Sample records for saltstone headspace summary

  1. Results and analysis of saltstone cores taken from saltstone disposal unit cell 2A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reigel, M. M.; Hill, K. A.

    2016-03-01

    As part of an ongoing Performance Assessment (PA) Maintenance Plan, Savannah River Remediation (SRR) has developed a sampling and analyses strategy to facilitate the comparison of field-emplaced samples (i.e., saltstone placed and cured in a Saltstone Disposal Unit (SDU)) with samples prepared and cured in the laboratory. The primary objectives of the Sampling and Analyses Plan (SAP) are; (1) to demonstrate a correlation between the measured properties of laboratory-prepared, simulant samples (termed Sample Set 3), and the field-emplaced saltstone samples (termed Sample Set 9), and (2) to validate property values assumed for the Saltstone Disposal Facility (SDF) PA modeling. Themore » analysis and property data for Sample Set 9 (i.e. six core samples extracted from SDU Cell 2A (SDU2A)) are documented in this report, and where applicable, the results are compared to the results for Sample Set 3. Relevant properties to demonstrate the aforementioned objectives include bulk density, porosity, saturated hydraulic conductivity (SHC), and radionuclide leaching behavior.« less

  2. MEASUREMENT OF WASTE LOADING IN SALTSTONE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harbour, J; Vickie Williams, V

    2008-07-18

    One of the goals of the Saltstone variability study is to identify the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. One of those properties of importance is the Waste Loading (WL) of the decontaminated salt solution (DSS) in the Saltstone waste form. Waste loading is a measure of the amount of waste that can be incorporated within a waste form. The value of the Saltstone waste loading ultimately determines the number of vaults that will be required to disposition all of the DSS. In this report, the waste loadingmore » is defined as the volume in milliliters of DSS per liter of Saltstone waste form. The two most important parameters that determine waste loading for Saltstone are water to cementitious material (w/cm) ratio and the cured grout density. Data are provided that show the dependence of waste loading on the w/cm ratio for a fixed DSS composition using the current premix material (45% Blast Furnace Slag (BFS), 45% Fly Ash (FA) and 10% Ordinary Portland Cement (OPC)). The impact of cured grout density on waste loading was also demonstrated. Mixes (at 0.60 w/cm) made with a Modular Caustic side extraction Unit (MCU) simulant and either OPC or BFS have higher cured grout densities than mixes made with premix and increase the WL to 709 mL/L for the OPC mix and 689 mL/L for the BFS mix versus the value of 653 mL/L for MCU in premix at 0.60 w/cm ratio. Bleed liquid reduces the waste loading and lowers the effective w/cm ratio of Saltstone. A method is presented (and will be used in future tasks) for correcting the waste loading and the w/cm ratio of the as-batched mixes in those cases where bleed liquid is present. For example, the Deliquification, Dissolution and Adjustment (DDA) mix at an as-batched 0.60 w/cm ratio, when corrected for % bleed, gives a mix with a 0.55 w/cm ratio and a WL that has been reduced from 662 to 625 mL/L. An example is provided that

  3. 1QCY17 Saltstone waste characterization analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, F. C.

    2017-07-25

    In the first quarter of calendar year 2017, a salt solution sample was collected from Tank 50 on January 16, 2017 in order to meet South Carolina (SC) Regulation 61-107.19 Part I C, “Solid Waste Management: Solid Waste Landfills and Structural Fill – General Requirements” and the Saltstone Disposal Facility Class 3 Landfill Permit. The Savannah River National Laboratory (SRNL) was requested to prepare and ship saltstone samples to a United States Environmental Protection Agency (EPA) certified laboratory to perform the Toxicity Characteristic Leaching Procedure (TCLP) and subsequent characterization.

  4. Impact Of Standing Water On Saltstone Placement II - Hydraulic Conductivity Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cozzi, A. D.; Pickenheim, B. R.

    2012-12-06

    The amount of water present during placement and subsequent curing of saltstone has the potential to impact several properties important for grout quality. An active drain water system can remove residual standing water and expose the surface of the placed saltstone to air. Oxidation of the saltstone may result in an increase in the leachability of redox sensitive elements. A dry surface can lead to cracking, causing an increase in hydraulic conductivity. An inactive drain water system can allow standing water that generates unnecessary hydrostatic head on the vault walls. Standing water that cannot be removed via the drain systemmore » will be available for potential incorporation into subsequent grout placements. The objective of this work is to study the impact of standing water on grout quality pertaining to disposal units. A series of saltstone mixes was prepared and cured at ambient temperature to evaluate the impact of standing water on saltstone placement. The samples were managed to control drying effects on leachability by either exposing or capping the samples. The water to premix ratio was varied to represent a range of processing conditions. Samples were analyzed for density, leachability, and hydraulic conductivity. Report SRNL-STI-2012-00546 was issued detailing the experimental procedure, results, and conclusions related to density and leachability. In the previous report, it was concluded that: density tends to increase toward the bottom of the samples. This effect is pronounced with excess bleed water; drying of the saltstone during curing leads to decreased Leachability Index (more leaching) for potassium, sodium, rhenium, nitrite, and nitrate; there is no noticeable effect on saltstone oxidation/leachability by changing the water to premix ratio (over the range studied), or by pouring into standing water (when tested up to 10 volume percent). The hydraulic conductivity data presented in this report show that samples cured exposed to the

  5. 78 FR 57668 - U.S. Nuclear Regulatory Commission Planned for Monitoring Activities for the Saltstone Disposal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-19

    ... Monitoring Activities for the Saltstone Disposal Facility at the Savannah River Site, Revision 1 AGENCY... responsibilities for monitoring DOE's waste disposal activities at the Saltstone Disposal Facility (SDF) at the... Monitoring Disposal Actions Taken by the U.S. Department of Energy at the Savannah River Site Saltstone...

  6. Verification of Sulfate Attack Penetration Rates for Saltstone Disposal Unit Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G. P.

    Recent Special Analysis modeling of Saltstone Disposal Units consider sulfate attack on concrete and utilize degradation rates estimated from Cementitious Barriers Partnership software simulations. This study provides an independent verification of those simulation results using an alternative analysis method and an independent characterization data source. The sulfate penetration depths estimated herein are similar to the best-estimate values in SRNL-STI-2013-00118 Rev. 2 and well below the nominal values subsequently used to define Saltstone Special Analysis base cases.

  7. Technical Insights for Saltstone PA Maintenance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G.; Sarkar, S.; Mahadevan, S.

    2011-07-20

    The Cementitious Barriers Partnership (CBP) is a collaborative program sponsored by the US DOE Office of Waste Processing. The objective of the CBP is to develop a set of computational tools to improve understanding and prediction of the long-term structural, hydraulic, and chemical performance of cementitious barriers and waste forms used in nuclear applications. CBP tools are expected to better characterize and reduce the uncertainties of current methodologies for assessing cementitious barrier performance and increase the consistency and transparency of the assessment process, as the five-year program progresses. In September 2009, entering its second year of funded effort, the CBPmore » sought opportunities to provide near-term tangible support to DOE Performance Assessments (PAs). The Savannah River Saltstone Disposal Facility (SDF) was selected for the initial PA support effort because (1) cementitious waste forms and barriers play a prominent role in the performance of the facility, (2) certain important long-term behaviors of cementitious materials composing the facility are uncertain, (3) review of the SDF PA by external stakeholders is ongoing, and (4) the DOE contractor responsible for the SDF PA is open to receiving technical assistance from the CBP. A review of the current (SRR Closure & Waste Disposal Authority 2009) and prior Saltstone PAs (e.g., Cook et al. 2005) suggested five potential opportunities for improving predictions. The candidate topics considered were (1) concrete degradation from external sulfate attack, (2) impact of atmospheric exposure to concrete and grout before closure, such as accelerated slag and Tc-99 oxidation, (3) mechanistic prediction of geochemical conditions, (4) concrete degradation from rebar corrosion due to carbonation, and (5) early age cracking from drying and/or thermal shrinkage. The candidate topics were down-selected considering the feasibility of addressing each issue within approximately six months, and

  8. DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almond, P.; Kaplan, D.

    Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd valuesmore » from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen

  9. Solubility Control of Technetium Release from Saltstone by Tc02•xH20

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J.; Williams, Benjamin D.

    2013-11-12

    Saltstone leaching experiments were conducted using a modified single-pass flow-through method under anoxic conditions. The analytical results of leachates collected from these experiments were evaluated using thermodynamic modeling to determine if the data were consistent with potential solubility controlling phases. The results demonstrate that technetium concentrations in water in contact with Saltstone under anoxic conditions is controlled by the solubility of TcO2•xH2O (likely TcO2•1.6H2O). In our system equilibrium solubility appears to have been reached within two weeks at a concentration of approximately 1.5 x 10-6 M. This concentration is likely to vary as the composition of Saltstone pore fluid evolvesmore » over time. As the pH goes from the initial high values (~12.5-13) to lower values, the solubility of technetium will decrease significantly. The thermodynamic data used to determine the solubility of TcO2•1.6H2O were taken from the tabulation of critically selected thermodynamic data determined by the Nuclear Energy Agency. Solid phase characterization to demonstrate the presence of TcO2•xH2O was not possible due to the low concentrations of technetium in our samples. Previous solid phase characterization studies with cementitious waste forms that were very similar to our Saltstone samples as well as reaction products derived from reductive immobilization of TcO4- by amorphous FeS clearly indicate the presence of TcO2 with varying degrees of hydration. Although, the presence of TcSx or other reduced technetium sulfide phases in our samples cannot be ruled out, release of technetium from Saltstone will be controlled by TcO2•1.6H2O because of its higher solubility. Our results clearly demonstrate that the release mechanism of technetium from Saltstone under reducing conditions is solubility controlled by TcO2•xH2O (likely TcO2•1.6H2O); however, distribution coefficients (Kds), that describe sorption and not solubility, were calculated

  10. SALTSTONE VAULT CLASSIFICATION SAMPLES MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT/ACTINIDE REMOVAL PROCESS WASTE STREAM APRIL 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eibling, R.

    Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained by SRNL on April 5, 2011 (Tank 50H sampling occurred on April 4, 2011) during 2QCY11 to determine the non-hazardous nature of the grout and for additional vault classification analyses. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium,more » cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. Additional inorganic species determined by B&W TSG-RACL include aluminum, boron, chloride, cobalt, copper, fluoride, iron, lithium, manganese, molybdenum, nitrate/nitrite as Nitrogen, strontium, sulfate, uranium, and zinc and the following radionuclides: gross alpha, gross beta/gamma, 3H, 60Co, 90Sr, 99Tc, 106Ru, 106Rh, 125Sb, 137Cs, 137mBa, 154Eu, 238Pu, 239/240Pu, 241Pu, 241Am, 242Cm, and 243/244Cm. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the VOCs benzene, toluene, and 1-butanol. GEL also determines phenol (total) and the following radionuclides: 147Pm, 226Ra and 228Ra. Preparation of the 2QCY11 saltstone samples for the quarterly analysis and for vault classification purposes and the subsequent TCLP analyses of these samples showed that: (1) The saltstone waste form disposed of in the Saltstone Disposal Facility in 2QCY11 was not characteristically hazardous for toxicity. (2) The concentrations of the eight RCRA metals and UHCs identified as possible in the saltstone waste form were present at levels below the UTS. (3) Most of the

  11. EVALUATION AND RECOMMENDATION OF SALTSTONE MIXER AUGER/PADDLES MATERIALS OF CONSTRUCTION FOR IMPROVED WEAR RESISTANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mickalonis, J.; Torres, R.

    2012-08-15

    Wear and corrosion testing were conducted to evaluate alternate materials of construction for the Saltstone mixer auger and paddles. These components have been degraded by wear from the slurry processed in the mixer. Material test options included PVD coatings (TiN, TiCN, and ZrN), weld overlays (Stellite 12 and Ultimet) and higher hardness steels and carbides (D2 and tungsten carbide). The corrosion testing demonstrated that the slurry is not detrimental to the current materials of construction or the new candidates. The ASTM G75 Miller wear test showed that the high hardness materials and the Stellite 12 weld overlay provide superior wearmore » relative to the Astralloy and CF8M stainless steel, which are the current materials of construction, as well as the PVD coatings and Ultimet. The following recommendations are made for selecting new material options and improving the overall wear resistance of the Saltstone mixer components: A Stellite 12 weld overlay or higher hardness steel (with toughness equivalent to Astralloy) be used to improve the wear resistance of the Saltstone mixer paddles; other manufacturing specifications for the mixer need to be considered in this selection. The current use of the Stellite 12 weld overlay be evaluated so that coverage of the 316 auger can be optimized for improved wear resistance of the auger. The wear surfaces of the Saltstone mixer auger and paddles be evaluated so that laboratory data can be better correlated to actual service. The 2-inch Saltstone mixer prototype be used to verify material performance.« less

  12. Composite analysis E-area vaults and saltstone disposal facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cook, J.R.

    1997-09-01

    This report documents the Composite Analysis (CA) performed on the two active Savannah River Site (SRS) low-level radioactive waste (LLW) disposal facilities. The facilities are the Z-Area Saltstone Disposal Facility and the E-Area Vaults (EAV) Disposal Facility. The analysis calculated potential releases to the environment from all sources of residual radioactive material expected to remain in the General Separations Area (GSA). The GSA is the central part of SRS and contains all of the waste disposal facilities, chemical separations facilities and associated high-level waste storage facilities as well as numerous other sources of radioactive material. The analysis considered 114 potentialmore » sources of radioactive material containing 115 radionuclides. The results of the CA clearly indicate that continued disposal of low-level waste in the saltstone and EAV facilities, consistent with their respective radiological performance assessments, will have no adverse impact on future members of the public.« less

  13. Method for improving accuracy in full evaporation headspace analysis.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2017-05-01

    We report a new headspace analytical method in which multiple headspace extraction is incorporated with the full evaporation technique. The pressure uncertainty caused by the solid content change in the samples has a great impact to the measurement accuracy in the conventional full evaporation headspace analysis. The results (using ethanol solution as the model sample) showed that the present technique is effective to minimize such a problem. The proposed full evaporation multiple headspace extraction analysis technique is also automated and practical, and which could greatly broaden the applications of the full-evaporation-based headspace analysis. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Tank Vapor Characterization Project: Tank 241-S-102 fourth temporal study: Headspace gas and vapor characterization results from samples collected on December 19, 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pool, K.H.; Evans, J.C.; Olsen, K.B.

    1997-08-01

    This report presents the results from analyses of samples taken from the headspace of waste storage tank 241-S-102 (Tank S-102) at the Hanford Site in Washington State. Tank headspace samples collected by SGN Eurisys Service Corporation (SESC) were analyzed by Pacific Northwest National Laboratory (PNNL) to determine headspace concentrations of selected non-radioactive analytes. Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Vapor concentrations from sorbent trap samples are based on measured sample volumes provided by SESC. Ammonia was determined to be above the immediate notification limit of 150 ppm as specified by the sampling and analysis planmore » (SAP). Hydrogen was the principal flammable constituent of the Tank S-102 headspace, determined to be present at approximately 2.410% of its lower flammability limit (LFL). Total headspace flammability was estimated to be <2.973% of its lower flammability limit (LFL). Total headspace flammability was estimated to be <2.973% of the LFL. Average measured concentrations of targeted gases, inorganic vapors, and selected organic vapors are provided in Table S.1. A summary of experimental methods, including sampling methodology, analytical procedures, and quality assurance and control methods are presented in Section 2.0. Detailed descriptions of the analytical results are provided in Section 3.0.« less

  15. Headspace techniques in foods, fragrances and flavors: an overview.

    PubMed

    Rouseff, R; Cadwallader, K

    2001-01-01

    Headspace techniques have traditionally involved the collection of volatiles in the vapor state under either dynamic or static conditions as a means of determining concentrations in the product of interest. A brief overview of contemporary headspace applications and recent innovations are presented from the literature and Chapters in this book. New approaches used to concentrate volatiles under static conditions such as solid phase micro extraction, SPME, are examined. Advances in purge and trap applications and automation are also presented. Innovative methods of evaluating headspace volatiles using solid state sensor arrays (electronic noses) or mass spectrometers without prior separation are referenced. Numerous food and beverage headspace techniques are also reviewed. Advantages, limitations and alternatives to headspace analysis are presented.

  16. Some recent developments in headspace gas chromatography

    Treesearch

    J.Y. Zhu; X.-S. Chai

    2005-01-01

    In this study, recent developments in headspace gas chromatography (HSGC) are briefly reviewed. Several novel HSGC techniques developed recently are presented in detail. These techniques were developed using the unique characteristics of the headspace sampling process implemented in commercial HSGC systems and therefore can be easily applied in laboratory and...

  17. Delisting petition for 300-M saltstone (treated F006 sludge) from the 300-M liquid effluent treatment facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1989-04-04

    This petition seeks exclusion for stabilized and solidified sludge material generated by treatment of wastewater from the 300-M aluminum forming and metal finishing processes. The waste contains both hazardous and radioactive components and is classified as a mixed waste. The objective of this petition is to demonstrate that the stabilized sludge material (saltstone), when properly disposed, will not exceed the health-based standards for the hazardous constituents. This petition contains sampling and analytical data which justify the request for exclusion. The results show that when the data are applied to the EPA Vertical and Horizontal Spread (VHS) Model, health-based standards formore » all hazardous waste constituents will not be exceeded during worst case operating and environmental conditions. Disposal of the stabilized sludge material in concrete vaults will meet the requirements pertaining to Waste Management Activities for Groundwater Protection at the Savannah River Site in Aiken, S.C. Documents set forth performance objectives and disposal options for low-level radioactive waste disposal. Concrete vaults specified for disposal of 300-M saltstone (treated F006 sludge) assure that these performance objectives will be met.« less

  18. Assessment of the Impact of a New Guanidine Suppressor In NGS on F/H Laboratory Analyses For DWPF and Saltstone MCU Transfers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bannochie, C. J.

    2013-04-29

    Implementation of the Next Generation Solvent (NGS) in the Modular Caustic-Side Solvent Extraction Unit (MCU) will now proceed with a new suppressor compound, 1,2,3-tris(3,7-dimethyloctyl)guanidine (TiDG), replacing the originally planned suppressor for NGS, 1,3-dicyclohexyl-2-(11-methyldodecyl) guanidine (DCiTG). The Savannah River National Laboratory (SRNL) was tasked with evaluating the potential impact to F/H Laboratory analyses supporting the Defense Waste Processing Facility (DWPF) Waste Acceptance Criteria (WAC) used to qualify transfers of MCU Strip Effluent (SE) into the facility and the Saltstone WAC used to qualify transfers of Tank 50 containing Decontaminated Salt Solution (DSS) from MCU into Saltstone. This assigned scope is coveredmore » by a Task Technical and Quality Assurance Plan (TTQAP). Previous impact evaluations were conducted when the DCiTG suppressor was planned for NGS and concluded that there was no impact to either the determination of MCU SE pH nor the analysis of Isopar® L carryover in the MCU SE and DSS streams. SRNL reported on this series of cross-check studies between the SRNL and F/H Laboratories. The change in suppressor from DCiTG to TiDG in the NGS should not impact the measurement of Isopar® L or pH in SE or DSS necessary to satisfy DWPF and Saltstone WAC (Tank 50) criteria, respectively. A statistical study of the low bias observed in Isopar® L measurements in both SRNL and F/H Laboratories may be necessary now that the final NGS composition is fixed in order to quantify the low bias so that a proper correction can be applied to measurements critical to the DWPF and Saltstone WACs. Depending upon the final DWPF WAC requirement put in place for SE pH, it could become necessary to implement an alternative ICP-AES measurement of boron. The current blended solvent system testing in SRNL should address any impacts to Isopar® L carryover into either the DSS or the SE. It is recommended that SRNL monitor the current blended

  19. AVOIDING HYDROLYSIS OF FUEL ETHER OXYGENATES DURING STATIC HEADSPACE ANALYSIS

    EPA Science Inventory

    A headspace autosampler, gas chromatograph and ion trap mass spectrometer (headspace GC/MS) were used for trace analysis of fuel oxygenates and related compounds and aromatics in water. A method has been developed for determination of methyl tert-butyl ether (MTBE), ethyl tert-b...

  20. Miscibility Evaluation Of The Next Generation Solvent With Polymers Currently Used At DWPF, MCU, And Saltstone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fondeur, F. F.

    The Office of Waste Processing, within the Office of Technology Innovation and Development, funded the development of an enhanced Caustic-Side Solvent Extraction (CSSX) solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. This effort lead to the development of the Next Generation Solvent (NGS) with Tris (3,7-dimethyl octyl) guanidine (TiDG). The first deployment target for the NGS solvent is within the Modular CSSX Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the new chemical components are compatible with the installed equipment. In the instance of a newmore » organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the affected facility. This report provides the calculated data from exposing these polymers to the Next Generation Solvent. An assessment of the dimensional stability of polymers known to be used or present in the MCU, Defense Waste Processing Facility (DWPF), and Saltstone facilities that will be exposed to the NGS showed that TiDG could selectively affect the elastomers and some thermoplastics to varying extents, but the typical use of these polymers in a confined geometry will likely prevent the NGS from impacting component performance. The polymers identified as of primary concern include Grafoil® (flexible graphite), Tefzel®, Isolast®, ethylene-propylene-diene monomer (EPDM) rubber, nitrile-butadiene rubber (NBR), styrene-butadiene rubber (SBR), ultra high molecular weight polyethylene (UHMWPE), and fluorocarbon rubber (FKM). Certain polymers like NBR and EPDM were found to interact mildly with NGS but their calculated swelling and the confined geometry will impede interaction with NGS. In addition, it was found that Vellumoid (cellulose fibers-reinforced glycerin and protein) may leach protein and Polyvinyl Chloride (PVC) may leach plasticizer (such as Bis-Ethylhexyl-Phthalates) into the NGS solvent. Either

  1. Solid-phase microextraction method development for headspace analysis of volatile flavor compounds.

    PubMed

    Roberts, D D; Pollien, P; Milo, C

    2000-06-01

    Solid-phase microextraction (SPME) fibers were evaluated for their ability to adsorb volatile flavor compounds under various conditions with coffee and aqueous flavored solutions. Experiments comparing different fibers showed that poly(dimethylsiloxane)/divinylbenzene had the highest overall sensitivity. Carboxen/poly(dimethylsiloxane) was the most sensitive to small molecules and acids. As the concentrations of compounds increased, the quantitative linear range was exceeded as shown by competition effects with 2-isobutyl-3-methoxypyrazine at concentrations above 1 ppm. A method based on a short-time sampling of the headspace (1 min) was shown to better represent the equilibrium headspace concentration. Analysis of coffee brew with a 1-min headspace adsorption time was verified to be within the linear range for most compounds and thus appropriate for relative headspace quantification. Absolute quantification of volatiles, using isotope dilution assays (IDA), is not subject to biases caused by excess compound concentrations or complex matrices. The degradation of coffee aroma volatiles during storage was followed by relative headspace measurements and absolute quantifications. Both methods gave similar values for 3-methylbutanal, 4-ethylguaiacol, and 2,3-pentanedione. Acetic acid, however, gave higher values during storage upon relative headspace measurements due to concurrent pH decreases that were not seen with IDA.

  2. Simplified multiple headspace extraction gas chromatographic technique for determination of monomer solubility in water.

    PubMed

    Chai, X S; Schork, F J; DeCinque, Anthony

    2005-04-08

    This paper reports an improved headspace gas chromatographic (GC) technique for determination of monomer solubilities in water. The method is based on a multiple headspace extraction GC technique developed previously [X.S. Chai, Q.X. Hou, F.J. Schork, J. Appl. Polym. Sci., in press], but with the major modification in the method calibration technique. As a result, only a few iterations of headspace extraction and GC measurement are required, which avoids the "exhaustive" headspace extraction, and thus the experimental time for each analysis. For highly insoluble monomers, effort must be made to minimize adsorption in the headspace sampling channel, transportation conduit and capillary column by using higher operating temperature and a short capillary column in the headspace sampler and GC system. For highly water soluble monomers, a new calibration method is proposed. The combinations of these technique modifications results in a method that is simple, rapid and automated. While the current focus of the authors is on the determination of monomer solubility in aqueous solutions, the method should be applicable to determination of solubility of any organic in water.

  3. Automated headspace solid-phase dynamic extraction to analyse the volatile fraction of food matrices.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara

    2004-01-23

    High concentration capacity headspace techniques (headspace solid-phase microextraction (HS-SPME) and headspace sorptive extraction (HSSE)) are a bridge between static and dynamic headspace, since they give high concentration factors as does dynamic headspace (D-HS), and are as easy to apply and as reproducible as static headspace (S-HS). In 2000, Chromtech (Idstein, Germany) introduced an inside-needle technique for vapour and liquid sampling, solid-phase dynamic extraction (SPDE), also known as "the magic needle". In SPDE, analytes are concentrated on a 50 microm film of polydimethylsiloxane (PDMS) and activated carbon (10%) coated onto the inside wall of the stainless steel needle (5 cm) of a 2.5 ml gas tight syringe. When SPDE is used for headspace sampling (HS-SPDE), a fixed volume of the headspace of the sample under investigation is sucked up an appropriate number of times with the gas tight syringe and an analyte amount suitable for a reliable GC or GC-MS analysis accumulates in the polymer coating the needle wall. This article describes the preliminary results of both a study on the optimisation of sampling parameters conditioning HS-SPDE recovery, through the analysis of a standard mixture of highly volatile compounds (beta-pinene, isoamyl acetate and linalool) and of the HS-SPDE-GC-MS analyses of aromatic plants and food matrices. This study shows that HS-SPDE is a successful technique for HS-sampling with high concentration capability, good repeatability and intermediate precision, also when it is compared to HS-SPME.

  4. DISSOLVED OXYGEN AND METHANE IN WATER BY A GC HEADSPACE EQUILIBRATION TECHNIQUE

    EPA Science Inventory

    An analytical procedure is described for the determination of dissolved oxygen and methane in groundwater samples. The method consists of generating a helium gas headspace in a water filled bottle, and analysis of the headspace by gas chromatography. Other permanent gases such as...

  5. Influence of headspace pressure on methane production in Biochemical Methane Potential (BMP) tests.

    PubMed

    Valero, David; Montes, Jesús A; Rico, José Luis; Rico, Carlos

    2016-02-01

    The biochemical methane potential test is the most commonly applied method to determine methane production from organic wastes. One of the parameters measured is the volume of biogas produced which can be determined manometrically by keeping the volume constant and measuring increases in pressure. In the present study, the effect of pressure accumulation in the headspace of the reactors has been studied. Triplicate batch trials employing cocoa shell, waste coffee grounds and dairy manure as substrates have been performed under two headspace pressure conditions. The results obtained in the study showed that headspace overpressures higher than 600mbar affected methane production for waste coffee grounds. On the contrary, headspace overpressures within a range of 600-1000mbar did not affect methane production for cocoa shell and dairy manure. With the analyses performed in the present work it has not been possible to determine the reasons for the lower methane yield value obtained for the waste coffee grounds under high headspace pressures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. A double sealing technique for increasing the precision of headspace-gas chromatographic analysis.

    PubMed

    Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian

    2018-01-19

    This paper investigates a new double sealing technique for increasing the precision of the headspace gas chromatographic method. The air leakage problem caused by the high pressure in the headspace vial during the headspace sampling process has a great impact to the measurement precision in the conventional headspace analysis (i.e., single sealing technique). The results (using ethanol solution as the model sample) show that the present technique is effective to minimize such a problem. The double sealing technique has an excellent measurement precision (RSD < 0.15%) and accuracy (recovery = 99.1%-100.6%) for the ethanol quantification. The detection precision of the present method was 10-20 times higher than that in earlier HS-GC work that use conventional single sealing technique. The present double sealing technique may open up a new avenue, and also serve as a general strategy for improving the performance (i.e., accuracy and precision) of headspace analysis of various volatile compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cozzi, A; Cora Berry, C; Michael Bronikowski, M

    The decontaminated salt solution waste stream from the Modular Caustic Side Solvent Extraction Unit and the Salt Waste Processing Facility is anticipated to contain entrained extraction solvent. The decontaminated salt solution is scheduled to be processed through Tank 50 into the Saltstone Production Facility. This study, among others, has been undertaken because the solvent concentration in the decontaminated salt solution may cause flammability issues within the Saltstone Disposal Facility that may need to be addressed prior to operation. Previous work at the Savannah River National Laboratory determined the release of Isopar{reg_sign} L from saltstone prepared with a simulated DSS withmore » Isopar{reg_sign} L concentrations ranging from 50 to 200 {micro}g/g in the salt fraction and with test temperatures ranging from ambient to 95 C. The results from the curing of the saltstone showed that the Isopar{reg_sign} L release data can be treated as a percentage of initial concentration in the concentration range studied. The majority of the Isopar{reg_sign} L that was released over the test duration was released in the first few days. The release of Isopar{reg_sign} L begins immediately and the rate of release decreases over time. At higher temperatures the immediate release is larger than at lower temperatures. In this study, saltstone was prepared using a simulated decontaminated salt solution containing Isopar{reg_sign} L concentrations of 50 {micro}L/L (30 {micro}g/g) and 100 {micro}L/L (61 {micro}g/g) and cured at 55 C. The headspace of each sample was purged and the Isopar{reg_sign} L was trapped on a coconut shell carbon tube. The amount of Isopar{reg_sign} L captured was determined using NIOSH Method 1501. The percentage of Isopar{reg_sign} L released after 20 days was 1.4 - 3.7% for saltstone containing 50 {micro}L/L concentration and 2.1 - 4.3% for saltstone containing 100 {micro}L/L concentration. Given the measurement uncertainties in this work there

  8. [Analytical method and comparison for static and dynamic headspace gas chromatography of anisole in water].

    PubMed

    Zhang, Yan; Qian, Jie-feng; Liu, Lan-xia; Zhao, Hui-qin

    2013-01-01

    To establish and compare the method of static headspace gas chromatography hydrogen flame detector (static headspace method) and purge and trap gas chromatography-mass spectrometry (dynamic headspace method) of anisole in water. Nitrogen gas was used as carrier gas in the static headspace method, 5 g NaCl as matrix modifier was added into 10 ml water. The sample was balanced with high speed vibration at 75°C for 30 min, and anisole was detected by gas chromatography and quantified with external standard. Helium was used as carrier gas in dynamic headspace method, 5.0 ml water and 0.004 mg/L internal standard fluorobenzene was purged into the purge and trap apparatus. After purging, trapping and desorption, anisole was detected by the gas chromatography-mass spectrograph, confirmed by the retention time and comparison of mass-spectrogram in spectrum library and quantified with internal standard. The repeatability and sensitivity of assay were evaluated. A good linear range for anisole was observed in static headspace gas chromatography and dynamic headspace gas chromatography-mass spectrometry, within the range of 10 - 500 µg/L and 0.5 - 60.0 µg/L respectively. The linear regression equation was Y = 782.150X + 1.3446 and Y = 0.0358X - 0.0209 respectively, both the correlation coefficient ≥ 0.999. The detection limit (LOD) were 0.002 µg/L and 0.110 µg/L, the lower limit of quantitation (LOQ) were 0.006 µg/L and 0.350 µg/L, the relative standard deviation (RSD) were 1.8% - 2.3% and 2.0% - 3.4%, and the spiking recovery were 93% - 101% and 96% - 101% respectively. The methods of static headspace gas chromatography and dynamic headspace gas chromatography-mass spectrometry are simple and can measure anisole in water quickly, sensitively and accurately.

  9. Evaluation of headspace equilibration methods for quantifying greenhouse gases in groundwater.

    PubMed

    Jahangir, M M R; Johnston, P; Khalil, M I; Grant, J; Somers, C; Richards, K G

    2012-11-30

    The objective of the study was to evaluate the different headspace equilibration methods for the quantification of dissolved greenhouse gases in groundwater. Groundwater samples were collected from wells with contrasting hydrogeochemical properties and degassed using the headspace equilibration method. One hundred samples from each well were randomly selected, treatments were applied and headspace gases analysed by gas chromatography. Headspace equilibration treatments varied helium (He):water ratio, shaking time and standing time. Mean groundwater N(2)O, CO(2) and CH(4) concentrations were 0.024 mg N L(-1), 13.71 mg C L(-1) and 1.63 μg C L(-1), respectively. All treatments were found to significantly influence dissolved gas concentrations. Considerable differences in the optimal He:water ratio and standing time were observed between the three gases. For N(2)O, CO(2) and CH(4) the optimum operating points for He:water ratio was 4.4:1, 3:1 and 3.4:1; shaking time was 13, 12 and 13 min; and standing time was 63, 17 and 108 min, respectively. The headspace equilibration method needs to be harmonised to ensure comparability between studies. The experiment reveals that He:water ratio 3:1 and shaking time 13 min give better estimation of dissolved gases than any lower or higher ratios and shaking times. The standing time 63, 17 and 108 min should be applied for N(2)O, CO(2) and CH(4), respectively. Copyright © 2012. Published by Elsevier Ltd.

  10. Static headspace analysis using polyurethane phases--application to roasted coffee volatiles characterization.

    PubMed

    Rodrigues, C; Portugal, F C M; Nogueira, J M F

    2012-01-30

    Static headspace sorptive extraction using polyurethane foams (HSSE(PU)) followed by gas chromatography coupled to mass spectrometry is proposed for volatile analysis. The application of this novel analytical approach to characterize the volatiles profile from roasted coffee samples, selected as model system, revealed remarkable advantages under convenient experimental conditions. The comparison of HSSE(PU) with other well-established procedures, such as headspace sorptive extraction using polydimethylsiloxane (HSSE(PDMS)) and headspace solid phase microextraction using carboxen/polydimethylsiloxane fibers (HS-SPME(CAR/PDMS)), showed that the former presented much higher capacity, sensitivity and even selectivity, where larger abundance and number of roasted coffee volatile compounds (e.g. furans, pyrazines, ketones, acids and pyrroles) could be achieved, under similar experimental conditions. The data presented herein proved, for the first time, that PU foams present great performance for static headspace sorption-based procedures, showing to be an alternative polymeric phase for volatile analysis. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. NUMERICAL FLOW AND TRANSPORT SIMULATIONS SUPPORTING THE SALTSTONE FACILITY PERFORMANCE ASSESSMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flach, G.

    2009-02-28

    The Saltstone Disposal Facility Performance Assessment (PA) is being revised to incorporate requirements of Section 3116 of the Ronald W. Reagan National Defense Authorization Act for Fiscal Year 2005 (NDAA), and updated data and understanding of vault performance since the 1992 PA (Cook and Fowler 1992) and related Special Analyses. A hybrid approach was chosen for modeling contaminant transport from vaults and future disposal cells to exposure points. A higher resolution, largely deterministic, analysis is performed on a best-estimate Base Case scenario using the PORFLOW numerical analysis code. a few additional sensitivity cases are simulated to examine alternative scenarios andmore » parameter settings. Stochastic analysis is performed on a simpler representation of the SDF system using the GoldSim code to estimate uncertainty and sensitivity about the Base Case. This report describes development of PORFLOW models supporting the SDF PA, and presents sample results to illustrate model behaviors and define impacts relative to key facility performance objectives. The SDF PA document, when issued, should be consulted for a comprehensive presentation of results.« less

  12. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    PubMed

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  13. Critical aspects for the reliable headspace analysis of plants cultivated in vitro.

    PubMed

    Maes, K; Vercammen, J; Pham-Tuan, H; Sandra, P; Debergh, P C

    2001-01-01

    Various factors controlling the recoveries of volatile organic compounds in vitro headspace analysis of tomato plants (Lycopersicon esculentum Mill. 'Moneymaker'), sampled using solid phase micro-extraction, were evaluated and optimised. The variations in composition of the headspaces were determined as a function of time, and following in vitro wounding of the plant.

  14. Headspace Gas Chromatography Method for Studies of Reaction and Permeation of Volatile Agents with Solid Materials

    DTIC Science & Technology

    2015-01-01

    HEADSPACE GAS CHROMATOGRAPHY METHOD FOR STUDIES OF REACTION AND PERMEATION OF...TITLE AND SUBTITLE Headspace Gas Chromatography Method for Studies of Reaction and Permeation of Volatile Agents with Solid Materials 5a...method is described for measuring the reactivity and permeability of fabrics, films, and other solid materials. Headspace gas chromatography (GC)

  15. Technical note: Headspace analysis of explosive compounds using a novel sampling chamber.

    PubMed

    DeGreeff, Lauryn; Rogers, Duane A; Katilie, Christopher; Johnson, Kevin; Rose-Pehrsson, Susan

    2015-03-01

    The development of instruments and methods for explosive vapor detection is a continually evolving field of interest. A thorough understanding of the characteristic vapor signatures of explosive material is imperative for the development and testing of new and current detectors. In this research a headspace sampling chamber was designed to contain explosive materials for the controlled, reproducible sampling and characterization of vapors associated with these materials. In a detonation test, the chamber was shown to contain an explosion equivalent to three grams of trinitrotoluene (TNT) without damage to the chamber. The efficacy of the chamber in controlled headspace sampling was evaluated in laboratory tests with bulk explosive materials. Small quantities of TNT, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD) were separately placed in the sampling chamber, and the headspace of each material was analyzed by gas chromatography/mass spectrometry (GC/MS) with online cryogenic trapping to yield characteristic vapor signatures for each explosive compound. Chamber sampling conditions, temperature and sampling time, were varied to demonstrate suitability for precise headspace analysis. Published by Elsevier Ireland Ltd.

  16. Reactive amendment saltstone (RAS). A novel approach for improved sorption/retention of radionuclides such as technetium and iodine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, K. L.; Knox, A. S.; Cozzi, A. D.

    This study examined the use of reactive amendments (hydroxyapatite, activated carbon, and two types of organoclays) that prior research suggests may improve retention of 99Tc and 129I. Tests were conducted using surrogates for 99Tc (NaReO 4) and 129I (NaI). Results showed that adding up to 10% of organoclay improved the retention of Re without adversely impacting hydraulic properties. To a lesser extent, iodine retention was also improved by adding up to 10% organoclay. Numerical modeling showed that using organoclay as a reactive barrier may significantly retard 99Tc release from saltstone disposal units.

  17. Headspace volume and percentage of carbon monoxide affects carboxymyoglobin layer development of modified atmosphere packaged beef steaks.

    PubMed

    Raines, Christopher R; Hunt, Melvin C

    2010-01-01

    Carboxymyoglobin (COMb) development of beef Longissimus lumborum as related to molecular CO availability and package headspace volume was evaluated. Steaks from six pairs of USDA Select strip loins were packaged in modified atmosphere packages with 0.2%, 0.4%, or 0.8% CO and 30% CO(2) and balanced with N(2) to obtain meat-to-gas ratios of 0.4, 0.7, and 1.1, and CO molar concentrations of 0.07, 0.10, and 0.20 mMol. Steak redness (CIE a*), COMb layer thickness, percentage of CO in the headspace, visual display color, and bloom intensity scores were evaluated 4 and 7 d after packaging. Greater concentration of CO in a smaller headspace resulted in a thicker COMb layer compared with lesser concentration of CO in a larger headspace, regardless of moles CO available. The combined effects of concentration of CO and headspace volume had a greater impact on COMb development than millimoles of CO in the package headspace. Package headspace can be reduced and the concentration of CO can be increased without detriment to fresh beef color or consumer safety.

  18. Simplex Optimization of Headspace-Enrichment Conditions of Residual Petroleum Distillates Used by Arsonists

    ERIC Educational Resources Information Center

    Warnke, Molly M.; Erickson, Angela E.; Smith, Eugene T.

    2005-01-01

    A forensic project is described that is suitable for an undergraduate instrumental methods lab. Accelerants commonly used by arsonists are analyzed by static headspace enrichment followed by gas chromatography. The conditions used for headspace enrichment (e.g., time and temperature) are known to influence the distribution of hydrocarbons…

  19. Simple and accurate method for determining dissolved inorganic carbon in environmental water by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-03-01

    We investigate a simple and accurate method for quantitatively analyzing dissolved inorganic carbon in environmental water by reaction headspace gas chromatography. The neutralization reaction between the inorganic carbon species (i.e. bicarbonate ions and carbonate ions) in environmental water and hydrochloric acid is carried out in a sealed headspace vial, and the carbon dioxide formed from the neutralization reaction, the self-decomposition of carbonic acid, and dissolved carbon dioxide in environmental water is then analyzed by headspace gas chromatography. The data show that the headspace gas chromatography method has good precision (relative standard deviation ≤ 1.63%) and accuracy (relative differences ≤ 5.81% compared with the coulometric titration technique). The headspace gas chromatography method is simple, reliable, and can be well applied in the dissolved inorganic carbon detection in environmental water. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Disposable remote zero headspace extractor

    DOEpatents

    Hand, Julie J [Idaho Falls, ID; Roberts, Mark P [Arco, ID

    2006-03-21

    The remote zero headspace extractor uses a sampling container inside a stainless steel vessel to perform toxicity characteristics leaching procedure to analyze volatile organic compounds. The system uses an in line filter for ease of replacement. This eliminates cleaning and disassembly of the extractor. All connections are made with quick connect fittings which can be easily replaced. After use, the bag can be removed and disposed of, and a new sampling container is inserted for the next extraction.

  1. Fast characterization of cheeses by dynamic headspace-mass spectrometry.

    PubMed

    Pérès, Christophe; Denoyer, Christian; Tournayre, Pascal; Berdagué, Jean-Louis

    2002-03-15

    This study describes a rapid method to characterize cheeses by analysis of their volatile fraction using dynamic headspace-mass spectrometry. Major factors governing the extraction and concentration of the volatile components were first studied. These components were extracted from the headspace of the cheeses in a stream of helium and concentrated on a Tenax TA trap. They were then desorbed by heating and injected directly into the source of a mass spectrometer via a short deactivated silica transfer line. The mass spectra of the mixture of volatile components were considered as fingerprints of the analyzed substances. Forward stepwise factorial discriminant analysis afforded a limited number of characteristic mass fragments that allowed a good classification of the batches of cheeses studied.

  2. Determinations of dimethylsulphoniopropionate (DMSP) lyase activity using headspace analysis of dimethylsulphide (DMS)

    NASA Astrophysics Data System (ADS)

    Steinke, M.; Malin, G.; Turner, S. M.; Liss, P. S.

    2000-08-01

    The osmolyte dimethylsulphoniopropionate (DMSP) can be enzymatically cleaved to dimethylsulphide (DMS), acrylate and a proton. The enzyme involved in this reaction is dimethylpropiothetin dethiomethylase (DMSP lyase; enzyme classification number 4.4.1.3.). Although the importance of this reaction for the global sulphur cycle, the influence of DMS on atmospheric acidity and the possible effect on climate regulation have been widely recognised, our knowledge of DMSP lyases is limited to just a few studies. Activity measurements of DMSP lyases offer an important step towards a better understanding of the conditions under which DMS is produced. In the available published data somewhat similar methods have been used before, but a critical examination of the method limitations has not been reported. To encourage further research on this enzyme, we suggest and detail two protocols for measurements of DMSP lyase activity: An in vitro assay for crude cell extracts or purified enzyme and an in vivo method for whole cells, which we recently started to use. After addition of DMSP, samples incubated in a gas tight vial may produce DMS from enzymatic cleavage under suitable conditions, and a DMS production rate can be estimated from time-series measurements of DMS in the headspace of the vial. Headspace analysis of DMS is a useful and rapid technique to estimate and compare DMSP lyase activities from different sources. The relative rates of DMS production in the liquid and of the gas transfer between liquid and headspace, determine the rate of DMS production measured via headspace analysis. If DMS production in the liquid is higher than the rate of transfer, headspace measurements will not reflect the actual amount of DMS produced in the liquid. In this case, extracts have to be diluted to a level that ensures linearity between dilution factor and reduction of enzyme activity. Additionally, incubation volumes and vials should be selected to provide a high surface-to-volume ratio

  3. Determination of residual acetone and acetone related impurities in drug product intermediates prepared as Spray Dried Dispersions (SDD) using gas chromatography with headspace autosampling (GCHS).

    PubMed

    Quirk, Emma; Doggett, Adrian; Bretnall, Alison

    2014-08-05

    Spray Dried Dispersions (SDD) are uniform mixtures of a specific ratio of amorphous active pharmaceutical ingredient (API) and polymer prepared via a spray drying process. Volatile solvents are employed during spray drying to facilitate the formation of the SDD material. Following manufacture, analytical methodology is required to determine residual levels of the spray drying solvent and its associated impurities. Due to the high level of polymer in the SDD samples, direct liquid injection with Gas Chromatography (GC) is not a viable option for analysis. This work describes the development and validation of an analytical approach to determine residual levels of acetone and acetone related impurities, mesityl oxide (MO) and diacetone alcohol (DAA), in drug product intermediates prepared as SDDs using GC with headspace (HS) autosampling. The method development for these analytes presented a number of analytical challenges which had to be overcome before the levels of the volatiles of interest could be accurately quantified. GCHS could be used after two critical factors were implemented; (1) calculation and application of conversion factors to 'correct' for the reactions occurring between acetone, MO and DAA during generation of the headspace volume for analysis, and the addition of an equivalent amount of polymer into all reference solutions used for quantitation to ensure comparability between the headspace volumes generated for both samples and external standards. This work describes the method development and optimisation of the standard preparation, the headspace autosampler operating parameters and the chromatographic conditions, together with a summary of the validation of the methodology. The approach has been demonstrated to be robust and suitable to accurately determine levels of acetone, MO and DAA in SDD materials over the linear concentration range 0.008-0.4μL/mL, with minimum quantitation limits of 20ppm for acetone and MO, and 80ppm for DAA. Copyright

  4. headspace - Australia's innovation in youth mental health: who are the clients and why are they presenting?

    PubMed

    Rickwood, Debra J; Telford, Nic R; Parker, Alexandra G; Tanti, Chris J; McGorry, Patrick D

    2014-02-03

    To provide the first national profile of the characteristics of young people (aged 12-25 years) accessing headspace centre services - the Australian Government's innovation in youth mental health service delivery - and investigate whether headspace is providing early service access for adolescents and young adults with emerging mental health problems. Census of all young people accessing a headspace centre across the national network of 55 centres comprising a total of 21 274 headspace clients between 1 January and 30 June 2013. Reason for presentation, Kessler Psychological Distress Scale, stage of illness, diagnosis, functioning. Young people were most likely to present with mood and anxiety symptoms and disorders, self-reporting their reason for attendance as problems with how they felt. Client demographic characteristics tended to reflect population-level distributions, although clients from regional areas and of Aboriginal and Torres Strait Islander background were particularly well represented, whereas those who were born outside Australia were underrepresented. headspace centres are providing a point of service access for young Australians with high levels of psychological distress and need for care in the early stages of the development of mental disorder.

  5. Effect of Subcritical Fluid Extraction on the High Quality of Headspace Oil from Jasminum sambac (L.) Aiton.

    PubMed

    Ye, Qiuping; Jin, Xinyi; Wei, Shiqin; Zheng, Gongyu; Li, Xinlei

    2016-05-01

    Subcritical fluid extraction (SFE), as a novel method, was applied to investigate the yield, quality, and sensory evaluation of headspace oil from Jasminum sambac (L.) Aiton in comparison with petroleum ether extraction (PEE). The results indicated that the yield of the headspace oil using SFE was significantly higher (P < 0.05) than when using PEE. SFE contributed to obtaining alcohols and ethers, prevented the thermal reaction of terpenes, and reduced α-caryophyllene and β-caryophyllene in the headspace oil. The contents of linalool (21.90%) and benzyl acetate (16.31%) were higher via SFE than PEE. In addition, the sensory evaluation of SFE was superior to PEE, indicating a fresh, jasmine-like odor and green-yellow color. Thus, SFE is an improved method for obtaining natural headspace oil from jasmine flowers.

  6. Quantification of anhydride groups in anhydride-based epoxy hardeners by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-06-01

    We demonstrate a reaction headspace gas chromatographic method for quantifying anhydride groups in anhydride-based epoxy hardeners. In this method, the conversion process of anhydride groups can be realized by two steps. In the first step, anhydride groups in anhydride-based epoxy hardeners completely reacted with water to form carboxyl groups. In the second step, the carboxyl groups reacted with sodium bicarbonate solution in a closed sample vial. After the complete reaction between the carboxyl groups and sodium bicarbonate, the CO 2 formed from this reaction was then measured by headspace gas chromatography. The data showed that the reaction in the closed headspace vial can be completed in 15 min at 55°C, the relative standard deviation of the reaction headspace gas chromatography method in the precision test was less than 3.94%, the relative differences between the new method and a reference method were no more than 9.38%. The present reaction method is automated, efficient and can be a reliable tool for quantifying the anhydride groups in anhydride-based epoxy hardeners and related research. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Headspace gas chromatography of volatile lipid peroxidation products from human red blood cell membranes.

    PubMed

    Frankel, E N; Tappel, A L

    1991-06-01

    An improved headspace capillary gas chromatographic (GC) method was developed to measure the oxidative susceptibility of human red blood cell (RBC) membranes. This method analyzed volatile peroxidation products of both n-6 (hexanal and pentane) and n-3 (propanal) polyunsaturated fatty acids. Oxidative susceptibility tests were standardized by incubating in a sealed 10-mL headspace bottle 0.25 or 1 mL of human RBC membrane in 40 mM phosphate buffer for 1 hr at 37 degrees C with a mixture of Fe++, ascorbic acid and H2O2. Sodium dodecyl sulfate increased significantly the amount of hexanal measured by headspace GC. By this standard headspace method, in one series of red blood cell membranes (RBCM) samples a four-fold variation in oxidative susceptibility was observed in RBCM from blood freshly drawn from six healthy subjects. In another series of RBCM samples a sixteen-fold variation in oxidative susceptibility was noted in frozen RBCM from blood freshly drawn from five healthy subjects. Correlation between hexanal formation and polyunsaturated fatty acids (PUFA) depletion provided good evidence that under these standard conditions hexanal is exclusively derived from the oxidation of arachidonic acid. Hydroperoxides of arachidonic acid are more readily formed and decomposed than those of linoleic acid in the presence of Fe++, ascorbic acid and H2O2 to produce hexanal as the main product that can be readily analyzed by headspace GC. This method may provide a useful tool to study susceptibility toward lipid peroxidative damage in human RBC membranes.

  8. Methyl bromide determination in selected foods by headspace technique.

    PubMed

    Daft, J L

    1993-01-01

    A headspace method used earlier for determining methyl bromide (MB) in assorted nuts and peanut butters has been successfully applied to other foods that could potentially contain traces of this toxic fumigant. The foods tested include 63 off-the-shelf spices and seasonings, 83 table-ready items (grain-based, dried, or highly seasoned), 30 dried fruits and trail mixes, and 38 oil-based items (oil-seeds, cooking oils, or spicy oil-based dressings). Sample headspace gas is produced by blending < or = 50 g sample in 250 +/- 50 mL aqueous solution in a sealed 1000 mL blender cup. After equilibration at 25 degrees C, the headspace is sampled with a gas-tight syringe and injected into a dual column-dual detector gas chromatograph. One determination is made with a 20% OV-101 packed column and a 63Ni electron capture detector (ECD), the other with a GS-Q wide-bore capillary column and a Hall electrolytic conductivity detector (HECD). Of the approximately 200 samples tested, none contained detectable MB residue at a quantitation limit < 100 ng/g sample. All fortified samples yielded MB recovery. Samples were fortified at levels ranging from 78 to 3250 ng MB/g. Recoveries ranged from a mean high of 56% for spices and seasonings to a mean low of 30% for oil-based foods. The overall recovery and CV, including the results from assorted nuts and peanut butters, were 46 and 33%, respectively.

  9. Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique.

    PubMed

    Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian

    2018-04-17

    The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Reversed headspace analysis for characterization, identification, and analysis of solid and liquid matrices: Part I.

    PubMed

    Markelov, M; Bershevits, O

    2006-03-01

    This paper offers a methodology of an experimentally simple reversed headspace (RHS) analysis for measuring of matrix effects and their use for identification and characterization of condensed matrices such as pharmaceuticals, polymers, chromatographic packing, etc. applicable for both quality control monitoring and research and development investigation. In RHS methods, the matrix is spiked and equilibrated with a mixture of volatile chemicals containing various functional groups (molecular sensor array or MSA mixture). Headspace chromatograms of the same spikes of a sample and an empty vial are compared. Examination of basic headspace theory shows that matrix specific constants (M), rather than partition coefficients (K), can be calculated from the headspace chromatograms and M=(K-1)xbeta, where beta is a degree of matrix volume change during equilibration. Matrix specific constants can be plotted against any property of chemicals (polarity, dielectric constant, solubility parameter, vapor pressure, etc.) or just against a set of consecutive numbers, each representing a chemical in MSA. This plot is, in a sense, a molecular affinity spectrum (MAS) specific for a given matrix at a given temperature and is independent of an instrument. Changes in MAS that correspond to chemicals with a particular functional group give an insight to the type of differences between matrices and may quantitatively define them.

  11. Determination of chlorinated volatile organic compounds in polyamine epichlorohydrin solution by headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan

    2017-05-05

    This study demonstrated a headspace gas chromatographic (HS-GC) method for the determination of residual epichlorohydrin (ECH) and the by-product 1,3-dichloro-2-propanol (DCP) in polyamine epichlorohydrin (PAE) solution. It was based on the vapor-liquid phase equilibrium of these analytes at 60°C for 30min in a closed headspace sample vial before GC measurement. It was found that matrix of the PAE solution had the effect on the headspace equilibrium of these species and therefore a standard addition must be applied in the method validation. The results showed that the present method has a good measurement precision (RSD <2.90%) and accuracy (recoveries from 93.6 to 105%), and the limit of quantitation (LOQ) is 3.75mg/L for ECH and 0.8g/L for DCP. The present method is suitable to be used for analyzing the chlorinated volatile organic compounds in the commercial PAE resin solutions. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Rapid method for determination of carbonyl groups in lignin compounds by headspace gas chromatography.

    PubMed

    Li, Jing; Hu, Hui-Chao; Chai, Xin-Sheng

    2015-07-24

    The paper reports on a novel method for rapid determination of carbonyl in lignins by headspace gas chromatography (HS-GC). The method involves the quantitative carbonyl reduction for aldehydes in 2min at room temperature or for acetones in 30min at 80°C by sodium borohydride solution in a closed headspace sample vial. After the reaction, the solution was acidified by injecting sulfuric acid solution and the hydrogen released to the headspace was determined by GC using thermal-conductivity detector. The results showed that with the addition of SiO2 powder, the reduction reaction of carbonyl groups can be greatly facilitated. The method has a good measurement precision (RSD<7.74%) and accuracy (relative error <10% compared with a reference method) in the carbonyl quantification. It is suitable to be used for rapid determination of carbonyl content in lignin and related materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Method Development for Container Closure Integrity Evaluation via Headspace Gas Ingress by Using Frequency Modulation Spectroscopy.

    PubMed

    Victor, Ken G; Levac, Lauren; Timmins, Michael; Veale, James

    2017-01-01

    USP <1207.1> Section 3.5 states that "A deterministic leak test method having the ability to detect leaks at the product's maximum allowable leakage limit is preferred when establishing the inherent integrity of a container-closure system." Ideally, container closure integrity of parenteral packaging would be evaluated by measuring a physical property that is sensitive to the presence of any package defect that breaches package integrity by increasing its leakage above its maximum allowable leakage limit. The primary goals of the work presented herein were to demonstrate the viability of the nondestructive, deterministic method known as laser-based gas headspace analysis for evaluating container closure integrity and to provide a physical model for predicting leak rates for a variety of container volumes, headspace conditions, and defect sizes. The results demonstrate that laser-based headspace analysis provides sensitive, accurate, and reproducible measurements of the gas ingress into glass vial-stopper package assemblies that are under either diffusive or effusive leak conditions. Two different types of positive controls were examined. First, laser-drilled micro-holes in thin metal disks that were crimped on top of 15R glass vials served as positive controls with a well-characterized defect geometry. For these, a strong correlation was observed between the measured ingress parameter and the size of the defect for both diffusive and effusive conditions. Second, laser-drilled holes in the wall of glass vials served as controls that more closely simulate real-world defects. Due to their complex defect geometries, their diffusive and effusive ingress parameters did not necessarily correlate; this is an important observation that has significant implications for standardizing the characterization of container defects. Regardless, laser-based headspace analysis could readily differentiate positive and negative controls for all leak conditions, and the results provide a

  14. Electroantennographic and behavioral responses of the sphinx moth Manduca sexta to host plant headspace volatiles.

    PubMed

    Fraser, Ann M; Mechaber, Wendy L; Hildebrand, John G

    2003-08-01

    Coupled gas chromatography with electroantennographic detection (GC-EAD) using antennae of adult female Manduca sexta was employed to screen for olfactory stimulants present in headspace collections from four species of larval host plants belonging to two families: Solanaceae--Lycopersicon esculentum (tomato), Capiscum annuum (bell pepper), and Datura wrightii; and Martyniaceae--Pronboscideaparviflora. Headspace volatiles were collected from undamaged foliage of potted, living plants. GC-EAD revealed 23 EAD-active compounds, of which 15 were identified by GC-mass spectrometry. Identified compounds included aliphatic, aromatic, and terpenoid compounds bearing a range of functional groups. Nine EAD-active compounds were common to all four host plant species: (Z)-3-hexenyl acetate, nonanal, decanal, phenylacetaldehyde, methyl salicylate, benzyl alcohol, geranyl acetone, (E)-nerolidol, and one unidentified compound. Behavioral responses of female moths to an eight-component synthetic blend of selected tomato headspace volatiles were tested in a laboratory wind tunnel. Females were attracted to the blend. A comparison of responses from antennae of males and females to bell pepper headspace volatiles revealed that males responded to the same suite of volatiles as females, except for (Z)-3-hexenyl benzoate. EAD responses of males also were lower for (Z)-and (E)-nerolidol and one unidentified compound. Electroantennogram EAG dose-response curves for the 15 identified EAD-active volatiles were recorded. At the higher test doses (10-100 microg), female antennae yielded larger EAG responses to terpenoids and to aliphatic and aromatic esters. Male antennae did respond to the higher doses of (Z)-3-hexenyl benzoate, indicating that they can detect this compound. On the basis of ubiquity of the EAD-active volatiles identified to date in host plant headspace collections, we suggest that M. sexta uses a suite of volatiles to locate and identify appropriate host plants.

  15. Quantitative analysis of perfumes in talcum powder by using headspace sorptive extraction.

    PubMed

    Ng, Khim Hui; Heng, Audrey; Osborne, Murray

    2012-03-01

    Quantitative analysis of perfume dosage in talcum powder has been a challenge due to interference of the matrix and has so far not been widely reported. In this study, headspace sorptive extraction (HSSE) was validated as a solventless sample preparation method for the extraction and enrichment of perfume raw materials from talcum powder. Sample enrichment is performed on a thick film of poly(dimethylsiloxane) (PDMS) coated onto a magnetic stir bar incorporated in a glass jacket. Sampling is done by placing the PDMS stir bar in the headspace vial by using a holder. The stir bar is then thermally desorbed online with capillary gas chromatography-mass spectrometry. The HSSE method is based on the same principles as headspace solid-phase microextraction (HS-SPME). Nevertheless, a relatively larger amount of extracting phase is coated on the stir bar as compared to SPME. Sample amount and extraction time were optimized in this study. The method has shown good repeatability (with relative standard deviation no higher than 12.5%) and excellent linearity with correlation coefficients above 0.99 for all analytes. The method was also successfully applied in the quantitative analysis of talcum powder spiked with perfume at different dosages. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Gas flow headspace liquid phase microextraction.

    PubMed

    Yang, Cui; Qiu, Jinxue; Ren, Chunyan; Piao, Xiangfan; Li, Xifeng; Wu, Xue; Li, Donghao

    2009-11-06

    There is a trend towards the use of enrichment techniques such as microextraction in the analysis of trace chemicals. Based on the theory of ideal gases, theory of gas chromatography and the original headspace liquid phase microextraction (HS-LPME) technique, a simple gas flow headspace liquid phase microextraction (GF-HS-LPME) technique has been developed, where the extracting gas phase volume is increased using a gas flow. The system is an open system, where an inert gas containing the target compounds flows continuously through a special gas outlet channel (D=1.8mm), and the target compounds are trapped on a solvent microdrop (2.4 microL) hanging on the microsyringe tip, as a result, a high enrichment factor is obtained. The parameters affecting the enrichment factor, such as the gas flow rate, the position of the microdrop, the diameter of the gas outlet channel, the temperatures of the extracting solvent and of the sample, and the extraction time, were systematically optimized for four types of polycyclic aromatic hydrocarbons. The results were compared with results obtained from HS-LPME. Under the optimized conditions (where the extraction time and the volume of the extracting sample vial were fixed at 20min and 10mL, respectively), detection limits (S/N=3) were approximately a factor of 4 lower than those for the original HS-LPME technique. The method was validated by comparison of the GF-HS-LPME and HS-LPME techniques using data for PAHs from environmental sediment samples.

  17. Efficient determination of average valence of manganese in manganese oxides by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-08-18

    This work investigates a new reaction headspace gas chromatographic (HS-GC) technique for efficient quantifying average valence of manganese (Mn) in manganese oxides. This method is on the basis of the oxidation reaction between manganese oxides and sodium oxalate under the acidic condition. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively analyzed by headspace gas chromatography. The data showed that the reaction in the closed headspace vial can be completed in 20min at 80°C. The relative standard deviation of this reaction HS-GC method in the precision testing was within 1.08%, the relative differences between the new method and the reference method (titration method) were no more than 5.71%. The new HS-GC method is automated, efficient, and can be a reliable tool for the quantitative analysis of average valence of manganese in the manganese oxide related research and applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Extraction of toxic compounds from saliva by magnetic-stirring-assisted micro-solid-phase extraction step followed by headspace-gas chromatography-ion mobility spectrometry.

    PubMed

    Criado-García, Laura; Arce, Lourdes

    2016-09-01

    A new sample extraction procedure based on micro-solid-phase extraction (μSPE) using a mixture of sorbents of different polarities (polymeric reversed-phase sorbent HLB, silica-based sorbent C18, and multiwalled carbon nanotubes) was applied to extract benzene, toluene, butyraldehyde, benzaldehyde, and tolualdehyde present in saliva to avoid interference from moisture and matrix components and enhance sensitivity and selectivity of the ion mobility spectrometry (IMS) methodology proposed. The extraction of target analytes from saliva samples by using μSPE were followed by the desorption step carried out in the headspace vials placed in the autosampler of the IMS device. Then, 200 μL of headspace was injected into the GC column coupled to the IMS for its analysis. The method was fully validated in terms of sensitivity, precision, and recovery. The LODs and LOQs obtained, when analytes were dissolved in saliva samples to consider the matrix effect, were within the range of 0.38-0.49 and 1.26-1.66 μg mL(-1), respectively. The relative standard deviations were <3.5 % for retention time and drift time values, which indicate that the method proposed can be applied to determine toxic compounds in saliva samples. Graphical abstract Summary of steps followed in the experimental set up of this work.

  19. An Economical Method for Static Headspace Enrichment for Arson Analysis

    ERIC Educational Resources Information Center

    Olesen, Bjorn

    2010-01-01

    Static headspace analysis of accelerants from suspected arsons is accomplished by placing an arson sample in a sealed container with a carbon strip suspended above the sample. The sample is heated, cooled to room temperature, and then the organic components are extracted from the carbon strip with carbon disulfide followed by gas chromatography…

  20. Determination of microstickies in recycled whitewater by headspace gas chromatography

    Treesearch

    X.-S. Chai; J.C. Samp; Q.F. Yang; H.N. Song; J.Y. Zhu

    2007-01-01

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid...

  1. Comparative analysis of the vapor headspace of military-grade TNT versus NESTT TNT under dynamic and static conditions

    NASA Astrophysics Data System (ADS)

    Edge, Cindy C.; Gibb, Julie; Wasserzug, Louis S.

    1998-09-01

    The Institute for Biological Detection Systems (IBDS) has developed a quantitative vapor delivery system that can aid in characterizing dog's sensitivity and ability to recognize odor signatures for explosives and contraband substances. Determining of the dog's odor signature for detection of explosives is important because it may aid in eliminating the risk of handling explosives and reducing cross-contamination. Progress is being made in the development of training aids that represent the headspace of the explosives. NESTTTM TNT materials have been proposed as an approach to developing training aid simulates. In order for such aids to be effective they must mimic the headspace of the target material. This study evaluates the NESTTTM TNT product with regard to this criterion. NESTTTM TNT vapor was generated by the IBDS vapor delivery system, which incorporates a vapor generation cell that enables the user to control the conditions under which a substance is tested. The NESTTTM TNT vapor was compared to the headspace of military-grade TNT. The findings identify and quantify major vapor constituents of military-grade TNT and NESTTTM TNT. A comparative analysis evaluated the degree to which the NESTTTM TNT mimics the headspace of an actual TNT sample.

  2. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    ERIC Educational Resources Information Center

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-01-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal…

  3. Analysis of Volatile Fragrance and Flavor Compounds by Headspace Solid Phase Microextraction and GC-MS: An Undergraduate Instrumental Analysis Experiment

    NASA Astrophysics Data System (ADS)

    Galipo, Randolph C.; Canhoto, Alfredo J.; Walla, Michael D.; Morgan, Stephen L.

    1999-02-01

    A senior-level undergraduate laboratory experiment that demonstrates the use of solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS) was developed for the identification of volatile compounds in consumer products. SPME minimizes sample preparation and concentrates volatile analytes in a solvent-free manner. Volatile flavor and fragrance compounds were extracted by SPME from the headspace of vials containing shampoos, chewing gums, and perfumes and analyzed by GC-MS. Headspace SPME was shown to be more sensitive than conventional headspace analysis of similar samples performed with an airtight syringe. Analysis times were less than 30 min, allowing multiple analyses to be performed in a typical laboratory class period.

  4. Factors controlling headspace pressure in a manual manometric BMP method can be used to produce a methane output comparable to AMPTS.

    PubMed

    Himanshu, H; Voelklein, M A; Murphy, J D; Grant, J; O'Kiely, P

    2017-08-01

    The manual manometric biochemical methane potential (mBMP) test uses the increase in pressure to calculate the gas produced. This gas production may be affected by the headspace volume in the incubation bottle and by the overhead pressure measurement and release (OHPMR) frequency. The biogas and methane yields of cellulose, barley, silage and slurry were compared with three incubation bottle headspace volumes (50, 90 and 180ml; constant 70ml total medium) and four OHPMR frequencies (daily, each third day, weekly and solely at the end of experiment). The methane yields of barley, silage and slurry were compared with those from an automated volumetric method (AMPTS). Headspace volume and OHPMR frequency effects on biogas yield were mediated mainly through headspace pressure, with the latter having a negative effect on the biogas yield measured and relatively little effect on methane yield. Two mBMP treatments produced methane yields equivalent to AMPTS. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Rapid determination of the volatile components in tobacco by ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction with gas chromatography-mass spectrometry.

    PubMed

    Yang, Yanqin; Chu, Guohai; Zhou, Guojun; Jiang, Jian; Yuan, Kailong; Pan, Yuanjiang; Song, Zhiyu; Li, Zuguang; Xia, Qian; Lu, Xinbo; Xiao, Weiqiang

    2016-03-01

    An ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction was first employed to determine the volatile components in tobacco samples. The method combined the advantages of ultrasound, microwave, and headspace solid-phase microextraction. The extraction, separation, and enrichment were performed in a single step, which could greatly simplify the operation and reduce the whole pretreatment time. In the developed method, several experimental parameters, such as fiber type, ultrasound power, and irradiation time, were optimized to improve sampling efficiency. Under the optimal conditions, there were 37, 36, 34, and 36 components identified in tobacco from Guizhou, Hunan, Yunnan, and Zimbabwe, respectively, including esters, heterocycles, alkanes, ketones, terpenoids, acids, phenols, and alcohols. The compound types were roughly the same while the contents were varied from different origins due to the disparity of their growing conditions, such as soil, water, and climate. In addition, the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method was compared with the microwave-assisted extraction coupled to headspace solid-phase microextraction and headspace solid-phase microextraction methods. More types of volatile components were obtained by using the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction method, moreover, the contents were high. The results indicated that the ultrasound-microwave synergistic extraction coupled to headspace solid-phase microextraction technique was a simple, time-saving and highly efficient approach, which was especially suitable for analysis of the volatile components in tobacco. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Phytochemical study of the headspace volatile organic compounds of fresh algae and seagrass from the Adriatic Sea (single point collection)

    PubMed Central

    Marijanović, Zvonimir; Roje, Marin; Kuś, Piotr M.; Jokić, Stela; Čož-Rakovac, Rozelinda

    2018-01-01

    Performed phytochemical study contributes to the knowledge of volatile organic compounds (VOCs) of Halopteris filicina (Grateloup) Kützing, Dictyota dichotoma (Hudson) J. V. Lamouroux, Posidonia oceanica (L.) Delile and Flabellia petiolata (Turra) Nizamuddin from the Adriatic Sea (single point collection). VOCs were investigated by headspace solid-phase microextraction (HS-SPME) and analysed by gas chromatography and mass spectrometry (GC-MS/FID). H. filicina headspace contained dimethyl sulfide (DMS; 12.8%), C8-compounds (e.g. fucoserratene (I; 9.5%)), benzaldehyde (II; 8.7%), alkane C17, dictyopterene D and C (III, IV), tribromomethane (V), 1-iodopentane, others. F. petiolata headspace was characterized by DMS (22.2%), 6-methylhept-5-en-2-one (9.5%), C17 (9.1%), II (6.5%), compounds I-V. DMS (59.3%), C15 (14.5%), C17 (7.2%) and C19 (6.3%) dominated in P. oceanica headspace. Sesquiterpenes were found in D. dichotoma, predominantly germacrene D (28.3%) followed by other cadinenyl (abundant), muurolenyl and amorphenyl structures. Determined VOCs may be significant for chemosystematics and chemical communications in marine ecosystem. PMID:29738535

  7. Development of a syringe pump assisted dynamic headspace sampling technique for needle trap device.

    PubMed

    Eom, In-Yong; Niri, Vadoud H; Pawliszyn, Janusz

    2008-07-04

    This paper describes a new approach that combines needle trap devices (NTDs) with a dynamic headspace sampling technique (purge and trap) using a bidirectional syringe pump. The needle trap device is a 22-G stainless steel needle 3.5-in. long packed with divinylbenzene sorbent particles. The same sized needle, without packing, was used for purging purposes. We chose an aqueous mixture of benzene, toluene, ethylbenzene, and p-xylene (BTEX) and developed a sequential purge and trap (SPNT) method, in which sampling (trapping) and purging cycles were performed sequentially by the use of syringe pump with different distribution channels. In this technique, a certain volume (1 mL) of headspace was sequentially sampled using the needle trap; afterwards, the same volume of air was purged into the solution at a high flow rate. The proposed technique showed an effective extraction compared to the continuous purge and trap technique, with a minimal dilution effect. Method evaluation was also performed by obtaining the calibration graphs for aqueous BTEX solutions in the concentration range of 1-250 ng/mL. The developed technique was compared to the headspace solid-phase microextraction method for the analysis of aqueous BTEX samples. Detection limits as low as 1 ng/mL were obtained for BTEX by NTD-SPNT.

  8. Gram-negative and -positive bacteria differentiation in blood culture samples by headspace volatile compound analysis.

    PubMed

    Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören

    2016-12-01

    Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.

  9. Bromination of aromatic compounds by residual bromide in sodium chloride matrix modifier salt during heated headspace GC/MS analysis.

    PubMed

    Fine, Dennis D; Ko, Saebom; Huling, Scott

    2013-12-15

    Analytical artifacts attributed to the bromination of toluene, xylenes, and trimethylbenzenes were found during the heated headspace gas chromatography/mass spectrometry (GC/MS) analysis of aqueous samples. The aqueous samples were produced from Fenton-like chemical oxidation reactions and contained aromatic compounds, hydrogen peroxide (H2O2), and ferric sulfate. Prior to GC/MS headspace analysis, the samples were acidified (pH<2), and sodium chloride was amended to the headspace vial as a matrix modifier. The brominated artifacts were generated during heated headspace analysis. Further, when samples were spiked with a mixture of volatile chlorinated and aromatic compounds (50 µg/L), poor spike recoveries of toluene and xylenes occurred, and in some cases complete loss of trimethylbenzenes and naphthalene resulted. Where poor recovery of aromatic spike compounds occurred, brominated aromatic compounds were found. The only significant source of bromine in the reaction scheme is the bromide typically present (<0.01% w/w) in the sodium chloride amended to the samples. Conversely, brominated artifacts were absent when a buffered salt mixture composed of sodium chloride and potassium phosphate dibasic/monobasic was used as a matrix modifier and raised the sample pH (pH~6). This indicated that the brominated artifacts resulted from the reaction of the aromatic compounds with BrCl, which was formed by the reaction of H2O2, chloride, and bromide under acidic conditions. An alternative matrix modifier salt is recommended that prevents the bromination reaction and avoids these deleterious effects on sample integrity during headspace analysis. Published by Elsevier B.V.

  10. Determination of total acid content in biomass hydrolysates by solvent-assisted and reaction based headspace gas chromatography.

    PubMed

    Huang, Liu-Lian; Hu, Hui-Chao; Chen, Li-Hui

    2015-11-27

    This work reports on a novel method for the determination of total acid (TA) in biomass hydrolysates by a solvent-assisted and reaction-based headspace gas chromatography (HS-GC). The neutralization reaction between the acids in hydrolysates and bicarbonate in an ethanol (50%) aqueous solution was performed in a closed headspace sample vial, from which the carbon dioxide generated from the reaction was detected by HS-GC. It was found that the addition of ethanol can effectively eliminate the precipitation of some organic acids in the biomass hydrolysates. The results showed that the reaction and headspace equilibration can be achieved within 45min at 70°C; the method has a good precision (RSD<3.27%) and accuracy (recovery of 97.4-105%); the limit of quantification is 1.36μmol. The present method is quite suitable to batch analysis of TA content in hydrolysate for the biorefinery related research. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Measurement of gas-liquid partition coefficient and headspace concentration profiles of perfume materials by solid-phase microextraction and capillary gas chromatography-mass spectrometry

    PubMed

    Liu; Wene

    2000-09-01

    An empirical model describing the relationship between the partition coefficients (K) of perfume materials in the solid-phase microextraction (SPME) fiber stationary phase and the Linearly Temperature Programmed Retention Index (LTPRI) is obtained. This is established using a mixture of eleven selected fragrance materials spiked in mineral oil at different concentration levels to simulate liquid laundry detergent matrices. Headspace concentrations of the materials are measured using both static headspace and SPME-gas chromatography analysis. The empirical model is tested by measuring the K values for fourteen perfume materials experimentally. Three of the calculated K values are within 2-19% of the measured K value, and the other eleven calculated K values are within 22-59%. This range of deviation is understandable because a diverse mixture was used to cover most chemical functionalities in order to make the model generally applicable. Better prediction accuracy is expected when a model is established using a specific category of compounds, such as hydrocarbons or aromatics. The use of this method to estimate distribution constants of fragrance materials in liquid matrices is demonstrated. The headspace SPME using the established relationship between the gas-liquid partition coefficient and the LTPRI is applied to measure the headspace concentration of fragrances. It is demonstrated that this approach can be used to monitor the headspace perfume profiles over consumer laundry and cleaning products. This method can provide high sample throughput, reproducibility, simplicity, and accuracy for many applications for screening major fragrance materials over consumer products. The approach demonstrated here can be used to translate headspace SPME results into true static headspace concentration profiles. This translation is critical for obtaining the gas-phase composition by correcting for the inherent differential partitioning of analytes into the fiber stationary

  12. Low-temperature headspace-trap gas chromatography with mass spectrometry for the determination of trace volatile compounds from the fruit of Lycium barbarum L.

    PubMed

    Chen, Fangjiao; Su, Yue; Zhang, Fang; Guo, Yinlong

    2015-02-01

    The total saccharides content of Lycium barbarum L. is very high, and a high temperature would result in saccharide decomposition and the emergence of a large amount of water. Moreover, the volatile compounds from the fruit of L. barbarum L. are rather low in concentration. Hence, it is difficult for a conventional headspace method to study the volatile compounds from the fruit of L. barbarum L. Since headspace-trap gas chromatography with mass spectrometry is an excellent method for trace analysis, a headspace-trap gas chromatography with mass spectrometry method based on low-temperature (30°C) enrichment and multiple headspace extraction was developed to explore the volatile compounds from the fruit of L. barbarum L. The headspace of the sample was extracted in 17 cycles at 30°C. Each time, the compounds extracted were concentrated in the trap (Tenax TA and Tenax GR, 1:1). Finally, all the volatile compounds were delivered into the gas chromatograph after thermal desorption. With the method described above, a total of 57 compounds were identified. The identification was completed by mass spectral search, retention index, and accurate mass measurement. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Effect of headspace mixing in static chambers and sampling protocol on calculated CH4 fluxes from soils

    NASA Astrophysics Data System (ADS)

    Juszczak, R.; Pihlatie, M.; Christiansen, J. R.; Giebels, M.; Schreiber, P.; Aaltonen, H.; Korhonen, J.; Rasilo, T.; Chojnicki, B. H.; Urbaniak, M.

    2009-04-01

    Closed static chambers are often used for greenhouse gas flux measurements from soils. The type of chamber, chamber handling and sampling protocol can influence the measurements. In most cases the calculated fluxes are suspected to be underestimated mainly because of reduction of gas diffusion from the soil to chamber headspace due to changed trace gas concentration gradient. Thus, fans are often applied to obtain better mixing of the air inside the chamber headspace and in turn reduce the negative effect of decreased concentration gradient. The open question is, however, to which extent the fluxes are changed by fans and whether they still remain underestimated or may even be overestimated? On the other hand, different sampling protocols are used assuming that they do not affect the flux measurements. To test different types of static chambers and different sampling procedures applied for measurement of greenhouse gas (CH4 and N2O) fluxes a chamber calibration campaign was organized at Hyytiälä Forestry Field Station in Southern Finland during August-October 2008. The main aim of the campaign was to quantitatively assess the uncertaintities and errors related to static chamber measurements. During this campaign static chambers were tested for 5 different CH4 and N2O flux levels with 3 different soil conditions (moisture and porosity) in a calibration tank described by Pumpanen et al. (2004). Among the different experiments, several special tests were carried out with the closed static chambers. Here, results of two special tests are presented to document whether 1) the air mixing inside the chamber headspace, 2) different sampling procedures influence the CH4 fluxes, and 3) how different calculation methods lead to varying results. Two static chambers of different volumes (65.5 and 195 liters) but with the same circular shape and surface area were connected to a LOS GATOS fats methane analyzer. The CH4 concentration inside the chamber headspace was monitored

  14. Determination of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution by reaction-based headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan

    2018-04-01

    We report on a headspace gas chromatographic method for determining the content of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution. It was based on quantitatively converting 3-chloro-1,2-propanediol to formaldehyde by periodate oxidation in a closed headspace sample vial at a room temperature for 10 min, and then to methanol by borohydride reduction at 90°C for 40 min followed by the headspace gas chromatographic measurement. The results showed that the present method has an excellent measurement precision (relative standard deviation < 2.60%) and accuracy (recoveries from 96.4-102%) in 3-chloro-1,2-propanediol analysis. The limit of quantitation was 0.031 mg/mL. It is simple and suitable for determining the 3-chloro-1,2-propanediol content in polyamideamine epichlorohydrin resin solution. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Identifying and Determining Halocarbons in Water Using Headspace Gas Chromatography.

    DTIC Science & Technology

    1981-10-01

    chromatography Halogenated hydrocarbons , / Wastewater 26. T -ACT C’Cth.I .- ,,ee .- ,ncee, ,Id ntify y block number) --/,*Since the discovery that...USING HEADSPACE GAS CHROMATOGRAPHY Daniel C. Leggett INTRODUCTION Chlorination is a well-established method of disinfecting water for drinking and of... disinfecting municipal wastewater prior to disposal. The recent discovery that persistent chloro-organic molecules are formed in this processi 5 has

  16. Vented spikes improve delivery from intravenous bags with no air headspace.

    PubMed

    Galush, William J; Horst, Travis A

    2015-07-01

    Flexible plastic bags are the container of choice for most intravenous (i.v.) infusions. Under certain circumstances, however, the air-liquid interface present in these i.v. bags can lead to physical instability of protein biopharmaceuticals, resulting in product aggregation. In principle, the air headspace present in the bags can be removed to increase drug stability, but experiments described here show that this can result in incomplete draining of solution from the bag using gravity delivery, or generation of negative pressure in the bag when an infusion pump is used. It is expected that these issues could lead to incomplete delivery of medication to patients or pump-related problems, respectively. However, here it is shown that contrary to the standard pharmacy practice of using nonvented spikes with i.v. bags, the use of vented spikes with i.v. bags that lack air headspace allows complete delivery of the dose solution without impacting the physical stability of a protein-based drug. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  17. Determination of the solubility of inorganic salts by headspace gas chromatography.

    PubMed

    Chai, X S; Zhu, J Y

    2003-05-09

    This work reports a novel method for determination of salt solubility using headspace gas chromatography. A very small amount of volatile compound (such as methanol) is added in the studied solution. Due to the molecular interaction in the solution, the vapor-liquid equilibrium (VLE) partitioning coefficient of the volatile species will change with different salt contents in the solution. Therefore, the concentration of volatile species in the vapor phase is proportional to the salt concentration in the liquid phase, which can be easily determined by headspace gas chromatography. Until the salt concentration in the solution is saturated, the concentration of volatile compound in the vapor phase will continue to increase further and a breakpoint will appear on the VLE curve. The solubility of the salts can be determined by the identification of the breakpoint. It was found that the measured solubility of sodium carbonate and sodium sulfate in aqueous solutions is slightly higher (about 6-7%) than those reported in the literature method. The present method can be easily applied to industrial solution systems.

  18. Determination of Porosity in Shale by Double Headspace Extraction GC Analysis.

    PubMed

    Zhang, Chun-Yun; Li, Teng-Fei; Chai, Xin-Sheng; Xiao, Xian-Ming; Barnes, Donald

    2015-11-03

    This paper reports on a novel method for the rapid determination of the shale porosity by double headspace extraction gas chromatography (DHE-GC). Ground core samples of shale were placed into headspace vials and DHE-GC measurements of released methane gas were performed at a given time interval. A linear correlation between shale porosity and the ratio of consecutive GC signals was established both theoretically and experimentally by comparing with the results from the standard helium pycnometry method. The results showed that (a) the porosity of ground core samples of shale can be measured within 30 min; (b) the new method is not significantly affected by particle size of the sample; (c) the uncertainties of measured porosities of nine shale samples by the present method range from 0.31 to 0.46 p.u.; and (d) the results obtained by the DHE-GC method are in a good agreement with those from the standard helium pycnometry method. In short, the new DHE-GC method is simple, rapid, and accurate, making it a valuable tool for shale gas-related research and applications.

  19. Australian young people's awareness of headspace, beyondblue and other mental health organizations.

    PubMed

    Jorm, Anthony F

    2009-12-01

    Objective: The aim of this paper is to assess young people's awareness of mental health organizations supporting their age group. Of particular interest was awareness of headspace, which was created in 2006 to provide youth-oriented mental health services, and of beyondblue, which aims to raise community awareness of depression, anxiety and related disorders. Method: A telephone survey was carried out on a national sample of young people who were part of a 2-year follow-up study of youth mental health literacy. Data were analysed for those aged 13-25 years. Results: Awareness was highest for beyondblue and telephone helplines; headspace had established some awareness, particularly in areas where its services operate. However, awareness was unrelated to the participant's psychological symptoms in the past year. Conclusions: If youth-oriented services are to be successful, young people need to know about them. Awareness campaigns need to be targeted at the sub-group who have greatest need for these services, namely those with mental health problems.

  20. Determination of carboxyl groups in wood fibers by headspace gas chromatography

    Treesearch

    X.-S. Chai; Q.X. Hou; J.Y. Zhu; S.-L. Chen; S.F. Wang; L. Lucia

    2003-01-01

    The phase reaction conversion (PRC) headspace gas chromatographic (HSGC) technique was employed to develop a method for the determination of the content of carboxyl groups in wood fibers. Acid treatment of the wood fibers using hydrochloric was applied to convert carboxyl groups to carboxyl acids. Bicarbonate solution is then used to react with carboxyl acids on the...

  1. Simultaneous Determination of Benzene and Toluene in Pesticide Emulsifiable Concentrate by Headspace GC-MS

    PubMed Central

    Jiang, Hua; Yang, Jing; Fan, Li; Li, Fengmin; Huang, Qiliang

    2013-01-01

    The toxic inert ingredients in pesticide formulations are strictly regulated in many countries. In this paper, a simple and efficient headspace-gas chromatography-mass spectrometry (HSGC-MS) method using fluorobenzene as an internal standard (IS) for rapid simultaneous determination of benzene and toluene in pesticide emulsifiable concentrate (EC) was established. The headspace and GC-MS conditions were investigated and developed. A nonpolar fused silica Rtx-5 capillary column (30 m × 0.20 mm i.d. and 0.25 μm film thickness) with temperature programming was used. Under optimized headspace conditions, equilibration temperature of 120°C, equilibration time of 5 min, and sample size of 50 μL, the regression of the peak area ratios of benzene and toluene to IS on the concentrations of analytes fitted a linear relationship well at the concentration levels ranging from 3.2 g/L to 16.0 g/L. Standard additions of benzene and toluene to blank different matrix solutions 1ead to recoveries of 100.1%–109.5% with a relative standard deviation (RSD) of 0.3%–8.1%. The method presented here stands out as simple and easily applicable, which provides a way for the determination of toxic volatile adjuvant in liquid pesticide formulations. PMID:23607048

  2. [Determination of olive oil content in olive blend oil by headspace gas chromatography-mass spectrometry].

    PubMed

    Jiang, Wanfeng; Zhang, Ning; Zhang, Fengyan; Yang, Zhao

    2017-07-08

    A method for the determination of the content of olive oil in olive blend oil by headspace gas chromatography-mass spectrometry (SH-GC/MS) was established. The amount of the sample, the heating temperature, the heating time, the amount of injection, the injection mode and the chromatographic column were optimized. The characteristic compounds of olive oil were found by chemometric method. A sample of 1.0 g was placed in a 20 mL headspace flask, and heated at 180℃ for 2700 s. Then, 1.0 mL headspace gas was taken into the instrument. An HP-88 chromatographic column was used for the separation and the analysis was performed by GC/MS. The results showed that the linear range was 0-100%(olive oil content). The linear correlation coefficient ( r 2 ) was more than 0.995, and the limits of detection were 1.26%-2.13%. The deviations of olive oil contents in the olive blend oil were from -0.65% to 1.02%, with the relative deviations from -1.3% to 6.8% and the relative standard deviations from 1.18% to 4.26% ( n =6). The method is simple, rapid, environment friendly, sensitive and accurate. It is suitable for the determination of the content of olive oil in olive blend oil.

  3. Understanding the role of saliva in aroma release from wine by using static and dynamic headspace conditions.

    PubMed

    Muñoz-González, Carolina; Feron, Gilles; Guichard, Elisabeth; Rodríguez-Bencomo, J José; Martín-Álvarez, Pedro J; Moreno-Arribas, M Victoria; Pozo-Bayón, M Ángeles

    2014-08-20

    The aim of this work was to determine the role of saliva in wine aroma release by using static and dynamic headspace conditions. In the latter conditions, two different sampling points (t = 0 and t = 10 min) corresponding with oral (25.5 °C) and postoral phases (36 °C) were monitored. Both methodologies were applied to reconstituted dearomatized white and red wines with different nonvolatile wine matrix compositions and a synthetic wine (without matrix effect). All of the wines had the same ethanol concentration and were spiked with a mixture of 45 aroma compounds covering a wide range of physicochemical characteristics at typical wine concentrations. Two types of saliva (human and artificial) or control samples (water) were added to the wines. The adequacy of the two headspace methodologies for the purposes of the study (repeatability, linear ranges, determination coefficients, etc.) was previously determined. After application of different chemometric analysis (ANOVA, LSD, PCA), results showed a significant effect of saliva on aroma release dependent on saliva type (differences between artificial and human) and on wine matrix using static headspace conditions. Red wines were more affected than white and synthetic wines by saliva, specifically human saliva, which provoked a reduction in aroma release for most of the assayed aroma compounds independent of their chemical structure. The application of dynamic headspace conditions using a saliva bioreactor at the two different sampling points (t = 0 and t = 10 min) showed a lesser but significant effect of saliva than matrix composition and a high influence of temperature (oral and postoral phases) on aroma release.

  4. Influence of headspace flushing on methane production in Biochemical Methane Potential (BMP) tests.

    PubMed

    Koch, Konrad; Bajón Fernández, Yadira; Drewes, Jörg E

    2015-06-01

    The influence of headspace flushing on the specific methane (CH4) production of blank samples with just inoculum in Biochemical Methane Potential (BMP) tests was studied. The three most common ways were applied: flushing with nitrogen (N2) gas, flushing with a mixture of N2 and CO2 (80/20 v/v), and no flushing. The results revealed that removing the oxygen is crucial to avoid aerobic respiration, which caused both hindered activity of methanogens and loss of methane potential. Furthermore it was demonstrated that 20% of CO2 in the flush gas increased significantly the methane production by over 20% compared to the flushing with pure N2. In order to mimic the same headspace conditions as in full-scale treatment plants, using a flush gas with a similar CO2 concentration as the expected biogas is suggested. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Counting cell number in situ by quantification of dimethyl sulphide in culture headspace.

    PubMed

    Chippendale, Thomas W E; Španěl, Patrik; Smith, David; El Haj, Alicia J

    2014-10-07

    A novel, non-invasive technique is reported for determining the numbers of cells in a culture by quantifying dimethyl sulphide (DMS) in the culture headspace as produced by the cellular enzymatic reduction of dissolved dimethyl sulphoxide (DMSO). Measured DMS concentrations, as performed using selected ion flow tube mass spectrometry (SIFT-MS), in the headspace of 2D and 3D cultures of four cell lines, viz. HEK293 (kidney), MG63 (bone), hepG2 (liver) and CALU-1 (lung), linearly correlate with starting cell number. Clear differences in the rates of production of DMS by the four cell types in both the 2D and 3D situations are seen. This novel analytical technique for cell enumeration offers a significant contribution to quality assessment across cell-based research and industry, including analysis of large scale culture systems, and for routine cell biology research.

  6. Headspace theater: an innovative method for experiential learning of psychiatric symptomatology using modified role-playing and improvisational theater techniques.

    PubMed

    Ballon, Bruce C; Silver, Ivan; Fidler, Donald

    2007-01-01

    Headspace Theater has been developed to allow small group learning of psychiatric conditions by creating role-play situations in which participants are placed in a scenario that simulates the experience of the condition. The authors conducted a literature review of role-playing techniques, interactive teaching, and experiential education, and performed consultations with experts in improvisational theater, live-action role-playing, and cognitive psychology (constructivism). Participants have universally rated the Headspace Theater experience positively. They affirmed that the simulations evoke emotions and cognitive distortions that create a window into the experience of a patient suffering from psychiatric symptoms. Several participants have also disseminated the techniques and scenarios to their local teaching setting. Headspace Theater may serve as a useful tool for helping various learners to experientially understand what a person may encounter when under the influence of a mental health condition, and thus help shape attitudes and increase empathy toward such people.

  7. Olive Oil Headspace Characterization by a Gas Sensor Array

    NASA Astrophysics Data System (ADS)

    Santonico, Marco; Gianni, Giacomo; Capuano, Rosamaria; Migliorini, Marzia; Catini, Alexandro; Dini, Francesca; Martinelli, Eugenio; Paolesse, Roberto; D'Amico, Arnaldo; Di Natale, Corrado

    2011-09-01

    Olive oil quality is strictly correlated to the volatile compounds profile. Both quality and defects can be connected to the presence of specific volatile compounds in the oil headspace. In this paper, olive oil samples have been artificially modified by adding a number of compounds known to be typical of the more frequent defects: fusty, musty, muddy and rancid. Results demonstrate the sensitivity of the electronic nose to the compounds characterizing the defects and then the capability of the instrument to identify the defects in real samples.

  8. Determination of sulfur dioxide in wine using headspace gas chromatography and electron capture detection.

    PubMed

    Aberl, A; Coelhan, M

    2013-01-01

    Sulfites are routinely added as preservatives and antioxidants in wine production. By law, the total sulfur dioxide content in wine is restricted and therefore must be monitored. Currently, the method of choice for determining the total content of sulfur dioxide in wine is the optimised Monier-Williams method, which is time consuming and laborious. The headspace gas chromatographic method described in this study offers a fast and reliable alternative method for the detection and quantification of the sulfur dioxide content in wine. The analysis was performed using an automatic headspace injection sampler, coupled with a gas chromatograph and an electron capture detector. The method is based on the formation of gaseous sulfur dioxide subsequent to acidification and heating of the sample. In addition to free sulfur dioxide, reversibly bound sulfur dioxide in carbonyl compounds, such as acetaldehyde, was also measured with this method. A total of 20 wine samples produced using diverse grape varieties and vintages of varied provenance were analysed using the new method. For reference and comparison purposes, 10 of the results obtained by the proposed method were compared with those acquired by the optimised Monier-Williams method. Overall, the results from the headspace analysis showed good correlation (R = 0.9985) when compared with the conventional method. This new method requires minimal sample preparation and is simple to perform, and the analysis can also be completed within a short period of time.

  9. Determination of isocyanate groups in the organic intermediates by reaction-based headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-10-14

    This work reports on a novel method for the determination of isocyanate groups in the related organic intermediates by a reaction-based headspace gas chromatography. The method is based on measuring the CO 2 formed from the reaction between the isocyanate groups in the organic intermediates and water in a closed headspace sample vial at 45°C for 20min. The results showed that the method has a good precision and accuracy, in which the relative standard deviation in the repeatability measurement was 5.26%, and the relative differences between the data obtained by the HS-GC method and the reference back-titration method were within 9.42%. The present method is simple and efficient and is particularly suitable to be used for determining the isocyanate groups in the batch sample analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Application of headspace analysis to the study of sorption of hydrophobic organic chemicals to α-Al2O3

    USGS Publications Warehouse

    Pelinger, Judith A.; Eisenreich, Steven J.; Capel, Paul D.

    1993-01-01

    The sorption of hydrophobic organic chemicals (HOCs) to ??-Al2O3 was investigated with a headspace analysis method. The semiautomated headspace analyzer gave rapid, precise, and accurate results for a homologous series alkylbenzenes even at low percentages of solute mass sorbed (3-50%). Sorption experiments carried out with benzene alone indicated weak interactions with well-characterized aluminum oxide, and a solids concentration effect was observed. When the sorption coefficients for benzene alone obtained by headspace analysis were extrapolated up to the solids concentrations typically used in batch sorption experiments, the measured sorption coefficients agreed with reported sorption coefficients for HOCs and sediments of low fractional organic carbon content. Sorbed concentrations increased exponentially with aqueous concentration in isotherms with mixtures of alkylbenzenes, indicating solute-solute interactions at the mineral surface. Sorption was, however, greater than predicted for partitioning of a solute between its pure liquid phase and water, indicating additional influences of the surface and/or the structured liquid near the mineral surface. ?? 1993 American Chemical Society.

  11. Determination of volatile marker compounds in raw ham using headspace-trap gas chromatography.

    PubMed

    Bosse Née Danz, Ramona; Wirth, Melanie; Konstanz, Annette; Becker, Thomas; Weiss, Jochen; Gibis, Monika

    2017-03-15

    A simple, reliable and automated method was developed and optimized for qualification and quantification of aroma-relevant volatile marker compounds of North European raw ham using a headspace (HS)-Trap gas chromatography-mass spectrometry (GC-MS) and GC-flame ionization detector (FID) analysis. A total of 38 volatile compounds were detected with this HS-Trap GC-MS method amongst which the largest groups were ketones (12), alcohols (8), hydrocarbons (7), aldehydes (6) and esters (3). The HS-Trap GC-FID method was optimized for the parameters: thermostatting time and temperature, vial and desorption pressure, number of extraction cycles and salt addition. A validation for 13 volatile marker compounds with limits of detection in ng/g was carried out. The optimized method can serve as alternative to conventional headspace and solid phase micro extraction methods and allows users to determine volatile compounds in raw hams making it of interest to industrial and academic meat scientists. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. A simple headspace equilibration method for measuring dissolved methane

    USGS Publications Warehouse

    Magen, C; Lapham, L.L.; Pohlman, John W.; Marshall, Kristin N.; Bosman, S.; Casso, Michael; Chanton, J.P.

    2014-01-01

    Dissolved methane concentrations in the ocean are close to equilibrium with the atmosphere. Because methane is only sparingly soluble in seawater, measuring it without contamination is challenging for samples collected and processed in the presence of air. Several methods for analyzing dissolved methane are described in the literature, yet none has conducted a thorough assessment of the method yield, contamination issues during collection, transport and storage, and the effect of temperature changes and preservative. Previous extraction methods transfer methane from water to gas by either a "sparge and trap" or a "headspace equilibration" technique. The gas is then analyzed for methane by gas chromatography. Here, we revisit the headspace equilibration technique and describe a simple, inexpensive, and reliable method to measure methane in fresh and seawater, regardless of concentration. Within the range of concentrations typically found in surface seawaters (2-1000 nmol L-1), the yield of the method nears 100% of what is expected from solubility calculation following the addition of known amount of methane. In addition to being sensitive (detection limit of 0.1 ppmv, or 0.74 nmol L-1), this method requires less than 10 min per sample, and does not use highly toxic chemicals. It can be conducted with minimum materials and does not require the use of a gas chromatograph at the collection site. It can therefore be used in various remote working environments and conditions.

  13. Rapid analysis of ultraviolet filters using dispersive liquid-liquid microextraction coupled to headspace gas chromatography and mass spectrometry.

    PubMed

    Pierson, Stephen A; Trujillo-Rodríguez, María J; Anderson, Jared L

    2018-05-29

    An ionic-liquid-based in situ dispersive liquid-liquid microextraction method coupled to headspace gas chromatography and mass spectrometry was developed for the rapid analysis of ultraviolet filters. The chemical structures of five ionic liquids were specifically designed to incorporate various functional groups for the favorable extraction of the target analytes. Extraction parameters including ionic liquid mass, molar ratio of ionic liquid to metathesis reagent, vortex time, ionic strength, pH, and total sample volume were studied and optimized. The effect of the headspace temperature and volume during the headspace sampling step was also evaluated to increase the sensitivity of the method. The optimized procedure is fast as it only required ∼7-10 min per extraction and allowed for multiple extractions to be performed simultaneously. In addition, the method exhibited high precision, good linearity, and low limits of detection for six ultraviolet filters in aqueous samples. The developed method was applied to both pool and lake water samples attaining acceptable relative recovery values. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Analysis of ammonium nitrate headspace by on-fiber solid phase microextraction derivatization with gas chromatography mass spectrometry.

    PubMed

    Lubrano, Adam L; Andrews, Benjamin; Hammond, Mark; Collins, Greg E; Rose-Pehrsson, Susan

    2016-01-15

    A novel analytical method has been developed for the quantitation of trace levels of ammonia in the headspace of ammonium nitrate (AN) using derivatized solid phase microextraction (SPME) fibers with gas chromatography mass spectrometry (GC-MS). Ammonia is difficult to detect via direct injection into a GC-MS because of its low molecular weight and extreme polarity. To circumvent this issue, ammonia was derivatized directly onto a SPME fiber by the reaction of butyl chloroformate coated fibers with the ammonia to form butyl carbamate. A derivatized externally sampled internal standard (dESIS) method based upon the reactivity of diethylamine with unreacted butyl chloroformate on the SPME fiber to form butyl diethylcarbamate was established for the reproducible quantification of ammonia concentration. Both of these compounds are easily detectable and separable via GC-MS. The optimized method was then used to quantitate the vapor concentration of ammonia in the headspace of two commonly used improvised explosive device (IED) materials, ammonium nitrate fuel oil (ANFO) and ammonium nitrate aluminum powder (Ammonal), as well as identify the presence of additional fuel components within the headspace. Published by Elsevier B.V.

  15. Influence of polydimethylsiloxane outer coating and packing material on analyte recovery in dual-phase headspace sorptive extraction.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Sgorbini, Barbara; David, Frank; Sandra, Pat; Rubiolo, Patrizia

    2007-09-14

    Dual phase twisters (DP twisters), consisting of a polydimethylsiloxane (PDMS) outer coating and a second complementary (ad)sorbent as inner packing, have recently been shown to extend the applicability of headspace sorptive extraction (HSSE). In comparison to HSSE using PDMS only, the recovery of analytes from the headspace of a solid or liquid matrix is increased by combining the concentration capabilities of two sampling materials operating on different mechanisms (sorption and adsorption). This study compares the performance of DP twisters consisting of different PDMS outer coatings and different packing materials, including Tenax GC, a bisphenol-PDMS copolymer, Carbopack coated with 5% of Carbowax and beta-cyclodextrin, for the analysis of the headspace of roasted Arabica coffee, dried sage leaves and an aqueous test mixture containing compounds with different water solubility, acidity, polarity and volatility as test samples. In general, DP twisters showed a higher concentration capability than the corresponding conventional PDMS twisters for the analytes considered. The highest recoveries were obtained with DP twisters consisting of 0.2mm thick PDMS coating combined with Tenax GC, a bisphenol-PDMS copolymer and Carbopack coated with 5% of Carbowax as inner adsorption phase.

  16. Zero-Headspace Coal-Core Gas Desorption Canister, Revised Desorption Data Analysis Spreadsheets and a Dry Canister Heating System

    USGS Publications Warehouse

    Barker, Charles E.; Dallegge, Todd A.

    2005-01-01

    Coal desorption techniques typically use the U.S. Bureau of Mines (USBM) canister-desorption method as described by Diamond and Levine (1981), Close and Erwin (1989), Ryan and Dawson (1993), McLennan and others (1994), Mavor and Nelson (1997) and Diamond and Schatzel (1998). However, the coal desorption canister designs historically used with this method have an inherent flaw that allows a significant gas-filled headspace bubble to remain in the canister that later has to be compensated for by correcting the measured desorbed gas volume with a mathematical headspace volume correction (McLennan and others, 1994; Mavor and Nelson, 1997).

  17. Use of ionic liquids as headspace gas chromatography diluents for the analysis of residual solvents in pharmaceuticals.

    PubMed

    Nacham, Omprakash; Ho, Tien D; Anderson, Jared L; Webster, Gregory K

    2017-10-25

    In this study, two ionic liquids (ILs), 1-butyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ([BMIM][NTf 2 ]) and trihexyltetradecylphosphonium bis[(trifluoromethyl)sulfonyl]imide ([P 66614 ][NTf 2 ]) were examined as contemporary diluents for residual solvent analysis using static headspace gas chromatography (SHS-GC) coupled with flame ionization detection (FID). ILs are a class of non-molecular solvents featuring negligible vapor pressure and high thermal stabilities. Owing to these favorable properties, ILs have potential to enable superior sensitivity and reduced interference, compared to conventional organic diluents, at high headspace incubation temperatures. By employing the [BMIM][NTf 2 ] IL as a diluent, a 25-fold improvement in limit of detection (LOD) was observed with respect to traditional HS-GC diluents, such as N-methylpyrrolidone (NMP). The established IL-based method demonstrated LODs ranging from 5.8 parts-per-million (ppm) to 20ppm of residual solvents in drug substances. The optimization of headspace extraction conditions was performed prior to method validation. An incubation temperature of 140°C and a 15min incubation time provided the best sensitivity for the analysis. Under optimized experimental conditions, the mass of residual solvents partitioned in the headspace was higher when using [BMIM][NTf 2 ] than NMP as a diluent. The analytical performance was demonstrated by determining the repeatability, accuracy, and linearity of the method. Linear ranges of up to two orders of magnitude were obtained for class 3 solvents. Excellent analyte recoveries were obtained in the presence of three different active pharmaceutical ingredients. Owing to its robustness, high throughput, and superior sensitivity, the HS-GC IL-based method can be used as an alternative to existing residual solvent methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. [Determination of residual acetone in soybean phospholipids by headspace gas chromatography].

    PubMed

    Shen, S C; Zhang, W B; Cui, L X

    2000-11-01

    Soybean phospholipids have many functions and alimentary actions. In our country, powder soybean phospholipids are generally got by extraction with acetone, followed by vacuum drying. There may be some residual acetone present in the soybean phospholipids, which is harmful to health. So, we must know residual acetone content in the soybean phospholipids. However we have not found a method to determine the residual acetone in the soybean phospholipids. In this paper, headspace GC was used to determine residual acetone in powder soybean phospholipids. The headspace bottle was glass with a volume of 15 milliliters. Certain amounts of water, ammonium sulfate, and sample were added into the bottle. The mixture was made into a brei as soon as possible. The bottle was put into a water bath at 40 degrees C for an hour. The GC column was a 2 m x 3 mm i.d. stainless steel tube packed with GDX-103 stationary phase. Temperatures of both injector and detector were kept at 120 degrees C. Column temperature was 160 degrees C. Injection volume was 1 mL. External standard method was used for quantitation. The RSD was 1.2%. The recoveries in the range of 25.0 micrograms/g-100 micrograms/g were 98.4%-104%.

  19. Impact of phase ratio, polydimethylsiloxane volume and size, and sampling temperature and time on headspace sorptive extraction recovery of some volatile compounds in the essential oil field.

    PubMed

    Bicchi, Carlo; Cordero, Chiara; Liberto, Erica; Rubiolo, Patrizia; Sgorbini, Barbara; Sandra, Pat

    2005-04-15

    This study evaluates concentration capability of headspace sorptive extraction (HSSE) and the influence of sampling conditions on HSSE recovery of an analyte. A standard mixture in water of six high-to-medium volatility analytes (isobutyl methyl ketone, 3-hexanol, isoamyl acetate, 1,8-cineole, linalool and carvone) was used to sample the headspace by HSSE with stir bars coated with different polydimethylsiloxane (PDMS) volumes (20, 40, 55 and 110 microL, respectively), headspace vial volumes (8, 21.2, 40, 250 and 1000 mL), sampling temperatures (25, 50 and 75 degrees C) and sampling times (30, 60 and 120 min, and 4, 8 and 16 h). The concentration factors (CFs) of HSSE versus static headspace (S-HS) were also determined. Analytes sampled by the PDMS stir bars were recovered by thermal desorption (TDS) and analysed by capillary GC-MS. This study demonstrates how analyte recovery depends on its physico-chemical characteristics and affinity for PDMS (octanol-water partition coefficients), sampling temperatures (50 degrees C) and times (60 min), the volumes of headspace (40 mL) and of PDMS (in particular, for high volatility analytes). HSSE is also shown to be very effective for trace analysis. The HSSE CFs calculated versus S-HS with a 1000 mL headspace volumes at 25 degrees C during 4 h sampling ranged between 10(3) and 10(4) times for all analytes investigated while the limits of quantitation determined under the same conditions were in the nmol/L range.

  20. A novel headspace gas chromatographic method for in situ monitoring of monomer conversion during polymerization in an emulsion environment.

    PubMed

    Chai, Xin-Sheng; Zhong, Jin-Feng; Hu, Hui-Chao

    2012-05-18

    This paper describes a novel multiple-headspace extraction/gas chromatographic (MHE-GC) technique for monitoring monomer conversion during a polymerization reaction in a water-based emulsion environment. The polymerization reaction of methyl methacrylate (MMA) in an aqueous emulsion is used as an example. The reaction was performed in a closed headspace sample vial (as a mini-reactor), with pentane as a tracer. In situ monitoring of the vapor concentration of the tracer, employing a multiple headspace extraction (sampling) scheme, coupled to a GC, makes it possible to quantitatively follow the conversion of MMA during the early stages of polymerization. Data on the integrated amount of the tracer vapor released from the monomer droplet phase during the polymerization is described by a mathematic equation from which the monomer conversion can be calculated. The present method is simple, automated and economical, and provides an efficient tool in the investigation of the reaction kinetics and effects of the reaction conditions on the early stage of polymerization. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Determination of dichloroacetic acid and trichloroacetic acid in drinking water by acidic methanol esterification and headspace gas chromatography.

    PubMed

    Wang, Y H; Wong, P K

    2005-05-01

    A simple and rapid headspace method for gas chromatographic determination of dichloroacetic acid (DCAA) and trichloroacetic acid (TCAA) in drinking water was developed. Acidic methanol esterification followed by a headspace technique using a capillary column gas chromatograph (GC) equipped with an electron capture detector (ECD) was applied to determine the levels of DCAA and TCAA in drinking water. The major advantages of this method are the use of acidic methanol as the derivatization agent instead of the hazardous diazomethane, and esterification is carried out in water instead of organic solvent. DCAA and TCAA methyl esters produced in the reaction were determined directly by a headspace GC/ECD method. The linear correlation coefficients at concentrations ranging from 0 to 60 microg/L were 0.992 and 0.996 for DCAA and TCAA, respectively. The relative standard deviations (RSD, %) for the determination of DCAA and TCAA in drinking water were 15 and 21.3%, respectively (n=3). The detection limits of this method were 3 and 0.5 microg/L for DCAA and TCAA, respectively, and the recovery was 68-103.2% for DCAA and TCAA.

  2. Effects of gas composition in headspace and bicarbonate concentrations in media on gas and methane production, degradability, and rumen fermentation using in vitro gas production techniques.

    PubMed

    Patra, Amlan Kumar; Yu, Zhongtang

    2013-07-01

    Headspace gas composition and bicarbonate concentrations in media can affect methane production and other characteristics of rumen fermentation in in vitro gas production systems, but these 2 important factors have not been evaluated systematically. In this study, these 2 factors were investigated with respect to gas and methane production, in vitro digestibility of feed substrate, and volatile fatty acid (VFA) profile using in vitro gas production techniques. Three headspace gas compositions (N2+ CO2+ H2 in the ratio of 90:5:5, CO2, and N2) with 2 substrate types (alfalfa hay only, and alfalfa hay and a concentrate mixture in a 50:50 ratio) in a 3×2 factorial design (experiment 1) and 3 headspace compositions (N2, N2 + CO2 in a 50:50 ratio, and CO2) with 3 bicarbonate concentrations (80, 100, and 120 mM) in a 3×3 factorial design (experiment 2) were evaluated. In experiment 1, total gas production (TGP) and net gas production (NGP) was the lowest for CO2, followed by N2, and then the gas mixture. Methane concentration in headspace gas after fermentation was greater for CO2 than for N2 and the gas mixture, whereas total methane production (TMP) and net methane production (NMP) were the greatest for CO2, followed by the gas mixture, and then N2. Headspace composition did not affect in vitro digestibility or the VFA profile, except molar percentages of propionate, which were greater for CO2 and N2 than for the gas mixture. Methane concentration in headspace gas, TGP, and NGP were affected by the interaction of headspace gas composition and substrate type. In experiment 2, increasing concentrations of CO2 in the headspace decreased TGP and NGP quadratically, but increased the concentrations of methane, NMP, and in vitro fiber digestibility linearly, and TMP quadratically. Fiber digestibility, TGP, and NGP increased linearly with increasing bicarbonate concentrations in the medium. Concentrations of methane and NMP were unaffected by bicarbonate concentration, but

  3. Quantitative Analysis of Bioactive Compounds from Aromatic Plants by Means of Dynamic Headspace Extraction and Multiple Headspace Extraction-Gas Chromatography-Mass Spectrometry.

    PubMed

    Omar, Jone; Olivares, Maitane; Alonso, Ibone; Vallejo, Asier; Aizpurua-Olaizola, Oier; Etxebarria, Nestor

    2016-04-01

    Seven monoterpenes in 4 aromatic plants (sage, cardamom, lavender, and rosemary) were quantified in liquid extracts and directly in solid samples by means of dynamic headspace-gas chromatography-mass spectrometry (DHS-GC-MS) and multiple headspace extraction-gas chromatography-mass spectrometry (MHSE), respectively. The monoterpenes were 1st extracted by means of supercritical fluid extraction (SFE) and analyzed by an optimized DHS-GC-MS. The optimization of the dynamic extraction step and the desorption/cryo-focusing step were tackled independently by experimental design assays. The best working conditions were set at 30 °C for the incubation temperature, 5 min of incubation time, and 40 mL of purge volume for the dynamic extraction step of these bioactive molecules. The conditions of the desorption/cryo-trapping step from the Tenax TA trap were set at follows: the temperature was increased from 30 to 300 °C at 150 °C/min, although the cryo-trapping was maintained at -70 °C. In order to estimate the efficiency of the SFE process, the analysis of monoterpenes in the 4 aromatic plants was directly carried out by means of MHSE because it did not require any sample preparation. Good linearity (r2) > 0.99) and reproducibility (relative standard deviation % <12) was obtained for solid and liquid quantification approaches, in the ranges of 0.5 to 200 ng and 10 to 500 ng/mL, respectively. The developed methods were applied to analyze the concentration of 7 monoterpenes in aromatic plants obtaining concentrations in the range of 2 to 6000 ng/g and 0.25 to 110 μg/mg, respectively. © 2016 Institute of Food Technologists®

  4. Ultrasonic nebulization extraction-heating gas flow transfer-headspace single drop microextraction of essential oil from pericarp of Zanthoxylum bungeanum Maxim.

    PubMed

    Wei, Shigang; Zhang, Huihui; Wang, Yeqiang; Wang, Lu; Li, Xueyuan; Wang, Yinghua; Zhang, Hanqi; Xu, Xu; Shi, Yuhua

    2011-07-22

    The ultrasonic nebulization extraction-heating gas flow transfer coupled with headspace single drop microextraction (UNE-HGFT-HS-SDME) was developed for the extraction of essential oil from Zanthoxylum bungeanum Maxim. The gas chromatography-mass spectrometry was applied to the determination of the constituents in the essential oil. The contents of the constituents from essential oil obtained by the proposed method were found to be more similar to those obtained by hydro-distillation (HD) than those obtained by ultrasonic nebulization extraction coupled with headspace single drop microextraction (UNE-HS-SDME). The heating gas flow was firstly used in the analysis of the essential oil to transfer the analytes from the headspace to the solvent microdrop. The relative standard deviations for determining the five major constituents were in the range from 1.5 to 6.7%. The proposed method is a fast, sensitive, low cost and small sample consumption method for the determination of the volatile and semivolatile constituents in the plant materials. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Evaluation of peroxidative stress of cancer cells in vitro by real-time quantification of volatile aldehydes in culture headspace.

    PubMed

    Shestivska, Violetta; Rutter, Abigail V; Sulé-Suso, Josep; Smith, David; Španěl, Patrik

    2017-08-30

    Peroxidation of lipids in cellular membranes results in the release of volatile organic compounds (VOCs), including saturated aldehydes. The real-time quantification of trace VOCs produced by cancer cells during peroxidative stress presents a new challenge to non-invasive clinical diagnostics, which as described here, we have met with some success. A combination of selected ion flow tube mass spectrometry (SIFT-MS), a technique that allows rapid, reliable quantification of VOCs in humid air and liquid headspace, and electrochemistry to generate reactive oxygen species (ROS) in vitro has been used. Thus, VOCs present in the headspace of CALU-1 cancer cell line cultures exposed to ROS have been monitored and quantified in real time using SIFT-MS. The CALU-1 lung cancer cells were cultured in 3D collagen to mimic in vivo tissue. Real-time SIFT-MS analyses focused on the volatile aldehydes: propanal, butanal, pentanal, hexanal, heptanal and malondialdehyde (propanedial), that are expected to be products of cellular membrane peroxidation. All six aldehydes were identified in the culture headspace, each reaching peak concentrations during the time of exposure to ROS and eventually reducing as the reactants were depleted in the culture. Pentanal and hexanal were the most abundant, reaching concentrations of a few hundred parts-per-billion by volume, ppbv, in the culture headspace. The results of these experiments demonstrate that peroxidation of cancer cells in vitro can be monitored and evaluated by direct real-time analysis of the volatile aldehydes produced. The combination of adopted methodology potentially has value for the study of other types of VOCs that may be produced by cellular damage. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Simplex optimization of headspace factors for headspace gas chromatography determination of residual solvents in pharmaceutical products.

    PubMed

    Grodowska, Katarzyna; Parczewski, Andrzej

    2013-01-01

    The purpose of the present work was to find optimum conditions of headspace gas chromatography (HS-GC) determination of residual solvents which usually appear in pharmaceutical products. Two groups of solvents were taken into account in the present examination. Group I consisted of isopropanol, n-propanol, isobutanol, n-butanol and 1,4-dioxane and group II included cyclohexane, n-hexane and n-heptane. The members of the groups were selected in previous investigations in which experimental design and chemometric methods were applied. Four factors were taken into consideration in optimization which describe HS conditions: sample volume, equilibration time, equilibrium temperature and NaCl concentration in a sample. The relative GC peak area served as an optimization criterion which was considered separately for each analyte. Sequential variable size simplex optimization strategy was used and the progress of optimization was traced and visualized in various ways simultaneously. The optimum HS conditions appeared different for the groups of solvents tested, which proves that influence of experimental conditions (factors) depends on analyte properties. The optimization resulted in significant signal increase (from seven to fifteen times).

  7. Magnetic headspace adsorptive extraction of chlorobenzenes prior to thermal desorption gas chromatography-mass spectrometry.

    PubMed

    Vidal, Lorena; Ahmadi, Mazaher; Fernández, Elena; Madrakian, Tayyebeh; Canals, Antonio

    2017-06-08

    This study presents a new, user-friendly, cost-effective and portable headspace solid-phase extraction technique based on graphene oxide decorated with iron oxide magnetic nanoparticles as sorbent, located on one end of a small neodymium magnet. Hence, the new headspace solid-phase extraction technique has been called Magnetic Headspace Adsorptive Extraction (Mag-HSAE). In order to assess Mag-HSAE technique applicability to model analytes, some chlorobenzenes were extracted from water samples prior to gas chromatography-mass spectrometry determination. A multivariate approach was employed to optimize the experimental parameters affecting Mag-HSAE. The method was evaluated under optimized extraction conditions (i.e., sample volume, 20 mL; extraction time, 30 min; sorbent amount, 10 mg; stirring speed, 1500 rpm, and ionic strength, non-significant), obtaining a linear response from 0.5 to 100 ng L -1 for 1,3-DCB, 1,4-DCB, 1,2-DCB, 1,3,5-TCB, 1,2,4-TCB and 1,2,3-TCB; from 0.5 to 75 ng L -1 for 1,2,4,5-TeCB, and PeCB; and from 1 to 75 ng L -1 for 1,2,3,4-TeCB. The repeatability of the proposed method was evaluated at 10 ng L -1 and 50 ng L -1 spiking levels, and coefficients of variation ranged between 1.5 and 9.5% (n = 5). Limits of detection values were found between 93 and 301 pg L -1 . Finally, tap, mineral and effluent water were selected as real water samples to assess method applicability. Relative recoveries varied between 86 and 110% showing negligible matrix effects. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Characterization of the volatile organic compounds present in the headspace of decomposing human remains.

    PubMed

    Hoffman, Erin M; Curran, Allison M; Dulgerian, Nishan; Stockham, Rex A; Eckenrode, Brian A

    2009-04-15

    Law enforcement agencies frequently use canines trained to detect the odor of human decomposition to aid in determining the location of clandestine burials and human remains deposited or scattered on the surface. However, few studies attempt to identify the specific volatile organic compounds (VOCs) that elicit an appropriate response from victim recovery (VR) canines. Solid-phase microextraction (SPME) was combined with gas chromatography-mass spectrometry (GC-MS) to identify the VOCs released into the headspace associated with 14 separate tissue samples of human remains previously used for VR canine training. The headspace was found to contain various classes of VOCs, including acids, alcohols, aldehydes, halogens, aromatic hydrocarbons, ketones, and sulfides. Analysis of the data indicates that the VOCs associated with human decomposition share similarities across regions of the body and across types of tissue. However, sufficient differences exist to warrant VR canine testing to identify potential mimic odor chemical profiles that can be used as training aids. The resulting data will assist in the identification of the most suitable mixture and relative concentrations of VOCs to appropriately train VR canines.

  9. Saltstone SDU6 Modeling Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Si Y.; Hyun, Sinjae

    2013-01-10

    A new disposal unit, designated as Saltstone Disposal Unit 6 (SDU6), is being designed for support of site accelerated closure goals and salt waste projections identified in the new Liquid Waste System Plan. The unit is a cylindrical disposal cell of 375 ft in diameter and 43 ft in height, and it has a minimum 30 million gallons of capacity. SRNL was requested to evaluate the impact of an increased grout placement height on the flow patterns radially spread on the floor and to determine whether grout quality is impacted by the height. The primary goals of the work aremore » to develop the baseline Computational Fluid Dynamics (CFD) model and to perform the evaluations for the flow patterns of grout material in SDU6 as a function of elevation of grout discharge port and grout rheology. Two transient grout models have been developed by taking a three-dimensional multiphase CFD approach to estimate the domain size of the grout materials radially spread on the facility floor and to perform the sensitivity analysis with respect to the baseline design and operating conditions such as elevation height of the discharge port and fresh grout properties. For the CFD modeling calculations, air-grout Volume of Fluid (VOF) method combined with Bingham plastic and time-dependent grout models were used for examining the impact of fluid spread performance for the initial baseline configurations and to evaluate the impact of grout pouring height on grout quality. The grout quality was estimated in terms of the air volume fraction for the grout layer formed on the SDU6 floor, resulting in the change of grout density. The study results should be considered as preliminary scoping analyses since benchmarking analysis is not included in this task scope. Transient analyses with the Bingham plastic model were performed with the FLUENTTM code on the high performance parallel computing platform in SRNL. The analysis coupled with a transient grout aging model was performed by using ANSYS

  10. Detecting gravesoil with headspace analysis with adsorption on short porous layer open tubular (PLOT) columns.

    PubMed

    Lovestead, Tara M; Bruno, Thomas J

    2011-01-30

    Victims of crimes are often buried in clandestine graves. There are several techniques for finding buried bodies or the scattered remains of a victim; however, none of these methods are very reliable or work in all scenarios. One way to detect gravesoil is to detect the biochemical changes of the surrounding soil due to cadaver decomposition, for example, the release of nitrogenous compounds. A simple and low-cost way to detect these compounds is based on the reaction of alpha amino groups with ninhydrin to form Ruhemann's purple. This test for ninhydrin-reactive nitrogen (NRN) has, to date, only been performed by direct solvent extraction of soil samples. Here, we present a method that detects trace quantities of NRN in the headspace air above gravesoil. Our method is based on an improved purge and trap method developed in our lab for sampling low volatility compounds, as well as volatile compounds at trace quantities, by applying low temperature collection on short alumina-coated porous layer open tubular (PLOT) columns. We modified this method to sample the headspace air above gravesoil with a motorized pipetter and a PLOT column at ambient temperatures. We generated gravesoil using rat cadavers and local soil. Trace quantities of NRN were successfully detected in the headspace air above gravesoil. We report the quantities of NRN recovered for buried rats, rats laid on top of soil, and blank graves (no rats) as a function of time (weeks to months). This work is the first (and thus far, only) example of a method for detecting NRN in the vapor phase, providing another tool for forensic investigators to aid in locating elusive clandestine graves. Published by Elsevier Ireland Ltd.

  11. Analysis of volatile compounds responsible for kiwifruit aroma by desiccated headspace gas chromatography-mass spectrometry.

    PubMed

    Zhang, Chun-Yun; Zhang, Qiong; Zhong, Cai-Hong; Guo, Ming-Quan

    2016-04-01

    A new method for desiccated headspace (DHS) sampling of aqueous sample to GC-MS for the analysis of volatile compounds responsible for kiwifruit aroma in different kiwifruit cultivars has been developed based on the complete hydrate formation between the sample solvent (water) with anhydrous salt (calcium chloride) at an elevated temperature (above the boiling point of the aqueous sample) in a non-contact format, which overcame the water-effect challenge to directly introduce aqueous sample into GC-MS analysis. By means of DHS, the volatile compounds in three different kiwifruit cultivars were analyzed and compared under the optimized operating conditions, mainly time and temperature for headspace equilibration, column temperature program for GC-MS measurement. As a result, 20 peaks of volatile compounds responsible for kiwifruit aroma were detected and remarkable differences were found in the relative contents of three major volatile compounds among the three different kiwifruit cultivars, i.e., acetaldehyde, ethanol and furfural. The DHS sampling technique used in the present method can make the GC-MS analysis of volatile compounds in the aqueous sample within complex matrix possible without contaminating the GC-MS instrument. In terms of the analysis of volatile compounds in kiwifruit, the present method enabled a direct measurement on the filtrate of the aqueous kiwifruit pulp, without intermediate trap phase for the extraction of analytes, which will be more reliable and simpler as compared with any other headspace method in use. Thus, DHS coupled with GC-MS will be a new valuable tool available for the kiwifruit related research and organoleptic quality control. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Comparison of traditional gas chromatography (GC), headspace GC, and the microbial identification library GC system for the identification of Clostridium difficile.

    PubMed Central

    Cundy, K V; Willard, K E; Valeri, L J; Shanholtzer, C J; Singh, J; Peterson, L R

    1991-01-01

    Three gas chromatography (GC) methods were compared for the identification of 52 clinical Clostridium difficile isolates, as well as 17 non-C. difficile Clostridium isolates. Headspace GC and Microbial Identification System (MIS) GC, an automated system which utilizes a software library developed at the Virginia Polytechnic Institute to identify organisms based on the fatty acids extracted from the bacterial cell wall, were compared against the reference method of traditional GC. Headspace GC and MIS were of approximately equivalent accuracy in identifying the 52 C. difficile isolates (52 of 52 versus 51 of 52, respectively). However, 7 of 52 organisms required repeated sample preparation before an identification was achieved by the MIS method. Both systems effectively differentiated C. difficile from non-C. difficile clostridia, although the MIS method correctly identified only 9 of 17. We conclude that the headspace GC system is an accurate method of C. difficile identification, which requires only one-fifth of the sample preparation time of MIS GC and one-half of the sample preparation time of traditional GC. PMID:2007632

  13. Quantitative fingerprinting by headspace--two-dimensional comprehensive gas chromatography-mass spectrometry of solid matrices: some challenging aspects of the exhaustive assessment of food volatiles.

    PubMed

    Nicolotti, Luca; Cordero, Chiara; Cagliero, Cecilia; Liberto, Erica; Sgorbini, Barbara; Rubiolo, Patrizia; Bicchi, Carlo

    2013-10-10

    The study proposes an investigation strategy that simultaneously provides detailed profiling and quantitative fingerprinting of food volatiles, through a "comprehensive" analytical platform that includes sample preparation by Headspace Solid Phase Microextraction (HS-SPME), separation by two-dimensional comprehensive gas chromatography coupled with mass spectrometry detection (GC×GC-MS) and data processing using advanced fingerprinting approaches. Experiments were carried out on roasted hazelnuts and on Gianduja pastes (sugar, vegetable oil, hazelnuts, cocoa, nonfat dried milk, vanilla flavorings) and demonstrated that the information potential of each analysis can better be exploited if suitable quantitation methods are applied. Quantitation approaches through Multiple Headspace Extraction and Standard Addition were compared in terms of performance parameters (linearity, precision, accuracy, Limit of Detection and Limit of Quantitation) under headspace linearity conditions. The results on 19 key analytes, potent odorants, and technological markers, and more than 300 fingerprint components, were used for further processing to obtain information concerning the effect of the matrix on volatile release, and to produce an informative chemical blueprint for use in sensomics and flavoromics. The importance of quantitation approaches in headspace analysis of solid matrices of complex composition, and the advantages of MHE, are also critically discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Highly porous nanostructured copper foam fiber impregnated with an organic solvent for headspace liquid-phase microextraction.

    PubMed

    Saraji, Mohammad; Ghani, Milad; Rezaei, Behzad; Mokhtarianpour, Maryam

    2016-10-21

    A new headspace liquid-phase microextraction technique based on using a copper foam nanostructure substrate followed by gas chromatography-flame ionization detection was developed for the determination of volatile organic compounds in water and wastewater samples. The copper foam with highly porous nanostructured walls was fabricated on the surface of a copper wire by a rapid and facile electrochemical process and used as the extractant solvent holder. Propyl benzoate was immobilized in the pores of the copper foam coating and used for the microextraction of benzene, toluene, ethylbenzene and xylenes. The experimental parameters such as the type of organic solvent, desorption temperature, desorption time, salt concentration, sample temperature, equilibrium time and extraction time, were investigated and optimized. Under the optimum conditions, the method detection limit was between 0.06 and 0.25μgL -1 . The relative standard deviation of the method for the analytes at 4-8μgL -1 concentration level ranged from 7.9 to 11%. The fiber-to-fiber reproducibility for three fibers prepared under the same condition was 9.3-12%. The enrichment factor was in the range of 615-744. Different water samples were analyzed for the evaluation of the method in real sample analysis. Relative recoveries for spiked tap, river and wastewater samples were in the range of 85-94%. Finally, the extraction efficiency of the method was compared with those of headspace single drop microextraction and headspace SPME with the commercial fibers. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. River water quality analysis via headspace detection of volatile organic compounds

    NASA Astrophysics Data System (ADS)

    Tang, Johnny Jock Lee; Nishi, Phyllis Jacqueline; Chong, Gabriel Eng Wee; Wong, Martin Gideon; Chua, Hong Siang; Persaud, Krishna; Ng, Sing Muk

    2017-03-01

    Human civilization has intensified the interaction between the community and the environment. This increases the threat on the environm ent for being over exploited and contaminated with m anmade products and synthetic chemicals. Of all, clean water is one of the resources that can be easily contaminated since it is a universal solvent and of high mobility. This work reports the development and optimization of a water quality monitoring system based on metal oxide sensors. The system is intended to a ssist the detection of volatile organic compounds (VOCs) present in water sources online and onsite. The sampling mechanism was based on contactless mode, where headspace partial pressure of the VOCs formed above the water body in a close chamber was drawn for detection at the sensor platform. Pure toluene was used as standard to represent the broad spectrum of VOCs, and the sensor dynamic range was achieved from 1-1000 ppb. Several sensing parameters such as sampling time, headspace volume, and sensor recovery were s tudied and optimized. Besides direct detection of VOC contaminants in the water, the work has also been extended to detect VOCs produced by microbial communities and to c orrelate the size of the communities with the reading of V OCs recorded. This can serve to give b etter indication of water quality, not only on the conce ntration of VOCs c ontamination from chemicals, but also the content of microbes, which some can have severe effect on human health.

  16. Application of headspace solid phase microextraction for study of noncovalent interaction of borneol with human serum albumin

    PubMed Central

    Hu, Liang; Chen, Dong-ying

    2009-01-01

    Aim: To investigate noncovalent interactions between borneol and human serum albumin (HSA) under near-physiological conditions. Methods: A 65-μm polydimethylsiloxane (PDMS) fiber was selected for sampling. The extraction temperature was kept at 37 °C, and the extraction time was optimized at 10 min. Borneol solutions of different concentrations were equilibrated in 600 μmol/L HSA and 67 mmol/L phosphate buffer solution (pH 7.4, 37 °C) for 24 h prior to solid phase microextraction (SPME) using headspace mode. The binding properties were obtained based on the calculation of extracted borneol amount using gas chromatography (GC) determination. Results: The headspace SPME extraction method avoided disturbance from the HSA binding matrix. The recovery showed good linearity for the borneol concentrations over the range of 0.4–16.3 μmol/L with a regression coefficient (R2) of 0.9998. The limit of detection and lower limit of quantitation were determined to be 0.01 μmol/L and 0.4 μmol/L, respectively. The binding constant and the percentage binding rate were estimated to be 2.4×103(mol/L)-1 and 59.5%, respectively. Conclusion: Headspace SPME coupled to GC is a simple, sensitive and rapid method for the study of borneol binding to HSA. The method may be applied in the determination of other protein binding properties in human plasma. PMID:19890364

  17. Optimization of headspace solid phase micro-extraction of volatile compounds from papaya fruit assisted by GC-olfactometry.

    PubMed

    da Rocha, Renier Felinto Julião; da Silva Araújo, Ídila Maria; de Freitas, Sílvia Maria; Dos Santos Garruti, Deborah

    2017-11-01

    Optimization of the extraction conditions to investigate the volatile composition of papaya fruit involving headspace solid phase micro-extraction was carried out using multivariate strategies such as factorial design and response surface methodology. The performance of different combinations of time for reaching the equilibrium in the headspace and time for maximum extraction of volatiles was evaluated by GC-olfactometry of the extract (intensity of papaya characteristic aroma), number of peaks and total area in the chromatogram. Thirty-two compounds were identified by GC-MS under the optimized extraction conditions, the majority of which were aldehydes, both in number of compounds and area. Major compounds were δ-octalactone, β-citral, benzaldehyde, heptanal, benzyl isothiocyanate, isoamyl acetate, γ-octalactone, (E)-linalool oxide and benzyl alcohol. Seven aldehydes and two other compounds are reported for the first time in papaya's volatile profile.

  18. Characterization of mesoporous silica used for drug delivery by sorptive interaction - multiple headspace extraction-gas chromatography.

    PubMed

    Aspromonte, Juan; Wolfs, Kris; Kahsay, Getu; Van Schepdael, Ann; Adams, Erwin

    2018-09-01

    A multiple headspace extraction experiment coupled to gas chromatography (MHE-GC) is used for the classification and qualification of different mesoporous silica (MPSi) materials used for drug delivery. In this MHE experiment, a pure liquid solvent probe is fully evaporated in a sealed headspace vial in the presence of the MPSi sample, leading to a gas-solid partitioning that is theoretically described. The obtained results matched with the known characteristics of the studied samples, such as adsorption capacity due to differences in porosity and passivation treatments. Moreover, it proves the effectiveness of a poly dimethyl siloxane (PDMS) coating treatment over a thermal one in reducing the specific interactions of the MPSi. In addition, it evidences the important role of confinement effects when the pore diameter is close to the microporosity range. Finally, a simple experiment for fast screening is proposed by comparison of the results obtained for four different probes used as a mixture. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Using Single Drop Microextraction for Headspace Analysis with Gas Chromatography

    NASA Astrophysics Data System (ADS)

    Riccio, Daniel; Wood, Derrick C.; Miller, James M.

    2008-07-01

    Headspace (HS) gas chromatography (GC) is commonly used to analyze samples that contain non-volatiles. In 1996, a new sampling technique called single drop microextraction, SDME, was introduced, and in 2001 it was applied to HS analysis. It is a simple technique that uses equipment normally found in the undergraduate laboratory, making it ideal for instructional use, especially to illustrate HS analysis or as an alternative to solid-phase microextraction (SPME) to which it is very similar. The basic principles and practice of HS-GC using SDME are described, including a complete review of the literature. Some possible experiments are suggested using water and N -methylpyrrolidone (NMP) as solvents.

  20. Calibration-free sensor for pressure and H2O concentration in headspace of sterile vial using tunable diode laser absorption spectroscopy.

    PubMed

    Cai, Tingdong; Gao, Guangzhen; Liu, Ying

    2013-11-10

    Tunable diode laser absorption measurements of pressure and H2O concentration in the headspace of vials using a distributed-feedback (DFB) diode laser near 1.4 μm are reported. A H2O line located near 7161.41 cm(-1) is selected based on its strong absorption strength and isolation from interference of neighboring transitions. Direct absorption spectra of H2O are obtained for the measurement path as well as the reference path by scanning the laser wavelength. The pressure and H2O vapor concentration in the headspace of a vial are inferred from a differential absorption signal, which is the difference between the measured and the referenced absorbance spectra. This sensor is calibration-free and no purge gas is needed. The demonstrated capability would enable measurements of pressure and H2O concentration in the headspace of vials within 2.21% and 2.86%, respectively. A precision of 1.02 Torr and 390 ppm is found for the pressure and H2O concentration, respectively. A set of measurements for commercial freeze-dried products are also performed to illustrate the usefulness of this sensor.

  1. Full evaporation headspace gas chromatography for sensitive determination of high boiling point volatile organic compounds in low boiling matrices.

    PubMed

    Mana Kialengila, Didi; Wolfs, Kris; Bugalama, John; Van Schepdael, Ann; Adams, Erwin

    2013-11-08

    Determination of volatile organic components (VOC's) is often done by static headspace gas chromatography as this technique is very robust and combines easy sample preparation with good selectivity and low detection limits. This technique is used nowadays in different applications which have in common that they have a dirty matrix which would be problematic in direct injection approaches. Headspace by nature favors the most volatile compounds, avoiding the less volatile to reach the injector and column. As a consequence, determination of a high boiling solvent in a lower boiling matrix becomes challenging. Determination of VOCs like: xylenes, cumene, N,N-dimethylformamide (DMF), dimethyl sulfoxide (DMSO), N,N-dimethylacetamide (DMA), N-methyl-2-pyrrolidone (NMP), 1,3-dimethyl-2-imidazolidinone (DMI), benzyl alcohol (BA) and anisole in water or water soluble products are an interesting example of the arising problems. In this work, a headspace variant called full evaporation technique is worked out and validated for the mentioned solvents. Detection limits below 0.1 μg/vial are reached with RSD values below 10%. Mean recovery values ranged from 92.5 to 110%. The optimized method was applied to determine residual DMSO in a water based cell culture and DMSO and DMA in tetracycline hydrochloride (a water soluble sample). Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Headspace profiling of cocaine samples for intelligence purposes.

    PubMed

    Dujourdy, Laurence; Besacier, Fabrice

    2008-08-06

    A method for determination of residual solvents in illicit hydrochloride cocaine samples using static headspace-gas chromatography (HS-GC) associated with a storage computerized procedure is described for the profiling and comparison of seizures. The system involves a gas chromatographic separation of 18 occluded solvents followed by fully automatic data analysis and transfer to a PHP/MySQL database. First, a fractional factorial design was used to evaluate the main effects of some critical method parameters (salt choice, vial agitation intensity, oven temperature, pressurization and loop equilibration) on the results with a minimum of experiments. The method was then validated for tactical intelligence purposes (batch comparison) via several studies: selection of solvents and mathematical comparison tool, reproducibility and "cutting" influence studies. The decision threshold to determine the similarity of two samples was set and false positives and negatives evaluated. Finally, application of the method to distinguish geographical origins is discussed.

  3. Determination of lysine content based on an in situ pretreatment and headspace gas chromatographic measurement technique.

    PubMed

    Wan, Xiao-Fang; Liu, Bao-Lian; Yu, Teng; Yan, Ning; Chai, Xin-Sheng; Li, You-Ming; Chen, Guang-Xue

    2018-05-01

    This work reports on a simple method for the determination of lysine content by an in situ sample pretreatment and headspace gas chromatographic measurement (HS-GC) technique, based on carbon dioxide (CO 2 ) formation from the pretreatment reaction (between lysine and ninhydrin solution) in a closed vial. It was observed that complete lysine conversion to CO 2 could be achieved within 60 min at 60 °C in a phosphate buffer medium (pH = 4.0), with a minimum molar ratio of ninhydrin/lysine of 16. The results showed that the method had a good precision (RSD < 5.23%) and accuracy (within 6.80%), compared to the results measured by a reference method (ninhydrin spectroscopic method). Due to the feature of in situ sample pretreatment and headspace measurement, the present method becomes very simple and particularly suitable to be used for batch sample analysis in lysine-related research and applications. Graphical abstract The flow path of the reaction and HS-GC measurement for the lysine analysis.

  4. Efficient quantification of water content in edible oils by headspace gas chromatography with vapour phase calibration.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-06-01

    An automated and accurate headspace gas chromatographic (HS-GC) technique was investigated for rapidly quantifying water content in edible oils. In this method, multiple headspace extraction (MHE) procedures were used to analyse the integrated water content from the edible oil sample. A simple vapour phase calibration technique with an external vapour standard was used to calibrate both the water content in the gas phase and the total weight of water in edible oil sample. After that the water in edible oils can be quantified. The data showed that the relative standard deviation of the present HS-GC method in the precision test was less than 1.13%, the relative differences between the new method and a reference method (i.e. the oven-drying method) were no more than 1.62%. The present HS-GC method is automated, accurate, efficient, and can be a reliable tool for quantifying water content in edible oil related products and research. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. A high-throughput headspace gas chromatographic technique for the determination of nitrite content in water samples.

    PubMed

    Zhang, Shu-Xin; Peng, Rong; Jiang, Ran; Chai, Xin-Sheng; Barnes, Donald G

    2018-02-23

    This paper reports on a high-throughput headspace gas chromatographic method (HS-GC) for the determination of nitrite content in water sample, based on GC measurement of cyclohexene produced from the reaction between nitrite and cyclamate in a closed vial. The method has a relative standard deviation of <3.5%; The differences between the results of the nitrite measurements obtained by this method and those of a reference method were less than 5.8% and the recoveries of the method were in the range of 94.8-102% (for a spiked nitrite content range from 0.002 to 0.03 mg/L). The limit of detection of the method was 0.46 μg L -1 . Due to an overlapping mode in the headspace auto-sampler system, the method can provide an automated and high-throughput nitrite analysis for the surface water samples. In short, the present HS-GC method is simple, accurate, and sensitive, and it is very suitable to be used in the batch sample testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Quantitative analysis of total starch content in wheat flour by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-09-01

    This paper proposed a new reaction headspace gas chromatographic (HS-GC) method for efficiently quantifying the total starch content in wheat flours. A certain weight of wheat flour was oxidized by potassium dichromate in an acidic condition in a sealed headspace vial. The results show that the starch in wheat flour can be completely transferred to carbon dioxide at the given conditions (at 100 °C for 40 min) and the total starch content in wheat flour sample can be indirectly quantified by detecting the CO 2 formed from the oxidation reaction. The data showed that the relative standard deviation of the reaction HS-GC method in the precision test was less than 3.06%, and the relative differences between the new method and the reference method (titration method) were no more than 8.90%. The new reaction HS-GC method is automated, accurate, and can be a reliable tool for determining the total starch content in wheat flours in both laboratory and industrial applications. Graphical abstract The total starch content in wheat flour can be indirectly quantified by the GC detection of the CO 2 formed from the oxidation reaction between wheat flour and potassium dichromate in an acidic condition.

  7. Headspace volatile markers for sensitivity of cocoa (Theobroma cacao L.) somatic embryos to cryopreservation.

    PubMed

    Fang, Jong-Yi; Wetten, Andrew; Johnston, Jason

    2008-03-01

    The mechanisms that reduce the viability of plant somatic embryos following cryopreservation are not known. The objective of the present study was to evaluate the sensitivity of cocoa (Theobroma cacao L.) somatic embryos at different stages of an encapsulation-dehydration protocol using stress-related volatile hydrocarbons as markers of injury and recovery. The plant stress hormone ethylene and volatile hydrocarbons derived from hydroxyl radicals (methane) and lipid peroxidation (ethane) were determined using gas chromatography headspace analysis. Ethylene and methane were the only volatiles detected, with both being produced after each step of the cryogenic protocol. Ethylene production was significantly reduced following exposure to liquid nitrogen, but then increased in parallel with embryo recovery. In contrast, the production of methane was cyclic during recovery, with the first cycle occurring earlier for embryos recovered from liquid nitrogen and desiccation than those recovered from earlier steps in the protocol. These results suggest that loss of somatic embryo viability during cryopreservation may be related to the oxidative status of the tissue, and its capacity to produce ethylene. This study has demonstrated that headspace volatile analysis provides a robust non-destructive analytical approach for assessing the survival and recovery of plant somatic embryos following cryopreservation.

  8. A pressure-affected headspace-gas chromatography method for determining calcium carbonate content in paper sample.

    PubMed

    Dai, Yi; Yu, Zhen-Hua; Zhan, Jian-Bo; Chai, Xin-Sheng; Zhang, Shu-Xin; Xie, Wei-Qi; He, Liang

    2017-07-21

    The present work reports on the development of a pressure-affected based headspace (HS) analytical technique for the determination of calcium carbonate content in paper samples. By the acidification, the carbonate in the sample was converted to CO 2 and released into the headspace of a closed vial and then measured by gas chromatography (GC). When the amount of carbonate in the sample is significant, the pressure created by the CO 2 affects the accuracy of the method. However, the pressure also causes a change in the O 2 signal in the HS-GC measurement, which is a change that can be used as an indirect measure of the carbonate in the sample. The results show that the present method has a good precision (the relative standard deviation<2.32%), and good accuracy (the relative differences compared to a reference method was<5.76%). Coupled with the fact that the method is simple, rapid, and accurate, it is suitable for a variety of applications that call for the analysis of high carbonate content in paper samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Method for distributing chemicals through a fibrous material using low-headspace dielectric heating

    DOEpatents

    Banerjee, Sujit; Malcolm, Earl

    2002-01-01

    System and method for diffusing chemicals rapidly and evenly into and through fibrous material, such as wood. Chemicals are introduced into the fibrous material by applying the chemicals to the fibrous material. After treating the fibrous material with the chemicals, the fibrous material is maintained under low-headspace conditions. Thermal energy or dielectric heating, such as microwave or radio frequency energy, is applied to the fibrous material. As a result, the chemicals are able to distribute evenly and quickly throughout the fibrous material.

  10. [Determination of flavor compounds in foxtail millet wine by gas chromatography-mass spectrometry coupled with headspace solid phase microextraction].

    PubMed

    Liu, Jingke; Zhang, Aixia; Li, Shaohui; Zhao, Wei; Zhang, Yuzong; Xing, Guosheng

    2017-11-08

    To comprehensively understand flavor compounds and aroma characteristics of foxtail millet wine, extraction conditions were optimized with 85 μm polyacrylate (PA), 100 μm polydimethylsiloxane (PDMS), 75 μm carboxen (CAR)/PDMS and 50/30 μm divinylbenzene (DVB)/CAR/PDMS fibers. The flavor compounds in foxtail millet wine were investigated by gas chromatography-mass spectrometry (GC-MS) coupled with headspace solid phase microextraction (HS-SPME), and the odor characteristics and intensity were analyzed by odor active values (OAVs). The samples of 8 mL were placed in headspace vials with 1.5 g NaCl, then the headspace vials were heated at 60℃ for 40 min. Using HS-SPME with different fibers, a total of 55 flavor compounds were identified from the samples, including alcohols, esters, benzene derivatives, hydrocarbons, acids, aldehydes, ketones, terpenes, phenols and heterocycle compounds. The main flavor compounds were alcohols compounds. According to their OAVs, phenylethyl alcohol, styrene, 1-methyl-naphthalene, 2-methyl-naphthalene, benzaldehyde, benzeneacetaldehyde and 2-methoxy-phenol were established to be odor-active compounds. Phenylethyl alcohol and benzeneacetaldehyde were the most prominent odor-active compounds. PA and PDMS fibers had good extraction effect for polar and nonpolar compounds, respectively. CAR/PDMS and DVB/CAR/PDMS provided a similar compounds profile for moderate polar compounds. This research comprehensively determined flavor compounds of foxtail millet wine, and provided theoretical basis for product development and quality control.

  11. Direct synthesis of nitrogen-doped graphene on platinum wire as a new fiber coating method for the solid-phase microextraction of BXes in water samples: Comparison of headspace and cold-fiber headspace modes.

    PubMed

    Memarian, Elham; Hosseiny Davarani, Saied Saeed; Nojavan, Saeed; Movahed, Siyavash Kazemi

    2016-09-07

    In this work, a new solid-phase microextraction fiber was prepared based on nitrogen-doped graphene (N-doped G). Moreover, a new strategy was proposed to solve problems dealt in direct coating of N-doped G. For this purpose, first, Graphene oxide (GO) was coated on Pt wire by electrophoretic deposition method. Then, chemical reduction of coated GO to N-doped G was accomplished by hydrazine and NH3. The prepared fiber showed good mechanical and thermal stabilities. The obtained fiber was used in two different modes (conventional headspace solid-phase microextraction and cold-fiber headspace solid-phase microextraction (CF-HS-SPME)). Both modes were optimized and applied for the extraction of benzene and xylenes from different aqueous samples. All effective parameters including extraction time, salt content, stirring rate, and desorption time were optimized. The optimized CF-HS-SPME combined with GC-FID showed good limit of detections (LODs) (0.3-2.3 μg/L), limit of quantifications (LOQs) (1.0-7.0 μg/L) and linear ranges (1.0-5000 μg/L). The developed method was applied for the analysis of benzene and xylenes in rainwater and some wastewater samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Bromination of Aromatic Compounds by Residual Bromide in Sodium Chloride Matrix Modifier Salt During Heated Headspace GC/MS Analysis

    EPA Science Inventory

    Analytical artifacts attributed to the bromination of toluene, xylenes, and trimethylbenzenes were found during the heated headspace gas chromatography/mass spectrometry (GC/MS) analysis of aqueous samples. The aqueous samples were produced from Fenton-like chemical oxidation rea...

  13. Determination of binding-dioxygen in dioxygen complexes by headspace gas chromatography.

    PubMed

    Wang, Wei; Feng, Shun; Li, Ya-ni; Wu, Meiying; Wang, Jide

    2008-06-06

    Dioxygen complexes play important roles in organisms' bodies, so the determination of binding-dioxygen has practical significance. A simple and robust method based on headspace gas chromatography was proposed to determine the binding-dioxygen in dioxygen complexes. By measuring the content change of nitrogen gas in a vial, the amount of oxygen released from dixoygen complexes can be determined. The method was validated using potassium chlorate as model sample, and the results exhibited good recoveries (90-99%) with the relative standard deviation less than 8%. It was also used to analyze dioxygen complex of cobalt bis(salicylaldehyde) ethylenediimine and polyamine cobalt complexes prepared by solid-phase reaction.

  14. Comparison of direct, headspace and headspace cold fiber modes in solid phase microextraction of polycyclic aromatic hydrocarbons by a new coating based on poly(3,4-ethylenedioxythiophene)/graphene oxide composite.

    PubMed

    Banitaba, Mohammad Hossein; Hosseiny Davarani, Saied Saeed; Kazemi Movahed, Siyavash

    2014-01-17

    A novel nanocomposite coating made of poly(3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide was electrochemically prepared on gold wire. The prepared fiber was applied to the solid-phase microextraction (SPME) and gas chromatographic analysis of six polycyclic aromatic hydrocarbons (PAHs). Three modes of extraction i.e. direct immersion (DI), headspace (HS) and headspace cold fiber (HS-CF) in SPME were investigated. The results were compared under optimized conditions of each mode, considering the effects of the three most important parameters which are extraction temperature, extraction time and ionic strength. The comparison showed that HS-CF-SPME results in the best outcome for the extraction of PAHs from water samples. Under the optimized conditions of this mode, the calibration curves were linear within the range of 0.4-600μgL(-1) and the detection limits were between 0.05 and 0.13μgL(-1). The intra-day and inter-day relative standard deviations obtained at 10μgL(-1) (n=5), using a single fiber, were 4.1-6.8% and 4.8-8.4%, respectively. The fiber-to-fiber repeatabilities (n=4), expressed as the relative standard deviations (RSD%), were between 6.5% and 10.7% at a 10μgL(-1) concentration level. The method was successfully applied to the analysis of PAHs in seawater samples showing recoveries from 85% to 107%. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Freeze-thaw method improves the detection of volatile compounds in insects using Headspace Solid-Phase Microextraction (HS-SPME)

    USDA-ARS?s Scientific Manuscript database

    Headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography–mass spectrometry (GC-MS) is commonly used in analyzing insect volatiles. In order to improve the detection of volatiles in insects, a freeze-thaw method was applied to insect samples before the HS-SPME-GC-MS analysis. ...

  16. Determination of the Degree of Substitution of Cationic Guar Gum by Headspace-Based Gas Chromatography during Its Synthesis.

    PubMed

    Wan, Xiaofang; Guo, Congbao; Feng, Jiarui; Yu, Teng; Chai, Xin-Sheng; Chen, Guangxue; Xie, Wei-Qi

    2017-08-16

    This study reports on a headspace-based gas chromatography (HS-GC) technique for determining the degree of substitution (DS) of cationic guar gum during the synthesis process. The method is based on the determination of 2,3-epoxypropyltrimethylammonium chloride in the process medium. After a modest pretreatment procedure, the sample was added to a headspace vial containing bicarbonate solution for measurement of evolved CO 2 by HS-GC. The results showed that the method had a good precision (relative standard deviation of <3.60%) and accuracy for the 2,3-epoxypropyltrimethylammonium chloride measurement, with recoveries in the range of 96-102%, matching with the data obtained by a reference method, and were within 12% of the values obtained by the more arduous Kjeldahl method for the calculated DS of cationic guar gum. The HS-GC method requires only a small volume of sample and, thus, is suitable for determining the DS of cationic guar gum in laboratory-scale process-related applications.

  17. A rapid method for simultaneously determining ethanol and methanol content in wines by full evaporation headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Lin, Neng-Biao; Chai, Xin-Sheng; Zhong-Li; Barnes, Donald G

    2015-09-15

    This work reports on a full evaporation headspace gas chromatographic (FE HS-GC) method for simultaneously determining the ethanol (EtOH) and methanol (MeOH) content in wines. A small sample (10μL) was placed in a headspace sample vial, and a near-complete mass transfer of ethanol and methanol from the liquid sample to the vapor phase was obtained within three minutes at a temperature of 105°C, which allowed the measurement of the EtOH and MeOH content in the sample by GC. The results showed excellent precision and accuracy, as shown by the reproducibilities of 1.02% and 2.11% for EtOH and MeOH, respectively, and recoveries that ranged from 96.1% to 104% for both alcohols. The method is efficient, accurate and suitable for the determination of EtOH and MeOH in wine production and quality control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Detecting volatile compounds from Kraft lignin degradation in the headspace of microbial cultures by selected ion flow tube mass spectrometry (SIFT-MS).

    PubMed

    Gibson, Andrew; Malek, Lada; Dekker, Robert F H; Ross, Brian

    2015-05-01

    Selected Ion Flow Tube Mass Spectrometry (SIFT-MS) was used to quantify methanol and other volatile compounds in the headspace of one bacterial and 12 fungal lignin-degrading microbial cultures. Cultures were grown in 250 mL Erlenmeyer flasks capped with aluminum foil containing 40 mL of nutrient media using Kraft lignin (0.3% w/v) as the sole carbon source. Analysis was done using SIFT-MS with H3O(+) and NO(+) precursors. Product ions were identified with multiple ion mode (MIM). Full scan (FS) mode was used to identify other compounds of interest. Absidia cylindrospora, Ischnoderma resinosum and Pholiota aurivella increased headspace methanol concentration by 136 ppb, 1196 ppb and 278 ppb, respectively, while Flammulina velutipes and Laetiporus sulphureus decreased concentration below ambient levels. F. velutipes and L. sulphureus were found to produce products of methanol oxidation (formaldehyde and formic acid) and were likely metabolizing methanol. Some additional unidentified compounds generated by the fungal cultures are intriguing and will require further study. SIFT-MS can be used to quantify methanol and other volatile compounds in the headspace of microbial cultures and has the potential to be a rapid, sensitive, non-invasive tool useful in elucidating the mechanisms of lignin degradative pathways. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Speciation of butyltin compounds in marine sediments with headspace solid phase microextraction and gas chromatography mass spectrometry.

    PubMed

    Cardellicchio, N; Giandomenico, S; Decataldo, A; Di Leo, A

    2001-03-01

    A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.

  20. Headspace vapor characterization of Hanford Waste Tank 241-BY-108: Results from samples collected January 23, 1996. Tank Vapor Characterization Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pool, K.H.; Evans, J.C.; Thomas, B.L.

    1996-07-01

    This report describes the results of vapor samples obtained to compare vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling System (ISVS) with and without particulate prefiltration. Samples were collected from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) was contracted by Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for water, ammonia, permanent gases, total nonmethane hydrocarbons (TNMHCs, also known as TO-12), and organic analytes in samples collected in SUMMA{trademark} canisters and on triple sorbentmore » traps (TSTs) from the tank headspace. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sampling and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Sampling and Analysis Plan for Tank Vapor Sampling Comparison Test{close_quotes}, and the sample jobs were designated S6004, S6005, and S6006. Samples were collected by WHC on January 23, 1996, using the VSS, a truck-based sampling method using a heated probe; and the ISVS with and without particulate prefiltration.« less

  1. Optimization of dynamic headspace extraction system for measurement of halogenated volatile organic compounds in liquid or viscous samples

    NASA Astrophysics Data System (ADS)

    Taniai, G.; Oda, H.; Kurihara, M.; Hashimoto, S.

    2010-12-01

    Halogenated volatile organic compounds (HVOCs) produced in the marine environment are thought to play a key role in atmospheric reactions, particularly those involved in the global radiation budget and the depression of tropospheric and stratospheric ozone. To evaluate HVOCs concentrations in the various natural samples, we developed an automated dynamic headspace extraction method for the determination of 15 HVOCs, such as chloromethane, bromomethane, bromoethane, iodomethane, iodoethane, bromochloromethane, 1-iodopropane, 2-iodopropane, dibromomethane, bromodichloromethane, chloroiodomethane, chlorodibromomethane, bromoiodomethane, tribromomethane, and diiodomethane. Dynamic headspace system (GERSTEL DHS) was used to purge the gas phase above samples and to trap HVOCs on the adsorbent column from the purge gas. We measured the HVOCs concentrations in the adsorbent column with gas chromatograph (Agilent 6890N)- mass spectrometer (Agilent 5975C). In dynamic headspace system, an glass tube containing Tenax TA or Tenax GR was used as adsorbent column for the collection of 15 HVOCs. The parameters for purge and trap extraction, such as purge flow rate (ml/min), purge volume (ml), incubation time (min), and agitator speed (rpm), were optimized. The detection limits of HVOCs in water samples were 1270 pM (chloromethane), 103 pM (bromomethane), 42.1 pM (iodomethane), and 1.4 to 10.2 pM (other HVOCs). The repeatability (relative standard deviation) for 15 HVOCs were < 9 % except chloromethane (16.2 %) and bromomethane (11.0 %). On the basis of the measurements for various samples, we concluded that this analytical method is useful for the determination of wide range of HVOCs with boiling points between - 24°C (chloromethane) and 181°C (diiodomethane) for the liquid or viscous samples.

  2. Accurate determination of residual acrylic acid in superabsorbent polymer of hygiene products by headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; Jiang, Ran

    2017-02-17

    This work reports on a method for the determination of residual acrylic acid (AA) in the superabsorbent polymers for hygiene products by headspace analysis. It was based on water extraction for the polymer sample at a room temperature for 50min. Then, the AA in the extractant reacted with bicarbonate solution in a closed headspace sample vial, from which the carbon dioxide generated from the reaction (within 20min at 70°C) was detected by gas chromatography (GC). It was found that there is adsorption partition equilibrium of AA between solid-liquid phases. Therefore, an equation for calculating the total AA content in the original polymers sample was derived based on the above phase equilibrium. The results show that the HS-GC method has good precision (RSD<2.51%) and good accuracy (recoveries from 93 to 105%); the limit of quantification (LOQ) was 373mg/kg. The present method is rapid, accurate, and suitable for determining total residual acrylic acid in a wide variety of applications from processing of superabsorbent polymer to commercial products quality control. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Microwave-assisted decomplexation and in-situ headspace in-syringe dynamic derivatization of dimethylamine borane with high performance liquid chromatography-fluorescence detection.

    PubMed

    Muniraj, Sarangapani; Lee, Hua-Kwang; Hsiech, Chunming; Jen, Jen-Fon

    2018-02-16

    A rapid, sensitive, selective, and simple method for monitoring dimethylamine borane (DMAB) in aqueous sample is proposed by combining microwave-assisted de-complexation, headspace liquid phase in-situ derivatization extraction, and high-performance liquid chromatography-fluorescence detection for the determination of DMAB in samples. The present procedure involves de-complexation of DMAB using microwave irradiation, evolution of dimethylamine (DMA) to the headspace from an alkalized sample solution, and dynamic headspace liquid-phase derivatization extraction (Dy-HS-LPDE) of DMA with 9-fluorenylmethyl chloroformate in a syringe barrel. In addition to the optimal Dy-HS-LPDE and chromatographic parameters described in our previous study, the de-complexation of DMAB by thermal and microwave-assisted procedures and evolution of DMA into the headspace from an alkalized solution and modification of the Dy-HS-LPDE method are thoroughly investigated. The results indicate that complete de-complexation was obtained at 70 °C for 5 min, 30 °C for 10 min, or using microwave irradiation for 30 s at any applied power. It indicates that the DMAB complex easily undergoes de-complexation under microwave irradiation. The linearity range was 0.01-0.5 mg L -1 for DMAB and 0.0077-0.38 mg L -1 for DMA, with a coefficient of determination of 0.9995, and limit of detection of 3 μg L -1 (limit of quantitation of 10 μg L -1 ) for DMAB. The recoveries of DMAB are 95.3% (3.0% RSD) for waste water when spiked 0.05 mg L -1 and 93.5% (5.4% RSD) for the samples spiked with copper and nickel salts (5 mM each in the spiked waste sample). The whole analytical procedure can be completed within 25 min. The results confirm that the present method is a rapid, sensitive, selective, automated, low-cost and eco-friendly procedure to identify DMAB in samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Determination of microstickies in recycled whitewater by headspace gas chromatography.

    PubMed

    Chai, X-S; Samp, J C; Yang, Q F; Song, H N; Zhang, D C; Zhu, J Y

    2006-03-03

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid equilibration partitioning of toluene. It was found that the equilibrium concentration of toluene in the vapor phase is inversely proportional to the apparent effective surface area of microstickies that remain in the corresponding solution. Thus, the amount of microsticky materials in the recycled whitewater can be quantified by HS-GC via indirect measurement of the toluene content in the vapor phase of the sample without any pretreatment. The presented method is simple, rapid and automated.

  5. Potential application of microsensor technology in radioactive waste management with emphasis on headspace gas detection.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Chad Edward; Thomas, Michael Loren; Wright, Jerome L.

    2004-09-01

    Waste characterization is probably the most costly part of radioactive waste management. An important part of this characterization is the measurements of headspace gas in waste containers in order to demonstrate the compliance with Resource Conservation and Recovery Act (RCRA) or transportation requirements. The traditional chemical analysis methods, which include all steps of gas sampling, sample shipment and laboratory analysis, are expensive and time-consuming as well as increasing worker's exposure to hazardous environments. Therefore, an alternative technique that can provide quick, in-situ, and real-time detections of headspace gas compositions is highly desirable. This report summarizes the results obtained from amore » Laboratory Directed Research & Development (LDRD) project entitled 'Potential Application of Microsensor Technology in Radioactive Waste Management with Emphasis on Headspace Gas Detection'. The objective of this project is to bridge the technical gap between the current status of microsensor development and the intended applications of these sensors in nuclear waste management. The major results are summarized below: {sm_bullet} A literature review was conducted on the regulatory requirements for headspace gas sampling/analysis in waste characterization and monitoring. The most relevant gaseous species and the related physiochemical environments were identified. It was found that preconcentrators might be needed in order for chemiresistor sensors to meet desired detection {sm_bullet} A long-term stability test was conducted for a polymer-based chemresistor sensor array. Significant drifts were observed over the time duration of one month. Such drifts should be taken into account for long-term in-situ monitoring. {sm_bullet} Several techniques were explored to improve the performance of sensor polymers. It has been demonstrated that freeze deposition of black carbon (CB)-polymer composite can effectively eliminate the so-called 'coffee

  6. Lab-In-Syringe automation of stirring-assisted room-temperature headspace extraction coupled online to gas chromatography with flame ionization detection for determination of benzene, toluene, ethylbenzene, and xylenes in surface waters.

    PubMed

    Horstkotte, Burkhard; Lopez de Los Mozos Atochero, Natalia; Solich, Petr

    2018-06-22

    Online coupling of Lab-In-Syringe automated headspace extraction to gas chromatography has been studied. The developed methodology was successfully applied to surface water analysis using benzene, toluene, ethylbenzene, and xylenes as model analytes. The extraction system consisted of an automatic syringe pump with a 5 mL syringe into which all solutions and air for headspace formation were aspirated. The syringe piston featured a longitudinal channel, which allowed connecting the syringe void directly to a gas chromatograph with flame ionization detector via a transfer capillary. Gas injection was achieved via opening a computer-controlled pinch valve and compressing the headspace, upon which separation was initialized. Extractions were performed at room temperature; yet sensitivity comparable to previous work was obtained by high headspace to sample ratio V HS /V Sample of 1.6:1 and injection of about 77% of the headspace. Assistance by in-syringe magnetic stirring yielded an about threefold increase in extraction efficiency. Interferences were compensated by using chlorobenzene as an internal standard. Syringe cleaning and extraction lasting over 10 min was carried out in parallel to the chromatographic run enabling a time of analysis of <19 min. Excellent peak area repeatabilities with RSD of <4% when omitting and <2% RSD when using internal standard corrections on 100 μg L -1 level were achieved. An average recovery of 97.7% and limit of detection of 1-2 μg L -1 were obtained in analyses of surface water. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Systematic comparison of static and dynamic headspace sampling techniques for gas chromatography.

    PubMed

    Kremser, Andreas; Jochmann, Maik A; Schmidt, Torsten C

    2016-09-01

    Six automated, headspace-based sample preparation techniques were used to extract volatile analytes from water with the goal of establishing a systematic comparison between commonly available instrumental alternatives. To that end, these six techniques were used in conjunction with the same gas chromatography instrument for analysis of a common set of volatile organic carbon (VOC) analytes. The methods were thereby divided into three classes: static sampling (by syringe or loop), static enrichment (SPME and PAL SPME Arrow), and dynamic enrichment (ITEX and trap sampling). For PAL SPME Arrow, different sorption phase materials were also included in the evaluation. To enable an effective comparison, method detection limits (MDLs), relative standard deviations (RSDs), and extraction yields were determined and are discussed for all techniques. While static sampling techniques exhibited sufficient extraction yields (approx. 10-20 %) to be reliably used down to approx. 100 ng L(-1), enrichment techniques displayed extraction yields of up to 80 %, resulting in MDLs down to the picogram per liter range. RSDs for all techniques were below 27 %. The choice on one of the different instrumental modes of operation (aforementioned classes) was thereby the most influential parameter in terms of extraction yields and MDLs. Individual methods inside each class showed smaller deviations, and the least influences were observed when evaluating different sorption phase materials for the individual enrichment techniques. The option of selecting specialized sorption phase materials may, however, be more important when analyzing analytes with different properties such as high polarity or the capability of specific molecular interactions. Graphical Abstract PAL SPME Arrow during the extraction of volatile analytes from the headspace of an aqueous sample.

  8. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    PubMed

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  9. [Analysis of the components of floral scent in Glochidion puberum using gas chromatography-mass spectrometry with dynamic headspace adsorption].

    PubMed

    Huang, Daihong; Zhang, Zhenguo; Chen, Guoping; Li, Houhun; Shi, Fuchen

    2015-03-01

    The floral scent plays the important key role in maintaining the obligate pollination mutualism between Glochidion plants and Epicephala moths. In the study, the dynamic headspace adsorption technique was employed to collect the floral scent emitted by Glochidion puberum, gas chromatography coupled with mass spectrometry (GC-MS) was used for the detection and identification of volatile chemical components in headspace samples of flowers from G. puberum. The peak area normalization was used to determine the relative contents of each odour component. The results showed that 45 compounds mainly consisting of monoterpenes and sesquiterpenes were isolated from the floral scent produced by G. puberum. Especially, both linalool (38.06%) and β-elemene (23.84%) were considered as the major scent components of G. puberum. It was speculated that linalool and β-elemene may be the two potential compounds attracting female Epicephala moths. The study provided the basic data for further electroantennographic detection and bioassays to identify the compounds having the actual physiological activity to female Epicephala moths.

  10. Headspace vapor characterization of Hanford Waste Tank 241-S-102: Results from samples collected on January 26, 1996. Tank Vapor Characterization Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, J.C.; Thomas, B.L.; Pool, K.H.

    1996-07-01

    This report describes the results of vapor samples obtained to compare vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling System (ISVS) with and without particulate prefiltration. Samples were collected from the headspace of waste storage tank 241-S-102 (Tank S-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) was contracted by Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for water, ammonia, permanent gases, total nonmethane hydrocarbons (TNMHCs, also known as TO-12), and organic analytes in samples collected in SUMMA{trademark} canisters and on triple sorbentmore » traps (TSTs) from the tank headspace. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sampling and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was {open_quotes}Sampling and Analysis Plan for Tank Vapor Sampling Comparison Test{close_quote}, and the sample jobs were designated S6007, S6008, and S6009. Samples were collected by WHC on January 26, 1996, using the VSS, a truck-based sampling method using a heated probe; and the ISVS with and without particulate prefiltration.« less

  11. Determination of suspected allergens in cosmetic products by headspace-programmed temperature vaporization-fast gas chromatography-quadrupole mass spectrometry.

    PubMed

    del Nogal Sánchez, Miguel; Pérez-Pavón, José Luis; Moreno Cordero, Bernardo

    2010-07-01

    In the present work, a strategy for the qualitative and quantitative analysis of 24 volatile compounds listed as suspected allergens in cosmetics by the European Union is reported. The list includes benzyl alcohol, limonene, linalool, methyl 2-octynoate, beta-citronellol, geraniol, citral (two isomers), 7-hydroxycitronellal, anisyl alcohol, cinnamal, cinnamyl alcohol, eugenol, isoeugenol (two isomers), coumarin, alpha-isomethyl ionone, lilial, alpha-amylcinnamal, lyral, alpha-amylcinnamyl alcohol, farnesol (three isomers), alpha-hexyl cinnamal, benzyl cinnamate, benzyl benzoate, and benzyl salicylate. The applicability of a headspace (HS) autosampler in combination with a gas chromatograph (GC) equipped with a programmable temperature vaporizer (PTV) and a quadrupole mass spectrometry (qMS) detector is explored. By using a headspace sampler, sample preparation is reduced to introducing the sample into the vial. This reduces the analysis time and the experimental errors associated with this step of the analytical process. Two different injection techniques were used: solvent-vent injection and hot-split injection. The first offers a way to improve sensitivity at the same time maintaining the simple headspace instrumentation and it is recommended for compounds at trace levels. The use of a liner packed with Tenax-TA allowed the compounds of interest to be retained during the venting process. The signals obtained when hot-split injection was used allowed quantification of all the compounds according to the thresholds of the European Cosmetics Directive. Monodimensional gas chromatography coupled to a conventional quadrupole mass spectrometry detector was used and the 24 analytes were separated appropriately along a run time of about 12 min. Use of the standard addition procedure as a quantification technique overcame the matrix effect. It should be emphasized that the method showed good precision and accuracy. Furthermore, it is rapid, simple, and--in view of the

  12. Headspace Theater: An Innovative Method for Experiential Learning of Psychiatric Symptomatology Using Modified Role-Playing and Improvisational Theater Techniques

    ERIC Educational Resources Information Center

    Ballon, Bruce C.; Silver, Ivan; Fidler, Donald

    2007-01-01

    Objective: Headspace Theater has been developed to allow small group learning of psychiatric conditions by creating role-play situations in which participants are placed in a scenario that simulates the experience of the condition. Method: The authors conducted a literature review of role-playing techniques, interactive teaching, and experiential…

  13. Hydride Generation for Headspace Solid-Phase Extraction with CdTe Quantum Dots Immobilized on Paper for Sensitive Visual Detection of Selenium.

    PubMed

    Huang, Ke; Xu, Kailai; Zhu, Wei; Yang, Lu; Hou, Xiandeng; Zheng, Chengbin

    2016-01-05

    A low-cost, simple, and highly selective analytical method was developed for sensitive visual detection of selenium in human urine both outdoors and at home, by coupling hydride generation with headspace solid-phase extraction using quantum dots (QDs) immobilized on paper. The visible fluorescence from the CdTe QDs immobilized on paper was quenched by H2Se from hydride generation reaction and headspace solid-phase extraction. The potential mechanism was investigated by using X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) as well as Density Functional Theory (DFT). Potential interferences from coexisting ions, particularly Ag(+), Cu(2+), and Zn(2+), were eliminated. The selectivity was significantly increased because the selenium hydride was effectively separated from sample matrices by hydride generation. Moreover, due to the high sampling efficiency of hydride generation and headspace solid phase extraction, the sensitivity and the limit of detection (LOD) were significantly improved compared to conventional methods. A LOD of 0.1 μg L(-1) and a relative standard deviation (RSD, n = 7) of 2.4% at a concentration of 20 μg L(-1) were obtained when using a commercial spectrofluorometer as the detector. Furthermore, a visual assay based on the proposed method was developed for the detection of Se, 5 μg L(-1) of selenium in urine can be discriminated from the blank solution with the naked eye. The proposed method was validated by analysis of certified reference materials and human urine samples with satisfactory results.

  14. Measurement of activity coefficients of mixtures by head-space gas chromatography: general procedure.

    PubMed

    Luis, Patricia; Wouters, Christine; Van der Bruggen, Bart; Sandler, Stanley I

    2013-08-09

    Head-space gas chromatography (HS-GC) is an applicable method to perform vapor-liquid equilibrium measurements and determine activity coefficients. However, the reproducibility of the data may be conditioned by the experimental procedure concerning to the automated pressure-balanced system. The study developed in this work shows that a minimum volume of liquid in the vial is necessary to ensure the reliability of the activity coefficients since it may become a parameter that influences the magnitude of the peak areas: the helium introduced during the pressurization step may produce significant variations of the results when too small volume of liquid is selected. The minimum volume required should thus be evaluated prior to obtain experimentally the concentration in the vapor phase and the activity coefficients. In this work, the mixture acetonitrile-toluene is taken as example, requiring a sample volume of more than 5mL (about more than 25% of the vial volume). The vapor-liquid equilibrium and activity coefficients of mixtures at different concentrations (0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 molar fraction) and four temperatures (35, 45, 55 and 70°C) have been determined. Relative standard deviations (RSD) lower than 5% have been obtained, indicating the good reproducibility of the method when a sample volume larger than 5mL is used. Finally, a general procedure to measure activity coefficients by means of pressure-balanced head-space gas chromatography is proposed. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Development of a novel ultrasound-assisted headspace liquid-phase microextraction and its application to the analysis of chlorophenols in real aqueous samples.

    PubMed

    Xu, Hui; Liao, Ying; Yao, Jinrong

    2007-10-05

    A new sample pretreatment technique, ultrasound-assisted headspace liquid-phase microextraction was developed as mentioned in this paper. In the technique, the volatile analytes were headspace extracted into a small drop of solvent, which suspended on the bottom of a cone-shaped PCR tube instead of the needle tip of a microsyringe. More solvent could be suspended in the PCR tube than microsyringe due to the larger interfacial tension, thus the analysis sensitivity was significantly improved with the increase of the extractant volume. Moreover, ultrasound-assisted extraction and independent controlling temperature of the extractant and the sample were performed to enhance the extraction efficiency. Following the extraction, the solvent-loaded sample was analyzed by high-performance liquid chromatography. Chlorophenols (2-chlorophenol, 2,4-dichlorophenol and 2,6-dichlorophenol) were chosen as model analytes to investigate the feasibility of the method. The experimental conditions related to the extraction efficiency were systematically studied. Under the optimum experimental conditions, the detection limit (S/N=3), intra- and inter-day RSD were 6 ng mL(-1), 4.6%, 3.9% for 2-chlorophenol, 12 ng mL(-1), 2.4%, 8.8% for 2,4-dichlorophenol and 23 ng mL(-1), 3.3%, 5.3% for 2,6-dichlorophenol, respectively. The proposed method was successfully applied to determine chlorophenols in real aqueous samples. Good recoveries ranging from 84.6% to 100.7% were obtained. In addition, the extraction efficiency of our method and the conventional headspace liquid-phase microextraction were compared; the extraction efficiency of the former was about 21 times higher than that of the latter. The results demonstrated that the proposed method is a promising sample pretreatment approach, its advantages over the conventional headspace liquid-phase microextraction include simple setup, ease of operation, rapidness, sensitivity, precision and no cross-contamination. The method is very suitable

  16. Alternate paddle configuration for improved wear resistance in the saltstone mixer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reigel, M.; Fowley, M.

    The Saltstone Production Facility has a 10-inch Readco-Kurimoto continuous mixer that mixes the premix dry feeds and low-level waste salt solution to make fresh (uncured) saltstone. Inspection of the mixer in January 2013 showed significant wear on the third, fourth and fifth paddle pairs after the conveying augers. A 2-inch Readco-Kurimoto continuous mixer was used to test alternate paddle configurations for use in the 10-inch mixer to decrease the wear rate on the paddles. Two wear tests were conducted to investigate a method of reducing wear on the mixer paddles. The first test (wear test 2a) had a paddle configurationmore » similar to the currently installed 10-inch mixer in the SPF. This test established baseline wear. The second test (wear test 2b) had a reconfigured paddle arrangement that replaced the flat paddles with helical paddles for paddle pairs 2 - 6 and aligned paddle pair 1 with the augers. The intent of the reconfiguration was to more effectively convey the partially wetted dry feeds through the transition region and into the liquid feed where paddle wear is reduced due to dry feeds and salt solution being mixed at the intended water to premix ratio. The design of the helical paddles provides conveyance through the transition region to the liquid feed inlet. The alignment with the auger is aimed to provide a smoother transition (minimizing the discontinuity between the auger and paddle pair 1) into the downstream paddles. A soft metal with low wear resistance (6000 series aluminum) was used for the wear testing paddles to determine wear patterns while minimizing run time and maximizing wear rate. For the two paddle configurations tested using the scaled 2-inch Readco-Kurimoto continuous mixer, with the first six paddles after the augers replaced by the wear paddles and the remaining paddles were stainless steel. Since the 10-inch SPF mixer is designed with the liquid inlet centered over paddle pairs 5 and 6, the scaled 2-inch mixer was

  17. Identification of Volatile Flavor Components by Headspace Analysis: A Quick and Easy Experiment for Introducing GC/MS

    NASA Astrophysics Data System (ADS)

    Kjonaas, Richard; Soller, Jean L.; McCoy, Leslee A.

    1997-09-01

    By placing a piece of chewing gum (Wrigley's) or a crushed piece of hard candy (LifeSavers or Runts) into a vial, followed by GC/MS analysis of a five microliter sample of the headspace, students are able to identify several of the volatile flavoring components which are present. The experiment has been used successfully with sophomore organic chemistry students, and with visiting groups of talented high school students over a three year period. Identification is simplified by handing out a list of the structural formulas of some likely candidates. Some of the components that these students easily identity include ethyl acetate, isobutyl acetate, isoamyl acetate, ethyl butyrate, benzaldehyde, benzyl alcohol, limonene, and cinnamaldehyde. Some of the more difficult to identify components include menthol, menthone, carvone, cineole, myrcene, alpha-pinene, beta-pinene, para-cymene, and gama-terpinene. Most of the major headspace components give signals whose size is comparable to that of the carbon dioxide which is present in each injection. Even with split injection, the background noise is trivial compared to the signals from the major components. The experiments were carried out with a commercially available tabletop GC/MS (Varian 3400 with Saturn MS).

  18. Determination of the content of alkyl ketene dimer in its latex by an ionic-liquid assisted headspace gas chromatography.

    PubMed

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan; Chen, Chun-Xia

    2017-12-29

    This paper reports on an ionic-liquid assisted headspace gas chromatographic (HS-GC) for the determination of the content of alkyl ketene dimer (AKD) in its latex samples, in which the GC system was equipped with a thermal conductivity detector (TCD). The method was based on the AKD hydrolysis conducted in 1-butyl-3-methylimidazolium chloride (ionic-liquid) added medium at 100°C for 10min in a closed headspace sample vial, and the measured CO 2 (the resulting product of the hydrolysis) by HS-GC. The results showed that the present method has a good measurement precision (RSD <2.3%) and accuracy (recoveries from 96 - 105%), and the limit of quantitation (LOQ) is 0.9%. The present method is very suitable to be used for the routine check of AKD content in its latex sample in mill applications. The study also showed that the content of AKD in the tested commercial latex samples were in the range of 3.5-12%. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. [Headspace analysis of volatile organic compounds (VOC) in drinking water by the method of gas chromatography].

    PubMed

    Sotnikov, E E; Zagaynov, V F; Mikhaylova, R I; Milochkin, D A; Ryzhova, I N; Kornilov, I O

    2014-01-01

    In the paper there is presented a methodology of analysis of headspace 52 volatile organic compounds in drinking water by the method of gas chromatography with the use of the chromatograph "Crystal 5000.2" with three detectors and automatic attachment Lab Hut 200N NT-200 for the preparation of the sample water and vapor phase input. The lower limit of detection for all compounds in the 2-10 times lower than that of the corresponding standard value.

  20. Headspace Solid Phase Micro Extraction Gas Chromatographic Determination of Fenthion in Human Serum

    PubMed Central

    Kasiotis, Konstantinos M.; Souki, Helen; Tsakirakis, Angelos N.; Carageorgiou, Haris; Theotokatos, Spiridon A.; Haroutounian, Serkos A.; Machera, Kyriaki

    2008-01-01

    A simple and effective analytical procedure was developed for the determination of fenthion residues in human serum samples. The sample treatment was performed using the headspace solid-phase micro extraction with polyacrylate fiber, which has the advantage to require low amount of serum (1 mL) without tedious pre-treatment. The quantification of fenthion was carried out by gas chromatography-mass spectrometry and the recoveries ranged from 79 to 104% at two spiking levels for 6 replicates. Detection and quantification limits were calculated as 1.51 and 4.54 ng/mL of serum respectively. Two fenthion metabolites fenoxon and fenthion–sulfoxide were also identified. PMID:19325792

  1. Determination of arsenic and selenium by hydride generation and headspace solid phase microextraction coupled with optical emission spectrometry

    NASA Astrophysics Data System (ADS)

    Tyburska, Anna; Jankowski, Krzysztof; Rodzik, Agnieszka

    2011-07-01

    A hydride generation headspace solid phase microextraction technique has been developed in combination with optical emission spectrometry for determination of total arsenic and selenium. Hydrides were generated in a 10 mL volume septum-sealed vial and subsequently collected onto a polydimethylsiloxane/Carboxen solid phase microextraction fiber from the headspace of sample solution. After completion of the sorption, the fiber was transferred into a thermal desorption unit and the analytes were vaporized and directly introduced into argon inductively coupled plasma or helium microwave induced plasma radiation source. Experimental conditions of hydride formation reaction as well as sorption and desorption of analytes have been optimized showing the significant effect of the type of the solid phase microextraction fiber coating, the sorption time and hydrochloric acid concentration of the sample solution on analytical characteristics of the method developed. The limits of detection of arsenic and selenium were 0.1 and 0.8 ng mL - 1 , respectively. The limit of detection of selenium could be improved further using biosorption with baker's yeast Saccharomyces cerevisiae for analyte preconcentration. The technique was applied for the determination of total As and Se in real samples.

  2. The influence of headspace and dissolved oxygen level on growth and haemolytic BL enterotoxin production of a psychrotolerant Bacillus weihenstephanensis isolate on potato based ready-to-eat food products.

    PubMed

    Samapundo, S; Everaert, H; Wandutu, J N; Rajkovic, A; Uyttendaele, M; Devlieghere, F

    2011-04-01

    The major objective of this study was to determine the influence of the initial headspace and dissolved O(2) level and vacuum packaging on growth and diarrhoeal enterotoxin production by Bacillus weihenstephanensis on potato based ready-to-eat food products. In general, the lower the initial headspace or dissolved O(2) level the slower the maximum growth rate (μ(max), log(10) CFU g(-1) d(-1)), the longer the lag phase duration (λ, d) and the smaller the maximum population density (N(max), log(10) CFU g(-1)) became. The slowest μ(max), the longest λ and the smallest N(max) were generally found for growth under vacuum packaging. This implies shorter shelf-lives will occur at higher initial headspace or dissolved O(2) levels as the growth of B. weihenstephanensis to the infective dose of 10(5) CFU g(-1) in such atmospheres takes a shorter time. Significant consumption of dissolved O(2) only occurred when growth shifted from the lag to the exponential phase and growth generally transitioned from the exponential to the stationary phase when the dissolved O(2) levels fell below ca. 75 ppb. Diarrhoeal enterotoxin production (determined via detection of the L2 component of haemolytic BL) was similar for growth under initial headspace O(2) levels of 1-20.9%, and was only reduced when growth took place under vacuum packaging. The reduction in L2 production when growth took place under vacuum was most probably related to the low final cell densities observed under this condition. Both growth and L2 production were inhibited over a 32-day incubation period at 7 °C by 40% CO(2) irrespective of the headspace or dissolved O(2) levels. The results illustrate the importance of residual O(2) and CO(2) on the shelf-stability and safety of modified atmosphere packaged potato based ready-to-eat food products with regards to B. weihenstephanensis. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Multivariate analysis of the volatile components in tobacco based on infrared-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Yang, Yanqin; Pan, Yuanjiang; Zhou, Guojun; Chu, Guohai; Jiang, Jian; Yuan, Kailong; Xia, Qian; Cheng, Changhe

    2016-11-01

    A novel infrared-assisted extraction coupled to headspace solid-phase microextraction followed by gas chromatography with mass spectrometry method has been developed for the rapid determination of the volatile components in tobacco. The optimal extraction conditions for maximizing the extraction efficiency were as follows: 65 μm polydimethylsiloxane-divinylbenzene fiber, extraction time of 20 min, infrared power of 175 W, and distance between the infrared lamp and the headspace vial of 2 cm. Under the optimum conditions, 50 components were found to exist in all ten tobacco samples from different geographical origins. Compared with conventional water-bath heating and nonheating extraction methods, the extraction efficiency of infrared-assisted extraction was greatly improved. Furthermore, multivariate analysis including principal component analysis, hierarchical cluster analysis, and similarity analysis were performed to evaluate the chemical information of these samples and divided them into three classifications, including rich, moderate, and fresh flavors. The above-mentioned classification results were consistent with the sensory evaluation, which was pivotal and meaningful for tobacco discrimination. As a simple, fast, cost-effective, and highly efficient method, the infrared-assisted extraction coupled to headspace solid-phase microextraction technique is powerful and promising for distinguishing the geographical origins of the tobacco samples coupled to suitable chemometrics. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Multi-Component Profiling of Trace Volatiles in Blood by Gas Chromatography/Mass Spectrometry with Dynamic Headspace Extraction

    PubMed Central

    Kakuta, Shoji; Yamashita, Toshiyuki; Nishiumi, Shin; Yoshida, Masaru; Fukusaki, Eiichiro; Bamba, Takeshi

    2015-01-01

    A dynamic headspace extraction method (DHS) with high-pressure injection is described. This dynamic extraction method has superior sensitivity to solid phase micro extraction, SPME and is capable of extracting the entire gas phase by purging the headspace of a vial. Optimization of the DHS parameters resulted in a highly sensitive volatile profiling system with the ability to detect various volatile components including alcohols at nanogram levels. The average LOD for a standard volatile mixture was 0.50 ng mL−1, and the average LOD for alcohols was 0.66 ng mL−1. This method was used for the analysis of volatile components from biological samples and compared with acute and chronic inflammation models. The method permitted the identification of volatiles with the same profile pattern as in vitro oxidized lipid-derived volatiles. In addition, the concentration of alcohols and aldehydes from the acute inflammation model samples were significantly higher than that for the chronic inflammation model samples. The different profiles between these samples could also be identified by this method. Finally, it was possible to analyze alcohols and low-molecular-weight volatiles that are difficult to analyze by SPME in high sensitivity and to show volatile profiling based on multi-volatile simultaneous analysis. PMID:26819905

  5. Multi-Component Profiling of Trace Volatiles in Blood by Gas Chromatography/Mass Spectrometry with Dynamic Headspace Extraction.

    PubMed

    Kakuta, Shoji; Yamashita, Toshiyuki; Nishiumi, Shin; Yoshida, Masaru; Fukusaki, Eiichiro; Bamba, Takeshi

    2015-01-01

    A dynamic headspace extraction method (DHS) with high-pressure injection is described. This dynamic extraction method has superior sensitivity to solid phase micro extraction, SPME and is capable of extracting the entire gas phase by purging the headspace of a vial. Optimization of the DHS parameters resulted in a highly sensitive volatile profiling system with the ability to detect various volatile components including alcohols at nanogram levels. The average LOD for a standard volatile mixture was 0.50 ng mL(-1), and the average LOD for alcohols was 0.66 ng mL(-1). This method was used for the analysis of volatile components from biological samples and compared with acute and chronic inflammation models. The method permitted the identification of volatiles with the same profile pattern as in vitro oxidized lipid-derived volatiles. In addition, the concentration of alcohols and aldehydes from the acute inflammation model samples were significantly higher than that for the chronic inflammation model samples. The different profiles between these samples could also be identified by this method. Finally, it was possible to analyze alcohols and low-molecular-weight volatiles that are difficult to analyze by SPME in high sensitivity and to show volatile profiling based on multi-volatile simultaneous analysis.

  6. Determination of dissolved methane in natural waters using headspace analysis with cavity ring-down spectroscopy.

    PubMed

    Roberts, Hannah M; Shiller, Alan M

    2015-01-26

    Methane (CH4) is the third most abundant greenhouse gas (GHG) but is vastly understudied in comparison to carbon dioxide. Sources and sinks to the atmosphere vary considerably in estimation, including sources such as fresh and marine water systems. A new method to determine dissolved methane concentrations in discrete water samples has been evaluated. By analyzing an equilibrated headspace using laser cavity ring-down spectroscopy (CRDS), low nanomolar dissolved methane concentrations can be determined with high reproducibility (i.e., 0.13 nM detection limit and typical 4% RSD). While CRDS instruments cost roughly twice that of gas chromatographs (GC) usually used for methane determination, the process presented herein is substantially simpler, faster, and requires fewer materials than GC methods. Typically, 70-mL water samples are equilibrated with an equivalent amount of zero air in plastic syringes. The equilibrated headspace is transferred to a clean, dry syringe and then drawn into a Picarro G2301 CRDS analyzer via the instrument's pump. We demonstrate that this instrument holds a linear calibration into the sub-ppmv methane concentration range and holds a stable calibration for at least two years. Application of the method to shipboard dissolved methane determination in the northern Gulf of Mexico as well as river water is shown. Concentrations spanning nearly six orders of magnitude have been determined with this method. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. An ionic liquid as a solvent for headspace single drop microextraction of chlorobenzenes from water samples.

    PubMed

    Vidal, Lorena; Psillakis, Elefteria; Domini, Claudia E; Grané, Nuria; Marken, Frank; Canals, Antonio

    2007-02-12

    A headspace single-drop microextraction (HS-SDME) procedure using room temperature ionic liquid and coupled to high-performance liquid chromatography capable of quantifying trace amounts of chlorobenzenes in environmental water samples is proposed. A Plackett-Burman design for screening was carried out in order to determine the significant experimental conditions affecting the HS-SDME process (namely drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time and temperature), and then a central composite design was used to optimize the significant conditions. The optimum experimental conditions found from this statistical evaluation were: a 5 microL microdrop of 1-butyl-3-methylimidazolium hexafluorophosphate, exposed for 37 min to the headspace of a 10 mL aqueous sample placed in a 15 mL vial, stirred at 1580 rpm at room temperature and containing 30% (w/v) NaCl. The calculated calibration curves gave a high level of linearity for all target analytes with correlation coefficients ranging between 0.9981 and 0.9997. The repeatability of the proposed method, expressed as relative standard deviation, varied between 1.6 and 5.1% (n=5). The limits of detection ranged between 0.102 and 0.203 microg L(-1). Matrix effects upon extraction were evaluated by analysing spiked tap and river water as well as effluent water samples originating from a municipal wastewater treatment plant.

  8. Dynamic collection and analysis of volatile organic compounds from the headspace of cell cultures.

    PubMed

    Baranska, A; Smolinska, A; Boots, A W; Dallinga, J W; van Schooten, F J

    2015-10-15

    Exhaled breath has proven to be a valuable source of information about human bodies. Subtle differences between volatile organic compounds (VOCs) formed endogenously can be detected and become a base for a potential monitoring tool for health and disease. Until now, there has been a lack of biological and mechanistic knowledge of the processes involved in the production of relevant VOCs. Among the possible sources of health-related and disease-related VOCs are microorganisms found in the respiratory tract and in the gut. Other VOCs in the body are produced by cells that are influenced by the disease, for instance, due to metabolic disorders and/or inflammation. To gain insight into the in vivo production of VOCs by human cells and thus the exhaled breath composition, in vitro experiments involving relevant cells should be studied because they may provide valuable information on the production of VOCs by the affected cells. To this aim we developed and validated a system for dynamically (continuously) collecting headspace air in vitro using a Caco-2 cell line. The system allows the application of different cell lines as well as different experimental setups, including varying exposure times and treatment options while preserving cell viability. Significant correlation (p  ⩽  0.0001) between collection outputs within each studied group confirmed high reproducibility of the collection system. An example of such an application is presented here. We studied the influence of oxidative stress on the VOC composition of the headspace air of Caco-2 cells. By comparing the VOC composition of air flushed through empty culture flasks (n  =  35), flasks with culture medium (n  =  35), flasks with medium and cells (n  =  20), flasks with medium and an oxidative stressor (H2O2) (n  =  20), and flasks with medium, stressor, and cells (n  =  20), we were able to separate the effects from the stressor on the cells from all other

  9. Diagnosing gastrointestinal illnesses using fecal headspace volatile organic compounds

    PubMed Central

    Chan, Daniel K; Leggett, Cadman L; Wang, Kenneth K

    2016-01-01

    Volatile organic compounds (VOCs) emitted from stool are the components of the smell of stool representing the end products of microbial activity and metabolism that can be used to diagnose disease. Despite the abundance of hydrogen, carbon dioxide, and methane that have already been identified in human flatus, the small portion of trace gases making up the VOCs emitted from stool include organic acids, alcohols, esters, heterocyclic compounds, aldehydes, ketones, and alkanes, among others. These are the gases that vary among individuals in sickness and in health, in dietary changes, and in gut microbial activity. Electronic nose devices are analytical and pattern recognition platforms that can utilize mass spectrometry or electrochemical sensors to detect these VOCs in gas samples. When paired with machine-learning and pattern recognition algorithms, this can identify patterns of VOCs, and thus patterns of smell, that can be used to identify disease states. In this review, we provide a clinical background of VOC identification, electronic nose development, and review gastroenterology applications toward diagnosing disease by the volatile headspace analysis of stool. PMID:26819529

  10. Investigations on the emission of fragrance allergens from scented toys by means of headspace solid-phase microextraction gas chromatography-mass spectrometry.

    PubMed

    Masuck, Ines; Hutzler, Christoph; Luch, Andreas

    2010-04-30

    In the revised European toy safety directive 2009/48/EC the application of fragrance allergens in children's toys is restricted. The focus of the present work lies on the instrumental analytics of 13 banned fragrance allergens, as well as on 11 fragrance allergens that require declaration when concentrations surpass 100 microg per gram material. Applying a mixture of ethyl acetate and toluene solid/liquid extraction was performed prior to quantitative analysis of mass contents of fragrances in scented toys. In addition, an easy-to-perform method for the determination of emitted fragrances at 23 degrees C (handling conditions) or at 40 degrees C (worst case scenario) has been worked out to allow for the evaluation of potential risks originating from inhalation of these compounds during handling of or playing with toys. For this purpose a headspace solid-phase microextraction (HS-SPME) technique was developed and coupled to subsequent gas chromatography-mass spectrometry (GC-MS) analysis. Fragrance allergens were adsorbed (extracted) from the gas phase onto an 85 microm polyacrylate fiber while incubating pieces of the scented toys in sealed headspace vials at 23 degrees C and 40 degrees C. Quantification of compounds was performed via external calibration. The newly developed headspace method was subsequently applied to five perfumed toys. As expected, the emission of fragrance allergens from scented toys depends on the temperature and on the content of fragrance allergens present in those samples. In particular at conditions mimicking worst case (40 degrees C), fragrance allergens in toys may pose a risk to children since considerable amounts of compound might be absorbed by lung tissue via breathing of contaminated air. 2010 Elsevier B.V. All rights reserved.

  11. Review of Mass Spectrometry Data from Waste Tank Headspace Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sklarew, Debbie S.; Mitroshkov, Alexandre V.

    2006-02-28

    Numerous analytes have been categorized as tentatively identified compounds (TICs) in air samples from the headspaces of the Hanford Site high-level radioactive waste tanks. The tentative identification of these compounds was based mainly on the agreement between the observed mass spectra and a library of published mass spectra with consideration given to the gas chromatographic conditions and retention times. Many of the TICs were found in a limited number of tanks, were identified by only one laboratory or by one method, and/or were thought to be unlikely components of the waste or its degradation products. Consequently, the mass spectra ofmore » selected analytes have been reviewed to determine if their tentative identifications were correct. From our current review of 49 TICs, we found 25 that were misidentified and recommend that 54 of the associated results be flagged as suspect and 22 of the associated results be assigned a different compound name.« less

  12. Determination of Residual Solvents in Linezolid by Static Headspace GC

    PubMed Central

    Feng, Xiao-Zhen; Han, Guo-Cheng; Qin, Jianhe; Yin, Shi-min; Chen, Zhencheng

    2016-01-01

    A headspace gas chromatographic method was developed for the determination of residual solvents in linezolid active substances. The solvents include petroleum ether (60–90°C), acetone, tetrahydrofuran, ethyl acetate, methanol, dichloromethane (DCM) and pyridine. The method showed the possibility to detect the tested solvents with a linear determination correlation coefficient (r) greater than 0.9995 except for petroleum ether (0.9980). The limits of detection ranged between 0.12 μg/mL (petroleum ether) and 3.56 μg/mL (DCM), and the limits of quantity ranged between 0.41 μg/mL (petroleum ether) and 11.86 μg/mL (DCM). The method achieved good accuracy (recoveries ranging from 92.8 to 102.5%) and precision for both run-to-run and day-to-day assay (relative standard deviation ranging from 0.4 to 1.3%) for all seven solvents concerned, which were applied in the quality control of three batches of linezolid successfully. PMID:26657409

  13. Sensor for headspace pressure and H2O concentration measurements in closed vials by tunable diode laser absorption spectroscopy

    NASA Astrophysics Data System (ADS)

    Cai, Tingdong; Wang, Guishi; Cao, Zhensong; Zhang, Weijun; Gao, Xiaoming

    2014-07-01

    The concentration of H2O and the pressure in the headspace of vials are simultaneously measured by a tunable diode laser sensor based on absorption spectroscopy techniques. The 7168.437 cm-1 spectral line of H2O is chosen as the sensing transition for its strong absorption strength and being reasonably far away from its neighboring molecular transitions. In order to prevent interference absorption by ambient water vapor in the room air, a difference between the measured signal and the referenced signal is used to calculate the pressure and H2O concentration in the headspace of vials, eliminating the need for inert gas purges and calibration with known gas. The validation of the sensor is conducted in a static vial, yielding an accuracy of 1.23% for pressure and 3.81% for H2O concentration. The sensitivity of the sensor is estimated to be about 2.5 Torr for pressure and 400 ppm for H2O concentration over a 3 cm absorption path length respectively. Accurate measurements for commercial freeze-dried products demonstrate the in-line applications of the sensor for the pharmaceutical industry.

  14. A novel method for rapid determination of total solid content in viscous liquids by multiple headspace extraction gas chromatography.

    PubMed

    Xin, Li-Ping; Chai, Xin-Sheng; Hu, Hui-Chao; Barnes, Donald G

    2014-09-05

    This work demonstrates a novel method for rapid determination of total solid content in viscous liquid (polymer-enriched) samples. The method is based multiple headspace extraction gas chromatography (MHE-GC) on a headspace vial at a temperature above boiling point of water. Thus, the trend of water loss from the tested liquid due to evaporation can be followed. With the limited MHE-GC testing (e.g., 5 extractions) and a one-point calibration procedure (i.e., recording the weight difference before and after analysis), the total amount of water in the sample can be determined, from which the total solid contents in the liquid can be calculated. A number of black liquors were analyzed by the new method which yielded results that closely matched those of the reference method; i.e., the results of these two methods differed by no more than 2.3%. Compared with the reference method, the MHE-GC method is much simpler and more practical. Therefore, it is suitable for the rapid determination of the solid content in many polymer-containing liquid samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Validation of a headspace trap gas chromatography and mass spectrometry method for the quantitative analysis of volatile compounds from degraded rapeseed oil.

    PubMed

    Sghaier, Lilia; Cordella, Christophe B Y; Rutledge, Douglas N; Watiez, Mickaël; Breton, Sylvie; Sassiat, Patrick; Thiebaut, Didier; Vial, Jérôme

    2016-05-01

    Due to lipid oxidation, off-flavors, characterized by a fishy odor, are emitted during the heating of rapeseed oil in a fryer and affect the flavor of rapeseed oil even at low concentrations. Thus, there is a need for analytical methods to identify and quantify these products. To study the headspace composition of degraded rapeseed oil, and more specifically the compounds responsible for the fishy odor, a headspace trap gas chromatography with mass spectrometry method was developed and validated. Six volatile compounds formed during the degradation of rapeseed oil were quantified: 1-penten-3-one, (Z)-4-heptenal, hexanal, nonanal, (E,E)-heptadienal, and (E)-2-heptenal. Validation using accuracy profiles allowed us to determine the valid ranges of concentrations for each compound, with acceptance limits of 40% and tolerance limits of 80%. This method was then successfully applied to real samples of degraded oils. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Derivatization coupled to headspace programmed-temperature vaporizer gas chromatography with mass spectrometry for the determination of amino acids: Application to urine samples.

    PubMed

    González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo

    2016-09-01

    A new method based on headspace programmed-temperature vaporizer gas chromatography with mass spectrometry has been developed and validated for the determination of amino acids (alanine, sarcosine, ethylglycine, valine, leucine, and proline) in human urine samples. Derivatization with ethyl chloroformate was employed successfully to determine the amino acids. The derivatization reaction conditions as well as the variables of the headspace sampling were optimized. The existence of a matrix effect was checked and the analytical characteristics of the method were determined. The limits of detection were 0.15-2.89 mg/L, and the limits of quantification were 0.46-8.67 mg/L. The instrumental repeatability was 1.6-11.5%. The quantification of the amino acids in six urine samples from healthy subjects was performed with the method developed with the one-point standard additions protocol, with norleucine as the internal standard. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Headspace single drop microextraction coupled with microwave extraction of essential oil from plant materials.

    PubMed

    Zhai, Yujuan; Sun, Shuo; Wang, Ziming; Zhang, Yupu; Liu, He; Sun, Ye; Zhang, Hanqi; Yu, Aimin

    2011-05-01

    Headspace single drop microextraction (HS-SDME) coupled with microwave extraction (ME) was developed and applied to the extraction of the essential oil from dried Syzygium aromaticum (L.) Merr. et Perry and Cuminum cyminum L. The operational parameters, such as microdrop volume, microwave absorption medium (MAM), extraction time, and microwave power were optimized. Ten microliters of decane was used as the microextraction solvent. Ionic liquid and carbonyl iron powder were used as MAM. The extraction time was less than 7 min at the microwave power of 440 W. The proposed method was compared with hydrodistillation (HD). There were no obvious differences in the constituents of essential oils obtained by the two methods.

  18. An innovative online VFA monitoring system for the anerobic process, based on headspace gas chromatography.

    PubMed

    Boe, Kanokwan; Batstone, Damien John; Angelidaki, Irini

    2007-03-01

    A new method for online measurement of volatile fatty acids (VFA) in anerobic digesters has been developed based on headspace gas chromatography (HSGC). The method applies ex situ VFA stripping with variable headspace volume and gas analysis by gas chromatography-flame ionization detection (GC-FID). In each extraction, digester sample was acidified with H(3)PO(4) and NaHSO(4), then heated to strip the VFA into the gas phase. The gas was sampled in a low friction glass syringe before injected into the GC for measurement. The system has been tested for online monitoring of a lab-scale CSTR reactor treating manure for more than 6 months and has shown good agreement with off-line analysis. The system is capable of measuring individual VFA components. This is of advantage since specific VFA components such as propionic and butyric acid can give extra information about the process status. Another important advantage of this sensor is that there is no filtration, which makes possible application in high solids environments. The system can thus be easily applied in a full-scale biogas reactor by connecting the system to the liquid circulation loop to obtain fresh sample from the reactor. Local calibration is needed but automatic calibration is also possible using standard addition method. Sampling duration is 25-40 min, depending on the washing duration, and sensor response is 10 min. This is appropriate for full-scale reactors, since dynamics within most biogas reactors are of the order of several hours.

  19. Literature review of the potential impact of glycolic acid on the technetium chemistry of srs tank waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, Charles A.; McCabe, Daniel J.

    This document presents a literature study of the impact of glycolate on technetium chemistry in the Savannah River Site (SRS) waste system and specifically Saltstone. A predominant portion of the Tc at SRS will be sent to the Saltstone Facility where it will be immobilized. The Tc in the tank waste is in the highly soluble chemical form of pertechnetate ion (TcO 4 -) which is reduced by blast furnace slag (BFS) in Saltstone, rendering it highly insoluble and resistant to leaching.

  20. Identification of terpenes and essential oils by means of static headspace gas chromatography-ion mobility spectrometry.

    PubMed

    Rodríguez-Maecker, Roman; Vyhmeister, Eduardo; Meisen, Stefan; Rosales Martinez, Antonio; Kuklya, Andriy; Telgheder, Ursula

    2017-11-01

    Static headspace gas chromatography-ion mobility spectrometry (SHS GC-IMS) is a relatively new analytical technique that has considerable potential for analysis of volatile organic compounds (VOCs). In this study, SHS GC-IMS was used for the identification of the major terpene components of various essential oils (EOs). Based on the data obtained from 25 terpene standards and 50 EOs, a database for fingerprint identification of characteristic terpenes and EOs was generated utilizing SHS GC-IMS for authenticity testing of fragrances in foods, cosmetics, and personal care products. This database contains specific normalized IMS drift times and GC retention indices for 50 terpene components of EOs. Initially, the SHS GC-IMS parameters, e.g., drift gas and carrier gas flow rates, drift tube, and column temperatures, were evaluated to determine suitable operating conditions for terpene separation and identification. Gas chromatography-mass spectrometry (GC-MS) was used as a reference method for the identification of terpenes in EOs. The fingerprint pattern based on the normalized IMS drift times and retention indices of 50 terpenes is presented for 50 EOs. The applicability of the method was proven on examples of ten commercially available food, cosmetic, and personal care product samples. The results confirm the suitability of SHS GC-IMS as a powerful analytical technique for direct identification of terpene components in solid and liquid samples without any pretreatment. Graphical abstract Fingerprint pattern identification of terpenes and essential oils using static headspace gas chromatography-ion mobility spectrometry.

  1. Headspace screening of fluid obtained from the gut during colonoscopy and breath analysis by proton transfer reaction-mass spectrometry: A novel approach in the diagnosis of gastro-intestinal diseases

    NASA Astrophysics Data System (ADS)

    Lechner, M.; Colvin, H. P.; Ginzel, C.; Lirk, P.; Rieder, J.; Tilg, H.

    2005-05-01

    Background: The diagnosis of many gastro-intestinal diseases is difficult and can often be confirmed only by using invasive diagnostic means. In contrast, the headspace screening of fluid obtained from the gut during colonoscopy and the analysis of exhaled air may be a novel approach for the diagnosis of these diseases.Materials and methods: The screening was performed by using proton transfer reaction-mass spectrometry (PTR-MS) which allows rapid and sensitive measurement. Fluid samples obtained from the gut during colonoscopy were collected from 76 and breath samples from 70 subjects. Mass spectra of healthy controls were created. Afterwards these spectra were compared with those of patients suffering from inflammatory bowel diseases (IBD; Crohn's disease and ulcerative colitis; n = 10) and irritable bowel syndrome (IBS; n = 7).Results: Significant differences in the mass spectra could be observed both in the headspace of the fluid and in the exhaled air comparing patients with healthy controls.Conclusions: This study is the first describing headspace screening of fluid obtained from the gut during colonoscopy, possibly presenting a novel diagnostic tool in the differential diagnosis of gastro-intestinal diseases.

  2. Monitoring gas-phase CO2 in the headspace of champagne glasses through combined diode laser spectrometry and micro-gas chromatography analysis.

    PubMed

    Moriaux, Anne-Laure; Vallon, Raphaël; Parvitte, Bertrand; Zeninari, Virginie; Liger-Belair, Gérard; Cilindre, Clara

    2018-10-30

    During Champagne or sparkling wine tasting, gas-phase CO 2 and volatile organic compounds invade the headspace above glasses, thus progressively modifying the chemical space perceived by the consumer. Gas-phase CO 2 in excess can even cause a very unpleasant tingling sensation perturbing both ortho- and retronasal olfactory perception. Monitoring as accurately as possible the level of gas-phase CO 2 above glasses is therefore a challenge of importance aimed at better understanding the close relationship between the release of CO 2 and a collection of various tasting parameters. Here, the concentration of CO 2 found in the headspace of champagne glasses served under multivariate conditions was accurately monitored, all along the 10 min following pouring, through a new combined approach by a CO 2 -Diode Laser Sensor and micro-gas chromatography. Our results show the strong impact of various tasting conditions (volume dispensed, intensity of effervescence, and glass shape) on the release of gas-phase CO 2 above the champagne surface. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Headspace, volatile and semi-volatile organic compounds diversity and radical scavenging activity of ultrasonic solvent extracts from Amorpha fruticosa honey samples.

    PubMed

    Jerković, Igor; Marijanović, Zvonimir; Kezić, Janja; Gugić, Mirko

    2009-07-27

    Volatile organic compounds of Amorpha fruticosa honey samples were isolated by headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE), followed by gas chromatography and mass spectrometry analyses (GC, GC-MS), in order to obtain complementary data for overall characterization of the honey aroma. The headspace of the honey was dominated by 2-phenylethanol (38.3-58.4%), while other major compounds were trans- and cis-linalool oxides, benzaldehyde and benzyl alcohol. 2-Phenylethanol (10.5-16.8%) and methyl syringate (5.8-8.2%) were the major compounds of ultrasonic solvent extracts, with an array of small percentages of linalool, benzene and benzoic acid derivatives, aliphatic hydrocarbons and alcohols, furan derivatives and others. The scavenging ability of the series of concentrations of the honey ultrasonic solvent extracts and the corresponding honey samples was tested by a DPPH (1,1-diphenyl-2-picrylhydrazyl) assay. Approximately 25 times lower concentration ranges (up to 2 g/L) of the extracts exhibited significantly higher free radical scavenging potential with respect to the honey samples.

  4. Determination of maximal amount of minor gases adsorbed in a shale sample by headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Hu, Hui-Chao; Chai, Xin-Sheng; Pan, Lei; Xiao, Xian-Ming

    2014-02-07

    In this paper, we present a novel method for determining the maximal amount of ethane, a minor gas species, adsorbed in a shale sample. The method is based on the time-dependent release of ethane from shale samples measured by headspace gas chromatography (HS-GC). The study includes a mathematical model for fitting the experimental data, calculating the maximal amount gas adsorbed, and predicting results at other temperatures. The method is a more efficient alternative to the isothermal adsorption method that is in widespread use today. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Identification and quantification of odours from oxobiodegradable polyethylene oxidised under a free radical flow by headspace solid-phase microextraction followed by gas chromatography-olfactometry-mass spectrometry.

    PubMed

    Wrona, Magdalena; Vera, Paula; Pezo, Davinson; Nerín, Cristina

    2017-09-01

    Recently oxobiodegradable polyethylene gained popularity as food packaging material due to its potential to reduce polymer waste. However, this type of material can release after its oxidation off-odour compounds that affect the organoleptic properties of packaged food. Odour compounds released from both polyethylene and oxobiodegradable polyethylene before and after oxidation under a free radicals flow were investigated after 1 day, 2 days and 3 days of oxidation. The samples were analysed using headspace solid phase microextraction followed by gas chromatography-mass spectrometry and headspace solid phase microextraction coupled to gas chromatography-olfactometry-mass spectrometry. Sixty-two different odorous compounds were identified. 4-methylthio-2-butanone (fruit), nonanal (fat) and 3,6-nonadienal (fat) were present in different materials before oxidation. Multiple headspace-solid phase microextraction has been used to quantify all analytes. The most abundant compound was (Z)-3-hexenyl hexanoate with a concentration range between 1.5791±0.1387µg/g and 4.8181±0.3123µg/g. Compounds such as 2-dodecenal, 2-octenal, 2-pentanol, 3-nonenal, 3,6-nonadienal, ethyl 3-methylbutanoate, ethyl octenoate, hexanone, isopropyl hexanoate, octanal were below their LOD evaluated using MS detector; however, they were detected by gas chromatography-olfactometry. The minimum LOD and LOQ were 0.011µg/g and 0.036µg/g, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Headspace quantification of pure and aqueous solutions of binary mixtures of key volatile organic compounds in Swiss cheeses using selected ion flow tube mass spectrometry.

    PubMed

    Castada, Hardy Z; Wick, Cheryl; Harper, W James; Barringer, Sheryl

    2015-01-15

    Twelve volatile organic compounds (VOCs) have recently been identified as key compounds in Swiss cheese with split defects. It is important to know how these VOCs interact in binary mixtures and if their behavior changes with concentration in binary mixtures. Selected ion flow tube mass spectrometry (SIFT-MS) was used for the headspace analysis of VOCs commonly found in Swiss cheeses. Headspace (H/S) sampling and quantification checks using SIFT-MS and further linear regression analyses were carried out on twelve selected aqueous solutions of VOCs. Five binary mixtures of standard solutions of VOCs were also prepared and the H/S profile of each mixture was analyzed. A very good fit of linearity for the twelve VOCs (95% confidence level) confirms direct proportionality between the H/S and the aqueous concentration of the standard solutions. Henry's Law coefficients were calculated with a high degree of confidence. SIFT-MS analysis of five binary mixtures showed that the more polar compounds reduced the H/S concentration of the less polar compounds, while the addition of a less polar compound increased the H/S concentration of the more polar compound. In the binary experiment, it was shown that the behavior of a compound in the headspace can be significantly affected by the presence of another compound. Thus, the matrix effect plays a significant role in the behavior of molecules in a mixed solution. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Investigation of fragrance stability used in the formulation of cosmetic and hygienic products using headspace solid-phase microextraction by nanostructured materials followed by gas chromatography with mass spectrometry.

    PubMed

    Masoum, Saeed; Gholami, Ali; Ghaheri, Salehe; Bouveresse, Delphine Jouan-Rimbaud; Cordella, Christophe B Y; Rutledge, Douglas N

    2016-07-01

    A new composite coating of polypyrrole and sodium lauryl ether sulfate was electrochemically prepared on a stainless-steel wire using cyclic voltammetry. The application and performance of the fiber was evaluated for the headspace solid-phase microextraction of a fragrance in aqueous bleach samples followed by gas chromatography combined with mass spectrometry to assess the fragrance stability in this kind of household cleaning product. To obtain a stable and efficient composite coating, parameters related to the coating process such as scan rate and numbers of cycles were optimized using a central composite design. In addition, the effects of various parameters on the extraction efficiency of the headspace solid-phase microextraction process such as extraction temperature and time, ionic strength, sample volume, and stirring rate were investigated by experimental design methods using Plackett-Burman and Doehlert designs. The optimum values of 53°C and 28 min for sample temperature and time, respectively, were found through response surface methodology. Results show that the combination of polypyrrole and sodium lauryl ether sulfate in a composite form presents desirable opportunities to produce new materials to study fragrance stability by headspace solid-phase microextraction. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Coumarins as turn on/off fluorescent probes for detection of residual acetone in cosmetics following headspace single-drop microextraction.

    PubMed

    Cabaleiro, N; de la Calle, I; Bendicho, C; Lavilla, I

    2014-11-01

    In this work, a new method based on headspace-single drop microextraction for the determination of residual acetone in cosmetics by microfluorospectrometry is proposed. Acetone causes fluorescence changes in a 2.5 µL-ethanolic drop (40% v/v) containing 3.10(-4) mol L(-1) 7-hydroxy-4-methylcoumarin ('turn off') or 6.10(-6) mol L(-1) 7-diethylamino-4-methylcoumarin ('turn on'). Polarity and ability to form hydrogen bonds of short chain alcohols (polar protic solvents) were crucial in order to observe these changes in the presence of acetone (polar aprotic solvent). Parameters related with the HS-SDME procedure were studied, namely headspace volume, composition, volume and temperature of drop, microextraction time, stirring rate, mass and temperature of sample, as well as the effect of potential interferents (alcohols and fragrances). The high volatility of acetone allows its extraction from an untreated cosmetic sample within 3 min. A detection limit of 0.26 µg g(-1) and repeatability, expressed as relative standard deviation, around 5% were reached. Accuracy of the proposed methodology was evaluated by means of recovery studies. The method was successfully used to analyze different cosmetics. Simplicity and high sample throughput can be highlighted. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Headspace Solid-Phase Microextraction and Ultrasonic Extraction with the Solvent Sequences in Chemical Profiling of Allium ursinum L. Honey.

    PubMed

    Jerković, Igor; Kuś, Piotr M

    2017-11-06

    A volatile profile of ramson (wild garlic, Allium ursinum L.) honey was investigated by headspace solid-phase microextraction (HS-SPME) and ultrasonic solvent extraction (USE) followed by gas chromatography and mass spectrometry (GC-FID/GC-MS) analyses. The headspace was dominated by linalool derivatives: cis - and trans -linalool oxides (25.3%; 9.2%), hotrienol (12.7%), and linalool (5.8%). Besides direct extraction with dichloromethane and pentane/diethyl ether mixture (1:2, v / v ), two solvent sequences (I: pentane → diethyl ether; II: pentane → pentane/diethyl ether (1:2, v / v ) → dichloromethane) were applied. Striking differences were noted among the obtained chemical profiles. The extracts with diethyl ether contained hydroquinone (25.8-36.8%) and 4-hydroxybenzoic acid (11.6-16.6%) as the major compounds, while ( E )-4-(r-1',t-2',c-4'-trihydroxy-2',6',6'-trimethylcyclohexyl)but-3-en-2-one predominated in dichloromethane extracts (18.3-49.1%). Therefore, combination of different solvents was crucial for the comprehensive investigation of volatile organic compounds in this honey type. This particular magastigmane was previously reported only in thymus honey and hydroquinone in vipers bugloss honey, while a combination of the mentioned predominant compounds is unique for A. ursinum honey.

  10. Determination of organotin compounds by headspace solid-phase microextraction-gas chromatography-pulsed flame-photometric detection (HS-SPME-GC-PFPD).

    PubMed

    Bravo, Manuel; Lespes, Gaëtane; De Gregori, Ida; Pinochet, Hugo; Gautier, Martine Potin

    2005-12-01

    A method based on Headspace solid-phase microextraction (HS-SPME, with a 100 mum PDMS-fiber) in combination with gas-chromatography and pulsed flame-photometric detection (GC-PFPD) has been investigated for simultaneous determination of eight organotin compounds. Monobutyltin (MBT), dibutyltin (DBT), tributyltin (TBT), monophenyltin (MPhT), and the semi-volatile diphenyltin (DPhT), triphenyltin (TPhT), monooctyltin (MOcT), and dioctyltin (DOcT) were determined after derivatization with sodium tetraethylborate. The conditions used for the extraction and preconcentration step were optimised by experimental design methodology. Tripropyltin (TPrT) and diheptyltin (DHepT) were used as internal standards for quantification of volatile and semi-volatile organotin compounds, respectively. The analytical precision (RSD) for ten successive injections of a standard mixture containing all the organic tin compounds ranged between 2 and 11%. The limits of detection for all the organotin compounds were sub ng (Sn) L(-1) in water and close to ng (Sn) kg(-1) in sediments. The accuracy of the method was evaluated by analysis of two certified reference material (CRM) sediment samples. The HS-SPME-GC-PFPD was then applied to the analysis of three harbour sediment samples. The results showed that headspace SPME is an attractive tool for analysis of organotin compounds in solid environmental matrices.

  11. Results For The Fourth Quarter 2014 Tank 50 WAC Slurry Sample: Chemical And Radionuclide Contaminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, C.

    2015-09-30

    This report details the chemical and radionuclide contaminant results for the characterization of the Calendar Year (CY) 2014 Fourth Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by DWPF & Saltstone Facility Engineering (DSFE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System.

  12. Headspace concentrations of explosive vapors in containers designed for canine testing and training: theory, experiment, and canine trials.

    PubMed

    Lotspeich, Erica; Kitts, Kelley; Goodpaster, John

    2012-07-10

    It is a common misconception that the amount of explosive is the chief contributor to the quantity of vapor that is available to trained canines. In fact, this quantity (known as odor availability) depends not only on the amount of explosive material, but also the container volume, explosive vapor pressure and temperature. In order to better understand odor availability, headspace experiments were conducted and the results were compared to theory. The vapor-phase concentrations of three liquid explosives (nitromethane, nitroethane and nitropropane) were predicted using the Ideal Gas Law for containers of various volumes that are in use for canine testing. These predictions were verified through experiments that varied the amount of sample, the container size, and the temperature. These results demonstrated that the amount of sample that is needed to saturate different sized containers is small, predictable and agrees well with theory. In general, and as expected, once the headspace of a container is saturated, any subsequent increase in sample volume will not result in the release of more vapors. The ability of canines to recognize and alert to differing amounts of nitromethane has also been studied. In particular, it was found that the response of trained canines is independent of the amount of nitromethane present, provided it is a sufficient quantity to saturate the container in which it is held. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  13. Static headspace-gas chromatography-mass spectrometry for the simultaneous determination of trihalomethanes and haloacetic acids in canned vegetables.

    PubMed

    Cardador, Maria Jose; Gallego, Mercedes

    2016-07-08

    Canned vegetables appear to be a possible exposure pathway for hazardous disinfection by-products due to the use of sanitizers and treated water by the canning industry in the preparation of these foods. This work reports on two static headspace-gas chromatography-mass spectrometry methods for the simultaneous determination of 10 trihalomethanes (THMs) and 13 haloacetic acids (HAAs) in both solid and liquid phases of the canned vegetables. Both methods carry out the whole process (including the leaching of target analytes from the vegetable), derivatization of HAAs and volatilization of THMs and HAA esters, in a single step within a static headspace unit. The methods proposed provide an efficient and simple tool for the determination of regulated disinfection by-products in canned vegetables. Average limits of detection for THMs and HAAs were 0.19 and 0.45μg/kg, respectively, in the solid phase of canned vegetables, and 0.05 and 0.09μg/L, respectively, in the liquid phase. Satisfactory recoveries (90-99%) and precision, calculated as relative standard deviations (RSD≤10%), were obtained in both phases of canned vegetables. The methods proposed were applied for the analysis of frequently-used canned vegetables and confirmed the presence of up to 3 THMs and 5 HAAs at microgram per kilogram or liter levels in both phases of the samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Ionic liquids as advantageous solvents for headspace gas chromatography of compounds with low vapor pressure.

    PubMed

    Andre, M; Loidl, J; Laus, G; Schottenberger, H; Bentivoglio, G; Wurst, K; Ongania, K-H

    2005-01-15

    The potential of ionic liquids as solvents for headspace gas chromatography was investigated. Three compounds with boiling points above 200 degrees C were selected to demonstrate the feasibility of the concept described. 2-Ethylhexanoic acid, formamide, and tri-n-butylamine as examples of acidic, neutral, and basic analytes were dissolved in acidic 1-n-butyl-3-methylimidazolium hydrogen sulfate (1), neutral 1-n-butyl-2,3-dimethylimidazolium dicyanamide (2), and 2 containing 1,8-diazabicyclo[5.4.0]undec-7-ene to adjust basic conditions. All analytes could be determined with limits of detection and limits of quantification in the low-ppm concentration range.

  15. Headspace sorptive extraction-gas chromatography-mass spectrometry method to measure volatile emissions from human airway cell cultures.

    PubMed

    Yamaguchi, Mei S; McCartney, Mitchell M; Linderholm, Angela L; Ebeler, Susan E; Schivo, Michael; Davis, Cristina E

    2018-05-12

    The human respiratory tract releases volatile metabolites into exhaled breath that can be utilized for noninvasive health diagnostics. To understand the origin of this metabolic process, our group has previously analyzed the headspace above human epithelial cell cultures using solid phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS). In the present work, we improve our model by employing sorbent-covered magnetic stir bars for headspace sorptive extraction (HSSE). Sorbent-coated stir bar analyte recovery increased by 52 times and captured 97 more compounds than SPME. Our data show that HSSE is preferred over liquid extraction via stir bar sorptive extraction (SBSE), which failed to distinguish volatiles unique to the cell samples compared against media controls. Two different cellular media were also compared, and we found that Opti-MEM® is preferred for volatile analysis. We optimized HSSE analytical parameters such as extraction time (24 h), desorption temperature (300 °C) and desorption time (7 min). Finally, we developed an internal standard for cell culture VOC studies by introducing 842 ng of deuterated decane per 5 mL of cell medium to account for error from extraction, desorption, chromatography and detection. This improved model will serve as a platform for future metabolic cell culture studies to examine changes in epithelial VOCs caused by perturbations such as viral or bacterial infections, opening opportunities for improved, noninvasive pulmonary diagnostics. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Head-space, small-chamber and in-vehicle tests for volatile organic compounds (VOCs) emitted from air fresheners for the Korean market.

    PubMed

    Jo, Wan-Kuen; Lee, Jong-Hyo; Kim, Mo-Keun

    2008-02-01

    The present study investigated the emission characteristics of gel-type air fresheners (AFs), using head-space, small-chamber, and in-vehicle tests. Five toxic or hazardous analytes were found in the headspace phase of AFs (toluene, benzene, ethyl benzene, and m,p-xylene) at a frequency of more than 50%. Limonene and linalool, which are known to be unsaturated ozone-reactive VOCs, were detected at a frequency of 58 and 35%, respectively. The empirical model fitted well with the time-series concentrations in the chamber, thereby suggesting that the empirical model was suitable for testing emissions. Limonene exhibited the highest emission rate, followed by m,p-xylene, toluene, ethyl benzene, and benzene. For most target VOCs, higher air change per hour (ACH) levels exhibited increased emission rates. In contrast, higher ACH levels resulted in lower chamber concentrations. The mean concentration of limonene was significantly higher in passenger cars with an AF than without. For other target compounds, there were no significant differences between the two conditions tested. Consequently, it was suggested that unlike limonene, the emission strength for aromatic compounds identified in the chamber tests was not strong enough to elevate in-vehicle levels.

  17. Ionic liquid supported on an electrodeposited polycarbazole film for the headspace solid-phase microextraction and gas chromatography determination of aromatic esters.

    PubMed

    Feng, Yuanyuan; Zhao, Faqiong; Zeng, Baizhao

    2015-05-01

    A polycarbazole film was electrodeposited on a stainless-steel wire from a solution of N,N-dimethylformamide/propylene carbonate (1:9 v/v) containing 0.10 M carbazole and 0.10 M tetrabutylammonium perchlorate. The obtained polycarbazole fiber was immersed into an ionic liquid (1-hydroxyethyl-3-methyl imidazolium bis[(trifluoromethyl)sulfonyl]imide) solution (in dimethylsulfoxide) for 30 min, followed by drying under an infrared lamp. The resulting polycarbazole/ionic liquid fiber was applied to the headspace solid-phase microextraction and determination of aromatic esters by coupling with gas chromatography and flame ionization detection. Under the optimized conditions, the limits of detection were below 61 ng/L (S/N = 3) and the linear ranges were 0.061-500 μg/L with correlation coefficients above 0.9876. The relative standard deviations were below 4.8% (n = 5) for a single fiber, and below 9.9% for multi-fiber (n = 4). This fiber also exhibited good stability. It could be used for more than 160 times of headspace solid-phase microextraction and could withstand a high temperature up to 350°C. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Determination of 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce by headspace derivatization solid-phase microextraction combined with gas chromatography-mass spectrometry.

    PubMed

    Lee, Maw-Rong; Chiu, Tzu-Chun; Dou, Jianpeng

    2007-05-22

    This study proposes a method for identifying 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous matrices by using headspace on-fiber derivatization following solid-phase microextraction combined with gas chromatography-mass spectrometry. The optimized SPME experimental procedures for extracting 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in aqueous solutions involved a 85 microm polyacrylate-coated fiber at pH 6, a sodium chloride concentration of 0.36 g mL(-1), extraction at 50 degrees C for 15 min and desorption of analytes at 260 degrees C for 3 min. Headspace derivatization was conducted in a laboratory-made design with N-methyl-N-(trimethylsilyl)-trifluoroacetamide vapor following solid-phase microextraction by using 3 microL N-methyl-N-(trimethylsilyl)-trifluoroacetamide at an oil bath temperature of 230 degrees C for 40 s. This method had good repeatability (R.S.D.s < or = 19%, n = 8) and good linearity (r2 > or = 0.9972) for ultrapure water and soy sauce samples that were spiked with two analytes. Detection limits were obtained at the ng mL(-1). The result demonstrated that headspace on-fiber derivatization following solid-phase microextraction was a simple, fast and accurate technique for identifying trace 1,3-dichloro-2-propanol and 3-chloro-1,2-propandiol in soy sauce.

  19. The effect of surfactant on headspace single drop microextraction for the determination of some volatile aroma compounds in citronella grass and lemongrass leaves by gas chromatography

    USDA-ARS?s Scientific Manuscript database

    A rapid method for the determination of some volatile aromatic compounds (VACs), including citronellal, citronellol, neral, geranial, geraniol, and eugenol in citronella grass and lemongrass leaves, was developed using surfactant as a surface tension modifier while performing headspace single drop m...

  20. EVALUATION OF FABRIC MEMBRANES FOR USE IN SALTSTONE DRAIN WATER SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickenheim, B.; Miller, D.; Burket, P.

    2012-03-08

    Saltstone Disposal Unit 2 contains a sheet drain fabric intended to separate solids from drain water to be returned to the Salt Feed Tank. A similar system installed in Vault 4 appears to be ineffective in keeping solids out of the drain water return lines. Waste Solidification Engineering is considering installation of an additional fabric membrane to supplement the existing sheet drain in SDU 2. Amerdrain 200 is the product currently installed in SDU 2. This product is no longer available, so Sitedrain 94 was used as the replacement product in this testing. Fabrics with apparent opening sizes of 10,more » 25, 50 and 100 microns were evaluated. These fabrics were evaluated under three separate test conditions, a water flow test, a solids retention test and a grout pour test. A flow test with water showed that installation of an additional filter layer will predictably reduce the theoretical flux through the sheet drain. The manufacturer reports the flux for Sitedrain 94 as 150 gpm/ft{sup 2} by ASTM D-4491. This compares reasonably well with the 117 gpm/ft{sup 2} obtained in this testing. A combination of the 10 micron fabric with Sitedrain 94 could be expected to decrease flux by about 10 times as compared to Sitedrain 94 alone. The different media were used to filter a slag and fly ash mixture from water. Slag historically has the smallest nominal particle size of the premix components. Cement was omitted from the test because of its reactivity with water would prohibit accurately particle size measurements of the filtered samples. All four media sizes were able to remove greater than 95% of particles larger than 100 microns from the slurry. The smaller opening sizes were increasingly effective in removing more particles. The 10 micron filter captured 15% of the total amount of solids used in the test. This result implies that some insoluble particles may still be able to enter the drain water collection system, although the overall solids rejection is

  1. Rapid determination of moisture content in paper materials by multiple headspace extraction gas chromatography.

    PubMed

    Xie, Wei-Qi; Chai, Xin-Sheng

    2016-04-22

    This paper describes a new method for the rapid determination of the moisture content in paper materials. The method is based on multiple headspace extraction gas chromatography (MHE-GC) at a temperature above the boiling point of water, from which an integrated water loss from the tested sample due to evaporation can be measured and from which the moisture content in the sample can be determined. The results show that the new method has a good precision (with the relative standard deviation <0.96%), high sensitivity (the limit of quantitation=0.005%) and good accuracy (the relative differences <1.4%). Therefore, the method is quite suitable for many uses in research and industrial applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Rapid quantitative detection of glucose content in glucose injection by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-10-20

    This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences <6.45%). The new HS-GC technique is rapid, practical and can be used to the batch detection of the glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Improvement of a headspace solid phase microextraction-gas chromatography/mass spectrometry method for the analysis of wheat bread volatile compounds.

    PubMed

    Raffo, Antonio; Carcea, Marina; Castagna, Claudia; Magrì, Andrea

    2015-08-07

    An improved method based on headspace solid phase microextraction combined with gas chromatography-mass spectrometry (HS-SPME/GC-MS) was proposed for the semi-quantitative determination of wheat bread volatile compounds isolated from both whole slice and crust samples. A DVB/CAR/PDMS fibre was used to extract volatiles from the headspace of a bread powdered sample dispersed in a sodium chloride (20%) aqueous solution and kept for 60min at 50°C under controlled stirring. Thirty-nine out of all the extracted volatiles were fully identified, whereas for 95 other volatiles a tentative identification was proposed, to give a complete as possible profile of wheat bread volatile compounds. The use of an array of ten structurally and physicochemically similar internal standards allowed to markedly improve method precision with respect to previous HS-SPME/GC-MS methods for bread volatiles. Good linearity of the method was verified for a selection of volatiles from several chemical groups by calibration with matrix-matched extraction solutions. This simple, rapid, precise and sensitive method could represent a valuable tool to obtain semi-quantitative information when investigating the influence of technological factors on volatiles formation in wheat bread and other bakery products. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Degradation product emission from historic and modern books by headspace SPME/GC-MS: evaluation of lipid oxidation and cellulose hydrolysis.

    PubMed

    Clark, Andrew J; Calvillo, Jesse L; Roosa, Mark S; Green, David B; Ganske, Jane A

    2011-04-01

    Volatile organic compounds emitted from a several decade series of bound periodicals (1859-1939) printed on ground wood paper, as well as historical books dating from the 1500s to early 1800s made from cotton/linen rag, were studied using an improved headspace SPME/GC-MS method. The headspace over the naturally aging books, stored upright in glass chambers, was monitored over a 24-h period, enabling the identification of a wide range of organic compounds emanating from the whole of the book. The detection of particular straight chain aldehydes, as well as characteristic alcohols, alkenes and ketones is correlated with oxidative degradation of the C(18) fatty acid constituency of paper. The relative importance of hydrolytic and oxidative chemistry involved in paper aging in books published between 1560 and 1939 was examined by comparing the relative abundances of furfural (FUR) a known cellulose hydrolysis product, and straight chain aldehydes (SCA) produced from the oxidation of fatty acids in paper. The relative abundance of furfural is shown to increase across the 379-year publication time span. A comparison of relative SCA peak areas across the series of books examined reveals that SCA emission is more important in the cotton/linen rag books than in the ground wood books.

  5. Development of a dynamic headspace gas chromatography-mass spectrometry method for on-site analysis of sulfur mustard degradation products in sediments.

    PubMed

    Magnusson, R; Nordlander, T; Östin, A

    2016-01-15

    Sampling teams performing work at sea in areas where chemical munitions may have been dumped require rapid and reliable analytical methods for verifying sulfur mustard leakage from suspected objects. Here we present such an on-site analysis method based on dynamic headspace GC-MS for analysis of five cyclic sulfur mustard degradation products that have previously been detected in sediments from chemical weapon dumping sites: 1,4-oxathiane, 1,3-dithiolane, 1,4-dithiane, 1,4,5-oxadithiephane, and 1,2,5-trithiephane. An experimental design involving authentic Baltic Sea sediments spiked with the target analytes was used to develop an optimized protocol for sample preparation, headspace extraction and analysis that afforded recoveries of up to 60-90%. The optimized method needs no organic solvents, uses only two grams of sediment on a dry weight basis and involves a unique sample presentation whereby sediment is spread uniformly as a thin layer inside the walls of a glass headspace vial. The method showed good linearity for analyte concentrations of 5-200 ng/g dw, good repeatability, and acceptable carry-over. The method's limits of detection for spiked sediment samples ranged from 2.5 to 11 μg/kg dw, with matrix interference being the main limiting factor. The instrumental detection limits were one to two orders of magnitude lower. Full-scan GC-MS analysis enabled the use of automated mass spectral deconvolution for rapid identification of target analytes. Using this approach, analytes could be identified in spiked sediment samples at concentrations down to 13-65 μg/kg dw. On-site validation experiments conducted aboard the research vessel R/V Oceania demonstrated the method's practical applicability, enabling the successful identification of four cyclic sulfur mustard degradation products at concentrations of 15-308μg/kg in sediments immediately after being collected near a wreck at the Bornholm Deep dumpsite in the Baltic Sea. Copyright © 2015 Elsevier B.V. All

  6. Results for the Fourth Quarter Calendar Year 2015 Tank 50H Salt Solution Sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, C.

    In this memorandum, the chemical and radionuclide contaminant results from the Fourth Quarter Calendar Year 2015 (CY15) sample of Tank 50H salt solution are presented in tabulated form. The Fourth Quarter CY15 Tank 50H samples were obtained on October 29, 2015 and received at Savannah River National Laboratory (SRNL) on October 30, 2015. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Production Facility, where the waste will be treated and disposed of inmore » the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Fourth Quarter Calendar Year 2015 (CY15) sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan.« less

  7. Analysis of volatile secondary metabolites from Colombian Xylopia aromatica (Lamarck) by different extraction and headspace methods and gas chromatography.

    PubMed

    Stashenko, Elena E; Jaramillo, Beatriz E; Martínez, Jairo René

    2004-01-30

    Hydrodistillation (HD), simultaneous distillation-solvent extraction (SDE), microwave-assisted hydrodistillation (MWHD), and supercritical fluid (CO2) extraction (SFE), were employed to isolate volatile secondary metabolites from Colombian Xylopia aromatica (Lamarck) fruits. Static headspace (S-HS), simultaneous purge and trap (P&T) in solvent (CH2Cl2), and headspace (HS) solid-phase microextraction (SPME) were utilised to obtain volatile fractions from fruits of X. aromatica trees, which grow wild in Central and South America, and are abundant in Colombia. Kováts indices, mass spectra or standard compounds, were used to identify more than 50 individual components in the various volatile fractions. beta-Phellandrene was the main component found in the HD and MWHD essential oils, SDE and SFE extracts (61, 65, 57, and ca. 40%, respectively), followed by beta-myrcene (9.1, 9.3, 8.2 and 5.1%), and alpha-pinene (8.1, 7.3, 8.1 and 5.9%). The main components present in the volatile fractions of the X. aromatica fruits, isolated by S-HS, P&T and HS-SPME were beta-phellandrene (53.8, 35.7 and 39%), beta-myrcene (13.3, 12.3 and 10.1%), p-mentha-1(7),8-diene (7.1, 10.6 and 10.4%), alpha-phellandrene (2.2, 5.0 and 6.4%), and p-cymene (2.2,4.7 and 4.4%), respectively.

  8. Determination of cannabinoids in hemp food products by use of headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Lachenmeier, Dirk W; Kroener, Lars; Musshoff, Frank; Madea, Burkhard

    2004-01-01

    A fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME), followed by on-fiber derivatization and gas chromatographic-mass spectrometric (GC-MS) detection has been developed for determination of cannabinoids in hemp food samples. After addition of a deuterated internal standard, the sample was hydrolyzed with sodium hydroxide and submitted to direct HS-SPME. After absorption of analytes for on-fiber derivatization, the fiber was placed directly into the headspace of a second vial containing N-methyl- N-trimethylsilyltrifluoroacetamide (MSTFA), before GC-MS analysis. Linearity was good for Delta(9)-tetrahydrocannabinol (THC), cannabidiol, and cannabinol; regression coefficients were greater than 0.99. Depending on the characteristics of the matrix the detection limits obtained ranged between 0.01 and 0.17 mg kg(-1) and the precision between 0.4 and 11.8%. In comparison with conventional liquid-liquid extraction this automated HS-SPME-GC-MS procedure is substantially faster. It is easy to perform, solvent-free, and sample quantities are minimal, yet it maintains the same sensitivity and reproducibility. The applicability was demonstrated by analysis of 30 hemp food samples. Cannabinoids were detected in all of the samples and it was possible to differentiate between drug-type and fiber-type Cannabis sativa L. In comparison with other studies relatively low THC concentrations between 0.01 and 15.53 mg kg(-1) were determined.

  9. Tank vapor characterization project. Headspace vapor characterization of Hanford waste tank 241-BY-108: Second comparison study results from samples collected on 3/28/96

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, B.L.; Pool, K.H.; Evans, J.C.

    1997-01-01

    This report describes the analytical results of vapor samples taken from the headspace of waste storage tank 241-BY-108 (Tank BY-108) at the Hanford Site in Washington State. The results described in this report is the second in a series comparing vapor sampling of the tank headspace using the Vapor Sampling System (VSS) and In Situ Vapor Sampling (ISVS) system without high efficiency particulate air (HEPA) prefiltration. The results include air concentrations of water (H{sub 2}O) and ammonia (NH{sub 3}), permanent gases, total non-methane organic compounds (TO-12), and individual organic analytes collected in SUMMA{trademark} canisters and on triple sorbent traps (TSTs).more » Samples were collected by Westinghouse Hanford Company (WHC) and analyzed by Pacific Northwest National Laboratory (PNNL). Analyses were performed by the Vapor Analytical Laboratory (VAL) at PNNL. Analyte concentrations were based on analytical results and, where appropriate, sample volume measurements provided by WHC.« less

  10. Headspace solid-phase microextraction for the determination of volatile and semi-volatile pollutants in water and air.

    PubMed

    Llompart, M; Li, K; Fingas, M

    1998-10-16

    In this work we report the use of solid-phase microextraction (SPME) to extract and concentrate water-soluble volatile as well as semi-volatile pollutants. Both methods of exposing the SPME fibre were utilised: immersion in the aqueous solution (SPME) and in the headspace over the solution (HSSPME). The proposed HSSPME procedure was compared to conventional static headspace (HS) analysis for artificially spiked water as well as real water samples, which had been, equilibrated with various oil and petroleum products. Both techniques gave similar results but HSSPME was much more sensitive and exhibited better precision. Detection limits were found to be in the sub-ng/ml level, with precision better than 5% R.S.D. in most cases. To evaluate the suitability of SPME for relatively high contamination level analysis, the proposed HSSPME method was applied to the screening of run-off water samples that had heavy oil suspended in them from a tire fire incident. HSSPME results were compared with liquid--liquid extraction. Library searches were conducted on the resulting GC-MS total ion chromatograms to determine the types of compounds found in such samples. Both techniques found similar composition in the water samples with the exception of alkylnaphthalenes that were detected only by HSSPME. A brief study was carried out to assess using SPME for air monitoring. By sampling and concentrating the volatile organic compounds in the coating of the SPME fibre without any other equipment, this new technique is useful as an alternative to active air monitoring by means of sampling pumps and sorbent tubes.

  11. Hydrogen cyanide in the headspace of oral fluid and in mouth-exhaled breath.

    PubMed

    Chen, W; Metsälä, M; Vaittinen, O; Halonen, L

    2014-06-01

    Mouth-exhaled hydrogen cyanide (HCN) concentrations have previously been reported to originate from the oral cavity. However, a direct correlation between the HCN concentration in oral fluid and in mouth-exhaled breath has not been explicitly shown. In this study, we set up a new methodology to simultaneously measure HCN in the headspace of oral fluid and in mouth-exhaled breath. Our results show that there is a statistically significant correlation between stimulated oral fluid HCN and mouth-exhaled HCN (rs = 0.76, p < 0.001). This confirms that oral fluid is the main contributor to mouth-exhaled HCN. Furthermore, we observe that after the application of an oral disinfectant, both the stimulated oral fluid and mouth-exhaled HCN concentrations decrease. This implies that HCN production in the oral cavity is related to the bacterial and/or enzymatic activity.

  12. Analysis of acrylonitrile, 1,3-butadiene, and related compounds in acrylonitrile-butadiene-styrene copolymers for kitchen utensils and children's toys by headspace gas chromatography/mass spectrometry.

    PubMed

    Ohno, Hiroyuki; Kawamura, Yoko

    2010-01-01

    A headspace gas chromatography/mass spectrometry method was developed for the simultaneous determination of the residual levels of acrylonitrile (AN), 1,3-butadiene (1,3-BD), and their related compounds containing propionitrile (PN) and 4-vinyl-1-cyclohexene (4-VC) in acrylonitrile-butadiene-styrene (ABS) copolymers for kitchen utensils and children's toys. A sample was cut into small pieces, then N,N-dimethylacetamide and an internal standard were added in a sealed headspace vial. The vial was incubated for 1 h at 90 degrees C and the headspace gas was analyzed by gas chromatography/mass spectrometry. The recovery rates of the analytes were 93.3-101.8% and the coefficients of variation were 0.3-6.5%. In ABS copolymers, the levels were 0.3-50.4 microg/g for AN, ND-4.5 microg/g for PN, 0.06-1.58 microg/g for 1,3-BD, and 1.1-295 microg/g for 4-VC. The highest level was found for 4-VC, which is a dimer of 1,3-BD, and the next highest was for AN, which is one of the monomers of the ABS copolymer. Furthermore, the method was also applied to acrylonitrile-styrene (AS) copolymers and polystyrenes (PS) for kitchen utensils, and nitrile-butadiene rubber (NBR) gloves. In AS copolymers, AN and PN were detected at 16.8-54.5 and 0.8-6.9 microg/g, respectively. On the other hand, the levels in PS and NBR samples were all low.

  13. Headspace solid-phase microextraction coupled to comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for the analysis of aerosol from tobacco heating product.

    PubMed

    Savareear, Benjamin; Lizak, Radoslaw; Brokl, Michał; Wright, Chris; Liu, Chuan; Focant, Jean-Francois

    2017-10-20

    A method involving headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was developed and optimised to elucidate the volatile composition of the particulate phase fraction of aerosol produced by tobacco heating products (THPs). Three SPME fiber types were studied in terms of extraction capacity and precision measurements. Divinylbenzene polydimethylsiloxane appeared as the most efficient coating for these measurements. A central composite design of experiment was utilised for the optimization of the extraction conditions. Qualitative and semi-quantitative analysis of the headspace above THP aerosol condensate was carried out using optimised extraction conditions. Semi-quantitative analyses of detected constituents were performed by assuming that their relative response factors to the closest internal standard ( i t R ) were equal to 1. Using deconvoluted mass spectral data (library similarity and reverse match >750) and linear retention indices (match window of ±15 index units), 205 peaks were assigned to individual compounds, 82 of which (including 43 substances previously reported to be present in tobacco) have not been reported previously in tobacco aerosol. The major volatile fraction of the headspace contained ketones, alcohols, aldehydes, alicyclic hydrocarbons alkenes, and alkanes. The method was further applied to compare the volatiles from the particulate phase of aerosol composition of THP with that of reference cigarette smoke and showed that the THP produced a less complex chemical mixture. This new method showed good efficiency and precision for the peak areas and peak numbers from the volatile fraction of aerosol particulate phase for both THP and reference cigarettes. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Headspace and direct immersion solid phase microextraction procedures for selenite determination in urine, saliva and milk by gas chromatography mass spectrometry.

    PubMed

    Kapsimali, D C; Zachariadis, G A

    2009-10-01

    Two solid phase microextraction modes were investigated and compared for their performance on the determination of selenites in various biological liquids like human urine and saliva and various types of milk. Using sodium tetraethylborate (NaBEt(4)) as ethylating reagent, selenites are converted in situ to volatile diethylselenides (DESe) in aqueous medium. The derivative is collected in situ by solid phase microextraction (SPME) using a silica fiber coated with poly(dimethylsiloxane) (PDMS) either from the headspace (HS-SPME) or directly from the liquid phase (LP-SPME) and finally determined by capillary GC/MS. Under optimum conditions of SPME, the GC separation was also optimized. Between the two examined microextraction techniques, direct immersion of the PDMS fiber in the liquid phase was proved less satisfactory. In contrast, the headspace procedure appears to be more efficient. The quantification of selenites was achieved in SIM mode with good analytical performance. A non-fat milk powder certified reference material was analyzed to evaluate the accuracy of the method. The overall precision of the method was ranged between 6.2% and 9.7%. Detection limits achieved were 0.05microgL(-1) for human urine, 0.08microgL(-1) for saliva and 0.03-0.06microgL(-1) in various milk matrices.

  15. Measurement of isoprene solubility in water, human blood and plasma by multiple headspace extraction gas chromatography coupled with solid phase microextraction.

    PubMed

    Mochalski, Paweł; King, Julian; Kupferthaler, Alexander; Unterkofler, Karl; Hinterhuber, Hartmann; Amann, Anton

    2011-12-01

    The aim of this study was to determine the solubility (liquid-to-air ratios) of isoprene in water, human blood and plasma. To this end, an experimental setup combining multiple headspace extraction, solid phase microextraction and gas chromatography-mass spectrometry was applied. The water:air partition coefficients of isoprene were determined for the temperature range 4.5-37 °C and amounted to 1.171-0.277 (g mL(l)(-1)) (g mL(a)(-1))(-1). On the basis of these data, the enthalpy of volatilization was calculated as 29.46 ± 2.83 kJ mol(-1). The blood:air partition coefficients at 37 °C were determined for ten normal healthy volunteers spread around a median value of 0.95 ± 0.09 (g mL(l)(-1)) (g mL(a)(-1))(-1) and were approximately 16% lower than the plasma:air partition coefficients (1.11 ± 0.2). The applied methodology can be particularly attractive for solubility studies targeting species at very low concentrations in the solution, i.e. when headspace sample enrichment is necessary to provide sufficient measurement sensitivity and reliability. This can be especially helpful if environmental or physiological solute levels have to be considered.

  16. Effectiveness of Liquid-Liquid Extraction, Solid Phase Extraction, and Headspace Technique for Determination of Some Volatile Water-Soluble Compounds of Rose Aromatic Water

    PubMed Central

    2017-01-01

    Steam distillation is used to isolate scent of rose flowers. Rose aromatic water is commonly used in European cuisine and aromatherapy besides its use in cosmetic industry for its lovely scent. In this study, three different sampling techniques, liquid-liquid extraction (LLE), headspace technique (HS), and solid phase extraction (SPE), were compared for the analysis of volatile water-soluble compounds in commercial rose aromatic water. Some volatile water-soluble compounds of rose aromatic water were also analyzed by gas chromatography mass spectrometry (GCMS). In any case, it was concluded that one of the solid phase extraction methods led to higher recoveries for 2-phenylethyl alcohol (PEA) in the rose aromatic water than the liquid-liquid extraction and headspace technique. Liquid-liquid extraction method provided higher recovery ratios for citronellol, nerol, and geraniol than others. Ideal linear correlation coefficient values were observed by GCMS for quantitative analysis of volatile compounds (r2 ≥ 0.999). Optimized methods showed acceptable repeatability (RSDs < 5%) and excellent recovery (>95%). For compounds such as α-pinene, linalool, β-caryophyllene, α-humulene, methyl eugenol, and eugenol, the best recovery values were obtained with LLE and SPE. PMID:28791049

  17. A paper-based analytical device for the determination of hydrogen sulfide in fuel oils based on headspace liquid-phase microextraction and cyclic voltammetry.

    PubMed

    Nechaeva, Daria; Shishov, Andrey; Ermakov, Sergey; Bulatov, Andrey

    2018-06-01

    An easily performed miniaturized, cheap, selective and sensitive procedure for the determination of H 2 S in fuel oil samples based on a headspace liquid-phase microextraction followed by a cyclic voltammetry detection using a paper-based analytical device (PAD) was developed. A modified wax dipping method was applied to fabricate the PAD. The PAD included hydrophobic zones of sample and supporting electrolyte connecting by hydrophilic channel. The zones of sample and supporting electrolyte were connected with nickel working, platinum auxiliary and Ag/AgCl reference electrodes. The analytical procedure included separation of H 2 S from fuel oil sample based on the headspace liquid-phase microextraction in alkaline solution. Then, sulfide ions solution obtained and supporting electrolyte were dropped on the zones followed by analyte detection at + 0.45 V. Under the optimized conditions, H 2 S concentration in the range from 2 to 20 mg kg -1 had a good linear relation with the peak current. The limit of detection (3σ) was 0.6 mg kg -1 . The procedure was successfully applied to the analysis of fuel oil samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Development of a headspace GC/MS analysis for carbonyl compounds (aldehydes and ketones) in household products after derivatization with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine.

    PubMed

    Sugaya, Naeko; Sakurai, Katsumi; Nakagawa, Tomoo; Onda, Nobuhiko; Onodera, Sukeo; Morita, Masatoshi; Tezuka, Masakatsu

    2004-05-01

    Carbonyl compounds (aldehydes and ketones) are suspected to be among the chemical compounds responsible for Sick Building Syndrome and Multiple Chemical Sensitivities. A headspace gas chromatography/mass spectrometry (GC/MS) analysis for these compounds was developed using derivatization of the compounds into volatile derivatives with o-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBOA). For GC/MS detection, two ionization modes including electron impact ionization (EI) and negative chemical ionization (NCI) were compared. The NCI mode seemed to be better because of its higher selectivity and sensitivity. This headspace GC/MS (NCI mode) was employed as analysis for aldehydes and ketones in materials (fiber products, adhesives, and printed materials). Formaldehyde was detected in the range of N.D. (not detected) to 39 microg/g; acetaldehyde, N.D. to 4.1 microg/g; propionaldehyde, N.D. to 1.0 microg/g; n-butyraldehyde, N.D. to 0.10 microg/g; and acetone, N.D. to 3.1 microg/g in the samples analyzed.

  19. Determination of volatile organic acids in oriental tobacco by needle-based derivatization headspace liquid-phase microextraction coupled to gas chromatography/mass spectrometry.

    PubMed

    Sun, Shi-Hao; Xie, Jian-Ping; Xie, Fu-Wei; Zong, Yong-Li

    2008-02-01

    A method coupling needle-based derivatization headspace liquid-phase microextraction with gas chromatography-mass spectrometry (HS-LPME/GC-MS) was developed to determine volatile organic acids in tobacco. The mixture of N,O-bis(trimethylsilyl)trifluoroacetamide and decane was utilized as the solvent for HS-LPME, resulting that extraction and derivatization were simultaneously completed in one step. The solvent served two purposes. First, it pre-concentrated volatile organic acids in the headspace of tobacco sample. Second, the volatile organic acids extracted were derivatized to form silyl derivatives in the drop. The main parameters affecting needle-based derivatization HS-LPME procedure such as extraction and derivatization reagent, microdrop volume, extraction and derivatization time, and preheating temperature and preheating time were optimized. The standard addition approach was essential to obtain accurate measurements by minimizing matrix effects. Good linearity (R(2)> or =0.9804) and good repeatability (RSDs< or =15.3%, n=5) for 16 analytes in spiked standard analytes sample were achieved. The method has the additional advantages that at the same time it is simple, fast, effective, sensitive, selective, and provides an overall profile of volatile organic acids in the oriental tobacco. This paper does offer an alternative approach to determine volatile organic acids in tobacco.

  20. Headspace single drop microextraction versus dispersive liquid-liquid microextraction using magnetic ionic liquid extraction solvents.

    PubMed

    An, Jiwoo; Rahn, Kira L; Anderson, Jared L

    2017-05-15

    A headspace single drop microextraction (HS-SDME) method and a dispersive liquid-liquid microextraction (DLLME) method were developed using two tetrachloromanganate ([MnCl 4 2- ])-based magnetic ionic liquids (MIL) as extraction solvents for the determination of twelve aromatic compounds, including four polyaromatic hydrocarbons, by reversed phase high-performance liquid chromatography (HPLC). The analytical performance of the developed HS-SDME method was compared to the DLLME approach employing the same MILs. In the HS-SDME approach, the magnetic field generated by the magnet was exploited to suspend the MIL solvent from the tip of a rod magnet. The utilization of MILs in HS-SDME resulted in a highly stable microdroplet under elevated temperatures and long extraction times, overcoming a common challenge encountered in traditional SDME approaches of droplet instability. The low UV absorbance of the [MnCl 4 2- ]-based MILs permitted direct analysis of the analyte enriched extraction solvent by HPLC. In HS-SDME, the effects of ionic strength of the sample solution, temperature of the extraction system, extraction time, stir rate, and headspace volume on extraction efficiencies were examined. Coefficients of determination (R 2 ) ranged from 0.994 to 0.999 and limits of detection (LODs) varied from 0.04 to 1.0μgL -1 with relative recoveries from lake water ranging from 70.2% to 109.6%. For the DLLME method, parameters including disperser solvent type and volume, ionic strength of the sample solution, mass of extraction solvent, and extraction time were studied and optimized. Coefficients of determination for the DLLME method varied from 0.997 to 0.999 with LODs ranging from 0.05 to 1.0μgL -1 . Relative recoveries from lake water samples ranged from 68.7% to 104.5%. Overall, the DLLME approach permitted faster extraction times and higher enrichment factors for analytes with low vapor pressure whereas the HS-SDME approach exhibited better extraction efficiencies for

  1. Multiple headspace-solid-phase microextraction: an application to quantification of mushroom volatiles.

    PubMed

    Costa, Rosaria; Tedone, Laura; De Grazia, Selenia; Dugo, Paola; Mondello, Luigi

    2013-04-03

    Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC-MS) and flame ionization detection (GC-FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033-0.078 ng), limit of quantification (LoQ, range 0.111-0.259 ng) and analyte recovery (92.3-108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Analysis of volatile organic compounds in pleural effusions by headspace solid-phase microextraction coupled with cryotrap gas chromatography and mass spectrometry.

    PubMed

    Huang, Zhongping; Zhang, Jie; Zhang, Peipei; Wang, Hong; Pan, Zaifa; Wang, Lili

    2016-07-01

    Headspace solid-phase microextraction coupled with cryotrap gas chromatography and mass spectrometry was applied to the analysis of volatile organic compounds in pleural effusions. The highly volatile organic compounds were separated successfully with high sensitivity by the employment of a cryotrap device, with the construction of a cold column head by freezing a segment of metal capillary with liquid nitrogen. A total of 76 volatile organic compounds were identified in 50 pleural effusion samples (20 malignant effusions and 30 benign effusions). Among them, 34 more volatile organic compounds were detected with the retention time less than 8 min, by comparing with the normal headspace solid-phase microextraction coupled with gas chromatography and mass spectrometry method. Furthermore, 24 volatile organic compounds with high occurrence frequency in pleural effusion samples, 18 of which with the retention time less than 8 min, were selected for the comparative analysis. The results of average peak area comparison and box-plot analysis showed that except for cyclohexanone, 2-ethyl-1-hexanol, and tetramethylbenzene, which have been reported as potential cancer biomarkers, cyclohexanol, dichloromethane, ethyl acetate, n-heptane, ethylbenzene, and xylene also had differential expression between malignant and benign effusions. Therefore, the proposed approach was valuable for the comprehensive characterization of volatile organic compounds in pleural effusions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Headspace needle-trap analysis of priority volatile organic compounds from aqueous samples: application to the analysis of natural and waste waters.

    PubMed

    Alonso, Monica; Cerdan, Laura; Godayol, Anna; Anticó, Enriqueta; Sanchez, Juan M

    2011-11-11

    Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L⁻¹ range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Headspace oxygen as a hurdle to improve the safety of in-pack pasteurized chilled food during storage at different temperatures.

    PubMed

    Muñoz, Nydia; Bhunia, Kanishka; Zhang, Hongchao; Barbosa-Cánovas, Gustavo V; Tang, Juming; Sablani, Shyam

    2017-07-17

    This study investigated the use of headspace oxygen in a model food system to prevent the growth of anaerobic pathogenic bacteria in in-pack pasteurized food at various storage temperatures. Three model food formulations prepared with tryptic soy broth and three agar concentrations (0.1, 0.4 and 1.0%) were sealed without removing the air from the package in high oxygen barrier pouches (OTR=0.3cm 3 /m 2 ·day·atm). Important properties influencing bacterial growth, including pH and water activity (a w ) were determined. The oxygen sorption kinetics of each model food were obtained at three different storage temperatures (8, 12, and 20°C) using an OxySense Gen III 300 system. An analytical solution of Fick's second law was used to determine the O 2 diffusion coefficient. Growth challenge studies at 12 and 20°C were conducted at three selected locations (top, center and bottom layers) in model foods containing 1% agar. Model foods were inoculated with Clostridium sporogenes PA 3679 (300spores/mL), and were classified as low-acid (pH>4.5, a w >0.85). When the storage temperature decreased from 20 to 8°C, the oxygen diffusion decreased from 0.82×10 -9 m 2 /s to 0.68×10 -9 m 2 /s. As the agar concentration was increased from 0.1 to 1.0%, the effective oxygen permeability decreased significantly (p=0.007) from 0.88×10 -9 m 2 /s to 0.65×10 -9 m 2 /s. When the inoculated model foods were stored at 12°C for 14days, C. sporogenes PA 3679 was unable to grow. As the storage temperature was increased to 20°C, significant bacterial growth was observed with storage time (p<0.0001), and the C. sporogenes PA 3679 population increased by around 6logCFU/g. However, the location of the food did not influence the growth distribution of C. sporogenes PA 3679. These results demonstrate that oxygen diffusion from the pouch headspace was primarily limited to the food surface. Findings suggest that the air/oxygen present in the package headspace may not be considered as a food

  5. Determination of (2)H-enrichment of rat brain interstitial fluid and rat plasma by headspace-gas-chromatography - quadrupole-mass-spectrometry.

    PubMed

    Eberl, Anita; Altendorfer-Kroath, Thomas; Kollmann, Denise; Birngruber, Thomas; Sinner, Frank; Raml, Reingard; Magnes, Christoph

    2016-09-15

    (2)H2O as nonradioactive, stable marker substance is commonly used in preclinical and clinical studies and the precise determination of (2)H2O concentration in biological samples is crucial. However, aside from isotope ratio mass spectrometry (IRMS), only a very limited number of methods to accurately measure the (2)H2O concentration in biological samples are routinely established until now. In this study, we present a straightforward method to accurately measure (2)H-enrichment of rat brain interstitial fluid (ISF) and rat plasma to determine the relative recovery of a cerebral open flow microperfusion (cOFM) probe, using headspace-gas-chromatography - quadrupole-mass-spectrometry. This method is based on basic-catalyzed hydrogen/deuterium exchange in acetone and detects the (2)H-labelled acetone directly by the headspace GC-MS. Small sample volumes and limited number of preparation steps make this method highly competitive. It has been fully validated. (2)H enriched to 8800 ppm in plasma showed an accuracy of 98.9% and %Relative Standard Deviation (RSD) of 3.1 with n = 18 over three days and with two operators. Similar performance was obtained for cerebral ISF enriched to 1100 ppm (accuracy: 96.5%, %RSD: 3.1). With this highly reproducible method we demonstrated the successful employment of (2)H2O as performance marker for a cOFM probe. Copyright © 2016. Published by Elsevier Inc.

  6. [Study of volatile organic compounds of fresh allium species using headspace combined with surface-enhanced Raman scattering].

    PubMed

    Si, Min-Zhen; Zhang, De-Qing; Liu, Ren-Ming

    2014-09-01

    In order to identify volatile organic compounds of fresh plants at room temperature and avoid sample pretreatment and extractions which can be labor intensive, garlic, Chinese chives and scallion were chopped into pieces. Then some of them were placed in the headspace vial and sealed. The gases were drawn from the vial with a syringe and were injected very slowly into Ag colloids for test using R-3000 portable Raman spectrometer. The spectra of volatile organic compounds of allium species, fresh garlic, Chinese chive and shallot plants were successfully.recorded for the first time. For garlic high intensity bands are present at 307, 399, 569, 711, 1,182, 1,287, 1,397 and 1,622 cm(-1). For Chinese chives the high intensity band is present at 672 cm(-1). Low intensity bands are present at 274, 412, 575, 1,185, 1,289, 1,396, 1,618 cm(-1). For shallot high intensity bands are present at 693 cm(-1). Lower intensity bands are present at 372, 888, 1,023 cm(-1). Low intensity bands are present at 1,088, 1,211 and 1,322 cm(-1). The SERS of diallyl disulfide, allyl methyl sulfide and 1-propanethiol in liquid state and gas state were also obtained. The main volatile organic compound of fresh garlic, Chinese chive and shallot are diallyl disulfide, allyl methyl sulfide and 1-propanethiol respectively, and the volatile organic compound of fresh onion, scallion, shallot and chive are all 1-propanethiol. The presented results illustrate that combining headspace and SERS is a powerful tool for volatile organic compound analysis in fresh plants. The volatile organic compound can be detected in fresh plant samples directly and quickly without extraction.

  7. Determination of volatile chlorinated hydrocarbons in water samples by static headspace gas chromatography with electron capture detection.

    PubMed

    Li, Tiejun; Guo, Yuanming; Hu, Hongmei; Zhang, Xiaoning; Jin, Yanjian; Zhang, Xiaojun; Zhang, Yurong

    2016-01-01

    A simple, efficient, solvent-free, and commercial readily available approach for determination of five volatile chlorinated hydrocarbons in water samples using the static headspace sampling and gas chromatography with electron capture detection has been described. The proposed static headspace sampling method was initially optimized and the optimum experimental conditions found were 10 mL water sample containing 20% w/v sodium chloride placed in a 20 mL vial and stirred at 50ºC for 20 min. The linearity of the method was in the range of 1.2-240 μg/L for dichloromethane, 0.2-40 μg/L for trichloromethane, 0.005-1 μg/L for perchloromethane, 0.025-5 μg/L for trichloroethylene, and 0.01-2 μg/L for perchloroethylene, with coefficients of determination ranging between 0.9979 and 0.9990. The limits of detection were in the low μg/L level, ranging between 0.001 and 0.3 μg/L. The relative recoveries of spiked five volatile chlorinated hydrocarbons with external calibration method at different concentration levels in pure, tap, sea water of Jiaojiang Estuary, and sea water of waters of Xiaomendao were in the range of 91-116, 96-105, 86-112, and 80-111%, respectively, and with relative standard deviations of 1.9-3.6, 2.3-3.5, 1.5-2.7, and 2.3-3.7% (n = 5), respectively. The performance of the proposed method was compared with traditional liquid-liquid extraction on the real water samples (i.e., pure, tap, and sea water, etc.) and comparable efficiencies were obtained. It is concluded that this method can be successfully applied for the determination of volatile chlorinated hydrocarbons in different water samples. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. The effect of prime emulsion components as a function of equilibrium headspace concentration of soursop flavor compounds

    PubMed Central

    2014-01-01

    Background Perceptions of food products start when flavor compounds are released from foods, transported and appropriate senses in the oral and nose are triggered. However, the long-term stability of flavor compounds in food product has been a major concern in the food industry due to the complex interactions between key food ingredients (e.g., polysaccharides and proteins). Hence, this study was conducted to formulate emulsion-based beverage using natural food emulsifiers and to understand the interactions between emulsion compositions and flavor compounds. Results The influences of modified starch (x 1 ), whey protein isolate (x 2 ), soursop flavor oil (x 3 ) and deionized water (x 4 ) on the equilibrium headspace concentration of soursop volatile flavor compounds were evaluated using a four-component with constrained extreme vertices mixture design. The results indicated that the equilibrium headspace concentration of soursop flavor compounds were significantly (p < 0.05) influenced by the matrix and structural compositions of the beverage emulsions. Interface formed using modified starch and whey protein isolate (WPI) proved to be capable of inhibiting the release of volatile flavor compounds from the oil to the aqueous phase. Modified starch could retard the overall flavor release through its hydrophobic interactions with volatile flavor compounds and viscosity enhancement effect. Excessive amount of modified starch was also shown to be detrimental to the stability of emulsion system. However, both modified starch and WPI showed to be a much more effective barrier in inhibiting the flavor release of flavor compounds when used as individual emulsifier than as a mixture. Conclusions Overall, the mixture design can be practical in elucidating the complex interactions between key food components and volatile flavor compounds in an emulsion system. These studies will be useful for the manufacturers for the formulation of an optimum beverage emulsion with

  9. Headspace versus direct immersion solid phase microextraction in complex matrixes: investigation of analyte behavior in multicomponent mixtures.

    PubMed

    Gionfriddo, Emanuela; Souza-Silva, Érica A; Pawliszyn, Janusz

    2015-08-18

    This work aims to investigate the behavior of analytes in complex mixtures and matrixes with the use of solid-phase microextraction (SPME). Various factors that influence analyte uptake such as coating chemistry, extraction mode, the physicochemical properties of analytes, and matrix complexity were considered. At first, an aqueous system containing analytes bearing different hydrophobicities, molecular weights, and chemical functionalities was investigated by using commercially available liquid and solid porous coatings. The differences in the mass transfer mechanisms resulted in a more pronounced occurrence of coating saturation in headspace mode. Contrariwise, direct immersion extraction minimizes the occurrence of artifacts related to coating saturation and provides enhanced extraction of polar compounds. In addition, matrix-compatible PDMS-modified solid coatings, characterized by a new morphology that avoids coating fouling, were compared to their nonmodified analogues. The obtained results indicate that PDMS-modified coatings reduce artifacts associated with coating saturation, even in headspace mode. This factor, coupled to their matrix compatibility, make the use of direct SPME very practical as a quantification approach and the best choice for metabolomics studies where wide coverage is intended. To further understand the influence on analyte uptake on a system where additional interactions occur due to matrix components, ex vivo and in vivo sampling conditions were simulated using a starch matrix model, with the aim of mimicking plant-derived materials. Our results corroborate the fact that matrix handling can affect analyte/matrix equilibria, with consequent release of high concentrations of previously bound hydrophobic compounds, potentially leading to coating saturation. Direct immersion SPME limited the occurrence of the artifacts, which confirms the suitability of SPME for in vivo applications. These findings shed light into the implementation of in

  10. Static headspace gas chromatography-mass spectrometry for the one-step derivatisation and extraction of eleven aldehydes in drinking water.

    PubMed

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2013-09-13

    Low-molecular-mass aldehydes (LMMAs) are water disinfection by-products formed by the reaction of ozone and/or chlorine with natural organic matter in water. LMMAs are mutagenic and carcinogenic compounds, which are detected at ng/L levels in water. An analytical method that allows simultaneous derivatisation and extraction of LMMAs in water has been developed using the classical static headspace technique coupled with gas chromatography-mass spectrometry (HS-GC-MS). Important parameters controlling the derivatisation of LMMAs with o-2,3,4,5,6-pentafluorobenzylhydroxylamine, oxime-products extraction and headspace generation were optimised to obtain the highest sensitivity, completing the entire process in 20min. For the first time the derivatisation reaction was carried out at alkaline pH adjusted with sodium hydrogen carbonate which exerts a significant enhancement effect on the derivatisation efficiency of the aldehydes; up to 20-fold with respect to those obtained in weak acid media as recommended by EPA Method 556.1. The addition of 200μL of n-hexane, as a chemical modifier, favoured the volatilisation of oxime-products, increasing the sensitivity of the method. The proposed method allows the achieving of detection limits from 2 to 80ng/L and has excellent precision (RSD average value of 6.4%) and accuracy (recovery ranging from 97% to 99%) for LMMA quantifications in drinking water samples. Finally, the HS-GC-MS method was validated relative to EPA Method 556.1 for the analysis of drinking water samples subjected to several disinfection treatments. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Hydride generation coupled to microfunnel-assisted headspace liquid-phase microextraction for the determination of arsenic with UV-Vis spectrophotometry.

    PubMed

    Hashemniaye-Torshizi, Reihaneh; Ashraf, Narges; Arbab-Zavar, Mohammad Hossein

    2014-12-01

    In this research, a microfunnel-assisted headspace liquid-phase microextraction technique has been used in combination with hydride generation to determine arsenic (As) by UV-Vis spectrophotometry. The method is based on the reduction of As to arsine (AsH3) in acidic media by sodium tetrahydroborate (NaBH4) followed by its subsequent reaction with silver diethyldithiocarbamate (AgDDC) to give an absorbing complex at 510 nm. The complexing reagent (AgDDC) has been dissolved in a 1:1 (by the volume ratio) mixture of chloroform/chlorobenzene microdroplet and exposed to the generated gaseous arsine via a reversed microfunnel in the headspace of the sample solution. Several operating parameters affecting the performance of the method have been examined and optimized. Acetonitrile solvent has been added to the working samples as a sensitivity enhancement agent. Under the optimized operating conditions, the detection limit has been measured to be 0.2 ng mL(-1) (based on 3sb/m criterion, n b = 8), and the calibration curve was linear in the range of 0.5-12 ng mL(-1). The relative standard deviation for eight replicate measurements was 1.9 %. Also, the effects of several potential interferences have been studied. The accuracy of the method was validated through the analysis of JR-1 geological standard reference material. The method has been successfully applied for the determination of arsenic in raw and spiked soft drink and water samples with the recoveries that ranged from 91 to 106 %.

  12. Accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; He, Liang

    2016-09-16

    This work reports on a method for the accurate determination of fiber water-retaining capability at process conditions by headspace gas chromatography (HS-GC) method. The method was based the HS-GC measurement of water vapor on a set closed vials containing in a given amount pulp with different amounts of water addition, from under-saturation to over-saturation. By plotting the equilibrated water vapor signal vs. the amount of water added in pulp, two different trend lines can be observed, in which the transition of the lines corresponds to fiber water-retaining capability. The results showed that the HS-GC method has good measurement precision (much better than the reference method) and good accuracy. The present method can be also used for determining pulp fiber water-retaining capability at the process temperatures in both laboratory research and mill applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Determination of glutaraldehyde in water samples by headspace solid-phase microextraction and gas chromatography-mass spectrometry after derivatization with 2,2,2-trifluoroethylhydrazine.

    PubMed

    Kang, Hye-In; Shin, Ho-Sang

    2016-05-27

    A simple and convenient headspace solid-phase microextraction (HS-SPME) gas chromatography mass spectrometry (GC-MS) method was described for the determination of glutaraldehyde in water. Glutaraldehyde in water reacted with 2,2,2-trifluoroethylhydrazine (TFEH) in a headspace vial and the formed TFEH derivatives were vaporized and adsorbed onto a fiber. The optimal HS-SPME conditions were achieved with a 50/30μm-divinylbenzene-carboxen-polydimethylsiloxane fiber, 0.06% 2,2,2-TFEH, 25% salt, an extraction/derivatization temperature of 80°C, a heating time of 30min, and a pH of 6.5. The desorption was performed for 1min at 240°C. Under the established conditions, the lowest limits of detection were 0.3μg/L and 0.1μg/L in 6.0mL of surface water and drinking water, respectively, and the intra- and inter-day relative standard deviation was less than 9.1% at concentrations of 50, 100 and 500μg/L. The calibration curve showed good linearity with R=0.9995 and R=0.9993 in surface water and drinking water, respectively. This method is simple, amenable to automation and environmentally friendly. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Results for the First, Second, and Third Quarter Calendar Year 2015 Tank 50H WAC slurry samples chemical and radionuclide contaminants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, C.

    2016-02-18

    This report details the chemical and radionuclide contaminant results for the characterization of the Calendar Year (CY) 2015 First, Second, and Third Quarter sampling of Tank 50H for the Saltstone Waste Acceptance Criteria (WAC) in effect at that time. Information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering (D&S-FE) to support the transfer of low-level aqueous waste from Tank 50H to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50H Waste Characterization System. Previous memorandamore » documenting the WAC analyses results have been issued for these three samples.« less

  15. Quantification of Neural Ethanol and Acetaldehyde Using Headspace GC-MS

    PubMed Central

    Heit, Claire; Eriksson, Peter; Thompson, David C; Fritz, Kristofer S; Vasiliou, Vasilis

    2016-01-01

    BACKGROUND There is controversy regarding the active agent responsible for alcohol addiction. The theory that ethanol itself was the agent in alcohol drinking behavior was widely accepted until acetaldehyde was found in the brain. The importance of acetaldehyde formation in the brain role is still subject to speculation due to the lack of a method to accurately assay the acetaldehyde levels directly. A highly sensitive GC-MS method to reliably determine acetaldehyde concentration with certainty is needed to address whether neural acetaldehyde is indeed responsible for increased alcohol consumption. METHODS A headspace gas chromatograph coupled to selected ion monitoring mass spectrometry was utilized to develop a quantitative assay for acetaldehyde and ethanol. Our GC-MS approach was carried out using a Bruker Scion 436-GC SQ MS. RESULTS Our approach yields limits of detection of acetaldehyde in the nanomolar range and limits of quantification in the low micromolar range. Our linear calibration includes 5 concentrations with a least square regression greater than 0.99 for both acetaldehyde and ethanol. Tissue analyses using this method revealed the capacity to quantify ethanol and acetaldehyde in blood, brain, and liver tissue from mice. CONCLUSIONS By allowing quantification of very low concentrations, this method may be used to examine the formation of ethanol metabolites, specifically acetaldehyde, in murine brain tissue in alcohol research. PMID:27501276

  16. An assessment of the liquid-gas partitioning behavior of major wastewater odorants using two comparative experimental approaches: liquid sample-based vaporization vs. impinger-based dynamic headspace extraction into sorbent tubes.

    PubMed

    Iqbal, Mohammad Asif; Kim, Ki-Hyun; Szulejko, Jan E; Cho, Jinwoo

    2014-01-01

    The gas-liquid partitioning behavior of major odorants (acetic acid, propionic acid, isobutyric acid, n-butyric acid, i-valeric acid, n-valeric acid, hexanoic acid, phenol, p-cresol, indole, skatole, and toluene (as a reference)) commonly found in microbially digested wastewaters was investigated by two experimental approaches. Firstly, a simple vaporization method was applied to measure the target odorants dissolved in liquid samples with the aid of sorbent tube/thermal desorption/gas chromatography/mass spectrometry. As an alternative method, an impinger-based dynamic headspace sampling method was also explored to measure the partitioning of target odorants between the gas and liquid phases with the same detection system. The relative extraction efficiency (in percent) of the odorants by dynamic headspace sampling was estimated against the calibration results derived by the vaporization method. Finally, the concentrations of the major odorants in real digested wastewater samples were also analyzed using both analytical approaches. Through a parallel application of the two experimental methods, we intended to develop an experimental approach to be able to assess the liquid-to-gas phase partitioning behavior of major odorants in a complex wastewater system. The relative sensitivity of the two methods expressed in terms of response factor ratios (RFvap/RFimp) of liquid standard calibration between vaporization and impinger-based calibrations varied widely from 981 (skatole) to 6,022 (acetic acid). Comparison of this relative sensitivity thus highlights the rather low extraction efficiency of the highly soluble and more acidic odorants from wastewater samples in dynamic headspace sampling.

  17. On-matrix derivatization for dynamic headspace sampling of nonvolatile surface residues.

    PubMed

    Harvey, Scott D; Wahl, Jon H

    2012-09-21

    The goal of this study is to extend sampling by the field and laboratory emission cell (FLEC) dynamic headspace technique to applications that target nonvolatile residues. On-matrix derivatization of residues to render analytes stable and more volatile is explored to achieve this goal. Results show that on-matrix derivatizations of nerve agent hydrolysis products (monoalkyl methylphosphonic acids and methylphosphonic acid [MPA]) with diazomethane were successful on glass and painted wallboard (at the 10-μg level). It also was successful on the more difficult concrete (at the 500-μg level) and carpet (at the 20-μg level), substrates that cannot be successfully sampled using swipe techniques. Analysis of additional chemical warfare (CW)-associated residues can be approached by on-matrix derivatization with trifluoroacetic anhydride (TFAA). For example, amines (used as stabilizers or present as decomposition products of the nerve agent VX) or thiodiglycol (hydrolysis product of sulfur mustard) could be sampled as their TFAA derivatives from glass, painted wallboard, and concrete (at the 40-μg level), as well as carpet (at the 80-μg level) surfaces. Although the amine and thiodiglycol are semi-volatile and could be sampled directly, derivatization improves the recovery and chromatographic behavior of these analytes. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. A Robust Static Headspace GC-FID Method to Detect and Quantify Formaldehyde Impurity in Pharmaceutical Excipients

    PubMed Central

    Al-Khayat, Mohammad Ammar; Karabet, Francois; Al-Mardini, Mohammad Amer

    2018-01-01

    Formaldehyde is a highly reactive impurity that can be found in many pharmaceutical excipients. Trace levels of this impurity may affect drug product stability, safety, efficacy, and performance. A static headspace gas chromatographic method was developed and validated to determine formaldehyde in pharmaceutical excipients after an effective derivatization procedure using acidified ethanol. Diethoxymethane, the derivative of formaldehyde, was then directly analyzed by GC-FID. Despite the simplicity of the developed method, however, it is characterized by its specificity, accuracy, and precision. The limits of detection and quantification of formaldehyde in the samples were of 2.44 and 8.12 µg/g, respectively. This method is characterized by using simple and economic GC-FID technique instead of MS detection, and it is successfully used to analyze formaldehyde in commonly used pharmaceutical excipients. PMID:29686930

  19. Results For The Third Quarter Calendar Year 2016 Tank 50H Salt Solution Sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, C.

    2016-10-13

    In this memorandum, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2016 (CY16) sample of Tank 50H salt solution are presented in tabulated form. The Third Quarter CY16 Tank 50H samples (a 200 mL sample obtained 6” below the surface (HTF-5-16-63) and a 1 L sample obtained 66” from the tank bottom (HTF-50-16-64)) were obtained on July 14, 2016 and received at Savannah River National Laboratory (SRNL) on the same day. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours, and the samples were pulled immediately after pumpmore » shut down. The information from this characterization will be used by Defense Waste Processing Facility (DWPF) & Saltstone Facility Engineering for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the Task Technical and Quality Assurance Plan (TTQAP) for the Tank 50H saltstone task. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY16 sampling of Tank 50H were requested by Savannah River Remediation (SRR) personnel and details of the testing are presented in the SRNL TTQAP.« less

  20. Liquid paraffin as new dilution medium for the analysis of high boiling point residual solvents with static headspace-gas chromatography.

    PubMed

    D'Autry, Ward; Zheng, Chao; Bugalama, John; Wolfs, Kris; Hoogmartens, Jos; Adams, Erwin; Wang, Bochu; Van Schepdael, Ann

    2011-07-15

    Residual solvents are volatile organic compounds which can be present in pharmaceutical substances. A generic static headspace-gas chromatography analysis method for the identification and control of residual solvents is described in the European Pharmacopoeia. Although this method is proved to be suitable for the majority of samples and residual solvents, the method may lack sensitivity for high boiling point residual solvents such as N,N-dimethylformamide, N,N-dimethylacetamide, dimethyl sulfoxide and benzyl alcohol. In this study, liquid paraffin was investigated as new dilution medium for the analysis of these residual solvents. The headspace-gas chromatography method was developed and optimized taking the official Pharmacopoeia method as a starting point. The optimized method was validated according to ICH criteria. It was found that the detection limits were below 1μg/vial for each compound, indicating a drastically increased sensitivity compared to the Pharmacopoeia method, which failed to detect the compounds at their respective limit concentrations. Linearity was evaluated based on the R(2) values, which were above 0.997 for all compounds, and inspection of residual plots. Instrument and method precision were examined by calculating the relative standard deviations (RSD) of repeated analyses within the linearity and accuracy experiments, respectively. It was found that all RSD values were below 10%. Accuracy was checked by a recovery experiment at three different levels. Mean recovery values were all in the range 95-105%. Finally, the optimized method was applied to residual DMSO analysis in four different Kollicoat(®) sample batches. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Application of headspace for research volatile organic compounds emitted from building materials

    NASA Astrophysics Data System (ADS)

    Kultys, Beata; Waląg, Karolina

    2018-01-01

    Headspace technique and gas chromatography method with mas detector has been used for the determination of volatile organic compounds (VOC) emitted from various building and finishing materials, such as sealing foams, mounting strips, paints, varnishes, floor coverings. The tests were carried out for different temperatures (in the temperature range of 60 to 180 °C) and the time of heated vials with tested materials inside. These tests were conducted to verify the possibility of use this method of determination the VOC emission. Interpretation of chromatograms and mass spectra allowed to identify the type of compounds emitted from the tested materials and the optimum time and temperature for each type of material was determined. The increase in heating temperature of the samples resulted in increase the type and number of identified compounds: for four materials the increase was in the whole temperature range, for others it was from 90 °C. On the other hand, emission from mineral wool was low in whole temperature range. 30-minutes heating of the samples was sufficient to identify emitted compounds for most of tested materials. Applying a longer time, i.e. 24 hours, significantly increased the sensitivity of the method.

  2. Full evaporation dynamic headspace in combination with selectable one-dimensional/two-dimensional gas chromatography-mass spectrometry for the determination of suspected fragrance allergens in cosmetic products.

    PubMed

    Devos, Christophe; Ochiai, Nobuo; Sasamoto, Kikuo; Sandra, Pat; David, Frank

    2012-09-14

    Suspected fragrance allergens were determined in cosmetic products using a combination of full evaporation-dynamic headspace (FEDHS) with selectable one-dimensional/two-dimensional GC-MS. The full evaporation dynamic headspace approach allows the non-discriminating extraction and injection of both apolar and polar fragrance compounds, without contamination of the analytical system by high molecular weight non-volatile matrix compounds. The method can be applied to all classes of cosmetic samples, including water containing matrices such as shower gels or body creams. In combination with selectable (1)D/(2)D GC-MS, consisting of a dedicated heart-cutting GC-MS configuration using capillary flow technology (CFT) and low thermal mass GC (LTM-GC), a highly flexible and easy-to-use analytical solution is offered. Depending on the complexity of the perfume fraction, analyses can be performed in one-dimensional GC-MS mode or in heart-cutting two-dimensional GC-MS mode, without the need of hardware reconfiguration. The two-dimensional mode with independent temperature control of the first and second dimension column is especially useful to confirm the presence of detected allergen compounds when mass spectral deconvolution is not possible. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Fast and solvent-free quantitation of boar taint odorants in pig fat by stable isotope dilution analysis-dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry.

    PubMed

    Fischer, Jochen; Haas, Torsten; Leppert, Jan; Lammers, Peter Schulze; Horner, Gerhard; Wüst, Matthias; Boeker, Peter

    2014-09-01

    Boar taint is a specific off-odour of boar meat products, known to be caused by at least three unpleasant odorants, with very low odour thresholds. Androstenone is a boar pheromone produced in the testes, whereas skatole and indole originate from the microbial breakdown of tryptophan in the intestinal tract. A new procedure, applying stable isotope dilution analysis (SIDA) and dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry (dynHS-TD-GC/TOFMS) for the simultaneous quantitation of these boar taint compounds in pig fat was elaborated and validated in this paper. The new method is characterised by a simple and solvent-free dynamic headspace sampling. The deuterated compounds d3-androstenone, d3-skatole and d6-indole were used as internal standards to eliminate matrix effects. The method validation performed revealed low limits of detection (LOD) and quantitation (LOQ) with high accuracy and precision, thus confirming the feasibility of the new dynHS-TD-GC/TOFMS approach for routine analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Identification of volatiles by headspace gas chromatography with simultaneous flame ionization and mass spectrometric detection.

    PubMed

    Tiscione, Nicholas B; Yeatman, Dustin Tate; Shan, Xiaoqin; Kahl, Joseph H

    2013-10-01

    Volatiles are frequently abused as inhalants. The methods used for identification are generally nonspecific if analyzed concurrently with ethanol or require an additional analytical procedure that employs mass spectrometry. A previously published technique utilizing a capillary flow technology splitter to simultaneously quantitate and confirm ethyl alcohol by flame ionization and mass spectrometric detection after headspace sampling and gas chromatographic separation was evaluated for the detection of inhalants. Methanol, isopropanol, acetone, acetaldehyde, toluene, methyl ethyl ketone, isoamyl alcohol, isobutyl alcohol, n-butyl alcohol, 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane (Norflurane, HFC-134a), chloroethane, trichlorofluoromethane (Freon®-11), dichlorodifluoromethane (Freon®-12), dichlorofluoromethane (Freon®-21), chlorodifluoromethane (Freon®-22) and 1,2-dichlorotetrafluoroethane (Freon®-114) were validated for qualitative identification by this method. The validation for qualitative identification included evaluation of matrix effects, sensitivity, carryover, specificity, repeatability and ruggedness/robustness.

  5. Analysis of Listeria using exogenous volatile organic compound metabolites and their detection by static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS).

    PubMed

    Taylor, Carl; Lough, Fraser; Stanforth, Stephen P; Schwalbe, Edward C; Fowlis, Ian A; Dean, John R

    2017-07-01

    Listeria monocytogenes is a Gram-positive bacterium and an opportunistic food-borne pathogen which poses significant risk to the immune-compromised and pregnant due to the increased likelihood of acquiring infection and potential transmission of infection to the unborn child. Conventional methods of analysis suffer from either long turn-around times or lack the ability to discriminate between Listeria spp. reliably. This paper investigates an alternative method of detecting Listeria spp. using two novel enzyme substrates that liberate exogenous volatile organic compounds in the presence of α-mannosidase and D-alanyl aminopeptidase. The discriminating capabilities of this approach for identifying L. monocytogenes from other species of Listeria are investigated. The liberated volatile organic compounds (VOCs) are detected using an automated analytical technique based on static headspace-multi-capillary column-gas chromatography-ion mobility spectrometry (SHS-MCC-GC-IMS). The results obtained by SHS-MCC-GC-IMS are compared with those obtained by the more conventional analytical technique of headspace-solid phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The results found that it was possible to differentiate between L. monocytogenes and L. ivanovii, based on their VOC response from α-mannosidase activity.

  6. Determination of some volatile compounds in alcoholic beverage by headspace solid-phase microextraction gas chromatography - mass spectrometry

    NASA Astrophysics Data System (ADS)

    Schmutzer, G.; Avram, V.; Feher, I.; David, L.; Moldovan, Z.

    2012-02-01

    The volatile composition of alcoholic beverage was studied by headspace solid-phase microextraction (HSSPME) method and gas chromatography - mass spectrometry (GC-MS). Some volatile compounds, such as alcohols, esters, terpenes and other are mainly responsible for the flavor of fortified wines and their amounts specify the quality of the alcoholic beverages. From this perspective it is interesting to develop a rapid, selective and sensitive analytical method suitable for simultaneous quantification of the main molecules being responsible for the organoleptic characteristic of alcoholic beverages. Vermouth fortified drink was analyzed in order to characterize the volatile profile. Using the HS-SPME/GC-MS a number of twenty-six volatile compounds from a commercial market alcoholic beverage were identified. The most abundant compounds were m-thymol, o-thymol and eugenol, alongside of the ethyl ester compounds.

  7. Analysis of iodide and iodate in Lake Mead, Nevada using a headspace derivatization gas chromatography-mass spectrometry.

    PubMed

    Dorman, James W; Steinberg, Spencer M

    2010-02-01

    We report here a derivatization headspace method for the analysis of inorganic iodine in water. Samples from Lake Mead, the Las Vegas Wash, and from Las Vegas tap water were examined. Lake Mead and the Las Vegas Wash contained a mixture of both iodide and iodate. The average concentration of total inorganic iodine (TII) for Lake Mead was approximately 90 nM with an iodide-to-iodate ratio of approximately 1. The TII concentration (approximately 160 nM) and the ratio of iodide to iodate were higher for the Las Vegas Wash (approximately 2). The TII concentration for tap water was close to that of Lake Mead (approximately 90 nM); however, tap water contained no detectable iodide as a result of ozonation and chlorine treatment which converts all of the iodide to iodate.

  8. An analytical method for trifluoroacetic Acid in water and air samples using headspace gas chromatographic determination of the methyl ester.

    PubMed

    Zehavi, D; Seiber, J N

    1996-10-01

    An analytical method has been developed for the determination of trace levels of trifluoroacetic acid (TFA), an atmospheric breakdown product of several of the hydrofluorocarbon (HFC) and hydrochlorofluorocarbon (HCFC) replacements for the chlorofluorocarbon (CFC) refrigerants, in water and air. TFA is derivatized to the volatile methyl trifluoroacetate (MTFA) and determined by automated headspace gas chromatography (HSGC) with electron-capture detection or manual HSGC using GC/MS in the selected ion monitoring (SIM) mode. The method is based on the reaction of an aqueous sample containing TFA with dimethyl sulfate (DMS) in concentrated sulfuric acid in a sealed headspace vial under conditions favoring distribution of MTFA to the vapor phase. Water samples are prepared by evaporative concentration, during which TFA is retained as the anion, followed by extraction with diethyl ether of the acidified sample and then back-extraction of TFA (as the anion) in aqueous bicarbonate solution. The extraction step is required for samples with a relatively high background of other salts and organic materials. Air samples are collected in sodium bicarbonate-glycerin-coated glass denuder tubes and prepared by rinsing the denuder contents with water to form an aqueous sample for derivatization and analysis. Recoveries of TFA from spiked water, with and without evaporative concentration, and from spiked air were quantitative, with estimated detection limits of 10 ng/mL (unconcentrated) and 25 pg/mL (concentrated 250 mL:1 mL) for water and 1 ng/m(3) (72 h at 5 L/min) for air. Several environmental air, fogwater, rainwater, and surface water samples were successfully analyzed; many showed the presence of TFA.

  9. Headspace gas chromatographic method for the measurement of difluoroethane in blood.

    PubMed

    Broussard, L A; Broussard, A; Pittman, T; Lafferty, D; Presley, L

    2001-01-01

    To develop a gas chromatographic assay for the analysis of difluoroethane, a volatile substance, in blood and to determine assay characteristics including linearity, limit of quantitation, precision, and specificity. Referral toxicology laboratory Difluoroethane, a colorless, odorless, highly flammable gas used as a refrigerant blend component and aerosol propellant, may be abused via inhalation. A headspace gas chromatographic procedure for the identification and quantitation of difluoroethane in blood is presented. A methanolic stock standard prepared from pure gaseous difluoroethane was used to prepare whole blood calibrators. Quantitation of difluoroethane was performed using a six-point calibration curve and an internal standard of 1-propanol. The assay is linear from 0 to 115 mg/L including a low calibrator at 4 mg/L, the limit of quantitation. Within-run coefficients of variation at mean concentrations of 13.8 mg/L and 38.5 mg/L were 5.8% and 6.8% respectively. Between-run coefficients of variation at mean concentrations of 15.9 mg/L and 45.7 mg/L were 13.4% and 9.8% respectively. Several volatile substances were tested as potential interfering compounds with propane having a retention time identical to that of difluoroethane. This method requires minimal sample preparation, is rapid and reproducible, can be modified for the quantitation of other volatiles, and could be automated using an automatic sampler/injector system.

  10. Headspace Analysis of Philippine Civet Coffee Beans Using Gas Chromatography-Mass Spectrometry and Electronic Nose

    NASA Astrophysics Data System (ADS)

    Ongo, E.; Sevilla, F.; Antonelli, A.; Sberveglieri, G.; Montevecchi, G.; Sberveglieri, V.; de Paola, E. L.; Concina, I.; Falasconi, M.

    2011-11-01

    Civet coffee, the most expensive and best coffee in the world, is an economically important export product of the Philippines. With a growing threat of food adulteration and counterfeiting, a need for quality authentication is essential to protect the integrity and strong market value of Philippine civet coffee. At present, there is no internationally accepted method of verifying whether a bean is an authentic civet coffee. This study presented a practical and promising approach to identify and establish the headspace qualitative profile of Philippine civet coffee using electronic nose (E-nose) and gas chromatography-mass spectrometry (GC-MS). E-nose analysis revealed that aroma characteristic is one of the most important quality indicators of civet coffee. The findings were supported by GC-MS analysis. Principal component analysis (PCA) exhibited a clearly separated civet coffees from their control beans. The chromatographic fingerprints indicated that civet coffees differed with their control beans in terms of composition and concentration of individual volatile constituents.

  11. A volatile tracer-assisted headspace analytical technique for determining the swelling capacity of superabsorbent polymers.

    PubMed

    Zhang, Shu-Xin; Jiang, Ran; Chai, Xin-Sheng

    2017-09-01

    This paper reports on a new method for the determination of swelling capacity of superabsorbent polymers by a volatile tracer-assisted headspace gas chromatography (HS-GC). Toluene was used as a tracer and added to the solution for polymers swelling test. Based on the differences of the tracer partitioned between the vapor and hydrogel phase before and after the polymer's swelling capacity, a transition point (corresponding to the material swelling capacity) can be observed when plotting the GC signal of toluene vs. the ratio of solution added to polymers. The present method has good precision (RSD<2.1%) and good accuracy, in which the relative deference between the data measured by the HS-GC method and the reference method were within 8.0%. The present method is very suitable to be used for testing the swelling capacity of polymers at the elevated temperatures. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Static headspace gas chromatographic method for quantitative determination of residual solvents in pharmaceutical drug substances according to european pharmacopoeia requirements.

    PubMed

    Otero, Raquel; Carrera, Guillem; Dulsat, Joan Francesc; Fábregas, José Luís; Claramunt, Juan

    2004-11-19

    A static headspace (HS) gas chromatographic method for quantitative determination of residual solvents in a drug substance has been developed according to European Pharmacopoeia general procedure. A water-dimethylformamide mixture is proposed as sample solvent to obtain good sensitivity and recovery. The standard addition technique with internal standard quantitation was used for ethanol, tetrahydrofuran and toluene determination. Validation was performed within the requirements of ICH validation guidelines Q2A and Q2B. Selectivity was tested for 36 solvents, and system suitability requirements described in the European Pharmacopoeia were checked. Limits of detection and quantitation, precision, linearity, accuracy, intermediate precision and robustness were determined, and excellent results were obtained.

  13. Gas-Purged Headspace Liquid Phase Microextraction System for Determination of Volatile and Semivolatile Analytes

    PubMed Central

    Zhang, Meihua; Bi, Jinhu; Yang, Cui; Li, Donghao; Piao, Xiangfan

    2012-01-01

    In order to achieve rapid, automatic, and efficient extraction for trace chemicals from samples, a system of gas-purged headspace liquid phase microextraction (GP-HS-LPME) has been researched and developed based on the original HS-LPME technique. In this system, semiconductor condenser and heater, whose refrigerating and heating temperatures were controlled by microcontroller, were designed to cool the extraction solvent and to heat the sample, respectively. Besides, inert gas, whose gas flow rate was adjusted by mass flow controller, was continuously introduced into and discharged from the system. Under optimized parameters, extraction experiments were performed, respectively, using GP-HS-LPME system and original HS-LPME technique for enriching volatile and semivolatile target compounds from the same kind of sample of 15 PAHs standard mixture. GC-MS analysis results for the two experiments indicated that a higher enrichment factor was obtained from GP-HS-LPME. The enrichment results demonstrate that GP-HS-LPME system is potential in determination of volatile and semivolatile analytes from various kinds of samples. PMID:22448341

  14. A novel poly(3,4-ethylenedioxythiophene)-ionic liquid composite coating for the headspace solid-phase microextraction and gas chromatography determination of several alcohols in soft drinks.

    PubMed

    Wu, Mian; Zhang, Haibo; Zhao, Faqiong; Zeng, Baizhao

    2014-11-19

    A novel poly(3,4-ethylenedioxythiophene)-ionic liquid (i.e., 1-hydroxyethyl-3-methyl imidazolium-bis[(trifluoromethyl)sulfonyl]imide) composite film was electrodeposited on a Pt wire for headspace solid-phase microextraction. The film showed nodular structure and had large specific surface. In addition, it displayed high thermal stability (up to 300°C) and durable property (could be used for more than 200 times). Coupled with gas chromatography-flame ionization detection, the resulting fiber was applied to the headspace solid-phase microextraction and determination of several alcohols (i.e., linalool, nonanol, terpineol, geraniol, decanol and dodecanol). It presented higher extraction capability in comparison with the poly(3,4-ethylenedioxythiophene) and commercial polydimethylsiloxane/divinylbenzene fiber. Under the optimized conditions, the linear ranges exceeded three magnitudes with correlation coefficients above 0.9952 and the low limits of detection were 34.2-81.3ng L(-1). For different alcohols the repeatabilities (defined as RSD) were <5.8% and <7.8% for single fiber (n=5) and fiber-to-fiber (n=4), respectively. The proposed method was applied to the determination of these alcohols in real samples with acceptable recoveries from 81.1% to 106.6%. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Discrimination of smokeless powders by headspace SPME-GC-MS and SPME-GC-ECD, and the potential implications upon training canine detection of explosives

    NASA Astrophysics Data System (ADS)

    Harper, Ross J.; Almirall, Jose R.; Furton, Kenneth G.

    2005-05-01

    This presentation will provide an odour analysis of a variety of smokeless powders & communicate the rapid SPME-GC-ECD method utilized. This paper will also discuss the implications of the headspace analysis of Smokeless Powders upon the choice of training aids for Explosives Detection Canines. Canine detection of explosives relies upon the dogs" ability to equate finding a given explosive odour with a reward, usually in the form of praise or play. The selection of explosives upon which the dogs are trained thus determines which explosives the canines can and potentially cannot find. Commonly, the training is focussed towards high explosives such as TNT and Composition 4, and the low explosives such as Black and Smokeless Powders are added often only for completeness. Powder explosives constitute a major component of explosive incidents throughout the US, and canines trained to detect explosives must be trained across the entire range of powder products. Given the variability in the manufacture and product make-up many smokeless powders do not share common odour chemicals, giving rise to concerns over the extensiveness of canine training. Headspace analysis of a selection of Smokeless Powders by Solid Phase Microextraction Gas Chromatography using Mass Spectrometry (SPME-GC-MS) and Electron Capture Detectors (SPME-GC-ECD) has highlighted significant differences in the chemical composition of the odour available from different brands. This suggests that greater attention should be paid towards the choice of Powder Explosives when assigning canine training aids.

  16. Preparation and application of carbon nanotubes/poly(o-toluidine) composite fibers for the headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes.

    PubMed

    Behzadi, Mansoureh; Noroozian, Ebrahim; Mirzaei, Mohammad

    2013-11-01

    A novel nanocomposite coating of poly(o-toluidine) and oxidized multiwalled CNTs (MWCNTs, where CNTs is carbon nanotubes) was electrochemically prepared on a stainless-steel wire. The applicability of the fiber was assessed for the headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in aqueous samples followed by GC with flame ionization detection. In order to obtain an adherent and stable composite coating, several experimental parameters related to the coating process, such as polymerization potential and time, and the concentration of o-toluidine and oxidized MWCNTs were optimized. The combination of MWCNTs and polymer in a nanocomposite form presents desirable opportunities to produce materials for new applications. The effects of various parameters on the efficiency of the headspace solid-phase microextraction process, such as desorption temperature and time, extraction temperature and time, and ionic strength were also investigated. At the optimum conditions, LODs were 0.03-0.06 μg/L. The method showed linearity in the range of 0.5-300 μg/L with coefficients of determination >0.99. The intraday and interday RSDs obtained at a 5 μg/L concentration level (n = 5) using a single fiber were 1.2-5.2 and 3.2-7.5%, respectively. The fiber-to-fiber RSD (%; n = 3) at 5 μg/L was 6.1-9.2%. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Extraction and preconcentration of residual solvents in pharmaceuticals using dynamic headspace-liquid phase microextraction and their determination by gas chromatography-flame ionization detection.

    PubMed

    Farajzadeh, Mir Ali; Dehghani, Hamideh; Yadeghari, Adeleh; Khoshmaram, Leila

    2017-02-01

    The present study describes a microextraction and determination method for analyzing residual solvents in pharmaceutical products using dynamic headspace-liquid phase microextraction technique followed by gas chromatography-flame ionization detection. In this method dimethyl sulfoxide (μL level) placed into a GC liner-shaped extraction vessel is used as a collection/extraction solvent. Then the liner is exposed to the headspace of a vial containing the sample solution. The effect of different parameters influencing the microextraction procedure including collection/extraction solvent type and its volume, ionic strength, extraction time, extraction temperature and concentration of NaOH solution used in dissolving the studied pharmaceuticals are investigated and optimized. Under the optimum extraction conditions, the method showed wide linear ranges between 0.5 and 5000 mg L -1 . The other analytical parameters were obtained in the following ranges: enrichment factors 240-327, extraction recoveries 72-98% and limits of detection 0.1-0.8 mg L -1 in solution and 0.6-3.2 μg g -1 in solid. Relative standard deviations for the extraction of 100 mg L -1 of each analyte were obtained in the ranges of 4-7 and 5-8% for intra-day (n = 6) and inter-day (n = 4) respectively. Finally the target analytes were determined in different samples such as erythromycin, azithromycin, cefalexin, amoxicillin and co-amoxiclav by the proposed method. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Headspace screening: A novel approach for fast quality assessment of the essential oil from culinary sage.

    PubMed

    Cvetkovikj, Ivana; Stefkov, Gjoshe; Acevska, Jelena; Karapandzova, Marija; Dimitrovska, Aneta; Kulevanova, Svetlana

    2016-07-01

    Quality assessment of essential oil (EO) from culinary sage (Salvia officinalis L., Lamiaceae) is limited by the long pharmacopoeial procedure. The aim of this study was to employ headspace (HS) sampling in the quality assessment of sage EO. Different populations (30) of culinary sage were assessed using GC/FID/MS analysis of the hydrodistilled EO (pharmacopoeial method) and HS sampling directly from leaves. Compound profiles from both procedures were evaluated according to ISO 9909 and GDC standards for sage EO quality, revealing compliance for only 10 populations. Factors to convert HS values, for the target ISO and GDC components, into theoretical EO values were calculated. Statistical analysis revealed a significant relationship between HS and EO values for seven target components. Consequently, HS sampling could be used as a complementary extraction technique for rapid screening in quality assessment of sage EOs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2011-01-01

    This article presents summaries of three articles relevant to school crisis response: (1) "Factors Contributing to Posttraumatic Growth," summarized by Steve DeBlois; (2) "Psychological Debriefing in Cross-Cultural Contexts" (Stacey Rice); and (3) "Brain Abnormalities in PTSD" (Sunny Windingstad). The first summary reports the findings of a…

  20. Utilizing two detectors in the measurement of trichloroacetic acid in human urine by reaction headspace gas chromatography.

    PubMed

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-05-16

    A reaction headspace gas chromatography (HS-GC) technique was investigated for quantitatively analyzing trichloroacetic acid in human urine. This method is based on the decomposition reaction of trichloroacetic acid under high-temperature conditions. The carbon dioxide and chloroform formed from the decomposition reaction can be respectively detected by the thermal conductivity detection HS-GC and flame ionization detection HS-GC. The reaction can be completed in 60 min at 90°C. This method was used to quantify 25 different human urine samples, which had a range of trichloroacetic acid from 0.52 to 3.47 mg/L. It also utilized two different detectors, the thermal conductivity detector and the flame ionization detector. The present reaction HS-GC method is accurate, reliable and well suitable for batch detection of trichloroacetic acid in human urine. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Headspace Single-Drop Microextraction Gas Chromatography Mass Spectrometry for the Analysis of Volatile Compounds from Herba Asari

    PubMed Central

    Wang, Guan-Jie; Tian, Li; Fan, Yu-Ming; Qi, Mei-Ling

    2013-01-01

    A rapid headspace single-drop microextraction gas chromatography mass spectrometry (SDME-GC-MS) for the analysis of the volatile compounds in Herba Asari was developed in this study. The extraction solvent, extraction temperature and time, sample amount, and particle size were optimized. A mixed solvent of n-tridecane and butyl acetate (1 : 1) was finally used for the extraction with sample amount of 0.750 g and 100-mesh particle size at 70°C for 15 min. Under the determined conditions, the pound samples of Herba Asari were directly applied for the analysis. The result showed that SDME-GC–MS method was a simple, effective, and inexpensive way to measure the volatile compounds in Herba Asari and could be used for the analysis of volatile compounds in Chinese medicine. PMID:23607049

  2. Hydrophilic magnetic ionic liquid for magnetic headspace single-drop microextraction of chlorobenzenes prior to thermal desorption-gas chromatography-mass spectrometry.

    PubMed

    Fernández, Elena; Vidal, Lorena; Canals, Antonio

    2017-11-23

    A new, fast, easy to handle, and environmentally friendly magnetic headspace single-drop microextraction (Mag-HS-SDME) based on a magnetic ionic liquid (MIL) as an extractant solvent is presented. A small drop of the MIL 1-ethyl-3-methylimidazolium tetraisothiocyanatocobaltate(II) ([Emim] 2 [Co(NCS) 4 ]) is located on one end of a small neodymium magnet to extract nine chlorobenzenes (1,2-dichlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2,3-trichlorobenzene, 1,2,4-trichlorobenzene, 1,3,5-trichlorobenzene, 1,2,3,4-tetrachlorobenzene, 1,2,4,5-tetrachlorobenzene, and pentachlorobenzene) as model analytes from water samples prior to thermal desorption-gas chromatography-mass spectrometry determination. A multivariate optimization strategy was employed to optimize experimental parameters affecting Mag-HS-SDME. The method was evaluated under optimized extraction conditions (i.e., sample volume, 20 mL; MIL volume, 1 μL; extraction time, 10 min; stirring speed, 1500 rpm; and ionic strength, 15% NaCl (w/v)), obtaining a linear response from 0.05 to 5 μg L -1 for all analytes. The repeatability of the proposed method was evaluated at 0.7 and 3 μg L -1 spiking levels and coefficients of variation ranged between 3 and 18% (n = 3). Limits of detection were in the order of nanograms per liter ranging from 4 ng L -1 for 1,4-dichlorobenzene and 1,2,3,4-tetrachlorobenzene to 8 ng L -1 for 1,2,4,5-tetrachlorobenzene. Finally, tap water, pond water, and wastewater were selected as real water samples to assess the applicability of the method. Relative recoveries varied between 82 and 114% showing negligible matrix effects. Graphical abstract Magnetic headspace single-drop microextraction followed by thermal desorption-gas chromatography-mass spectrometry.

  3. Identification of volatiles in leaves of Alpinia zerumbet 'Variegata' using headspace solid-phase microextraction-gas chromatography-mass spectrometry.

    PubMed

    Chen, Jian Yan; Ye, Zheng Mei; Huang, Tian Yi; Chen, Xiao Dan; Li, Yong Yu; Wu, Shao Hua

    2014-07-01

    Alpinia zerumbet 'Variegata' is an aromatic medicinal plant, its foliage producing an intense, unique fragrant odor. This study identified 46 volatile compounds in the leaf tissue of this plant using headspace solid-phase microextraction-gas chromatography-mass spectrometry (HS-SPME-GC-MS). The major compounds included 1, 8-cineole (43.5%), p-cymene (14.7%), humulene (5.5%), camphor (5.3%), linalool (4.7%), (E)-methyl cinnamate (3.8%), gamma-cadinene (3.3%), humulene oxide II (2.1%) and a-terpineol (1.5%). The majority of the volatiles were terpenoids of which oxygenated monoterpenes were the most abundant, accounting for 57.2% of the total volatiles. Alcohols made up the largest (52.8%) and aldehydes the smallest (0.2%) portions of the volatiles. Many bioactive compounds were present in the volatiles.

  4. Odorant Metabolism Analysis by an Automated Ex Vivo Headspace Gas-Chromatography Method.

    PubMed

    Faure, Philippe; Legendre, Arièle; Hanser, Hassan-Ismail; Andriot, Isabelle; Artur, Yves; Guichard, Elisabeth; Coureaud, Gérard; Heydel, Jean-Marie

    2016-01-01

    In the olfactory epithelium (OE), odorant metabolizing enzymes have the dual function of volatile component detoxification and active clearance of odorants from the perireceptor environment to respectively maintain the integrity of the tissues and the sensitivity of the detection. Although emphasized by recent studies, this enzymatic mechanism is poorly documented in mammals. Thus, olfactory metabolism has been characterized mainly in vitro and for a limited number of odorants. The automated ex vivo headspace gas-chromatography method that was developed here was validated to account for odorant olfactory metabolism. This method easily permits the measurement of the fate of an odorant in the OE environment, taking into account the odorant gaseous state and the cellular structure of the tissue, under experimental conditions close to physiological conditions and with a high reproducibility. We confirmed here our previous results showing that a high olfactory metabolizing activity of the mammary pheromone may be necessary to maintain a high level of sensitivity toward this molecule, which is critical for newborn rabbit survival. More generally, the method that is presented here may permit the screening of odorants metabolism alone or in mixture or studying the impact of aging, pathology, polymorphism or inhibitors on odorant metabolism. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Method and apparatus for pyrolysis--porous layer open tubular column--cryoadsorption headspace sampling and analysis.

    PubMed

    Bruno, Thomas J; Nichols, Jessica E

    2013-04-19

    In previous work, dynamic headspace vapor collection on short, porous layer open tubular (PLOT) capillary columns maintained at low temperature was introduced. In this paper, that metrology is extended with the introduction of a small in situ pyrolysis platform that provides for rapid heating and rapid vapor capture for a wide variety of samples. The new approach is referred to as pyro-PLOT-cryo. The pyrolysis platform is made from two small copper lead wires that hold a basket formed from small diameter, high resistance stainless steel or NiCr wire. The basket is formed to accept a small sample, the mass of which can typically range from 0.2 to 0.05 mg. The pyrolysis is performed by use of a resistor capacitor circuit of the type used in spot welders. We have provided examples of the application of this technique with the analysis of facial cosmetics, plastic explosives, organometallic gasoline additives, polymers, and in micro scale chemical reactions. Additional modifications and future work are also discussed. Published by Elsevier B.V.

  6. Characterization of aroma compounds in apple cider using solvent-assisted flavor evaporation and headspace solid-phase microextraction.

    PubMed

    Xu, Yan; Fan, Wenlai; Qian, Michael C

    2007-04-18

    The aroma-active compounds in two apple ciders were identified using gas chromatography-olfactometry (GC-O) and GC-mass spectrometry (MS) techniques. The volatile compounds were extracted using solvent-assisted flavor evaporation (SAFE) and headspace solid-phase microextraction (HS-SPME). On the basis of odor intensity, the most important aroma compounds in the two apple cider samples were 2-phenylethanol, butanoic acid, octanoic acid, 2-methylbutanoic acid, 2-phenylethyl acetate, ethyl 2-methylbutanoate, ethyl butanoate, ethyl hexanoate, 4-ethylguaiacol, eugenol, and 4-vinylphenol. Sulfur-containing compounds, terpene derivatives, and lactones were also detected in ciders. Although most of the aroma compounds were common in both ciders, the aroma intensities were different. Comparison of extraction techniques showed that the SAFE technique had a higher recovery for acids and hydroxy-containing compounds, whereas the HS-SPME technique had a higher recovery for esters and highly volatile compounds.

  7. Determination of Lactones in Wines by Headspace Solid-Phase Microextraction and Gas Chromatography Coupled with Mass Spectrometry

    PubMed Central

    Pérez-Olivero, S. J.; Pérez-Pont, M. L.; Conde, J. E.; Pérez-Trujillo, J. P.

    2014-01-01

    Application of headspace solid-phase microextraction (HS-SPME) coupled with high-resolution gas chromatographic (HRGC) analysis was studied for determining lactones in wines. Six different SPME fibers were tested, and the influence of different factors such as temperature and time of desorption, ionic strength, time of extraction, content of sugar, ethanol, tannins and anthocyanins, and pH and influence of SO2 were studied. The proposed HS-SPME-GC method is an appropriate technique for the quantitative analysis of γ-butyrolactone, γ-hexalactone, trans-whiskey lactone, γ-octalactone, cis-whiskey lactone, γ-nonalactone, γ-decalactone, δ-decalactone, and γ-undecalactone in wines. Method reproducibility and repeatability ranged between 0.6 and 5.2% for all compounds. Detection limit for γ-butyrolactone was 0.17 mg/L and a few μg/L for the rest of the compounds. The optimized method has been applied to several wine samples. PMID:24782943

  8. [Simultaneous determination of seven residual solvents in bovis calculus artifactus by headspace gas chromatography].

    PubMed

    Chi, Shuyao; Wu, Dike; Sun, Jinhong; Ye, Ruhan; Wang, Xiaoyan

    2014-05-01

    A headspace gas chromatography (HS-GC) method was developed for the simultaneous determination of seven residual solvents (petroleum ether (60-90 degrees C), acetone, ethyl acetate, methanol, methylene chloride, ethanol and butyl acetate) in bovis calculus artifactus. The DB-WAX capillary column and flame ionization detector (FID) were used for the separation and detection of the residual solvents, and the internal standard method was used for the quantification. The chromatographic conditions, such as equilibrium temperature and equilibrium time, were optimized. Under the optimized conditions, all of the seven residual solvents showed good linear relationships with good correlation coefficients (not less than 0.999 3) in the prescribed concentration range. At three spiked levels, the recoveries for the seven residual solvents were 94.7%-105.2% with the relative standard deviations (RSDs) less than 3.5%. The limits of detection (LODs) of the method were 0.43-5.23 mg/L, and the limits of quantification (LOQs) were 1.25-16.67 mg/L. The method is simple, rapid, sensitive and accurate, and is suitable for the simultaneous determination of the seven residual solvents in bovis calculus artifactus.

  9. Ethanol analysis by headspace gas chromatography with simultaneous flame-ionization and mass spectrometry detection.

    PubMed

    Tiscione, Nicholas B; Alford, Ilene; Yeatman, Dustin Tate; Shan, Xiaoqin

    2011-09-01

    Ethanol is the most frequently identified compound in forensic toxicology. Although confirmation involving mass spectrometry is desirable, relatively few methods have been published to date. A novel technique utilizing a Dean's Switch to simultaneously quantitate and confirm ethyl alcohol by flame-ionization (FID) and mass spectrometric (MS) detection after headspace sampling and gas chromatographic separation is presented. Using 100 μL of sample, the limits of detection and quantitation were 0.005 and 0.010 g/dL, respectively. The zero-order linear range (r(2) > 0.990) was determined to span the concentrations of 0.010 to 1.000 g/dL. The coefficient of variation of replicate analyses was less than 3.1%. Quantitative accuracy was within ±8%, ±6%, ±3%, and ±1.5% at concentrations of 0.010, 0.025, 0.080, and 0.300 g/dL, respectively. In addition, 1,1-difluoroethane was validated for qualitative identification by this method. The validated FID-MS method provides a procedure for the quantitation of ethyl alcohol in blood by FID with simultaneous confirmation by MS and can also be utilized as an identification method for inhalants such as 1,1-difluoroethane.

  10. Analysis of endogenous aldehydes in human urine by static headspace gas chromatography-mass spectrometry.

    PubMed

    Serrano, María; Gallego, Mercedes; Silva, Manuel

    2016-03-11

    Endogenous aldehydes (EAs) generated during oxidative stress and cell processes are associated with many pathogenic and toxicogenic processes. The aim of this research was to develop a solvent-free and automated analytical method for the determination of EAs in human urine using a static headspace generator sampler coupled with gas chromatography-mass spectrometry (HS-GC-MS). Twelve significant EAs used as markers of different biochemical and physiological processes, namely short- and medium-chain alkanals, α,β-unsaturated aldehydes and dicarbonyl aldehydes have been selected as target analytes. Human urine samples (no dilution is required) were derivatized with O-2,3,4,5,6-pentafluorobenzylhydroxylamine in alkaline medium (hydrogen carbonate-carbonate buffer, pH 10.3). The HS-GC-MS method developed renders an efficient tool for the sensitive and precise determination of EAs in human urine with limits of detection from 1 to 15ng/L and relative standard deviations, (RSDs) from 6.0 to 7.9%. Average recoveries by enriching urine samples ranged between 92 and 95%. Aldehydes were readily determined at 0.005-50μg/L levels in human urine from healthy subjects, smokers and diabetic adults. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Headspace sorptive solid phase microextraction (HS-SPME) combined with a spectrophotometry system: A simple glass devise for extraction and simultaneous determination of cyanide and thiocyanate in environmental and biological samples.

    PubMed

    Al-Saidi, H M; Al-Harbi, Sami A; Aljuhani, E H; El-Shahawi, M S

    2016-10-01

    A simple, low cost and efficient headspace sorptive solid phase microextraction (HS-SPME) method for determination of cyanide has been developed. The system comprises of a glass tube with two valves and a moveable glass slide fixed at its centre. It includes an acceptor phase polyurethane foam treated mercury (II) dithizonate [Hg(HDz)2-PUF] complex fixed inside by a septum cap in a cylindrical configuration (5.0cm length and 1.0cm diameter). The extraction is based upon the contact of the acceptor phase to the headspace and subsequently measuring the absorbance of the recovered mercury (II) dithizonate from PUFs sorbent. Unlike other HSSE, extraction and back - extractions was carried out in a closed system, thereby improving the analytical performance by preventing the analyte loss. Under the optimized conditions, a linear calibration plot in the range of 1.0-50.0µmolL(-1) was achieved with limits of detection (LOD) and quantification (LOQ) of 0.34, 1.2µmolL(-1) CN(-), respectively. Simultaneous analysis of cyanide and thiocyanate in saliva was also performed with satisfactory recoveries. Copyright © 2016. Published by Elsevier B.V.

  12. Serum Headspace Analysis With An Electronic Nose And Comparison With Clinical Signs Following Experimental Infection Of Cattle With Mannheimia Haemolytica

    NASA Astrophysics Data System (ADS)

    Knobloch, Henri; Turner, Claire; Chambers, Mark; Reinhold, Petra

    2009-05-01

    Electronic noses (e-noses) have been widely used for medical applications or in the food industry. However, little is known about their utility for early disease detection in animals. In this study, 20 calves were experimentally infected with Mannheimia haemolytica A1. Blood serum was collected from 7 days before infection to 5 days after infection and headspace of sera was analysed using the ST214 (Scensive Tech. Ltd., Leeds, UK) e-nose. Differences between pre- and post infection status were investigated and a temporal profile of sensor responses was compared with body temperature over the course of infection. A similar profile for sensor responses and body temperature indicated the e-nose was detecting a genuine physiological response following infection.

  13. NASA Information Summaries.

    ERIC Educational Resources Information Center

    Mar, May 1987, 1988

    1988-01-01

    This document consists of 11 "NASA Information Summaries" grouped together: (1) "Our Planets at a Glance" (PMS-010); (2) "Space Shuttle Mission Summary: 1985-1986" (PMS-005); (3) "Astronaut Selection and Training" (PMS-019); (4) "Space Station" (PMS-008); (5) "Materials Processing in…

  14. 33 CFR 20.901 - Summary decisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Summary decisions. 20.901 Section....901 Summary decisions. (a) Any party may move for a summary decision in all or any part of the... after service of a motion for summary decision, may serve opposing affidavits or countermove for summary...

  15. High-efficiency headspace sampling of volatile organic compounds in explosives using capillary microextraction of volatiles (CMV) coupled to gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Fan, Wen; Almirall, José

    2014-03-01

    A novel geometry configuration based on sorbent-coated glass microfibers packed within a glass capillary is used to sample volatile organic compounds, dynamically, in the headspace of an open system or in a partially open system to achieve quantitative extraction of the available volatiles of explosives with negligible breakthrough. Air is sampled through the newly developed sorbent-packed 2 cm long, 2 mm diameter capillary microextraction of volatiles (CMV) and subsequently introduced into a commercially available thermal desorption probe fitted directly into a GC injection port. A sorbent coating surface area of ∼5 × 10(-2) m(2) or 5,000 times greater than that of a single solid-phase microextraction (SPME) fiber allows for fast (30 s), flow-through sampling of relatively large volumes using sampling flow rates of ∼1.5 L/min. A direct comparison of the new CMV extraction to a static (equilibrium) SPME extraction of the same headspace sample yields a 30 times improvement in sensitivity for the CMV when sampling nitroglycerine (NG), 2,4-dinitrotoluene (2,4-DNT), and diphenylamine (DPA) in a mixture containing a total mass of 500 ng of each analyte, when spiked into a liter-volume container. Calibration curves were established for all compounds studied, and the recovery was determined to be ∼1 % or better after only 1 min of sampling time. Quantitative analysis is also possible using this extraction technique when the sampling temperature, flow rate, and time are kept constant between calibration curves and the sample.

  16. Evaluation of a headspace solid-phase microextraction method for the analysis of ignitable liquids in fire debris.

    PubMed

    Fettig, Ina; Krüger, Simone; Deubel, Jan H; Werrel, Martin; Raspe, Tina; Piechotta, Christian

    2014-05-01

    The chemical analysis of fire debris represents a crucial part in fire investigations to determine the cause of a fire. A headspace solid-phase microextraction (HS-SPME) procedure for the detection of ignitable liquids in fire debris using a fiber coated with a mixture of three different sorbent materials (Divinylbenzene/Carboxen/Polydimethylsiloxane, DVB/CAR/PDMS) is described. Gasoline and diesel fuel were spiked upon a preburnt matrix (wood charcoal), extracted and concentrated with HS-SPME and then analyzed with gas chromatography/mass spectrometry (GC/MS). The experimental conditions--extraction temperature, incubation and exposure time--were optimized. To assess the applicability of the method, fire debris samples were prepared in the smoke density chamber (SDC) and a controlled-atmosphere cone calorimeter. The developed methods were successfully applied to burnt particleboard and carpet samples. The results demonstrate that the procedure that has been developed here is suitable for detecting these ignitable liquids in highly burnt debris. © 2013 American Academy of Forensic Sciences.

  17. Comparison of two headspace sampling techniques for the analysis of off-flavour volatiles from oat based products.

    PubMed

    Cognat, Claudine; Shepherd, Tom; Verrall, Susan R; Stewart, Derek

    2012-10-01

    Two different headspace sampling techniques were compared for analysis of aroma volatiles from freshly produced and aged plain oatcakes. Solid phase microextraction (SPME) using a Carboxen-Polydimethylsiloxane (PDMS) fibre and entrainment on Tenax TA within an adsorbent tube were used for collection of volatiles. The effects of variation in the sampling method were also considered using SPME. The data obtained using both techniques were processed by multivariate statistical analysis (PCA). Both techniques showed similar capacities to discriminate between the samples at different ages. Discrimination between fresh and rancid samples could be made on the basis of changes in the relative abundances of 14-15 of the constituents in the volatile profiles. A significant effect on the detection level of volatile compounds was observed when samples were crushed and analysed by SPME-GC-MS, in comparison to undisturbed product. The applicability and cost effectiveness of both methods were considered. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Development and validation of a fast static headspace GC method for determination of residual solvents in permethrin.

    PubMed

    Tian, Jingzhi; Rustum, Abu

    2016-09-05

    A fast static headspace gas chromatography (HS-GC) method was developed to separate all residual solvents present in commercial active pharmaceutical ingredient (API) batches of permethrin. A total of six residual solvents namely 2-methylpentane, 3-methylpentane, methylcyclopentane, n-hexane, cyclohexane and toluene were found in typical commercial batches of permethrin; and three of them are not in the list of ICH solvents. All six residual solvents were baseline separated in five minutes by the new method presented in this paper. The method was successfully validated as per International Conference on Harmonisation (ICH) guidelines. Evaluation of this method was conducted to separate 26 commonly used solvents in the manufacturing of various APIs, key intermediates of APIs and pharmaceutical excipients. The results of the evaluation demonstrated that this method can also be used as a general method to determine residual solvents in various APIs, intermediates and excipients that are used in pharmaceutical products. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. NFSMI Research Summary

    ERIC Educational Resources Information Center

    Nettles, Mary Frances

    2014-01-01

    The NFSMI Research Summary is a continuing series of summaries reporting recently completed research and research-based resources funded by the National Food Service Management Institute. The following research studies are summarized in this article: (1) Succession Planning for Management Level Staff in School Nutrition Programs; (2)…

  20. Optimization of a multiple headspace sorptive extraction method coupled to gas chromatography-mass spectrometry for the determination of volatile compounds in macroalgae.

    PubMed

    Maruti, Astrid; Durán-Guerrero, Enrique; Barroso, Carmelo G; Castro, Remedios

    2018-05-25

    A novel extraction technique is proposed in which the Multiple Headspace Extraction (MHE) approach is used in conjunction with Headspace Sorptive Extraction (HSSE) and Gas Chromatography-Mass Spectrometry (GC-MS) detection. The extraction method was developed to determine volatile compounds in macroalgae. Optimization of the extraction parameters was carried out using design of experiments to identify factors that affect the extraction: extraction time, temperature, twister length and amount of sample. The results of the optimization led to an extraction of 2 g of sample using a 20 mm Twister ® at 66 °C for 180 min. The progression constants (β) were calculated for 43 volatile compounds, 29 of which could be quantified using the method. Linearity was attained with a determination coefficient higher than 0.99 for all studied compounds. Inter-day and inter-twister precisions ranged from 0.22% to 19.01% and from 0.69% to 14.76% respectively, and values below 10% were obtained for the majority of compounds. LOD and LOQ values ranged from the values obtained for diethyl succinate (0.012 μg/L and 0.088 μg/L, respectively) and those obtained for dimethyl sulfide (5.544 μg/L and 40.286 μg/L, respectively). However, for the majority of compounds values obtained were below 1 μg/L (LOD) and 5 μg/L (LOQ). Compounds such as ethyl acetate, hexanal, heptadecane, 2-hexenal, 6-methyl-5-hepten-2-one, dimethyl sulfide, benzyl alcohol, beta ionone, or beta cyclocitral, among others were correctly determined in three species of macroalgae: Ulva sp., Gracillaria sp. and Enteromorpha sp. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Summary Writing: A Topographical Study.

    ERIC Educational Resources Information Center

    Sherrard, Carol

    1986-01-01

    Examines summaries of expository text written by undergraduate students to discover the nature of text-to-summary mapping. Finds that simple omission and one-to-one mapping of text sentences into summary sentences were the most favored strategies. (FL)

  2. Analysis of residual monomers in dendritic methacrylate copolymers and composites by HPLC and headspace-GC/MS.

    PubMed

    Viljanen, Eeva K; Langer, Sarka; Skrifvars, Mikael; Vallittu, Pekka K

    2006-09-01

    The aim of this study was to analyze the residual monomer content of photopolymerized dendritic methacrylate copolymers and particulate filler composites. Headspace-gas chromatography/mass spectrometry (HS-GC/MS) was compared with high performance liquid chromatography (HPLC). The resin mixtures consisted of a dendritic methacrylate monomer, methyl methacrylate and acetoacetoxyethyl methacrylate in varied proportions. In addition, one of the composites contained 1,4-butanediol dimethacrylate. Camphorquinone and 2-(N,N-dimethylamino)ethyl methacrylate were used as the light-activated initiator system. The content of residual methyl methacrylate and acetoacetoxyethyl methacrylate after 40 s photopolymerization were analyzed with HPLC and HS-GC/MS. The content of residual methyl methacrylate decreased and residual acetoacetoxyethyl methacrylate increased with increasing concentration of acetoacetoxyethyl methacrylate in the resin mixture. The results with both methods had the same trend. The addition of acetoacetoxyethyl methacrylate enhanced the copolymerization of methyl methacrylate, but did not decrease the total residual monomer content. The HS-GC/MS method was found to be a feasible method in the analysis of low-boiling residuals in dental polymers.

  3. Trace-level screening of dichlorophenols in processed dairy milk by headspace gas chromatography.

    PubMed

    Gras, Kaelyn; Luong, Jim; Gras, Ronda; Shellie, Robert A

    2016-10-01

    A headspace gas chromatographic approach based on flame ionization detection has been successfully developed for the determination of parts-per-billion levels of 2,4-dichlorophenol and 2,6-dichlorophenol in processed dairy milk. Under the right environmental conditions, these compounds are produced as products of the reductive dechlorination of pentachlorophenol. Maintaining a highly inert chromatographic system and employing a recently commercialized inert capillary column permits the analysis of 2,4-dichlorophenol and 2,6-dichlorophenol without derivatization. Further, a detection limit improvement of more than a factor of two was achieved by adding sodium sulfate to substantially decrease the solute partition coefficient in the matrix. A detection limit of 1 ng/g and a limit of quantitation of 2 ng/g were attained, and complete analysis can be conducted in < 13 min. Reproducibility of area counts over a range from 20 to 200 ng/g and over a period of 2 days were found to be less than 6% (n = 20). A linear range from 5 to 500 ng/g with a correlation coefficient of at least 0.9992 was obtained for 2,4-dichlorophenol and 2,6-dichlorophenol. Spike recoveries from 10 to 500 ng/g for all the analytes range from 92 to 102%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. 15 CFR 904.210 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Summary decision. 904.210 Section 904... Hearing and Appeal Procedures General § 904.210 Summary decision. The Judge may render a summary decision... summary decision as a matter of law. ...

  5. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  6. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance: Treasury 1 2012-07-01 2012-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  7. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 1 2014-07-01 2014-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  8. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance: Treasury 1 2011-07-01 2011-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  9. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance: Treasury 1 2013-07-01 2013-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  10. 40 CFR 1502.12 - Summary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Summary. 1502.12 Section 1502.12 Protection of Environment COUNCIL ON ENVIRONMENTAL QUALITY ENVIRONMENTAL IMPACT STATEMENT § 1502.12 Summary. Each environmental impact statement shall contain a summary which adequately and accurately summarizes...

  11. 17 CFR 12.207 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Summary disposition. 12.207... REPARATIONS Rules Applicable to Summary Decisional Proceedings § 12.207 Summary disposition. (a) Filing of... proceeding may file a motion for summary disposition at any time until the parties have concluded their...

  12. 49 CFR 194.113 - Information summary.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Information summary. 194.113 Section 194.113... Response Plans § 194.113 Information summary. (a) The information summary for the core plan, required by... state(s). (b) The information summary for the response zone appendix, required in § 194.107, must...

  13. Determination of N,N-dimethyltryptamine in beverages consumed in religious practices by headspace solid-phase microextraction followed by gas chromatography ion trap mass spectrometry.

    PubMed

    Gaujac, Alain; Dempster, Nicola; Navickiene, Sandro; Brandt, Simon D; de Andrade, Jailson Bittencourt

    2013-03-15

    A novel analytical approach combining solid-phase microextraction (SPME)/gas chromatography ion trap mass spectrometry (GC-IT-MS) was developed for the detection and quantification N,N-dimethyltryptamine (DMT), a powerful psychoactive indole alkaloid present in a variety of South American indigenous beverages, such as ayahuasca and vinho da jurema. These particular plant products, often used within a religious context, are increasingly consumed throughout the world following an expansion of religious groups and the availability of plant material over the Internet and high street shops. The method described in the present study included the use of SPME in headspace mode combined GC-IT-MS and included the optimization of the SPME procedure using multivariate techniques. The method was performed with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in headspace mode (70 min at 60 °C) which resulted in good precision (RSD<8.6%) and accuracy values (71-109%). Detection and quantification limits obtained for DMT were 0.78 and 9.5 mg L(-1), respectively and good linearity (1.56-300 mg L(-1), r(2)=0.9975) was also observed. In addition, the proposed method showed good robustness and allowed for the minimization of sample manipulation. Five jurema beverage samples were prepared in the laboratory in order to study the impact of temperature, pH and ethanol on the ability to extract DMT into solution. The developed method was then applied to the analysis of twelve real ayahuasca and vinho da jurema samples, obtained from Brazilian religious groups, which revealed DMT concentration levels between 0.10 and 1.81 g L(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Determination of roasted pistachio (Pistacia vera L.) key odorants by headspace solid-phase microextraction and gas chromatography-olfactometry.

    PubMed

    Aceña, Laura; Vera, Luciano; Guasch, Josep; Busto, Olga; Mestres, Montserrat

    2011-03-23

    Key odorants in roasted pistachio nuts have been determined for the first time. Two different pistachio varieties (Fandooghi and Kerman) have been analyzed by means of headspace solid-phase microextraction (HS-SPME) and gas chromatography-olfactometry (GCO). The aroma extract dilution analyses (AEDA) applied have revealed 46 and 41 odor-active regions with a flavor dilution (FD) factor≥64 for the Fandooghi and the Kerman varieties, respectively, and 39 of them were related to precisely identified compounds. These included esters, pyrazines, aldehydes, acids, furans, and phenols. The results show that the Fandooghi variety presents, not only more odor-active regions but also higher FD factors than the Kerman variety that can lead to the conclusion that the first variety has a richer aromatic profile than the second one. The descriptive sensory analysis (DSA) showed that the roasted, chocolate/coffee, and nutty attributes were rated significantly higher in the Fandooghi variety, whereas the green attribute was significantly higher in the Kerman one.

  15. 13 CFR 134.408 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Summary decision. 134.408 Section... § 134.408 Summary decision. (a) Generally. In any appeal under this subpart D, either party may move or cross-move for summary decision, as provided in § 134.212. (b) Summary decision based on fewer than all...

  16. Summary travel characteristics : Hawaii

    DOT National Transportation Integrated Search

    1997-10-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  17. Summary travel characteristics : Massachusetts

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  18. Summary travel characteristics : Arkansas

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  19. Summary travel characteristics : Virgina

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  20. Summary travel characteristics : Florida

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  1. Summary travel characteristics : Kansas

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  2. Summary travel characteristics : California

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  3. Summary travel characteristics : Texas

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  4. Summary travel characteristics : Illinois

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  5. Summary travel characteristics : Montana

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  6. Summary travel characteristics : Kentucky

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  7. Summary travel characteristics : Wisconsin

    DOT National Transportation Integrated Search

    1997-10-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  8. Summary travel characteristics : Maryland

    DOT National Transportation Integrated Search

    1997-09-19

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  9. Summary travel characteristics : Nevada

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  10. Summary travel characteristics : Iowa

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  11. Summary travel characteristics : Washington

    DOT National Transportation Integrated Search

    1997-10-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  12. Summary travel characteristics : Alabama

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  13. Summary travel characteristics : Nebraska

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  14. Summary travel characteristics : Oregon

    DOT National Transportation Integrated Search

    1997-10-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  15. Summary travel characteristics : Maine

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  16. Summary travel characteristics : Utah

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  17. Summary travel characteristics : Michigan

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  18. Summary travel characteristics : Missouri

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  19. Summary travel characteristics : Colorado

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  20. Summary travel characteristics : Alaska

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  1. Summary travel characteristics : Oklahoma

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  2. Summary travel characteristics : Indiana

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  3. Summary travel characteristics : Idaho

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  4. Summary travel characteristics : Tennessee

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  5. Summary travel characteristics : Georgia

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  6. Summary travel characteristics : Delaware

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  7. Summary travel characteristics : Ohio

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  8. Summary travel characteristics : Arizona

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  9. Summary travel characteristics : Wyoming

    DOT National Transportation Integrated Search

    1997-01-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  10. Summary travel characteristics : Minnesota

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  11. Summary travel characteristics : Vermont

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  12. Summary travel characteristics : Louisiana

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  13. Summary travel characteristics : Mississippi

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  14. Summary travel characteristics : Connecticut

    DOT National Transportation Integrated Search

    1997-09-29

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  15. Summary travel characteristics : Pennsylvania

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  16. 29 CFR 18.1006 - Summaries.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Summaries. 18.1006 Section 18.1006 Labor Office of the... ADMINISTRATIVE LAW JUDGES Rules of Evidence Contents of Writings, Recordings, and Photographs § 18.1006 Summaries... at the hearing may be presented in the form of a chart, summary, or calculation. The originals, or...

  17. Characterization of Laboratory Prepared Concrete Pastes Exposed to High Alkaline and High Sodium Salt Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langton, C. A.

    The objective of this study was to identify potential chemical degradation mechanisms for the Saltstone Disposal Unit (SDU) concretes, which over the performance life of the structures may be exposed to highly alkaline sodium salt solutions containing sulfate, hydroxide, and other potentially corrosive chemicals in salt solution and saltstone flush water, drain water, leachate and / or pore solution. The samples analyzed in this study were cement pastes prepared in the SIMCO Technologies, Inc. concrete laboratory. They were based on the paste fractions of the concretes used to construct the Saltstone Disposal Units (SDUs). SDU 1 and 4 concrete pastesmore » were represented by the PV1 test specimens. The paste in the SDU 2, 3, 5, and 6 concrete was represented by the PV2 test specimens. SIMCO Technologies, Inc. selected the chemicals and proportions in the aggressive solutions to approximate proportions in the saltstone pore solution [2, 3, 5, and 6]. These test specimens were cured for 56 days in curing chamber before being immersed in aggressive solutions. After exposure, the samples were frozen to prevent additional chemical transport and reaction. Selected archived (retrieved from the freezer) samples were sent to the Savannah River National Laboratory (SRNL) for additional characterization using x-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive x-ray (EDX) spectroscopy. Characterization results are summarized in this report. In addition, a correlation between the oxide composition of the pastes and their chemical durability in the alkaline salt solutions is provided.« less

  18. 19 CFR 142.16 - Entry summary documentation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Entry summary documentation. 142.16 Section 142.16... TREASURY (CONTINUED) ENTRY PROCESS Entry Summary Documentation § 142.16 Entry summary documentation. (a) Entry summary not filed at time of entry. When the entry documentation is filed before the entry summary...

  19. Determination of Odor Release in Hydrocolloid Model Systems Containing Original or Carboxylated Cellulose at Different pH Values Using Static Headspace Gas Chromatographic (SHS-GC) Analysis

    PubMed Central

    Lee, Sang Mi; Shin, Gil-Ok; Park, Kyung Min; Chang, Pahn-Shick; Kim, Young-Suk

    2013-01-01

    Static headspace gas chromatographic (SHS-GC) analysis was performed to determine the release of 13 odorants in hydrocolloid model systems containing original or regio-selectively carboxylated cellulose at different pH values. The release of most odor compounds was decreased in the hydrocolloid solutions compared to control, with the amounts of 2-propanol, 3-methyl-1-butanol, and 2,3-butanedione released into the headspace being less than those of any other odor compound in the hydrocolloid model systems. However, there was no considerable difference between original cellulose-containing and carboxylated-cellulose containing systems in the release of most compounds, except for relatively long-chain esters such as ethyl caprylate and ethyl nonanoate. The release from the original and carboxylated cellulose solutions controlled to pH 10 was significantly higher than that from solutions adjusted to pH 4 and 7 in the case of some esters (ethyl acetate, methyl propionate, ethyl propionate, ethyl butyrate, butyl propionate, ethyl caproate) and alcohols (2-propanol, 3-methyl-1-butanol), in particular, ethyl butyrate and 3-methyl-1-butanol. In contrast, the release of 2,3-butanedione from both the original and carboxylated cellulose solutions was increased at pH 4 and 7 compared to that at pH 10 by about 70% and 130%, respectively. Our study demonstrated that the release of some odorants could be changed significantly by addition of both original and carboxylated cellulose in hydrocolloid model systems, but only minor effect was observed in pH of the solution. PMID:23447013

  20. [A novel vapor dynamic headspace enrichment equipment for nontarget screening of volatile organic compounds in drinking water].

    PubMed

    Ma, Huilian; Zhang, Haijun; Tian, Yuzeng; Wang, Longxing; Chen, Jiping

    2011-09-01

    A novel vapor dynamic headspace enrichment device was set up for nontarget screening of volatile organic compounds (VOCs) in drinking water. The main operating parameters of this device, such as length of distillation tube, volume of collected condensate, and choice of absorbent, were optimized. In this device, vapor was utilized as a purge gas and water was utilized as a absorbent. With the help of the device, one liter of water sample could be concentrated to 5 mL and the sensitivity of traditional purge and trap-gas chromatography-mass spectrometry (P&T-GC-MS) could be improved 1-2 orders of magnitude. Source and disinfected water samples from a water treatment plant were analyzed with this method. Compared with the traditional P&T-GC-MS analysis without pre-enrichment, the numbers of identified VOCs were improved from 0 to 16 for source water and 5 to 35 for disinfected water samples. It is also shown that there are many halide compounds in VOCs in disinfected water which do not exist in source water.

  1. 49 CFR 194.113 - Information summary.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Response Plans § 194.113 Information summary. (a) The information summary for the core plan, required by... include: (1) The information summary for the core plan; (2) The names or titles and 24-hour telephone...

  2. Identification and quantification of ethylene oxide in sterilized medical devices using multiple headspace GC/MS measurement.

    PubMed

    Gimeno, Pascal; Auguste, Marie-Laure; Handlos, Vagn; Nielsen, Anne Mette; Schmidt, Stephan; Lassu, Nelly; Vogel, Martin; Fischer, Antonius; Brenier, Charlotte; Duperray, Françoise

    2018-05-22

    This manuscript, based on the ISO 10993-7 approach, describes a multiple HS-GC measurement of residual EO present in sterilized plastic samples. The quantification of EO is done, according to the ISO standard, by addition of EO amounts extracted for each repeated extraction. During the method development, the specificity of the detection of EO regarding acetaldehyde (structural isomer of EO) which may be formed from EO has been ensured and different tests were performed to check a possible influence of the sample preparation. Assays to maximize EO extraction were performed for different materials (Cyclo-olefine Copolymer (COC), Cyclo-olefine Polymer (COP), Silicon, Polyurethane (PUR)) changing extraction temperatures and times for the headspace and the pre-thermal treatment. Results highlight that depending on the material, EO can be more or less retained and thus thermal extraction conditions to maximize the amount of extractible EO from plastics may change accordingly. For COC syringes a validation according to ICH guidelines and an inter-laboratories study were performed. The method has been used for a market survey of EO sterilized medical devices, results obtained are reported in this manuscript. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Ultrasensitive Speciation Analysis of Mercury in Rice by Headspace Solid Phase Microextraction Using Porous Carbons and Gas Chromatography-Dielectric Barrier Discharge Optical Emission Spectrometry.

    PubMed

    Lin, Yao; Yang, Yuan; Li, Yuxuan; Yang, Lu; Hou, Xiandeng; Feng, Xinbin; Zheng, Chengbin

    2016-03-01

    Rice consumption is a primary pathway for human methylmercury (MeHg) exposure in inland mercury mining areas of Asia. In addition, the use of iodomethane, a common fumigant that significantly accelerates the methylation of mercury in soil under sunlight, could increase the MeHg exposure from rice. Conventional hyphenated techniques used for mercury speciation analysis are usually too costly for most developing countries. Consequently, there is an increased interest in the development of sensitive and inexpensive methods for the speciation of mercury in rice. In this work, gas chromatography (GC) coupled to dielectric barrier discharge optical emission spectrometry (DBD-OES) was developed for the speciation analysis of mercury in rice. Prior to GC-DBD-OES analysis, mercury species were derivatized to their volatile species with NaBPh4 and preconcentrated by headspace solid phase microextraction using porous carbons. Limits of detection of 0.5 μg kg(-1) (0.16 ng), 0.75 μg kg(-1) (0.24 ng), and 1.0 μg kg(-1) (0.34 ng) were obtained for Hg(2+), CH3Hg(+), and CH3CH2Hg(+), respectively, with relative standard deviations (RSDs) better than 5.2% and 6.8% for one fiber or fiber-to-fiber mode, respectively. Recoveries of 90-105% were obtained for the rice samples, demonstrating the applicability of the proposed technique. Owing to the small size, low power, and low gas consumption of DBD-OES as well as efficient extraction of mercury species by porous carbons headspace solid phase micro-extraction, the proposed technique provides several advantages including compactness, cost-effectiveness, and potential to couple with miniature GC to accomplish the field speciation of mercury in rice compared to conventional hyphenated techniques.

  4. Analysis of potassium formate in airport storm water runoff by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

    PubMed

    Fries, Elke; Klasmeier, Jörg

    2009-01-30

    Potassium formate was extracted from airport storm water runoff by headspace solid-phase microextraction (HS-SPME) and analyzed by GC-MS. Formate was transformed to formic acid by adding phosphoric acid. Subsequently, formic acid was derivatized to methyl formate by adding methanol. Using sodium [(2)H]formate (formate-d) as an internal standard, the relative standard deviation of the peak area ratio of formate (m/z 60) and formate-d (m/z 61) was 0.6% at a concentration of 208.5 mg L(-1). Calibration was linear in the range of 0.5-208.5 mg L(-1). The detection limit calculated considering the blank value was 0.176 mg L(-1). The mean concentration of potassium formate in airport storm water runoff collected after surface de-icing operations was 86.9 mg L(-1) (n=11) with concentrations ranging from 15.1 mg L(-1) to 228.6 mg L(-1).

  5. Determination of epichlorohydrin and 1,3-dichloro-2-propanol in synthesis of cationic etherifying reagent by headspace gas chromatography.

    PubMed

    Tao, Zheng-Yi; Chai, Xin-Sheng; Wu, Shu-Bin

    2011-09-16

    This study demonstrates a headspace gas chromatographic(HS-GC) technique for the determination of residual epichlorohydrin (ECH) and generated 1,3-dichloro-2-propanol (DCP) in synthesis process of 3-chloro-2-hydroxypropyltrimethylammonium chloride (CHTAC). By a weight-based sampling method, coupled with significant dilution in 15.8% sodium sulfate and 0.1% silver nitrate mixed solution rapidly, the sample for HS-GC analysis is prepared. Based on the reaction stoichiometry, the conversion (R) of CHTAC during the synthesis process can be calculated from sampling weight and GC peak area. The results showed that the method has a good measurement precision (RSD<2.5%) and accuracy (recovery=101-104%) for the quantification of both ECH and DCP in the process samples. The present method is simple and accurate, which can be used for the efficient determination of the CHTAC conversion in the synthesis research. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. 19 CFR 210.18 - Summary determinations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 3 2010-04-01 2010-04-01 false Summary determinations. 210.18 Section 210.18 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Motions § 210.18 Summary determinations. (a) Motions for summary...

  7. 19 CFR 210.18 - Summary determinations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 3 2011-04-01 2011-04-01 false Summary determinations. 210.18 Section 210.18 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Motions § 210.18 Summary determinations. (a) Motions for summary...

  8. 19 CFR 210.18 - Summary determinations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 3 2013-04-01 2013-04-01 false Summary determinations. 210.18 Section 210.18 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Motions § 210.18 Summary determinations. (a) Motions for summary...

  9. 19 CFR 210.18 - Summary determinations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 3 2014-04-01 2014-04-01 false Summary determinations. 210.18 Section 210.18 Customs Duties UNITED STATES INTERNATIONAL TRADE COMMISSION INVESTIGATIONS OF UNFAIR PRACTICES IN IMPORT TRADE ADJUDICATION AND ENFORCEMENT Motions § 210.18 Summary determinations. (a) Motions for summary...

  10. 78 FR 11216 - Enforcement Actions Summary

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-15

    ...] Enforcement Actions Summary AGENCY: Transportation Security Administration, DHS. ACTION: Notice of... an annual summary of all enforcement actions taken by TSA under the authority granted in the... public with an annual summary of all enforcement actions taken by TSA under this subsection; and include...

  11. 77 FR 12865 - Enforcement Actions Summary

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-02

    ...] Enforcement Actions Summary AGENCY: Transportation Security Administration, DHS. ACTION: Notice of... an annual summary of all enforcement actions taken by TSA under the authority granted in the... public with an annual summary of all enforcement actions taken by TSA under this subsection; and include...

  12. 76 FR 9357 - Enforcement Actions Summary

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-17

    ...] Enforcement Actions Summary AGENCY: Transportation Security Administration, DHS. ACTION: Notice of... an annual summary of all enforcement actions taken by TSA under the authority granted in the... to provide the public with an annual summary of all enforcement actions taken by TSA under this...

  13. 16 CFR 3.24 - Summary decisions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Summary decisions. 3.24 Section 3.24... PRACTICE FOR ADJUDICATIVE PROCEEDINGS Prehearing Procedures; Motions; Interlocutory Appeals; Summary Decisions § 3.24 Summary decisions. (a) Procedure. (1) Any party may move, with or without supporting...

  14. 19 CFR 191.73 - Export summary procedure.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Export summary procedure. 191.73 Section 191.73... TREASURY (CONTINUED) DRAWBACK Exportation and Destruction § 191.73 Export summary procedure. (a) General. The export summary procedure consists of a Chronological Summary of Exports used to support a drawback...

  15. 12 CFR 908.52 - Partial summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Partial summary disposition. 908.52 Section 908... summary disposition. If the presiding officer determines that a party is entitled to summary disposition... presiding officer has determined that summary disposition is warranted will be addressed in the recommended...

  16. 7 CFR 3402.12 - Project summary.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 15 2012-01-01 2012-01-01 false Project summary. 3402.12 Section 3402.12 Agriculture... AGRICULTURAL SCIENCES NATIONAL NEEDS GRADUATE AND POSTGRADUATE FELLOWSHIP GRANTS PROGRAM Preparation of an Application § 3402.12 Project summary. Using the Project Summary, Form NIFA-2003, applicants must summarize...

  17. 7 CFR 3402.12 - Project summary.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Project summary. 3402.12 Section 3402.12 Agriculture... AGRICULTURAL SCIENCES NATIONAL NEEDS GRADUATE AND POSTGRADUATE FELLOWSHIP GRANTS PROGRAM Preparation of an Application § 3402.12 Project summary. Using the Project Summary, Form NIFA-2003, applicants must summarize...

  18. 7 CFR 3402.12 - Project summary.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 15 2013-01-01 2013-01-01 false Project summary. 3402.12 Section 3402.12 Agriculture... AGRICULTURAL SCIENCES NATIONAL NEEDS GRADUATE AND POSTGRADUATE FELLOWSHIP GRANTS PROGRAM Preparation of an Application § 3402.12 Project summary. Using the Project Summary, Form NIFA-2003, applicants must summarize...

  19. 7 CFR 3402.12 - Project summary.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 15 2011-01-01 2011-01-01 false Project summary. 3402.12 Section 3402.12 Agriculture... AGRICULTURAL SCIENCES NATIONAL NEEDS GRADUATE AND POSTGRADUATE FELLOWSHIP GRANTS PROGRAM Preparation of an Application § 3402.12 Project summary. Using the Project Summary, Form CSREES-2003, applicants must summarize...

  20. 7 CFR 3402.12 - Project summary.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Project summary. 3402.12 Section 3402.12 Agriculture Regulations of the Department of Agriculture (Continued) COOPERATIVE STATE RESEARCH, EDUCATION, AND EXTENSION... FELLOWSHIP GRANTS PROGRAM Preparation of an Application § 3402.12 Project summary. Using the Project Summary...

  1. 12 CFR 509.29 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Summary disposition. 509.29 Section 509.29... PROCEDURE IN ADJUDICATORY PROCEEDINGS Uniform Rules of Practice and Procedure § 509.29 Summary disposition... granting a motion for summary disposition if the undisputed pleaded facts, admissions, affidavits...

  2. 5 CFR 2423.27 - Summary judgment motions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Summary judgment motions. 2423.27 Section..., Prehearing Procedures § 2423.27 Summary judgment motions. (a) Motions. Any party may move for a summary... to be determined at the hearing. (c) Decision. If all issues are decided by summary judgment, no...

  3. Determination of volatile monophenols in beer using acetylation and headspace solid-phase microextraction in combination with gas chromatography and mass spectrometry.

    PubMed

    Sterckx, Femke L; Saison, Daan; Delvaux, Freddy R

    2010-08-31

    Monophenols are widely spread compounds contributing to the flavour of many foods and beverages. They are most likely present in beer, but so far, little is known about their influence on beer flavour. To quantify these monophenols in beer, we optimised a headspace solid-phase microextraction method coupled to gas chromatography-mass spectrometry. To improve their isolation from the beer matrix and their chromatographic properties, the monophenols were acetylated using acetic anhydride and KHCO(3) as derivatising agent and base catalyst, respectively. Derivatisation conditions were optimised with attention for the pH of the reaction medium. Additionally, different parameters affecting extraction efficiency were optimised, including fibre coating, extraction time and temperature and salt addition. Afterwards, we calibrated and validated the method successfully and applied it for the analysis of monophenols in beer samples. 2010 Elsevier B.V. All rights reserved.

  4. Use of headspace sorptive extraction coupled to gas chromatography-mass spectrometry for the analysis of volatile polycyclic aromatic hydrocarbons in herbal infusions.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2014-08-22

    A solvent-free method is described for the determination of 10 volatile polycyclic aromatic hydrocarbons (PAHs), considered as priority pollutants by the EU, in different herbal infusions using headspace sorptive extraction (HSSE) and gas chromatography-mass spectrometry (GC-MS). The parameters affecting both the extraction and thermal desorption steps in the HSSE were optimized by means of Plackett-Burman designs. Ten millilitres of the herbal infusion was submitted to the HSSE preconcentration in the presence of salt for 4h at 88 °C. The use of d(10)-phenanthrene as internal standard not only improved the repeatability of the method but allowed quantification of the samples against external aqueous standards. Detection limits ranged between 11 and 26 ng L(-1). Copyright © 2014 Elsevier B.V. All rights reserved.

  5. 12 CFR 263.29 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Summary disposition. 263.29 Section 263.29... RULES OF PRACTICE FOR HEARINGS Uniform Rules of Practice and Procedure § 263.29 Summary disposition. (a... a motion for summary disposition if the undisputed pleaded facts, admissions, affidavits...

  6. 10 CFR 2.1205 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Summary disposition. 2.1205 Section 2.1205 Energy NUCLEAR... Hearing Procedures for NRC Adjudications § 2.1205 Summary disposition. (a) Unless the presiding officer or the Commission directs otherwise, motions for summary disposition may be submitted to the presiding...

  7. 16 CFR 1502.31 - Summary decisions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Summary decisions. 1502.31 Section 1502.31... PROCEDURES FOR FORMAL EVIDENTIARY PUBLIC HEARING Hearing Procedures § 1502.31 Summary decisions. (a) After the hearing commences, a participant may move, with or without supporting affidavits, for a summary...

  8. 12 CFR 1780.31 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Summary disposition. 1780.31 Section 1780.31... Summary disposition. (a) In general. The presiding officer shall recommend that the Director issue a final order granting a motion for summary disposition if the undisputed pleaded facts, admissions, affidavits...

  9. 12 CFR 308.29 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Summary disposition. 308.29 Section 308.29... PRACTICE AND PROCEDURE Uniform Rules of Practice and Procedure § 308.29 Summary disposition. (a) In general... a motion for summary disposition if the undisputed pleaded facts, admissions, affidavits...

  10. 29 CFR 1955.22 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Summary decision. 1955.22 Section 1955.22 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) PROCEDURES FOR WITHDRAWAL OF APPROVAL OF STATE PLANS Consent Findings and Summary Decisions § 1955.22 Summary...

  11. Does Writing Summaries Improve Memory for Text?

    ERIC Educational Resources Information Center

    Spirgel, Arie S.; Delaney, Peter F.

    2016-01-01

    In five experiments, we consistently found that items included in summaries were better remembered than items omitted from summaries. We did not, however, find evidence that summary writing was better than merely restudying the text. These patterns held with shorter and longer texts, when the text was present or absent during the summary writing,…

  12. 19 CFR 142.11 - Entry summary form.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Entry summary form. 142.11 Section 142.11 Customs... (CONTINUED) ENTRY PROCESS Entry Summary Documentation § 142.11 Entry summary form. (a) Customs Form 7501. The entry summary shall be on Customs Form 7501 unless a different form is prescribed elsewhere in this...

  13. 17 CFR 12.310 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Summary disposition. 12.310... REPARATIONS Rules Applicable to Formal Decisional Proceedings § 12.310 Summary disposition. (a) Filing of... proceeding may file a motion for summary disposition at any time before a determination is made by the...

  14. 29 CFR 1905.41 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Summary decision. 1905.41 Section 1905.41 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR RULES OF... OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 Summary Decisions § 1905.41 Summary decision. (a) No genuine issue...

  15. 40 CFR 179.90 - Summary decisions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Summary decisions. 179.90 Section 179... EVIDENTIARY PUBLIC HEARING Hearing Procedures § 179.90 Summary decisions. (a) After the hearing commences, a party may file a written motion, with or without supporting affidavits or brief, for a summary decision...

  16. 12 CFR 908.51 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Summary disposition. 908.51 Section 908.51... OPERATIONS RULES OF PRACTICE AND PROCEDURE IN HEARINGS ON THE RECORD Pre-Hearing Proceedings § 908.51 Summary... order granting a motion for summary disposition if the undisputed pleaded facts, admissions, affidavits...

  17. Computerized summary scoring: crowdsourcing-based latent semantic analysis.

    PubMed

    Li, Haiying; Cai, Zhiqiang; Graesser, Arthur C

    2017-11-03

    In this study we developed and evaluated a crowdsourcing-based latent semantic analysis (LSA) approach to computerized summary scoring (CSS). LSA is a frequently used mathematical component in CSS, where LSA similarity represents the extent to which the to-be-graded target summary is similar to a model summary or a set of exemplar summaries. Researchers have proposed different formulations of the model summary in previous studies, such as pregraded summaries, expert-generated summaries, or source texts. The former two methods, however, require substantial human time, effort, and costs in order to either grade or generate summaries. Using source texts does not require human effort, but it also does not predict human summary scores well. With human summary scores as the gold standard, in this study we evaluated the crowdsourcing LSA method by comparing it with seven other LSA methods that used sets of summaries from different sources (either experts or crowdsourced) of differing quality, along with source texts. Results showed that crowdsourcing LSA predicted human summary scores as well as expert-good and crowdsourcing-good summaries, and better than the other methods. A series of analyses with different numbers of crowdsourcing summaries demonstrated that the number (from 10 to 100) did not significantly affect performance. These findings imply that crowdsourcing LSA is a promising approach to CSS, because it saves human effort in generating the model summary while still yielding comparable performance. This approach to small-scale CSS provides a practical solution for instructors in courses, and also advances research on automated assessments in which student responses are expected to semantically converge on subject matter content.

  18. Simple determination of fluoride in biological samples by headspace solid-phase microextraction and gas chromatography-tandem mass spectrometry.

    PubMed

    Kwon, Sun-Myung; Shin, Ho-Sang

    2015-08-14

    A simple and convenient method to detect fluoride in biological samples was developed. This method was based on derivatization with 2-(bromomethyl)naphthalene, headspace solid phase microextraction (HS-SPME) in a vial, and gas chromatography-tandem mass spectrometric detection. The HS-SPME parameters were optimized as follows: selection of CAR/PDMS fiber, 0.5% 2-(bromomethyl)naphthalene, 250 mg/L 15-crown-5-ether as a phase transfer catalyst, extraction and derivatization temperature of 95 °C, heating time of 20 min and pH of 7.0. Under the established conditions, the lowest limits of detection were 9 and 11 μg/L in 1.0 ml of plasma and urine, respectively, and the intra- and inter-day relative standard deviation was less than 7.7% at concentrations of 0.1 and 1.0 mg/L. The calibration curve showed good linearity of plasma and urine with r=0.9990 and r=0.9992, respectively. This method is simple, amenable to automation and environmentally friendly. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. 30 CFR 44.41 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Summary decision. 44.41 Section 44.41 Mineral... REQUIREMENTS RULES OF PRACTICE FOR PETITIONS FOR MODIFICATION OF MANDATORY SAFETY STANDARDS Summary Decisions § 44.41 Summary decision. (a) No genuine issue of material fact. (1) Where no genuine issue of a...

  20. 43 CFR 4.1285 - Summary dismissal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Summary dismissal. 4.1285 Section 4.1285 Public Lands: Interior Office of the Secretary of the Interior DEPARTMENT HEARINGS AND APPEALS PROCEDURES... of the Office of Surface Mining § 4.1285 Summary dismissal. An appeal shall be subject to summary...

  1. 49 CFR 1150.44 - Caption summary.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Caption summary. 1150.44 Section 1150.44... Exempt Transactions Under 49 U.S.C. 10902 for Class III Rail Carriers § 1150.44 Caption summary. The caption summary must be in the following form. The information symbolized by numbers is identified in the...

  2. 21 CFR 12.93 - Summary decisions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Summary decisions. 12.93 Section 12.93 Food and... PUBLIC HEARING Hearing Procedures § 12.93 Summary decisions. (a) After the hearing commences, a participant may move, with or without supporting affidavits, for a summary decision on any issue in the...

  3. 12 CFR 747.29 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Summary disposition. 747.29 Section 747.29... of Practice and Procedure § 747.29 Summary disposition. (a) In general. The administrative law judge shall recommend that the NCUA Board issue a final order granting a motion for summary disposition if the...

  4. 12 CFR 19.29 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Summary disposition. 19.29 Section 19.29 Banks... Uniform Rules of Practice and Procedure § 19.29 Summary disposition. (a) In general. The administrative law judge shall recommend that the Comptroller issue a final order granting a motion for summary...

  5. 15 CFR 785.7 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Summary decision. 785.7 Section 785.7... INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE ADDITIONAL PROTOCOL REGULATIONS ENFORCEMENT § 785.7 Summary decision. The ALJ may render a summary decision disposing of all or part of a proceeding on the motion of...

  6. 43 CFR 4.1125 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Summary decision. 4.1125 Section 4.1125... Special Rules Applicable to Surface Coal Mining Hearings and Appeals Evidentiary Hearings § 4.1125 Summary decision. (a) At any time after a proceeding has begun, a party may move for summary decision of the whole...

  7. 15 CFR 280.209 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Summary decision. 280.209 Section 280... QUALITY Enforcement § 280.209 Summary decision. At any time after a proceeding has been initiated, a party may move for a summary decision disposing of some or all of the issues. The administrative law judge...

  8. 43 CFR 4.402 - Summary dismissal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Summary dismissal. 4.402 Section 4.402... Special Rules Applicable to Public Land Hearings and Appeals Appeals Procedures § 4.402 Summary dismissal. An appeal to the Board will be subject to summary dismissal by the Board for any of the following...

  9. Determination of ammonium in aqueous samples using new headspace dynamic in-syringe liquid-phase microextraction with in situ derivitazation coupled with liquid chromatography-fluorescence detection.

    PubMed

    Muniraj, Sarangapani; Yan, Cheing-Tong; Shih, Hou-Kung; Ponnusamy, Vinoth Kumar; Jen, Jen-Fon

    2012-11-19

    A new simultaneous derivatization and extraction method for the preconcentration of ammonia using new one-step headspace dynamic in-syringe liquid-phase microextraction with in situ derivatization was developed for the trace determination of ammonium in aqueous samples by liquid chromatography with fluorescence detection (LC-FLD). The acceptor phase (as derivatization reagent) containing o-phthaldehyde and sodium sulfite was held within a syringe barrel and immersed in the headspace of sample container. The gaseous ammonia from the alkalized aqueous sample formed a stable isoindole derivative with the acceptor phase inside the syringe barrel through the reciprocated movements of plunger. After derivatization-cum-extraction, the acceptor phase was directly injected into LC-FLD for analysis. Parameters affecting the ammonia evolution and the extraction/derivatization efficiency such as sample matrix, pH, temperature, sampling time, and the composition of derivatization reagent, reaction temperature, and frequency of reciprocated plunger, were studied thoroughly. Results indicated that the maximum extraction efficiency was obtained by using 100μL derivatization reagent in a 1-mL gastight syringe under 8 reciprocated movements of plunger per min to extract ammonia evolved from a 20mL alkalized aqueous solution at 70°C (preheated 4min) with 380rpm stirring for 8min. The detection was linear in the concentration range of 0.625-10μM with the correlation coefficient of 0.9967 and detection limit of 0.33μM (5.6ng mL(-1)) based on SN(-1)=3. The method was applied successfully to determine ammonium in real water samples without any prior cleanup of the samples, and has been proved to be a simple, sensitive, efficient and cost-effective procedure for trace ammonium determination in aqueous samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Summary travel characteristics : New Jersey

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  11. Summary travel characteristics : New Hampshire

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  12. Summary travel characteristics : New York

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  13. Summary travel characteristics : New Mexico

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  14. Summary travel characteristics : South Dakota

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  15. Summary travel characteristics : South Carolina

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  16. Summary travel characteristics : North Carolina

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  17. Summary travel characteristics : West Virginia

    DOT National Transportation Integrated Search

    1997-10-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  18. Summary travel characteristics : North Dakota

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  19. Summary travel characteristics : Rhode Island

    DOT National Transportation Integrated Search

    1997-09-30

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  20. 13 CFR 134.212 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Summary decision. 134.212 Section... CASES BEFORE THE OFFICE OF HEARINGS AND APPEALS Rules of Practice for Most Cases § 134.212 Summary decision. (a) Grounds. A party may move for summary decision at any time as to all or any portion of the...

  1. 29 CFR 18.41 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Summary decision. 18.41 Section 18.41 Labor Office of the... ADMINISTRATIVE LAW JUDGES General § 18.41 Summary decision. (a) No genuine issue of material fact. (1) Where no.... Any final decision issued as a summary decision shall conform to the requirements for all final...

  2. 15 CFR 766.8 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Summary decision. 766.8 Section 766.8... PROCEEDINGS § 766.8 Summary decision. At any time after a proceeding has been initiated, a party may move for a summary decision disposing of some or all of the issues. The administrative law judge may render...

  3. 17 CFR 10.91 - Summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Summary disposition. 10.91... Disposition Without Full Hearing § 10.91 Summary disposition. (a) Filing of motions, answers. Any party who... decision as a matter of law may move for a summary disposition in his favor of all or any part of the...

  4. 25 CFR 2.17 - Summary dismissal.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Summary dismissal. 2.17 Section 2.17 Indians BUREAU OF... § 2.17 Summary dismissal. (a) An appeal under this part will be dismissed if the notice of appeal is... summary dismissal for the following causes: (1) If after the appellant is given an opportunity to amend...

  5. Naphthalene emissions from moth repellents or toilet deodorant blocks determined using head-space and small-chamber tests.

    PubMed

    Jo, Wan-Kuen; Lee, Jong-Hyo; Lim, Ho-Jin; Jeong, Woo-Sik

    2008-01-01

    The present study investigated the emissions of naphthalene and other compounds from several different moth repellents (MRs) and one toilet deodorant block (TDB) currently sold in Korea, using a headspace analysis. The emission factors and emission rates of naphthalene were studied using a small-scale environmental chamber. Paper-type products emitted a higher concentration of the total volatile organic compounds (VOCs) (normalized to the weight of test piece) than ball-type products, which in turn emitted higher concentration than a gel-type product. In contrast, naphthalene was either the most or the second highest abundant compound for the four ball products, whereas for paper and gel products it was not detected or was detected at much lower levels. The abundance of naphthalene ranged between 18.4% and 37.3% for ball products. The results showed that the lower the air changes per hour (ACH) level was, the higher the naphthalene concentrations became. In general, a low ACH level suggests a low ventilation rate. The emission factor for naphthalene was nearly 100 times higher for a ball MR than for a gel or a paper MR. For the ball MR, the lower ACH level resulted in higher emission rate.

  6. Comparative analysis of the volatile composition of honeys from Brazilian stingless bees by static headspace GC-MS.

    PubMed

    de Lima Morais da Silva, Patricia; de Lima, Liliane Schier; Caetano, Ísis Kaminski; Torres, Yohandra Reyes

    2017-12-01

    The volatile composition of honeys produced by eight species of stingless bees collected in three municipalities in the state of Paraná (Brazil) was compared by combining static headspace GC-MS and chemometrics methods. Forty-four compounds were identified using NIST library and linear retention index relative to n-alkanes (C 8 -C 40 ). Linalool derivatives were the most abundant peaks in most honeys regardless geographical or entomological origin. However, Principal Component Analysis discriminated honeys from different geographical origins considering their distinctive minor volatile components. Honey samples from Guaraqueçaba were characterized by the presence of hotrienol while those from Cambará showed epoxylinalol, benzaldehyde and TDN as minor discriminating compounds. Punctual species such as Borá showed similar fingerprints regardless geographical origin, with ethyl octanoate and ethyl decanoate as characteristic intense chromatographic peaks, which may suggest a specialized behavior for nectar collection. Discriminant Analysis allowed correct geographic discrimination of most honeys produced in the three spots tested. We concluded that volatile profile of stingless bee honeys can be used to attest authenticity related to regional origin of honeys. Copyright © 2017. Published by Elsevier Ltd.

  7. Direct thermal desorption in the analysis of cheese volatiles by gas chromatography and gas chromatography-mass spectrometry: comparison with simultaneous distillation-extraction and dynamic headspace.

    PubMed

    Valero, E; Sanz, J; Martínez-Castro, I

    2001-06-01

    Direct thermal desorption (DTD) has been used as a technique for extracting volatile components of cheese as a preliminary step to their gas chromatographic (GC) analysis. In this study, it is applied to different cheese varieties: Camembert, blue, Chaumes, and La Serena. Volatiles are also extracted using other techniques such as simultaneous distillation-extraction and dynamic headspace. Separation and identification of the cheese components are carried out by GC-mass spectrometry. Approximately 100 compounds are detected in the examined cheeses. The described results show that DTD is fast, simple, and easy to automate; requires only a small amount of sample (approximately 50 mg); and affords quantitative information about the main groups of compounds present in cheeses.

  8. AdaNET executive summary

    NASA Technical Reports Server (NTRS)

    Digman, R. Michael

    1988-01-01

    The goal of AdaNET is to transfer existing and emerging software engineering technology from the Federal government to the private sector. The views and perspectives of the current project participants on long and short term goals for AdaNET; organizational structure; resources and returns; summary of identified AdaNET services; and the summary of the organizational model currently under discussion are presented.

  9. 21 CFR 17.17 - Summary decisions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Summary decisions. 17.17 Section 17.17 Food and... PENALTIES HEARINGS § 17.17 Summary decisions. (a) At any time after the filing of a complaint, a party may... declarations under penalty of perjury), for a summary decision on any issue in the hearing. The other party may...

  10. Lichenysin, a cyclooctapeptide occurring in Chinese liquor jiannanchun reduced the headspace concentration of phenolic off-flavors via hydrogen-bond interactions.

    PubMed

    Zhang, Rong; Wu, Qun; Xu, Yan

    2014-08-20

    Nonvolatile compounds play important roles in the quality of alcoholic beverages. In our previous work, a type of cyclooctapeptide lichenysin was newly identified in Chinese strong-aroma type liquor. In this work, it was found that lichenysin could selectively affect aroma volatility in strong-aroma type (Jiannanchun) liquor. Interaction of lichenysin and volatile phenolic compounds (off-odors in strong-aroma type liquor) was characterized using headspace solid-phase microextraction coupled with gas chromatography-mass spectrometry (HS-SPME-GC-MS). HS-SPME results indicated that lichenysin very efficiently suppressed the volatility of phenolic compounds by 36-48% (P < 0.05). Thermodynamic analysis showed that the binding process was mainly mediated by hydrogen bonding. Furthermore, the mixture of lichenysin and 4-ethylguaiacol revealed intermolecular cross peaks between the aH (Val) of lichenysin and the 1H of 4-ethylguaiacol, by using nuclear Overhauser effect spectroscopy. This study will help to further understand the interaction mechanisms between flavor and nonvolatile matrix components in Chinese liquors.

  11. Rapid analysis of dissolved methane, ethylene, acetylene and ethane using partition coefficients and headspace-gas chromatography.

    PubMed

    Lomond, Jasmine S; Tong, Anthony Z

    2011-01-01

    Analysis of dissolved methane, ethylene, acetylene, and ethane in water is crucial in evaluating anaerobic activity and investigating the sources of hydrocarbon contamination in aquatic environments. A rapid chromatographic method based on phase equilibrium between water and its headspace is developed for these analytes. The new method requires minimal sample preparation and no special apparatus except those associated with gas chromatography. Instead of Henry's Law used in similar previous studies, partition coefficients are used for the first time to calculate concentrations of dissolved hydrocarbon gases, which considerably simplifies the calculation involved. Partition coefficients are determined to be 128, 27.9, 1.28, and 96.3 at 30°C for methane, ethylene, acetylene, and ethane, respectively. It was discovered that the volume ratio of gas-to-liquid phase is critical to the accuracy of the measurements. The method performance can be readily improved by reducing the volume ratio of the two phases. Method validation shows less than 6% variation in accuracy and precision except at low levels of methane where interferences occur in ambient air. Method detection limits are determined to be in the low ng/L range for all analytes. The performance of the method is further tested using environmental samples collected from various sites in Nova Scotia.

  12. Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

    PubMed

    Orazbayeva, Dina; Kenessov, Bulat; Psillakis, Elefteria; Nassyrova, Dayana; Bektassov, Marat

    2018-06-22

    A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC-MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5-100 ng L -1 ) 3-10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. The utilisation of two detectors for the determination of water in honey using headspace gas chromatography.

    PubMed

    Frink, Lillian A; Armstrong, Daniel W

    2016-08-15

    A headspace gas chromatography (HSGC) method was developed for the determination of water content in honey. This method was shown to work with five different honey varieties which had a range of water from 14-16%. It also utilised two different detectors, the thermal conductivity detector (TCD) and the barrier discharge ionisation detector (BID). This method needs no heating pretreatment step as in the current leading method, (i.e. the measurement of refractive index). The solvent-free procedure negates the possibility of solvent-compound interactions as well as solubility limitations, as is common with Karl Fischer titrations. It was also apparent that the classic loss on drying method consistently and substantially produced results that were lower than the correct values. This approach is shown to be rapid, with an analysis time of 4 min when using the TCD detector and under 3 min when utilising the BID detector. HSGC is feasible for the determination of water due to the new PEG-linked geminal dicationic ionic-liquid-coated GC capillary column. In addition it provides accurate and precise determinations of the water content in honey. When using the sensitive BID detector, other trace volatile compounds are observed as well. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. 78 FR 69434 - Post-Summary Corrections to Entry Summaries Filed in ACE Pursuant to the ESAR IV Test...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ...'s) Entry Summary, Accounts and Revenue (ESAR IV) test program concerning the processing of post... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Post-Summary Corrections to Entry Summaries Filed in ACE Pursuant to the ESAR IV Test: Modifications and Clarifications AGENCY: U.S...

  15. A novel method for the determination of adsorption partition coefficients of minor gases in a shale sample by headspace gas chromatography.

    PubMed

    Zhang, Chun-Yun; Hu, Hui-Chao; Chai, Xin-Sheng; Pan, Lei; Xiao, Xian-Ming

    2013-10-04

    A novel method has been developed for the determination of adsorption partition coefficient (Kd) of minor gases in shale. The method uses samples of two different sizes (masses) of the same material, from which the partition coefficient of the gas can be determined from two independent headspace gas chromatographic (HS-GC) measurements. The equilibrium for the model gas (ethane) was achieved in 5h at 120°C. The method also involves establishing an equation based on the Kd at higher equilibrium temperature, from which the Kd at lower temperature can be calculated. Although the HS-GC method requires some time and effort, it is simpler and quicker than the isothermal adsorption method that is in widespread use today. As a result, the method is simple and practical and can be a valuable tool for shale gas-related research and applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. A robust, simple, high-throughput technique for time-resolved plant volatile analysis in field experiments

    PubMed Central

    Kallenbach, Mario; Oh, Youngjoo; Eilers, Elisabeth J.; Veit, Daniel; Baldwin, Ian T.; Schuman, Meredith C.

    2014-01-01

    Summary Plant volatiles (PVs) mediate interactions between plants and arthropods, microbes, and other plants, and are involved in responses to abiotic stress. PV emissions are therefore influenced by many environmental factors, including herbivore damage, microbial invasion, and cues from neighboring plants, but also light regime, temperature, humidity, and nutrient availability. Thus an understanding of the physiological and ecological functions of PVs must be grounded in measurements reflecting PV emissions under natural conditions. However, PVs are usually sampled in the artificial environments of laboratories or climate chambers. Sampling of PVs in natural environments is difficult, limited by the need to transport, maintain, and power instruments, or use expensive sorbent devices in replicate. Ideally, PVs should be measured in natural settings with high replication, spatiotemporal resolution, and sensitivity, and at modest costs. Polydimethysiloxane (PDMS), a sorbent commonly used for PV sampling, is available as silicone tubing (ST) for as little as 0.60 €/m (versus 100-550 € apiece for standard PDMS sorbent devices). Small (mm-cm) ST pieces (STs) can be placed in any environment and used for headspace sampling with little manipulation of the organism or headspace. STs have sufficiently fast absorption kinetics and large capacity to sample plant headspaces on a timescale of minutes to hours, and thus can produce biologically meaningful “snapshots” of PV blends. When combined with thermal desorption (TD)-GC-MS analysis – a 40-year-old and widely available technology – STs yield reproducible, sensitive, spatiotemporally resolved, quantitative data from headspace samples taken in natural environments. PMID:24684685

  17. 76 FR 37136 - Post-Summary Corrections to Entry Summaries Filed in ACE Pursuant to the ESAR IV Test

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-24

    ... Phased Out for Entry Summaries Filed in ACE The Post-Entry Amendment (PEA) test allows importers to amend... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Post-Summary Corrections to Entry Summaries Filed in ACE Pursuant to the ESAR IV Test AGENCY: U.S. Customs and Border Protection...

  18. 12 CFR 1805.101 - Summary.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Summary. 1805.101 Section 1805.101 Banks and Banking COMMUNITY DEVELOPMENT FINANCIAL INSTITUTIONS FUND, DEPARTMENT OF THE TREASURY COMMUNITY DEVELOPMENT FINANCIAL INSTITUTIONS PROGRAM General Provisions § 1805.101 Summary. Under the Community...

  19. Determination of N-vinyl-2-pyrrolidone and N-methyl-2-pyrrolidone in drugs using polypyrrole-based headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection.

    PubMed

    Mehdinia, Ali; Ghassempour, Alireza; Rafati, Hasan; Heydari, Rouhollah

    2007-03-21

    A headspace solid-phase microextraction and gas chromatography-nitrogen-phosphorous detection (HS-SPME-GC-NPD) method using polypyrrole (PPy) fibers has been introduced to determine two derivatives of pyrrolidone; N-vinyl-2-pyrrolidone (NVP) and N-methyl-2-pyrrolidone (NMP). Two types of PPy fibers, prepared using organic and aqueous media, were compared in terms of extraction efficiency and thermal stability. It was found that PPy film prepared using organic medium (i.e. acetonitrile) had higher extraction efficiency and more thermal stability compared to the film prepared in aqueous medium. To enhance the sensitivity of HS-SPME, the effects of pH, ionic strength, extraction time, extraction temperature and the headspace volume on the extraction efficiency were optimized. Using the results of this research, high sensitivity and selectivity had been achieved due to the combination of the high extraction efficiency of PPy film prepared in organic medium and the high sensitivity and selectivity of nitrogen-phosphorous detection. Linear range of the analytes was found to be between 1.0 and 1000 microg L(-1) with regression coefficients (R(2)) of 0.998 and 0.997 for NVP and NMP, consequently. Limits of detection (LODs) were 0.074 and 0.081 microg L(-1) for NVP and NMP, respectively. Relative standard deviation (R.S.D.) for five replications of analyses was found to be less than 6.0%. In real samples the mean recoveries were 94.81% and 94.15% for NVP and NMP, respectively. The results demonstrated the suitability of the HS-SPME technique for analyzing NVP and NMP in two different pharmaceutical matrices. In addition, the method was used for simultaneous detection of NVP, 2-pyrrolidone (2-Pyr), gamma-butyrolactone (GBL) and ethanolamine (EA) compounds.

  20. A molybdenum disulfide/reduced graphene oxide fiber coating coupled with gas chromatography-mass spectrometry for the saponification-headspace solid-phase microextraction of polychlorinated biphenyls in food.

    PubMed

    Lv, Fangying; Gan, Ning; Cao, Yuting; Zhou, You; Zuo, Rongjie; Dong, Youren

    2017-11-24

    In this work, the molybdenum disulfide/reduced graphene oxide (MoS 2 /RGO) composite material was synthesized as a fiber coating to extract seven indicator polychlorinated biphenyls (PCBs; PCB28, PCB52, PCB101, PCB118, PCB138, PCB153, and PCB180) present in food via a saponification-headspace solid-phase microextraction assay (saponification-HS-SPME). The MoS 2 /RGO coating was prepared and deposited on a stainless steel wire with the help of a silicone sealant and used as an SPME fiber. The alkali solution dissolved the fat and helped in releasing the PCBs present in milk to the headspace for extraction under 100°C. Following desorption in the inlet, the targets were quantified by gas chromatography-mass spectrometry. The effects of sorbent dosage, extraction time, added salts, and stirring rate on the extraction efficiency were investigated. The new coating was able to adsorb a higher amount of analytes, which was about 1.1-2.9 times in comparison with the commercially available SPME fiber (coated with divinylbenzene/carboxen/polydimethylsiloxane). It also showed the highest adsorption capability toward PCBs, which was 1.5-2.7 times that of the prepared RGO modified fiber. Moreover, MoS 2 also showed a strong affinity toward PCBs in a manner similar to its affinity for graphene. The developed method is simple and environmentally friendly as it does not require any organic solvents. Furthermore, it exhibits good sensitivity with detection limits less than 0.1ngmL -1 , linearity (0.25-100ngmL -1 ), and reproducibility (relative standard deviation below 10% for n=3). The novel SPME fibers are inexpensive, reusable, and can be easily prepared and manipulated. In addition, the saponification-HS-SPME assay was also found to be suitable for screening persistent organic pollutants in dairy products. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Results for the first quarter calendar year 2017 tank 50H salt solution sample

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Crawford, C. L.

    2017-04-12

    In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pumpmore » shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.« less

  2. Generating Concise Natural Language Summaries.

    ERIC Educational Resources Information Center

    McKeown, Kathleen; And Others

    1995-01-01

    Presents an approach to summarization that combines information from multiple facts into a single sentence using linguistic constructions. Describes two applications: one produces summaries of basketball games, and the other contains summaries of telephone network planning activity. Both summarize input data as opposed to full text. Discusses…

  3. Determination of the solubility of low volatility liquid organic compounds in water using volatile-tracer assisted headspace gas chromatography.

    PubMed

    Zhang, Shu-Xin; Chai, Xin-Sheng; Barnes, Donald G

    2016-02-26

    This study reports a new headspace gas chromatographic method (HS-GC) for the determination of water solubility of low volatility liquid organic compounds (LVLOs). The HS-GC analysis was performed on a set of aqueous solutions containing a range of concentrations of toluene-spiked (as a tracer) LVLOs, from under-saturation to over-saturation. A plot of the toluene tracer GC signal vs. the concentration of the LVLO results in two lines of different slopes that intersect at the concentration corresponding to the compound's solubility in water. The results showed that the HS-GC method has good precision (RSD <6.3%) and good accuracy, in which the relative deference between the data measured by the HS-GC method and the reference method were within 6.0%. The HS-GC method is simple and particularly suitable for measuring the solubility of LVLOs at elevated temperatures. This approach should be of special interest to those concerned about the impact of the presence of low-volatility organic liquids in waters of environmental and biological systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Forming and sustaining partnerships to provide integrated services for young people: an overview based on the headspace Geelong experience.

    PubMed

    Callaly, Tom; von Treuer, Kathryn; van Hamond, Toni; Windle, Kelly

    2011-02-01

    To discuss critical considerations in the formation and maintenance of agency partnerships designed to provide integrated care for young people. Two years after its establishment, an evaluation of the headspace Barwon collaboration and a review of the health-care and management literature on agency collaboration were conducted. The principal findings together with the authors' experience working at establishing and maintaining the partnership are used to discuss critical issues in forming and maintaining inter-agency partnerships. Structural and process considerations are necessary but not sufficient for the successful formation and maintenance of inter-agency partnerships and integrated care provision. Specifically, organizational culture change and staff engagement is a significant challenge and planning for this is essential and often neglected. Although agreeing on common goals and objectives is an essential first step in forming partnerships designed to provide integrated care, goodwill is not enough, and the literature consistently shows that most collaborations fail to meet their objectives. Principles and lessons of organizational behaviour and management practices in the business sector can contribute a great deal to partnership planning. © 2011 Blackwell Publishing Asia Pty Ltd.

  5. Sexual Harassment and Organizational Outcomes Executive Summary

    DTIC Science & Technology

    2011-10-01

    quid pro quo type of Sexual harassment and Organizational, 4 sexual harassment (e.g., sexual coercion). This should drive organizational efforts to... Sexual Harassment and Organizational Outcomes Executive Summary Charlie L. Law DEFENSE EQUAL...Executive Summary] No. 99-11 Sexual harassment and Organizational, 2 Executive Summary Issue

  6. 42 CFR 422.684 - Prehearing and summary judgment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Prehearing and summary judgment. 422.684 Section... Appeals § 422.684 Prehearing and summary judgment. (a) Prehearing. The hearing officer may schedule a...) Summary judgment. Either party to the hearing may ask the hearing officer to rule on a motion for summary...

  7. 15 CFR 904.210 - Summary decision.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE GENERAL REGULATIONS CIVIL PROCEDURES Hearing and Appeal Procedures General § 904.210 Summary decision. The Judge may render a summary decision...

  8. 12 CFR 1806.101 - Summary.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Summary. 1806.101 Section 1806.101 Banks and Banking COMMUNITY DEVELOPMENT FINANCIAL INSTITUTIONS FUND, DEPARTMENT OF THE TREASURY BANK ENTERPRISE AWARD PROGRAM General Provisions § 1806.101 Summary. (a) Under the Bank Enterprise Award Program, the...

  9. Analytical validation applied to simultaneous determination of solvents dichloromethane (DCM), methyl isobutyl ketone (MIBK), tetrahydrofuran (THF) and toluene (TOL) in urine by headspace extraction and injection on chromatographic system with a flame ionization detector

    NASA Astrophysics Data System (ADS)

    Muna, E. D. M.; Pereira, R. P.

    2016-07-01

    The determination of the volatile organic solvents dichloromethane (DCM), methyl isobutyl ketone (MIBK), tetrahydrofuran (THF) and toluene (TOL) is applied on toxicological monitoring of employees in various industrial activities. The gas chromatography technique with flame ionization detector and headspace injection system has been applied. The analytical procedure developed allows the simultaneous determination of the above-mentioned solvents and the accuracy of the method was tested following the INMETRO guidelines through the DOQ-CGRE 008 Rev.04-July/2011.

  10. 19 CFR 151.41 - Information on entry summary.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Information on entry summary. 151.41 Section 151... Products § 151.41 Information on entry summary. On the entry summary for petroleum or petroleum products in.... If the exact volumetric quantity cannot be determined in advance, the entry summary may be made for...

  11. 49 CFR 511.25 - Summary decision and order.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Summary decision and order. 511.25 Section 511.25...; Interlocutory Appeals; Summary Judgment; Settlement § 511.25 Summary decision and order. (a) Motion. Any party may move, with a supporting memorandum, for a Summary Decision and Order in its favor upon all or any...

  12. The Use of Summaries in Studying Texts.

    ERIC Educational Resources Information Center

    Duchastel, Philippe C.

    1983-01-01

    Presents a scheme for comparing the text-learning outcomes derivable from study of either text or a summary of the text and considers some practical study strategies students might adopt when summaries are available and when they are not. The value of summaries in instructional situations is discussed. (MBR)

  13. 30 CFR 44.40 - Motion for summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Motion for summary decision. 44.40 Section 44... Summary Decisions § 44.40 Motion for summary decision. (a) Any party may, at least 20 days before the date... summary decision on all or any part of the proceeding. Any other party may, within 10 days after service...

  14. 29 CFR 1905.40 - Motion for summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 5 2010-07-01 2010-07-01 false Motion for summary decision. 1905.40 Section 1905.40 Labor...-STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 Summary Decisions § 1905.40 Motion for summary decision... part, move with or without supporting affidavits for a summary decision in his favor on all or any part...

  15. 12 CFR 308.30 - Partial summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... PRACTICE AND PROCEDURE Uniform Rules of Practice and Procedure § 308.30 Partial summary disposition. If the administrative law judge determines that a party is entitled to summary disposition as to certain claims only, he... issues must be ordered. Those claims for which the administrative law judge has determined that summary...

  16. 5 CFR 2423.27 - Summary judgment motions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... judgment as a matter of law. Such motions shall be supported by documents, affidavits, applicable precedent... 5 Administrative Personnel 3 2011-01-01 2011-01-01 false Summary judgment motions. 2423.27 Section..., Prehearing Procedures § 2423.27 Summary judgment motions. (a) Motions. Any party may move for a summary...

  17. 5 CFR 2423.27 - Summary judgment motions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... judgment as a matter of law. Such motions shall be supported by documents, affidavits, applicable precedent... 5 Administrative Personnel 3 2012-01-01 2012-01-01 false Summary judgment motions. 2423.27 Section..., Prehearing Procedures § 2423.27 Summary judgment motions. (a) Motions. Any party may move for a summary...

  18. 12 CFR 1780.32 - Partial summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 7 2010-01-01 2010-01-01 false Partial summary disposition. 1780.32 Section... § 1780.32 Partial summary disposition. If the presiding officer determines that a party is entitled to summary disposition as to certain claims only, he shall defer submitting a recommended decision to the...

  19. Correlation of the summary method with learning styles.

    PubMed

    Sarikcioglu, Levent; Senol, Yesim; Yildirim, Fatos B; Hizay, Arzu

    2011-09-01

    The summary is the last part of the lesson but one of the most important. We aimed to study the relationship between the preference of the summary method (video demonstration, question-answer, or brief review of slides) and learning styles. A total of 131 students were included in the present study. An inventory was prepared to understand the students' learning styles, and a satisfaction questionnaire was provided to determine the summary method selection. The questionnaire and inventory were collected and analyzed. A comparison of the data revealed that the summary method with video demonstration received the highest score among all the methods tested. Additionally, there were no significant differences between learning styles and summary method with video demonstration. We suggest that such a summary method should be incorporated into neuroanatomy lessons. Since anatomy has a large amount of visual material, we think that it is ideally suited for this summary method.

  20. Covering the different steps of the coffee processing: Can headspace VOC emissions be exploited to successfully distinguish between Arabica and Robusta?

    PubMed

    Colzi, Ilaria; Taiti, Cosimo; Marone, Elettra; Magnelli, Susanna; Gonnelli, Cristina; Mancuso, Stefano

    2017-12-15

    This work was performed to evaluate the possible application of PTR-ToF-MS technique in distinguishing between Coffea arabica (Arabica) and Coffea canephora var. robusta (Robusta) commercial stocks in each step of the processing chain (green beans, roasted beans, ground coffee, brews). volatile organic compounds (VOC) spectra from coffee samples of 7 Arabica and 6 Robusta commercial stocks were recorded and submitted to multivariate statistical analysis. Results clearly showed that, in each stage of the coffee processing, the volatile composition of coffee is highly influenced by the species. Actually, with the exception of green beans, PTR-ToF-MS technique was able to correctly recognize Arabica and Robusta samples. Particularly, among 134 tentatively identified VOCs, some masses (16 for roasted coffee, 12 for ground coffee and 12 for brewed coffee) were found to significantly discriminate the two species. Therefore, headspace VOC analyses was showed to represent a valuable tool to distinguish between Arabica and Robusta. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Fast analysis of principal volatile compounds in crude and processed Atractylodes macrocephala by an automated static headspace gas chromatography-mass spectrometry

    PubMed Central

    Zhang, Jida; Cao, Gang; Xia, Yunhua; Wen, Chengping; Fan, Yongsheng

    2014-01-01

    Objective: Atractylodes macrocephala, a famous herbal medicine, is used extensively in the practice of Traditional Chinese Medicine (TCM). Processing procedure is a common approach that usually occurs before A. macrocephala is prescribed. This paper describes a sensitive and specific assay for the determination of principal volatile compounds in crude and processed A. macrocephala. Materials and Methods: The present study concentrated on the development of a static headspace gas chromatography-mass spectrometry (SHS-GC/MS) for separating and identifying of volatile compounds from crude and processed A. macrocephala samples. Results: The results showed that the volatile oil in crude and processed A. macrocephala was markedly quantitatively and qualitatively different. Processing resulted in the reduction of volatile oil contents and variation of chemical compositions in A. macrocephala. Conclusion: The proposed method proved that SHS-GC/MS is rapid and specific, and should also be useful for evaluating the quality of crude and processed medicinal herbs. PMID:25210311

  2. The application of headspace gas chromatography coupled to tandem quadrupole mass spectrometry for the analysis of furan in baby food samples.

    PubMed

    Pugajeva, Iveta; Rozentale, Irina; Viksna, Arturs; Bartkiene, Elena; Bartkevics, Vadims

    2016-12-01

    Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC-MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021μgkg(-1) and a limit of quantification of 0.071μgkg(-1). The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9μgkg(-1), indicating that infants whose sole diet comprises baby food sold in jars and cans are exposed constantly to furan. Samples containing vegetables and meat had higher levels of furan than those containing only fruits. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A novel multiple headspace extraction gas chromatographic method for measuring the diffusion coefficient of methanol in water and in olive oil.

    PubMed

    Zhang, Chun-Yun; Chai, Xin-Sheng

    2015-03-13

    A novel method for the determination of the diffusion coefficient (D) of methanol in water and olive oil has been developed. Based on multiple headspace extraction gas chromatography (MHE-GC), the methanol released from the liquid sample of interest in a closed sample vial was determined in a stepwise fashion. A theoretical model was derived to establish the relationship between the diffusion coefficient and the GC signals from MHE-GC measurements. The results showed that the present method has an excellent precision (RSD<1%) in the linear fitting procedure and good accuracy for the diffusion coefficients of methanol in both water and olive oil, when compared with data reported in the literature. The present method is simple and practical and can be a valuable tool for the determination of the diffusion coefficient of volatile analyte(s) into food simulants from food and beverage packaging material, both in research studies and in actual applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. 12 CFR 263.30 - Partial summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 3 2010-01-01 2010-01-01 false Partial summary disposition. 263.30 Section 263... SYSTEM RULES OF PRACTICE FOR HEARINGS Uniform Rules of Practice and Procedure § 263.30 Partial summary disposition. If the administrative law judge determines that a party is entitled to summary disposition as to...

  5. 41 CFR 60-2.31 - Program summary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Program summary. 60-2.31...-AFFIRMATIVE ACTION PROGRAMS Miscellaneous § 60-2.31 Program summary. The affirmative action program must be summarized and updated annually. The program summary must be prepared in a format which will be prescribed by...

  6. 12 CFR 19.30 - Partial summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 1 2010-01-01 2010-01-01 false Partial summary disposition. 19.30 Section 19... PROCEDURE Uniform Rules of Practice and Procedure § 19.30 Partial summary disposition. If the administrative law judge determines that a party is entitled to summary disposition as to certain claims only, he or...

  7. Headspace Analysis of Volatile Compounds Using Segemented Chirped-Pulse Fourier Transform Mm-Wave Spectroscopy

    NASA Astrophysics Data System (ADS)

    Harris, Brent; Steber, Amanda; Pate, Brooks

    2014-06-01

    A chirped-pulse Fourier transform mm-wave spectrometer has been tested in analytical chemistry applications of headspace analysis of volatile species. A solid-state mm-wave light source (260-290 GHz) provides 30-50 mW of power. This power is sufficient to achieve optimal excitation of individual transitions of molecules with dipole moments larger than about 0.1 D. The chirped-pulse spectrometer has near 100% measurement duty cycle using a high-speed digitizer (4 GS/s) with signal accumulation in an FPGA. The combination of the ability to perform optimal pulse excitation and near 100% measurement duty cycle gives a spectrometer that is fully optimized for trace detection. The performance of the instrument is tested using an EPA sample (EPA VOC Mix 6 - Supelco) that contains a set of molecules that are fast eluting on gas chromatographs and, as a result, present analysis challenges to mass spectrometry. The ability to directly analyze the VOC mixture is tested by acquiring the full bandwidth (260-290 GHz) spectrum in a "high dynamic range" measurement mode that minimizes spurious spectrometer responses. The high-resolution of molecular rotational spectroscopy makes it easy to analyze this mixture without the need for chemical separation. The sensitivity of the instrument for individual molecule detection, where a single transition is polarized by the excitation pulse, is also tested. Detection limits in water will be reported. In the case of chloromethane, the detection limit (0.1 microgram/L), matches the sensitivity reported in the EPA measurement protocol (EPA Method 524) for GC/MS.

  8. Headspace solid-phase microextraction (HS-SPME) and liquid-liquid extraction (LLE): comparison of the performance in classification of ecstasy tablets. Part 2.

    PubMed

    Bonadio, Federica; Margot, Pierre; Delémont, Olivier; Esseiva, Pierre

    2008-11-20

    Headspace solid-phase microextraction (HS-SPME) is assessed as an alternative to liquid-liquid extraction (LLE) currently used for 3,4-methylenedioxymethampethamine (MDMA) profiling. Both methods were compared evaluating their performance in discriminating and classifying samples. For this purpose 62 different seizures were analysed using both extraction techniques followed by gas chromatography-mass spectroscopy (GC-MS). A previously validated method provided data for HS-SPME, whereas LLE data were collected applying a harmonized methodology developed and used in the European project CHAMP. After suitable pre-treatment, similarities between sample pairs were studied using the Pearson correlation. Both methods enable to distinguish between samples coming from the same pre-tabletting batches and samples coming from different pre-tabletting batches. This finding emphasizes the use of HS-SPME as an effective alternative to LLE, with additional advantages such as sample preparation and a solvent-free process.

  9. Characterization of Aronia melanocarpa volatiles by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation/extraction (SDE), and gas chromatography-olfactometry (GC-O) methods.

    PubMed

    Kraujalytė, Vilma; Leitner, Erich; Venskutonis, Petras Rimantas

    2013-05-22

    The profiles of volatile constituents of berry fruit of two Aronia melanocarpa genotypes were evaluated by headspace-solid-phase microextraction (HS-SPME), simultaneous distillation and extraction (SDE), and gas chromatography-olfactometry (GC-O). In total, 74 volatile compounds were identified in chokeberry juice, 3-penten-2-one, 3,9-epoxy-p-menth-1-ene, and benzaldehyde being the most abundant constituents; however, their percentage concentrations were remarkably different in the HS-SPME and SDE profiles. Twenty two aroma-active compounds were detected and characterized by the trained panelists in HS-SPME using GC-O detection frequency analysis. Olfactometry revealed that ethyl-2-methyl butanoate, ethyl-3-methyl butanoate, ethyl decanoate ("fruity" aroma notes), nonanal ("green" notes), unidentified compound possessing "moldy" odor, and some other volatiles may be very important constituents in formation of chokeberry aroma of both analyzed plant cultivars.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickenheim, B.; Hansen, E.; Leishear, R.

    A 10-inch READCO mixer is used for mixing the premix (45 (wt%) fly ash, 45 wt% slag, and 10 wt% portland cement) with salt solution in the Saltstone Production Facility (SPF). The Saltstone grout free falls into the grout hopper which feeds the suction line leading to the Watson SPX 100 duplex hose pump. The Watson SPX 100 pumps the grout through approximately 1500 feet of piping prior to being discharged into the Saltstone Disposal Facility (SDF) vaults. The existing grout hopper has been identified by the Saltstone Enhanced Low Activity Waste Disposal (ELAWD) project for re-design. The current nominalmore » working volume of this hopper is 12 gallons and does not permit handling an inadvertent addition of excess dry feeds. Saltstone Engineering has proposed a new hopper tank that will have a nominal working volume of 300 gallons and is agitated with a mechanical agitator. The larger volume hopper is designed to handle variability in the output of the READCO mixer and process upsets without entering set back during processing. The objectives of this task involve scaling the proposed hopper design and testing the scaled hopper for the following processing issues: (1) The effect of agitation on radar measurement. Formation of a vortex may affect the ability to accurately measure the tank level. The agitator was run at varying speeds and with varying grout viscosities to determine what parameters cause vortex formation and whether measurement accuracy is affected. (2) A dry feeds over addition. Engineering Calculating X-ESR-Z-00017 1 showed that an additional 300 pounds of dry premix added to a 300 gallon working volume would lower the water to premix ratio (W/P) from the nominal 0.60 to 0.53 based on a Salt Waste Processing Facility (SWPF) salt simulant. A grout with a W/P of 0.53 represents the upper bound of grout rheology that could be processed at the facility. A scaled amount of dry feeds will be added into the hopper to verify that this is a recoverable

  11. Pilot Research Summaries, 1967-1970.

    ERIC Educational Resources Information Center

    Casey, James L.; Hayes, Larry K.

    This report contains one-page summaries of a majority of the 134 research studies funded through the Oklahoma Consortium on Research Development. The research covers the whole spectrum of academic topics , from nursing to ecology to art to politics.. Brief summaries of a majority of the 37 development seminars funded through the Consortium are…

  12. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    PubMed

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  13. Subsystems component definitions summary program

    NASA Technical Reports Server (NTRS)

    Scott, A. Don; Thomas, Carolyn C.; Simonsen, Lisa C.; Hall, John B., Jr.

    1991-01-01

    A computer program, the Subsystems Component Definitions Summary (SUBCOMDEF), was developed to provide a quick and efficient means of summarizing large quantities of subsystems component data in terms of weight, volume, resupply, and power. The program was validated using Space Station Freedom Program Definition Requirements Document data for the internal and external thermal control subsystem. Once all component descriptions, unit weights and volumes, resupply, and power data are input, the user may obtain a summary report of user-specified portions of the subsystem or of the entire subsystem as a whole. Any combination or all of the parameters of wet and dry weight, wet and dry volume, resupply weight and volume, and power may be displayed. The user may vary the resupply period according to individual mission requirements, as well as the number of hours per day power consuming components operate. Uses of this program are not limited only to subsystem component summaries. Any applications that require quick, efficient, and accurate weight, volume, resupply, or power summaries would be well suited to take advantage of SUBCOMDEF's capabilities.

  14. Development of a Direct Headspace Collection Method from Arabidopsis Seedlings Using HS-SPME-GC-TOF-MS Analysis

    PubMed Central

    Kusano, Miyako; Iizuka, Yumiko; Kobayashi, Makoto; Fukushima, Atsushi; Saito, Kazuki

    2013-01-01

    Plants produce various volatile organic compounds (VOCs), which are thought to be a crucial factor in their interactions with harmful insects, plants and animals. Composition of VOCs may differ when plants are grown under different nutrient conditions, i.e., macronutrient-deficient conditions. However, in plants, relationships between macronutrient assimilation and VOC composition remain unclear. In order to identify the kinds of VOCs that can be emitted when plants are grown under various environmental conditions, we established a conventional method for VOC profiling in Arabidopsis thaliana (Arabidopsis) involving headspace-solid-phase microextraction-gas chromatography-time-of-flight-mass spectrometry (HS-SPME-GC-TOF-MS). We grew Arabidopsis seedlings in an HS vial to directly perform HS analysis. To maximize the analytical performance of VOCs, we optimized the extraction method and the analytical conditions of HP-SPME-GC-TOF-MS. Using the optimized method, we conducted VOC profiling of Arabidopsis seedlings, which were grown under two different nutrition conditions, nutrition-rich and nutrition-deficient conditions. The VOC profiles clearly showed a distinct pattern with respect to each condition. This study suggests that HS-SPME-GC-TOF-MS analysis has immense potential to detect changes in the levels of VOCs in not only Arabidopsis, but other plants grown under various environmental conditions. PMID:24957989

  15. Microbes a Tool for the Remediation of Organotin Pollution Determined by Static Headspace Gas Chromatography-Mass Spectrometry.

    PubMed

    Finnegan, Christopher; Ryan, David; Enright, Anne-Marie; Garcia-Cabellos, Guiomar

    2018-03-10

    Tributyltin (TBT) is one of the most toxic anthropogenic compounds introduced into the marine environment. Despite its global ban in 2008, TBT is still a problem of great concern due to its high affinity for particulate matter, providing a direct and potentially persistent route of entry into benthic sediments. Bioremediation strategies may constitute an alternative approach to conventional physicochemical methods, benefiting from the microorganism's potential to metabolize anthropogenic compounds. In this work, a simple, precise and accurate static headspace gas chromatography method was developed to investigate the ability of TBT degrading microbes in sedimentary microcosms over a period of 120 days. The proposed method was validated for linearity, repeatability, accuracy, specificity, limit of detection and limit of quantification. The method was subsequently successfully applied for the detection and quantification of TBT and degradation compounds in sediment samples on day 0, 30, 60, 90 and 120 of the experiment employing the principles of green chemistry. On day 120 the concentration of TBT remaining in the microcosms ranged between 91.91 ng/g wet wt for the least effective microbial inoculant to 52.73 ng/g wet wt for the most effective microbial inoculant from a starting concentration of 100 ng/g wet wt.

  16. Mixed aqueous solutions as dilution media in the determination of residual solvents by static headspace gas chromatography.

    PubMed

    D'Autry, Ward; Zheng, Chao; Wolfs, Kris; Yarramraju, Sitaramaraju; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin

    2011-06-01

    Static headspace (HS) sampling has been commonly used to test for volatile organic chemicals, usually referred to as residual solvents (RS) in pharmaceuticals. If the sample is not soluble in water, organic solvents are used. However, these seriously reduce the sensitivity in the determination of some RS. Here, mixed aqueous dilution media (a mixture of water and an organic solvent like dimethyl formamide, dimethyl sulfoxide or dimethyl acetamide) were studied as alternative media for static HS-gas chromatographic analysis. Although it has been known that mixed aqueous dilution media can often improve sensitivity for many RS, this study used a systematic approach to investigate phase volumes and the organic content in the HS sampling media. Reference solutions using 18 different class 1, 2 and 3 RS were evaluated. The effect of salt addition was also studied in this work. A significant increase in the peak area was observed for all RS using mixed aqueous dilution media, when compared with organic solvents alone. Matrix effects related to the mixed aqueous dilution media were also investigated and reported. Repeatability and linearity obtained with mixed aqueous dilution media were found to be similar to those observed with pure organic solvents. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. WIND Toolkit Offshore Summary Dataset

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Draxl, Caroline; Musial, Walt; Scott, George

    This dataset contains summary statistics for offshore wind resources for the continental United States derived from the Wind Integration National Datatset (WIND) Toolkit. These data are available in two formats: GDB - Compressed geodatabases containing statistical summaries aligned with lease blocks (aliquots) stored in a GIS format. These data are partitioned into Pacific, Atlantic, and Gulf resource regions. HDF5 - Statistical summaries of all points in the offshore Pacific, Atlantic, and Gulf offshore regions. These data are located on the original WIND Toolkit grid and have not been reassigned or downsampled to lease blocks. These data were developed under contractmore » by NREL for the Bureau of Oceanic Energy Management (BOEM).« less

  18. Direct screening of ground water samples for fuel oxygenates by headspace liquid phase microextraction-gas chromatography.

    PubMed

    Kaykhaii, Massoud; Mirbaloochzahi, Mohammad Reza

    2008-12-01

    The applicability of the headspace liquid phase microextraction and gas chromatography (HS-LPME/GC) for the expeditious and reliable screening of 68 well water samples for selected fuel oxygenates compounds, viz. methyl tertiary-butyl ether (MTBE), tertiary-amyl methyl ether (TAME), ethyl tertiary-butyl ether (ETBE) and n-butyl ethyl ether (n-BEE) has been evaluated. The method used 3 microl of 1:1 benzyl alcohol/1-octanol as extraction solvent, 20 min extraction time with stirring at 1,250 rpm, at 20 degrees C and salt addition of a mixture of 0.3 g ml(-1) sodium sulphate/0.1 g ml(-1) sodium chloride. The enrichment factors of this method were from 171 to 571. Limits of detection were in the range of 77-110 ng l(-1). The relative standard deviations (RSDs) at 0.05, 0.50 and 10.0 mg l(-1) of spiking levels were in the range of 1.28-6.80% with recoveries between 96.2 and 106.0%. Sixty-eight groundwater wells that were located near different gasoline reservoirs in eight largest cities of the Sistan and Balouchestan province were screened by the method. Eight contaminated wells were identified contained MTBE at levels between 0.3 and 1.7 mg l(-1). In all cases, other target analytes were at low concentrations or not detected.

  19. Suitability of polydimethylsiloxane rods for the headspace sorptive extraction of polybrominated diphenyl ethers from water samples.

    PubMed

    Montes, R; Rodríguez, I; Rubí, E; Cela, R

    2007-03-02

    The suitability of an inexpensive polydimethysiloxane (PDMS) sorbent, produced on an industrial scale, for the extraction of polybrominated diphenyl ethers (PBDEs), from tetra- to hexabrominated congeners, from water samples was assessed. Experiments were carried out using samples spiked with a pentabromo diphenyl ether (pentaBDE) mixture, PDMS rods with a diameter of 2 mm and gas chromatography with micro-electron-capture detection (GC-micro-ECD). Influence of several variables on the efficiency of the enrichment step and the further desorption of the analytes was investigated in detail. The best performance was achieved in the headspace sorptive extraction (HSSE) mode, at 95 degrees C, using 80 mL water samples containing a 30% of sodium chloride. Extractions were performed overnight using disposable PDMS rods with a length of 10 mm (31 microL volume). Analytes were further recovered from the PDMS sorbent using just 1 mL of diethyl ether. This solvent was evaporated and extracts reconstituted with 25 microL of isooctane. Under final working conditions absolute extraction efficiencies from 69 to 93% and enrichment factors higher than 2200 folds were achieved for all species. The proposed method provided acceptable precisions (relative standard deviations values under 12%), correlation coefficients higher than 0.998 and the yield of the HSSE process remained constant for different water samples.

  20. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2009-01-01

    This article presents summaries of three recent crisis management publications: (1) "School Violence: Associations With Control, Security/Enforcement, Educational/Therapeutic Approaches, and Demographic Factors," reviewed by Ashlee Barton; (2) "The Relationship Between Cognitive Coping Styles and PTSD in Survivors of Traffic Accidents," summarized…

  1. Summary travel characteristics : District of Columbia

    DOT National Transportation Integrated Search

    1997-10-01

    The Summary Travel Characteristics publication series contains summary tables of travel statistics for census regions and divisions, States, and metropolitan areas. The tables in this report provide an overview of the findings of the American Travel ...

  2. Mutual interference between statistical summary perception and statistical learning.

    PubMed

    Zhao, Jiaying; Ngo, Nhi; McKendrick, Ryan; Turk-Browne, Nicholas B

    2011-09-01

    The visual system is an efficient statistician, extracting statistical summaries over sets of objects (statistical summary perception) and statistical regularities among individual objects (statistical learning). Although these two kinds of statistical processing have been studied extensively in isolation, their relationship is not yet understood. We first examined how statistical summary perception influences statistical learning by manipulating the task that participants performed over sets of objects containing statistical regularities (Experiment 1). Participants who performed a summary task showed no statistical learning of the regularities, whereas those who performed control tasks showed robust learning. We then examined how statistical learning influences statistical summary perception by manipulating whether the sets being summarized contained regularities (Experiment 2) and whether such regularities had already been learned (Experiment 3). The accuracy of summary judgments improved when regularities were removed and when learning had occurred in advance. In sum, calculating summary statistics impeded statistical learning, and extracting statistical regularities impeded statistical summary perception. This mutual interference suggests that statistical summary perception and statistical learning are fundamentally related.

  3. Applications of Headspace Moisture Analysis for Investigating the Water Dynamics within a Sealed Vial Containing Freeze-dried Material.

    PubMed

    Cook, Isobel Ann; Ward, Kevin Richard

    2011-01-01

    We compare frequency modulation spectroscopy (FMS) as a method of headspace water analysis with the method of Karl Fischer coulometric titration (KF), which is widely used in the analysis of residual water in a freeze-dried material. Parameters relating to the type of formulation (amorphous, crystalline) and the freeze-drying cycle (temperature, pressure, time) were investigated in relation to the resulting headspace moisture (HSM) and total water. We describe the effect of stopper treatment and storage conditions on the HSM levels observed using FMS as a non-destructive method, which also allowed individual vials to be reanalyzed at a series of time points as part of a long-term monitoring exercise. The results of this study enabled a better understanding of the effect of stopper type and pre-lyophilization treatment on the HSM levels both immediately after freeze-drying and upon subsequent storage of the sealed vials of lyophilized material at different temperatures. A clear, linear relationship was observed between HSM and KF values for vials containing freeze-dried sucrose, implying a relatively straightforward interaction between water and the lyophilized cake for this material. Moisture mapping of all vials on one shelf of the freeze-dryer enabled further information to be obtained on the relationship of the formulation, vial, process conditions, equipment geometry, and performance on the intra-batch variability in HSM level and dynamics. It is believed that this could therefore represent a potentially useful technique for quality assurance and in the validation of lyophilization cycles, equipment, and scale-up. Lyophilization, also known as "freeze-drying," is a relatively old technique that has been used in its most basic form for thousands of years (e.g., preservation of fish and meat products). In its more advanced form it is used to preserve many medical products, for example, many vaccines are not stable in solution and therefore need to be dried to

  4. Evaluation of three headspace sorptive extraction coatings for the determination of volatile terpenes in honey using gas chromatography-mass spectrometry.

    PubMed

    Cacho, J I; Campillo, N; Viñas, P; Hernández-Córdoba, M

    2015-06-19

    Headspace sorptive extraction (HSSE) was used to preconcentrate seven monoterpenes (eucalyptol, linalool, menthol, geraniol, carvacrol, thymol and eugenol) for separation by gas chromatography and mass spectrometry (GC-MS). Three commercially available coatings for the stir bars, namely Polydimethylsiloxane (PDMS), polyacrilate (PA) and Ethylene glycol-silicone (EG-Silicone), were tested, and the influential parameters both in the adsorption and the thermal desorption steps were optimized. PDMS provided the best sensitivity for linalool, geraniol, menthol and eucalyptol, whereas EG-Silicone was best for extracting the phenolic monoterpenes studied. Considering the average obtained slopes from all compounds, PDMS pointed as the best option, and the analytical characteristics for the HSSE-TD-GC-MS method using this coating were obtained. Quantification of the samples was carried out by matrix-matched calibration using a synthetic honey. Detection limits ranged between 0.007 and 0.032 ng g(-1), depending on the compound. Twelve honey samples of different floral origins were analyzed using the HSSE-GC-MS method, the analytes being detected at concentrations up to 64 ng g(-1). Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Headspace-mass spectrometry determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers in soil samples using chemometrics.

    PubMed

    Esteve-Turrillas, F A; Armenta, S; Garrigues, S; Pastor, A; de la Guardia, M

    2007-03-21

    A simple and fast method has been developed for the determination of benzene, toluene and the mixture of ethylbenzene and xylene isomers (BTEX) in soils. Samples were introduced in 10 mL standard glass vials of a headspace (HS) autosampler together with 150 microL of 2,6,10,14-tetramethylpentadecane, heated at 90 degrees C for 10 min and introduced in the mass spectrometer by using a transfer line heated at 250 degrees C as interface. The volatile fraction of samples was directly introduced into the source of the mass spectrometer which was scanned from m/z 75 to 110. A partial least squares (PLS) multivariate calibration approach based on a classical 3(3) calibration model was build with mixtures of benzene, toluene and o-xylene in 2,6,10,14-tetramethylpentadecane for BTEX determination. Results obtained for BTEX analysis by HS-MS in different types of soil samples were comparables to those obtained by the reference HS-GC-MS procedure. So, the developed procedure allowed a fast identification and prediction of BTEX present in the samples without a prior chromatographic separation.

  6. Plain Language Summary: Adult Sinusitis (Sinus Infection).

    PubMed

    Caspersen, Leslie A; Walter, Lindsey M; Walsh, Sandra A; Rosenfeld, Richard M; Piccirillo, Jay F

    2015-08-01

    This plain language summary serves as an overview in explaining sinusitis (pronounced sign-you-side-tis). The purpose of this plain language summary is to provide patients with standard language explaining their condition in an easy-to-read format. This summary applies to those 18 years of age or older with sinusitis. The summary is featured as an FAQ (frequently asked question) format. The summary addresses how to manage and treat sinusitis symptoms. Adult sinusitis is often called a sinus infection. A healthcare provider may refer to a sinus infection as rhinosinusitis (pronounced rhi-no-sign-you-side-tis). This includes the nose as well as the sinuses in the name. A sinus infection is the swelling of the sinuses and nasal cavity.The summary is based on the published 2015 "Clinical Practice Guideline: Adult Sinusitis." The evidence-based guideline includes research to support more effective diagnosis and treatment of adult sinus infections. The guideline was developed as a quality improvement opportunity for managing sinus infections by creating clear recommendations to use in medical practice. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  7. Data on changes in red wine phenolic compounds, headspace aroma compounds and sensory profile after treatment of red wines with activated carbons with different physicochemical characteristics.

    PubMed

    Filipe-Ribeiro, Luís; Milheiro, Juliana; Matos, Carlos C; Cosme, Fernanda; Nunes, Fernando M

    2017-06-01

    Data in this article presents the changes on phenolic compounds, headspace aroma composition and sensory profile of a red wine spiked with 4-ethylphenol and 4-ethylguaiacol and treated with seven activated carbons with different physicochemical characteristics, namely surface area, micropore volume and mesopore volume ("Reduction of 4-ethylphenol and 4-ethylguaiacol in red wine by activated carbons with different physicochemical characteristics: impact on wine quality" Filipe-Ribeiro et al. (2017) [1]). Data on the physicochemical characteristics of the activated carbons are shown. Statistical data on the sensory expert panel consistency by General Procrustes Analysis is shown. Statistical data is also shown, which correlates the changes in chemical composition of red wines with the physicochemical characteristics of activated carbons used.

  8. Property Data Summaries for Advanced Materials

    National Institute of Standards and Technology Data Gateway

    SRD 150 NIST Property Data Summaries for Advanced Materials (Web, free access)   Property Data Summaries are topical collections of property values derived from surveys of published data. Thermal, mechanical, structural, and chemical properties are included in the collections.

  9. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2009-01-01

    This article presents summaries of two recent crisis management publications: (1) "Social Validity of the CISM Model for School Crisis Intervention," summarized by Jack R. Dempsey; and (2) "School Violence: Associations With Control, Security/Enforcement, Educational/Therapeutic Approaches, and Demographic Factors," summarized by Ashlee Barton.…

  10. Linked Micromaps: Statistical Summaries in a Spatial Context

    EPA Science Inventory

    Communicating summaries of spatial data to decision makers and the public is challenging. We present a graphical method that provides both a geographic context and a statistical summary for such spatial data. Monitoring programs have a need for such geographical summaries. For ...

  11. Key Frame Extraction in the Summary Space.

    PubMed

    Li, Xuelong; Zhao, Bin; Lu, Xiaoqiang; Xuelong Li; Bin Zhao; Xiaoqiang Lu; Lu, Xiaoqiang; Li, Xuelong; Zhao, Bin

    2018-06-01

    Key frame extraction is an efficient way to create the video summary which helps users obtain a quick comprehension of the video content. Generally, the key frames should be representative of the video content, meanwhile, diverse to reduce the redundancy. Based on the assumption that the video data are near a subspace of a high-dimensional space, a new approach, named as key frame extraction in the summary space, is proposed for key frame extraction in this paper. The proposed approach aims to find the representative frames of the video and filter out similar frames from the representative frame set. First of all, the video data are mapped to a high-dimensional space, named as summary space. Then, a new representation is learned for each frame by analyzing the intrinsic structure of the summary space. Specifically, the learned representation can reflect the representativeness of the frame, and is utilized to select representative frames. Next, the perceptual hash algorithm is employed to measure the similarity of representative frames. As a result, the key frame set is obtained after filtering out similar frames from the representative frame set. Finally, the video summary is constructed by assigning the key frames in temporal order. Additionally, the ground truth, created by filtering out similar frames from human-created summaries, is utilized to evaluate the quality of the video summary. Compared with several traditional approaches, the experimental results on 80 videos from two datasets indicate the superior performance of our approach.

  12. 40 CFR 35.532 - Requirements summary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Requirements summary. 35.532 Section 35.532 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE....532 Requirements summary. (a) Applicants and recipients of Performance Partnership Grants must meet...

  13. 40 CFR 35.132 - Requirements summary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Requirements summary. 35.132 Section 35.132 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY GRANTS AND OTHER FEDERAL ASSISTANCE... Requirements summary. Applicants and recipients of Performance Partnership Grants must meet: (a) The...

  14. Technology for Space Station Evolution. Executive summary and overview

    NASA Technical Reports Server (NTRS)

    1990-01-01

    NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution 16-19 Jan. 1990. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the technology discipline presentations. The Executive Summary and Overview contains an executive summary for the workshop, the technology discipline summary packages, and the keynote address. The executive summary provides a synopsis of the events and results of the workshop and the technology discipline summary packages.

  15. Speciation analysis of organotin compounds in human urine by headspace solid-phase micro-extraction and gas chromatography with pulsed flame photometric detection.

    PubMed

    Valenzuela, Aníbal; Lespes, Gaëtane; Quiroz, Waldo; Aguilar, Luis F; Bravo, Manuel A

    2014-07-01

    A new headspace solid-phase micro-extraction (HS-SPME) method followed by gas chromatography with pulsed flame photometric detection (GC-PFPD) analysis has been developed for the simultaneous determination of 11 organotin compounds, including methyl-, butyl-, phenyl- and octyltin derivates, in human urine. The methodology has been validated by the analysis of urine samples fortified with all analytes at different concentration levels, and recovery rates above 87% and relative precisions between 2% and 7% were obtained. Additionally, an experimental-design approach has been used to model the storage stability of organotin compounds in human urine, demonstrating that organotins are highly degraded in this medium, although their stability is satisfactory during the first 4 days of storage at 4 °C and pH=4. Finally, this methodology was applied to urine samples collected from harbor workers exposed to antifouling paints; methyl- and butyltins were detected, confirming human exposure in this type of work environment. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. 16 CFR 1025.25 - Summary decisions and orders.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Summary decisions and orders. 1025.25... ADJUDICATIVE PROCEEDINGS Prehearing Procedures, Motions, Interlocutory Appeals, Summary Judgments, Settlements § 1025.25 Summary decisions and orders. (a) Motion. Any party may file a motion, with a supporting...

  17. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2011-01-01

    This column features summaries of five research articles relevant to school crisis response. The first, "High School Teachers' Experiences With Suicidal Students," summarized by Robyn Bratica, offers the results of a study examining high school teachers' experiences with suicidal students and suggests that contact with suicidal students is very…

  18. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2010-01-01

    This column features summaries of research articles from 3 recent crisis management publications. The first, "School Shootings and Counselor Leadership: Four Lessons from the Field" summarized by Kristi Fenning, was conducted as the result of the increased demand for trained crisis personnel on school campuses. Survey participants were…

  19. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2009-01-01

    This article presents summaries of four recent crisis management publications: (1) "Crisis Intervention for Children/Caregivers Exposed to Intimate Partner Violence," summarized by Donna DeVaughn Kreskey; (2) "Predictors of Trauma Reactions Following the 9/11 Terrorist Attacks," summarized by Kelly O'Connor; (3) "Cognitive Coping Styles and PTSD…

  20. 40 CFR 68.155 - Executive summary.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 15 2011-07-01 2011-07-01 false Executive summary. 68.155 Section 68.155 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.155 Executive summary. The owner or...

  1. 40 CFR 68.155 - Executive summary.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 15 2010-07-01 2010-07-01 false Executive summary. 68.155 Section 68.155 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CHEMICAL ACCIDENT PREVENTION PROVISIONS Risk Management Plan § 68.155 Executive summary. The owner or...

  2. 18 CFR 385.217 - Summary disposition (Rule 217).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Summary disposition... Filings, Notices of Tariff or Rate Examination, Orders To Show Cause, Intervention, and Summary Disposition § 385.217 Summary disposition (Rule 217). (a) Applicability. This section applies to: (1) Any...

  3. Magnetic solid phase extraction and static headspace gas chromatography-mass spectrometry method for the analysis of polycyclic aromatic hydrocarbons.

    PubMed

    Cai, Ying; Yan, Zhihong; Wang, Lijia; NguyenVan, Manh; Cai, Qingyun

    2016-01-15

    A magnetic solid phase extraction (MSPE) protocol combining a static headspace gas chromatography coupled to mass spectrometry (HS-GC-MS) method has been developed for extraction, and determination of 16 polycyclic aromatic hydrocarbons (PAHs) in drinking water samples. Magnetic nanoparticles (MNPs) were coated with 3-aminopropyltriethoxysilane and modified by cholesterol chloroformate. Transmission electron microscope, vibrating sample magnetometer, Fourier transform infrared spectrometry and X-ray photoelectron spectroscopy were used to characterize the cholesterol-functionalized sorbents, and the main parameters affecting the extraction as well as HS sampling, such as sorbent amount, extraction time, oven temperature and equilibration time have been investigated and established. Combination with HS sampling, the MSPE procedure was simple, fast and environmentally friendly, without need of any organic solvent. Method validation proved the feasibility of the developed sorbents for the quantitation of the investigated analytes at trace levels obtaining the limit of detection (S/N=3) ranging from 0.20 to 7.8 ng/L. Good values for intra and inter-day precision were obtained (RSDs ≤ 9.9%). The proposed method was successfully applied to drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Cancer Information Summaries

    Cancer.gov

    Peer-reviewed, evidence-based summaries on topics including adult and pediatric cancer treatment, supportive and palliative care, screening, prevention, genetics, and complementary and alternative medicine. References to published literature are included.

  5. 29 CFR 2570.8 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Summary decision. 2570.8 Section 2570.8 Labor Regulations Relating to Labor (Continued) EMPLOYEE BENEFITS SECURITY ADMINISTRATION, DEPARTMENT OF LABOR ADMINISTRATION... ERISA Section 502(i) § 2570.8 Summary decision. For prohibited transaction penalty proceedings, this...

  6. 29 CFR 1955.21 - Motion for a summary decision.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Motion for a summary decision. 1955.21 Section 1955.21... Summary Decisions § 1955.21 Motion for a summary decision. (a)(1) Any party may move, with or without..., within 10 days after service of the motion, serve opposing affidavits or file a cross motion for summary...

  7. 29 CFR 1955.21 - Motion for a summary decision.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Motion for a summary decision. 1955.21 Section 1955.21... Summary Decisions § 1955.21 Motion for a summary decision. (a)(1) Any party may move, with or without..., within 10 days after service of the motion, serve opposing affidavits or file a cross motion for summary...

  8. 29 CFR 1955.21 - Motion for a summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Motion for a summary decision. 1955.21 Section 1955.21... Summary Decisions § 1955.21 Motion for a summary decision. (a)(1) Any party may move, with or without..., within 10 days after service of the motion, serve opposing affidavits or file a cross motion for summary...

  9. 29 CFR 1955.21 - Motion for a summary decision.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Motion for a summary decision. 1955.21 Section 1955.21... Summary Decisions § 1955.21 Motion for a summary decision. (a)(1) Any party may move, with or without..., within 10 days after service of the motion, serve opposing affidavits or file a cross motion for summary...

  10. 29 CFR 1955.21 - Motion for a summary decision.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Motion for a summary decision. 1955.21 Section 1955.21... Summary Decisions § 1955.21 Motion for a summary decision. (a)(1) Any party may move, with or without..., within 10 days after service of the motion, serve opposing affidavits or file a cross motion for summary...

  11. ULSGEN (Uplink Summary Generator)

    NASA Technical Reports Server (NTRS)

    Wang, Y.-F.; Schrock, M.; Reeve, T.; Nguyen, K.; Smith, B.

    2014-01-01

    Uplink is an important part of spacecraft operations. Ensuring the accuracy of uplink content is essential to mission success. Before commands are radiated to the spacecraft, the command and sequence must be reviewed and verified by various teams. In most cases, this process requires collecting the command data, reviewing the data during a command conference meeting, and providing physical signatures by designated members of various teams to signify approval of the data. If commands or sequences are disapproved for some reason, the whole process must be restarted. Recording data and decision history is important for traceability reasons. Given that many steps and people are involved in this process, an easily accessible software tool for managing the process is vital to reducing human error which could result in uplinking incorrect data to the spacecraft. An uplink summary generator called ULSGEN was developed to assist this uplink content approval process. ULSGEN generates a web-based summary of uplink file content and provides an online review process. Spacecraft operations personnel view this summary as a final check before actual radiation of the uplink data. .

  12. 49 CFR 1313.2 - Contract summary filing requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 9 2010-10-01 2010-10-01 false Contract summary filing requirement. 1313.2... FOR THE TRANSPORTATION OF AGRICULTURAL PRODUCTS § 1313.2 Contract summary filing requirement. (a) Rail... promptly file with the Board a summary of each contract entered into for the transportation of agricultural...

  13. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2012-01-01

    In this column, members of the NASP Crisis Management in the Schools Interest Group provide summaries of three studies relevant to school crisis response. The first study investigated the prevalence of posttraumatic stress disorder (PTSD) among rescue workers. The second article explored the Child and Family Traumatic Stress Intervention, which is…

  14. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.; Bratica, Robyn; Dempsey, Jack R.; Karle, Jessica

    2009-01-01

    This article presents summaries of recent crisis management publications. The first article summarized provides a review of research documenting that even when children are not physically proximal to a national disaster (9/11), they may still have negative reactions. The second article summarized is an examination of the PTSD diagnostic criterion…

  15. Research Summaries

    ERIC Educational Resources Information Center

    Brock, Stephen E., Ed.

    2009-01-01

    This article presents summaries of three recent crisis management publications: (1) "The Impact of School Violence on School Personnel," summarized by Kimberly de Deaux; (2) "Children Exposed to War/Terrorism," summarized by Jennifer DeFago; and (3) "Suicide Survivors Seeking Mental Health Services," summarized by Kimberly de Deaux. The first…

  16. An improved method for the analysis of 2-aminoacetophenone in wine based on headspace solid-phase microextraction and heart-cut multidimensional gas chromatography with selective detection by tandem mass spectrometry.

    PubMed

    Schmarr, Hans-Georg; Keiser, Jutta; Krautwald, Susann

    2016-12-16

    Heart-cut multidimensional gas chromatography coupled to selective mass spectrometric detection (H/C MDGC-MS-MS) was shown to be a suitable combination for analysis of the key component for the wine off-flavor named "atypical aging off-flavor" (german: "Untypische Alterungsnote", UTA), 2-aminoacetophenone (2-AAP). Headspace solid phase microextraction (HS-SPME) was applied as an easy to automate sample preparation step suiting routine control situations. During method development two critical aspects were found, of which one is the chemical degradation of the neat substance, leading to signal reduction and a false response behavior. A second aspect is the pH stability of the deuterated isotopologue 1-(2-aminophenyl)-2,2,2-trideuterio-ethanone (2-AAP-d3) used for quantification via a stable isotope dilution assay. Despite an earlier suggestion to increase the extractable amount of 2-AAP and its isotopic standard in the headspace, alkalization of 2-AAP-d3 containing aqueous samples were found to be critical. In such a milieu a deuterium exchange can then cause erroneous quantitative results. The method proposed in our study thus uses native wine pH conditions and proved to be suitable for routine control with respect to the detection of the "atypical aging off-flavor" in wine at concentration levels below its sensory threshold of about 1μgL -1 . Good linearity was obtained in the calibrated range from 0.1-8μgL -1 (y=1,2338x+0,1029, R=0,9985) with limits of detection or quantification being 0.01 and 0.14μg/L, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. 28 CFR 68.38 - Motion for summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false Motion for summary decision. 68.38... Motion for summary decision. (a) A complainant, not fewer than thirty (30) days after receipt by respondent of the complaint, may move with or without supporting affidavits for summary decision on all or...

  18. 17 CFR 201.250 - Motion for summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 2 2010-04-01 2010-04-01 false Motion for summary disposition... PRACTICE Rules of Practice Initiation of Proceedings and Prehearing Rules § 201.250 Motion for summary... § 201.230, the respondent, or the interested division may make a motion for summary disposition of any...

  19. 31 CFR 501.727 - Motion for summary disposition.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false Motion for summary disposition. 501... REGULATIONS Trading With the Enemy Act (TWEA) Penalties § 501.727 Motion for summary disposition. (a) At any... summary disposition of any or all allegations contained in the Order Instituting Proceedings. If the...

  20. 29 CFR 2570.117 - Summary decision.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Summary decision. 2570.117 Section 2570.117 Labor Regulations Relating to Labor (Continued) EMPLOYEE BENEFITS SECURITY ADMINISTRATION, DEPARTMENT OF LABOR... ERISA Section 502(c)(6) § 2570.117 Summary decision. For 502(c)(6) civil penalty proceedings, this...