhanced call logging, improved staff competency and training, and increased safety awareness. Progress is reported as of today, together with a road map for implementation of the improvements to the service safety management system. A proposal for service assurance levels (SALs) is discussed as a way forward to cover the wide variety of services and associated safety risks.

  10. Aviation Safety Reporting System: Process and Procedures

    NASA Technical Reports Server (NTRS)

    Connell, Linda J.

    1997-01-01

    The Aviation Safety Reporting System (ASRS) was established in 1976 under an agreement between the Federal Aviation Administration (FAA) and the National Aeronautics and Space Administration (NASA). This cooperative safety program invites pilots, air traffic controllers, flight attendants, maintenance personnel, and others to voluntarily report to NASA any aviation incident or safety hazard. The FAA provides most of the program funding. NASA administers the program, sets its policies in consultation with the FAA and aviation community, and receives the reports submitted to the program. The FAA offers those who use the ASRS program two important reporting guarantees: confidentiality and limited immunity. Reports sent to ASRS are held in strict confidence. More than 350,000 reports have been submitted since the program's beginning without a single reporter's identity being revealed. ASRS removes all personal names and other potentially identifying information before entering reports into its database. This system is a very successful, proof-of-concept for gathering safety data in order to provide timely information about safety issues. The ASRS information is crucial to aviation safety efforts both nationally and internationally. It can be utilized as the first step in safety by providing the direction and content to informed policies, procedures, and research, especially human factors. The ASRS process and procedures will be presented as one model of safety reporting feedback systems.

  11. Efficacy and Safety of Levosulpiride Versus Haloperidol Injection in Patients With Acute Psychosis: A Randomized Double-Blind Study.

    PubMed

    Lavania, Sagar; Praharaj, Samir Kumar; Bains, Hariender Singh; Sinha, Vishal; Kumar, Abhinav

    2016-01-01

    Injectable antipsychotics are frequently required for controlling agitation and aggression in acute psychosis. No study has examined the use of injectable levosulpiride for this indication. To compare the efficacy and safety of injectable levosulpiride and haloperidol in patients with acute psychosis. This was a randomized, double-blind, parallel-group study in which 60 drug-naive patients having acute psychosis were randomly assigned to receive either intramuscular haloperidol (10-20 mg/d) or levosulpiride (25-50 mg/d) for 5 days. All patients were rated on Brief Psychiatric Rating Scale (BPRS), Overt Agitation Severity Scale (OASS), Overt Aggression Scale-Modified (OAS-M) scores, Simpson Angus Scale (SAS), and Barnes Akathisia Rating Scale (BARS). Repeated-measures ANOVA for BPRS scores showed significant effect of time (P < 0.001) and a trend toward greater reduction in scores in haloperidol group as shown by group × time interaction (P = 0.076). Repeated-measures ANOVA for OASS showed significant effect of time (P < 0.001) but no group × time interaction. Repeated-measures ANOVA for OAS-M scores showed significant effect of time (P < 0.001) and greater reduction in scores in haloperidol group as shown by group × time interaction (P = 0.032). Lorazepam requirement was much lower in haloperidol group as compared with those receiving levosulpiride (P = 0.022). Higher rates of akathisia and extrapyramidal symptoms were noted in the haloperidol group. Haloperidol was more effective than levosulpiride injection for psychotic symptoms, aggression, and severity of agitation in acute psychosis, but extrapyramidal adverse effects were less frequent with levosulpiride as compared with those receiving haloperidol.

  12. Secondary air injection system and method

    DOEpatents

    Wu, Ko-Jen; Walter, Darrell J.

    2014-08-19

    According to one embodiment of the invention, a secondary air injection system includes a first conduit in fluid communication with at least one first exhaust passage of the internal combustion engine and a second conduit in fluid communication with at least one second exhaust passage of the internal combustion engine, wherein the at least one first and second exhaust passages are in fluid communication with a turbocharger. The system also includes an air supply in fluid communication with the first and second conduits and a flow control device that controls fluid communication between the air supply and the first conduit and the second conduit and thereby controls fluid communication to the first and second exhaust passages of the internal combustion engine.

  13. An injectable particle-hydrogel hybrid system for glucose-regulatory insulin delivery.

    PubMed

    Zhao, Fuli; Wu, Di; Yao, Dan; Guo, Ruiwei; Wang, Weiwei; Dong, Anjie; Kong, Deling; Zhang, Jianhua

    2017-12-01

    Long-term and daily subcutaneous injections of insulin for the treatment of insulin-dependent diabetic patients often lead to poor patient compliance and undesired complications. Phenylboronic acid (PBA)-based polymeric hydrogels have been widely considered as one of the most promising insulin delivery system to replace the frequent insulin injections. However, their applications are limited by clinically irrelevant glucose-responsive range, slow response rate, low tissue-adhesiveness and poor biodegradability, undesirable leakage at normoglycemic state. Herein, we report a novel implantable insulin hydrogel for glucose-regulated delivery of insulin based on a unique particle-hydrogel hybrid platform featuring fast glucose responsiveness at physiological pH, shear-thinning behavior for injection, tissue-adhesive function for long-lasting adherence, and full biodegradability for safe use. The system was thoroughly characterized both in vitro and in vivo and was demonstrated to hold these unique functions. Using streptozotocin-induced diabetic mice as a model, it was shown that a single subcutaneous injection of the insulin-loaded particle-hydrogel formulation led to quasi-steady-state blood glucose levels within the normal range for about two weeks. In addition, the preparation of the formulation only involved simple mixing and self-assembling processes, and thus it had great scalability and reproducibility for practical use. The highly feasible preparation, excellent performance, inherent biocompatibility and biodegradability make this novel composite hydrogel promising platform for diabetes therapy. Phenylboronic acid (PBA)-based polymeric hydrogels have been widely considered as one of the most promising insulin delivery system to replace the frequent insulin injections. However, these hydrogels, mostly based on a variety of PBA-containing acrylamide monomers, are still far from clinical reality. Building upon a unique particle-hydrogel hybrid platform, herein we

  14. Post-licensure safety surveillance of zoster vaccine live (Zostavax®) in the United States, Vaccine Adverse Event Reporting System (VAERS), 2006-2015.

    PubMed

    Miller, Elaine R; Lewis, Paige; Shimabukuro, Tom T; Su, John; Moro, Pedro; Woo, Emily Jane; Jankosky, Christopher; Cano, Maria

    2018-03-26

    Herpes zoster (HZ), or shingles, is caused by reactivation of varicella-zoster virus in latently infected individuals. Live-attenuated HZ vaccine (zoster vaccine live, ZVL) is approved in the United States for persons aged ≥50 years and recommended by the CDC for persons ≥60 years. We analyzed U.S. reports of adverse events (AEs) following ZVL submitted to the Vaccine Adverse Event Reporting System (VAERS), a spontaneous reporting system to monitor vaccine safety, for persons vaccinated May 1, 2006, through January 31, 2015. We conducted descriptive analysis, clinical reviews of reports with selected pre-specified conditions, and empirical Bayesian data mining. VAERS received 23,092 reports following ZVL, of which 22,120 (96%) were classified as non-serious. Of reports where age was documented (n = 18,817), 83% were in persons aged ≥60 years. Reporting rates of AEs were 106 and 4.4 per 100,000 ZVL doses distributed for all reports and serious reports, respectively. When ZVL was administered alone among persons aged ≥50 years, injection site erythema (27%), HZ (17%), injection site swelling (17%), and rash (14%) were the most commonly reported symptoms among non-serious reports; HZ (29%), pain (18%), and rash (16%) were the most commonly reported symptoms among serious reports. Six reports included laboratory evidence of vaccine-strain varicella-zoster virus (Oka/Merck strain) infection; AEs included HZ, HZ- or varicella-like illness, and local reaction with vesicles. In our review of reports of death with sufficient information to determine cause (n = 46, median age 75 years), the most common causes were heart disease (n = 28), sepsis (n = 4), and stroke (n = 3). Empirical Bayesian data mining did not detect new or unexpected safety signals. Findings from our safety review of ZVL are consistent with those from pre-licensure clinical trials and other post-licensure assessments. Transient injection-site reactions, HZ, and rashes were most frequently

  15. Integrated therapy safety management system

    PubMed Central

    Podtschaske, Beatrice; Fuchs, Daniela; Friesdorf, Wolfgang

    2013-01-01

    Aims The aim is to demonstrate the benefit of the medico-ergonomic approach for the redesign of clinical work systems. Based on the six layer model, a concept for an ‘integrated therapy safety management’ is drafted. This concept could serve as a basis to improve resilience. Methods The concept is developed through a concept-based approach. The state of the art of safety and complexity research in human factors and ergonomics forms the basis. The findings are synthesized to a concept for ‘integrated therapy safety management’. The concept is applied by way of example for the ‘medication process’ to demonstrate its practical implementation. Results The ‘integrated therapy safety management’ is drafted in accordance with the six layer model. This model supports a detailed description of specific work tasks, the corresponding responsibilities and related workflows at different layers by using the concept of ‘bridge managers’. ‘Bridge managers’ anticipate potential errors and monitor the controlled system continuously. If disruptions or disturbances occur, they respond with corrective actions which ensure that no harm results and they initiate preventive measures for future procedures. The concept demonstrates that in a complex work system, the human factor is the key element and final authority to cope with the residual complexity. The expertise of the ‘bridge managers’ and the recursive hierarchical structure results in highly adaptive clinical work systems and increases their resilience. Conclusions The medico-ergonomic approach is a highly promising way of coping with two complexities. It offers a systematic framework for comprehensive analyses of clinical work systems and promotes interdisciplinary collaboration. PMID:24007448

  16. Twin-Screw Extruder Development for the ITER Pellet Injection System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitner, Steven J; Baylor, Larry R; Combs, Stephen Kirk

    The ITER pellet injection system is comprised of devices to form and accelerate pellets, and will be connected to inner wall guide tubes for fueling, and outer wall guide tubes for ELM pacing. An extruder will provide a stream of solid hydrogen isotopes to a secondary section, where pellets are cut and accelerated with a gas gun into the plasma. The ITER pellet injection system is required to provide a plasma fueling rate of 120 Pa-m3/s (900 mbar-L/s) and durations of up to 3000 s. The fueling pellets will be injected at a rate up to 10 Hz and pelletsmore » used to trigger ELMs will be injected at higher rates up to 20 Hz. A twin-screw extruder for the ITER pellet injection system is under development at the Oak Ridge National Laboratory. A one-fifth ITER scale prototype has been built and has demonstrated the production of a continuous solid deuterium extrusion. The 27 mm diameter, intermeshed, counter-rotating extruder screws are rotated at a rate up to ≈5 rpm. Deuterium gas is pre-cooled and liquefied and solidified in separate extruder barrels. The precooler consists of a deuterium gas filled copper coil suspended in a separate stainless steel vessel containing liquid nitrogen. The liquefier is comprised of a copper barrel connected to a Cryomech AL330 cryocooler, which has a machined helical groove surrounded by a copper jacket, through which the pre-cooled deuterium condenses. The lower extruder barrel is connected to a Cryomech GB-37 cryocooler to solidify the deuterium (at ≈15 K) before it is forced through the extruder die. The die forms the extrusion to a 3 mm x 4 mm rectangular cross section. Design improvements have been made to improve the pre-cooler and liquefier heat exchangers, to limit the loss of extrusion through gaps in the screws. This paper will describe the design improvements for the next iteration of the extruder prototype.« less

  17. [Clinical outcomes research of use of Shenfu injection based on hospital information system].

    PubMed

    Yang, Jing; Zhao, Ruo-Qi; Xie, Yan-Ming; Yang, Hu; Li, Lin; Zhuang, Yan

    2012-09-01

    To know how Shenfu injection is used in clinical practice and to provide a reference for guiding clinical use of Shenfu injection. Extract Shenfu injection's post-marketing re-evaluation data from the hospital information system (HIS) of 20 national grade III-A General Hospitals, use basic statistical analysis methods to analyze Shenfu injection's indications, usage and dosage, treatment course etc. in clinical practice. In patients using Shenfu injection, the average age was 62. 15, and patients mainly concentrated in cardiovascular medicine. In clinical practice, Shenfu injection was used mainly for treatment of coronary heart disease (diagnosed as chest obstruction in traditional Chinese medicine). The treatment course mainly ranged from 3 to 7 days, and the dosage was within the limits prescribed by the instruction. Shenfu injection was mainly used for elderly patients, and has been used according to instruction in practice almostly.

  18. Revised fire safety system cuts emergency response time.

    PubMed

    Keir, D C

    1979-03-01

    As Margaret R. Pardee Memorial Hospital, Hendersonville, NC. expanded, fire safety plans had to be reevaluated. With each new addition, fire safety responsibilities for hospital personnel multiplied and overlapped. Confusion resulted, and a revised, simplified, and coordinated fire safety system was devised. Seventeen false alarms within one year, caused by a faulty sprinkler system, gave hospital personnel ample opportunity to test the system and iron out unexpected problems.

  19. Safety and efficacy of intravitreal injection of recombinant erythropoietin for protection of photoreceptor cells in a rat model of retinal detachment

    PubMed Central

    Xie, Z; Chen, F; Wu, X; Zhuang, C; Zhu, J; Wang, J; Ji, H; Wang, Y; Hua, X

    2012-01-01

    Purpose To elucidate the safety and efficacy of exogenous erythropoietin (EPO) for the protection of photoreceptor cells in a rat model of retinal detachment (RD). Methods Recombinant rat EPO (400 ng) was injected into the vitreous cavity of normal rats to observe the eye manifestations. Retinal function was assessed by flash electroretinograms. Histopathological examination of retinal tissue was performed at 14 days and 2 months after injection, respectively. To investigate the inhibitory effect of EPO on photoreceptor cell apoptosis in RD rats, 100, 200, or 400 ng EPO was injected into the vitreous cavity immediately after RD model establishment. Apoptosis of photoreceptor cells was determined at 3 days after injection. Caspase-3 activation was measured by western blot analysis and immunofluorescence, respectively, and the level of Bcl-XL expression was analyzed by western blot. Results Intravitreal injection of EPO 400 ng into normal rats had no significant impact on retinal function, morphology, or structure. Apoptosis of retinal photoreceptor cells apparently increased after RD and was significantly reduced following EPO treatment. The thickness of the outer nuclear layer in the RD+400 ng group was significantly thicker than that in other experimental RD groups both at 14 days and at 2 months after RD (P<0.05). Western blot and immunofluorescence analyses showed decreased caspase-3 activation and increased Bcl-XL expression following EPO treatment. Conclusion Intravitreal injection of EPO 400 ng is safe, and EPO may suppress caspase-3 activation and enhance Bcl-XL expression, resulting in inhibition of apoptosis and protection of photoreceptor cells. PMID:22020175

  20. Gene delivery by direct injection (microinjection) using a controlled-flow system.

    PubMed

    Dean, David A

    2006-12-01

    INTRODUCTIONThis protocol describes a method for constant-flow microinjection using the Pneumatic PicoPump (World Precision Instruments). This type of system is very simple and can be assembled on a relatively low budget. In this method, a constant flow of sample is delivered from the tip of the pipette, and the amount of sample injected into the cell is determined by how long the pipette remains in the cell. A typical system is composed of a pressure regulator that can be adjusted for two pressures (back pressure and injection pressure), a capillary holder, and a coarse and fine micromanipulator.

  1. Striving for safety: communicating and deciding in sociotechnical systems

    PubMed Central

    Flach, John M.; Carroll, John S.; Dainoff, Marvin J.; Hamilton, W. Ian

    2015-01-01

    How do communications and decisions impact the safety of sociotechnical systems? This paper frames this question in the context of a dynamic system of nested sub-systems. Communications are related to the construct of observability (i.e. how components integrate information to assess the state with respect to local and global constraints). Decisions are related to the construct of controllability (i.e. how component sub-systems act to meet local and global safety goals). The safety dynamics of sociotechnical systems are evaluated as a function of the coupling between observability and controllability across multiple closed-loop components. Two very different domains (nuclear power and the limited service food industry) provide examples to illustrate how this framework might be applied. While the dynamical systems framework does not offer simple prescriptions for achieving safety, it does provide guides for exploring specific systems to consider the potential fit between organisational structures and work demands, and for generalising across different systems regarding how safety can be managed. Practitioner Summary: While offering no simple prescriptions about how to achieve safety in sociotechnical systems, this paper develops a theoretical framework based on dynamical systems theory as a practical guide for generalising from basic research to work domains and for generalising across alternative work domains to better understand how patterns of communication and decision-making impact system safety. PMID:25761155

  2. A protocol for the retina surgeon's safe initial intravitreal injections.

    PubMed

    Frenkel, Ronald E P; Haji, Shamim A; La, Melvin; Frenkel, Max P C; Reyes, Angela

    2010-11-10

    To determine the safety of a surgeon's initial consecutive intravitreal injections using a specific protocol and to review the complications that may be attributed to the injection procedure. A retrospective chart review. Fifty-nine patients (30 females, 29 males) received intravitreal injections of pegaptanib, bevacizumab, or ranibizumab as part of their treatment for neovascular age-related macular degeneration. The average patient age was 80 years. Twenty-two patients were diagnosed with or suspected of having glaucoma. Each patient received an average of 5.8 injections. The charts of 59 patients who received a total of 345 intravitreal injections (104 pegaptanib, 74 bevacizumab, 167 ranibizumab) were reviewed. All injections were performed in an office-based setting. Povidone-iodine, topical antibiotics, and eye speculum were used as part of the pre injection procedure. Vision and intraocular pressure were evaluated immediately following each injection. Incidence of post injection complications, including but not limited to endophthalmitis, retinal detachment, traumatic cataract, and vitreous hemorrhage. There were no cases of endophthalmitis, toxic reactions, traumatic cataracts, retinal detachment, or vitreous hemorrhage. There was one case each of lid swelling, transient floaters, retinal pigment epithelial tear, corneal edema, and corneal abrasion. There were five cases of transient no light perception following pegaptanib injections. The incidence of serious complications was very low for the intravitreal injections given. A surgeon's initial intravitreal injections may be performed with a very high degree of safety using this protocol.

  3. Identifying behaviour patterns of construction safety using system archetypes.

    PubMed

    Guo, Brian H W; Yiu, Tak Wing; González, Vicente A

    2015-07-01

    Construction safety management involves complex issues (e.g., different trades, multi-organizational project structure, constantly changing work environment, and transient workforce). Systems thinking is widely considered as an effective approach to understanding and managing the complexity. This paper aims to better understand dynamic complexity of construction safety management by exploring archetypes of construction safety. To achieve this, this paper adopted the ground theory method (GTM) and 22 interviews were conducted with participants in various positions (government safety inspector, client, health and safety manager, safety consultant, safety auditor, and safety researcher). Eight archetypes were emerged from the collected data: (1) safety regulations, (2) incentive programs, (3) procurement and safety, (4) safety management in small businesses (5) production and safety, (6) workers' conflicting goals, (7) blame on workers, and (8) reactive and proactive learning. These archetypes capture the interactions between a wide range of factors within various hierarchical levels and subsystems. As a free-standing tool, they advance the understanding of dynamic complexity of construction safety management and provide systemic insights into dealing with the complexity. They also can facilitate system dynamics modelling of construction safety process. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Post-marketing safety monitoring of shenqifuzheng injection: a solution made of dangshen (Radix Codonopsis) and huangqi (Radix Astragali Mongolici).

    PubMed

    Ai, Qinghua; Zhang, Wen; Xie, Yanming; Huang, Wenhua; Liang, Hong; Cao, Hui

    2014-08-01

    To identify the potential risk factors associated with Shenqifuzheng injection (SFI), a solution made of Dangshen (Radix Codonopsis) and Huangqi (Radix Astragali Mongolici), for the timely provision of information to regulatory authorities. A comprehensive analysis of the production process, quality standards, pharmacology, post-marketing clinical studies, and safety evaluation using the primary literature of adverse reactions (ADR), case analyses, and systematic reviews, intensive hospital safety monitoring of post-marketing drugs, and data provided by the hospital information system (HIS). Sub-acute toxicity tests suggesting that a dose of 15 mL/kg (concentrated solution) had specific biological effects, whereas a smaller dose engendered no observable effects. Long-term toxicity testing in domestic rabbits showed that after SFI was administered for 90 days, the animals in each dosing group showed no chronic toxic reactions. Among 20 100 cases observed, the incidence of an ADR was 1.85 per thousand. From March to November 2013, of the leading institutions and 22 sub-centers involved in the post-marketing clinical safety intensive hospital monitoring, 21 units completed 8484 cases of monitoring, and reported 23 cases of adverse reactions. No damage to renal function was found using SFI at a dosage and a treatment course larger and longer than that recommended for the adjuvant treatment of tumors. This could reduce the mortality rate of admitted patients based on the analysis of the data provided by the HIS. A total of 16 clinical case reports of adverse reactions related to SFI in 1999-2012 were obtained through literature retrieval. These reports contained information concerning 17 cases, with adverse reaction symptoms including thrombocytopenia, rash, chills, feeling cold, palpitation, dyspnea, edema of a lower extremity, palpebral edema, and superficial vein inflammation, among others. This study introduces "get full access" to the flow of information on

  5. Comparison of injection pain caused by the DentalVibe Injection System versus a traditional syringe for inferior alveolar nerve block anaesthesia in paediatric patients.

    PubMed

    Elbay, M; Şermet Elbay, Ü; Yıldırım, S; Uğurluel, C; Kaya, C; Baydemir, C

    2015-06-01

    To compare paediatric patients' pain during needle insertion and injection in inferior alveoler nerve block (IANB) anaesthesia injected by either a traditional syringe (TS) or the DentalVibe Injection Comfort System (DV). the study was a randomised controlled crossover clinical trial, comprised of 60 children aged 6-12 requiring an operative procedure with IANB anaesthesia on their mandibular molars bilaterally. One of the molar teeth was treated with TS and the contralateral tooth was treated with DV. On each visit, subjective and objective pain was evaluated using the Wond-Baker Faces Pain Rating Scale (PRS) and the Face, Legg, Cry, Consolability Scale (FLACC Scale). Patients were asked which anaesthesia technique they preferred. Data were analysed using Wilcoxon signed rank, Spearman correlation, and Mann-Whitney U tests. There were no statistically significant differences for pain evalution during needle insertion and injection of each injection system. However, a negative correlation was found on the FLACC between age and pain scores during injection after using DV. Paediatric patients experienced similar pain during IANB anaesthesia administered with TS and DV. With increased age, pain values reduced during anaesthetic agent injection with DV according to FLACC. The traditional procedure was preferred to DV in paediatric patients.

  6. Assessment of the efficacy and safety of single platelet-rich plasma injection on different types and grades of facial wrinkles.

    PubMed

    Elnehrawy, Naema Y; Ibrahim, Zeinab A; Eltoukhy, Azza M; Nagy, Hala M

    2017-03-01

    Platelet-rich plasma (PRP) is considered as a growing modality for tissue regeneration and a developing research area for clinicians and researchers. PRP injection treatment provides supraphysiological concentrations of growth factors that may help in accelerated tissue remodeling and regeneration. To evaluate the efficacy and safety of single autologous PRP intradermal injection for treatment of facial wrinkles and for facial rejuvenation. A total of 20 subjects with different types of facial wrinkles were included in this study. All subjects received single PRP intradermal injection and were clinically assessed before and after treatment for a period of 8 weeks using Wrinkle Severity Rating Scale (WSRS), Skin Homogeneity and Texture (SHnT) Scale, Physician Assessment Scale, and Subject Satisfaction Scale. The mean value of WSRS reduced from 2.90 ± 0.91 before treatment to 2.10 ± 0.79 after 8 weeks of treatment. The most significant results were with younger subjects that have mild and moderate wrinkles of the nasolabial folds (NLFs). Fourteen of seventeen subjects with NLFs showed more than 25% improvement in their appearance. Side effects of PRP treatment were minimal to mild and with excellent tolerability. Single PRP intradermal injection is well tolerated and capable of rejuvenating the face and producing a significant correction of wrinkles especially the NLFs. © 2016 Wiley Periodicals, Inc.

  7. ESIS ions injection, holding and extraction control system

    NASA Astrophysics Data System (ADS)

    Donets, E. D.; Donets, E. E.; Donets, D. E.; Lyuosev, D. A.; Ponkin, D. O.; Ramsdorf, A. Yu.; Boytsov, A. Yu.; Salnikov, V. V.; Shirikov, I. V.

    2018-04-01

    Electron string ion source (ESIS) KRION-6T is one of the main parts of the NICA injection complex [1]. During the work on creation of a new ion source for the NICA/MPD project the new ion motion control system was developed, produced and successfully put into operation. Modules development process and operation results are described.

  8. Flow monitoring and control system for injection wells

    DOEpatents

    Corey, J.C.

    1991-01-01

    The present invention relates to a system for monitoring and controlling the rate of fluid flow from an injection well used for in-situ remediation of contaminated groundwater. The United States Government has rights in this invention pursuant to Contract No. DE-AC09-89SR18035 between the US Department of Energy and Westinghouse Savannah River Company.

  9. Embedded computer controlled premixing inline injection system for air-assisted variable-rate sprayers

    USDA-ARS?s Scientific Manuscript database

    Improvements to reduce chemical waste and environmental pollution for variable-rate sprayers used in orchards and ornamental nurseries require inline injection techniques. A microprocessor controlled premixing inline injection system implementing a ceramic piston chemical metering pump and two small...

  10. Uncovering high rates of unsafe injection equipment reuse in rural Cameroon: validation of a survey instrument that probes for specific misconceptions

    PubMed Central

    2011-01-01

    Background Unsafe reuse of injection equipment in hospitals is an on-going threat to patient safety in many parts of Africa. The extent of this problem is difficult to measure. Standard WHO injection safety assessment protocols used in the 2003 national injection safety assessment in Cameroon are problematic because health workers often behave differently under the observation of visitors. The main objective of this study is to assess the extent of unsafe injection equipment reuse and potential for blood-borne virus transmission in Cameroon. This can be done by probing for misconceptions about injection safety that explain reuse without sterilization. These misconceptions concern useless precautions against cross-contamination, i.e. "indirect reuse" of injection equipment. To investigate whether a shortage of supply explains unsafe reuse, we compared our survey data against records of purchases. Methods All health workers at public hospitals in two health districts in the Northwest Province of Cameroon were interviewed about their own injection practices. Injection equipment supply purchase records documented for January to December 2009 were compared with self-reported rates of syringe reuse. The number of HIV, HBV and HCV infections that result from unsafe medical injections in these health districts is estimated from the frequency of unsafe reuse, the number of injections performed, the probability that reused injection equipment had just been used on an infected patient, the size of the susceptible population, and the transmission efficiency of each virus in an injection. Results Injection equipment reuse occurs commonly in the Northwest Province of Cameroon, practiced by 44% of health workers at public hospitals. Self-reported rates of syringe reuse only partly explained by records on injection equipment supplied to these hospitals, showing a shortage of syringes where syringes are reused. Injection safety interventions could prevent an estimated 14-336 HIV

  11. Safety Management Systems.

    ERIC Educational Resources Information Center

    Fido, A. T.; Wood, D. O.

    This document discusses the issues that need to be considered by the education and training system as it responds to the changing needs of industry in Great Britain. Following a general introduction, the development of quality management ideas is traced. The underlying principles of safety and risk management are clarified and the implications of…

  12. 46 CFR 62.25-15 - Safety control systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Safety control systems. 62.25-15 Section 62.25-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING VITAL SYSTEM AUTOMATION General Requirements for All Automated Vital Systems § 62.25-15 Safety control systems. (a...

  13. Physical Watermarking for Securing Cyber-Physical Systems via Packet Drop Injections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ozel, Omur; Weekrakkody, Sean; Sinopoli, Bruno

    Physical watermarking is a well known solution for detecting integrity attacks on Cyber-Physical Systems (CPSs) such as the smart grid. Here, a random control input is injected into the system in order to authenticate physical dynamics and sensors which may have been corrupted by adversaries. Packet drops may naturally occur in a CPS due to network imperfections. To our knowledge, previous work has not considered the role of packet drops in detecting integrity attacks. In this paper, we investigate the merit of injecting Bernoulli packet drops into the control inputs sent to actuators as a new physical watermarking scheme. Withmore » the classical linear quadratic objective function and an independent and identically distributed packet drop injection sequence, we study the effect of packet drops on meeting security and control objectives. Our results indicate that the packet drops could act as a potential physical watermark for attack detection in CPSs.« less

  14. 33 CFR 96.220 - What makes up a safety management system?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.220 What makes up a safety management system? (a) The safety management system must document the responsible person's— (1) Safety and pollution prevention...

  15. Manufacturing injection-moleded Fresnel lens parquets for point-focus concentrating photovoltaic systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, E.M.; Masso, J.D.

    This project involved the manufacturing of curved-faceted, injection-molded, four-element Fresnel lens parquets for concentrating photovoltaic arrays. Previous efforts showed that high-efficiency (greater than 82%) Fresnel concentrators could be injection molded. This report encompasses the mold design, molding, and physical testing of a four-lens parquet for a solar photovoltaic concentrator system.

  16. Injection practices in a metropolis of North India: perceptions, determinants and issues of safety.

    PubMed

    Kotwal, A; Priya, R; Thakur, R; Gupta, V; Kotwal, J; Seth, T

    2004-08-01

    At least 50 percent of the injections administered each year are unsafe, more particularly in developing countries, posing serious health risks. An initial assessment to describe injection practices; their determinants and adverse effects can prevent injection-associated transmission of blood borne pathogens by reducing injection frequency and adoption of safe injection practices. To assess the injection practices in a large metropolitan city encompassing varied socio-cultural scenarios. STUDY SETTING AND DESIGN: Field based cross sectional survey covering urban non-slum, slum and peri-urban areas of a large metropolitan city. Injection prescribers, providers and community members selected by random sampling from the study areas. Pre tested questionnaires assessed knowledge and perceptions of study subjects towards injections and their possible complications. Observation of the process of injection and prescription audit also carried out. MS Access for database and SPSS ver 11 for analysis. Point estimates, 95% confidence intervals, Chi Square, t test, one-way ANOVA. The per capita injection rate was 5.1 per year and ratio of therapeutic to immunization injections was 4.4:1. Only 22.5%of injections were administered with a sterile syringe and needle. The level of knowledge about HIV and HBV transmission by unsafe injections was satisfactory amongst prescribers and community, but inadequate amongst providers. HCV was known to a very few in all the groups. The annual incidence of needle stick injuries among providers was quite high. A locally relevant safe injection policy based on multi disciplinary approach is required to reduce number of injections, unsafe injections and their attendant complications.

  17. The efficacy and safety of intramuscular injections of methylcobalamin in patients with chronic nonspecific low back pain: a randomised controlled trial.

    PubMed

    Chiu, C K; Low, T H; Tey, Y S; Singh, V A; Shong, H K

    2011-12-01

    Chronic, nonspecific low back pain is a difficult ailment to treat and poses an economic burden in terms of medical expenses and productivity loss. The aim of this study was to determine the efficacy and safety of intramuscular metylcobalamin in the treatment of chronic nonspecific low back pain. This was a double-blinded, randomised, controlled experimental study. 60 patients were assigned to either the methylcobalamin group or the placebo group. The former received intramuscular injections of 500 mcg parenteral methylcobalamin in 1 ml solution three times a week for two weeks, and the placebo group received 1 ml normal saline. Patients were assessed with Oswestry Disability Index questionnaire Version 2.0 and Visual Analogue Scale pain score. They were scored before commencement of the injections and at two months interval. Of the 60 patients, 27 received the placebo injections and 33 were given methylcobalamin injections. A total of 58 patients were available for review at two months (placebo: n is 26; methylcobalamin: n is 32). There was a significant improvement in the Oswestry Disability Index and Visual Analogue Scale pain scores in the methylcobalamin group as compared with the placebo group (p-value less than 0.05). Only minor adverse reactions such as pain and haematoma at the injection sites were reported by some patients. Intramuscular methylcobalamin is both an effective and safe method of treatment for patients with nonspecific low back pain, both singly or in combination with other forms of treatment.

  18. Analysis of Aviation Safety Reporting System Incident Data Associated With the Technical Challenges of the Vehicle Systems Safety Technology Project

    NASA Technical Reports Server (NTRS)

    Withrow, Colleen A.; Reveley, Mary S.

    2014-01-01

    This analysis was conducted to support the Vehicle Systems Safety Technology (VSST) Project of the Aviation Safety Program (AVsP) milestone VSST4.2.1.01, "Identification of VSST-Related Trends." In particular, this is a review of incident data from the NASA Aviation Safety Reporting System (ASRS). The following three VSST-related technical challenges (TCs) were the focus of the incidents searched in the ASRS database: (1) Vechicle health assurance, (2) Effective crew-system interactions and decisions in all conditions; and (3) Aircraft loss of control prevention, mitigation, and recovery.

  19. Injection practices in Nepal: health policymakers’ perceptions

    PubMed Central

    2014-01-01

    Background The unnecessary and unsafe use of injections is common in developing countries like Nepal. Policymakers have an important role in promoting rational and safe injection use. Hence, the present study was carried out to explore the perception of health policymakers regarding safe injection practice in Nepal. Methods An exploratory qualitative study design was used in this study. Key policymakers from both the central and regional level were selected using purposive sampling. A semi-structured questionnaire advocated by the World Health Organization (WHO) was used after modifying the context. Interviews were conducted to clarify doubts and obtain additional information. The data was analyzed manually using deductive content analysis technique. Results In total, eleven policymakers participated. All unanimously agreed that injection safety is a problem and seven participants reported that injections are overused. They shared the opinion that injections are administered by various providers, including formal and informal health providers, and also quacks. Almost half the respondents reported that the National Drug Policy discourages injection overuse, while others reported that the policy contains no provisions regarding injection overuse. Most policymakers stated that only single-use disposable injection equipment is used to provide injection, while others thought that sterilizable glass syringe is also used. More than half of the participants believed that the quality of injection equipment available in the Nepalese market is not regulated by any government institution. Almost two-third of the policymakers stated that syringes and needles are not reused, while the rest thought syringes might be reused without sterilization in some parts of the country. Almost half of the respondents stated that illegal commercialization of used syringes exists in Nepal. Almost all respondents thought that health care institutions have a waste management plan, while more than

  20. Injection practices in Nepal: health policymakers' perceptions.

    PubMed

    Gyawali, Sudesh; Rathore, Devendra Singh; Shankar, Pathiyil Ravi; Maskey, Manisha; Vikash, Kumar K C

    2014-06-24

    The unnecessary and unsafe use of injections is common in developing countries like Nepal. Policymakers have an important role in promoting rational and safe injection use. Hence, the present study was carried out to explore the perception of health policymakers regarding safe injection practice in Nepal. An exploratory qualitative study design was used in this study. Key policymakers from both the central and regional level were selected using purposive sampling. A semi-structured questionnaire advocated by the World Health Organization (WHO) was used after modifying the context. Interviews were conducted to clarify doubts and obtain additional information. The data was analyzed manually using deductive content analysis technique. In total, eleven policymakers participated. All unanimously agreed that injection safety is a problem and seven participants reported that injections are overused. They shared the opinion that injections are administered by various providers, including formal and informal health providers, and also quacks. Almost half the respondents reported that the National Drug Policy discourages injection overuse, while others reported that the policy contains no provisions regarding injection overuse. Most policymakers stated that only single-use disposable injection equipment is used to provide injection, while others thought that sterilizable glass syringe is also used. More than half of the participants believed that the quality of injection equipment available in the Nepalese market is not regulated by any government institution. Almost two-third of the policymakers stated that syringes and needles are not reused, while the rest thought syringes might be reused without sterilization in some parts of the country. Almost half of the respondents stated that illegal commercialization of used syringes exists in Nepal. Almost all respondents thought that health care institutions have a waste management plan, while more than half of them opined that

  1. Autonomous Flight Safety System - Phase III

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Autonomous Flight Safety System (AFSS) is a joint KSC and Wallops Flight Facility project that uses tracking and attitude data from onboard Global Positioning System (GPS) and inertial measurement unit (IMU) sensors and configurable rule-based algorithms to make flight termination decisions. AFSS objectives are to increase launch capabilities by permitting launches from locations without range safety infrastructure, reduce costs by eliminating some downrange tracking and communication assets, and reduce the reaction time for flight termination decisions.

  2. Ice Reduces Needle-Stick Pain Associated With Local Anesthetic Injection

    PubMed Central

    Mahshidfar, Babak; Cheraghi Shevi, Salimeh; Abbasi, Mohsen; Kasnavieh, Mohammad Hosseini; Rezai, Mahdi; Zavereh, Mina; Mosaddegh, Reza

    2016-01-01

    Background Local anesthetic injections are widely used in the emergency department for different purposes. Pain management for such injections is of great importance to both patients and the healthcare system. Objectives Our study aimed to determine the effectiveness and safety of cryotherapy in patients receiving local anesthetic injections. Methods Subjects who presented with superficial lacerations were randomly assigned to 2 groups, the first group received ice packing prior to injection and the second did not. The pain severity, length and depth of the laceration, and the other necessary information before and after the pain-reducing intervention were measured, documented, and compared at the end of the study. Pain scores were measured using a numerical rating scale before and after the procedure, and the differences were compared using a t-test. Results Ninety subjects were enrolled in the study, 45 in each group. There were no statistical differences between the 2 groups in terms of baseline preoperative and operative characteristics (P > 0.05). The pain scores in the cryotherapy group were significantly lower before and after the procedure (P < 0.001). There was no statistically significant difference between the 2 groups for wound infection (P = 0.783). Conclusions Cooling the injection site prior to local anesthetic injection is an effective and inexpensive method to reduce the pain and discomfort caused by the injection. PMID:27847696

  3. Efficacy and safety of newly developed cross-linked dextran gel injection for glans penis augmentation with a novel technique

    PubMed Central

    Yang, Dae Yul; Ko, Kyungtae; Lee, Seong Ho; Moon, Du Geon; Kim, Jong Wook; Lee, Won Ki

    2018-01-01

    There is no safe and effective standard method for glans penis augmentation. Furthermore, there has been scant research on glans penis augmentation due to a poor understanding of glans anatomy, technical difficulty, and a lack of suitable substances for augmentation. Cross-linked dextran gel is a newly developed filler for soft-tissue augmentation. We evaluated the efficacy and safety of using a novel technique to inject cross-linked dextran gel for glans penis augmentation during a 24-week follow-up study. This prospective, single-arm, multicenter study enrolled twenty healthy adult men who underwent glans penis augmentation between June and August 2013. Cross-linked dextran gel was injected into the glans penis using a simple and easy technique. The sizes of the glans penis and individual satisfaction were assessed. Any adverse event was also reported. A total of 18 individuals were analyzed; two of them were lost to follow-up. The mean procedure time and injected volume were about 30 min and 6.6 ± 0.9 ml, respectively. The mean surface areas of the glans at baseline and 24 weeks were 20.0 ± 3.5 cm2 and 33.6 ± 5.4 cm2, respectively, representing a mean increase of 68.7% ± 14.0% (P < 0.001). Sixteen individuals (88.9%) were satisfied with the outcomes, and none were dissatisfied. There were no serious adverse events during the study. Cross-linked dextran gel injection for glans penis augmentation was easy and showed a significant augmentative effect on the glans penis, good durability, and was well tolerated without serious adverse events. Therefore, cross-linked dextran gel injection may be an effective, new technique for glans penis augmentation. PMID:28303807

  4. The Determination of Several Spray Characteristics of a High-Speed Oil Engine Injection System with an Oscilloscope

    NASA Technical Reports Server (NTRS)

    Hicks, Chester W; Moore, Charles S

    1928-01-01

    An investigation was conducted to determine the injection lag, duration of injection, and spray start and cut-off characteristics of a fuel injection system operated on an engine and injecting fuel into the atmosphere.

  5. Does intrauterine injection of low-molecular-weight heparin improve the clinical pregnancy rate in intracytoplasmic sperm injection?

    PubMed Central

    El-Faissal, Yahia; Aboulghar, Mona; Mansour, Ragaa; Serour, Gamal I; Aboulghar, Mohamed

    2016-01-01

    Objective Heparin can modulate proteins, and influence processes involved in implantation and trophoblastic development. This study aimed to assess the improvement of clinical pregnancy and implantation rates after local intrauterine injection of low-molecular-weight heparin (LMWH) in patients undergoing intracytoplasmic sperm injection (ICSI). Methods A randomised case/control design was followed in women scheduled for ICSI. The study arm was injected with intrauterine LMWH during mock embryo transfer immediately following the ovum pickup procedure, while the control arm was given an intrauterine injection with a similar volume of tissue culture media. Side effects, the clinical pregnancy rate, and the implantation rate were recorded. Results The pregnancy rate was acceptable (33.9%) in the LMWH arm with no significant reported side effects, confirming the safety of the intervention. No statistically significant differences were found in the clinical pregnancy and implantation rates between both groups (p=0.182 and p=0.096, respectively). The odds ratio of being pregnant after intrauterine injection with LMWH compared to the control group was 0.572 (95% confidence interval [CI], 0.27−1.22), while the risk ratio was 0.717 (95% CI, 0.46−1.13; p=0.146). No statistical significance was found between the two groups in other factors affecting implantation, such as day of transfer (p=0.726), number of embryos transferred (p=0.362), or embryo quality. Conclusion Intrauterine injection of LMWH is a safe intervention, but the dose used in this study failed to improve the outcome of ICSI. Based on its safety, further research involving modification of the dosage and/or the timing of administration could result in improved ICSI success rates. PMID:28090465

  6. Preliminary evaluation of the Highland Rim aquifer system in Tennessee for receiving injected wastes

    USGS Publications Warehouse

    Bradley, M.W.

    1986-01-01

    The EPA has authority under the Safe Drinking Water Act to protect underground sources of drinking water from contamination by deep well injection. An aquifer, however, may be exempted from protection and used for injected wastes where the aquifer meets criteria established in the Agency 's Underground Injection Control program. The Highland Rim aquifer system in Tennessee consists of Mississippian age carbonate rocks and occurs from the Valley and Ridge of East Tennessee to west of the Tennessee River. This aquifer contains potable water and is an important source of drinking water for municipal and domestic supplies on the Highland Rim. The Highland Rim aquifer system under parts of the Cumberland Plateau is not currently used as a source of drinking water and is not expected to be used in the future. These areas meet parts of the EPA 's Underground Injection Control criteria for exempting aquifers to receive injected waste. (Author 's abstract)

  7. Doxycycline Injection

    MedlinePlus

    Doxycycline injection is used to treat or prevent bacterial infections, including pneumonia and other respiratory tract infections. ... certain skin, genital, intestine, and urinary system infections. Doxycycline injection may be used to treat or prevent ...

  8. System safety in Stirling engine development

    NASA Technical Reports Server (NTRS)

    Bankaitis, H.

    1981-01-01

    The DOE/NASA Stirling Engine Project Office has required that contractors make safety considerations an integral part of all phases of the Stirling engine development program. As an integral part of each engine design subtask, analyses are evolved to determine possible modes of failure. The accepted system safety analysis techniques (Fault Tree, FMEA, Hazards Analysis, etc.) are applied in various degrees of extent at the system, subsystem and component levels. The primary objectives are to identify critical failure areas, to enable removal of susceptibility to such failures or their effects from the system and to minimize risk.

  9. Fuel injection and mixing systems having piezoelectric elements and methods of using the same

    DOEpatents

    Mao, Chien-Pei [Clive, IA; Short, John [Norwalk, IA; Klemm, Jim [Des Moines, IA; Abbott, Royce [Des Moines, IA; Overman, Nick [West Des Moines, IA; Pack, Spencer [Urbandale, IA; Winebrenner, Audra [Des Moines, IA

    2011-12-13

    A fuel injection and mixing system is provided that is suitable for use with various types of fuel reformers. Preferably, the system includes a piezoelectric injector for delivering atomized fuel, a gas swirler, such as a steam swirler and/or an air swirler, a mixing chamber and a flow mixing device. The system utilizes ultrasonic vibrations to achieve fuel atomization. The fuel injection and mixing system can be used with a variety of fuel reformers and fuel cells, such as SOFC fuel cells.

  10. Safer injections following a new national medicine policy in the public sector, Burkina Faso 1995 – 2000

    PubMed Central

    Logez, Sophie; Hutin, Yvan; Somda, Paul; Thuault, Jérôme; Holloway, Kathleen

    2005-01-01

    Background The common failure of health systems to ensure adequate and sufficient supplies of injection devices may have a negative impact on injection safety. We conducted an assessment in April 2001 to determine to which extent an increase in safe injection practices between 1995 and 2000 was related to the increased access to injection devices because of a new essential medicine policy in Burkina Faso. Methods We reviewed outcomes of the new medicine policy implemented in1995. In April 2001, a retrospective programme review assessed the situation between 1995 and 2000. We visited 52 health care facilities where injections had been observed during a 2000 injection safety assessment and their adjacent operational public pharmaceutical depots. Data collection included structured observations of available injection devices and an estimation of the proportion of prescriptions including at least one injection. We interviewed wholesaler managers at national and regional levels on supply of injection devices to public health facilities. Results Fifty of 52 (96%) health care facilities were equipped with a pharmaceutical depot selling syringes and needles, 37 (74%) of which had been established between 1995 and 2000. Of 50 pharmaceutical depots, 96% had single-use 5 ml syringes available. At all facilities, patients were buying syringes and needles out of the depot for their injections prescribed at the dispensary. While injection devices were available in greater quantities, the proportion of prescriptions including at least one injection remained stable between 1995 (26.5 %) and 2000 (23.8 %). Conclusion The implementation of pharmaceutical depots next to public health care facilities increased geographical access to essential medicines and basic supplies, among which syringes and needles, contributing substantially to safer injection practices in the absence of increased use of therapeutic injections. PMID:16364178

  11. [Experiences with power-injectable port systems: complications, patient satisfaction and clinical benefit].

    PubMed

    Chang, D-H; Kabbasch, C; Bovenschulte, H; Libicher, M; Maintz, D; Bangard, C

    2013-05-01

    Evaluation of complications, patient satisfaction and clinical benefit of port systems with authorization for high pressure injection of contrast agent during CT/MR examinations. Ultrasound-guided insertions of central venous port catheters were performed through the lateral subclavian vein at a university teaching hospital. The radiological information system (HIS/RIS) was used to evaluate technical success and complication rates. Assessment of patient satisfaction and clinical benefit was carried out by a questionnaire during a telephone call 6 months after implantation of the port system. A total of 195 port systems in 193 patients were implanted. The catheter remained in place for a mean duration of 169 days (overall 29,210 catheter days). The technical success rate was 99.5 % and the overall complication rate was 17.4 % (24/138; 0.82 per 1000 catheter days). Follow-up revealed 13 early port explantations (9 %). Most of the patients reported high satisfaction in general (satisfied/very satisfied: 94 %). 34/209 contrast-enhanced CT/MRT scans (16 %) were performed using the port for contrast media injection. There were no complications during or after administration of contrast agent via the port system. The Powerport system is a safe alternative for peripheral i. v. contrast media injection during CT/MR scans, but has been infrequently used. Most patients reported high overall satisfaction with the port system. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Fire safety evaluation system for NASA office/laboratory buildings

    NASA Astrophysics Data System (ADS)

    Nelson, H. E.

    1986-11-01

    A fire safety evaluation system for office/laboratory buildings is developed. The system is a life safety grading system. The system scores building construction, hazardous areas, vertical openings, sprinklers, detectors, alarms, interior finish, smoke control, exit systems, compartmentation, and emergency preparedness.

  13. A comprehensive situation assessment of injection practices in primary health care hospitals in Bangladesh

    PubMed Central

    2011-01-01

    Background Understanding injection practices is crucial for evidence-based development of intervention initiatives. This study explored the extent of injection use and injection safety practices in primary care hospitals in Bangladesh. Methods The study employed both quantitative and qualitative research methods. The methods used were - a retrospective audit of prescriptions (n = 4320), focus group discussions (six with 43 participants), in-depth interviews (n = 38) with a range service providers, and systematic observation of the activities of injection providers (n = 120), waste handlers (n = 48) and hospital facilities (n = 24). Quantitative and qualitative data were assessed with statistical and thematic analysis, respectively, and then combined. Results As many as 78% of our study sample (n = 4230) received an injection. The most commonly prescribed injections (n = 3354) including antibiotics (78.3%), IV fluids (38.6%), analgesics/pain killers (29.4%), vitamins (26.7%), and anti-histamines (18.5%). Further, 43.7% (n = 1145) of the prescribed antibiotics (n = 2626) were given to treat diarrhea and 42.3% (n = 600) of IV fluids (n = 1295) were used to manage general weakness conditions. Nearly one-third (29.8%; n = 36/120) of injection providers reported needle-stick injuries in the last 6 months with highest incidences in Rajshahi division followed by Dhaka division. Disposal of injection needles, syringes and other materials was not done properly in 83.5% (n = 20/24) of the facilities. Health providers' safety concerns were not addressed properly; only 23% (n = 28/120) of the health providers and 4.2% (n = 2/48) of the waste handlers were fully immunized against Hepatitis B virus. Moreover, 73% (n = 87/120) of the injection providers and 90% (n = 43/48) of the waste handlers were not trained in injection safety practices and infection prevention. Qualitative data further confirmed that both providers and patients preferred injections, believing that they

  14. Design process of the nanofluid injection mechanism in nuclear power plants

    NASA Astrophysics Data System (ADS)

    Kang, Myoung-Suk; Jee, Changhyun; Park, Sangjun; Bang, In Choel; Heo, Gyunyoung

    2011-04-01

    Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs). This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs) assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD) in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner.

  15. Design process of the nanofluid injection mechanism in nuclear power plants

    PubMed Central

    2011-01-01

    Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs). This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs) assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD) in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner. PMID:21711896

  16. Design process of the nanofluid injection mechanism in nuclear power plants.

    PubMed

    Kang, Myoung-Suk; Jee, Changhyun; Park, Sangjun; Bang, In Choel; Heo, Gyunyoung

    2011-04-27

    Nanofluids, which are engineered suspensions of nanoparticles in a solvent such as water, have been found to show enhanced coolant properties such as higher critical heat flux and surface wettability at modest concentrations, which is a useful characteristic in nuclear power plants (NPPs). This study attempted to provide an example of engineering applications in NPPs using nanofluid technology. From these motivations, the conceptual designs of the emergency core cooling systems (ECCSs) assisted by nanofluid injection mechanism were proposed after following a design framework to develop complex engineering systems. We focused on the analysis of functional requirements for integrating the conventional ECCSs and nanofluid injection mechanism without loss of performance and reliability. Three candidates of nanofluid-engineered ECCS proposed in previous researches were investigated by applying axiomatic design (AD) in the manner of reverse engineering and it enabled to identify the compatibility of functional requirements and potential design vulnerabilities. The methods to enhance such vulnerabilities were referred from TRIZ and concretized for the ECCS of the Korean nuclear power plant. The results show a method to decouple the ECCS designs with the installation of a separate nanofluids injection tank adjacent to the safety injection tanks such that a low pH environment for nanofluids can be maintained at atmospheric pressure which is favorable for their injection in passive manner.

  17. Overview of Energy Systems' safety analysis report programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1992-03-01

    The primary purpose of an Safety Analysis Report (SAR) is to provide a basis for judging the adequacy of a facility's safety. The SAR documents the safety analyses that systematically identify the hazards posed by the facility, analyze the consequences and risk of potential accidents, and describe hazard control measures that protect the health and safety of the public and employees. In addition, some SARs document, as Technical Safety Requirements (TSRs, which include Technical Specifications and Operational Safety Requirements), technical and administrative requirements that ensure the facility is operated within prescribed safety limits. SARs also provide conveniently summarized information thatmore » may be used to support procedure development, training, inspections, and other activities necessary to facility operation. This Overview of Energy Systems Safety Analysis Report Programs'' Provides an introduction to the programs and processes used in the development and maintenance of the SARs. It also summarizes some of the uses of the SARs within Energy Systems and DOE.« less

  18. Simple flow injection colorimetric system for determination of paraquat in natural water.

    PubMed

    Chuntib, Prakit; Jakmunee, Jaroon

    2015-11-01

    A simple and low cost flow injection colorimetric system has been developed for determination of paraquat in natural water. The developed method is based on the reduction of paraquat by using sodium dithionite as a reducing agent in an alkaline medium to produce a blue free radical ion that can be detected by a simple light emitting diode-light dependent resistor (LED-LDR) colorimeter. The standard or sample solution was injected via a set of 3-way solenoid valves into a water carrier stream and flowed to merge with reagent to generate a colored product which is proportional to the concentration of paraquat ion in the solution. Under the optimum condition of the system, i.e., mixing coil length 30 cm, flow rate 2.0 mL min(-1), sample volume 100 μL, concentrations of dithionite 0.1% (w/v) and sodium hydroxide 0.06 mol L(-1), a linear calibration graph in the range of 0.2-10.0 mg L(-1) with a correlation coefficient of 0.9996, and a limit of detection of 0.15 mg L(-1) were achieved. Relative standard deviation for 9 replicate injections of 1 mg L(-1) paraquat is 3.7%. A sample throughput of 40 injections h(-1) was achieved. The limit of detection can be improved by off-line preconcentration of paraquat employing a column packed with Dowex 50WX8-100 (H) cation exchange resin and eluted with 10% (w/v) ammonium chloride in ammonium buffer solution pH 10. The eluting solution was then injected into the FI system for paraquat determination. The proposed system did not suffer from interferences of some possible ions in natural water and other herbicides. Recoveries obtained by spiking 0.5 and 5.0 mg L(-1) paraquat standard into water samples were in the range of 104-110% and 101-105%, respectively. The developed system can be conveniently applied for screening of paraquat contaminated in natural water. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Critical Characteristics of Radiation Detection System Components to be Dedicated for use in Safety Class and Safety Significant System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DAVIS, S.J.

    2000-12-28

    This document identifies critical characteristics of components to be dedicated for use in Safety Significant (SS) Systems, Structures, or Components (SSCs). This document identifies the requirements for the components of the common, radiation area, monitor alarm in the WESF pool cell. These are procured as Commercial Grade Items (CGI), with the qualification testing and formal dedication to be performed at the Waste Encapsulation Storage Facility (WESF) for use in safety significant systems. System modifications are to be performed in accordance with the approved design. Components for this change are commercially available and interchangeable with the existing alarm configuration This documentmore » focuses on the operational requirements for alarm, declaration of the safety classification, identification of critical characteristics, and interpretation of requirements for procurement. Critical characteristics are identified herein and must be verified, followed by formal dedication, prior to the components being used in safety related applications.« less

  20. Urine Pretreat Injection System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    A new method of introducing the OXONE (Registered Trademark) Monopersulfate Compound for urine pretreat into a two-phase urine/air flow stream has been successfully tested and evaluated. The feasibility of this innovative method has been established for purposes of providing a simple, convenient, and safe method of handling a chemical pretreat required for urine processing in a microgravity space environment. Also, the Oxone portion of the urine pretreat has demonstrated the following advantages during real time collection of 750 pounds of urine in a Space Station design two-phase urine Fan/Separator: Eliminated urine precipitate buildup on internal hardware and plumbing; Minimized odor from collected urine; and Virtually eliminated airborne bacteria. The urine pretreat, as presently defined for the Space Station program for proper downstream processing of urine, is a two-part chemical treatment of 5.0 grams of Oxone and 2.3 ml of H2SO4 per liter of urine. This study program and test demonstrated only the addition of the proper ratio of Oxone into the urine collection system upstream of the Fan/Separator. This program was divided into the following three major tasks: (1) A trade study, to define and recommend the type of Oxone injection method to pursue further; (2) The design and fabrication of the selected method; and (3) A test program using high fidelity hardware and fresh urine to demonstrate the method feasibility. The trade study was conducted which included defining several methods for injecting Oxone in different forms into a urine system. Oxone was considered in a liquid, solid, paste and powered form. The trade study and the resulting recommendation were presented at a trade study review held at Hamilton Standard on 24-25 October 94. An agreement was reached at the meeting to continue the solid tablet in a bag concept which included a series of tablets suspended in the urine/air flow stream. These Oxone tablets would slowly dissolve at a controlled rate

  1. System Study: High-Pressure Coolant Injection 1998-2014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schroeder, John Alton

    2015-12-01

    This report presents an unreliability evaluation of the high-pressure coolant injection system (HPCI) at 25 U.S. commercial boiling water reactors. Demand, run hours, and failure data from fiscal year 1998 through 2014 for selected components were obtained from the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The unreliability results are trended for the most recent 10 year period, while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

  2. Overview of Risk Mitigation for Safety-Critical Computer-Based Systems

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo

    2015-01-01

    This report presents a high-level overview of a general strategy to mitigate the risks from threats to safety-critical computer-based systems. In this context, a safety threat is a process or phenomenon that can cause operational safety hazards in the form of computational system failures. This report is intended to provide insight into the safety-risk mitigation problem and the characteristics of potential solutions. The limitations of the general risk mitigation strategy are discussed and some options to overcome these limitations are provided. This work is part of an ongoing effort to enable well-founded assurance of safety-related properties of complex safety-critical computer-based aircraft systems by developing an effective capability to model and reason about the safety implications of system requirements and design.

  3. Autonomous system for launch vehicle range safety

    NASA Astrophysics Data System (ADS)

    Ferrell, Bob; Haley, Sam

    2001-02-01

    The Autonomous Flight Safety System (AFSS) is a launch vehicle subsystem whose ultimate goal is an autonomous capability to assure range safety (people and valuable resources), flight personnel safety, flight assets safety (recovery of valuable vehicles and cargo), and global coverage with a dramatic simplification of range infrastructure. The AFSS is capable of determining current vehicle position and predicting the impact point with respect to flight restriction zones. Additionally, it is able to discern whether or not the launch vehicle is an immediate threat to public safety, and initiate the appropriate range safety response. These features provide for a dramatic cost reduction in range operations and improved reliability of mission success. .

  4. 33 CFR 147.847 - Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Safety Zone; BW PIONEER Floating... ZONES § 147.847 Safety Zone; BW PIONEER Floating Production, Storage, and Offloading System Safety Zone. (a) Description. The BW PIONEER, a Floating Production, Storage and Offloading (FPSO) system, is in...

  5. Demonstration of a Safety Analysis on a Complex System

    NASA Technical Reports Server (NTRS)

    Leveson, Nancy; Alfaro, Liliana; Alvarado, Christine; Brown, Molly; Hunt, Earl B.; Jaffe, Matt; Joslyn, Susan; Pinnell, Denise; Reese, Jon; Samarziya, Jeffrey; hide

    1997-01-01

    For the past 17 years, Professor Leveson and her graduate students have been developing a theoretical foundation for safety in complex systems and building a methodology upon that foundation. The methodology includes special management structures and procedures, system hazard analyses, software hazard analysis, requirements modeling and analysis for completeness and safety, special software design techniques including the design of human-machine interaction, verification, operational feedback, and change analysis. The Safeware methodology is based on system safety techniques that are extended to deal with software and human error. Automation is used to enhance our ability to cope with complex systems. Identification, classification, and evaluation of hazards is done using modeling and analysis. To be effective, the models and analysis tools must consider the hardware, software, and human components in these systems. They also need to include a variety of analysis techniques and orthogonal approaches: There exists no single safety analysis or evaluation technique that can handle all aspects of complex systems. Applying only one or two may make us feel satisfied, but will produce limited results. We report here on a demonstration, performed as part of a contract with NASA Langley Research Center, of the Safeware methodology on the Center-TRACON Automation System (CTAS) portion of the air traffic control (ATC) system and procedures currently employed at the Dallas/Fort Worth (DFW) TRACON (Terminal Radar Approach CONtrol). CTAS is an automated system to assist controllers in handling arrival traffic in the DFW area. Safety is a system property, not a component property, so our safety analysis considers the entire system and not simply the automated components. Because safety analysis of a complex system is an interdisciplinary effort, our team included system engineers, software engineers, human factors experts, and cognitive psychologists.

  6. A safety-based decision making architecture for autonomous systems

    NASA Technical Reports Server (NTRS)

    Musto, Joseph C.; Lauderbaugh, L. K.

    1991-01-01

    Engineering systems designed specifically for space applications often exhibit a high level of autonomy in the control and decision-making architecture. As the level of autonomy increases, more emphasis must be placed on assimilating the safety functions normally executed at the hardware level or by human supervisors into the control architecture of the system. The development of a decision-making structure which utilizes information on system safety is detailed. A quantitative measure of system safety, called the safety self-information, is defined. This measure is analogous to the reliability self-information defined by McInroy and Saridis, but includes weighting of task constraints to provide a measure of both reliability and cost. An example is presented in which the safety self-information is used as a decision criterion in a mobile robot controller. The safety self-information is shown to be consistent with the entropy-based Theory of Intelligent Machines defined by Saridis.

  7. Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line

    DOEpatents

    Gaul, Christopher J.

    2001-01-01

    The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

  8. Total Quality Management and the System Safety Secretary

    NASA Technical Reports Server (NTRS)

    Elliott, Suzan E.

    1993-01-01

    The system safety secretary is a valuable member of the system safety team. As downsizing occurs to meet economic constraints, the Total Quality Management (TQM) approach is frequently adopted as a formula for success and, in some cases, for survival.

  9. Design and Analysis of a Continuous Split Typed Needle-Free Injection System for Animal Vaccination.

    PubMed

    Chen, Kai; Pan, Min; Liu, Tingting

    2017-01-01

    Liquid needle-free injection devices (NFIDs) employ a high-velocity liquid jet to deliver drugs and vaccine through transdermal injection. NFIDs for animal vaccination are more complicated than those used for human beings for their much larger and more flexible power sources, as well as rapid, repetitive and continuous injection features. In the paper, spring-powered NFID is designed for animal vaccine injection. For convenience, the device is a split into a power source and handheld injector. A mathematical model is proposed to calculate the injection pressure, taking into the account pressure loss and the strain energy loss in the bendable tube due to elastic deformation. An experimental apparatus was build to verify the calculation results. Under the same system conditions, the calculation results of the dynamic injection pressure match the experimental results. It is found that the bendable tube of the split typed NFID has significant impact on the profile of the injection pressure. The initial peak pressure is less than the initial peak pressure of NFID without bendable tube, and there is occurrence time lag of the peak pressure. The mathematical model is the first attempt to reveal the relationship between the injection pressure and the system variables of split typed NFID.

  10. Influence Map Methodology for Evaluating Systemic Safety Issues

    NASA Technical Reports Server (NTRS)

    2008-01-01

    "Raising the bar" in safety performance is a critical challenge for many organizations, including Kennedy Space Center. Contributing-factor taxonomies organize information about the reasons accidents occur and therefore are essential elements of accident investigations and safety reporting systems. Organizations must balance efforts to identify causes of specific accidents with efforts to evaluate systemic safety issues in order to become more proactive about improving safety. This project successfully addressed the following two problems: (1) methods and metrics to support the design of effective taxonomies are limited and (2) influence relationships among contributing factors are not explicitly modeled within a taxonomy.

  11. Assessment of injection practice in primary health care facilities of Shiraz, Iran.

    PubMed

    Mclaws, Mary-Louise; Ghahramani, Sulmaz; Palenik, Charles John; Keshtkar, Vahid; Askarian, Mehrdad

    2014-03-01

    Occupational risk for several bloodborne viruses is attributable to unsafe injection practices. To understand injection frequency and safety, we surveyed injection rates and factors influencing injection prescription in primary health care facilities and associated health clinics in Shiraz, Iran. We used both quantitative and qualitative approaches to study the frequency and safety of injections delivered in 27 primary health care facilities. We used observations and 3 data collecting tools. Patterns of 600 general practice physicians' (GPs) prescriptions were also reviewed. In-depth interviews to elicit the factors contributing to injection prescriptions were conducted. The annual per capita injection rate was 3.12. Corticosteroids were prescribed more frequently than antibiotics (P < .001). Knowledge of participants concerning transmission risks for 3 of the most common bloodborne infections (BBIs) was less than 75%. Factors affecting use of injections by GPs included strong patient preference for injections over oral medications and financial benefit for GPs, especially those in private practice settings. Frequency of therapeutic injections in the participating facilities in Shiraz was high. Sociocultural factors in the patient community and their beliefs in the effectiveness of injections exerted influence on GP prescribing practices. Programs for appropriate and safe injection practices should target GP and injection providers, as well as patients, informing them about alternative treatments and possible complications of unnecessary and unsafe injections. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.

  12. Pulverized solid injection system. Application to laboratory burners and pyrometric temperature measurements

    NASA Astrophysics Data System (ADS)

    Therssen, E.; Delfosse, L.

    1995-08-01

    The design and setting up of a pulverized solid injection system for use in laboratory burners is presented. The original dual system consists of a screw feeder coupled to an acoustic sower. This laboratory device allows a good regularity and stability of the particle-gas mixture transported to the burner in a large scale of mass powder and gas vector rate flow. The thermal history of the particles has been followed by optical measurements. The quality of the particle cloud injected in the burner has been validated by the good agreement between experimental and modeling particle temperature.

  13. Certification of highly complex safety-related systems.

    PubMed

    Reinert, D; Schaefer, M

    1999-01-01

    The BIA has now 15 years of experience with the certification of complex electronic systems for safety-related applications in the machinery sector. Using the example of machining centres this presentation will show the systematic procedure for verifying and validating control systems using Application Specific Integrated Circuits (ASICs) and microcomputers for safety functions. One section will describe the control structure of machining centres with control systems using "integrated safety." A diverse redundant architecture combined with crossmonitoring and forced dynamization is explained. In the main section the steps of the systematic certification procedure are explained showing some results of the certification of drilling machines. Specification reviews, design reviews with test case specification, statistical analysis, and walk-throughs are the analytical measures in the testing process. Systematic tests based on the test case specification, Electro Magnetic Interference (EMI), and environmental testing, and site acceptance tests on the machines are the testing measures for validation. A complex software driven system is always undergoing modification. Most of the changes are not safety-relevant but this has to be proven. A systematic procedure for certifying software modifications is presented in the last section of the paper.

  14. The Design of a Practical Enterprise Safety Management System

    NASA Astrophysics Data System (ADS)

    Gabbar, Hossam A.; Suzuki, Kazuhiko

    This book presents design guidelines and implementation approaches for enterprise safety management system as integrated within enterprise integrated systems. It shows new model-based safety management where process design automation is integrated with enterprise business functions and components. It proposes new system engineering approach addressed to new generation chemical industry. It will help both the undergraduate and professional readers to build basic knowledge about issues and problems of designing practical enterprise safety management system, while presenting in clear way, the system and information engineering practices to design enterprise integrated solution.

  15. Vibration Anesthesia for Pain Reduction During Intralesional Steroid Injection for Keloid Treatment.

    PubMed

    Park, Kui Young; Lee, Yohan; Hong, Ji Yeon; Chung, Won Soon; Kim, Myeung Nam; Kim, Beom Joon

    2017-05-01

    Patients suffer significant pain during intralesional steroid injection treatment for keloids and hypertrophic scars. Vibration anesthesia has been shown to effectively and safely alleviate pain sensations, likely by reducing pain transmission from peripheral receptors to the brain. The objective was to evaluate the efficacy, safety, and patient satisfaction associated with vibration anesthesia for reducing pain during intralesional corticosteroid injection. The authors recruited 40 patients with 58 keloids who were scheduled to undergo intralesional triamcinolone acetonide (TA) injections. Half of each keloid was injected with concomitant vibration anesthesia, whereas the other half was injected without vibration anesthesia. Pain experienced by patients during both procedures was assessed according to visual analog scale (VAS) score. The authors also assessed procedure safety. The mean VAS score during intralesional TA injection therapy without vibration was 5.88 ± 2.34. By contrast, the same patients yielded a mean VAS score during intralesional TA injection therapy with vibration of 3.28 ± 1.85; the difference between the mean scores was significant (p < .05). Thirty-nine (97.5%) patients tolerated this therapy well. Vibration anesthesia is a promising option for reducing pain during keloid treatment with intralesional steroid injection.

  16. Human factors systems approach to healthcare quality and patient safety

    PubMed Central

    Carayon, Pascale; Wetterneck, Tosha B.; Rivera-Rodriguez, A. Joy; Hundt, Ann Schoofs; Hoonakker, Peter; Holden, Richard; Gurses, Ayse P.

    2013-01-01

    Human factors systems approaches are critical for improving healthcare quality and patient safety. The SEIPS (Systems Engineering Initiative for Patient Safety) model of work system and patient safety is a human factors systems approach that has been successfully applied in healthcare research and practice. Several research and practical applications of the SEIPS model are described. Important implications of the SEIPS model for healthcare system and process redesign are highlighted. Principles for redesigning healthcare systems using the SEIPS model are described. Balancing the work system and encouraging the active and adaptive role of workers are key principles for improving healthcare quality and patient safety. PMID:23845724

  17. Safety systems in gamma irradiation facilities.

    PubMed

    Drndarevic, V

    1997-08-01

    A new electronic device has been developed to guard against individuals gaining entry through the product entry and exit ports into our irradiation facility for industrial sterilization. This device uses the output from electronic sensors and pressure mats to assure that only the transport cabins may pass through these ports. Any intention of personnel trespassing is detected, the process is stopped by the safety system, and the source is placed in safe position. Owing to a simple construction, the new device enables reliable operation, is inexpensive, easy to implement, and improves the existing safety systems.

  18. Models Extracted from Text for System-Software Safety Analyses

    NASA Technical Reports Server (NTRS)

    Malin, Jane T.

    2010-01-01

    This presentation describes extraction and integration of requirements information and safety information in visualizations to support early review of completeness, correctness, and consistency of lengthy and diverse system safety analyses. Software tools have been developed and extended to perform the following tasks: 1) extract model parts and safety information from text in interface requirements documents, failure modes and effects analyses and hazard reports; 2) map and integrate the information to develop system architecture models and visualizations for safety analysts; and 3) provide model output to support virtual system integration testing. This presentation illustrates the methods and products with a rocket motor initiation case.

  19. John M. Eisenberg Patient Safety Awards. System innovation: Veterans Health Administration National Center for Patient Safety.

    PubMed

    Heget, Jeffrey R; Bagian, James P; Lee, Caryl Z; Gosbee, John W

    2002-12-01

    In 1998 the Veterans Health Administration (VHA) created the National Center for Patient Safety (NCPS) to lead the effort to reduce adverse events and close calls systemwide. NCPS's aim is to foster a culture of safety in the Department of Veterans Affairs (VA) by developing and providing patient safety programs and delivering standardized tools, methods, and initiatives to the 163 VA facilities. To create a system-oriented approach to patient safety, NCPS looked for models in fields such as aviation, nuclear power, human factors, and safety engineering. Core concepts included a non-punitive approach to patient safety activities that emphasizes systems-based learning, the active seeking out of close calls, which are viewed as opportunities for learning and investigation, and the use of interdisciplinary teams to investigate close calls and adverse events through a root cause analysis (RCA) process. Participation by VA facilities and networks was voluntary. NCPS has always aimed to develop a program that would be applicable both within the VA and beyond. NCPS's full patient safety program was tested and implemented throughout the VA system from November 1999 to August 2000. Program components included an RCA system for use by caregivers at the front line, a system for the aggregate review of RCA results, information systems software, alerts and advisories, and cognitive acids. Following program implementation, NCPS saw a 900-fold increase in reporting of close calls of high-priority events, reflecting the level of commitment to the program by VHA leaders and staff.

  20. Subcritical and supercritical fuel injection and mixing in single and binary species systems

    NASA Astrophysics Data System (ADS)

    Roy, Arnab

    Subcritical and supercritical fluid injection using a single round injector into a quiescent atmosphere comprising single and binary species was investigated using optical diagnostics. Different disintegration and mixing modes are expected for the two cases. In the binary species case, the atmosphere comprised an inert gas of a different composition than that of the injected fluid. In single species case, the atmosphere consisted of the same species as that of the injected fluid. Density values were quantified and density gradient profiles were inferred from the experimental data. A novel method was applied for the detection of detailed structures throughout the entire jet center plane. Various combinations of injectant and chamber conditions were tested and a wide range of density ratios were covered. The subcritical cases demonstrated the importance of surface tension and inertial forces, while the supercritical cases showed no signs of surface tension and, in most situations, resembled the mixing characteristics of a gaseous jet injected into a gaseous environment. A comparison between the single and binary species systems has also been provided. A detailed laser calibration procedure was undertaken to account for the laser absorption through the gas and liquid phases and for fluorescence in the non-linear excitation regime for high laser pulse energy. Core lengths were measured for binary species cases and correlated with visualization results. An eigenvalue approach was taken to determine the location of maximum gradients for determining the core length. Jet divergence angles were also calculated and were found to increase with chamber-to-injectant density ratio for both systems. A model was proposed for the spreading angle dependence on density ratio for both single and binary species systems and was compared to existing theoretical studies and experimental work. Finally, a linear stability analysis was performed for the jet injected into both subcritical and

  1. Avation Safety Reporting System (ASRS) 40th Anniversary

    NASA Image and Video Library

    2016-09-28

    Avation Safety Reporting System (ASRS) 40th Anniversary lunch and open house at the Sunnyvale office. Thomas A Edwards, Deputy Center Director NASA Ames (Left), presents a plaque On the anniversary of the aviation safety reporting system, this award is in recognition of 18 years of outstanding leadership as Program Director, resulting in strong program growth, expanded partnership and a widely recognized impact on National and Global transportation safety. Presented to Linda J. Connell, ASRS Program Director (Right)

  2. SHORT-TERM SAFETY PROFILE OF INTRAVITREAL ZIV-AFLIBERCEPT.

    PubMed

    Chhablani, Jay; Narayanan, Raja; Mathai, Annie; Yogi, Rohit; Stewart, Michael

    2016-06-01

    To evaluate the safety of intravitreal ziv-aflibercept (Zaltrap) in the treatment choroidal neovascularization secondary to age-related macular degeneration. Eligible eyes with choroidal neovascularization secondary to age-related macular degeneration each received a single intravitreal injection of ziv-aflibercept. Comprehensive ophthalmic examinations and detailed systemic evaluations were performed at baseline and Days 1, 7, and 30 after injection, and International Society for Clinical Electrophysiology of Vision standard electroretinography was performed at baseline and Day 30. Primary outcome measures were safety parameters that included signs of clinical and electroretinographic toxicity. Secondary outcome measures included changes in best-corrected visual acuity and central subfield thickness. Twelve eyes of 12 patients were treated. None of the patients complained of blurred vision, ocular pain, or bulbar injection at any of the follow-up visits, nor was intraocular inflammation noted. There were no significant differences in implicit times, "a" and "b" wave amplitudes, or b/a ratios at 1 month when compared with baseline (P = 0.4). None of the patients experienced serious ocular or systemic adverse events. Mean best-corrected visual acuity improved only slightly at 30 days (LogMAR 0.45 ± 0.31 [Snellen equivalent: 20/60]) compared with baseline (LogMAR 0.37 ± 0.24 [Snellen equivalent: 20/50]; P = 0.51). Single intravitreal injections of ziv-aflibercept into eyes with neovascular age-related macular degeneration appear to be safe through 1 month. Ziv-aflibercept could become a safe, low-cost therapy for macular diseases in developing countries and in those where intravitreal aflibercept (Eylea) is not available.

  3. Repeated onabotulinumtoxin-a injections provide better results than single injection in treatment of painful bladder syndrome.

    PubMed

    Kuo, Hann-Chorng

    2013-01-01

    Onabotulinumtoxin-A (BoNT-A) is effective for the treatment of interstitial cystitis/painful bladder syndrome (IC/PBS). However, long-term follow-up does not show successful outcome after a single injection. To evaluate the efficacy and safety of repeated intravesical BoNT-A injections for treatment of IC/PBS and compare the success rates among patient groups receiving different injection numbers. Prospective interventional study. Tertiary medical center. Intravesical injection of 100 U of BoNT-A was performed in 81 patients every 6 months for up to 4 times or until patients' symptoms significantly improved. Patients who received a single injection served as active controls. Measured parameters included O'Leary-Sant symptom indexes (ICSI) and problem indexes (ICPI), visual analogue score (VAS) for pain, voiding diary variables, urodynamic parameters, maximal bladder capacity under anesthesia, glomerulation grade, and global response assessment. Multiple measurements and Kaplan-Meier analysis were used for comparison of consecutive data and success rates among groups. Among 81 patients, 20 received single injections, 19 received 2 injections, 12 received 3 injections, and 30 received 4 injections. The mean (± standard deviation) of ICSI, ICPI, total scores, VAS, functional bladder capacity, and daytime frequency all showed significant improvement after repeated BoNT-A treatment with different injections. Significantly better success rates were noted in patients who received 4 repeated injections (P = 0.0242) and 3 injections (P = 0.050), compared to those who received a single injection. However, there was no significant difference of long-term success rates among patients who received 2, 3, and 4 injections. Lack of placebo control group is the main limitation. Repeated intravesical BoNT-A injections were safe and effective for pain relief and they increased bladder capacity and provided a better long-term success rate than a single injection did for treatment of

  4. System interface for an integrated intelligent safety system (ISS) for vehicle applications.

    PubMed

    Hannan, Mahammad A; Hussain, Aini; Samad, Salina A

    2010-01-01

    This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications.

  5. System Interface for an Integrated Intelligent Safety System (ISS) for Vehicle Applications

    PubMed Central

    Hannan, Mahammad A.; Hussain, Aini; Samad, Salina A.

    2010-01-01

    This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications. PMID:22205861

  6. [Onyx embolization for treatment of dural arteriovenous fistula: comparison of long- distance versus routine injection method].

    PubMed

    He, Xiao-Yan; Zhang, Guo-Zhong; Li, Ming-Zhou; Wang, Gang; Liu, Dan; Qi, Song-Tao; Li, Wei-Guang; Feng, Wen-Feng

    2016-03-01

    To compare the efficacy, clinical characteristics, safety, injection time and radiation exposure of Onyx embolization using a long-distance injection method and routine injection method for management of dural arteriovenous fistula (DAVF). The clinical data were retrospectively analyzed in 59 patients with DAVF treated with Onyx embolization using long-distance injection method (28 patients) and routine injection method (31 patients). The efficacy, safety, injection time and radiation exposure during Onyx embolization were compared between the two injections methods. The average radiation dose exposure to the surgeon per procedure was significantly lower in the long-distance injection group than in the routine group. The injection time (P=0.53), injection volume (P=0.78), number of supply arteries (P=0.80), Cognard types (P=0.67), and effect of embolization (P=0.88) were all similar between the two groups. Endovaseular treatment of intracranial DAVF with Onyx embolization using the long-distance injection method is feasible, safe and effective and can reduce the radiation exposure to the surgeon.

  7. 30 CFR 250.804 - Production safety-system testing and records.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 2 2013-07-01 2013-07-01 false Production safety-system testing and records... Gas Production Safety Systems § 250.804 Production safety-system testing and records. (a) Inspection... devices operating at temperatures which could ignite a methane-air mixture shall not be used. All...

  8. 30 CFR 250.804 - Production safety-system testing and records.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 2 2012-07-01 2012-07-01 false Production safety-system testing and records... Gas Production Safety Systems § 250.804 Production safety-system testing and records. (a) Inspection... devices operating at temperatures which could ignite a methane-air mixture shall not be used. All...

  9. 30 CFR 250.804 - Production safety-system testing and records.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 2 2014-07-01 2014-07-01 false Production safety-system testing and records... Gas Production Safety Systems § 250.804 Production safety-system testing and records. (a) Inspection... devices operating at temperatures which could ignite a methane-air mixture shall not be used. All...

  10. Comprehensive Safety Analysis 2010 Safety Measurement System (SMS) Methodology, Version 2.1 Revised December 2010

    DOT National Transportation Integrated Search

    2010-12-01

    This report documents the Safety Measurement System (SMS) methodology developed to support the Comprehensive Safety Analysis 2010 (CSA 2010) Initiative for the Federal Motor Carrier Safety Administration (FMCSA). The SMS is one of the major tools for...

  11. Consumer product safety: A systems problem

    NASA Technical Reports Server (NTRS)

    Clark, C. C.

    1971-01-01

    The manufacturer, tester, retailer, consumer, repairer disposer, trade and professional associations, national and international standards bodies, and governments in several roles are all involved in consumer product safety. A preliminary analysis, drawing on system safety techniques, is utilized to distinguish the inter-relations of these many groups and the responsibilities that they are or could take for product safety, including the slow accident hazards as well as the more commonly discussed fast accident hazards. The importance of interactive computer aided information flow among these groups is particularly stressed.

  12. Safety Characteristics in System Application Software for Human Rated Exploration

    NASA Technical Reports Server (NTRS)

    Mango, E. J.

    2016-01-01

    NASA and its industry and international partners are embarking on a bold and inspiring development effort to design and build an exploration class space system. The space system is made up of the Orion system, the Space Launch System (SLS) and the Ground Systems Development and Operations (GSDO) system. All are highly coupled together and dependent on each other for the combined safety of the space system. A key area of system safety focus needs to be in the ground and flight application software system (GFAS). In the development, certification and operations of GFAS, there are a series of safety characteristics that define the approach to ensure mission success. This paper will explore and examine the safety characteristics of the GFAS development.

  13. Simulation of the injection damping and resonance correction systems for the HEB of the SSC

    NASA Astrophysics Data System (ADS)

    Li, M.; Zhang, P.; Machida, S.

    1993-12-01

    An injection damping and resonance correction system for the High Energy Booster (HEB) of the Superconducting Super Collider (SSC) was investigated by means of multiparticle tracking. For an injection damping study, the code Simpsons is modified to utilize two Beam Position Monitors (BPM) and two dampers. The particles of 200 Gev/c, numbered 1024 or more, with Gaussian distribution in 6-D phase space are injected into the HEB with certain injection offsets. The whole bunch of particles is then kicked in proportion to the BPM signals with some upper limit. Tracking these particles up to several hundred turns while the damping system is acting shows the turn-by-turn emittance growth, which is caused by the tune spread due to nonlinearity of the lattice and residual chromaticity with synchrotron oscillations. For a resonance correction study, the operating tune is scanned as a function of time so that a bunch goes through a resonance. The performance of the resonance correction system is demonstrated. We optimize the system parameters which satisfy the emittance budget of the HEB, taking into account the realistic hardware requirement.

  14. Analyzing system safety in lithium-ion grid energy storage

    DOE PAGES

    Rosewater, David; Williams, Adam

    2015-10-08

    As grid energy storage systems become more complex, it grows more di cult to design them for safe operation. This paper first reviews the properties of lithium-ion batteries that can produce hazards in grid scale systems. Then the conventional safety engineering technique Probabilistic Risk Assessment (PRA) is reviewed to identify its limitations in complex systems. To address this gap, new research is presented on the application of Systems-Theoretic Process Analysis (STPA) to a lithium-ion battery based grid energy storage system. STPA is anticipated to ll the gaps recognized in PRA for designing complex systems and hence be more e ectivemore » or less costly to use during safety engineering. It was observed that STPA is able to capture causal scenarios for accidents not identified using PRA. Additionally, STPA enabled a more rational assessment of uncertainty (all that is not known) thereby promoting a healthy skepticism of design assumptions. Lastly, we conclude that STPA may indeed be more cost effective than PRA for safety engineering in lithium-ion battery systems. However, further research is needed to determine if this approach actually reduces safety engineering costs in development, or improves industry safety standards.« less

  15. Analyzing system safety in lithium-ion grid energy storage

    NASA Astrophysics Data System (ADS)

    Rosewater, David; Williams, Adam

    2015-12-01

    As grid energy storage systems become more complex, it grows more difficult to design them for safe operation. This paper first reviews the properties of lithium-ion batteries that can produce hazards in grid scale systems. Then the conventional safety engineering technique Probabilistic Risk Assessment (PRA) is reviewed to identify its limitations in complex systems. To address this gap, new research is presented on the application of Systems-Theoretic Process Analysis (STPA) to a lithium-ion battery based grid energy storage system. STPA is anticipated to fill the gaps recognized in PRA for designing complex systems and hence be more effective or less costly to use during safety engineering. It was observed that STPA is able to capture causal scenarios for accidents not identified using PRA. Additionally, STPA enabled a more rational assessment of uncertainty (all that is not known) thereby promoting a healthy skepticism of design assumptions. We conclude that STPA may indeed be more cost effective than PRA for safety engineering in lithium-ion battery systems. However, further research is needed to determine if this approach actually reduces safety engineering costs in development, or improves industry safety standards.

  16. An Autonomous Flight Safety System

    NASA Technical Reports Server (NTRS)

    Bull, James B.; Lanzi, Raymond J.

    2007-01-01

    The Autonomous Flight Safety System (AFSS) being developed by NASA s Goddard Space Flight Center s Wallops Flight Facility and Kennedy Space Center has completed two successful developmental flights and is preparing for a third. AFSS has been demonstrated to be a viable architecture for implementation of a completely vehicle based system capable of protecting life and property in event of an errant vehicle by terminating the flight or initiating other actions. It is capable of replacing current human-in-the-loop systems or acting in parallel with them. AFSS is configured prior to flight in accordance with a specific rule set agreed upon by the range safety authority and the user to protect the public and assure mission success. This paper discusses the motivation for the project, describes the method of development, and presents an overview of the evolving architecture and the current status.

  17. Clinicopathologic findings following intra-articular injection of autologous and allogeneic placentally derived equine mesenchymal stem cells in horses.

    PubMed

    Carrade, Danielle D; Owens, Sean D; Galuppo, Larry D; Vidal, Martin A; Ferraro, Gregory L; Librach, Fred; Buerchler, Sabine; Friedman, Michael S; Walker, Naomi J; Borjesson, Dori L

    2011-04-01

    The development of an allogeneic mesenchymal stem cell (MSC) product to treat equine disorders would be useful; however, there are limited in vivo safety data for horses. We hypothesized that the injection of self (autologous) and non-self (related allogeneic or allogeneic) MSC would not elicit significant alterations in physical examination, gait or synovial fluid parameters when injected into the joints of healthy horses. Sixteen healthy horses were used in this study. Group 1 consisted of foals (n = 6), group 2 consisted of their dams (n = 5) and group 3 consisted of half-siblings (n = 5) to group 1 foals. Prior to injection, MSC were phenotyped. Placentally derived MSC were injected into contralateral joints and MSC diluent was injected into a separate joint (control). An examination, including lameness evaluation and synovial fluid analysis, was performed at 0, 24, 48 and 72 h post-injection. MSC were major histocompatibility complex (MHC) I positive, MHC II negative and CD86 negative. Injection of allogeneic MSC did not elicit a systemic response. Local responses such as joint swelling or lameness were minimal and variable. Intra-articular MSC injection elicited marked inflammation within the synovial fluid (as measured by nucleated cell count, neutrophil number and total protein concentration). However, there were no significant differences between the degree and type of inflammation elicited by self and non-self-MSC. The healthy equine joint responds similarly to a single intra-articular injection of autologous and allogeneic MSC. This pre-clinical safety study is an important first step in the development of equine allogeneic stem cell therapies.

  18. A Well-Controlled Nucleus Pulposus Tissue Culture System with Injection Port for Evaluating Regenerative Therapies.

    PubMed

    Arkesteijn, Irene T M; Mouser, Vivian H M; Mwale, Fackson; van Dijk, Bart G M; Ito, Keita

    2016-05-01

    In vitro evaluation of nucleus pulposus (NP) tissue regeneration would be useful, but current systems for NP culture are not ideal for injections. The aim of this study was to develop a long-term culture system for NP tissue that allows injections of regenerative agents. Bovine caudal NPs were harvested and placed in the newly designed culture system. After equilibration of the tissue to 0.3 MPa the volume was fixed and the tissue was cultured for 28 days. The cell viability and extracellular matrix composition remained unchanged during the culture period and gene expression profiles were similar to those obtained in earlier studies. Furthermore, to test the responsiveness of bovine caudal NPs in the system, samples were cultured for 4 days and injected twice (day 1 and 3) with (1) PBS, (2) Link-N, for regeneration, and (3) TNF-α, for degeneration. It was shown that TNF-α increased COX2 gene expression, whereas no effect of Link-N was detected. In conclusion, the newly designed system allows long-term culture of NP tissue, wherein tissue reactions to injected stimulants can be observed.

  19. Functional Safety of Hybrid Laser Safety Systems - How can a Combination between Passive and Active Components Prevent Accidents?

    NASA Astrophysics Data System (ADS)

    Lugauer, F. P.; Stiehl, T. H.; Zaeh, M. F.

    Modern laser systems are widely used in industry due to their excellent flexibility and high beam intensities. This leads to an increased hazard potential, because conventional laser safety barriers only offer a short protection time when illuminated with high laser powers. For that reason active systems are used more and more to prevent accidents with laser machines. These systems must fulfil the requirements of functional safety, e.g. according to IEC 61508, which causes high costs. The safety provided by common passive barriers is usually unconsidered in this context. In the presented approach, active and passive systems are evaluated from a holistic perspective. To assess the functional safety of hybrid safety systems, the failure probability of passive barriers is analysed and added to the failure probability of the active system.

  20. Safety evaluation of intersection conflict warning system.

    DOT National Transportation Integrated Search

    2016-06-01

    FHWA organized a pooled fund study of 40 States to evaluate low-cost safety strategies as part of its strategic highway safety effort. One of the strategies selected for evaluation was intersection conflict warning systems (ICWSs). This strategy is i...

  1. Proposed system safety design and test requirements for the microlaser ordnance system

    NASA Technical Reports Server (NTRS)

    Stoltz, Barb A.; Waldo, Dale F.

    1993-01-01

    Safety for pyrotechnic ignition systems is becoming a major concern for the military. In the past twenty years, stray electromagnetic fields have steadily increased during peacetime training missions and have dramatically increased during battlefield missions. Almost all of the ordnance systems in use today depend on an electrical bridgewire for ignition. Unfortunately, the bridgewire is the cause of the majority of failure modes. The common failure modes include the following: broken bridgewires; transient RF power, which induces bridgewire heating; and cold temperatures, which contracts the explosive mix away from the bridgewire. Finding solutions for these failure modes is driving the costs of pyrotechnic systems up. For example, analyses are performed to verify that the system in the environment will not see more energy than 20 dB below the 'No-fire' level. Range surveys are performed to determine the operational, storage, and transportation RF environments. Cryogenic tests are performed to verify the bridgewire to mix interface. System requirements call for 'last minute installation,' 'continuity checks after installation,' and rotating safety devices to 'interrupt the explosive train.' As an alternative, MDESC has developed a new approach based upon our enabling laser diode technology. We believe that Microlaser initiated ordnance offers a unique solution to the bridgewire safety concerns. For this presentation, we will address, from a system safety viewpoint, the safety design and the test requirements for a Microlaser ordnance system. We will also review how this system could be compliant to MIL-STD-1576 and DOD-83578A and the additional necessary requirements.

  2. Learning from Taiwan patient-safety reporting system.

    PubMed

    Lin, Chung-Chih; Shih, Chung-Liang; Liao, Hsun-Hsiang; Wung, Cathy H Y

    2012-12-01

    The aim of this study is to create a national database to record incidents that endanger patient safety. We try to identify systemic problems in hospitals in order to avoid safety incidents in the future and improve the quality of healthcare. The Taiwan Patient Safety Reporting System employs a voluntary notification model. We define 13 types of patient safety incidents, and the reports of different types of incidents are recorded using common terminology. Statistical analysis is used to identify the incident type, time of occurrence, location, person who reported the incident, and possible reasons for frequently occurring incidents. There were 340 hospitals that joined this program from 2005 to 2010. Over 128,271 incident events were reported and analyzed. The three most common incidents were drug-related incidents, falls, and endo tube related incidents. By analyzing the time of occurrence of incidents, we found that drug-related incidents usually occurred between 8 and 10 am. Falls and endo tube incidents usually occurred between 4 and 6 am. The most common location was wards (57.6%), followed by intensive care areas (13.5%), and pharmacies (9.1%). Among hospital staff, nurses reported the highest number of incidents (68.9%), followed by pharmacists (14.5%) and administrative staff (5.5%). The number of incidents reported by doctors was much lower (1.2%). Most staff members who reported incidents had been working for less than five years (58.1%). The unified reporting system was found to improve the recording and analysis of patient safety incidents. To encourage hospital staff to report incidents, hospitals need to be assisted in establishing an internal report and management system for safety incidents. Hospitals also need a protection mechanism to allow staff members to report incidents without the fear of punishment. By identifying the root causes of safety incidents and sharing the lessons learned across hospitals is the only way such incidents can be

  3. 33 CFR 96.220 - What makes up a safety management system?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false What makes up a safety management... SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.220 What makes up a safety management system? (a) The...

  4. [B-BS and occupational health and safety management systems].

    PubMed

    Bacchetta, Adriano Paolo

    2010-01-01

    The objective of a SGSL is the "prevention" agreement as approach of "pro-active" toward the safety at work through the construction of an integrated managerial system in synergic an dynamic way with the business organization, according to continuous improvement principles. Nevertheless the adoption of a SGSL, not could guarantee by itself the obtainment of the full effectiveness than projected and every individual's adhesion to it, must guarantee it's personal involvement in proactive way, so that to succeed to actual really how much hypothesized to systemic level to increase the safety in firm. The objective of a behavioral safety process that comes to be integrated in a SGSL, it has the purpose to succeed in implementing in firm a process of cultural change that raises the workers social group fundamental safety value, producing an ample and full involvement of all in the activities of safety at work development. SGSL = Occupational Health and Safety Management System.

  5. Patient Safety Threat - Syringe Reuse

    MedlinePlus

    ... Fingerstick Devices Clinical Reminder: Insulin Pens Publications Infection Control Assessment of Ambulatory Surgical Centers Meetings Insurance Stakeholders Meeting – December 2011 Ambulatory Surgical Centers – October 2010 Safety by Design – May 2010 Sticking with Safety – May 2010 Injection ...

  6. Development of a Comprehensive Database System for Safety Analyst

    PubMed Central

    Paz, Alexander; Veeramisti, Naveen; Khanal, Indira; Baker, Justin

    2015-01-01

    This study addressed barriers associated with the use of Safety Analyst, a state-of-the-art tool that has been developed to assist during the entire Traffic Safety Management process but that is not widely used due to a number of challenges as described in this paper. As part of this study, a comprehensive database system and tools to provide data to multiple traffic safety applications, with a focus on Safety Analyst, were developed. A number of data management tools were developed to extract, collect, transform, integrate, and load the data. The system includes consistency-checking capabilities to ensure the adequate insertion and update of data into the database. This system focused on data from roadways, ramps, intersections, and traffic characteristics for Safety Analyst. To test the proposed system and tools, data from Clark County, which is the largest county in Nevada and includes the cities of Las Vegas, Henderson, Boulder City, and North Las Vegas, was used. The database and Safety Analyst together help identify the sites with the potential for safety improvements. Specifically, this study examined the results from two case studies. The first case study, which identified sites having a potential for safety improvements with respect to fatal and all injury crashes, included all roadway elements and used default and calibrated Safety Performance Functions (SPFs). The second case study identified sites having a potential for safety improvements with respect to fatal and all injury crashes, specifically regarding intersections; it used default and calibrated SPFs as well. Conclusions were developed for the calibration of safety performance functions and the classification of site subtypes. Guidelines were provided about the selection of a particular network screening type or performance measure for network screening. PMID:26167531

  7. Model-Driven Safety Analysis of Closed-Loop Medical Systems

    PubMed Central

    Pajic, Miroslav; Mangharam, Rahul; Sokolsky, Oleg; Arney, David; Goldman, Julian; Lee, Insup

    2013-01-01

    In modern hospitals, patients are treated using a wide array of medical devices that are increasingly interacting with each other over the network, thus offering a perfect example of a cyber-physical system. We study the safety of a medical device system for the physiologic closed-loop control of drug infusion. The main contribution of the paper is the verification approach for the safety properties of closed-loop medical device systems. We demonstrate, using a case study, that the approach can be applied to a system of clinical importance. Our method combines simulation-based analysis of a detailed model of the system that contains continuous patient dynamics with model checking of a more abstract timed automata model. We show that the relationship between the two models preserves the crucial aspect of the timing behavior that ensures the conservativeness of the safety analysis. We also describe system design that can provide open-loop safety under network failure. PMID:24177176

  8. Model-Driven Safety Analysis of Closed-Loop Medical Systems.

    PubMed

    Pajic, Miroslav; Mangharam, Rahul; Sokolsky, Oleg; Arney, David; Goldman, Julian; Lee, Insup

    2012-10-26

    In modern hospitals, patients are treated using a wide array of medical devices that are increasingly interacting with each other over the network, thus offering a perfect example of a cyber-physical system. We study the safety of a medical device system for the physiologic closed-loop control of drug infusion. The main contribution of the paper is the verification approach for the safety properties of closed-loop medical device systems. We demonstrate, using a case study, that the approach can be applied to a system of clinical importance. Our method combines simulation-based analysis of a detailed model of the system that contains continuous patient dynamics with model checking of a more abstract timed automata model. We show that the relationship between the two models preserves the crucial aspect of the timing behavior that ensures the conservativeness of the safety analysis. We also describe system design that can provide open-loop safety under network failure.

  9. Modeling and investigation of refrigeration system performance with two-phase fluid injection in a scroll compressor

    NASA Astrophysics Data System (ADS)

    Gu, Rui

    Vapor compression cycles are widely used in heating, refrigerating and air-conditioning. A slight performance improvement in the components of a vapor compression cycle, such as the compressor, can play a significant role in saving energy use. However, the complexity and cost of these improvements can block their application in the market. Modifying the conventional cycle configuration can offer a less complex and less costly alternative approach. Economizing is a common modification for improving the performance of the refrigeration cycle, resulting in decreasing the work required to compress the gas per unit mass. Traditionally, economizing requires multi-stage compressors, the cost of which has restrained the scope for practical implementation. Compressors with injection ports, which can be used to inject economized refrigerant during the compression process, introduce new possibilities for economization with less cost. This work focuses on computationally investigating a refrigeration system performance with two-phase fluid injection, developing a better understanding of the impact of injected refrigerant quality on refrigeration system performance as well as evaluating the potential COP improvement that injection provides based on refrigeration system performance provided by Copeland.

  10. Characterization of a high-pressure diesel fuel injection system as a control technology option to improve engine performance and reduce exhaust emissions

    NASA Technical Reports Server (NTRS)

    Mcfadden, J. J.; Dezelick, R. A.; Barrows, R. R.

    1983-01-01

    Test results from a high pressure electronically controlled fuel injection system are compared with a commercial mechanical injection system on a single cylinder, diesel test engine using an inlet boost pressure of 2.6:1. The electronic fuel injection system achieved high pressure by means of a fluid intensifier with peak injection pressures of 47 to 69 MPa. Reduced exhaust emissions were demonstrated with an increasing rate of injection followed by a fast cutoff of injection. The reduction in emissions is more responsive to the rate of injection and injection timing than to high peak injection pressure.

  11. Local Helicity Injection Systems for Non-solenoidal Startup in the PEGASUS Toroidal Experiment

    NASA Astrophysics Data System (ADS)

    Perry, J. M.; Barr, J. L.; Bongard, M. W.; Fonck, R. J.; Hinson, E. T.; Lewicki, B. T.; Redd, A. J.

    2013-10-01

    Local helicity injection is being developed in the PEGASUS Toroidal Experiment for non-solenoidal startup in spherical tokamaks. The effective loop voltage due to helicity injection scales with the area of the injectors, requiring the development of electron current injectors with areas much larger than the 2 cm2 plasma arc injectors used to date. Solid and gas-effused metallic electrodes were found to be unusable due to reduced injector area utilization from localized cathode spots and narrow operational regimes. An integrated array of 8 compact plasma arc sources is thus being developed for high current startup. It employs two monolithic power systems, for the plasma arc sources and the bias current extraction system. The array effectively eliminates impurity fueling from plasma-material interaction by incorporating a local scraper-limiter and conical-frustum bias electrodes to mitigate the effects of cathode spots. An energy balance model of helicity injection indicates that the resulting 20 cm2 of total injection area should provide sufficient current drive to reach 0.3 MA. At that level, helicity injection drive exceeds that from poloidal induction, which is the relevant operational regime for large-scale spherical tokamaks. Future placement of the injector array near an expanded boundary divertor region will test simultaneous optimization of helicity drive and the Taylor relaxation current limit. Work supported by US DOE Grant DE-FG02-96ER54375.

  12. Defining the pharmaceutical system to support proactive drug safety.

    PubMed

    Lewis, Vicki R; Hernandez, Angelica; Meadors, Margaret

    2013-02-01

    The military, aviation, nuclear, and transportation industries have transformed their safety records by using a systems approach to safety and risk mitigation. This article creates a preliminary model of the U.S. pharmaceutical system using available literature including academic publications, policies, and guidelines established by regulatory bodies and drug industry trade publications. Drawing from the current literature, the goals, roles, and individualized processes of pharmaceutical subsystems will be defined. Defining the pharmaceutical system provides a vehicle to assess and address known problems within the system, and provides a means to conduct proactive risk analyses, which would create significant pharmaceutical safety advancement.

  13. CRISPR-Cas systems exploit viral DNA injection to establish and maintain adaptive immunity.

    PubMed

    Modell, Joshua W; Jiang, Wenyan; Marraffini, Luciano A

    2017-04-06

    Clustered regularly interspaced short palindromic repeats (CRISPR)-Cas systems provide protection against viral and plasmid infection by capturing short DNA sequences from these invaders and integrating them into the CRISPR locus of the prokaryotic host. These sequences, known as spacers, are transcribed into short CRISPR RNA guides that specify the cleavage site of Cas nucleases in the genome of the invader. It is not known when spacer sequences are acquired during viral infection. Here, to investigate this, we tracked spacer acquisition in Staphylococcus aureus cells harbouring a type II CRISPR-Cas9 system after infection with the staphylococcal bacteriophage ϕ12. We found that new spacers were acquired immediately after infection preferentially from the cos site, the viral free DNA end that is first injected into the cell. Analysis of spacer acquisition after infection with mutant phages demonstrated that most spacers are acquired during DNA injection, but not during other stages of the viral cycle that produce free DNA ends, such as DNA replication or packaging. Finally, we showed that spacers acquired from early-injected genomic regions, which direct Cas9 cleavage of the viral DNA immediately after infection, provide better immunity than spacers acquired from late-injected regions. Our results reveal that CRISPR-Cas systems exploit the phage life cycle to generate a pattern of spacer acquisition that ensures a successful CRISPR immune response.

  14. Extemporaneously preparative biodegradable injectable polymer systems exhibiting temperature-responsive irreversible gelation.

    PubMed

    Yoshida, Yasuyuki; Takata, Kazuyuki; Takai, Hiroki; Kawahara, Keisuke; Kuzuya, Akinori; Ohya, Yuichi

    2017-10-01

    On clinical application of biodegradable injectable polymer (IP) systems, quick extemporaneous preparation of IP formulations and longer duration time gel state after injection into the body are the important targets to be developed. Previously, we had reported temperature-responsive covalent gelation systems via bio-orthogonal thiol-ene reaction by 'mixing strategy' of amphiphilic biodegradable tri-block copolymer (tri-PCG) attaching acryloyl groups on both termini (tri-PCG-Acryl) with reactive polythiol. In other previous works, we found 'freeze-dry with PEG/dispersion' method as quick extemporaneous preparation method of biodegradable IP formulations. In this study, we applied this quick preparative method to the temperature-triggered covalent gelation system. The instant formulation (D-sample) could be prepared by 'freeze-dry with PEG/dispersion' just mixing of tri-PCG-Acryl micelle dispersion and tri-PCG/DPMP micelle dispersion with PEG, that can be prepared in 30 s from the dried samples. The obtained D-sample showed irreversible gelation and long duration time of gel state, which was basically the same as the formulations prepared by the usual heating dissolution method (S-sample). Interestingly, the D-sample could maintain its sol state for a longer time (24 h) after preparing the formulation at r.t. compared with the S-sample, which became a gel in 3 h after preparing. The IP system showed good biocompatibility and long duration time of the gel state after subcutaneous implantation. These characteristics of D-samples, quick extemporaneous preparation and high stability in the sol state before injection, would be very convenient in a clinical setting.

  15. Computer-aided injection molding system

    NASA Astrophysics Data System (ADS)

    Wang, K. K.; Shen, S. F.; Cohen, C.; Hieber, C. A.; Isayev, A. I.

    1982-10-01

    Achievements are reported in cavity-filling simulation, modeling viscoelastic effects, measuring and predicting frozen-in birefringence in molded parts, measuring residual stresses and associated mechanical properties of molded parts, and developing an interactive mold-assembly design program and an automatic NC maching data generation and verification program. The Cornell Injection Molding Program (CIMP) consortium is discussed as are computer user manuals that have been published by the consortium. Major tasks which should be addressed in future efforts are listed, including: (1) predict and experimentally determine the post-fillin behavior of thermoplastics; (2) simulate and experimentally investigate the injection molding of thermosets and filled materials; and (3) further investigate residual stresses, orientation and mechanical properties.

  16. Requirements Analysis for the Army Safety Management Information System (ASMIS)

    DTIC Science & Technology

    1989-03-01

    8217_>’ Telephone Number « .. PNL-6819 Limited Distribution Requirements Analysis for the Army Safety Management Information System (ASMIS) Final...PNL-6819 REQUIREMENTS ANALYSIS FOR THE ARMY SAFETY MANAGEMENT INFORMATION SYSTEM (ASMIS) FINAL REPORT J. S. Littlefield A. L. Corrigan March...accidents. This accident data is available under the Army Safety Management Information System (ASMIS) which is an umbrella for many databases

  17. Advancing a sociotechnical systems approach to workplace safety--developing the conceptual framework.

    PubMed

    Carayon, Pascale; Hancock, Peter; Leveson, Nancy; Noy, Ian; Sznelwar, Laerte; van Hootegem, Geert

    2015-01-01

    Traditional efforts to deal with the enormous problem of workplace safety have proved insufficient, as they have tended to neglect the broader sociotechnical environment that surrounds workers. Here, we advocate a sociotechnical systems approach that describes the complex multi-level system factors that contribute to workplace safety. From the literature on sociotechnical systems, complex systems and safety, we develop a sociotechnical model of workplace safety with concentric layers of the work system, socio-organisational context and the external environment. The future challenges that are identified through the model are highlighted. Understanding the environmental, organisational and work system factors that contribute to workplace safety will help to develop more effective and integrated solutions to deal with persistent workplace safety problems. Solutions to improve workplace safety need to recognise the broad sociotechnical system and the respective interactions between the system elements and levels.

  18. Safety Aspects of Big Cryogenic Systems Design

    NASA Astrophysics Data System (ADS)

    Chorowski, M.; Fydrych, J.; Poliński, J.

    2010-04-01

    Superconductivity and helium cryogenics are key technologies in the construction of large scientific instruments, like accelerators, fusion reactors or free electron lasers. Such cryogenic systems may contain more than hundred tons of helium, mostly in cold and high-density phases. In spite of the high reliability of the systems, accidental loss of the insulation vacuum, pipe rupture or rapid energy dissipation in the cold helium can not be overlooked. To avoid the danger of over-design pressure rise in the cryostats, they need to be equipped with a helium relief system. Such a system is comprised of safety valves, bursting disks and optionally cold or warm quench lines, collectors and storage tanks. Proper design of the helium safety relief system requires a good understanding of worst case scenarios. Such scenarios will be discussed, taking into account different possible failures of the cryogenic system. In any case it is necessary to estimate heat transfer through degraded vacuum superinsulation and mass flow through the valves and safety disks. Even if the design of the helium relief system does not foresee direct helium venting into the environment, an occasional emergency helium spill may happen. Helium propagation in the atmosphere and the origins of oxygen-deficiency hazards will be discussed.

  19. The carrier safety measurement system (CSMS) effectiveness test by behavior analysis and safety improvement categories (BASICs)

    DOT National Transportation Integrated Search

    2014-01-24

    The Carrier Safety Measurement System (CSMS) is the Federal Motor Carrier Safety Administrations (FMCSA's) workload prioritization tool. This tool is used to identify carriers with potential safety issues so that they are subject to interventions ...

  20. Electrokinetic injection techniques in microfluidic chips.

    PubMed

    Fu, L M; Yang, R J; Lee, G B; Liu, H H

    2002-10-01

    The separation efficiency of a microfluidic chip is influenced to a significant degree by the flow field conditions within the injection microchannel. Therefore, an understanding of the physics of the flow within this channel is beneficial in the design and operation of such a system. The configuration of an injection system is determined by the volume of the sample plug that is to be delivered to the separation process. Accordingly, this paper addresses the design and testing of injection systems with a variety of configurations, including a simple cross, a double-T, and a triple-T configuration. This paper also presents the design of a unique multi-T injection configuration. Each injection system cycles through a predetermined series of steps, in which the electric field magnitude and distribution within the various channels is strictly manipulated, to effectuate a virtual valve. The uniquemulti-T configuration injection system presented within this paper has the ability to simulate the functions of the cross, double-T, and triple-T systems through appropriate manipulations of the electric field within its various channels. In other words, the proposed design successfully combines several conventional injection systems within a single microfluidic chip.

  1. Experimental and Analytical Determination of the Motion of Hydraulically Operated Valve Stems in Oil Engine Injection Systems

    NASA Technical Reports Server (NTRS)

    Gelalles, A G; Rothrock, A M

    1930-01-01

    This research on the pressure variations in the injection system of the N.A.C.A. Spray Photography Equipment and on the effects of these variations on the motion of the timing valve stem was undertaken in connection with the study of fuel injection systems for high-speed oil engines. The methods of analysis of the pressure variations and the general equation for the motion of the spring-loaded stem for the timing valve are applicable to a spring-loaded automatic injection valve, and in general to all hydraulically operated valves. A sample calculation for a spring-loaded automatic injection valve is included.

  2. Vertical migration of municipal wastewater in deep injection well systems, South Florida, USA

    NASA Astrophysics Data System (ADS)

    Maliva, Robert G.; Guo, Weixing; Missimer, Thomas

    2007-11-01

    Deep well injection is widely used in South Florida, USA for wastewater disposal largely because of the presence of an injection zone (“boulder zone” of Floridan Aquifer System) that is capable of accepting very large quantities of fluids, in some wells over 75,000 m3/day. The greatest potential risk to public health associated with deep injection wells in South Florida is vertical migration of wastewater, containing pathogenic microorganisms and pollutants, into brackish-water aquifer zones that are being used for alternative water-supply projects such as aquifer storage and recovery. Upwards migration of municipal wastewater has occurred in a minority of South Florida injection systems. The results of solute-transport modeling using the SEAWAT program indicate that the measured vertical hydraulic conductivities of the rock matrix would allow for only minimal vertical migration. Fracturing at some sites increased the equivalent average vertical hydraulic conductivity of confining zone strata by approximately four orders of magnitude and allowed for vertical migration rates of up 80 m/year. Even where vertical migration was rapid, the documented transit times are likely long enough for the inactivation of pathogenic microorganisms.

  3. Percutaneous Direct Needle Puncture and Transcatheter N-butyl Cyanoacrylate Injection Techniques for the Embolization of Pseudoaneurysms and Aneurysms of Arteries Supplying the Hepato-pancreato-biliary System and Gastrointestinal Tract

    PubMed Central

    Yadav, Rajanikant R; Boruah, Deb K; Bhattacharyya, Vishwaroop; Prasad, Raghunandan; Kumar, Sheo; Saraswat, V A; Kapoor, V K; Saxena, Rajan

    2016-01-01

    Aims: The aim of this study was to evaluate the safety and clinical efficacy of percutaneous direct needle puncture and transcatheter N-butyl cyanoacrylate (NBCA) injection techniques for the embolization of pseudoaneurysms and aneurysms of arteries supplying the hepato-pancreato-biliary (HPB) system and gastrointestinal (GI) tract. Subjects and Methods: A hospital-based cross-sectional retrospective study was conducted, where the study group comprised 11 patients with pseudoaneurysms/aneurysms of arteries supplying the HPB system and GI tract presenting to a tertiary care center from January 2015 to June 2016. Four patients (36.4%) underwent percutaneous direct needle puncture of pseudoaneurysms with NBCA injection, 3 patients (27.3%) underwent transcatheter embolization with NBCA as sole embolic agent, and in 4 patients (36.4%), transcatheter NBCA injection was done along with coil embolization. Results: This retrospective study comprised 11 patients (8 males and 3 females) with mean age of 35.8 years ± 1.6 (standard deviation [SD]). The mean volume of NBCA: ethiodized oil (lipiodol) mixture injected by percutaneous direct needle puncture was 0.62 ml ± 0.25 (SD) (range = 0.5–1 ml), and by transcatheter injection, it was 0.62 ml ± 0.37 (SD) (range = 0.3–1.4 ml). Embolization with NBCA was technically and clinically successful in all patients (100%). No recurrence of bleeding or recurrence of pseudoaneurysm/aneurysm was noted in our study. Conclusions: Percutaneous direct needle puncture of visceral artery pseudoaneurysms and NBCA glue injection and transcatheter NBCA injection for embolization of visceral artery pseudoaneurysms and aneurysms are cost-effective techniques that can be used when coil embolization is not feasible or has failed. PMID:28123838

  4. Model Transformation for a System of Systems Dependability Safety Case

    NASA Technical Reports Server (NTRS)

    Murphy, Judy; Driskell, Stephen B.

    2010-01-01

    Software plays an increasingly larger role in all aspects of NASA's science missions. This has been extended to the identification, management and control of faults which affect safety-critical functions and by default, the overall success of the mission. Traditionally, the analysis of fault identification, management and control are hardware based. Due to the increasing complexity of system, there has been a corresponding increase in the complexity in fault management software. The NASA Independent Validation & Verification (IV&V) program is creating processes and procedures to identify, and incorporate safety-critical software requirements along with corresponding software faults so that potential hazards may be mitigated. This Specific to Generic ... A Case for Reuse paper describes the phases of a dependability and safety study which identifies a new, process to create a foundation for reusable assets. These assets support the identification and management of specific software faults and, their transformation from specific to generic software faults. This approach also has applications to other systems outside of the NASA environment. This paper addresses how a mission specific dependability and safety case is being transformed to a generic dependability and safety case which can be reused for any type of space mission with an emphasis on software fault conditions.

  5. Examining the Relationship between Safety Management System Implementation and Safety Culture in Collegiate Flight Schools

    ERIC Educational Resources Information Center

    Robertson, Mike Fuller

    2017-01-01

    Safety Management Systems (SMS) are becoming the industry standard for safety management throughout the aviation industry. As the Federal Aviation Administration (FAA) continues to mandate SMS for different segments, the assessment of an organization's safety culture becomes more important. An SMS can facilitate the development of a strong…

  6. European Workshop Industrical Computer Science Systems approach to design for safety

    NASA Technical Reports Server (NTRS)

    Zalewski, Janusz

    1992-01-01

    This paper presents guidelines on designing systems for safety, developed by the Technical Committee 7 on Reliability and Safety of the European Workshop on Industrial Computer Systems. The focus is on complementing the traditional development process by adding the following four steps: (1) overall safety analysis; (2) analysis of the functional specifications; (3) designing for safety; (4) validation of design. Quantitative assessment of safety is possible by means of a modular questionnaire covering various aspects of the major stages of system development.

  7. Efficacy and safety of corticosteroid injections and other injections for management of tendinopathy: a systematic review of randomised controlled trials.

    PubMed

    Coombes, Brooke K; Bisset, Leanne; Vicenzino, Bill

    2010-11-20

    Few evidence-based treatment guidelines for tendinopathy exist. We undertook a systematic review of randomised trials to establish clinical efficacy and risk of adverse events for treatment by injection. We searched eight databases without language, publication, or date restrictions. We included randomised trials assessing efficacy of one or more peritendinous injections with placebo or non-surgical interventions for tendinopathy, scoring more than 50% on the modified physiotherapy evidence database scale. We undertook meta-analyses with a random-effects model, and estimated relative risk and standardised mean differences (SMDs). The primary outcome of clinical efficacy was protocol-defined pain score in the short term (4 weeks, range 0-12), intermediate term (26 weeks, 13-26), or long term (52 weeks, ≥52). Adverse events were also reported. 3824 trials were identified and 41 met inclusion criteria, providing data for 2672 participants. We showed consistent findings between many high-quality randomised controlled trials that corticosteroid injections reduced pain in the short term compared with other interventions, but this effect was reversed at intermediate and long terms. For example, in pooled analysis of treatment for lateral epicondylalgia, corticosteroid injection had a large effect (defined as SMD>0·8) on reduction of pain compared with no intervention in the short term (SMD 1·44, 95% CI 1·17-1·71, p<0·0001), but no intervention was favoured at intermediate term (-0·40, -0·67 to -0·14, p<0·003) and long term (-0·31, -0·61 to -0·01, p=0·05). Short-term efficacy of corticosteroid injections for rotator-cuff tendinopathy is not clear. Of 991 participants who received corticosteroid injections in studies that reported adverse events, only one (0·1%) had a serious adverse event (tendon rupture). By comparison with placebo, reductions in pain were reported after injections of sodium hyaluronate (short [3·91, 3·54-4·28, p<0·0001], intermediate

  8. The development of an injection system for a compact H(-) cyclotron, the concomitant measurement of injected beam properties and the experimental characterization of the spiral inflector

    NASA Astrophysics Data System (ADS)

    Dehnel, Morgan Patrick

    1998-11-01

    This thesis addresses two major problems. One is of interest to commercial cyclotron manufacturers and the other is of interest to the accelerator physics community. The industrial problem was to produce a compact and modular ion source and injection system for the new TR13 H- cyclotron, which is capable of transporting and injecting a high quality and well matched beam into the cyclotron. The accelerator physics problem was to advance the science of inflector ion optical design, analysis and troubleshooting from the realm of pure simulation to the realm of measurement and experimentation. The industrial problem was solved by designing candidate injection systems in parallel with the TR13 cyclotron design. These systems were fabricated and then experimentally optimized along with the ion source on a 1 MeV test cyclotron. This work resulted in a set of ion source and injection systems with well documented and understood properties. The recommended solution for the TR13 was a cost effective injection system composed of only two axially rotated quadrupole magnets. The accelerator physics problem is the lack of measured cyclotron inflector optical data and beam related properties in the immediate vicinity of a cyclotron inflector. This required the development of an experimental technique to overcome the numerous technical difficulties associated with making measurements near a device as inaccessible as a cyclotron inflector. A diverse assembly of equipment and procedures was required: a well understood injection system, a pinhole collimator for producing beamlets for ray-tracing, a specially configured center region to expose the inflector to view, a system of scintillators in close proximity to the inflector for producing visible beamspots, a TV camera and frame grabber to record images and a set of image analysis and data processing procedures. The results obtained using this technique were: (a) measured constraints on the coefficients of an inflector's transport

  9. Software-Based Safety Systems in Space - Learning from other Domains

    NASA Astrophysics Data System (ADS)

    Klicker, M.; Putzer, H.

    2012-01-01

    Increasing complexity and new emerging capabilities for manned and unmanned missions have been the hallmark of the past decades of space exploration. One of the drivers in this process was the ever increasing use of software and software-intensive systems to implement system functions necessary to the capabilities needed. The course of technological evolution suggests that this development will continue well into the future with a number of challenges for the safety community some of which shall be discussed in this paper. The current state of the art reveals a number of problems with developing and assessing safety critical software which explains the reluctance of the space community to rely on software-based safety measures to mitigate hazards. Among others, usually lack of trustworthy evidence of software integrity in all foreseeable situations and the difficulties to integrate software in the traditional safety analysis framework are cited. Experience from other domains and recent developments in modern software development methodologies and verification techniques are analysed for the suitability for space systems and an avionics architectural framework (see STANAG 4626) for the implementation of safety critical software is proposed. This is shown to create among other features the possibility of numerous degradation modes enhancing overall system safety and interoperability of computerized space systems. It also potentially simplifies international cooperation on a technical level by introducing a higher degree of compatibility. As software safety cannot be tested or argued into a system in hindsight, the development process and especially the architecture chosen are essential to establish safety properties for the software used to implement safety functions. The core of the safety argument revolves around the separation of different functions and software modules from each other by minimal coupling of functions and credible separation mechanisms in the

  10. Software Safety Analysis of a Flight Guidance System

    NASA Technical Reports Server (NTRS)

    Butler, Ricky W. (Technical Monitor); Tribble, Alan C.; Miller, Steven P.; Lempia, David L.

    2004-01-01

    This document summarizes the safety analysis performed on a Flight Guidance System (FGS) requirements model. In particular, the safety properties desired of the FGS model are identified and the presence of the safety properties in the model is formally verified. Chapter 1 provides an introduction to the entire project, while Chapter 2 gives a brief overview of the problem domain, the nature of accidents, model based development, and the four-variable model. Chapter 3 outlines the approach. Chapter 4 presents the results of the traditional safety analysis techniques and illustrates how the hazardous conditions associated with the system trace into specific safety properties. Chapter 5 presents the results of the formal methods analysis technique model checking that was used to verify the presence of the safety properties in the requirements model. Finally, Chapter 6 summarizes the main conclusions of the study, first and foremost that model checking is a very effective verification technique to use on discrete models with reasonable state spaces. Additional supporting details are provided in the appendices.

  11. Fault Injection and Monitoring Capability for a Fault-Tolerant Distributed Computation System

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo; Yates, Amy M.; Malekpour, Mahyar R.

    2010-01-01

    The Configurable Fault-Injection and Monitoring System (CFIMS) is intended for the experimental characterization of effects caused by a variety of adverse conditions on a distributed computation system running flight control applications. A product of research collaboration between NASA Langley Research Center and Old Dominion University, the CFIMS is the main research tool for generating actual fault response data with which to develop and validate analytical performance models and design methodologies for the mitigation of fault effects in distributed flight control systems. Rather than a fixed design solution, the CFIMS is a flexible system that enables the systematic exploration of the problem space and can be adapted to meet the evolving needs of the research. The CFIMS has the capabilities of system-under-test (SUT) functional stimulus generation, fault injection and state monitoring, all of which are supported by a configuration capability for setting up the system as desired for a particular experiment. This report summarizes the work accomplished so far in the development of the CFIMS concept and documents the first design realization.

  12. Safety belt interlock system usage survey

    DOT National Transportation Integrated Search

    1976-08-01

    This research is intended to measure the effectiveness of various use-inducing systems in increasing safety belt usage. Specifically, the objectives are: (1) to determine if the 1975 warning system issued in response to P.L. 93-492 is effective in in...

  13. Rapid and non-destructive identification of water-injected beef samples using multispectral imaging analysis.

    PubMed

    Liu, Jinxia; Cao, Yue; Wang, Qiu; Pan, Wenjuan; Ma, Fei; Liu, Changhong; Chen, Wei; Yang, Jianbo; Zheng, Lei

    2016-01-01

    Water-injected beef has aroused public concern as a major food-safety issue in meat products. In the study, the potential of multispectral imaging analysis in the visible and near-infrared (405-970 nm) regions was evaluated for identifying water-injected beef. A multispectral vision system was used to acquire images of beef injected with up to 21% content of water, and partial least squares regression (PLSR) algorithm was employed to establish prediction model, leading to quantitative estimations of actual water increase with a correlation coefficient (r) of 0.923. Subsequently, an optimized model was achieved by integrating spectral data with feature information extracted from ordinary RGB data, yielding better predictions (r = 0.946). Moreover, the prediction equation was transferred to each pixel within the images for visualizing the distribution of actual water increase. These results demonstrate the capability of multispectral imaging technology as a rapid and non-destructive tool for the identification of water-injected beef. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Centrifugal Compressor Surge Margin Improved With Diffuser Hub Surface Air Injection

    NASA Technical Reports Server (NTRS)

    Skoch, Gary J.

    2002-01-01

    Aerodynamic stability is an important parameter in the design of compressors for aircraft gas turbine engines. Compression system instabilities can cause compressor surge, which may lead to the loss of an aircraft. As a result, engine designers include a margin of safety between the operating line of the engine and the stability limit line of the compressor. The margin of safety is typically referred to as "surge margin." Achieving the highest possible level of surge margin while meeting design point performance objectives is the goal of the compressor designer. However, performance goals often must be compromised in order to achieve adequate levels of surge margin. Techniques to improve surge margin will permit more aggressive compressor designs. Centrifugal compressor surge margin improvement was demonstrated at the NASA Glenn Research Center by injecting air into the vaned diffuser of a 4:1-pressure-ratio centrifugal compressor. Tests were performed using injector nozzles located on the diffuser hub surface of a vane-island diffuser in the vaneless region between the impeller trailing edge and the diffuser-vane leading edge. The nozzle flow path and discharge shape were designed to produce an air stream that remained tangent to the hub surface as it traveled into the diffuser passage. Injector nozzles were located near the leading edge of 23 of the 24 diffuser vanes. One passage did not contain an injector so that instrumentation located in that passage would be preserved. Several orientations of the injected stream relative to the diffuser vane leading edge were tested over a range of injected flow rates. Only steady flow (nonpulsed) air injection was tested. At 100 percent of the design speed, a 15-percent improvement in the baseline surge margin was achieved with a nozzle orientation that produced a jet that was bisected by the diffuser vane leading edge. Other orientations also improved the baseline surge margin. Tests were conducted at speeds below the

  15. Managing Safety and Operations: The Effect of Joint Management System Practices on Safety and Operational Outcomes.

    PubMed

    Tompa, Emile; Robson, Lynda; Sarnocinska-Hart, Anna; Klassen, Robert; Shevchenko, Anton; Sharma, Sharvani; Hogg-Johnson, Sheilah; Amick, Benjamin C; Johnston, David A; Veltri, Anthony; Pagell, Mark

    2016-03-01

    The aim of this study was to determine whether management system practices directed at both occupational health and safety (OHS) and operations (joint management system [JMS] practices) result in better outcomes in both areas than in alternative practices. Separate regressions were estimated for OHS and operational outcomes using data from a survey along with administrative records on injuries and illnesses. Organizations with JMS practices had better operational and safety outcomes than organizations without these practices. They had similar OHS outcomes as those with operations-weak practices, and in some cases, better outcomes than organizations with safety-weak practices. They had similar operational outcomes as those with safety-weak practices, and better outcomes than those with operations-weak practices. Safety and operations appear complementary in organizations with JMS practices in that there is no penalty for either safety or operational outcomes.

  16. Study of a safety margin system for powered-lift STOL aircraft

    NASA Technical Reports Server (NTRS)

    Heffley, R. K.; Jewell, W. F.

    1978-01-01

    A study was conducted to explore the feasibility of a safety margin system for powered-lift aircraft which require a backside piloting technique. The objective of the safety margin system was to present multiple safety margin criteria as a single variable which could be tracked manually or automatically and which could be monitored for the purpose of deriving safety margin status. The study involved a pilot-in-the-loop analysis of several safety margin system concepts and a simulation experiment to evaluate those concepts which showed promise of providing a good solution. A system was ultimately configured which offered reasonable compromises in controllability, status information content, and the ability to regulate the safety margin at some expense of the allowable low speed flight path envelope.

  17. The regulatory system for diabetes mellitus: Modeling rates of glucose infusions and insulin injections

    NASA Astrophysics Data System (ADS)

    Yang, Jin; Tang, Sanyi; Cheke, Robert A.

    2016-08-01

    Novel mathematical models with open and closed-loop control for type 1 or type 2 diabetes mellitus were developed to improve understanding of the glucose-insulin regulatory system. A hybrid impulsive glucose-insulin model with different frequencies of glucose infusions and insulin injections was analyzed, and the existence and uniqueness of the positive periodic solution for type 1 diabetes, which is globally asymptotically stable, was studied analytically. Moreover, permanence of the system for type 2 diabetes was demonstrated which showed that the glucose concentration level is uniformly bounded above and below. To investigate how to prevent hyperinsulinemia and hyperglycemia being caused by this system, we developed a model involving periodic intakes of glucose with insulin injections applied only when the blood glucose level reached a given critical glucose threshold. In addition, our numerical analysis revealed that the period, the frequency and the dose of glucose infusions and insulin injections are crucial for insulin therapies, and the results provide clinical strategies for insulin-administration practices.

  18. Open-type ferry safety system design for using LNG fuel

    NASA Astrophysics Data System (ADS)

    Pagonis, D. N.; Livanos, G.; Theotokatos, G.; Peppa, S.; Themelis, N.

    2016-12-01

    In this feasibility study, we investigate the viability of using Liquefied Natural Gas (LNG) fuel in an open type Ro-Ro passenger ferry and the associated potential challenges with regard to the vessel safety systems. We recommend an appropriate methodology for converting existing ships to run on LNG fuel, discuss all the necessary modifications to the ship's safety systems, and also evaluate the relevant ship evacuation procedures. We outline the basic requirements with which the ship already complies for each safety system and analyze the additional restrictions that must be taken into consideration for the use of LNG fuel. Appropriate actions are recommended. Furthermore, we carry out a hazard identification study. Overall, we clearly demonstrate the technical feasibility of the investigated scenario. Minimal modifications to the ship's safety systems are required to comply with existing safety rules for this specific type of ship.

  19. Patient safety - the role of human factors and systems engineering.

    PubMed

    Carayon, Pascale; Wood, Kenneth E

    2010-01-01

    Patient safety is a global challenge that requires knowledge and skills in multiple areas, including human factors and systems engineering. In this chapter, numerous conceptual approaches and methods for analyzing, preventing and mitigating medical errors are described. Given the complexity of healthcare work systems and processes, we emphasize the need for increasing partnerships between the health sciences and human factors and systems engineering to improve patient safety. Those partnerships will be able to develop and implement the system redesigns that are necessary to improve healthcare work systems and processes for patient safety.

  20. Patient Safety: The Role of Human Factors and Systems Engineering

    PubMed Central

    Carayon, Pascale; Wood, Kenneth E.

    2011-01-01

    Patient safety is a global challenge that requires knowledge and skills in multiple areas, including human factors and systems engineering. In this chapter, numerous conceptual approaches and methods for analyzing, preventing and mitigating medical errors are described. Given the complexity of healthcare work systems and processes, we emphasize the need for increasing partnerships between the health sciences and human factors and systems engineering to improve patient safety. Those partnerships will be able to develop and implement the system redesigns that are necessary to improve healthcare work systems and processes for patient safety. PMID:20543237

  1. Photovoltaic system criteria documents. Volume 5: Safety criteria for photovoltaic applications

    NASA Technical Reports Server (NTRS)

    Koenig, John C.; Billitti, Joseph W.; Tallon, John M.

    1979-01-01

    Methodology is described for determining potential safety hazards involved in the construction and operation of photovoltaic power systems and provides guidelines for the implementation of safety considerations in the specification, design and operation of photovoltaic systems. Safety verification procedures for use in solar photovoltaic systems are established.

  2. Bacterial diversity in water injection systems of Brazilian offshore oil platforms.

    PubMed

    Korenblum, Elisa; Valoni, Erika; Penna, Mônica; Seldin, Lucy

    2010-01-01

    Biogenic souring and microbial-influenced corrosion is a common scenario in water-flooded petroleum reservoirs. Water injection systems are continuously treated to control bacterial contamination, but some bacteria that cause souring and corrosion can persist even after different treatments have been applied. Our aim was to increase our knowledge of the bacterial communities that persist in the water injection systems of three offshore oil platforms in Brazil. To achieve this goal, we used a culture-independent molecular approach (16S ribosomal RNA gene clone libraries) to analyze seawater samples that had been subjected to different treatments. Phylogenetic analyses revealed that the bacterial communities from the different platforms were taxonomically different. A predominance of bacterial clones affiliated with Gammaproteobacteria, mostly belonging to the genus Marinobacter (60.7%), were observed in the platform A samples. Clones from platform B were mainly related to the genera Colwellia (37.9%) and Achromobacter (24.6%), whereas clones obtained from platform C were all related to unclassified bacteria. Canonical correspondence analyses showed that different treatments such as chlorination, deoxygenation, and biocide addition did not significantly influence the bacterial diversity in the platforms studied. Our results demonstrated that the injection water used in secondary oil recovery procedures contained potentially hazardous bacteria, which may ultimately cause souring and corrosion.

  3. Fuel system for rotary distributor fuel injection pump

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klopfer, K.H.; Kelly, W.W.

    1993-06-01

    In a fuel injection pump having a drive shaft, a pump rotor driven by the drive shaft, reciprocating pumping means with periodic intake and pumping strokes to periodically receive an intake charge of fuel and deliver fuel at high pressure for fuel injection is described; a distributor head with a plurality of angularly spaced distributor outlets, the pump rotor providing a distributor rotor with a distributor port connected to the pumping means, the distributor rotor being rotatably mounted in the distributor head for sequential registration of the distributor port with the distributor outlets for distributing said high pressure delivery ofmore » fuel thereto; a fuel system for supplying fuel to the pumping means, having an end chamber at one end of the pump rotor and a fuel supply pump driven by the drive shaft and having an inlet and outlet, the supply pump outlet being connected to the end chamber for supplying fuel thereto, and a pressure regulator for regulating the fuel pressure in the end chamber; and a control valve connected between the pumping means and the end chamber and selectively opened during the intake strokes to supply fuel to the pumping means from the end chamber and during the pumping strokes to spill fuel from the pumping means into the end chamber to terminate said high pressure delivery of fuel; the improvement wherein the fuel system comprises a fuel return passage connected in series with the end chamber downstream thereof, wherein the pressure regulator is mounted in the return passage for regulating the upstream fuel pressure, including the upstream fuel pressure within the end chamber, and is connected for conducting excess fuel for return to the supply pump inlet, and wherein the supply pump is driven by the drive shaft to supply fuel at a rate exceeding the rate of said high pressure delivery of fuel for fuel injection and to provide excess fuel flow continuously through the end chamber and return passage to the pressure regulator.« less

  4. Intra-articular corticoid injection induces circulating glucocorticoid bioactivity and systemic immune activation in juvenile idiopathic arthritis.

    PubMed

    Rintamäki, H; Tamm, K; Vaarala, O; Sidoroff, M; Honkanen, V; Raivio, T; Jänne, Oa; Kolho, K-L

    2011-01-01

    To study the systemic effects of intra-articular (IA) glucocorticoid (GC) injections in juvenile idiopathic arthritis (JIA). The study group comprised 21 JIA patients being treated with IA methylprednisolone [MP (n = 15) or MP plus triamcinolone hexacetonide (THA) (n = 6)] prescribed on clinical indications. The systemic effect of MP was assessed by measuring circulating glucocorticoid bioactivity (GBA) with a recombinant cell transactivation assay 7 and 24 h after the IA injections, and after 2 months. The systemic immunological responses were studied with a novel assay for testing patient serum-induced changes in the secretion of interferon (IFN)-γ and interleukin (IL)-5 from target cells. Administration of IA GC induced serum GBA (p = 0.001) and suppressed circulating cortisol levels (p = 0.002) 7 h after the injection. Serum withdrawn 24 h after the IA injection induced less IL-5 secretion from mitogen-activated target cells when compared with pre-treatment sera (p = 0.036). This decrease in target cell T helper (Th)2 response (IL-5) was MP dose related (r = -0.550, p = 0.018). High IL-5 secretion from target cells prior to the IA injections was associated with good clinical outcome at 2 months, seen as a low number of active (p = 0.044) and restricted joints (p = 0.049). IA GC injections have systemic effects that are reflected in the serum as an immediate elevation of GBA, a decrease of endogenous cortisol as well as a suppressive effect of patient serum on target cell IL-5 secretion. These systemic effects may play a role in the attenuation of disease activity.

  5. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1976-01-01

    During the second quarter of the Aviation Safety Reporting System (ASRS) operation, 1,497 reports were received from pilots, controllers, and others in the national aviation system. Details of the administration and results of the program to date are presented. Examples of alert bulletins disseminated to the aviation community are presented together with responses to those bulletins. Several reports received by ASRS are also presented to illustrate the diversity of topics covered by reports to the system.

  6. Systemic morphine blocks the seizures induced by intracerebroventricular (i.c.v.) injections of opiates and opioid peptides.

    PubMed

    Urca, G; Frenk, H

    1982-08-19

    Intracerebroventricular (i.c.v.) injections of the endorphins and of morphine in rats produce highly characteristic, naloxone sensitive, electrographic seizures. In contrast, systemic injections of morphine have been shown to exert a marked anticonvulsant effect. The present study demonstrates that systemic morphine pretreatment can prevent the occurrence of electrographic seizures injected by i.c.v. morphine, Leu-enkephalin and beta-endorphin and that the anti-epileptic effect of morphine can be reversed by naloxone. Male albino rats, previously prepared for chronic i.c.v. injections and EEG recordings, were pretreated with 0--100 mg/kg of intraperitoneal (i.p.) morphine. Thirty five minutes later morphine (520 nmol), Leu-enkephalin (80 nmol) or beta-endorphin (5 nmol) were injected i.c.v. Pretreatment with i.p. morphine blocked the occurrence of seizures induced by morphine and both endogenous opioids. Lower doses of systemic morphine (50 mg/kg) were necessary to block i.c.v. morphine seizures than the dose (100 mg/kg) necessary to block seizures induced by i.c.v. Leu-enkephalin and beta-endorphin. Naloxone (1 mg/kg) administered 25 min following 50 mg/kg of i.p. morphine and preceding the injections of i.c.v. morphine reversed the antiepileptic effect of systemic morphine. These results demonstrate the possible existence of two opiate sensitive systems, one with excitatory-epileptogenic effects and the other possessing inhibitory-antiepileptic properties. The possible relationship between these findings and the known heterogeneity of opiate receptors and opiate actions is discussed.

  7. Phase and flow behavior of mixed gas hydrate systems during gas injection

    NASA Astrophysics Data System (ADS)

    Darnell, K.; Flemings, P. B.; DiCarlo, D. A.

    2017-12-01

    We present one-dimensional, multi-phase flow model results for injections of carbon dioxide and nitrogen mixtures, or flue gas, into methane hydrate bearing reservoirs. Our flow model is coupled to a thermodynamic simulator that predicts phase stabilities as a function of composition, so multiple phases can appear, disappear, or change composition as the injection invades the reservoir. We show that the coupling of multi-phase fluid flow with phase behavior causes preferential phase fractionation in which each component flows through the system at different speeds and in different phases. We further demonstrate that phase and flow behavior within the reservoir are driven by hydrate stability of each individual component in addition to the hydrate stability of the injection composition. For example, if carbon dioxide and nitrogen are both individually hydrate stable at the reservoir P-T conditions, then any injection composition will convert all available water into hydrate and plug the reservoir. In contrast, if only carbon dioxide is hydrate stable at the reservoir P-T conditions, then nitrogen preferentially stays in the gaseous phase, while the carbon dioxide partitions into the hydrate and liquid water phases. For all injections of this type, methane originally held in hydrate is released by dissociation into the nitrogen-rich gaseous phase. The net consequence is that a gas phase composed of nitrogen and methane propagates through the reservoir in a fast-moving front. A slower-moving front lags behind where carbon dioxide and nitrogen form a mixed hydrate, but methane is absent due to dissociation-induced methane stripping from the first, fast-moving front. The entire composition path traces through the phase space as the flow develops with each front moving at different, constant velocities. This behavior is qualitatively similar to the dynamics present in enhanced oil recovery or enhanced coalbed methane recovery. These results explain why the inclusion of

  8. Intravitreal, Subretinal, and Suprachoroidal Injections: Evolution of Microneedles for Drug Delivery.

    PubMed

    Hartman, Rachel R; Kompella, Uday B

    Even though the very thought of an injection into the eye may be frightening, an estimated 6 million intravitreal (IVT) injections were made in the USA during 2016. With the introduction of new therapeutic agents, this number is expected to increase. In addition, drug products that are injectable in ocular compartments other than the vitreous humor are expected to enter the back of the eye market in the not so distant future. Besides the IVT route, some of the most actively investigated routes of invasive administration to the eye include periocular, subretinal, and suprachoroidal (SC) routes. While clinical efficacy is the driving force behind new injectable drug product development for the eye, safety is also being improved with time. In the case of IVT injections, the procedural guidelines have evolved over the years to improve patient comfort and reduce injection-related injury and infection. Similar advances are anticipated for other routes of administration of injectable products to the eye. In addition to procedural improvements, the design of needles, particularly those with smaller diameters, length, and controlled bevel angles are expected to improve overall safety and acceptance of injected ophthalmic drug products. A key development in this area is the introduction of microneedles of a length less than a millimeter that can target the SC space. In the future, needles with smaller diameters and lengths, potentially approaching nanodimensions, are expected to revolutionize ophthalmic disease management.

  9. Epistemic Questions and Answers for Software System Safety

    NASA Technical Reports Server (NTRS)

    Holloway, C. M.; Johnson, Chris W.

    2010-01-01

    System safety is primarily concerned with epistemic questions, that is, questions concerning knowledge and the degree of confidence that can be placed in that knowledge. For systems with which human experience is long, such as roads, bridges, and mechanical devices, knowledge about what is required to make the systems safe is deep and detailed. High confidence can be placed in the validity of that knowledge. For other systems, however, with which human experience is comparatively short, such as those that rely in part or in whole on software, knowledge about what is required to ensure safety tends to be shallow and general. The confidence that can be placed in the validity of that knowledge is consequently low. In a previous paper, we enumerated a collection of foundational epistemic questions concerning software system safety. In this paper, we review and refine the questions, discuss some difficulties that attend to answering the questions today, and speculate on possible research to improve the situation.

  10. 75 FR 68224 - Safety Management Systems for Part 121 Certificate Holders

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-05

    ... the general framework for an organization-wide safety management approach to air carrier operations... System? An SMS is an organization-wide approach to managing safety risk and assuring the effectiveness of... under 14 CFR part 121 to develop and implement a safety management system (SMS) to improve the safety of...

  11. A review of wiring system safety in space power systems

    NASA Technical Reports Server (NTRS)

    Stavnes, Mark W.; Hammoud, Ahmad N.

    1993-01-01

    Wiring system failures have resulted from arc propagation in the wiring harnesses of current aerospace vehicles. These failures occur when the insulation becomes conductive upon the initiation of an arc. In some cases, the conductive path of the carbon arc track displays a high enough resistance such that the current is limited, and therefore may be difficult to detect using conventional circuit protection. Often, such wiring failures are not simply the result of insulation failure, but are due to a combination of wiring system factors. Inadequate circuit protection, unforgiving system designs, and careless maintenance procedures can contribute to a wiring system failure. This paper approaches the problem with respect to the overall wiring system, in order to determine what steps can be taken to improve the reliability, maintainability, and safety of space power systems. Power system technologies, system designs, and maintenance procedures which have led to past wiring system failures will be discussed. New technologies, design processes, and management techniques which may lead to improved wiring system safety will be introduced.

  12. Systems Analysis of NASA Aviation Safety Program: Final Report

    NASA Technical Reports Server (NTRS)

    Jones, Sharon M.; Reveley, Mary S.; Withrow, Colleen A.; Evans, Joni K.; Barr, Lawrence; Leone, Karen

    2013-01-01

    A three-month study (February to April 2010) of the NASA Aviation Safety (AvSafe) program was conducted. This study comprised three components: (1) a statistical analysis of currently available civilian subsonic aircraft data from the National Transportation Safety Board (NTSB), the Federal Aviation Administration (FAA), and the Aviation Safety Information Analysis and Sharing (ASIAS) system to identify any significant or overlooked aviation safety issues; (2) a high-level qualitative identification of future safety risks, with an assessment of the potential impact of the NASA AvSafe research on the National Airspace System (NAS) based on these risks; and (3) a detailed, top-down analysis of the NASA AvSafe program using an established and peer-reviewed systems analysis methodology. The statistical analysis identified the top aviation "tall poles" based on NTSB accident and FAA incident data from 1997 to 2006. A separate examination of medical helicopter accidents in the United States was also conducted. Multiple external sources were used to develop a compilation of ten "tall poles" in future safety issues/risks. The top-down analysis of the AvSafe was conducted by using a modification of the Gibson methodology. Of the 17 challenging safety issues that were identified, 11 were directly addressed by the AvSafe program research portfolio.

  13. Development of an automated flow injection analysis system for determination of phosphate in nutrient solutions.

    PubMed

    Karadağ, Sevinç; Görüşük, Emine M; Çetinkaya, Ebru; Deveci, Seda; Dönmez, Koray B; Uncuoğlu, Emre; Doğu, Mustafa

    2018-01-25

    A fully automated flow injection analysis (FIA) system was developed for determination of phosphate ion in nutrient solutions. This newly developed FIA system is a portable, rapid and sensitive measuring instrument that allows on-line analysis and monitoring of phosphate ion concentration in nutrient solutions. The molybdenum blue method, which is widely used in FIA phosphate analysis, was adapted to the developed FIA system. The method is based on the formation of ammonium Mo(VI) ion by reaction of ammonium molybdate with the phosphate ion present in the medium. The Mo(VI) ion then reacts with ascorbic acid and is reduced to the spectrometrically measurable Mo(V) ion. New software specific for flow analysis was developed in the LabVIEW development environment to control all the components of the FIA system. The important factors affecting the analytical signal were identified as reagent flow rate, injection volume and post-injection flow path length, and they were optimized using Box-Behnken experimental design and response surface methodology. The optimum point for the maximum analytical signal was calculated as 0.50 mL min -1 reagent flow rate, 100 µL sample injection volume and 60 cm post-injection flow path length. The proposed FIA system had a sampling frequency of 100 samples per hour over a linear working range of 3-100 mg L -1 (R 2  = 0.9995). The relative standard deviation (RSD) was 1.09% and the limit of detection (LOD) was 0.34 mg L -1 . Various nutrient solutions from a tomato-growing hydroponic greenhouse were analyzed with the developed FIA system and the results were found to be in good agreement with vanadomolybdate chemical method findings. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  14. Research on public participant urban infrastructure safety monitoring system using smartphone

    NASA Astrophysics Data System (ADS)

    Zhao, Xuefeng; Wang, Niannian; Ou, Jinping; Yu, Yan; Li, Mingchu

    2017-04-01

    Currently more and more people concerned about the safety of major public security. Public participant urban infrastructure safety monitoring and investigation has become a trend in the era of big data. In this paper, public participant urban infrastructure safety protection system based on smart phones is proposed. The system makes it possible to public participant disaster data collection, monitoring and emergency evaluation in the field of disaster prevention and mitigation. Function of the system is to monitor the structural acceleration, angle and other vibration information, and extract structural deformation and implement disaster emergency communications based on smartphone without network. The monitoring data is uploaded to the website to create urban safety information database. Then the system supports big data analysis processing, the structure safety assessment and city safety early warning.

  15. System for controlling child safety seat environment

    NASA Technical Reports Server (NTRS)

    Elrod, Susan V. (Inventor); Dabney, Richard W. (Inventor)

    2008-01-01

    A system is provided to control the environment experienced by a child in a child safety seat. Each of a plurality of thermoelectric elements is individually controllable to be one of heated and cooled relative to an ambient temperature. A first portion of the thermoelectric elements are positioned on the child safety seat such that a child sitting therein is positioned thereover. A ventilator coupled to the child safety seat moves air past a second portion of the thermoelectric elements and filters the air moved therepast. One or more jets coupled to the ventilator receive the filtered air. Each jet is coupled to the child safety seat and can be positioned to direct the heated/cooled filtered air to the vicinity of the head of the child sitting in the child safety seat.

  16. CSHM: Web-based safety and health monitoring system for construction management.

    PubMed

    Cheung, Sai On; Cheung, Kevin K W; Suen, Henry C H

    2004-01-01

    This paper describes a web-based system for monitoring and assessing construction safety and health performance, entitled the Construction Safety and Health Monitoring (CSHM) system. The design and development of CSHM is an integration of internet and database systems, with the intent to create a total automated safety and health management tool. A list of safety and health performance parameters was devised for the management of safety and health in construction. A conceptual framework of the four key components of CSHM is presented: (a) Web-based Interface (templates); (b) Knowledge Base; (c) Output Data; and (d) Benchmark Group. The combined effect of these components results in a system that enables speedy performance assessment of safety and health activities on construction sites. With the CSHM's built-in functions, important management decisions can theoretically be made and corrective actions can be taken before potential hazards turn into fatal or injurious occupational accidents. As such, the CSHM system will accelerate the monitoring and assessing of performance safety and health management tasks.

  17. Safety management of a complex R&D ground operating system

    NASA Technical Reports Server (NTRS)

    Connors, J. F.; Maurer, R. A.

    1975-01-01

    A perspective on safety program management has been developed for a complex R&D operating system, such as the NASA-Lewis Research Center. Using a systems approach, hazardous operations are subjected to third-party reviews by designated area safety committees and are maintained under safety permit controls. To insure personnel alertness, emergency containment forces and employees are trained in dry-run emergency simulation exercises. The keys to real safety effectiveness are top management support and visibility of residual risks.

  18. Safety system for child pillion riders of underbone motorcycles in Malaysia.

    PubMed

    Sivasankar, S; Karmegam, K; Bahri, M T Shamsul; Naeini, H Sadeghi; Kulanthayan, S

    2014-01-01

    Motorcycles are a common mode of transport for most Malaysians. Underbone motorcycles are one of the most common types of motorcycle used in Malaysia due to their affordable price and ease of use, especially in heavy traffic in the major cities. In Malaysia, it is common to see a young or child pillion rider clinging on to an adult at the front of the motorcycle. One of the main issues facing young pillion riders is that their safety is often not taken into account when they are riding on a motorcycle. This article reviews the legally available systems in child safety for underbone motorcycles in Malaysia while putting forth the need for a safety system for child pillion riders. Various databases were searched for underbone motorcycle safety systems, related legislation, motorcycle accident data, and types of injuries and these were reviewed to put forth the need for a new safety system. In motorcycle-related accidents, children usually sustain lower limb injuries, which could temporarily or permanently inhibit the child's movements. Accident statistics in Malaysia, especially those involving motorcycles, reflect a pressing need for a reduction in the number of accidents. In Malaysia, the legislation does not go beyond the mandatory use of safety helmets for young pillion users. There is a pressing need for another safety system or mechanism(s) for young pillion riders of underbone motorcycles. Enforcement of laws to enforce the usage of passive safety systems such as helmets and protective gear is difficult in underdeveloped and developing countries. The intervention of new technology is inevitable. Therefore, this article highlights the need for a new safety backrest system for child pillion riders to ensure their safety.

  19. 75 FR 1274 - Implantation or Injectable Dosage Form New Animal Drugs; Hyaluronate Sodium

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-11

    ... safety warning for use of hyaluronate sodium injectable solution in horses. DATES: This rule is effective... human food safety warning on product labeling. The supplemental NADA is approved as of December 11, 2009...

  20. Efficacy and Safety of Injectable Robenacoxib for the Treatment of Pain Associated With Soft Tissue Surgery in Dogs.

    PubMed

    Friton, G; Thompson, C; Karadzovska, D; King, S; King, J N

    2017-05-01

    Nonsteroidal anti-inflammatory drugs (NSAIDs) are used routinely to control pain and inflammation after surgery in dogs. Robenacoxib is a cyclooxygenase-2 selective NSAID. Assess the clinical efficacy and safety of an injectable formulation of robenacoxib in dogs undergoing surgery. Three hundred and seventeen client-owned dogs (N = 159 robenacoxib or N = 158 placebo). In this prospective, multicenter, randomized, masked, placebo-controlled, parallel-group study, dogs received a SC injection of either robenacoxib, at a target dose of 2.0 mg/kg, or placebo once prior to surgery and for 2 additional days postoperatively. Pain assessments were performed using the short form of the Glasgow Composite Measure Pain Scale (CMPS-SF). The primary efficacy variable was treatment success/failure, with failure defined as the need for rescue therapy to control pain or withdrawal of the dog from the study due to an adverse event. Significantly (P = .006) more dogs administered robenacoxib were considered treatment successes (108 of 151, 73.7%) compared to dogs given placebo (85 of 152, 58.1%). Total pain scores (P < .01), pain at the surgery sites (response to touch, P < .01), and posture/activity (P < .05) were significantly improved at 3, 5, and 8 hours postextubation in dogs receiving robenacoxib versus placebo. Robenacoxib administered by SC injection prior to surgery and for 2 additional days postoperatively was effective and well tolerated in the control of postoperative pain and inflammation associated with soft tissue surgery in dogs. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  1. New Automated System Available for Reporting Safety Concerns | Poster

    Cancer.gov

    A new system has been developed for reporting safety issues in the workplace. The Environment, Health, and Safety’s (EHS’) Safety Inspection and Issue Management System (SIIMS) is an online resource where any employee can report a problem or issue, said Siobhan Tierney, program manager at EHS.

  2. Research on the technology of detecting the SQL injection attack and non-intrusive prevention in WEB system

    NASA Astrophysics Data System (ADS)

    Hu, Haibin

    2017-05-01

    Among numerous WEB security issues, SQL injection is the most notable and dangerous. In this study, characteristics and procedures of SQL injection are analyzed, and the method for detecting the SQL injection attack is illustrated. The defense resistance and remedy model of SQL injection attack is established from the perspective of non-intrusive SQL injection attack and defense. Moreover, the ability of resisting the SQL injection attack of the server has been comprehensively improved through the security strategies on operation system, IIS and database, etc.. Corresponding codes are realized. The method is well applied in the actual projects.

  3. Safety, pharmacokinetics, and pharmacodynamics of S-(-)-pantoprazole sodium injections after single and multiple intravenous doses in healthy Chinese subjects.

    PubMed

    Jiao, Hui-Wen; Sun, Lu-Ning; Li, Yue-Qi; Yu, Lei; Zhang, Hong-Wen; Wang, Mei-Feng; Yu, Li-Yuan; Yuan, Zi-Qing-Yun; Xie, Li-Jun; Chen, Juan; Meng, Ling; Zhang, Xue-Hui; Wang, Yong-Qing

    2018-03-01

    The objective of this study was to evaluate the safety, pharmacokinetics, and pharmacodynamics of S-(-)-pantoprazole (PPZ) sodium injections following single and multiple intravenous doses in healthy Chinese subjects. The dosage groups were set as followed: 20 mg of single and multiple intravenous administration of S-(-)-PPZ, 40 mg of single and multiple intravenous administration of S-(-)-PPZ or pantoprazole, and 80 mg of single dosage group of S-(-)-PPZ. Subjects were sampled for pharmacokinetic analysis and were monitored for 24-h intragastric pH prior to and 48-h intragastric pH after administration for the pharmacodynamic study. The pharmacokinetic and pharmacodynamic parameters were compared between S-(-)-PPZ and PPZ. Safety was evaluated on the basis of adverse events, vital signs, laboratory tests, and physical examination. All adverse events were mild and of limited duration. Maximum plasma concentration and area under the concentration-time curve for S-(-)-PPZ were dose proportional over the range of 20-80 mg following a single intravenous administration. Elimination rate constant and half-life observed statistical difference from a single dose to multiple doses in 40 mg of S-(-)-PPZ groups. After administration of a single dose, the mean 24-h intragastric pH value was observed higher in 80-mg group than in 40- and 20-mg groups. Slightly increase of intragastric pH was found after a single dose of 40 mg S-(-)-PPZ than 40 mg PPZ; however, the differences were not statistically significant. Twice daily of 40 mg S-(-)-PPZ sodium injections is effective in achieving satisfying acid inhibition. Compared with plasma R-(+)-PPZ levels, most subjects presented more potent and prolonged suppression of gastric acid of S-(-)-PPZ, while a few subjects showed faster metabolic rate of S-(-)-PPZ in vivo.

  4. Manned space flight nuclear system safety. Voluem 5: Nuclear system safety guidelines. Part 2: Space shuttle/nuclear payloads safety

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The design and operations guidelines and requirements developed in the study of space shuttle nuclear system transportation are presented. Guidelines and requirements are presented for the shuttle, nuclear payloads (reactor, isotope-Brayton and small isotope sources), ground support systems and facilities. Cross indices and references are provided which relate guidelines to each other, and to substantiating data in other volumes. The guidelines are intended for the implementation of nuclear safety related design and operational considerations in future space programs.

  5. Comparative Study of Efficacy and Safety of Botulinum Toxin a Injections and Subcutaneous Curettage in the Treatment of Axillary Hyperhidrosis

    PubMed Central

    Budamakuntla, Leelavathy; Loganathan, Eswari; George, Anju; Revanth, BN; Sankeerth, V; Sarvjnamurthy, Sacchidananda Aradhya

    2017-01-01

    Background: Primary focal axillary hyperhidrosis is a chronic distressing disorder affecting both the sexes. When the condition is refractory to conservative management, we should go for more promising therapies like intradermal botulinum toxin A (BtxA) injections in the axilla, and surgical therapies like subcutaneous curettage of sweat glands. Aims and Objectives: The aim of this study is to compare the efficacy, safety and duration of action of intradermal BtxA injections in one axilla and subcutaneous curettage of sweat glands in the other axilla of the same patient with axillary hyperhidrosis. Materials and Methods: Twenty patients (40 axillae) received intradermal BtxA injections on the right side (20 axillae) and underwent tumescent subcutaneous curettage of sweat glands on the left side (20 axillae). Sweat production rate was measured using gravimetry analyses at baseline and at 3 months after the procedure. Subjective analyses were done using hyperhidrosis disease severity scale (HDSS) score at baseline, at 3rd and 6th month after the procedure. Results: At 3 months post-treatment, the resting sweat rate in the toxin group improved by 80.32% versus 79.79% in the subcutaneous curettage method (P = 0.21). Exercise-induced sweat rate in the toxin group improved by 88.76% versus 88.8% in the subcutaneous curettage group (P = 0.9). There was a significant difference in the HDSS score after treatment with both the modalities. There were no adverse events with BtxA treatment compared to very minor adverse events with the surgical method. Conclusion: Both intradermal BtxA injections and tumescent subcutaneous curettage of sweat glands had a significant decrease in the sweat rates with no significant difference between the two modalities. Hence, in resource poor settings where affordability of BtxA injection is a constraint, subcutaneous curettage of sweat glands can be preferred which has been found equally effective with no or minimal adverse events. PMID

  6. Electronic clinical safety reporting system: a benefits evaluation.

    PubMed

    Elliott, Pamela; Martin, Desmond; Neville, Doreen

    2014-06-11

    Eastern Health, a large health care organization in Newfoundland and Labrador (NL), started a staged implementation of an electronic occurrence reporting system (used interchangeably with "clinical safety reporting system") in 2008, completing Phase One in 2009. The electronic clinical safety reporting system (CSRS) was designed to replace a paper-based system. The CSRS involves reporting on occurrences such as falls, safety/security issues, medication errors, treatment and procedural mishaps, medical equipment malfunctions, and close calls. The electronic system was purchased from a vendor in the United Kingdom that had implemented the system in the United Kingdom and other places, such as British Columbia. The main objective of the new system was to improve the reporting process with the goal of improving clinical safety. The project was funded jointly by Eastern Health and Canada Health Infoway. The objectives of the evaluation were to: (1) assess the CSRS on achieving its stated objectives (particularly, the benefits realized and lessons learned), and (2) identify contributions, if any, that can be made to the emerging field of electronic clinical safety reporting. The evaluation involved mixed methods, including extensive stakeholder participation, pre/post comparative study design, and triangulation of data where possible. The data were collected from several sources, such as project documentation, occurrence reporting records, stakeholder workshops, surveys, focus groups, and key informant interviews. The findings provided evidence that frontline staff and managers support the CSRS, identifying both benefits and areas for improvement. Many benefits were realized, such as increases in the number of occurrences reported, in occurrences reported within 48 hours, in occurrences reported by staff other than registered nurses, in close calls reported, and improved timelines for notification. There was also user satisfaction with the tool regarding ease of use

  7. Liquid and gelled sprays for mixing hypergolic propellants using an impinging jet injection system

    NASA Astrophysics Data System (ADS)

    James, Mark D.

    The characteristics of sprays produced by liquid rocket injectors are important in understanding rocket engine ignition and performance. The includes, but is not limited to, drop size distribution, spray density, drop velocity, oscillations in the spray, uniformity of mixing between propellants, and the spatial distribution of drops. Hypergolic ignition and the associated ignition delay times are also important features in rocket engines, providing high reliability and simplicity of the ignition event. The ignition delay time is closely related to the level and speed of mixing between a hypergolic fuel and oxidizer, which makes the injection method and conditions crucial in determining the ignition performance. Although mixing and ignition of liquid hypergolic propellants has been studied for many years, the processes for injection, mixing, and ignition of gelled hypergolic propellants are less understood. Gelled propellants are currently under investigation for use in rocket injectors to combine the advantages of solid and liquid propellants, although not without their own difficulties. A review of hypergolic ignition has been conducted for selected propellants, and methods for achieving ignition have been established. This research is focused on ignition using the liquid drop-on-drop method, as well as the doublet impinging jet injector. The events leading up to ignition, known as pre-ignition stage are discussed. An understanding of desirable ignition and combustion performance requires a study of the effects of injection, temperature, and ambient pressure conditions. A review of unlike-doublet impinging jet injection mixing has also been conducted. This includes mixing factors in reactive and non-reactive sprays. Important mixing factors include jet momentum, jet diameter and length, impingement angle, mass distribution, and injector configuration. An impinging jet injection system is presented using an electro-mechanically driven piston for injecting liquid

  8. [On relationship of acupoint-injection with injury of peripheral nerves].

    PubMed

    Guo, Chang-Qing; Chen, You-Nan

    2007-04-01

    To provide basis for strengthening safety of acupoint-injection and increasing clinical therapeutic effect. Analyze and study on the relative articles from the databank of whole articles of Chinese periodicals of CNKI by information retrieval with computer, with acupoint-injection, nerve injury as key words. Most of clinical reports focus on acupoint-injection for treatment of nervous injury induced by trauma and birth injury. The studies indicate that the injuries of the peripheral nerves induced by acupoint-injection can be divided into 3 grades and the injury mechanisms can be divided into 3 classifications. The injuring causes include improper posture of the patients, improper angle and depth of injection and improper medicine selection. Acupoint-injection can be applied more widely as soon as the accomplishment of the standardization of operation.

  9. Intraseptal anesthesia: a review of a relevant injection technique.

    PubMed

    Woodmansey, Karl

    2005-01-01

    Although overshadowed by intraosseous anesthesia and the periodontal ligament injection, intraseptal anesthesia remains a useful local anesthesia technique for general dentists. Intraseptal anesthesia can be employed with safety and efficacy as an alternative to conventional local infiltration or regional nerve block injections. It also can serve as an adjunctive technique when conventional techniques fail to achieve adequate local anesthesia. This article reviews the intraseptal anesthesia technique, including its indications and limitations.

  10. Safety Metrics for Human-Computer Controlled Systems

    NASA Technical Reports Server (NTRS)

    Leveson, Nancy G; Hatanaka, Iwao

    2000-01-01

    The rapid growth of computer technology and innovation has played a significant role in the rise of computer automation of human tasks in modem production systems across all industries. Although the rationale for automation has been to eliminate "human error" or to relieve humans from manual repetitive tasks, various computer-related hazards and accidents have emerged as a direct result of increased system complexity attributed to computer automation. The risk assessment techniques utilized for electromechanical systems are not suitable for today's software-intensive systems or complex human-computer controlled systems.This thesis will propose a new systemic model-based framework for analyzing risk in safety-critical systems where both computers and humans are controlling safety-critical functions. A new systems accident model will be developed based upon modem systems theory and human cognitive processes to better characterize system accidents, the role of human operators, and the influence of software in its direct control of significant system functions Better risk assessments will then be achievable through the application of this new framework to complex human-computer controlled systems.

  11. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  12. Effects of organizational safety on employees' proactivity safety behaviors and occupational health and safety management systems in Chinese high-risk small-scale enterprises.

    PubMed

    Mei, Qiang; Wang, Qiwei; Liu, Suxia; Zhou, Qiaomei; Zhang, Jingjing

    2018-06-07

    Based on the characteristics of small-scale enterprises, the improvement of occupational health and safety management systems (OHS MS) needs an effective intervention. This study proposed a structural equation model and examined the relationships of perceived organization support for safety (POSS), person-organization safety fit (POSF) and proactivity safety behaviors with safety management, safety procedures and safety hazards identification. Data were collected from 503 employees of 105 Chinese high-risk small-scale enterprises over 6 months. The results showed that both POSS and POSF were positively related to improvement in safety management, safety procedures and safety hazards identification through proactivity safety behaviors. Our findings provide a new perspective on organizational safety for improving OHS MS for small-scale enterprises and extend the application of proactivity safety behaviors.

  13. Patient Safety Learning Systems: A Systematic Review and Qualitative Synthesis.

    PubMed

    2017-01-01

    A patient safety learning system (sometimes called a critical incident reporting system) refers to structured reporting, collation, and analysis of critical incidents. To inform a provincial working group's recommendations for an Ontario Patient Safety Event Learning System, a systematic review was undertaken to determine design features that would optimize its adoption into the health care system and would inform implementation strategies. The objective of this review was to address two research questions: (a) what are the barriers to and facilitators of successful adoption of a patient safety learning system reported by health professionals and (b) what design components maximize successful adoption and implementation? To answer the first question, we used a published systematic review. To answer the second question, we used scoping study methodology. Common barriers reported in the literature by health care professionals included fear of blame, legal penalties, the perception that incident reporting does not improve patient safety, lack of organizational support, inadequate feedback, lack of knowledge about incident reporting systems, and lack of understanding about what constitutes an error. Common facilitators included a non-accusatory environment, the perception that incident reporting improves safety, clarification of the route of reporting and of how the system uses reports, enhanced feedback, role models (such as managers) using and promoting reporting, legislated protection of those who report, ability to report anonymously, education and training opportunities, and clear guidelines on what to report. Components of a patient safety learning system that increased successful adoption and implementation were emphasis on a blame-free culture that encourages reporting and learning, clear guidelines on how and what to report, making sure the system is user-friendly, organizational development support for data analysis to generate meaningful learning outcomes

  14. Development and evaluation of injectable nanosized drug delivery systems for apigenin.

    PubMed

    Karim, Reatul; Palazzo, Claudio; Laloy, Julie; Delvigne, Anne-Sophie; Vanslambrouck, Stéphanie; Jerome, Christine; Lepeltier, Elise; Orange, Francois; Dogne, Jean-Michel; Evrard, Brigitte; Passirani, Catherine; Piel, Géraldine

    2017-11-05

    The purpose of this study was to develop different injectable nanosized drug delivery systems (NDDSs) i.e. liposome, lipid nanocapsule (LNC) and polymeric nanocapsule (PNC) encapsulating apigenin (AG) and compare their characteristics to identify the nanovector(s) that can deliver the largest quantity of AG while being biocompatible. Two liposomes with different surface characteristics (cationic and anionic), a LNC and a PNC were prepared. A novel tocopherol modified poly(ethylene glycol)-b-polyphosphate block-copolymer was used for the first time for the PNC preparation. The NDDSs were compared by their physicochemical characteristics, AG release, storage stability, stability in serum, complement consumption and toxicity against a human macrovascular endothelial cell line (EAhy926). The diameter and surface charge of the NDDSs were comparable with previously reported injectable nanocarriers. The NDDSs showed good encapsulation efficiency and drug loading. Moreover, the NDDSs were stable during storage and in fetal bovine serum for extended periods, showed low complement consumption and were non-toxic to EAhy926 cells up to high concentrations. Therefore, they can be considered as potential injectable nanocarriers of AG. Due to less pronounced burst effect and extended release characteristics, the nanocapsules could be favorable approaches for achieving prolonged pharmacological activity of AG using injectable NDDS. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Identification of protein components and quantitative immunoassay for SEC2 in staphylococcin injection.

    PubMed

    Ding, Ding; Huang, Peng; Sun, Hongying; Xue, Qiao; Pan, Yingqiu; Chen, Shuqing

    2009-08-15

    In China, staphylococcin injection has been commonly used in combined cancer therapy to enhance the systemic immune response and reduce the toxicities associated with chemotherapy or radiation therapy in the last decade. It is claimed that the main effective component is staphylococcal enterotoxin C2 (SEC2). However, no standard method based on the concentration of SEC2 has been established for quality control of the injection products. In this study, a sensitive and reliable biotin-streptavidin-ELISA (BS-ELISA) method was established for detection and quantification of SEC2. In addition, 1-D SDS-PAGE coupled with nano-LC-MS/MS was performed to identify the protein components in the injection products from one manufacturing company. The results of the BS-ELISA showed that SEC2 only accounted for less than 0.1% of the total protein in the injection products, and the nano-LC-MS/MS results showed that fifty-five proteins of Staphylococcus aureus were confidently identified in the injection solution. Seventeen out of these proteins, including SEC2, were well-known virulence factors. In addition, eighteen proteins of other Gram-positive bacteria were also confidently identified. Thus, the results indicated that SEC2 is of very low concentration in the injection products and the process of the injection preparation should be improved for health and safety consideration.

  16. Safe use of epidural corticosteroid injections: recommendations of the WIP Benelux workgroup.

    PubMed

    Van Boxem, Koen; Rijsdijk, Mienke; Hans, Guy; de Jong, Jasper; Kallewaard, Jan Willem; Vissers, Kris; van Kleef, Maarten; Rathmell, James P; Van Zundert, Jan

    2018-05-14

    Epidural corticosteroid injections are used frequently worldwide in the treatment of radicular pain. Concerns have risen involving rare major neurologic injuries after this treatment. Recommendations to prevent these complications have been published, but local implementation is not always feasible due to local circumstances and necessitating local recommendations based on literature review. A workgroup of 4 stakeholder pain societies in Belgium, The Netherlands and Luxembourg (Benelux) has reviewed the literature involving neurological complications after epidural corticosteroid injections and possible safety measures to prevent these major neurologic injuries. Twenty-six considerations and recommendations were selected by the workgroup. These involve the use of imaging, injection equipment particulate and non-particulate corticosteroids, epidural approach and maximal volume to be injected. Raising awareness about possible neurological complications and adoption of safety measures recommended by the work group aim at reducing the risks of these devastating events. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  17. 30 CFR 250.1630 - Safety-system testing and records.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Sulphur Operations § 250.1630 Safety... components, and the following: (1) Safety relief valves on the natural gas feed system for power plant... source. (2) The following safety devices (excluding electronic pressure transmitters and level sensors...

  18. Installation, maintenance and operating manual for the Lucas-type fuel injection system of the 3 B rotary engine

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The installation procedure, maintenance, adjustment and operation of a Lucas type fuel injection system for 13B rotary racing engine is outlined. Components of the fuel injection system and installation procedure and notes are described. Maintenance, adjustment, and operation are discussed.

  19. Leading Edge. Volume 7, Number 3. Systems Safety Engineering

    DTIC Science & Technology

    2010-01-01

    solvents during manu- facturing • Toxic gas and noise resulting from weapon firing • Cadmium exposure associated with han- dling of corroded equipment...California • System Safety certificate ◆ University of Southern California • Master of Science degree in Safety Sciences ◆ Indiana University of...Master of Science degree program in Health and Safety, with a Specialization in Occupa- tional Safety Management ◆ Indiana State University, Distance

  20. The Art World's Concept of Negative Space Applied to System Safety Management

    NASA Technical Reports Server (NTRS)

    Goodin, James Ronald (Ronnie)

    2005-01-01

    Tools from several different disciplines can improve system safety management. This paper relates the Art World with our system safety world, showing useful art schools of thought applied to system safety management, developing an art theory-system safety bridge. This bridge is then used to demonstrate relations with risk management, the legal system, personnel management and basic management (establishing priorities). One goal of this presentation/paper is simply to be a fun diversion from the many technical topics presented during the conference.

  1. Treatment of Lipoma by Injection Lipolysis

    PubMed Central

    Nanda, Soni

    2011-01-01

    Injection lipolysis or lipodissolve is the practice of injecting phosphatidyl choline/ sodium deoxycholate (PDC/DC) compounds in the subcutaneous fat. Though this practice is being used extensively for nonsurgical contouring of body and dissolving localized collections of excess fat, it's use as a treatment modality for lipomas needs further evaluation. We present a case where this technique was used for treating a lipoma, with no recurrence after 9 months of follow up. Injection lipolysis as a treatment modality for lipomas needs to be evaluated for safety and efficacy in trials on larger population. This could prove to be a very valuable adjunct to the current practice of excision, if done by a trained person in a properly selected patient. Also the side effects and the controversies regarding this procedure have been discussed in detail in the present paper. PMID:21976907

  2. Hybrid wireless-over-fiber transmission system based on multiple injection-locked FP LDs.

    PubMed

    Li, Chung-Yi; Lu, Hai-Han; Chu, Chien-An; Ying, Cheng-Ling; Lu, Ting-Chien; Peng, Peng-Chun

    2015-07-27

    A hybrid wireless-over-fiber (WoF) transmission system based on multiple injection-locked Fabry-Perot laser diodes (FP LDs) is proposed and experimentally demonstrated. Unlike the traditional hybrid WoF transmission systems that require multiple distributed feedback (DFB) LDs to support different kinds of services, the proposed system employs multiple injection-locked FP LDs to provide different kinds of applications. Such a hybrid WoF transmission system delivers downstream intensity-modulated 20-GHz microwave (MW)/60-GHz millimeter-wave (MMW)/550-MHz cable television (CATV) signals and upstream phase-remodulated 20-GHz MW signal. Excellent bit error rate (BER), carrier-to-noise ratio (CNR), composite second-order (CSO), and composite triple-beat (CTB) are observed over a 40-km single-mode fiber (SMF) and a 4-m radio frequency (RF) wireless transport. Such a hybrid WoF transmission system has practical applications for fiber-wireless convergence to provide broadband integrated services, including telecommunication, data communication, and CATV services.

  3. Evaluating the effectiveness of active vehicle safety systems.

    PubMed

    Jeong, Eunbi; Oh, Cheol

    2017-03-01

    Advanced vehicle safety systems have been widely introduced in transportation systems and are expected to enhance traffic safety. However, these technologies mainly focus on assisting individual vehicles that are equipped with them, and less effort has been made to identify the effect of vehicular technologies on the traffic stream. This study proposed a methodology to assess the effectiveness of active vehicle safety systems (AVSSs), which represent a promising technology to prevent traffic crashes and mitigate injury severity. The proposed AVSS consists of longitudinal and lateral vehicle control systems, which corresponds to the Level 2 vehicle automation presented by the National Highway Safety Administration (NHTSA). The effectiveness evaluation for the proposed technology was conducted in terms of crash potential reduction and congestion mitigation. A microscopic traffic simulator, VISSIM, was used to simulate freeway traffic stream and collect vehicle-maneuvering data. In addition, an external application program interface, VISSIM's COM-interface, was used to implement the AVSS. A surrogate safety assessment model (SSAM) was used to derive indirect safety measures to evaluate the effectiveness of the AVSS. A 16.7-km freeway stretch between the Nakdong and Seonsan interchanges on Korean freeway 45 was selected for the simulation experiments to evaluate the effectiveness of AVSS. A total of five simulation runs for each evaluation scenario were conducted. For the non-incident conditions, the rear-end and lane-change conflicts were reduced by 78.8% and 17.3%, respectively, under the level of service (LOS) D traffic conditions. In addition, the average delay was reduced by 55.5%. However, the system's effectiveness was weakened in the LOS A-C categories. Under incident traffic conditions, the number of rear-end conflicts was reduced by approximately 9.7%. Vehicle delays were reduced by approximately 43.9% with 100% of market penetration rate (MPR). These results

  4. The NASA Aviation Safety Reporting System

    NASA Technical Reports Server (NTRS)

    1983-01-01

    This is the fourteenth in a series of reports based on safety-related incidents submitted to the NASA Aviation Safety Reporting System by pilots, controllers, and, occasionally, other participants in the National Aviation System (refs. 1-13). ASRS operates under a memorandum of agreement between the National Aviation and Space Administration and the Federal Aviation Administration. The report contains, first, a special study prepared by the ASRS Office Staff, of pilot- and controller-submitted reports related to the perceived operation of the ATC system since the 1981 walkout of the controllers' labor organization. Next is a research paper analyzing incidents occurring while single-pilot crews were conducting IFR flights. A third section presents a selection of Alert Bulletins issued by ASRS, with the responses they have elicited from FAA and others concerned. Finally, the report contains a list of publications produced by ASRS with instructions for obtaining them.

  5. Regulatory system reform of occupational health and safety in China.

    PubMed

    Wu, Fenghong; Chi, Yan

    2015-01-01

    With the explosive economic growth and social development, China's regulatory system of occupational health and safety now faces more and more challenges. This article reviews the history of regulatory system of occupational health and safety in China, as well as the current reform of this regulatory system in the country. Comprehensive, a range of laws, regulations and standards that promulgated by Chinese government, duties and responsibilities of the regulatory departments are described. Problems of current regulatory system, the ongoing adjustments and changes for modifying and improving regulatory system are discussed. The aim of reform and the incentives to drive forward more health and safety conditions in workplaces are also outlined.

  6. Can cyclist safety be improved with intelligent transport systems?

    PubMed

    Silla, Anne; Leden, Lars; Rämä, Pirkko; Scholliers, Johan; Van Noort, Martijn; Bell, Daniel

    2017-08-01

    In recent years, Intelligent Transport Systems (ITS) have assisted in the decrease of road traffic fatalities, particularly amongst passenger car occupants. Vulnerable Road Users (VRUs) such as pedestrians, cyclists, moped riders and motorcyclists, however, have not been that much in focus when developing ITS. Therefore, there is a clear need for ITS which specifically address VRUs as an integrated element of the traffic system. This paper presents the results of a quantitative safety impact assessment of five systems that were estimated to have high potential to improve the safety of cyclists, namely: Blind Spot Detection (BSD), Bicycle to Vehicle communication (B2V), Intersection safety (INS), Pedestrian and Cyclist Detection System+Emergency Braking (PCDS+EBR) and VRU Beacon System (VBS). An ex-ante assessment method proposed by Kulmala (2010) targeted to assess the effects of ITS for cars was applied and further developed in this study to assess the safety impacts of ITS specifically designed for VRUs. The main results of the assessment showed that all investigated systems affect cyclist safety in a positive way by preventing fatalities and injuries. The estimates considering 2012 accident data and full penetration showed that the highest effects could be obtained by the implementation of PCDS+EBR and B2V, whereas VBS had the lowest effect. The estimated yearly reduction in cyclist fatalities in the EU-28 varied between 77 and 286 per system. A forecast for 2030, taking into accounts the estimated accident trends and penetration rates, showed the highest effects for PCDS+EBR and BSD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Development of mediated BOD biosensor system of flow injection mode for shochu distillery wastewater.

    PubMed

    Oota, Shinichi; Hatae, Yuta; Amada, Kei; Koya, Hidekazu; Kawakami, Mitsuyasu

    2010-09-15

    Although microbial biochemical oxygen demand (BOD) sensors utilizing redox mediators have attracted much attention as a rapid BOD measurement method, little attempts have been made to apply the mediated BOD biosensors to the flow injection analysis system. In this work, a mediated BOD sensor system of flow injection mode, constructed by combining an immobilized microbial reactor with an electrochemical flow cell of three electrodes configuration, has been developed to estimate BOD of shochu distillery wastewater (SDW). It was demonstrated consequently that the mediated sensing was realized by employing phosphate buffer containing potassium hexacyanoferrate as the carrier. The output current was found to yield a peak with a sample injection, and to result from reoxidation of reduced mediator at the electrode. By employing the peak area as the sensor response, the effects of flow rate and pH of the carrier on the sensitivity were investigated. The sensor system using a microorganism of high SDW-assimilation capacity showed good performance and proved to be available for estimation of BOD of SDW. Copyright 2010 Elsevier B.V. All rights reserved.

  8. Towards a Usability and Error "Safety Net": A Multi-Phased Multi-Method Approach to Ensuring System Usability and Safety.

    PubMed

    Kushniruk, Andre; Senathirajah, Yalini; Borycki, Elizabeth

    2017-01-01

    The usability and safety of health information systems have become major issues in the design and implementation of useful healthcare IT. In this paper we describe a multi-phased multi-method approach to integrating usability engineering methods into system testing to ensure both usability and safety of healthcare IT upon widespread deployment. The approach involves usability testing followed by clinical simulation (conducted in-situ) and "near-live" recording of user interactions with systems. At key stages in this process, usability problems are identified and rectified forming a usability and technology-induced error "safety net" that catches different types of usability and safety problems prior to releasing systems widely in healthcare settings.

  9. Safety Systems

    ERIC Educational Resources Information Center

    Halligan, Tom

    2009-01-01

    Colleges across the country are rising to the task by implementing safety programs, response strategies, and technologies intended to create a secure environment for teachers and students. Whether it is preparing and responding to a natural disaster, health emergency, or act of violence, more schools are making campus safety a top priority. At…

  10. Compressor Stall Recovery Through Tip Injection Assessed

    NASA Technical Reports Server (NTRS)

    Suder, Ken L.

    2001-01-01

    Aerodynamic stability is a fundamental limit in the compressor design process. The development of robust techniques for increasing stability has several benefits: enabling higher loading and fewer blades, increasing safety throughout a mission, increasing tolerance to stage mismatch during part-speed operation and speed transients, and providing an opportunity to match stages at the compressor maximum efficiency point, thus reducing fuel burn. Mass injection upstream of the tip of a high-speed axial compressor rotor is a stability enhancement approach known to be effective in suppressing stall in tip-critical rotors if the injection is activated before stall occurs. This approach to stall suppression requires that a reliable stall warning system be available. Tests have recently been performed to assess whether steady injection can also be used to recover from fully developed stall. If mass injection is effective in recovering from stall quickly enough to avoid structural damage or loss of engine power, then a stall warning system may not be required. The stall recovery tests were performed on a transonic compressor rotor at its design tip speed of 1475 ft/sec using four injectors evenly spaced around the compressor case upstream of the rotor. The injectors were connected to an external air source. In an actual engine application, the injected air would be supplied with compressor bleed air. The injectors were isolated from the air source by a fast-acting butterfly valve. With the injectors turned off, the compressor was throttled into stall. Air injection was then activated with no change in throttle setting by opening the butterfly valve. The compressor recovered from stall at a fixed throttle setting with the aid of tip injection. The unsteady operating characteristic of the rotor was measured during these tests using high-response pressure sensors located upstream and downstream of the rotor. The figure shows the results, where the unsteady pressure and mass

  11. Safety and effectiveness of a single and repeat intramuscular injection of a GnRH vaccine (GonaCon™) in adult female domestic cats.

    PubMed

    Vansandt, L M; Kutzler, M A; Fischer, A E; Morris, K N; Swanson, W F

    2017-04-01

    Sterilization is a key strategy to reduce the number of domestic cats entering and killed in shelters each year. However, surgical sterilization is expensive and labour-intensive and cannot fully address the 70 million free-roaming cats estimated to exist in the United States. GonaCon™ is a gonadotropin-releasing hormone vaccine originally developed for use as a wildlife immunocontraceptive. An earlier formulation was tested in domestic cats and found to be safe and effective for long-term contraception. However, the current Environmental Protection Agency (EPA)-registered formulation consists of a different antigen-carrier protein and increased antigen concentration and has never been tested in cats. A pilot study was undertaken to evaluate the short-term safety of a single GonaCon immunization, assess the consequences of vaccinated cats receiving an accidental second GonaCon injection and determine the humoral immune response to immunization. During Phase 1, cats in Group A (n = 3) received a single intramuscular injection of GonaCon and Group B (n = 3) received a single intramuscular injection of saline. During Phase 2, Group A received a second GonaCon injection and Group B received their initial GonaCon injection. All cats developed GnRH antibodies within 30 days of vaccine administration. The endpoint titre (1:1,024,000) was similar among all cats, and levels remained high throughout the duration of the study. Four cats developed a sterile, painless, self-limiting mass at the site of injection. The mean number of days to mass development was 110.3 (range, 18-249 days). In conclusion, this preliminary study suggests that the EPA-registered GonaCon formulation is safe for continued testing in domestic cats, an accidental revaccination should not increase the risk of a vaccine reaction and the EPA-registered formulation effectively elicits a strong humoral immune response. © 2016 Blackwell Verlag GmbH.

  12. New reactor technology: safety improvements in nuclear power systems.

    PubMed

    Corradini, M L

    2007-11-01

    Almost 450 nuclear power plants are currently operating throughout the world and supplying about 17% of the world's electricity. These plants perform safely, reliably, and have no free-release of byproducts to the environment. Given the current rate of growth in electricity demand and the ever growing concerns for the environment, nuclear power can only satisfy the need for electricity and other energy-intensive products if it can demonstrate (1) enhanced safety and system reliability, (2) minimal environmental impact via sustainable system designs, and (3) competitive economics. The U.S. Department of Energy with the international community has begun research on the next generation of nuclear energy systems that can be made available to the market by 2030 or earlier, and that can offer significant advances toward these challenging goals; in particular, six candidate reactor system designs have been identified. These future nuclear power systems will require advances in materials, reactor physics, as well as thermal-hydraulics to realize their full potential. However, all of these designs must demonstrate enhanced safety above and beyond current light water reactor systems if the next generation of nuclear power plants is to grow in number far beyond the current population. This paper reviews the advanced Generation-IV reactor systems and the key safety phenomena that must be considered to guarantee that enhanced safety can be assured in future nuclear reactor systems.

  13. Advanced Range Safety System for High Energy Vehicles

    NASA Technical Reports Server (NTRS)

    Claxton, Jeffrey S.; Linton, Donald F.

    2002-01-01

    The advanced range safety system project is a collaboration between the National Aeronautics and Space Administration and the United States Air Force to develop systems that would reduce costs and schedule for safety approval for new classes of unmanned high-energy vehicles. The mission-planning feature for this system would yield flight profiles that satisfy the mission requirements for the user while providing an increased quality of risk assessment, enhancing public safety. By improving the speed and accuracy of predicting risks to the public, mission planners would be able to expand flight envelopes significantly. Once in place, this system is expected to offer the flexibility of handling real-time risk management for the high-energy capabilities of hypersonic vehicles including autonomous return-from-orbit vehicles and extended flight profiles over land. Users of this system would include mission planners of Space Launch Initiative vehicles, space planes, and other high-energy vehicles. The real-time features of the system could make extended flight of a malfunctioning vehicle possible, in lieu of an immediate terminate decision. With this improved capability, the user would have more time for anomaly resolution and potential recovery of a malfunctioning vehicle.

  14. Advancing a sociotechnical systems approach to workplace safety – developing the conceptual framework

    PubMed Central

    Carayon, Pascale; Hancock, Peter; Leveson, Nancy; Noy, Ian; Sznelwar, Laerte; van Hootegem, Geert

    2015-01-01

    Traditional efforts to deal with the enormous problem of workplace safety have proved insufficient, as they have tended to neglect the broader sociotechnical environment that surrounds workers. Here, we advocate a sociotechnical systems approach that describes the complex multi-level system factors that contribute to workplace safety. From the literature on sociotechnical systems, complex systems and safety, we develop a sociotechnical model of workplace safety with concentric layers of the work system, socio-organisational context and the external environment. The future challenges that are identified through the model are highlighted. Practitioner Summary: Understanding the environmental, organisational and work system factors that contribute to workplace safety will help to develop more effective and integrated solutions to deal with persistent workplace safety problems. Solutions to improve workplace safety need to recognise the broad sociotechnical system and the respective interactions between the system elements and levels. PMID:25831959

  15. 14 CFR 415.127 - Flight safety system design and operation data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Expendable Launch Vehicle From a Non-Federal Launch Site § 415.127 Flight safety system design and operation...: flight termination system; command control system; tracking; telemetry; communications; flight safety... control system. (7) Flight termination system component storage, operating, and service life. A listing of...

  16. Multiple dopant injection system for small rocket engines

    NASA Technical Reports Server (NTRS)

    Sakala, G. G.; Raines, N. G.

    1992-01-01

    The Diagnostics Test Facility (DTF) at NASA's Stennis Space Center (SSC) was designed and built to provide a standard rocket engine exhaust plume for use in the research and development of engine health monitoring instrumentation. A 1000 lb thrust class liquid oxygen (LOX)-gaseous hydrogen (GH2) fueled rocket engine is used as the subscale plume source to simulate the SSME during experimentation and instrument development. The ability of the DTF to provide efficient, and low cost test operations makes it uniquely suited for plume diagnostic experimentation. The most unique feature of the DTF is the Multiple Dopant Injection System (MDIS) that is used to seed the exhaust plume with the desired element or metal alloy. The dopant injection takes place at the fuel injector, yielding a very uniform and homogeneous distribution of the seeding material in the exhaust plume. The MDIS allows during a single test firing of the DTF, the seeding of the exhaust plume with up to three different dopants and also provides distilled water base lines between the dopants. A number of plume diagnostic-related experiments have already utilized the unique capabilities of the DTF.

  17. Injectable nanocomposite cryogels for versatile protein drug delivery.

    PubMed

    Koshy, Sandeep T; Zhang, David K Y; Grolman, Joshua M; Stafford, Alexander G; Mooney, David J

    2018-01-01

    Sustained, localized protein delivery can enhance the safety and activity of protein drugs in diverse disease settings. While hydrogel systems are widely studied as vehicles for protein delivery, they often suffer from rapid release of encapsulated cargo, leading to a narrow duration of therapy, and protein cargo can be denatured by incompatibility with the hydrogel crosslinking chemistry. In this work, we describe injectable nanocomposite hydrogels that are capable of sustained, bioactive, release of a variety of encapsulated proteins. Injectable and porous cryogels were formed by bio-orthogonal crosslinking of alginate using tetrazine-norbornene coupling. To provide sustained release from these hydrogels, protein cargo was pre-adsorbed to charged Laponite nanoparticles that were incorporated within the walls of the cryogels. The presence of Laponite particles substantially hindered the release of a number of proteins that otherwise showed burst release from these hydrogels. By modifying the Laponite content within the hydrogels, the kinetics of protein release could be precisely tuned. This versatile strategy to control protein release simplifies the design of hydrogel drug delivery systems. Here we present an injectable nanocomposite hydrogel for simple and versatile controlled release of therapeutic proteins. Protein release from hydrogels often requires first entrapping the protein in particles and embedding these particles within the hydrogel to allow controlled protein release. This pre-encapsulation process can be cumbersome, can damage the protein's activity, and must be optimized for each protein of interest. The strategy presented in this work simply premixes the protein with charged nanoparticles that bind strongly with the protein. These protein-laden particles are then placed within a hydrogel and slowly release the protein into the surrounding environment. Using this method, tunable release from an injectable hydrogel can be achieved for a variety of

  18. 30 CFR 7.103 - Safety system control test.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sensors which will automatically activate the safety shutdown system and stop the engine before the... the temperature sensor in the exhaust gas stream which will automatically activate the safety shutdown... using a wet exhaust conditioner, determine the effectiveness of the temperature sensor in the exhaust...

  19. 30 CFR 7.103 - Safety system control test.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sensors which will automatically activate the safety shutdown system and stop the engine before the... the temperature sensor in the exhaust gas stream which will automatically activate the safety shutdown... using a wet exhaust conditioner, determine the effectiveness of the temperature sensor in the exhaust...

  20. 30 CFR 7.103 - Safety system control test.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sensors which will automatically activate the safety shutdown system and stop the engine before the... the temperature sensor in the exhaust gas stream which will automatically activate the safety shutdown... using a wet exhaust conditioner, determine the effectiveness of the temperature sensor in the exhaust...

  1. Simulation of data safety components for corporative systems

    NASA Astrophysics Data System (ADS)

    Yaremko, Svetlana A.; Kuzmina, Elena M.; Savchuk, Tamara O.; Krivonosov, Valeriy E.; Smolarz, Andrzej; Arman, Abenov; Smailova, Saule; Kalizhanova, Aliya

    2017-08-01

    The article deals with research of designing data safety components for corporations by means of mathematical simulations and modern information technologies. Simulation of threats ranks has been done which is based on definite values of data components. The rules of safety policy for corporative information systems have been presented. The ways of realization of safety policy rules have been proposed on the basis of taken conditions and appropriate class of valuable data protection.

  2. Impact of Passive Safety on FHR Instrumentation Systems Design and Classification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holcomb, David Eugene

    2015-01-01

    Fluoride salt-cooled high-temperature reactors (FHRs) will rely more extensively on passive safety than earlier reactor classes. 10CFR50 Appendix A, General Design Criteria for Nuclear Power Plants, establishes minimum design requirements to provide reasonable assurance of adequate safety. 10CFR50.69, Risk-Informed Categorization and Treatment of Structures, Systems and Components for Nuclear Power Reactors, provides guidance on how the safety significance of systems, structures, and components (SSCs) should be reflected in their regulatory treatment. The Nuclear Energy Institute (NEI) has provided 10 CFR 50.69 SSC Categorization Guideline (NEI-00-04) that factors in probabilistic risk assessment (PRA) model insights, as well as deterministic insights, throughmore » an integrated decision-making panel. Employing the PRA to inform deterministic requirements enables an appropriately balanced, technically sound categorization to be established. No FHR currently has an adequate PRA or set of design basis accidents to enable establishing the safety classification of its SSCs. While all SSCs used to comply with the general design criteria (GDCs) will be safety related, the intent is to limit the instrumentation risk significance through effective design and reliance on inherent passive safety characteristics. For example, FHRs have no safety-significant temperature threshold phenomena, thus enabling the primary and reserve reactivity control systems required by GDC 26 to be passively, thermally triggered at temperatures well below those for which core or primary coolant boundary damage would occur. Moreover, the passive thermal triggering of the primary and reserve shutdown systems may relegate the control rod drive motors to the control system, substantially decreasing the amount of safety-significant wiring needed. Similarly, FHR decay heat removal systems are intended to be running continuously to minimize the amount of safety-significant instrumentation needed to

  3. The complexity of patient safety reporting systems in UK dentistry.

    PubMed

    Renton, T; Master, S

    2016-10-21

    Since the 'Francis Report', UK regulation focusing on patient safety has significantly changed. Healthcare workers are increasingly involved in NHS England patient safety initiatives aimed at improving reporting and learning from patient safety incidents (PSIs). Unfortunately, dentistry remains 'isolated' from these main events and continues to have a poor record for reporting and learning from PSIs and other events, thus limiting improvement of patient safety in dentistry. The reasons for this situation are complex.This paper provides a review of the complexities of the existing systems and procedures in relation to patient safety in dentistry. It highlights the conflicting advice which is available and which further complicates an overly burdensome process. Recommendations are made to address these problems with systems and procedures supporting patient safety development in dentistry.

  4. System analysis of vehicle active safety problem

    NASA Astrophysics Data System (ADS)

    Buznikov, S. E.

    2018-02-01

    The problem of the road transport safety affects the vital interests of the most of the population and is characterized by a global level of significance. The system analysis of problem of creation of competitive active vehicle safety systems is presented as an interrelated complex of tasks of multi-criterion optimization and dynamic stabilization of the state variables of a controlled object. Solving them requires generation of all possible variants of technical solutions within the software and hardware domains and synthesis of the control, which is close to optimum. For implementing the task of the system analysis the Zwicky “morphological box” method is used. Creation of comprehensive active safety systems involves solution of the problem of preventing typical collisions. For solving it, a structured set of collisions is introduced with its elements being generated also using the Zwicky “morphological box” method. The obstacle speed, the longitudinal acceleration of the controlled object and the unpredictable changes in its movement direction due to certain faults, the road surface condition and the control errors are taken as structure variables that characterize the conditions of collisions. The conditions for preventing typical collisions are presented as inequalities for physical variables that define the state vector of the object and its dynamic limits.

  5. A Review of Injectable Polymeric Hydrogel Systems for Application in Bone Tissue Engineering.

    PubMed

    Kondiah, Pariksha J; Choonara, Yahya E; Kondiah, Pierre P D; Marimuthu, Thashree; Kumar, Pradeep; du Toit, Lisa C; Pillay, Viness

    2016-11-21

    Biodegradable, stimuli-responsive polymers are essential platforms in the field of drug delivery and injectable biomaterials for application of bone tissue engineering. Various thermo-responsive hydrogels display water-based homogenous properties to encapsulate, manipulate and transfer its contents to the surrounding tissue, in the least invasive manner. The success of bioengineered injectable tissue modified delivery systems depends significantly on their chemical, physical and biological properties. Irrespective of shape and defect geometry, injectable therapy has an unparalleled advantage in which intricate therapy sites can be effortlessly targeted with minimally invasive procedures. Using material testing, it was found that properties of stimuli-responsive hydrogel systems enhance cellular responses and cell distribution at any site prior to the transitional phase leading to gelation. The substantially hydrated nature allows significant simulation of the extracellular matrix (ECM), due to its similar structural properties. Significant current research strategies have been identified and reported to date by various institutions, with particular attention to thermo-responsive hydrogel delivery systems, and their pertinent focus for bone tissue engineering. Research on future perspective studies which have been proposed for evaluation, have also been reported in this review, directing considerable attention to the modification of delivering natural and synthetic polymers, to improve their biocompatibility and mechanical properties.

  6. 78 FR 9623 - Federal Motor Vehicle Safety Standards; Air Brake Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    ... [Docket No. NHTSA-2013-0011] RIN 2127-AL11 Federal Motor Vehicle Safety Standards; Air Brake Systems... rule that amended the Federal motor vehicle safety standard for air brake systems by requiring... published a final rule in the Federal Register amending Federal Motor Vehicle Safety Standard (FMVSS) No...

  7. Optics of ion beams for the neutral beam injection system on HL-2A Tokamak.

    PubMed

    Zou, G Q; Lei, G J; Cao, J Y; Duan, X R

    2012-07-01

    The ion beam optics for the neutral beam injection system on HL-2A Tokomak is studied by two- dimensional numerical simulation program firstly, where the emitting surface is taken at 100 Debye lengths from the plasma electrode. The mathematical formulation, computation techniques are described. Typical ion orbits, equipotential contours, and emittance diagram are shown. For a fixed geometry electrode, the effect of plasma density, plasma potential and plasma electron temperature on ion beam optics is examined, and the calculation reliability is confirmed by experimental results. In order to improve ion beam optics, the application of a small pre-acceleration voltage (∼100 V) between the plasma electrode and the arc discharge anode is reasonable, and a lower plasma electron temperature is desired. The results allow optimization of the ion beam optics in the neutral beam injection system on HL-2A Tokomak and provide guidelines for designing future neutral beam injection system on HL-2M Tokomak.

  8. Effect of Xuebijing injection on systemic lupus erythematosus in mice.

    PubMed

    Wang, Yan-bo; Wang, Qiang; Yao, Yong-ming; Sheng, Zhi-yong; Liu, Yu-feng

    2013-09-01

    To observe the effects of Xuebijing injection on dendritic cells (DCs) and T lymphocytes, and the potential mechanisms of its therapeutic effect on systemic lupus erythematosus (SLE). A widely used mouse model, SLE-prone BLLF1 mice aged 8-10 weeks, was employed. Mice were randomly divided into 4 groups: a normal group, a model group and two treatment groups treated with Xuebijing Injection with a dose of 6.4 mL/kg via intraperitoneal administration for SLE-prone BLLF1 mice aged 8 weeks (treatment A group) and 10 weeks (treatment B group). Renal tissue sections were stained with Masson's trichrome and periodic acid-silver methenamine. Histopathological changes in the kidney were evaluated by a light microscopy. The capacity of the DCs isolated from the spleen to stimulate the T cell proliferation in response to concanavalin A (Con A) was determined. Compared with the model group, levels of anti-dsDNA antibodies in the two treatment groups decreased remarkablly (P<0.01, P<0.05), and levels of serum creatinine and blood urea nitrogen increased (P<0.01, P<0.05). Pathological changes were found in the kidney in the model group. Histopathological abnormalities were alleviated in the two treatment groups. Treatment with Xuebijing injection also significantly upregulated the expression of CD80, CD86 and major histocompatibility class II by DCs compared with the model group (P<0.05). When splenic T lymphocytes from BLLF1 mice were co-cultured with DCs at ratios of 1:100, 1:150 and 1:200 for 3 and 5 days, the proliferation of T lymphocytes was suppressed compared with the normal group (P<0.05), but this was restored by Xuebijing Injection under the same conditions. In the model group, levels of tumor necrosis factor (TNF)-α in supernatants were significantly elevated compared with the normal group (P<0.01), interleukin-2 levels decreased (P<0.05), while these changes were significantly alleviated in the Xuebijing treatment groups. Xuebijing Injection alleviated renal injury

  9. Why System Safety Professionals Should Read Accident Reports

    NASA Technical Reports Server (NTRS)

    Holloway, C. M.; Johnson, C. W.

    2006-01-01

    System safety professionals, both researchers and practitioners, who regularly read accident reports reap important benefits. These benefits include an improved ability to separate myths from reality, including both myths about specific accidents and ones concerning accidents in general; an increased understanding of the consequences of unlikely events, which can help inform future designs; a greater recognition of the limits of mathematical models; and guidance on potentially relevant research directions that may contribute to safety improvements in future systems.

  10. X-Ray Studies of Delphi Diesel Injection Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Powell, Christopher

    2017-01-01

    This CRADA explored the performance of two different models of Delphi diesel injectors. For each injector, the valve needle motion was imaged from two lines of sight at three different injection pressures to characterize its 3D motion. The needle lift was quite repeatable, and followed the expected trend of faster lift with higher injection pressure. In addition, it was observed that the maximum lift increased with injection pressure, even after the valve reached its mechanical limit, indicating that the increased fuel pressure was causing compression or bending of the needle. The off-axis motion of the needle was found to bemore » significant in both measurement planes, though it was very repeatable from one injection event to the next. The effect of ambient pressure on the needle motion was explored at an injection pressure of 400 bar, with ambient pressure up to 15 bar. No effect of the elevated ambient pressure on the needle lift was observed. High-speed x-ray imaging of the spray as it first emerges from the injector nozzle was performed in order to characterize the near-nozzle morphology and breakup of the spray. While imaging was successful at low ambient pressure, the contrast of the images was reduced at high ambient pressures, and quantitative measurements of the morphology were precluded. The near-nozzle fuel distributions were measured using time-resolved x-ray radiography for three injection pressures at an ambient pressure of 33 bar. Increasing injection pressure caused the fuel distribution to narrow, as measured by the Full Width at Half Maximum of the mass distributions. The fuel distributions were quantified for the two injectors at each measurement condition, quantifying the impact that each experimental parameter has on the near-nozzle fuel and air mixture preparation.« less

  11. Information systems in food safety management.

    PubMed

    McMeekin, T A; Baranyi, J; Bowman, J; Dalgaard, P; Kirk, M; Ross, T; Schmid, S; Zwietering, M H

    2006-12-01

    Information systems are concerned with data capture, storage, analysis and retrieval. In the context of food safety management they are vital to assist decision making in a short time frame, potentially allowing decisions to be made and practices to be actioned in real time. Databases with information on microorganisms pertinent to the identification of foodborne pathogens, response of microbial populations to the environment and characteristics of foods and processing conditions are the cornerstone of food safety management systems. Such databases find application in: Identifying pathogens in food at the genus or species level using applied systematics in automated ways. Identifying pathogens below the species level by molecular subtyping, an approach successfully applied in epidemiological investigations of foodborne disease and the basis for national surveillance programs. Predictive modelling software, such as the Pathogen Modeling Program and Growth Predictor (that took over the main functions of Food Micromodel) the raw data of which were combined as the genesis of an international web based searchable database (ComBase). Expert systems combining databases on microbial characteristics, food composition and processing information with the resulting "pattern match" indicating problems that may arise from changes in product formulation or processing conditions. Computer software packages to aid the practical application of HACCP and risk assessment and decision trees to bring logical sequences to establishing and modifying food safety management practices. In addition there are many other uses of information systems that benefit food safety more globally, including: Rapid dissemination of information on foodborne disease outbreaks via websites or list servers carrying commentary from many sources, including the press and interest groups, on the reasons for and consequences of foodborne disease incidents. Active surveillance networks allowing rapid dissemination

  12. Regulatory system reform of occupational health and safety in China

    PubMed Central

    WU, Fenghong; CHI, Yan

    2015-01-01

    With the explosive economic growth and social development, China’s regulatory system of occupational health and safety now faces more and more challenges. This article reviews the history of regulatory system of occupational health and safety in China, as well as the current reform of this regulatory system in the country. Comprehensive, a range of laws, regulations and standards that promulgated by Chinese government, duties and responsibilities of the regulatory departments are described. Problems of current regulatory system, the ongoing adjustments and changes for modifying and improving regulatory system are discussed. The aim of reform and the incentives to drive forward more health and safety conditions in workplaces are also outlined. PMID:25843565

  13. Loosely Coupled GPS-Aided Inertial Navigation System for Range Safety

    NASA Technical Reports Server (NTRS)

    Heatwole, Scott; Lanzi, Raymond J.

    2010-01-01

    The Autonomous Flight Safety System (AFSS) aims to replace the human element of range safety operations, as well as reduce reliance on expensive, downrange assets for launches of expendable launch vehicles (ELVs). The system consists of multiple navigation sensors and flight computers that provide a highly reliable platform. It is designed to ensure that single-event failures in a flight computer or sensor will not bring down the whole system. The flight computer uses a rules-based structure derived from range safety requirements to make decisions whether or not to destroy the rocket.

  14. Scale Model Test and Transient Analysis of Steam Injector Driven Passive Core Injection System for Innovative-Simplified Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu

    A steam injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact compact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "high-efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and emergency core cooling system of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a severe accident-free concept). This paper describes the results of the scale model test, and the transient analysis of SI-driven passive core injection system (PCIS).

  15. 33 CFR 96.230 - What objectives must a safety management system meet?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... management system meet? 96.230 Section 96.230 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY VESSEL OPERATING REGULATIONS RULES FOR THE SAFE OPERATION OF VESSELS AND SAFETY MANAGEMENT SYSTEMS Company and Vessel Safety Management Systems § 96.230 What objectives must a safety...

  16. Integrated hydraulic and organophosphate pesticide injection simulations for enhancing event detection in water distribution systems.

    PubMed

    Schwartz, Rafi; Lahav, Ori; Ostfeld, Avi

    2014-10-15

    As a complementary step towards solving the general event detection problem of water distribution systems, injection of the organophosphate pesticides, chlorpyrifos (CP) and parathion (PA), were simulated at various locations within example networks and hydraulic parameters were calculated over 24-h duration. The uniqueness of this study is that the chemical reactions and byproducts of the contaminants' oxidation were also simulated, as well as other indicative water quality parameters such as alkalinity, acidity, pH and the total concentration of free chlorine species. The information on the change in water quality parameters induced by the contaminant injection may facilitate on-line detection of an actual event involving this specific substance and pave the way to development of a generic methodology for detecting events involving introduction of pesticides into water distribution systems. Simulation of the contaminant injection was performed at several nodes within two different networks. For each injection, concentrations of the relevant contaminants' mother and daughter species, free chlorine species and water quality parameters, were simulated at nodes downstream of the injection location. The results indicate that injection of these substances can be detected at certain conditions by a very rapid drop in Cl2, functioning as the indicative parameter, as well as a drop in alkalinity concentration and a small decrease in pH, both functioning as supporting parameters, whose usage may reduce false positive alarms. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Monitoring of subsurface injection of wastes, Florida

    USGS Publications Warehouse

    Vecchioli, John

    1979-01-01

    Injection of waste liquids into Florida's subsurface is physically feasible in many places but should be accompanied by monitoring of the waste-receiving aquifer system in addition to the injection facility. Monitoring of the interaction of factors including hydrogeologic conditions, well construction, waste volumes and characteristics, and potable-water sources is desirable to assure that fresh-water resources are not being adversely affected. An effective aquifer-system monitoring program includes on-site wells located close to an injection well and open to the next-higher permeable stratum, satellite wells located hundreds to several thousands of feet from an injection well and open to the receiving aquifer, and regional wells located miles from individual injection wells and open to the receiving aquifer. An extensive aquifer-system monitoring program associated with two waste-injection facilities near Pensacola, Florida, has provided data which have aided hydrologists to understand the aquifer system's response to the injection and, accordingly, to evaluate the potential for affecting the area's fresh-water resources.

  18. Editorial: emerging issues in sociotechnical systems thinking and workplace safety.

    PubMed

    Noy, Y Ian; Hettinger, Lawrence J; Dainoff, Marvin J; Carayon, Pascale; Leveson, Nancy G; Robertson, Michelle M; Courtney, Theodore K

    2015-01-01

    The burden of on-the-job accidents and fatalities and the harm of associated human suffering continue to present an important challenge for safety researchers and practitioners. While significant improvements have been achieved in recent decades, the workplace accident rate remains unacceptably high. This has spurred interest in the development of novel research approaches, with particular interest in the systemic influences of social/organisational and technological factors. In response, the Hopkinton Conference on Sociotechnical Systems and Safety was organised to assess the current state of knowledge in the area and to identify research priorities. Over the course of several months prior to the conference, leading international experts drafted collaborative, state-of-the-art reviews covering various aspects of sociotechnical systems and safety. These papers, presented in this special issue, cover topics ranging from the identification of key concepts and definitions to sociotechnical characteristics of safe and unsafe organisations. This paper provides an overview of the conference and introduces key themes and topics. Sociotechnical approaches to workplace safety are intended to draw practitioners' attention to the critical influence that systemic social/organisational and technological factors exert on safety-relevant outcomes. This paper introduces major themes addressed in the Hopkinton Conference within the context of current workplace safety research and practice challenges.

  19. Editorial: emerging issues in sociotechnical systems thinking and workplace safety

    PubMed Central

    Noy, Y. Ian; Hettinger, Lawrence J.; Dainoff, Marvin J.; Carayon, Pascale; Leveson, Nancy G.; Robertson, Michelle M.; Courtney, Theodore K.

    2015-01-01

    The burden of on-the-job accidents and fatalities and the harm of associated human suffering continue to present an important challenge for safety researchers and practitioners. While significant improvements have been achieved in recent decades, the workplace accident rate remains unacceptably high. This has spurred interest in the development of novel research approaches, with particular interest in the systemic influences of social/organisational and technological factors. In response, the Hopkinton Conference on Sociotechnical Systems and Safety was organised to assess the current state of knowledge in the area and to identify research priorities. Over the course of several months prior to the conference, leading international experts drafted collaborative, state-of-the-art reviews covering various aspects of sociotechnical systems and safety. These papers, presented in this special issue, cover topics ranging from the identification of key concepts and definitions to sociotechnical characteristics of safe and unsafe organisations. This paper provides an overview of the conference and introduces key themes and topics. Practitioner Summary: Sociotechnical approaches to workplace safety are intended to draw practitioners' attention to the critical influence that systemic social/organisational and technological factors exert on safety-relevant outcomes. This paper introduces major themes addressed in the Hopkinton Conference within the context of current workplace safety research and practice challenges. PMID:25819595

  20. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    PubMed

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  1. Improving patient safety by instructional systems design

    PubMed Central

    Battles, J B

    2006-01-01

    Education and training are important elements in patient safety, both as a potential contributing factor to risks and hazards of healthcare associated injury or harm and as an intervention to be used in eliminating or preventing such harm. All too often we have relied on training as the only interventions for patient safety without examining other alternatives or realizing that, in some cases, the training systems themselves are part of the problem. One way to ensure safety by design is to apply established design principles to education and training. Instructional systems design (ISD) is a systematic method of development of education and training programs for improved learner performance. The ISD process involves five integrated steps: analysis, development, design, implementation, and evaluation (ADDIE). The application of ISD using the ADDIE approach can eliminate or prevent education and training from being a contributing factor of health associated injury or harm, and can also be effective in preventing injury or harm. PMID:17142604

  2. Software for the occupational health and safety integrated management system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vătăsescu, Mihaela

    2015-03-10

    This paper intends to present the design and the production of a software for the Occupational Health and Safety Integrated Management System with the view to a rapid drawing up of the system documents in the field of occupational health and safety.

  3. Overview of Design, Lifecycle, and Safety for Computer-Based Systems

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo

    2015-01-01

    This document describes the need and justification for the development of a design guide for safety-relevant computer-based systems. This document also makes a contribution toward the design guide by presenting an overview of computer-based systems design, lifecycle, and safety.

  4. Determination of recharge fraction of injection water in combined abstraction-injection wells using continuous radon monitoring.

    PubMed

    Lee, Kil Yong; Kim, Yong-Chul; Cho, Soo Young; Kim, Seong Yun; Yoon, Yoon Yeol; Koh, Dong Chan; Ha, Kyucheol; Ko, Kyung-Seok

    2016-12-01

    The recharge fractions of injection water in combined abstraction-injection wells (AIW) were determined using continuous radon monitoring and radon mass balance model. The recharge system consists of three combined abstraction-injection wells, an observation well, a collection tank, an injection tank, and tubing for heating and transferring used groundwater. Groundwater was abstracted from an AIW and sprayed on the water-curtain heating facility and then the used groundwater was injected into the same AIW well by the recharge system. Radon concentrations of fresh groundwater in the AIWs and of used groundwater in the injection tank were measured continuously using a continuous radon monitoring system. Radon concentrations of fresh groundwater in the AIWs and used groundwater in the injection tank were in the ranges of 10,830-13,530 Bq/m 3 and 1500-5600 Bq/m 3 , respectively. A simple radon mass balance model was developed to estimate the recharge fraction of used groundwater in the AIWs. The recharge fraction in the 3 AIWs was in the range of 0.595-0.798. The time series recharge fraction could be obtained using the continuous radon monitoring system with a simple radon mass balance model. The results revealed that the radon mass balance model using continuous radon monitoring was effective for determining the time series recharge fractions in AIWs as well as for characterizing the recharge system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. 9 CFR 113.44 - Swine safety test.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Swine safety test. 113.44 Section 113... Procedures § 113.44 Swine safety test. The swine safety test provided in this section shall be conducted when.... (1) Inject each of two swine of the minimum age for which the product is recommended with the...

  6. 9 CFR 113.44 - Swine safety test.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Swine safety test. 113.44 Section 113... Procedures § 113.44 Swine safety test. The swine safety test provided in this section shall be conducted when.... (1) Inject each of two swine of the minimum age for which the product is recommended with the...

  7. 9 CFR 113.44 - Swine safety test.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Swine safety test. 113.44 Section 113... Procedures § 113.44 Swine safety test. The swine safety test provided in this section shall be conducted when.... (1) Inject each of two swine of the minimum age for which the product is recommended with the...

  8. 9 CFR 113.44 - Swine safety test.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Swine safety test. 113.44 Section 113... Procedures § 113.44 Swine safety test. The swine safety test provided in this section shall be conducted when.... (1) Inject each of two swine of the minimum age for which the product is recommended with the...

  9. 9 CFR 113.44 - Swine safety test.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Swine safety test. 113.44 Section 113... Procedures § 113.44 Swine safety test. The swine safety test provided in this section shall be conducted when.... (1) Inject each of two swine of the minimum age for which the product is recommended with the...

  10. Mines Systems Safety Improvement Using an Integrated Event Tree and Fault Tree Analysis

    NASA Astrophysics Data System (ADS)

    Kumar, Ranjan; Ghosh, Achyuta Krishna

    2017-04-01

    Mines systems such as ventilation system, strata support system, flame proof safety equipment, are exposed to dynamic operational conditions such as stress, humidity, dust, temperature, etc., and safety improvement of such systems can be done preferably during planning and design stage. However, the existing safety analysis methods do not handle the accident initiation and progression of mine systems explicitly. To bridge this gap, this paper presents an integrated Event Tree (ET) and Fault Tree (FT) approach for safety analysis and improvement of mine systems design. This approach includes ET and FT modeling coupled with redundancy allocation technique. In this method, a concept of top hazard probability is introduced for identifying system failure probability and redundancy is allocated to the system either at component or system level. A case study on mine methane explosion safety with two initiating events is performed. The results demonstrate that the presented method can reveal the accident scenarios and improve the safety of complex mine systems simultaneously.

  11. Reflections on system safety and the law

    NASA Technical Reports Server (NTRS)

    Hayes, D. F., Sr.

    1971-01-01

    The application of law to the determination of what constitutes safeness is discussed. The numerous factors are analyzed which enter into the decisions of courts in deciding what is safe and what is unsafe. It is pointed out that as technology changes, legal interpretations of safety also change. Arguements are given for the use of system safety techniques and better engineering analyses as instruments of defense against liability.

  12. [Expert investigation on food safety standard system framework construction in China].

    PubMed

    He, Xiang; Yan, Weixing; Fan, Yongxiang; Zeng, Biao; Peng, Zhen; Sun, Zhenqiu

    2013-09-01

    Through investigating food safety standard framework among food safety experts, to summarize the basic elements and principles of food safety standard system, and provide policy advices for food safety standards framework. A survey was carried out among 415 experts from government, professional institutions and the food industry/enterprises using the National Food Safety Standard System Construction Consultation Questionnaire designed in the name of the Secretariat of National Food Safety Standard Committee. Experts have different advices in each group about the principles of food product standards, food additive product standards, food related product standards, hygienic practice, test methods. According to the results, the best solution not only may reflect experts awareness of the work of food safety standards situation, but also provide advices for setting and revision of food safety standards for the next. Through experts investigation, the framework and guiding principles of food safety standard had been built.

  13. 14 CFR 25.1709 - System safety: EWIS.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false System safety: EWIS. 25.1709 Section 25.1709 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Electrical Wiring Interconnection Systems (EWIS) § 25.1709...

  14. Electrical detection of nuclear spin-echo signals in an electron spin injection system

    NASA Astrophysics Data System (ADS)

    Lin, Zhichao; Rasly, Mahmoud; Uemura, Tetsuya

    2017-06-01

    We demonstrated spin echoes of nuclear spins in a spin injection device with a highly polarized spin source by nuclear magnetic resonance (NMR). Efficient spin injection into GaAs from a half-metallic spin source of Co2MnSi enabled efficient dynamic nuclear polarization (DNP) and sensitive detection of NMR signals even at a low magnetic field of ˜0.1 T and a relatively high temperature of 4.2 K. The intrinsic coherence time T2 of 69Ga nuclear spins was evaluated from the spin-echo signals. The relation between T2 and the decay time of the Rabi oscillation suggests that the inhomogeneous effects in our system are not obvious. This study provides an all-electrical NMR system for nuclear-spin-based qubits.

  15. The osteogenic response of mesenchymal stem cells to an injectable PLGA bone regeneration system.

    PubMed

    Curran, Judith M; Fawcett, Sandra; Hamilton, Lloyd; Rhodes, Nicholas P; Rahman, Cheryl V; Alexander, Morgan; Shakesheff, Kevin; Hunt, John A

    2013-12-01

    The enrichment of substrates/surfaces with selected functional groups, methyl (-CH3), allyl amine (-NH2), allyl alcohol (-OH) and acrylic acid (-COOH), can be used to trigger mesenchymal stem (MSC) cell differentiation into specified lineages, minimising the need for exogenous biological supplementation. We present the successful translation of this research phenomenon to an injectable two phase injectable PLGA system, utilising plasma techniques, for the repair of bone defects. Modified microspheres were characterised using water contact angel (WCA), X-ray Photon Spectroscopy (XPS) and scanning electron microscopy (SEM). When cultured in contact with MSCs in vitro, the ability of the modified particles, within the 2 phase system, to induce differentiation was characterised using quantitative assays for cell viability and histological analysis for key markers of differentiation throughout the entirety of the three dimensional scaffold. Biological analysis proved that selected modified microspheres have the ability to induce MSC osteogenic (-NH2 modified scaffolds) and chondrogenic (-OH modified scaffolds) differentiation throughout the entirety of the formed scaffold. Therefore optimised plasma modification of microspheres is an effective tool for the production of injectable systems for the repair of bone and cartilage defects. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. NASA aviation safety reporting system

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Aviation safety reports that relate to loss of control in flight, problems that occur as a result of similar sounding alphanumerics, and pilot incapacitation are presented. Problems related to the go around maneuver in air carrier operations, and bulletins (and FAA responses to them) that pertain to air traffic control systems and procedures are included.

  17. Safety management of a complex R and D ground operating system

    NASA Technical Reports Server (NTRS)

    Connors, J. F.; Maurer, R. A.

    1975-01-01

    A perspective on safety program management was developed for a complex R&D operating system, such as the NASA-Lewis Research Center. Using a systems approach, hazardous operations are subjected to third-party reviews by designated-area safety committees and are maintained under safety permit controls. To insure personnel alertness, emergency containment forces and employees are trained in dry-run emergency simulation exercises. The keys to real safety effectiveness are top management support and visibility of residual risks.

  18. Ex-ante assessment of the safety effects of intelligent transport systems.

    PubMed

    Kulmala, Risto

    2010-07-01

    There is a need to develop a comprehensive framework for the safety assessment of Intelligent Transport Systems (ITS). This framework should: (1) cover all three dimensions of road safety-exposure, crash risk and consequence, (2) cover, in addition to the engineering effect, also the effects due to behavioural adaptation and (3) be compatible with the other aspects of state of the art road safety theories. A framework based on nine ITS safety mechanisms is proposed and discussed with regard to the requirements set to the framework. In order to illustrate the application of the framework in practice, the paper presents a method based on the framework and the results from applying that method for twelve intelligent vehicle systems in Europe. The framework is also compared to two recent frameworks applied in the safety assessment of intelligent vehicle safety systems. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. A sensor monitoring system for telemedicine, safety and security applications

    NASA Astrophysics Data System (ADS)

    Vlissidis, Nikolaos; Leonidas, Filippos; Giovanis, Christos; Marinos, Dimitrios; Aidinis, Konstantinos; Vassilopoulos, Christos; Pagiatakis, Gerasimos; Schmitt, Nikolaus; Pistner, Thomas; Klaue, Jirka

    2017-02-01

    A sensor system capable of medical, safety and security monitoring in avionic and other environments (e.g. homes) is examined. For application inside an aircraft cabin, the system relies on an optical cellular network that connects each seat to a server and uses a set of database applications to process data related to passengers' health, safety and security status. Health monitoring typically encompasses electrocardiogram, pulse oximetry and blood pressure, body temperature and respiration rate while safety and security monitoring is related to the standard flight attendance duties, such as cabin preparation for take-off, landing, flight in regions of turbulence, etc. In contrast to previous related works, this article focuses on the system's modules (medical and safety sensors and associated hardware), the database applications used for the overall control of the monitoring function and the potential use of the system for security applications. Further tests involving medical, safety and security sensing performed in an real A340 mock-up set-up are also described and reference is made to the possible use of the sensing system in alternative environments and applications, such as health monitoring within other means of transport (e.g. trains or small passenger sea vessels) as well as for remotely located home users, over a wired Ethernet network or the Internet.

  20. Integration of functional safety systems on the Daniel K. Inouye Solar Telescope

    NASA Astrophysics Data System (ADS)

    Williams, Timothy R.; Hubbard, Robert P.; Shimko, Steve

    2016-07-01

    The Daniel K. Inouye Solar Telescope (DKIST) was envisioned from an early stage to incorporate a functional safety system to ensure the safety of personnel and equipment within the facility. Early hazard analysis showed the need for a functional safety system. The design used a distributed approach in which each major subsystem contains a PLC-based safety controller. This PLC-based system complies with the latest international standards for functional safety. The use of a programmable controller also allows for flexibility to incorporate changes in the design of subsystems without adversely impacting safety. Various subsystems were built by different contractors and project partners but had to function as a piece of the overall control system. Using distributed controllers allows project contractors and partners to build components as standalone subsystems that then need to be integrated into the overall functional safety system. Recently factory testing was concluded on the major subsystems of the facility. Final integration of these subsystems is currently underway on the site. Building on lessons learned in early factory tests, changes to the interface between subsystems were made to improve the speed and ease of integration of the entire system. Because of the distributed design each subsystem can be brought online as it is delivered and assembled rather than waiting until the entire facility is finished. This enhances safety during the risky period of integration and testing. The DKIST has implemented a functional safety system that has allowed construction of subsystems in geographically diverse locations but that function cohesively once they are integrated into the facility currently under construction.