Sample records for salisbury eye evaluation

  1. A comprehensive assessment of visual impairment in a population of older Americans. The SEE Study. Salisbury Eye Evaluation Project.

    PubMed

    Rubin, G S; West, S K; Muñoz, B; Bandeen-Roche, K; Zeger, S; Schein, O; Fried, L P

    1997-03-01

    The Salisbury Eye Evaluation Project is a longitudinal study of risk factors for age-related eye diseases and the impact of eye disease and visual impairment on physical disability. In this article, the authors report the prevalence of visual impairment in their population and explore the relations among the various measures of visual function. A population-based sample of 2520 residents of Salisbury, Maryland, between the ages of 65 and 84 years were enrolled in the study. Twenty-six percent of participants were black. Vision tests included best-corrected Early Treatment Diabetic Retinopathy Study acuity, Pelli-Robson contrast sensitivity with and without glare, Randot stereoacuity, and 60 degrees Humphrey visual fields. Visual function decreased linearly with age for the acuity, contrast sensitivity, glare, and visual field tests. Stereoacuity remained constant into the mid-70s and declined at an accelerating rate thereafter. Black participants had lower contrast sensitivity, reduced stereoacuity, and worse visual fields, at all ages compared to white participants; however, white participants were more sensitive to glare. The overall prevalence of visual acuity impairment in blacks was 5.6% versus 3.0% for whites, using the traditional United States definition (worse than 20/40 to better than 20/200) and 3.3% for blacks versus 1.6% for whites, using the World Health Organization definition (worse than 20/60 to 20/400). Acuity was correlated moderately with contrast sensitivity, stereoacuity, and visual fields (Spearman rho = 0.50, 0.35, and 0.34, respectively). The correlation between acuity and glare sensitivity was low (rho = 0.12). Many aspects of visual function, not just acuity, decline with age. Black participants have more visual impairement than do white participants for all tests except glare sensitivity. The prevalence of visual acuity impairement in the Salisbury Eye Evaluation population is lower than that reported by other studies using similar test

  2. Older drivers and rapid deceleration events: Salisbury Eye Evaluation Driving Study.

    PubMed

    Keay, Lisa; Munoz, Beatriz; Duncan, Donald D; Hahn, Daniel; Baldwin, Kevin; Turano, Kathleen A; Munro, Cynthia A; Bandeen-Roche, Karen; West, Sheila K

    2013-09-01

    Drivers who rapidly change speed while driving may be more at risk for a crash. We sought to determine the relationship of demographic, vision, and cognitive variables with episodes of rapid decelerations during five days of normal driving in a cohort of older drivers. In the Salisbury Eye Evaluation Driving Study, 1425 older drivers aged 67-87 were recruited from the Maryland Motor Vehicle Administration's rolls for licensees in Salisbury, Maryland. Participants had several measures of vision tested: visual acuity, contrast sensitivity, visual fields, and the attentional visual field. Participants were also tested for various domains of cognitive function including executive function, attention, psychomotor speed, and visual search. A custom created driving monitoring system (DMS) was used to capture rapid deceleration events (RDEs), defined as at least 350 milli-g deceleration, during a five day period of monitoring. The rate of RDE per mile driven was modeled using a negative binomial regression model with an offset of the logarithm of the number of miles driven. We found that 30% of older drivers had one or more RDE during a five day period, and of those, about 1/3 had four or more. The rate of RDE per mile driven was highest for those drivers driving<59 miles during the 5-day period of monitoring. However, older drivers with RDE's were more likely to have better scores in cognitive tests of psychomotor speed and visual search, and have faster brake reaction time. Further, greater average speed and maximum speed per driving segment was protective against RDE events. In conclusion, contrary to our hypothesis, older drivers who perform rapid decelerations tend to be more "fit", with better measures of vision and cognition compared to those who do not have events of rapid deceleration. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Older Drivers and Rapid Deceleration Events: Salisbury Eye Evaluation Driving Study

    PubMed Central

    Keay, Lisa; Munoz, Beatriz; Duncan, Donald D; Hahn, Daniel; Baldwin, Kevin; Turano, Kathleen A; Munro, Cynthia A; Bandeen-Roche, Karen; West, Sheila K

    2012-01-01

    Drivers who rapidly change speed while driving may be more at risk for a crash. We sought to determine the relationship of demographic, vision, and cognitive variables with episodes of rapid decelerations during five days of normal driving in a cohort of older drivers. In the Salisbury Eye Evaluation Driving Study, 1425 older drivers ages 67 to 87 were recruited from the Maryland Motor Vehicle Administration’s rolls for licensees in Salisbury, Maryland. Participants had several measures of vision tested: visual acuity, contrast sensitivity, visual fields, and the attentional visual field. Participants were also tested for various domains of cognitive function including executive function, attention, psychomotor speed, and visual search. A custom created Driving Monitor System (DMS) was used to capture rapid deceleration events (RDE), defined as at least 350 milli-g deceleration, during a five day period of monitoring. The rate of RDE per mile driven was modeled using a negative binomial regression model with an offset of the logarithm of the number of miles driven. We found that 30% of older drivers had one or more RDE during a five day period, and of those, about 1/3 had four or more. The rate of RDE per mile driven was highest for those drivers driving <59 miles during the 5-day period of monitoring. However, older drivers with RDE’s were more likely to have better scores in cognitive tests of psychomotor speed and visual search, and have faster brake reaction time. Further, greater average speed and maximum speed per driving segment was protective against RDE events. In conclusion, contrary to our hypothesis, older drivers who perform rapid decelerations tend to be more “fit”, with better measures of vision and cognition compared to those who do not have events of rapid deceleration. PMID:22742775

  4. Does Visual Impairment Affect Mobility Over Time? The Salisbury Eye Evaluation Study

    PubMed Central

    Swenor, Bonnielin K.; Muñoz, Beatriz; West, Sheila K.

    2013-01-01

    Purpose. To determine if the odds of mobility disability increases at a different rate among visually impaired (VI) as compared with nonvisually impaired (NVI) over an 8-year period. Methods. A total of 2520 Salisbury Eye Evaluation Study participants were followed 2, 6, and 8 years after baseline. VI was defined as best-corrected visual acuity worse than 20/40, or visual field of approximately less than 20°. Self-reported difficulty with three tasks was assessed at each visit: walking up 10 steps, walking down 10 steps, and walking 150 feet. Generalized estimating equation models included a 6-year spline, and explored differences in mobility difficulty trajectories by including an interaction between VI status and the spline terms. Odds ratios (OR) and 95% confidence intervals (CI) compared mobility difficulty for each task by VI status. Results. At baseline, the VI were significantly more likely to report difficulty mobility tasks than the NVI (ORdifficultywalkingup10steps = 1.37, CI: 1.02–1.80; ORdifficultywalkingdown10steps = 1.55, CI: 1.16–2.08; ORdifficultywalking150feet = 1.50, CI: 1.10–2.04). The trajectory of mobility disability did not differ by VI status from baseline to the 6-year visit. However, the difference between the VI and NVI declined at the 8-year visit, which may be due to loss of VI participants at risk of developing mobility difficulty. Conclusions. The VI were more likely to report mobility disability than the NVI, but the trajectory of mobility disability was not steeper among the VI as compared to the NVI over the study period. PMID:24176902

  5. Does walking speed mediate the association between visual impairment and self-report of mobility disability? The Salisbury Eye Evaluation Study.

    PubMed

    Swenor, Bonnielin K; Bandeen-Roche, Karen; Muñoz, Beatriz; West, Sheila K

    2014-08-01

    To determine whether performance speeds mediate the association between visual impairment and self-reported mobility disability over an 8-year period. Longitudinal analysis. Salisbury, Maryland. Salisbury Eye Evaluation Study participants aged 65 and older (N=2,520). Visual impairment was defined as best-corrected visual acuity worse than 20/40 in the better-seeing eye or visual field less than 20°. Self-reported mobility disability on three tasks was assessed: walking up stairs, walking down stairs, and walking 150 feet. Performance speed on three similar tasks was measured: walking up steps (steps/s), walking down steps (steps/s), and walking 4 m (m/s). For each year of observation, the odds of reporting mobility disability was significantly greater for participants who were visually impaired (VI) than for those who were not (NVI) (odds ratio (OR) difficulty walking up steps=1.58, 95% confidence interval (CI)=1.32-1.89; OR difficulty walking down steps=1.90, 95% CI=1.59-2.28; OR difficulty walking 150 feet=2.11, 95% CI=1.77-2.51). Once performance speed on a similar mobility task was included in the models, VI participants were no longer more likely to report mobility disability than those who were NVI (OR difficulty walking up steps=0.84, 95% CI=0.65-1.11; OR difficulty walking down steps=0.96, 95% CI=0.74-1.24; OR difficulty walking 150 feet=1.22, 95% CI=0.98-1.50). Slower performance speed in VI individuals largely accounted for the difference in the odds of reporting mobility disability, suggesting that VI older adults walk slower and are therefore more likely to report mobility disability than those who are NVI. Improving mobility performance in older adults with visual impairment may minimize the perception of mobility disability. © 2014, Copyright the Authors Journal compilation © 2014, The American Geriatrics Society.

  6. Comparing the Impact of Refractive and Nonrefractive Vision Loss on Functioning and Disability: The Salisbury Eye Evaluation.

    PubMed

    Zebardast, Nazlee; Swenor, Bonnielin K; van Landingham, Suzanne W; Massof, Robert W; Munoz, Beatriz; West, Sheila K; Ramulu, Pradeep Y

    2015-06-01

    To compare the effects of uncorrected refractive error (URE) and nonrefractive visual impairment (VI) on performance and disability measures. Cross-sectional, population-based study. A total of 2469 individuals with binocular presenting visual acuity (PVA) of ≥ 20/80 who participated in the first round of the Salisbury Eye Evaluation study. The URE was defined as binocular PVA of ≤ 20/30, improving to >20/30 with subjective refraction. The VI was defined as post-refraction binocular best-corrected visual acuity (BCVA) of ≤ 20/30. The visual acuity decrement due to VI was calculated as the difference between BCVA and 20/30, whereas visual acuity due to URE was taken as the difference between PVA and BCVA. Multivariable regression analyses were used to assess the disability impact of (1) vision status (VI, URE, or normal vision) using the group with normal vision as reference and (2) a 1-line decrement in acuity due to VI or URE. Objective measures of visual function were obtained from timed performance of mobility and near vision tasks, self-reported driving cessation, and self-reported visual difficulty measured by the Activities of Daily Vision (ADV) scale. The ADV responses were analyzed using Rasch analysis to determine visual ability. Compared with individuals with normal vision, subjects with VI (n = 191) had significantly poorer objective and subjective visual functioning in all metrics examined (P < 0.05), whereas subjects with URE (n = 132) demonstrated slower walking speeds, slower near task performance, more frequent driving cessation, and lower ADV scores (P < 0.05), but did not demonstrate slower stair climbing or descent speed. For all functional metrics evaluated, the impact of VI was greater than the impact of URE. The impact of a 1-line VA decrement due to VI was associated with greater deficits in mobility measures and driving cessation when compared with a 1-line VA decrement due to URE. Visual impairment is associated with greater

  7. Comparing the Impact of Refractive and Non-Refractive Vision Loss on Functioning and Disability: The Salisbury Eye Evaluation

    PubMed Central

    Zebardast, Nazlee; Swenor, Bonnielin K.; van Landingham, Suzanne W.; Massof, Robert W.; Munoz, Beatriz; West, Sheila K.; Ramulu, Pradeep Y.

    2015-01-01

    Purpose To compare the effects of uncorrected refractive error (URE) and non-refractive visual impairment (VI) on performance and disability measures. Design Cross-sectional population-based study. Participants 2469 individuals with binocular presenting visual acuity (PVA) of 20/80 or better who participated in the first round of the Salisbury Eye Evaluation study. Methods URE was defined as binocular PVA of 20/30 or worse, improving to better than 20/30 with subjective refraction. VI was defined as post-refraction binocular best corrected visual acuity (BCVA) of 20/30 or worse. The visual acuity decrement attributable to VI was calculated as the difference between BCVA and 20/30 while that due to URE was taken as the difference between PVA and BCVA. Multivariable regression analyses were used to assess the disability impact of 1) vision status (VI, URE, or normal vision) using the group with normal vision as reference, and 2) a one-line decrement in acuity due to VI or URE. Main Outcome Measures Objective measures of visual function were obtained from timed performance of mobility and near vision tasks, self-reported driving cessation, and self-reported visual difficulty measured by the Activities of Daily Vision (ADV) scale. ADV responses were analyzed using Rasch analysis to determine visual ability. Results Compared to individuals with normal vision, subjects with VI (n=191) had significantly poorer objective and subjective visual functioning in all metrics examined (p<0.05) while subjects with URE (n=132) demonstrated slower walking speeds, slower near task performance, more frequent driving cessation and lower ADV scores (p<0.05), but did not demonstrate slower stair climbing or descent speed. For all functional metrics evaluated, the impact of VI was greater than the impact of URE. The impact of a one-line VA decrement due to VI was associated with greater deficits in mobility measures and driving cessation when compared to a one-line VA decrement due to URE

  8. Study on the millimeter-wave scale absorber based on the Salisbury screen

    NASA Astrophysics Data System (ADS)

    Yuan, Liming; Dai, Fei; Xu, Yonggang; Zhang, Yuan

    2018-03-01

    In order to solve the problem on the millimeter-wave scale absorber, the Salisbury screen absorber is employed and designed based on the RL. By optimizing parameters including the sheet resistance of the surface resistive layer, the permittivity and the thickness of the grounded dielectric layer, the RL of the Salisbury screen absorber could be identical with that of the theoretical scale absorber. An example is given to verify the effectiveness of the method, where the Salisbury screen absorber is designed by the proposed method and compared with the theoretical scale absorber. Meanwhile, plate models and tri-corner reflector (TCR) models are constructed according to the designed result and their scattering properties are simulated by FEKO. Results reveal that the deviation between the designed Salisbury screen absorber and the theoretical scale absorber falls within the tolerance of radar Cross section (RCS) measurement. The work in this paper has important theoretical and practical significance in electromagnetic measurement of large scale ratio.

  9. Metasurface Salisbury screen: achieving ultra-wideband microwave absorption.

    PubMed

    Zhou, Ziheng; Chen, Ke; Zhao, Junming; Chen, Ping; Jiang, Tian; Zhu, Bo; Feng, Yijun; Li, Yue

    2017-11-27

    The metasurfaces have recently been demonstrated to provide full control of the phase responses of electromagnetic (EM) wave scattering over subwavelength scales, enabling a wide range of practical applications. Here, we propose a comprehensive scheme for the efficient and flexible design of metasurface Salisbury screen (MSS) capable of absorbing the impinging EM wave in an ultra-wide frequency band. We show that properly designed reflective metasurface can be used to substitute the metallic ground of conventional Salisbury screen for generating diverse resonances in a desirable way, thus providing large controllability over the absorption bandwidth. Based on this concept, we establish an equivalent circuit model to qualitatively analysis the resonances in MSS and design algorithms to optimize the overall performance of the MSS. Experiments have been carried out to demonstrate that the absorption bandwidth from 6 GHz to 30 GHz with an efficiency higher than 85% can be achieved by the proposal, which is apparently much larger than that of conventional Salisbury screen (7 GHz - 17 GHz). The proposed concept of MSS could offer opportunities for flexibly designing thin electromagnetic absorbers with simultaneously ultra-wide bandwidth, polarization insensitivity, and wide incident angle, exhibiting promising potentials for many applications such as in EM compatibility, stealth technique, etc.

  10. Visual and cognitive predictors of performance on brake reaction test: Salisbury eye evaluation driving study.

    PubMed

    Zhang, Lei; Baldwin, Kevin; Munoz, Beatriz; Munro, Cynthia; Turano, Kathleen; Hassan, Shirin; Lyketsos, Constantine; Bandeen-Roche, Karen; West, Sheila K

    2007-01-01

    Concern for driving safety has prompted research into understanding factors related to performance. Brake reaction speed (BRS), the speed with which persons react to a sudden change in driving conditions, is a measure of performance. Our aim is to determine the visual, cognitive, and physical factors predicting BRS in a population sample of 1425 older drivers. The Maryland Department of Motor Vehicles roster of persons aged 67-87 and residing in Salisbury, MD, was used for recruitment of the study population. Procedures included the following: habitual, binocular visual acuity using ETDRS charts, contrast sensitivity using a Pelli-Robson chart, visual fields assessed with a 81-point screening Humphrey field at a single intensity threshold, and a questionnaire to ascertain medical conditions. Cognitive status was assessed using a standard battery of tests for attention, memory, visuo-spatial, and scanning. BRS was assessed using a computer-driven device that measured separately the initial reaction speed (IRS) (from light change to red until removing foot from accelerator) and physical response speed (PRS) (removing foot from accelerator to full brake depression). Five trial times were averaged, and time was converted to speed. The median brake reaction time varied from 384 to 5688 milliseconds. Age, gender, and cognition predicted total BRS, a non-informative result as there are two distinct parts to the task. Once separated, decrease in IRS was associated with low scores on cognitive factors and missing points on the visual field. A decrease in PRS was associated with having three or more physical complaints related to legs and feet, and poorer vision search. Vision was not related to PRS. We have demonstrated the importance of segregating the speeds for the two tasks involved in brake reaction. Only the IRS depends on vision. Persons in good physical condition may perform poorly on brake reaction tests if their vision or cognition is compromised.

  11. "Writing My Way Home": An Interview with Graham Salisbury.

    ERIC Educational Resources Information Center

    Benton, Janet

    1997-01-01

    Contains an interview with Hawaiian writer Graham Salisbury about his young adult novels, such as "Blue Skin of the Sea,""Under the Blood-Red Sun," and "Shark Bait." Discusses the struggles and conflicts of boyhood. (TB)

  12. Familial Aggregation of Hyperopia in an Elderly Population of Siblings in Salisbury, Maryland

    PubMed Central

    Wojciechowski, Robert; Congdon, Nathan; Bowie, Heidi; Munoz, Beatriz; Gilbert, Donna; West, Sheila

    2011-01-01

    Purpose To determine whether hyperopia aggregates in families in an older mixed-race population. Design Cross-sectional familial aggregation study using sibships. Methods We recruited 759 subjects (mean age, 73.4 years) in 241 families through the population-based Salisbury Eye Evaluation study. Subjects underwent noncycloplegic refraction if best-corrected visual acuity (BCVA) was ≤20/40, had lensometry to measure their currently worn spectacles if BCVA was >20/40 with spectacles, or were considered to be plano (refraction of zero) if the BCVA was >20/40 without spectacles. Preoperative refraction from medical records was used for bilaterally pseudophakic subjects. Results Utilizing hyperopia cutoffs from 1.00 to 2.50 diopters, age-, race-, and gender-adjusted odds ratios for hyperopia with an affected sibling ranged from 2.72 (95% confidence interval [CI], 1.84–4.01) to 4.87 (95% CI, 2.54–9.30). The odds of hyperopia increased with age until 75 years, after which they remained relatively constant. Black men were significantly less likely to be hyperopic than white men, white women, or black women. Conclusions Hyperopia appears to be under strong genetic control in this older population. PMID:15629824

  13. Development of an Actuarial Science Program at Salisbury University

    ERIC Educational Resources Information Center

    Wainwright, Barbara A.

    2014-01-01

    This paper focuses on the development of an actuarial science track for the mathematics major at Salisbury University (SU). A timeline from the initial investigation into such a program through the proposal and approval processes is shared for those who might be interested in developing a new actuarial program. It is wise to start small and take…

  14. Mardela Middle and High School and Salisbury University PDS Partnership

    ERIC Educational Resources Information Center

    Siers, Ron, Jr.; Elburn, Sara; Gasior, Paul; Briggs, Rick; Ramey, Cathy

    2015-01-01

    Salisbury University (SU) has been preparing teachers since 1925 and has earned a stellar reputation in teacher preparation, especially through its work with PDS. In 2009, SU was honored with the NAPDS "Spirit of Partnership" award for its contributions to the annual national conference. SU and Worcester County Public Schools earned the…

  15. Review of Selected Documents Related to Flooding at City of Salisbury Facilities on the Yadkin River Upstream from High Rock Dam, North Carolina, September 2007

    USGS Publications Warehouse

    Bales, Jerad D.

    2007-01-01

    This report documents a review of the hydraulic and sediment-transport models developed by the City of Salisbury, Alcoa Power Generating, Inc., and the Federal Energy Regulatory Commission to address issues of flooding and sedimentation in the vicinity of Salisbury's water-supply intake 19.4 miles upstream from High Rock Dam. The objective of the review was to determine if the modeling results submitted by Salisbury clearly demonstrate that the presence of High Rock Dam has led to an increase in water levels at Salisbury facilities or, conversely, if the documents of Alcoa Power Generating, Inc., demonstrate that High Rock Dam has not had an effect on water levels at Salisbury facilities. No new data were collected as a part of the review, and the models developed by involved parties were not tested during the review. Some historical discharge-measurement notes and previously published reports were checked as part of the review. The one-dimensional hydraulic modeling results submitted by Alcoa Power Generating, Inc., did not assess the effects of changes in bathymetry on changes in flood levels at Salisbury's facilities because pre-impoundment conditions were not simulated. Hydraulic modeling performed by consultants for the City of Salisbury seems to indicate that both the presence of the dam in the absence of any post-impoundment sedimentation and changes in bathymetry between pre-impoundment and 1997 conditions have resulted in increased water levels relative to pre-impoundment conditions at Salisbury facilities on the Yadkin River for a fairly wide range of flows. The degree to which the dam and the changes in bathymetry have affected flood levels at the Salisbury facilities relative to pre-impoundment conditions is open to discussion because of uncertainty in topographic/bathymetric data and the absence of calibration and sensitivity testing of the hydraulic models. None of the three hydraulic models appears to have been calibrated to or tested against

  16. 76 FR 3516 - Drawbridge Operation Regulations; Merrimack River, Newburyport and Salisbury, MA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-20

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 117 [Docket No. USCG-2010-1134] Drawbridge Operation Regulations; Merrimack River, Newburyport and Salisbury, MA AGENCY: Coast Guard, DHS. ACTION: Notice of temporary deviation from regulations. SUMMARY: The Commander, First Coast Guard District, has...

  17. Dry Eye Disease following Refractive Surgery: A 12-Month Follow-Up of SMILE versus FS-LASIK in High Myopia

    PubMed Central

    Wang, Bingjie; Chu, Renyuan; Dai, Jinhui; Qu, Xiaomei; Zhou, Hao

    2015-01-01

    Purpose. To compare dry eye disease following SMILE versus FS-LASIK. Design. Prospective, nonrandomised, observational study. Patients. 90 patients undergoing refractive surgery for myopia were included. 47 eyes underwent SMILE and 43 eyes underwent FS-LASIK. Methods. Evaluation of dry eye disease was conducted preoperatively and at 1, 3, 6, and 12 months postoperatively, using the Salisbury Eye Evaluation Questionnaire (SEEQ) and TBUT. Results. TBUT reduced following SMILE at 1 and 3 months (p < 0.001) and at 1, 3, and 6 months following FS-LASIK (p < 0.001). TBUT was greater following SMILE than FS-LASIK at 3, 6, and 12 months (p < 0.001, p < 0.001, and p = 0.009, resp.). SEEQ scores increased (greater symptoms) following SMILE at 1 month (p < 0.001) and 3 months (p = 0.003) and at 1, 3, and 6 months following FS-LASIK (p < 0.001). SMILE produced lower SEEQ scores (fewer symptoms) than FS-LASIK at 1, 3, and 6 months (p < 0.001). Conclusion. SMILE produces less dry eye disease than FS-LASIK at 6 months postoperatively but demonstrates similar degrees of dry eye disease at 12 months. PMID:26649190

  18. In vivo Confocal Microscopy Evaluation of Meibomian Gland Dysfunction in Dry Eye Patients with Different Symptoms.

    PubMed

    Zhao, Hui; Chen, Jing-Yao; Wang, Yu-Qian; Lin, Zhi-Rong; Wang, Shen

    2016-11-05

    Dry eye patients suffer from all kinds of symptoms. Sometimes, the clinical signs evaluation does not disclose any obvious difference in routine examination; in vivo confocal microscopy (IVCM) is a powerful tool for ocular surface disease. This study aimed to clarify meibomian gland (MG) alterations in dry eye patients with different symptoms and to compare the findings using IVCM. A total of sixty patients were recruited, all subjected to Ocular Surface Disease Index (OSDI) and Salisbury Eye Evaluation Questionnaire (SEEQ), and questionnaires for the assessment of dry eye symptoms before clinical sign examinations were given to the patients. Finally, IVCM was applied to observe MG's structure. Statistical analysis was performed using the t-test, Mann-Whitney U-test and Spearman correlation analysis. The differences were statistically significant when P< 0.05. In the severe symptom group, OSDI and SEEQ scores were significantly higher (P< 0.05) compared with the mild symptoms group. All other clinical sign examinations had no statistical difference in the two groups (P> 0.05). However, all the IVCM-observed data showed that patients with severe symptoms had more significant fibrosis in MG (acinar unit area 691.87 ± 182.01 μm2 for the severe, 992.17 ± 170.84 μm2 for the mild; P< 0.05) and severer decrease in the size of MG acinar units than those observed in patients with mild symptoms (MG acinar unit density [MGAUD] 70.08 ± 18.78 glands/mm2, MG acinar unit longest diameter [MGALD] 51.50 ± 15.51 μm, MG acinar unit shortest diameter [MGASD] 20.30 ± 11.85 μm for the severe, MGAUD 89.53 ± 39.88 glands/mm2, MGALD 81.57 ± 21.14 μm, MGASD 42.37 ± 14.55 μm for the mild;P< 0.05). Dry eye symptoms were negatively correlated with MG confocal microscopic parameters and positively correlated with conjunctival inflammatory cells and Langerhans cells (P< 0.05). IVCM application provides a strong support to differentiate dry eye patients with different symptoms

  19. 76 FR 19096 - National Starch and Chemical Company, Salisbury, Rowan County, North Carolina; Notice of Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-06

    ... ENVIRONMENTAL PROTECTION AGENCY [Docket EPA-RO4-SFUND-2011-0278, FRL-9290-7] National Starch and... National Starch and Chemical Company Site located in Salisbury, Rowan County, North Carolina. In the...- SFUND-2011-0278 or Site name National Starch and Chemical Company Superfund Site by one of the following...

  20. Racial differences and other risk factors for incidence and progression of age-related macular degeneration: Salisbury Eye Evaluation (SEE) Project.

    PubMed

    Chang, Margaret A; Bressler, Susan B; Munoz, Beatriz; West, Sheila K

    2008-06-01

    To evaluate risk factors for the incidence and progression of age-related macular degeneration (AMD) in a racially heterogeneous, geriatric population. Subjects (n = 2240) aged 65 to 84 years underwent 2 examinations separated by 2 years, of which 1937 subjects (85%) were included in this report. Fundus photographs were performed at each examination and were graded by trained readers. Multivariate logistic regression models adjusted for age, sex, race, and clustering between eyes were used to evaluate risk factors for AMD incidence and progression. Smoking was a strong, dose-dependent, risk factor for progression from medium size drusen to large drusen or pigmentary abnormalities within the central 1500-microm macular zone. Smoking was also a strong risk factor for development of incident focal pigmentation within 3000 microm of the foveal center. White participants were significantly more likely than blacks to develop large drusen and focal pigmentation and to progress from medium- to large-sized drusen or pigment abnormalities within the central 1500 microm macular zone. However, whites did not have an increased risk of progression from large drusen or pigment abnormalities within the central 1500-microm perimacular zone to foveal GA or CNV when compared with blacks. Smoking and race are important risk factors for progression from medium to large drusen or to pigment abnormalities within the central 1500-microm macular zone. Limitations in the power of this study preclude assessment of the roles of smoking and race on the ultimate progression to foveal GA or CNV once central large drusen or pigment abnormalities are present.

  1. 78 FR 72001 - Amendment of Class D and E Airspace, and Establishment of Class E Airspace; Salisbury, MD

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-02

    ...'' W.) That airspace extending upward from the surface to and including 2,500 feet MSL [[Page 72002...] Salisbury-Ocean City Wicomico Regional Airport, MD (Lat. 38[deg]20'25'' N., long. 75[deg]30'34'' W.) That... (Lat. 38[deg]20'25'' N., long. 75[deg]30'34'' W.) That airspace extending upward from the surface...

  2. Florence Nightingale and the Salisbury incident.

    PubMed

    Palmer, I S

    1976-01-01

    Florence Nightingale's astute handling of mismanagement in Free Gifts Stores during the Crimean War underscored her administrative ability. Miss Nightingale went to Scutari ostensibly to nurse the British soldiers, and while there encountered innumerable instances of administrative and managerial ineffectiveness and difficulties. Among these were the problems in the accountability and deployment of supplies as well as the assignment and supervision of female personnel-an untried situation. The article identifies the misdirected organizational management which occasioned the introduction of women into British war nursing and the voluntary participation of the British citizenry in providing supplies and comfort for the Army. Through analysis of Miss Nightingale's and others' private correspondence, the problems of personnel management and supply distribution are brought into sharp focus. The interplay of policies and principles to which Miss Nightingale subscribed, the human frailty of one of her women, Miss Nightingale's illness, and the confusion and stress which characterized the Crimean War are discussed. The compassion, understanding, and rectitude as well as the human values to which Miss Nightingale subscribed in protecting a woman guilty of a breach of trust and felony and the troublesome slanderous attack to which Miss Nightingale was subjected at the instigation of her foes on the home front provide a background for the presentation of the Salisbury affair as an interesting aspect of historical research into the life of the Victorian heroine.

  3. Distributions of Benthic Foraminifera in the Salisbury Embayment before and after the PETM Onset

    NASA Astrophysics Data System (ADS)

    Range, M. M.; Robinson, M. M.

    2017-12-01

    Abrupt climatic perturbations associated with the onset of the Paleocene-Eocene Thermal Maximum (PETM) caused major disruptions to the shallow shelf ecology along the U.S. Atlantic Coastal Plain. Several studies examine the changes in benthic foraminiferal assemblages across the PETM in neritic sediments in New Jersey, Maryland, and Virginia and describe a hydrological and sedimentological paradigm shift that marks the Paleocene-Eocene boundary. In the Salisbury Embayment, a flexural low between the South Jersey High and the Norfolk Arch, this shift is seen in the transition between the upper Paleocene Aquia Formation and the lower Eocene Marlboro Clay. Here we map the abundance of seven benthic foraminifera species from five sites within the Salisbury Embayment from both the uppermost Aquia Formation and the lowermost Marlboro Clay. In addition to the benthic foraminiferal turnover at the PETM onset, we show a geographic distribution of species that highlights a past latitudinal biogeographic zonation not unlike what is found on the modern shelf in this region. Sites document a change in the abundance of species between the late Paleocene and early Eocene, showing a decrease in biodiversity of benthic species along the U.S. Atlantic Coast. Spatial extent of the different species also changed across the Paleocene-Eocene boundary. On the modern Atlantic shelf, a biogeographic zonation is due to the path of the Gulf Stream marking a boundary between relatively cold sea-surface temperatures to the north and warmer temperatures to the south, guided by the geomorphic expression of the mid-Atlantic coastline. During the Paleocene-Eocene transition, we suspect a similar boundary likely existed between the New Jersey sites and the Maryland and Virginia sites. We speculate that with the addition of more assemblage data, we will be able to partially reconstruct the geomorphic expression of the PETM coastline and/or the path of major coastal ocean currents.

  4. Evaluation of the Tobii EyeX Eye tracking controller and Matlab toolkit for research.

    PubMed

    Gibaldi, Agostino; Vanegas, Mauricio; Bex, Peter J; Maiello, Guido

    2017-06-01

    The Tobii Eyex Controller is a new low-cost binocular eye tracker marketed for integration in gaming and consumer applications. The manufacturers claim that the system was conceived for natural eye gaze interaction, does not require continuous recalibration, and allows moderate head movements. The Controller is provided with a SDK to foster the development of new eye tracking applications. We review the characteristics of the device for its possible use in scientific research. We develop and evaluate an open source Matlab Toolkit that can be employed to interface with the EyeX device for gaze recording in behavioral experiments. The Toolkit provides calibration procedures tailored to both binocular and monocular experiments, as well as procedures to evaluate other eye tracking devices. The observed performance of the EyeX (i.e. accuracy < 0.6°, precision < 0.25°, latency < 50 ms and sampling frequency ≈55 Hz), is sufficient for some classes of research application. The device can be successfully employed to measure fixation parameters, saccadic, smooth pursuit and vergence eye movements. However, the relatively low sampling rate and moderate precision limit the suitability of the EyeX for monitoring micro-saccadic eye movements or for real-time gaze-contingent stimulus control. For these applications, research grade, high-cost eye tracking technology may still be necessary. Therefore, despite its limitations with respect to high-end devices, the EyeX has the potential to further the dissemination of eye tracking technology to a broad audience, and could be a valuable asset in consumer and gaming applications as well as a subset of basic and clinical research settings.

  5. Comprehensive eye evaluation algorithm

    NASA Astrophysics Data System (ADS)

    Agurto, C.; Nemeth, S.; Zamora, G.; Vahtel, M.; Soliz, P.; Barriga, S.

    2016-03-01

    In recent years, several research groups have developed automatic algorithms to detect diabetic retinopathy (DR) in individuals with diabetes (DM), using digital retinal images. Studies have indicated that diabetics have 1.5 times the annual risk of developing primary open angle glaucoma (POAG) as do people without DM. Moreover, DM patients have 1.8 times the risk for age-related macular degeneration (AMD). Although numerous investigators are developing automatic DR detection algorithms, there have been few successful efforts to create an automatic algorithm that can detect other ocular diseases, such as POAG and AMD. Consequently, our aim in the current study was to develop a comprehensive eye evaluation algorithm that not only detects DR in retinal images, but also automatically identifies glaucoma suspects and AMD by integrating other personal medical information with the retinal features. The proposed system is fully automatic and provides the likelihood of each of the three eye disease. The system was evaluated in two datasets of 104 and 88 diabetic cases. For each eye, we used two non-mydriatic digital color fundus photographs (macula and optic disc centered) and, when available, information about age, duration of diabetes, cataracts, hypertension, gender, and laboratory data. Our results show that the combination of multimodal features can increase the AUC by up to 5%, 7%, and 8% in the detection of AMD, DR, and glaucoma respectively. Marked improvement was achieved when laboratory results were combined with retinal image features.

  6. The relationship between better-eye and integrated visual field mean deviation and visual disability.

    PubMed

    Arora, Karun S; Boland, Michael V; Friedman, David S; Jefferys, Joan L; West, Sheila K; Ramulu, Pradeep Y

    2013-12-01

    To determine the extent of difference between better-eye visual field (VF) mean deviation (MD) and integrated VF (IVF) MD among Salisbury Eye Evaluation (SEE) subjects and a larger group of glaucoma clinic subjects and to assess how those measures relate to objective and subjective measures of ability/performance in SEE subjects. Retrospective analysis of population- and clinic-based samples of adults. A total of 490 SEE and 7053 glaucoma clinic subjects with VF loss (MD ≤-3 decibels [dB] in at least 1 eye). Visual field testing was performed in each eye, and IVF MD was calculated. Differences between better-eye and IVF MD were calculated for SEE and clinic-based subjects. In SEE subjects with VF loss, models were constructed to compare the relative impact of better-eye and IVF MD on driving habits, mobility, self-reported vision-related function, and reading speed. Difference between better-eye and IVF MD and relationship of better-eye and IVF MD with performance measures. The median difference between better-eye and IVF MD was 0.41 dB (interquartile range [IQR], -0.21 to 1.04 dB) and 0.72 dB (IQR, 0.04-1.45 dB) for SEE subjects and clinic-based patients with glaucoma, respectively, with differences of ≥ 2 dB between the 2 MDs observed in 9% and 18% of the groups, respectively. Among SEE subjects with VF loss, both MDs demonstrated similar associations with multiple ability and performance metrics as judged by the presence/absence of a statistically significant association between the MD and the metric, the magnitude of observed associations (odds ratios, rate ratios, or regression coefficients associated with 5-dB decrements in MD), and the extent of variability in the metric explained by the model (R(2)). Similar associations of similar magnitude also were noted for the subgroup of subjects with glaucoma and subjects in whom better-eye and IVF MD differed by ≥ 2 dB. The IVF MD rarely differs from better-eye MD, and similar associations between VF loss and

  7. Objective evaluation of the visual acuity in human eyes

    NASA Astrophysics Data System (ADS)

    Rosales, M. A.; López-Olazagasti, E.; Ramírez-Zavaleta, G.; Varillas, G.; Tepichín, E.

    2009-08-01

    Traditionally, the quality of the human vision is evaluated by a subjective test in which the examiner asks the patient to read a series of characters of different sizes, located at a certain distance of the patient. Typically, we need to ensure a subtended angle of vision of 5 minutes, which implies an object of 8.8 mm high located at 6 meters (normal or 20/20 visual acuity). These characters constitute what is known as the Snellen chart, universally used to evaluate the spatial resolution of the human eyes. The mentioned process of identification of characters is carried out by means of the eye - brain system, giving an evaluation of the subjective visual performance. In this work we consider the eye as an isolated image-forming system, and show that it is possible to isolate the function of the eye from that of the brain in this process. By knowing the impulse response of the eye´s system we can obtain, in advance, the image of the Snellen chart simultaneously. From this information, we obtain the objective performance of the eye as the optical system under test. This type of results might help to detect anomalous situations of the human vision, like the so called "cerebral myopia".

  8. Preparation of Nonhuman Primate Eyes for Histological Evaluation After Retinal Gene Transfer.

    PubMed

    Bell, Peter; Yu, Hongwei; Kuntz, Leah; Ahonkhai, Omua; Tretiakova, Anna; Limberis, Maria P; Wilson, James M

    2018-06-01

    To evaluate gene therapy for retinal disorders, appropriate models of the human eye are needed. Nonhuman primate eyes offer significant advantages over rodent eyes. However, current preparation methods have limitations. Here, a protocol is described for histological processing of nonhuman primate eyes after gene transfer. The user dissects unfixed eyes, flattens the globe parts within filter paper, and performs formalin fixation and paraffin embedding. This method obviates the need for harsh fixatives, allowing subsequent immunostaining or in situ hybridization while preserving tissue integrity for histopathological evaluation. Moreover, the straight orientation of the retinal cell layers is ideal for image analysis.

  9. Evaluation of treatment for dry eye with 2-hydroxyestradiol using a dry eye rat model.

    PubMed

    Higuchi, Akihiro; Oonishi, Erina; Kawakita, Tetsuya; Tsubota, Kazuo

    2016-01-01

    2-hydroxy estradiol (2-OHE2) is a catechol derivative of 17β -Estradiol (E2) and it is synthesized from E2 catalyzed by cytochrome P4501A1. Previous studies reported that 2-OHE2 is a physiologic antioxidant in lipoproteins, liver microsomes, and the brain. Catechol derivatives show an anti-inflammatory effect through the inhibition of prostaglandin endoperoxide synthase (PGS) activity. Corneal erosion caused by dry eye is related to an increase in oxidative stress and inflammation in ocular surface cells. We investigated the therapeutic effects of 2-OHE2 on corneal damage caused by dry eye. Steroidal radical scavenging activity was confirmed through the electron spin resonance (ESR) method. PGS activity was measured using the COX Fluorescent Activity Assay Kit. To evaluate the effect of 2-OHE2 on the treatment for dry eye, 2-OHE2 was applied as an eye drop experiment using dry eye model rats. 2-OHE2 scavenged tyrosyl radical and possibly suppressed oxidative stress in corneal epithelial cells. In addition, 2-OHE2 inhibited PGS activity, and 2-OHE2 is probably a competitive inhibitor of PGS. Corneal PGS activity was upregulated in the dry eye group. Therefore, 2-OHE2 eye drops improved corneal erosion in dry eye model rats. 2-OHE2 is a candidate for the treatment of dry eye through the suppression of inflammation and oxidative stress in the cornea.

  10. Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators

    DTIC Science & Technology

    2017-07-07

    AFRL-RH-FS-TR-2017-0026 Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators Thomas K. Kuyk Peter A. Smith Solangia...34Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators" (AFRL-RH-FS-TR- 2017 - 0026 SHORTER.PATRI CK.D.1023156390 Digitally...SUBTITLE Flight Tasks and Metrics to Evaluate Laser Eye Protection in Flight Simulators 5a. CONTRACT NUMBER FA8650-14-D-6519 5b. GRANT NUMBER 5c

  11. Ocular Coherence Tomography in the Evaluation of Anterior Eye Injuries in Space Flight

    NASA Technical Reports Server (NTRS)

    Fer, Dan M.; Law, Jennifer; Wells, Julia

    2017-01-01

    While Ocular Coherence Tomography (OCT) is not a first-line modality to evaluate anterior eye structures terrestrially, it is a resource already available on the International Space Station (ISS) that can be used in medical contingencies that involve the anterior eye. With remote guidance and subject matter expert (SME) support from the ground, a minimally trained crewmember can now use OCT to evaluate anterior eye pathologies on orbit. OCT utilizes low-coherence interferometry to produce detailed cross-sectional and 3D images of the eye in real time. Terrestrially, it has been used to evaluate macular pathologies and glaucoma. Since 2013, OCT has been used onboard the ISS as one part of a suite of hardware to evaluate the Visual Impairment/Intracranial Pressure risk faced by astronauts, specifically assessing changes in the retina and choroid during space flight. The Anterior Segment Module (ASM), an add-on lens, was also flown for research studies, providing an opportunity to evaluate the anterior eye in real time if clinically indicated. Anterior eye pathologies that could be evaluated using OCT were identified. These included corneal abrasions and ulcers, scleritis, and acute angle closure glaucoma. A remote guider script was written to provide ground specialists with step-by-step instructions to guide ISS crewmembers, who do not get trained on the ASM, to evaluate the anterior eye. The instructions were tested on novice subjects and/or operators, whose feedback was incorporated iteratively. The final remote guider script was reviewed by SME optometrists and NASA flight surgeons. The novel application of OCT technology to space flight allows for the acquisition of objective data to diagnose anterior eye pathologies when other modalities are not available. This demonstrates the versatility of OCT and highlights the advantages of using existing hardware and remote guidance skills to expand clinical capabilities in space flight.

  12. Using Eye Trackers for Usability Evaluation of Health Information Technology: A Systematic Literature Review

    PubMed Central

    Yang, Yushi

    2015-01-01

    Background Eye-tracking technology has been used to measure human cognitive processes and has the potential to improve the usability of health information technology (HIT). However, it is still unclear how the eye-tracking method can be integrated with other traditional usability methodologies to achieve its full potential. Objective The objective of this study was to report on HIT evaluation studies that have used eye-tracker technology, and to envision the potential use of eye-tracking technology in future research. Methods We used four reference databases to initially identify 5248 related papers, which resulted in only 9 articles that met our inclusion criteria. Results Eye-tracking technology was useful in finding usability problems in many ways, but is still in its infancy for HIT usability evaluation. Limited types of HITs have been evaluated by eye trackers, and there has been a lack of evaluation research in natural settings. Conclusions More research should be done in natural settings to discover the real contextual-based usability problems of clinical and mobile HITs using eye-tracking technology with more standardized methodologies and guidance. PMID:27026079

  13. Evaluation of retinoic acid ophthalmic emulsion in dry eye.

    PubMed

    Selek, H; Unlü, N; Orhan, M; Irkeç, M

    2000-01-01

    An oil in water emulsion of 0.01% all-trans-retinoic acid (tretinoin) was prepared and clinically evaluated in dry eye patients. The ophthalmic emulsion consisted of 10% of arachis oil and 90% of the hydrogel of Carbopol 940. To evaluate retinoic acid emulsion clinically, a placebo-controlled, open-labeled, randomized study was performed with 22 dry-eye patients. Symptoms were recorded before and after the treatments. The Schirmer I test, measurement of tear film break-up time (BUT), rose Bengal and fluorescein staining of cornea and conjunctiva, and mucus fern test were done. Retinoic acid did not improve the dryness, photophobia and foreign body sensation more than placebo. Schirmer test and BUT were significantly improved by retinoic acid treatment. Corneal and conjunctival epithelium maintained their characteristics during the use of retinoic acid, as indicated by rose Bengal and fluorescein staining. Ophthalmic emulsion of retinoic acid can be suggested as a promising approach for the treatment of dry eye.

  14. FogEye UV Sensor System Evaluation : Phase II Report

    DOT National Transportation Integrated Search

    2003-12-01

    The primary objective of the FogEye Evaluation Program is to determine whether coupled ultra-violet sources and detectors may provide enhancements to safety on the airport surface. The results of this effort will be used to complete the evaluation of...

  15. The evaluation of eye pain with a normal ocular exam.

    PubMed

    Lee, Andrew G; Brazis, Paul W

    2003-12-01

    Eye pain with or without associated head or face pain is a common complaint to the ophthalmologist. The ocular exam may reveal the etiology (e.g., corneal disease, angle closure glaucoma) but typically the exam is normal. This paper reviews the evaluation and management of eye pain with a "normal" ocular exam, including: 1) subtle findings on ocular exam; 2) transient findings on exam, and 3) no abnormal ocular findings. Ophthalmologists should be aware of the various etiologies for eye pain and the specific and distinctive features that make the diagnosis.

  16. Evaluations of Corneas in Eyes with Isolated Iris Coloboma.

    PubMed

    Karatepe Haşhaş, Arzu Seyhan; Arifoğlu, Hasan Basri; Yüce, Yudum; Duru, Necati; Ulusoy, Döndü Melek; Zararsız, Gökmen

    2017-01-01

    We aimed to evaluate the differences in the corneas of eyes with isolated iris coloboma. This study was designed as a prospective study. Among patients who applied to our hospital within the last 3-year period, those with isolated iris coloboma in one eye and a completely normal contralateral eye were included in the study. In addition to a complete ophthalmologic examination, all patients were scanned by Pentacam Scheimpflug camera in the dark, and a corneal endothelium cell count was taken using a Topcon Specular Microscope. Data entered using SPSS software were then evaluated by paired t-test; p < 0.05 value was considered statistically significant. Nine patients, seven men and two women, with a mean age of 35.77 ± 22.50 (range 8-60) years, were included in the study. In comparison to normal eyes, the colobomatous eyes were statistically found to have lower keratometry values in diopters (43.82 ± 2.17, 44.46 ± 1.86; p = 0.040), a greater negative asphericity (Q value) (-0.38 ± 0.07, -0.22 ± 0.20; p = 0.042), increased corneal thickness (569.78 ± 25.42, 537.33 ± 27.36; p < 0.001), decreased anterior chamber depth (2.50 ± 0.32, 2.81 ± 0.50; p = 0.005), a shallower angle (30.51 ± 10.68, 35.29 ± 9.99; p = 0.057), higher best-fit sphere (BFS) values of the anterior and posterior corneal surfaces (7.88 ± 0.39, 7.67 ± 0.37; p = 0.001; 6.40 ± 0.26, 6.23 ± 0.19; p = 0.006), larger pupil diameter (3.48 ± 0.49, 2.80 ± 0.34; p = 0.001), smaller horizontal corneal diameter (HCD) (11.06 ± 0.42; 11.26 ± 0.45; p = 0.009), and higher value of endothelial cell density (ECD) (3161 ± 431; 2923 ± 590; p = 0.031). We have determined that a number of factors such as keratometry values, particularly of the corneal endothelium, are different from those of normal eyes. These differences should be taken into account in the follow-up and treatment of eyes with iris coloboma.

  17. Occult intraocular trauma: evaluation of the eye in an austere environment.

    PubMed

    Sweet, Patrick H

    2013-03-01

    Physicians deployed to austere environments often encounter the challenge of needing to make clinical decisions based upon rudimentary history and physical examination. These skills, however, can be difficult for many to rely on, with the many subtleties of examining the eye, when they are normally accustomed to relying on sophisticated modalities to establish diagnosis. This case is a model for evaluating eye trauma in an austere or hostile environment. A 25-year-old male U.S. Marine was fired upon at a Mexican Army checkpoint where he sustained glass shrapnel injuries, the most serious being to his right eye. He was taken from a detention facility to a Mexican hospital, where he was evaluated and given the diagnosis of corneal laceration. Twelve hours later, a U.S. Navy physician arrived to evaluate the patient; he was allowed limited access to the patient. His ophthalmologic examination revealed a closed corneal laceration on the right eye, worse than 20/800 vision, absent red reflex, and obscured funduscopic examination. These findings made it impossible to rule out globe penetration. The patient was released 48 h later to a U.S. Naval Hospital, where intraocular foreign bodies were confirmed by imaging and he was taken to emergency surgery. This case illustrates that even under austere conditions, a focused history and evaluation can reveal the likelihood of occult intraocular foreign body, thereby triaging the patient for emergency surgery. Published by Elsevier Inc.

  18. Pathological evaluation of postmortem human eyes implanted with a new single-piece hydrophobic acrylic lens.

    PubMed

    Izak, Andrea M; Werner, Liliana; Pandey, Suresh K; Apple, David J

    2004-07-01

    To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.

  19. National Program for Inspection of Non-Federal Dams. Sucker Brook Dam (VT 00212), Richelieu River Basin, Town of Salisbury, Addison County, Vermont. Phase I Inspection Report.

    DTIC Science & Technology

    1980-02-01

    BENNINGTON STATE OF VERMONT APPROX. SCALE IN MILES SUCKER BROOK DAM LOCATION MAP GORDON E AINSWORTH & ASSOCIATES INC Fviil 20 SU6ARLOAF STSUHDEFEDMASS...New Hampshire and Vermont - Water Year 1977", USGS Water-Data Report NH-Vf-77-l, U.S. Geologi - 0 cal Survey, Boston, Ma., 1978. 20. "Climatological...34’.’ -_’_,’’- ".’’° , ’J LrLi . m""_"’"L % " , , " °. • .. RICHELIEU RIVER BASIN TOWN OF SALISBURY ADDISON COUNTY, VERMONT 0o (0 Ln SUCKER

  20. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    PubMed

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential

  1. Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings

    PubMed Central

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential

  2. Conjunctival impression cytology evaluation of patients with dry eye disease using scleral contact lenses.

    PubMed

    Weber, Sarah La Porta; Hazarbassanov, Rossen Mihaylov; Nasaré, Alex; Gomes, José Álvaro Pereira; Hofling-Lima, Ana Luisa

    2017-06-01

    To evaluate conjunctival impression cytology and HLADR expression changes after wearing scleral contact lenses (ScCLs) for moderate to severe dry eye disease (DED). Prospective interventional case series. Forty-one eyes from 25 patients with moderate to severe DED were evaluated for Esclera ScCL treatment. Best-corrected visual acuity (BCVA) and slit-lamp findings were assessed. Impression cytology specimens were obtained from DED patients at the baseline and after wearing ScCLs for 12 months. The impression cytology specimens were analyzed using morphological results score, and HLA-DR positive cells were detected and quantified. The values were compared to assess the IC changes after wearing ScCLs. Forty-one eyes from 25 patients were fitted with ScCLs to manage DED. The underlying diseases were Stevens-Johnson syndrome (22 eyes), Sjogren's syndrome (11 eyes), graft-versus-host disease (2 eyes), dry eye after keratomileusis (2 eyes) and undifferentiated ocular surface disease (4 eyes). The HE-PAS impression cytology score did not differ significantly before and after wearing ScCLs for 12 months in DED patients (p>0.05). The percentage of eyes expressing the HLA-DR antigen in the temporal conjunctiva after wearing ScCL for 12 months significantly increased in patients with Sjogren's syndrome (11.11% to 66.66%; p=0.0498). In groups with Stevens Johnson syndrome and other ocular surface disorders, we did not observe statistically significant differences (p>0.05). The ScCLs did not change the parameters used to evaluate inflammatory processes, which were measured using conjunctival impression cytology and HLA-DR expression, except in Sjogren syndrome, in which there was an unexpected increase in HLA expression. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. The Bull's-Eye Values Survey: A Psychometric Evaluation

    ERIC Educational Resources Information Center

    Lundgren, Tobias; Luoma, Jason B.; Dahl, JoAnne; Strosahl, Kirk; Melin, Lennart

    2012-01-01

    Two studies were conducted to develop and evaluate an instrument intended to identify and measure personal values, values attainment, and persistence in the face of barriers. Study 1 describes a content validity approach to the construction and preliminary validation of the Bull's Eye Values Survey (BEVS), using a sample of institutionalized…

  4. Standard eye exam

    MedlinePlus

    Standard ophthalmic exam; Routine eye examination; Eye exam - standard; Annual eye exam ... Comprehensive adult medical eye evaluation preferred practice pattern guidelines. Ophthalmology . 2016;123(1):209-236. PMID: 26581558 ...

  5. Identifying and assessing strategies for evaluating the impact of mobile eye health units on health outcomes.

    PubMed

    Fu, Shiwan; Turner, Angus; Tan, Irene; Muir, Josephine

    2017-12-01

    To identify and assess strategies for evaluating the impact of mobile eye health units on health outcomes. Systematic literature review. Worldwide. Peer-reviewed journal articles that included the use of a mobile eye health unit. Journal articles were included if outcome measures reflected an assessment of the impact of a mobile eye health unit on health outcomes. Six studies were identified with mobile services offering diabetic retinopathy screening (three studies), optometric services (two studies) and orthoptic services (one study). This review identified and assessed strategies in existing literature used to evaluate the impact of mobile eye health units on health outcomes. Studies included in this review used patient outcomes (i.e. disease detection, vision impairment, treatment compliance) and/or service delivery outcomes (i.e. cost per attendance, hospital transport use, inappropriate referrals, time from diabetic retinopathy photography to treatment) to evaluate the impact of mobile eye health units. Limitations include difficulty proving causation of specific outcome measures and the overall shortage of impact evaluation studies. Variation in geographical location, service population and nature of eye care providers limits broad application. © 2017 National Rural Health Alliance Inc.

  6. [Evaluation of NAAGA efficacy in dry eye syndrome].

    PubMed

    Brignole-Baudouin, F; Robert, P-Y; Creuzot-Garcher, C; Olmiere, C; Delval, L; Baudouin, C

    2009-11-01

    The aim of this study was to assess the efficacy of Naabak((R)) eyedrops in reducing inflammation in dry eye syndrome. This pilot, multicenter, randomized, double-blind, parallel study was carried out in adult patients suffering from moderate dry eye syndrome. Patients were treated for three months with preservative-free NAAGA (Naabak((R))) or with sodium chloride 0.9% without preservative (Larmabak(R)). They received the treatment four to six times a day during the 1(st) month and three to four times a day during the 2(nd) and 3(rd) months. At each visit (D28 and D84), clinical tests were performed as well as a biological evaluation of HLA-DR and MUC5AC expression on conjunctival imprints using flow cytometry. After three months of treatment, the ocular surface symptoms and overall discomfort were improved in patients treated with Naabak(R) and in those treated with Larmabak(R) with no significant difference between the groups. Cytological impression showed a significant decrease in the expression of inflammatory markers, notably antigen HLA-DR, in the Naabak(R) group. This study confirms the anti-inflammatory property of preservative-free NAAGA (Naabak(R)) in the context of dry eye syndrome with a similar clinical efficacy compared to sodium chloride solution (Larmabak(R)). Naabak(R) could present an additional advantage compared to artificial tears and could be indicated in the treatment of moderate inflammatory dry eye syndrome.

  7. Evaluation of active and passive transport processes in corneas extracted from preserved rabbit eyes.

    PubMed

    Majumdar, Soumyajit; Hingorani, Tushar; Srirangam, Ramesh

    2010-04-01

    In vitro transcorneal permeability studies are an important screening tool in drug development. The objective of this research is to examine the feasibility of using corneas isolated from preserved rabbit eyes as a model for permeability evaluation. Eyes from male New Zealand White rabbits were used immediately or were stored overnight in phosphate-buffered saline (PBS) or Hanks balanced salt solution (HBSS) over wet ice. Integrity of isolated corneas was evaluated by measuring the TEER and by determining the permeability of paracellular and transcellular markers. Active transport was assessed by measuring transcorneal permeability of selected amino acids. Esterase activity was estimated using p-nitrophenyl assay. In all cases, corneas from freshly enucleated eyes were compared to those isolated from the day-old preserved eyes. Transcellular and paracellular passive diffusion was not affected by the storage medium and observed to be similar in the fresh and preserved eye models. However, amino acid transporters demonstrated lower functional activity in corneas excised from eyes preserved in PBS. Moreover, preserved eyes displayed almost 1.5-fold lower esterase activity in the corneal tissue. Thus, corneas isolated from day-old eyes, preserved in HBSS, closely mimics freshly excised rabbit corneas in terms of both active and passive transport characteristics but possesses slightly reduced enzymatic activity. 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  8. ENLARGEMENT OF FOVEAL AVASCULAR ZONE IN DIABETIC EYES EVALUATED BY EN FACE OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY.

    PubMed

    Takase, Noriaki; Nozaki, Miho; Kato, Aki; Ozeki, Hironori; Yoshida, Munenori; Ogura, Yuichiro

    2015-11-01

    To evaluate the area of the foveal avascular zone (FAZ) detected by en face OCTA (AngioVue, Avanti OCT; Optovue) in healthy and diabetic eyes. Retrospective chart review of patients who underwent fundus examination including en face OCTA. Eyes with proliferative diabetic retinopathy and history of laser photocoagulation were excluded. The FAZ area in the superficial and deep plexus layers were measured and evaluated using ImageJ software. The FAZ area in the superficial layer was 0.25 ± 0.06 mm² in healthy eyes (n = 19), whereas it was 0.37 ± 0.07 mm² in diabetic eyes without retinopathy (n = 24) and 0.38 ± 0.11 mm² in eyes with diabetic retinopathy (n = 20). Diabetic eyes showed statistically significant FAZ enlargement compared with healthy eyes, regardless of the presence of retinopathy (P < 0.01). The FAZ area in the deep plexus layer was also significantly larger in diabetic eyes than in healthy eyes (P < 0.01). Our data suggest that diabetic eyes show retinal microcirculation impairment in the macula even before retinopathy develops. En face OCTA is a useful noninvasive screening tool for detecting early microcirculatory disturbance in patients with diabetes.

  9. Dosimetric evaluation of lead and tungsten eye shields in electron beam treatment.

    PubMed

    Shiu, A S; Tung, S S; Gastorf, R J; Hogstrom, K R; Morrison, W H; Peters, L J

    1996-06-01

    The purpose of this study is to report that commercially available eye shields (designed for orthovoltage x-rays) are inadequate to protect the ocular structures from penetrating electrons for electron beam energies equal to or greater than 6 MeV. Therefore, a prototype medium size tungsten eye shield was designed and fabricated. The advantages of the tungsten eye shield over lead are discussed. Electron beams (6-9 MeV) are often used to irradiate eyelid tumors to curative doses. Eye shields can be placed under the eyelids to protect the globe. Film and thermoluminescent dosimeters (TLDs) were used within a specially constructed polystyrene eye phantom to determine the effectiveness of various commercially available internal eye shields (designed for orthovoltage x-rays). The same procedures were used to evaluate a prototype medium size tungsten eye shield (2.8 mm thick), which was designed and fabricated for protection of the globe from penetrating electrons for electron beam energy equal to 9 MeV. A mini-TLD was used to measure the dose enhancement due to electrons backscattered off the tungsten eye shield, both with or without a dental acrylic coating that is required to reduce discomfort, permit sterilization of the shield, and reduce the dose contribution from backscattered electrons. Transmission of a 6 MeV electron beam through a 1.7 mm thick lead eye shield was found to be 50% on the surface (cornea) of the phantom and 27% at a depth of 6 mm (lens). The thickness of lead required to stop 6-9 MeV electron beams is impractical. In place of lead, a prototype medium size tungsten eye shield was made. For 6 to 9 MeV electrons, the doses measured on the surface (cornea) and at 6 mm (lens) and 21 mm (retina) depths were all less than 5% of the maximum dose of the open field (4 x 4 cm). Electrons backscattered off a tungsten eye shield without acrylic coating increased the lid dose from 85 to 123% at 6 MeV and 87 to 119% at 9 MeV. For the tungsten eye shield coated

  10. Evaluation of Dry Eye and Meibomian Gland Dysfunction in Teenagers with Myopia through Noninvasive Keratograph

    PubMed Central

    Wang, Xiu; Lu, Xiaoxiao; Yang, Jun; Wei, Ruihua; Yang, Liyuan; Zhao, Shaozhen; Wang, Xilian

    2016-01-01

    Purpose. This study aims to evaluate dry eye and ocular surface conditions of myopic teenagers by using questionnaire and clinical examinations. Methods. A total of 496 eyes from 248 myopic teenagers (7–18 years old) were studied. We administered Ocular Surface Disease Index (OSDI) questionnaire, slit-lamp examination, and Keratograph 5M. The patients were divided into 2 groups based on OSDI dry eye standard, and their ocular surfaces and meibomian gland conditions were evaluated. Results. The tear meniscus heights of the dry eye and normal groups were in normal range. Corneal fluorescein scores were significantly higher whereas noninvasive break-up time was dramatically shorter in the dry eye group than in the normal group. All three meibomian gland dysfunction parameters (i.e., meibomian gland orifice scores, meibomian gland secretion scores, and meibomian gland dropout scores) of the dry eye group were significantly higher than those of the normal group (P < 0.0001). Conclusions. The prevalence of dry eye in myopic teenagers is 18.95%. Meibomian gland dysfunction plays an important role in dry eye in myopic teenagers. The Keratograph 5M appears to provide an effective noninvasive method for assessing ocular surface situation of myopic teenagers. PMID:26881059

  11. Ex vivo evaluation of Tono-Pen and pneumotonometry in cat eyes.

    PubMed

    Stoiber, Josef; Fernandez, Viviana; Lamar, Peggy D; Hitzl, Wolfgang; Fantes, Francisco; Parel, Jean-Marie

    2006-01-01

    To evaluate the validity and intraobserver reliability of intraocular pressure (IOP) measurements with both pneumotonometry and the Tono-Pen in a closed ex vivo system in cat eyes. IOP was increased step by step in 5 enucleated cat eyes, while taking IOP measurements with the Tono-Pen and pneumotonometry. The outcomes were compared to readings of a digital manometer simultaneously measuring the actual pressure in the anterior chamber. Pneumotonometry overestimated IOP below 15 mm Hg and underestimated pressures above 20 mm Hg. Tono-Pen tonometry considerably underestimated IOP over the whole spectrum in all of the eyes tested. The pneumotonometer was identified as the more valid and reliable instrument for cat eyes. Both tonometers are clinically useful tools to assess IOP for glaucoma studies using a cat animal model. However, one has to consider underestimation of IOP in the upper ranges. A correction formula can be used to calculate the actual IOP.

  12. Evaluation of a community-based participatory farmworker eye health intervention in the "black dirt" region of New York state.

    PubMed

    Earle-Richardson, Giulia; Wyckoff, Lynae; Carrasquillo, Marilyn; Scribani, Melissa; Jenkins, Paul; May, John

    2014-09-01

    Eye irritation is a constant hazard for migrant and seasonal farmworkers, but there are few studies of the problem or how to address it. Researchers evaluated the effect of a community-based participatory eye health intervention on farmworker eye symptoms in the Hudson Valley, NY. A randomized pre-post intervention with 2, 4-week follow-up periods was implemented with a sample of 97 farmworkers. Five eye symptoms were measured, along with utilization of protective eyewear and eye drops. Leading baseline eye symptoms were redness (49%), blurred vision (43%), itching (43%), and eye pain (29%). Significant reductions in eye pain (P = 0.009), and non-significant reductions in redness were observed for the intervention group while controls experienced increases in both. The intervention was effective in significantly reducing eye pain, and to a lesser extent, redness. Future eyewear promotion programs should offer a range of eye wear, tailor offerings to local climate and tasks, evaluate eyewear durability, and include eye drops. © 2014 Wiley Periodicals, Inc.

  13. Aircrew Eye/Respiratory Protection (AERP): 16-Hour Extended Wear Evaluation of Chemical Protective Equipment.

    DTIC Science & Technology

    1994-02-01

    Respiratory Protection (AERP) and associated clothing and equipment. Two subjects each carried out simulated tanker/transport and fighter/attack scenarios. No...AD A277 288 N•.• AL-TP-1 993-0014 ý’vI~~I~ 11~ II~I AIRCREW EYE/ RESPIRATORY PROTECTION (AERP): 16-HOUR EXTENDED WEAR EVALUATION OF R CHEMICAL...S. FUNDING NUMBERS ’Aircrew Eye/ Respiratory Protection (AERP): 16-Hour Extended PE - 62202F Wear Evaluation of Chemical Protective Equipment PR

  14. Evaluating anesthetic protocols for functional blood flow imaging in the rat eye

    NASA Astrophysics Data System (ADS)

    Moult, Eric M.; Choi, WooJhon; Boas, David A.; Baumann, Bernhard; Clermont, Allen C.; Feener, Edward P.; Fujimoto, James G.

    2017-01-01

    The purpose of this study is to evaluate the suitability of five different anesthetic protocols (isoflurane, isoflurane-xylazine, pentobarbital, ketamine-xylazine, and ketamine-xylazine-vecuronium) for functional blood flow imaging in the rat eye. Total retinal blood flow was measured at a series of time points using an ultrahigh-speed Doppler OCT system. Additionally, each anesthetic protocol was qualitatively evaluated according to the following criteria: (1) time-stability of blood flow, (2) overall rate of blood flow, (3) ocular immobilization, and (4) simplicity. We observed that different anesthetic protocols produced markedly different blood flows. Different anesthetic protocols also varied with respect to the four evaluated criteria. These findings suggest that the choice of anesthetic protocol should be carefully considered when designing and interpreting functional blood flow studies in the rat eye.

  15. In Vivo Confocal Microscopic Evaluation of Corneal Langerhans Cells in Dry Eye Patients§

    PubMed Central

    Machetta, Federica; Fea, Antonio M; Actis, Alessandro G; de Sanctis, Ugo; Dalmasso, Paola; Grignolo, Federico M

    2014-01-01

    Purpose. To assess inflammatory involvement of cornea in dry eye by means of confocal microscopy, evaluating the presence and distribution of Langherans cells (LCs). Methods: 98 eyes of 49 subjects were enrolled: 18 subjects affected by Sjögren Syndrome Dry Eye (SSDE), 17 with Non-Sjögren Syndrome Dry Eye (NSSDE), 14 healthy volunteeers. Dry eye symptoms, tear film, ocular surface damage and corneal confocal microscopy were analized. Results: A significant increase of LCs density was observed at sub-basal nerve plexus (SSDE = 79 cells/mm2 andNDE = 22 cells/mm2; p = 0,0031) and sub-epithelial nerve plexus (SSDE = 38 cells/mm2 and NDE = 3 cells/mm2; p = 0,0169) in central cornea of SSDE group. An increased number of LCs from the center to the periphery of the cornea was observed, significant only in healthy volunteers group. In dry eye patients there was an increase in LCs density in both peripheral and central cornea with a significant difference between NDE (14,66 cells/mm2) and SSDE (56,66 cells/mm2) only in central cornea (p = 0,0028). In SSDE group, mean density of LCs in central cornea results also superior to NSSDE group (29,33 cells/mm2). There was no correlation between LCs density and dry eye symptoms, tear film deficiency and ocular surface damage. Conclusion: This study demonstrates the activation of an inflammatory and immunological reaction in cornea of NSSDE and SSDE patients. Confocal microscopy can be an important diagnostic tool in evaluation and follow-up of dry eye disease. PMID:25317216

  16. Sea-floor texture and physiographic zones of the inner continental shelf from Salisbury to Nahant, Massachusetts, including the Merrimack Embayment and Western Massachusetts Bay

    USGS Publications Warehouse

    Pendleton, Elizabeth E.; Barnhardt, Walter A.; Baldwin, Wayne E.; Foster, David S.; Schwab, William C.; Andrews, Brian D.; Ackerman, Seth D.

    2015-10-26

    A series of maps that describe the distribution and texture of sea-floor sediments and physiographic zones of Massachusetts State waters from Nahant to Salisbury, Massachusetts, including western Massachusetts Bay, have been produced by using high-resolution geophysical data (interferometric and multibeam swath bathymetry, lidar bathymetry, backscatter intensity, and seismic reflection profiles), sediment samples, and bottom photographs. These interpretations are intended to aid statewide efforts to inventory and manage coastal and marine resources, link with existing data interpretations, and provide information for research focused on coastal evolution and environmental change. Marine geologic mapping of the inner continental shelf of Massachusetts is a statewide cooperative effort of the U.S. Geological Survey and the Massachusetts Office of Coastal Zone Management.

  17. Evaluation of eye metrics as a detector of fatigue.

    PubMed

    McKinley, R Andy; McIntire, Lindsey K; Schmidt, Regina; Repperger, Daniel W; Caldwell, John A

    2011-08-01

    This study evaluated oculometrics as a detector of fatigue in Air Force-relevant tasks after sleep deprivation. Using the metrics of total eye closure duration (PERCLOS) and approximate entropy (ApEn), the relation between these eye metrics and fatigue-induced performance decrements was investigated. One damaging effect to the successful outcome of operational military missions is that attributed to sleep deprivation-induced fatigue. Consequently, there is interest in the development of reliable monitoring devices that can assess when an operator is overly fatigued. Ten civilian participants volunteered to serve in this study. Each was trained on three performance tasks: target identification, unmanned aerial vehicle landing, and the psychomotor vigilance task (PVT). Experimental testing began after 14 hr awake and continued every 2 hr until 28 hr of sleep deprivation was reached. Performance on the PVT and target identification tasks declined significantly as the level of sleep deprivation increased.These performance declines were paralleled more closely by changes in the ApEn compared to the PERCLOS measure. The results provide evidence that the ApEn eye metric can be used to detect fatigue in relevant military aviation tasks. Military and commercial operators could benefit from an alertness monitoring device.

  18. Conjunctival impression cytology versus routine tear function tests for dry eye evaluation in contact lens wearers.

    PubMed

    Kumar, Prachi; Bhargava, Rahul; Arora, Yogesh C; Kaushal, Sidharth; Kumar, Manjushri

    2015-01-01

    Prolonged contact lens wear is often accompanied by dryness of the eyes. The aim of this study was to compare conjunctival impression cytology (CIC) and tear film tests such as tear film break up time (TBUT) and Schirmer test for dry eye evaluation in contact lens wearers and measure their correlation with dry eye symptoms. A case control study was done at three referral eye centers. The eyes of 230 contact lens users were compared to 250 eyes of age- and sex-matched controls. Participants were recruited based on their response to a questionnaire of dry eye symptoms, (Dry Eye Scoring System, DESS(©)) and measurements of TBUT, Schirmer test, and CIC was done. A correlation analysis between symptom severity and tear film tests was performed. Pearson's coefficient, R(2) > 0.5 was considered significant. As compared to controls (r (2) = 0.010), Nelson grade correlated significantly with dry eye symptoms (r (2) = 0.765), among cases. However, there was moderate correlation between dry eye symptoms, Schirmer test, and TBUT (r (2) = 0.557 and 0.530, respectively) among cases and a weak correlation among controls (r (2) = 0.130 and 0.054, respectively). The sensitivity of TBUT was 86.4%, specificity was 82.4%, positive likelihood ratio (LR) was 4.50 [95% confidence interval (CI) 3.46-5.85)], and negative LR was 0.09. The sensitivity of the Schirmer test was 48.2%, specificity 88%, LR 2.12 (95% CI 1.48-2.96), and negative LR 0.83. CIC correlates better than Schirmer and TBUT with dry eye symptoms. It may be the most appropriate test for dry-eye evaluation in contact lens wearers.

  19. Shallow marine response to global climate change during the Paleocene-Eocene Thermal Maximum, Salisbury Embayment, USA

    USGS Publications Warehouse

    Self-Trail, Jean; Robinson, Marci M.; Bralower, Timothy J.; Sessa, Jocelyn A.; Hajek, Elizabeth A.; Kump, Lee R.; Trampush, Sheila M.; Willard, Debra A.; Edwards, Lucy E.; Powars, David S.; Wandless, Gregory A.

    2017-01-01

    The Paleocene-Eocene Thermal Maximum (PETM) was an interval of extreme warmth that caused disruption of marine and terrestrial ecosystems on a global scale. Here we examine the sediments, flora, and fauna from an expanded section at Mattawoman Creek-Billingsley Road (MCBR) in Maryland and explore the impact of warming at a nearshore shallow marine (30–100 m water depth) site in the Salisbury Embayment. Observations indicate that at the onset of the PETM, the site abruptly shifted from an open marine to prodelta setting with increased terrestrial and fresh water input. Changes in microfossil biota suggest stratification of the water column and low-oxygen bottom water conditions in the earliest Eocene. Formation of authigenic carbonate through microbial diagenesis produced an unusually large bulk carbon isotope shift, while the magnitude of the corresponding signal from benthic foraminifera is similar to that at other marine sites. This proves that the landward increase in the magnitude of the carbon isotope excursion measured in bulk sediment is not due to a near instantaneous release of 12C-enriched CO2. We conclude that the MCBR site records nearshore marine response to global climate change that can be used as an analog for modern coastal response to global warming.

  20. Shallow marine response to global climate change during the Paleocene-Eocene Thermal Maximum, Salisbury Embayment, USA

    NASA Astrophysics Data System (ADS)

    Self-Trail, Jean M.; Robinson, Marci M.; Bralower, Timothy J.; Sessa, Jocelyn A.; Hajek, Elizabeth A.; Kump, Lee R.; Trampush, Sheila M.; Willard, Debra A.; Edwards, Lucy E.; Powars, David S.; Wandless, Gregory A.

    2017-07-01

    The Paleocene-Eocene Thermal Maximum (PETM) was an interval of extreme warmth that caused disruption of marine and terrestrial ecosystems on a global scale. Here we examine the sediments, flora, and fauna from an expanded section at Mattawoman Creek-Billingsley Road (MCBR) in Maryland and explore the impact of warming at a nearshore shallow marine (30-100 m water depth) site in the Salisbury Embayment. Observations indicate that at the onset of the PETM, the site abruptly shifted from an open marine to prodelta setting with increased terrestrial and fresh water input. Changes in microfossil biota suggest stratification of the water column and low-oxygen bottom water conditions in the earliest Eocene. Formation of authigenic carbonate through microbial diagenesis produced an unusually large bulk carbon isotope shift, while the magnitude of the corresponding signal from benthic foraminifera is similar to that at other marine sites. This proves that the landward increase in the magnitude of the carbon isotope excursion measured in bulk sediment is not due to a near instantaneous release of 12C-enriched CO2. We conclude that the MCBR site records nearshore marine response to global climate change that can be used as an analog for modern coastal response to global warming.

  1. The effect of image sharpness on quantitative eye movement data and on image quality evaluation while viewing natural images

    NASA Astrophysics Data System (ADS)

    Vuori, Tero; Olkkonen, Maria

    2006-01-01

    The aim of the study is to test both customer image quality rating (subjective image quality) and physical measurement of user behavior (eye movements tracking) to find customer satisfaction differences in imaging technologies. Methodological aim is to find out whether eye movements could be quantitatively used in image quality preference studies. In general, we want to map objective or physically measurable image quality to subjective evaluations and eye movement data. We conducted a series of image quality tests, in which the test subjects evaluated image quality while we recorded their eye movements. Results show that eye movement parameters consistently change according to the instructions given to the user, and according to physical image quality, e.g. saccade duration increased with increasing blur. Results indicate that eye movement tracking could be used to differentiate image quality evaluation strategies that the users have. Results also show that eye movements would help mapping between technological and subjective image quality. Furthermore, these results give some empirical emphasis to top-down perception processes in image quality perception and evaluation by showing differences between perceptual processes in situations when cognitive task varies.

  2. 77 FR 41406 - Evaluation of In Vitro Tests for Identifying Eye Injury Hazard Potential of Chemicals and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Evaluation of In Vitro Tests for Identifying Eye Injury...-animal testing strategies proposed for identifying eye injury hazard potential of chemicals and products... Panel and submission of data from substances tested in in vitro tests for identifying eye injury hazard...

  3. Assessing the Potential Use of Eye-Tracking Triangulation for Evaluating the Usability of an Online Diabetes Exercise System.

    PubMed

    Schaarup, Clara; Hartvigsen, Gunnar; Larsen, Lars Bo; Tan, Zheng-Hua; Årsand, Eirik; Hejlesen, Ole Kristian

    2015-01-01

    The Online Diabetes Exercise System was developed to motivate people with Type 2 diabetes to do a 25 minutes low-volume high-intensity interval training program. In a previous multi-method evaluation of the system, several usability issues were identified and corrected. Despite the thorough testing, it was unclear whether all usability problems had been identified using the multi-method evaluation. Our hypothesis was that adding the eye-tracking triangulation to the multi-method evaluation would increase the accuracy and completeness when testing the usability of the system. The study design was an Eye-tracking Triangulation; conventional eye-tracking with predefined tasks followed by The Post-Experience Eye-Tracked Protocol (PEEP). Six Areas of Interests were the basis for the PEEP-session. The eye-tracking triangulation gave objective and subjective results, which are believed to be highly relevant for designing, implementing, evaluating and optimizing systems in the field of health informatics. Future work should include testing the method on a larger and more representative group of users and apply the method on different system types.

  4. Evaluation of Eye Irritation Potential of Solid Substance with New 3D Reconstructed Human Cornea Model, MCTT HCETM

    PubMed Central

    Jang, Won-hee; Jung, Kyoung-mi; Yang, Hye-ri; Lee, Miri; Jung, Haeng-Sun; Lee, Su-Hyon; Park, Miyoung; Lim, Kyung-Min

    2015-01-01

    The eye irritation potential of drug candidates or pharmaceutical ingredients should be evaluated if there is a possibility of ocular exposure. Traditionally, the ocular irritation has been evaluated by the rabbit Draize test. However, rabbit eyes are more sensitive to irritants than human eyes, therefore substantial level of false positives are unavoidable. To resolve this species difference, several three-dimensional human corneal epithelial (HCE) models have been developed as alternative eye irritation test methods. Recently, we introduced a new HCE model, MCTT HCETM which is reconstructed with non-transformed human corneal cells from limbal tissues. Here, we examined if MCTT HCETM can be employed to evaluate eye irritation potential of solid substances. Through optimization of washing method and exposure time, treatment time was established as 10 min and washing procedure was set up as 4 times of washing with 10 mL of PBS and shaking in 30 mL of PBS in a beaker. With the established eye irritation test protocol, 11 solid substances (5 non-irritants, 6 irritants) were evaluated which demonstrated an excellent predictive capacity (100% accuracy, 100% specificity and 100% sensitivity). We also compared the performance of our test method with rabbit Draize test results and in vitro cytotoxicity test with 2D human corneal epithelial cell lines. PMID:26157556

  5. Optimization and validation of an existing, surgical and robust dry eye rat model for the evaluation of therapeutic compounds.

    PubMed

    Joossen, Cedric; Lanckacker, Ellen; Zakaria, Nadia; Koppen, Carina; Joossens, Jurgen; Cools, Nathalie; De Meester, Ingrid; Lambeir, Anne-Marie; Delputte, Peter; Maes, Louis; Cos, Paul

    2016-05-01

    The aim of this research was to optimize and validate an animal model for dry eye, adopting clinically relevant evaluation parameters. Dry eye was induced in female Wistar rats by surgical removal of the exorbital lacrimal gland. The clinical manifestations of dry eye were evaluated by tear volume measurements, corneal fluorescein staining, cytokine measurements in tear fluid, MMP-9 mRNA expression and CD3(+) cell infiltration in the conjunctiva. The animal model was validated by treatment with Restasis(®) (4 weeks) and commercial dexamethasone eye drops (2 weeks). Removal of the exorbital lacrimal gland resulted in 50% decrease in tear volume and a gradual increase in corneal fluorescein staining. Elevated levels of TNF-α and IL-1α have been registered in tear fluid together with an increase in CD3(+) cells in the palpebral conjunctiva when compared to control animals. Additionally, an increase in MMP-9 mRNA expression was recorded in conjunctival tissue. Reference treatment with Restasis(®) and dexamethasone eye drops had a positive effect on all evaluation parameters, except on tear volume. This rat dry eye model was validated extensively and judged appropriate for the evaluation of novel compounds and therapeutic preparations for dry eye disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Eye tracking to evaluate evidence recognition in crime scene investigations.

    PubMed

    Watalingam, Renuka Devi; Richetelli, Nicole; Pelz, Jeff B; Speir, Jacqueline A

    2017-11-01

    Crime scene analysts are the core of criminal investigations; decisions made at the scene greatly affect the speed of analysis and the quality of conclusions, thereby directly impacting the successful resolution of a case. If an examiner fails to recognize the pertinence of an item on scene, the analyst's theory regarding the crime will be limited. Conversely, unselective evidence collection will most likely include irrelevant material, thus increasing a forensic laboratory's backlog and potentially sending the investigation into an unproductive and costly direction. Therefore, it is critical that analysts recognize and properly evaluate forensic evidence that can assess the relative support of differing hypotheses related to event reconstruction. With this in mind, the aim of this study was to determine if quantitative eye tracking data and qualitative reconstruction accuracy could be used to distinguish investigator expertise. In order to assess this, 32 participants were successfully recruited and categorized as experts or trained novices based on their practical experiences and educational backgrounds. Each volunteer then processed a mock crime scene while wearing a mobile eye tracker, wherein visual fixations, durations, search patterns, and reconstruction accuracy were evaluated. The eye tracking data (dwell time and task percentage on areas of interest or AOIs) were compared using Earth Mover's Distance (EMD) and the Needleman-Wunsch (N-W) algorithm, revealing significant group differences for both search duration (EMD), as well as search sequence (N-W). More specifically, experts exhibited greater dissimilarity in search duration, but greater similarity in search sequences than their novice counterparts. In addition to the quantitative visual assessment of examiner variability, each participant's reconstruction skill was assessed using a 22-point binary scoring system, in which significant group differences were detected as a function of total

  7. Evaluating camouflage design using eye movement data.

    PubMed

    Lin, Chiuhsiang Joe; Chang, Chi-Chan; Lee, Yung-Hui

    2014-05-01

    This study investigates the characteristics of eye movements during a camouflaged target search task. Camouflaged targets were randomly presented on two natural landscapes. The performance of each camouflage design was assessed by target detection hit rate, detection time, number of fixations on display, first saccade amplitude to target, number of fixations on target, fixation duration on target, and subjective ratings of search task difficulty. The results showed that the camouflage patterns could significantly affect the eye-movement behavior, especially first saccade amplitude and fixation duration, and the findings could be used to increase the sensitivity of the camouflage assessment. We hypothesized that the assessment could be made with regard to the differences in detectability and discriminability of the camouflage patterns. These could explain less efficient search behavior in eye movements. Overall, data obtained from eye movements can be used to significantly enhance the interpretation of the effects of different camouflage design. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  8. APPLICATION OF EYE TRACKING FOR MEASUREMENT AND EVALUATION IN HUMAN FACTORS STUDIES IN CONTROL ROOM MODERNIZATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kovesdi, C.; Spielman, Z.; LeBlanc, K.

    An important element of human factors engineering (HFE) pertains to measurement and evaluation (M&E). The role of HFE-M&E should be integrated throughout the entire control room modernization (CRM) process and be used for human-system performance evaluation and diagnostic purposes with resolving potential human engineering deficiencies (HEDs) and other human machine interface (HMI) design issues. NUREG-0711 describes how HFE in CRM should employ a hierarchical set of measures, particularly during integrated system validation (ISV), including plant performance, personnel task performance, situation awareness, cognitive workload, and anthropometric/ physiological factors. Historically, subjective measures have been primarily used since they are easier to collectmore » and do not require specialized equipment. However, there are pitfalls with relying solely on subjective measures in M&E such that negatively impact reliability, sensitivity, and objectivity. As part of comprehensively capturing a diverse set of measures that strengthen findings and inferences made of the benefits from emerging technologies like advanced displays, this paper discusses the value of using eye tracking as an objective method that can be used in M&E. A brief description of eye tracking technology and relevant eye tracking measures is provided. Additionally, technical considerations and the unique challenges with using eye tracking in full-scaled simulations are addressed. Finally, this paper shares preliminary findings regarding the use of a wearable eye tracking system in a full-scale simulator study. These findings should help guide future full-scale simulator studies using eye tracking as a methodology to evaluate human-system performance.« less

  9. A single-center, pilot study evaluating a novel TriHex peptide- and botanical-containing eye treatment compared to baseline.

    PubMed

    Reivitis, Alex; Karimi, Kian; Griffiths, Chester; Banayan, Ashley

    2018-04-16

    Topical treatments containing tripeptide and hexapeptide (TriHex technology) have been proven to contribute to youthful skin by clearing the extracellular matrix and stimulating collagen and elastin production. Evaluate the efficacy of a novel eye treatment containing TriHex peptides and other synergistic ingredients for the daily treatment of fine lines/crow's feet around the eyes, under eye hollowing, under eye bags, and dark circles. In this study, 10 subjects (9 female and 1 male) aged 30-60 of Fitzpatrick skin type I, II, or III were selected to use an eye treatment containing TriHex peptides and active botanicals (Alastin Restorative Eye Treatment with TriHex Technology™, ALASTIN Skincare, Inc., Carlsbad, CA) twice daily for 12 weeks. Subjects were photographed and evaluated at baseline, week 4, week 8, and week 12 by a board-certified facial plastic surgeon. Using an adjusted Griffiths scale (0 = none, best possible condition and 9 = severe, worst possible condition), subjects were evaluated on severity of fine lines/crow's feet, under eye hollowing, under eye bags, and dark circles at each visit. Subjects completed a "Subject Questionnaire" at week 4, week 8, and week 12 pertaining to the subject's observations and perceived improvement of these measures. Based on the investigator's assessments, overall improvement in periocular skin was noted for all 10 subjects. Over the course of 12 weeks, raw scores significantly decreased indicating reduction of lines/crow's feet (41% improvement), under eye hollowing (29% improvement), under eye bags (48% improvement), and dark circles (39% improvement). Based on the "Subject Questionnaire," all subjects noted overall improvement of the appearance of skin around the eyes. Based on the findings of this study, this eye treatment containing TriHex peptides and active botanicals is an effective stand-alone treatment for the rejuvenation of periocular skin. When used twice daily, this product can reduce the

  10. Performance evaluation for different sensing surface of BICELLs bio-transducers for dry eye biomarkers

    NASA Astrophysics Data System (ADS)

    Laguna, M. F.; Holgado, M.; Santamaría, B.; López, A.; Maigler, M.; Lavín, A.; de Vicente, J.; Soria, J.; Suarez, T.; Bardina, C.; Jara, M.; Sanza, F. J.; Casquel, R.; Otón, A.; Riesgo, T.

    2015-03-01

    Biophotonic Sensing Cells (BICELLs) are demonstrated to be an efficient technology for label-free biosensing and in concrete for evaluating dry eye diseases. The main advantage of BICELLs is its capability to be used by dropping directly a tear into the sensing surface without the need of complex microfluidics systems. Among this advantage, compact Point of Care read-out device is employed with the capability of evaluating different types of BICELLs packaged on Biochip-Kits that can be fabricated by using different sensing surfaces material. In this paper, we evaluate the performance of the combination of three sensing surface materials: (3-Glycidyloxypropyl) trimethoxysilane (GPTMS), SU-8 resist and Nitrocellulose (NC) for two different biomarkers relevant for dry eye diseases: PRDX-5 and ANXA-11.

  11. Preparation and clinical evaluation of succinylated collagen punctal plugs in dry eye syndrome: a pilot study.

    PubMed

    Hadassah, J; Bhuvaneshwari, Namita; Singh, Deepti; Sehgal, P K

    2010-01-01

    This is a pilot study of 10 eyes of 6 patients. This paper describes the preparation and clinical evaluation of succinylated collagen punctal plugs (SCPP) in the treatment of dry eye syndrome (DES). SCPP were prepared from succinylated collagen with the exact dimensions of the punctum (length 1.5-2.5 mm, diameter 0.2-0.5 mm, water content between 50 and 55%). All the patients were clinically evaluated for best corrected visual acuity (BCVA), tear fluid levels (TFL), protein content, tear fluid osmolarity (TFO), fluorescence staining of the cornea and tear break-up time (TBUT) before and after punctal occlusion with SCPP. TFL improved among all the patients after punctal occlusion with SCPP. BCVA showed improvement in case 4 (right eye/left eye), case 5 (left eye) and case 6 (right eye), who had developed dry eyes due to environmental conditions. Protein content increased on day 7 in all the patients and gradually decreased. TFO decreased on days 3 and 5 in all patients after punctal occlusion with SCPP, and showed the same levels on day 14. TFL, PC, TFO and TBUT showed significant improvement in all the patients after punctal occlusion with SCPP. All patients experienced symptomatic relief after punctal occlusion with SCPP. There was no discomfort, foreign body sensation, plug extrusion, corneal aberration, infection, or formation of pyogenic granuloma with SCPP. SCPP stands as a promising alternative to other punctal plugs in the treatment of DES. Copyright 2010 S. Karger AG, Basel.

  12. Evaluation of the impact of light scatter from glistenings in pseudophakic eyes.

    PubMed

    DeHoog, Edward; Doraiswamy, Anand

    2014-01-01

    To study the impact of light scatter from glistenings in pseudophakic eyes using ray tracing in a model eye Department of Research, Advanced Vision Science, Inc., Goleta, California, USA. Mathematical modeling and simulation. A pseudophakic eye model was constructed in Zemax using the Arizona eye model as the basis. The Mie scattering theory was used to describe the intensity and direction of light as it scatters for a spherical particle immersed in a given media (intraocular lens [IOL]). The modeling and evaluation of scatter and modulation transfer function (MTF) were performed for several biomaterials with various size and density of glistenings under scotopic, mesopic, and photopic conditions. As predicted by the Mie theory, the amount of scatter was a function of the relative difference in refractive index between the media and the scatterer, the size of the scatterer, and the volume fraction of the scatterer. The simulation demonstrated that an increase in density of glistenings can lead to a significant drop in the MTF of the IOL and the pseudophakic eye. This effect was more pronounced in IOLs with smaller cavitations, and the observation was consistent for all tested biomaterials. Mathematical modeling demonstrated that glistenings in IOLs will lead to reduction in the MTF of the IOL and the pseudophakic eye. The loss in MTF was more pronounced at high densities and small cavitation sizes across all biomaterials. Inconsistent and poor clinical quantification of glistenings in IOLs may explain some inconsistencies in the literature. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Evaluation of Eye Metrics as a Detector of Fatigue

    DTIC Science & Technology

    2010-03-01

    eyeglass frames . The cameras are angled upward toward the eyes and extract real-time pupil diameter, eye-lid movement, and eye-ball movement. The...because the cameras were mounted on eyeglass -like frames , the system was able to continuously monitor the eye throughout all sessions. Overall, the...of “ fitness for duty” testing and “real-time monitoring” of operator performance has been slow (Institute of Medicine, 2004). Oculometric-based

  14. EyeTribe Tracker Data Accuracy Evaluation and Its Interconnection with Hypothesis Software for Cartographic Purposes.

    PubMed

    Popelka, Stanislav; Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka

    2016-01-01

    The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe.

  15. EyeTribe Tracker Data Accuracy Evaluation and Its Interconnection with Hypothesis Software for Cartographic Purposes

    PubMed Central

    Stachoň, Zdeněk; Šašinka, Čeněk; Doležalová, Jitka

    2016-01-01

    The mixed research design is a progressive methodological discourse that combines the advantages of quantitative and qualitative methods. Its possibilities of application are, however, dependent on the efficiency with which the particular research techniques are used and combined. The aim of the paper is to introduce the possible combination of Hypothesis with EyeTribe tracker. The Hypothesis is intended for quantitative data acquisition and the EyeTribe is intended for qualitative (eye-tracking) data recording. In the first part of the paper, Hypothesis software is described. The Hypothesis platform provides an environment for web-based computerized experiment design and mass data collection. Then, evaluation of the accuracy of data recorded by EyeTribe tracker was performed with the use of concurrent recording together with the SMI RED 250 eye-tracker. Both qualitative and quantitative results showed that data accuracy is sufficient for cartographic research. In the third part of the paper, a system for connecting EyeTribe tracker and Hypothesis software is presented. The interconnection was performed with the help of developed web application HypOgama. The created system uses open-source software OGAMA for recording the eye-movements of participants together with quantitative data from Hypothesis. The final part of the paper describes the integrated research system combining Hypothesis and EyeTribe. PMID:27087805

  16. Evaluation of a rebound tonometer (Tonovet) in clinically normal cat eyes.

    PubMed

    Rusanen, Elina; Florin, Marion; Hässig, Michael; Spiess, Bernhard M

    2010-01-01

    To determine the accuracy of and to establish reference values for a rebound tonometer (Tonovet) in normal feline eyes, to compare it with an applanation tonometer (Tonopen Vet) and to evaluate the effect of topical anesthesia on rebound tonometry. Six enucleated eyes were used to compare both tonometers with direct manometry. Intraocular pressure (IOP) was measured in 100 cats to establish reference values for rebound tonometry. Of these, 22 cats were used to compare rebound tonometry with and without topical anesthesia and 33 cats to compare the rebound and applanation tonometers. All evaluated eyes were free of ocular disease. Both tonometers correlated well with direct manometry. The best agreement with the rebound tonometer was achieved between 25-50 mmHg. The applanation tonometer was accurate at pressures between 0 and 30 mmHg. The mean IOP in clinically normal cats was 20.74 mmHg with the rebound tonometer and 18.4 mmHg with the applanation tonometer. Topical anesthesia did not significantly affect rebound tonometry. As the rebound tonometer correlated well with direct manometry in the clinically important pressure range and was well tolerated by cats, it appears suitable for glaucoma diagnosis. The mean IOP obtained with the rebound tonometer was 2-3 mmHg higher than that measured with the applanation tonometer. This difference is within clinically acceptable limits, but indicates that the same type of tonometer should be used in follow-up examinations in a given cat.

  17. Face value: eye movements and the evaluation of facial crowds in social anxiety.

    PubMed

    Lange, Wolf-Gero; Heuer, Kathrin; Langner, Oliver; Keijsers, Ger P J; Becker, Eni S; Rinck, Mike

    2011-09-01

    Scientific evidence is equivocal on whether Social Anxiety Disorder (SAD) is characterized by a biased negative evaluation of (grouped) facial expressions, even though it is assumed that such a bias plays a crucial role in the maintenance of the disorder. To shed light on the underlying mechanisms of face evaluation in social anxiety, the eye movements of 22 highly socially anxious (SAs) and 21 non-anxious controls (NACs) were recorded while they rated the degree of friendliness of neutral-angry and smiling-angry face combinations. While the Crowd Rating Task data showed no significant differences between SAs and NACs, the resultant eye-movement patterns revealed that SAs, compared to NACs, looked away faster when the face first fixated was angry. Additionally, in SAs the proportion of fixated angry faces was significantly higher than for other expressions. Independent of social anxiety, these fixated angry faces were the best predictor of subsequent affect ratings for either group. Angry faces influence attentional processes such as eye movements in SAs and by doing so reflect biased evaluations. As these processes do not correlate with explicit ratings of faces, however, it remains unclear at what point implicit attentional behaviors lead to anxiety-prone behaviors and the maintenance of SAD. The relevance of these findings is discussed in the light of the current theories. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. A rating scale is a proper method to evaluate changes in quality of life due to dry eye symptoms.

    PubMed

    Xue, Wenwen; Xu, Xian; Zou, Haidong

    2018-02-07

    To determine which utility value assessment method is more suitable to evaluate changes in the quality of life due to dry eye symptoms. Dry eye outpatients with a presenting visual acuity of 20/25 or better in the worse-seeing eye were recruited. Presenting distance visual acuity, tear film break-up time, Schirmer I test and fluorescein were assessed. The severity of dry eye symptoms was assessed using the Ocular Surface Disease Index (OSDI), and utility values were measured using the time trade-off (TTO), standard gamble (SG1 and SG2) and rating scale (RS) methods. Different utility values were compared with each other. The most appropriate utility value method to evaluate quality-of-life changes solely due to dry eye symptoms is determined by calculating the correlation between the OSDI score and different utility values. A total of 104 patients were enrolled. The three sections of OSDI in the order of high to low scores were as follows: "environmental trigger," "eye discomfort" and "visual function." The utility scores measured with TTO, SG1, SG2 and RS were 0.95 ± 0.11, 0.96 ± 0.10, 0.99 ± 0.07 and 0.89 ± 0.10, respectively. The utility scores evaluated by the TTO, SG1, SG2 and RS methods were significantly different from each other (p < 0.05). Only the utility scores measured with RS were significantly correlated with the composite OSDI score, "environmental trigger" and "eye discomfort" section scores (p < 0.05). RS is more sensitive than TTO and SG for the evaluation of altered quality of life due to dry eye symptoms.

  19. Evaluation of a Web-Based Training in Smoking Cessation Counseling Targeting U.S. Eye-Care Professionals

    ERIC Educational Resources Information Center

    Asfar, Taghrid; Lee, David J.; Lam, Byron L.; Murchison, Ann P.; Mayro, Eileen L.; Owsley, Cynthia; McGwin, Gerald; Gower, Emily W.; Friedman, David S.; Saaddine, Jinan

    2018-01-01

    Background: Smoking causes blindness-related diseases. Eye-care providers are uniquely positioned to help their patients quit smoking. Aims: Using a pre-/postevaluation design, this study evaluated a web-based training in smoking cessation counseling targeting eye-care providers. Method: The training was developed based on the 3A1R protocol:…

  20. Unilateral Amblyopia Affects Two Eyes: Fellow Eye Deficits in Amblyopia.

    PubMed

    Meier, Kimberly; Giaschi, Deborah

    2017-03-01

    Unilateral amblyopia is a visual disorder that arises after selective disruption of visual input to one eye during critical periods of development. In the clinic, amblyopia is understood as poor visual acuity in an eye that was deprived of pattern vision early in life. By its nature, however, amblyopia has an adverse effect on the development of a binocular visual system and the interactions between signals from two eyes. Visual functions aside from visual acuity are impacted, and many studies have indicated compromised sensitivity in the fellow eye even though it demonstrates normal visual acuity. While these fellow eye deficits have been noted, no overarching theory has been proposed to describe why and under what conditions the fellow eye is impacted by amblyopia. Here, we consider four explanations that may account for decreased fellow eye sensitivity: the fellow eye is adversely impacted by treatment for amblyopia; the maturation of the fellow eye is delayed by amblyopia; fellow eye sensitivity is impacted for visual functions that rely on binocular cortex; and fellow eye deficits reflect an adaptive mechanism that works to equalize the sensitivity of the two eyes. To evaluate these ideas, we describe five visual functions that are commonly reported to be deficient in the amblyopic eye (hyperacuity, contrast sensitivity, spatial integration, global motion, and motion-defined form), and unify the current evidence for fellow eye deficits. Further research targeted at exploring fellow eye deficits in amblyopia will provide us with a broader understanding of normal visual development and how amblyopia impacts the developing visual system.

  1. Effect of Autologous Serum Eye Drops in Patients with Sjögren Syndrome-related Dry Eye: Clinical and In Vivo Confocal Microscopy Evaluation of the Ocular Surface.

    PubMed

    Semeraro, Francesco; Forbice, Eliana; Nascimbeni, Giuseppe; Taglietti, Marco; Romano, Vito; Guerra, Germano; Costagliola, Ciro

    To evaluate in vivo changes after therapy using autologous serum (AS) eye drops in Sjögren's syndrome (SS)-related dry eyes by confocal microscopy. In this study, 24 patients with SS-related dry eyes [12 in AS eye drop therapy and 12 in artificial tear (AT) therapy] and 24 healthy volunteers were recruited. Ocular Surface Disease Index (OSDI), central corneal thickness, tear film, break-up time, corneal and conjunctival staining, Schirmer's test and corneal confocal microscopy were investigated. Tear production, tear stability, corneal staining, inflammation, and central corneal thickness, Langherans cells, activated keratocytes, intermediate epithelial cell density, nerve tortuosity, number of sub-basal nerve branches, and number of bead-like formations differed between patients and controls (p<0.0001). The AT and AS groups differed in the OSDI, number of branches, and number of beadings (p<0.0001). AS eye drops improve symptoms and confocal microscopy findings in SS-related dry eyes. Copyright © 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  2. Eye wash water flow direction study: an evaluation of the effectiveness of eye wash devices with opposite directional water flow.

    PubMed

    Fogt, Jennifer S; Jones-Jordan, Lisa A; Barr, Joseph T

    2018-01-01

    New designs of eye wash stations have been developed in which the direction of water flow from the fountain has been reversed, with two water streams originating nasally in both eyes and flowing toward the temporal side of each eye. No study has been done to determine the ideal direction of water flow coming from the eye wash in relation to the eye. Ophthalmic eye examinations were conducted before and after the use of two eye wash stations with opposite water flow directionality. Fluorescein was instilled in both eyes before using an eye wash to measure the effectiveness of the water flow. Subjects were surveyed upon their experiences using the eye washes. Ophthalmic examination found no significant difference in the efficacy of the eye washes with nasal-to-temporal water flow when compared to temporal-to-nasal water flow direction.

  3. Healthy Eyes in Schools: An Evaluation of a School and Community-Based Intervention to Promote Eye Health in Rural Timor-Leste

    ERIC Educational Resources Information Center

    Hobday, Karen; Ramke, Jacqueline; du Toit, Rènée; Pereira, Sara M.

    2015-01-01

    Objective: To assess whether there was an improvement in the knowledge, attitudes and practices of students after the Healthy Eyes in Schools Project intervention and to complete a process evaluation to inform future implementation of health promotion interventions. Design: A descriptive, mixed-methods design was used, including questionnaires and…

  4. CON4EI: Evaluation of QSAR models for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Geerts, L; Adriaens, E; Alépée, N; Guest, R; Willoughby, J A; Kandarova, H; Drzewiecka, A; Fochtman, P; Verstraelen, S; Van Rompay, A R

    2018-06-01

    Assessment of ocular irritation is a regulatory requirement in safety evaluation of industrial and consumer products. Although a number of in vitro ocular irritation assays exist, none are capable of fully categorizing chemicals as stand-alone assays. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI (CONsortium for in vitro Eye Irritation testing strategy) project was developed to assess the reliability of eight in vitro test methods and computational models as well as establishing an optimal tiered-testing strategy. For three computational models (Toxtree, and Case Ultra EYE_DRAIZE and EYE_IRR) performance parameters were calculated. Coverage ranged from 15 to 58%. Coverage was 2 to 3.4 times higher for liquids than for solids. The lowest number of false positives (5%) was reached with EYE_IRR; this model however also gave a high number of false negatives (46%). The lowest number of false negatives (25%) was seen with Toxtree; for liquids Toxtree predicted the lowest number of false negatives (11%), for solids EYE_DRAIZE did (17%). It can be concluded that the training sets should be enlarged with high quality data. The tested models are not yet sufficiently powerful for stand-alone evaluations, but that they can surely become of value in an integrated weight-of-evidence approach in hazard assessment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Evaluation of eye injury risk from projectile shooting toys using the focus headform - biomed 2009.

    PubMed

    Bisplinghoff, Jill A; Duma, Stefan M

    2009-01-01

    Half of eye injuries in the United States are caused by a blunt impact and more specifically, eye injuries effecting children often result from projectile shooting toys. The purpose of this study is to evaluate the risk of eye injuries of currently available projectile shooting toys. In order to assess the risk of each toy, a Facial and Ocular Countermeasure Safety (FOCUS) headform was used to measure the force applied to the eye during each hit for a total of 18 tests. The selected toys included a dart gun, a foam launcher, and a ball launcher. The force ranged from 4-93 N and was analyzed using the injury risk function for globe rupture for the FOCUS headform. Projectile characteristics were also examined using normalized energy to determine risk of corneal abrasion, hyphema, lens dislocation, retinal damage and globe rupture. It was found that the three toys tested produced peak loads corresponding with risk of globe rupture between 0% and 17.3%. The normalized energy results show no risk of hyphema, lens dislocation, retinal damage or globe rupture and a maximum risk of corneal abrasion of 5.9%. This study concludes that although there are many eye injuries caused by projectiles, the selected toys show a very low risk of eye injury.

  6. [Evaluation of eye patching after cataract surgery in topical anesthesia].

    PubMed

    Mayer, S; Wirbelauer, C; Häberle, H; Altmeyer, M; Pham, D T

    2005-01-01

    Although postoperative eye patching is a common practice its background is not well known. Therefore the necessity of eye patching after cataract surgery in topical anesthesia from the medical point of view and the patients' subjective opinion was studied. In this prospective and randomized study 133 patients received after cataract surgery either no covering of the eye (group1), a transparent eye shield for four hours (group 2), an eye pad for four hours (group 3) or an eye pad until the next morning (group 4). Clinical findings were noted and local symptoms, such as pain, foreign body sensation, tearing and photophobia were documented on a visual analogue scale (0 - 10). Furthermore, a questionnaire concerning the subjective opinion was handed out to the patient. The clinical findings revealed no significant differences between the groups. The mean values for local pain were 0.94 +/- 1.56, for the foreign body sensation 1.41 +/- 2.02, for tearing 0.99 +/- 1.8 and for photophobia 1.05 +/- 1.99. Comparing the groups there was significantly more pain and foreign body sensation reported by the patients in group 3, who received eye patching for 4 hours. 91 % of the unpatched patients had no discomfort, whereas 53 % of the patients wearing an eye pad until the next morning considered it as unnecessary. After cataract surgery in topical anesthesia only mild symptoms were noted. There were no significant differences between the groups in the objective clinical findings and the subjective feeling. These results indicate that after cataract surgery eye patching could be unnecessary.

  7. One algorithm to rule them all? An evaluation and discussion of ten eye movement event-detection algorithms.

    PubMed

    Andersson, Richard; Larsson, Linnea; Holmqvist, Kenneth; Stridh, Martin; Nyström, Marcus

    2017-04-01

    Almost all eye-movement researchers use algorithms to parse raw data and detect distinct types of eye movement events, such as fixations, saccades, and pursuit, and then base their results on these. Surprisingly, these algorithms are rarely evaluated. We evaluated the classifications of ten eye-movement event detection algorithms, on data from an SMI HiSpeed 1250 system, and compared them to manual ratings of two human experts. The evaluation focused on fixations, saccades, and post-saccadic oscillations. The evaluation used both event duration parameters, and sample-by-sample comparisons to rank the algorithms. The resulting event durations varied substantially as a function of what algorithm was used. This evaluation differed from previous evaluations by considering a relatively large set of algorithms, multiple events, and data from both static and dynamic stimuli. The main conclusion is that current detectors of only fixations and saccades work reasonably well for static stimuli, but barely better than chance for dynamic stimuli. Differing results across evaluation methods make it difficult to select one winner for fixation detection. For saccade detection, however, the algorithm by Larsson, Nyström and Stridh (IEEE Transaction on Biomedical Engineering, 60(9):2484-2493,2013) outperforms all algorithms in data from both static and dynamic stimuli. The data also show how improperly selected algorithms applied to dynamic data misestimate fixation and saccade properties.

  8. Evaluation of RGD peptide hydrogel in the posterior segment of the rabbit eye.

    PubMed

    Wang, Xing-Hua; Li, Shuang; Liang, Liang; Xu, Xiao-Ding; Zhang, Xian-Zheng; Jiang, Fa-Gang

    2013-01-01

    The aim of this study was to evaluate the biocompatibility and biodegradability of RGD peptide hydrogel in the posterior segment of the eye as a biomaterial potentially useful for sustained drug delivery systems. RGD peptide hydrogel was injected into the vitreous cavity and suprachoroidal space of rabbit eyes. Clinical follow-up and histological observation were performed up to four weeks. The biodegradability was also evaluated by the lifetime of the hydrogel which was defined by ophthalmoscopic observation or ultrasonography. The results showed that RGD peptide hydrogel was well tolerated in the vitreous cavity and suprachoroidal space, and disappeared from the injection sites progressively. As for suprachoroidal injection, the hydrogel was clearly identified by ultrasound echography and was confirmed innoxious to the retinal vessels by fluorescein angiography. Histological observations showed that the structures of retina, choroid and other tissues around the injection site remained normal after the injection. The lifetime of the hydrogel was 25.7 ± 2.65 days and 14.3 ± 3.3 days in the vitreous cavity and suprachoroidal space, respectively. The results obtained demonstrated that RGD peptide hydrogel, which showed excellent biocompatibility and favorable biodegradability in the posterior segment of rabbit eyes, appears to be a promising biomaterial to deliver drugs focally to the choroid and the retina.

  9. EVALUATION OF EYE LENS DOSES OF INTERVENTIONAL CARDIOLOGISTS.

    PubMed

    Yokoyama, Sumi; Suzuki, Shoichi; Toyama, Hiroshi; Arakawa, Shinji; Inoue, Satoshi; Kinomura, Yutaka; Kobayashi, Ikuo

    2017-04-01

    The effective dose of medical staff members, especially interventional radiologists and cardiologists, is classified as a relatively high level. We measured the dose for interventional cardiologists by using optically stimulated luminescence dosimeters (OSLDs). However, this quantity is not the same as Hp (3). In experiments, the dose at the eye-lens position of a phantom were measured using OSLDs and thermoluminescence dosimeters (TLDs). A conversion factor from dose measured by using TLDs to OSLDs was estimated from these results. In addition, the eye doses of interventional cardiologists in clinical situations were measured, and the effect of eyewear on the eye-lens dose was discussed. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Development of criteria for evaluating clinical response in thyroid eye disease using a modified Delphi technique.

    PubMed

    Douglas, Raymond S; Tsirbas, Angelo; Gordon, Mark; Lee, Diana; Khadavi, Nicole; Garneau, Helene Chokron; Goldberg, Robert A; Cahill, Kenneth; Dolman, Peter J; Elner, Victor; Feldon, Steve; Lucarelli, Mark; Uddin, Jimmy; Kazim, Michael; Smith, Terry J; Khanna, Dinesh

    2009-09-01

    To identify components of a provisional clinical response index for thyroid eye disease using a modified Delphi technique. The International Thyroid Eye Disease Society conducted a structured, 3-round Delphi exercise establishing consensus for a core set of measures for clinical trials in thyroid eye disease. The steering committee discussed the results in a face-to-face meeting (nominal group technique) and evaluated each criterion with respect to its feasibility, reliability, redundancy, and validity. Redundant measures were consolidated or excluded. Criteria were parsed into 11 domains for the Delphi surveys. Eighty-four respondents participated in the Delphi 1 survey, providing 220 unique items. Ninety-two members (100% of the respondents from Delphi 1 plus 8 new participants) responded in Delphi 2 and rated the same 220 items. Sixty-four members (76% of participants) rated 153 criteria in Delphi 3 (67 criteria were excluded because of redundancy). Criteria with a mean greater than 6 (1 = least appropriate to 9 = most appropriate) were further evaluated by the nominal group technique and provisional core measures were chosen. Using a Delphi exercise, we developed provisional core measures for assessing disease activity and severity in clinical trials of therapies for thyroid eye disease. These measures will be iteratively refined for use in multicenter clinical trials.

  11. Accuracy of a technology-assisted eye exam in evaluation of referable diabetic retinopathy and concomitant ocular diseases.

    PubMed

    Conlin, Paul R; Asefzadeh, Baharak; Pasquale, Louis R; Selvin, Gerald; Lamkin, Rebecca; Cavallerano, Anthony A

    2015-12-01

    Digital retinal imaging using store-and-forward technology is used to screen for diabetic retinopathy (DR). Its usefulness in detecting non-diabetic eye diseases is uncertain. We determined the level of agreement between teleretinal imaging supplemented with visual acuity and intraocular pressure (IOP) measurements (ie, technology-assisted eye (TAE) exam) and a comprehensive eye exam in evaluation for DR and non-diabetic ocular conditions. We conducted a prospective, observational study with two parallel evaluations. Patients with diabetes (n=317) had a TAE exam and a comprehensive eye exam on the same day. A subset of participants with normal baseline exams (n=72) had follow-up exams 1 year later. We measured the level of agreement for referable ocular findings. Agreement for referable ocular findings was moderate (n=389, agreement: 77%; κ: 0.55), due in part to ungradable exams (22%). However, about half of the ungradable exams had findings that warranted referral. There was substantial agreement for follow-up exams (n=72, agreement: 93%; κ: 0.63). Among all gradable exams (n=303), the TAE exam had 86% sensitivity and 84% specificity for referable ocular findings, with high agreement (≥94%) for DR and other major ocular diagnoses. There was moderate-to-substantial agreement between a TAE exam and a comprehensive eye exam for referable ocular findings in patients with diabetes. Ungradable exams were a frequent marker of ocular pathology. Teleretinal imaging may be a useful evaluation for both diabetic and non-diabetic ocular conditions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. FogEye UV Sensor System Evaluation : Phase I Report.

    DOT National Transportation Integrated Search

    2002-09-01

    FogEye technology uses the solar-blind reigion of the ultraviolet spectrum to develop sensors or systems that are unaffected by sunlight. The U.S. Congress asked the Federal Aviation Administration to investigate the feasibility of applying FogEye te...

  13. Implementation evaluation of a culturally competent eye injury prevention program for citrus workers in a Florida migrant community.

    PubMed

    Luque, John S; Monaghan, Paul; Contreras, Ricardo B; August, Euna; Baldwin, Julie A; Bryant, Carol A; McDermott, Robert J

    2007-01-01

    The Partnership for Citrus Worker Health (PCWH) is a coalition that connects academic institutions, public health agencies, industry and community-based organizations for implementation of an eye safety pilot project with citrus workers using the Camp Health Aide (CHA) model. This project was an implementation evaluation of an eye safety curriculum using modeling and peer-to-peer education among Mexican migrant citrus workers in a southwest Florida community to increase positive perceptions toward the use of safety eyewear and reduce occupational eye injuries. CHAs have been employed and trained in eye safety and health during harvesting seasons since 2004. Field observations, focus group interviews, and written questionnaires assessed program implementation and initial outcomes. There was an increase in positive perceptions toward use of safety eyewear between 2004 and 2005. Evaluation of training suggested ways to improve the curriculum. The modest literacy level of the CHAs necessitated some redesign of the curriculum and its implementation (e.g., introduction of and more reliance on use of training posters). PCWH benefited by extensive documentation of the training and supervision, a pilot project that demonstrated the potential effectiveness of CHAs, and having a well-defined target population of citrus workers (n = 427). Future research can rigorously test the effectiveness of CHAs in reducing eye injuries among citrus workers.

  14. Evaluating the risk of eye injuries: intraocular pressure during high speed projectile impacts.

    PubMed

    Duma, Stefan M; Bisplinghoff, Jill A; Senge, Danielle M; McNally, Craig; Alphonse, Vanessa D

    2012-01-01

    To evaluate the risk of eye injuries by determining intraocular pressure during high speed projectile impacts. A pneumatic cannon was used to impact eyes with a variety of projectiles at multiple velocities. Intraocular pressure was measured with a small pressure sensor inserted through the optic nerve. A total of 36 tests were performed on 12 porcine eyes with a range of velocities between 6.2 m/s and 66.5 m/s. Projectiles selected for the test series included a 6.35  mm diameter metal ball, a 9.25  mm diameter aluminum rod, and an 11.16  mm diameter aluminum rod. Experiments were designed with velocities in the range of projectile consumer products such as toy guns. A range of intraocular pressures ranged between 2017 mmHg to 26,426 mmHg (39 psi-511 psi). Four of the 36 impacts resulted in globe rupture. Intraocular pressures dramatically above normal physiological pressure were observed for high speed projectile impacts. These pressure data provide critical insight to chronic ocular injuries and long-term complications such as glaucoma and cataracts.

  15. Evaluation of the toxicity of graphene oxide exposure to the eye.

    PubMed

    Wu, Wei; Yan, Liang; Wu, Qian; Li, Yijian; Li, Qiyou; Chen, Siyu; Yang, Yuli; Gu, Zhanjun; Xu, Haiwei; Yin, Zheng Qin

    2016-11-01

    Graphene and its derivatives are the new carbon nanomaterials with the prospect for great applications in electronics, energy storage, biosensors and medicine. However, little is known about the toxicity of graphene or its derivatives in the case of occasional or repeated ocular exposure. We performed in vitro and in vivo studies to evaluate the toxicity of graphene oxide (GO) exposure to the eye. Primary human corneal epithelium cells (hCorECs) and human conjunctiva epithelium cells (hConECs) were exposed to GO (12.5-100 μg/mL). Acute GO exposure (2 h) did not induce cytotoxicity to hCorECs. However, short-term GO exposure (24 h) exerted significant cytotoxicity to hCorECs and hConECs with increased intracellular reactive oxygen species (ROS). Glutathione (GSH) reduced the GO-induced cytotoxicity. We further performed acute eye irritation tests in albino rabbits according to the Organization for Economic Cooperation and Development (OECD) guidelines, and the rabbits did not exhibit corneal opacity, conjunctival redness, abnormality of the iris, or chemosis at any time point after the instillation of 100 μg/mL of GO. However, 5-day repeated GO exposure (50 and 100 μg/mL) caused reversible mild corneal opacity, conjunctival redness and corneal epithelium damage to Sprague-Dawley rats, which was also alleviated by GSH. Therefore, our study suggests that GO-induced time- and dose-dependent cytotoxicity to hCorECs and hConECs via oxidative stress. Occasional GO exposure did not cause acute eye irritation; short-term repeated GO exposure generally resulted in reversible damage to the eye via oxidative stress, which may be alleviated by the antioxidant GSH.

  16. In vitro eye corrosion study of agrochemicals on isolated chicken eye.

    PubMed

    Buda, I; Budai, P; Szabó, R; Lehel, J

    2013-01-01

    Agrochemicals must undergo numberless toxicological tests before marketing. The eye irritation test is part of this test packet. Nowadays, OECD 405 can be used to classify the irritation potential of substances, the base of the OECD 405 guideline is the Draize test, which is one of the most criticized in vivo methods because of the injuries of the test animals and subjective nature of the test in recording the results. Therefore, several in vitro tests have been developed to replace totally or partly the in vivo eye irritation testing. The isolated chicken eye test method (OECD 438), which was used, is one of these alternative methods. Five different agrochemicals were examined in the following way: All test compounds were applied in a single dose onto the cornea of isolated chicken eyes in order to potentially classify the test compounds as ocular corrosive and/or severe irritant. The damages caused by the test substances were assessed by the determination of corneal swelling, opacity, fluorescein retention and morphological effects. These parameters were evaluated pre-treatment and starting at approximately 30, 75, 120, 180, and 240 minutes after the post-treatment rinse. The endpoints evaluated were corneal opacity, swelling, fluorescein retention and morphological effects. All of the endpoints, with the exception of fluorescein retention (which was determined only at pre-treatment and 30 minutes after test substance exposure) were determined at each of the above time points. Positive and negative controls were used and they showed the expected results in each study. In these in vitro eye corrosives and severe irritants studies, using the Isolated Chicken Eye model with five different products, no ocular corrosion or severe irritation potential were observed. These results correspond to the available information about the tested agrochemicals, so these studies with isolated chicken eye are considered to be successful.

  17. Ethnomedical survey and safety evaluation of traditional eye medicines used in Misungwi district, Tanzania

    PubMed Central

    Maregesi, Sheila M.; Messo, Charles W.; Mathias, Juma

    2017-01-01

    Aim: This study aimed at documenting products used as traditional eye medicine (TEM) in Misungwi district, Tanzania, and performing preliminary analysis on safety status. Methodology: Ethnomedical study was conducted in Misungwi district. Information was sourced by face-to-face interview with traditional healers, traditional medicine vendors, and knowledgeable people guided by a well-structured questionnaire. Safety was evaluated by determining pH using pH meter and mineral analysis using the Delta, Portable X-ray fluorescence equipment, and qualitative chemical tests. Results: A total of 23 TEM products were recorded from botanical (79%) and zoological (21%) sources including animal excreta. Liquid preparation ranked highest among dosage forms. Safety evaluation showed that only one product possessed the pH value of 7.4 as recommended for topical ophthalmic medicines. Fourteen minerals were detected and quantified in three samples; some of these minerals are known for their negative effects to the eyes, of medical interest is strontium used for the management of benign eye tumors. Information providers were unaware of health risks associated with the use of TEM. Conclusion: This study has revealed the common use of TEM in Misungwi district. The majority of the products are from the botanical source. Although literature provides supporting data for the application to some of the recorded TEM, safety evaluation by pH and mineral analysis in this study have indicated possible ophthalmological medical problems that could result from using such products. Extensive scientific studies including animal experiments and identification of bioactive compounds are essential to develop safe TEMs. PMID:28163964

  18. Impact of dry eye on work productivity.

    PubMed

    Yamada, Masakazu; Mizuno, Yoshinobu; Shigeyasu, Chika

    2012-01-01

    The purpose of this study was to evaluate the impact of dry eye on work productivity of office workers, especially in terms of presenteeism. A total of 396 individuals aged ≥20 years (258 men and 138 women, mean age 43.4 ± 13.0 years) were recruited through an online survey. Data from 355 responders who did not have missing values were included in the analysis. They were classified into the following four groups according to the diagnostic status and subjective symptoms of dry eye: a definite dry eye group; a marginal dry eye group; a self-reported dry eye group; and a control group. The impact of dry eye on work productivity was evaluated using the Japanese version of the Work Limitations Questionnaire. The cost of work productivity loss associated with dry eye and the economic benefits of providing treatment for dry eye were also assessed. The degree of work performance loss was 5.65% in the definite dry eye group, 4.37% in the marginal dry eye group, 6.06% in the self-reported dry eye group, and 4.27% in the control group. Productivity in the self-reported dry eye group was significantly lower than that in the control group (P < 0.05). The annual cost of work productivity loss associated with dry eye was estimated to be USD 741 per person. Dry eye impairs work performance among office workers, which may lead to a substantial loss to industry. Management of symptoms of dry eye by providing treatment may contribute to improvement in work productivity.

  19. The cost-effectiveness of Welcome to Medicare visual acuity screening and a possible alternative welcome to medicare eye evaluation among persons without diagnosed diabetes mellitus.

    PubMed

    Rein, David B; Wittenborn, John S; Zhang, Xinzhi; Hoerger, Thomas J; Zhang, Ping; Klein, Barbara Eden Kobrin; Lee, Kris E; Klein, Ronald; Saaddine, Jinan B

    2012-05-01

    To estimate the cost-effectiveness of visual acuity screening performed in primary care settings and of dilated eye evaluations performed by an eye care professional among new Medicare enrollees with no diagnosed eye disorders. Medicare currently reimburses visual acuity screening for new enrollees during their initial preventive primary care health check, but dilated eye evaluations may be a more cost-effective policy. Monte Carlo cost-effectiveness simulation model with a total of 50 000 simulated patients with demographic characteristics matched to persons 65 years of age in the US population. Compared with no screening policy, dilated eye evaluations increased quality-adjusted life-years(QALYs) by 0.008 (95% credible interval [CrI], 0.005-0.011) and increased costs by $94 (95% CrI, −$35 to$222). A visual acuity screening increased QALYs in less than 95% of the simulations (0.001 [95% CrI, −0.002 to 0.004) and increased total costs by $32 (95% CrI, −$97 to $159) per person. The incremental cost-effectiveness ratio of a visual acuity screening and an eye examination compared with no screening were $29 000 and$12 000 per QALY gained, respectively. At a willingness-to-pay value of $15 000 or more per QALY gained, a dilated eye evaluation was the policy option most likely to be cost-effective. The currently recommended visual acuity screening showed limited efficacy and cost-effectiveness compared with no screening. In contrast, anew policy of reimbursement for Welcome to Medicare dilated eye evaluations was highly cost-effective.

  20. MAPK Target Sites of Eyes Absent Are Not Required for Eye Development or Survival in Drosophila

    PubMed Central

    Jusiak, Barbara; Abulimiti, Abuduaini; Haelterman, Nele; Chen, Rui; Mardon, Graeme

    2012-01-01

    Eyes absent (Eya) is a highly conserved transcription cofactor and protein phosphatase that plays an essential role in eye development and survival in Drosophila. Ectopic eye induction assays using cDNA transgenes have suggested that mitogen activated protein kinase (MAPK) activates Eya by phosphorylating it on two consensus target sites, S402 and S407, and that this activation potentiates the ability of Eya to drive eye formation. However, this mechanism has never been tested in normal eye development. In the current study, we generated a series of genomic rescue transgenes to investigate how loss- and gain-of-function mutations at these two MAPK target sites within Eya affect Drosophila survival and normal eye formation: eya+GR, the wild-type control; eyaSAGR, which lacks phosphorylation at the two target residues; and eyaSDEGR, which contains phosphomimetic amino acids at the same two residues. Contrary to the previous studies in ectopic eye development, all eya genomic transgenes tested rescue both eye formation and survival equally effectively. We conclude that, in contrast to ectopic eye formation, MAPK-mediated phosphorylation of Eya on S402 and S407 does not play a role in normal development. This is the first study in Drosophila to evaluate the difference in outcomes between genomic rescue and ectopic cDNA-based overexpression of the same gene. These findings indicate similar genomic rescue strategies may prove useful for re-evaluating other long-standing Drosophila developmental models. PMID:23251383

  1. Evaluating the efficacy of fully automated approaches for the selection of eye blink ICA components

    PubMed Central

    Pontifex, Matthew B.; Miskovic, Vladimir; Laszlo, Sarah

    2017-01-01

    Independent component analysis (ICA) offers a powerful approach for the isolation and removal of eye blink artifacts from EEG signals. Manual identification of the eye blink ICA component by inspection of scalp map projections, however, is prone to error, particularly when non-artifactual components exhibit topographic distributions similar to the blink. The aim of the present investigation was to determine the extent to which automated approaches for selecting eye blink related ICA components could be utilized to replace manual selection. We evaluated popular blink selection methods relying on spatial features [EyeCatch()], combined stereotypical spatial and temporal features [ADJUST()], and a novel method relying on time-series features alone [icablinkmetrics()] using both simulated and real EEG data. The results of this investigation suggest that all three methods of automatic component selection are able to accurately identify eye blink related ICA components at or above the level of trained human observers. However, icablinkmetrics(), in particular, appears to provide an effective means of automating ICA artifact rejection while at the same time eliminating human errors inevitable during manual component selection and false positive component identifications common in other automated approaches. Based upon these findings, best practices for 1) identifying artifactual components via automated means and 2) reducing the accidental removal of signal-related ICA components are discussed. PMID:28191627

  2. Using optical coherence tomography to evaluate glaucoma implant healing response in rabbit eyes

    NASA Astrophysics Data System (ADS)

    Gossage, Kirk W.; Tkaczyk, Tomasz S.; Barton, Jennifer K.

    2002-06-01

    Glaucoma is a set of diseases that cause optic nerve damage and visual field loss. The most important risk factor for the development of glaucoma is elevated intraocular pressure. One approach used to alleviate the pressure increase is to surgically install glaucoma implants. Two standard Ahmed and ten experimental ePTFE implants were evaluated in this study in rabbit eyes. The implants were imaged with optical coherence tomography (OCT) at 0, 7, 15, 30, and 90 days after implantation. Histology was collected at days 7, 15, 30, and 90 and compared to the OCT images. Preliminary analysis of images indicates that OCT can visualize the development of fibrous encapsulation of the implant, tissue erosion, fibrin accumulation in the implant tube, and tube position in the anterior chamber. A new OCT handheld probe was developed to facilitate in vivo imaging in rabbit eye studies. The OCT probe consists of a mechanical scaffold designed to allow the imaging fiber to be held in a fixed position with respect to the rabbit eye, with minimal anesthesia. A piezo electric lateral scanning device allows the imaging fiber to be scanned across the tissue so that 2D images may be acquired.

  3. Fetal Eye Movements on Magnetic Resonance Imaging

    PubMed Central

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C.; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Objectives Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Methods Dynamic SSFP sequences were acquired in 72 singleton fetuses (17–40 GW, three age groups [17–23 GW, 24–32 GW, 33–40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. Results In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3–45%. Conclusions In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations. PMID:24194885

  4. Fetal eye movements on magnetic resonance imaging.

    PubMed

    Woitek, Ramona; Kasprian, Gregor; Lindner, Christian; Stuhr, Fritz; Weber, Michael; Schöpf, Veronika; Brugger, Peter C; Asenbaum, Ulrika; Furtner, Julia; Bettelheim, Dieter; Seidl, Rainer; Prayer, Daniela

    2013-01-01

    Eye movements are the physical expression of upper fetal brainstem function. Our aim was to identify and differentiate specific types of fetal eye movement patterns using dynamic MRI sequences. Their occurrence as well as the presence of conjugated eyeball motion and consistently parallel eyeball position was systematically analyzed. Dynamic SSFP sequences were acquired in 72 singleton fetuses (17-40 GW, three age groups [17-23 GW, 24-32 GW, 33-40 GW]). Fetal eye movements were evaluated according to a modified classification originally published by Birnholz (1981): Type 0: no eye movements; Type I: single transient deviations; Type Ia: fast deviation, slower reposition; Type Ib: fast deviation, fast reposition; Type II: single prolonged eye movements; Type III: complex sequences; and Type IV: nystagmoid. In 95.8% of fetuses, the evaluation of eye movements was possible using MRI, with a mean acquisition time of 70 seconds. Due to head motion, 4.2% of the fetuses and 20.1% of all dynamic SSFP sequences were excluded. Eye movements were observed in 45 fetuses (65.2%). Significant differences between the age groups were found for Type I (p = 0.03), Type Ia (p = 0.031), and Type IV eye movements (p = 0.033). Consistently parallel bulbs were found in 27.3-45%. In human fetuses, different eye movement patterns can be identified and described by MRI in utero. In addition to the originally classified eye movement patterns, a novel subtype has been observed, which apparently characterizes an important step in fetal brainstem development. We evaluated, for the first time, eyeball position in fetuses. Ultimately, the assessment of fetal eye movements by MRI yields the potential to identify early signs of brainstem dysfunction, as encountered in brain malformations such as Chiari II or molar tooth malformations.

  5. Evaluation of point-of-care test for elevated tear matrix metalloproteinase 9 in post-LASIK dry eyes.

    PubMed

    Chan, Tommy C Y; Ye, Cong; Chan, Kwok Ping; Chu, Kai On; Jhanji, Vishal

    2016-09-01

    To evaluate the performance of a point-of-care test for detection of matrix metalloproteinase 9 (MMP-9) levels in post-laser-assisted in situ keratomileusis (LASIK) dry eyes. A comparative study between patients with mild to moderate post-LASIK dry eyes and age-matched normal subjects was conducted. Ocular surface disease index (OSDI), tear break-up time (TBUT), and tear film MMP-9 and total protein levels were compared between the two groups. A point-of-care test device (RPS InflammaDry, Sarasota, Florida, USA) was utilised to confirm elevated MMP-9 levels in tear film. Fourteen post-LASIK dry eyes and 34 normal eyes were included. There was no significant difference in age and gender between both groups (p>0.175). The OSDI was significantly higher (25.5±7.7 vs 7.4±2.5; p<0.001) and TBUT levels were significantly lower (5.4±0.9 vs 13.5±2.3; p<0.001) in patients with dry eye compared with normal subjects. The tear film MMP-9 levels were 52.7±32.5 ng/mL in dry eyes and 4.1±2.1 ng/mL in normal eyes (p<0.001). MMP-9 levels were >40 ng/mL in 7/14 (50.0%) post-LASIK dry eyes. The InflammaDry was positive in 8/14 (57.1%) post-LASIK eyes. All positive cases had tear film MMP-9 levels ≥38.03 ng/mL. Agreement between InflammaDry and MMP-9 was excellent with Cohen κ value of 0.857 in post-LASIK dry eyes. Only half of post-LASIK dry eyes were found to have significant inflammation associated with elevated MMP-9. The OSDI is useful to non-specifically identify patients with symptomatic dry eye while the InflammaDry determined which patients with dry eye were associated with significant inflammation that may guide therapeutic management decisions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  6. The Evaluation of Anatomic and Functional Changes in Unilateral Moderate Amblyopic Eyes Using Optical Coherence Tomography and Pupil Cycle Time.

    PubMed

    Kusbeci, Tuncay; Karti, Omer; Karahan, Eyyup; Oguztoreli, Mustafa

    2017-12-01

    To investigate whether macular anatomic structure and afferent visual system function differ among amblyopic eyes, non-amblyopic fellow eyes, and controls, using spectral-domain optical coherence tomography (SD-OCT), and pupil cycle time (PCT). This observational, cross-sectional study included 30 patients with unilateral amblyopia and 30 healthy subjects. Optical coherence tomography (OCT) and pupil cycle time (PCT) were used to evaluate patients with unilateral amblyopia and were compared with their non-amblyopic fellow eyes and age- and gender-matched healthy eyes (30 participants). The amblyopic eyes were separated into two groups: anisometropic amblyopia (n = 16) and strabismic amblyopia (n = 14). OCT maps were used to calculate central macular thickness (CMT), retinal nerve fiber layer thickness (RNFLT), and ganglion cell-inner plexiform layer (GC-IPL) thickness. The average RNFLT, GC-IPL thickness, and CMT did not show any significant differences among the amblyopic eyes, non-amblyopic fellow eyes and controls (p > 0.05, Kruskal-Wallis test). Mean PCT was 773.57 ± 64 msn in strabismic eyes, 771.25 ± 58 msn in anisometropic eyes, 778.00 ± 72 msn in non-amblyopic fellow eyes, and 774.75 ± 69 msn in control eyes. The differences among the amblyopic eyes, its fellow and control eyes were not statistically significant (p > 0.05, Kruskal-Wallis test). In this study, we investigated morphological and functional differences among amblyopic eyes, non-amblyopic fellow eyes and controls by using SD-OCT and PCT. We did not find anatomical or functional changes in amblyopic eyes.

  7. The Cost-effectiveness of Welcome to Medicare Visual Acuity Screening and a Possible Alternative Welcome to Medicare Eye Evaluation Among Persons Without Diagnosed Diabetes Mellitus

    PubMed Central

    Rein, David B.; Wittenborn, John S.; Zhang, Xinzhi; Hoerger, Thomas J.; Zhang, Ping; Klein, Barbara Eden Kobrin; Lee, Kris E.; Klein, Ronald; Saaddine, Jinan B.

    2013-01-01

    Objective To estimate the cost-effectiveness of visual acuity screening performed in primary care settings and of dilated eye evaluations performed by an eye care professional among new Medicare enrollees with no diagnosed eye disorders. Medicare currently reimburses visual acuity screening for new enrollees during their initial preventive primary care health check, but dilated eye evaluations may be a more cost-effective policy. Design Monte Carlo cost-effectiveness simulation model with a total of 50 000 simulated patients with demographic characteristics matched to persons 65 years of age in the US population. Results Compared with no screening policy, dilated eye evaluations increased quality-adjusted life-years (QALYs) by 0.008 (95% credible interval [CrI], 0.005–0.011) and increased costs by $94 (95% CrI, −$35 to $222). A visual acuity screening increased QALYs in less than 95% of the simulations (0.001 [95% CrI, −0.002 to 0.004) and increased total costs by $32 (95% CrI, −$97 to $159) per person. The incremental cost-effectiveness ratio of a visual acuity screening and an eye examination compared with no screening were $29 000 and $12 000 per QALY gained, respectively. At a willingness-to-pay value of $15 000 or more per QALY gained, a dilated eye evaluation was the policy option most likely to be cost-effective. Conclusions The currently recommended visual acuity screening showed limited efficacy and cost-effectiveness compared with no screening. In contrast, a new policy of reimbursement for Welcome to Medicare dilated eye evaluations was highly cost-effective. PMID:22232367

  8. Evaluation of eyes with relative pupillary block by indentation ultrasound biomicroscopy gonioscopy.

    PubMed

    Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka

    2004-03-01

    To investigate changes in anterior chamber angle configuration with indentation ultrasound biomicroscopy gonioscopy of relative pupillary block (RPB). Cross-sectional study. This study included 26 eyes of 26 patients with RPB. We determined angle opening distance 500 and angle recess area using indentation ultrasound biomicroscopy gonioscopy and compared a small-sized standard eye cup with a new eye cup with an area for inducing pressure. Indentation ultrasound biomicroscopy images documented concavity of the iris in eyes with RPB. Both the new and the small standard eye cups widened the anterior chamber angle significantly (P <.0001) without causing corneal damage. Angle changes were significantly greater for the new eye cup design. Indentation ultrasound biomicroscopy gonioscopy is a useful technique for observation and diagnosis of RPB. Using a small standard or the newly designed eye cup, the procedure can be performed easily and without causing corneal damage.

  9. Diquafosol sodium ophthalmic solution for the treatment of dry eye: clinical evaluation and biochemical analysis of tear composition.

    PubMed

    Shigeyasu, Chika; Yamada, Masakazu; Akune, Yoko; Tsubota, Kazuo

    2015-11-01

    To evaluate the clinical efficacy of 3% diquafosol sodium ophthalmic solution for dry eye, and to analyze the concentration of tear proteins and mucin-like substances after the treatment. Fifty eyes of 25 patients with dry eye syndrome were prospectively enrolled. The patients were treated with diquafosol solution at a dose of 1 drop in each eye 6 times daily for 4 weeks. The parameters of clinical efficacy were tear osmolarity, tear breakup time (BUT), fluorescein staining scores for the cornea and conjunctiva, Schirmer test values, and subjective symptoms evaluated using the ocular surface disease index (OSDI). Tears collected with Schirmer test strips were analyzed by high-performance liquid chromatography, and the concentrations of the total protein and the 4 major tear proteins, namely, secretory IgA, lactoferrin, lipocalin-1, lysozyme, and N-acetyl-neuraminic acid (Neu5Ac), were measured. Neu5Ac is a major sialic acid, a marker of secretory mucins. The BUT, keratoconjunctival staining scores, and Schirmer test values were improved with statistical significance after the treatment with diquafosol solution, while changes in the other parameters, including tear osmolarity, corneal staining scores, and OSDI scores were not significant. The Neu5Ac concentration was significantly increased, which was not accompanied by changes in tear proteins. Topical application of diquafosol significantly improved the clinical parameters of the BUT, keratoconjunctival staining scores, and Schirmer test values and was accompanied by increased sialic acid content in the tears of patients with dry eye.

  10. The Minnesota Grading System of eye bank eyes for age-related macular degeneration.

    PubMed

    Olsen, Timothy W; Feng, Xiao

    2004-12-01

    The Minnesota Grading System (MGS) is a method to evaluate human eye bank eyes and determine the level of age-related macular degeneration (AMD), by using criteria and definitions from the Age-Related Eye Disease Study (AREDS). Donor eyes (108 pairs) from the Minnesota Lions Eye Bank were cut circumferentially at the pars plana to remove the anterior segment. A 1000 +/- 2.5-microm ruby sphere was placed on the optic nerve as a size reference. A digital, high-resolution, color macular photograph was taken through a dissecting microscope. The neurosensory retina was removed from one globe of the pair. The underlying retinal pigment epithelium was rephotographed, localizing the fovea with a proportional triangle. A grid was superimposed in the macular photographs and images were graded according to AREDS criteria. Twenty pairs were dissected bilaterally and graded for symmetry. Eighty-eight globes were graded into one of four MGS categories. Nineteen (95%) of 20 globes had symmetric grades. The MGS provides a methodology to grade donor tissue from eye bank eyes to correspond to the AREDS classification system. Donor tissue may be used for subsequent molecular analysis, including genomics and proteomics.

  11. Health systems analysis of eye care services in Zambia: evaluating progress towards VISION 2020 goals.

    PubMed

    Bozzani, Fiammetta Maria; Griffiths, Ulla Kou; Blanchet, Karl; Schmidt, Elena

    2014-02-28

    VISION 2020 is a global initiative launched in 1999 to eliminate avoidable blindness by 2020. The objective of this study was to undertake a situation analysis of the Zambian eye health system and assess VISION 2020 process indicators on human resources, equipment and infrastructure. All eye health care providers were surveyed to determine location, financing sources, human resources and equipment. Key informants were interviewed regarding levels of service provision, management and leadership in the sector. Policy papers were reviewed. A health system dynamics framework was used to analyse findings. During 2011, 74 facilities provided eye care in Zambia; 39% were public, 37% private for-profit and 24% owned by Non-Governmental Organizations. Private facilities were solely located in major cities. A total of 191 people worked in eye care; 18 of these were ophthalmologists and eight cataract surgeons, equivalent to 0.34 and 0.15 per 250,000 population, respectively. VISION 2020 targets for inpatient beds and surgical theatres were met in six out of nine provinces, but human resources and spectacles manufacturing workshops were below target in every province. Inequalities in service provision between urban and rural areas were substantial. Shortage and maldistribution of human resources, lack of routine monitoring and inadequate financing mechanisms are the root causes of underperformance in the Zambian eye health system, which hinder the ability to achieve the VISION 2020 goals. We recommend that all VISION 2020 process indicators are evaluated simultaneously as these are not individually useful for monitoring progress.

  12. Proposal For A Practical Method For Evaluating Complaints Of Eye Discomfort Arising From Clerical Work

    NASA Astrophysics Data System (ADS)

    Stone, Peter T.

    1982-02-01

    A brief review is made of the major factors that are likely to cause eye discomfort from clerical work in traditional office environments. A procedure is proposed whereby cases of complaint may be systematically investigated. Methods are suggested for making a fairly quick evaluation of the task characteristics and the lighting conditions and it is suggested that measurements of the thermal characteristics of the environment also be carried out. In order to complete the investigation, it is necessary to obtain a person's subjective responses to the environment, using a suitably prepared questionairre, and for an eye examination to be performed by an ophthalmic optician.

  13. Automated grading system for evaluation of ocular redness associated with dry eye.

    PubMed

    Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B

    2013-01-01

    We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0-4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as "horizontality"). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R - 0.83G - 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. The agreement (both Pearson's and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a given image has 100% repeatability and zero

  14. Automated grading system for evaluation of ocular redness associated with dry eye

    PubMed Central

    Rodriguez, John D; Johnston, Patrick R; Ousler, George W; Smith, Lisa M; Abelson, Mark B

    2013-01-01

    Background We have observed that dry eye redness is characterized by a prominence of fine horizontal conjunctival vessels in the exposed ocular surface of the interpalpebral fissure, and have incorporated this feature into the grading of redness in clinical studies of dry eye. Aim To develop an automated method of grading dry eye-associated ocular redness in order to expand on the clinical grading system currently used. Methods Ninety nine images from 26 dry eye subjects were evaluated by five graders using a 0–4 (in 0.5 increments) dry eye redness (Ora Calibra™ Dry Eye Redness Scale [OCDER]) scale. For the automated method, the Opencv computer vision library was used to develop software for calculating redness and horizontal conjunctival vessels (noted as “horizontality”). From original photograph, the region of interest (ROI) was selected manually using the open source ImageJ software. Total average redness intensity (Com-Red) was calculated as a single channel 8-bit image as R – 0.83G – 0.17B, where R, G and B were the respective intensities of the red, green and blue channels. The location of vessels was detected by normalizing the blue channel and selecting pixels with an intensity of less than 97% of the mean. The horizontal component (Com-Hor) was calculated by the first order Sobel derivative in the vertical direction and the score was calculated as the average blue channel image intensity of this vertical derivative. Pearson correlation coefficients, accuracy and concordance correlation coefficients (CCC) were calculated after regression and standardized regression of the dataset. Results The agreement (both Pearson’s and CCC) among investigators using the OCDER scale was 0.67, while the agreement of investigator to computer was 0.76. A multiple regression using both redness and horizontality improved the agreement CCC from 0.66 and 0.69 to 0.76, demonstrating the contribution of vessel geometry to the overall grade. Computer analysis of a

  15. Ultrasonography of the eye and orbit.

    PubMed

    Eisenberg, H M

    1985-11-01

    The eye and orbit are excellent subjects for ultrasonic evaluation. Examination and interpretation are relatively simple procedures. The normal ultrasonic anatomy of the eye and orbit is presented. Some examples of ocular and orbital pathology are discussed also.

  16. Evaluation of the onset and duration of effect of azelastine eye drops (0.05%) versus placebo in patients with allergic conjunctivitis using an allergen challenge model.

    PubMed

    Friedlaender, M H; Harris, J; LaVallee, N; Russell, H; Shilstone, J

    2000-12-01

    The trial evaluated the effectiveness of the investigational antihistaminic and antiallergic compound Azelastine Eye Drops (AZE) in the treatment of allergic conjunctivitis using an allergen challenge model. Randomized, double-blind, placebo-controlled, paired-eye study. Adults with a history of allergic conjunctivitis (>/=2 years) who were asymptomatic throughout the trial, had a positive skin test (cat dander, grass, or ragweed pollen within the last year), and had a positive conjunctival reaction (score 2+ or more for itching and redness in both eyes on a 0-4 scale) during two separate conjunctival provocation tests (CPT) before randomization. Eighty patients underwent a 2-week screening period (visits 1 and 2) that included a CPT during visit 1 to establish the allergen threshold dose and a second confirmatory CPT performed at visit 2. Eye symptom assessments for itching (evaluated by patient) and conjunctival redness (evaluated by physician) were performed 5 and 10 minutes after CPT using a 5-point scale (from 0 = none to 4+ = severe). Qualified patients were randomized to receive one drop of AZE (0.015 mg of azelastine hydrochloride) in one eye and one drop of placebo in the other eye 20 minutes before CPT at visit 3 (onset) and 8 or 10 hours before CPT at visit 4 (duration). Individual severity scores for itching (evaluated by patient) and conjunctival redness (evaluated by physician) for each eye at 3, 5, and 10 minutes after CPT at visits 3 and 4 using a 5-point scale (0 = none to 4+ = very severe). Each of the 80 randomized patients completed the trial. Mean itching and conjunctival redness scores at visit 3 (onset) were significantly lower (P: < 0.001) in the AZE-treated eyes than in the placebo-treated eyes. At visit 4 (duration), mean itching and conjunctival redness scores (P: eyes than in the placebo-treated eyes

  17. Prospective, randomized, controlled comparison of SYSTANE UD eye drops versus VISINE INTENSIV 1% EDO eye drops for the treatment of moderate dry eye.

    PubMed

    Jacobi, Christina; Kruse, Friedrich E; Cursiefen, Claus

    2012-12-01

    The aim of this prospective, randomized, clinical, single-center study was to compare the safety and efficacy of 2 ocular surface lubricant eye drops: preservative-free hydroxypropyl (HP)-Guar (SYSTANE UD(®)) eye drops versus preservative-free Tamarindus indica seed polysaccharide (TSP) 1% (VISINE INTENSIV 1% EDO(®)) eye drops. Fifty-six eyes of 28 patients with moderate keratoconjunctivitis sicca (DEWS severity level 2) were enrolled in the trial. Patients were randomized for 2 treatment groups (SYSTANE UD eye drops vs. VISINE INTENSIV 1% EDO eye drops). The eye drops in both groups were applied 5 times per day for 3 months. Statistical analyses were performed using Statistica™ software (Mann-Whitney U-test and Wilcoxon test). P-Values<0.05 were considered significant. After 3 months of treatment the patients of both groups had subjective benefit in the relief of symptoms of dry eye disease evaluated by the Ocular Surface Disease Index (OSDI) questionnaire score. Patients treated with HP-Guar and TSP showed improvements in tear film stability measured by tear break-up time (TBUT), which are statistically significant in the HP-Guar group (P=0.02). The results of this clinical trial show improvements of symptoms and signs in patients with moderate dry eye after the consistent use of preservative-free HP-Guar and TSP lubricant eye drops. Both artificial tear formulations produce amelioration in tear film stability improving eye conditions and patient quality of life. HP-Guar seems to be slightly more effective in improving ocular surface protection by decreasing tear film evaporation.

  18. Health systems analysis of eye care services in Zambia: evaluating progress towards VISION 2020 goals

    PubMed Central

    2014-01-01

    Background VISION 2020 is a global initiative launched in 1999 to eliminate avoidable blindness by 2020. The objective of this study was to undertake a situation analysis of the Zambian eye health system and assess VISION 2020 process indicators on human resources, equipment and infrastructure. Methods All eye health care providers were surveyed to determine location, financing sources, human resources and equipment. Key informants were interviewed regarding levels of service provision, management and leadership in the sector. Policy papers were reviewed. A health system dynamics framework was used to analyse findings. Results During 2011, 74 facilities provided eye care in Zambia; 39% were public, 37% private for-profit and 24% owned by Non-Governmental Organizations. Private facilities were solely located in major cities. A total of 191 people worked in eye care; 18 of these were ophthalmologists and eight cataract surgeons, equivalent to 0.34 and 0.15 per 250,000 population, respectively. VISION 2020 targets for inpatient beds and surgical theatres were met in six out of nine provinces, but human resources and spectacles manufacturing workshops were below target in every province. Inequalities in service provision between urban and rural areas were substantial. Conclusion Shortage and maldistribution of human resources, lack of routine monitoring and inadequate financing mechanisms are the root causes of underperformance in the Zambian eye health system, which hinder the ability to achieve the VISION 2020 goals. We recommend that all VISION 2020 process indicators are evaluated simultaneously as these are not individually useful for monitoring progress. PMID:24575919

  19. An eye tracking system for monitoring face scanning patterns reveals the enhancing effect of oxytocin on eye contact in common marmosets.

    PubMed

    Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito

    2017-09-01

    Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. A novel evaluation of two related and two independent algorithms for eye movement classification during reading.

    PubMed

    Friedman, Lee; Rigas, Ioannis; Abdulin, Evgeny; Komogortsev, Oleg V

    2018-05-15

    Nystrӧm and Holmqvist have published a method for the classification of eye movements during reading (ONH) (Nyström & Holmqvist, 2010). When we applied this algorithm to our data, the results were not satisfactory, so we modified the algorithm (now the MNH) to better classify our data. The changes included: (1) reducing the amount of signal filtering, (2) excluding a new type of noise, (3) removing several adaptive thresholds and replacing them with fixed thresholds, (4) changing the way that the start and end of each saccade was determined, (5) employing a new algorithm for detecting PSOs, and (6) allowing a fixation period to either begin or end with noise. A new method for the evaluation of classification algorithms is presented. It was designed to provide comprehensive feedback to an algorithm developer, in a time-efficient manner, about the types and numbers of classification errors that an algorithm produces. This evaluation was conducted by three expert raters independently, across 20 randomly chosen recordings, each classified by both algorithms. The MNH made many fewer errors in determining when saccades start and end, and it also detected some fixations and saccades that the ONH did not. The MNH fails to detect very small saccades. We also evaluated two additional algorithms: the EyeLink Parser and a more current, machine-learning-based algorithm. The EyeLink Parser tended to find more saccades that ended too early than did the other methods, and we found numerous problems with the output of the machine-learning-based algorithm.

  1. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    PubMed

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  2. Effect of Education Sessions of a Structured School Eye Screening Programme on Indian Schoolteachers' Knowledge and Responsibility for Children's Eye Health

    ERIC Educational Resources Information Center

    Thummalapalli, Rohit; Williams, Jachin D.; Khoshnood, Kaveh; Salchow, Daniel J.; Forster, Susan H.

    2013-01-01

    Objective: To evaluate the effect of education sessions on Indian schoolteacher awareness of childhood eye health issues, responsibility for children's eye health, and successful participation in a teacher-led eye screening health intervention programme in primary schools aimed at addressing avoidable childhood blindness in India. Design:…

  3. Recent advances in laser in situ keratomileusis-associated dry eye.

    PubMed

    Xie, Wenjia

    2016-03-01

    Dry eye is the most common complication after laser in situ keratomileusis (LASIK). The major cause of LASIK-associated dry eye is corneal nerve damage. Early identification and treatment of post-operative dry eye are essential to prevent further ocular surface damage. This article reviews the recent studies of LASIK-associated dry eye, including clinical features, aetiology, risk factors, evaluations and treatment. The applications of novel technologies in LASIK-associated dry eye evaluation like anterior segment spectral-domain optical coherence tomography (SD-OCT) and corneal confocal microscopy are also introduced in this review. © 2016 Optometry Australia.

  4. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Paleocene to Middle Miocene planktic foraminifera of the southwestern Salisbury Embayment, Virginia and Maryland: biostratigraphy, allostratigraphy, and sequence stratigraphy

    USGS Publications Warehouse

    Poag, C.W.; Commeau, J.A.

    1995-01-01

    The Paleocene to Middle Miocene sedimentary fill of the southwestern Salisbury Embayment contains a fragmental depositional record, interrupted by numerous local diastems and regional unconformities. Using planktic foraminiferal biostratigraphy, 15 unconformity-bounded depositional units have been identified, assigned to six formations and seven alloformations previously recognized in the embayment. The units correlate with second- and third-order sequences of the Exxon sequence stratigraphy model, and include transgressive and highstand systems tracts. Alloformation, formation, and sequence boundaries are marked by abrupt, scoured, burrowed, erosional surfaces, which display lag deposits, biostratigraphic gaps, and intense reworking of microfossils above and below the boundaries.Paleocene deposits represent the upper parts of upper Pleocene Biochronozones P4 and P5, and rest uncomformably  on Cretaceous sedimentary beds of various ages (Maastrichtian to Albian). Lower Eocene deposits represent parts of Biochronozones P6 and P9. Middle Eocene strata represent mainly parts of Biochronozones P11, P12, and P14. Upper Eocene sediments include parts of Biochronozones P15, P16, and P17. Oligocene deposits encompass parts of Biochronozones. N4b to N7 undifferentiated, P21a, and, perhaps, N4a. Lower Miocene deposits encompass parts of Biochronozones N4b to N7 undifferentiated. Middle Miocene strata represent mainly parts of Biochronorones N8, N9, and N10.Nine plates of scanning electron micrographs illustrate the principal planktic foraminifera used to establish the biostratigraphic framework. Two new informal formine of Praeterenuitella praegemma Li, 1987, are introduced.

  6. Dry eyes: etiology and management.

    PubMed

    Latkany, Robert

    2008-07-01

    Until recently, the cause of dry eye syndrome was uncertain and the treatment was palliative. Since discovering that dry eyes are caused by inflammation, there has been an abundance of research focusing on anti-inflammatory therapies, other contributing causes, and better diagnostic testing. This review summarizes some of the interesting published research on ocular surface disease over the past year. The definition of dry eye now highlights the omnipresent symptom of blurry vision. The re-evaluation of ocular surface staining, tear meniscus height, and visual change will allow for a better diagnosis and understanding of dry eyes. Punctal plugs, and oral and topical anti-inflammatory use will strengthen our arsenal against ocular surface disease. Major progress has occurred in the past few years in gaining a better understanding of the etiology of dry eye syndrome, which will inevitably lead to more effective therapeutic options.

  7. The injured eye

    PubMed Central

    Scott, Robert

    2011-01-01

    Eye injuries come at a high cost to society and are avoidable. Ocular blast injuries can be primary, from the blast wave itself; secondary, from fragments carried by the blast wind; tertiary; due to structural collapse or being thrown against a fixed object; or quaternary, from burns and indirect injuries. Ballistic eye protection significantly reduces the incidence of eye injuries and should be encouraged from an early stage in Military training. Management of an injured eye requires meticulous history taking, evaluation of vision that measures the acuity and if there is a relative pupillary defect as well as careful inspection of the eyes, under anaesthetic if necessary. A lateral canthotomy with cantholysis should be performed immediately if there is a sight-threatening retrobulbar haemorrhage. Systemic antibiotics should be prescribed if there is a suspected penetrating or perforating injury. A ruptured globe should be protected by an eye shield. Primary repair of ruptured globes should be performed in a timely fashion. Secondary procedures will often be required at a later date to achieve sight preservation. A poor initial visual acuity is not a guarantee of a poor final result. The final result can be predicted after approximately 3–4 weeks. Future research in eye injuries attempts to reduce scarring and neuronal damage as well as to promote photoreceptor rescue, using post-transcriptional inhibition of cell death pathways and vaccination to promote neural recovery. Where the sight has been lost sensory substitution of a picture from a spectacle mounted video camera to the touch receptors of the tongue can be used to achieve appreciation of the outside world. PMID:21149360

  8. Evaluation of the anterior chamber angle in Asian Indian eyes by ultrasound biomicroscopy and gonioscopy.

    PubMed

    Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod

    2006-09-01

    To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P < 0.001). The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P < 0.001) respectively. The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.

  9. A field evaluation of the Eye-Closure Interview with witnesses of serious crimes.

    PubMed

    Vredeveldt, Annelies; Tredoux, Colin G; Nortje, Alicia; Kempen, Kate; Puljević, Cheneal; Labuschagne, Gérard N

    2015-04-01

    Laboratory research shows that eye-closure during memory retrieval improves both the amount and the factual accuracy of memory reports about witnessed events. Based on these findings, we developed the Eye-Closure Interview, and examined its feasibility (in terms of compliance with the instructions) and effectiveness (in terms of the quantity and quality of reported information) in eyewitness interviews conducted by the South African Police Service. Police interviewers from the Facial Identification Unit were randomly assigned to receive Eye-Closure Interview training or no training. We analyzed 95 interviews with witnesses of serious crimes (including robbery, rape, and murder), some of whom were instructed to close their eyes during salient parts of the interview. Witnesses in the control condition rarely spontaneously closed their eyes, but witnesses in the Eye-Closure Interview condition kept their eyes closed during 97% of their descriptions, suggesting that the Eye-Closure Interview would be easy to implement in a field setting. Although witnesses who closed their eyes did not remember more information overall, the information they provided was considered to be of significantly greater forensic relevance (as reflected in 2 independent blind assessments, 1 by a senior police expert and 1 by a senior researcher). Thus, based on the findings from this field study and from previous laboratory research, we conclude that implementation of the Eye-Closure Interview in witness interviews would help police interviewers to elicit more valuable information from witnesses, which could be relevant to the police investigation and/or in court. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  10. Specialized moisture retention eyewear for evaporative dry eye.

    PubMed

    Waduthantri, Samanthila; Tan, Chien Hua; Fong, Yee Wei; Tong, Louis

    2015-05-01

    To evaluate the suitablity of commercially available moisture retention eyewear for treating evaporative dry eye. Eleven patients with evaporative dry eyes were prescibed moisture retention eyewear for 3 months in addition to regular lubricant eye drops. Frequency and severity of dry eye symptoms, corneal fluorescein staining and tear break up time (TBUT) were evaluated at baseline and 3-month post-treatment. Main outcome measure was global symptom score (based on severity and frequency of dry eye symptoms on a visual analog scale) and secondary outcomes were changes in sectoral corneal fluorescein staining and tear break up time (TBUT) from pre-treatment level. There was a significant improvement in dry eye symptoms after using moisture retention eyewear for 3 months (p < 0.05). Corneal fluorescein staining in all five zones of the cornea in both eyes improved significantly (p < 0.05). There was no significant improvement in TBUT. Patients used ocular lubricants less frequently (p < 0.05) compared to the commencement of the study. Patients found moisture retention eyewear to be useful in relieving dry eye symptoms in windy, air-conditioned environments or when doing vision-related daily tasks. This study shows that moisture retention eyewear might be a valuable adjunct in management of evaporative dry eye and this new design of commercially available eyewear could have a good acceptability rate.

  11. Live Speech Driven Head-and-Eye Motion Generators.

    PubMed

    Le, Binh H; Ma, Xiaohan; Deng, Zhigang

    2012-11-01

    This paper describes a fully automated framework to generate realistic head motion, eye gaze, and eyelid motion simultaneously based on live (or recorded) speech input. Its central idea is to learn separate yet interrelated statistical models for each component (head motion, gaze, or eyelid motion) from a prerecorded facial motion data set: 1) Gaussian Mixture Models and gradient descent optimization algorithm are employed to generate head motion from speech features; 2) Nonlinear Dynamic Canonical Correlation Analysis model is used to synthesize eye gaze from head motion and speech features, and 3) nonnegative linear regression is used to model voluntary eye lid motion and log-normal distribution is used to describe involuntary eye blinks. Several user studies are conducted to evaluate the effectiveness of the proposed speech-driven head and eye motion generator using the well-established paired comparison methodology. Our evaluation results clearly show that this approach can significantly outperform the state-of-the-art head and eye motion generation algorithms. In addition, a novel mocap+video hybrid data acquisition technique is introduced to record high-fidelity head movement, eye gaze, and eyelid motion simultaneously.

  12. Contribution of malocclusion and female facial attractiveness to smile esthetics evaluated by eye tracking.

    PubMed

    Richards, Michael R; Fields, Henry W; Beck, F Michael; Firestone, Allen R; Walther, Dirk B; Rosenstiel, Stephen; Sacksteder, James M

    2015-04-01

    There is disagreement in the literature concerning the importance of the mouth in overall facial attractiveness. Eye tracking provides an objective method to evaluate what people see. The objective of this study was to determine whether dental and facial attractiveness alters viewers' visual attention in terms of which area of the face (eyes, nose, mouth, chin, ears, or other) is viewed first, viewed the greatest number of times, and viewed for the greatest total time (duration) using eye tracking. Seventy-six viewers underwent 1 eye tracking session. Of these, 53 were white (49% female, 51% male). Their ages ranged from 18 to 29 years, with a mean of 19.8 years, and none were dental professionals. After being positioned and calibrated, they were shown 24 unique female composite images, each image shown twice for reliability. These images reflected a repaired unilateral cleft lip or 3 grades of dental attractiveness similar to those of grades 1 (near ideal), 7 (borderline treatment need), and 10 (definite treatment need) as assessed in the aesthetic component of the Index of Orthodontic Treatment Need (AC-IOTN). The images were then embedded in faces of 3 levels of attractiveness: attractive, average, and unattractive. During viewing, data were collected for the first location, frequency, and duration of each viewer's gaze. Observer reliability ranged from 0.58 to 0.92 (intraclass correlation coefficients) but was less than 0.07 (interrater) for the chin, which was eliminated from the study. Likewise, reliability for the area of first fixation was kappa less than 0.10 for both intrarater and interrater reliabilities; the area of first fixation was also removed from the data analysis. Repeated-measures analysis of variance showed a significant effect (P <0.001) for level of attractiveness by malocclusion by area of the face. For both number of fixations and duration of fixations, the eyes overwhelmingly were most salient, with the mouth receiving the second most

  13. Measuring eye movements during locomotion: filtering techniques for obtaining velocity signals from a video-based eye monitor

    NASA Technical Reports Server (NTRS)

    Das, V. E.; Thomas, C. W.; Zivotofsky, A. Z.; Leigh, R. J.

    1996-01-01

    Video-based eye-tracking systems are especially suited to studying eye movements during naturally occurring activities such as locomotion, but eye velocity records suffer from broad band noise that is not amenable to conventional filtering methods. We evaluated the effectiveness of combined median and moving-average filters by comparing prefiltered and postfiltered records made synchronously with a video eye-tracker and the magnetic search coil technique, which is relatively noise free. Root-mean-square noise was reduced by half, without distorting the eye velocity signal. To illustrate the practical use of this technique, we studied normal subjects and patients with deficient labyrinthine function and compared their ability to hold gaze on a visual target that moved with their heads (cancellation of the vestibulo-ocular reflex). Patients and normal subjects performed similarly during active head rotation but, during locomotion, patients held their eyes more steadily on the visual target than did subjects.

  14. Mechanistic-based non-animal assessment of eye toxicity: Inflammatory profile of human keratinocytes cells after exposure to eye damage/irritant agents.

    PubMed

    da Silva, Artur Christian Garcia; Chialchia, Adrienny Rodrigues; de Ávila, Renato Ivan; Valadares, Marize Campos

    2018-06-25

    Eye toxicity is a mandatory parameter in human risk and safety evaluation for products including chemicals, pesticides, medicines and cosmetics. Historically, this endpoint has been evaluated using the Draize rabbit eye test, an in vivo model that was never formally validated. Due to advances in scientific knowledge, economic and ethical issues, non-animal methods based on mechanisms of toxicity are being developed and validated for increasing the capability of these models to predict eye toxicity. In this study, the Cytometric Bead Array (CBA) and ELISA assays were used to evaluate the inflammatory cytokine profile produced by HaCaT human keratinocytes after exposure to chemicals with different UN GHS eye toxicity classifications, aiming to stablish a correlation between inflammatory endpoints and eye toxicity (damage/irritation) potential. As a first step, cytotoxic profile of the chemicals, including 3 non-irritants and 10 eye toxicants (GHS Category 1, 2A and 2B), was evaluated after 24 h exposure using MTT assay and Inhibitory Concentration of 20% of cell viability (IC 20 ) was calculated for each chemical. Then, the cells were exposed to these chemicals at IC 20 for 24 h and supernatants and cell lysates were analyzed by CBA assay for quantification of the following cytokines: IL-6, IL-8, IL-10, IL-1β, TNF and IL-12p70. Regarding cytotoxicity evaluation, chemicals showed different cytotoxicity profiles and data demonstrated no correlation with their UN GHS classification. Among the cytokines evaluated, IL-1β production has changed after exposure and such alterations were confirmed by quantification employing ELISA method. The higher intracellular levels of IL-1β were found in GHS Category 1 chemicals, followed by Category 2A and 2B, while non irritants did not induce such increase. Thus, these findings show that IL-1β measurement, using HaCaT model, can be a considerable biomarker to identify chemicals according to their potential in promote eye

  15. EVALUATION OF EYE LENS DOSE TO WORKERS IN THE STEAM GENERATOR AT THE KOREAN OPTIMIZED POWER REACTOR 1000.

    PubMed

    Maeng, Sung Jun; Kim, Jinhwan; Cho, Gyuseong

    2018-03-15

    ICRP (2011) revised the dose limit to the eye lens to 20 mSv/y based on a recent epidemiological study of radiation-induced cataracts. Maintenance of steam generators at nuclear power plants is one of the highest radiation-associated tasks within a non-uniform radiation field. This study aims to evaluate eye lens doses in the steam generators of the Korean OPR1000 design. The source term was characterized based on the CRUD-specific activity, and both the eye lens dose and organ dose were simulated using MCNP6 combined with an ICRP voxel phantom and a mesh phantom, respectively. The eye lens dose was determined to be 5.39E-02-9.43E-02 Sv/h, with a negligible effect by beta particles. As the effective dose was found to be 0.81-1.21 times the lens equivalent dose depending on the phantom angles, the former can be used to estimate the lens dose in the SG of the OPR1000 for radiation monitoring purposes.

  16. Paralysis of the orbicularis muscle of the eye using botulinum toxin type A in the treatment for dry eye.

    PubMed

    Serna-Ojeda, Juan Carlos; Nava-Castaneda, Angel

    2017-03-01

    To evaluate the efficacy of botulinum toxin type A injection to cause orbicularis eyelid muscle paralysis to improve dry eye signs and symptoms. A prospective, randomized, comparative eye-to-eye and interventional study was performed. Patients with dry eye symptoms and positive fluorescein corneal staining were included. Randomly one eyelid received a subcutaneous injection of botulinum toxin in the medial orbicularis muscle portion of the lower eyelid, and the other eye received placebo. The subjective evaluation was achieved with a questionnaire assessing symptoms, quality of vision and ocular comfort level. The objective evaluation included the measurement of the tear film break-up time (TBUT), Schirmer's test and corneal and conjunctival staining. Twenty patients were included with a mean age of 59.5 years. Two weeks after the botulinum toxin injection, all patients showed a decrease in the horizontal movement of the lower eyelid when blinking. The eyes in the active treatment group showed better scores compared with the sham group in four symptoms 4 weeks after the treatment. The TBUT was higher at 1 and 3 months in the active treatment group. The corneal and conjunctival staining were significantly lower in the active treatment group at 1 and 3 months, and the Schirmer's test showed better measurements in the same group at 2 weeks, 1 month and 3 months. There were no adverse events reported. The injection of botulinum toxin A in the medial part of the lower eyelid is an effective and safe procedure that temporally improves some of the signs and symptoms of patients with dry eye. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Toxicity evaluation of the photoprotective compound LQFM048: Eye irritation, skin toxicity and genotoxic endpoints.

    PubMed

    de Ávila, Renato Ivan; de Sousa Vieira, Marcelo; Gaeti, Marilisa Pedroso Nogueira; Moreira, Larissa Cleres; de Brito Rodrigues, Laís; de Oliveira, Gisele Augusto Rodrigues; Batista, Aline Carvalho; Vinhal, Daniela Cristina; Menegatti, Ricardo; Valadares, Marize Campos

    2017-02-01

    A new molecule, LQFM048, originally designed through molecular hybridization using green chemistry approach, is in development as a photoprotective agent. Eye irritation, skin toxicity and genotoxicity evaluations are mandatory for predicting health risks. In this context, the purpose of this study was to investigate the eye irritation potential of LQFM048 by combining Short Time Exposure (STE), Bovine Corneal Opacity and Permeability (BCOP) associated with corneal histomorphometry and Hen's Egg Test-Chorioallantoic Membrane (HET-CAM). Additionally, skin toxicity was evaluated by interleukin-18 production in the HaCaT keratinocyte, Local Lymph Node Assay (LLNA:BrdU-ELISA) method, 3T3 Neutral red uptake (NRU) assay and in vivo phototoxicity test. Genotoxic potential of LQFM048 was also analyzed by cytokinesis-block micronucleus assay (MNvit test-cytoB) in HepG2 cells. Our results showed that LQFM048 did not induce eye irritation and it was classified as UN GHS No Category for both STE and BCOP assays and non-irritating for HET-CAM test. LQFM048 showed non-potential skin sensitization with stimulation index (SI=0.7) in the LLNA:BrdU-ELISA method. Corroborating in vivo tests, it did not promote significant cytotoxicity in HaCaT cells and it showed similar levels of IL-18 when compared to control. Furthermore, LQFM048 induced non-phototoxic potential with photo-irritation factor (PIF) and mean photo effect (MPE) of 1 and -0.138, respectively, for 3T3 cells. Similarly, it was not phototoxic for in vivo testing with or without exposure to UVA, showing SI values of 1 and 1.2, respectively. The micronucleus test showed that LQFM048 was not genotoxic, under the conditions tested.In conclusion, LQFM048, a heterocyclic compound obtained through an environmentally acceptable simple synthetic route, seems to be safe for human use, especially for the development of a new sunscreen product, since it is neither an eye irritant, nor a contact allergen, nor mutagenic and nor

  18. A new experimental device to evaluate eye ulcers using a multispectral electrical impedance technique

    NASA Astrophysics Data System (ADS)

    Bellotti, Mariela I.; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J.

    2011-07-01

    We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.

  19. A new experimental device to evaluate eye ulcers using a multispectral electrical impedance technique.

    PubMed

    Bellotti, Mariela I; Bast, Walter; Berra, Alejandro; Bonetto, Fabián J

    2011-07-01

    We present a novel experimental technique to determine eye ulcers in animals using a spectral electrical impedance technique. We expect that this technique will be useful in dry eye syndrome. We used a sensor that is basically a platinum (Pt) microelectrode electrically insulated by glass from a cylindrical stainless steel counter-electrode. This sensor was applied to the naked eye of New Zealand rabbits (2.0-3.5 kg in weight). Whereas half of the eyes were normal (control), we applied to the remainder a few drops of 20% (v/v) alcohol to produce an ulcer in the eye. Using a multispectral electrical impedance system we measured ulcerated and control eyes and observed significant difference between normal and pathological samples. We also investigated the effects of different applied pressures and natural degradation of initially normal eyes as a function of time. We believe that this technique could be sufficiently sensitive and repetitive to help diagnose ocular surface diseases such as dry eye syndrome.

  20. Effect of diquafosol tetrasodium eye drop for persistent dry eye after laser in situ keratomileusis.

    PubMed

    Mori, Yosai; Nejima, Ryohei; Masuda, Ayami; Maruyama, Yoko; Minami, Keiichiro; Miyata, Kazunori; Amano, Shiro

    2014-07-01

    To evaluate the effect of diquafosol tetrasodium (DQS) for the treatment of persistent dry eye after laser in situ keratomileusis (LASIK). Miyata Eye Hospital, Miyazaki, Japan. Noncomparative case series. This prospective study included 30 eyes of 15 patients in whom dry eye had persisted for over 12 months after LASIK, and the symptoms had not improved with artificial tears and sodium hyaluronate treatment. In addition, treatment with DQS 3% eye drops, 6 times a day, was performed for 12 weeks. Best-corrected visual acuity, tear secretion with the Schirmer test, tear break-up time, and fluorescein and lissamine green staining scores on the cornea and conjunctiva were examined before and at 1, 4, and 12 weeks after the addition. A subjective questionnaire of 14 symptoms was also assessed before and 12 weeks after treatment. The fluorescein and lissamine green staining scores significantly improved over 12 weeks; however, the best-corrected visual acuity and tear secretion did not change. The symptoms of fatigue, dryness, grittiness, discomfort, difficulty in reading, and discomfort within the area of dryness improved after the additional DQS treatment. The DQS treatment improved the subjective and objective symptoms of persistent dry eye after LASIK. Increased mucin production because of the addition of DQS probably improved the tear film stability and reduced the symptoms of dry eye in patients who had persistent dry eye after LASIK.

  1. Retrospective Evaluation of a Teleretinal Screening Program in Detecting Multiple Nondiabetic Eye Diseases.

    PubMed

    Maa, April Y; Patel, Shivangi; Chasan, Joel E; Delaune, William; Lynch, Mary G

    2017-01-01

    Diabetic teleretinal screening programs have been utilized successfully across the world to detect diabetic retinopathy (DR) and are well validated. Less information, however, exists on the ability of teleretinal imaging to detect nondiabetic ocular pathology. This study performed a retrospective evaluation to assess the ability of a community-based diabetic teleretinal screening program to detect common ocular disease other than DR. A retrospective chart review of 1,774 patients who underwent diabetic teleretinal screening was performed. Eye clinic notes from the Veterans Health Administration's electronic medical record, Computerized Patient Record System, were searched for each of the patients screened through teleretinal imaging. When a face-to-face examination note was present, the physical findings were compared to those obtained through teleretinal imaging. Sensitivity, specificity, and positive and negative predictive values were calculated for suspicious nerve, cataract, and age-related macular degeneration. A total of 903 patients underwent a clinical examination. The positive predictive value was highest for cataract (100%), suspicious nerve (93%), and macular degeneration (90%). The negative predictive value and the percent agreement between teleretinal imaging and a clinical examination were over 90% for each disease category. A teleretinal imaging protocol may be used to screen for other common ocular diseases. It may be feasible to use diabetic teleretinal photographs to screen patients for other potential eye diseases. Additional elements of the eye workup may be added to enhance accuracy of disease detection. Further study is necessary to confirm this initial retrospective review.

  2. Usability Evaluation of Clinical Guidelines on the Web Using Eye-Tracker.

    PubMed

    Khodambashi, Soudabeh; Gilstad, Heidi; Nytrø, Øystein

    2016-01-01

    Publishing clinical guidelines (GLs) on the web increases their accessibility. However, evaluating their usability and understanding how users interact with the websites has been neglected. In this study we used Tobii eye-tracker to analyse users' interaction with five commercial and public GL sites popular in Norway (four in Norwegian and one English of US origin (UpToDate)). We measured number of clicks and usage rate for search functions, task completion time, users' objective and perception of task success rate. We also measured learning effect for inexperienced users. We found a direct correlation between participant's satisfaction regarding website usability and the time spent, number of mouse clicks and use of search function to obtain the desired results. Our study showed that users' perceived success rate was not reliable and GL publishers should evaluate their website regarding presentation format, layout, navigation bar and search function.

  3. Geometric adjustments to account for eye eccentricity in processing horizontal and vertical eye and head movement data

    NASA Technical Reports Server (NTRS)

    Huebner, W. P.; Paloski, W. H.; Reschke, M. F.; Bloomberg, J. J.

    1995-01-01

    Neglecting the eccentric position of the eyes in the head can lead to erroneous interpretation of ocular motor data, particularly for near targets. We discuss the geometric effects that eye eccentricity has on the processing of target-directed eye and head movement data, and we highlight two approaches to processing and interpreting such data. The first approach involves determining the true position of the target with respect to the location of the eyes in space for evaluating the efficacy of gaze, and it allows calculation of retinal error directly from measured eye, head, and target data. The second approach effectively eliminates eye eccentricity effects by adjusting measured eye movement data to yield equivalent responses relative to a specified reference location (such as the center of head rotation). This latter technique can be used to standardize measured eye movement signals, enabling waveforms collected under different experimental conditions to be directly compared, both with the measured target signals and with each other. Mathematical relationships describing these approaches are presented for horizontal and vertical rotations, for both tangential and circumferential display screens, and efforts are made to describe the sensitivity of parameter variations on the calculated results.

  4. Watery eyes

    MedlinePlus

    ... JavaScript. Watery eyes means you have too many tears draining from the eyes. Tears help keep the surface of the eye moist. ... the eye. Causes Your eyes are always making tears. These tears leave the eye through a small ...

  5. Eye aberration analysis with Zernike polynomials

    NASA Astrophysics Data System (ADS)

    Molebny, Vasyl V.; Chyzh, Igor H.; Sokurenko, Vyacheslav M.; Pallikaris, Ioannis G.; Naoumidis, Leonidas P.

    1998-06-01

    New horizons for accurate photorefractive sight correction, afforded by novel flying spot technologies, require adequate measurements of photorefractive properties of an eye. Proposed techniques of eye refraction mapping present results of measurements for finite number of points of eye aperture, requiring to approximate these data by 3D surface. A technique of wave front approximation with Zernike polynomials is described, using optimization of the number of polynomial coefficients. Criterion of optimization is the nearest proximity of the resulted continuous surface to the values calculated for given discrete points. Methodology includes statistical evaluation of minimal root mean square deviation (RMSD) of transverse aberrations, in particular, varying consecutively the values of maximal coefficient indices of Zernike polynomials, recalculating the coefficients, and computing the value of RMSD. Optimization is finished at minimal value of RMSD. Formulas are given for computing ametropia, size of the spot of light on retina, caused by spherical aberration, coma, and astigmatism. Results are illustrated by experimental data, that could be of interest for other applications, where detailed evaluation of eye parameters is needed.

  6. Relationships Between Meibomian Gland Loss and Age, Sex, and Dry Eye.

    PubMed

    Pult, Heiko

    2018-02-12

    This study evaluated relationships between meibomian gland loss (MGL) and age, sex, and dry eye. Dry eye and MGL of the lower eyelid was evaluated from 112 randomly selected subjects (66 women; mean age 62.8; SD ±15.7; and age range: 19-89 years) from Horst Riede GmbH, Weinheim, Germany. In addition, subjects were grouped into dry eye and non-dry eye by the Ocular Surface Disease Index (OSDI) score, lid-parallel conjunctival folds and non-invasive break-up time. Symptoms were evaluated by the OSDI. Meibography of the lower eyelid was performed using a Cobra camera (bon Optic, Lübeck, Germany), and images were analyzed by its digital grading tool. Data were analyzed by backward, multiple regression analyses and Pearson correlation. Analyzing all subjects, multiple regression analyses detected that age and dry eye status (dry eye diagnosis or OSDI) but not sex were significantly related to MGL. In both, non-dry eye (n=66) and dry eye subjects (n=46), dry eye status (OSDI) but not age or sex was significantly related to MGL. Ocular Surface Disease Index scores were significantly correlated with MGL, but this correlation was stronger among all subjects (Pearson correlation; r=0.536, P<0.001) and dry eye group subjects (r=0.520, P<0.001) than in non-dry eye group subjects (r=0.275, P=0.014). Dry eye group subjects showed significantly increased MGL of the lower eyelid. Age and dry eye status were related to MGL of the lower eyelid, but sex was not; dry eye status was the dominant factor.

  7. Eye Growth in Term- And Preterm-Born Eyes Modeled From Magnetic Resonance Images

    PubMed Central

    Munro, Robert J.; Fulton, Anne B.; Chui, Toco Y. P.; Moskowitz, Anne; Ramamirtham, Ramkumar; Hansen, Ronald M.; Prabhu, Sanjay P.; Akula, James D.

    2015-01-01

    Purpose. We generated a model of eye growth and tested it against an eye known to develop abnormally, one with a history of retinopathy of prematurity (ROP). Methods. We reviewed extant magnetic resonance images (MRIs) from term and preterm-born patients for suitable images (n = 129). We binned subjects for analysis based upon postmenstrual age at birth (in weeks) and ROP history (“Term” ≥ 37, “Premature” ≤ 32 with no ROP, “ROP” ≤ 32 with ROP). We measured the axial positions and curvatures of the cornea, anterior and posterior lens, and inner retinal surface. We fit anterior chamber depth (ACD), posterior segment depth (PSD), axial length (AL), and corneal and lenticular curvatures with logistic growth curves that we then evaluated for significant differences. We also measured the length of rays from the centroid to the surface of the eye at 5° intervals, and described the length versus age relationship of each ray, Lray(x), using the same logistic growth curve. We determined the rate of ray elongation, Eray(x), from Lray dy/dx. Then, we estimated the scleral growth that accounted for Eray(x), G(x), at every age and position. Results. Relative to Term, development of ACD, PSD, AL, and corneal and lenticular curvatures was delayed in ROP eyes, but not Premature eyes. In Term infants, G(x) was fast and predominantly equatorial; in age-matched ROP eyes, maximal G(x) was offset by approximately 90°. Conclusions. We produced a model of normal eye growth in term-born subjects. Relative to normal, the ROP eye is characterized by delayed, abnormal growth. PMID:26024095

  8. Effectiveness of Autologous Serum Eye Drops Combined With Punctal Plugs for the Treatment of Sjögren Syndrome-Related Dry Eye.

    PubMed

    Liu, Ying; Hirayama, Masatoshi; Cui, Xin; Connell, Samuel; Kawakita, Tetsuya; Tsubota, Kazuo

    2015-10-01

    To evaluate the efficacy and safety of autologous serum (AS) eye drops combined with punctal plugs (PPs) in patients with Sjögren syndrome (SS)-related dry eye. A retrospective clinical study was performed in patients with dry eye caused by SS. We evaluated the Schirmer test value, tear breakup time (tBUT), and fluorescein and Rose Bengal (RB) staining scores at baseline, 3 months, 6 months, 1 year, and >1 year after treatment. The dry eye indexes were also evaluated in 2 subgroups, which determined by the using of PPs, including the AS + PP group and AS only group. A total of 56 eyes of 28 patients were investigated with a mean follow-up of 42.3 ± 26.1 months. After the application of AS eye drops, the Schirmer test showed no significant changes. The tBUT (2.7 ± 1.9 seconds) was significantly improved at each time point (3.9 ± 3.1, 4.5 ± 3.1, 3.7 ± 2.5, and 5.1 ± 4.0; P < 0.01), fluorescein staining (4.3 ± 2.8) was significantly improved at each time point (2.2 ± 2.2, 1.9 ± 1.9, 1.8 ± 1.6, and 1.8 ± 1.8; P < 0.01), and RB (2.6 ± 3.0) staining was significantly improved from 6-month treatment (1.5 ± 1.9, 1.9 ± 1.9, and 1.4 ± 1.8; P < 0.05, 0.01, and 0.01, respectively). When combined with PPs, the tBUT and RB staining scores were found to be significantly improved in the AS + PP group compared with those of the AS only group. Long-term application of AS eye drops was found to be an effective and apparently safe treatment for SS dry eye. Furthermore, PPs in combination with AS eye drops were considered to have an additive effect on SS dry eye.

  9. Effect of topical 3% diquafosol sodium on eyes with dry eye disease and meibomian gland dysfunction.

    PubMed

    Amano, Shiro; Inoue, Kenji

    2017-01-01

    To prospectively evaluate the effect of topical diquafosol sodium on eyes with dry eye disease (DED) and meibomian gland dysfunction (MGD). The subjects were consecutive patients diagnosed with both DED and MGD at Inouye Eye Hospital between March and September of 2016. The subjects were administered topical 3% diquafosol sodium ophthalmic solution six times a day for 3 months. At each study visit, subjects underwent slit-lamp examination and completed MGD symptoms and dry eye-related quality of life score (DEQS) questionnaires. Meibum quality (meibum score) and meibomian gland loss (meiboscore) were evaluated. Tear lipid layer thickness was measured in both eyes with an ocular surface interferometer immediately after clinic arrival and 20 minutes after instillation of one drop of topical diquafosol. Thirteen patients (3 men, 10 women) with a mean age of 69.5±8.3 years completed the 3-month study. The number of telangiectasia and plugged meibomian gland orifices significantly decreased from baseline after 1 month of diquafosol use. The meibum score and the meiboscore significantly decreased from baseline at 3 months. Also, the lipid layer thickness was greater after diquafosol administration than before administration at baseline and 1, 2, and 3 months by 12.2, 11.5, 9.5, and 17.0 nm, respectively, but this difference was only significant at 3 months ( p =0.039). The DEQS ocular symptom ( p =0.065) and MGD questionnaire ( p =0.081) scores tended to be lower than baseline at 3 months. Diquafosol sodium ophthalmic solution improves DED- and MGD-related signs in eyes with MGD.

  10. Novel method for evaluation of eye movements in patients with narcolepsy.

    PubMed

    Christensen, Julie A E; Kempfner, Lykke; Leonthin, Helle L; Hvidtfelt, Mathias; Nikolic, Miki; Kornum, Birgitte Rahbek; Jennum, Poul

    2017-05-01

    Narcolepsy causes abnormalities in the control of wake-sleep, non-rapid-eye-movement (non-REM) sleep and REM sleep, which includes specific eye movements (EMs). In this study, we aim to evaluate EM characteristics in narcolepsy as compared to controls using an automated detector. We developed a data-driven method to detect EMs during sleep based on two EOG signals recorded as part of a polysomnography (PSG). The method was optimized using the manually scored hypnograms from 36 control subjects. The detector was applied on a clinical sample with subjects suspected for central hypersomnias. Based on PSG, multiple sleep latency test and cerebrospinal fluid hypocretin-1 measures, they were divided into clinical controls (N = 20), narcolepsy type 2 (NT2, N = 19), and narcolepsy type 1 (NT1, N = 28). We investigated the distribution of EMs across sleep stages and cycles. NT1 patients had significantly less EMs during wake, N1, and N2 sleep and more EMs during REM sleep compared to clinical controls, and significantly less EMs during wake and N1 sleep compared to NT2 patients. Furthermore, NT1 patients showed less EMs during NREM sleep in the first sleep cycle and more EMs during NREM sleep in the second sleep cycle compared to clinical controls and NT2 patients. NT1 patients show an altered distribution of EMs across sleep stages and cycles compared to NT2 patients and clinical controls, suggesting that EMs are directly or indirectly controlled by the hypocretinergic system. A data-driven EM detector may contribute to the evaluation of narcolepsy and other disorders involving the control of EMs. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Pediatric Eye Screening Instrumentation

    NASA Astrophysics Data System (ADS)

    Chen, Ying-Ling; Lewis, J. W. L.

    2001-11-01

    Computational evaluations are presented for binocular eye screening using the off-axis digital retinascope. The retinascope, such as the iScreen digital screening system, has been employed to perform pediatric binocular screening using a flash lamp and single-shot camera recording. The digital images are transferred electronically to a reading center for analysis. The method has been shown to detect refractive error, amblyopia, anisocoria, and ptosis. This computational work improves the performance of the system and forms the basis for automated data analysis. For this purpose, variouis published eye models are evaluated with simulated retinascope images. Two to ten million rays are traced in each image calculation. The poster will present the simulation results for a range of eye conditions of refractive error of -20 to +20 diopters with 0.5- to-1 diopter resolution, pupil size of 3 to 8 mm diameter (1-mm increment), and staring angle of 2 to 12 degree (2-degree increment). The variation of the results with the system conditions such as the off-axis distance of light source and the shutter size of camera are also evaluated. The quantitative analysis for each eye’s and system’s condition is then performed to obtain parameters for automatic reading. The summary of the system performance is given and performance-enhancement design modifications are presented.

  12. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    PubMed

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P < .001; gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P < .001; McNemar test). Of the 51 eyes with a closed ACA on gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  13. Evaluation of the Safety and Tolerability of Conjunctival Ring for Posterior Segment of the Eye.

    PubMed

    Kinoshita, Satoshi; Ohguchi, Takeshi; Noda, Kousuke; Murata, Miyuki; Yasueda, Shin-Ichi; Obata, Haruka; Matsunaga, Toru; Fukushima, Tsutomu; Kanda, Atsuhiro; Ishida, Susumu

    2017-08-01

    To evaluate the safety and tolerability of conjunctival rings (CRs), a novel device for drug delivery to the posterior segment of the eye. In animal studies, CRs containing 5% dexamethasone sodium phosphate (DSP) or vehicle solution were placed on the right and left eyes of C57BL/6J mice, respectively. Contact lenses (CLs) containing vehicle solution were used as a control. Twenty-four hours after placement of the CRs, corneal fluorescein staining was graded based on the McDonald-Shadduck scoring system, ranging from 0 to 4. In humans, CRs containing vehicle solution were placed on the right eye of healthy volunteers for 9 hours. The corneal curvature, corneal thickness, intraocular pressure, visual acuity, tear production (Schirmer I test), tear film break-up time and fluorescein staining scores of the cornea (scores ranging from 0 to 3) and conjunctiva (scores ranging from 0 to 6) were assessed before and after wearing the CRs. The release characteristics of DSP from CRs were also evaluated. In animal experiments, corneal fluorescein staining scores were 1 or less in all the groups, and there was no significant difference between the CR group and the CL group. In the preclinical safety evaluation of CR for humans, ophthalmic examination revealed that CR caused no significant changes in all the parameters investigated including corneal curvature (p = 0.77), corneal thickness (p = 0.96), intraocular pressure (p = 0.59), visual acuity (p = 0.14), Schirmer I test results (p = 0.76), tear film break-up time (p = 0.68), corneal fluorescein staining scores (p = 0.64), and conjunctival fluorescein staining scores (p = 0.52). The DSP release from CRs occurs within a few hours, which is similar to the drug-release property of medicated CL, as reported previously. The current data showed the safety and tolerability of CR as a drug delivery device for the treatment of posterior segment diseases.

  14. Retinal Capillary Network and Foveal Avascular Zone in Eyes with Vein Occlusion and Fellow Eyes Analyzed With Optical Coherence Tomography Angiography.

    PubMed

    Adhi, Mehreen; Filho, Marco A Bonini; Louzada, Ricardo N; Kuehlewein, Laura; de Carlo, Talisa E; Baumal, Caroline R; Witkin, Andre J; Sadda, Srinivas R; Sarraf, David; Reichel, Elias; Duker, Jay S; Waheed, Nadia K

    2016-07-01

    To evaluate the perifoveolar retinal capillary network at different depths and to quantify the foveal avascular zone (FAZ) in eyes with retinal vein occlusion (RVO) compared with their fellow eyes and healthy controls using spectral-domain optical coherence tomography angiography (SD-OCTA). We prospectively recruited 23 patients with RVO including 15 eyes with central RVO (CRVO) and 8 eyes with branch RVO (BRVO), their fellow eyes, and 8 age-matched healthy controls (8 eyes) for imaging on prototype OCTA software within RTVue-XR Avanti. The 3 × 3 mm and 6 × 6 mm en face angiograms of superficial and deep retinal capillary plexuses were segmented. Perifoveolar retinal capillary network was analyzed and FAZ was quantified. Decrease in vascular perfusion at the deep plexus was observed in all eyes with CRVO (8/8, 100%) and BRVO (6/6, 100%) without cystoid macular edema, and in 8 of 15 (53%) and 2 of 8 (25%) of the fellow eyes, respectively. Vascular tortuosity was observed in 13 of 15 (87%) CRVO and 5 of 8 (63%) BRVO eyes. Collaterals were seen in 10 of 15 (67%) CRVO and 5 of 8 (63%) BRVO eyes. Mean FAZ area was larger in eyes with RVO than their fellow eyes (1.13 ± 0.25 mm2 versus 0.58 ± 0.28 mm2; P = 0.007) and controls (1.13 ± 0.25 mm2 versus 0.30 ± 0.09 mm2; P < 0.0001), and in fellow eyes of RVO patients when compared to controls (0.58 ± 0.28 mm2 versus 0.30 ± 0.09 mm2; P = 0.01). Spectral-domain OCTA reveals abnormalities at different levels of perifoveolar retinal capillary network and is able to quantify the FAZ in RVO. Longitudinal studies may be considered to evaluate the clinical utility of OCTA in RVO and other retinal vascular diseases.

  15. Transcutaneous periorbital electrical stimulation in the treatment of dry eye.

    PubMed

    Pedrotti, Emilio; Bosello, Francesca; Fasolo, Adriano; Frigo, Anna C; Marchesoni, Ivan; Ruggeri, Alfredo; Marchini, Giorgio

    2017-06-01

    To evaluate efficacy and safety of transcutaneous application of electrical current on symptoms and clinical signs of dry eye (DE). 27 patients with DE underwent transcutaneous electrostimulation with electrodes placed onto the periorbital region of both eyes and manual stimulation with a hand-piece conductor moved by the operator. Each patient underwent 12 sessions of 22 min spread over 2 months, two sessions per week in the first month and one session per week in the second month. Ocular Surface Disease Index (OSDI) questionnaire, tear break-up time (TBUT), fluorescein staining of the cornea, Schirmer I test and adverse events were evaluated at baseline, at end of treatment and at 6 and 12 months. OSDI improved from 43.0±19.2 at baseline to 25.3±22.1 at end of treatment (mean±SD, p=0.001). These effects were substantially maintained at 6-month and 12-month follow-up evaluations. Improvement of the values of TBUT was recorded for the right eye at the end of treatment (p=0.003) and found in the left eye after 12 months (p=0.02). The Oxford scores changed in both eyes at the end of treatment and at the 6-month evaluation (p<0.001), and in the right eye at the 12-month evaluation (p=0.035). Schirmer I improved significantly at the end of treatment in the left eye (p=0.001) and in both eyes at the 12-month evaluation (p=0.004 and p=0.039 for the left and right eye, respectively). A significant reduction of the use of tear substitutes was found at the end of treatment (p=0.003), and was maintained during the follow-up (p<0.001).No complications occurred and patients found the treatment satisfying. Transcutaneous electrical stimulation was shown to improve DE, both subjectively and objectively, without any adverse effects and has the potential to enlarge the armamentarium for treating DE. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. A novel nanoscale-dispersed eye ointment for the treatment of dry eye disease

    NASA Astrophysics Data System (ADS)

    Zhang, Wenjian; Wang, Yan; Lee, Benjamin Tak Kwong; Liu, Chang; Wei, Gang; Lu, Weiyue

    2014-03-01

    A novel nanoscale-dispersed eye ointment (NDEO) for the treatment of severe evaporative dry eye has been successfully developed. The excipients used as semisolid lipids were petrolatum and lanolin, as used in conventional eye ointment, which were coupled with medium-chain triglycerides (MCT) as a liquid lipid; both phases were then dispersed in polyvinyl pyrrolidone solution to form a nanodispersion. Single-factor experiments were conducted to optimize the formulations. A transmission electron micrograph showed that the ointment matrix was entrapped in the nanoemulsion of MCT, with a mean particle size of about 100 nm. The optimized formulation of NDEO was stable when stored for six months at 4 °C, and demonstrated no cytotoxicity to human corneal epithelial cells when compared with commercial polymer-based artificial tears (Tears Natural® Forte). The therapeutic effects of NDEO were evaluated on a mouse model with ‘dry eye’. Both the tear break-up time and fluorescein staining demonstrated therapeutic improvement, displaying a trend of positive correlation with higher concentrations of ointment matrix in the NDEO formulations compared to a marketed product. Histological evaluation demonstrated that the NDEO restored the normal corneal and conjunctival morphology and is safe for ophthalmic application.

  17. An eye on reactor and computer control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schryver, J.; Knee, B.

    1992-01-01

    At ORNL computer software has been developed to make possible an improved eye-gaze measurement technology. Such an inovation could be the basis for advanced eye-gaze systems that may have applications in reactor control, software development, cognitive engineering, evaluation of displays, prediction of mental workloads, and military target recognition.

  18. Safety and efficacy of autologous serum eye drop for treatment of dry eyes in graft-versus-host disease.

    PubMed

    Azari, Amir A; Karadag, Remzi; Kanavi, Mozhgan Rezaei; Nehls, Sarah; Barney, Neal; Kim, Kyungmann; Longo, Walter; Hematti, Peiman; Juckett, Mark

    2017-06-01

    To evaluate the treatment of autologous serum eye drops (ASED) on dry eyes in patients with graft-versus-host disease (GVHD). A retrospective chart review of 35 patients with a history of ocular GVHD following hematopoietic stem cell transplantation that used ASED to alleviate dry eye symptoms was performed. Patients were categorized into three different groups. If patients had available ophthalmic data before and after starting treatment was group 1 (n = 14), had available ophthalmic data after starting treatment in group 2 (n = 10) and had available ophthalmic data before treatment or did not have any data after starting treatment in group 3 (n = 11). Data were collected on patient's age, gender, primary diagnosis, visual acuity and fluorescein corneal staining were collected on individual eyes in order to evaluate the efficacy of the ASED on alleviating dry eye-related signs and symptoms. No adverse ocular effect from the ASED was found in our series (except one fungal keratitis). All patients reported either improvement (55%) or stability (45%) in their ocular symptoms upon the use of ASED. In patients with available data before and after starting treatment, the corneal staining score improved by a median of 1 (p = 0.003) and the LogMAR visual acuity had a non-significant improvement. In our study, ASED used by patients with ocular GVHD were both safe and effective. ASED should be considered in patients with GVHD who suffer from dry eyes.

  19. Cosmetics Europe compilation of historical serious eye damage/eye irritation in vivo data analysed by drivers of classification to support the selection of chemicals for development and evaluation of alternative methods/strategies: the Draize eye test Reference Database (DRD).

    PubMed

    Barroso, João; Pfannenbecker, Uwe; Adriaens, Els; Alépée, Nathalie; Cluzel, Magalie; De Smedt, Ann; Hibatallah, Jalila; Klaric, Martina; Mewes, Karsten R; Millet, Marion; Templier, Marie; McNamee, Pauline

    2017-02-01

    A thorough understanding of which of the effects assessed in the in vivo Draize eye test are responsible for driving UN GHS/EU CLP classification is critical for an adequate selection of chemicals to be used in the development and/or evaluation of alternative methods/strategies and for properly assessing their predictive capacity and limitations. For this reason, Cosmetics Europe has compiled a database of Draize data (Draize eye test Reference Database, DRD) from external lists that were created to support past validation activities. This database contains 681 independent in vivo studies on 634 individual chemicals representing a wide range of chemical classes. A description of all the ocular effects observed in vivo, i.e. degree of severity and persistence of corneal opacity (CO), iritis, and/or conjunctiva effects, was added for each individual study in the database, and the studies were categorised according to their UN GHS/EU CLP classification and the main effect driving the classification. An evaluation of the various in vivo drivers of classification compiled in the database was performed to establish which of these are most important from a regulatory point of view. These analyses established that the most important drivers for Cat 1 Classification are (1) CO mean ≥ 3 (days 1-3) (severity) and (2) CO persistence on day 21 in the absence of severity, and those for Cat 2 classification are (3) CO mean ≥ 1 and (4) conjunctival redness mean ≥ 2. Moreover, it is shown that all classifiable effects (including persistence and CO = 4) should be present in ≥60 % of the animals to drive a classification. As a consequence, our analyses suggest the need for a critical revision of the UN GHS/EU CLP decision criteria for the Cat 1 classification of chemicals. Finally, a number of key criteria are identified that should be taken into consideration when selecting reference chemicals for the development, evaluation and/or validation of alternative methods and

  20. Effect of lipid-based dry eye supplements on the tear film in wearers of eye cosmetics.

    PubMed

    Wang, Michael T M; Cho, Irene Sung Hee; Jung, Soo Hee; Craig, Jennifer P

    2017-08-01

    To compare the effects on tear film parameters and contamination in cosmetic eyeliner wearers, after single application of two lipid-based dry eye treatments: a lipid-containing lubricant eye drop and a phospholipid liposomal spray. Fifty participants were enrolled in a prospective, randomised, paired-eye, investigator-masked trial. Pencil eyeliner (Body Shop ® Crayon Eye Definer) was applied to the upper eyelid periocular skin of both eyes, anterior to the lash line. Baseline tear film quality was assessed fifteen minutes after eyeliner application. A lubricant drop (Systane ® Balance) was then applied to one eye (randomised), and liposomal spray (Tears Again ® ) to the contralateral eye. Tear film contamination, lipid layer grade, non-invasive tear film break-up time and tear evaporation rate were evaluated fifteen minutes post-treatment and compared to pre-treatment values. Pre-treatment measurements did not differ between eyes assigned to lubricant drop and liposomal spray. Tear film contamination was observed in a greater proportion of eyes following both treatments (both p<0.05), with no significant difference between treatments (p=0.41). Both treatments improved lipid layer thickness (both p≤0.01), but effected no significant change in non-invasive tear film break-up time or tear evaporation rate (all p>0.05). Changes in tear film parameters did not differ between treatments (all p>0.05). Both the lipid-containing lubricant eye drop and phospholipid liposomal spray result in clinically apparent tear film contamination in eyeliner cosmetic wearers. Although both treatments effected an increase in lipid layer thickness, neither displayed clinical efficacy in improving tear film stability. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. The isolated chicken eye test as a suitable in vitro method for determining the eye irritation potential of household cleaning products.

    PubMed

    Schutte, K; Prinsen, M K; McNamee, P M; Roggeband, R

    2009-08-01

    Eye irritation is an important endpoint in the safety evaluation of consumer products and their ingredients. Several in vitro methods have been developed and are used by different industry sectors to assess eye irritation. One such in vitro method in use for some time already is the isolated chicken eye test (ICE). This investigation focuses on assessing the ICE as a method to determine the eye irritation potential of household cleaning products, both for product safety assurance prior to marketing and for classification and labeling decisions. The ICE involves a single application of test substances onto the cornea of isolated chicken eyes. Endpoints are corneal swelling, corneal opacity and fluorescein retention. The ICE results were compared to historic LVET data in this study due to availability of such in vivo data and the ability to correlate LVET to human experience data on the outcome of accidental exposures to household cleaning products in general. The results of this study indicate that the ICE test is a useful in vitro method for evaluating the eye irritation/corrosion potential and establishing classification and labeling for household cleaning products. For new product formulations, it is best used as part of a weight-of-evidence approach and benchmarked against data from comparable formulations with known eye irritation/corrosion profiles and market experience.

  2. Correlation between corneal innervation and inflammation evaluated with confocal microscopy and symptomatology in patients with dry eye syndromes: a preliminary study.

    PubMed

    Tepelus, Tudor C; Chiu, Gloria B; Huang, Jianyan; Huang, Ping; Sadda, SriniVas R; Irvine, John; Lee, Olivia L

    2017-09-01

    To evaluate corneal innervation and inflammatory cell infiltration using in vivo confocal microscopy (IVCM) and to correlate these findings with subjective symptoms of dry eye, as measured by the Ocular Surface Disease Index (OSDI) in patients with non-Sjögren's (NSDE) and Sjögren's syndrome dry eyes (SSDE). Central corneal images were prospectively captured from 10 age-matched healthy control eyes, 24 eyes with clinically diagnosed NSDE and 44 eyes with clinically diagnosed SSDE, using IVCM (HRT III RCM). Density, tortuosity and reflectivity of corneal nerves, presence of inflammatory dendritic cells (DCs) and OSDI scores were evaluated. Images obtained by IVCM from 78 eyes were analyzed. The density of nerve fibers was 1562 ± 996 μm/frame in the SSDE group, 2150 ± 1015 μm/frame in the NSDE group and 2725 ± 687 μm/frame in the control group (P < 0.05, ANOVA). In comparison to the control group, the density of nerve fibers was decreased in the SSDE (P < 0.001) and the NSDE groups (P = 0.06), with increased nerve tortuosity and decreased reflectivity in both groups (both P < 0.05). The density of DCs was 71.65 ± 72.54 cells/mm 2 in the SSDE group, 40.33 ± 31.63 cells/mm 2 in the NSDE group and 27.53 ± 5.58 cells/mm 2 in the control group (P < 0.05, ANOVA). In comparison to the control group, the density of DCs was increased in the SSDE (P < 0.001) and the NSDE groups (P = 0.07). Significant correlations were found between the nerve density and DC density (r = -0.57, P < 0.001), between the nerve density and OSDI scores (r = -0.91, P < 0.001) and between the nerve reflectivity and OSDI scores (r = -0.75, P < 0.001). The corneas of eyes affected with NSDE and SSDE are characterized by alterations in corneal innervation and infiltration of inflammatory DCs. Corneal nerve density and reflectivity are correlated with severity of subjective dry eye symptoms, as measured by OSDI score.

  3. New screening methods for donor eye-bank eyes.

    PubMed

    Terry, M A; Ousley, P J

    1999-07-01

    Current methods of screening donor eyes for corneal transplantation are not always effective in excluding corneas with abnormal topography. We used the Orbscan to determine whether corneal-thickness maps could be used as a technique for donor tissue screening. Forty eye-bank eyes were measured with the Orbscan, and a corneal-thickness map was generated. Average central pachymetry measurements from each map were compared with the thinnest midperipheral thickness reading. Two eyes from a donor who had photorefractive keratectomy (PRK) and two eyes from a donor with keratoconus were then compared with the normal donor eye results. The average difference between the thinnest midperipheral pachymetry and the central pachymetry in the control group was 0.040 +/- 0.026 mm. The eyes from the donor with PRK showed larger disparities between the central and midperipheral thicknesses because of the thinned central cornea, with differences of 0.154 mm in the right eye and 0.106 mm in the left eye. The eyes from the donor with keratoconus had midperipheral corneas that were thinner than the center, indicating eccentric, ectatic cones. The differences in thickness between the center and midperiphery in the eyes from the donor with PRK and the donor with keratoconus differed from the control group by >2 SD. Diseases or surgery that affect the relationship between the central and midperipheral corneal thickness may be screened through Orbscan pachymetry mapping with comparison with a normal range.

  4. Peripheral refraction with eye and head rotation with contact lenses.

    PubMed

    Lopes-Ferreira, Daniela P; Neves, Helena I F; Faria-Ribeiro, Miguel; Queirós, António; Fernandes, Paulo R B; González-Méijome, José M

    2015-04-01

    To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Nineteen right eyes from 19 myopic patients (average central M ± SD = -2.67 ± 1.66 D) aged 20-27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D(®)) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. For the naked eye, refractive pattern (M, J0 and J45) across the central 60° of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Survey of Ophthalmologists Regarding Practice Patterns for Dry Eye and Sjogren Syndrome.

    PubMed

    Bunya, Vatinee Y; Fernandez, Karen B; Ying, Gui-Shuang; Massaro-Giordano, Mina; Macchi, Ilaria; Sulewski, Michael E; Hammersmith, Kristin M; Nagra, Parveen K; Rapuano, Christopher J; Orlin, Stephen E

    2018-01-15

    To survey ophthalmologists about current practice patterns regarding the evaluation of dry eye patients and referrals for a Sjogren syndrome (SS) workup. An online survey was sent to ophthalmologists affiliated with the Scheie Eye Institute or Wills Eye Hospital using REDCap in August 2015. Descriptive statistics were used to summarize the data. Four hundred seventy-four survey invitations were sent out and 101 (21%) ophthalmologists completed the survey. The common traditional dry eye test performed was corneal fluorescein staining (62%) and the most common newer dry eye test performed was tear osmolarity (18%). Half of respondents (51%) refer fewer than 5% of their dry eye patients for SS workups, with 18% reporting that they never refer any patients. The most common reasons for referrals included positive review of systems (60%), severe dry eye symptoms (51%) or ocular signs (47%), or dry eye that is refractory to treatment (42%). The majority (83%) felt that there is a need for an evidence-based standardized screening tool for dry eye patients to decide who should be referred for evaluation for SS. Ophthalmologists continue to prefer the use of traditional dry eye tests in practice, with the most common test being corneal fluorescein staining. There is an underreferral of dry eye patients for SS workups, which is contributing to the continued underdiagnosis of the disease. Most respondents felt that there was a need for an evidence-based standardized screening tool to decide which dry eye patients should be referred for SS evaluations.

  6. Retrospective analysis of the Draize test for serious eye damage/eye irritation: importance of understanding the in vivo endpoints under UN GHS/EU CLP for the development and evaluation of in vitro test methods.

    PubMed

    Adriaens, Els; Barroso, João; Eskes, Chantra; Hoffmann, Sebastian; McNamee, Pauline; Alépée, Nathalie; Bessou-Touya, Sandrine; De Smedt, Ann; De Wever, Bart; Pfannenbecker, Uwe; Tailhardat, Magalie; Zuang, Valérie

    2014-03-01

    For more than two decades, scientists have been trying to replace the regulatory in vivo Draize eye test by in vitro methods, but so far only partial replacement has been achieved. In order to better understand the reasons for this, historical in vivo rabbit data were analysed in detail and resampled with the purpose of (1) revealing which of the in vivo endpoints are most important in driving United Nations Globally Harmonized System/European Union Regulation on Classification, Labelling and Packaging (UN GHS/EU CLP) classification for serious eye damage/eye irritation and (2) evaluating the method's within-test variability for proposing acceptable and justifiable target values of sensitivity and specificity for alternative methods and their combinations in testing strategies. Among the Cat 1 chemicals evaluated, 36-65 % (depending on the database) were classified based only on persistence of effects, with the remaining being classified mostly based on severe corneal effects. Iritis was found to rarely drive the classification (<4 % of both Cat 1 and Cat 2 chemicals). The two most important endpoints driving Cat 2 classification are conjunctiva redness (75-81 %) and corneal opacity (54-75 %). The resampling analyses demonstrated an overall probability of at least 11 % that chemicals classified as Cat 1 by the Draize eye test could be equally identified as Cat 2 and of about 12 % for Cat 2 chemicals to be equally identified as No Cat. On the other hand, the over-classification error for No Cat and Cat 2 was negligible (<1 %), which strongly suggests a high over-predictive power of the Draize eye test. Moreover, our analyses of the classification drivers suggest a critical revision of the UN GHS/EU CLP decision criteria for the classification of chemicals based on Draize eye test data, in particular Cat 1 based only on persistence of conjunctiva effects or corneal opacity scores of 4. In order to successfully replace the regulatory in vivo Draize eye test, it will

  7. 75 FR 20853 - National Eye Institute; Notice of Closed Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES National Institutes of Health National Eye Institute... unwarranted invasion of personal privacy. Name of Committee: National Eye Institute Special Emphasis Panel, Immunosuppression for Eye Diseases. Date: April 20, 2010. Time: 3 p.m. to 4 p.m. Agenda: To review and evaluate...

  8. Clinical evaluation of the additive effect of diquafosol tetrasodium on sodium hyaluronate monotherapy in patients with dry eye syndrome: a prospective, randomized, multicenter study.

    PubMed

    Kamiya, K; Nakanishi, M; Ishii, R; Kobashi, H; Igarashi, A; Sato, N; Shimizu, K

    2012-10-01

    To assess the additive effect of diquafosol tetrasodium on sodium hyaluronate monotherapy in patients with dry eye syndrome. This study evaluated 64 eyes of 32 patients (age: 62.6±12.8 years (mean±SD)) in whom treatment with 0.1% sodium hyaluronate was insufficiently responsive. The eyes were randomly assigned to one of the two regimens in each patient: topical administration of sodium hyaluronate and diquafosol tetrasodium in one eye, and that of sodium hyaluronate in the other. Before treatment, and 2 and 4 weeks after treatment, we determined tear volume, tear film break-up time (BUT), fluorescein and rose bengal vital staining scores, subjective symptoms, and adverse events. We found a significant improvement in BUT (P=0.049, Dunnett test), fluorescein and rose bengal staining scores (P=0.02), and in subjective symptoms (P=0.004 for dry eye sensation, P=0.02 for pain, and P=0.02 for foreign body sensation) 4 weeks after treatment in the diquafosol eyes. On the other hand, we found no significant change in these parameters after treatment in the control eyes. In dry eyes, where sodium hyaluronate monotherapy was insufficient, diquafosol tetrasodium was effective in improving objective and subjective symptoms, suggesting its viability as an option for the additive treatment of such eyes.

  9. Autologous serum eye drops for dry eye

    PubMed Central

    Pan, Qing; Angelina, Adla; Zambrano, Andrea; Marrone, Michael; Stark, Walter J; Heflin, Thomas; Tang, Li; Akpek, Esen K

    2014-01-01

    Background Theoretically, autologous serum eye drops (AS) have a potential advantage over traditional therapies based on the assumption that AS serve not only as a lacrimal substitute to provide lubrication, but also contain other biochemical components mimicking natural tears more closely. The application of AS in dry eye treatment has gained popularity as a second-line therapy in the treatment of dry eye. Published studies on the subject indicate that autologous serum could be an effective treatment for dry eye. Objectives To evaluate the efficacy and safety of AS compared to artificial tears for treating dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 3), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLD MEDLINE, (January 1950 to April 2013), EMBASE (January 1980 to April 2013), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to April 2013), the meta Register of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (September 2013) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 15 April 2013. Selection criteria We included randomized controlled trials (RCTs) in which AS was compared to artificial tears in the treatment of dry eye in adults. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text articles of potentially eligible trials. Two review authors extracted data and assessed the methodological quality and characteristics of the included trials.We contacted investigators for missing data

  10. Eye pain

    MedlinePlus

    Ophthalmalgia; Pain - eye ... Pain in the eye can be an important symptom of a health problem. Make sure you tell your health care provider if you have eye pain that does not go away. Tired eyes or ...

  11. Eye movement abnormalities in hermansky-pudlak syndrome.

    PubMed

    Gradstein, Libe; FitzGibbon, Edmond J; Tsilou, Ekaterini T; Rubin, Benjamin I; Huizing, Marjan; Gahl, William A

    2005-08-01

    Hermansky-Pudlak Syndrome (HPS) is a type of oculocutaneous albinism associated with a bleeding diathesis and pulmonary fibrosis. Although it is known that patients with HPS exhibit nystagmus, the nature of these abnormal eye movements has not been studied. Twenty-seven patients with HPS, diagnosed by platelet morphology and genetic analysis, underwent a systemic evaluation and complete eye examination. Twenty-five had eye movement recordings using magnetic search coil, infrared, or video oculography. All patients had iris transillumination, foveal hypoplasia, and variable hypopigmentation in skin and eyes. All had bleeding tendencies, and 2 reported excessive bleeding during strabismus surgery. Nine patients had pulmonary fibrosis. Visual acuities ranged from 20/20- to 20/320. Twenty patients had strabismus despite 6 having strabismus surgery previously. Ocular oscillations consistent with congenital nystagmus (CN) were clinically evident in 24 of 27 patients, and half showed periodic alternating nystagmus. In 3 patients without CN, eye movement recordings revealed minimal end-gaze nystagmus, square-wave jerks, drift during fixation and saccades, and low-gain pursuit. These patients had melanin in the posterior pole and better visual acuities than the others (P = 0.002). Most patients with HPS have CN, and many have periodic alternating nystagmus. Some have subtle eye movement abnormalities without clinically evident nystagmus, which can obscure the diagnosis, especially if hypopigmentation is mild. Absence of clinical nystagmus in a child with HPS suggests good vision. Patients with albinism, especially before surgery, should be evaluated for HPS to prevent life-threatening complications.

  12. Ethical and Pedagogical Issues in the Use of Simulation Activities in the Classroom: Evaluating the "Blue Eyes-Brown Eyes" Prejudice Simulation.

    ERIC Educational Resources Information Center

    Byrnes, Deborah A.; Kiger, Gary

    The effectiveness of a well-known prejudice-reduction simulation activity, "Blue Eyes-Brown Eyes," was assessed as a tool for changing the attitudes of nonblack teacher education students toward blacks. The subjects were 164 students enrolled in eight sections of an introductory elementary education course at a state university. Three…

  13. Evaluation of an eye-pointer interaction device for human-computer interaction.

    PubMed

    Cáceres, Enrique; Carrasco, Miguel; Ríos, Sebastián

    2018-03-01

    Advances in eye-tracking technology have led to better human-computer interaction, and involve controlling a computer without any kind of physical contact. This research describes the transformation of a commercial eye-tracker for use as an alternative peripheral device in human-computer interactions, implementing a pointer that only needs the eye movements of a user facing a computer screen, thus replacing the need to control the software by hand movements. The experiment was performed with 30 test individuals who used the prototype with a set of educational videogames. The results show that, although most of the test subjects would prefer a mouse to control the pointer, the prototype tested has an empirical precision similar to that of the mouse, either when trying to control its movements or when attempting to click on a point of the screen.

  14. Eye Movement Dysfunction in First-Degree Relatives of Patients with Schizophrenia: A Meta-Analytic Evaluation of Candidate Endophenotypes

    ERIC Educational Resources Information Center

    Calkins, Monica E.; Iacono, William G.; Ones, Deniz S.

    2008-01-01

    Several forms of eye movement dysfunction (EMD) are regarded as promising candidate endophenotypes of schizophrenia. Discrepancies in individual study results have led to inconsistent conclusions regarding particular aspects of EMD in relatives of schizophrenia patients. To quantitatively evaluate and compare the candidacy of smooth pursuit,…

  15. Complications related to a cosmetic eye-whitening procedure.

    PubMed

    Vo, Rosalind C; Stafeeva, Ksenia; Aldave, Anthony J; Stulting, R Doyle; Moore, Quianta; Pflugfelder, Stephen C; Chungfat, Neil C; Holsclaw, Douglas S; Margolis, Todd P; Deng, Sophie X

    2014-11-01

    To report sight-threatening complications following extensive bulbar conjunctival resection and postoperative mitomycin C therapy for cosmetic eye-whitening in the United States. Retrospective noncomparative case series. Multicenter report of 9 patients referred for evaluation and management of complications following bilateral cosmetic eye whitening. Seventeen eyes of 9 patients underwent cosmetic eye-whitening performed between 2 and 48 months prior to referral to one of the centers. Sixteen of the 17 eyes had persistent conjunctival epithelial defects, with 10 eyes requiring amniotic membrane grafting to facilitate re-epithelialization. Four eyes of 2 patients developed limbal stem cell compromise confirmed with in vivo confocal laser scanning microscopy. One patient developed infectious scleritis and diplopia resulting from Tenon capsule scarring. Another patient developed scleral necrosis, secondary infectious scleritis, and infectious endophthalmitis. This patient subsequently developed noninfectious scleritis that required 3-drug-regimen immunosuppression. Severe adverse effects can occur after extensive cosmetic conjunctival resection followed by topical mitomycin C application. Patients and physicians should be aware of the potential sight-threatening complications associated with this eye-whitening procedure. Published by Elsevier Inc.

  16. Demonstration of angle widening using EyeCam after laser peripheral iridotomy in eyes with angle closure.

    PubMed

    Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2010-06-01

    To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.

  17. Human amygdala activation during rapid eye movements of rapid eye movement sleep: an intracranial study.

    PubMed

    Corsi-Cabrera, María; Velasco, Francisco; Del Río-Portilla, Yolanda; Armony, Jorge L; Trejo-Martínez, David; Guevara, Miguel A; Velasco, Ana L

    2016-10-01

    The amygdaloid complex plays a crucial role in processing emotional signals and in the formation of emotional memories. Neuroimaging studies have shown human amygdala activation during rapid eye movement sleep (REM). Stereotactically implanted electrodes for presurgical evaluation in epileptic patients provide a unique opportunity to directly record amygdala activity. The present study analysed amygdala activity associated with REM sleep eye movements on the millisecond scale. We propose that phasic activation associated with rapid eye movements may provide the amygdala with endogenous excitation during REM sleep. Standard polysomnography and stereo-electroencephalograph (SEEG) were recorded simultaneously during spontaneous sleep in the left amygdala of four patients. Time-frequency analysis and absolute power of gamma activity were obtained for 250 ms time windows preceding and following eye movement onset in REM sleep, and in spontaneous waking eye movements in the dark. Absolute power of the 44-48 Hz band increased significantly during the 250 ms time window after REM sleep rapid eye movements onset, but not during waking eye movements. Transient activation of the amygdala provides physiological support for the proposed participation of the amygdala in emotional expression, in the emotional content of dreams and for the reactivation and consolidation of emotional memories during REM sleep, as well as for next-day emotional regulation, and its possible role in the bidirectional interaction between REM sleep and such sleep disorders as nightmares, anxiety and post-traumatic sleep disorder. These results provide unique, direct evidence of increased activation of the human amygdala time-locked to REM sleep rapid eye movements. © 2016 European Sleep Research Society.

  18. Evaluation of retinal nerve fiber layer thickness in the area of apparently normal hemifield in glaucomatous eyes with optical coherence tomography.

    PubMed

    Kee, Changwon; Cho, Changhwan

    2003-06-01

    The authors investigated the correlation between visual field defects detected by automated perimetry and the thickness of the retinal nerve fiber layer measured with optical coherence tomography, and examined whether there is a decrease in retinal nerve fiber layer thickness in the apparently normal hemifield of glaucomatous eyes. Forty-one patients with glaucoma and 41 normal control subjects were included in this study. Statistical correlations between the sum of the total deviation of 37 stimuli of each hemifield and the ratio of decrease in retinal nerve fiber layer thickness were evaluated. The statistical difference between the retinal nerve fiber layer thickness of the apparently normal hemifield in glaucomatous eyes and that of the corresponding hemifield in normal subjects was also evaluated. There was a statistically significant correlation in the sum of the total deviation and retinal nerve fiber layer thickness decrease ratio (superior hemifield, P = 0.001; inferior hemifield, P = 0.003). There was no significant decrease in retinal nerve fiber layer thickness in the area that corresponded to the normal visual field in the hemifield defect with respect to the horizontal meridian in glaucomatous eyes (superior side, P = 0.148; inferior side, P = 0.341). Optical coherence tomography was capable of demonstrating and measuring retinal nerve fiber layer abnormalities. No changes in the retinal nerve fiber layer thickness of the apparently normal hemifield were observed in glaucomatous eyes.

  19. Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.

    PubMed

    Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio

    2015-01-01

    In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.

  20. Eye Absence Does Not Regulate Planarian Stem Cells during Eye Regeneration.

    PubMed

    LoCascio, Samuel A; Lapan, Sylvain W; Reddien, Peter W

    2017-02-27

    Dividing cells called neoblasts contain pluripotent stem cells and drive planarian flatworm regeneration from diverse injuries. A long-standing question is whether neoblasts directly sense and respond to the identity of missing tissues during regeneration. We used the eye to investigate this question. Surprisingly, eye removal was neither sufficient nor necessary for neoblasts to increase eye progenitor production. Neoblasts normally increase eye progenitor production following decapitation, facilitating regeneration. Eye removal alone, however, did not induce this response. Eye regeneration following eye-specific resection resulted from homeostatic rates of eye progenitor production and less cell death in the regenerating eye. Conversely, large head injuries that left eyes intact increased eye progenitor production. Large injuries also non-specifically increased progenitor production for multiple uninjured tissues. We propose a model for eye regeneration in which eye tissue production by planarian stem cells is not directly regulated by the absence of the eye itself. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Coping with dry eyes: a qualitative approach.

    PubMed

    Yeo, Sharon; Tong, Louis

    2018-01-16

    Dry eye is a common problem that affects many people worldwide, reducing quality of life and impacting daily activities. A qualitative approach often used in medicine and other disciplines is used to evaluate how people with dry eye cope with this impact. Six focus group sessions were conducted at the Singapore National Eye Centre (SNEC), premises of an eye research institute. These focus groups consist of a spectrum of dry eye sufferers (30 women, 8 men, aged 61 ± 11.8 years). Standard methods of coding followed by determination of themes were adhered to. Where classification was difficult, consensus was made between 3 assessors. Audio-recorded transcripts were coded in 10 themes by 3 assessors independently. Four of the themes involved traditional measures such as lid warming, cleansing, lubrication and oral dietary supplements. The other themes discovered were Traditional Chinese Medicine, modification of eye-care habits (e.g. wearing sunglasses), environmental humidity, lifestyle (e.g. sleeping habits), psychological attitude, and lastly sharing and communication. Holistic coping strategies were found to be prominent in dry eye sufferers from these focus groups, and people tend to find personalised ways of coping with the impact of dry eye on daily living.

  2. Evaluation of a Novel Artificial Tear in the Prevention and Treatment of Dry Eye in an Animal Model.

    PubMed

    She, Yujing; Li, Jinyang; Xiao, Bing; Lu, Huihui; Liu, Haixia; Simmons, Peter A; Vehige, Joseph G; Chen, Wei

    2015-11-01

    To evaluate effects of a novel multi-ingredient artificial tear formulation containing carboxymethylcellulose (CMC) and hyaluronic acid (HA) in a murine dry eye model. Dry eye was induced in mice (C57BL/6) using an intelligently controlled environmental system (ICES). CMC+HA (Optive Fusion™), CMC-only (Refresh Tears(®)), and HA-only (Hycosan(®)) artificial tears and control phosphate-buffered saline (PBS) were administered 4 times daily and compared with no treatment (n = 64 eyes per group). During regimen 1 (prevention regimen), mice were administered artificial tears or PBS for 14 days (starting day 0) while they were exposed to ICES, and assessed on days 0 and 14. During regimen 2 (treatment regimen), mice exposed to ICES for 14 days with no intervention were administered artificial tears or PBS for 14 days (starting day 14) while continuing exposure to ICES, and assessed on days 0, 14, and 28. Corneal fluorescein staining and conjunctival goblet cell density were measured. Artificial tear-treated mice had significantly better outcomes than control groups on corneal staining and goblet cell density (P < 0.01). Mice administered CMC+HA also showed significantly lower corneal fluorescein staining and higher goblet cell density, compared with CMC (P < 0.01) and HA (P < 0.05) in both regimens 1 and 2. The artificial tear formulation containing CMC and HA was effective in preventing and treating environmentally induced dry eye. Improvements observed for corneal fluorescein staining and conjunctival goblet cell retention suggest that this combination may be a viable treatment option for dry eye disease.

  3. New Eye Cleansing Product Improves Makeup-Related Ocular Problems.

    PubMed

    Okura, Masako; Kawashima, Motoko; Katagiri, Mikiyuki; Shirasawa, Takuji; Tsubota, Kazuo

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms.

  4. New Eye Cleansing Product Improves Makeup-Related Ocular Problems

    PubMed Central

    Okura, Masako; Kawashima, Motoko

    2015-01-01

    Purpose. This study evaluated the effects of using a newly developed eye cleansing formulation (Eye Shampoo) to cleanse the eyelids for 4 weeks in a parallel-group comparative study in women with chronic eye discomfort caused by heavy use of eye makeup and poor eye hygiene habits. Methods. Twenty women participants who met the inclusion criteria were randomly allocated to 2 groups comprising 10 participants each. The participants were asked to use either artificial tears alone or artificial tears in conjunction with Eye Shampoo for 4 weeks. The participants answered the questionnaire again and were reexamined, and changes in symptoms within each group and variations of symptoms between the two groups were statistically analyzed. Results. In the group using only artificial tears, improvements in subjective symptoms but not in ophthalmologic examination results were found. In the group using Eye Shampoo together with artificial tears, significant improvements were observed in the subjective symptoms, meibomian orifice obstruction, meibum secretion, tear breakup time, and superficial punctate keratopathy. Conclusion. In patients with chronic eye discomfort thought to be caused by heavy eye makeup, maintaining eyelid hygiene using Eye Shampoo caused a marked improvement in meibomian gland blockage and dry eye symptoms. PMID:26347812

  5. FogEye UV Sensor System evaluation : Phase III report.

    DOT National Transportation Integrated Search

    2002-11-01

    FogEye technology offers the potential for operation of electro optical sensors and systems that function "hands-off", over extended distances during varying atmospheric conditions, day and night. The technology has been shown to employ solar blind u...

  6. The application of autologous serum eye drops in severe dry eye patients; subjective and objective parameters before and after treatment.

    PubMed

    Jirsova, Katerina; Brejchova, Kristyna; Krabcova, Ivana; Filipec, Martin; Al Fakih, Aref; Palos, Michalis; Vesela, Viera

    2014-01-01

    To assess the impact of autologous serum (AS) eye drops on the ocular surface of patients with bilateral severe dry eye and to draw a comparison between the clinical and laboratory examinations and the degree of subjective symptoms before and after serum treatment. A three-month prospective study was conducted on 17 patients with severe dry eye. AS eye drops were applied a maximum of 12 times a day together with regular therapy. Dry eye status was evaluated by clinical examination (visual acuity, Schirmer test, tear film breakup time, vital staining, tear film debris and meniscus), conjunctival impression cytology (epithelial and goblet cell density, snake-like chromatin, HLA-DR-positive and apoptotic cells) and subjectively by the patients. The application of AS eye drops led to a significant improvement in the Schirmer test (p < 0.01) and tear film debris (p < 0.05). The densities of goblet (p < 0.0001) and epithelial cells (p < 0.05) were significantly increased, indicating a decrease of squamous metaplasia after AS treatment. A significant decrease (p < 0.05) was found in the number of apoptotic, HLA-DR-positive and snake-like chromatin cells on the ocular surface. A significant improvement was found in all evaluated subjective symptoms. Altogether, the clinical results were improved in 77%, the laboratory results in 75% and the subjective feelings in 63% of the eyes. We found that three-month AS treatment led especially to the improvement of ocular surface dryness and damage of the epithelium. The improvement of dry eye after AS treatment correlated well with the clinical, laboratory and subjective findings. From the patients' subjective point of view, the positive effect of AS decreased with time, but still persisted up to three months after the end of therapy.

  7. Clinical guidelines for management of dry eye associated with Sjögren disease.

    PubMed

    Foulks, Gary N; Forstot, S Lance; Donshik, Peter C; Forstot, Joseph Z; Goldstein, Michael H; Lemp, Michael A; Nelson, J Daniel; Nichols, Kelly K; Pflugfelder, Stephen C; Tanzer, Jason M; Asbell, Penny; Hammitt, Katherine; Jacobs, Deborah S

    2015-04-01

    To provide a consensus clinical guideline for management of dry eye disease associated with Sjögren disease by evaluating published treatments and recommending management options. Consensus panel evaluation of reported treatments for dry eye disease. Using the 2007 Report of the International Workshop on Dry Eye (DEWS) as a starting point, a panel of eye care providers and consultants evaluated peer-reviewed publications and developed recommendations for evaluation and management of dry eye disease associated with Sjögren disease. Publications were graded according to the American Academy of Ophthalmology Preferred Practice Pattern guidelines for level of evidence. Strength of recommendation was according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) guidelines. The recommendations of the panel are briefly summarized herein. Evaluation should include symptoms of both discomfort and visual disturbance as well as determination of the relative contribution of aqueous production deficiency and evaporative loss of tear volume. Objective parameters of tear film stability, tear osmolarity, degree of lid margin disease, and ocular surface damage should be used to stage severity of dry eye disease to assist in selecting appropriate treatment options. Patient education with regard to the nature of the problem, aggravating factors, and goals of treatment is critical to successful management. Tear supplementation and stabilization, control of inflammation of the lacrimal glands and ocular surface, and possible stimulation of tear production are treatment options that are used according to the character and severity of dry eye disease. Management guidelines for dry eye associated with Sjögren's disease are presented. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Cornea and anterior eye assessment with placido-disc keratoscopy, slit scanning evaluation topography and scheimpflug imaging tomography

    PubMed Central

    Martin, Raul

    2018-01-01

    Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice. PMID:29480244

  9. Cornea and anterior eye assessment with placido-disc keratoscopy, slit scanning evaluation topography and scheimpflug imaging tomography.

    PubMed

    Martin, Raul

    2018-03-01

    Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple and several devices and technologies allow to explore and to manage patients. The purpose of this special issue is to present and also to update in the evaluation of cornea and ocular surface and this second part, reviews a description of the corneal topography and tomography techniques, providing updated information of the clinical recommendations of these techniques in eye care practice. Placido-based topographers started an exciting anterior corneal surface analysis that allows the development of current corneal tomographers that provide a full three-dimensional reconstruction of the cornea including elevation, curvature, and pachymetry data of anterior and posterior corneal surfaces. Although, there is not an accepted reference standard technology for corneal topography description and it is not possible to determine which device produces the most accurate topographic measurements, placido-based topographers are a valuable technology to be used in primary eye care and corneal tomograhers expanding the possibilities to explore cornea and anterior eye facilitating diagnosis and follow-up in several situations, raising patient follow-up, and improving the knowledge regarding to the corneal anatomy. Main disadvantages of placido-based topographers include the absence of information about the posterior corneal surface and limited corneal surface coverage without data from the para-central and/or peripheral corneal surface. However, corneal tomographers show repeatable anterior and posterior corneal surfaces measurements, providing full corneal thickness data improving cornea, and anterior surface assessment. However, differences between devices suggest that they are not interchangeable in clinical practice.

  10. Genotoxicity, acute oral and dermal toxicity, eye and dermal irritation and corrosion and skin sensitisation evaluation of silver nanoparticles.

    PubMed

    Kim, Jin Sik; Song, Kyung Seuk; Sung, Jae Hyuck; Ryu, Hyun Ryol; Choi, Byung Gil; Cho, Hyun Sun; Lee, Jin Kyu; Yu, Il Je

    2013-08-01

    To clarify the health risks related to silver nanoparticles (Ag-NPs), we evaluated the genotoxicity, acute oral and dermal toxicity, eye irritation, dermal irritation and corrosion and skin sensitisation of commercially manufactured Ag-NPs according to the OECD test guidelines and GLP. The Ag-NPs were not found to induce genotoxicity in a bacterial reverse mutation test and chromosomal aberration test, although some cytotoxicity was observed. In acute oral and dermal toxicity tests using rats, none of the rats showed any abnormal signs or mortality at a dose level of ∼ 2000 mg/kg. Similarly, acute eye and dermal irritation and corrosion tests using rabbits revealed no significant clinical signs or mortality and no acute irritation or corrosion reaction for the eyes and skin. In a skin sensitisation test using guinea pigs, one animal (1/20) showed discrete or patchy erythema, thus Ag-NPs can be classified as a weak skin sensitiser.

  11. An Eye on Trafficking Genes: Identification of Four Eye Color Mutations in Drosophila

    PubMed Central

    Grant, Paaqua; Maga, Tara; Loshakov, Anna; Singhal, Rishi; Wali, Aminah; Nwankwo, Jennifer; Baron, Kaitlin; Johnson, Diana

    2016-01-01

    Genes that code for proteins involved in organelle biogenesis and intracellular trafficking produce products that are critical in normal cell function . Conserved orthologs of these are present in most or all eukaryotes, including Drosophila melanogaster. Some of these genes were originally identified as eye color mutants with decreases in both types of pigments found in the fly eye. These criteria were used for identification of such genes, four eye color mutations that are not annotated in the genome sequence: chocolate, maroon, mahogany, and red Malpighian tubules were molecularly mapped and their genome sequences have been evaluated. Mapping was performed using deletion analysis and complementation tests. chocolate is an allele of the VhaAC39-1 gene, which is an ortholog of the Vacuolar H+ ATPase AC39 subunit 1. maroon corresponds to the Vps16A gene and its product is part of the HOPS complex, which participates in transport and organelle fusion. red Malpighian tubule is the CG12207 gene, which encodes a protein of unknown function that includes a LysM domain. mahogany is the CG13646 gene, which is predicted to be an amino acid transporter. The strategy of identifying eye color genes based on perturbations in quantities of both types of eye color pigments has proven useful in identifying proteins involved in trafficking and biogenesis of lysosome-related organelles. Mutants of these genes can form the basis of valuable in vivo models to understand these processes. PMID:27558665

  12. Micro-RNAs and their roles in eye disorders.

    PubMed

    Raghunath, Azhwar; Perumal, Ekambaram

    2015-01-01

    Micro-RNAs (miRNAs) are members of the family of noncoding RNA molecules that regulate gene expression by translational repression and mRNA degradation. Initial identification of miRNAs revealed them only as developmental regulators; later, their radiated roles in various cellular processes have been established. They regulate several pathways, including developmental timing, hematopoiesis, organogenesis, apoptosis, cell differentiation and proliferation. Their roles in eye disorders are being explored by biologists around the world. Eye physiology requires the perfect orchestration of all the regulatory networks; any defect in any of the networks leads to eye disorders. The dysregulation of miRNA expression has been reported in many eye disorders, which paves the way for new therapeutics. This review summarizes the biogenesis of miRNAs and their role in eye disorders. miRNA studies also have implications for the understanding of various complex metabolic pathways leading to disorders of the eye. The ultimate understanding leads to potential opportunities in evaluating miRNAs as molecular biomarkers, prognostic tools, diagnostic tools and therapeutic agents for eye disorders. © 2015 S. Karger AG, Basel.

  13. Characteristics of eyes with inner retinal cleavage.

    PubMed

    Hwang, Young Hoon; Kim, Yong Yeon; Kim, Hwang Ki; Sohn, Yong Ho

    2015-02-01

    Inner retinal cleavage can be misdiagnosed as a glaucomatous retinal nerve fiber layer (RNFL) defect. This study was performed to characterize eyes with inner retinal cleavage. Inner retinal cleavage is defined as the appearance of a dark spindle-shaped space between the nerve fibers. Patients who presented at our institution with inner retinal cleavage were enrolled in the study. All participants were evaluated by fundus examination, visual field testing with standard automated perimetry, and optical coherence tomography (OCT) imaging. A total of 15 eyes of 11 subjects with inner retinal cleavage were included in the study. The median age of the subjects was 57 years (age range, 30-67 years). In each case, inner retinal cleavage was located adjacent to retinal blood vessels. Tissue bridging the cleavage area was observed in ten eyes. Six eyes had epiretinal membranes (ERMs), two eyes had glaucoma, and one eye had ERM in addition to glaucoma. Six eyes with inner retinal cleavage without combined ocular abnormalities had highly myopic refractive error (-6.50 to -8.50 diopters). Cross-sectional OCT images of the areas of inner retinal cleavage demonstrated defects with irregular margins and empty spaces in the inner layers of the retina. During the follow-up period, no eye showed changes in inner retinal layer cleavage or visual field sensitivity. Inner retinal cleavage was found in eyes with high myopia or ERMs. Inner retinal cleavage was associated with structural changes distinct from those associated with glaucomatous RNFL defects.

  14. Acidic mammalian chitinase in dry eye conditions.

    PubMed

    Musumeci, Maria; Aragona, Pasquale; Bellin, Milena; Maugeri, Francesco; Rania, Laura; Bucolo, Claudio; Musumeci, Salvatore

    2009-07-01

    An acidic mammalian chitinase (AMCase) seems to be implicated in allergic asthma and allergic ocular pathologies. The aim of this work was to investigate the role of AMCase during Sjögren's Syndrome (SS) and Meibomian Gland Dysfunction (MGD) dry eye diseases. Six patients with MGD dry eye (20-58 years, median 40) and six patients with dry eye associated to SS (32-60 years, median 47) were enrolled in this study. AMCase activity was measured in tears and AMCase mRNA expression was evaluated by real-time polymerase chain reaction from RNA extracted from epithelial cells of the conjunctiva. Six healthy adult subjects of the same age (34-44 years, median 39) were also studied as the control group. AMCase activity was significantly increased in patients affected by MGD dry eye (18.54 +/- 1.5 nmol/ml/h) and SS dry eye (8.94 +/- 1.0 nmol/ml/h) respectively, compared to healthy controls (1.6 +/- 0.2 nmol/ml/h). AMCase activity was higher in the tears of subjects with MGD dry eye (P < 0.001). AMCase mRNA was detected in conjunctival epithelial cells and the expression was significantly higher in MGD dry eye than SS dry eye. A significant correlation between AMCase activity in the tears and mRNA in conjunctival epithelial cells was found. AMCase may be an important marker in the pathogenesis of dry eye, suggesting the potential role of AMCase as a therapeutic target in these frequent pathologies.

  15. Repeatability Evaluation of a Contrast Sensitivity System for Transfer to the Eye Clinic

    NASA Astrophysics Data System (ADS)

    Alcalde, N. G.; Castillo, L. R.; Filgueira, C. Paz; Colombo, E. M.

    2016-04-01

    The Contrast Sensitivity Function (CSF) is a valuable tool which can be used to characterize functional vision and also for the diagnosis and management of patients with different eye diseases. In spite of its usefulness, the CSF is currently hardly ever used in clinical practice. The aim of this study was to validate the use of the system called FVC-100 (Tecnovinc-UNT-CONICET, Argentina), which calculates the CSF, in order to transfer this important tool to ophthalmological clinics. The validation was carried out through the design of a repeatability test and the subsequent analysis of the results. Furthermore, we evaluated the impact of different factors influencing the repeatability of the measurements such as age and previous training. The tests were based on the discrimination of sinusoidal gratings for different spatial frequencies (1, 4 and 12 c/°) in both eyes of 12 people, aged between 20 and 70. The results show that the calculated values of SC of each subject have a high repeatability and are not dependent on age or training. These results allow us to conclude positively regarding the effectiveness of the FVC-100, and to validate its use in clinics for the calculation of the FSC as a standard measure of functional vision quality.

  16. An optomechanical model eye for ophthalmological refractive studies.

    PubMed

    Arianpour, Ashkan; Tremblay, Eric J; Stamenov, Igor; Ford, Joseph E; Schanzlin, David J; Lo, Yuhwa

    2013-02-01

    To create an accurate, low-cost optomechanical model eye for investigation of refractive errors in clinical and basic research studies. An optomechanical fluid-filled eye model with dimensions consistent with the human eye was designed and fabricated. Optical simulations were performed on the optomechanical eye model, and the quantified resolution and refractive errors were compared with the widely used Navarro eye model using the ray-tracing software ZEMAX (Radiant Zemax, Redmond, WA). The resolution of the physical optomechanical eye model was then quantified with a complementary metal-oxide semiconductor imager using the image resolution software SFR Plus (Imatest, Boulder, CO). Refractive, manufacturing, and assembling errors were also assessed. A refractive intraocular lens (IOL) and a diffractive IOL were added to the optomechanical eye model for tests and analyses of a 1951 U.S. Air Force target chart. Resolution and aberrations of the optomechanical eye model and the Navarro eye model were qualitatively similar in ZEMAX simulations. Experimental testing found that the optomechanical eye model reproduced properties pertinent to human eyes, including resolution better than 20/20 visual acuity and a decrease in resolution as the field of view increased in size. The IOLs were also integrated into the optomechanical eye model to image objects at distances of 15, 10, and 3 feet, and they indicated a resolution of 22.8 cycles per degree at 15 feet. A life-sized optomechanical eye model with the flexibility to be patient-specific was designed and constructed. The model had the resolution of a healthy human eye and recreated normal refractive errors. This model may be useful in the evaluation of IOLs for cataract surgery. Copyright 2013, SLACK Incorporated.

  17. Antioxidant and inflammatory cytokine in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops.

    PubMed

    Jee, Donghyun; Park, Sang Hee; Kim, Man Soo; Kim, Eun Chul

    2014-07-03

    To compare the antioxidant and inflammatory cytokine activities in tears of patients with dry eye syndrome treated with preservative-free versus preserved eye drops. A total of 100 patients with moderate to severe dry eye syndrome were randomly divided into two groups. Fifty patients (group 1) were treated four times with preservative-free 0.1% sodium hyaluronate and 0.1% fluorometholone eye drops in the first month and with preservative-free 0.1% sodium hyaluronate and 0.05% cyclosporine eye drops in the second and third months. Another 50 patients (group 2) were treated with preserved eye drops on the same schedule. Ocular Surface Disease Index, corneal fluorescein staining, Schirmer I test, tear film breakup time, impression cytology, and antioxidant and inflammatory cytokine activities in tears were evaluated. Treatment with preservative-free eye drops led to significant improvements in symptoms, tear film breakup time, Schirmer I score, and impression cytologic findings compared to treatment with preserved eye drops (P < 0.05) in patients with dry eye syndrome. There was a statistically significant decrease in the IL-1β, IL-6, IL-12, and TNF-α concentrations and a statistically significant increase in the catalase, peroxiredoxin 2, superoxide dismutase 2 (SOD 2), and thioredoxin mean fluorescence intensity (MFI) of tears in the preservative-free group at 1, 2, and 3 months compared to initial values, respectively (P < 0.05). Treatment with preservative-free eye drops is effective against the dry eye syndrome. Preservative-free eye drops seem to be more effective than preserved eye drops in decreasing ocular inflammation and in increasing antioxidant contents in tears of patients with dry eye syndrome. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  18. Dry Eye Management: Targeting the Ocular Surface Microenvironment.

    PubMed

    Zhang, Xiaobo; M, Vimalin Jeyalatha; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo; Li, Wei

    2017-06-29

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment.

  19. Dry Eye Management: Targeting the Ocular Surface Microenvironment

    PubMed Central

    Zhang, Xiaobo; Jeyalatha M, Vimalin; Qu, Yangluowa; He, Xin; Ou, Shangkun; Bu, Jinghua; Jia, Changkai; Wang, Junqi; Wu, Han; Liu, Zuguo

    2017-01-01

    Dry eye can damage the ocular surface and result in mild corneal epithelial defect to blinding corneal pannus formation and squamous metaplasia. Significant progress in the treatment of dry eye has been made in the last two decades; progressing from lubricating and hydrating the ocular surface with artificial tear to stimulating tear secretion; anti-inflammation and immune regulation. With the increase in knowledge regarding the pathophysiology of dry eye, we propose in this review the concept of ocular surface microenvironment. Various components of the microenvironment contribute to the homeostasis of ocular surface. Compromise in one or more components can result in homeostasis disruption of ocular surface leading to dry eye disease. Complete evaluation of the microenvironment component changes in dry eye patients will not only lead to appropriate diagnosis, but also guide in timely and effective clinical management. Successful treatment of dry eye should be aimed to restore the homeostasis of the ocular surface microenvironment. PMID:28661456

  20. Real-time eye tracking for the assessment of driver fatigue.

    PubMed

    Xu, Junli; Min, Jianliang; Hu, Jianfeng

    2018-04-01

    Eye-tracking is an important approach to collect evidence regarding some participants' driving fatigue. In this contribution, the authors present a non-intrusive system for evaluating driver fatigue by tracking eye movement behaviours. A real-time eye-tracker was used to monitor participants' eye state for collecting eye-movement data. These data are useful to get insights into assessing participants' fatigue state during monotonous driving. Ten healthy subjects performed continuous simulated driving for 1-2 h with eye state monitoring on a driving simulator in this study, and these measured features of the fixation time and the pupil area were recorded via using eye movement tracking device. For achieving a good cost-performance ratio and fast computation time, the fuzzy K -nearest neighbour was employed to evaluate and analyse the influence of different participants on the variations in the fixation duration and pupil area of drivers. The findings of this study indicated that there are significant differences in domain value distribution of the pupil area under the condition with normal and fatigue driving state. Result also suggests that the recognition accuracy by jackknife validation reaches to about 89% in average, implying that show a significant potential of real-time applicability of the proposed approach and is capable of detecting driver fatigue.

  1. Real-time eye tracking for the assessment of driver fatigue

    PubMed Central

    Xu, Junli; Min, Jianliang

    2018-01-01

    Eye-tracking is an important approach to collect evidence regarding some participants’ driving fatigue. In this contribution, the authors present a non-intrusive system for evaluating driver fatigue by tracking eye movement behaviours. A real-time eye-tracker was used to monitor participants’ eye state for collecting eye-movement data. These data are useful to get insights into assessing participants’ fatigue state during monotonous driving. Ten healthy subjects performed continuous simulated driving for 1–2 h with eye state monitoring on a driving simulator in this study, and these measured features of the fixation time and the pupil area were recorded via using eye movement tracking device. For achieving a good cost-performance ratio and fast computation time, the fuzzy K-nearest neighbour was employed to evaluate and analyse the influence of different participants on the variations in the fixation duration and pupil area of drivers. The findings of this study indicated that there are significant differences in domain value distribution of the pupil area under the condition with normal and fatigue driving state. Result also suggests that the recognition accuracy by jackknife validation reaches to about 89% in average, implying that show a significant potential of real-time applicability of the proposed approach and is capable of detecting driver fatigue. PMID:29750113

  2. EYE DEVELOPMENT

    PubMed Central

    Baker, Nicholas E.; Li, Ke; Quiquand, Manon; Ruggiero, Robert; Wang, Lan-Hsin

    2014-01-01

    The eye has been one of the most intensively studied organs in Drosophila. The wealth of knowledge about its development, as well as the reagents that have been developed, and the fact that the eye is dispensable for survival, also make the eye suitable for genetic interaction studies and genetic screens. This chapter provides a brief overview of the methods developed to image and probe eye development at multiple developmental stages, including live imaging, immunostaining of fixed tissues, in situ hybridizations, and scanning electron microscopy and color photography of adult eyes. Also summarized are genetic approaches that can be performed in the eye, including mosaic analysis and conditional mutation, gene misexpression and knockdown, and forward genetic and modifier screens. PMID:24784530

  3. Eyes open versus eyes closed - Effect on human rotational responses

    NASA Technical Reports Server (NTRS)

    Wall, Conrad, III; Furman, Joseph M. R.

    1989-01-01

    The effect of eyelid closure on the response to rotational vestibular stimulation was assessed by evaluating 16 normal human subjects with both earth vertical axis (EVA) and earth horizontal axis (EHA) yaw rotations with either eyes closed (EC) or eyes open in the dark (EOD). Results indicated that for EVA rotation, the subjects' responses were of larger magnitude and less variable with EOD than with EC. However, for EHA rotation, responses were of larger magnitude and equally variable with EC as compared to EOD. Data also indicated that the quality of the EHA response with EC was altered because eyelid closure influenced the amount of periodic gaze. It is concluded that eyelid closure has an effect upon both canalocular and otolithocular reflexes and it is suggested that both EVA and EHA rotational testing be performed with EOD rather than with EC.

  4. Strengthening primary eye care in South Africa: An assessment of services and prospective evaluation of a health systems support package

    PubMed Central

    Lilian, Rivka R.; Railton, Jean; Schaftenaar, Erik; Mabitsi, Moyahabo; Grobbelaar, Cornelis J.; Khosa, N. Sellina; Maluleke, Babra H.; Struthers, Helen E.; McIntyre, James A.

    2018-01-01

    Visual impairment is a significant public health concern, particularly in low- and middle-income countries where eye care is predominantly provided at the primary healthcare (PHC) level, known as primary eye care. This study aimed to perform an evaluation of primary eye care services in three districts of South Africa and to assess whether an ophthalmic health system strengthening (HSS) package could improve these services. Baseline surveys were conducted in Cape Winelands District, Johannesburg Health District and Mopani District at 14, 25 and 36 PHC facilities, respectively. Thereafter, the HSS package, comprising group training, individual mentoring, stakeholder engagement and resource provision, was implemented in 20 intervention sites in Mopani District, with the remaining 16 Mopani facilities serving as control sites. At baseline, less than half the facilities in Johannesburg and Mopani had dedicated eye care personnel or sufficient space to measure visual acuity. Although visual acuity charts were available in most facilities, <50% assessed patients at the correct distance. Median score for availability of nine essential drugs was <70%. Referral criteria knowledge was highest in Cape Winelands and Johannesburg, with poor clinical knowledge across all districts. Several HSS interventions produced successful outcomes: compared to control sites there was a significant increase in the proportion of intervention sites with eye care personnel and resources such as visual acuity charts (p = 0.02 and <0.01, respectively). However, engaging with district pharmacists did not improve availability of essential drugs (p = 0.47). Referral criteria knowledge improved significantly in intervention sites (p<0.01) but there was no improvement in clinical knowledge (p = 0.76). Primary eye care in South Africa faces multiple challenges with regard to organisation of care, resource availability and clinical competence. The HSS package successfully improved some aspects of this

  5. Smooth pursuit eye movements and schizophrenia: literature review.

    PubMed

    Franco, J G; de Pablo, J; Gaviria, A M; Sepúlveda, E; Vilella, E

    2014-09-01

    To review the scientific literature about the relationship between impairment on smooth pursuit eye movements and schizophrenia. Narrative review that includes historical articles, reports about basic and clinical investigation, systematic reviews, and meta-analysis on the topic. Up to 80% of schizophrenic patients have impairment of smooth pursuit eye movements. Despite the diversity of test protocols, 65% of patients and controls are correctly classified by their overall performance during this pursuit. The smooth pursuit eye movements depend on the ability to anticipate the target's velocity and the visual feedback, as well as on learning and attention. The neuroanatomy implicated in smooth pursuit overlaps to some extent with certain frontal cortex zones associated with some clinical and neuropsychological characteristics of the schizophrenia, therefore some specific components of smooth pursuit anomalies could serve as biomarkers of the disease. Due to their sedative effect, antipsychotics have a deleterious effect on smooth pursuit eye movements, thus these movements cannot be used to evaluate the efficacy of the currently available treatments. Standardized evaluation of smooth pursuit eye movements on schizophrenia will allow to use specific aspects of that pursuit as biomarkers for the study of its genetics, psychopathology, or neuropsychology. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  6. Exploring the Predisposition of the Asian Eye to Development of Dry Eye.

    PubMed

    Craig, Jennifer P; Wang, Michael T M; Kim, Dabin; Lee, Jung Min

    2016-07-01

    To investigate the influence of eyelid shape on tear film quality, ocular surface characteristics and dry eye symptomatology by comparing Asian and Caucasian populations. Seventy-four age-matched participants were recruited in a cross-sectional study. Participants were classified into Asian single lid (ASL), Asian double lid (ADL), and Caucasian double lid (CDL) groups. Dry eye symptomatology, ocular surface characteristics, and tear film quality were evaluated in a single clinical session. Meibomian gland dropout was significantly greater in both the ASL and ADL groups than in the CDL group (all P<.05). A greater proportion of ASL and ADL participants exhibited incomplete blinking than CDL patients (all P<.05). There were no significant differences in tear film quality and dry eye symptomatology between the three groups (all P>.05). Exposed ocular surface area, lissamine green staining, and lid wiper epitheliopathy were significantly greater in the ADL group compared to the CDL group (all P<.05). The CDL group displayed significantly greater anterior blepharitis and lid telangiectasia grades compared to both ASL and ADL groups (all P<.05). A higher degree of meibomian gland dropout and incomplete blinking was observed in both Asian groups compared to the Caucasian group, potentially predisposing these groups to dry eye. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Eye Diseases

    MedlinePlus

    ... the back of the eye Macular degeneration - a disease that destroys sharp, central vision Diabetic eye problems ... defense is to have regular checkups, because eye diseases do not always have symptoms. Early detection and ...

  8. Chronic dry eye in PRK and LASIK: manifestations, incidence and predictive factors

    PubMed Central

    Bower, Kraig S.; Sia, Rose K.; Ryan, Denise S.; Mines, Michael J.; Dartt, Darlene A.

    2017-01-01

    Purpose To evaluate dry eye manifestations following photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) and determine the incidence and predictive factors of chronic dry eye using a set of dry eye criteria. Setting Walter Reed Army Medical Center, Washington, DC, USA Methods This is a prospective non-randomized clinical study of 143 active duty U.S. Army personnel aged 29.9±5.2 years with myopia or myopic astigmatism (manifest spherical equivalent −3.83±1.96 diopters) undergoing either PRK or LASIK. Dry eye evaluation was performed pre- and postoperatively. Main outcome measures included dry eye manifestations, incidence, and predictive factors of chronic dry eye. Results Schirmer scores, corneal sensitivity, ocular surface staining, surface regularity index (SRI), and responses to dry eye questionnaire significantly changed over time after PRK. After LASIK, significant changes were observed in tear breakup time, corneal sensitivity, ocular surface staining, and responses to questionnaire. At twelve months postoperatively, 5.0% of PRK and 0.8% of LASIK participants developed chronic dry eye. Regression analysis showed preoperatively lower Schirmer score will significantly influence development of chronic dry eye after PRK whereas preoperatively lower Schirmer score or higher ocular surface staining score will significantly influence the occurrence of chronic dry eye after LASIK. Conclusions Chronic dry eye is uncommon after PRK and LASIK. Ocular surface and tear film characteristics during preoperative examination may help predict chronic dry eye development in PRK and LASIK. PMID:26796443

  9. Eye Care Professionals' Perspectives on Eye Donation and an Eye Donation Registry for Research: A Single-Institution, Cross-Sectional Study.

    PubMed

    Williams, Andrew M; Allingham, R Rand; Stamer, W Daniel; Muir, Kelly W

    2016-06-01

    A centralized eye donation registry for research could help to bridge the gap between patients interested in donating their eyes to science and scientists who conduct research on human eye tissue. Previous research has demonstrated patient and family support for such a registry. In this study, we assessed the views that eye care professionals have toward an eye donation registry for research. Surveys were distributed to all 46 clinical faculty members of the Duke University Eye Center. In addition to collecting demographic information, the surveys assessed clinicians' experience with discussing eye donation with patients, described the proposed eye donation registry for research and asked how the registry would affect the clinicians' practice. A total of 21 eye care professionals returned the survey. Thirty-three percent reported discussing eye donation with patients, and 43% reported that a patient has asked about donating their eyes for research on their disease. Eighty-six percent of eye care professionals reported that a centralized registry would improve the way they work with patients who express a desire to donate their eyes for research. The majority of eye care professionals at our academic institution indicated that an eye donation registry for research would improve how they work with patients who are interested in donating their eyes for research on their disease. Future research should examine how best to communicate this registry to ophthalmic patients.

  10. The EyeHarp: A Gaze-Controlled Digital Musical Instrument

    PubMed Central

    Vamvakousis, Zacharias; Ramirez, Rafael

    2016-01-01

    We present and evaluate the EyeHarp, a new gaze-controlled Digital Musical Instrument, which aims to enable people with severe motor disabilities to learn, perform, and compose music using only their gaze as control mechanism. It consists of (1) a step-sequencer layer, which serves for constructing chords/arpeggios, and (2) a melody layer, for playing melodies and changing the chords/arpeggios. We have conducted a pilot evaluation of the EyeHarp involving 39 participants with no disabilities from both a performer and an audience perspective. In the first case, eight people with normal vision and no motor disability participated in a music-playing session in which both quantitative and qualitative data were collected. In the second case 31 people qualitatively evaluated the EyeHarp in a concert setting consisting of two parts: a solo performance part, and an ensemble (EyeHarp, two guitars, and flute) performance part. The obtained results indicate that, similarly to traditional music instruments, the proposed digital musical instrument has a steep learning curve, and allows to produce expressive performances both from the performer and audience perspective. PMID:27445885

  11. Ultrasonic biomicroscopy in ophthalmology and eye banking

    NASA Astrophysics Data System (ADS)

    Rosenwasser, George O. D.

    1999-06-01

    Echography has become a valuable diagnostic tool in ophthalmology. Ultrasonic biomicroscopy (UBM) in particular may be applied to the evaluation of small lesions of the anterior segment of the eye. Disease processes such as conjunctival and iris melanoma, other forms of neoplasia, intraocular cysts, narrow angle glaucoma, and intraocular foreign bodies can be diagnostically evaluated and followed longitudinally by UBM. Combining UBM with spectroscopy may become useful in determining cell type origins of a variety of tumors. Eye banking also has an increased need for UBM in corneal tissue banking. The recent development of the Laser In Situ Keratomileusis procedure has allowed corneal surgeries to create a partial thickness flap of tissue in the cornea, remove tissue from the base of the cornea with excimer laser ablation, and replace the hinged flap. This causes a substantial change in refractive error while thinning the cornea and leaving an interface within the corneal stroma. The ability to detect this type of surgery is essential in eye banking. Ultrasonic pachymetry to determine central thickness and biomicroscopy to detect the presence of an interface are essential in avoiding the use of these corneas for transplantation purposes. Determining the topography of the preserved corneas is another potential application for ultrasonography. Using this information to reduce optical aberration after transplant is crucial in improving visual performance post transplantation. A review of the anatomy of the eye, pathology of ocular diseases relevant to UBM, and principles of eye banking will be presented.

  12. ECEM (Eye Closure, Eye Movements): application to depersonalization disorder.

    PubMed

    Harriet, E Hollander

    2009-10-01

    Eye Closure, Eye Movements (ECEM) is a hypnotically-based approach to treatment that incorporates eye movements adapted from the Eye Movement Desensitization and Reprocessing (EMDR) protocol in conjunction with hypnosis for the treatment of depersonalization disorder. Depersonalization Disorder has been differentiated from post-traumatic stress disorders and has recently been conceptualized as a subtype of panic disorder (Baker et al., 2003; David, Phillips, Medford, & Sierra, 2004; Segui et. al., 2000). During ECEM, while remaining in a hypnotic state, clients self-generated six to seven trials of eye movements to reduce anticipatory anxiety associated with depersonalization disorder. Eye movements were also used to process triggers that elicited breath holding, often followed by episodes of depersonalization. Hypnotic suggestions were used to reverse core symptoms of depersonalization, subjectively described as "feeling unreal" (Simeon et al., 1997).

  13. Peripapillary Retinoschisis in Glaucomatous Eyes

    PubMed Central

    Lee, Eun Ji; Kim, Tae-Woo; Kim, Mijin; Choi, Yun Jeong

    2014-01-01

    Purpose To investigate the structural and clinical characteristics of peripapillary retinoschisis observed in glaucomatous eyes using spectral-domain optical coherence tomography (SD-OCT). Methods Circumpapillary retinal nerve fiber layer (cpRNFL) and macular cross-hair SD-OCT scans and infrared fundus images of the glaucoma patients from the Investigating Glaucoma Progression Study (IGPS) and healthy volunteers were reviewed. Optic disc images obtained using enhanced depth imaging (EDI) SD-OCT were also evaluated. The structural characteristics and clinical course of the retinoschisis associated with glaucoma were investigated. Results Twenty-five retinoschisis areas were found in 22 of the 372 patients (5.9%) included in the IGPS, and in 1 area in 1 of 187 healthy control subjects (0.5%). In the 22 glaucomatous eyes with retinoschisis, the schisis was attached to the optic disc and overlapped with the retinal nerve fiber layer (RNFL) defect. The RNFL was the layer most commonly affected by the retinoschisis, either alone or together with other deeper layers. Acquired optic disc pit was identified in 8 eyes on disc photography and/or B-scan images obtained by EDI SD-OCT. Spontaneous resolution of this condition was observed in nine eyes. No retinal detachment or macular involvement of the retinoschisis was observed in any of the eyes. Multivariate analysis showed a significant influence of a higher intraocular pressure at SD-OCT scanning on the presence of retinoschisis (Odds ratio  = 1.418, P = 0.001). Conclusions The present study investigated 22 cases of peripapillary retinoschisis in glaucomatous eyes. The retinoschisis was attached to the optic nerve and topographically correlated with RNFL defect. It often resolved spontaneously without causing severe visual disturbance. Care should be taken not to overestimate the RNFL thickness in eyes with retinoschisis, and also not to misinterpret the resolution of retinoschisis as a rapid glaucomatous RNFL

  14. Diabetes eye exams

    MedlinePlus

    Diabetic retinopathy - eye exams; Diabetes - eye exams; Glaucoma - diabetic eye exam; Macular edema - diabetic eye exam ... Ophthalmology Retina/Vitreous Panel. Preferred Practice Pattern ... www.aao.org/preferred-practice-pattern/diabetic-retinopathy- ...

  15. Comparison of ultrasound biomicroscopy and ultrasonographic parameters in eyes with phacomorphic glaucoma and eyes with mature cataract.

    PubMed

    Subbiah, Sujata; Thomas, Philip A; Nelson Jesudasan, C A

    2017-08-01

    To compare data on anatomical and biometric parameters, and their combination, obtained by using ultrasound biomicroscopy (UBM) and A-scan in eyes with phacomorphic glaucoma (PG) and eyes with mature cataract and to determine differences that may predispose to development of PG. Eighty patients (80 eyes) were enrolled in this cross-sectional study. Anterior chamber parameters, namely anterior chamber depth (ACD), angle-opening distance (AOD), iris-lens contact distance (ILCD), and trabecular-ciliary process distance (TCPD), among other parameters, were assessed by UBM (35 MHz), while axial length (AL) and lenticular thickness (LT) were determined by A-scan biometry. Absolute lenticular position (ALP) and relative lenticular position (RLP) were also compared. The mean AL of eyes with PG was less (P = 0.64) than the mean AL of eyes with mature cataract. The mean ILCD value in eyes with PG (1.30 ± 0.78 mm) was significantly higher (P = 0.0015) than that in eyes with mature cataract (0.86 ± 0.32 mm). The mean AOD value in eyes with PG (0.15 ± 0.10 mm) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.23 ± 0.06 mm); similarly, the mean RLP value in eyes with PG (0.20 ± 0.02) was significantly lower (P < 0.0001) than that in eyes with mature cataract (0.17 ± 0.02). TCPD showed negative correlation with LT r = -0.514; P = 0.017, r 2  = 0.264, in eyes with phacomorphic glaucoma and mature cataracts showed significant negative correlation of ILCD with AL (r = -0.575; P = 0.025, r 2  = 0.330). The results of UBM examination suggest that there are multiple mechanisms underlying the pathophysiology of PG, namely crowding of the anterior segment, increased iris-lens contact distance, and a more pronounced anterior shift of the lens. Simultaneous evaluation of anatomic and biometric parameters can improve diagnostic accuracy in predicting cases at risk for PG.

  16. [A correct understanding of preservatives in eye drops].

    PubMed

    Liu, Zuguo; Huang, Caihong

    2015-09-01

    Eye drops are the most commonly used preparations in ophthalmology. Preservatives are usually added in order to protect eye drops against pathogenic organisms and increase the solubility of the drugs in multi-dose containers. Ophthalmologists have paid a lot of attention to the preservatives in eye drops because they remain one of the main reasons for ocular surface damage, and even may lead to serious visual impairment in patients with inappropriate use of eye drops. However, it should be noted that the dangers of preservatives become overstated nowadays. It is necessary to completely evaluate the effects of preservatives in ophthalmic preparations, so that ophthalmologists can guide patients to correctly select eye drops containing preservatives and avoid dangerous side effects, according to their eye disease situation, state of tear function and ocular surface changes, cultural background and financial income, cost and benefit and convenience of the use of drugs, and other factors. The direction of the future development in this field is to establish the clinical guideline for use of eye drops containing preservatives, carry out continuing education courses on preservatives and develop ideal preservatives.

  17. Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes.

    PubMed

    Detorakis, Efstathios T; Drakonaki, Eleni E; Ginis, Harilaos; Karyotakis, Nikolaos; Pallikaris, Ioannis G

    2014-01-01

    A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.

  18. Additive Effect of preservative-free sodium hyaluronate 0.1% in treatment of dry eye syndrome with diquafosol 3% eye drops.

    PubMed

    Hwang, Ho Sik; Sung, Yoon-Mi; Lee, Weon Sun; Kim, Eun Chul

    2014-09-01

    The aim of this study was to evaluate the treatment effect of diquafosol 3% with preservative-free sodium hyaluronate 0.1% eye drops in dry eye syndrome. In total, 150 patients with dry eye syndrome were divided randomly into 3 groups. Group 1 (50 patients) was treated 4 times daily with preserved sodium hyaluronate 0.1%, group 2 (50 patients) was treated 4 times daily with diquafosol 3%, and group 3 (50 patients) was treated 4 times daily with diquafosol 3% and preservative-free sodium hyaluronate 0.1% eye drops for 3 months. Ocular surface disease index (OSDI) score, tear film break-up time, Schirmer I test, corneal fluorescein staining, and impression cytology were evaluated. There were significant improvements in the OSDI score, tear film break-up time, Schirmer I score, fluorescein and Rose Bengal staining, goblet cell density, and impression cytological findings in groups 2 and 3 compared with those for group 1 in patients with dry eye syndrome at 1, 2, and 3 months (P < 0.05). There were statistically significant improvements in the OSDI score (-8.48 ± 0.97, -5.69 ± 0.78; P = 0.02), fluorescein (-1.43 ± 0.21, -1.02 ± 0.18; P = 0.03), and Rose Bengal staining (-1.12 ± 0.26, -0.75 ± 0.12; P = 0.03), goblet cell density (89.65 ± 14.39, 70.36 ± 16.75; P = 0.03), and impression cytological findings (-0.53 ± 0.12, -0.34 ± 0.90; P = 0.01) in group 3 compared with those in group 2 at 3 months. Treatment with diquafosol 3% with preservative-free sodium hyaluronate 0.1% was more effective than diquafosol 3% monotherapy or treatment with preserved sodium hyaluronate 0.1% in dry eye syndrome. Preservative-free sodium hyaluronate 0.1% eye drops can increase the effect of diquafosol 3% in dry eye syndrome.

  19. Evaluating a Tablet Application and Differential Reinforcement to Increase Eye Contact in Children with Autism

    ERIC Educational Resources Information Center

    Jeffries, Tricia; Crosland, Kimberly; Miltenberger, Raymond

    2016-01-01

    We tested the effectiveness of a tablet application and differential reinforcement to increase eye contact in 3 children with autism. The application required the child to look at a picture of a person's face and identify the number displayed in the person's eyes. Eye contact was assessed immediately after training, 1 hr after training, and in a…

  20. FogEye UV Sensor System Performance Characteristics

    DOT National Transportation Integrated Search

    2004-03-01

    The primary objective of the FogEye Evaluation Program is to determine whether coupled ultra-violet sources and detectors may provide enhancements to safety on the airport surface. The results of this effort will be used to complete the evaluation of...

  1. The eye amputated - consequences of eye amputation with emphasis on clinical aspects, phantom eye syndrome and quality of life.

    PubMed

    Rasmussen, Marie Louise Roed

    2010-12-01

    In this thesis the term eye amputation (EA) covers the removing of an eye by: evisceration, enucleation and exenteration. Amputation of an eye is most frequently the end-stage in a complicated disease, or the primary treatment in trauma and neoplasm. In 2010 the literature is extensive due to knowledge about types of surgery, implants and surgical technique. However, not much is known about the time past surgery. To identify the number of EA, the causative diagnosis and the indication for surgical removal of the eye, the chosen surgical technique and to evaluate a possible change in surgical technique in Denmark from 1996 until 2003 (paper I); To describe the phantom eye syndrome and its prevalence of visual hallucinations, phantom pain and phantom sensations (paper II); To characterise the quality of phantom eye pain, including its intensity and frequency among EA patients. We attempted to identify patients with increased risk of developing pain after EA and investigated if preoperative pain is a risk factor for a later development of phantom pain (paper III); In addition we wanted to investigate the health related quality of life, perceived stress, self rated health, job separation due to illness or disability and socio-economic position of the EA in comparison with the general Danish population (paper IV). Records on 431 EA patients, clinical ophthalmological examination and an interview study of 173 EA patients and a questionnaire answered by 120 EA patients. The most frequent indications for EA in Denmark were painful blind eye (37%) and neoplasm (34%). During the study period 1996-2003, the annual number of eye amputations was stable, but an increase in bulbar eviscerations was noticed. Orbital implants were used with an increasing tendency until 2003. The Phantom eye syndrome is frequent among EA patients. Visual hallucinations were described by 42% of the patients. The content were mainly elementary visual hallucinations, with white or colored light as a

  2. Eye Movement Disorders

    MedlinePlus

    ... t work properly. There are many kinds of eye movement disorders. Two common ones are Strabismus - a disorder ... of the eyes, sometimes called "dancing eyes" Some eye movement disorders are present at birth. Others develop over ...

  3. Conjunctivitis (Pink Eye)

    MedlinePlus

    ... you can put on your web pages. Conjunctivitis (Pink Eye) One-Page Overview Pink, itchy eyes? Conjunctivitis – or ... protect yourself from getting and spreading pink eye . Pink Eye: What To Do Discusses causes and treatment, when ...

  4. Manifestation of meibomian gland dysfunction in patients with Sjögren's syndrome, non-Sjögren's dry eye, and non-dry eye controls.

    PubMed

    Kang, Yeon Soo; Lee, Hyo Seok; Li, Ying; Choi, Won; Yoon, Kyung Chul

    2018-06-01

    To evaluate the manifestation of meibomian gland dysfunction in patients with Sjögren's syndrome (SS), non-Sjögren's syndrome dry eye (non-SS) patients, and non-dry eye controls. We recruited 31 participants with SS dry eye, 30 participants with non-SS dry eye, and 35 healthy controls without dry eye symptoms. Noninvasive tear breakup time (NITBUT) and meibomian gland dropout score (meiboscore) were measured using the Oculus Keratograph 5 M. Meibomian gland expressibility and secretion quality were evaluated via slit lamp biomicroscopy. The correlation between measurements was analyzed. NITBUT was lower, and the meiboscore, meibomian gland expressibility, and secretion quality scores were significantly higher in the SS and non-SS groups than in the control group (p < 0.001). NITBUT was lower, and the meiboscore and meibomian gland expressibility were higher in the SS group than in the non-SS group. NITBUT correlated negatively with the meiboscore in both SS and non-SS groups and with meibomian gland expressibility in the SS group. A positive correlation was obtained between meiboscore and meibomian gland expressibility in both the SS and the non-SS groups. Patients in both SS and non-SS groups exhibited greater impairment in meibomian gland function than the non-dry eye controls. SS patients had more severe meibomian gland dysfunction with poorer mean meiboscore and meibomian gland expressibility than non-SS patients.

  5. Pupillographic evaluation of the time course of atropine effects in the mouse eye.

    PubMed

    Schaeffel, Frank; Burkhardt, Eva

    2005-03-01

    The nonselective muscarinic antagonist atropine is currently the most potent drug against myopia development in both humans and animal models. However, the mechanism by which myopia is suppressed is still unknown, and the time course of its action is not well documented. Therefore, we have studied the duration of mydriasis in the mouse, a new model of myopia, after topical application of a single eye drop with different doses of atropine. The light-induced pupil response of the C57BL/6 (B6) wildtype strain was studied in alert mice that were restrained by grasping their necks. A video image-processing program detected the pupil and measured its diameter at 25 Hz sampling rate. To stimulate, an arrangement of green LEDs, which was attached to the recording video camera, could be flashed for 40 ms by pressing a key on the keyboard. A single drop of atropine solution (1, 0.5, or 0.1%) was instilled in one eye and the recovery of the pupil responses was followed for at least 150 h. Both eyes were measured. 1) Under the defined stimulation conditions, untreated wildtype mice displayed a pupil constriction of 23.7 +/- 2.4%. 2) All doses of atropine caused complete suppression of the pupil responses in the treated eyes within 1 min. 3) The pupil responses of the fellow eyes remained unaffected and were not different from those in untreated animals. 4) The recovery from mydriasis was very slow and did not show clear differences with dose. The extrapolated duration of complete recovery was about 10 d (0.1%: 217 h; 0.5%: 230 h; 1%: 294 h). Atropine caused a longlasting suppression of the pupil responses in the mouse eye. That the duration of recovery was not obviously dose-dependent suggests that all doses used in this study were saturating the receptors in the iris musculature.

  6. Plasma Rich in Growth Factors for the Treatment of Dry Eye after LASIK Surgery.

    PubMed

    Sanchez-Avila, Ronald Mauricio; Merayo-Lloves, Jesus; Fernandez, Maria Laura; Rodriguez-Gutierrez, Luis Alberto; Jurado, Nancy; Muruzabal, Francisco; Orive, Gorka; Anitua, Eduardo

    2018-06-08

    The aim of this study was to evaluate the use of plasma rich in growth factors (PRGF) eye drops in patients with dry eye disease after laser-assisted in situ keratomileusis (LASIK) surgery. This is a longitudinal, retrospective, comparative, and descriptive study of 77 eyes of 42 patients with dry eye disease following LASIK surgery. This study was designed to evaluate the efficacy of PRGF treatment compared to conventional therapy (control group). Outcome measures including signs and symptoms of dry eye disease were evaluated before and after treatment. The percentage of change before and after treatment for each clinical variable measured was compared between both groups. There were 1-4 treatment cycles with PRGF eye drops (1 cycle = 6 weeks). Results showed a statistically significant improvement in the Ocular Surface Disease Index (38.12%), visual analogue scale scores for frequency (41.89%) and severity (42.47%), and the Schirmer test scores (88.98%) after PRGF treatment (p < 0.05). No adverse events were reported after PRGF treatment. These results suggest that PRGF eye drops are effective for the improvement of dry eye symptoms in patients who underwent LASIK surgery in comparison to the conventional therapy. The treatment with PRGF is an alternative for patients who suffer from postoperative dry eye. © 2018 S. Karger AG, Basel.

  7. Effect of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye.

    PubMed

    Koh, Shizuka; Maeda, Naoyuki; Ikeda, Chikako; Oie, Yoshinori; Soma, Takeshi; Tsujikawa, Motokazu; Watanabe, Hitoshi; Nishida, Kohji

    2014-12-01

    To investigate the short- and long-term effects of diquafosol ophthalmic solution on the optical quality of the eyes in patients with aqueous-deficient dry eye. Sixteen eyes in 16 patients with mild or moderate aqueous-deficient dry eye were treated with 3% diquafosol ophthalmic solution. Ocular higher-order aberrations (HOAs) were measured with a wavefront sensor before and at 15 min after diquafosol instillation at the baseline visit and at 4 weeks after treatment initiation. Dry eye symptoms, tear break-up time (BUT), corneal/conjunctival fluorescein staining and Schirmer's test were also evaluated before and after treatment with diquafosol. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining and BUT. Compared with mean total HOAs at baseline (0.180 ± 0.06 μm), those at 4 weeks after treatment significantly decreased (0.148 ± 0.039 μm; p = 0.035), whereas those 15 min after diquafosol instillation at the baseline visit did not change significantly (0.170 ± 0.049 μm; p = 0.279). Although no significant change in HOAs was observed as a short-term effect of a single-drop instillation of diquafosol, long-term use of diquafosol to treat aqueous-deficient dry eye reduced HOAs as well as improved corneal epithelial damage and tear film stability. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Allergic conjunctivitis and dry eye syndrome.

    PubMed

    Hom, Milton M; Nguyen, Andrew L; Bielory, Leonard

    2012-03-01

    Allergic conjunctivitis (AC) and dry eye syndrome (DES) are 2 of the most common anterior inflammatory disorders of the ocular surface and one does not preclude the coexistence of the other. To examine the potential overlap between AC and DES as comorbidities. Using the validated questionnaire known as Subjective Evaluation of Symptom of Dryness, we studied self-reported itchiness, dryness, and redness. In an outpatient optometric setting, 689 patients treated from January 1, 2007, to January 1, 2011, were surveyed for their ocular history and categorized according to their reported level of discomfort of itchiness, dryness, and redness. Patients ranged in age from 5 to 90 years (median age, 25 years; 39.5% male; 60.5% female). In the studied 689 patients, clinically significant itchiness was found in 194 (28.2%), dry eyes in 247 (35.8%), and redness in 194 (28.2%). Symptom overlap was demonstrated in many of the patients. Of the 194 patients with itchiness, 112 (57.7%) had clinically significant dryness. In the 247 patients with dry eyes, 112 (45.3%) had clinically significant itch. Redness was apparent in 120 of the 194 patients with itch (61.9%) and 122 of the 247 patients with dryness (49.4%). Statistical analysis demonstrated that self-reported itchiness, dryness, and redness were not independent of each other (P<.001; Pearson χ(2) test). The odds of patients with "itchy eyes" also experiencing dry eyes were 2.11 times and the odds of these patients also experiencing redness were 7.34 times that of patients with nonitchy eyes. Most patients with "itchy eyes" consistent with AC also have dry eyes and redness. These results suggest that some symptomatic patients concomitantly have features of AC and DES. Copyright © 2012 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  9. Evaluating and Reporting Data Quality in Eye Movement Research. Technical Report No. 193.

    ERIC Educational Resources Information Center

    McConkie, George W.

    Stressing that it is necessary to have information about the quality of eye movement data in order to judge the degree of confidence one should have in the results of an experiment using eye movement records as data, this report suggests ways for assessing and reporting such information. Specifically, the report deals with three areas: (1)…

  10. Eye Gaze during Observation of Static Faces in Deaf People

    PubMed Central

    Watanabe, Katsumi; Matsuda, Tetsuya; Nishioka, Tomoyuki; Namatame, Miki

    2011-01-01

    Knowing where people look when viewing faces provides an objective measure into the part of information entering the visual system as well as into the cognitive strategy involved in facial perception. In the present study, we recorded the eye movements of 20 congenitally deaf (10 male and 10 female) and 23 (11 male and 12 female) normal-hearing Japanese participants while they evaluated the emotional valence of static face stimuli. While no difference was found in the evaluation scores, the eye movements during facial observations differed among participant groups. The deaf group looked at the eyes more frequently and for longer duration than the nose whereas the hearing group focused on the nose (or the central region of face) more than the eyes. These results suggest that the strategy employed to extract visual information when viewing static faces may differ between deaf and hearing people. PMID:21359223

  11. Quality of life of eye amputated patients.

    PubMed

    Rasmussen, Marie L R; Ekholm, Ola; Prause, Jan U; Toft, Peter B

    2012-08-01

    To evaluate eye-amputated patients' health-related quality of life, perceived stress, self-rated health, job separation because of illness or disability and socioeconomic position. Patients were recruited from a tertiary referral centre situated in Copenhagen. Inclusion criteria were eye amputation, i.e. evisceration, enucleation, orbital exenteration or secondary implantation of an orbital implant during the period 1996-2003, and participation in a previous investigation (2005). In total, 159 eye-amputated patients were included, and completed a self-administered questionnaire containing health-related quality of life (SF-36), the perceived stress scale and answered questions about self-rated health, job changes because of illness or disability and socioeconomic status. These results were compared with findings from the Danish Health Interview Survey 2005. The eye-amputated patients had significantly (p < 0.05) lower scores (poorer health) on all SF-36 subscales and more perceived stress compared to the general population. In all, 43.3% of the patients rated their health as excellent or very good compared to 52.1% of the general population. In total, 25% of the study population has retired or changed to a part-time job because of eye disease. The percentage of eye amputated patients, who were divorced or separated, was twice as high as in the general population. The impact of an eye amputation is considerable. The quality of life, perceived stress and self-rated health of many eye-amputated patients are drastically changed. Eye amputation has a marked negative influence on job separation because of illness or disability and on socioeconomic position. © 2011 The Authors. Acta Ophthalmologica © 2011 Acta Ophthalmologica Scandinavica Foundation.

  12. Traumatic eye injuries as a result of blunt impact

    NASA Astrophysics Data System (ADS)

    Clemente, Chiara; Esposito, Luca; Bonora, Nicola; Limido, Jerome; Lacome, Jean-Luc; Rossi, Tommaso

    2013-06-01

    The detachment or tearing of the retina in the human eye as a result of a collision is a phenomenon that occurs very often. This research is aimed at identifying and understanding the actual dynamic physical mechanisms responsible for traumatic eye injuries accompanying blunt impact, with particular attention to the damage processes that take place at the retina. To this purpose, a numerical and experimental investigation of the dynamic response of the eye during an impact event was performed. Numerical simulation of both tests was performed with IMPETUS-FEA, a general non-linear finite element software which offers NURBS finite element technology for the simulation of large deformation and fracture in materials. Computational results were compared with the experimental results on fresh enucleated porcine eyes impacted with airsoft pellets. The eyes were placed in a container filled with 10 percent ballistic gelatin simulating the fatty tissue surrounding the eye. A miniature pressure transducer was inserted into the eye bulb through the optic nerve in order to measure the pressure of the eye during blunt-projectile impacts. Each test was recorded using a high speed video camera. The ocular injuries observed in the impacted eyes were assessed by an ophthalmologist in order to evaluate the correlation between the pressure measures and the risk of retinal damage.

  13. Dry eye and meibomian gland dysfunction in pseudophakic bullous keratopathy.

    PubMed

    Palamar, Melis; Kiyat, Pelin; Yagci, Ayse

    2018-02-01

    To evaluate dry eye tests and meibography of patients with pseudophakic bullous keratopathy (PBK). Thirty-seven patients with PBK were included. The eyes with PBK were compared with the normal pseudophakic fellow eyes. All patients had undergone a detailed ophthalmic examination including corneal and conjunctival fluorescein staining and Oxford scoring, tear film breakup time, Schirmer 1 test, Ocular Surface Disease Index (OSDI) score assessment, lid margin abnormalities, upper and lower eyelid Meibomian gland evaluation using infrared captures of a biomicroscope. Partial or complete loss of the Meibomian glands (Meibomian dropout) was scored for each eyelid from grade 0 (no loss) through grade 3 (lost area was > 2/3 of the total meibomian gland area). The mean age of the patients was 73.2 ± 8.9 (range, 50-93). Mean tear film breakup time value was statistically lower in PBK eyes (P ≤ 0.001). OSDI, Oxford, lid margin abnormalities, inferior meibography, total meibography score were significantly higher in PBK eyes (P ≤ 0.001). The comparison of Schirmer 1 and superior meibography scores of the groups was insignificant (P = 0.143, P = 0.793, respectively). The Meibomian gland morphology of the PBK eyes demonstrates significant differences when compared with normal fellow eyes and might be related to evaporative dry eye. For this reason, patients with PBK should be monitored for Meibomian gland dysfunction and when needed start prompt treatment in order to prevent further disturbance of the ocular surface.

  14. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses

    PubMed Central

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776

  15. Evaluation of refractive correction for standard automated perimetry in eyes wearing multifocal contact lenses.

    PubMed

    Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki

    2017-01-01

    To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.

  16. Semantic Evaluation of Syntactic Structure: Evidence from Eye Movements

    ERIC Educational Resources Information Center

    Frazier, Lyn; Carminati, Maria Nella; Cook, Anne E.; Majewski, Helen; Rayner, Keith

    2006-01-01

    An eye movement study of temporarily ambiguous closure sentences confirmed that the early closure penalty in a sentence like "While John hunted the frightened deer escaped" is larger for a simple past verb ("hunted") than for a past progressive verb ("was hunting"). The results can be explained by the observation that simple past tense verbs…

  17. Improving access to eye health services in rural Timor-Leste.

    PubMed

    Pereira, Sara M; Blignault, Ilse; du Toit, Renee; Ramke, Jacqueline

    2012-01-01

    Delivering eye health services to people in rural areas, especially in fragile, post-conflict countries, is a major challenge. This article reports on the implementation and evaluation of an innovative district-based outreach service. The main project partners were the Timor-Leste Ministry of Health and an international non-government organization, with assistance from a local non-government organization. An eye care nurse in Covalima District, a remote location 178 km from Timor-Leste's capital, Dili, was provided with a motor-bike for transport and regular support for outreach eye services to sub-district facilities. Data collected over the first year of operation were examined and included: services provided, spectacles dispensed, health promotion activities conducted and the cost of providing these. The project was also evaluated for its relevance, effectiveness, efficiency, impact and sustainability. In the first 12 months, 55 outreach visits were conducted across the district's seven sub-districts during which 1405 people received vision screening, and 777 spectacles were dispensed. In addition to meeting the five evaluation criteria, compared with the hospital-based eye clinic the outreach service resulted in significantly greater gender equity among eye health service beneficiaries. This pilot project demonstrates what can be achieved when a Ministry of Health (central and district level) and non-government organizations (international and local) work in partnership to support a dedicated health care provider.

  18. 'Behind blue eyes'†: the association between eye colour and deep infiltrating endometriosis.

    PubMed

    Vercellini, Paolo; Buggio, Laura; Somigliana, Edgardo; Dridi, Dhouha; Marchese, Maria Antonietta; Viganò, Paola

    2014-10-10

    Is the prevalence of blue eye colour higher in women with deep endometriosis? Blue eye colour is more common in women with deep endometriosis when compared with both women with ovarian endometriomas and women without a history of endometriosis. Recent and intriguing evidence suggests that women with deep endometriosis may have particular phenotypic characteristics including a higher prevalence of a light-colour iris. Available epidemiological evidence is however weak. Case-control study performed in a large academic department specializing in the study and treatment of endometriosis. Individual iris colour was evaluated in daylight and categorized in three grades, namely blue-grey (blue), hazel-green (green) and brown. One observer assessed iris colour. In addition, the women themselves were invited to indicate the colour of their eyes according to the same classification system. Cases with discordant eye colour determinations between the observer and the woman were excluded from the final analysis. Two hundred and twenty-three women with deep endometriosis (cases), 247 with ovarian endometriomas and 301 without a history of endometriosis were enrolled. After exclusion of 52 discordant cases, the proportions of brown, blue and green eye colours were, respectively, 61, 30 and 9% in the deep endometriosis group, 74, 16 and 10% in the endometrioma group and 75, 15 and 10% in the non-endometriosis group. Women in the deep endometriosis group had a statistically significant excess of blue eyes and a reduced proportion of brown eyes compared with the two control groups (P = 0.002 and P < 0.001, respectively). The proportion of blue eyes was almost identical in the ovarian endometrioma group and the non-endometriosis group, and that of green eyes was substantially similar in all study groups. The OR (95% CI) of having blue eyes in women with deep endometriosis compared with women with ovarian endometriosis and with those without endometriosis was, respectively, 2.2 (1

  19. Prevalence of Dry Eye in Uyghur and Han Ethnic Groups in Western China.

    PubMed

    Gong, Ying-Ying; Zhang, Fan; Zhou, Jin; Li, Jing; Zhang, Guang-Hui; Wang, Jun-Liang; Gu, Zhen-Sheng

    2017-06-01

    To describe and compare the prevalence and characteristics of dry eye among Han and Uyghur persons living in Kashi, the most inland city of China. A total of 1015 residents of Kashi participated in this 2013 cross-sectional study. To evaluate clinical characteristics, each subject completed (1) a dry-eye questionnaire detailing symptoms of dry eye, (2) Schirmer's I-test (SIT), (3) tear-film break-up time (BUT) test, and fluorescein staining of the cornea. Dry eye was defined as the existence of dry eye symptoms and at least two positive clinical signs. Data were analyzed using SPSS software. The prevalence and risk factors of dry eye were evaluated using a multivariate model. Overall, 282 (27.8%) of the 1015 participants were diagnosed with dry eye (95% confidence interval (CI): range, 25.5-30.1). The prevalence of dry eye among Han persons (37.9 %) (95% CI: range, 35.8-40.0) was higher than that among Uyghurs (21.8%) (95% CI: 19.6-24.0) (p < 0.05). The prevalence of dry eye was 25.6% (95% CI: range, 23.3-27.8) among men and 28.7% (95% CI: 26.5-30.9) among women (p > 0.05). Risk factors for dry eye included ethnicity, age, occupation, arthritis, and dry mouth. Our study revealed a higher prevalence of dry eye among Han than Uyghur persons in Kashi. Dry eye was significantly associated with environment and ethnicity.

  20. An eye model for uncalibrated eye gaze estimation under variable head pose

    NASA Astrophysics Data System (ADS)

    Hnatow, Justin; Savakis, Andreas

    2007-04-01

    Gaze estimation is an important component of computer vision systems that monitor human activity for surveillance, human-computer interaction, and various other applications including iris recognition. Gaze estimation methods are particularly valuable when they are non-intrusive, do not require calibration, and generalize well across users. This paper presents a novel eye model that is employed for efficiently performing uncalibrated eye gaze estimation. The proposed eye model was constructed from a geometric simplification of the eye and anthropometric data about eye feature sizes in order to circumvent the requirement of calibration procedures for each individual user. The positions of the two eye corners and the midpupil, the distance between the two eye corners, and the radius of the eye sphere are required for gaze angle calculation. The locations of the eye corners and midpupil are estimated via processing following eye detection, and the remaining parameters are obtained from anthropometric data. This eye model is easily extended to estimating eye gaze under variable head pose. The eye model was tested on still images of subjects at frontal pose (0 °) and side pose (34 °). An upper bound of the model's performance was obtained by manually selecting the eye feature locations. The resulting average absolute error was 2.98 ° for frontal pose and 2.87 ° for side pose. The error was consistent across subjects, which indicates that good generalization was obtained. This level of performance compares well with other gaze estimation systems that utilize a calibration procedure to measure eye features.

  1. Greek mythology: the eye, ophthalmology, eye disease, and blindness.

    PubMed

    Trompoukis, Constantinos; Kourkoutas, Dimitrios

    2007-06-01

    In distant eras, mythology was a form of expression used by many peoples. A study of the Greek myths reveals concealed medical knowledge, in many cases relating to the eye. An analysis was made of the ancient Greek texts for mythological references relating to an understanding of vision, visual abilities, the eye, its congenital and acquired abnormalities, blindness, and eye injuries and their treatment. The Homeric epics contain anatomical descriptions of the eyes and the orbits, and an elementary knowledge of physiology is also apparent. The concept of the visual field can be seen in the myth of Argos Panoptes. Many myths describe external eye disease ("knyzosis"), visual disorders (amaurosis), and cases of blinding that, depending on the story, are ascribed to various causes. In addition, ocular motility abnormalities, congenital anomalies (cyclopia), injuries, and special treatments, such as the "licking" method, are mentioned. The study of mythological references to the eye reveals reliable medical observations of the ancient Greeks, which are concealed within the myths.

  2. Changes of the eye optics after iris constriction☆

    PubMed Central

    Montés-Micó, Robert; Hernández, Patricio; Fernández-Sánchez, Vicente; Bonaque, Sergio; Lara, Francisco; López-Gil, Norberto

    2011-01-01

    Purpose To evaluate the possible change in the optics of the human eye after iris constriction. Methods Ocular aberrations were measured under natural viewing conditions in 26 eyes. The measured eyes fixated on a dim target while the contralateral eye was either occluded (so the measured eye had a large pupil) or highly illuminated (so the measured eye had a small pupil). The measured eyes fixated to a dim target placed 0.5 D beyond the subject’s far point. Zernike values obtained in both situations were compared within the same pupil diameter corresponding to the one obtained under the high illumination condition. Results Significant variation in some aberration coefficients were found between the two illumination conditions. Specially, spherical aberration (SA) increased significantly after pupil miosis (P = .0017). The mean increase of SA measured was 0.018 microns, for a 3-mm pupil. Mean values of other ocular aberrations also vary significantly after pupil miosis (changes were larger than the standard deviation of the repeated measurements). A mean paraxial hyperopic shift of one third of diopter was found after iris constriction. Conclusion Iris constriction slightly modifies the optics of the eye. The small hyperopic shift of the best image plane after iris constriction may be explained by a change in the lens shape and/or position.

  3. Quantitative Assessment of Eye Phenotypes for Functional Genetic Studies Using Drosophila melanogaster

    PubMed Central

    Iyer, Janani; Wang, Qingyu; Le, Thanh; Pizzo, Lucilla; Grönke, Sebastian; Ambegaokar, Surendra S.; Imai, Yuzuru; Srivastava, Ashutosh; Troisí, Beatriz Llamusí; Mardon, Graeme; Artero, Ruben; Jackson, George R.; Isaacs, Adrian M.; Partridge, Linda; Lu, Bingwei; Kumar, Justin P.; Girirajan, Santhosh

    2016-01-01

    About two-thirds of the vital genes in the Drosophila genome are involved in eye development, making the fly eye an excellent genetic system to study cellular function and development, neurodevelopment/degeneration, and complex diseases such as cancer and diabetes. We developed a novel computational method, implemented as Flynotyper software (http://flynotyper.sourceforge.net), to quantitatively assess the morphological defects in the Drosophila eye resulting from genetic alterations affecting basic cellular and developmental processes. Flynotyper utilizes a series of image processing operations to automatically detect the fly eye and the individual ommatidium, and calculates a phenotypic score as a measure of the disorderliness of ommatidial arrangement in the fly eye. As a proof of principle, we tested our method by analyzing the defects due to eye-specific knockdown of Drosophila orthologs of 12 neurodevelopmental genes to accurately document differential sensitivities of these genes to dosage alteration. We also evaluated eye images from six independent studies assessing the effect of overexpression of repeats, candidates from peptide library screens, and modifiers of neurotoxicity and developmental processes on eye morphology, and show strong concordance with the original assessment. We further demonstrate the utility of this method by analyzing 16 modifiers of sine oculis obtained from two genome-wide deficiency screens of Drosophila and accurately quantifying the effect of its enhancers and suppressors during eye development. Our method will complement existing assays for eye phenotypes, and increase the accuracy of studies that use fly eyes for functional evaluation of genes and genetic interactions. PMID:26994292

  4. Assessment of tear osmolarity and other dry eye parameters in post-LASIK eyes.

    PubMed

    Hassan, Ziad; Szalai, Eszter; Berta, Andras; Modis, Laszlo; Nemeth, Gabor

    2013-07-01

    To assess the tear osmolarity using the TearLab device after laser in situ keratomileusis (LASIK) and to compare the values with those obtained by traditional tear film tests before and after the procedure. Thirty eyes of 15 refractive surgery candidates (5 men and 10 women of mean age: 30.55 ± 11.79 years) were examined. Using a special questionnaire (Ocular Surface Disease Index), subjective dry eye complaints were evaluated, and then, the tear osmolarity was measured with the TearLab system (TearLab Corporation) and conventional dry eye tests were carried out. Examinations were performed preoperatively and at 1, 30, and 60 days after the surgery. The mean value of tear osmolarity was 303.62 ± 12.29 mOsm/L before the surgery and 303.58 ± 20.14 mOsm/L at 60 days after the treatment (P = 0.69). Mean lid parallel conjunctival folds value was 0.68 ± 0.68 before the procedure and 0.58 ± 0.65 subsequent to surgery (P = 0.25). Meibomian gland dysfunction was not detected. No significant deviation was observed in the values of Schirmer test, corneal staining, tear break-up time, and lid parallel conjunctival folds when compared with postoperatively obtained values during the follow-up period (P > 0.05). During LASIK flap creation, intact corneal innervation is damaged, and the ocular surface lacrimal functional unit can be impaired. In our study, no abnormal dry eye test results were observed before or after the procedure. Based on our results, LASIK treatment is safe for dry eye involving the administration of adequate artificial tears for a minimum of 3 months.

  5. [Analysis of an ophthalmic pathology cohort of human fetal eyes with regard to interesting findings].

    PubMed

    Herwig, M C; Müller, A M; Holz, F G; Loeffler, K U

    2010-11-01

    Information on the evaluation of prenatal ocular findings is sparse. This article provides an overview of the morphology in a cohort of human fetal eyes, with particular emphasis on interesting findings. The study investigated 216 eyes from 115 human fetuses. The majority of fetal eyes presented with a regular phenotype. Rarely, unexpected findings were discovered in fetuses with or without systemic malformations. Routine evaluation of fetal eyes reveals-albeit rarely-new aspects providing further knowledge and occasionally enabling the exact classification of syndromes.

  6. Evaluation of helmet-mounted display targeting symbology based on eye tracking technology

    NASA Astrophysics Data System (ADS)

    Wang, Lijing; Wen, Fuzhen; Ma, Caixin; Zhao, Shengchu; Liu, Xiaodong

    2014-06-01

    The purpose of this paper is to find the Target Locator Lines (TLLs) which perform best by contrasting and comparing experiment based on three kinds of TTLs of fighter HMD. 10 university students, male, with an average age of 21-23, corrected visual acuity 1.5, participated in the experiment. In the experiment, head movement data was obtained by TrackIR. The geometric relationship between the coordinates of the real world and coordinates of the visual display was obtained by calculating the distance from viewpoint to midpoint of both eyes and the head movement data. Virtual helmet system simulation experiment environment was created by drawing TLLs of fighter HMD in the flight simulator visual scene. In the experiment, eye tracker was used to record the time and saccade trajectory. The results were evaluated by the duration of the time and saccade trajectory. The results showed that the symbol"locator line with digital vector length indication" cost most time and had the longest length of the saccade trajectory. It is the most ineffective and most unacceptable way. "Locator line with extending head vector length symbol" cost less time and had less length of the saccade trajectory. It is effective and acceptable;"Locator line with reflected vector length symbol" cost the least time and had the least length of the saccade trajectory. It is the most effective and most acceptable way. "Locator line with reflected vector length symbol" performs best. The results will provide reference value for the research of TTLs in future.

  7. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes.

    PubMed

    Mao, Xinjie; Banta, James T; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye.

  8. Treatment of Sjögren's syndrome dry eye using 0.03% tacrolimus eye drop: Prospective double-blind randomized study.

    PubMed

    Moscovici, Bernardo Kaplan; Holzchuh, Ricardo; Sakassegawa-Naves, Fernando Eiji; Hoshino-Ruiz, Diego Ricardo; Albers, Marcos Bottene Villa; Santo, Ruth Miyuki; Hida, Richard Yudi

    2015-10-01

    To describe the clinical efficacy of the treatment of Sjögren's syndrome dry eye using 0.03% tacrolimus eye drop. Prospective double-blind randomized study. Institutional outpatient clinic. Forty-eight eyes of twenty-four patients with dry eye related to Sjögren syndrome were enrolled in this study. The patients were randomized in 2 groups: tacrolimus (n=14) and vehicle (n=10) group. The tacrolimus group received a vial containing tacrolimus 0.03% (almond oil as vehicle) and the other group received the almond oil vehicle. All patients were instructed to use the eye drops every 12h in the lower conjunctival sac. Schirmer I test, break-up-time (BUT), corneal fluorescein and Rose Bengal staining scores were evaluated in all patients one day before the treatment (baseline), 7, 14, 28 and 90 days after treatment with the eye drops. The average fluorescein and Rose Bengal scores improved statistically after 7 days of treatment and even more after 90 days. The average Schirmer I and BUT values were unchanged after 7, 14 and 21 days but did show an improvement relative to baseline after 28 days of treatment. Schirmer I, BUT, fluorescein and Rose Bengal did not show any statistical significance in the vehicle group. Topical 0.03% tacrolimus eye drop improved tear stability and ocular surface status in cases of inflammatory or SS-related dry eye. ClinicalTrials.gov Identifier: NCT01850979. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  9. Fungal Eye Infections

    MedlinePlus

    ... fungal eye infections . Fungal eye infections are extremely rare, but they can be very serious. The most common way for someone to develop a fungal eye infection is as a result of an eye injury, particularly if the injury was caused by plant material such as a stick or a thorn. ...

  10. Anisocoria Secondary to Anticholinergic Mydriasis from Homeopathic Pink Eye Relief Drops.

    PubMed

    Chen, Lin; Yeung, Joseph C; Anderson, Dennis R

    2017-12-01

    A woman, aged 70 years, developed anisocoria after applying homeopathic eye drops (Similasan Pink Eye Relief) to her left eye. Her pupil was dilated for two weeks and did not respond to light or near stimuli for one week. Both 0.1% and 1% pilocarpine failed to constrict her left pupil, and magnetic resonance imaging of her brain did not reveal any abnormality. The eye drops she had used contain belladonna extracts which have a natural atropine component. This case demonstrates the importance, when evaluating a patient presenting with anisocoria, of knowing the chemical ingredients of the homeopathic eye drops, which often are not listed. © 2017 Marshfield Clinic.

  11. Transplantation of BDNF-Secreting Mesenchymal Stem Cells Provides Neuroprotection in Chronically Hypertensive Rat Eyes

    PubMed Central

    Harper, Matthew M.; Grozdanic, Sinisa D.; Blits, Bas; Kuehn, Markus H.; Zamzow, Daniel; Buss, Janice E.; Kardon, Randy H.; Sakaguchi, Donald S.

    2011-01-01

    Purpose. To evaluate the ability of mesenchymal stem cells (MSCs) engineered to produce and secrete brain-derived neurotrophic factor (BDNF) to protect retinal function and structure after intravitreal transplantation in a rat model of chronic ocular hypertension (COH). Methods. COH was induced by laser cauterization of trabecular meshwork and episcleral veins in rat eyes. COH eyes received an intravitreal transplant of MSCs engineered to express BDNF and green fluorescent protein (BDNF-MSCs) or just GFP (GFP-MSCs). Computerized pupillometry and electroretinography (ERG) were performed to assess optic nerve and retinal function. Quantification of optic nerve damage was performed by counting retinal ganglion cells (RGCs) and evaluating optic nerve cross-sections. Results. After transplantation into COH eyes, BDNF-MSCs preserved significantly more retina and optic nerve function than GFP-MSC–treated eyes when pupil light reflex (PLR) and ERG function were evaluated. PLR analysis showed significantly better function (P = 0.03) in BDNF-MSC–treated eyes (operated/control ratio = 63.00% ± 11.39%) than GFP-MSC–treated eyes (operated/control ratio = 31.81% ± 9.63%) at 42 days after surgery. The BDNF-MSC–transplanted eyes also displayed a greater level of RGC preservation than eyes that received the GFP-MSCs only (RGC cell counts: BDNF-MSC–treated COH eyes, 112.2 ± 19.39 cells/section; GFP-MSC–treated COH eyes, 52.21 ± 11.54 cells/section; P = 0.01). Conclusions. The authors have demonstrated that lentiviral-transduced BDNF-producing MSCs can survive in eyes with chronic hypertension and can provide retina and optic nerve functional and structural protection. Transplantation of BDNF-producing stem cells may be a viable treatment strategy for glaucoma. PMID:21498611

  12. Dose estimation of eye lens for interventional procedures in diagnosis

    NASA Astrophysics Data System (ADS)

    Liu, Yu-Rong; Huang, Chia-Yu; Hsu, Ching-Han; Hsu, Fang-Yuh

    2017-11-01

    The International Commission on Radiological Protection (ICRP) recommended that the equivalent dose limit for the lens of the eye be decreased from 150 mSv/y (ICRP, 2007) to 20 mSv/y averaged over five years (ICRP, 2011). How to accurately measure the eye-lens dose has, therefore, been an issue of interest recently. Interventional radiologists are at a higher risk of radiation-induced eye injury, such as cataracts, than all other occupational radiation workers. The main objective of this study is to investigate the relationship between the doses to the eye lenses of interventional radiologists measured by different commercial eye-lens dosimeters. This study measured a reference eye-lens dose, which involved placing thermoluminescent dosimeter (TLD) chips at the surface of the eye of the Rando Phantom, and the TLD chips were covered by a 3-mm-thick tissue-equivalent bolus. Commercial eye-lens dosimeters, such as a headband dosimeter and standard personnel dose badges, were placed at the positions recommended by the manufacturers. The results show that the personnel dose badge is not an appropriate dosimeter for evaluating eye-lens dose. Dose deviations for different dosimeters are discussed and presented in this study.

  13. Trajectory prediction of saccadic eye movements using a compressed exponential model

    PubMed Central

    Han, Peng; Saunders, Daniel R.; Woods, Russell L.; Luo, Gang

    2013-01-01

    Gaze-contingent display paradigms play an important role in vision research. The time delay due to data transmission from eye tracker to monitor may lead to a misalignment between the gaze direction and image manipulation during eye movements, and therefore compromise the contingency. We present a method to reduce this misalignment by using a compressed exponential function to model the trajectories of saccadic eye movements. Our algorithm was evaluated using experimental data from 1,212 saccades ranging from 3° to 30°, which were collected with an EyeLink 1000 and a Dual-Purkinje Image (DPI) eye tracker. The model fits eye displacement with a high agreement (R2 > 0.96). When assuming a 10-millisecond time delay, prediction of 2D saccade trajectories using our model could reduce the misalignment by 30% to 60% with the EyeLink tracker and 20% to 40% with the DPI tracker for saccades larger than 8°. Because a certain number of samples are required for model fitting, the prediction did not offer improvement for most small saccades and the early stages of large saccades. Evaluation was also performed for a simulated 100-Hz gaze-contingent display using the prerecorded saccade data. With prediction, the percentage of misalignment larger than 2° dropped from 45% to 20% for EyeLink and 42% to 26% for DPI data. These results suggest that the saccade-prediction algorithm may help create more accurate gaze-contingent displays. PMID:23902753

  14. Cortexin diffusion in human eye sclera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Genina, Elina A; Bashkatov, A N; Tuchin, Valerii V

    2011-05-31

    Investigation of the diffusion of cytamines, a typical representative of which is cortexin, is important for evaluating the drug dose, necessary to provide sufficient concentration of the preparation in the inner tissues of the eye. In the present paper, the cortexin diffusion rate in the eye sclera is measured using the methods of optical coherence tomography (OCT) and reflectance spectroscopy. The technique for determining the diffusion coefficient is based on the registration of temporal dependence of the eye sclera scattering parameters caused by partial replacement of interstitial fluid with the aqueous cortexin solution, which reduces the level of the OCTmore » signal and decreases the reflectance of the sclera. The values of the cortexin diffusion coefficient obtained using two independent optical methods are in good agreement. (optical technologies in biophysics and medicine)« less

  15. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma.

    PubMed

    Kasneci, Enkelejda; Black, Alex A; Wood, Joanne M

    2017-01-01

    To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior.

  16. Eye-Tracking as a Tool to Evaluate Functional Ability in Everyday Tasks in Glaucoma

    PubMed Central

    Black, Alex A.

    2017-01-01

    To date, few studies have investigated the eye movement patterns of individuals with glaucoma while they undertake everyday tasks in real-world settings. While some of these studies have reported possible compensatory gaze patterns in those with glaucoma who demonstrated good task performance despite their visual field loss, little is known about the complex interaction between field loss and visual scanning strategies and the impact on task performance and, consequently, on quality of life. We review existing approaches that have quantified the effect of glaucomatous visual field defects on the ability to undertake everyday activities through the use of eye movement analysis. Furthermore, we discuss current developments in eye-tracking technology and the potential for combining eye-tracking with virtual reality and advanced analytical approaches. Recent technological developments suggest that systems based on eye-tracking have the potential to assist individuals with glaucomatous loss to maintain or even improve their performance on everyday tasks and hence enhance their long-term quality of life. We discuss novel approaches for studying the visual search behavior of individuals with glaucoma that have the potential to assist individuals with glaucoma, through the use of personalized programs that take into consideration the individual characteristics of their remaining visual field and visual search behavior. PMID:28293433

  17. Clinical evaluation of pazopanib eye drops versus ranibizumab intravitreal injections in subjects with neovascular age-related macular degeneration.

    PubMed

    Csaky, Karl G; Dugel, Pravin U; Pierce, Amy J; Fries, Michael A; Kelly, Deborah S; Danis, Ronald P; Wurzelmann, John I; Xu, Chun-Fang; Hossain, Mohammad; Trivedi, Trupti

    2015-03-01

    To evaluate pazopanib eye drops in subjects with active subfoveal choroidal neovascularization (CNV) secondary to age-related macular degeneration (AMD). Multicountry, randomized, parallel-group, double-masked, active and placebo-controlled, dose-ranging study of eye drops. A total of 510 subjects (93% white; 58% female; mean age, 75.3 years) whose AMD was previously managed by anti-vascular endothelial growth factor intravitreal injections. Treatments administered for 52 weeks included placebo eye drops instilled 4 times daily (n=73); pazopanib 5 mg/ml instilled 3 (n=72) or 4 times daily (n=74); pazopanib 10 mg/ml instilled 2 (n=73), 3 (n=73), or 4 times daily (n=72); or ranibizumab injection administered once every 4 weeks (n=73). In addition, for all eye drop treatment groups, open-label ranibizumab was administered as needed. The main outcome measures were best-corrected visual acuity (BCVA) and injection frequency assessed at week 52. Safety was assessed every 4 weeks and pazopanib plasma concentrations were determined at weeks 4 and 24. At week 52, pazopanib, with allowance for as-needed ranibizumab injections, was noninferior to monthly ranibizumab as well as to as-needed ranibizumab administered with placebo eye drops in maintaining BCVA (estimated BCVA gains of 0.3-1.8 vs. 1.4 vs. 0.2 letters, respectively). Pazopanib treatment did not reduce as-needed ranibizumab injections by ≥50% (prespecified efficacy criterion). At week 52, there were no clinically meaningful changes from baseline in retinal thickness or morphology, CNV size, or lesion characteristics on optical coherence tomography or fluorescein angiography. Complement factor H genotype had no effect on the responses to pazopanib and/or ranibizumab (BCVA, injection rate, or optical coherence tomography/fluorescein angiography changes). Steady-state concentrations of pazopanib in plasma seemed to be reached by week 4. The most common ocular adverse events related to pazopanib and ranibizumab were

  18. Evaluating Fault Management Operations Concepts for Next-Generation Spacecraft: What Eye Movements Tell Us

    NASA Technical Reports Server (NTRS)

    Hayashi, Miwa; Ravinder, Ujwala; McCann, Robert S.; Beutter, Brent; Spirkovska, Lily

    2009-01-01

    Performance enhancements associated with selected forms of automation were quantified in a recent human-in-the-loop evaluation of two candidate operational concepts for fault management on next-generation spacecraft. The baseline concept, called Elsie, featured a full-suite of "soft" fault management interfaces. However, operators were forced to diagnose malfunctions with minimal assistance from the standalone caution and warning system. The other concept, called Besi, incorporated a more capable C&W system with an automated fault diagnosis capability. Results from analyses of participants' eye movements indicate that the greatest empirical benefit of the automation stemmed from eliminating the need for text processing on cluttered, text-rich displays.

  19. Prevalence and phenomenology of eye tics in Gilles de la Tourette syndrome.

    PubMed

    Martino, Davide; Cavanna, Andrea E; Robertson, Mary M; Orth, Michael

    2012-10-01

    Eye tics seem to be common in Gilles de la Tourette syndrome (GTS). We analyzed the frequency and clinical characteristics of eye tics in 212 GTS patients. Of the 212 patients, 201 (94.8 %) reported eye tics in their life-time; 166 (78.3 %) reported eye movement tics (rolling eyes up/down, eyes looking sideways, staring), and 194 (91.5 %) eyelid/eyebrow movement tics (frowning, raising eyebrows, blinking or winking). Patients with eye movement tics were younger at age of GTS onset (7.1 ± 4 years) than those without (8.9 ± 6.8; p = 0.024). Tic severity positively correlated to lifetime history of eye and/or eyelid/eyebrow movement tics. Our data confirm that eye and eyelid/eyebrow movement tics are very common in GTS, and most patients have several types of eye tics over time. Eye tic phenomenology was similar in patients with or without co-morbidity. Eye tics are therefore likely to be a core feature of GTS and should be routinely evaluated in order to strengthen the clinician's confidence in diagnosing GTS.

  20. Apoptosis of conjunctival epithelial cells before and after the application of autologous serum eye drops in severe dry eye disease.

    PubMed

    Rybickova, Ivana; Vesela, Viera; Fales, Ivan; Skalicka, Pavlina; Jirsova, Katerina

    2016-06-01

    To assess the impact of autologous serum eye drops on the level of ocular surface apoptosis in patients with bilateral severe dry eye disease. This prospective study was conducted on 10 patients with severe dry eye due to graft versus host disease (group 1) and 6 patients with severe dry eye due to primary Sjögren's syndrome (group 2). Impression cytology specimens from the bulbar conjunctiva were obtained before and after a three-month treatment with 20% autologous serum eye drops applied a maximum of 12 times a day together with regular therapy with artificial tears. The percentage of apoptotic epithelial cells was evaluated immunochemically using anti-active caspase 3 antibody. In group 1, the mean percentage of apoptotic cells was 3.6% before the treatment. The three-month treatment led to a significant decrease to a mean percentage of 1.8% (P = 0.028). The mean percentage of apoptotic conjunctival cells decreased from 5.4% before the treatment to 3.8% in group 2; however, these results did not reach the level of significance. Three-month autologous serum treatment led to the improvement of ocular surface apoptosis, especially in the group of patients with severe dry eye due to graft versus host disease. This result supports the very positive effect of autologous serum on the ocular surface in patients suffering from severe dry eye.

  1. Evaluating Silent Reading Performance with an Eye Tracking System in Patients with Glaucoma

    PubMed Central

    Murata, Noriaki; Fukuchi, Takeo

    2017-01-01

    Objective To investigate the relationship between silent reading performance and visual field defects in patients with glaucoma using an eye tracking system. Methods Fifty glaucoma patients (Group G; mean age, 52.2 years, standard deviation: 11.4 years) and 20 normal controls (Group N; mean age, 46.9 years; standard deviation: 17.2 years) were included in the study. All participants in Group G had early to advanced glaucomatous visual field defects but better than 20/20 visual acuity in both eyes. Participants silently read Japanese articles written horizontally while the eye tracking system monitored and calculated reading duration per 100 characters, number of fixations per 100 characters, and mean fixation duration, which were compared with mean deviation and visual field index values from Humphrey visual field testing (24–2 and 10–2 Swedish interactive threshold algorithm standard) of the right versus left eye and the better versus worse eye. Results There was a statistically significant difference between Groups G and N in mean fixation duration (G, 233.4 msec; N, 215.7 msec; P = 0.010). Within Group G, significant correlations were observed between reading duration and 24–2 right mean deviation (rs = -0.280, P = 0.049), 24–2 right visual field index (rs = -0.306, P = 0.030), 24–2 worse visual field index (rs = -0.304, P = 0.032), and 10–2 worse mean deviation (rs = -0.326, P = 0.025). Significant correlations were observed between mean fixation duration and 10–2 left mean deviation (rs = -0.294, P = 0.045) and 10–2 worse mean deviation (rs = -0.306, P = 0.037), respectively. Conclusions The severity of visual field defects may influence some aspects of reading performance. At least concerning silent reading, the visual field of the worse eye is an essential element of smoothness of reading. PMID:28095478

  2. [Evaluation of the arterial blood flow parameters in the eye of myopic patients].

    PubMed

    Mrugacz, Małgorzata; Bryl, Anna

    2013-04-01

    Myopia is a common refractive defect. Has a good vision from near and deterioration of vision with increasing distance. The main reason for its occurrence is too long axis of the eyeball. The consequence of elongation of the eyeball is the development of degenerative changes in the retina. Despite much research has failed to clearly identify the causes of degenerative changes in those short-sighted. The aim of the study was to evaluate the maximum and minimum speed in arterial blood vessels of the eye in people with myopia. The study included 70 patients (138 eyes), 53 women and 17 men, aged from 18 to 79 years, with myopia of -0.25 to -18.0 Dsph and length of the eyeball from 22.61 to 33.36 mm. Depending on the kind and the degree of the progress of degenerative changes, patients were divided in 4 groups: I - without degenerative changes on the fundus (n=32; K-23, M-9); II- with the short-sighted sickle (n=20; K-14, M-6); Ill - with the structure thinned down of the retina, accompanying the short-sighted sickle (n = 8; K-6, M-2); IV - with extensive choroidal-retina disappearances in the fundus (n = 10; K-7, M-3). In all individuals enrolled underwent Color Doppler ultrasound with apparatus SSA 770A Toshiba Aplio with linear probe frequency 12 MHz, judging maximum (Vmax) and minimum (Vmin) speed in the arteries of the eye: ophthalmic artery (OA), central retinal artery (CRA) and short posterior ciliary arteries (SPCA) located on the nasal and temporal side of the optic disc. The results were statistically analyzed. No statistically significant relationship between the nature of degenerative changes of the eye, and blood velocity in the OA. There was a increase in Vmax and Vmin blood in OA in Group IV, but these changes were not statistically significant. Statistically significant correlation was observed while in the CRA. With a decrease in Vmax and Vmin of blood flowing through a vessel exacerbation of retinal degeneration. Vmax and Vmin changes in the blood did

  3. Wavefront Derived Refraction and Full Eye Biometry in Pseudophakic Eyes

    PubMed Central

    Mao, Xinjie; Banta, James T.; Ke, Bilian; Jiang, Hong; He, Jichang; Liu, Che; Wang, Jianhua

    2016-01-01

    Purpose To assess wavefront derived refraction and full eye biometry including ciliary muscle dimension and full eye axial geometry in pseudophakic eyes using spectral domain OCT equipped with a Shack-Hartmann wavefront sensor. Methods Twenty-eight adult subjects (32 pseudophakic eyes) having recently undergone cataract surgery were enrolled in this study. A custom system combining two optical coherence tomography systems with a Shack-Hartmann wavefront sensor was constructed to image and monitor changes in whole eye biometry, the ciliary muscle and ocular aberration in the pseudophakic eye. A Badal optical channel and a visual target aligning with the wavefront sensor were incorporated into the system for measuring the wavefront-derived refraction. The imaging acquisition was performed twice. The coefficients of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated. Results Images were acquired and processed successfully in all patients. No significant difference was detected between repeated measurements of ciliary muscle dimension, full-eye biometry or defocus aberration. The CoR of full-eye biometry ranged from 0.36% to 3.04% and the ICC ranged from 0.981 to 0.999. The CoR for ciliary muscle dimensions ranged from 12.2% to 41.6% and the ICC ranged from 0.767 to 0.919. The defocus aberrations of the two measurements were 0.443 ± 0.534 D and 0.447 ± 0.586 D and the ICC was 0.951. Conclusions The combined system is capable of measuring full eye biometry and refraction with good repeatability. The system is suitable for future investigation of pseudoaccommodation in the pseudophakic eye. PMID:27010674

  4. Inadvertent Evisceration of Eyes Containing Uveal Melanoma

    PubMed Central

    Eagle, Ralph C.; Grossniklaus, Hans E.; Syed, Nasreen; Hogan, R. Nick; Lloyd, William C.; Folberg, Robert

    2010-01-01

    Objectives To report an important complication of ocular evisceration therapy for blind, painful eyes that has been unreported in the literature, and to stress the need for careful preoperative evaluation to exclude occult neoplasms prior to therapy. Design Multicenter, retrospective, nonrandomized clinicopathological case series of patients found to have previously unsuspected uveal malignant melanoma during histopathological examination of blind, painful eyes treated by evisceration. Results Histopathological examination of evisceration specimens disclosed previously unsuspected uveal melanoma in 7 patients who were treated for blind, painful eyes. Inflammation caused by necrosis of the tumor and other ocular tissues led to misdiagnosis as endophthalmitis, orbital cellulitis, or idiopathic orbital inflammation in several cases. Preoperative imaging was not performed in 3 cases and failed to detect tumors in the remaining 4 cases. Failure of necrotic tumors to enhance contributed to misdiagnosis. Conclusions The presence of a malignant intraocular neoplasm should be excluded prior to evisceration of any blind eye or blind, painful eye, particularly with opaque media. Necrosis-related inflammation can confound the clinical diagnosis of occult lesions, as can failure of necrotic tumors to enhance on imaging studies. PMID:19204229

  5. The role of eye protection in work-related eye injuries.

    PubMed

    Fong, L P; Taouk, Y

    1995-05-01

    A recent survey of general hospitals by the Victorian Injury Surveillance System found that ocular trauma represented 15% of work-related injuries. As circumstances surrounding occupational eye injuries have been poorly documented previously, their associations to occupation, industry and work-safety practices, including safety eyewear use, need to be identified to develop appropriate preventive strategies for high-risk groups. From a prospective cross-sectional survey of all eye injuries treated at the Royal Victorian Eye and Ear Hospital, work-related cases were analysed for demographic, occupational and safety eye-wear information. Hospital-based data were supplemented by information from WorkCover Authorities and Labour Force statistics to derive incidence and cost estimates. There were 9390 eye injuries during the 18-month survey period; 42% (n=3923) of total and 29% (n=52) of penetrating ocular injuries occurred at work. The most frequently injured were metal, automotive and building trades workers grinding and drilling (41% of outpatients) and hammering (53% of penetrating eye injuries). Automotive workers had the highest frequency for penetrating injuries, and most were exposed to hammering and were also the least likely to wear safety eye-wear. Eye injuries are frequent (10% of work-related injuries) and highly preventable by the correct use of safety eye-wear, a cost-effective intervention that may result in cost savings of $59 million for work-type activities in the occupational and domestic settings in Australia each year.

  6. Imaging shear stress distribution and evaluating the stress concentration factor of the human eye

    NASA Astrophysics Data System (ADS)

    Joseph Antony, S.

    2015-03-01

    Healthy eyes are vital for a better quality of human life. Historically, for man-made materials, scientists and engineers use stress concentration factors to characterise the effects of structural non-homogeneities on their mechanical strength. However, such information is scarce for the human eye. Here we present the shear stress distribution profiles of a healthy human cornea surface in vivo using photo-stress analysis tomography, which is a non-intrusive and non-X-ray based method. The corneal birefringent retardation measured here is comparable to that of previous studies. Using this, we derive eye stress concentration factors and the directional alignment of major principal stress on the surface of the cornea. Similar to thermometers being used for monitoring the general health in humans, this report provides a foundation to characterise the shear stress carrying capacity of the cornea, and a potential bench mark for validating theoretical modelling of stresses in the human eye in future.

  7. Evaluation of corrective reconstruction methods using a 3D cardiac-torso phantom and bull's-eye plots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, X.D.; Tsui, B.M.W.; Gregoriou, G.K.

    The goal of the investigation was to study the effectiveness of the corrective reconstruction methods in cardiac SPECT using a realistic phantom and to qualitatively and quantitatively evaluate the reconstructed images using bull's-eye plots. A 3D mathematical phantom which realistically models the anatomical structures of the cardiac-torso region of patients was used. The phantom allows simulation of both the attenuation distribution and the uptake of radiopharmaceuticals in different organs. Also, the phantom can be easily modified to simulate different genders and variations in patient anatomy. Two-dimensional projection data were generated from the phantom and included the effects of attenuation andmore » detector response blurring. The reconstruction methods used in the study included the conventional filtered backprojection (FBP) with no attenuation compensation, and the first-order Chang algorithm, an iterative filtered backprojection algorithm (IFBP), the weighted least square conjugate gradient algorithm and the ML-EM algorithm with non-uniform attenuation compensation. The transaxial reconstructed images were rearranged into short-axis slices from which bull's-eye plots of the count density distribution in the myocardium were generated.« less

  8. Advancements in anti-inflammatory therapy for dry eye syndrome.

    PubMed

    McCabe, Erin; Narayanan, Srihari

    2009-10-01

    The goal of this literature review is to discuss recent discoveries in the pathophysiology of dry eye and the subsequent evolution of diagnostic and management techniques. The mechanisms of various anti-inflammatory treatments are reviewed, and the efficacy of common pharmacologic agents is assessed. Anti-inflammatory therapy is evaluated in terms of its primary indications, target population, and utility within a clinical setting. The Medline PubMed database and the World Wide Web were searched for current information regarding dry eye prevalence, pathogenesis, diagnosis, and management. After an analysis of the literature, major concepts were integrated to generate an updated portrayal of the status of dry eye syndrome. Inflammation appears to play a key role in perpetuating and sustaining dry eye. Discoveries of inflammatory markers found within the corneal and conjunctival epithelium of dry eye patients have triggered recent advancements in therapy. Pharmacologic anti-inflammatory therapy for dry eye includes 2 major categories: corticosteroids and immunomodulatory agents. Fatty acid and androgen supplementation and oral antibiotics have also shown promise in dry eye therapy because of their anti-inflammatory effects. Anti-inflammatory pharmacologic agents have shown great success in patients with moderate to severe dry eye when compared with alternative treatment modalities. A deeper understanding of the link between inflammation and dry eye validates the utilization of anti-inflammatory therapy in everyday optometric practice.

  9. Evaluation of a New Scoring System for Retinal Nerve Fiber Layer Photography Using HRA1 in 964 Eyes

    PubMed Central

    Hong, Samin; Moon, Jong Wook; Ha, Seung Joo; Kim, Chan Yun; Seong, Gong Je

    2007-01-01

    Purpose To evaluate retinal nerve fiber layer (RNFL) defect by a new scoring system for RNFL photography using the Heidelberg Retina Angiograph 1 (HRA1). Methods This retrospective study included 128 healthy eyes and 836 primary open-angle glaucoma eyes. The RNFL photography using HRA1 was interpreted using a new scoring system, and correlated with visual field indices of standard automated perimetry (SAP). Using the presence of RNFL defect, darkness, width, and location, we established the new scoring system of RNFL photos. Results The mean RNFL defect score I in the early, moderate, severe, and control groups were 7.3, 9.2, 10.4, and 3.6, respectively. The mean RNFL defect score II in the early, moderate, severe, and control groups were 14.5, 28.5, 43.4, and 3.4, respectively. Correlations between the RNFL defect score II and the mean deviation of SAP was the strongest of the various combinations (r=-0.675, P<.001). Conclusions Using a new scoring system, we propose a method for semi-quantitative interpretation of RNFL photographs. This scoring system may be helpful to distinguish between normal and glaucomatous eyes, and the score is associated with the severity of visual field loss. PMID:18063886

  10. Quality control evaluation of Keshamasi, Keshanjana and Keshamasi eye ointment.

    PubMed

    Dhiman, Kartar Singh; Shukla, Vinay J; Bhalodia, Nayan R; Sharma, Vinay R

    2014-01-01

    Keshanjana (collyrium) is a well known Ayurvedic preparation prepared out of Keshamasi (ash prepared by scalp hairs) mixed with Goghrita (cow's ghee). This medicine is indicated for the treatment of Shushkakshipaka (dry eye syndrome) in the classical literature of Ayurveda; hence, it was under taken for standardization and clinical evaluation in an extra-mural research project from Central Council for Research in Ayurvedic Sciences, Department of AYUSH, New Delhi. To develop standard quality parameters for the Keshamasi, Keshanjana and Keshamasi ointment. Scalp hairs of male and females collected from saloons were converted to classical Masi Kalpana and mixed with cow ghee and petrolatum in the ratio of 1:5 to prepare the Keshanjana and Keshamasi ointment respectively. Standard Operation Procedure (SOP) were adopted and recorded accordingly. The raw material, furnished products and plain Goghrita were subjected for quality control parameters i.e., physico-chemical evaluation, anti-microbial study, particle size analysis, heavy metal analysis through inductive couple plasma spectroscopy with high performance thin layer liquid chromatography fingerprints. Rancidity was negative in all the samples, indicating that the physico-chemical parameters are in acceptable range. Lead and zinc were present in most of the samples; while all samples are were free from microbial contamination. As no standards are available to compare the results of the current study, the observations cannot be compared. Thus the profile generated in the current study can be considered as standard to refer in future studies.

  11. 38 CFR 4.79 - Schedule of ratings-eye.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... retina. 6009Unhealed eye injury. General Rating Formula for Diagnostic Codes 6000 through 6009 Evaluate... irregularities, if this would result in a higher evaluation. 6012Angle-closure glaucoma: Evaluate on the basis of either visual impairment due to angle-closure glaucoma or incapacitating episodes, whichever results in a...

  12. 38 CFR 4.79 - Schedule of ratings-eye.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... retina. 6009Unhealed eye injury. General Rating Formula for Diagnostic Codes 6000 through 6009 Evaluate... irregularities, if this would result in a higher evaluation. 6012Angle-closure glaucoma: Evaluate on the basis of either visual impairment due to angle-closure glaucoma or incapacitating episodes, whichever results in a...

  13. 38 CFR 4.79 - Schedule of ratings-eye.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... retina. 6009Unhealed eye injury. General Rating Formula for Diagnostic Codes 6000 through 6009 Evaluate... irregularities, if this would result in a higher evaluation. 6012Angle-closure glaucoma: Evaluate on the basis of either visual impairment due to angle-closure glaucoma or incapacitating episodes, whichever results in a...

  14. Double-pass measurement of human eye aberrations: limitations and practical realization

    NASA Astrophysics Data System (ADS)

    Letfullin, Renat R.; Belyakov, Alexey I.; Cherezova, Tatyana Y.; Kudryashov, Alexis V.

    2004-11-01

    The problem of correct eye aberrations measurement is very important with the rising widespread of a surgical procedure for reducing refractive error in the eye, so called, LASIK (laser-assisted in situ keratomileusis). The double-pass technique commonly used for measuring aberrations of a human eye involves some uncertainties. One of them is loosing the information about odd human eye aberrations. We report about investigations of the applicability limit of the double-pass measurements depending upon the aberrations status introduced by human eye and actual size of the entrance pupil. We evaluate the double-pass effects for various aberrations and different pupil diameters. It is shown that for small pupils the double-pass effects are negligible. The testing and alignment of aberrometer was performed using the schematic eye, developed in our lab. We also introduced a model of human eye based on bimorph flexible mirror. We perform calculations to demonstrate that our schematic eye is capable of reproducing spatial-temporal statistics of aberrations of living eye with normal vision or even myopic or hypermetropic or with high aberrations ones.

  15. Keeping an eye on pain: investigating visual attention biases in individuals with chronic pain using eye-tracking methodology

    PubMed Central

    Fashler, Samantha R; Katz, Joel

    2016-01-01

    Attentional biases to painful stimuli are evident in individuals with chronic pain, although the directional tendency of these biases (ie, toward or away from threat-related stimuli) remains unclear. This study used eye-tracking technology, a measure of visual attention, to evaluate the attentional patterns of individuals with and without chronic pain during exposure to injury-related and neutral pictures. Individuals with (N=51) and without chronic pain (N=62) completed a dot-probe task using injury-related and neutral pictures while their eye movements were recorded. Mixed-design analysis of variance evaluated the interaction between group (chronic pain, pain-free) and picture type (injury-related, neutral). Reaction time results showed that regardless of chronic pain status, participants responded faster to trials with neutral stimuli in comparison to trials that included injury-related pictures. Eye-tracking measures showed within-group differences whereby injury-related pictures received more frequent fixations and visits, as well as longer average visit durations. Between-group differences showed that individuals with chronic pain had fewer fixations and shorter average visit durations for all stimuli. An examination of how biases change over the time-course of stimulus presentation showed that during the late phase of attention, individuals with chronic pain had longer average gaze durations on injury pictures relative to pain-free individuals. The results show the advantage of incorporating eye-tracking methodology when examining attentional biases, and suggest future avenues of research. PMID:27570461

  16. Comparative Evaluation of the Corneal and Anterior Chamber Parameters Derived From Scheimpflug Imaging in Arab and South Asian Normal Eyes.

    PubMed

    Prakash, Gaurav; Srivastava, Dhruv; Avadhani, Kavitha; Thirumalai, Sandeep M; Choudhuri, Sounak

    2015-11-01

    To evaluate the differences in the normal corneal and anterior segment Scheimpflug parameters in Arab and South Asian eyes. This hospital-based study was performed at a cornea and refractive surgery service in Abu Dhabi. A total of 600 consecutive normal candidates of South Asian (group 1, n = 300) and Arab (group 2, n = 300) origins underwent Scheimpflug imaging (Sirius; Costruzione Strumenti Oftalmici, Italy). One eye was randomly selected for evaluation. The age and sex distributions in both groups were comparable. The pachymetric variables were statistically higher in group 2 (group 2 vs. group 1, 544.3 ± 32.2 μm vs. 535.1 ± 31.4 μm for central corneal thickness, 541.0 ± 32.6 μm vs. 531.9 ± 31.5 μm for minimum corneal thickness, 571.7 ± 43.2 μm vs. 558.1 ± 42.3 μm for apical thickness, and 58.1 ± 4.2 vs. 57.3 ± 4.3 mm³ for the corneal volume; P < 0.05). The anterior chamber volume (group 2 vs. group 1: 166.4 ± 16.4 vs. 161.6 ± 20.5 mm³) and angle (group 2 vs. group 1: 44.6 ± 6.2 vs. 43.5 ± 5.8 degrees) were also higher for group 2 (P < 0.05). Central corneal curvature and apical corneal curvature (apex K) were higher in group 1 (P < 0.05) with comparable astigmatism. The flat keratometry (K), steep K, and apex K were 43.6 ± 2.2 diopters (D), 44.9 ± 1.8 D, and 45.7 ± 1.8 D for group 1, and 43.1 ± 2.2 D, 44.5 ± 2 D, and 45.2 ± 1.9 D for group 2. The effect size (Cohen d) for significant parameters ranged from 0.2 to 0.3. Normal eyes of Arab ethnicity tend to have statistically thicker and flatter corneas and less-crowded anterior segments than those of the South Asian counterparts. These epidemiological differences have a mild to moderate biological effect size (Cohen d), but they should be considered when evaluating these eyes for anterior segment or corneal procedures.

  17. Premotor neurons encode torsional eye velocity during smooth-pursuit eye movements

    NASA Technical Reports Server (NTRS)

    Angelaki, Dora E.; Dickman, J. David

    2003-01-01

    Responses to horizontal and vertical ocular pursuit and head and body rotation in multiple planes were recorded in eye movement-sensitive neurons in the rostral vestibular nuclei (VN) of two rhesus monkeys. When tested during pursuit through primary eye position, the majority of the cells preferred either horizontal or vertical target motion. During pursuit of targets that moved horizontally at different vertical eccentricities or vertically at different horizontal eccentricities, eye angular velocity has been shown to include a torsional component the amplitude of which is proportional to half the gaze angle ("half-angle rule" of Listing's law). Approximately half of the neurons, the majority of which were characterized as "vertical" during pursuit through primary position, exhibited significant changes in their response gain and/or phase as a function of gaze eccentricity during pursuit, as if they were also sensitive to torsional eye velocity. Multiple linear regression analysis revealed a significant contribution of torsional eye movement sensitivity to the responsiveness of the cells. These findings suggest that many VN neurons encode three-dimensional angular velocity, rather than the two-dimensional derivative of eye position, during smooth-pursuit eye movements. Although no clear clustering of pursuit preferred-direction vectors along the semicircular canal axes was observed, the sensitivity of VN neurons to torsional eye movements might reflect a preservation of similar premotor coding of visual and vestibular-driven slow eye movements for both lateral-eyed and foveate species.

  18. A Multicenter Retrospective Survey of Refractive Surgery in 78,248 Eyes.

    PubMed

    Kamiya, Kazutaka; Igarashi, Akihito; Hayashi, Ken; Negishi, Kazuno; Sato, Masaki; Bissen-Miyajima, Hiroko

    2017-09-01

    To retrospectively evaluate the current practice, trends, and outcomes of refractive surgery in Japan. This multicenter survey comprised 78,248 eyes of 39,727 consecutive patients who underwent refractive surgery at 45 major institutions in Japan. The corresponding ophthalmologists responded to a selfadministered questionnaire. The authors especially evaluated the safety, efficacy, predictability, stability, and adverse events of LASIK and phakic intraocular lens (IOL) implantation 3 months postoperatively. The most common refractive surgery was LASIK (90.9%), followed by corneal inlay (5.0%), posterior chamber phakic IOL implantation (1.3%), laser-assisted subepithelial keratomileusis (1.0%), refractive lens exchange (0.9%), photorefractive keratectomy (0.3%), and refractive lenticule extraction (0.2%). For subgroup analysis, 69,987 eyes (99.5%) and 67,512 eyes (95.9%) achieved corrected and uncorrected distance visual acuity of 20/20 or better, respectively, after LASIK, and 935 eyes (98.8%) and 890 eyes (94.1%), respectively, after phakic IOL implantation. There were 69,176 eyes (98.3%) and 908 eyes (96.0%) within ±1.00 diopter (D) of the attempted correction after LASIK and phakic IOL implantation, respectively. There were 1,926 eyes (2.7%) and 1 eye (0.1%) with changes in refraction of 1.00 D or less from 1 week to 3 months after LASIK and phakic IOL implantation, respectively. No vision-threatening complications occurred in any case. According to this survey, LASIK remains the most prevalent surgical technique in Japan. Both LASIK and phakic IOL implantation offered good safety and efficacy outcomes, yielding predictable and stable results. [J Refract Surg. 2017;33(9):598-602.]. Copyright 2017, SLACK Incorporated.

  19. Evaluating a tablet application and differential reinforcement to increase eye contact in children with autism.

    PubMed

    Jeffries, Tricia; Crosland, Kimberly; Miltenberger, Raymond

    2016-03-01

    We tested the effectiveness of a tablet application and differential reinforcement to increase eye contact in 3 children with autism. The application required the child to look at a picture of a person's face and identify the number displayed in the person's eyes. Eye contact was assessed immediately after training, 1 hr after training, and in a playroom. The tablet application was not effective; however, differential reinforcement was effective for all participants. © 2015 Society for the Experimental Analysis of Behavior.

  20. Burning Eye Syndrome: Do Neuropathic Pain Mechanisms Underlie Chronic Dry Eye?

    PubMed

    Kalangara, Jerry P; Galor, Anat; Levitt, Roy C; Felix, Elizabeth R; Alegret, Ramon; Sarantopoulos, Constantine D

    2016-04-01

    Dry eye is a multi-factorial disorder that manifests with painful ocular symptoms and visual disturbances, which can only be partly attributed to tear dysfunction. This disorder may also involve neuroplasticity in response to neuronal injury. This review will emphasize the key characteristics of dry eye pain and its pathologic mechanisms, making the argument that a subset of dry eye represents a neuropathic pain disorder of the eye, more appropriately called "burning eye syndrome." A literature review was conducted using a PubMed search focusing on dry eye, corneal nociception, and neuropathic pain. Articles were reviewed and those discussing clinical course, pathophysiology, and neuronal regulation of chronic ocular pain as related to dry eye were summarized. We found that there is a discordance between ocular pain and dryness on the ocular surface. Although tear dysfunction may be one of the initial insults, its persistence may be associated with repeated ocular sensory nerve injury leading to an acute-to-chronic pain transition associated with neuropathologic changes (peripheral and central sensitization), neuronal dysfunction, and spontaneous ocular pain. Dry eye is becoming a major health concern due to its increasing incidence, significant morbidity, and economic burden. Recent evidence suggests that a subset of dry eye may be better represented as a chronic neuropathic pain disorder due to its features of dysesthesia, spontaneous pain, allodynia, and hyperalgesia. Future therapies targeted at the underlying neuroplasticity may yield improved efficacy for patients with this subset of dry eye, which we term "burning eye syndrome." © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. Fluorescein eye stain

    MedlinePlus

    Abnormal results may point to: Abnormal tear production (dry eye) Blocked tear duct Corneal abrasion (a scratch on ... object in eye ) Infection Injury or trauma Severe dry eye associated with arthritis (keratoconjunctivitis sicca)

  2. The perception of isoluminant coloured stimuli of amblyopic eye and defocused eye

    NASA Astrophysics Data System (ADS)

    Krumina, Gunta; Ozolinsh, Maris; Ikaunieks, Gatis

    2008-09-01

    In routine eye examination the visual acuity usually is determined using standard charts with black letters on a white background, however contrast and colour are important characteristics of visual perception. The purpose of research was to study the perception of isoluminant coloured stimuli in the cases of true and simulated amlyopia. We estimated difference in visual acuity with isoluminant coloured stimuli comparing to that for high contrast black-white stimuli for true amblyopia and simulated amblyopia. Tests were generated on computer screen. Visual acuity was detected using different charts in two ways: standard achromatic stimuli (black symbols on a white background) and isoluminant coloured stimuli (white symbols on a yellow background, grey symbols on blue, green or red background). Thus isoluminant tests had colour contrast only but had no luminance contrast. Visual acuity evaluated with the standard method and colour tests were studied for subjects with good visual acuity, if necessary using the best vision correction. The same was performed for subjects with defocused eye and with true amblyopia. Defocus was realized with optical lenses placed in front of the normal eye. The obtained results applying the isoluminant colour charts revealed worsening of the visual acuity comparing with the visual acuity estimated with a standard high contrast method (black symbols on a white background).

  3. [Randomly sampling survey of dry eye awareness in general eye clinic].

    PubMed

    Qiu, Wei-qiang; Liu, Zi-yuan; Ji, Jing; Zeng, Lin; Li, Xue-min; Wang, Wei

    2013-03-01

    To determine the dry eye awareness in the populations visiting general eye clinic. This was a cross-sectional study. A questionnaire about dry eye was designed and administrated to Peking University Third Hospital General Eye Clinic patients (n = 804) from June 2010 to June 2011. The questionnaire contents included general demographic characteristics, experience of health-related work, past medical history, medication history and ocular surface symptoms associated with dry eye, contact lens wearing, ocular operation history, etc. Chi-square and Binary logistic regression analysis was used to determine the influence of demographic and clinical features on awareness of dry eye. Awareness of "dry eye" in the general eye clinical patients was relatively low (26.9%, 216/804). Participants whose age were between 40 and 60 years had better dry eye awareness (41.7%, 73/175) (χ(2) = 27.365, P = 0.000). Dry eye awareness of female was better than that of male [female: 33.8% (151/447), male: 18.2% (65/357), χ(2) = 24.500, P = 0.000]. Those who had been in health-related work (71.4%, 30/42), and whose friends or relatives were ophthalmologists (54.7%, 52/95) had better dry eye awareness (χ(2) = 31.582, 36.400; both P < 0.01). Participants with a history of rheumatoid arthritis (7/10) or diabetes mellitus (63.0%, 17/27) had better dry eye awareness (χ(2) = 32.301, 29.887;both P < 0.01). Those who had been using artificial tears (77.5%, 31/40), oral contraceptives (9/14), diuretics (10/18), sedatives (70.4%, 19/27) and anti-depression drugs (4/4) had better dry eye awareness (χ(2) = 54.928, 10.154, 7.713, 26.912, 10.943; all P < 0.01). Except frequently blinking (29.5%), participants who had ocular irrigating symptoms (all > 33.0%) had better awareness than those who had not (χ(2) = 7.831 - 32.522, all P < 0.01). Those who were allergic to environment irritating factors (all > 30.0%) had better awareness (χ(2) = 5.033 - 24.564, all P < 0.01). Participants who had medical

  4. New eye phantom for ophthalmic surgery

    NASA Astrophysics Data System (ADS)

    Fogli, Gessica; Orsi, Gianni; De Maria, Carmelo; Montemurro, Francesca; Palla, Michele; Rizzo, Stanislao; Vozzi, Giovanni

    2014-06-01

    In this work, we designed and realized a new phantom able to mimic the principal mechanical, rheological, and physical cues of the human eye and that can be used as a common benchmark to validate new surgical procedures, innovative vitrectomes, and as a training system for surgeons. This phantom, in particular its synthetic humor vitreous, had the aim of reproducing diffusion properties of the natural eye and can be used as a system to evaluate the pharmacokinetics of drugs and optimization of their dose, limiting animal experiments. The eye phantom was built layer-by-layer starting from the sclera up to the retina, using low cost and easy to process polymers. The validation of the phantom was carried out by mechanical characterization of each layer, by diffusion test with commercial drugs into a purposely developed apparatus, and finally by a team of ophthalmic surgeons. Experiments demonstrated that polycaprolactone, polydimethylsiloxane, and gelatin, properly prepared, are the best materials to mimic the mechanical properties of sclera, choroid, and retina, respectively. A polyvinyl alcohol-gelatin polymeric system is the best for mimicking the viscosity of the human humor vitreous, even if the bevacizumab half-life is lower than in the human eye.

  5. A retrospective analysis of eye conditions among children attending St. John Eye Hospital, Hebron, Palestine.

    PubMed

    Banayot, Riyad G

    2016-04-05

    Eye diseases are important causes of medical consultations, with the spectrum varying in different regions. This hospital-based descriptive study aimed to determine the profile of childhood eye conditions at St. John tertiary Eye hospital serving in Hebron, Palestine. Files of all new patients less than 16 years old who presented to St. John Eye Hospital-Hebron, Palestine between January 2013 and December 2013 were retrospectively reviewed. Age at presentation, sex, and clinical diagnosis were extracted from medical records. Data were stored and analyzed using Wizard data analysis version 1.6.0 by Evan Miller. The Chi square test was used to compare variables and a p value of less than 0.05 was considered statistically significant. We evaluated the records of 1102 patients, with a female: male ratio of 1:1.1. Patients aged 0-5 years old were the largest group (40.2%). Refractive errors were the most common ocular disorders seen (31.6%), followed by conjunctival diseases (23.7%) and strabismus and amblyopia (13.8%). Refractive errors were recorded more frequently and statistically significant (p < 0.001) among (11-15) age group. Within the conjunctival diseases category, conjunctivitis and dry eyes was more prominent and statistically significant (p < 0.001) among the 6-10 year old age group. Within the strabismus and amblyopia category, convergent strabismus was more common and statistically significant among the youngest age group (0-5 years old). The most common causes of ocular morbidity are largely treatable or preventable. These results suggest the need for awareness campaigns and early intervention programs.

  6. Determination of the toxicity of intravitreal minocycline in rabbit eyes.

    PubMed

    Falavarjani, Khalil Ghasemi; Pourhabibi, Arash; Aghdam, Kaveh Abri; Hosseini, Seyed Bagher; Modarres, Mehdi; Pazouki, Abdolreza; Khanamiri, Hossein Nazari

    2016-09-01

    To evaluate the retinal toxicity of intravitreal minocycline in rabbit eyes. Intravitreal injection of minocycline with concentrations of 1000, 500, 250, 125 and 62.5 μg in 0.1 ml was performed in 10 New Zealand albino rabbits. Each concentration was injected into two rabbit eyes. For each dose, normal saline was injected in one contralateral eye and the other fellow eye remained non-injected. Electrophysiologic testing was performed before and 4 weeks after injections. The eyes were enucleated 4 weeks after injections and examined using light microscopy. The clinical examination was unremarkable after injections. Electroretinography recordings were significantly affected at all doses in at least one of the a- or b-waves of photopic or scotopic responses. Histopathologic examination revealed marked atrophy and loss of integrity in all retinal layers in all minocycline injected eyes. Contralateral eyes were normal. In our study, intravitreal minocycline was toxic to the retina in albino rabbits even at a concentration of 62.5 µg/0.1 ml.

  7. Longer Eye Contact Improves ADHD Children's Compliance with Parents' Commands

    ERIC Educational Resources Information Center

    Kapalka, G. M.

    2004-01-01

    This study evaluated the effectiveness of eye contact in reducing ADHD children's problems with compliance. Seventy-six parents of ADHD boys between ages 5 and 10 were randomized into two treatment groups and a control group. Repeated-measures ANOVA revealed that, as hypothesized, eye contact was effective in reducing ADHD children's problems with…

  8. Glaucoma: Eye-to-Eye with Dr. Rachel Bishop

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Glaucoma Eye-to-Eye with Dr. Rachel Bishop Past ... nerves are pale and cupped—signs of advanced glaucoma. Yet the patient wasn't aware of any ...

  9. Diabetic Eye Disease

    MedlinePlus

    ... Units Division of Epidemiology and Clinical Applications eyeGENE Research Directors Office Office of the Scientific Director Sheldon S. ... friends about diabetic eye disease. This module includes descriptive audio and captioning. Diabetic eye disease has no ...

  10. Needed: Instruments as Good as Our Eyes

    ERIC Educational Resources Information Center

    Brickell, Henry M.

    2011-01-01

    Evaluators use their eyes to see what is there, whether it is intended or not. But they use their test instruments to measure what is intended, whether it is there or not. Evaluators have been broadening their repertoire of instruments for years: curriculum-embedded tests, observer checklists, audiotape recorders, videotape recorders, unobtrusive…

  11. Autologous serum eye drops for dry eye.

    PubMed

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-02-28

    Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included trials. We contacted investigators to ask for missing data. For both primary and

  12. Eye-hand laterality and right thoracic idiopathic scoliosis.

    PubMed

    Catanzariti, Jean-François; Guyot, Marc-Alexandre; Agnani, Olivier; Demaille, Samantha; Kolanowski, Elisabeth; Donze, Cécile

    2014-06-01

    The adolescent idiopathic scoliosis (AIS) pathogenesis remains unknown. Certain studies have shown that there is a correlation between manual laterality and scoliotic deviation. A full study of manual laterality needs to be paired with one for visual dominance. With the aim of physiopathological research, we have evaluated the manual and visual laterality in AIS. A retrospective study from prospective data collection is used to evaluate the distribution of eye-hand laterality (homogeneous or crossed) of 65 right thoracic AIS (mean age 14.8 ± 1.8 years; mean Cobb angle: 32.8°) and a control group of 65 sex and age-matched (mean age 14.6 ± 1.8 years). The manual laterality was defined by the modified Edinburgh Handedness Inventory. The evaluation of the visual laterality is done using three tests (kaleidoscope test, hole-in-the-card test, distance-hole-in-the-card test). The group of right thoracic AIS presents a significantly higher frequency of crossed eye-hand laterality (63 %) than the control group (63 vs. 29.2 %; p < 0.001). In the AIS group, the most frequent association, within crossed laterality is "right hand dominant-left eye dominant" (82.9 %). There is no relationship with the Cobb angle. Those with right thoracic AIS show a higher occurrence of crossed eye-hand laterality. This could point physiopathological research of AIS towards functional abnormality of the optic chiasma through underuse of cross visual pathways, and in particular accessory optic pathways. It would be useful to explore this by carrying out research on AISs through neuroimaging and neurofunctional exploration.

  13. DNA methylation modulates H19 and IGF2 expression in porcine female eye

    PubMed Central

    Wang, Dongxu; Wang, Guodong; Yang, Hao; Liu, Haibo; Li, Cuie; Li, Xiaolan; Lin, Chao; Song, Yuning; Li, Zhanjun; Liu, Dianfeng

    2017-01-01

    Abstract The sexually dimorphic expression of H19/IGF2 is evolutionarily conserved. To investigate whether the expression of H19/IGF2 in the female porcine eye is sex-dependent, gene expression and methylation status were evaluated using quantitative real-time PCR (qPCR) and bisulfite sequencing PCR (BSP). We hypothesized that H19/IGF2 might exhibit a different DNA methylation status in the female eye. In order to evaluate our hypothesis, parthenogenetic (PA) cells were used for analysis by qPCR and BSP. Our results showed that H19 and IGF2 were over-expressed in the female eye compared with the male eye (3-fold and 2-fold, respectively). We observed a normal monoallelic methylation pattern for H19 differentially methylated regions (DMRs). Compared with H19 DMRs, IGF2 DMRs showed a different methylation pattern in the eye. Taken together, these results suggest that elevated expression of H19/IGF2 is caused by a specific chromatin structure that is regulated by the DNA methylation status of IGF2 DMRs in the female eye. PMID:28266684

  14. iDEAS: A web-based system for dry eye assessment.

    PubMed

    Remeseiro, Beatriz; Barreira, Noelia; García-Resúa, Carlos; Lira, Madalena; Giráldez, María J; Yebra-Pimentel, Eva; Penedo, Manuel G

    2016-07-01

    Dry eye disease is a public health problem, whose multifactorial etiology challenges clinicians and researchers making necessary the collaboration between different experts and centers. The evaluation of the interference patterns observed in the tear film lipid layer is a common clinical test used for dry eye diagnosis. However, it is a time-consuming task with a high degree of intra- as well as inter-observer variability, which makes the use of a computer-based analysis system highly desirable. This work introduces iDEAS (Dry Eye Assessment System), a web-based application to support dry eye diagnosis. iDEAS provides a framework for eye care experts to collaboratively work using image-based services in a distributed environment. It is composed of three main components: the web client for user interaction, the web application server for request processing, and the service module for image analysis. Specifically, this manuscript presents two automatic services: tear film classification, which classifies an image into one interference pattern; and tear film map, which illustrates the distribution of the patterns over the entire tear film. iDEAS has been evaluated by specialists from different institutions to test its performance. Both services have been evaluated in terms of a set of performance metrics using the annotations of different experts. Note that the processing time of both services has been also measured for efficiency purposes. iDEAS is a web-based application which provides a fast, reliable environment for dry eye assessment. The system allows practitioners to share images, clinical information and automatic assessments between remote computers. Additionally, it save time for experts, diminish the inter-expert variability and can be used in both clinical and research settings. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Which Eye Tracker is Right for Your Research Performance Evaluation of Several Cost Variant Eye Trackers

    DTIC Science & Technology

    2016-09-19

    REPORT TYPE 3. DATES COVERED (From - To) 21-10-16 Conference Proceedings 10/2015 – 03/2016 4. TITLE AND SUBTITLE Which eye tracker is right for...Force Research Laboratory 711th Human Performance Wing Airman Systems Directorate Warfighter Interface Division Applied Neuroscience Branch Wright...88ABW-2016-1334; Human Factors and Ergonomics Society 2016 Annual Meeting 19 – 23 Sept 2016 14. Though not often mentioned, the price point of many

  16. Paediatric eye injuries in Finland - Helsinki eye trauma study.

    PubMed

    Haavisto, Anna-Kaisa; Sahraravand, Ahmad; Holopainen, Juha M; Leivo, Tiina

    2017-06-01

    To determine the current population-based epidemiology, treatment, use of resources and outcomes of children's eye injuries in Finland. The study included all new patients, 16 years of age or under, with ocular or orbital traumas taken into care to the Helsinki University Eye Hospital (population base 1.5 million people) in 1 year. The follow-up period was 3 months. Two hundred and two children's eye injuries were treated. The eye injury incidence was 5.2-8.3 per 10 000 per year, including all minor and major eye traumas. Eye injury most likely occurred at the junior high school age (13-16 years). Thirty-three percentage of accidents took place at home and 24% at school or in day care. The most common causes were sports equipment (15%), contact with human body (12%) and superficial foreign bodies (11%). Excluding minor injuries, contusion was the most common diagnosis (n = 60, 30%). Eighty-seven percentage of contusion patients were estimated to need lifelong follow-up due to elevated glaucoma risk. Nine percentage of all patients had a permanent disability. Guns, fireworks, tools and pellet guns were relatively the most dangerous objects. Pellet guns caused 6% of eye injuries, 36% of them causing permanent impairment. The number of outpatient visits was altogether 443, inpatient days were 49, and 60 children had major surgeries. Use of protective eyewear would have prevented or diminished eye traumas caused by pellet gun, floorball, most of the firework and in many superficial foreign body. The use of pellet guns and protective eyewear should be more supervised. Fireworks and tools are not suitable toys for children. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Design and Real-World Evaluation of Eyes-Free Yoga: An Exergame for Blind and Low-Vision Exercise

    PubMed Central

    Rector, Kyle; Vilardaga, Roger; Lansky, Leo; Lu, Kellie; Bennett, Cynthia L.; Ladner, Richard E.; Kientz, Julie A.

    2017-01-01

    People who are blind or low vision may have a harder time participating in exercise due to inaccessibility or lack of encouragement. To address this, we developed Eyes-Free Yoga using the Microsoft Kinect that acts as a yoga instructor and has personalized auditory feedback based on skeletal tracking. We conducted two different studies on two different versions of Eyes-Free Yoga: (1) a controlled study with 16 people who are blind or low vision to evaluate the feasibility of a proof-of-concept and (2) an 8-week in-home deployment study with 4 people who are blind or low vision, with a fully functioning exergame containing four full workouts and motivational techniques. We found that participants preferred the personalized feedback for yoga postures during the laboratory study. Therefore, the personalized feedback was used as a means to build the core components of the system used in the deployment study and was included in both study conditions. From the deployment study, we found that the participants practiced Yoga consistently throughout the 8-week period (Average hours = 17; Average days of practice = 24), almost reaching the American Heart Association recommended exercise guidelines. On average, motivational techniques increased participant’s user experience and their frequency and exercise time. The findings of this work have implications for eyes-free exergame design, including engaging domain experts, piloting with inexperienced users, using musical metaphors, and designing for in-home use cases. PMID:29104712

  18. Treatment of contact lens related dry eye with antibacterial honey.

    PubMed

    Wong, Daniel; Albietz, Julie M; Tran, Huan; Du Toit, Cimonette; Li, Anita Hui; Yun, Tina; Han, Jee; Schmid, Katrina L

    2017-12-01

    Contact lens induced dry eye affects approximately 50% of contact lens wearers. The aim was to assess the effects of Manuka (Leptospermum sp.) honey eye drops (Optimel, Melcare, Australia) on dry eye in contact lens wearers. The safety of the honey eye drops in contact lens wear and contact lens wearers' compliance were also evaluated. Prospective, randomised, cross over study, examiner masked, pilot treatment trial. Twenty-four participants aged 20 to 55 years with contact lens related dry eye were recruited and randomised to two treatment groups; 20 completed the study. One group used Optimel eye drops twice a day for two weeks followed by conventional lubricant (Systane Ultra, Alcon) therapy for two weeks; the other group completed the treatments in the reverse order. Before and after each treatment dry eye symptomology, ocular surface inflammation, and tear quantity and quality were assessed. Participants completed a daily log detailing their usage of treatments and any issues. Dry eye symptoms improved significantly after Optimel treatment. Patients with more severe symptoms at baseline showed a greater improvement in symptoms. No significant differences were observed in the objective signs of dry eye; presumably because of the short treatment duration. Seventy-five% of contact lens wearers reported good adherence to Optimel treatment and 95% reported no issues using this product. Optimel Eye Drops reduce the symptoms of dry eye in contact lens wearers and are safe to use. A longer treatment period to assess the effect on clinical signs of dry eye is required. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Dark Circles under Eyes

    MedlinePlus

    Symptoms Dark circles under eyes By Mayo Clinic Staff Dark circles under your eyes generally implies that the darkening ... eye. Fatigue is the most common cause of dark circles under your eyes. Sometimes, what appear to ...

  20. Development of criteria for evaluating clinical response in thyroid eye disease (CRI-TED) using a modified Delphi technique

    PubMed Central

    Douglas, Raymond S.; Tsirbas, Angelo; Gordon, Mark; Lee, Diana; Khadavi, Nicole; Garneau, Helene Chokron; Goldberg, Robert A.; Cahill, Kenneth; Dolman, Peter J.; Elner, Victor; Feldon, Steve; Lucarelli, Mark; Uddin, Jimmy; Kazim, Michael; Smith, Terry J.; Khanna, Dinesh

    2014-01-01

    To identify components of a provisional clinical response index for thyroid eye disease (CRI-TED) using a modified Delphi technique. The International Thyroid Eye Disease Society (ITEDS) conducted a structured, 3-round Delphi exercise establishing consensus for a core set of measures for clinical trials in TED. The steering committee discussed the results in a face-to-face meeting (nominal group technique) and evaluated each criterion with respect to its feasibility, reliability, redundancy, and validity. Redundant measures were consolidated or excluded. Criteria were parsed into 11 domains for the Delphi surveys. Eighty four respondents participated in the Delphi-1 survey, providing 220 unique items. Ninety- two members (100% of the respondents from Delphi 1 plus eight new participants) responded in Delphi-2 and rated the same 220 items. Sixty-four members (76% of participants) rated 153 criteria in Delphi-3 (67 criteria were excluded due to redundancy). Criteria with a mean greater than 6 (1 least appropriate to 9 most appropriate) were further evaluated by the nominal group technique and provisional core measures were chosen. Using a Delphi exercise, we developed provisional core measures for assessing disease activity and severity in clinical trials of therapies for TED. These measures will be iteratively refined for use in multicenter clinical trials. PMID:19752424

  1. Is eye damage caused by stereoscopic displays?

    NASA Astrophysics Data System (ADS)

    Mayer, Udo; Neumann, Markus D.; Kubbat, Wolfgang; Landau, Kurt

    2000-05-01

    A normal developing child will achieve emmetropia in youth and maintain it. Thereby cornea, lens and axial length of the eye grow astonishingly coordinated. In the last years research has evidenced that this coordinated growing process is a visually controlled closed loop. The mechanism has been studied particularly in animals. It was found that the growth of the axial length of the eyeball is controlled by image focus information from the retina. It was shown that maladjustment can occur by this visually-guided growth control mechanism that result in ametropia. Thereby it has been proven that e.g. short-sightedness is not only caused by heredity, but is acquired under certain visual conditions. It is shown that these conditions are similar to the conditions of viewing stereoscopic displays where the normal accommodation convergence coupling is disjoint. An evaluation is given of the potential of damaging the eyes by viewing stereoscopic displays. Concerning this, different viewing methods for stereoscopic displays are evaluated. Moreover, clues are given how the environment and display conditions shall be set and what users shall be chosen to minimize the risk of eye damages.

  2. Dry eye evaluation and correlation analysis between tear film stability and corneal surface regularity after small incision lenticule extraction.

    PubMed

    Zhang, Hui; Wang, Yan

    2017-09-22

    To investigate the dry eye after small incision lenticule extraction (SMILE) and explore the correlations between changes in the tear film stability, the tear secretion and the corneal surface regularity. Sixty-two eyes of 22 men and 13 women who underwent SMILE were included in this study. Corneal topography was measured to assess the index of surface variance (ISV) and the index of vertical asymmetry (IVA). Dry eye tests including subjective symptom questionnaire, tear breakup time (TBUT), corneal fluorescein staining and Schirmer's test (ST) were evaluated before and at 1 and 6 months postoperatively. TBUT was found to be significantly decreased from 9.8 ± 3.4 s preoperatively to 7.4 ± 3.8 s at 1 month and 6.5 ± 3.6 s at 6 months (both P < 0.001). There was a significant decrease in ST at 1 month postoperatively (P = 0.012); however, ST returned to baseline by 6 months (P = 0.522). Both ISV and IVA significantly increased after the surgery (all P < 0.001). In addition, the changes in TBUT were negatively correlated with the increases in ISV and IVA (r = -0.343, P = 0.006 and r = -0.311, P = 0.014, respectively). Patients undergoing SMILE might develop a short-TBUT type of dry eye. Corneal surface regularity indices might be helpful in the assessment of tear film stability following SMILE procedure.

  3. Diagnosing dry eye with dynamic-area high-speed videokeratoscopy

    NASA Astrophysics Data System (ADS)

    Alonso-Caneiro, David; Turuwhenua, Jason; Iskander, D. Robert; Collins, Michael J.

    2011-07-01

    Dry eye syndrome is one of the most commonly reported eye health conditions. Dynamic-area high-speed videokeratoscopy (DA-HSV) represents a promising alternative to the most invasive clinical methods for the assessment of the tear film surface quality (TFSQ), particularly as Placido-disk videokeratoscopy is both relatively inexpensive and widely used for corneal topography assessment. Hence, improving this technique to diagnose dry eye is of clinical significance and the aim of this work. First, a novel ray-tracing model is proposed that simulates the formation of a Placido image. This model shows the relationship between tear film topography changes and the obtained Placido image and serves as a benchmark for the assessment of indicators of the ring's regularity. Further, a novel block-feature TFSQ indicator is proposed for detecting dry eye from a series of DA-HSV measurements. The results of the new indicator evaluated on data from a retrospective clinical study, which contains 22 normal and 12 dry eyes, have shown a substantial improvement of the proposed technique to discriminate dry eye from normal tear film subjects. The best discrimination was obtained under suppressed blinking conditions. In conclusion, this work highlights the potential of the DA-HSV as a clinical tool to diagnose dry eye syndrome.

  4. Quality control evaluation of Keshamasi, Keshanjana and Keshamasi eye ointment

    PubMed Central

    Dhiman, Kartar Singh; Shukla, Vinay J.; Bhalodia, Nayan R.; Sharma, Vinay R.

    2014-01-01

    Background: Keshanjana (collyrium) is a well known Ayurvedic preparation prepared out of Keshamasi (ash prepared by scalp hairs) mixed with Goghrita (cow's ghee). This medicine is indicated for the treatment of Shushkakshipaka (dry eye syndrome) in the classical literature of Ayurveda; hence, it was under taken for standardization and clinical evaluation in an extra-mural research project from Central Council for Research in Ayurvedic Sciences, Department of AYUSH, New Delhi. Aim: To develop standard quality parameters for the Keshamasi, Keshanjana and Keshamasi ointment. Materials and Methods: Scalp hairs of male and females collected from saloons were converted to classical Masi Kalpana and mixed with cow ghee and petrolatum in the ratio of 1:5 to prepare the Keshanjana and Keshamasi ointment respectively. Standard Operation Procedure (SOP) were adopted and recorded accordingly. The raw material, furnished products and plain Goghrita were subjected for quality control parameters i.e., physico-chemical evaluation, anti-microbial study, particle size analysis, heavy metal analysis through inductive couple plasma spectroscopy with high performance thin layer liquid chromatography fingerprints. Results: Rancidity was negative in all the samples, indicating that the physico-chemical parameters are in acceptable range. Lead and zinc were present in most of the samples; while all samples are were free from microbial contamination. Conclusion: As no standards are available to compare the results of the current study, the observations cannot be compared. Thus the profile generated in the current study can be considered as standard to refer in future studies. PMID:25364202

  5. Assessment of Eye Fatigue Caused by 3D Displays Based on Multimodal Measurements

    PubMed Central

    Bang, Jae Won; Heo, Hwan; Choi, Jong-Suk; Park, Kang Ryoung

    2014-01-01

    With the development of 3D displays, user's eye fatigue has been an important issue when viewing these displays. There have been previous studies conducted on eye fatigue related to 3D display use, however, most of these have employed a limited number of modalities for measurements, such as electroencephalograms (EEGs), biomedical signals, and eye responses. In this paper, we propose a new assessment of eye fatigue related to 3D display use based on multimodal measurements. compared to previous works Our research is novel in the following four ways: first, to enhance the accuracy of assessment of eye fatigue, we measure EEG signals, eye blinking rate (BR), facial temperature (FT), and a subjective evaluation (SE) score before and after a user watches a 3D display; second, in order to accurately measure BR in a manner that is convenient for the user, we implement a remote gaze-tracking system using a high speed (mega-pixel) camera that measures eye blinks of both eyes; thirdly, changes in the FT are measured using a remote thermal camera, which can enhance the measurement of eye fatigue, and fourth, we perform various statistical analyses to evaluate the correlation between the EEG signal, eye BR, FT, and the SE score based on the T-test, correlation matrix, and effect size. Results show that the correlation of the SE with other data (FT, BR, and EEG) is the highest, while those of the FT, BR, and EEG with other data are second, third, and fourth highest, respectively. PMID:25192315

  6. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes.

    PubMed

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. The mean follow-up duration was 11.7 ± 5.5 (range, 6-23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg ( p =0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 ( p =0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  7. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    PubMed Central

    İmamoğlu, Serhat

    2018-01-01

    Purpose To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. Results The mean follow-up duration was 11.7 ± 5.5 (range, 6–23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg (p=0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 (p=0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Conclusions Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation. PMID:29862068

  8. Efficacy of osmoprotectants on prevention and treatment of murine dry eye.

    PubMed

    Chen, Wei; Zhang, Xin; Li, Jinyang; Wang, Yu; Chen, Qi; Hou, Chao; Garrett, Qian

    2013-09-19

    To evaluate the efficacy of osmoprotectants on prevention and treatment of dry eye in a murine model. Dry eye was induced in mice by using an intelligently controlled environmental system (ICES). Osmoprotectants betaine, L-carnitine, erythritol, or vehicle (PBS) were topically administered to eyes four times daily following two schedules: schedule 1 (modeling prevention): dosing started at the beginning of housing in ICES and lasted for 21 or 35 days; schedule 2 (modeling treatment): dosing started after ICES-housed mice developed dry eye (day 21), continuing until day 35. Treatment efficacy was evaluated for corneal fluorescein staining; corneal epithelial apoptosis by TUNEL and caspase-3 assays; goblet cell numbers by PAS staining; and expression of inflammatory mediators, TNF-α, IL-17, IL-6, or IL-1β by using RT-PCR on days 0, 14, 21, and/or 35. Compared with vehicle, prophylactic administration of betaine, L-carnitine, or erythritol significantly decreased corneal staining and expression of TNF-α and IL-17 on day 21 (schedule 1). Treatment of mouse dry eye with osmoprotectants significantly reduced corneal staining on day 35 compared with day 21 (schedule 2). Relative to vehicle, L-carnitine treatment of mouse dry eye for 14 days (days 21 to 35) resulted in a significant reduction in corneal staining, number of TUNEL-positive cells, and expression of TNF-α, IL-17, IL-6, or IL-1β, as well as significantly increased the number of goblet cells. Topical application of betaine, L-carnitine, or erythritol systematically limited progression of environmentally induced dry eye. L-carnitine can also reduce the severity of such dry-eye conditions.

  9. Estimating outflow facility through pressure dependent pathways of the human eye

    PubMed Central

    Gardiner, Bruce S.

    2017-01-01

    We develop and test a new theory for pressure dependent outflow from the eye. The theory comprises three main parameters: (i) a constant hydraulic conductivity, (ii) an exponential decay constant and (iii) a no-flow intraocular pressure, from which the total pressure dependent outflow, average outflow facilities and local outflow facilities for the whole eye may be evaluated. We use a new notation to specify precisely the meaning of model parameters and so model outputs. Drawing on a range of published data, we apply the theory to animal eyes, enucleated eyes and in vivo human eyes, and demonstrate how to evaluate model parameters. It is shown that the theory can fit high quality experimental data remarkably well. The new theory predicts that outflow facilities and total pressure dependent outflow for the whole eye are more than twice as large as estimates based on the Goldman equation and fluorometric analysis of anterior aqueous outflow. It appears likely that this discrepancy can be largely explained by pseudofacility and aqueous flow through the retinal pigmented epithelium, while any residual discrepancy may be due to pathological processes in aged eyes. The model predicts that if the hydraulic conductivity is too small, or the exponential decay constant is too large, then intraocular eye pressure may become unstable when subjected to normal circadian changes in aqueous production. The model also predicts relationships between variables that may be helpful when planning future experiments, and the model generates many novel testable hypotheses. With additional research, the analysis described here may find application in the differential diagnosis, prognosis and monitoring of glaucoma. PMID:29261696

  10. Cyclodextrins in eye drop formulations: enhanced topical delivery of corticosteroids to the eye.

    PubMed

    Loftsson, Thorsteinn; Stefánsson, Einar

    2002-04-01

    Cyclodextrins are cylindrical oligosaccharides with a lipophilic central cavity and hydrophilic outer surface. They can form water-soluble complexes with lipophilic drugs, which 'hide' in the cavity. Cyclodextrins can be used to form aqueous eye drop solutions with lipophilic drugs, such as steroids and some carbonic anhydrase inhibitors. The cyclodextrins increase the water solubility of the drug, enhance drug absorption into the eye, improve aqueous stability and reduce local irritation. Cyclodextrins are useful excipients in eye drop formulations of various drugs, including steroids of any kind, carbonic anhydrase inhibitors, pilocarpine, cyclosporins, etc. Their use in ophthalmology has already begun and is likely to expand the selection of drugs available as eye drops. In this paper we review the properties of cyclodextrins and their application in eye drop formulations, of which their use in the formulation of dexamethasone eye drops is an example. Cyclodextrins have been used to formulate eye drops containing corticosteroids, such as dexamethasone, with levels of concentration and ocular absorption which, according to human and animal studies, are many times those seen with presently available formulations. Cyclodextrin-based dexamethasone eye drops are well tolerated in the eye and seem to provide a higher degree of bioavailability and clinical efficiency than the steroid eye drop formulations presently available. Such formulations offer the possibility of once per day application of corticosteroid eye drops after eye surgery, and more intensive topical steroid treatment in severe inflammation. While cyclodextrins have been known for more than a century, their use in ophthalmology is just starting. Cyclodextrins are useful excipients in eye drop formulations for a variety of lipophilic drugs. They will facilitate eye drop formulations for drugs that otherwise might not be available for topical use, while improving absorption and stability and decreasing

  11. Fish eye optics

    NASA Astrophysics Data System (ADS)

    Hudec, R.; Michalova, S.

    2017-07-01

    We report on small student (high—school) project of the Czech Academy of Sciences dealing with animal (fish) eyes and possible application in science and technology. Albeit most fishes have refractive eyes, the recent discoveries confirm that some fishes have reflective eyes with strange arrangements as well.

  12. Comparison of 0.3% Hypotonic and Isotonic Sodium Hyaluronate Eye Drops in the Treatment of Experimental Dry Eye.

    PubMed

    Li, Ying; Cui, Lian; Lee, Hyo Seok; Kang, Yeon Soo; Choi, Won; Yoon, Kyung Chul

    2017-08-01

    To compare the efficacy of 0.3% hypotonic and isotonic sodium hyaluronate (SH) eye drops in the treatment of experimental dry eye. Experimental dry eye was established in female C57BL/6 mice by subcutaneous scopolamine injection and an air draft. The mice were divided into three groups (n = 15): control, preservative-free 0.3% isotonic SH, and preservative-free 0.3% hypotonic SH. The tear volume, tear film break-up time, and corneal fluorescein staining scores were measured 5 and 10 days after treatment. After conjunctival tissues were excised at 10 days, the levels of interleukin (IL)-6, IL-17, interferon (IFN)-γ, and IFN-γ inducible protein-10 were determined using the multiplex immunobead assay. In addition, PAS staining and flow cytometry were performed to evaluate the counts of conjunctival goblet cells and CD4+ IFN-γ+ T cells. Mice treated with 0.3% hypotonic SH showed a significant decrease in corneal staining scores (P = 0.04) and the levels of IL-6 (16.7 ± 1.4 pg/mL, P = 0.02) and IFN-γ (46.5 ± 11.5 pg/mL, P = 0.02) compared to mice treated with 0.3% isotonic SH (IL-6; 32.5 ± 8.8 pg/mL, IFN-γ; 92.0 ± 16.0 pg/mL) at day 10. Although no significant difference in CD4+ IFN-γ+ T cell numbers was observed, goblet cell counts were higher in the hyopotonic SH group than in the isotonic SH group (P = 0.02). When compared to 0.3% isotonic SH eye drops, 0.3% hypotonic SH eye drops can be more effective by improving corneal staining scores, decreasing inflammatory molecules, and increasing goblet cell counts for experimental dry eye. These data suggest that hypotonic artificial tears may be useful as an adjunctive treatment for inflammatory dry eye.

  13. Your Eyes

    MedlinePlus

    ... that nourishes the eye and keeps it healthy. Light, Lens, Action These next parts are really cool, ... back of the eye. Rods and Cones Process Light The retina uses special cells called rods and ...

  14. Eye emergencies

    MedlinePlus

    ... tissue covering the front of the eye. Dust, sand, and other debris can easily enter the eye. ... clear itself of tiny objects, like eyelashes and sand, through blinking and tearing. If not, don't ...

  15. Association of IL-21 cytokine with severity of primary Sjögren syndrome dry eye.

    PubMed

    Lim, Sung A; Nam, Doo Hyun; Lee, Jee Hye; Kwok, Seung-Ki; Park, Sung-Hwan; Chung, So-Hyang

    2015-03-01

    IL-21 plays an important role in primary Sjögren syndrome (SS) pathogenesis. The purpose of this study was to evaluate IL-21 expression in tears and the conjunctiva and to analyze the impact of IL-21 on primary SS dry eyes. Eighty subjects were enrolled in this study: 30 patients with primary SS dry eye (30 eyes); 30 patients with non-SS dry eye (30 eyes), and 20 normal controls. Tear IL-21 levels were measured by flow cytometry, and IL-21 gene expression in the conjunctiva from impression cytology was evaluated by quantitative polymerase chain reaction. Ocular Surface Disease Index, tear film breakup time, Schirmer I test, and ocular surface staining scores were obtained for all patients. Primary SS dry eyes had significantly higher tear IL-21 levels than non-SS dry eyes and normal controls (P < 0.01). In addition, IL-21 gene expression in the conjunctiva was also higher in primary SS dry eyes than in non-SS dry eyes and normal controls (P < 0.01). However, there were no significant differences in IL-21 expression in tears and the conjunctiva between non-SS dry eyes and controls. The tear IL-21 level was significantly correlated with ocular surface stain scores (r = 0.54, P < 0.01) and Schirmer I test values (r = -0.23, P < 0.05) in primary SS dry eyes. Our findings suggest that severity of primary SS dry eye is associated with IL-21.

  16. Rotation of lathe-cut hydrogel lenses on the eye.

    PubMed

    Harris, M G; Harris, K L; Ruddell, D

    1976-01-01

    The rotation lathe-cut HydroCurveTM gel contact lens was measured on six eyes to evaluate the parameters that influence lens rotation and to determine if this lens could be used to correct astigmatism. Of the 72 observations made, 73.6% showed some lens rotation, and 33.4% of the sample rotated more than 5 degrees per 10 blinks. Of the observations in which rotation was noted, 88.7% were encyclorotation. These results are similar to those found for spin-cast hydrogel lenses. None of the lens parameters evaluated seemed to be related to lens rotation, whereas the eye parameters studied were. Lenses were more likely to rotate on eyes with smaller corneal diameters, smaller palpebral apertures, and corneal curvatures steeper than 4 3.00 DK (X2, N =72, p less than 0.05). Our findings indicate that some method of lens stabilization will be needed before lathe-cut hydrogel lenses can be used to effectively correct astigmatism.

  17. Evaluation of SARs for the prediction of eye irritation/corrosion potential: structural inclusion rules in the BfR decision support system.

    PubMed

    Tsakovska, I; Saliner, A Gallegos; Netzeva, T; Pavan, M; Worth, A P

    2007-01-01

    The proposed REACH regulation within the European Union (EU) aims to minimise the number of laboratory animals used for human hazard and risk assessment while ensuring adequate protection of human health and the environment. One way to achieve this goal is to develop non-testing methods, such as (quantitative) structure-activity relationships ([Q]SARs), suitable for identifying toxicological hazard from chemical structure and physicochemical properties alone. A database containing data submitted within the EU New Chemicals Notification procedure was compiled by the German Bundesinstitut für Risikobewertung (BfR). On the basis of these data, the BfR built a decision support system (DSS) for the prediction of several toxicological endpoints. For the prediction of eye irritation and corrosion potential, the DSS contains 31 physicochemical exclusion rules evaluated previously by the European Chemicals Bureau (ECB), and 27 inclusion rules that define structural alerts potentially responsible for eye irritation and/or corrosion. This work summarises the results of a study carried out by the ECB to assess the performance of the BfR structural rulebase. The assessment included: (a) evaluation of the structural alerts by using the training set of 1341 substances with experimental data for eye irritation and corrosion; and (b) external validation by using an independent test set of 199 chemicals. Recommendations are made for the further development of the structural rules in order to increase the overall predictivity of the DSS.

  18. Comparing Interrater reliability between eye examination and eye self-examination 1

    PubMed Central

    de Lima, Maria Alzete; Pagliuca, Lorita Marlena Freitag; do Nascimento, Jennara Cândido; Caetano, Joselany Áfio

    2017-01-01

    Resume Objective: to compare Interrater reliability concerning two eye assessment methods. Method: quasi-experimental study conducted with 324 college students including eye self-examination and eye assessment performed by the researchers in a public university. Kappa coefficient was used to verify agreement. Results: reliability coefficients between Interraters ranged from 0.85 to 0.95, with statistical significance at 0.05. The exams to check for near acuity and peripheral vision presented a reasonable kappa >0.2. The remaining coefficients were higher, ranging from very to totally reliable. Conclusion: comparatively, the results of both methods were similar. The virtual manual on eye self-examination can be used to screen for eye conditions. PMID:29069269

  19. Larch arabinogalactan for dry eye protection and treatment of corneal lesions: investigations in rabbits.

    PubMed

    Burgalassi, Susi; Nicosia, Nadia; Monti, Daniela; Falcone, Giulia; Boldrini, Enrico; Chetoni, Patrizia

    2007-12-01

    The aim of the present study was to investigate the corneal protective and healing properties of arabinogalactan (AG), a natural polysaccharide present in conifers of the genus Larix (Larch). AG was tested in comparison with other two polysaccharides possessing well-established properties in the treatment of dry eye: tamarind seed polysaccharide and hyaluronic acid. The AG formulation was subjected to the following investigations: rheologic measurements; evaluation of mucoadhesive properties by rheologic interaction with mucin; ferning test; and in vivo evaluation on rabbits, including treatment of an experimental dry eye; evaluation of the preocular retention; and evaluation of healing rate of experimental corneal wound. AG dispersions showed a newtonian nonviscous behavior, eta = 1.6 mPa . s for 10% w/w solution; it possessed good mucoadhesive properties useful for retention on the eye surface. In fact, a prolonged time of residence in rabbit eyes was ascertained using fluorescein-labeled AG. Five percent (5.0%) w/w AG exerted a good protective effect against the appearance of corneal dry spots. It also reduced significantly the healing time of an experimental corneal lesion since 27 h after the first treatment. These findings suggest that AG may be a potential therapeutic product for dry eye protection and for the treatment of corneal wounds.

  20. Eye Emergencies

    MedlinePlus

    ... The Marfan Foundation Marfan & Related Disorders What is Marfan Syndrome? What are Related Disorders? What are the Signs? ... Emergencies Eye Emergencies Lung Emergencies Surgeries Eye Emergencies Marfan syndrome significantly increases your risk of retinal detachment, a ...

  1. Utilisation of eye-care services: the effect of Scotland's free eye examination policy.

    PubMed

    Dickey, Heather; Ikenwilo, Divine; Norwood, Patricia; Watson, Verity; Zangelidis, Alexandros

    2012-12-01

    To examine how the introduction of free eye examinations in Scotland affected people's use of eye care services. Particularly, to assess if more people are now having their eyes examined regularly, and whether there are differences in the way people responded to the policy across socio-economic groups. Using the British Household Panel Survey, eye test uptake and frequency in Scotland is compared to the rest of the UK pre and post policy. Propensity to have eye tests and responsiveness to the policy is compared across socio-economic groups. In addition, using data available from a chain of private ophthalmic opticians, clinical characteristics of eye examination patients are compared pre- and post-policy. There is evidence that suggests that people responded positively to the policy. In particular, a higher percentage of people in Scotland have their eyes tested after the free eye care policy was introduced. Interestingly, the response to the policy varies between the different socio-economic groups. For the highest earners and most educated groups, the proportion of people having an eye test increased more than for those groups with lower income or lower education. Although the policy succeeded in getting more people to have their eyes tested, the socio-economic differences observed suggest that the policy has not reached the more vulnerable segments in society to the same extent, in particular, those with low education and low income. As a result, eye care services utilisation inequalities have widened in Scotland after the free eye care policy was introduced. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. LASIK and dry eye.

    PubMed

    Toda, Ikuko

    2007-01-01

    Dry eye is one of the most common complications after laser-assisted in situ keratomileusis (LASIK). The clinical signs of post-LASIK dry eye include positive vital staining of ocular surface, decreased tear film breakup time and Schirmer test, reduced corneal sensitivity, and decreased functional visual acuity. The symptoms and signs last at least 1 month after LASIK. Although the mechanisms for developing post-LASIK dry eye are not completely understood, loss of corneal innervation by flap-making may affect the reflex loops of the corneal-lacrimal gland, corneal-blinking, and blinking-meibomian gland, and blinking-meibomian gland, resulting in decreased aqueous and lipid tear secretion and mucin expression. As LASIK enhancement by flap-lifting induces less dry eye symptoms and signs than first surgery, it is suggested that other factors rather than loss of neurotrophic effect may be involved in the mechanisms of post-LASIK dry eye. The treatments of dry eye include artificial tears, topical cyclosporine, hot compress, punctal plugs, and autologous serum eye drops. For patients with severe preoperative dry eye, a combination of punctal plugs and serum eye drops is required to be used before surgery.

  3. Mechanisms and management of dry eye in cataract surgery patients.

    PubMed

    Sutu, Christine; Fukuoka, Hideki; Afshari, Natalie A

    2016-01-01

    To provide a summary of the mechanisms that may cause dry eye after cataract surgery and discuss available and upcoming treatment modalities. Development or worsening of dry eye symptoms after cataract surgery is multifactorial with corneal nerve transection, inflammation, goblet cell loss, and meibomian gland dysfunction commonly cited as underlying disorders. With increasing awareness of the prevalence of dry eye disease, current surgical techniques are being analyzed for their contribution to the issue. Although many classic interventions, such as artificial tears and anti-inflammatory drops, remain first-line treatment options, they may not adequately address abnormalities of the tear film. The trend has been to create new drugs and technologies that target meibomian gland deficiencies and restore goblet cell numbers. Therapy for postoperative dry eye symptoms should be determined based on symptom severity and which underlying cause is most prominent at a given time. Patients with high-level risk factors for dry eye should be evaluated preoperatively to determine whether they have preexisting dry eye disease or if they are susceptible to developing disease after surgery.

  4. Effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals.

    PubMed

    Raizman, M B; Rothman, J S; Maroun, F; Rand, W M

    2000-12-01

    To evaluate the effect of eye rubbing on signs and symptoms of allergic conjunctivitis in cat-sensitive individuals. Two prospective, nonrandomized comparative studies. Thirteen patients in the first study and 20 patients in the second study with a documented history of acute allergic conjunctivitis induced by exposure to cats were enrolled. In the first trial, all patients had one eye rubbed 15 times by the investigator without exposure to airborne allergens. Both eyes were evaluated after 5, 15, 30, and 60 minutes using subject questionnaires and slit-lamp examination. At least 1 week later, each patient was exposed to cat dander for 75 minutes; 15 minutes after entering the cat room, each patient had one eye rubbed 15 times by the examiner. Subjects' eyes were then evaluated using questionnaires and slit-lamp examination. In the second trial, the visits were identical to the first trial, except that the rubbed eye in each visit was rubbed 20 times and with more force, and that patients wore masks during exposure to cat dander. In both studies, the difference between patients' rubbed and nonrubbed eyes with respect to ocular itching, chemosis, and hyperemia was noted 5, 15, 30, and 60 minutes after controlled eye rubbing. Without exposure to the cat room, rubbed eyes exhibited increased itching at 5 minutes in both studies and at 15 minutes in the second study (P < 0.05), increased chemosis at 5 and 15 minutes in the second study (P < 0.05), and increased hyperemia at 5 minutes in the second study (P < 0.05) compared with nonrubbed eyes. During exposure to cat dander, rubbed eyes consistently exhibited increased itching at 5, 15, and 30 minutes in the first and second study as well as at 60 minutes in the second study compared with nonrubbed eyes. Furthermore, during exposure to cat dander, rubbed eyes consistently exhibited increased chemosis at 5 and 15 minutes (P < 0.05) and increased hyperemia at 5, 15, and 30 minutes (P < 0.05) in the second study compared

  5. Histopathologic evaluation of the anterior segment of eyes enucleated due to glaucoma secondary to primary lens displacement in 13 canine globes.

    PubMed

    Alario, Anthony F; Pizzirani, Stefano; Pirie, Christopher G

    2013-07-01

    PURPOSE  To describe histologic anterior segment changes in eyes affected with primary lens displacement (PLD) and secondary glaucoma. METHODS  Histologic sections stained with H&E from canine eyes enucleated because of PLD and secondary glaucoma were examined. RESULTS  Thirteen eyes from 12 patients were evaluated. Four dogs were castrated males and eight spayed females. Median age was 8 years of age (range 3-13). Breeds included seven terriers and five other breeds. All eyes examined demonstrated varying degrees of inflammation involving the iris and cleft. Mononuclear and melanophagic infiltration of the cleft was found in all specimens. Four globes also showed polymorphonuclear infiltrate. Pre-iridal fibrovascular membranes were clearly identified in 10 of 13 eyes. Total inflammatory score was significantly greater in all globes examined compared with an age-matched group of normal dogs. The posterior pigmented iris epithelium demonstrated a consistent pattern of hyperplasia and/or hypertrophy and cystic degeneration, more prominent in the more central regions. In some cases, hyperplasia was of greatest severity in the mid-iris and associated with thinning or flattening of the pupillary region. CONCLUSIONS  These results suggest that lens instability may be associated with chronic inflammation and secondary glaucoma. Mechanical irritation from an unstable lens may result in hypertrophy and/or hyperplasia of the posterior pigmented iris epithelium and subsequent cellular exfoliation and release of melanin. An inflammatory reaction directly or indirectly related to melanin release may obstruct the outflow pathways ultimately leading to glaucoma and loss of vision. Use of topical steroids may be warranted in dogs with PLD. © 2012 American College of Veterinary Ophthalmologists.

  6. Magnetic eye tracking in mice

    PubMed Central

    Payne, Hannah L

    2017-01-01

    Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455

  7. Dwarf Eye Disorder

    ERIC Educational Resources Information Center

    Science Teacher, 2005

    2005-01-01

    Johns Hopkins researchers at the Wilmer Eye Institute have discovered what appears to be the first human gene mutation that causes extreme farsightedness. The researchers report that nanophthalmos, Greek for "dwarf eye," is a rare, potentially blinding disorder caused by an alteration in a gene called MFRP that helps control eye growth and…

  8. The effect of arousal and eye gaze direction on trust evaluations of stranger's faces: A potential pathway to paranoid thinking.

    PubMed

    Abbott, Jennie; Middlemiss, Megan; Bruce, Vicki; Smailes, David; Dudley, Robert

    2018-09-01

    When asked to evaluate faces of strangers, people with paranoia show a tendency to rate others as less trustworthy. The present study investigated the impact of arousal on this interpersonal bias, and whether this bias was specific to evaluations of trust or additionally affected other trait judgements. The study also examined the impact of eye gaze direction, as direct eye gaze has been shown to heighten arousal. In two experiments, non-clinical participants completed face rating tasks before and after either an arousal manipulation or control manipulation. Experiment one examined the effects of heightened arousal on judgements of trustworthiness. Experiment two examined the specificity of the bias, and the impact of gaze direction. Experiment one indicated that the arousal manipulation led to lower trustworthiness ratings. Experiment two showed that heightened arousal reduced trust evaluations of trustworthy faces, particularly trustworthy faces with averted gaze. The control group rated trustworthy faces with direct gaze as more trustworthy post-manipulation. There was some evidence that attractiveness ratings were affected similarly to the trust judgements, whereas judgements of intelligence were not affected by higher arousal. In both studies, participants reported low levels of arousal even after the manipulation and the use of a non-clinical sample limits the generalisability to clinical samples. There is a complex interplay between arousal, evaluations of trustworthiness and gaze direction. Heightened arousal influences judgements of trustworthiness, but within the context of face type and gaze direction. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. New testing options for diagnosing and grading dry eye disease.

    PubMed

    Foulks, Gary N; Pflugfelder, Stephen C

    2014-06-01

    To describe new options for diagnosis and severity grading of dry eye disease. Perspective on technological advancements to identify tear dysfunction and their value in diagnosing and grading dry eye disease. Evidence is presented on new and evolving technologies to measure tear stability, composition, and meniscus height and their role in dry eye diagnosis and therapeutic efficacy grading is assessed. Evolving concepts regarding pathogenesis and new technologies to evaluate the tears and ocular surface have improved the ability to diagnose, classify, and grade the severity of dry eye disease. New technologies include noninvasive imaging of tear stability and tear meniscus height as a measure of tear volume and tear composition (osmolarity, lacrimal factors, inflammatory mediators, growth and differentiation factors). Approved tests, such as tear osmolarity and tear imaging, are being integrated into clinical practice and may eventually supplant certain traditional tests that have greater variability and less sensitivity. Other tests, such as molecular assays of tears and conjunctival cells, are currently being used in studies investigating pathogenesis and therapeutic mechanism of action. They may eventually translate to routine clinical practice. New technologies have emerged that can noninvasively evaluate the tears and measure disease-associated compositional changes. These tests are being integrated into clinical practice and therapeutic trials for diagnosis, classification, and severity grading of dry eye disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Efficacy of punctal occlusion in management of dry eyes after laser in situ keratomileusis for myopia.

    PubMed

    Alfawaz, Abdullah M; Algehedan, Saeed; Jastaneiah, Sabah S; Al-Mansouri, Samir; Mousa, Ahmed; Al-Assiri, Abdullah

    2014-03-01

    To evaluate the effect of punctal plug use in preventing dry eye after laser in situ keratomileusis (LASIK). A randomized clinical trial at a tertiary eye care center, Riyadh, Saudi Arabia. Participants underwent LASIK for myopia in both eyes and a lower punctal occlusion in one eye only while the other eye served as control. Both eyes received the same postoperative medications except for lubricant duration (subject eye: four times per day for one week; control eye: four times per day for 6 months). Participants were evaluated at 1 week, 2, and 6 months after surgery for signs and symptoms of dry eye. The main outcome measures were visual acuity; ocular surface parameters; and Ocular Surface Disease Index questionnaire. Seventy-eight eyes of 39 patients were included in this study. The Ocular Surface Disease Index scores of eyes with punctal plugs were better at all follow-up visits, and the differences between both eyes were statistically significant (1 week, p < 0.0001; 2 months, p < 0.0001; 6 months, p = 0.008). At the final follow-up visit, the percentage of normal eyes was higher in eyes with punctal plugs for all ocular surface parameters (Schirmer 1 test, 94.9%; tear breakup time, 77.8%; punctate epithelial keratitis score, 71.8%) compared to eyes without occlusion (Schirmer 1 test, 92.3%; tear breakup time, 58.3%; punctate epithelial keratitis score, 53.8%); however, such differences were not statistically significant. Punctal plug insertion after LASIK surgeries may minimize the need for frequent lubricant application and hence improve patient satisfaction.

  11. Autologous serum eye drops for dry eye

    PubMed Central

    Pan, Qing; Angelina, Adla; Marrone, Michael; Stark, Walter J; Akpek, Esen K

    2017-01-01

    Background Theoretically, autologous serum eye drops (AS) offer a potential advantage over traditional therapies on the assumption that AS not only serve as a lacrimal substitute to provide lubrication but contain other biochemical components that allow them to mimic natural tears more closely. Application of AS has gained popularity as second-line therapy for patients with dry eye. Published studies on this subject indicate that autologous serum could be an effective treatment for dry eye. Objectives We conducted this review to evaluate the efficacy and safety of AS given alone or in combination with artificial tears as compared with artificial tears alone, saline, placebo, or no treatment for adults with dry eye. Search methods We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2016), Embase (January 1980 to July 2016), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to July 2016), the ISRCTN registry (www.isrctn.com/editAdvancedSearch), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We also searched the Science Citation Index Expanded database (December 2016) and reference lists of included studies. We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 5 July 2016. Selection criteria We included randomized controlled trials (RCTs) that compared AS versus artificial tears for treatment of adults with dry eye. Data collection and analysis Two review authors independently screened all titles and abstracts and assessed full-text reports of potentially eligible trials. Two review authors extracted data and assessed risk of bias and characteristics of included

  12. Patients' Perspectives on Their Dry Eye Disease.

    PubMed

    Crnej, Alja; Kheirkhah, Ahmad; Ren, Ai; Mullins, Andrew; Lavric, Alenka; Suri, Kunal; Hamrah, Pedram; Dana, Reza

    2016-10-01

    Although it has been known that patients' perspectives on their disease can significantly affect their level of functional disability as well as disease outcome, limited data are available on patients' perceptions of their dry eye disease (DED). The aim of this questionnaire-based study was to evaluate patients' perspectives on their DED. This cross-sectional study included 91 patients with DED. In addition to clinical evaluation, all patients completed a questionnaire to evaluate their perspectives on their DED. This included their satisfaction with understanding DED, their opinion on the easiness of following doctors' advice, their opinion on the effectiveness of the treatment, their satisfaction with the eye care, and their general outlook on DED. This study included 75 (82%) women and 16 men (18%) with a mean age of 57 ± 14 years who had been treated for DED for 5.2 ± 5.4 years. 93% of the patients were satisfied with their understanding of DED, and 76% found it easy to follow their doctors' advice for DED management. Furthermore, 95% thought that the DED treatment had been helpful and 95% were satisfied with their eye care for DED. Forty-eight percent expressed optimism regarding the long-term prospects of their DED. Although the majority of DED patients have positive perspectives on their disease, close to half report a lack of optimism regarding the long-term outlook for their condition. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Eating for Your Eyes

    ERIC Educational Resources Information Center

    Stastny, Sherri Nordstrom; Garden-Robinson, Julie

    2011-01-01

    An educational program targeting older adults was developed to increase knowledge regarding nutrition and eye health. With age, the chance for eye disease increases, so prevention is critical. The Eating for Your Eyes program has promoted behavior changes regarding eye health among the participants. This program is easily replicated and use is…

  14. An evaluation of image quality and accuracy of eye bank measurement of donor cornea endothelial cell density in the Specular Microscopy Ancillary Study.

    PubMed

    Lass, Jonathan H; Gal, Robin L; Ruedy, Katrina J; Benetz, Beth Ann; Beck, Roy W; Baratz, Keith H; Holland, Edward J; Kalajian, Andrea; Kollman, Craig; Manning, Francis J; Mannis, Mark J; McCoy, Kristen; Montoya, Monty; Stulting, Doyle; Xing, Dongyuan

    2005-03-01

    The Specular Microscopy Ancillary Study was designed to examine donor corneal endothelial specular image quality, compare the central endothelial cell density determined by eye banks with the endothelial cell density determined by a central specular microscopy reading center, and evaluate donor factors that may have an impact on specular image quality and endothelial cell density accuracy. Nonrandomized comparative trial. Endothelial specular images of donor corneas assigned in the Cornea Donor Study. Certified readers assessed donor image quality (analyzable from fair to excellent vs. unanalyzable) and determined the central endothelial cell density. Independent adjudication was performed if there was a difference in the quality of grading or if the endothelial cell density varied by > or =5.0% between readers. Average reading center-determined endothelial cell density was compared with the endothelial cell density determined by each eye bank. Evaluation of image quality and accuracy of endothelial cell density. Of 688 donor endothelial images submitted by 23 eye banks, 663 (96%) were analyzable (excellent, 40 [6%]; good, 302 [44%]; fair, 321 [47%]), and 25 (4%) were unanalyzable by reading center standards. In situ retrieval and greater epithelial exposure correlated with a higher image quality grading. The eye bank-determined endothelial cell density of 434 of the 663 (65%) analyzable images were within 10% of the endothelial cell density determined by the reading center, whereas 185 (28%) were more than 10% higher and 44 (7%) were more than 10% lower. Greater variation in endothelial cell density between the eye banks and the reading center was observed with shorter time of death to preservation, presence of an epithelial defect, folds in Descemet's membrane, lower image quality, and the use of fixed-frame or center method endothelial cell density analysis. Overall, donor endothelial specular image quality and accuracy of endothelial cell density determination

  15. Eye-closure-triggered paroxysmal activity and cognitive impairment: a case report.

    PubMed

    Termine, Cristiano; Rubboli, Guido; Veggiotti, Pierangelo

    2006-01-01

    To study the neuropsychological status of an epileptic patient presenting with epileptic activity triggered by eye closure in a 14-year follow-up period. The patient was studied at 12 and 26 years of age; during this period he underwent periodical clinical evaluations and EEG investigations; brain magnetic resonance imaging (MRI) was performed at 12 years of age. A neuropsychological assessment was carried out both at 12 years of age (T0) and at 26 years of age. At T0 and T1, neuropsychological tests (digits and words span, graphoestesia, reactions time to auditory stimuli, sentences repetition, words repetition, digital gnosis, backward counting [i.e.,100-0]) were performed during video-EEG monitoring either with eyes closed or with eyes open, to evaluate possible transitory effects related to ongoing epileptic activity. Moreover, at T0 the patient underwent Wechsler Intelligence Scale for Children-Revised, and at T1 to Wechsler Adult Intelligence Scale-Revised. EEG recordings showed continuous epileptic activity triggered by eye closure, disappearing only with eyes opening, both at T0 and T1 (in this latter case, anteriorly predominant). The results of neuropsychological assessment during eyes closed as compared to performances with eyes open did not show significant differences, at T0 as well as at T1. Wechsler Intelligence scales showed a deterioration of performances at T1 with respect to T0; in addition, at T1, attention and short-term memory abnormalities, impairment in facial recognition and block design, and defective results in Continuous Performance Test and Wisconsin Card Sorting Test were observed. Lack of differences between the results of neuropsychological tests performed with eyes closed as compared to the eyes open condition suggests that in our patient epileptic activity did not cause transitory cognitive abnormalities. Deterioration of Wechsler Intelligence Scales in the follow-up period might be interpreted as the result of a disruption of

  16. CON4EI: EpiOcular™ Eye Irritation Test (EpiOcular™ EIT) for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Kandarova, H; Letasiova, S; Adriaens, E; Guest, R; Willoughby, J A; Drzewiecka, A; Gruszka, K; Alépée, Nathalie; Verstraelen, Sandra; Van Rompay, An R

    2018-06-01

    Assessment of the acute eye irritation potential is part of the international regulatory requirements for testing of chemicals. The objective of the CON4EI project was to develop tiered testing strategies for eye irritation assessment. A set of 80 reference chemicals (38 liquids and 42 solids) was tested with eight different methods. Here, the results obtained with the EpiOcular™ Eye Irritation Test (EIT), adopted as OECD TG 492, are shown. The primary aim of this study was to evaluate of the performance of the test method to discriminate between chemicals not requiring classification for serious eye damage/eye irritancy (No Category) and chemicals requiring classification and labelling. In addition, the predictive capacity in terms of in vivo drivers of classification (i.e. corneal opacity, conjunctival redness and persistence at day 21) was investigated. EpiOcular™ EIT achieved a sensitivity of 97%, a specificity of 87% and accuracy of 95% and also confirmed its excellent reproducibility (100%) from the original validation. The assay was applicable to all chemical categories tested in this project and its performance was not limited to the particular driver of the classification. In addition to the existing prediction model for dichotomous categorization, a new prediction model for Cat 1 is suggested. Copyright © 2017. Published by Elsevier Ltd.

  17. Biometric measurements in highly myopic eyes.

    PubMed

    Shen, Peiyang; Zheng, Yingfeng; Ding, Xiaohu; Liu, Bin; Congdon, Nathan; Morgan, Ian; He, Mingguang

    2013-02-01

    To assess the repeatability and accuracy of optical biometry (Lenstar LS900 optical low-coherence reflectometry [OLCR] and IOLMaster partial coherence interferometry [PCI]) and applanation ultrasound biometry in highly myopic eyes. Division of Preventive Ophthalmology, Zhongshan Ophthalmic Center, Guangzhou, China. Comparative evaluation of diagnostic technology. Biometric measurements were taken in highly myopic subjects with a spherical equivalent (SE) of -6.00 diopters (D) or higher and an axial length (AL) longer than 25.0 mm. Measurements of AL and anterior chamber depth (ACD) obtained by OLCR were compared with those obtained by PCI and applanation A-scan ultrasound. Right eyes were analyzed. Repeatability was evaluated using the coefficient of variation (CoV) and agreement, using Bland-Altman analyses. The mean SE was -11.20 D ± 4.65 (SD). The CoVs for repeated AL measurements using OLCR, PCI, and applanation ultrasound were 0.06%, 0.07%, and 0.20%, respectively. The limits of agreement (LoA) for AL were 0.11 mm between OLCR and PCI, 1.01 mm between OLCR and applanation ultrasound, and 1.03 mm between PCI and ultrasound. The ACD values were 0.29 mm, 0.53 mm, and 0.51 mm, respectively. These repeatability and agreement results were comparable in eyes with extreme myopia (AL ≥ 27.0 mm) or posterior staphyloma. The mean radius of corneal curvature was similar between OLCR and PCI (7.66 ± 0.24 mm versus 7.64 ± 0.25 mm), with an LoA of 0.12 mm. Optical biometry provided more repeatable and precise measurements of biometric parameters, including AL and ACD, than applanation ultrasound biometry in highly myopic eyes. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Eye Cancer

    MedlinePlus

    Cancer of the eye is uncommon. It can affect the outer parts of the eye, such as the eyelid, which are made up ... and nerves. If the cancer starts inside the eyeball it's called intraocular cancer. The most common intraocular ...

  19. Choosing Wisely When It Comes to Eye Care: Antibiotics for Eye Injections

    MedlinePlus

    ... Antibiotics for eye injections; and Punctal plugs for dry eye . This is the fourth in a series of ... why patients and their ophthalmologists should discuss treating dry eye with punctal plugs only after other treatment options ...

  20. A Controlled, Randomized Double-Blind Study to Evaluate the Safety and Efficacy of Chitosan-N-Acetylcysteine for the Treatment of Dry Eye Syndrome.

    PubMed

    Schmidl, Doreen; Werkmeister, René; Kaya, Semira; Unterhuber, Angelika; Witkowska, Katarzyna J; Baumgartner, Renate; Höller, Sonja; O'Rourke, Maria; Peterson, Ward; Wolter, Annika; Prinz, Martin; Schmetterer, Leopold; Garhöfer, Gerhard

    2017-06-01

    This study was designed to evaluate the effect of chitosan-N-acetylcysteine (C-NAC) eye drops on tear film thickness (TFT) in patients with dry eye syndrome (DES). This was a controlled, randomized, double-blind clinical investigation with patients assigned to 2 cohorts. In Cohort I, 21 patients were randomized to receive 1 instillation of C-NAC eye drops in 1 eye and placebo (normal saline solution) in the contralateral eye. In Cohort II, 17 patients were randomized to receive C-NAC eye drops once (QD) or twice (BID) daily for 5 days. TFT was assessed with a custom-built ultrahigh-resolution optical coherence tomography system. In Cohort I, mean TFT increased from 3.9 ± 0.5 μm predose to 4.8 ± 1.1 μm 10 min postdose after treatment with C-NAC. The increase was significantly different from placebo over time (P < 0.0001) and remained stable until 24 h postdose. In Cohort II, TFT increased with QD and BID instillation, with no significant difference between regimens. In both groups, Ocular Surface Disease Index scores improved, fewer patients presented with corneal damage, and symptoms of ocular discomfort/conjunctival redness were reduced. A single instillation of C-NAC significantly increased mean TFT in patients with DES as early as 10 min after instillation and lasted for 24 h. The magnitude of the increase in TFT following a single instillation was comparable with that after instillation twice daily over 5 days. Corneal damage improved in >60% of patients. C-NAC could be a viable treatment option for DES.

  1. Spectacle-related eye injuries, spectacle-impact performance and eye protection.

    PubMed

    Hoskin, Annette K; Philip, Swetha; Dain, Stephen J; Mackey, David A

    2015-05-01

    The aim was to review the prevalence of spectacle-related ocular trauma and the performance of currently available spectacle materials and to identify the risk factors associated with spectacle-related ocular trauma. A literature review was conducted using Medline, Embase and Google with the keywords 'eyeglasses' OR 'spectacles' AND 'ocular injury' / 'eye injury'/ 'eye trauma' / 'ocular trauma'. Articles published prior to 1975 were excluded from this review because of advances in spectacle lens technology and Food and Drug Administration legislative changes requiring impact resistance of all prescription spectacle lenses in the United States. Six hundred and ninety-five individual ocular traumas, for which spectacles contributed to or were the main cause of injury, were identified in the literature. Eye injuries occurred when spectacles were worn in sports, in which medium- to high-impact energies were exerted from balls, racquets or bats and/or as a result of a collision with another player. Frame, lens design and product material choice were found to be associated with ocular injury, with polycarbonate lenses cited as the material of choice in the literature. International, regional and national standards for spectacle lenses had a wide range of impact requirements for prescription spectacle lenses, sports eye protection and occupational eye protection. Spectacle-related injury represents a small but preventable cause of ocular injury. With the increasing numbers of spectacle wearers and calls to spend more time outdoors to reduce myopia, spectacle wearers need to be made aware of the potential risks associated with wearing spectacles during medium- to high-risk activities. At particular risk are those prone to falls, the functionally one-eyed, those who have corneal thinning or have had previous eye surgery or injury. With increased understanding of specific risk factors, performance guidelines can be developed for prescription spectacle eye

  2. Degenerative effects in rat eyes after experimental ocular hypertension.

    PubMed

    Scarsella, G; Nebbioso, M; Stefanini, S; Pescosolido, N

    2012-10-08

    This study was used to evaluate the degenerative effects on the retina and eye-cup sections after experimental induction of acute ocular hypertension on animal models. In particular, vascular events were directly focused in this research in order to assess the vascular remodeling after transient ocular hypertension on rat models. After local anaesthesia by administration of eye drops of 0.4% oxibuprocaine, 16 male adult Wistar rats were injected in the anterior chamber of the right eye with 15 µL of methylcellulose (MTC) 2% in physiological solution. The morphology and the vessels of the retina and eye-cup sections were examined in animals sacrificed 72 h after induction of ocular hypertension. In retinal fluorescein angiographies (FAGs), by means of fluorescein isothiocyanate-coniugated dextran (FITC), the radial venules showed enlargements and increased branching, while the arterioles appeared focally thickened. The length and size of actually perfused vessels appeared increased in the whole superficial plexus. In eye-cup sections of MTC-injected animals, in deep plexus and connecting layer there was a bigger increase of vessels than in controls. Moreover, the immunolocalization of astrocytic marker glial fibrillary acidic protein (GFAP) revealed its increased expression in internal limiting membrane and ganglion cell layer, as well as its presence in Müller cells. Finally, the pro-angiogenic factor vascular endothelial growth factor (VEGF) was found to be especially expressed by neurones of ganglion cell layer, both in control and in MTC-injected eyes. The data obtained in this experimental model on the interactions among glia, vessels and neurons should be useful to evaluate if also in glaucomatous patients the activation of vessel-adjacent glial cells might play key roles in following neuronal dysfunction.

  3. Prevalence of dry eye syndrome and Sjogren's syndrome in patients with rheumatoid arthritis.

    PubMed

    Kosrirukvongs, Panida; Ngowyutagon, Panotsom; Pusuwan, Pawana; Koolvisoot, Ajchara; Nilganuwong, Surasak

    2012-04-01

    Rheumatoid arthritis has manifestations in various organs including ophthalmic involvement. The present study evaluates prevalence of dry eye and secondary Sjogren's syndrome using salivary scintigraphy which has not been used in previous reports. To evaluate the prevalence of secondary Sjogren's syndrome in patients with rheumatoid arthritis, including clinical characteristics and dry eye, compared with non-Sjogren's syndrome. Descriptive cross sectional study Sixty-one patients with rheumatoid arthritis were recruited at Siriraj Hospital during March 2009-September 2010 and filled in the questionnaires about dry eye for Ocular Surface Disease Index (OSDI) with a history taking of associated diseases, medications, duration of symptoms of dry eyes and dry mouth. The Schirmer I test without anesthesia, tear break-up time, rose bengal staining score, severity of keratitis and salivary scintigraphy were measured and analyzed. Prevalence of secondary Sjogren's syndrome and dry eye were 22.2% (95% CI 15.4 to 30.9) and 46.7% (95% CI 38.0 to 55.6), respectively. Dry eye interpreted from OSDI, Schirmer 1 test, tear break-up time and rose bengal staining was 16.4%, 46.7%, 82% and 3.3% respectively. Fifty-two percent of patients had a history of dry eye and dry mouth with mean duration 27.4 and 29.8 months, respectively. Superficial punctate keratitis and abnormal salivary scintigraphy were found in 58.2% and 77.8%. Duration of rheumatoid arthritis, erythrocyte sedimentation rate were not correlated with secondary Sjogren's syndrome. Dry eye from OSDI with secondary Sjogren's syndrome (33.3%) compared with non-Sjogren's syndrome (9.5%) was significant difference (p = 0.008). Adjusted odds ratio for secondary Sjogren's syndrome in OSDIL score > 25 was 13.8 (95% CI 2.6 to 73.8, p = 0.002) compared to OSDI score < 25. Awareness and detection of dry eye syndrome and secondary Sjogren's syndrome in rheumatoid arthritis was crucial for evaluation of their severity and proper

  4. Eye and orbit ultrasound

    MedlinePlus

    Echography - eye orbit; Ultrasound - eye orbit; Ocular ultrasonography; Orbital ultrasonography ... eye is numbed with medicine (anesthetic drops). The ultrasound wand (transducer) is placed against the front surface ...

  5. Noninvasive Dry Eye Assessment Using High-Technology Ophthalmic Examination Devices.

    PubMed

    Yamaguchi, Masahiko; Sakane, Yuri; Kamao, Tomoyuki; Zheng, Xiaodong; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-11-01

    Recently, the number of dry eye cases has dramatically increased. Thus, it is important that easy screening, exact diagnoses, and suitable treatments be available. We developed 3 original and noninvasive assessments for this disorder. First, a DR-1 dry eye monitor was used to determine the tear meniscus height quantitatively by capturing a tear meniscus digital image that was analyzed by Meniscus Processor software. The DR-1 meniscus height value significantly correlated with the fluorescein meniscus height (r = 0.06, Bland-Altman analysis). At a cutoff value of 0.22 mm, sensitivity of the dry eye diagnosis was 84.1% with 90.9% specificity. Second, the Tear Stability Analysis System was used to quantitatively measure tear film stability using a topographic modeling system corneal shape analysis device. Tear film stability was objectively and quantitatively evaluated every second during sustained eye openings. The Tear Stability Analysis System is currently installed in an RT-7000 autorefractometer and topographer to automate the diagnosis of dry eye. Third, the Ocular Surface Thermographer uses ophthalmic thermography for diagnosis. The decrease in ocular surface temperature in dry eyes was significantly greater than that in normal eyes (P < 0.001) at 10 seconds after eye opening. Decreased corneal temperature correlated significantly with the tear film breakup time (r = 0.572; P < 0.001). When changes in the ocular surface temperature of the cornea were used as indicators for dry eye, sensitivity was 0.83 and specificity was 0.80 after 10 seconds. This article describes the details and potential of these 3 noninvasive dry eye assessment systems.

  6. Dynamic torsional misalignment of eyes during laser in-situ keratomileusis.

    PubMed

    Shajari, Mehdi; Bühren, Jens; Kohnen, Thomas

    2016-05-01

    To determine the amount and characteristics of dynamic torsional misalignment of eyes during excimer ablation in laser in-situ keratomileusis (LASIK). Retrospective trial for evaluation of dynamic intraoperative torsional misalignment of 179 eyes that underwent LASIK for correction of myopia and/or astigmatism. Patients were treated with the Keracor 217z excimer laser implementing 25 Hz dynamic eye tracker ACE 100 (both Technolas Perfect Vision, Munich, Germany). From dynamic torsional misalignments, temporal power spectra were obtained by Fourier analysis up to a frequency of 12.5 Hz and an amplitude of ±15° from initial torsional status (limited by the tracking system). The f90, f95, and f99 criteria were defined as the frequency below which 90 %, 95 %, and 99 % of misalignments occur. A Wilcoxon rank sum test was performed to detect differences of f90, f95, and f99 in groups' gender, age, and eye (if both eyes underwent surgery at same day). Multiple regression analysis (MRA) was performed to evaluate possible preoperative predictors of f90, f95, and f99. Fourier analysis showed a dominance of high-frequency, low-power dynamic torsional misalignment. Mean f95 threshold of rotational movements was 4.89±2.12 Hz (median 4.54, ranging from 0.44 to 9.23 Hz). Wilcoxon rank sum test showed no differences in f90, f95, and f99 between groups' gender, age, and eye. MRA revealed age, gender, and optical zone as preoperative predictors on intraoperative f90, f95, and f99. Dynamic intraoperative torsional misalignments of eyes undergoing LASIK are dominated by low-frequency (slow), high-power (large) movements, with 95 % being slower than 4.89Hz regarding the spectrum analyzed (0-12.5Hz, ±15°). Movements can be predicted preoperatively by eye treated, patients' gender, and age in pre-LASIK diagnostics.

  7. Complications of cataract surgery in eyes filled with silicone oil.

    PubMed

    Kanclerz, Piotr; Grzybowski, Andrzej; Schwartz, Stephen G; Lipowski, Paweł

    2018-03-01

    The aim of the study was to evaluate complications of cataract surgery in eyes filled with silicone oil. This retrospective, noncomparative, consecutive case series analyzed medical files of patients with eyes filled with silicone oil undergoing cataract surgery. Phacoemulsification with posterior chamber intraocular lens implantation was conducted with or without concurrent silicone oil removal. In this study, 121 eyes of 120 patients were included. In 32 eyes (26.4%) with evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, silicone oil was removed prior to phacoemulsification through a pars plana incision and no cases of posterior capsular rupture occurred during the subsequent cataract surgery. In the remaining 89 eyes, phacoemulsification was performed with silicone oil in the vitreous cavity. In these eyes, the rate of posterior capsular rupture was 9/89 (10.1%) and the rate of silicone oil migration into the anterior chamber through an apparently intact posterior capsule was 5/89 (5.6%). In 94 eyes (77.7%), an intraocular lens was inserted into the capsular bag, in 3 eyes (2.5%) into the sulcus, and in 1 eye (0.8%) a transscleral suturing was performed. In this series, complications related to the silicone oil were not uncommon during cataract surgery. In the majority of patients without evident silicone oil microemulsification or silicone oil-associated open-angle glaucoma, cataract surgery and posterior chamber intraocular lens implantation were performed while leaving the silicone oil in place.

  8. Multimodal Imaging of the Normal Eye.

    PubMed

    Kawali, Ankush; Pichi, Francesco; Avadhani, Kavitha; Invernizzi, Alessandro; Hashimoto, Yuki; Mahendradas, Padmamalini

    2017-10-01

    Multimodal imaging is the concept of "bundling" images obtained from various imaging modalities, viz., fundus photograph, fundus autofluorescence imaging, infrared (IR) imaging, simultaneous fluorescein and indocyanine angiography, optical coherence tomography (OCT), and, more recently, OCT angiography. Each modality has its pros and cons as well as its limitations. Combination of multiple imaging techniques will overcome their individual weaknesses and give a comprehensive picture. Such approach helps in accurate localization of a lesion and understanding the pathology in posterior segment. It is important to know imaging of normal eye before one starts evaluating pathology. This article describes multimodal imaging modalities in detail and discusses healthy eye features as seen on various imaging modalities mentioned above.

  9. Eye Tracking Based Control System for Natural Human-Computer Interaction

    PubMed Central

    Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design. PMID:29403528

  10. Ocular blastomycosis in dogs: 73 cases, 108 eyes (1985-1993).

    PubMed

    Bloom, J D; Hamor, R E; Gerding, P A

    1996-10-01

    To evaluate clinical signs of ocular blastomycosis in dogs, to determine response of blastomycosis-infected eyes to treatment with systemically administered amphotericin B and ketoconazole, and to identify prognostic indicators of successful antifungal treatment. Retrospective study. 73 dogs. Medical records were reviewed for all dogs with confirmed blastomycosis and ocular disease seen at our hospital between 1985 and 1993. 6 eyes had anterior segment disease, 24 had posterior segment disease, and 78 had endophthalmitis. 40 eyes were treated with a combination of amphotericin B and ketoconazole, and 16 of the 40 responded favorably. However, 16 of the 24 eyes that were not severely affected responded favorably, but none of the 16 eyes that were severely affected did. Dogs with blastomycosis had posterior segment disease, without complete retinal separation, had a good prognosis for retaining vision. Results of histologic examination suggested that secondary glaucoma was a manifestation of endophthalmitis and was indicative of a grave prognosis for response to antifungal and antiglaucoma treatment.

  11. Eye Tracking Based Control System for Natural Human-Computer Interaction.

    PubMed

    Zhang, Xuebai; Liu, Xiaolong; Yuan, Shyan-Ming; Lin, Shu-Fan

    2017-01-01

    Eye movement can be regarded as a pivotal real-time input medium for human-computer communication, which is especially important for people with physical disability. In order to improve the reliability, mobility, and usability of eye tracking technique in user-computer dialogue, a novel eye control system with integrating both mouse and keyboard functions is proposed in this paper. The proposed system focuses on providing a simple and convenient interactive mode by only using user's eye. The usage flow of the proposed system is designed to perfectly follow human natural habits. Additionally, a magnifier module is proposed to allow the accurate operation. In the experiment, two interactive tasks with different difficulty (searching article and browsing multimedia web) were done to compare the proposed eye control tool with an existing system. The Technology Acceptance Model (TAM) measures are used to evaluate the perceived effectiveness of our system. It is demonstrated that the proposed system is very effective with regard to usability and interface design.

  12. New insights into the diagnosis and treatment of dry eye.

    PubMed

    Dogru, Murat; Tsubota, Kazuo

    2004-04-01

    Over the past decade, numerous advances have been made in relation to dry eye diagnostic markers, technologies, and treatment options. The mainstay of treatment of dry eye is the use of artificial tear solutions and punctum plugs. A goal is the development of agents that provide symptomatic treatment and, at the same time, improve ocular surface keratinization. It is the authors' opinion that the functional visual acuity tester and the new tear stability analysis system will be widely used to improve diagnosis and evaluate treatment outcomes in KCS. Advances in treatment will utilize anti-inflammatory agents, immune suppressants such as Cyclosporin A and FK-506, growth hormones, androgens, topical mucins and ocular surface stimulating drugs, like INS365. Although aqueous-deficient dry eye is most commonly not associated with Sjogren syndrome (SS), aqueous-deficient dry eye is often most severe in patients with SS; thus, this article focuses mainly on SS-associated dry eye.

  13. The Cost of Being Watched: Stroop Interference Increases under Concomitant Eye Contact

    ERIC Educational Resources Information Center

    Conty, Laurence; Gimmig, David; Belletier, Clement; George, Nathalie; Huguet, Pascal

    2010-01-01

    Current models in social neuroscience advance that eye contact may automatically recruit cognitive resources. Here, we directly tested this hypothesis by evaluating the distracting strength of eye contact on concurrent visual processing in the well-known Stroop's paradigm. As expected, participants showed stronger Stroop interference under…

  14. Dry Eye

    MedlinePlus

    ... the Meibomian glands. Autoimmune disorders such as Sjögren’s syndrome, lupus, scleroderma, and rheumatoid arthritis and other disorders such as diabetes, thyroid disorders, and Vitamin A deficiency are associated with dry eye. Women are more likely to develop dry eye. ...

  15. Intraocular lens design for treating high myopia based on individual eye model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  16. Fixational eye movement: a negligible source of dynamic aberration.

    PubMed

    Mecê, Pedro; Jarosz, Jessica; Conan, Jean-Marc; Petit, Cyril; Grieve, Kate; Paques, Michel; Meimon, Serge

    2018-02-01

    To evaluate the contribution of fixational eye movements to dynamic aberration, 50 healthy eyes were examined with an original custom-built Shack-Hartmann aberrometer, running at a temporal frequency of 236Hz, with 22 lenslets across a 5mm pupil, synchronized with a 236Hz pupil tracker. A comparison of the dynamic behavior of the first 21 Zernike modes (starting from defocus) with and without digital pupil stabilization, on a 3.4s sequence between blinks, showed that the contribution of fixational eye movements to dynamic aberration is negligible. Therefore we highlighted the fact that a pupil tracker coupled to an Adaptive Optics Ophthalmoscope is not essential to achieve diffraction-limited resolution.

  17. Cat-eye effect target recognition with single-pixel detectors

    NASA Astrophysics Data System (ADS)

    Jian, Weijian; Li, Li; Zhang, Xiaoyue

    2015-12-01

    A prototype of cat-eye effect target recognition with single-pixel detectors is proposed. Based on the framework of compressive sensing, it is possible to recognize cat-eye effect targets by projecting a series of known random patterns and measuring the backscattered light with three single-pixel detectors in different locations. The prototype only requires simpler, less expensive detectors and extends well beyond the visible spectrum. The simulations are accomplished to evaluate the feasibility of the proposed prototype. We compared our results to that obtained from conventional cat-eye effect target recognition methods using area array sensor. The experimental results show that this method is feasible and superior to the conventional method in dynamic and complicated backgrounds.

  18. Cellular proliferation and regeneration following tissue damage. Progress report. [Eyes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harding, C.V.

    1976-10-01

    Results are reported from a study of wound healing in tissues of the eye, particularly lens, cornea, and surrounding tissues. The reactions of these tissues to mechanical injuries, as well as injuries induced by chemotoxic agents were studied. It is postulated that a better understanding of the basic reactions of the eye to injurious agents may be of importance in the evaluation of potential environmental hazards.

  19. A new nonhuman primate model of severe dry eye.

    PubMed

    Qin, Yi; Tan, Xiaobo; Zhang, Yingnan; Jie, Ying; Labbe, Antoine; Pan, Zhiqiang

    2014-05-01

    The aim of this study was to establish a new rhesus monkey model of severe dry eye. A total of 8 rhesus monkeys were used for the study. Four monkeys had their main lacrimal gland and nictitating membrane surgically removed (group 1). Another 4 monkeys had a similar surgery with further application of 50% trichloroacetic acid on the bulbar conjunctiva (group 2). The ocular surface was evaluated before and after the surgery (1, 4, 8, 12, and 24 weeks) using Schirmer-1 test, corneal fluorescein staining, and the lissamine green test. Conjunctival impression cytology was also performed before and 24 weeks after the surgery. Finally, the cornea and the conjunctiva were evaluated using light microscopy. A significant decrease in tear secretion was observed in all operated eyes. Schirmer test data measured were ≤4 mm in all the operated eyes. Slit-lamp examination also revealed abnormal staining in all the operated eyes that remained stable until the end of the experiment. In group 2, corneal fluorescein staining and lissamine green test values were always ≥5 (max 12) and ≥4 (max 9), respectively. Impression cytology specimens of both the treated groups showed conjunctival squamous metaplasia and a decreased number of goblet cells. Under light microscopy, the corneal epithelium appeared irregular with edematous basal epithelial cells. The conjunctiva showed a decreased goblet cell density with infiltration of inflammatory cells. Complete removal of the principal lacrimal gland and nictitating membrane associated with the application of 50% trichloroacetic acid on the conjunctiva could induce severe dry eye in rhesus monkeys.

  20. Eye movements reflect and shape strategies in fraction comparison

    PubMed Central

    Ischebeck, Anja; Weilharter, Marina; Körner, Christof

    2016-01-01

    The comparison of fractions is a difficult task that can often be facilitated by separately comparing components (numerators and denominators) of the fractions—that is, by applying so-called component-based strategies. The usefulness of such strategies depends on the type of fraction pair to be compared. We investigated the temporal organization and the flexibility of strategy deployment in fraction comparison by evaluating sequences of eye movements in 20 young adults. We found that component-based strategies could account for the response times and the overall number of fixations observed for the different fraction pairs. The analysis of eye movement sequences showed that the initial eye movements in a trial were characterized by stereotypical scanning patterns indicative of an exploratory phase that served to establish the kind of fraction pair presented. Eye movements that followed this phase adapted to the particular type of fraction pair and indicated the deployment of specific comparison strategies. These results demonstrate that participants employ eye movements systematically to support strategy use in fraction comparison. Participants showed a remarkable flexibility to adapt to the most efficient strategy on a trial-by-trial basis. Our results confirm the value of eye movement measurements in the exploration of strategic adaptation in complex tasks. PMID:26039819

  1. Eye movements reflect and shape strategies in fraction comparison.

    PubMed

    Ischebeck, Anja; Weilharter, Marina; Körner, Christof

    2016-01-01

    The comparison of fractions is a difficult task that can often be facilitated by separately comparing components (numerators and denominators) of the fractions--that is, by applying so-called component-based strategies. The usefulness of such strategies depends on the type of fraction pair to be compared. We investigated the temporal organization and the flexibility of strategy deployment in fraction comparison by evaluating sequences of eye movements in 20 young adults. We found that component-based strategies could account for the response times and the overall number of fixations observed for the different fraction pairs. The analysis of eye movement sequences showed that the initial eye movements in a trial were characterized by stereotypical scanning patterns indicative of an exploratory phase that served to establish the kind of fraction pair presented. Eye movements that followed this phase adapted to the particular type of fraction pair and indicated the deployment of specific comparison strategies. These results demonstrate that participants employ eye movements systematically to support strategy use in fraction comparison. Participants showed a remarkable flexibility to adapt to the most efficient strategy on a trial-by-trial basis. Our results confirm the value of eye movement measurements in the exploration of strategic adaptation in complex tasks.

  2. 78 FR 52943 - Changes in Flood Hazard Determinations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ... 89015. North Carolina: Rowan Town of Granite The Honorable Mary Town Hall, 143 http:// October 17, 2013..... 370212 Quarry (12-04- S. Ponds, Mayor, North Salisbury www.ncfloodmaps.com/ 5555P). Town of Granite Avenue, Granite fhd.htm. Quarry, 143 North Quarry, NC 28072. Salisbury Avenue Granite Quarry, NC 28072...

  3. Legibility difference between e-books and paper books by using an eye tracker.

    PubMed

    Kim, Jung-Yong; Min, Seung-Nam; Subramaniyam, Murali; Cho, Young-Jin

    2014-01-01

    The aim of the study was to evaluate the difference in legibility between e-books and paper books by using an eye tracker. Eight male and eight female subjects free of eye disease participated in the experiment. The experiment was conducted using a 2 × 3 within-subject design. The book type (e-book, paper book) and font size (8 pt, 10 pt, 12 pt) were independent variables, and fixation duration time, saccade length, blink rate and subjective discomfort were dependent variables. In the results, all dependent variables showed that reading paper books provided a better experience than reading e-books did. These results indicate that the legibility of e-books needs further improvement, considering fixation duration time, saccade movement, eye fatigue, device and so on. This study evaluated the legibility difference between e-books and paper books from the viewpoint of readability, eye fatigue and subjective discomfort by using an eye tracker. The results showed that paper books provided a better experience than e-books. This indicates that the readability of e-books needs further improvement in relation to paper books.

  4. Fear of eyes: triadic relation among social anxiety, trypophobia, and discomfort for eye cluster.

    PubMed

    Chaya, Kengo; Xue, Yuting; Uto, Yusuke; Yao, Qirui; Yamada, Yuki

    2016-01-01

    Imagine you are being gazed at by multiple individuals simultaneously. Is the provoked anxiety a learned social-specific response or related to a pathological disorder known as trypophobia? A previous study revealed that spectral properties of images induced aversive reactions in observers with trypophobia. However, it is not clear whether individual differences such as social anxiety traits are related to the discomfort associated with trypophobic images. To investigate this issue, we conducted two experiments with social anxiety and trypophobia and images of eyes and faces. In Experiment 1, participants completed a social anxiety scale and trypophobia questionnaire before evaluation of the discomfort experienced upon exposure to pictures of eye. The results showed that social anxiety had a significant indirect effect on the discomfort associated with the eye clusters, and that the effect was mediated by trypophobia. Experiment 2 replicated Experiment 1 using images of human face. The results showed that, as in Experiment 1, a significant mediation effect of trypophobia was obtained, although the relationship between social anxiety and the discomfort rating was stronger than in Experiment 1. Our findings suggest that both social anxiety and trypophobia contribute to the induction of discomfort when one is gazed at by many people.

  5. Fear of eyes: triadic relation among social anxiety, trypophobia, and discomfort for eye cluster

    PubMed Central

    Xue, Yuting; Uto, Yusuke; Yao, Qirui; Yamada, Yuki

    2016-01-01

    Imagine you are being gazed at by multiple individuals simultaneously. Is the provoked anxiety a learned social-specific response or related to a pathological disorder known as trypophobia? A previous study revealed that spectral properties of images induced aversive reactions in observers with trypophobia. However, it is not clear whether individual differences such as social anxiety traits are related to the discomfort associated with trypophobic images. To investigate this issue, we conducted two experiments with social anxiety and trypophobia and images of eyes and faces. In Experiment 1, participants completed a social anxiety scale and trypophobia questionnaire before evaluation of the discomfort experienced upon exposure to pictures of eye. The results showed that social anxiety had a significant indirect effect on the discomfort associated with the eye clusters, and that the effect was mediated by trypophobia. Experiment 2 replicated Experiment 1 using images of human face. The results showed that, as in Experiment 1, a significant mediation effect of trypophobia was obtained, although the relationship between social anxiety and the discomfort rating was stronger than in Experiment 1. Our findings suggest that both social anxiety and trypophobia contribute to the induction of discomfort when one is gazed at by many people. PMID:27168967

  6. An Evaluation of Educational Neurological Eye Movement Disorder Videos Posted on Internet Video Sharing Sites.

    PubMed

    Hickman, Simon J

    2016-03-01

    Internet video sharing sites allow the free dissemination of educational material. This study investigated the quality and educational content of videos of eye movement disorders posted on such sites. Educational neurological eye movement videos were identified by entering the titles of the eye movement abnormality into the search boxes of the video sharing sites. Also, suggested links were followed from each video. The number of views, likes, and dislikes for each video were recorded. The videos were then rated for their picture and sound quality. Their educational value was assessed according to whether the video included a description of the eye movement abnormality, the anatomical location of the lesion (if appropriate), and the underlying diagnosis. Three hundred fifty-four of these videos were found on YouTube and Vimeo. There was a mean of 6,443 views per video (range, 1-195,957). One hundred nineteen (33.6%) had no form of commentary about the eye movement disorder shown apart from the title. Forty-seven (13.3%) contained errors in the title or in the text. Eighty (22.6%) had excellent educational value by describing the eye movement abnormality, the anatomical location of the lesion, and the underlying diagnosis. Of these, 30 also had good picture and sound quality. The videos with excellent educational value had a mean of 9.84 "likes" per video compared with 2.37 for those videos without a commentary (P < 0.001). The videos that combined excellent educational value with good picture and sound quality had a mean of 10.23 "likes" per video (P = 0.004 vs videos with no commentary). There was no significant difference in the mean number of "dislikes" between those videos that had no commentary or which contained errors and those with excellent educational value. There are a large number of eye movement videos freely available on these sites; however, due to the lack of peer review, a significant number have poor educational value due to having no commentary

  7. In the eye of the beholder: eye contact increases resistance to persuasion.

    PubMed

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  8. Before your very eyes: the value and limitations of eye tracking in medical education.

    PubMed

    Kok, Ellen M; Jarodzka, Halszka

    2017-01-01

    Medicine is a highly visual discipline. Physicians from many specialties constantly use visual information in diagnosis and treatment. However, they are often unable to explain how they use this information. Consequently, it is unclear how to train medical students in this visual processing. Eye tracking is a research technique that may offer answers to these open questions, as it enables researchers to investigate such visual processes directly by measuring eye movements. This may help researchers understand the processes that support or hinder a particular learning outcome. In this article, we clarify the value and limitations of eye tracking for medical education researchers. For example, eye tracking can clarify how experience with medical images mediates diagnostic performance and how students engage with learning materials. Furthermore, eye tracking can also be used directly for training purposes by displaying eye movements of experts in medical images. Eye movements reflect cognitive processes, but cognitive processes cannot be directly inferred from eye-tracking data. In order to interpret eye-tracking data properly, theoretical models must always be the basis for designing experiments as well as for analysing and interpreting eye-tracking data. The interpretation of eye-tracking data is further supported by sound experimental design and methodological triangulation. © 2016 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  9. Eye movement analysis for activity recognition using electrooculography.

    PubMed

    Bulling, Andreas; Ward, Jamie A; Gellersen, Hans; Tröster, Gerhard

    2011-04-01

    In this work, we investigate eye movement analysis as a new sensing modality for activity recognition. Eye movement data were recorded using an electrooculography (EOG) system. We first describe and evaluate algorithms for detecting three eye movement characteristics from EOG signals-saccades, fixations, and blinks-and propose a method for assessing repetitive patterns of eye movements. We then devise 90 different features based on these characteristics and select a subset of them using minimum redundancy maximum relevance (mRMR) feature selection. We validate the method using an eight participant study in an office environment using an example set of five activity classes: copying a text, reading a printed paper, taking handwritten notes, watching a video, and browsing the Web. We also include periods with no specific activity (the NULL class). Using a support vector machine (SVM) classifier and person-independent (leave-one-person-out) training, we obtain an average precision of 76.1 percent and recall of 70.5 percent over all classes and participants. The work demonstrates the promise of eye-based activity recognition (EAR) and opens up discussion on the wider applicability of EAR to other activities that are difficult, or even impossible, to detect using common sensing modalities.

  10. Indian Soldiers Need Eye Protection.

    PubMed

    Jha, Kirti Nath

    2017-02-01

    Combat-related eye injuries entail enormous financial, social and psychological cost. Military Combat Eye Protection (MCEP) decreases both the incidence and severity of eye injuries. Experts have recognised the need for MCEP for Indian soldiers. We aim to review the combat-related eye injuries and combat eye protection among the Indian soldiers. Global practices of MCEP are also reviewed. We also aim to offer our recommendations for Indian soldiers. We carried out Medline search for combat-related eye injuries and MCEP and separately searched for eye injuries among Indian soldiers during war and other operations. We present the findings as results. Recommendations are based on the opinions of the experts. Combat-related eye injuries increased from 3% of injured in the 1965 Indo-Pakistan War to 4.8% in 1971 war. During peace-keeping operations in Sri Lanka (1987-89) eye injuries increased to 10.5% of the injured. Statistics on eye injuries during counterinsurgency operations are not available. MCEP have shown reduction in eye injuries, and thus MCEP forms a part of personal equipment of the soldiers in developed countries. Indian soldiers do not have provision of MCEP. Combat-related eye injuries among Indian Army soldiers have been increasing. Data on eye injuries during counterinsurgency operations are not available. Indian soldiers do not have provision of MCEP. Provision of MCEP is therefore desirable. Awareness program among the commanders and the soldiers shall result in attitudinal changes and increased compliance.

  11. Indian Soldiers Need Eye Protection

    PubMed Central

    2017-01-01

    Combat-related eye injuries entail enormous financial, social and psychological cost. Military Combat Eye Protection (MCEP) decreases both the incidence and severity of eye injuries. Experts have recognised the need for MCEP for Indian soldiers. We aim to review the combat-related eye injuries and combat eye protection among the Indian soldiers. Global practices of MCEP are also reviewed. We also aim to offer our recommendations for Indian soldiers. We carried out Medline search for combat-related eye injuries and MCEP and separately searched for eye injuries among Indian soldiers during war and other operations. We present the findings as results. Recommendations are based on the opinions of the experts. Combat-related eye injuries increased from 3% of injured in the 1965 Indo-Pakistan War to 4.8% in 1971 war. During peace-keeping operations in Sri Lanka (1987-89) eye injuries increased to 10.5% of the injured. Statistics on eye injuries during counterinsurgency operations are not available. MCEP have shown reduction in eye injuries, and thus MCEP forms a part of personal equipment of the soldiers in developed countries. Indian soldiers do not have provision of MCEP. Combat-related eye injuries among Indian Army soldiers have been increasing. Data on eye injuries during counterinsurgency operations are not available. Indian soldiers do not have provision of MCEP. Provision of MCEP is therefore desirable. Awareness program among the commanders and the soldiers shall result in attitudinal changes and increased compliance. PMID:28384904

  12. Promoting effect of borneol on the permeability of puerarin eye drops and timolol maleate eye drops through the cornea in vitro.

    PubMed

    Wu, Chun-jie; Huang, Qin-wan; Qi, Hong-yi; Guo, Ping; Hou, Shi-xiang

    2006-09-01

    Studies on the influence of borneol on the penetration of puerarin eye drops and timolol maleate eye drops through the cornea, and evaluation of the ocular irritability were conducted to provide a theoretical basis for the application of borneol in enhancing corneal permeability. The cornea penetrative experiment in vitro was conducted to observe the quantitative change of puerarin and timolol maleate penetrated through the cornea after administering different dosages of borneol. The corneal hydration level and blinking frequency were recorded as irritability indexes in vitro and in vivo. The steady-flow J of high, middle and low dosage groups of puerarin eye drops with borneol were increased by 49%, 32%, 5% respectively, and permeability parameter Kp increased by 49%, 32%, 5% respectively, as compared to that of the control group. The steady-flow J of high dosage group of timolol maleate eye drops with borneol was increased by 5%; middle and low dosage groups with borneol were decreased by 6%, 3% respectively. The permeability parameter Kp of high dosage group increased by 5%, while middle and low dosage groups with borneol were decreased by 6%, 3% respectively, as compared to that of the control group. Evaluation showed no ocular irritability caused by borneol. The results of this study suggest that the promoting effect of borneol on the permeability of drugs through the cornea in vitro is selective, which indicates that borneol has the potential to be used as an ophthalmic penetration enhancer.

  13. Melanoma of the eye

    MedlinePlus

    ... eye, including the: Choroid Ciliary body Conjunctiva Eyelid Iris Orbit The choroid layer is the most likely ... any of the following: Bulging eyes Change in iris color Poor vision in one eye Red, painful ...

  14. What Is Dry Eye?

    MedlinePlus Videos and Cool Tools

    ... Member Services Advocacy Foundation About Subspecialties & More Eye Health Home Annual Meeting Clinical Education Practice Management Member ... Center Redmond Ethics Center Global Ophthalmology Guide Eye Health Find an Ophthalmologist Academy Store Eye Health A- ...

  15. Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes.

    PubMed

    Werner, Liliana; Pandey, Suresh K; Izak, Andrea M; Vargas, Luis G; Trivedi, Rupal H; Apple, David J; Mamalis, Nick

    2004-05-01

    To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.

  16. Laser photocoagulation - eye

    MedlinePlus

    Laser coagulation; Laser eye surgery; Photocoagulation; Laser photocoagulation - diabetic eye disease; Laser photocoagulation - diabetic retinopathy; Focal photocoagulation; Scatter (or pan retinal) photocoagulation; Proliferative ...

  17. Creation of nano eye-drops and effective drug delivery to the interior of the eye

    NASA Astrophysics Data System (ADS)

    Ikuta, Yoshikazu; Aoyagi, Shigenobu; Tanaka, Yuji; Sato, Kota; Inada, Satoshi; Koseki, Yoshitaka; Onodera, Tsunenobu; Oikawa, Hidetoshi; Kasai, Hitoshi

    2017-03-01

    Nano eye-drops are a new type of ophthalmic treatment with increased potency and reduced side effects. Compounds in conventional eye-drops barely penetrate into the eye because the cornea, located at the surface of eye, has a strong barrier function for preventing invasion of hydrophilic or large-sized materials from the outside. In this work, we describe the utility of nano eye-drops utilising brinzolamide, a commercially available glaucoma treatment drug, as a target compound. Fabrication of the nanoparticles of brinzolamide prodrug increases the eye penetration rate and results in high drug efficacy, compared with that of commercially available brinzolamide eye-drops formulated as micro-sized structures. In addition, the resulting nano eye-drops were not toxic to the corneal epithelium after repeated administration for 1 week. The nano eye-drops may have applications as a next-generation ophthalmic treatment.

  18. Combination Therapy of Intense Pulsed Light Therapy and Meibomian Gland Expression (IPL/MGX) Can Improve Dry Eye Symptoms and Meibomian Gland Function in Patients With Refractory Dry Eye: A Retrospective Analysis.

    PubMed

    Vegunta, Sravanthi; Patel, Dharmendra; Shen, Joanne F

    2016-03-01

    To assess the improvement in meibomian gland function and dry eye symptoms in patients with refractory dry eye treated with a combination therapy of intense pulsed light (IPL) and meibomian gland expression (MGX). Medical records of 81 consecutive patients with dry eye treated with serial IPL/MGX were retrospectively examined to determine the outcome. All patients had a minimum of 6 months of follow-up after the first IPL/MGX treatment. Patients typically received 1 to 4 IPL treatments spaced 4 to 6 weeks apart. Each IPL session included MGX. Thirty-five charts had complete data for inclusion in analysis. We reviewed demographics, ocular histories, Standard Patient Evaluation of Eye Dryness 2 (SPEED2) symptom survey scores, slit-lamp examinations, and meibomian gland evaluations (MGE) at baseline and at each visit before IPL/MGX treatments. The paired t test showed a significant (P < 0.0001) decrease in SPEED2 with IPL/MGX therapy. Of the 35 patients, 8 (23%) had a ≥50% decrease in SPEED2, 23 (66%) had a 1% to 49% decrease in SPEED2, 1 (3%) had no change in SPEED2, and 3 (9%) had an increase in SPEED2. The Paired t test showed a significant increase in MGE in the left eye but not in the right eye (OD P = 0.163 and OS P = 0.0002). Thirteen patients (37%) had improved MGE bilaterally. Eight patients (23%) had either a decrease in MGE bilaterally or a decrease in 1 eye with no change in the other eye. This retrospective analysis shows that the combination of IPL and MGX can significantly improve dry eye symptoms (in 89% of patients) and meibomian gland function (in 77% of patients in at least 1 eye).

  19. A pilot study to evaluate incorporating eye care for children into reproductive and child health services in Dar-es-Salaam, Tanzania: a historical comparison study

    PubMed Central

    2014-01-01

    Background Many blinding eye conditions of childhood are preventable or treatable, particularly in developing countries. However, primary eye care (PEC) for children is poorly developed, leading to unnecessary visual loss. Activities for control by health workers entail interventions for systemic conditions (measles, vitamin A deficiency), identification and referral of children with sight threatening conditions and health education for caregivers. This pilot study evaluated integrating a package of activities to promote child eye health into Reproductive and Child Health (RCH) services in Dar-es-Salaam, Tanzania. Methods Design: historical comparison study. Fifteen Clinical Officers and 15 nurses in 15 randomly selected RCH clinics were trained in PEC for children in July 2010. They were given educational materials (poster and manual) and their supervisors were orientated. Knowledge and practices were assessed before and 3 weeks after training. One year later their knowledge and practices were compared with a different group of 15 Clinical Officers and 15 nurses who had not been trained. Results Before training staff had insufficient knowledge to identify, treat and refer children with eye diseases, even conjunctivitis. Some recommended harmful practices or did not know that cataract requires urgent referral. Eye examination, vitamin A supplementation of mothers after delivery and cleaning the eyes at birth with instillation of antibiotics (Crede’s prophylaxis) were not routine, and there were no eye-specific educational materials. Three weeks after training several clinics delivering babies started Crede’s prophylaxis, vitamin A supplementation of women after delivery increased from 83.7% to 100%, and all staff included eye conditions in health education sessions. At one year, trained staff were more likely to correctly describe, diagnose and treat conjunctivitis (z=2.34, p=0.04)(30%-vs-60.7%). Mystery mothers observed health education sessions in 7/10 RCH

  20. Vitrectomy outcomes in eyes with diabetic macular edema and vitreomacular traction.

    PubMed

    Haller, Julia A; Qin, Haijing; Apte, Rajendra S; Beck, Roy R; Bressler, Neil M; Browning, David J; Danis, Ronald P; Glassman, Adam R; Googe, Joseph M; Kollman, Craig; Lauer, Andreas K; Peters, Mark A; Stockman, Margaret E

    2010-06-01

    To evaluate vitrectomy for diabetic macular edema (DME) in eyes with at least moderate vision loss and vitreomacular traction. Prospective cohort study. The primary cohort included 87 eyes with DME and vitreomacular traction based on investigator's evaluation, visual acuity 20/63-20/400, optical coherence tomography (OCT) central subfield >300 microns and no concomitant cataract extraction at the time of vitrectomy. Surgery was performed according to the investigator's usual routine. Follow-up visits were performed after 3 months, 6 months (primary end point), and 1 year. Visual acuity, OCT retinal thickening, and operative complications. At baseline, median visual acuity in the 87 eyes was 20/100 and median OCT thickness was 491 microns. During vitrectomy, additional procedures included epiretinal membrane peeling in 61%, internal limiting membrane peeling in 54%, panretinal photocoagulation in 40%, and injection of corticosteroids at the close of the procedure in 64%. At 6 months, median OCT central subfield thickness decreased by 160 microns, with 43% having central subfield thickness <250 microns and 68% having at least a 50% reduction in thickening. Visual acuity improved by > or =10 letters in 38% (95% confidence interval, 28%-49%) and deteriorated by > or =10 letters in 22% (95% confidence interval, 13%-31%). Postoperative complications through 6 months included vitreous hemorrhage (5 eyes), elevated intraocular pressure requiring treatment (7 eyes), retinal detachment (3 eyes), and endophthalmitis (1 eye). Few changes in results were noted between 6 months and 1 year. After vitrectomy performed for DME and vitreomacular traction, retinal thickening was reduced in most eyes. Between 28% and 49% of eyes with characteristics similar to those included in this study are likely to have improvement of visual acuity, whereas between 13% and 31% are likely to have worsening. The operative complication rate is low and similar to what has been reported for this

  1. Anti-inflammatory and Antihistaminic Study of a Unani Eye Drop Formulation.

    PubMed

    Abdul, Latif; Abdul, Razique; Sukul, R R; Nazish, Siddiqui

    2010-01-01

    The Unani eye drop is an ophthalmic formulation prepared for its beneficial effects in the inflammatory and allergic conditions of the eyes. In the present study, the Unani eye drop formulation was prepared and investigated for its anti-inflammatory and antihistaminic activity, using in vivo and in vitro experimental models respectively. The Unani eye drop formulation exhibited significant anti-inflammatory activity in turpentine liniment-induced ocular inflammation in rabbits. The preparation also showed antihistaminic activity in isolated guinea-pig ileum. The anti-inflammatory and antihistaminic activity of eye drop may be due to presence of active ingredients in the formulation. Although there are many drugs in Unani repository which are mentioned in classical books or used in Unani clinical practice effectively in treatment of eye diseases by various Unani physicians. Inspite of the availability of vast literature, there is a dearth of commercial Unani ocular preparations. So, keeping this in mind, the eye drop formulation was prepared and its anti-inflammatory and antihistaminic activity was carried out in animal models. Thus, in view of the importance of alternative anti-inflammatory and antiallergic drugs, it becomes imperative to bring these indigenous drugs to the front foot and evaluate their activities.

  2. Depth-estimation-enabled compound eyes

    NASA Astrophysics Data System (ADS)

    Lee, Woong-Bi; Lee, Heung-No

    2018-04-01

    Most animals that have compound eyes determine object distances by using monocular cues, especially motion parallax. In artificial compound eye imaging systems inspired by natural compound eyes, object depths are typically estimated by measuring optic flow; however, this requires mechanical movement of the compound eyes or additional acquisition time. In this paper, we propose a method for estimating object depths in a monocular compound eye imaging system based on the computational compound eye (COMPU-EYE) framework. In the COMPU-EYE system, acceptance angles are considerably larger than interommatidial angles, causing overlap between the ommatidial receptive fields. In the proposed depth estimation technique, the disparities between these receptive fields are used to determine object distances. We demonstrate that the proposed depth estimation technique can estimate the distances of multiple objects.

  3. Androgen deficiency and dry eye syndrome in the aging male.

    PubMed

    Azcarate, Patrick M; Venincasa, Vincent D; Feuer, William; Stanczyk, Frank; Schally, Andrew V; Galor, Anat

    2014-07-03

    To evaluate the relationship between androgen levels and subjective and objective measures of dry eye syndrome (DES). A total of 263 male patients from the Miami Veterans Affairs Medical Center eye clinic aged ≥50 were recruited for this prospective cross-sectional study. Patients completed Dry Eye Questionnaire 5, underwent tear film evaluation, and had serum androgen levels measured. The correlations between androgen levels, DES composite scores, DES symptoms, and global, lipid, and aqueous tear film parameters were evaluated. Two hundred sixty-three patients with a mean age of 69 (50-95) were examined. There was no linear association between composite DES scores (generated using latent class analysis) and androgen levels. However, eyes with high DES scores (0.95-1.0) had higher levels of sex hormone-binding globulin (P = 0.03) and lower levels of dehydroepiandrosterone sulfate (DHEAS) (P = 0.02), androstenedione (A) (P = 0.02), and androstane-3α,17β-diol glucuronide (P = 0.03) compared to eyes with intermediate (0.05-0.95) or low (0-0.05) scores. There were no strong correlations between tear film measures and androgen levels. Regarding global parameters, a weak inverse correlation was found between corneal staining and A (r = -0.17, P = 0.009). For lipid parameters, a weak correlation existed between tear breakup time (TBUT) and A (r = 0.15, P = 0.02). When considering aqueous and lipid deficiency independently, the association between TBUT and A existed only with aqueous tear deficiency (r = 0.66, P = 0.002). Regarding aqueous parameters, a weak correlation existed between Schirmer test and DHEAS (r = 0.13, P = 0.047) and A (r = 0.21, P = 0.001). There was a weak correlation between higher levels of androstenedione and healthier global, lipid, and aqueous tear film parameters. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  4. Tear production and intraocular pressure in canine eyes with corneal ulceration

    PubMed Central

    Williams, David L.; Burg, Philippa

    2017-01-01

    This study aimed to evaluate changes in lacrimation and intraocular pressure (IOP) in dogs with unilateral corneal ulceration using the Schirmer tear test (STT) and rebound (TonoVet®) tonometry. IOP and STT values were recorded in both ulcerated and non-ulcerated (control) eyes of 100 dogs diagnosed with unilateral corneal ulceration. Dogs presented with other ocular conditions as their primary complaint were excluded from this study. The mean ± standard deviation for STT values in the ulcerated and control eyes were 20.2±4.6 mm/min and 16.7±3.5 mm/min respectively. The mean ± standard deviation for IOP in the ulcerated and control eyes were 11.9±3.1 mmHg and 16.7±2.6 mmHg respectively. STT values were significantly higher (p<0.000001) in the ulcerated eye compared to the control eye while IOP was significantly lower (p<0.0001). There is an increase in lacrimation and a decrease in IOP in canine eyes with corneal ulceration. The higher tear production in ulcerated eyes shows the importance of measuring STT in both eyes in cases of corneal ulceration, since this increased lacrimation may mask an underlying keratoconjunctivitis sicca only evident in the contralateral eye. The lower IOP in ulcerated eyes is likely to relate to mild uveitic change in the ulcerated eye with a concomitant increase in uveoscleral aqueous drainage. While these changes in tear production and IOP in ulcerated eyes are widely recognised in both human and veterinary ophthalmology, it appears that this is the first controlled documented report of these changes in a large number of individuals. PMID:28616393

  5. Pioneers of eye movement research

    PubMed Central

    Wade, Nicholas J

    2010-01-01

    Recent advances in the technology affording eye movement recordings carry the risk of neglecting past achievements. Without the assistance of this modern armoury, great strides were made in describing the ways the eyes move. For Aristotle the fundamental features of eye movements were binocular, and he described the combined functions of the eyes. This was later given support using simple procedures like placing a finger over the eyelid of the closed eye and culminated in Hering's law of equal innervation. However, the overriding concern in the 19th century was with eye position rather than eye movements. Appreciating discontinuities of eye movements arose from studies of vertigo. The characteristics of nystagmus were recorded before those of saccades and fixations. Eye movements during reading were described by Hering and by Lamare in 1879; both used similar techniques of listening to sounds made during contractions of the extraocular muscles. Photographic records of eye movements during reading were made by Dodge early in the 20th century, and this stimulated research using a wider array of patterns. In the mid-20th century attention shifted to the stability of the eyes during fixation, with the emphasis on involuntary movements. The contributions of pioneers from Aristotle to Yarbus are outlined. PMID:23396982

  6. The CTFA Evaluation of Alternatives Program: an evaluation of in vitro alternatives to the Draize primary eye irritation test. (Phase III) surfactant-based formulations.

    PubMed

    Gettings, S D; Lordo, R A; Hintze, K L; Bagley, D M; Casterton, P L; Chudkowski, M; Curren, R D; Demetrulias, J L; Dipasquale, L C; Earl, L K; Feder, P I; Galli, C L; Glaza, S M; Gordon, V C; Janus, J; Kurtz, P J; Marenus, K D; Moral, J; Pape, W J; Renskers, K J; Rheins, L A; Roddy, M T; Rozen, M G; Tedeschi, J P; Zyracki, J

    1996-01-01

    The CTFA Evaluation of Alternatives Program is an evaluation of the relationship between data from the Draize primary eye irritation test and comparable data from a selection of promising in vitro eye irritation tests. In Phase III, data from the Draize test and 41 in vitro endpoints on 25 representative surfactant-based personal care formulations were compared. As in Phase I and Phase II, regression modelling of the relationship between maximum average Draize score (MAS) and in vitro endpoint was the primary approach adopted for evaluating in vitro assay performance. The degree of confidence in prediction of MAS for a given in vitro endpoint is quantified in terms of the relative widths of prediction intervals constructed about the fitted regression curve. Prediction intervals reflect not only the error attributed to the model but also the material-specific components of variation in both the Draize and the in vitro assays. Among the in vitro assays selected for regression modeling in Phase III, the relationship between MAS and in vitro score was relatively well defined. The prediction bounds on MAS were most narrow for materials at the lower or upper end of the effective irritation range (MAS = 0-45), where variability in MAS was smallest. This, the confidence with which the MAS of surfactant-based formulations is predicted is greatest when MAS approaches zero or when MAS approaches 45 (no comment is made on prediction of MAS > 45 since extrapolation beyond the range of observed data is not possible). No single in vitro endpoint was found to exhibit relative superiority with regard to prediction of MAS. Variability associated with Draize test outcome (e.g. in MAS values) must be considered in any future comparisons of in vivo and in vitro test results if the purpose is to predict in vivo response using in vitro data.

  7. Efficacy of a new topical cationic emulsion of cyclosporine A on dry eye clinical signs in an experimental mouse model of dry eye.

    PubMed

    Daull, Philippe; Feraille, Laurence; Barabino, Stefano; Cimbolini, Nicolas; Antonelli, Sophie; Mauro, Virgine; Garrigue, Jean-Sébastien

    2016-12-01

    Dry eye disease (DED) is a complex, multifactorial pathology characterized by corneal epithelium lesions and inflammation. The aim of the present study was to evaluate the efficacy of a cationic emulsion of cyclosporine A (CsA) in a mouse model that mimics severe dry eye. Eight to 12-week-old female C57BL/6N mice with tail patches of scopolamine were housed in controlled environment chambers to induce dry eye. At day three, following dry eye confirmation by corneal fluorescein staining (CFS, score 0-15) and phenol red thread (PRT) lacrimation test, the mice (n = 10/gp) were either treated 3 times a day in both eyes with drug-free cationic emulsion, a 0.1% CsA cationic emulsion, or 1% methylprednisolone (positive control), or non-treated. Aqueous tear production and CFS scores were evaluated at baseline and throughout the treatment period. The lacrimation test confirmed the scopolamine-induced decrease in aqueous production by the lacrimal gland. A reduction of 59% in induced-CFS was observed following topical treatment with 0.1% CsA. The beneficial effect of the cationic emulsion vehicle itself on keratitis was also clearly evidenced by its better performance over 1% methylprednisolone, -36%, vs. -28% on the CFS scores, respectively. This study indicates that the cationic emulsion of CsA (0.1%) was a very effective formulation for the management of corneal epithelium lesions in a severe DED mouse model. In addition, it performed better than a potent glucocorticosteroid (1% methylprednisolone). This cationic emulsion of CsA (0.1%), combining CsA and a tear film oriented therapy (TFOT), i.e. with vehicle properties that mechanically stabilize the tear film, represents a promising new treatment strategy for the management of the signs of dry eye. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Comparative Evaluation of Silicone Hydrogel Contact Lenses and Autologous Serum for Management of Sjögren Syndrome-Associated Dry Eye.

    PubMed

    Li, Jinyang; Zhang, Xiahua; Zheng, Qinxiang; Zhu, Yirui; Wang, Hui; Ma, Huixiang; Jhanji, Vishal; Chen, Wei

    2015-09-01

    To comparatively evaluate the efficacy of a bandage contact lens (BCL) and autologous serum (AS) eye drops in the management of severe dry eye caused by Sjögren syndrome (SS). In this prospective randomized study, 40 patients with SS were enrolled. Patients were divided into 2 treatment groups: BCL and AS. A total of 37 patients were included, 18 patients (35 eyes) in the AS group and 19 patients (36 eyes) in the BCL group. At the end of 6 weeks, the best-corrected visual acuity improved significantly in the BCL group (0.5 ± 0.3 vs. 0.3 ± 0.2, P = 0.003) but not in the AS group (0.4 ± 0.3 vs. 0.3 ± 0.3, P = 0.11). The best-corrected visual acuity remained stable up to 6 weeks after discontinuation of the BCL (0.5 ± 0.3 vs. 0.4 ± 0.2, P = 0.03). Although the Ocular Surface Disease Index scores decreased significantly after treatment in both groups, patients in the BCL group had lower Ocular Surface Disease Index scores than those in the AS group (53.4 vs. 41.8 at week 3, 47.1 vs. 31.0 at week 6, 52.7 vs. 32.0 at week 12; P = 0.014, <0.001, <0.004, respectively). The "faces" scores showed improved quality of life in both groups. Tear break-up time improved significantly in both groups except at 6 weeks after discontinuation of the AS. Patients in the BCL group had lower corneal staining scores than those of the AS group after 6 weeks of treatment and 6 weeks after discontinuation of treatment (P < 0.01). There was no significant change in Schirmer I test scores between or within groups. Balafilcon A silicone hydrogel contact lenses as a BCL were effective in the management of SS-associated dry eye. Clinical Trial Registration—URL: http://www.clinicaltrials.gov. Unique identifier: NCT02147509.

  9. Dexamethasone nanowafer as an effective therapy for dry eye disease.

    PubMed

    Coursey, Terry G; Henriksson, Johanna Tukler; Marcano, Daniela C; Shin, Crystal S; Isenhart, Lucas C; Ahmed, Faheem; De Paiva, Cintia S; Pflugfelder, Stephen C; Acharya, Ghanashyam

    2015-09-10

    Dry eye disease is a major public health problem that affects millions of people worldwide. It is presently treated with artificial tear and anti-inflammatory eye drops that are generally administered several times a day and may have limited therapeutic efficacy. To improve convenience and efficacy, a dexamethasone (Dex) loaded nanowafer (Dex-NW) has been developed that can release the drug on the ocular surface for a longer duration of time than drops, during which it slowly dissolves. The Dex-NW was fabricated using carboxymethyl cellulose polymer and contains arrays of 500 nm square drug reservoirs filled with Dex. The in vivo efficacy of the Dex-NW was evaluated using an experimental mouse dry eye model. These studies demonstrated that once a day Dex-NW treatment on alternate days during a five-day treatment period was able to restore a healthy ocular surface and corneal barrier function with comparable efficacy to twice a day topically applied dexamethasone eye drop treatment. The Dex-NW was also very effective in down regulating expression of inflammatory cytokines (TNF-α, and IFN-γ), chemokines (CXCL-10 and CCL-5), and MMP-3, that are stimulated by dry eye. Despite less frequent dosing, the Dex-NW has comparable therapeutic efficacy to topically applied Dex eye drops in experimental mouse dry eye model, and these results provide a strong rationale for translation to human clinical trials for dry eye. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. An evaluation of eye tracking technology in the assessment of 12 lead electrocardiography interpretation.

    PubMed

    Breen, Cathal J; Bond, Raymond; Finlay, Dewar

    2014-01-01

    This study investigated eye tracking technology for 12 lead electrocardiography interpretation to Healthcare Scientist students. Participants (n=33) interpreted ten 12 lead ECG recordings and randomized to receive objective individual appraisal on their efforts either by traditional didactic format or by eye tracker software. One hundred percent of participants reported the experience positively at improving their ECG interpretation competency. ECG analysis time ranged between 13.2 and 59.5s. The rhythm strip was the most common lead studied and fixated on for the longest duration (mean 9.9s). Lead I was studied for the shortest duration (mean 0.25s). Feedback using eye tracking data during ECG interpretation did not produce any significant variation between the assessment marks of the study and the control groups (p=0.32). Although the hypothesis of this study was rejected active teaching and early feedback practices are recommended within this discipline. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Chronic dry eye in photorefractive keratectomy and laser in situ keratomileusis: Manifestations, incidence, and predictive factors.

    PubMed

    Bower, Kraig S; Sia, Rose K; Ryan, Denise S; Mines, Michael J; Dartt, Darlene A

    2015-12-01

    To evaluate dry-eye manifestations after photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK) and determine the incidence and predictive factors of chronic dry eye using a set of dry-eye criteria. Walter Reed Army Medical Center, Washington, DC, USA. Prospective, non-randomized clinical study. Dry-eye evaluation was performed before and after surgery. Main outcome measures included dry-eye manifestations, incidence, and predictive factors of chronic dry eye. This study comprised 143 active-duty U.S. Army personnel, ages 29.9 ± 5.2 years, with myopia or myopic astigmatism (manifest spherical equivalent -3.83 ± 1.96 diopters) having PRK or LASIK. Schirmer scores, corneal sensitivity, ocular surface staining, surface regularity index, and responses to dry-eye questionnaire significantly changed over time after PRK. After LASIK, significant changes were observed in tear breakup time, corneal sensitivity, ocular surface staining, and responses to questionnaire. Twelve months postoperatively, 5.0% of PRK and 0.8% of LASIK participants developed chronic dry eye. Regression analysis showed that pre-operatively lower Schirmer score will significantly influence development of chronic dry eye after PRK, whereas preoperatively, lower Schirmer score or higher ocular surface staining score will significantly influence the occurrence of chronic dry eye after LASIK. Chronic dry eye was uncommon after PRK and LASIK. Ocular surface and tear-film characteristics during pre-operative examination might help to predict chronic dry-eye development in PRK and LASIK. The authors have no financial interest in any product, drug, instrument, or equipment discussed in this manuscript. Copyright © 2015 ASCRS and ESCRS. All rights reserved.

  12. ASSOCIATION BETWEEN VISUAL FUNCTION AND SUBRETINAL DRUSENOID DEPOSITS IN NORMAL AND EARLY AGE-RELATED MACULAR DEGENERATION EYES.

    PubMed

    Neely, David; Zarubina, Anna V; Clark, Mark E; Huisingh, Carrie E; Jackson, Gregory R; Zhang, Yuhua; McGwin, Gerald; Curcio, Christine A; Owsley, Cynthia

    2017-07-01

    To examine the association between subretinal drusenoid deposits (SDDs) identified by multimodal retinal imaging and visual function in older eyes with normal macular health or in the earliest phases of age-related macular degeneration (AMD). Age-related macular degeneration status for each eye was defined according to the Age-Related Eye Disease Study (AREDS) 9-step classification system (normal = Step 1, early AMD = Steps 2-4) based on color fundus photographs. Visual functions measured were best-corrected photopic visual acuity, contrast and light sensitivity, mesopic visual acuity, low-luminance deficit, and rod-mediated dark adaptation. Subretinal drusenoid deposits were identified through multimodal imaging (color fundus photographs, infrared reflectance and fundus autofluorescence images, and spectral domain optical coherence tomography). The sample included 1,202 eyes (958 eyes with normal health and 244 eyes with early AMD). In normal eyes, SDDs were not associated with any visual function evaluated. In eyes with early AMD, dark adaptation was markedly delayed in eyes with SDDs versus no SDD (a 4-minute delay on average), P = 0.0213. However, this association diminished after age adjustment, P = 0.2645. Other visual functions in early AMD eyes were not associated with SDDs. In a study specifically focused on eyes in normal macular health and in the earliest phases of AMD, early AMD eyes with SDDs have slower dark adaptation, largely attributable to the older ages of eyes with SDD; they did not exhibit deficits in other visual functions. Subretinal drusenoid deposits in older eyes in normal macular health are not associated with any visual functions evaluated.

  13. Transcriptome analysis of the planarian eye identifies ovo as a specific regulator of eye regeneration.

    PubMed

    Lapan, Sylvain W; Reddien, Peter W

    2012-08-30

    Among the millions of invertebrate species with visual systems, the genetic basis of eye development and function is well understood only in Drosophila melanogaster. We describe an eye transcriptome for the planarian Schmidtea mediterranea. Planarian photoreceptors expressed orthologs of genes required for phototransduction and microvillus structure in Drosophila and vertebrates, and optic pigment cells expressed solute transporters and melanin synthesis enzymes similar to those active in the vertebrate retinal pigment epithelium. Orthologs of several planarian eye genes, such as bestrophin-1 and Usher syndrome genes, cause eye defects in mammals when perturbed and were not previously described to have roles in invertebrate eyes. Five previously undescribed planarian eye transcription factors were required for normal eye formation during head regeneration. In particular, a conserved, transcription-factor-encoding ovo gene was expressed from the earliest stages of eye regeneration and was required for regeneration of all cell types of the eye. Copyright © 2012 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Transcriptome analysis of the planarian eye identifies ovo as a specific regulator of eye regeneration

    PubMed Central

    Lapan, Sylvain W.; Reddien, Peter W.

    2013-01-01

    Summary Among the millions of invertebrate species with visual systems, the genetic basis of eye development and function is well understood only in Drosophila melanogaster. We describe an eye transcriptome for the planarian Schmidtea mediterranea. Planarian photoreceptors expressed orthologs of genes required for phototransduction and microvillus structure in Drosophila and vertebrates, and optic pigment cells expressed solute transporters and melanin synthesis enzymes similar to those active in the vertebrate retinal pigment epithelium. Orthologs of several planarian eye genes, such as bestrophin-1 and Usher syndrome genes, cause eye defects in mammals when perturbed and were not previously described to have roles in invertebrate eyes. Five previously undescribed planarian eye transcription factors were required for normal eye formation during head regeneration. In particular, a conserved, transcription factor-encoding ovo gene was expressed from the earliest stages of eye regeneration and was required for regeneration of all cell types of the eye. PMID:22884275

  15. A laser-based eye-tracking system.

    PubMed

    Irie, Kenji; Wilson, Bruce A; Jones, Richard D; Bones, Philip J; Anderson, Tim J

    2002-11-01

    This paper reports on the development of a new eye-tracking system for noninvasive recording of eye movements. The eye tracker uses a flying-spot laser to selectively image landmarks on the eye and, subsequently, measure horizontal, vertical, and torsional eye movements. Considerable work was required to overcome the adverse effects of specular reflection of the flying-spot from the surface of the eye onto the sensing elements of the eye tracker. These effects have been largely overcome, and the eye-tracker has been used to document eye movement abnormalities, such as abnormal torsional pulsion of saccades, in the clinical setting.

  16. Rabbits' eye globe sonographic biometry.

    PubMed

    Toni, Maria Carolina; Meirelles, Adriana Érica Wilkes Burton; Gava, Fábio Nelson; Camacho, Aparecido Antônio; Laus, José Luiz; Canola, Júlio Carlos

    2010-11-01

    To measure intraocular structures in New Zealand White breed rabbits (Oryctolagus cuniculus Linnaeus, 1758) using A-mode and B-mode ultrasound with a 20 MHz transducer. In this study, the eyes of 15 rabbits were evaluated for determination of intraocular measurements using an ophthalmic ultrasound unit able to operate in both A and B-modes. The distances from the cornea to the anterior capsule of the lens (D1), from the anterior capsule of the lens to the posterior capsule of the lens (D2), from the posterior capsule of the lens to the retina (D3) and the complete length of the eye, which corresponds to the distance from the cornea to the retina (D4) were taken. The mean values obtained were 2.70 mm (± 0.22 mm) for D1, 7.32 mm (± 0.40 mm) for D2, 7.10 mm (± 0.45 mm) for D3 and 17.12 mm (± 0.41 mm) for D4. Statistical analyses using the Student's t-test showed that there were no differences between the eyes. The study was feasible without the need of pharmacological restraint and yielded normal mean values for ocular sonographic biometry in rabbits. © 2010 American College of Veterinary Ophthalmologists.

  17. Impact of Eye Cosmetics on the Eye, Adnexa, and Ocular Surface.

    PubMed

    Ng, Alison; Evans, Katharine; North, Rachel V; Jones, Lyndon; Purslow, Christine

    2016-07-01

    Despite the fact that cosmetic products undergo rigorous testing to ensure they are safe for human use, some users report mild discomfort following their application. The cutaneous changes, such as allergic dermatitis, are well reported, but the ocular changes associated with eye cosmetic use are less so. Some pigmented cosmetic products may accumulate within the lacrimal system and conjunctivae over many years of use, but immediate reports of eye discomfort after application are most common. Changes to the tear film and its stability may occur shortly after application, and contact lens wearers can also be affected by lens spoliation from cosmetic products. Additionally, creams used in the prevention of skin aging are often applied around the eyes, and retinoids present in these formulations can have negative effects on meibomian gland function and may be a contributing factor to dry eye disease. The aim of this review is to summarize current knowledge regarding the impact of cosmetic products on the eye, ocular surface, and tear film.

  18. Screening for dry eye disease using infrared ocular thermography.

    PubMed

    Tan, Li Li; Sanjay, Srinivasan; Morgan, Philip B

    2016-12-01

    To evaluate the efficacy of infrared (IR) ocular thermography in screening for dry eye disease (DED). IR ocular thermography was performed on 62 dry eye and 63 age- and sex-matched control subjects. Marking of ocular surface and temperature acquisition was done using a novel 'diamond' demarcation method. 30 static- and 30 dynamic-metrics were studied and receiver operating characteristic curves were plotted. Efficacy of the temperature metrics in detecting DED were evaluated singly and in combination in terms of their area under the curve (AUC), Youden's index and discrimination power (DP). Absolute temperature of the extreme nasal conjunctiva 5s and 10s after eye opening were best detectors for DED. With threshold value for the first metric set at 34.7°C, sensitivity and specificity was 87.1% (95% CI: 76.2-94.3%) and 50.8% (95% CI: 37.9-63.6%) respectively. With threshold value for the second metric set at 34.5°C, sensitivity and specificity was 77.6% (95% CI: 64.7-87.5%) and 61.9% (95% CI: 48.8-73.9%) respectively. The two metrics had moderate accuracy and limited performances with AUC of 72% (95% CI: 63-81%) and 73% (95% CI: 64-82%); Youden index of about 0.4 and DP of 1.07 and 1.05 respectively. None of the dynamic metrics was good detector for DED. Combining metrics was not able to increase the AUC. This work suggests some utility for the application of IR ocular thermography for evaluation of dry eye patients. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  19. Trustworthy-Looking Face Meets Brown Eyes

    PubMed Central

    Kleisner, Karel; Priplatova, Lenka; Frost, Peter; Flegr, Jaroslav

    2013-01-01

    We tested whether eye color influences perception of trustworthiness. Facial photographs of 40 female and 40 male students were rated for perceived trustworthiness. Eye color had a significant effect, the brown-eyed faces being perceived as more trustworthy than the blue-eyed ones. Geometric morphometrics, however, revealed significant correlations between eye color and face shape. Thus, face shape likewise had a significant effect on perceived trustworthiness but only for male faces, the effect for female faces not being significant. To determine whether perception of trustworthiness was being influenced primarily by eye color or by face shape, we recolored the eyes on the same male facial photos and repeated the test procedure. Eye color now had no effect on perceived trustworthiness. We concluded that although the brown-eyed faces were perceived as more trustworthy than the blue-eyed ones, it was not brown eye color per se that caused the stronger perception of trustworthiness but rather the facial features associated with brown eyes. PMID:23326406

  20. Posterior Vitreous Detachment With Microplasmin Alters the Retinal Penetration of Intravitreal Bevacizumab (Avastin) in Rabbit Eyes

    PubMed Central

    Goldenberg, David T.; Giblin, Frank J.; Cheng, Mei; Chintala, Shravan K.; Trese, Michael T.; Drenser, Kimberly A.; Ruby, Alan J.

    2010-01-01

    Purpose Intravitreal bevacizumab (Avastin) is frequently used for the treatment of age-related macular degeneration. Previous studies have demonstrated full thickness retinal penetration. Intravitreal recombinant microplasmin (MP) has been shown to successfully induce a posterior vitreous detachment (PVD) and vitreous liquefaction in animals. It has been suggested that a PVD may alter the retinal penetration of molecules in the vitreous cavity. The aim of this study was to compare bevacizumab (BV) retinal penetration in rabbit eyes with and without a MP-induced PVD. Methods Twelve adult rabbits were injected with 0.1 ml (0.4 mg) of MP into the vitreous cavity of one eye. One week later, the rabbits were injected with 0.05 ml (1.25 mg) of BV into both eyes. Both eyes of three rabbits each were harvested at 6, 12, 24, and 72 hours after the BV injection. Frozen retinal cross sections were prepared, and BV retinal penetration was evaluated with immunohistochemistry using a fluorescence-labeled antibody against BV. Two eyes from one rabbit were not injected with either agent and used as controls to compare the background autofluorescence. Peripapillary retinal sections were recorded with a digital camera, and intra-retinal BV fluorescence-labeled antibody was measured by qualitative photographic interpretation. Two additional rabbits received an intravitreal injection of 0.1 ml of MP in one eye. One week later, both eyes from each rabbit were enucleated and frozen retinal sections were prepared and analyzed with light microscopy to evaluate for histologic damage. Results Full thickness BV retinal penetration was observed throughout the retina in both eyes of each rabbit. All of the MP-injected eyes exhibited increased antibody labeling in retinas evaluated 6, 12, and 24 hours after BV injection when compared with the contralateral non-MP-injected eyes. By three days after BV injection, all eyes demonstrated decreased antibody labeling compared to earlier time periods

  1. Promoting organ donation through an entertainment-education TV program in Korea: Open Your Eyes.

    PubMed

    Byoung Kwan Lee; Hyun Soon Park; Choi, Myung-Il; Cheon Soo Kim

    2010-01-01

    The purpose of this study is to investigate the effects of the characteristics of the program, Open Your Eyes, an entertainment-education TV program in Korea, on parasocial interaction and behavioral intention for organ donation. The results indicated that affective evaluation positively affected parasocial interaction with the program but cognitive evaluation negatively affected involvement with beneficiaries in the program. Also, it was found that cognitive evaluation of Open Your Eyes had a significant positive effect on behavioral intention. In addition, a significant positive effect of program engagement on the behavioral intention was found. Thus, the results indicate that individuals who feel program engagement of Open Your Eyes will be more likely to proceed with organ donation. However, no direct effect of involvement with the beneficiary and program hosts was found.

  2. Eye movement perimetry in glaucoma.

    PubMed

    Trope, G E; Eizenman, M; Coyle, E

    1989-08-01

    Present-day computerized perimetry is often inaccurate and unreliable owing to the need to maintain central fixation over long periods while repressing the normal response to presentation of peripheral stimuli. We tested a new method of perimetry that does not require prolonged central fixation. During this test eye movements were encouraged on presentation of a peripheral target. Twenty-three eyes were studied with an Octopus perimeter, with a technician monitoring eye movements. The sensitivity was 100% and the specificity 23%. The low specificity was due to the technician's inability to accurately monitor small eye movements in the central 6 degrees field. If small eye movements are monitored accurately with an eye tracker, eye movement perimetry could become an alternative method to standard perimetry.

  3. Eyes wide shut: implied social presence, eye tracking and attention.

    PubMed

    Risko, Evan F; Kingstone, Alan

    2011-02-01

    People often behave differently when they know they are being watched. Here, we report the first investigation of whether such social presence effects also influence looking behavior--a popular measure of attention allocation. We demonstrate that wearing an eye tracker, an implied social presence, leads individuals to avoid looking at particular stimuli. These results demonstrate that an implied social presence, here an eye tracker, can alter looking behavior. These data provide a new manipulation of social attention, as well as presenting a methodological challenge to researchers using eye tracking.

  4. Statistical evaluation of control inputs and eye movements in the use of instruments clusters during aircraft landing

    NASA Technical Reports Server (NTRS)

    Dick, A. O.; Brown, J. L.; Bailey, G.

    1977-01-01

    Two different types of analyses were done on data from a study in which eye movements and other variables were recorded while four pilots executed landing sequences in a Boeing 737 simulation. Various conditions were manupulated, including changes in turbulence, starting position, and instrumentation. Control inputs were analyzed in the context of the various conditions and compared against ratings of workload obtained using the Cooper-Harper scale. A number of eye-scanning measures including mean dwell time and transition from one instrument to another were entered into a principal components factor analysis. The results show a differentiation between control inputs and eye-scanning behavior. This shows the need for improved definition of workload and experiments to uncover the important differences among control inputs, eye-scanning and cognitive processes of the pilot.

  5. Automatic removal of eye-movement and blink artifacts from EEG signals.

    PubMed

    Gao, Jun Feng; Yang, Yong; Lin, Pan; Wang, Pei; Zheng, Chong Xun

    2010-03-01

    Frequent occurrence of electrooculography (EOG) artifacts leads to serious problems in interpreting and analyzing the electroencephalogram (EEG). In this paper, a robust method is presented to automatically eliminate eye-movement and eye-blink artifacts from EEG signals. Independent Component Analysis (ICA) is used to decompose EEG signals into independent components. Moreover, the features of topographies and power spectral densities of those components are extracted to identify eye-movement artifact components, and a support vector machine (SVM) classifier is adopted because it has higher performance than several other classifiers. The classification results show that feature-extraction methods are unsuitable for identifying eye-blink artifact components, and then a novel peak detection algorithm of independent component (PDAIC) is proposed to identify eye-blink artifact components. Finally, the artifact removal method proposed here is evaluated by the comparisons of EEG data before and after artifact removal. The results indicate that the method proposed could remove EOG artifacts effectively from EEG signals with little distortion of the underlying brain signals.

  6. A 2D eye gaze estimation system with low-resolution webcam images

    NASA Astrophysics Data System (ADS)

    Ince, Ibrahim Furkan; Kim, Jin Woo

    2011-12-01

    In this article, a low-cost system for 2D eye gaze estimation with low-resolution webcam images is presented. Two algorithms are proposed for this purpose, one for the eye-ball detection with stable approximate pupil-center and the other one for the eye movements' direction detection. Eyeball is detected using deformable angular integral search by minimum intensity (DAISMI) algorithm. Deformable template-based 2D gaze estimation (DTBGE) algorithm is employed as a noise filter for deciding the stable movement decisions. While DTBGE employs binary images, DAISMI employs gray-scale images. Right and left eye estimates are evaluated separately. DAISMI finds the stable approximate pupil-center location by calculating the mass-center of eyeball border vertices to be employed for initial deformable template alignment. DTBGE starts running with initial alignment and updates the template alignment with resulting eye movements and eyeball size frame by frame. The horizontal and vertical deviation of eye movements through eyeball size is considered as if it is directly proportional with the deviation of cursor movements in a certain screen size and resolution. The core advantage of the system is that it does not employ the real pupil-center as a reference point for gaze estimation which is more reliable against corneal reflection. Visual angle accuracy is used for the evaluation and benchmarking of the system. Effectiveness of the proposed system is presented and experimental results are shown.

  7. Mapping owl's eye cells of patients with cytomegalovirus corneal endotheliitis using in vivo laser confocal microscopy.

    PubMed

    Yokogawa, Hideaki; Kobayashi, Akira; Sugiyama, Kazuhisa

    2013-01-01

    To produce a two-dimensional reconstruction map of owl's eye cells using in vivo laser confocal microscopy in patients with cytomegalovirus (CMV) corneal endotheliitis, and to demonstrate any association between owl's eye cells and coin-shaped lesions observed with slit-lamp biomicroscopy. Two patients (75- and 77-year-old men) with polymerase chain reaction-proven CMV corneal endotheliitis were evaluated in this study. Slit-lamp biomicroscopy and in vivo laser confocal microscopy were performed. Images of owl's eye cells in the endothelial cell layer were arranged and mapped into subconfluent montages. Montage images of owl's eye cells were then superimposed on a slit-lamp photo of the corresponding coin-shaped lesion. Degree of concordance between the confocal microscopic images and slit-lamp photos was evaluated. In both eyes, a two-dimensional reconstruction map of the owl's eye cells was created by computer software using acquired confocal images; the maps showed circular patterns. Superimposing montage images of owl's eye cells onto the photos of a coin-shaped lesion showed good concordance in the two eyes. This study suggests that there is an association between owl's eye cells observed by confocal microscopy and coin-shaped lesions observed by slit-lamp biomicroscopy in patients with CMV corneal endotheliitis. The use of in vivo laser confocal microscopy may provide clues as to the underlying causes of CMV corneal endotheliitis.

  8. Immediate sequential bilateral cataract surgery: A 5-year retrospective analysis of 2470 eyes from a tertiary care eye center in South India

    PubMed Central

    Ganesh, Sri; Brar, Sheetal; Sreenath, Rohit

    2017-01-01

    Purpose: The purpose of this study is to evaluate the safety and benefits of immediate sequential bilateral cataract surgery. Patients and Methods: Retrospective data analysis of patients who underwent immediate sequential bilateral phacoemulsification with foldable intraocular lens (IOL) implantation under topical anesthesia from January 2011 to September 2016 was performed. Patients with visually significant bilateral cataract within the axial length range of 21.0–26.5 mm were included in the study. Intraoperative and postoperative complications were evaluated. Results: Two thousand four hundred and seventy eyes from 1235 patients with a mean age of 68.34 years (range: 4–90 years) were analyzed. Best-corrected visual acuity improved from 0.40 ± 0.17 to 0.08 ± 0.10 (logarithm of the minimum angle of resolution). Nearly 92.05% eyes achieved a target postoperative refraction of ± 0.5 D spherical equivalent. Main complications observed were prolonged postoperative inflammation in 25% (n = 31), posterior capsular tears in 0.45% (n = 11), and unilateral cystoid macular edema in 0.08% (n = 2) eyes. No sight-threatening complications such as endophthalmitis, retinal detachment, corneal decompensation and intraocular hemorrhage occurred in any of the eyes. Out of the 288 (23.2%) patients who underwent bilateral multifocal IOL implantation, 23 patients (46 eyes) had femtolaser-assisted cataract surgery procedure. Two pediatric and one Downs syndrome patient underwent bilateral cataract surgery under general anesthesia and intravenous sedation, respectively. Conclusion: IBSCS may be considered as a preferred practice in eligible cases considering significant patient benefits such as early visual rehabilitation, time and cost-effectiveness, and better compliance with postoperative medications. In debilitated patients and special situations, such as pediatric cataract and Downs syndrome requiring general anesthesia it may be the ideal procedure. PMID:28573990

  9. Penetrating eye injury in war.

    PubMed

    Biehl, J W; Valdez, J; Hemady, R K; Steidl, S M; Bourke, D L

    1999-11-01

    The percentage of penetrating eye injuries in war has increased significantly in this century compared with the total number of combat injuries. With the increasing use of fragmentation weapons and possibly laser weapons on the battle-field in the future, the rate of eye injuries may exceed the 13% of the total military injuries found in Operations Desert Storm/Shield. During the Iran-Iraq War (1980-1988), eye injuries revealed that retained foreign bodies and posterior segment injuries have an improved prognosis in future military ophthalmic surgery as a result of modern diagnostic and treatment modalities. Compared with the increasing penetrating eye injuries on the battlefield, advances in ophthalmic surgery are insignificant. Eye armor, such as visors that flip up and down and protect the eyes from laser injury, needs to be developed. Similar eye protection is being developed in civilian sportswear. Penetrating eye injury in the civilian sector is becoming much closer to the military model and is now comparable for several reasons.

  10. A method to reduce patient's eye lens dose in neuro-interventional radiology procedures

    NASA Astrophysics Data System (ADS)

    Safari, M. J.; Wong, J. H. D.; Kadir, K. A. A.; Sani, F. M.; Ng, K. H.

    2016-08-01

    Complex and prolonged neuro-interventional radiology procedures using the biplane angiography system increase the patient's risk of radiation-induced cataract. Physical collimation is the most effective way of reducing the radiation dose to the patient's eye lens, but in instances where collimation is not possible, an attenuator may be useful in protecting the eyes. In this study, an eye lens protector was designed and fabricated to reduce the radiation dose to the patients' eye lens during neuro-interventional procedures. The eye protector was characterised before being tested on its effectiveness in a simulated aneurysm procedure on an anthropomorphic phantom. Effects on the automatic dose rate control (ADRC) and image quality are also evaluated. The eye protector reduced the radiation dose by up to 62.1% at the eye lens. The eye protector is faintly visible in the fluoroscopy images and increased the tube current by a maximum of 3.7%. It is completely invisible in the acquisition mode and does not interfere with the clinical procedure. The eye protector placed within the radiation field of view was able to reduce the radiation dose to the eye lens by direct radiation beam of the lateral x-ray tube with minimal effect on the ADRC system.

  11. Neuropathic ocular pain: an important yet underevaluated feature of dry eye

    PubMed Central

    Galor, A; Levitt, R C; Felix, E R; Martin, E R; Sarantopoulos, C D

    2015-01-01

    Dry eye has gained recognition as a public health problem given its prevalence, morbidity, and cost implications. Dry eye can have a variety of symptoms including blurred vision, irritation, and ocular pain. Within dry eye-associated ocular pain, some patients report transient pain whereas others complain of chronic pain. In this review, we will summarize the evidence that chronicity is more likely to occur in patients with dysfunction in their ocular sensory apparatus (ie, neuropathic ocular pain). Clinical evidence of dysfunction includes the presence of spontaneous dysesthesias, allodynia, hyperalgesia, and corneal nerve morphologic and functional abnormalities. Both peripheral and central sensitizations likely play a role in generating the noted clinical characteristics. We will further discuss how evaluating for neuropathic ocular pain may affect the treatment of dry eye-associated chronic pain. PMID:25376119

  12. Shadow image on the retina of a defocused eye

    NASA Astrophysics Data System (ADS)

    Lenskii, A. V.

    1994-04-01

    Some visual conditions for transparent objects positioned within and beyond the accommodation limits on the path of the light traveling from a remote source of a small angular size are theoretically considered for the naked eye with a strong ametropia. The resolving power and admissible angular size of the light source are evaluated. The predicted possibility of seeing sufficiently extended transparent gratings at such distances has found that the density of ruling of the grating-object is higher than the ultimate angular resolution of the normal eye.

  13. Effect of chitosan-N-acetylcysteine conjugate in a mouse model of botulinum toxin B-induced dry eye.

    PubMed

    Hongyok, Teeravee; Chae, Jemin J; Shin, Young Joo; Na, Daero; Li, Li; Chuck, Roy S

    2009-04-01

    To evaluate the effect of a thiolated polymer lubricant, chitosan-N-acetylcysteine conjugate (C-NAC), in a mouse model of dry eye. Eye drops containing 0.5% C-NAC, 0.3% C-NAC, a vehicle (control group), artificial tears, or fluorometholone were applied in a masked fashion in a mouse model of induced dry eye from 3 days to 4 weeks after botulinum toxin B injection. Corneal fluorescein staining was periodically recorded. Real-time reverse transcriptase-polymerase chain reaction and immunofluorescence staining were performed at the end of the study to evaluate inflammatory cytokine expressions. Mice treated with C-NAC, 0.5%, and fluorometholone showed a downward trend that was not statistically significant in corneal staining compared with the other groups. Chitosan-NAC formulations, fluorometholone, and artificial tears significantly decreased IL-1beta (interleukin 1beta), IL-10, IL-12alpha, and tumor necrosis factor alpha expression in ocular surface tissues. The botulinum toxin B-induced dry eye mouse model is potentially useful in evaluating new dry eye treatment. Evaluation of important molecular biomarkers suggests that C-NAC may impart some protective ocular surface properties. However, clinical data did not indicate statistically significant improvement of tear production and corneal staining in any of the groups tested. Topically applied C-NAC might protect the ocular surface in dry eye syndrome, as evidenced by decreased inflammatory cytokine expression.

  14. Impact of First Eye versus Second Eye Cataract Surgery on Visual Function and Quality of Life.

    PubMed

    Shekhawat, Nakul S; Stock, Michael V; Baze, Elizabeth F; Daly, Mary K; Vollman, David E; Lawrence, Mary G; Chomsky, Amy S

    2017-10-01

    To compare the impact of first eye versus second eye cataract surgery on visual function and quality of life. Cohort study. A total of 328 patients undergoing separate first eye and second eye phacoemulsification cataract surgeries at 5 veterans affairs centers in the United States. Patients with previous ocular surgery, postoperative endophthalmitis, postoperative retinal detachment, reoperation within 30 days, dementia, anxiety disorder, hearing difficulty, or history of drug abuse were excluded. Patients received complete preoperative and postoperative ophthalmic examinations for first eye and second eye cataract surgeries. Best-corrected visual acuity (BCVA) was measured 30 to 90 days preoperatively and postoperatively. Patients completed the National Eye Institute Visual Functioning Questionnaire (NEI-VFQ) 30 to 90 days preoperatively and postoperatively. The NEI-VFQ scores were calculated using a traditional subscale scoring algorithm and a Rasch-refined approach producing visual function and socioemotional subscale scores. Postoperative NEI-VFQ scores and improvement in NEI-VFQ scores comparing first eye versus second eye cataract surgery. Mean age was 70.4 years (±9.6 standard deviation [SD]). Compared with second eyes, first eyes had worse mean preoperative BCVA (0.55 vs. 0.36 logarithm of the minimum angle of resolution (logMAR), P < 0.001), greater mean BCVA improvement after surgery (-0.50 vs. -0.32 logMAR, P < 0.001), and slightly worse postoperative BCVA (0.06 vs. 0.03 logMAR, P = 0.039). Compared with first eye surgery, second eye surgery resulted in higher postoperative NEI-VFQ scores for nearly all traditional subscales (P < 0.001), visual function subscale (-3.85 vs. -2.91 logits, P < 0.001), and socioemotional subscale (-2.63 vs. -2.10 logits, P < 0.001). First eye surgery improved visual function scores more than second eye surgery (-2.99 vs. -2.67 logits, P = 0.021), but both first and second eye surgeries resulted in similar

  15. Cyclosporine Amicellar delivery system for dry eyes.

    PubMed

    Kang, Han; Cha, Kwang-Ho; Cho, Wonkyung; Park, Junsung; Park, Hee Jun; Sun, Bo Kyung; Hyun, Sang-Min; Hwang, Sung-Joo

    2016-01-01

    The objectives of this study were to develop stable cyclosporine A (CsA) ophthalmic micelle solutions for dry-eye syndrome and evaluate their physicochemical properties and therapeutic efficacy. CsA-micelle solutions (MS-CsA) were created by a simple method with Cremophor EL, ethanol, and phosphate buffer. We investigated the particle size, pH, and osmolarity. In addition, long-term physical and chemical stability for MS-CsA was observed. To confirm the therapeutic efficacy, tear production in dry eye-induced rabbits was evaluated using the Schirmer tear test (STT). When compared to a commercial product, Restasis, MS-CsA demonstrated improvement in goblet-cell density and conjunctival epithelial morphology, as demonstrated in histological hematoxylin and eosin staining. MS-CsA had a smaller particle size (average diameter 14-18 nm) and a narrow size distribution. Physicochemical parameters, such as particle size, pH, osmolarity, and remaining CsA concentration were all within the expected range of 60 days. STT scores significantly improved in MS-CsA treated groups (P<0.05) in comparison to those of the Restasis-treated group. The number of goblet cells for rabbit conjunctivas after the administration of MS-CsA was 94.83±8.38, a significantly higher result than the 65.17±11.51 seen with Restasis. The conjunctival epithelial morphology of dry eye-induced rabbits thinned with loss of goblet cells. However, after 5 days of treatment with drug formulations, rabbit conjunctivas recovered epithelia and showed a relative increase in the number of goblet cells. The results of this study indicate the potential use of a novel MS for the ophthalmic delivery of CsA in treating dry eyes.

  16. Cyclosporine Amicellar delivery system for dry eyes

    PubMed Central

    Kang, Han; Cha, Kwang-Ho; Cho, Wonkyung; Park, Junsung; Park, Hee Jun; Sun, Bo Kyung; Hyun, Sang-Min; Hwang, Sung-Joo

    2016-01-01

    Background The objectives of this study were to develop stable cyclosporine A (CsA) ophthalmic micelle solutions for dry-eye syndrome and evaluate their physicochemical properties and therapeutic efficacy. Materials and methods CsA-micelle solutions (MS-CsA) were created by a simple method with Cremophor EL, ethanol, and phosphate buffer. We investigated the particle size, pH, and osmolarity. In addition, long-term physical and chemical stability for MS-CsA was observed. To confirm the therapeutic efficacy, tear production in dry eye-induced rabbits was evaluated using the Schirmer tear test (STT). When compared to a commercial product, Restasis, MS-CsA demonstrated improvement in goblet-cell density and conjunctival epithelial morphology, as demonstrated in histological hematoxylin and eosin staining. Results MS-CsA had a smaller particle size (average diameter 14–18 nm) and a narrow size distribution. Physicochemical parameters, such as particle size, pH, osmolarity, and remaining CsA concentration were all within the expected range of 60 days. STT scores significantly improved in MS-CsA treated groups (P<0.05) in comparison to those of the Restasis-treated group. The number of goblet cells for rabbit conjunctivas after the administration of MS-CsA was 94.83±8.38, a significantly higher result than the 65.17±11.51 seen with Restasis. The conjunctival epithelial morphology of dry eye-induced rabbits thinned with loss of goblet cells. However, after 5 days of treatment with drug formulations, rabbit conjunctivas recovered epithelia and showed a relative increase in the number of goblet cells. Conclusion The results of this study indicate the potential use of a novel MS for the ophthalmic delivery of CsA in treating dry eyes. PMID:27382280

  17. Insights into numerical cognition: considering eye-fixations in number processing and arithmetic.

    PubMed

    Mock, J; Huber, S; Klein, E; Moeller, K

    2016-05-01

    Considering eye-fixation behavior is standard in reading research to investigate underlying cognitive processes. However, in numerical cognition research eye-tracking is used less often and less systematically. Nevertheless, we identified over 40 studies on this topic from the last 40 years with an increase of eye-tracking studies on numerical cognition during the last decade. Here, we review and discuss these empirical studies to evaluate the added value of eye-tracking for the investigation of number processing. Our literature review revealed that the way eye-fixation behavior is considered in numerical cognition research ranges from investigating basic perceptual aspects of processing non-symbolic and symbolic numbers, over assessing the common representational space of numbers and space, to evaluating the influence of characteristics of the base-10 place-value structure of Arabic numbers and executive control on number processing. Apart from basic results such as reading times of numbers increasing with their magnitude, studies revealed that number processing can influence domain-general processes such as attention shifting-but also the other way round. Domain-general processes such as cognitive control were found to affect number processing. In summary, eye-fixation behavior allows for new insights into both domain-specific and domain-general processes involved in number processing. Based thereon, a processing model of the temporal dynamics of numerical cognition is postulated, which distinguishes an early stage of stimulus-driven bottom-up processing from later more top-down controlled stages. Furthermore, perspectives for eye-tracking research in numerical cognition are discussed to emphasize the potential of this methodology for advancing our understanding of numerical cognition.

  18. Toward building an anatomically correct solid eye model with volumetric representation of retinal morphology

    NASA Astrophysics Data System (ADS)

    Zawadzki, Robert J.; Rowe, T. Scott; Fuller, Alfred R.; Hamann, Bernd; Werner, John S.

    2010-02-01

    An accurate solid eye model (with volumetric retinal morphology) has many applications in the field of ophthalmology, including evaluation of ophthalmic instruments and optometry/ophthalmology training. We present a method that uses volumetric OCT retinal data sets to produce an anatomically correct representation of three-dimensional (3D) retinal layers. This information is exported to a laser scan system to re-create it within solid eye retinal morphology of the eye used in OCT testing. The solid optical model eye is constructed from PMMA acrylic, with equivalent optical power to that of the human eye (~58D). Additionally we tested a water bath eye model from Eyetech Ltd. with a customized retina consisting of five layers of ~60 μm thick biaxial polypropylene film and hot melt rubber adhesive.

  19. Comparing Eye Tracking with Electrooculography for Measuring Individual Sentence Comprehension Duration

    PubMed Central

    Müller, Jana Annina; Wendt, Dorothea; Kollmeier, Birger; Brand, Thomas

    2016-01-01

    The aim of this study was to validate a procedure for performing the audio-visual paradigm introduced by Wendt et al. (2015) with reduced practical challenges. The original paradigm records eye fixations using an eye tracker and calculates the duration of sentence comprehension based on a bootstrap procedure. In order to reduce practical challenges, we first reduced the measurement time by evaluating a smaller measurement set with fewer trials. The results of 16 listeners showed effects comparable to those obtained when testing the original full measurement set on a different collective of listeners. Secondly, we introduced electrooculography as an alternative technique for recording eye movements. The correlation between the results of the two recording techniques (eye tracker and electrooculography) was r = 0.97, indicating that both methods are suitable for estimating the processing duration of individual participants. Similar changes in processing duration arising from sentence complexity were found using the eye tracker and the electrooculography procedure. Thirdly, the time course of eye fixations was estimated with an alternative procedure, growth curve analysis, which is more commonly used in recent studies analyzing eye tracking data. The results of the growth curve analysis were compared with the results of the bootstrap procedure. Both analysis methods show similar processing durations. PMID:27764125

  20. Effect of Viscous Agents on Corneal Density in Dry Eye Disease.

    PubMed

    Wegener, Alfred R; Meyer, Linda M; Schönfeld, Carl-Ludwig

    2015-10-01

    To investigate the effect of the viscous agents, hydroxypropyl methylcellulose (HPMC), carbomer, povidone, and a combination of HPMC and povidone on corneal density in patients with dry eye disease. In total, 98 eyes of 49 patients suffering from dry eye and 65 eyes of 33 healthy age-matched individuals were included in this prospective, randomized study. Corneal morphology was documented with Scheimpflug photography and corneal density was analyzed in 5 anatomical layers (epithelium, bowman membrane, stroma, descemet's membrane, and endothelium). Corneal density was evaluated for the active ingredients HPMC, carbomer, povidone, and a combination of HPMC and povidone as the viscous agents contained in the artificial tear formulations used by the dry eye patients. Data were compared to the age-matched healthy control group without medication. Corneal density in dry eye patients was reduced in all 5 anatomical layers compared to controls. Corneal density was highest and very close to control in patients treated with HPMC containing ocular lubricants. Patients treated with lubricants, including carbomer as the viscous agent displayed a significant reduction of corneal density in layers 1 and 2 compared to control. HPMC containing ocular lubricants can help to maintain physiological corneal density and may be beneficial in the treatment of dry eye disease.

  1. The Minnesota Grading System using fundus autofluorescence of eye bank eyes: a correlation to age-related macular degeneration (an AOS thesis).

    PubMed

    Olsen, Timothy W

    2008-01-01

    To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores.

  2. Eye Safety. Mississippi Industrial Arts.

    ERIC Educational Resources Information Center

    Mississippi State Dept. of Education, Jackson. Div. of Vocational and Technical Education.

    This manual is designed to help industrial arts teachers eliminate student eye injuries within industrial arts programs. Presented first is Mississippi eye safety law. Following a discussion of eye protection equipment, illustrations of eye protection devices are provided. Guidelines are set forth for selecting shade numbers for welding filters.…

  3. Knowledge, Attitude, and Practice of Dry Eye Treatment by Institutional Chinese Physicians in Singapore

    PubMed Central

    Lan, Wanwen; Lee, Sze Yee; Lee, Man Xin; Tong, Louis

    2012-01-01

    Dry eye is a common health problem worldwide, causing significant discomfort and inconvenience to sufferers. The conventional treatment of dry eye via topical administration of eye drops is deemed palliative and unsatisfactory to many. Traditional Chinese medicine (TCM) has shown some promise in dry eye treatment; however, the extent of its use and acceptance is uncertain. We evaluated the knowledge, attitude, and practice of institutional TCM practitioners in the treatment of dry eye in Singapore. A questionnaire was generated to address the study aims and sent to TCM practitioners listed in the Singapore TCM practitioners' board database. About three quarters of respondents thought that dry eye was not severe enough to be a public health burden but most thought that TCM was effective in the treatment of dry eye. Acupuncture and herbal medicine were most commonly used TCM modalities in dry eye treatment, and a single TCM treatment session would be charged S$20–50 by the practitioner. The majority of surveyed institutional TCM practitioners in Singapore believe that TCM is relevant in dry eye treatment. Public awareness should be raised regarding the availability of TCM as alternative medicine for dry eye. PMID:23213306

  4. Comparison of 16 mm OSU‐Nag and COMS eye plaques

    PubMed Central

    Davidorf, Frederick; Qi, Yujin

    2012-01-01

    OSU‐NAG eye plaques use fewer sources than COMS‐plaques of comparable size, and do not employ a Silastic seed carrier insert. Monte Carlo modeling was used to calculate 3D dose distributions for a 16 mm OSU‐NAG eye plaque and a 16 mm COMS eye plaque loaded with either Iodine‐125 or Cesium‐131 brachytherapy sources. The OSU‐NAG eye plaque was loaded with eight sources forming two squares, whereas the COMS eye plaque was loaded with thirteen sources approximating three isocentric circles. A spherical eyeball 24.6 mm in diameter and an ellipsoid‐like tumor 6 mm in height and 12 mm in the major and minor axes were used to evaluate the doses delivered. To establish a fair comparison, a water seed carrier was used instead of the Silastic seed carrier designed for the traditional COMS eye plaque. Calculations were performed on the dose distributions along the eye plaque axis and the DVHs of the tumor, as well as the 3D distribution. Our results indicated that, to achieve a prescription dose of 85 Gy at 6 mm from the inner sclera edge for a six‐day treatment, the OSU‐NAG eye plaque will need 6.16 U/source and 6.82 U/source for  125I and  131Cs, respectively. The COMS eye plaque will require 4.02 U/source and 4.43 U/source for the same source types. The dose profiles of the two types of eye plaques on their central axes are within 9% difference for all applicable distances. The OSU‐NAG plaque delivers about 10% and 12% more dose than the COMS for  125I and  131Cs sources, respectively, at the inner sclera edge, but 6% and 3% less dose at the opposite retina. The DVHs of the tumor for two types of plaques were within 6% difference. In conclusion, the dosimetric quality of the OSU‐NAG eye plaque used in eye plaque brachytherapy is comparable to the COMS eye plaque. PACS number: 87.56B, 87.55k, 87.55kh PMID:22584165

  5. Post-LASIK dry eye

    PubMed Central

    Shtein, Roni M

    2011-01-01

    Laser-assisted in situ keratomileusis (LASIK) is a frequently performed corneal refractive surgery with excellent refractive outcomes. The most common complication of LASIK is dry eyes, with virtually all patients developing some degree of dryness in the immediate postoperative period. Identifying preoperative dry eyes, and conscientious attention and treatment in the perioperative time period, can lead to enhanced patient satisfaction and more accurate visual outcomes. Improved understanding of the development of dry eyes after LASIK will advance our understanding of the complex pathophysiology of dry eye disease. PMID:22174730

  6. [Analysis of risk factors for dry eye syndrome in visual display terminal workers].

    PubMed

    Zhu, Yong; Yu, Wen-lan; Xu, Ming; Han, Lei; Cao, Wen-dong; Zhang, Hong-bing; Zhang, Heng-dong

    2013-08-01

    To analyze the risk factors for dry eye syndrome in visual display terminal (VDT) workers and to provide a scientific basis for protecting the eye health of VDT workers. Questionnaire survey, Schirmer I test, tear break-up time test, and workshop microenvironment evaluation were performed in 185 VDT workers. Multivariate logistic regression analysis was performed to determine the risk factors for dry eye syndrome in VDT workers after adjustment for confounding factors. In the logistic regression model, the regression coefficients of daily mean time of exposure to screen, daily mean time of watching TV, parallel screen-eye angle, upward screen-eye angle, eye-screen distance of less than 20 cm, irregular breaks during screen-exposed work, age, and female gender on the results of Schirmer I test were 0.153, 0.548, 0.400, 0.796, 0.234, 0.516, 0.559, and -0.685, respectively; the regression coefficients of daily mean time of exposure to screen, parallel screen-eye angle, upward screen-eye angle, age, working years, and female gender on tear break-up time were 0.021, 0.625, 2.652, 0.749, 0.403, and 1.481, respectively. Daily mean time of exposure to screen, daily mean time of watching TV, parallel screen-eye angle, upward screen-eye angle, eye-screen distance of less than 20 cm, irregular breaks during screen-exposed work, age, and working years are risk factors for dry eye syndrome in VDT workers.

  7. Topical cyclosporine a treatment in corneal refractive surgery and patients with dry eye.

    PubMed

    Torricelli, Andre A M; Santhiago, Marcony R; Wilson, Steven E

    2014-08-01

    To evaluate preoperative and postoperative dry eye and the effect of cyclosporine A treatment in patients screened for corneal refractive surgery and treated with photorefractive keratectomy (PRK) or LASIK. A consecutive case series of 1,056 patients screened for corneal refractive surgery from 2007 to 2012 was retrospectively analyzed. The level of preoperative and postoperative dry eye and the responsiveness to topical cyclosporine A treatment were assessed. One eye of each patient was randomly selected. A total of 642 eyes progressed to surgery: 524 (81.6%) and 118 (18.4%) underwent LASIK and PRK, respectively. Of 81 (7.7%) diagnosed as having dry eye, 55 were deemed potential candidates and optimized for refractive surgery. Thirty-seven patients with moderate dry eye were treated with topical cyclosporine A prior to surgery (mean duration: 3.2 ± 2.1 months; range: 1 to 12 months). After cyclosporine A treatment, 28 (75.7%) eyes underwent LASIK, 4 (10.8%) eyes underwent PRK, and 5 (13.5%) eyes were not operated on due to failed treatment of dry eye. Postoperative refractive surgery-induced neurotrophic epitheliopathy (LINE in LASIK) was noted in 132 (27.3%) and 12 (11.1%) eyes that underwent LASIK and PRK, respectively. Topical cyclosporine A was prescribed in 79 LASIK-induced and 3 PRK-induced dry eyes. After 12 months or more of cyclosporine A treatment, 5 (6.1%) eyes continued to have dry eye symptoms or signs. Topical cyclosporine A treatment is effective therapy for optimizing patients for refractive surgery and treatment of new onset or worsened dry eye after surgery. Copyright 2014, SLACK Incorporated.

  8. Influence of eye rotation on peripheral eye length measurement obtained with a partial coherence interferometry instrument.

    PubMed

    Verkicharla, Pavan K; Suheimat, Marwan; Mallen, Edward A H; Atchison, David A

    2014-01-01

    The eye rotation approach for measuring peripheral eye length leads to concern about whether the rotation influences results, such as through pressure exerted by eyelids or extra-ocular muscles. This study investigated whether this approach is valid. Peripheral eye lengths were measured with a Lenstar LS 900 biometer for eye rotation and no-eye rotation conditions (head rotation for horizontal meridian and instrument rotation for vertical meridian). Measurements were made for 23 healthy young adults along the horizontal visual field (± 30°) and, for a subset of eight participants along the vertical visual field (± 25°). To investigate the influence of the duration of eye rotation, for six participants measurements were made at 0, 60, 120, 180 and 210 s after eye rotation to ± 30° along horizontal and vertical visual fields. Peripheral eye lengths were not significantly different for the conditions along the vertical meridian (F1,7 = 0.16, p = 0.71). The peripheral eye lengths for the conditions were significantly different along the horizontal meridian (F1,22 = 4.85, p = 0.04), although not at individual positions (p ≥ 0.10) and were not important. There were no apparent differences between the emmetropic and myopic groups. There was no significant change in eye length at any position after maintaining position for 210 s. Eye rotation and no-eye rotation conditions were similar for measuring peripheral eye lengths along horizontal and vertical visual field meridians at ± 30° and ± 25°, respectively. Either condition can be used to estimate retinal shape from peripheral eye lengths. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  9. Validity of Eye Movement Methods and Indices for Capturing Semantic (Associative) Priming Effects

    ERIC Educational Resources Information Center

    Odekar, Anshula; Hallowell, Brooke; Kruse, Hans; Moates, Danny; Lee, Chao-Yang

    2009-01-01

    Purpose: The purpose of this investigation was to evaluate the usefulness of eye movement methods and indices as a tool for studying priming effects by verifying whether eye movement indices capture semantic (associative) priming effects in a visual cross-format (written word to semantically related picture) priming paradigm. Method: In the…

  10. German register for glaucoma patients with dry eye. I. Basic outcome with respect to dry eye.

    PubMed

    Erb, Carl; Gast, Ulrike; Schremmer, Dieter

    2008-11-01

    The purpose of this register was to determine the links between glaucoma, age, concomitant disease, medication, and dry eye in a large group of glaucoma patients. A total of 20,506 patients from 900 centers across Germany were included. The first 30 consecutive glaucoma patients at each center were recruited. Epidemiological data as well as information on glaucoma, medication, concomitant diseases, dry eye, and local symptoms were elicited by means of a questionnaire. We analyzed primary open-angle glaucoma (POAG), pseudoexfoliation glaucoma (PEX), and pigmentary glaucoma (PDG). According to the register data, more women develop dry eye and glaucoma than men (56.9 vs. 45.7%). The most frequent concomitant systemic diseases were hypertension (48.1%), diabetes mellitus (22.5%), and dry mouth, nose, and skin (11.3%). As expected, the highest incidence of dry eye was found in those patients with dry mouth, nose, and skin. Dry eye occurred with dissimilar frequencies in association with the various glaucoma types: PEX>POAG>PDG. The incidence of dry eye increases with age. The gender difference in the occurrence of dry eye becomes apparent from the age of 50. Dry eye occurred more frequently when three or more antiglaucoma drugs were used and increased with the duration of glaucoma disease. We publish the first results from the German Glaucoma and Dry Eye Register. We found that the occurrence of dry eye is linked to several factors. Thus, the type of glaucoma has an impact on the risk of dry eye. The quantity of eye drops applied also plays a role in the development of the dry eye syndrome if more than three medications are used. While POAG is usually treated with one drug, PEX and PDG tend to be treated with multiple drugs. The gender difference in the occurrence of dry eye becomes apparent from the age 50 years. Because of the vicious circle of dry eye, antiglaucoma eye drops containing benzalkonium chloride compromises patient compliance. The results of the register

  11. Eye muscle repair

    MedlinePlus

    ... and physical exam before the procedure Orthoptic measurements (eye movement measurements) Always tell your child's health care provider: ... D, Plummer LS, Stass-Isern M. Disorders of eye movement and alignment. In: Kliegman RM, Stanton BF, St. ...

  12. Eye Protection in Educational Institutions.

    ERIC Educational Resources Information Center

    New Jersey State Dept. of Education, Trenton. Div. of Vocational Education.

    Intended to help reduce the number of school eye injuries in New Jersey, this document begins with a brief review of existing legislation regarding eye protection in educational institutions and a list of elements essential in an eye safety program. Second, eye protection equipment is examined in terms of: the advantages of safety spectacles over…

  13. Efficacy of topical nerve growth factor treatment in dogs affected by dry eye.

    PubMed

    Coassin, Marco; Lambiase, Alessandro; Costa, Nicola; De Gregorio, Alessandra; Sgrulletta, Roberto; Sacchetti, Marta; Aloe, Luigi; Bonini, Stefano

    2005-02-01

    Preliminary data show that nerve growth factor (NGF) may improve tear production in humans. We evaluated the efficacy of topical NGF treatment in dogs who developed dry eye after the excision of the third eyelid lacrimal gland. English Bulldogs (2- to 6-year-old males and females) that had undergone the surgical removal of the prolapsed lacrimal gland of the third eyelid in both eyes at the age of 3-6 months developed chronic keratoconjunctivitis sicca associated with a decrease of Schirmer tear test I values after at least 1 year. One eye, randomly selected, of each dog was treated twice daily with 100 microl of NGF ointment for 1 month, while the fellow eye was used as control and treated with the ointment vehicle only. At baseline and after 1 month of NGF treatment the following examinations were performed: corneal evaluation by slit lamp, fluorescein staining, Schirmer tear test I, tear ferning test, corneal esthesiometry by cotton swab and conjunctival impression cytology. Topical application of NGF caused a significant improvement of all the evaluated parameters compared with baseline values. In contrast, in the control eyes there was no significant difference between the values measured before and after treatment. In particular, after NGF treatment superficial punctate keratopathy was resolved, corneal haze was reduced from stage 4 to stage 2 and Schirmer test values increased (17.2+/-1.7 mm/min vs 4.5+/-1.3 mm/min; p<0.05), as did the tear mucous component (as demonstrated by ferning test: 2.0+/-0.0 vs 4.0+/-0.0; p<0.05); conjunctival impression cytology evaluation demonstrated the presence of numerous mucous filaments and a significant increase in conjunctival goblet cell density (102.7+/-68.3 vs. 18.2+/-14.3 cell x field; p<0.05). Topical NGF treatment improved corneal sensitivity in two of three eyes. This open study suggests that topical application of NGF may enhance the production and functional characteristics in tear film, with an improvement of

  14. An Evaluation of the "Reading the Mind in the Eyes-Test" with Seventh to Ninth Graders

    ERIC Educational Resources Information Center

    Müller, Christoph Michael; Gmünder, Lena

    2014-01-01

    Individuals with autism spectrum disorders are often considered to have difficulty with using facial cues (e.g., cues from the eye region) to understand others' mental states. One of the pioneering assessments to test competence in this skill is the "Reading the Mind in the Eyes-Test" (RMET). In order to find out more about the…

  15. New Eye-Tracking Techniques May Revolutionize Mental Health Screening

    DTIC Science & Technology

    2015-11-04

    health? Recent progress in eye-tracking tech- niques is opening new avenues for quanti - tative, objective, simple, inexpensive, and rapid evaluation ...to check with your doctor whether any corrective action should be taken. What if similar devices could be made available for the evaluation of mental... evaluations , especially for those disor- ders for which a clear chemical, genetic, morphological, physiological, or histologi- cal biomarker has not yet

  16. Effectiveness of an Eyelid Thermal Pulsation Procedure to Treat Recalcitrant Dry Eye Symptoms After Laser Vision Correction.

    PubMed

    Schallhorn, Craig S; Schallhorn, Julie M; Hannan, Stephen; Schallhorn, Steven C

    2017-01-01

    To provide an initial retrospective evaluation of the effectiveness of a thermal pulsation system to treat intractable patient-reported dye eye symptoms following laser vision correction. A total of 109 eyes of 57 patients underwent thermal pulsation therapy (LipiFlow; TearScience, Morrisville, NC) for the treatment of dry eye symptoms following laser vision correction. A standardized dry eye questionnaire, the Standard Patient Evaluation of Eye Dryness (SPEED II), was administered to all patients before and after thermal pulsation therapy. The primary outcome was patient-reported dry eye symptoms as measured by this questionnaire. The mean patient age was 49 years (interquartile range [IQR]: 38 to 60), 70% were female, and the primary refractive procedure was LASIK (n = 91, 83%) or photorefractive keratectomy (PRK) (n = 18, 17%). Patients underwent thermal pulsation therapy at a mean of 40.5 months (IQR: 27.6 to 55.0) after the primary procedure. The mean pre-therapy SPEED II questionnaire score was 17.5 (IQR: 14 to 21), with a reduced mean post-therapy score of 10.2 (IQR: 6 to 14; 95% confidence interval [CI]: 8.8 to 11.5, P < .001). Patients with PRK tended to report more improvement. At the follow-up clinical evaluation, objective improvements were noted in tear break-up time (+1.9 sec; 95% CI: 1.3 to 2.5), reduction in grade of meibomian gland dysfunction (-0.69; 95% CI: -0.54 to -0.84), and corneal staining (-0.74; 95% CI: -0.57 to -0.91). In this initial retrospective evaluation, a significant improvement in patient-reported dry eye symptoms was observed following thermal pulsation therapy. This treatment modality may have utility in the management of dry eye symptoms following laser vision correction, but further study is needed to define its role. [J Refract Surg. 2017;33(1):30-36.]. Copyright 2017, SLACK Incorporated.

  17. Development of Eye Dosimeter Using Additive Manufacturing Techniques to Monitor Occupational Eye Lens Exposures to Interventional Radiologists

    NASA Astrophysics Data System (ADS)

    Choi, JungHwan

    In this project, an eye dosimeter was designed for monitoring occupational lens of the eye exposures targeted to interventional radiologists who are often indirectly exposed to scattered radiation from the patient while performing image-guided procedures. The dosimeter was designed with a computer-aided design software to facilitate additive manufacturing techniques to make the dosimeter. The dosimeter consisted of three separate components that are attached to the hinges and the bridge of the occupational worker's protective eyewear. The produced dosimeter was radiologically calibrated to measure the lens dose on an anthropomorphic phantom of the human head. To supplement the physical design, an algorithm was written that prompts the user to input the element responses of the dosimeter, then estimates the average angle, energy, and resulting lens dose of the exposure by comparing the input with the data acquired during the dosimeter calibration procedure. The performance of the calibrated dosimeter (and the algorithm) was evaluated according to guidelines of the American National Standards Institute, and the dosimeter demonstrated a performance that was in compliance with the standard's performance criteria which suggests that the design of the eye dosimeter is feasible.

  18. Fixations to the eyes aids in facial encoding; covertly attending to the eyes does not.

    PubMed

    Laidlaw, Kaitlin E W; Kingstone, Alan

    2017-02-01

    When looking at images of faces, people will often focus their fixations on the eyes. It has previously been demonstrated that the eyes convey important information that may improve later facial recognition. Whether this advantage requires that the eyes be fixated, or merely attended to covertly (i.e. while looking elsewhere), is unclear from previous work. While attending to the eyes covertly without fixating them may be sufficient, the act of using overt attention to fixate the eyes may improve the processing of important details used for later recognition. In the present study, participants were shown a series of faces and, in Experiment 1, asked to attend to them normally while avoiding looking at either the eyes or, as a control, the mouth (overt attentional avoidance condition); or in Experiment 2 fixate the center of the face while covertly attending to either the eyes or the mouth (covert attention condition). After the first phase, participants were asked to perform an old/new face recognition task. We demonstrate that a) when fixations to the eyes are avoided during initial viewing then subsequent face discrimination suffers, and b) covert attention to the eyes alone is insufficient to improve face discrimination performance. Together, these findings demonstrate that fixating the eyes provides an encoding advantage that is not availed by covert attention alone. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Analysis of Fundus Shape in Highly Myopic Eyes by Using Curvature Maps Constructed from Optical Coherence Tomography

    PubMed Central

    Miyake, Masahiro; Yamashiro, Kenji; Akagi-Kurashige, Yumiko; Oishi, Akio; Tsujikawa, Akitaka; Hangai, Masanori; Yoshimura, Nagahisa

    2014-01-01

    Purpose To evaluate fundus shape in highly myopic eyes using color maps created through optical coherence tomography (OCT) image analysis. Methods We retrospectively evaluated 182 highly myopic eyes from 113 patients. After obtaining 12 lines of 9-mm radial OCT scans with the fovea at the center, the Bruch’s membrane line was plotted and its curvature was measured at 1-µm intervals in each image, which was reflected as a color topography map. For the quantitative analysis of the eye shape, mean absolute curvature and variance of curvature were calculated. Results The color maps allowed staphyloma visualization as a ring of green color at the edge and as that of orange-red color at the bottom. Analyses of mean and variance of curvature revealed that eyes with myopic choroidal neovascularization tended to have relatively flat posterior poles with smooth surfaces, while eyes with chorioretinal atrophy exhibited a steep, curved shape with an undulated surface (P<0.001). Furthermore, eyes with staphylomas and those without clearly differed in terms of mean curvature and the variance of curvature: 98.4% of eyes with staphylomas had mean curvature ≥7.8×10−5 [1/µm] and variance of curvature ≥0.26×10−8 [1/µm]. Conclusions We established a novel method to analyze posterior pole shape by using OCT images to construct curvature maps. Our quantitative analysis revealed that fundus shape is associated with myopic complications. These values were also effective in distinguishing eyes with staphylomas from those without. This tool for the quantitative evaluation of eye shape should facilitate future research of myopic complications. PMID:25259853

  20. Eyes only? Perceiving eye contact is neither sufficient nor necessary for attentional capture by face direction.

    PubMed

    Böckler, Anne; van der Wel, Robrecht P R D; Welsh, Timothy N

    2015-09-01

    Direct eye contact and motion onset both constitute powerful cues that capture attention. Recent research suggests that (social) gaze and (non-social) motion onset influence information processing in parallel, even when combined as sudden onset direct gaze cues (i.e., faces suddenly establishing eye contact). The present study investigated the role of eye visibility for attention capture by these sudden onset face cues. To this end, face direction was manipulated (away or towards onlooker) while faces had closed eyes (eliminating visibility of eyes, Experiment 1), wore sunglasses (eliminating visible eyes, but allowing for the expectation of eyes to be open, Experiment 2), and were inverted with visible eyes (disrupting the integration of eyes and faces, Experiment 3). Participants classified targets appearing on one of four faces. Initially, two faces were oriented towards participants and two faces were oriented away from participants. Simultaneous to target presentation, one averted face became directed and one directed face became averted. Attention capture by face direction (i.e., facilitation for faces directed towards participants) was absent when eyes were closed, but present when faces wore sunglasses. Sudden onset direct faces can, hence, induce attentional capture, even when lacking eye cues. Inverted faces, by contrast, did not elicit attentional capture. Thus, when eyes cannot be integrated into a holistic face representation they are not sufficient to capture attention. Overall, the results suggest that visibility of eyes is neither necessary nor sufficient for the sudden direct face effect. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Protect Their Eyes: An Eye Safety Guide for the Classroom.

    ERIC Educational Resources Information Center

    Ohio Society to Prevent Blindness, Columbus.

    This guide provides information on eye safety and aids educators, administrators, and supervisors in the development and implementation of eye safety programs. The American National Standards Institute (AMSI) requirements for both street and safety glasses; essential eyewear for safety in hazardous areas; the National Society to Prevent…

  2. A case of unilateral phthiriasis palpebrarum infestation involving the left eye.

    PubMed

    Ashraf, Mohammad; Waris, Abdul; Kumar, Ashwini; Akhtar, Nahid

    2014-06-06

    Phthiriasis palpebrarum is a rare cause of eyelid infestation. We report a case of unilateral phthiriasis palpebrarum. A 28-year-old man presented with moderate itching associated with lacrimation and irritation in the left eye. The initial evaluation of the patient revealed multiple white dots on the left upper eyelashes. Slit-lamp examination revealed multiple nits attached to the base and shaft of the cilia. There was no hyperaemia or discharge present in the conjunctiva and the cornea was clear and shiny. The right eye was perfectly normal. The patient was treated with moxifloxacin eye ointment and was completely cured in 1 week. 2014 BMJ Publishing Group Ltd.

  3. Different cellular effects of four anti-inflammatory eye drops on human corneal epithelial cells: independent in active components.

    PubMed

    Qu, Mingli; Wang, Yao; Yang, Lingling; Zhou, Qingjun

    2011-01-01

    To evaluate and compare the cellular effects of four commercially available anti-inflammatory eye drops and their active components on human corneal epithelial cells (HCECs) in vitro. The cellular effects of four eye drops (Bromfenac Sodium Hydrate Eye Drops, Pranoprofen Eye Drops, Diclofenac Sodium Eye Drops, and Tobramycin & Dex Eye Drops) and their corresponding active components were evaluated in an HCEC line with five in vitro assays. Cell proliferation and migration were measured using 3-(4,5)-dimethylthiahiazo (-z-y1)-3 5-di-phenytetrazoliumromide (MTT) assay and transwell migration assay. Cell damage was determined with the lactate dehydrogenase (LDH) assay. Cell viability and median lethal time (LT₅₀) were measured by 7-amino-actinomycin D (7-AAD) staining and flow cytometry analysis. Cellular effects after exposure of HCECs to the four anti-inflammatory eye drops were concentration dependent. The differences of cellular toxicity on cell proliferation became significant at lower concentrations (<0.002%). Diclofenac Sodium Eye Drops showed significant increasing effects on cell damage and viability when compared with the other three solutions. Tobramycin & Dex Eye Drops inhibited the migration of HCECs significantly. Tobramycin & Dex Eye Drops showed the quickest effect on cell viability: the LT₅₀ was 3.28, 9.23, 10.38, and 23.80 min for Tobramycin & Dex Eye Drops, Diclofenac Sodium Eye Drops, Pranoprofen Eye Drops, and Bromfenac Sodium Hydrate Eye Drops, respectively. However, the comparisons of cellular toxicity revealed significant differences between the eye drops and their active components under the same concentration. The corneal epithelial toxicity differences among the active components of the four eye drops became significant as higher concentration (>0.020%). The four anti-inflammatory eye drops showed different cellular effects on HCECs, and the toxicity was not related with their active components, which provides new reference for the

  4. Evaluation of Eye Protection Filters Used with Broad-Spectrum and Conventional LED Curing Lights.

    PubMed

    Soares, Carlos José; Rodrigues, Monise de Paula; Vilela, Andomar Bruno Fernandes; Rizo, Erick René Cerda; Ferreira, Lorraine Braga; Giannini, Marcelo; Price, Richard Bengt

    2017-01-01

    The high irradiance and the different emission spectra from contemporary light curing units (LCU) may cause ocular damage. This study evaluated the ability of 15 eye protection filters: 2 glasses, 1 paddle design, and 12 dedicated filters to block out harmful light from a monowave (HP-3M ESPE) and a broad-spectrum (Valo, Ultradent) LED LCU. Using the anterior sensor in the MARC-Patient Simulator (BlueLight Analytics) the irradiance that was delivered through different eye protection filters was measured three times. The LCUs delivered a similar irradiance to the top of the filter. The mean values of the light that passed through the filters as percent of the original irradiance were analyzed using two-way ANOVA followed by Tukey test (a= 0.05). The emission spectra from the LCUs and through the filters were also obtained. Two-way ANOVA showed that the interaction between protective filters and LCUs significantly influenced the amount of light transmitted (p< 0.001). Tukey test showed that the amount of light transmitted through the protective filters when using the HP-3M-ESPE was significantly greater compared to when using the Valo, irrespective of the protective filter tested. When using the HP-3M-ESPE, the Glasses filter allowed significantly more light through, followed by XL 3000, ORTUS, Google Professional, Gnatus filters. The Valo filter was the most effective at blocking out the harmful light. Some protective filters were less effective at blocking the lower wavelengths of light (<420 nm). However, even in the worst scenario, the filters were able to block at least 97% of the irradiance.

  5. Singapore Indian Eye Study-2: methodology and impact of migration on systemic and eye outcomes.

    PubMed

    Sabanayagam, Charumathi; Yip, Wanfen; Gupta, Preeti; Mohd Abdul, Riswana Bb; Lamoureux, Ecosse; Kumari, Neelam; Cheung, Gemmy Cm; Cheung, Carol Y; Wang, Jie Jin; Cheng, Ching-Yu; Wong, Tien Yin

    2017-11-01

    Asian Indians are the fastest growing migration groups in the world. Studies evaluating the impact of migration on disease outcomes in this population are rare. We describe the methodology of the Singapore Indian Eye Study-2 (SINDI-2) aimed to evaluate the impact of migration status on diabetic retinopathy and other major age-related eye diseases in Asian Indians living in an urban environment. Population-based cohort study. A total of 2200 adults had participated in baseline SINDI (2007-2009, mean age [range] = 57.8 [42.7-84.1] years) and SINDI-2 (2013-2015, 56.5 [48.4-90.2] years). Participants were classified as 'first generation' if they were Indian residents born outside of Singapore and as 'second-generation' immigrants (59.7% in SINDI vs. 63.6% in SINDI-2) if they were born in Singapore. Response rate, participant characteristics and prevalence of systemic diseases were stratified by migration status. Of the 2914 eligible SINDI participants invited to participate, 2200 participated in SINDI-2 (response rate of 75.2%). In both SINDI and SINDI-2, compared with first-generation immigrants, second-generation immigrants were younger, less likely to have income <1000 SGD, had lower levels of pulse pressure, higher levels of high-density lipoprotein cholesterol, had lower prevalence of hypertension and chronic kidney disease and had higher prevalence of current smoking and obesity (all P < 0.05). In both SINDI and SINDI-2, second-generation immigrants had lower prevalence of cardiovascular risk factors except smoking and obesity compared with first-generation immigrants. The final report will confirm if these differences between generations are evident with regard to eye diseases. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  6. Effect of Intravenous Mannitol on Intraocular Pressure in Vitrectomized Silicone-Oil-Filled Eyes.

    PubMed

    Takkar, Brijesh; Chandra, Parijat; Shah, Ritu; Bhatia, Indrish; Roy, Sangeeta; Sihota, Ramanjit

    2017-01-01

    To evaluate the effect of intravenous mannitol (IVM) on intraocular pressure (IOP) in vitrectomized eyes. Thirty-one patients with raised IOP after retinal surgery with silicone oil injection were included. Patients were administered IVM (20% solution, 1g/Kg, over 30 minutes) and IOP was noted at regular intervals. IOP reduction in vitrectomized eyes (Group 1) was compared with the normal eyes (Group 2). Percentage IOP reduction was higher in Group 1 than in Group 2 at all time intervals, 24.5% vs. 19.2% at 15 minutes (p=0.34), 22.6% vs. 9.8% at 45 minutes (p=0.003), 19.1% vs. 9.9% at two hours (p=0.023), and 16.1% vs. 7.8% at four hours (p=0.04), respectively. In Group 1, 40% eyes had an IOP reduction of 2-6 mmHg while 30% eyes had IOP reduction >6 mmHg at four hours post-IVM. IVM is useful for short-term IOP reduction in vitrectomized eyes. IOP reduction is independent of baseline IOP, and sustained and higher as compared to normal eyes.

  7. High incidence of dry eye in young children with allergic conjunctivitis in Southwest China.

    PubMed

    Chen, Lin; Pi, Lianhong; Fang, Jing; Chen, Xinke; Ke, Ning; Liu, Qing

    2016-12-01

    To identify the prevalence of dry eye in pediatric population with allergic conjunctivitis in Southwest China. A single-centre, prospective, case-control study conducted between May 2015 and December 2015 included 40 children, 3-6 years of age, with seasonal allergic conjunctivitis (SAC) or perennial allergic conjunctivitis (PAC) and 40 age- and gender-matched children undergoing medical healthy examination without history of allergy or dry eye as a control. A dry eye score system (DESS) was administered to both groups. Slit-lamp examinations including tear film break-up time (TFBUT) and fluorescent corneal staining (FCS) were performed. Correlation analyses were performed to evaluate associations between measures of dry eye and signs and symptoms of AC. The prevalence of dry eye was 97.5% (78/80 eyes) in cases and 27.50% (22/80 eyes) in controls. Mean DESS score was 4.75 ± 2.22 in the case group and 0.80 ± 1.22 in the control group (p < 0.001). Symptoms of dry eye in the case group were mild (<6). Mean tear film break-up time was 6.54 ± 1.48 seconds in the case group and 10.04 ± 1.79 seconds in the control group (p < 0.001). Mean FCS scores were 0.79 ± 1.34 and 0.21 ± 0.57, respectively (p = 0.001). The DESS score and TFBUT were both associated with the duration of allergic conjunctivitis. The incidence of dry eye assessed by TFBUT was higher in young children with SAC and PAC than in controls. However, subjective symptoms of dry eye (DESS) were inconsistent with objective signs, indicating that close attention should be paid to the evaluation and treatment of dry eye in pediatric population with AC. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Injury surveillance in construction: eye injuries.

    PubMed

    Welch, L S; Hunting, K L; Mawudeku, A

    2001-07-01

    Occupational eye injuries are both common and preventable. About 20% of occupational eye injuries occur in construction. To investigate the nature of eye injuries among construction workers, we analyzed a large data set of construction worker injuries. In addition, we interviewed 62 workers with eye injuries to further explore circumstances of eye injury and workers' attitudes and behavior toward the use of eye protection. Eleven percent (363 cases) of the 3,390 construction workers in our data set were treated for eye injuries. Welders, plumbers, insulators, painters/glaziers, supervisors, and electricians had a higher proportion of all injuries due to eye injuries than other trades. Nearly half of the diagnoses were abrasions (46%) followed by foreign objects or splash in the eye (29%), conjunctivitis (10%), and burns (5%). In the interviews with 62 workers, we found that employers very frequently required eye protection for all tasks or for high-risk tasks, and workers report wearing eye protection regularly. However, most did not wear eye protection with top and side shields; if we believe the injuries occurred because a particle or liquid passed between the glasses and the workers' faces, increased use of goggles or full shields would have prevented two-thirds of this group of injuries.

  9. Comparison of in vitro eye irritation potential by bovine corneal opacity and permeability (BCOP) assay to erythema scores in human eye sting test of surfactant-based formulations.

    PubMed

    Cater, Kathleen C; Harbell, John W

    2008-01-01

    The bovine corneal opacity and permeability (BCOP) assay can be used to predict relative eye irritation potential of surfactant-based personal care formulations relative to a corporate benchmark. The human eye sting test is typically used to evaluate product claims of no tears/no stinging for children's bath products. A preliminary investigation was conducted to test a hypothesis that the BCOP assay could be used as a prediction model for relative ranking of human eye irritation responses under conditions of a standard human eye sting test to surfactant-based formulations. BCOP assays and human eye sting tests were conducted on 4 commercial and 1 prototype body wash (BW) developed specifically for children or as mild bath products. In the human eye sting test, 10 mul of a 10% dosing solution is instilled into one eye of each panelist (n = 20), and the contralateral eye is dosed with sterile water as a control. Bulbar conjunctival erythema responses of each eye are graded at 30 seconds by an ophthalmologist. The BCOP assay permeability values (optical density at 490 nm [OD(490)]) for the 5 BWs ranged from 0.438 to 1.252 (i.e., least to most irritating). By comparison, the number of panelists exhibiting erythema responses (mild to moderately pink) ranged from 3 of 20 panelists for the least irritating BW to 10 of 20 panelists for the most irritating BW tested. The relative ranking of eye irritation potential of the 5 BWs in the BCOP assay compares favorably with the relative ranking of the BWs in the human eye sting test. Based on these findings, the permeability endpoint of the BCOP assay, as described for surfactant-based formulations, showed promise as a prediction model for relative ranking of conjunctival erythema responses in the human eye. Consequently, screening of prototype formulations in the BCOP assay would allow for formula optimization of mild bath products prior to investment in a human eye sting test.

  10. Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation.

    PubMed

    Zhang, Di; Cagnon, Chris H; Villablanca, J Pablo; McCollough, Cynthia H; Cody, Dianna D; Stevens, Donna M; Zankl, Maria; Demarco, John J; Turner, Adam C; Khatonabadi, Maryam; McNitt-Gray, Michael F

    2012-02-01

    The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques. Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated. CTDI(vol) for each scanner was obtained from the scanner console. Dose reduction to the eye lens was evaluated for various gantry tilt angles as well as scan locations. Peak skin dose and eye lens dose ranged from 81 mGy to 348 mGy, depending on the scanner and protocol used. Peak skin dose and eye lens dose were observed to be 66-79% and 59-63%, respectively, of the CTDI(vol) values reported by the scanners. The eye lens dose was significantly reduced when the eye lenses were not directly irradiated. CTDI(vol) should not be interpreted as patient dose; this study has shown it to overestimate dose to the skin or eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy.

  11. Femtosecond Laser in situ Keratomileusis Flap Creation in Narrow Palpebral Fissure Eyes without Suction.

    PubMed

    Chang, John S M; Law, Antony K P; Ng, Jack C M; Cheng, May S Y

    2017-01-01

    To evaluate a surgical technique used in eyes with narrow palpebral fissure undergoing femtosecond laser flap creation without suction during laser in situ keratomileusis (LASIK). All data of 2 patient groups were collected through chart review. Group 1 consisted of 6 eyes with narrow palpebral fissure in which the suction ring was manually fixated and femtosecond laser was applied accordingly. Thirty comparison cases were randomly drawn from among eyes that underwent a standard LASIK procedure matched for age and preoperative refraction (group 2). Only 1 eye of each patient was selected to compare the refractive and visual outcomes between groups. In all group 1 eyes, the flaps were created successfully with manual fixation of the suction ring without suction. No eyes lost 2 or more lines of vision. No significant difference was found in the safety and refractive outcomes between groups. Manual fixation of the suction ring in eyes with narrow palpebral fissure without suction was feasible for flap creation during LASIK.

  12. Artificial eye for in vitro experiments of laser light interaction with aqueous media

    NASA Astrophysics Data System (ADS)

    Cain, Clarence P.; Noojin, Gary D.; Hammer, Daniel X.; Thomas, Robert J.; Rockwell, Benjamin A.

    1997-01-01

    An artificial eye has been designed and assembled that mimics the focusing geometry of the living eye. The artificial eye's focusing characteristics are measured and compared with those of the in vivo system. The artificial eye is used to measure several nonlinear optical phenomena that may have an impact on the laser damage thresholds of the retina produced by ultrashort laser pulses. We chose a focal length of 17 mm to simulate the rhesus monkey eye, with a visual cone angle of 8.4 deg for a 2.5-mm diameter laser beam input. The measured focal point image diameter was 5.6 plus or minus 1 micrometer, which was 1.5 times the calculated diffraction-limited image diameter. This focusing system had the best M2 of all the systems evaluated. We used the artificial eye to measure the threshold for laser- induced breakdown, stimulated Brillouin scattering, super- continuum generation, and pulse temporal broadening due to group velocity dispersion.

  13. Inflammation in dry eye.

    PubMed

    Stern, Michael E; Pflugfelder, Stephen C

    2004-04-01

    Dry eye is a condition of altered tear composition that results from a diseased or dysfunctional lacrimal functional unit. Evidence suggests that inflammation causes structural alterations and/or functional paralysis of the tear-secreting glands. Changes in tear composition resulting from lacrimal dysfunction, increased evaporation and/or poor clearance have pro-inflammatory effects on the ocular surface. This inflammation is responsible in part for the irritation symptoms, ocular surface epithelial disease, and altered corneal epithelial barrier function in dry eye. Anti-inflammatory therapies for dry eye target one or more of the inflammatory mediators/pathways that have been identified in dry eye.

  14. Safety and pharmokinetics of triamcinolone hexacetonide in rabbit eyes.

    PubMed

    Abd-El-Barr, Muhammad M; Albini, Thomas A; Carvounis, Petros E; He, Feng; Manzano, Roberta P A; Chevez-Barrios, Patricia; Wensel, Theodore G; Wu, Samuel M; Holz, Eric R

    2008-04-01

    The aim of this study was to evaluate whether intravitreal triamcinolone hexacetonide (TH) is a safe, longer lasting alternative to intravitreal triamcinolone acetonide (TA) in the rabbit eye. Three groups, each comprising of 15 Dutch-belted rabbits, received a unilateral injection of 0.1 mL of drug and 0.1 mL of physiologic salt solution in the fellow eye. Group I received TA, group II received commercially available TH, and group III received reformulated iso-osmolar triamcinolone hexacetonide (rTH). Simultaneous bilateral dark-adapted electroretinography was performed following the injection. Retinal morphology was assessed by using histopathology in each group enucleated 12 weeks after injection. High-performance liquid chromatography of vitreous isolated from the enucleated eyes was used to determine drug concentrations. A significant reduction in saturated a-wave and maximal scotopic b-wave was observed in the group II eyes relative to the fellow control eyes at both 2 and 12 weeks postinjection (P < 0.001 for each comparison) but not in the other groups. Histopathology showed no differences between drug-injected eyes and fellow control eyes in groups I and III, but in group II there was severe degeneration of all retina layers. In group I, the drug half-life was 17.7 +/- 1.7 days, group II 44 +/- 13 days, and group III 12.8 +/- 2.3 days. The half-life of commercially available TH in the vitreous is double that of TA, but the former is toxic to the retina in this rabbit model. Reformulated iso-osmolar TH showed no evidence of deleterious effects to retina function or structure but had a similar half-life to TA.

  15. Diagnostic accuracy of eye movements in assessing pedophilia.

    PubMed

    Fromberger, Peter; Jordan, Kirsten; Steinkrauss, Henrike; von Herder, Jakob; Witzel, Joachim; Stolpmann, Georg; Kröner-Herwig, Birgit; Müller, Jürgen Leo

    2012-07-01

    Given that recurrent sexual interest in prepubescent children is one of the strongest single predictors for pedosexual offense recidivism, valid and reliable diagnosis of pedophilia is of particular importance. Nevertheless, current assessment methods still fail to fulfill psychometric quality criteria. The aim of the study was to evaluate the diagnostic accuracy of eye-movement parameters in regard to pedophilic sexual preferences. Eye movements were measured while 22 pedophiles (according to ICD-10 F65.4 diagnosis), 8 non-pedophilic forensic controls, and 52 healthy controls simultaneously viewed the picture of a child and the picture of an adult. Fixation latency was assessed as a parameter for automatic attentional processes and relative fixation time to account for controlled attentional processes. Receiver operating characteristic (ROC) analyses, which are based on calculated age-preference indices, were carried out to determine the classifier performance. Cross-validation using the leave-one-out method was used to test the validity of classifiers. Pedophiles showed significantly shorter fixation latencies and significantly longer relative fixation times for child stimuli than either of the control groups. Classifier performance analysis revealed an area under the curve (AUC) = 0.902 for fixation latency and an AUC = 0.828 for relative fixation time. The eye-tracking method based on fixation latency discriminated between pedophiles and non-pedophiles with a sensitivity of 86.4% and a specificity of 90.0%. Cross-validation demonstrated good validity of eye-movement parameters. Despite some methodological limitations, measuring eye movements seems to be a promising approach to assess deviant pedophilic interests. Eye movements, which represent automatic attentional processes, demonstrated high diagnostic accuracy. © 2012 International Society for Sexual Medicine.

  16. Fracture Analyses of Cracked Delta Eye Plates in Ship Towing

    NASA Astrophysics Data System (ADS)

    Huang, Xiangbing; Huang, Xingling; Sun, Jizheng

    2018-01-01

    Based on fracture mechanics, a safety analysis approach is proposed for cracked delta eye plates in ship towing. The static analysis model is presented when the delta eye plate is in service, and the fracture criterion is introduced on basis of stress intensity factor, which is estimated with domain integral method. Subsequently, three-dimensional finite element analyses are carried out to obtain the effective stress intensity factors, and a case is studied to demonstrate the reasonability of the approach. The results show that the classical strength theory is not applicable to evaluate the cracked plate while fracture mechanics can solve the problem very well, and the load level, which a delta eye plate can carry on, decreases evidently when it is damaged.

  17. Automated eye blink detection and correction method for clinical MR eye imaging.

    PubMed

    Wezel, Joep; Garpebring, Anders; Webb, Andrew G; van Osch, Matthias J P; Beenakker, Jan-Willem M

    2017-07-01

    To implement an on-line monitoring system to detect eye blinks during ocular MRI using field probes, and to reacquire corrupted k-space lines by means of an automatic feedback system integrated with the MR scanner. Six healthy subjects were scanned on a 7 Tesla MRI whole-body system using a custom-built receive coil. Subjects were asked to blink multiple times during the MR-scan. The local magnetic field changes were detected with an external fluorine-based field probe which was positioned close to the eye. The eye blink produces a field shift greater than a threshold level, this was communicated in real-time to the MR system which immediately reacquired the motion-corrupted k-space lines. The uncorrected images, using the original motion-corrupted data, showed severe artifacts, whereas the corrected images, using the reacquired data, provided an image quality similar to images acquired without blinks. Field probes can successfully detect eye blinks during MRI scans. By automatically reacquiring the eye blink-corrupted data, high quality MR-images of the eye can be acquired. Magn Reson Med 78:165-171, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  18. Dry Eye Syndrome in Non-Exophthalmic Graves' Disease.

    PubMed

    Bruscolini, A; Abbouda, A; Locuratolo, N; Restivo, L; Trimboli, P; Romanelli, F

    2015-01-01

    The present study aims to assess qualitative and quantitative characteristics of tear film and corneal related impairment and to evaluate the quality of life in a cohort of non-exophthalmic Graves' disease (GD) patients. The series comprised 50 eyes from 25 newly diagnosed GD patients with no proptosis. As control group, 56 eyes of 28 thyroid disease-free subjects were enrolled. The results of Schirmer I and II, break-up time, and Oxford scheme showed a significant difference between GD and controls. By ocular surface disease index (OSDI) questionnaire, eleven (44%) GD patients had normal ocular surface, while two (8%) had mild, four (16%) had moderate, and eight (32%) had severe dry eye. The mean score of the OSDI in the GD group was significantly (p < 0.001) higher with respect to the control group. This study shows that the tear film and cornea are damaged in newly non-exophthalmic GD subjects.

  19. [Changes of axial dimensions of the eye during growth in emmetropia, myopia and hyperopia].

    PubMed

    Katuzny, Bartłomiej J; Koszewska-Kołodziejczak, Aleksandra

    2005-01-01

    The aim ot this study was to evaluate changes ot axial dimensions ot the eye during growth in emmetropia, myopia and hyperopia. We examined 183 children (363 eyes) aged 4 to 19 with emmetropia, myopia and hyperopia. All measurements were performed after cycloplegia with 1% tropicamidum (Polfa Warszawa). Total and corneal refraction was examined with autokeratorefractometer (Nikon NRK-8000). Then we used ultrasound biometer Ocuscan (Alcon, USA), to measure axial length of the eye, axial length of the vitreous cavity, axial dimension of the lens and axial depth of the anterior chamber. 1. Growth of the axial length of the emmetropic eyes is finished at the age of 12, in hyperopic eyes in the age of 11 and in myopic eyes growth is proportional until the age of 14 and then significantly accelerates. 2. Growth of the axial length is mainly caused by increasing axial length of vitreous cavity. A little role in human eye growth is also played by increasing depth of the anterior chamber. 3. Between 4 and 19 years old, mean cycloplegic axial dimension of the lens is slightly decreasing in emmetropic and hyperopic eyes, whereas in myopic eyes is constant.

  20. Comparison of visual function between phakic eyes and pseudophakic eyes with a monofocal intraocular lens.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hayashi, Hideyuki

    2010-01-01

    To compare all-distance visual acuity and contrast visual acuity with and without glare (glare visual acuity) between phakic eyes with a clear lens and pseudophakic eyes with a monofocal intraocular lens. Hayashi Eye Hospital, Fukuoka, Japan. This study comprised phakic), pseudophakic eyes in 4 age groups (40s, 50s, 60s, 70s). Corrected visual acuity from far to near, contrast visual acuity, and glare visual acuity were examined. The mean corrected intermediate and near visual acuities were significantly better in phakic eyes than in pseudophakic eyes in patients in their 40s and 50s (Peyes achieved a corrected visual acuity of 20/29 or 20/40 was greater in phakic eyes than in pseudophakic eyes in the 40s and 50s age groups (Peyes was greater than in pseudophakic eyes; the region was similar in patients in their 60s and 70s. Because contrast sensitivity with and without glare was similar at all ages, visual function appeared to be comparable in patients 60 years and older. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Aversive eye gaze during a speech in virtual environment in patients with social anxiety disorder.

    PubMed

    Kim, Haena; Shin, Jung Eun; Hong, Yeon-Ju; Shin, Yu-Bin; Shin, Young Seok; Han, Kiwan; Kim, Jae-Jin; Choi, Soo-Hee

    2018-03-01

    One of the main characteristics of social anxiety disorder is excessive fear of social evaluation. In such situations, anxiety can influence gaze behaviour. Thus, the current study adopted virtual reality to examine eye gaze pattern of social anxiety disorder patients while presenting different types of speeches. A total of 79 social anxiety disorder patients and 51 healthy controls presented prepared speeches on general topics and impromptu speeches on self-related topics to a virtual audience while their eye gaze was recorded. Their presentation performance was also evaluated. Overall, social anxiety disorder patients showed less eye gaze towards the audience than healthy controls. Types of speech did not influence social anxiety disorder patients' gaze allocation towards the audience. However, patients with social anxiety disorder showed significant correlations between the amount of eye gaze towards the audience while presenting self-related speeches and social anxiety cognitions. The current study confirms that eye gaze behaviour of social anxiety disorder patients is aversive and that their anxiety symptoms are more dependent on the nature of topic.

  2. The Minnesota Grading System Using Fundus Autofluorescence of Eye Bank Eyes: A Correlation To Age-Related Macular Degeneration (An AOS Thesis)

    PubMed Central

    Olsen, Timothy W.

    2008-01-01

    Purpose To establish a grading system of eye bank eyes using fundus autofluorescence (FAF) and identify a methodology that correlates FAF to age-related macular degeneration (AMD) with clinical correlation to the Age-Related Eye Disease Study (AREDS). Methods Two hundred sixty-two eye bank eyes were evaluated using a standardized analysis of FAF. Measurements were taken with the confocal scanning laser ophthalmoscope (cSLO). First, high-resolution, digital, stereoscopic, color images were obtained and graded according to AREDS criteria. With the neurosensory retina removed, mean FAF values were obtained from cSLO images using software analysis that excludes areas of atrophy and other artifact, generating an FAF value from a grading template. Age and AMD grade were compared to FAF values. An internal fluorescence reference standard was tested. Results Standardization of the cSLO machine demonstrated that reliable data could be acquired after a 1-hour warm-up. Images obtained prior to 1 hour had falsely elevated levels of FAF. In this initial analysis, there was no statistical correlation of age to mean FAF. There was a statistically significant decrease in FAF from AREDS grade 1, 2 to 3, 4 (P < .0001). An internal fluorescent standard may serve as a quantitative reference. Conclusions The Minnesota Grading System (MGS) of FAF (MGS-FAF) establishes a standardized methodology for grading eye bank tissue to quantify FAF compounds in the retinal pigment epithelium and correlate these findings to the AREDS. Future studies could then correlate specific FAF to the aging process, histopathology AMD phenotypes, and other maculopathies, as well as to analyze the biochemistry of autofluorescent fluorophores. PMID:19277247

  3. Evolution of the vertebrate eye: opsins, photoreceptors, retina and eye cup

    PubMed Central

    Lamb, Trevor D.; Collin, Shaun P.; Pugh, Edward N.

    2011-01-01

    Charles Darwin appreciated the conceptual difficulty in accepting that an organ as wonderful as the vertebrate eye could have evolved through natural selection. He reasoned that if appropriate gradations could be found that were useful to the animal and were inherited, then the apparent difficulty would be overcome. Here, we review a wide range of findings that capture glimpses of the gradations that appear to have occurred during eye evolution, and provide a scenario for the unseen steps that have led to the emergence of the vertebrate eye. PMID:18026166

  4. Evolution of the vertebrate eye: opsins, photoreceptors, retina and eye cup.

    PubMed

    Lamb, Trevor D; Collin, Shaun P; Pugh, Edward N

    2007-12-01

    Charles Darwin appreciated the conceptual difficulty in accepting that an organ as wonderful as the vertebrate eye could have evolved through natural selection. He reasoned that if appropriate gradations could be found that were useful to the animal and were inherited, then the apparent difficulty would be overcome. Here, we review a wide range of findings that capture glimpses of the gradations that appear to have occurred during eye evolution, and provide a scenario for the unseen steps that have led to the emergence of the vertebrate eye.

  5. Evidence of common and separate eye and hand accumulators underlying flexible eye-hand coordination

    PubMed Central

    Jana, Sumitash; Gopal, Atul

    2016-01-01

    Eye and hand movements are initiated by anatomically separate regions in the brain, and yet these movements can be flexibly coupled and decoupled, depending on the need. The computational architecture that enables this flexible coupling of independent effectors is not understood. Here, we studied the computational architecture that enables flexible eye-hand coordination using a drift diffusion framework, which predicts that the variability of the reaction time (RT) distribution scales with its mean. We show that a common stochastic accumulator to threshold, followed by a noisy effector-dependent delay, explains eye-hand RT distributions and their correlation in a visual search task that required decision-making, while an interactive eye and hand accumulator model did not. In contrast, in an eye-hand dual task, an interactive model better predicted the observed correlations and RT distributions than a common accumulator model. Notably, these two models could only be distinguished on the basis of the variability and not the means of the predicted RT distributions. Additionally, signatures of separate initiation signals were also observed in a small fraction of trials in the visual search task, implying that these distinct computational architectures were not a manifestation of the task design per se. Taken together, our results suggest two unique computational architectures for eye-hand coordination, with task context biasing the brain toward instantiating one of the two architectures. NEW & NOTEWORTHY Previous studies on eye-hand coordination have considered mainly the means of eye and hand reaction time (RT) distributions. Here, we leverage the approximately linear relationship between the mean and standard deviation of RT distributions, as predicted by the drift-diffusion model, to propose the existence of two distinct computational architectures underlying coordinated eye-hand movements. These architectures, for the first time, provide a computational basis for

  6. Opposing interactions between homothorax and Lobe define the ventral eye margin of Drosophila eye

    PubMed Central

    Singh, Amit; Tare, Meghana; Kango-Singh, Madhuri; Son, Won-Seok; Cho, Kyung-Ok; Choi, Kwang-wook

    2011-01-01

    SUMMARY Patterning in multi-cellular organisms involves progressive restriction of cell fates by generation of boundaries to divide an organ primordium into smaller fields. We have employed the Drosophila eye model to understand the genetic circuitry responsible for defining the boundary between the eye and the head cuticle on the ventral margin. The default state of the early eye is ventral and depends on the function of Lobe (L) and the Notch ligand Serrate (Ser). We identified homothorax (hth) as a strong enhancer of the L mutant phenotype of loss of ventral eye. Hth is a MEIS class gene with a highly conserved Meis-Hth (MH) domain and a homeodomain (HD). Hth is known to bind Extradenticle (Exd) via its MH domain for its nuclear translocation. Loss-of-function of hth, a negative regulator of eye, results in ectopic ventral eye enlargements. This phenotype is complementary to the L mutant phenotype of loss-of-ventral eye. However, if L and hth interact during ventral eye development remains unknown. Here we show that (i) L acts antagonistically to hth, (ii) Hth is upregulated in the L mutant background, and (iii) MH domain of Hth is required for its genetic interaction with L, while its homeodomain is not, (iv) in L mutant background ventral eye suppression function of Hth involves novel MH domain-dependent factor(s), (v) Nuclear localization of Exd is not sufficient to mediate the Hth function in the L mutant background. Further, Exd is not a critical rate-limiting factor for the Hth function. Thus, optimum levels of L and Hth are required to define the boundary between the developing eye and head cuticle on the ventral margin. PMID:21920354

  7. Dry eye syndrome

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/000426.htm Dry eye syndrome To use the sharing features on this page, ... second-hand smoke exposure Cold or allergy medicines Dry eye can also be caused by: Heat or ... Symptoms may include: Blurred vision Burning, itching, ...

  8. Video-Based Eye Tracking in Sex Research: A Systematic Literature Review.

    PubMed

    Wenzlaff, Frederike; Briken, Peer; Dekker, Arne

    2015-12-21

    Although eye tracking has been used for decades, it has gained popularity in the area of sex research only recently. The aim of this article is to examine the potential merits of eye tracking for this field. We present a systematic review of the current use of video-based eye-tracking technology in this area, evaluate the findings, and identify future research opportunities. A total of 34 relevant studies published between 2006 and 2014 were identified for inclusion by means of online databases and other methods. We grouped them into three main areas of research: body perception and attractiveness, forensic research, and sexual orientation. Despite the methodological and theoretical differences across the studies, eye tracking has been shown to be a promising tool for sex research. The article suggests there is much potential for further studies to employ this technique because it is noninvasive and yet still allows for the assessment of both conscious and unconscious perceptional processes. Furthermore, eye tracking can be implemented in investigations of various theoretical backgrounds, ranging from biology to the social sciences.

  9. Comparison of noncontact infrared and remote sensor thermometry in normal and dry eye patients.

    PubMed

    Singh, G; Singh Bhinder, H

    To evaluate the role of closed chamber infrared and remote sensor thermometry in normal and dry eye patients. The study was conducted on 51 dry eye cases (102 eyes), 26 men and 25 women aged 19 to 65 years (35.3614.36), and 51 normal (102 eyes) age- and sex-matched control subjects. The criteria for dry eye were Schirm e r-1 (<10 m/5 min), FTBUT (<10 sec), nd lissamine green score (>2). The remote sensor and infrared thermometry was done in losed chamber around the eye in closed and open eye positions. In normal eyes, closed chamber infrared thermometry recorded temperature 34.770.37 C in closed eye position and 35.020.39 C in open eye position as compared to 27.912.46 C in closed eye position and 28.012.46 C in open position with remote sensor thermometry. The difference in temperature from closed to open position was 0.250.90 C in infrared thermometry and 0.100.00 C with remote sensor thermometry, which was statistically significant (p<0.0000). In dry eye, the infrared therm o m e t ry recorded 35.080.61 C temperature in closed eye position and 35.530.63 C in open eye position as compared to 27.412.48 C in open and closed eye position with remote sensor thermometry. The difference in temperature from closed to open eye position was 0.450.14 C (p<0.0000) with infrared thermometry as compared to no change 0.000.00 C with remote sensor thermometry (p<0.0000). Remote sensor thermometry proved better for diagnosis of dry eye disease as it showed no change in temperature under closed chamber in closed and open position (p=0.0000). Infrared thermometry was better in recording the absolute temperature from any point on the eye.

  10. Ultrasonographic biometry of the normal eye of the Persian cat.

    PubMed

    Mirshahi, A; Shafigh, S H; Azizzadeh, M

    2014-07-01

    To describe the normal ultrasonographic biometry of the Persian cat's eyes using B-mode ultrasonography. In a cross-sectional study, 20 healthy Persian cats with no history of previous ophthalmic disease were examined. Ocular biometry of the left and right eyes was measured using B-mode ultrasonography. Comparison of the average measurements between left and right eyes and between vertical and horizontal planes was performed using paired-sample t test. Correlation of ocular parameters with sex, age, head circumference and eye colour was evaluated. Mean ± standard deviation (SD) measurements of the ocular structures of anterior chamber, lens thickness, vitreous chamber and anterior to posterior dimension of the globe in 40 eyes were 4.1 ± 0.7, 7.7 ± 0.5, 8.2 ± 0.4 and 20.7 ± 1.0 mm, respectively. No significant difference was found between the ocular biometry of the left and right eyes or the horizontal and vertical planes. Of the ocular parameters, the following had a significant positive correlation with head circumference: axial globe length, anterior chamber and lens thickness. The vitreous body had a positive correlation with age. Regarding the breed predisposition of Persian cats to ocular problems, the present study provides baseline information for further clinical investigations of ocular abnormalities using B-mode ultrasonography. © 2014 Australian Veterinary Association.

  11. Meibomian gland dropout in patients with dry eye disease in China.

    PubMed

    Feng, Yun; Gao, Ziqing; Feng, Kang; Qu, Hongqiang; Hong, Jing

    2014-10-01

    To examine the morphological changes in the meibomian glands of eyes of patients with dry eye disease using the non-contact infrared meibography system and to assess their relationship with meibomian dropout, signs, and tear-film function. Subjects included 264 randomly selected patients (528 eyes) suffering from dry eye disease (95 males, 169 females; age range, 7-85 years; mean male age, 39.83 ± 19.17 years; mean female age, 46.16 ± 17.38 years). Tear-film break-up time (BUT) was measured and tear-film production was evaluated by the Schirmer test I (SIT). Subjective symptoms were also scored. The upper and lower eyelids were turned over, and the meibomian glands were observed using the non-contact meibography system. Partial or complete loss of the meibomian glands (meibomian dropout) was scored for each eyelid from grade 0 (no loss) through grade 3 (lost area was >2/3 of the total meibomian gland area). The average SIT result was 6.71 ± 6.13 mm (range 0-30 mm) and that for BUT was 3.13 ± 2.39 s (range 0-10 s). The average fluorescein staining score was 4.25 ± 4.05 (range 0-12). In addition, the mean meibomian gland photographic score was 4.35 ± 1.39. The correlation between the meibomian gland photographic scores and various ocular surface examinations were evaluated using Kendall's correlation. SIT and BUT were significantly negatively correlated with the meibomian gland photographic score, whereas corneal fluorescein staining was positively correlated. The results suggest a large proportion of meibomian dropout cases among patients with dry eye disease, indicating that treatment targeted at the meibomian gland will become an important direction for treating dry eye disease. Meibography is recommended as a routine test for dry eye disease.

  12. Eye-Safe Lidar

    NASA Technical Reports Server (NTRS)

    Byer, Robert L.

    1989-01-01

    Laser infrared radar (lidar) undergoing development harmless to human eyes, consists almost entirely of solid-state components, and offers high range resolution. Operates at wavelength of about 2 micrometers. If radiation from such device strikes eye, almost completely absorbed by cornea without causing damage, even if aimed directly at eye. Continuous-wave light from laser oscillator amplified and modulated for transmission from telescope. Small portion of output of oscillator fed to single-mode fiber coupler, where mixed with return pulses. Intended for remote Doppler measurements of winds and differential-absorption measurements of concentrations of gases in atmosphere.

  13. Dry Eyes and Glaucoma: Double Trouble

    MedlinePlus

    ... Involved News About Us Donate In This Section Dry Eyes and Glaucoma: Double Trouble email Send this article ... eye disease bothers the patient more. What Causes Dry Eye Syndrome? Dry eye can be caused by many ...

  14. A comparison of the self-reported dry eye practices of New Zealand optometrists and ophthalmologists.

    PubMed

    Xue, Ally L; Downie, Laura E; Ormonde, Susan E; Craig, Jennifer P

    2017-03-01

    The aim of this cross-sectional survey was to evaluate the self-reported clinical practices of New Zealand optometrists and ophthalmologists with respect to the diagnosis and management of dry eye disease. It also sought to compare these behaviours with the current research evidence base. An anonymous survey was distributed electronically to New Zealand eye care clinicians (optometrists n = 614, ophthalmologists n = 113) to determine practitioner interest in dry eye disease, practice experience, practice modality, preferred diagnostic and management strategies, and information used to guide patient care. Respondents from both professions (response rates, optometrists: 26%, ophthalmologists: 26%) demonstrated similarly strong knowledge of tear film assessment. Ninety percent of respondents ranked patient symptoms and meibomian gland evaluation as the most valuable and common diagnostic approaches. Conversely, standardised grading scales and validated dry eye questionnaires were infrequently adopted. Both professions tailored dry eye management according to severity, indicating eyelid hygiene and non-preserved lubricants as mainstay therapies. Ophthalmologists prescribed systemic tetracyclines significantly more often than optometrists for moderate (48% vs 11%) and severe (72% vs 32%) dry eye (p < 0.05). Continuing education conferences were acknowledged as the primary information source used to guide dry eye management practices by both professions. Consistent with evidence-based guidelines, New Zealand eye care professionals combine subjective and objective techniques to diagnose and stratify dry eye management according to disease severity. There is potential to improve dissemination of research evidence into clinical practice, with continuing education via professional conferences the favoured mode of delivery. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  15. Evaluation of Visual Field Test Parameters after Artificial Tear Administration in Patients with Glaucoma and Dry Eye.

    PubMed

    Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin

    2018-01-01

    To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.

  16. Eye-movements and ongoing task processing.

    PubMed

    Burke, David T; Meleger, Alec; Schneider, Jeffrey C; Snyder, Jim; Dorvlo, Atsu S S; Al-Adawi, Samir

    2003-06-01

    This study tests the relation between eye-movements and thought processing. Subjects were given specific modality tasks (visual, gustatory, kinesthetic) and assessed on whether they responded with distinct eye-movements. Some subjects' eye-movements reflected ongoing thought processing. Instead of a universal pattern, as suggested by the neurolinguistic programming hypothesis, this study yielded subject-specific idiosyncratic eye-movements across all modalities. Included is a discussion of the neurolinguistic programming hypothesis regarding eye-movements and its implications for the eye-movement desensitization and reprocessing theory.

  17. Kinematics of Visually-Guided Eye Movements

    PubMed Central

    Hess, Bernhard J. M.; Thomassen, Jakob S.

    2014-01-01

    One of the hallmarks of an eye movement that follows Listing’s law is the half-angle rule that says that the angular velocity of the eye tilts by half the angle of eccentricity of the line of sight relative to primary eye position. Since all visually-guided eye movements in the regime of far viewing follow Listing’s law (with the head still and upright), the question about its origin is of considerable importance. Here, we provide theoretical and experimental evidence that Listing’s law results from a unique motor strategy that allows minimizing ocular torsion while smoothly tracking objects of interest along any path in visual space. The strategy consists in compounding conventional ocular rotations in meridian planes, that is in horizontal, vertical and oblique directions (which are all torsion-free) with small linear displacements of the eye in the frontal plane. Such compound rotation-displacements of the eye can explain the kinematic paradox that the fixation point may rotate in one plane while the eye rotates in other planes. Its unique signature is the half-angle law in the position domain, which means that the rotation plane of the eye tilts by half-the angle of gaze eccentricity. We show that this law does not readily generalize to the velocity domain of visually-guided eye movements because the angular eye velocity is the sum of two terms, one associated with rotations in meridian planes and one associated with displacements of the eye in the frontal plane. While the first term does not depend on eye position the second term does depend on eye position. We show that compounded rotation - displacements perfectly predict the average smooth kinematics of the eye during steady- state pursuit in both the position and velocity domain. PMID:24751602

  18. Immune Privilege and Eye-Derived T-Regulatory Cells.

    PubMed

    Keino, Hiroshi; Horie, Shintaro; Sugita, Sunao

    2018-01-01

    Certain cellular components of the eye, such as neural retina, are unable to regenerate and replicate after destructive inflammation. Ocular immune privilege provides the eye with immune protection against intraocular inflammation in order to minimize the risk to vision integrity. The eye and immune system use strategies to maintain the ocular immune privilege by regulating the innate and adaptive immune response, which includes immunological ignorance, peripheral tolerance to eye-derived antigens, and intraocular immunosuppressive microenvironment. In this review, we summarize current knowledge regarding the molecular mechanism responsible for the development and maintenance of ocular immune privilege via regulatory T cells (Tregs), which are generated by the anterior chamber-associated immune deviation (ACAID), and ocular resident cells including corneal endothelial (CE) cells, ocular pigment epithelial (PE) cells, and aqueous humor. Furthermore, we examined the therapeutic potential of Tregs generated by RPE cells that express transforming growth factor beta (TGF- β ), cytotoxic T lymphocyte-associated antigen-2 alpha (CTLA-2 α ), and retinoic acid for autoimmune uveoretinitis and evaluated a new strategy using human RPE-induced Tregs for clinical application in inflammatory ocular disease. We believe that a better understanding of the ocular immune privilege associated with Tregs might offer a new approach with regard to therapeutic interventions for ocular autoimmunity.

  19. Effect of Oral Lactoferrin on Cataract Surgery Induced Dry Eye: A Randomised Controlled Trial.

    PubMed

    Devendra, Jaya; Singh, Sneha

    2015-10-01

    Cataract surgery is one of the most frequently performed intra-ocular surgeries, of these manual Small Incision Cataract Surgery (SICS) is a time tested technique of cataract removal. Any corneal incisional surgery, including cataract surgery, can induce dry eye postoperatively. Various factors have been implicated, of which oneis the inflammation induced by the surgery. Lactoferrin, a glycoprotein present in tears is said to have anti-inflammatory effects, and promotes cell growth. It has been used orally in patients of immune mediated dry eye to alleviate symptoms. This study was aimed to evaluate the dry eyes induced by manual Small Incision Cataract Surgery, and the effect if any, of oral lactoferrin on the dry eyes. A single centre, prospective randomised controlled trial with a concurrent parallel design. The study was carried out on patients presenting in the OPD of Rohilkhand Medical College hospital for cataract surgery. Sixty four patients of cataract surgery were included in the study. Patients with pre-existing dry eyes, ocular disease or systemic disease predisposing to dry eyes were excluded from the study. The selected patients were assigned into two groups by simple randomisation-Control Group A-32 patients that did not receive oral lactoferrin postoperatively. Group B-32 patients that received oral lactoferrin 350 gm postoperatively from day 1 after SICS. All patients were operated for cataract and their pre and postoperative (on days 7, 14, 30 and 60) dry eye status was assessed using the mean tear film break-up time (tBUT) and Schirmer test 1 (ST 1) as the evaluating parameters. Subjective evaluation of dry eye was done using Ocular Surface Disease Index (OSDI) scoring. Data was analysed for 58 patients, as 6 did not complete the follow up. Unpaired t-test was used to calculate the p-values. There was a statistically significant difference between the tBUT values of the Control and Lactoferrin group from day 14 onwards. The tBUT of control group

  20. Do We Really Need to Wear Proper Eye Protection When Using Holmium:YAG Laser During Endourologic Procedures? Results from an Ex Vivo Animal Model on Pig Eyes.

    PubMed

    Villa, Luca; Cloutier, Jonathan; Compérat, Eva; Kronemberg, Peter; Charlotte, Frederic; Berthe, Laurent; Rouchausse, Yann; Salonia, Andrea; Montorsi, Francesco; Traxer, Olivier

    2016-03-01

    We sought to evaluate the effect of holmium:yttrium-aluminum-garnet (Ho:YAG) laser exposure on ex vivo pig eyes and to test the protective action of different glasses in preventing eye lesions in case of accident. We pointed the tip of a Ho:YAG laser fiber from different distances (0, 3, 5, 8, 10, and 20 cm, respectively) toward the center of the pupil of the pig eye. The Ho:YAG laser was activated for 1 or 5 seconds at three different settings (0.5 J-20 Hz, 1 J-10 Hz, and 2 J-10 Hz, respectively). The experiment was repeated using laser safety glasses and eyeglasses. A total of 78 pig eyes were used. The effects of the Ho:YAG laser on pig eyes were assessed by histopathology. Comparable laser emission experiments were performed on thermal paper at different distances using different pulse energies. Ho:YAG laser-induced corneal lesions were observed in unprotected eyes, ranging from superficial burning lesions to full-thickness necrotic areas, and were directly related to pulse energy and time of exposure and inversely related to the distance from the eye. When the laser was placed 5 cm or more, no corneal damage was observed regardless of the laser setting and the time of exposure. Similar distance/energy level relationships were observed on thermal paper. No damage was observed to the lens or the retina in any of the Ho-YAG laser-treated eyes or in any of the eyes protected by laser safety and eyeglasses. Ho:YAG lasers can cause damage when set to high energy, but only to the cornea, from close distances (0-5 cm) and in the absence of eye protection. Eyeglasses are equally effective in preventing laser damage as laser safety glasses.

  1. The Eyes Are the Windows to the Mind: Direct Eye Gaze Triggers the Ascription of Others' Minds.

    PubMed

    Khalid, Saara; Deska, Jason C; Hugenberg, Kurt

    2016-12-01

    Eye gaze is a potent source of social information with direct eye gaze signaling the desire to approach and averted eye gaze signaling avoidance. In the current work, we proposed that eye gaze signals whether or not to impute minds into others. Across four studies, we manipulated targets' eye gaze (i.e., direct vs. averted eye gaze) and measured explicit mind ascriptions (Study 1a, Study 1b, and Study 2) and beliefs about the likelihood of targets having mind (Study 3). In all four studies, we find novel evidence that the ascription of sophisticated humanlike minds to others is signaled by the display of direct eye gaze relative to averted eye gaze. Moreover, we provide evidence suggesting that this differential mentalization is due, at least in part, to beliefs that direct gaze targets are more likely to instigate social interaction. In short, eye contact triggers mind perception. © 2016 by the Society for Personality and Social Psychology, Inc.

  2. Pink Eye (Conjunctivitis)

    MedlinePlus

    ... way to prevent spreading pink eye is to stay home — or keep your child at home — until eye ... re not able to take time off — just stay consistent in practicing good ... present in the mother's birth canal. These bacteria cause no symptoms in ...

  3. Understanding pink eye

    USDA-ARS?s Scientific Manuscript database

    Pink eye (PE) is a physiological tuber disorder that can result in serious processing complications and storage losses. The earliest external symptoms consist of an ephemeral pinkish discoloration around tuber eyes, predominately at the bud end of the tuber. These pinkish areas can then develop into...

  4. Effect of school eye health promotion on children's eye health literacy in Vietnam.

    PubMed

    Paudel, Prakash; Yen, Phung Thi; Kovai, Vilas; Naduvilath, Thomas; Ho, Suit May; Giap, Nguyen Viet; Holden, Brien A

    2017-10-06

    Health promotion intervention in schools is a useful strategy to improve students' health awareness. The purpose of this study was to assess the effect of eye health promotion interventions on eye health literacy in school children in Vietnam. A piloted questionnaire was administered to 300 children from five secondary schools in Ba Ria-Vung Tau, Vietnam at baseline and re-administered after the eye health promotion interventions. McNemar chi-square and logistic regression were used for statistical analysis. A total of 300 children aged 12-15 years (mean, 13.3 ± 1.3 years; 60% female) participated in the baseline survey. The participation rate in the post-health promotion survey was 94.7%. After the health promotion interventions, number of children who had correct eye health knowledge increased by 10-20% (60-75% to 70-95%), more children reported having had an eye examination (63.3% to 84.7%; p < 0.001) and more reported wearing spectacles (36.1% to 43.4%; p = 0.04). Children in urban schools were twice as likely to have improved knowledge of vision loss compared with children in rural schools (odds ratio, 2.1-4.1; p = 0.01 to p < 0.001). Children from rural schools had significantly higher odds of visiting doctor after the eye problems worsened (odds ratio, 4.5; p < 0.001). These results imply that eye health promotion interventions significantly improve eye health knowledge, attitudes and practices of school children. Additionally, participation of parents and teachers as change agents may further improve children's health literacy. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Diclofenac sodium delivery to the eye: in vitro evaluation of novel solid lipid nanoparticle formulation using human cornea construct.

    PubMed

    Attama, Anthony A; Reichl, Stephan; Müller-Goymann, Christel C

    2008-05-01

    Solid lipid nanoparticles (SLNs) were prepared with a combination of homolipid from goat (goat fat) and phospholipid, and evaluated for diclofenac sodium (DNa) delivery to the eye using bio-engineered human cornea, produced from immortalized human corneal endothelial cells (HENC), stromal fibroblasts and epithelial cells CEPI 17 CL 4. Encapsulation efficiency was high and sustained release of DNa and high permeation through the bio-engineered cornea were achieved. Results obtained in this work showed that permeation of DNa through the cornea construct was improved by formulation as SLN modified with phospholipid.

  6. Effect of H-7 on secondary cataract after phacoemulsification in the live rabbit eye.

    PubMed

    Tian, Baohe; Heatley, Gregg A; Filla, Mark S; Kaufman, Paul L

    2010-12-01

    This study is aimed to determine if the serine-threonine kinase inhibitor H-7 inhibits secondary cataract after phacoemulsification in the live rabbit eye. Eighteen rabbits underwent extracapsular lens extraction by phacoemulsification in 1 eye. The eye was treated with intravitreal H-7 (300 or 1,200 μM; n = 6 or 5) or balanced salt solution (BSS) (n = 7) immediately after the surgery and twice weekly for 10 weeks. Each eye received slit lamp biomicroscopy once a week, during which posterior capsule opacification (PCO) was evaluated. The eye was then enucleated and the lens capsule was prepared, fixed, and imaged. PCO was evaluated again on the isolated lens capsule under a phase microscope. Soemmering's ring area (SRA) and the entire lens capsule area were measured from capsule images on a computer and the percentage of SRA (PSRA) in the entire capsule area was calculated. Wet weight of the capsule (WW) was determined on a balance. No significant difference in PCO was observed in any comparison. No significant differences in SRA, PSRA, and WW were observed between the 300 μM H-7-treated eye and the BSS-treated eye. However, SRA, PSRA, and WW in the 1,200 μM H-7-treated eye were significantly smaller than those in the BSS-treated eye [28.3 ± 16.2 vs. 61.4 ± 8.86 mm(2) (P = 0.001), 33% ± 20% vs. 65% ± 15% (P = 0.01), and 65.6 ± 27.9 vs. 127.0 ±37.3 mg (P = 0.01)]. Intravitreal H-7 (1,200 μM) significantly inhibits Soemmering's ring formation in the live rabbit eye, suggesting that agents that inhibit the actomyosin system in cells may prevent secondary cataract after phacoemulsification.

  7. HUMAN EYE OPTICS: Determination of positions of optical elements of the human eye

    NASA Astrophysics Data System (ADS)

    Galetskii, S. O.; Cherezova, T. Yu

    2009-02-01

    An original method for noninvasive determining the positions of elements of intraocular optics is proposed. The analytic dependence of the measurement error on the optical-scheme parameters and the restriction in distance from the element being measured are determined within the framework of the method proposed. It is shown that the method can be efficiently used for determining the position of elements in the classical Gullstrand eye model and personalised eye models. The positions of six optical surfaces of the Gullstrand eye model and four optical surfaces of the personalised eye model can be determined with an error of less than 0.25 mm.

  8. The Effect of Topical Diquafosol Tetrasodium 3% on Dry Eye After Cataract Surgery.

    PubMed

    Baek, Jiwon; Doh, Sang Hee; Chung, Sung Kun

    2016-10-01

    To evaluate the effectiveness of 3% diquafosol tetrasodium for treating dry eye after cataract surgery. Among patients who underwent bilateral cataract surgery, 34, who met the diagnostic criteria for dry eye syndrome 1 week postoperatively, were enrolled. Patients were randomly assigned to receive 3.0% diquafosol tetrasodium ophthalmic solution in one eye and 0.9% saline in the other eye four times daily for 8 weeks. Dry eye severity was measured at 1, 5, and 9 postoperative weeks using the Schirmer 1 test (SIT), tear film breakup time (TBUT), and fluorescein corneal staining. tear meniscus height (TMH), tear meniscus depth (TMD), and tear meniscus area (TMA) measured using Fourier-domain optical coherence tomography and symptom questionnaire scores. TBUT and corneal staining significantly improved 8 weeks postoperatively in eyes treated with 3.0% diquafosol tetrasodium (p < 0.01, p < 0.01) and were better than normal saline-treated eyes (p < 0.01, p < 0.01). SIT did not improve (p = 0.26). TMH, TMD, and TMA did not improve at 4 and 8 weeks. All symptom questionnaire scores improved in eyes treated with 3.0% diquafosol tetrasodium (all p < 0.01). The 3.0% diquafosol tetrasodium treatment improved tear film stability and subjective symptoms of dry eye after cataract surgery. Increased mucin production as a result of diquafosol treatment may have caused these results.

  9. How the Human Eye Focuses.

    ERIC Educational Resources Information Center

    Koretz, Jane F.; Handelman, George H.

    1988-01-01

    Describes the decline in people's ability to focus their eyes as their age increases. Discusses probable causes of this effect including changes in the eye's geometry and biochemistry. Diagrammatically illustrates age related changes in the lens of the human eye. (CW)

  10. Low bandwidth eye tracker for scanning laser ophthalmoscopy

    NASA Astrophysics Data System (ADS)

    Harvey, Zachary G.; Dubra, Alfredo; Cahill, Nathan D.; Lopez Alarcon, Sonia

    2012-02-01

    The incorporation of adaptive optics to scanning ophthalmoscopes (AOSOs) has allowed for in vivo, noninvasive imaging of the human rod and cone photoreceptor mosaics. Light safety restrictions and power limitations of the current low-coherence light sources available for imaging result in each individual raw image having a low signal to noise ratio (SNR). To date, the only approach used to increase the SNR has been to collect large number of raw images (N >50), to register them to remove the distortions due to involuntary eye motion, and then to average them. The large amplitude of involuntary eye motion with respect to the AOSO field of view (FOV) dictates that an even larger number of images need to be collected at each retinal location to ensure adequate SNR over the feature of interest. Compensating for eye motion during image acquisition to keep the feature of interest within the FOV could reduce the number of raw frames required per retinal feature, therefore significantly reduce the imaging time, storage requirements, post-processing times and, more importantly, subject's exposure to light. In this paper, we present a particular implementation of an AOSO, termed the adaptive optics scanning light ophthalmoscope (AOSLO) equipped with a simple eye tracking system capable of compensating for eye drift by estimating the eye motion from the raw frames and by using a tip-tilt mirror to compensate for it in a closed-loop. Multiple control strategies were evaluated to minimize the image distortion introduced by the tracker itself. Also, linear, quadratic and Kalman filter motion prediction algorithms were implemented and tested and tested using both simulated motion (sinusoidal motion with varying frequencies) and human subjects. The residual displacement of the retinal features was used to compare the performance of the different correction strategies and prediction methods.

  11. Hemodynamic response to intravitreal triamcinolone in eyes with macular edema: intravitreal triamcinolone and ocular blood flow.

    PubMed

    Cekiç, Osman; Bardak, Yavuz; Tiğ, Sahin U; Demirkol, Aykut; Ekim, Mustafa M; Altintaş, Onem; Yeşildağ, Ahmet; Oyar, Orhan

    2007-10-01

    To assess ocular hemodynamic response to intravitreal triamcinolone in patients with macular edema due to diabetes or retinal vein occlusion. Forty-three patients that were injected by intravitreal triamcinolone acetonide (0.1 cc 4 mg) for unilateral macular edema due to diabetes mellitus (n = 17) and occlusion of retinal vein (n = 26) underwent ocular hemodynamic evaluation by color Doppler imaging (CDI) before and one, two and three months after injection. Non-injected fellow eyes as well as 16 healthy volunteers were also evaluated. In patients with diabetic macular edema, there was no hemodynamic difference between eyes to be injected and non-injected at baseline (P > 0.23). Compared to controls, a significant difference existed in the ophthalmic artery resistant index (P = 0.001) and end-diastolic velocity (P < 0.001) in diabetics. At one month, compared to fellow eyes, change in end diastolic velocity from baseline in treated eyes was significantly decreased in posterior ciliary arteries (0.68 +/- 0.34 cm/s [mean +/- SEM] vs. -1.04 +/- 0.81 cm/s, P = 0.012). Throughout the study period, no significant alteration from baseline in the resistant index of any artery was noted in treated diabetic eyes (P > 0.05). In eyes with retinal vein occlusion, baseline CDI evaluation demonstrated reduced posterior ciliary arteries systolic flow velocity compared to fellow and control eyes (13.24 +/- 1.04 cm/s, 16.37 +/- 0.76 cm/s and 14.33 +/- 1.41 cm/s, respectively, P = 0.007). Increased peak systolic velocity in the posterior ciliary arteries at one week (P = 0.02), one month (P = 0.005) and two months (P = 0.04), and increase in central retinal artery resistant index at one month was noted (P = 0.05). Intravitreal triamcinolone temporarily changed central retinal artery blood flow and posterior ciliary arteries' peak systolic blood velocity in eyes with retinal vein occlusion whilst no response of blood flow to triamcinolone injection but only transiently altered end

  12. Incidence of Fellow Eye Involvement in Patients With Unilateral Exudative Age-Related Macular Degeneration.

    PubMed

    Yanagi, Yasuo; Mohla, Aditi; Lee, Shu Yen; Mathur, Ranjana; Chan, Choi Mun; Yeo, Ian; Wong, Tien Yin; Cheung, Chui Ming Gemmy

    2018-06-07

    Since the advent of optical coherence tomography angiography (OCT-A), nonexudative neovascularization has been described in the fellow eyes of unilateral exudative age-related macular degeneration (AMD). However, there is limited literature describing the natural course and optimal management of these lesions. To determine the incidence of fellow eye involvement in patients presenting with unilateral typical AMD or polypoidal choroidal vasculopathy and to evaluate the patterns of OCT-A changes within 6 months before the onset of exudative changes, especially focusing on nonexudative neovascularization. Data for this study were taken from a prospective, observational cohort study involving Asian patients with exudative AMD in the Asian AMD Phenotyping Study between October 2015 and March 2016. Analyses began in June 2017. Only patients who had gradable OCT-A and indocyanine green angiography (ICGA) scans of the fellow eye at baseline and follow-up at least 6 months apart were included for the analysis. The contralateral eye was evaluated for presence of nonexudative neovascularization based on multimodal imaging, which included ICGA, spectral domain optical coherence tomography, and OCT-A. The difference between the incidence of those with nonexudative choroidal neovascularization and those without as analyzed using log-rank test and qualitative analysis of OCT-A images. We included 95 fellow eyes of 95 patients who presented with unilateral exudative AMD with a mean (SD) age of 68.6 (8.6) years. Nonexudative neovascularization was present in 18 eyes (19%) (8 [22.9%] and 10 [19.0%] fellow eyes with typical AMD and polypoidal choroidal vasculopathy, respectively; 8 [44.4%] on OCT-A; 5 [27.8%] on ICGA; and 5 [27.8%] on both OCT-A and ICGA). Development of exudative changes was noted in 6 fellow eyes (6.3%). Four eyes developed exudation from previously noted nonexudative neovascularization, and 2 eyes arose exudative changes from de novo. The probability of developing

  13. Antioxidants intake and dry eye syndrome: a crossover, placebo-controlled, randomized trial.

    PubMed

    Drouault-Holowacz, Sophie; Bieuvelet, Séverine; Burckel, André; Rigal, Danièle; Dubray, Claude; Lichon, Jean-Louis; Bringer, Paul; Pilon, Francois; Chiambaretta, Frédéric

    2009-01-01

    To assess whether an orally administered antioxidant dietary supplement could improve the objective clinical signs and alleviate the subjective symptoms of dry eye syndrome. Twenty-four subjects diagnosed with dry eye syndrome were randomized in a crossover, double-blind, controlled, randomized study to receive a placebo or an antioxidants combination (Oxybiane) for 12 weeks. In all subjects, break-up time (BUT) test, Schirmer test, ocular symptoms (sore eyes, burning, itching, sensation of foreign object in the eye, photophobia, sticky eyes, and redness), visual comfort, and general well-being were evaluated weekly. After 12 weeks of supplementation with Oxybiane, both the BUT scores (27.3%+/-8.4% with Oxybiane versus 3.61%+/-4.3% with the placebo, p=0.017) and the Schirmer scores (26.9%+/-14.2% with Oxybiane versus -4.7%+/-3.4% with the placebo, p=0.037) were significantly increased. A significantly improvement was also observed considering subjective clinical symptoms such as burning (p=0.031), itching (p=0.027), sensation of foreign body in eye (p=0.030), and redness (p=0.043). CONCLUSIONS. Supplementation with oral antioxidants can improve both tear stability and quantity but also subjective clinical signs.

  14. On Biometrics With Eye Movements.

    PubMed

    Zhang, Youming; Juhola, Martti

    2017-09-01

    Eye movements are a relatively novel data source for biometric identification. When video cameras applied to eye tracking become smaller and more efficient, this data source could offer interesting opportunities for the development of eye movement biometrics. In this paper, we study primarily biometric identification as seen as a classification task of multiple classes, and secondarily biometric verification considered as binary classification. Our research is based on the saccadic eye movement signal measurements from 109 young subjects. In order to test the data measured, we use a procedure of biometric identification according to the one-versus-one (subject) principle. In a development from our previous research, which also involved biometric verification based on saccadic eye movements, we now apply another eye movement tracker device with a higher sampling frequency of 250 Hz. The results obtained are good, with correct identification rates at 80-90% at their best.

  15. Irreversible Electroporation of Human Primary Uveal Melanoma in Enucleated Eyes

    PubMed Central

    Mandel, Yossi; Laufer, Shlomi; Belkin, Michael; Rubinsky, Boris; Pe'er, Jacob; Frenkel, Shahar

    2013-01-01

    Uveal melanoma (UM) is the most common primary intraocular tumor in adults and is characterized by high rates of metastatic disease. Although brachytherapy is the most common globe-sparing treatment option for small- and medium-sized tumors, the treatment is associated with severe adverse reactions and does not lead to increased survival rates as compared to enucleation. The use of irreversible electroporation (IRE) for tumor ablation has potential advantages in the treatment of tumors in complex organs such as the eye. Following previous theoretical work, herein we evaluate the use of IRE for uveal tumor ablation in human ex vivo eye model. Enucleated eyes of patients with uveal melanoma were treated with short electric pulses (50–100 µs, 1000–2000 V/cm) using a customized electrode design. Tumor bioimpedance was measured before and after treatment and was followed by histopathological evaluation. We found that IRE caused tumor ablation characterized by cell membrane disruption while sparing the non-cellular sclera. Membrane disruption and loss of cellular capacitance were also associated with significant reduction in total tumor impedance and loss of impedance frequency dependence. The effect was more pronounced near the pulsing electrodes and was dependent on time from treatment to fixation. Future studies should further evaluate the potential of IRE as an alternative method of uveal melanoma treatment. PMID:24039721

  16. Femtosecond Laser in situ Keratomileusis Flap Creation in Narrow Palpebral Fissure Eyes without Suction

    PubMed Central

    Chang, John S.M.; Law, Antony K.P.; Ng, Jack C.M.; Cheng, May S.Y.

    2017-01-01

    Purpose To evaluate a surgical technique used in eyes with narrow palpebral fissure undergoing femtosecond laser flap creation without suction during laser in situ keratomileusis (LASIK). Methods All data of 2 patient groups were collected through chart review. Group 1 consisted of 6 eyes with narrow palpebral fissure in which the suction ring was manually fixated and femtosecond laser was applied accordingly. Thirty comparison cases were randomly drawn from among eyes that underwent a standard LASIK procedure matched for age and preoperative refraction (group 2). Only 1 eye of each patient was selected to compare the refractive and visual outcomes between groups. Results In all group 1 eyes, the flaps were created successfully with manual fixation of the suction ring without suction. No eyes lost 2 or more lines of vision. No significant difference was found in the safety and refractive outcomes between groups. Conclusion Manual fixation of the suction ring in eyes with narrow palpebral fissure without suction was feasible for flap creation during LASIK. PMID:28690535

  17. Reading strategies in mild to moderate strabismic amblyopia: an eye movement investigation.

    PubMed

    Kanonidou, Evgenia; Proudlock, Frank A; Gottlob, Irene

    2010-07-01

    PURPOSE. To investigate oculomotor strategies in strabismic amblyopia and evaluate abnormalities during monocular and binocular reading. METHODS. Eye movements were recorded with a head-mounted infrared video eye-tracker (250 Hz, <0.01 degrees resolution) in 20 strabismic amblyopes (mean age, 44.9 +/- 10.7 years) and 20 normal control subjects (mean age, 42.8 +/- 10.9 years) while they silently read paragraphs of text. Monocular reading comparisons were made between the amblyopic eye and the nondominant eye of control subjects and the nonamblyopic eye and the dominant eye of the control subjects. Binocular reading between the amblyopic and control subjects was also compared. RESULTS. Mean reading speed, number of progressive and regressive saccades per line, saccadic amplitude (of progressive saccades), and fixation duration were estimated. Inter- and intrasubject statistical comparisons were made. Reading speed was significantly slower in amblyopes than in control subjects during monocular reading with amblyopic (13.094 characters/s vs. 22.188 characters/s; P < 0.0001) and nonamblyopic eyes (16.241 characters/s vs. 22.349 characters/s, P < 0.0001), and binocularly (15.698 characters/s vs. 23.425 characters/s, P < 0.0001). In amblyopes, reading was significantly slower with the amblyopic eye than with the nonamblyopic eye in binocular viewing (P < 0.05). These differences were associated with significantly more regressive saccades and longer fixation durations, but not with changes in saccadic amplitudes. CONCLUSIONS. In strabismic amblyopia, reading is impaired, not only during monocular viewing with the amblyopic eye, but also with the nonamblyopic eye and binocularly, even though normal visual acuity pertains to the latter two conditions. The impaired reading performance is associated with differences in both the saccadic and fixational patterns, most likely as adaptation strategies to abnormal sensory experiences such as crowding and suppression.

  18. Cyclooxygenase-2 expression in the eyes of cats with and without uveitis.

    PubMed

    Sim, Zhi Hui; Pinard, Chantale L; Plattner, Brandon L; Bienzle, Dorothee

    2018-01-01

    OBJECTIVE To characterize the distribution and intensity of cyclooxygenase (COX)-2 expression in the eyes of cats with and without uveitis and to determine whether COX-2 expression is correlated with severity of inflammation. SAMPLES Archived ocular tissue specimens from 51 cats with and 10 cats without ocular disease. PROCEDURES Specimens from only 1 eye were evaluated for each cat. Specimens were stained with H&E stain or immunohistochemical stain for detection of COX-2 and reviewed. For each eye, the type, severity, and distribution of inflammation and the distribution and intensity of COX-2 expression were determined for the uvea and other ocular tissues. Correlation between COX-2 expression and inflammation severity was also assessed. RESULTS COX-2 was not expressed in any nondiseased eye. Of the 51 diseased eyes, 20 had histologic evidence of lymphocytic-plasmacytic uveitis, 13 had neutrophilic uveitis, 11 had diffuse iris melanoma with uveitis, and 7 had diffuse iris melanoma without uveitis. Of the 44 eyes with uveitis, COX-2 was detected in the uvea of 16, including 11 eyes with lymphocytic-plasmacytic uveitis, 4 with neutrophilic uveitis, and 1 with diffuse iris melanoma-induced uveitis. Inflammation was severe, moderate, or mild in 10, 5, and 1 of those eyes, respectively. Cyclooxygenase-2 was detected in the cornea of 21 eyes with uveitis and 1 eye with diffuse iris melanoma without uveitis. Uveitis severity was positively correlated with COX-2 expression in both the uvea and cornea. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that COX-2 is an inflammatory mediator in feline uveitis but not diffuse iris melanoma.

  19. LIMNOLOGICAL OPTOMETRY: EXAMINING EARTH'S EYE

    EPA Science Inventory

    In Thoreau's Walden, a lake is described as the landscape's most expressive feature and the earth's eye. Collectively, scientists are charged by society to assess, monitor, and remedy maladies of earth's eye in the same way optometrists maintain the health of the human eye. This ...

  20. Simulation of wave propagation inside a human eye: acoustic eye model (AEM)

    NASA Astrophysics Data System (ADS)

    Požar, T.; Halilovič, M.; Horvat, D.; Petkovšek, R.

    2018-02-01

    The design and development of the acoustic eye model (AEM) is reported. The model consists of a computer-based simulation that describes the propagation of mechanical disturbance inside a simplified model of a human eye. The capabilities of the model are illustrated with examples, using different laser-induced initial loading conditions in different geometrical configurations typically occurring in ophthalmic medical procedures. The potential of the AEM is to predict the mechanical response of the treated eye tissue in advance, thus complementing other preliminary procedures preceding medical treatments.